Loading...
HomeMy WebLinkAboutPermit EL18-0937 - PROLIANCE BONE & JOINT URGENT - REPLACE PANEL & LIGHTING AND INSTALL POWERPROLIANCE BONE & JOINT URGENT CARE 150 ANDOVER PARK W ELI 8-0937 Parcel No: Address: Project Name: City of Tukwila a of Department -^ Community Development — 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Kov ELECTRICAL OTC PERMIT 0223100010 Permit Number: 15OANDOVER PARK VV Issue Date: Permit Expires On: PROLIANCE BONE &JOINT URGENT CARE EL18-0937 10/26/2018 6/25/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: OPEN FRAME LLC 149DOINTERURBAN AVE 5#13OC/O JSH PROPERTIES INC, TUKWILA, WA 98168 TARASKRYSA Phone: (E23)87Z-19O5 ]2SWASHINGTON AVE S#91,KENT, WA, 98032 OLSEN ELECTRIC INC Phone: (253) 872-1905 325 WASHINGTON AVE S #91 #91, KENT, WA, 98032 OLSENEI931PE Expiration Date: 10/5/2019 '^' DESCRIPTION OF WORK: REPLACING 400 AMP DISCONNECT WITH NEW 400 AMP PANEL. REPLACING EXISTING LIGHTING WITH NEW LIGHTING. INSTALLING POWER Valuation of single family: $0.00 Valuation of mf/comm; 5130,000.00 Type of Work: TENANT IMP Fees Collected: $3,062.18 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International BuiIdin Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: 2015 2015 2015 2015 2015 National Electrical Code WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature 1/4 _Ai lAbiA I hearby certify that I have read and examined this permit and now the sam/to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. IOW Date: The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree tie conditions attached to this permit. Signature: Print Name: 1C\S-C\S kry js n Date: l/ Z/1 $ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB Parcel No: Address: Project Name: C of Tuk^ux^Ua of--,_'' Community --'-'-,_— 630DSuuthcenterQnulevamd,5ude0100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438'9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL OTC PERMIT 0223100010 Permit Number: 150 ANDOVER PARK W Issue Date: Permit Expires On: PROLIANCE BONE & JOINT URGENT CARE EL18-0937 10/26/2018 4/24/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: OPEN FRAME LLC 14900 INTERURBAN AVE S #130 C/O JSH PROPERTIES INC, TUKWILA, WA 98168 TARAS KRYSA 32SWASHINGTON AVE S#91,KENT, WA, 98032 OLSEN ELECTRIC INC 325 WASHINGTON AVE S #91 #91, KENT, WA98032 OiS[NB9]1PE ''' Phone: (523) 872-1905 Phone: (253) 872-1905 Expiration Date: 10/5/2019 DESCRIPTION OF WORK: REPLACING 400 AMP DISCONNECT WITH NEW 400 AMP PANEL REPLACING EXISTING LIGHTING WITH NEW LIGHTING. INSTALLING POWER Valuation of single family: $0.0 Valuation of mf/comm: $I30,000I0 Type of Work: TENANT IMP Fees Collected: $2,218.73 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 20172017 2015 -- — Date: | | / | . | \ | �� /� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: t� (&np Date: 11/14% This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrocal Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -1N ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB Parcel No: Address: Project Name: City of Tukwila of Deportment Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspectlon Request Line: 206'438'9350 Web site: http://www.TukwilaWA.gov ELECTRICAL OTC PERMIT 0223100010 Permit Number: 15DANDOVER PARK VV Issue Date: Permit Expires On: PROLIANCE BONE & JOINT URGENT CARE EL18-O937 10/26/2018 5/13/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: OPEN FRAME LLC 14900 INTERURBAN AVE S #130 C/O JSH PROPERTIES INC, TUKWILA, WA, 98168 TARAS KRYSA 32SWASHINGTON AVE S#91'KENT, WA, 98032 OLSEN ELECTRIC INC 3Z5WASHINGTON AVE 5#91#91, KENT, WA, 98032 ViSENE|931PE ''' Phone: (523) 872-19D5 Phone: (253) 872-1905 Expiration Date: 10/5/2019 DESCRIPTION OF WORK: REPLACING 400 AMP DISCONNECT WITH NEW 400 AMP PANEL. REPLACING EXISTING LIGHTING WITH NEW LIGHTING. INSTALLING POWER Valuation of single family: $0.00 Valuation of mf/corrim: $130000l0 Type of Work: TENANT IMP Fees Collected: $2,747.00 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International BuiIdng Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: i(t6t I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: lIVtbll`� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223100010 150 ANDOVER PARK W ELECTRICAL OTC PERMIT Project Name: PROLIANCE ORTHODONTICS Permit Number: EL18-0937 Issue Date: 10/26/2018 Permit Expires On: 4/24/2019 Owner: Name: OPEN FRAME LLC Address: 14900 INTERURBAN AVE S #130 C/O JSH PROPERTIES INC, TUKWILA, WA, 98168 Contact Person: Name: TARAS KRYSA Address: 325 WASHINGTON AVE S #91, KENT, WA, 98032 Contractor: Name: OLSEN ELECTRIC INC Address: 325 WASHINGTON AVE S #91 #91, KENT, WA, 98032 License No: OLSENEI931PE Lender: Name: Address: Phone: (523) 872-1905 Phone: (253) 872-1905 Expiration Date: 10/5/2019 DESCRIPTION OF WORK: REPLACING 400 AMP DISCONNECT WITH NEW 400 AMP PANEL. REPLACING EXISTING LIGHTING WITH NEW LIGHTING. INSTALLING POWER Valuation of single family: $0.00 Valuation of mf/comm: $130,000.00 Type of Work: TENANT IMP Fees Collected: $2,218.73 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: W41 `1 }2'i' o.,.loluf��Y r 4. Aser 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: [O/?6a This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKJ1 Community Development Deportment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. --1;cat4on Accepted: De A.polication Expires: (For of/ice ise ELECTRICAL PERM.1.. Applications and plans must be complete ir, Applications will not be accepted. atro .1_PI).1-11CATION to b: accepted for plan review. mail or by fax. "Please Pr..a."" SITE LOCATION Site Address: 150 Andover Park W Tenant Name: Proliance Orthodontics Assassor's Tax No.: Sane Number: Floor: PROPERTY OWNER Name: Proliance Orthodontics Address: 150 Andover Park W City: Tukwila State: WA CONTACT PERSON —. person reeld ail project communication Name: Taras Krysa :---'--'' . 325 Washington Ave S #91 Address: 325 Washingotn Ave S #91 13) l;72-1905 Fax: City: Kent Sia.:.\\;v:.,. Zip: 98032 Phone: (253) 872-1905 Fax: Email: tarask ctolsenelectric.ncI New Tenant: LJ Yes 1..No .ICA -L CONTRACTOR INFORMATION :I'Pa::-:. \:anle: Olsen Electric Inc. :---'--'' . 325 Washington Ave S #91 State: \VA Zip: 98032 13) l;72-1905 Fax: !. el: No.: oLsENT,-1931pE Fxp Date: 10/05/2019 . il,a .usiness License No.: 0992,32 Valuation of Project (contractor's bid price; Scope of Work (please preAT 01665 loo geOtta.66c) $2(-1(1) s 130,1101,1 InstaA :nisc. anC lighting anlp cisconnp w 1- neuu tiosn 0 plp pow/ _dew 41fr)g. 1a4c1.11;nj pduje,r. Will service be altered? LJ Yes f:,7,1 xo Type of Use: Type of work: El New I] Low Voltage :7 Gene: >r Property Served by: El Puget Sound Energy SL'atzle City Lig:: ',re A WnPennii Curacr1Applications-Handauu • .)Fs y -aau 17 • r,p7 • • Re N Ise& January 2017 bh :ureihan 50 amps? Yes hia No il'asatudel T;:mant Improvement ieiiporary Service Page 1 of 2 RESIDENilL'iL NEW RESIDENTIAL SERVICE O New single family dwellings Sif 5.9 (including an ahaerie( garagc, Ej Garages, pools, spas and o.Thui1C1p,,- SS3.54 Ej Low voltage systems (alarm, furnace il-...../rnestaIl S61.05 RESIDENTIAL REVIDLEL AN.l; SERVIlCE CHAI15GES O Service change or alte.t.tic.1 (no added/altered .?irenits) • Service change with acaecl-altereti .c:its number caed cir S.2.00 at, O Circuits added/altercd , se.: = i.i. .1.5 (up to 5 circuits'. 0 Circuits added/alteree vtifiaut cht'..aze S55.65 (6 or more circai '7.65 ea Meter/mast repair 55 O Low voltage systems Sr ..6f (alarm, furnace tm..-rn"..)stat) CAULTI-FAMILY AND COMMERCIAL aro ed on the valuation of the electrical contract. MISCELLANEOUS FEES stir\ ice (resabemia,) S66.30 'irary service (generator) S82.52 lelitt.„:hcturedintobile home service $87.98 cxciticlimi garage :)1: S82.21 Number of concessions S11.02 ea Each ride and generator truck SI 1.02 ea ***EFFECTIVE JANUARY I, 20 4 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATMN Value of Construction — in all oases, a to possible revision by the Perm.tCenio- cale ::Soonsjuctic, aooinsofau55 -eci Oac applicant. This figure will be reviewed and is subject co.-m-ily'vah an - cent feo smEedules. Expiration of Plan Review -- iii2plications for NA hion no per.bit 15.ssmoa The Building Official may ioan s: one of lira:: for at, ac c;. m_mieo andjustifiable cause demons.ratad, tile date of application shall expire by limitation. 96 clays. The extension srlaii oe requested in writing I HEREBY CERTIFY THAT I H 55 90A !') 'ND 05<T". E:1 55515 .551 1555 1 5< AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 3Y THE -LAW S (-:-F THE STA.:P.(r '2s,!; ALTHORIZEE TO APPLY FOR THIS PERMIT. BUILDING OWNER OR CT R 55. CC.,:CTIZACF, Signature: Print Name: Taras Ksysa Mailing Address: 325 #9! .ess J15 Avirirwar 4 W: Permit Cover ApplicationN-Flanr,o,:s 2plicruc, i1 Re‘ Ise& January 2017 bh Date: C/26/2018 Saicphone:253) 87255905 S:a.0 Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $315.18 EL18-0937 Address: 150 ANDOVER PARK W Apn: 0223100010 $315.18 Credit Card Fee $9.18 Credit Card Fee R000.369.908.00.00 0.00 $9.18 DEVELOPMENT $306.00 PERMIT REINSPECT FEE - AFTER HRS INSP FEE TOTAL FEES PAID BY RECEIPT: R16185 R000.359.000.00.01 0.00 $306.00 $315.18 Date Paid: Wednesday, December 19, 2018 Paid By: TARAS KRYSA Pay Method: CREDIT CARD 040565 Printed: Wednesday, December 19, 2018 3:16 PM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 12/19/2018 03:16:16 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********0376 K TRAN AMOUNT: $315.18 APPROVAL CD: 040565 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://c lassie .convergepay .comNirtualMerchant/transaction.do?dispatchMethod=prinffr... 12/19/2018 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $528.27 EL18-0937 Address: 150 ANDOVER PARK W Apn: 0223100010 $528.27 Credit Card Fee $15.39 Credit Card Fee R000.369.908.00.00 0.00 $15.39 ELECTRICAL $512.88 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15857 R000.345.832.00.00 0.00 $512.88 $528.27 Date Paid: Friday, November 16, 2018 Paid By: RYAN SWIGART Pay Method: CREDIT CARD 092367 Printed: Friday, November 16, 2018 12:39 PM 1 of 1 SYSTEMS e CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/16/2018 12:39:17 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: ******'***2019 K TRAN AMOUNT: $528.27 APPROVAL CD: 092367 RECORD #: 000 CLERK ID: Rachel_e X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 11/16/2018 Page 2 of 2 *mire CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/16/2018 12:39:17 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********2019 K TRAN AMOUNT: $528.27 APPROVAL CD: 092367 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy haps ://c lassi c.convergepay .c om/VirtualMerehant/transaction. do?di spatchMetho d=printTr... 11 /1 6/20 1 8 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,218.73 EL18-0937 Address: 150 ANDOVER PARK W Apn: 0223100010 $2,218.73 Credit Card Fee $64.62 Credit Card Fee R000.369.908.00.00 I 0.00 $64.62 ELECTRICAL $2,051.53 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 I 0.00 $2,051.53 TECHNOLOGY FEE $102.58 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15728 R000.322.900.04.00 0.00 $102.58 $2,218.73 Date Paid: Friday, October 26, 2018 Paid By: TARAS KRYSA Pay Method: CREDIT CARD 026051 Printed: Friday, October 26, 2018 3:25 PM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 10/26/2018 03:25:24 PM CREDIT CARD SALE VISA CARD NUMBER: **********1706 K TRAN AMOUNT: $2,218.73 APPROVAL CD: 026051 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 10/26/2018 Date: CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 10/26/2018 03:25:24 PM CREDIT CARD SALE VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: **********1706 $2,218.73 026051 000 Rachelle Thank you! Customer Copy K Page 2 of 2 https://classic.convergepay.cornNirtualMerchantitransaetion.do?dispatchMethod=printTr... 10/26/2018 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: �f�[.�rjA'�V !1(J Type of Inspection: y N Address: /[ /�� (1,`� n 1 Date Called: Special Instructions: Date Wanted: l (07 . Requester: r� Tit-4- Phone- Phone No: 2€40ill 2,c73 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: afx&-.<.651-0,45' rdA, Inspector.i tk- Date: O r(o ir 7 E REINSPECTION FEE REQUIRED. Prior to next inspection. fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit tlA 73 7 INSPE TION NO, PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: Row foicdti Typ t- Inspectipn: 1 tv i7K- Address: 16,0 kpv j Date Called: ARticAlotis : Special Instructions: Date Wanted: 3 a. . Requester: — _ Phone No: pproved per applicable codes. IgCorrections required prior to approval. OMMENTS: . galaif a 621 c --1--c---- i7K- DX, , srexxls-f-A0 ARticAlotis : Peet -re ert 5-0 70 6 7 e,Lavvr cfreki wt.( cpAiDAJGroo 14 epdb.kr-- - 0.1PLPr6 LA -00 itia 114-6rtt_. sco6o4L. 6, - aCtr-/trt - LA -4, 0<-1--• — _ Inspector: 1 1 Date: t9 REINSPECTIONFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call. to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit tel4t 37 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: kr Type of Inspection: Vvlir AI Address: 15-0 gal Date Called: Special Instructions: Date Wanted: Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: cet f 4(cPr t -P tAlfisinnik 02ri4p O Inspector: 11. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. z INSPECTION NO. INSPECTION RECORD Retain a copy with permit 64-0131 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: of Inspection: Type)Address: / /5.-0 ,4-PIA) Date Called: Special Instructions: Date Wanted:p a. . . . Requester: . Phone No: KAA4—tf gt6it-144S Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Approved per applicable codes. 0 Corrections required prior to approval. MMENTS: ij 5—Pare . KAA4—tf gt6it-144S JO X Ad. 46 , X- Kk`FIIS 6 tc co X Xit'i .2-0E V 1 Poole Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 A Ai (206) 431-3670 Project: f) r ro 1(41, CC Type of Inspection: Address: r Date Called: Aryl fri A . Special Instructions: Date Wanted: a.m. p.m. 'Requester: Phone No: Ap roved per applicable codes. OCorrections required prior to approval. COMMENTS: IA0 Eta CO Li e, -(or- t -N CfLCJ rii e c Gt.ivAiL 1-11 Inspector: \ Date:it //(4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. OFF HOURS INSPECTION Reimbursement authorizarovo/Cocunduct/nxynctionocdvitkesdbrinBo0'houcs Date: \/}/K�/\^� `~ ~-/ � ` Requested By: 7k...13-\ 6- Firm/Company: C)\=e \prlrk` 7/lr. Permit Number: ��` �/�� v R7 Inspection Information Project Name: Tl Cc/Ce, Project Address/Location: \`=)0 (\^^e'� \l""\� h� Requested Date for Inspection: \CO:2\/11 Contact Name: Requested Time: C;c) PM Special Conditions for Consideration: ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $102.00 per hour (minimum total of $006.O0). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice wiH be issued for aH irispection time in excess ofthree (3) hours. . Signature: ~-- Date: 10/K� «� Printed Name: ^7 \' k RECEIVEU CITY OF TUKWIL4 ncr 9 2018 city use Only: Approved: Disapproved: PERMIT CENTER Paid: Receipt No: Date of Approval/Disapproval: Remarks: Authorized Reviewer: wAPermit Hours Inspection 1-2mdocx Fault Load Calculation Form 400A CT CAN (10-25-18) Step A: Transformer Information Step 1: KVA > 300 3 Phase Step 2: Volts > 277 Step 3: AIC > 17200 (Refer to chart or AIC) Ohms Step 4: Total Ohms > 0.016104651 Step B: Distance and Wire Size Step 5: Wire Size > 600 AL AL OR CU REVIEWED FOR COMPLIANCE WITH NFPA70-NEC NOV 13 2018 Step 6: Length of Wire Run > 80 Feet Step 7: Impedance -----------> 0.036 Step 8: Number of Wire Runs ---> 3 Step 9: Ohms 0.00096 -------------------> Step 10: Total Ohms ----> 0.017064651 Step 11: AIC > 16232.38573 City ofTukwita BUILDING DIVISION REVISION N0:! RECEIVED CITY OF TUKWILA NUV 01 201d PERMIT CENTER aiA- ocya Fault Load Calculation Form Panel H1 (10-25-18) Step A: Transformer Information Step 1: KVA > 3 Phase Step 2: Volts > 277 Step 3: AIC 16232 (Refer to chart or AIC) > Step 4: Total Ohms -----> 0.017065057 Ohms Step B: Distance and Wire Size Step 5: Wire Size > 3/0 CU AL OR CU Step 6: Length of Wire Run --- > 5 Feet Step 7: Impedance > 0.077 Step 8: Number of Wire Runs > 2 Step 9: Ohms ----- ----> 0.0001925 Step 10: Total Ohms 0.017257557 ---------> Step 11: AIC > 16050.93961 Fault Load Calculation Form 300KVA 120/208v XFMR (10-25-18) Step A: Transformer Information Step 1: KVA > 3 Phase Step 2: Volts> 277 Step 3: AIC 16050 (Refer to chart or AIC) > Step 4: Total Ohms > 0.017258567 Ohms Step B: Distance and Wire Size Step 5: Wire Size > 3/0 CU AL OR CU Step 6: Length of Wire Run ------> 5 Feet Step 7: Impedance > 0.077 Step 8: Number of Wire Runs > 2 Step 9: Ohms > 0.0001925 Step 10: Total Ohms 0.017451067 ---> Step 11: AIC > 15872.95495 Fault Load Calculation Form MDP Disconnect (10-25-18) Step A: Transformer Information Step 1: INA —> Step 2: Volts > 120 3 Phase Step 3: AIC > 15872 (Refer to chart or AIC) Step 4: Total Ohms ---- -> 0.007560484 Ohms Step B: Distance and Wire Size Step 5: Wire Size Step 6: Length of Wire Run Step 7: Impedance > 300 CU > 5 Feet > 4 Step 8: Number of Wire Runs --> Step 9: Ohms Step 10: Total Ohms > 0.006666667 > 0.014227151 Step 11: AIC > 8434.577232 AL OR CU Fault Load Calculation Form 800A MDP (10-25-18) Step A: Transformer Information Step 1: KVA > 3 Phase Step 2: Volts > 120 Step 3: AIC > 15872 (Refer to chart or AIC) Step 4: Total Ohms -------------> 0.007560484 Ohms Step B: Distance and Wire Size Step 5: Wire Size ---_ ---> 300 CU AL OR CU Step 6: Length of Wire Run > 5 Feet Step 7: Impedance ----- > 4 Step 8: Number of Wire Runs —> 3 Step 9: Ohms > 0.006666667 Step 10: Total Ohms > 0.014227151 Step 11: AJC -------_— > 8434.577232 Fault Load Calculation Form Panel KP1 (10-25-18) Step A: Transformer Information Step 1: KVA > 3 Phase Step 2: Volts> 120 Step 3: AIC8020 (Refer to chart or AIC) > Step 4: Total Ohms > 0.014962594 Ohms Step B: Distance and Wire Size Step 5: Wire Size > #1 CU AL OR CU Step 6: Length Wire Run > 10 Feet of Step 7: Impedance > 0.16 Step 8: Number of Wire Runs > 1 Step 9: Ohms > 0.0016 Step 10: Total Ohms-----------------> 0.016562594 Step 11: AIC > 7245.24211 Fault Load Calculation Form Panel KP2 (10-25-18) Step A: Transformer Information Step 1: KVA > 3 Phase Step 2: Volts > 120 Step 3: AIC ----- > 8020 (Refer to chart or AIC) Step 4: Total Ohms > 0.014962594 Ohms Step B: Distance and Wire Size Step 5: Wire Size > #1 CU AL OR CU Step 6: Length of Wire Run --------> 10 Feet Step 7: Impedance > 0.16 Step 8: Number of Wire Runs > 1 Step 9: Ohms ---- > 0.0016 Step 10: Total Ohms --- > 0.016562594 Step 11: AIC > 7245.24211 Fault Load Calculation Form Panel LP1 (10-25-18) Step A: Transformer Information Step 1: KVA 3 Phase ----> Step 2: Volts > 120 Step 3: AIC > 8020 (Refer to chart or AIC) Step 4: Total Ohms -------------> 0.014962594 Ohms Step B: Distance and Wire Size Step 5: Wire Size ----- > #110 CU AL OR CU Step 6: Length of Wire Run > 10 Feet Step 7: Impedance > 0.12 Step 8: Number of Wire Runs > 1 Step 9: Ohms > 0.0012 Step 10: Total Ohms > 0.016162594 Step 11: AIC > 7424.551009 Lighting Summary LTG -SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: Proliance Orthodontics Tukwila Date 10/25/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use Company Name: Olsen Electric Company Address: 325 Washington Ave S #91, Kent Wa 98032 Applicant Name: Ryan Swigart Applicant Phone: 253-872-1905 Applicant Email: Tarask@olsenelectric.net Project Description E New Building ] Addition 2 Alteration No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting Description System Included New LED fixtures controlled by occupancey sensors. Interior Lighting Plans Interior Lighting Power Allowance Method J Building Area Method ❑ Space -by -space Method Select method used in project. Interior Lighting Controls Exception 5 Luminaire Level Controls (LLLC) interior lighting power shall comply with the 1 All C405.2.1 - C405.2.8 Lighting Controls E C405.2 Lighting Additional Efficiency Package Option C406.4 Enhanced Digital Lighting Controls To comply with C406.4, no less than 90% of the total installed required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: ( No Dwelling 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units 0C406.3 High Efficacy Lighting ] R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Description U Exterior Lighting Plans Included Existing wall packs/ sofit can lights controlled by astronomical time clock Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project ] ] Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing -to -remain Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT For exterior lighting projects, include new + existing -to -remain Proposed Tradable and Proposed Non -Tradable Lighting Wattage ,i 7 interior lighting fixture wattage in -SPACE form. exterior lighting fixture wattage in tables in LTG -EXT form. Lighting Summary, c' LTG -SUM 2d15 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Proliance Orthodontics Tukwila Date 10/25/2018 Change of Space Use — Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replacedain others, then providerre lighting pe compliance separateforms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. ❑ No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced ] ] Less than 50% of existing are replaced [ ❑ - Lamp and/or ballast replacement only - existing total wattage not increased ] E - - - - -- - - - 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage New wiring installed to serve added Exterior lighting E. ❑ — fixtures and/or fixtures relocated to new — circuit(s) New or moved lighting panel ❑ _ Interior space is reconfigured - luminaires unchanged or relocated New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Interior Lighting - Bu!ding Area Method LTG -INT -BLD 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R Revised Nov 2017 Project Title: Proliance Orthodontics Tukwila Date 10/25/2018 Calculation Area NOTE 9 0 New Construction Q Addition - O Addition stand alone + existing O Spaces where < 50% of Spaces where Z 50% of Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) For Building Department Use LPA Calculation Type 0 Standard @ Additional Efficiency Package Option O C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note LED 2x4 Troffer Maximum Allowed Lighting WattageN0TE 1 Building Area Location (plan #, room #, or ALL) Area Description Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) NOTE 2 Health care clinic All Orthodontics Office 6455 0.70 4519 7 98 Health care clinic All Exterior LED Down Light 6 13 78 Health care clinic All Recessed LED Can Light 29 Total 6455 Health care clinic Proposed Lighting Wattage Building Area Location (plan #, room #) Fixture Description NOTE 3, 4, 5, 8 Number of Fixtures Watts per Fixture NOTE 7 Watts Proposed Health care clinic All LED 2x4 Troffer 35 32 1120 Health care clinic All LED 2x2 Troffer 9 32 288 Health care clinic All Recessed LED Strip Light 14 7 98 Health care clinic All Exterior LED Down Light 6 13 78 Health care clinic All Recessed LED Can Light 29 13 377 Health care clinic All Recessed LED Wall Wash Light 3 13 39 Health care clinic All Surface Mount 18" Fixture 5 12 60 Health care clinic All 9" Pedant Fixture 6 6 36 Health care clinic All Restroom Wall Sconce 4 12 48 Health care clinic All LED Vanity Light 1 14 14 Health care clinic All LED Shop Lights 2 29 58 Compliance by Building Area NOTE 8 Building Area Wamings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Health care clinic Confirm all fixtures are reported under proposed lighting - low watts relative to maximum allowed. 4519 2216 COMPLIES C406.3 Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the Totals project scope. Select building area category from drop down menu. Note 2 - Unlit Message - Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 3 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage hnhannn Qnil,hnn Aron {,inn. io nn{ nllnuanrl nnrinr {hn DI ilrlinn Aro. AAA{hnrl nmmnlinnro n.{, 4519 2216 /.1Clwaan Dunuury Maid rypCb w nU NCU UWIWI 111C ounurny Maid rvrawuu UU1IIpudII( pd Note 9 Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Building Area types and gross interior areas. Bill Rambo From: Sent: To: Subject: Rachelle Ripley Wednesday, October 31, 2018 3:50 PM Bill Rambo FW: Proliance Orthodontics Permit This customer was issued an OTC electrical. The scope of work is more than they had listed on the application so they are going to bring plans in tomorrow for Jim for review. Rachelle Ripley Permit Technician 1 City of Tukwila 6300 Southceiiter BI, Suite 100 Tukwila, WA 98188 T: 2064}}.7165| F: 206431.3665 From: Jim Benner <Jim.BennerTukwiIaWA.gov> Sent: Wednesday, October 31, 2018 3:20 PM To: Rache||eRipley <Rache||e.R|p|ey@Tukwi|aVVA.gov> Subject: RE: Proiiance Orthodontics Permit Just talked to them. They'll be submitting plans tomorrow under issued permit number. From: Rache||eRipley <RacheUe.R|nleY@Tukvv|a\NA.gov> Sent: Wednesday, October 31, 2018 2:56 PM To: Jim Benner <Jim.BennerTukwiIaWA.gov> Subject: RE: Proliance Orthodontics Permit Well shoot! Rachelle Ripley Permit Technician 1 City of Tukwila 630oSoutbcenterBl, Suite /w|Tukwila, WA 98180 T: 2o6433.7165| F: 20643/.3665 From: Jim Benner <Jim.Benner@TukwilaWA.gov> Sent: Wednesday, October 31, 2018 2:25 PM To: Rachelle Ripley <Rachelle.Riplev@TukwilaWA.gov> Subject: RE: Proliance Orthodontics Permit This goes a little beyond the original "replacing 400 amp switch". Plan review required. From: Rache||eRipley «RacheUe.Rip|ey4DTukwi|aVVA.gov» Sent: Tuesday, October 30, 2018 4:13 PM To: Jim Benner <Jim.Benner@TukwiIaWA.gov> Subject: FW: Proliance Orthodontics Permit Hi Jim, RECEIVED CITY OF TUKWILA. NOV 0 1 2018 PERMIT CENTER 1 talked to them today and they sent in this email. 1 just want to confirm that you do not need plan review. RacheYle Ripley Permit Technician City of Tukwila 63ooSoutb,cntcrBl, Suite 100 | Tukwila, WA 98188 T: 2064337165| F: 206431.3665 From: VVynetta8ivens<VVynetta.Bivens@Tuhwi|aVVA.gmv> Sent: TuesdayOctober 30, 2018 3:58 PM To: RacheUeRipley <RacheUe.Rip|eyVDTukwi|aVVA.goup Subject: FW: Proliance Orthodontics Permit HiRache|k� Please respond. Thanks! Wynetta From: Taras Krysa <tarask@olsenelectric.net> Sent: Tuesday, October 30, 2018 2:33 PM To: VVynettaBivens<VVynetto.Bivens@Tukvx|aVV4.gnv> Cc:radk@o|sene|ectric.net Subject: FW: Proliance Orthodontics Permit Good Afternoon, 1 spoke with Rachel today about the projectject below and she conformed we won't need plan review. Can you please respond to this email so we have it in writing in case it comes up later during inspections. Thanks, Taras Taras Krysa Olsen Electric Inc. [):253'872'1905 F:253'269'0268 tarask@olsenelectric.net From: Taras Krysa <tarask@olsenelectric.net> Sent: Monday, October 29, 2018 2:41 PM To: 'P|anning@tukvvi|ovva.gov'<P|anninA@tukmi|avva.Aov> Subject: Proliance Orthodontics Permit Good Afternoon, We have a permit #EL18-0937, site address 150 Andover Park W. We were given it as an over the counter permit but I just wanted to make sure that it wasn't supposed to go through plan review? It is a healthcare facility. The scope of work is replacing a 400amp disconnect with a new 400amp panel. We are installing new lighting and new misc. power. Attached is the permit we received and the plans for reference. 2 Thanks, Taras Taras Krysa Olsen Electric Inc. O:253'872'19O5 F:253-269'0268 tarask@olsenelectric.net CAUTION: This email o''matedfnornoutsidetheCitvofTukvv|ane1vvork.PleaseDOy0OTopenattachn1entsordick links from anunknown orsuspicious origin. 3 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0937 DATE: 11/01/18 PROJECT NAME: PROLIANCE BONE & JOINT URGENT CARE SITE ADDRESS: 150 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS 10 ft? itIlL Building Division III Public Works ❑ Fire Prevention Structural PIanning Division ❑ Permit Coordinator r PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/06/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/04/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: oa o,vki Plan Check/Permit Number: E LV ' ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # • Revision # I after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Project Address: Contact Person: Vk-01\cti rc' L\c p)- cco-P 1-50 Al)dClEC- PCC \ Summary of Revision: Phone Number: l igoS AACVnii 1c>W uc \-\ i Il l -c-c- V re C \Clfm Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W \Fonar Center \ Templates \ Forms \Revision Submittal Form doc Revised August 2015 Date: City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. 11 (6 Plan Check/Permit Number: ELI S- .o37 ❑ Response to Incomplete Letter # O Response to Correction Letter # [N- Revision # ` after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: Project Address: I sz) /4 r Contact Person: oma,P Uvpd %r -e' C) U -e v �G'l ✓ c k) Summary of Revision: -Plov, Phone Number: 5)-3 - 8 7 rZ - I (QS re V 1 e ✓, ED r(TY OF T�1F��11/16Ii PERMIT -ENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 1:3--1 Entered in TRAKiT on 1[--- ('"( WAPermn Center\Ternplates\Forms\Revision Submittal Formdoc Revised. August 2015 OLSEN ELECTRIC INC Aft k Washington State Department of / Labor & Industries 1 lora e Espanol Contact rSearch L&I Safety & Health Claims & Insurance Page 1 oaf 4 AZ [ride.< Help My 1.&1 Workplace Rights Trades & Licensing OLSEN ELECTRIC INC Owner or tradesperson Principals OLSEN, ERIC S, PRESIDENT OLSEN, ERIC S, AGENT Doing business as OLSEN ELECTRIC INC WA UBI No. 602 696 333 325 WASHINGTON AVE $ #91 KENT, WA 98032 253-872-1905 KING County Business type Corporation License Verify the contractoes active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. OLSENEI931PE Effective — expiration 10/05/2007— 10/05/2019 Designated administrator OLSEN, ERIC S License type Electrical Administrator Bond CBIC Bond account no. 514815 Active. Meets current requirements. License no. OLSENES9610H $4,000.00 Received by L&I Effective date 12/28/2009 01/24/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EFRBRO0308 Issue date 11/03/2017 Violation city KENT Type of violation Satisfied RCW/WAC 19.28.161 RCW Violation amount $500.00 Help us improve https://securelni.wa.gov/verify/Detail.aspx?UBI=602696333&LIC=OLSENEI931PE&SAW= 10/26/2018 OLSEN ELECTRIC INC ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an improper ratio. Infraction no. EROJE01023 Issue date 04/19/2017 Violation city KENT Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication Installation or alteration as referenced in WAC 296-46B-901. Infraction no. EJACH00949 Issue date 08/02/2016 Violation city KENT Type of violation ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an Improper ratio. Employed Vladislav Kurkov to install branch circuits in a commercial dwelling structure without proper journeyman supervision. Infraction no. EJACH00948 Issue date 08/02/2016 Violation city KENT Type of violation ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an improper ratio. Employed David Gonzales to Install branch circuits in a commercial dwelling structure without proper journeyman supervision. Infraction no. EJACH00947 Issue date 08/02/2016 Violation city KENT Type of violation ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an improper ratio. Employed Stephen Adamson to install branch circuits In a commercial Satisfied ...................... RCW/WAC 19.28.101 RCW Violation amount $250.00 Satisfied ... _................. RCW/WAC 19.28.161 RCW Violation amount $500.00 Satisfied .......................... RC W/VVAC 19.28.161 RCW Violation amount $500.00 Satisfied _....................... RCWNVAC 19.28.161 RCW Violation amount $500.00 Page 2 of 4 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602696333&LIC=OLSENEI931 PE&SAW= 10/26/2018 OLSEN ELECTRIC INC dwelling structure without properjourney supervision. Infraction no. EJACH00946 Issue date 08/02/2016 Violation city KENT Type of violation ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an improper ratio. Employed Ian Egan to install branch circuits in a commercial dwelling structure without proper journeyman supervision. Infraction no, ELY0D01098 Issue date 07/08/2016 Violation city KENT Type of violation ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an improper ratio. JORDAN BERENS, PABLO KOZELO, RICHARD KERN Infraction no. EBOES00755 Issue date 01/10/2013 Violation city ENUMCLAW Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296 -46B -900(10)(a), effective after 12/30/2008 see WAC 296 -46B -901(10)(a). Satisfied RCW/WAC 19.28.161 RCW Violation amount $500.00 Satisfied RCVV/VVAC 19.28.161 RCW Violation amount $250.00 Satisfied RCW/WAC 19.28,101 RCW Violation amount $250.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 143,972-00 Doing business as OLSEN ELECTRIC INC Estimated workers reported Quarter 2 of Year 2018 "51 to 75 Workers" L&I account contact T3 / STEPHANIE HENDERSON (360)902-5598 - Email: HSTE235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Page 3 of 4 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602696333&LIC=OLSENEI931PE&SAW= 10/26/2018 OLSEN ELECTRIC INC Contractor Strikes ............................................_........ No strikes have been issued against this coh....tor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 12/15/2014 Inspection no. 317616217 Location Emmanuel Bible Fellowship Olympia, WA 98506 Violations Page 4 of 4 0 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602696333&LIC=OLSENEI931 PE&SAW= 10/26/2018 LSEN LECTRIC INC. 150 ANDOVER PARK W TUKWILA, WA 98188 REVISIONS No changes shaq rn,,IdO to thr4 scoof= of work withoht approval nf Tukwila 81.10c.lino Division NOTE: Revisions will require a 11P.N Wan subnpitai and may include additional pin re,!,ryf fes FILE CZ:.,77 Permit Mo. l'Ic6/D°121 OWNER PROLIANCE ORTHODONTICS 1500 ANDOVER PARK WEST TUKWILA, WA GENERAL CONTRACTOR FERRIS-TURICEY GENERAL CONTRACTORS P.O. COX 31109 SEATTLE, WA 98103 VICINITY MAP Ntetootirler et. .„.,,,efeeseeitsemese:ttlf* ' 4 r I r • 1: N. oto omo, Not litettreeee eteeeNN teeetotteeptepeifik ortotwedetetotegoie „ 1 ION, DRAWING INDEX El E2 E3 E4 COVER PAGE POWER PLAN LIGHTING PLAN PANEL SCHEDULES/ RISER DIAGRAM GENERAL NOTES ALL FIELD WORK MUST BE PER SPEC UNLESS OTHERWISE INFORMED AS-BUILTS REQUIRED JOURNEYMAN OLSEN ELECTRIC CONTACT: RAD KRYSA PHONE: (253) 872-1905 Plan review approval is subject to errors crld cm!cte!cins. Approval of constructlon documents dcec the violation of any adopted c0 cr caLl:ries. 1 -ft of approved Field Copy and conditions b By: Date: City of Tukaa BUILDING DIVISION Symbols Abbreviations General Symbols Revision Identifier Revision Identifier Revision Flag Mech Equip Designated: Top Half Indicates Type of Equip; Bottom Half Indicates Equip Number. Lighting Fixture Type Circuit Symbols Circuit Concealed In Ceiling or Wall, Power Circuit Concealed In Floor or Underground /rTh L1-3(8) 110 Circuit Home Run (Panel -Circuit (Building)) Large Mark Indicates Neutral, Short Mark Indicates Phase Or Switchleg, #12 AWG UON Sealtite Flexible Conduit Circuit Turning Up Circuit Turning Down Circuit Stub Up/Out Circuit Continuation Feeder, Circuit or Home Run VVithin 2 Hour Assembly Junction Box Proposed Heat Trace Routing. Verify Heat Trace Connection Locations And Requirements Prior To Rough -n. Lighting Symbols —0-1 Shaded Circle Or Comer Indicates Pathway Lighting Fixture. Applies To All Fixture Types. Fluorescent 2x4 Lighting Fixture, Recessed Or Lay In. Fluorescent 1x4 Lighting Fixture, Recessed Or Lay In. Strip Fluorescent Fixture (Surface Of Chain Mounted) Ceiling Mounted Lighting Fixture. Surface, Recessed, Or Pendant. See Lighting Fixture Schedule. Wall Mounted Fixture. See Fixture Schedule. Self Contained Emergency Lighting Fixture. Exit Sign, Surface Wall Mounted, Universal Mounted. Directional Arrow(s) As Indicated. O Exit Sign, Ceiling Mounted, Universal Mounted. Directional Arrow(s) As Indicated. Light Fixture Circuit Number Or Switch Leg. of– Light Fixture Type. See Light Fixture Schedule. XX Light Fixture • Dimmer O Switch Single Pote; Smaller Letter Indicates Fixture With Same Letter In Room Shall Be Connected To Switch, Switch, 3 Way Switch, 4 Way Switch Motor Rated Toggle Lighting Control Panel Photo Cell Wall Mtd. Fluorescent Fixture Wall Mtd. Incandescent Fixture Surface Mtd. Fluorescent Fixture Pendant Undercabinet Fluorescent Fixture Track Lighting Power Symbols (13:1 Duplex Receptacle GFCI - Ground Fault Circuit Interrupter T- Timer 1 (2) Duplex Receptacle GFCI - Ground Fault Circuit Interrupter • Dedicated Duplex Receptacle ei Duplex Receptacle (Above Counter) 0.1 Receptacle (208V. 1 , AMP as Indicated) +44" Distance From Finished Floor To Center Of Device. Equipment Connection 4J Hand Dryer Connection ® Transformer For IR Faucet Power (By E.C.) DDC Connection - Provide (2) 120V 20 Amp DDC Circuits ati 208Y/120V Panel Board 030 Combination Magnetic Motor Starter With Disconnect Switch And Fusing As Required Disconnect Grounding Meter Exhaust Fan Panel Board Communication Symbols CD El Combination Tete/Data Outlet Telephone Outlet Data Cable Outlet Card Reader Magnetic Door Holder Door Contact Camera Intercom Wireless Antenna NOTE: Not all of the above information is incorporated in the drawings, Lighting and Power spec sheets have there own legend. NC A (Amp) AC ADJ ADJT AFF AHJ AIC ALT ANN ARCH ASCC AUTO AUX AWG BKBD BKR BLDG CAP CB CF CFM CKT CLG CLR COL COM COMM CPS CT CTL CU CUH Air Conditioning(er) Ampere Above Counter, Altemating Current Adjustable Adjacent Above Finished Floor Local Authority Having Jurisdiction Amperes Interrupting Capacity Alternative Annunciator Architect; Architectural Available Short Circuit Current Automatic Auxiliary American Wire Guage Backboard Breaker Building Conduit Capacity Circuit Breaker Cubic Feet Cubic Feet Per Minute Circuit Ceiling Clear Column Common Communication Cycles Per Second Current Transformer Control Copper Cabinet Unit Heater DC Direct Current DG Dedicated Ground DISC SW Disconnect Switch DISC Disconnect DN Down DWG Drawing EC EDH EF EGC EL ELEC ELEV EM EMD EMT ENCL ENTR EP EPO EQUIP** EWC EWH EXH EXT EXIST Exist, East Electrical Contactor Electric Duct Heater Exhaust Fan Equipment Ground Conductor Elevation Electric(al) Elevator Emergency Estimated Maximum Demand Electrical Metallic Tubing Enclosure Entrance Explosion Proof Emergency Power Off Equipment Electrical Water Cooler Electrical Water Heater Exhaust Exterior Existing F Fahrenheit FA Fire Alarm FAA Fire Alarm Annunciator FAP Fire Alarm Panel FC Foot Candle FCU Fan Coil Unit FD Fire Damper FDR Feeder FIXT Fixture FLA Full Load Amps FLEX Flexible H Height HID High Intensity Discharge HOA Hand Off Automatic HOR Horizontal HP Horsepower HPS High Pressure Sodium HR Hour HT Height HW Hot Water HWC Hot Water Circulation HWR Hot Water Return HWS Hot Water Supply HZ Hertz IC Intercom IES Illuminating Engineers Society IG Isolated Ground IMC Intermediate Metal Conduit IN Inch JB Junction Box KV Kilovolt KVA Kilovolt Amperes KVAR Kilovolt Amperes Reactive KW Kilowatt KWH Kilowatt Hour LBS Pounds LCC Lighting Control Cabinet LRA Locked Rotor Amps LT Light LTG Lighting LV Low Volt MAG Magnetic MAN Manual MAT Material MAX Maximum MCA Minimum Circuit Amps MCB Main Circuit Breakers MCM Thousand Circular Mills MD Motorized Damper MECH Mechanical MEZZ Mezzanine MG Motor Generator MH Metal Halide MIN Minimum MISC Miscellaneous MLO Main Lug Only MOCP Maximum Overcurrent Protection MS Magnetic Starter MTD Mounted MTG Mounting MTR Motor MV Mercury Vapor N North; Neutral N/A Not Applicable NC Normally Closed NEC National Electric Code NEMA National Electric Manufactures Association NESC National Electric Safety Code NEUT Neutral NFPA National Fire ProteCtion Agency NIC Not In Contract NO Normally Open NTS Not to Scale OC On Center OFCI Owner Furnished Contractor Installed OFF Office OFOI Owner Furnished Owner Installed OHP Overhead Power OHT Overhead Telephone OL Overload FOIC Furnished By Owner, Installed By Contractor P Primary FS Follow Switch PA Public Address FSD Fire/Smoke Damper PAR Parallel FVNR Full Voltage Non -Reversing PB Pull Box FVR Full Voltage Reversing PE Photo Electric PF Power Factor Generator PH Phase Ground Fault Circuit Interrupter PIV Post Indicator Valve Ground Fault Relay GEN GFCI GFR PNL POC PSE PWR Q SC SCD SCL SD SECT SF SHT SPEC SPL SQ STOR SW SWBD SYM SYS TB TC TEL TV TVSS TYP UBC UFC UG UGE UGT UH UL UV V VAV VEL VFD VM VOL W W/ W/O WH WHM WP X XFMR XMTR 1E: Panel Point of Connection Puget Sound Energy Power Quanity R Raceway, Resistance RAD (R) Radius RECPT Receptacle REF Refrigerator RLA Running Load Amps RPM Revolutions Per Minute South Security Smoke Control Damper Seattle City Light Smoke Detector Section Supply Fan Sheet Specification Special Square Storage Switch Switchboard Symmetrical System Thermostat Terminal Box Time Clock Telephone Telephone Transient Voltage Surge Suppression Typical Uniform Building Code Uniform Fire Code Underground Underground Electrical Underground Telephone Unit Heater Underwriters Laboratories Unit Ventilator Volt Variable Air Volume Velocity Variable Frequency Drive Voltmeter Volume Watt, West VVith Without Water Heater Watthour Meter Weatherproof Reactive Transformer Transmitter Impedance And That Is Number EVISION 1 FC. E21' Mechanical 0 Electrical jPlumbing lel Cas Piping City of Tukwila BUII_IDING (DIVISION Commercial — Industrial Fax (253)-269-0268 REVIEWED FOR COM 3LIANCE WITH NF PA 70 - NEC IgV 1 3 .2018 City of Tulcwila— BUILDING DIVISION Olt RECEIVED CITY OF TUKWILA NUV 0 1 2018 iR-ncievq- PERMIT CENTER Revisions: Rev Date Description 8122/18 SHOP 2 10/16/18 10/26/18 SHOP SHOP 4 10/30/18 SHOP Drawn By: RS Sheet Number: El STORAGE 152 EXIST MECH 151 PNL: LP1 CKT: 30 A FACP LP1 EXIST ELEC 150_1 MDP TS2 KP2 KP1 PNL: KP2 CKT: 13< L_ _J ( EXISTING MEN'S 122 EXISTING WOMEN'S 1123 VESTIBULE 121 I 1PNL: KP2 CKT: 16 II _ EXISTING CT CABINET EXISTING 800A MDP DISCONNECT CONCRETE PAD > EXISTING 300KVA TRANSFORMER NEW 400A PANEL (480/277V) i i PNL: KP2 CKT: 15 ms\,, it PNL: KP2 CKT: 17 L. I I OPEN PHYSICAL THERAPY T AREA 145 PROVIDE POWER FOR FUTURE SIGNAGE. COORDINATE LOCATION AND REQURIEMENTS WITH CLIENTNENDOR POWL O 0 A\ 1/4" =1'-0" CORRIDOR 109 PNL: KP2 CKT: 12 IT CLOSET\ 125 PNL: KP2 CKT: 10 11I 111 PNL: KP2 CKT: 14 CI - -Th 11I11 111 PNL: KP1 CKT: 23 < PNL: MDP CKT: 1,3 STOR / HSKP 126 0 CORRIDOR 110 PNL: KP2 CKT: 11 1 PNL: KP2 CKT: 6 PNL: KP2 CKT: 4 PNL: KP2 CKT: 7 GF L' 1rP1� —1+ JI PNL: KP2 > CKT: 9 PNL: KP2 CKT: 8 STAFF LOU 120 , off/ IFIL: KP2 KT: 2 ,A Th 111 111 11 / r PROCEDURE 119 C 11 F= TREATMENT 144 TREATMENT 143 F= > PNL: LP1 CKT: 1 TREATMENT 142 ff PNL: KP1 CKT: 10 A i FI PT SUB-WAITIG 140 II ( )11 II it II( ) II II III' II��iI III _ / \ - / 4•�� 'NL: KP1 CKT: 12 u _ •r PAT TOILET 1,132 VESTIBULE 131 PNL: KP2 CKT: 20 CAST ROOM J PNL: KP1 CKT: 6 124 PNL: KP1 CKT: 24 r -1 PNL: KP2 CKT: 1 L/J GFi GF L r-- /11-6"], L_ L PNL:I<P1 LCKI116 DME & CAST L STORAGE PNL: KP1 CKT:114 < L 1 130 L_ CORRIDOR PNL KP1 CKT: 22 107 PNL: KP1 CKT: 8 A 0 mr •:r�:;Iili 127 0 PARKED TABLE J Al A IMAGING L117 L OWNER EQUIPMENT BY IMAGING CONTROL 1181 PNL: KP1 > CKT: 7 >PNL: KP1 CKT: 9 EOS I0 I1 L ALCOVE PNL: KP1 108-1 CKT. 11 r- 1 1 1 L J MA STATIONS OFFICE MANAGE — 128 fel PNL: KP1 CKT: 15 >PNL: KP1 CKT: 13 WAITING 102 RECEPTION 104 PNL: KP1 CKT: 18 105 PNL: KP1 > CKT: 21 75A 480V 3PH > PNL: H1 CORRIDOR 103 PNL: KP1 CKT: 17 'DOOR CONNECTION �, TV CKT: 1,3,5 CORRIDOR 106 EXAM F 116 PNL: KP1 CKT: 5 EXAM 114 PNL: KP1 CKT: 3 EXAM 113 F= _ EXAM 112 1, PNL: KP1 CKT: 1 A F= T ---t 'IW 1 EXAM 111 F= PNL: KP1 CKT: 2 • ,;I 1 11 • / 11 REVISI Electrical Legend Symbol Description DUPLEX OUTLET DEDICATED DUPLEX OUTLET ... FOURPLEX OUTLET MG ?e? MEDICAL GRADE FOURP X DEDICATED FOUR Lle0MP NFF GFI GFI OUTLET 0 EQUIPMENT CONNE TION NO' MUD RING W/ PULL S RING EWED .FOR MANCE WITH A70 -NEC J 13 2018 OT I UKWII& BUILDING DIVISION RECEIVED CITY OF TUKWILA N1JV 01 2018 PERMIT CENTER Commercial — Industrial N CD co C) a) Q5 c }; o c 1E cn «s M Phone (253)-872-1905 Fax (253)-269-0268 C/11)La) rTl O Eua2ml P=124¢ F-� OP"=° Revisions: Rev Date Description 1 8/22/18 SHOP 2 10/16/18 SHOP 3 10/26/18 SHOP 4 10/30/18 SHOP Drawn By: RS Sheet Number : E2 OE PNL: KP2 CKT: 21 A 4'-0" 0 STORAGE 152 PE PE EX 4 PNL: LPI CKT: 5 0 EB EXISTING MEN'S 122 0 0 DE 0 EXIST MECH (_151 EXIST ELEC 1150 O EX O 0 wmionimmowit EXIS 0 G WOMEN'S 123 0 EB • BE PNL: VESTIBULEcKT PNL: KP2 CKT: 19 ll ORRIDOR\. B PNL: LP1 CKT: 3 AC 10' A0 IM L ING 1117 j 1 E AFF CKT: 2 vr P KT: 2 CE R4DOR 06 CC PROCEDUR 1 ORRID L107 11-111111111 CE PNL: _P1 CKT. 2 IT CLOSET 125 STOR / HSKP 126 AE 41 0 PNL: LP1 CKT: 3 PNL: LP1 CKT: 4 PY T AREA AE C1 Akk AE PNL: LP1 CKT: 2 EX 9' ACP -1 -0"AF GWB AFF Ijilr IEEE 6'-6" 0 TRE TMEN 144 ACP -1 9'-0"AFF oc TREE �TMENT 143 9' i • TR: ►:iTME 142 9' ACP -1 - 0" AFF PNL: CKT _P1< 4 occ OF FICE 41 10 ACP -1 -0"AF F -- I ACP2 10'-0" AFF A CP -1 10' 0" AF CA T ROOM 24 m AE PAT TOILET 132 H PNL: KP1 7"-----CKT: 12 o 0 M DME & OCC STO GE 13 A PNL CK : LP1 : 4 H 1 , 1..wo..���- irivri r MTII. 111111.11 mommon PT SUB -WAITING 1 AC P-1 10 ACP -1 -0"AF MA STAT' 105 AC '-1 10'-0 'AFF Eff- OCC E 11 AC' -1 - I' A - OCC 111111111' AC D-1 'AFF A t OCC 111 °M mirm OCC 'AFF A .1 D11", Ertl ■ A ,3131303-4 1 I WAN CE CE -1 AFF A OCC 1 AFF A L 1 B 11 viiir ill 111111.. 1i OCC PNL LP1 CK 2 1' 0' - J ■ I '1 J O,AFF G i g Aral MEM_AdomoitiAMR' AMINV11'" 11116111111e DE PNL: LP1 CKT:3< 1111, •\Pr' PNL: LP1 CKT: 3 NOTES: EXTERIOR LIGHTING WILL BE CONTROLLED BY ASTRONOMICAL TIME CLOCK RECEIVER CITY OF TUKWILA NUV 01 2013 PERMIT CENTER e 0 37 R VISION Electrical Lighting Legend Type Symbol Description A 0 2x4 LED TROFFER 32W B 2x2 LED TROFFER 32W c 4"X4 RECESSED LED STRIP LIGHT 7W F EXTERIOR LED DOWN LIGHT 13W H 0 RECESSED LED CAN LIGHT 13W RECESSED WALL WASHER 13W J SURFACE MOUNT 18" FIXTURE 12W K 9" LED PENDANT FIXTURE 6W L RESTROOM WALL SCONCES 12W M LED VANITY LIGHT 14W N LED SHOP LIGHT 29W AE 2x4 LED TROFFER 32W w/ EGRESS BALLEST BE 2x2 LED TROFFER 32W w/ EGRESS BALLEST CE 4"X4 RECESSED LED STRIP LIGHT 7W w/ EGRESS BALLEST DE EXISTING EXTERIOR LIGHT w/ EGRESS BALLEST 8W FE EXTERIOR RECESSED LED CAN LIGHT 13W w/ EGRESS BALLEST HE RECESSED LED CAN LIGHT 13W w/ EGRESS BALLEST PE EXISTING STORAGE ROOM LIGHT w/ EGRESS OE Commercial — Industrial Phone (253)-872-1905 O rz4 a Revisions: Rev Date Description 1 8/22/18 SHOP 2 10/16/18 SHOP 10/26/18 SHOP 4 10/30/18 SHOP BALLAST REVIEWED FOR LLEMINCE WIN N LED BAEXITS— SIGN 4WEPA 70_b NEC EXISTING EXTERIOR L EX N/A SWITCH MOUNTED OCCUPANCN ISdR3 2018 N/A 3 3- WAY :1MTCH • N/A CEILING MOUNTED 0 Drawn By: RS ` f -Tukwila 1't rtt DIVISIO Sheet Number : E3 . A PNL: CKT: LP1 4 I • 7 -P-1 --,- II AC 10'-0"AFF A I l II -gam 11 CC STAFF L UNGE 120 AC 10' A0 IM L ING 1117 j 1 E AFF CKT: 2 vr P KT: 2 CE R4DOR 06 CC PROCEDUR 1 ORRID L107 11-111111111 CE PNL: _P1 CKT. 2 IT CLOSET 125 STOR / HSKP 126 AE 41 0 PNL: LP1 CKT: 3 PNL: LP1 CKT: 4 PY T AREA AE C1 Akk AE PNL: LP1 CKT: 2 EX 9' ACP -1 -0"AF GWB AFF Ijilr IEEE 6'-6" 0 TRE TMEN 144 ACP -1 9'-0"AFF oc TREE �TMENT 143 9' i • TR: ►:iTME 142 9' ACP -1 - 0" AFF PNL: CKT _P1< 4 occ OF FICE 41 10 ACP -1 -0"AF F -- I ACP2 10'-0" AFF A CP -1 10' 0" AF CA T ROOM 24 m AE PAT TOILET 132 H PNL: KP1 7"-----CKT: 12 o 0 M DME & OCC STO GE 13 A PNL CK : LP1 : 4 H 1 , 1..wo..���- irivri r MTII. 111111.11 mommon PT SUB -WAITING 1 AC P-1 10 ACP -1 -0"AF MA STAT' 105 AC '-1 10'-0 'AFF Eff- OCC E 11 AC' -1 - I' A - OCC 111111111' AC D-1 'AFF A t OCC 111 °M mirm OCC 'AFF A .1 D11", Ertl ■ A ,3131303-4 1 I WAN CE CE -1 AFF A OCC 1 AFF A L 1 B 11 viiir ill 111111.. 1i OCC PNL LP1 CK 2 1' 0' - J ■ I '1 J O,AFF G i g Aral MEM_AdomoitiAMR' AMINV11'" 11116111111e DE PNL: LP1 CKT:3< 1111, •\Pr' PNL: LP1 CKT: 3 NOTES: EXTERIOR LIGHTING WILL BE CONTROLLED BY ASTRONOMICAL TIME CLOCK RECEIVER CITY OF TUKWILA NUV 01 2013 PERMIT CENTER e 0 37 R VISION Electrical Lighting Legend Type Symbol Description A 0 2x4 LED TROFFER 32W B 2x2 LED TROFFER 32W c 4"X4 RECESSED LED STRIP LIGHT 7W F EXTERIOR LED DOWN LIGHT 13W H 0 RECESSED LED CAN LIGHT 13W RECESSED WALL WASHER 13W J SURFACE MOUNT 18" FIXTURE 12W K 9" LED PENDANT FIXTURE 6W L RESTROOM WALL SCONCES 12W M LED VANITY LIGHT 14W N LED SHOP LIGHT 29W AE 2x4 LED TROFFER 32W w/ EGRESS BALLEST BE 2x2 LED TROFFER 32W w/ EGRESS BALLEST CE 4"X4 RECESSED LED STRIP LIGHT 7W w/ EGRESS BALLEST DE EXISTING EXTERIOR LIGHT w/ EGRESS BALLEST 8W FE EXTERIOR RECESSED LED CAN LIGHT 13W w/ EGRESS BALLEST HE RECESSED LED CAN LIGHT 13W w/ EGRESS BALLEST PE EXISTING STORAGE ROOM LIGHT w/ EGRESS OE Commercial — Industrial Phone (253)-872-1905 O rz4 a Revisions: Rev Date Description 1 8/22/18 SHOP 2 10/16/18 SHOP 10/26/18 SHOP 4 10/30/18 SHOP BALLAST REVIEWED FOR LLEMINCE WIN N LED BAEXITS— SIGN 4WEPA 70_b NEC EXISTING EXTERIOR L EX N/A SWITCH MOUNTED OCCUPANCN ISdR3 2018 N/A 3 3- WAY :1MTCH • N/A CEILING MOUNTED 0 Drawn By: RS ` f -Tukwila 1't rtt DIVISIO Sheet Number : E3 PANEL SCHEDULE PANEL NAME HI 9ani1 i°°`'a'ar"" OLSEN ELECTRIC INC. Phone • 253.872,1905 OIsenelectriCnet Panel Amperage: 4034 Panel Desalption:3 phase. 400 Amp, Main Lug Panel 0 050 010 0 4 0 3 06210,125 Amp, Main Breaker A11 A • C C panty Voltage: 480/277v Panel Type: 3 Phase M In tug Panel Lon.: outside OI EI[[Lrial Room Type Description Load (KVA) Trip Rating CKT 8 }j J • CRT 41 Trip Rating Load (KVA) Desaiptlon Typo EQUIP EQUIP EQUIP In %RAYImMing Ml[h e 2075 20/1 1. --jjj 0.36 - -2 20/1 FEL Spam MMC 4 10 1 / 0.72 Spare MSC 20.75 50/33 1.44 Bottle Cooler 4 2073 REG Sparc MMC 10.75 5- 7- 5- • _-. -8 20/1 0.36 Spare MISC 04450 Spare Cont.,. Mown O0RSated Rerep8rin 20/4 7• ..• - _---..... -' -10 20/1 --10 Spare MMC MIS0 Spam EEC 10/1 3 .- •--..- 20/1 20/1 20/1 Spare MIX MMC Sparc Roan 14S 01310 20/1 11- REC -12 -14 2011 20/1 Space MMC MMC 504m 2401 20/2 13- - •-- `- REC AEC Remo, nGanputm 0.72 20/1 15- 16 20/1 -16 15- • -16 18 001m1450e 043040400441754de 460 REC Recepi00 Re6Cptedea law 8 17 20/1 17- See _. -20 Al KOOK as 48 FEC Recepion Coder 1,44 20/1 19• _. _..__ _-___ -- -20 20/1 1.44 Copier 20/1 REC FEC Recep'lon Computers LOB 21- 21 2011 -24 22 20/1 1.00 ON 128 Receptacles 20/I REC REG MA St Pion Computers xT- 20/1 23 -24 -24 20/1 144 000e127[0mpolecs 23- REC REG Warmrr 25- 20/1 25- -26 -26 20/4 1.a4 Motto Spam REC MGC -28 27- 20/1 27 -28 -14 20/1 111400 27. MGC SPam 29• 29- 29- -30 - -3I -30 Spee MMC 29- Spare .-32 31- -- 31- -34 - -32 Spare MRC MGC 31. -- .34 20/1 33- 33- - 33- 335- 36 Spare NM 33 004m -36 35- 35- 20/1 Spam 400/1 55.25 Transfonner71 EQUIP EQUIP EQUIP 20/1 33 37- 35- 38 50.64 37 MRC 50400 39• 20/0 20/1 -40 -42 50,26 37- 39- 41 -40 -42 41- Spare Load Types Conrl, 11021 1206 Calculated Factor NEC Cale. Load (KVA) N0718- PHASE CONN. LOAD NEC NEC LOAD NEC LOAD (AMM) lhtlType Corel. (KVA) (3741 FACTOR (KVA) ..rw A: 76.60 KVA 4000732 75.00 KVA 274,374 LTS 0.00 1250032 0.00 81 71.39 KVA 200.004 7139 KVA 257.73A 0404 0.00 100.00% 0.00 C: 7101 KVA l00,00% 71.01 KVA 416.35A BEC, 0.00 5000% 0.00 TOTALS: 200.4047A 1000006 208.40106 263.13A NVAC 060 100.00% 0.00 0BC011 BREAKER CODE Kit 000 100.00% OM 1.686 8•too 7.8783 5•SHUNT 481P D• SW)41'NIN60U'TT S.LTS 0.00 100.110% 0.00 EQUIP 218.40 100,0056 21840 MI50 000 100.004 000 FORM: WAG PANEL NAME: DOWNSTREAM LOAD INFORMATION TOTAL 21840 100.00% 218.40 FEEDER LUMP: 100.00% 0.00 REV 1,126 3•RIO MTD 462.01H00 IUDS: FEEDER: 1010.00% EQUIP DATE %/A(% DOUBLE LUGS: PANEt5QiEoo[E 064 E M. ...... OLSEN ELECTRIC INC. Perm Marl.0.0.n:d[m N.we.•.. ...r Panel 0 050 010 0 4 0 3 06210,125 Amp, Main Breaker OR 8 1 A • e • C .....4.440e.v Panel Voltage: 120/204, .....r•:.,..4..., TYle 0.04 a wed NRat rptm 14.11m Type 866 Parol Eoanbrc Ikctxiral Room • I • a t 2034 Pm e•e '3_•.• 0,72 20(1 3 • 20/1 d 20/3 0.36 WailFg Room Ns 20/1 FEL PEG Eam Fawn 113,111 Receptacles 0.72 20/1 0.72 20/1 3. 4 20/4 1.44 Bottle Cooler AEC REG REG Hot Ram 11511600077$2004 0.72 20/1 5- 7- - -6 -6 -- -8 2011 0.36 Procedure 2400, Quad REC REC Cont.,. Mown O0RSated Rerep8rin 144 20/1 9-� t OOP washer --10 srs nu. Room 145 Quad Receptacle 20/1 EEC PEG Cuntnl Roam Oa0oted Receptacle 24. 20/1 11 20/1 -12 20/1 1.44 Roan 14S 01310 11 RFC REC Mete -Table Top 1,44 20/1 13--- ff AEC -,-14 2401 1.44 Oeatmmn132 .14 REC AEC Remo, nGanputm 0.72 20/1 15- 16 20/1 -16 20/1 144 • 001m1450e 043040400441754de 460 REC Recepi00 Re6Cptedea law 8 17 20/1 1.44 See 20/1 Al KOOK as 48 FEC Recepion Coder 1,44 20/1 19- -- '' --- -- -20 20/1 1.44 Copier 20/1 REC FEC Recep'lon Computers LOB 20/1 21 2011 21- 1-23-27- 22 20/1 1.00 ON 128 Receptacles 20/I REC REG MA St Pion Computers 1.08 20/1 23 20/1 -24 20/1 144 000e127[0mpolecs 23- REC REG Warmrr 1.42 20/1 25- - -26 20/4 1.a4 Motto Spam REC MGC -28 20/1 27 -14 20/1 111400 27. MGC SPam 20/1 29- 29- -30 Spee MMC 29- Spare .-32 33-MEMEN 31- - - -32 Spare MRC MGC 31. -- .34 20/1 33- Fik 34 33- 335- Spare NM 33 004m -36 35- 36 20/1 Spam MRC AMC 35- 20/1 33 20/1 35- I -36 38 37 MRC 50400 20/0 20/1 39- 37- 39- 41 -40 -42 MIS[ Spare 42 20/1 Spam 01 39. 41 Com. FNA) -40 -.42 NE66.N- 168800167 41 lhtlType Corel. (KVA) NEC Cakdated Fetor NEC COL. toed {KVA) NOTES: ..rw CONN. 40 rs Conn. (KVA)120160 •320a.m. wa 10100 ras pa woe a[.er•la.eR NEC 1028 NEC LOAD (AMPS) 1.40 recoil teal 1KVM 84.8 (KYAI 125-00% 0.00 8: A: 1004 KVA 17.2532 8.78 NA 5643A 175 CIAO 075.001 10.00 7.91 KVA R: 8t0 KVA 6125% SAS NA IS444 ire.. 100.00% 9.49 80.61% C 10.80 KVA men 54ne• 60.53A 084 15t:]= 50,00% 000 100.40% 701415: 20.9837A art cm nom WAG 0,M 100.00% 000 144 •0MUROREAKE3 CODE %R 000 100.00% 0.00 125002 1,126 3•RIO MTD SLT5 0.00 1010.00% EQUIP 0.00 100.40% ma cue lama son ting.tine 100.00% 0.00 11218080. neat PANEL NAME: [at 5'N .....15 PANEL SCHEDULE PANEL NAME 617-1 P.*540*8wmn OLSEN ELECTRIC INC. PhonC- 253.872.1905 Olsenelectrtc.nel Panelbmperag.: 420A OLSEN ELECTRIC INC. Panel 0 050 010 0 4 0 3 06210,125 Amp, Main Breaker OR 8 1 A • e • C CKT R 3 Panel Voltage: 120/204, Phone - 253.872.1905 OlsenelM Nnet Panel Type: Trip Ratio(KVA)Oesml g 202 3 Pham. M toed 1.44 in Bleaker Door[mnenbn pt fon Type 866 Parol Eoanbrc Ikctxiral Room TITa DescNptiM toad A (KVA) Trip Rating alio REG Eam Ra1m 1111/2 Receptacles 0,72 20(1 3 • 20/1 d 20/3 0.36 WailFg Room Ns 20/1 FEL PEG Eam Fawn 113,111 Receptacles 0.72 20/1 0.72 20/1 3. 4 20/4 1.44 Bottle Cooler AEC REG REG Hot Ram 11511600077$2004 0.72 20/1 5- 7- - -6 -6 -- -8 2011 0.36 Procedure 2400, Quad REC REC Cont.,. Mown O0RSated Rerep8rin 144 20/1 9-� t OOP washer --10 20/1 1.44 Room 145 Quad Receptacle 20/1 EEC PEG Cuntnl Roam Oa0oted Receptacle 1,44 20/1 11 20/1 -12 20/1 1.44 Roan 14S 01310 11 RFC REC Mete -Table Top 1,44 20/1 13--- ff AEC -,-14 2401 1.44 Oeatmmn132 .14 REC AEC Remo, nGanputm 0.72 20/1 15- 16 20/1 -16 20/1 144 Shedder 001m1450e 043040400441754de 460 REC Recepi00 Re6Cptedea 0.54 2071 17 20/1 1.44 IR 20/1 1.44 KOOK 1,44 REC FEC Recepion Coder 1,44 20/1 19- -- '' --- -- -20 20/1 1.44 Copier 20/1 REC FEC Recep'lon Computers LOB 20/1 21 2011 21- 1-23-27- 22 20/1 1.00 ON 128 Receptacles 20/I REC REG MA St Pion Computers 1.08 20/1 23 20/1 -24 20/1 144 000e127[0mpolecs 23- REC REG Warmrr 1.42 20/1 25- - -26 20/4 1.a4 Motto Spam REC MGC -28 20/1 27 -14 20/1 111400 27. MGC SPam 20/1 29- 29- -30 Spee MMC 29- Spare .-32 33-MEMEN 31- - - -32 Spare MRC MGC 31. -- .34 20/1 33- Fik 34 33- 335- Spare NM 33 004m -36 35- 36 20/1 Spam MRC AMC 35- 20/1 33 20/1 35- I -36 38 37 MRC 50400 20/0 20/1 39- 37- 39- 41 -40 -42 MIS[ Spare 42 20/1 Spam MISC 39. 41 Com. FNA) -40 -.42 NE66.N- 168800167 41 lhtlType Corel. (KVA) NEC Cakdated Fetor NEC COL. toed {KVA) NOTES: "MSE CONN. 40 Load Type Conn. (KVA)120160 60602 adaltl NEC oak 10100 PHASE fONN 1028 NEC NEC 1028 NEC LOAD (AMPS) toadIKVA) 8861% 7,69 KVA 1KVM 84.8 (KYAI 125-00% 0.00 8: A: 1004 KVA 17.2532 8.78 NA 5643A 175 CIAO 075.001 10.00 7.91 KVA R: 8t0 KVA 6125% SAS NA IS444 REC 10.00 100.00% 9.49 80.61% C 10.80 KVA 6L25% 7761V4 60.53A 181C0.41010. 18,98 50,00% 000 100.40% 701415: 20.9837A 67.2532 19.491VA 54144 WAG 0,M 100.00% 000 144 •0MUROREAKE3 CODE %R 000 100.00% 0.00 125002 1,126 3•RIO MTD SLT5 0.00 1010.00% EQUIP 0.00 100.40% 0.00 003,0: 54 SNUNTTRM 0a5WR01N6 DUTY MMC 0.00 100.00% 0.00 11218080. DATE PANEL NAME: DOWNSTREAMIOAD1N4ORMAT53N ECRU 7898 67.25% HIDER LENGTH- RPV f[EDTHRU 0165: 19,9 FEEDER: DATE 0/OE 04084E LUGS: PANED SCHEDULE PANEL NAME KP.2. 4_,d0P104141aw OLSEN ELECTRIC INC. PhonC- 253.872.1905 Olsenelectrtc.nel Pa111110.Pe<48.:125A 140/0083.13544* 3 plum, 115 Amp, Malo Breaker A B C Panel04)140 :120208v PaNITyQ: Phau,M in Breaker Pane11Pa0bm Deco.] Roan Type Description 10401 (KVA) TAP Rating 640 B i • i OCT IF T Up Rating Egad (KVA) Description Type REC Cast Room Receptacles 0.54 20/1 1- • 2 20/1 1.44 Salt lounges Receptacles AEC REC Cad Roan (implodes 0.72 20/1 3. 4 20/1 0,36 Staff lounges G4Cs AEC 112 • OEC Cast Room ReCepttdts 0.72 20/1 5- -6 702 4.44 Rd gemter AEC • t 1 -... 4 20/1 0.36 Break Room Microwave RFC REG OOP washer 144 20/1 7-__i-.---_ - -10 20/1 144 R Closet one.. OW Receptacle 100Meal/mornEC NEG Brea kro40010412 Not 1.44 20/1 9- -I -10 Meal/morn Hip040 1.44 20/1 11 12 20/1 1.44 pa.e0eNeedQuWgtoptxk REG ff AEC Rove 1450cdiated QuWFeceplae 1.44 20/1 13. .14 2071 2.44 Room 1450044167C0Roceptads NEC • 16 20/1 1.44 00050145 Microwave REC REG 001m1450e 043040400441754de 1.44 20/1 15- • 18 20/1 1.44 Room 14S ICEMa[hlne REG NEC Roan 1450a1R41ed Quad Recep0We 1,44 20/1 17- 18 20/1 40 20/1 1.44 Ster110er EQUIP 2T5 Worneni Restroom /,44 20/1 19- -- - 2.95 Mens Ne50oan 1.44 2011 21- 1-23-27- 2011 21- - - • -22 20/I Opo! MRC MRC Spam 20/1 23- -24 20/1 23- Spam MRC MMC Spare 2011 25- - -26 20/1 Spam 0406 MGC -28 20/1 27- 28 20/1 111400 27. MGC SPam 20/1 29- immik-30 20/1 Spee MMC 29- Spare .-32 33-MEMEN -32 20/4 Spare MRC MGC 31. -- .34 20/1 33- Fik 34 20/1 Spare NM 33 004m -36 35- 36 20/1 Spam MRC AMC 35- 20/1 33 20/1 Spate MMC 37 MRC 50400 20/0 20/1 39- 40 39- 41 -40 -42 MIS[ Spare 42 20/1 Spam MISC ad Com. FNA) NECCdeolated - Fedor NE66.N- 168800167 41 lhtlType Corel. (KVA) NEC Cakdated Fetor NEC COL. toed {KVA) NOTES: "MSE CONN. 40 NEC NEC LOAD NEC LOAD NEC [ORD{AMM) 115 (KVA) FACTOR (KVA) (AMPS) A[ 932 KVA 8861% 7,69 KVA 64.09A ITS 228 125-00% 3.60 8: 8,g g94 80.61% 6.67 KVA 55,62A REC 10.00 100,00% 10,00 Q 7.91 KVA 80.60% 6.38 KVA 53.214 PEE over 10kva 1142 50.,0% 5.11 TOTALS: 2514 KVA 80.61% 2075 KVA 57.644 INAC 000 100AOSL 000 'CIRCUIT BRUKU CODE KR 000 100.40% 043 04186 MOM RAND 54511UNT TRIP 045WITCNIN6 DUTY 5IT5 0,00 100.00% 0.00 EQUIP 1.44 00000% 144 MIK 000 100.0014 0, 0 FEIHROAt 125002 PANEL RNA{: DOWNSTREAM LOAD 7NOORMA110N TOTAL 25.74 80.61% 20,70 FEEDER LENGTH 003,0: REV X10 THRU611: FEEDER: MARE LUGS: DATE %/K/% 00080E LUGS: AIC @ 16,232A (10-25-18) AIC @ 16,050A (10-25-18) 2 - 2" RIGID W/ 4 - #3/OCU EXISTING 400A 120/208V CT -CAN EXTERIOR (65K AIC RA 1'ED) NEW 400A 480/277V 3PH PANEL HI (75A) AIC @ 15,872A (10-25-18) 2-2" RIGID W/ 4 - #3/OCU AIC @ 8,434A (10-25-18) 3-3"PVC W/ 4 #300CU EXISTING TRANSFORMER TI 480/277V TO 120/208V 3PH EXISTING MDP DISCONNECT 120/208V 3P (FUSED @ 800A) AIC @ 8,020A (10-25-18) 3-3" PVC W/ 4 - #300CU BUILDING 75A 480V 3PH / IMAGING MACHINE CONNECTION EXISTING MDP 800A 120/208V 3PH 1-1 -"EMT W/4-#1CU AIC @ 7,245A (10-25-18) EXISTING MLO 125A 120/208V KP1 1-11"EMT W/4-#1CU AIC @ 7,245A (10-25-18) EXISTING MLO 1 25A 120/208V KP2 1 - 1 " EMT W/4-#110CU AIC @ 7,425A (10-25-18) - EXISTING MLO 150A 120/208V LPI 3 - 3 1/2" PVC W/ 4 - #600AL TO EXISTING / 300KVA UTILITY TRANSFORMER (AIC @ 17,200A) PANEL SCHEDULE PANEL NAME LP -1 Pam spen0otias OLSEN ELECTRIC INC. Phone• 253.872.190501seneleotrk.net 010.0*mperage:15tw Panel Des[alp0on: 3 phase, 150 Amp, Main Breaker A B C Panel Voltage:120208v Pard 40.0100: Electrical Room Panel .3 Phaw,M ka 0,016er Type Description Load (KVA) Trip Rating GRr 4I CKT K Trip Rating Load (KVA) Description TYP. 119 SIg11 144 20/1 1- -2 20/1 1113 Ewen Room/Corridor 11gh1ng (39 175 Eateriortights 036 20/1 3- • 4 20/1 112 Corridor/ Treatment/P,T,Ughoeg 195 LT5 SetraKe/Mevl0anio4Roem Lighting 144 20/1 5. • 4 20/1 Spam MGC MMC Spare 20/1 7• -i........- .- -8 20/1 Sparc MGG NOW Spare 20/1 9- • -10 20/1 Spm MISC MLS[ Spam 20/1 11- ff 12 20/1 Spare MGC MSC Spore 20/1 33 • -14 20/1 Moe MMC MGC Spam 20/1 15- -16 20/1 Spate MISE MRC Spam 20/5 17 18 20/1 Spare MDG MMC Spare 20/1 19- -20 20/1 Spam MGC MIS0 Space 2011 21- - - • -22 20/I Opo! MRC MRC Spam 20/1 23- -24 20/1 Spam MRC MMC Spare 2011 25- - -26 20/1 Spam 0406 MGC 5711. 20/1 27- 28 20/1 111400 MMC MGC SPam 20/1 29- immik-30 20/1 Spee MMC MMC Spare 40/4 33-MEMEN -32 20/4 Spare MRC MGC Spare - 20/1 33- Fik 34 20/1 Spare NM MMC 004m 20/1 35- 36 20/1 Spam MRC AMC Spare 20/1 37- 20/1 Spate MMC -38 MRC 50400 20/0 20/1 Spare MU 39- 41 -40 -42 MIS[ Spare 20/1 20/1 Spam MISC ad Com. FNA) NECCdeolated - Fedor NE66.N- 168800167 NOTES: CONN.LCAD NEC NEC LOAD [KVA) PEVA) FACTOR (CVA) NEC [ORD{AMM) 115 S.39 1250036 6.74 A: 747 KVA 225.001 3.09 KVA 25.734 REG 0.00 709.08% 0.00 & 1.48 EVA 1250834 1.85 KVA 15.424 006000500?. 0,00 5011032 0.00 C 3.44 EVA 1250032 180104 MOO LMAC 0.00 100110% OEG TOTALS: 530KVA 135.00% 6.748VA 1872A KR 035 700.001 043 mom 0464018woe 1,115 0.40 100.0032 0.80 04166 64408141110 54531UNT TRIP 0. SWITCHING Dull EQUIP OM 100.003 000 MDC 0-0D 50000% 0.00 HOME%.k PANEL NAME OOWNSTRUMIDADINFORAEATIM TOTAL 5.39 125002 6.]4 FEEDER MGM:REV FEEOMU LUGS: 003,0: DATE K/lt/3 MARE LUGS: R ELI 3-O't 3`7 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC NOV 13 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NUV 01 ma PERMIT CENTER 253)-269-0268 c/D W PLI µy 3� E-4 m3 g1:4 P-4 Revisions: Rev Date Description 1 8122/18 SHOP 2 10/16/18 SHOP 10/26/18 SHOP 4 10/30/18 SHOP Drawn By: RS Sheet Number : E4