Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL18-0951 - SHOWALTER MIDDLE SCHOOL - ELECTRICAL, TELECOMMUNICATIONS AND ALARMS FOR NEW BUILDING AND ADDITIONS
SHOWALTER MIDDLE SCHOOL 4628 S 144T" ST ELI 8-0951 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 1523049164 4628 S 144TH ST ELECTRICAL PERMIT Project Name: SHOWALTER MIDDLE SCHOOL Permit Number: EL18-0951 Issue Date: 4/15/2019 Permit Expires On: 10/12/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST , TUKWILA, WA, 98168 SUSAN NEATON ROLLUDA, 105 S MAIN ST #323 , SEATTLE, WA, 98104 PACIFIC COAST ELECT CONTR INC 16620 NORTH ROAD , BOTHELL, WA, 98021-5908 PACIFICE077MA Phone: (206) 624-4222 Phone: (425) 741-2700 Expiration Date: 7/8/2019 DESCRIPTION OF WORK: ELECTRICAL, TELECOMMUNICATIONS. LOW VOLAGE, ALARMS FOR NEW CLASSROOM BUILDING AND ADDITIONS TO EXISITING Valuation of single family: $0.00 Valuation of mf/comm: $1,168,224.00 Type of Work: LOW VOLTAGE Fees Collected: $14,938.12 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signa 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: q -i C% I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: z7 Print Name: -5C0 >q Pd.) ccv /1 Date: K —1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKIC)I Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use on v) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 140)215f Site Address: 4624S 144th Street Tenant Name: Showalter Middle School King Co Assessor's Tax No.: 152304-9108 Suite Number: Floor: New Tenant: 0 Yes ..No PROPERTY OWNER Name: Susan Neaton Address: Rolluda, 105 S Main St # 323 Name: Tukwila School District Phone: (206) 624-4222 Fax: Email: susan@rolludaarchitects.com Address: 4640 S 144th Street City: State: City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Susan Neaton Address: Rolluda, 105 S Main St # 323 City: Seattle State: WA Zip: 98104 Phone: (206) 624-4222 Fax: Email: susan@rolludaarchitects.com Valuation of Project (contractor's bid price): 1,168,224 ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; 105 S Main Scope of Work (please provide detailed information): Electrical, telecommuniations, low volage, alarms for new classroom building and additions to existing Will service be altered? 0 Yes No Adding more than 50 amps? CD Yes 66 No Type of Use: Education Type of work: W New W Addition 12 Service Change WI Remodel WI Tenant Improvement g Low Voltage W Generator W Fire Alarm W Telecommunication W Temporary Service Property Served by: 2 Puget Sound Energy 21 Seattle City Light W•IPerrnii CenterIAppications-HandoutsTermil Applications,PDFOElectrical Permit Application Revised I-I-17.doca Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $155.91 (including an attached garage) O Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) O Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 O Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — En all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER tfEJECTRICAL CONTRACTOR: Signature: [/ �% �/ `_. Date: • Print Name: Alexander Clark Day Telephone: (206) 624-4222 Mailing Address: Rolluda Architects, 105 S Main St #323 Seattle WA 98104 City W:\Permit Center\Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised 1-1-17.docx Revised; January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $10.30 EL18-0951 Address: 4628 S 144TH ST Apn: 1523049164 $10.30 Credit Card Fee $0.30 Credit Card Fee R000.369.908.00.00 0.00 $0.30 TECHNOLOGY FEE $10.00 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17403 R000.322.900.04.00 0.00 $10.00 $10.30 Date Paid: Monday, April 15, 2019 Paid By: PACIFIC COAST ELECT CONTR INC Pay Method: CREDIT CARD 315163 Printed: Monday, April 15, 2019 11:36 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $12,055.16 EL18-0951 Address: 4628 S 144TH ST Apn: 1523049164 $12,055.16 ELECTRICAL $11,490.63 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $11,490.63 TECHNOLOGY FEE $564.53 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17402 R000.322.900.04.00 0.00 $564.53 $12,055.16 Date Paid: Monday, April 15, 2019 Paid By: PACIFIC COAST ELECT CONTR INC Pay Method: CHECK 053739 Printed: Monday, April 15, 2019 11:34 AM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 04/15/2019 11:36:11 AM CREDIT CARD SALE VISA CARD NUMBER: **********6896 K TRAN AMOUNT: $10.30 APPROVAL CD: 315163 RECORD #: 000 CLERK ID: kandace Thank you! Customer Copy Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY PAID $35,756.10 D18-0348 Address: 4628 S 144TH ST Apn: 1523049164 $28,061.38 DEVELOPMENT $28,061.38 PERMIT FEE R000.322.100.00.00 0.00 $398.73 PLAN CHECK FEE R000.345.830.00.00 0.00 $20,490.85 STRUCTURAL CONSULTANT R000.345.830.01.00 0.00 $7,171.80 E118-0951 Address: 4628 S 144TH ST Apn: 1523049164 $2,872.66 ELECTRICAL $2,872.66 PLAN CHECK FEE R000.345.832.00.00 0.00 $2,872.66 M18-0144 Address: 4628 S 144TH ST Apn: 1523049164 $4,822.06 MECHANICAL $4,822.06 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15758 R000.322.102.00.00 0.00 $4,822.06 $35,756.10 Date Paid: Friday, November 02, 2018 Paid By: TUKWILA SCHOOL DISTRICT Pay Method: CHECK 98149 Printed: Friday, November 02, 2018 2:21 PM 1 of 1 SYSTEMS Zl INSPECTION NO. INSPECTION RECORD Retain a copy with permit i�c�-o�sl PERMIT NO. CITY OF TUKWILA BUILDING DIVISION L 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: $l�A J,(1,rLq Tr • f spectior�C D Address: /1(9 ZA3 -.5 - /Of Sr I ate Ca led: Special Instructions: Date Wanted: 7/0 2- a.m. P.m. Requester: Phone No: i4itoa 7 11 57 Approved per applicable codes. Corrections required prior to approval. OMMENTS: okki4dertol.f? tikt? lk Date: ?/02.12.0 REINSPECTI N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 4/1/2019 City of Tukwila Department of Community Development SUSAN NEATON ROLLUDA, 105 S MAIN ST #323 SEATTLE, WA 98104 RE: Permit Application No. ELI 8-0951 SHOWALTER MIDDLE SCHOOL 4628 S 144 STREET Dear SUSAN NEATON, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 11/2/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 5/2/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, -(1 Kandace Kandace Nichols Permit Technician File No: ELI8-0951 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Hume ligpani)l Cnntnl Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I A -Z Index lielp My 11 Workplace Rights Trades & Licensing PACIFIC COAST ELECT CONTR INC Owner or tradesperson Principals BLACKBURN, R DAVID, PRESIDENT ROTHERMEL, RICK A, VICE PRESIDENT BLACKBURN, R DAVID, AGENT Doing business as PACIFIC COAST ELECT CONTR INC WA UBI No. 601 473 603 16620 NORTH ROAD BOTHELL, WA 98012-5908 425-741-2700 SNOHOMISH County Business type Corporation Governing persons R DAVID BLACKBURN RICK ROTHERMEL; DALE M CAMPBELL; (DO1 -- vz License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. PACIFCE077MA Effective — expiration 07/01/1993— 07/08/2019 Designated administrator .......... .............................. BLACKBURN, RALPH DAVID License type Electrical Administrator Bond Federated Mutual Ins Co Bond account no. 6055752 Active. Meets current requirements. License no. BLACKRD066CE $4,000.00 Received by L&I Effective date 09/27/2017 09/21/2017 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Help us improve Workers' comp 0 0-1 Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 848,659-00 Doing business as PACIFIC COAST ELECTRICAL CONTR Estimated workers reported Quarter 4 of Year 2018 "31 to 50 Workers" L&I account contact T5 / LINDSAY BARLOW (360)902-4735 - Email: BLIN235 r@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/15/2013 Inspection no. 316625920 Location 12401 SE 320th St Auburn, WA 98092 No violations Labor 8 rnduslrtes. Uga of this site is subject to the laws of the state of Washington. Help us improve ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION LIGHTING OR POWER PANELBOARD CONDUIT EXPOSED CONDUIT CONCEALED IN WALL OR CEILING SPACE ONLY CONDUIT UNDER GROUND, UNDER FLOOR/SLAB, OR IN FLOOR/SLAB CONDUIT UP CONDUIT DOWN EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. EQUIPMENT CONNECTION WITH LIQUID TIGHT FLEX TO MATCH EQUIPMENT SPECIAL RECEPTACLE TYPE TO MATCH EQUIP SERVED, VERIFY REQUIREMENTS MOTOR CONNECTION NON -FUSED DISCONNECT SWITCH. RATING AS SHOWN (3-POLE, UNO) FUSED DISCONNECT SWITCH, SWITCH RATING (60AS) AND FUSE SIZE (50AF) AS SHOWN (3-POLE, UNLESS NOTED OTHERWISE) MOTOR -RATED SWITCH ENCLOSED CIRCUIT BREAKER DISCONNECT MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION VARIABLE FREQUENCY DRIVE (VFD) (FURNISHED BY M.C., UNO) ELECTRICAL CONTACTOR, TYPE AS INDICATED PUSH BUTTON SWITCH TO MATCH EQUIPMENT STARTER AND CONTROLLER RED EMERGENCY SHUT-OFF PUSH BUTTON HEAT/FAN COMBO DEVICE INDICATOR: A=ABOVE COUNTER, WP=WEATHERPROOF, TR=TAMPER RESISTANT, IG = ISOLATED GROUND, CL = CLOCK OUTLET, C = CONTROLLED RECEPTACLE DUPLEX RECEPTACLE POKE-THRU DEVICE WITH DEVICES AS NOTED ON PLANS DUPLEX RECEPTACLE, CEILING MOUNTED DUPLEX RECEPTACLE GFCI TYPE TWO DUPLEX RECEPTACLES IN COMMON BACKBOX AND COVERPLATE TWO DUPLEX GFCI RECEPTACLES IN COMMON BACKBOX AND COVERPLATE -- -- -- - SURFACE METAL RACEWAY WITH DEVICES AS INDICATED. PROVIDE COMPLETE DEVICES, FITTINGS AND ASSEMBLIES. OC. SPACING OF DEVICES ARE AS NOTED ON PLANS. MULTI -GANG RECESSED FLOOR BOX .SUBTEXT INDICATES TYPE, SEE PLANS FOR EXACT DEVICE TYPES AND QUANTITIES. WIRELESS ACCESS POINT (WAP) WALL OR CEILING MOUNT SUBNUMBER = QUANTITY OF DROPS (TWO DROPS UNLESS NOTED OTHERWISE) TELECOMMUNICATIONS OUTLET, SUBNUMBER=QUANTITY OF DROPS - TYPICAL LIGHT FIXTURE IDENTIFIERS: LIGHT FIXTURE TYPE, SEE LIGHT FIXTURE SCHEDULE. USX' to \"N SWITCH LEG/ZONE ID POWER CIRCUIT NUMBER SHADING INDICATES EMERGENCY PER UL924 EXTERIOR POLE MOUNTED LIGHT FIXTURE, SEE SCHEDULE FOR TYPE EMERGENCY LIGHT M-O --0 -• 1=lb CONDUIT STUB OUT WITH PLASTIC BUSHING BRANCH CIRCUIT HOME RUN (3/4t, #12 CONDUCTORS AND #12 GND, UNO) GROUNDING ELECTRODE PER CODES FLEXIBLE CONDUIT EXISTING CONDUIT ® $ $3 $M $P EXIT LIGHT SINGLE POLE SWITCH THREE WAY SWITCH (4 = 4-WAY SWITCH) MOMENTARY CONTACT SWITCH PILOT LIGHTED SWITCH J ^.•1/4 --{II +, i0••av: OO ( VIP EXISTING CONDUIT UNDERGROUND DEMO CONDUIT UNDERGROUND ELECTRICAL SERVICE CONDUIT TELECOM SERVICE CONDUIT CONDUIT DUCTBANK. ORIENTATION AS SHOWN. NUMBERS IDENTIFY CONDUIT DIAMETER SIZES. (PULL -WIRES SHALL BE INSTALLED IN ALL CONDUITS) CABLE TRAY. PROVIDE TYPE PER PLANS & SPECS. LOW -VOLTAGE WIRING CODE SIZED PULLBOX WITH COVER CODE SIZED HANDHOLE WITH NON-SKID COVER (ID# AS SHOWN) CODE SIZED JUNCTION BOX WITH COVER PLATEa„5 GROUNDING ELECTRODE ROD/CONDUCTOR (TW = TEST WELL) GROUND BUS BAR (REFER TO DETAILS AND SPECIFICATIONS) - - -- - -- -- - --- - GROUNDING ELECTRODE CONDUCTOR ELECTRICAL METER EMERGENCY RESPONSE SYSTEM HEADEND EQUIPMENT EMERGENCY RESPONSE SYSTEM 3-WAY SPLITTER - - - - - EMERGENCY RESPONSE SYSTEM ANTENNA FIRE ALARM CONTROL PANEL FIRE ALARM LCD ANNUNCIATOR --- - - - - FIRE ALARM SMOKE DETECTOR FIRE ALARM COMBINATION SMOKE/CARBON MONOXIDE DETECTOR FIRE ALARM SMOKE DETECTOR, DUCT TYPE FIRE ALARM HEAT DETECTOR, RATE -OF -RISE TYPE FIRE ALARM HEAT DETECTOR, FIXED TEMPERATURE TYPE FIRE ALARM CONNECTION, TYPE AS NOTED ON PLANS - - - - -- - - - - TAMPER SWITCH FIRE ALARM MONITORING CONNECTION FLOW SWITCH FIRE ALARM MONITORING CONNECTION FIRE ALARM AUDIO-VISUAL NOTIFICATION DEVICE FIRE ALARM STROBE LIGHT CEILING MOUNTED FIRE ALARM AUDIO-VISUAL SPEAKER/STROBE LIGHT FIRE ALARM MANUAL PULL STATION, D=DUAL ACTION TYPE. FIRE ALARM DOOR HOLD -OPEN FIRE ALARM KNOX BOX - - - -- -- - COMBINATION FIRE/SMOKE DAMPER FIRE ALARM AUDIO NOTIFICATION DEVICE BELUBUZZER POST INDICATOR VALVE - -- -- $K $D Sr $00 SYS SA SLY Sl/ $ID Sr ;u E ® 9 ® ® ® ® ® KEY OPERATED SWITCH MANUAL DIMMER SWITCH TIMER SWITCH WALL MOUNT OCCUPANCY SENSOR WITH PUSHBUTTON ON/OFF SWITCH WALL MOUNT VACANCY SENSOR SWITCH - P - - T - ce,, y °0 0 WALL MOUNT VACANCY SENSOR SWITCH WITH DIMMING CONTROL WALL MOUNT LOW VOLTAGE SWITCH WALL MOUNT LOW # INDICATES OVERRIDVOLTAGE LIGHTING CONTROL ZONE OVERRIDE SWITCH. E ZONE NUMBER. WALL MOUNT LOW VOLTAGE SWITCH WITH DIMMING CONTROL TIMER SWITCH LIGHTING CONTROL SYSTEM ROOM CONTROLLER (UL 924 FOR EM LTS) LIGHTING CONTROL SYSTEM POWER PACK LIGHTING CONTROL UL 924 TRANSFER DEVICE FOR SWITCHED/DIMMED EM LTS LIGHTING CONTROL CEILING MOUNTED PHOTOCELL/DAYLIGHT SENSOR STANDARD PRIMARY AND SECONDARY DAYLIGHT ZONES. REFER TO PLANS FOR SPECIFIC DAYLIGHT ZONES WITH SUBSCRIPT X,X ZONE IDENTIFIERS. LIGHTING CONTROL OCCUPANCYNACANCY SENSOR, WALL MOUNT. (DUAL TECHNOLOGY VACANCY SENSOR, UNLESS NOTED OTHERWISE) LIGHTING CONTROL OCCUPANCYNACANCY SENSOR, CEILING MOUNT. (DUAL TECHNOLOGY VACANCY SENSOR, UNLESS NOTED OTHERWISE) - - - - - - - --- AUDIO VISUAL OUTLET FOR VIDEO PROJECTOR, WALL OUTLET AUDIO VISUAL OUTLET FOR VIDEO PROJECTOR, CEILING OUTLET AUDIO VISUAL OUTLET FOR VIDEO PROJECTOR, FLOOR OUTLET TV OUTLET - IIIIIIIIM PB HH-XX-XXX OJ TW M .-1I' Pi -GND- - el O in FB/ ®2 V2 --- DE w ��7f1'C�� ® DM ERS ES 0 PHONE JACK - - - -- - SECURITY SYSTEM MOTION DETECTOR SECURITY SYSTEM MOTION DETECTOR, CEILING MOUNTED, 360° SECURITY SYSTEM KEY PAD SECURITY SYSTEM CAMERA FAP FAA ® ®CO ®'c 0 OH OHF O ® ® F A E F D K AUDIO-VISUAL INPUT JACK. PROVIDE RACEWAY AND BACKBOX, COORDINATE WITH OWNER FOR FACEPLATE AND CABLING. SOUND SYSTEM AMPLIFIER SOUND SYSTEM IR RECEIVER -- SOUND SYSTEM SPEAKER - 2X2 LAY IN WALL MOUNTED SOUND SYSTEM SPEAKER HDMI INPUT TO DISPLAY WITH (1) 1!4" AUDIO OUTPUT FROM [SSA] OUTPUT (1)HDMI TO DISPLAY FROM COMPUTER & (1) LEFT/RIGHT RCA OUTPUT FROM )SSA] TO DISPLAY. - - - - - AUDIO VISUAL CONTROL PANEL. MOUNT AT +48" UNO. SOUND SYSTEM IR DETECTOR SSA --- ® E, ® Z O SECURITY SYSTEM DOOR CONTACT ACCESS CONTROL SYSTEM CARD READER ACCESS CONTROL SYSTEM CARD READER CONTROL DEVICE ACCESS CONTROL SYSTEM ELECTRIC DOOR STRIKE ACCESS CONTROL SYSTEM ELECTRIC DOOR LATCH RETRACTION IRR SS AV1 - ------ ACCESS CONTROL SYSTEM DOOR POWER SUPPLY AND CONTROL DEVICE ADA AUTOMATIC DOOR OPENER MASTER CLOCK SYSTEM EQUIPMENT INTERCOM CONSOLE INTERCOM DIGITAL DISPLAY INTERCOM HANDSET, ADM=ADMIN TYPE WITH DISPLAY D=DESK TYPE INTERCOM WALL OR CEILING SPEAKER INTERCOM WEATHERPROOF OUTDOOR HORN/SPEAKER RESCUE ASSISTANCE CALL STATION - - - - RESCUE ASSISTANCE BASE STATION AV2 AVC MC ® - Q ® - - IC MICROPHONE JACK SOUND SYSTEM AUXILIARY INPUT - - -_-- - - - -- - - --- --------- --- - - - DD . _ 0 0 S ----- CS J • F © ® BS ABBREVIATIONS ABBRV DESCRIPTION ABBRV DESCRIPTION ABBRV DESCRIPTION ABBRV DESCRIPTION ABBRV DESCRIPTION ACP AFC ACCESSIBLE CARD PATH AVAILABLE FAULT CURRENT EF - EQPT EXHAUST FAN ----- - - - - - - --- EQUIPMENT LTG - LV LIGHTING - LOW -VOLTAGE OFOI OWNER -FURNISHED, OWNER -INSTALLED SW TEL SWITCH TELEPHONE AFF ABOVE FINISHED FLOOR (E) EXISTING MC MECHANICAL CONTRACTOR OL OVERLOAD TC TELECOMMUNICATION ATS AUTOMATIC TRANSFER SWITCH (F) FUTURE MDF MAIN DISTRIBUTION FRAME P PHASE, POLE THRU THROUGH AL ALUMINUM F FURNACE , FARENHEIGHT MDP MAIN DISTRIBUTION PANEL PNL PANEL, PANELBOARD (TYP) TYPICAL BKR BREAKER FAAP FIRE ALARM ANNUNCIATOR PANEL MECH MECHANICAL PS PROJECTION SCREEN UNO UNLESS NOTED OTHERWISE C CONDUIT FACP FIRE ALARM CONTROL PANEL MH MANHOLE PV PHOTOVOLTAIC W WIRE CKT CIRCUIT G, GND GROUND MLO MAIN LUGS ONLY RCPT RECEPTACLE WH WATER HEATER CO CONDUIT AND PULL WIRE ONLY G.C. GENERAL CONTRACTOR MR MOTOR RATED SWITCH REF REFERENCE, REFRIGERATOR WP WEATHERPROOF COMM COMMUNICATION GFCI GROUND FAULT CIRCUIT INTERRUPTER (N) NEW REX REQUEST -TO -EXIT XFMR TRANSFORMER CTRL CONTROL GFP GROUND FAULT PROTECTION N NEUTRAL SDP SECONDARY DISTRIBUTION PNL CU COPPER HH HANDHOLE NEC NATIONAL ELECTRICAL CODE SPD SURGE PROTECTION DEVICE EC ELECTRICAL CONTRACTOR IDF INTERMEDIATE FRAME OFCI SPECSSTB ECB ENCLOSED CIRCUIT BREAKER LCP LIGHTING CONTROL CENTERN CONTRACTOR NS ALLED SHUNT'TRIP BREAKER GENERAL REQUIREMENTS 1. PROVIDE COMPLETE WORK FOR REQUIREMENTS AS DESCRIBED ON LEGEND. 2. ALL FLUSH MOUNT EQUIPMENT, CABINETS, AND PANELBOARDS SHALL HAVE FACTORY TYPE FLUSH MOUNT TRIM KIT FOR COMPLETE INSTALLATION. 3. PROVIDE ALL MATERIAL AND LABOR RELATED TO THE INSTALLATION OF ELECTRICAL DEVICES PENETRATING INTO OR THROUGH FIRE RATED WALLS, FLOORS, OR CEILINGS SUCH THAT THE FIRE RATING OF THE WALL IS MAINTAINED. 4. DO NOT TAKE MEASUREMENTS FROM PLANS FOR DEVICE LOCATIONS. FIELD VERIFY EXACT DEVICE, EQUIPMENT LOCATIONS, AND MOUNTING HEIGHTS WITH OWNER'S REPRESENTATIVE FOR PROPER INSTALLATION. 5. BRANCH CIRCUIT HOME RUNS ARE NOT INDICATED WITH NUMBER OF CONDUCTORS! WIRES PROVIDE ALL BRANCH CIRCUIT CONDUCTORS/ WIRES AS REQUIRED FOR COMPLETE OPERATION OF ALL DEVICES AND EQUIPMENT INDICATED. PROVIDE INDIVIDUAL NEUTRALS FOR EACH CIRCUIT. 6. REFER TO EQUIPMENT SCHEDULES FOR WIRING REQUIREMENTS NOT INDICATED ON POWER PLANS. 7. PROVIDE ALL WIRING TO PANELS AND POWER DISTRIBUTION EQUIPMENT IN ACCORDANCE WITH ONE -LINE POWER DIAGRAM. 8. INCLUDE COST OF PROVIDING ALL ELECTRICAL CONNECTIONS AS REQUIRED FOR FULL OPERATION OF ALL OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT. SEE ARCHITECTURAL DRAWINGS TO VERIFY LOCATIONS. 9. COORDINATE PAINTING WORK OF ELECTRICAL ITEMS WITH GENERAL CONTRACTOR. SEE PAINTING SPECIFICATIONS FOR REQUIREMENTS. 10. VERIFY ALL LIGHT FIXTURE TYPES, VOLTAGE, AND MOUNTING METHODS TO SUIT BUILDING STRUCTURE, CEILING SYSTEM, TRUSS, JOISTS, AND SUPPORTING SURFACES. ALL FIXTURE MOUNTING HEIGHTS SHALL BE APPROVED OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. VERIFY CORRECT CATALOG NUMBERS PRIOR TO ORDERING OF FIXTURES. REFER TO CONTRACT DRAWINGS FOR LOCATIONS OF EMERGENCY FIXTURES. 11. ALL EMERGENCY LIGHT FIXTURES SHALL BE RATED FOR 90 MINUTES OF CONTINUOUS OPERATION. 12. PROVIDE UNSWITCHED HOT CONDUCTOR FOR ALL BATTERY BACKED FIXTURES. 13. PROVIDE SEPARATE NEUTRALS FOR ALL BRANCH CIRCUITS. 14. WIRING SYSTEMS SHALL BE CONCEALED WHERE POSSIBLE, EXCEPT IN ELECTRICAL ROOM, MECHANICAL ROOM, AND UTILITY AREAS, OR AS OTHERWISE NOTED. 15. PROVIDE SURFACE METAL RACEWAY AS WIRING METHOD WHERE OUTLETS AND WIRING CANNOT BE CONCEALED. 16. EXTERIOR MOUNTED ELECTRICAL DEVICES (SUCH AS DISCONNECT SWITCH, STARTER, SPEAKER, FIRE ALARM HORN, ETC.) AND COVERS SHALL BE NEMA-3R WEATHERPROOF RATED. 17. PROVIDE CONDUIT AND WIRE FROM ALL HVAC UNITS 2000 CFM OR ABOVE TO FIRE ALARM PANEL FOR HVAC UNIT CONTROL. CONDUIT AND WIRE MAY NOT BE INDICATED IN ELECTRICAL DRAWINGS. 18. PROVIDE TEMPORARY POWER FOR CONSTRUCTION. TEMPORARY POWER MAY BE IN THE FORM OF PORTABLE GENERATOR SET; CONNECTION TO UTILITIES COMPANY'S POWER POLE OR EXISTING FACILITY'S ELECTRICAL SYSTEM. 19. VERIFY WITH CABINET INSTALLER FOR ALL CABINET LOCATIONS, DIMENSIONS, AND COUNTER HEIGHTS PRIOR TO OUTLET ROUGH -IN. OUTLETS LOCATED ABOVE COUNTER SHALL BE INSTALLED TO CENTERLINE ABOVE COUNTERTOP BACKSPLASH, AS DIRECTED OR INDICATED IN SPECIFICATIONS. VERIFY HEIGHT WITH OWNER'S REPRESENTATIVE OF ANY LOCATION THAT CANNOT ACCOMMODATE MOUNTING HEIGHT. ELi 8-095 1 GENERAL REQUIREMENTS 20. DO NOT INSTALL FLUSH WALL OUTLETS BACK TO BACK. A MINIMUM OF 24* SEPARATION IS REQUIRED BETWEEN ANY OUTLET INSTALLED ON FIRE RATED WALL. 21. INSTALLATION OF UNDERGROUND WIRING SYSTEMS SHALL INCLUDE EXCAVATION, CUTTING, PATCHING, BACKFILL, AND COMPACTION. DO NOT CUT OR DAMAGE ANY EXISTING UTILITIES, STRUCTURAL MEMBERS, OR BUILDING FOUNDATIONS. VERIFY EXISTING CONDITIONS PRIOR TO EXCAVATION WORK. INCLUDE COST FOR UNDERGROUND LOCATOR SERVICE TO IDENTIFY LOCATIONS OF EXISTING COMPONENTS. HAND EXCAVATE IN LOCATIONS WHERE EXISTING UNDERGROUND COMPONENTS ARE SUBJECT TO DAMAGE. REPAIR DAMAGE TO EXISTING UTILITIES OR BUILDING STRUCTURE TO OWNER'S SATISFACTION AT THE CONTRACTORS EXPENSE. 22. ALL ONE -LINE DIAGRAMS AND RACEWAY ROUTING ARE SCHEMATIC AND DO NOT SHOW EXACT PHYSICAL ARRANGEMENT OF EQUIPMENT ON DRAWINGS. ALL JUNCTION BOXES, AND PULLBOXES SHOWN ARE MINIMUM REQUIREMENTS. PROVIDE FITTINGS AND PULLBOXES OF ADEQUATE SIZE IN RACEWAY SYSTEMS WHEREVER NECESSARY OR REQUIRED BY NATIONAL ELECTRICAL CODE. PROVIDE EXPANSION JOINT FITTINGS FOR RACEWAY PASSING THROUGH NEW OR EXISTING EXPANSION JOINTS INSTALLED BETWEEN BUILDINGS. VERIFY EXACT LOCATIONS AND DETAILS OF EXPANSION JOINTS PRIOR TO WORK. COORDINATE ALL RACEWAY ROUTING, PULLBOXES, AND EQUIPMENT LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS OF EQUIPMENT INSTALLATIONS. ALL EMPTY CONDUITS SHALL HAVE PULL WIRES. 23. CONDUIT OR OTHER ELECTRICAL COMPONENTS SHALL NOT BE INSTALLED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR APPROVED BY STRUCTURAL ENGINEER. 24. PROVIDE ELECTRICAL CONNECTION FOR ALL FAN SPEED SWITCHES COORDINATE LOCATION OF CONNECTIONS WITH MECHANICAL CONTRACTOR. 25. PROVIDE SEPARATE AS BUILT DRAWINGS FOR VOICE AND LAN DROPS AND PA SYSTEM ON CAD DRAWINGS SHOWING LOCATIONS OF JACKS BY NUMBER, LOCATIONS OF SPEAKERS AND WIRE PATHS TO THE SPEAKERS. 26. ALL SYMBOLS ON LEGEND MAY NOT BE SHOWN. E,.:.,,cal C_s PRp:ng C ctT''.i'3 P E`':s,f` 's No chan s r•-- ,,r.,r,.. Of V1. ,-.- FILE Cr 7Y mm Plan r=v e ' a Approval cf L the violatrtn of approved F;c.i C:.py LIT,3 :_..,•,•,.,J• .._........._ r• Date: cr-f -(ci CI y cP T Ta BUILDuvu C V I,;ICN 3 ELECTRICAL DRAWING INDEX SHEET NO. SHEET TITLE E0.01 E0.02 E1.01 ED1.01 ED1.02 ED1.03 ED1.04 E2.11 E2.21 E2.21A E2.22 E2.22A E2.31 E2.31A E2.51 E3.11 E3.21 E3.22 E4.12 E4.21 E4.22 E4.23 E4.31 E3.11 E5.21 E5.22 E5.31 E6.01 E6.02 E7.01 E7.02 ELECTRICAL LEGEND, GENERAL NOTES, AND ABBREVIATIONS ELECTRICAL SCHEDULES ELECTRICAL SITE PLAN ELECTRICAL DEMOLITION PLAN - BLDG A ELECTRICAL DEMOLITION PLAN - BLDG C ELECTRICAL DEMOLITION PLAN - ROOF ELECTRICAL DEMOLITION ONE LINE DIAGRAM LIGHTING PLAN - BLDG A COMMONS LIGHTING PLAN - FIRST FLOOR BLDG B LIGHTING CONTROL ZONE PLAN - FIRST FLOOR BLDG B LIGHTING PLAN - SECOND FLOOR BLDG B LIGHTING CONTROL ZONE PLAN - SECOND FLOOR BLDG B LIGHTING PLAN - PARTIAL BLDG C GYM LIGHTING CONTROL ZONE PLAN - PARTIAL BLDG C LIGHTING PLAN - BLDG A ENTRY POWER PLAN - BLDG A POWER PLAN - FIRST FLOOR BLDG B POWER PLAN - SECOND FLOOR BLDG B MECHANICAL POWER PLAN - PARTIAL ROOF PLAN LDGGity of Tukwila MECHANICAL POWER PLAN - FIRST FLOOR BLDG B BUILDING DIVISION MECHANICAL POWER PLAN - SECOND FLOOR BLDG B MECHANICAL POWER PLAN - ROOF BLDG B MECHANICAL POWER PLAN - PARTIAL BLDG C SYSTEMS PLAN - BLDG A SYSTEMS PLAN - FIRST FLOOR BLDG B SYSTEMS PLAN - SECOND FLOOR BLDG B SYSTEMS PLAN - PARTIAL BLDG C ELECTRICAL DETAILS ELECTRICAL DETAILS ELECTRICAL ONE LINE DIAGRAM ELECTRICAL PANEL SCHEDULES REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1. 4 2018 CITY vs It Ii:d LA _NOV 022010 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com A Airni\ TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL LEGEND, GENERAL NOTES, AND ABBREVIATIONS Drawing Number E0.01 DEDICATED OUTDOOR AIR SYSTEM SCHEDULE EQUIPMENT TAG VOLTAGE/PHASE HP KW FLA MCA MOCP BRANCH CIRCUIT DISCONNECT RACEWAY PHASE N G SIZE FUSE NOTES AIR HANDLING AND HEAT RECOVERY DOAS-01 460/3 6.6 20 3/4" 3#12 #12 #12 30 20 1,3 DOAS-02 460/3 3/4' 3#12 #12 #12 30 20 1,3 DOAS-03 460/3 3/4" 3#12 #12 #12 30 20 1,3 DOAS-04 480/3 14.9 20 3/4" 3#12 #12 #12 30 20 1,3 VRF HEAT RECOVER BRANCH CIRCUIT CONTROLLER BC-1 208/1 5.7 - 3/4' 2#12 - #12 BC-2 208/1 5.7 3/4" 2#12 #12 MITSUBISHI CITY VRF OUTDOOR UNIT SCHEDULE ODU-1A 480/3 31.0 60 1" 3#4 #4 #10 60 60 1 ODU-2A 480/3 31.0 60 1" 3#4 #4 #10 60 60 1 ODU-2B 480/3 31.0 60 1' 3#4 #4 #10 60 60 1 MITSUBISHI CITY VRF INDOOR UNIT SCHEDULE FCU-B101 208/1 0.34 3.51 15 3/4" 2#12 #12 30 20 1 FCU-B102 208/1 0.06 1.05 15 3/4' 2#12 #12 30 20 1 FCU-B103 208/1 0.34 3.51 15 3/4" 2#12 #12 30 20 1 FCU-B104 208/1 0.34 3.51 15 3/4' 2#12 #12 30 20 1 FCU43105 208/1 0.06 1.05 15 3/4" 2#12 #12 30 20 1 FCU-B106 208/1 0.34 3.51 15 3/4' 2#12 #12 30 20 1 FCU-B107 208/1 0.34 3.51 15 3/4' 2#12 #12 30 20 1 FCU-B108 208/1 0.36 3.51 16 3/4" 2#12 #12 30 1 FCU-B201 208/1 0.17 3.51 15 3/4" 2#12 #12 30 20 1 FCU-B202 208/1 0.06 1.05 15 3/4" 2#12 #12 30 20 1 FCU-8203 208/1 0.34 3.51 15 3/4" 2#12 #12 30 20 1 FCU-B204 208/1 024 3.50 15 3/4' 2#12 #12 30 20 1 FCU-B205 208/1 0.17 3.51 15 3/4" 2#12 #12 30 20 1 FCU-B206 208/1 0.17 3.51 15 3/4" 2#12 #12 30 20 1 FCU-B207 208/1 0.24 3.50 15 3/4" 2#12 #12 30 20 1 FCU-B208 208/1 0.63 7.70 15 3/4" 2#12 #12 30 20 1 VRF HEAT RECOVERY UNIT SCHEDULE VHR-01 208/1 40 W 0.16 3/4" #12 #12 #12 30 16 1 VHR-02 208/1 40 W 0.16 3/4" #12 #12 #12 30 15 1 VHR-03 208/1 40 W 0.16 3/4" #12 #12 #12 30 15 1 VHR-04 208/1 40 W 0.16 3/4" #12 #12 #12 30 15 1 DEDICATED OUTDOOR AIR SYSTEM DOAS-01 208/3 29.4 40 3/4" 3#8 #8 #10 60 40 1 DOAS-02 208/3 25.1 35 3/4' 3#10 #10 #10 60 35 1 SPLIT SYSTEM AIR CONDITIONER SCHEDULE AC-1A, AC-1B, AC-1 C/CU-01 208/1 31.0 44 3/4" 2#8 #10 60 50 1 AC-02/CU-02 208/1 12.0 15 3/4" 2#12 012 30 15 1 AIR-COOLED CONDENSING UNIT SCHEDULE CU A01 480/3 0.34 49.00 60 - 4 CU-A02 480/3 0.06 49.00 60 4 CU-A03 480/3 0.34 32.00 50 4 CU-A04 480/3 0.34 63.00 80 4 CU-A05 480/3 - 0.06 63.00 80 4 CU-A06 480/3 - 0.34 63.00 80 • 4 CUA07 480/3 0.34 14.00 20 4 CU-A08 480/3 - 0.36 - 14.00 20 4 CU-A09 480/3 - 0.17 - 32.00 50 - • 4 GAS FIRED WATER HEATER SCHEDULE DWH-01 120/1 6.2 3/4" #12 #12 #12 2 DWH-02 120/1 6.2 3/4" #12 #12 #12 2 PUMP SCHEDULE DCP01 120/1 1/12 1.3 3/4" #12 #12 #12 2 PROPELLER FAN SCHEDULE PF-01 120/1 1/12 5.7 3/4" #12 #12 #12 2 PF-02 120/1 1/12 5.7 3/4" #12 #12 #12 2 ELECTRICAL WALL HEATER SCHEDULE EWH-01 208/1 14.5 20 3/4" #12 #12 #12 2 EXHAUST FAN SCHEDULE SK-01 120/1 1.4 3/4" #12 #12 #12 2 EF-1 120/1 1/4 NOTES 1. PROVIDE DISCONNECT SWITCH 3. MANUAL MOTOR STARTER 5. MAKE CONNECTION TO VFD INSTALLED BY OTHERS 8. EXTEND EXISTING CONDUIT AND CONDUCTORS TO NEW UNIT AS REQUIRED LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER MODEL DELIVERED LUMENS LAMP TYPE COLOR TEMP INPUT WATTS L# 4" RECESSED LINEAR SLOT. 0-10V DIMMING DRIVER (NOTE #1) PRUDENTIAL P43-LED35-SO-i'-TMW-AWL-D1R 900 / FT LED 3500 10W / FT LH1 4" RECESSED LINEAR SLOT. 0-10V DIMMING DRIVER, HARD CEILING PRUDENTIAL P43-LED3530.4'-TMW-SAL-D1 900 / FT LED 3500 1OW / FT D1 6" RECESSED DOWNLIGHT LITHONIA LDN4 SERIES 4509 LED 3500 42.8 P1 BFT. 4" HIGH PERFORMANCE DIRECT/INDIRECT PENDANT LIGHT FIXTURE. 9'-0" AFF MOUNTING FINELITE HP-4 SERIES 6134 LED 3500 113.6 P2 BET. LINEAR DIRECT/INDIRECT PENDANT MOUNT, 0-10V DIMMING DRIVER LUMIUM NITROGEN SERIES 720/FT LED 3500 8W / FT P3 16" ROUND PENDANT FIXTURE PRUDENTIAL P4000 SKY SERIES 3500 LED 3500 47 PHB CABLE HUNG 22" HIGH BAY LED UGHT FIXTURE, 27-0" AFF MOUNTING SPECTRUM LIGHTING PRX22LEDLX SERIES 15000 LED 3500 117 PHBE CABLE HUNG 22" HIGH BAY LED UGHT FIXTURE, 27-0"AFF MOUNTING, WITH BATTERY BACK SPECTRUM LIGHTING PRX22LEDLX SERIES 15000 LED 3500 117 R1 l'x4' RECESSED TROFFER. 0-10V DIMMING DRIVER FINELITE HPR SERIES 4509 LED 3500 42.8 R2 2'XZ RECESSED TROFFER. 0-10V DIMMING DRIVER FINELITE HPR SERIES 3958 LED 3500 42.8 R3 24" ROUND RECESSED FIXTURE PRUDENTIAL P4000 SKY SERIES 3500 LED 3500 47 S1 LED STRIP LIGHT LITHONIA ZL1D SERIES 3966 LED 3500 30 S2 4'X2' HIGHBAY LED FIXTURES LITHONIA IBE SERIES 18000 LED 4000 136 S3 16" X 18" SURFACE MOUNT CANOPY FIXTURES KENALL FL SERIES 2222 LED 4000 20 W1 E WALL MOUNTED LIGHT FIXTURE, MOUNTED AT 17-0' AFF, WITH BATTERY BACKUP UTHONIA WST LED P1 40K VF MVOLT E20WH 1639 LED 40000 15 W2E WALL MOUNTED LIGHT FIXTURE, MOUNTED AT 10'-0" AFF WITH BATTERY BACKUP LITHONIA WST LED P140K VF MVOLT E2OWH 1639 LED 40000 15 WL# 4"WALL MOUNTED LINEAR FIXTURE. 0-10V DIMMING DRIVER (NOTE #1) PRUDENTIAL P40-LED35-SO-#'-TMW-AWL-D1 R-WM 2700 LED 3500 28 NOTES: 1) # = DISTANCE IN FEET. REFER TO PLANS. ELi 8-095 1 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2018 City of Tukwila IDUILDING DIVISION r!i'4 NOV022018 PER!!•';!T CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com A Airni\ TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL SCHEDULES Drawing Number E0.02 COPYRIGHT © 2018 ROLLUDA ARCHITECTS, INC. -c) • L F- I DING 2-i ORY i I J 200A BUSSED GUTTER ATS'Z' PNL'1P2' XFMR T-1 P2' DIST. 'OP-B' w V GEN 0 TOR 0 0 I � , ELECTRICAL PARTIAL SITE PLAN ' / SCALE: 1' =10'-0' F PNL'127 -If 1E) 1 l V • \\\ \\ \\`\\\ \\\ \ \\.. \\ \ • • O a O GENERAL NOTES 1. LOCATE SERVICES PRIOR TO ANY TRENCHING. 2. SEE ONE LINE DIAGRAM FOR CONDUCTOR SIZES AND QUANTITIES. PLAN NOTES PROVIDE 2" UNDERGROUND CONDUIT FROM GENERATOR TO BUSSED GUTTER IN ELECTRICAL ROOM. PROVIDE 1" UNDERGROUND CONDUIT FROM PANEL IN ELECTRICAL ROOM TO OFFICE ADDITION. PROVIDE (2) 3' UNDERGROUND CONDUITS FROM MAIN SWITCHBOARD IN BUILDING A ELECTRICAL ROOM TO NEW BUILDING B DISTRIBUTION PANEL 'DP-B'. PROVIDE 2" UNDERGROUND CONDUIT FROM ATS 'Z' IN BUILDING B ELECTRICAL ROOM TO WALL OF BUILDING A THEN UP WALL TO CEILING SPACE OF FOOD STORAGE ROOM A177 TO NEW PANEL '1Z2' IN MECH/BOILER ROOM A179. ELi 8-095 1 REVIEWED FOR COMPLIANCE WITH NFPA70-NEC NOV 1 4 2018 City of -Tukwila BUILDING DIVISION C; I A! � .........:,:? f �'.. NUV 02 2018 PERM3T CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com IiiCt TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 00 0 2 1- I- � W w e N H. w co 0 w o0 0 Z o o Q c0 N J<O 1—CC. $�°° °r 2< 0 1 Q rn' co Y O O !g g goo- I— V J <'t 12 CV o I-' I- W u v l— o F'- a F- I— LL REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL SITE PLAN Drawing Number EI.O1 GENERAL REFERENCE NOTES: 1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION. rolluda architects l (E)BO-02 (E)BO-01 (E)EF-Al2 (E)CAF-A01 J r\ V -�-- .-_ L (E) COMMONS/CAFETERIA A148 ELECTRICAL DEMOLITION PLAN - PARTIAL BLDG A \ / SCALE: 118'=1'-0' (3,4 1 I J ELECTRICAL DEMOLITION PLAN - BLDG A 2ND FLOOR SCALE: 118' = 1'-0' _9 F—`�: A155 tr 1 I i irT ny �I I II ' ---�, 1 I L--- �1ur--'—ar! —' — Sir rl --- 11 r -1 (TYPICAL OF 4) ELECTRICAL DEMOLITION PLAN - BLDG A ENTRY SCALE: 118' =1'-0' 2. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO OTHERWISE BY THE OWNER. 3. DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL INSTALLATION AS INDICATED. THIS INCLUDES, BUT IS NOT LIMITED TO LIGHT FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, ETC. 4. REMOVE CONDUIT, WIRE, BOXES AND FASTENING DEVICES AS REQUIRED TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION. CONDUIT IN AREAS NOT EXPOSED IN THE COURSE OF THE WORK SHALL BE ABANDONED AND CAPPED AT BOTH ENDS. 5. RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE RENOVATIONS YET REQUIRED FOR CONTINUED SERVICE. COORDINATE WITH OWNER PRIOR TO INTERRUPTIONS AND RECONNECTIONS. 6. WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENING, ETC.) RESULTS IN THE REMOVAL OF DEVICES, DISCONNECT OR RECONNECT AS REQUIRED ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT SYSTEM. 7. REMOVE ALL EXISTING LIGHTING FIXTURES AND POWER SYSTEMS AS INDICATED OR REQUIRED TO CLEAR AREA FOR NEW INSTALLATION. 8. REMOVE ALL CONDUCTORS, CONDUIT AND SURFACE RACEWAYS ASSOCIATED WITH DEVICE REMOVAL. 9. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL. 10. REMOVE CONDUCTORS, CONDUIT, AND RACEWAYS THAT ARE NO LONGER IN USE. DEMOLITION PLAN NOTES: a a a O 0 a O O a 10 ALL FIRE ALARM DEVICES IN THIS AREA TO BE REMOVED. REMOVE CONDUIT AND CABLING BACK TO SOURCE. EXISTING LIGHT FIXTURES TO BE REMOVED AND RELOCATED. MAINTAIN EXISTING CONDUIT AND CONDUCTORS AND EXTEND TO NEW LOCATOIN. SEE LIGHTING SHEET E2.51 FOR NEW LOCATION. EXISTING CIRCUITS K-1, K-15, K-17, K-19, K-26,28,30, K-31 FEEDING COOLER, FREEZER, REFRIGERATOR, OR REFRIGERATOR SYSTEM TO BE INTERCEPTED AND EXTENDED TO NEW PANEL '1Z2'. SEE NEW POWER PLAN ON SHEET E3.11 FOR NEW PANEL LOCATION. EXISTING LIGHT FIXTURES TO BE REMOVED. CONDUIT AND CONDUCTORS TO REMAIN AND BE REUSED. EXISTING CARD READER TO BE REMOVED. CONDUIT AND CONDUCTORS TO REMAIN AND BE REUSED. EXISTING ADA PUSH BUTTON TO BE REMOVED. CONDUIT AND CONDUCTORS TO REMAIN AND BE REUSED. EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. CORRESPONDING DISCONNECT, CONDUIT, AND CONDUCTORS TO REMAIN AND BE RE -USED TO FEED NEW MECHANICAL UNIT IN SAME LOCATION. REMOVE EXISTING FIRE ALARM CONTROL PANEL. CONDUIT AND CABLING TO REMAIN AND RECONNECT TO NEW FIRE ALARM CONTROL PANEL. REMOVE ALL ELECTRICAL DEVICES, LIGHT SWITCHES, LIGHT FIXTURES, FIRE ALARM DEVICES, AND SYSTEMS DEVICES ON CEILING IN THIS AREA. REMOVE ALL ELECTRICAL DEVICES, LIGHT SWITCHES LIGHT FIXTURES, FIRE ALARM DEVICES, AND SYSTEMS DEVICES ON WALL TO BE REMOVED IN THIS AREA. -D ,AA REVIEWED FON COMPLIANCE WIT1h NFPA 70 - NFr NOV 14 2018 City of Tukrvilz. BUILDING DIVISION ELi 8-095 1 CiTY NUY022018 PERMIT CENTER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J 0 0O ''I— CD VJ VJ J J 00 02CC W'' ^^ VJ z <QO 00 VJ < I- f22 rn w ccQD o tv ® co co of 0 r r - co 2 ® _coS < V = Q O1 p J_ Ugrc m Y w aF0 REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL DEMOLITION PLAN - BLDG A Drawing Number EDI.O1 COPYRIGHT 0201S ROLLUDA ARCHITECTS. INC. GENERAL REFERENCE NOTES: rolluda architects r L n r 0 1 JJJ (E) GYMNASIUM LC1051 w 0 w 0 ELECTRICAL DEMOLITION PLAN - BLDG C SCALE: 11B' =1.-0' A.. I I I LJ -n_ Y n f V Cr- 3 1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION. 2. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO OTHERWISE BY THE OWNER. 3. DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL INSTALLATION AS INDICATED. THIS INCLUDES, BUT IS NOT LIMITED TO LIGHT FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, ETC. 4. REMOVE CONDUIT, WIRE, BOXES AND FASTENING DEVICES AS REQUIRED TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION. CONDUIT IN AREAS NOT EXPOSED IN THE COURSE OF THE WORK SHALL BE ABANDONED AND CAPPED AT BOTH ENDS. 5. RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE RENOVATIONS YET REQUIRED FOR CONTINUED SERVICE. COORDINATE WITH OWNER PRIOR TO INTERRUPTIONS AND RECONNECTIONS. 6. WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENING, ETC.) RESULTS IN THE REMOVAL OF DEVICES. DISCONNECT OR RECONNECT AS REQUIRED ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT SYSTEM. 7. REMOVE ALL EXISTING LIGHTING FIXTURES AND POWER SYSTEMS AS INDICATED OR REQUIRED TO CLEAR AREA FOR NEW INSTALLATION. 8. REMOVE ALL CONDUCTORS, CONDUIT AND SURFACE RACEWAYS ASSOCIATED WITH DEVICE REMOVAL. 9. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL. 10. REMOVE CONDUCTORS, CONDUIT, AND RACEWAYS THAT ARE NO LONGER IN USE. DEMOLITION PLAN NOTES: O ALL FIRE ALARM DEVICES IN THIS AREA TO BE REMOVED. REMOVE CONDUIT AND CABLING BACK TO SOURCE. ELi 8-095 1 REVIEWED FOR COMPLIANCE WITH NFPA70-NEC NOV 14 2016 City of Tukwila [BUILDING DIVISION .. i^. t �1 i1... ••LL/ sl i" I :i '.'.. NOV 02 2018 PEReM T CENTER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com A Alvin.% TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J HO UO ce U co CD cat JD O0_ O� Z <QO SOD ova REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRIFCAL DEMOLITION PLAN - BLDG C GYM Drawing Number ED1.02 COPYRIGHT ID 201E ROLLUDA ARCHITECTS. INC. GENERAL REFERENCE NOTES: DEMOLITION PLAN NOTES: BUILDING B CU-B01 0 CU-A06 0 CU-A05 CU-A04 I CU-A08 CU-A07 1. VISIT AND EXAMINE THE SITE PRIOR TO INITIATION OF WORK TO ASCERTAIN THE CONDITIONS AND LIMITS OF DEMOLITION AND CONSTRUCTION. 2. DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO OTHERWISE BY THE OWNER. 3. DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL INSTALLATION AS INDICATED. THIS INCLUDES, BUT IS NOT LIMITED TO LIGHT FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, ETC. 4. REMOVE CONDUIT, WIRE, BOXES AND FASTENING DEVICES AS REQUIRED TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION. CONDUIT IN AREAS NOT EXPOSED IN THE COURSE OF THE WORK SHALL BE ABANDONED AND CAPPED AT BOTH ENDS. 5. RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE RENOVATIONS YET REQUIRED FOR CONTINUED SERVICE. COORDINATE WITH OWNER PRIOR TO INTERRUPTIONS AND RECONNECTIONS. 6. WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENING, ETC.) RESULTS IN THE REMOVAL OF DEVICES, DISCONNECT OR RECONNECT AS REQUIRED ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT SYSTEM. 7. REMOVE ALL EXISTING LIGHTING FIXTURES AND POWER SYSTEMS AS INDICATED OR REQUIRED TO CLEAR AREA FOR NEW INSTALLATION, B. REMOVE ALL CONDUCTORS, CONDUIT AND SURFACE RACEWAYS ASSOCIATED WITH DEVICE REMOVAL. 9. COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES WITH ARCHITECTURAL. 10. REMOVE CONDUCTORS, CONDUIT, AND RACEWAYS THAT ARE NO LONGER IN USE. /27 fil ,,, ,/�' i I1 IL ELECTRICAL DEMOLITION PLAN - ROOF ALT C SCALE: V18•=1'•0• ral II i CU-A03 CU-A02 0 0 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. CORRESPONDING DISCONNECT, CONDUIT, AND CONDUCTORS TO REMAIN AND BE RE -USED TO FEED NEW MECHANICAL UNIT IN SAME LOCATION. ELi 8-095 1 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2010 City of Tukwila BUILDING DIVISION Cm yr -I ;:11.1: NUV 02 2018 PE ?!'iT CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com in't‘ ttit TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409.7315 Phone: 253.472.3300 www.treswest.com J 0 U0 cc U co w o Jo O o O N2 I.L w co <<00 00 ova I— tu co • O � oe tom =Q REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL DEMOLITION PLAN - ROOF Drawing Number EDI.03 CIRCUIT LEGEND 1+, 2W+G (3 WIRES TOTAL) 3#, 4W+G (5 WIRES TOTAL) CKT ID RACEWAY/WIRE CKT PM CKT ID CONDUIT AND WIRE BPS (A2] 3/4'C, 2#12, #12G 20 [A4] 3/4'C, 4#12, #12G 20 (82] 3/4'C, 2#10, #10G 30 [841 3/4'C, 4#10, #10G 30 [C2] 3/4'C, 2#8, #10G 40 (C41 l'C, 4#8, #10G 40 [D2] 3/4"C, 2#6, #10G 50 (04] VC, 4#6, #10G 50 [E2] 1'C, 244, #10G 60 [E4] 1-1/4"C. 4#4. #10G 60 [F2] 1'C, 244, #8G 70 [F4] 1-1/4'C, 4#4, #8G 70 [G2] 1-1/4'C, 2#2, #8G 60 (G4) 1-112'C, 4#2, #eG 80 (H2] 1-1/4'C, 2#2, #8G 80 (H4] 1-l/2t, 4#2, #86 90 [J2] 1-114"C, 2#1, #8G 100 (J4) 2'C, 4#1, #8G 100 [K2] 1.1/4'C, 201, #6G 125 IK41 2'C, 4#1, #6G 125 IL21 1-1/4'C, 2#1/0, #6G 150 (L4] 2'C, 4#1/0, #6G 150 [M21 1-1/2'C, 2#2/0, #6G 175 (M4) 2'C, 4#2/0, #6G 175 [N2] 1-1/re. 2#3/0, #6G 200 PM) 2'C, 403/0, #6G 200 [02] 2'c, 2#410, #4G 225 (04] 2-1/2"C, 4#4/0, #46 225 [P2] 2-1/2'C, 2-250KCM, #4G 250 [P41 at, 4-250KCM, #4G 250 [Q2] 2-1/2"C, 2-350KCM, #4G 300 (04) at, 4-35OKCM, #4G 300 [112] 2-SETS [2'C, 243/0, #3G] 400 (R4] 2-SETS [2-1/2'C, 4#3/0, #3G] 400 3+, 3W+G (4 WIRES TOTAL) [54] 2-SETS (3'C, 4-250KCM, #2G] 500 CKT ID CONDUIT AND WIRE !NAPS (T4] 2-SETS (3'C, 4-350KCM, #1G] 600 [A3] 3/4t, 3#12, #12G 20 N4) 2-SETS [4"C. 4-500KCM. #1/0G] 700 [83] 3/4'C, 3#10, #10G 30 [V4] 3-SETS [3"C. 4-300KCM, #110G] 800 (C3) 3/4t, 3#8, #10G 40 [W4) 3-SETS 14"C. 4-500KCM, #2/061 1000 [D3] VC. 3#6, #10G 50 [X4] 4-SETS (3'C, 4-350KCM, #3/0G) 1200 (E3] 1"C. 3#4, #10G 60 [Y4) 4-SETS (4'C, 4S00KCM, #4/0G] 1600 1F3] 1-1/4"C, 3#4, #8G 70 [Z41 5-SETS (4'C, 4-600KCM, 250KCM G) 2000 [G3) 1-1/4"C. 3#2. #8G 80 480VA, 3+, TRANSFORMER PRIMARY (3W+G) [H3] 1-1/4"C, 3#2, #8G 90 CKT ID CONDUIT AND WIRE CKT AMPS (J3] 1.1/2"C, 3#1, #8G 100 (30H] 1'C, 3#4, #10G 60 (K3) 1-1/2"C, 3#1, #6G 125 (45111 1.1/2"C. 3#1, #8G 100 (L3) 1-lr2t, 3#1/0, #6G 150 [75H] 1-1/2'C, 3#1/0, #6G 150 [M3] 2"C, 3#2/0, #6G 175 [112H] 2'C. 3#3/0. #6G 200 [N3] YC, 3#3/0, #6G 200 [150H] 2-112t, 3-250KCM, #4G 250 [03] 2t, 3#4/0, #4G 225 [2254 2-SETS [2'C, 3#3/0, #3G] 400 (P3) 2-1/2'C, 3-250KCM, #4G 250 [300H] 2-SETS (3"C, 3-350KCM, #1G) 600 [Q3] 2-1/2'C, 3-350KCM, #4G 300 [500H] 3-SETS [3'C, 3-300KCM, #1/0G] 800 (R3] 2-SETS (2'C. 3#3/0, #36] 400 [750H] 4-SETS [3'C, 3-350KCM, #3/0G] 1200 [S3] 2-SETS 12-1/2'C, 3-250KCM, #2G] 500 208Y/120V, 3+, TRANSFORMER SECONDARY (4W+G) rr3] 2-SETS (3'C, 3-350KCM, #1G1 600 CKT ID CONDUIT AND WIRE CKT AMPS [U3] 2-SETS (3'C, 3-500KCM, #1/0G] 700 [30L] 2'C, 4#1, #6G 100 (V3] 3-SETS (3'C, 3-300KCM. #1/0G] 800 (45L] 2-C, 4#1/0. #6G 150 IW3] 3-SETS (3'C, 3-500KCM, #2/0G] 1000 [75L] 2-1/2'C, 4#4/0, #2G 225 (X3] 4-SETS (3"C. 3-350KCM, #3/0G] 1200 [112L] 2-SETS [2-1/2'C, 403/0, #1/0G) 400 D'3] 4-SETS (4"C. 3-600KCM, #4/0G1 1600 [150L] 2-SETS [3'C. 4-350KCM, #2/OG] 600 [Z3] 5-SETS [4'C, 3-600KCM, 250KCM G] 2000 [225L] 3-SETS [3'C, 4-300KCM, #2/0G] 800 3+, 4W+G (6 WIRES TOTAL) (200% NEUTRALS) [300L1 3-SETS [4'C, 4-500KCM, #3/06] 1000 [2E4] 1-1/2'C, 34/4, 2#4N, #8G 60 [500L] 4-SETS [4'C, 4-600KCM, #4/OG) 1600 [2N4] 3'C. 3.250KCM. 2-250KCM N. #1/0G 200 [750L] 6-SETS 14'C, 4S00KCM, 250KCM G] 2500 12R4] 2-SETS 13'C, 3-250KCM, 2-250KCM N. #1/0G] 400 [2T4] 2-SETS [CC, 3-500KCM. 2-500KCM N. #2/0G) 600 [2V41 3-SETS [3-1/2'C. 3-400KCM, 2-400KCM N. #3/0G] 800 TO UTILITY TRANSFORMER (E)PA (E)PA (E)PA 208/ 208/ 208/ 120V 120V 120V SEC 1 SEC 2 SEC 3 XFMR (E LA 480/ 277V (3)300 AF 400/3 1 r I I I I (E)PBT r(E )C 1 208/ 208/ 1 120V 120V I 1 L___J L 200A ENCLOSED CIRCUIT BREAKER 1600A BUS TRANSFORMER TE (E)PC 208/ 120V SEC 1 (E)PC 208/ 120V SEC 2 480/ 277V (E PE 208/ 120V (3)200 AF 200/3 D�4 (3)400 AF (3)175 AF "(3) 00 AF (3)600 AF 151 I 400/3 200/3 2 100/3 7 600/3 I .1 /, 1 TRANSFORMER TF (E PD (E)PD (E)C2 208/ 208/ 208/ 120V 120V 120V SEC 1 SEC 2 400A BUS-\ 400A ENCLOSED CB (E)K 208/ 120V SEC 1 (E)K 208/ 120V SEC 2 XFMR (E)TK 480/ 277V (3)200 AF 200/3 (E PF 208/ 120V 100A SPARE (E) DISTRIBUTION PANEL' DP' 208/ 120V 60A SPARE 60A SPARE (3)100 AF C, (3)60 AF ( (3)60 AF 100/3 / 60/3 / 60/3 I I (E)MP 208/ 120V (E)M (E)M (E)M 480/ 480/ 480/ 277V 277V 277V SEC 1 SEC 2 SEC 3 (E)MAIN SWITCHBOARD ELECTRICAL DEMOLITION PARTIAL ONE LINE DIAGRAM NTS XFMR (E)TM 4-60A SPACE 4- 400A SPACE }- 200A SPACE F 200A SPACE 4-100A SPACE GENERAL NOTES 1, REFER TO PANEL SCHEDULES, SHEETS EX.XX - EX.XX, AND LIGHTING CONTROL PANEL RELAY SCHEDULES, SHEET EX.XX. DEMOLITION PLAN NOTES 0 EXISTING PANEL TO BE REMOVED. REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE. D2 EXISTING TRANSFORMER TO BE REMOVED. REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE. EXISTING SWITCH AND FUSES TO REMAIN. 0 EXISTING CIRCUIT BREAKER TO REMAIN AND BE REUSED TO FEED NEW PANEL IN BLDG A COMMONS. SEE SHEET E3.11 FOR EXACT LOCATION. 0 EXISTING SWITCH AND FUSES TO REMAIN. ELi 8-095 1 REVIEWED FOR - COMPLIANCE WITH NFPA70-NEC NOV 14 2018 City of Tukwila BUILDING DIVISION I nC /1/f]'-'• ..YS"�-iva... NUV 02 2018 rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com ittnn% 11/4 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com H 0 I..t� co 0 J 0 2 0 co J_ D H REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL DEMOLITION ONE LINE DIAGRAM Drawing Number EDI.04 PEIU.17 C:EilTER LIGHTING CONTROL ZONES: GENERAL NOTES 1. PROVIDE UNSWITCHED CURRENT CARRYING CONDUCTOR TO ALL EMERGENCY LIGHT FIXTURES. PLAN NOTES EXTEND CONDUIT AND CONDUTORS TO RELOCATED LIGHT FIXTURES. rolluda architects yI I e I e• at •• m a. - 'MANUAL ON' OCCUPANCY SENSOR ZONE LIGHT FIXTURES IN ROOM CONTROLLED VIA 'MANUAL ON' / 'AUTOMATIC OFF' LOW VOLTAGE LOCAL OCCUPANCY SENSOR(S). NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE: WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. DAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 -10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS = 50fc = 35fc = 15fc DAYLIGHTING ZONE 2 (SECONDARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). B. FOOTCANDLE SETPOINTS: BA. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS LL _LL Lam. LL LL LL LL I '1 LL LLL-LLL L4L. L = 50fc 35fc = 15fc LL LLL LLL LLLL LLL LLL LLL LLL L LLLL LLLL LLLL I I I I TIME CLOCK AND OCCUPANCY ZONE • • LIGHT FIXTURES ENABLED/DISABLED VIA TIMECLOCK PER C405.2.2.1 AFTER HOURS LIGHT FIXUTURES WILL BE AUTOMATIC ON VIA 2-HOUR OVERIDE SWITCH LOCATED AT ACCESSIBLE LOVATION. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE: • WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. ei PAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS DAYLIGHTING ZONE 2 (SECONDARY) A. B. B.A. B.B. B.C. = 50fc = 35fc = 15fc DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0- 10V). FOOTCANDLE SETPOINTS: LAB SPACES NON -LAB CLASSROOMS AND OFFICES CORRIDOR/ COMMON AREAS = 50fc = 35fc = 15fc LOCAL LINE VOLTAGE SWITCH ZONE JELECTRICAL/TELECOMMUNICATIONS ROOMS) • LIGHT FIXTURES IN EACH ROOM CONTROLLED VIA LOCAL LINE VOLTAGE SWITCH. • NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. DASHED OUTLINE REPRESENTS AFTER HOURS OVERIDE ZONF (CORRIDORS/LOBBY) • SWITCH SHALL ENABLE ALL RELAYS CONTROLLING FIXTURES WITHIN ZONE Ltt - LLL LLLj_ LLLLL LL;L, LLLLLLLL\ L"LL►® LL LLLLL LLL L L.LLLLLL LLLLLL _ LIJ LLLLLLLLLLLL�'. LULL L`r L• LLLLL,LLLLLLLLL\ LI L tTL LLL LL L,LLLLLL—LLLL I I I LLB- LLLL��LLL IL LLLLLL LLLLL'L LLLLLILLLLLL LLLLLLLLLLLLLLLULLLLLLLLLL (J I_ �J LLLL1 L.LLLLLLLULLLLLLtLLLLL LLfL I LLLLILL.LLLLLLLLI__L Ll_LL_LLLLLLL $_LLLL 'LLLLLL LLLLLitTffit LIGHTING CONTROL ZONE FLOOR PLAN - BLDG A SCALE: 1/B' =11-0' 1 CAG) (E)ST A146, 403 a •PHBE a OPHB a OPHB a OPHB a OPHB a COMMONS A14 PHBE a OPHB a (E) 0 0 OPHB a OPHB a LIGHTING FLOOR PLAN - BLDG A SCALE 1B' = 1'.0' •PHBE a A4.7 a • (E) p 2. COORDINATE EXACT MOUNTING LOCATION OF ALL LIGHT FIXTURES WITH ARCHITECTURAL PRIOR TO ROUGH -IN. 3. SEE LIGHTING CONTROL DETAILS ON SHEET E6.02. ELi 8-095 1 CITY OF iLiic,v11.1& NUV 02 2018 PERM~`;T CENTER REVIEWED FOR COMPLIANCE WITS', 0-NFC NOV 14 2018 City of Tukwila BUILDING DIVIEIt`:' architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com 44-Mc S WEST DIMMERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA98409.7315 Phone: 253.472.33C0 www.treswest.com J 1— 0 U O re 1—U a J J o O 0 O 2 U� w Q YO I— co 4626 S. 144TH STREET re co ▪ 1— wco cc co 0 CO m WI 5 ",1 co 0 NvENL z w Y _i � o Hv FHU. REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING PLAN - BLDG A Drawing Number E2.11 0 E KEYPLAN GENERAL NOTES PLAN NOTES ROUTE THRU LIGHTING CONTROL PANEL. 10/17,2018 8:38:53 AM R2 a 1144 L4 INV1-2 R2 0 R2 INV1-1 c 11011L4-1 P1 q i SCIENCE LAB I \ 1L4-5B1Ci3 a R2 ' a 1 a 0L4_1 4 NV1-2 V ll R2 1L4-1---- 1 R1 1 L4-1 n R2 1L4-1 k R2 1L4-1 k R2 INV1-1 k R2 INV1-, I R2 1L4-1 p R1 1L4-1 R2 1L4-1 R2 R2 a1L41 a 1L4-1 j SCiENCt: LAB 13 04 R2 INV1-1 R2 1L4-1 18) — c X 11 1L4-1 R2 INV1-1 a it R2 INVt-1 _1 0 •D1 1L L9 1L4-1 h L9 1L4-5----- L4 INV1-2 L7 1L45 SHARED SPACE 1L4-5 B•100 L4 INV1-2 D, EI 1L4-5 R2 ---� ❑0 1L4-1 I O 11L41 d SCIENCE R2 1L4-1 9 R2 4NV1--t -- r SCIENCE PREP B106 R1 1L4-1. R2 INV1-1 9 LIGHTING FLOOR PLAN - FIRST FLOOR BLDG B SCALE. 1B'=1-O LAB C3102 OD R2 rigINV1-1 1L4-5 L4 IN IlI INV,-2 II R2 a1L41 b 1 W1E • X 1L4-5 L9 1L4-5 L4 INV1-2 I L9 4- 1L4-5 L10 1L4-5 L4 S1 INV1-2 .I I ' S1 L9 1 —0-I 1L4-5 $LV L4 NV1-2 9 fl L9 1L45 L4 INV1-2 INV1-2 L9 1L4-5 L4 INV1-2 X 1L4-5 R3 INV1-2 0 -«0VEST-' 13100A CDC] Ij_. II w1E i ors S3 \ 0083\ 'I l� to e X 1L4.3 0 0 1 P1 1L4-3 e P1 1L4-3 b P1 INV1-1 a vs R1 1L4-3 h t 0 i.: R1 1L4-3 h 0 P1 INV1-1 f P1 1 L4-3 c 0 P1 1 L4-3 a 0 Oj 9W1E P1 ILA-3 9 P1 1L 3 d1 $ vs R1 R1 1L4-3 • 1L43 i o LH_, _ GIRLS LH, L23 `NV1-1 RES fROOM 1L4-3 1L4-3 ti 1L4-3 a , VS$i MECHANICAL/ I 0 E JEC!CL1 To S1 — - S1 1L4-3B105 1L43 I I P1 INv1-, -CREATIVE- LEARNING LAB B101 P1 1L4-3 0 0 R1 o -J H' W2E 0 R1 1L4-3 P1 P1 9 1L4-3 IN1(1-i m m i P1 1L4-3 0 P1 P1 1L4-3 INV1-1 r q P11 0 H� W2E CD 0 J r m(NJ W zw II (.) 0) 2w 1. PROVIDE UNSWITCHED CURRENT CARRYING CONDUCTOR TO ALL EMERGENCY LIGHT FIXTURES. 2. COORDINATE EXACT MOUNTING LOCATION OF ALL LIGHT FIXTURES WITH ARCHITECTURAL PRIOR TO ROUGH -IN. 3. SEE LIGHTING CONTROL DETAILS ON SHEET E6.02. ELi 8-095 1 ;BE) BA 1 AC ) 0 0 MASTER OVERIDE SWITCH FOR CORRIDOR FIXTURES. -t-, . :.. . r. .:ItS NUV 02 2010 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 4 201i1 City of Tukwila. BUILDING DIVIS'fltt rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST ENGINEERS. INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: AH Drawn: AH Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING PLAN - FIRST FLOOR BLDG B Drawing Number E2.21 PERM:T CENTER KEYPLAN LIGHTING CONTROL ZONES: BB1 E3-3D 62 Q3-14 I I i $o••® =• S•i i-i-•�•1�o.�.�E 1011$a a •i••V1• •iii•;•1•i4•1•;1 00000004.0041000404 ass -aa� ads -��r� s a�.a 81 i�-a►�� 6i�i�iw •�i�4v4i wsw' ••••a�►••••rra ':•rra"4rr& )W V VgjV4VGi®•V•VOe$ —• 1r8mow-s-�11111� ifeettallaitimai ce f 4 • 1...,•• tore: •• el + 4 I + I +:10111 Poe, b13•:C•S ' • • o lt=•�•0•0•�•�•1•1•1•i•!�� 61 - • e u!sidegitiessiessawszteara Ay co LIGHTING CONTROL ZONE FLOOR PLAN - FIRST FLOOR BLDG B SCALE: 1A1': Pfi BB ELi 8-095 1 -LLLL -LLLL .LLLL -LLLL I I I I I I L___J 'MANUAL ON' OCCUPANCY SENSOR ZONE • • LIGHT FIXTURES IN ROOM CONTROLLED VIA 'MANUAL OM / 'AUTOMATIC OFF LOW VOLTAGE LOCAL OCCUPANCY SENSOR(S). NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. WHFRE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE: • WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. DAYLIGHTING ZONE 1 (PRIMARY) A B. B.A. B.B. B.C. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). FOOTCANDLE SETPOINTS: LAB SPACES NON -LAB CLASSROOMS AND OFFICES CORRIDOR/ COMMON AREAS = 50fc = 35fc = 15fc DAYLIGHTING ZONE 2 (SECONDARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - WV). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS TIME CLOCK AND OCCUPANCY ZONE • = Soft = 35fc = 15fc LIGHT FIXTURES ENABLED/DISABLED VIA TIMECLOCK PER C405.2.2.1 AFTER HOURS LIGHT FIXUTURES WILL BE AUTOMATIC ON VIA 2-HOUR OVERIDE SWITCH LOCATED AT ACCESSIBLE LOCATION. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIREQ BY CODE: • WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. I' a� DAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0-10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS = Soft = 35fc = 15fc DAYLIGHTING ZONE 2 (SECONDARY) A DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 —10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES = Soft BB NON -LAB CLASSROOMS = 35fc AND OFFICES B.C.CORRIDOR! COMMON ARFAS = 15fc LOCAL LINE VOLTAGE SWITCH ZONE JELECTRICAL/ TELECOMMUNICATIONS ROOMS) • LIGHT FIXTURES IN EACH ROOM CONTROLLED VIA LOCAL LINE VOLTAGE SWITCH. NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. DASHED OUTLINE REPRESENT S AFTER HOURS OVERIDE ZONE JCORRIDORS/LOBBY) • SWITCH SHALL ENABLE ALL RELAYS CONTROLLING FIXTURES WITHIN ZONE REVIEWED FOR COMPLIANCE WITH NFPA7O- NEC NOV 1 4 2018 City of Tukwila BUILDING DIVISION CITY OI"•i t4t:'ii:LA NUV 02 2018 rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com 44-11V— TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: Drawn: Checked: Project No. AH AH RA 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING CONTROL ZONE PLAN - FIRST FLOOR BLDG B Drawing Number E221A PERIVIIT CENTER BB1- CI R2 1L4-2 CI RP •P 1L4-2 a R2 1L4-2 MATH CLASSROOM B2flF rR2 INVi-3 EDR2 1L4-2 R2 1L4-2 1111 R2 1L4-2 R2 1L4-2 MATH CLASSROOM D206 aR2 OD ir R2 1L4-2 INV1-3 0 R2 1L4-2 6 R2 1L4-2 MATH CLASSROOM B204 4® INV1-3 2 El R2 1 L4-2 X WL4 1L4-6 INV14 CIR2 1L4-2 R2 INV1-3 X 1L4-2 LD® CIR2 ® 1L4-2 WL12 1L4-6 WL4 R2 INVi-3 INV14 0 R2 1 L4-2 X I L4-2 ®�$ C3R2 1L4-2 WL4 INV14 1L 1L4a 2 R2 ® 1L4-2 C3R2 1L4-2 WL12 1L4.6 WL4 INV14 R2 INV1-3 X 1L4-2 LD$ WL4 NV14 WL12 1L4-6 CIR2® a R2 ' 1 L4-2 1L4-2 WL4 INV14 WL4 INV14 MATH CLASSROOM sin B202 R2 INV1-3 CI.0'InR2 ® 1L4-2 INV1-3 CIR2 1L4-2 X 1L4-2 flLIGHTING FLOOR PLAN - SECOND FLOOR BLDG B MALE IIC = I'4r P2 INV14 WL12 I 1L4-6 WL4 INV14 SHARED SPACE // 1L B200 H/ "� INV14 P2 INV14 P2 INV14 X 1L4-6 LH1 INV1-3 vss 0 -EA INV14X INV1-3 WL4 INV14 WL9 1L4-6 WL4 INV14 INVI-3 ROOM P1 INV1-3 S1 Si 1L4-4 1L44 LH1 u' r--INV1-3 INV141 L23 1L4-4 L7 1L4-6( I L11 I 1 L4-6 •r3 0 R2 1L4-6 P1 1L4-4 4.011. P1' 1L4-4 ,E KILN $v 8215 1 0 1 0 S1 S1 1L4-4 1L4-4 o BOYS LHI INVI-3i ES I RG M S1 INVi-3 S1 INV1-3 13209 51 INV1-3 0 R2 INV1-3 MATii CLASSROOM B201 0 R2 1 L44 InR2 INVi-3 0 0 VS$ 0 R1 I L4-4 1 0 RI 1 L4-4 1L4-4 R2 1 L44 BC GENERAL NOTES 1. PROVIDE UNSWITCHED CURRENT CARRYING CONDUCTOR TO ALL EMERGENCY LIGHT FIXTURES. 2. COORDINATE EXACT MOUNTING LOCATION OF ALL LIGHT FIXTURES WITH ARCHITECTURAL PRIOR TO ROUGH -IN. 3. SEE LIGHTING CONTROL DETAILS ON SHEET E6.02. ELi 8-095 1 PLAN NOTES 0 MASTER OVERIDE SWITCH FOR CORRIDOR FIXTURES CII I 'JI"-Iii11f�riL:: NOV 02 2018 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 4 2018 !City ofi kt'ial BUILDING DIVISION rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com A Arni\ likot 7RES W1EST MINERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Pixie: 253.472.3300 wNM1V.tre'swest.corn 4626 S. 144TH STREET I— U a o Wco - o co O co 0, c9 th i�o rg §� O F�HI-LL REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING PLAN - SECOND FLOOR BLDG B Drawing Number E2.22 PERIt.`1:T CENTER KEYPLAN E LIGHTING CONTROL ZONES: rolluda architects ) T L L L !r-- LL L • L L L IkL. LL LL LL LL'•L' LLI4L LL LL LLLLL LLL L LLL L LLL L LLL L LL Je L L LLL LLL LLL LLL LLL LLL LLL LLL LLL LLL LLLL S 4, 441411101111 r ELi 8-095 1 Nee nsa CELL . LLLL -LLLL . LLLL 'MANUAL ON' OCCUPANCY SENSOR ZONE LIGHT FIXTURES IN ROOM CONTROLLED VIA 'MANUAL ON' / 'AUTOMATIC OFF' LOW VOLTAGE LOCAL OCCUPANCY SENSOR(S). NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE: WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. cits pAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 -10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS DAVI IGHTING ZONE 2 (SECONDARY) A. B. B.A. B.B. B.C. = 50fc = 35fc =15fc DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). FOOTCANDLE SETPOINTS: LAB SPACES NON -LAB CLASSROOMS AND OFFICES CORRIDOR/ COMMON AREAS TIME CLOCK AND OCCUPANCY ZONE = 50fc = 35fc = 15fc LIGHT FIXTURES ENABLED/DISABLED VIA TIMECLOCK PER C405.2.2.1 AFTER HOURS LIGHT FIXUTURES WILL BE AUTOMATIC ON VIA 2-HOUR OVERIDE SWITCH LOCATED AT ACCESSIBLE LOCATION. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE: WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. PAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 -1 W). B. FOOTCANDLE SETPOINTS: BA, LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS =15fc DAYLIGHTING ZONE 2 (SECONDARY) A. B. BA. B.B. B.C. = 50fc = 35fc DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). FOOTCANDLE SETPOINTS: LAB SPACES NON -LAB CLASSROOMS AND OFFICES CORRIDOR/ COMMON AREAS = 50fc = 35fc = 15fc LOCAL LINE VOLTAGE SWITCH ZONE fELECTRICAL/TELECOMMUNICATIONS ROOMS) • LIGHT FIXTURES IN EACH ROOM CONTROLLED VIA LOCAL LINE VOLTAGE SWITCH. NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. DASHED OUTLINE REPRESENT S AFTER HOURS OVERIDE ZONE ICORRIDORS/LOBBY) • SWITCH SHALL ENABLE ALL RELAYS CONTROLLING FIXTURES WITHIN ZONE REVIEWED FOR COMPLIANCE WITH NFPA70-NEC NOV .14 2018 City of Tukwila I DUILIJING DIVISION' architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com Sma WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.corn 0 C) De ``� U 0 ❑ 0DC rUr^ C VJ E- Q Q YO U) 4626 S. 144TH STREET z REVISION DATE Design: Drawn: Checked: Project No. AH AH RA 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING CONTROL ZONE PLAN - SECOND FLOOR BLDG B Drawing Number LIGHTING CONTROL ZONE FLOOR PLAN - SECOND FLOOR BLDG B SCME• Ire•=T-0' - NOV 02 2018 PERMIT CENTER E2.22A GENERAL NOTES 1. PROVIDE UNSWITCHED CURRENT CARRYING CONDUCTOR TO ALL EMERGENCY LIGHT FIXTURES. CONNECT TO NEAREST EXISTING LIGHTING CIRCUIT. PROVIDE CONDUIT AND CONDUCTORS AS REQUIRED. rolluda architects 4 5 0 I S2 w1E WIE C5 S2 a r LIGHTING PLAN - PARTIAL BLDG C SCALE: Ire• = 11-0• 1S2 S2 0 S2 0 2. COORDINATE EXACT MOUNTING LOCATION OF ALL LIGHT FIXTURES WITH ARCHITECTURAL PRIOR TO ROUGH -IN. 3. SEE LIGHTING CONTROL DETAILS ON SHEET E6.02. ELi 8-095 1 (Ci` PLAN NOTES 0 O CONNECT TO NEAREST EXISTING EXTERIOR LIGHTING CIRCUIT. PROVIDE CONDUIT AND CONDUCTORS AS REQUIRED. CE) r:....,..:1.1 CITY OF 1 u:¢ai;LF: NUV 02 2018 PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2018 City of Tukwila" 1 BUILDING DIVISION architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com 43-Mr STRES MST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 ww,v.treswest.cam J 0 U O LL o J o O 0 O 2 U� W <i J < YO I— U) 4626 S. 144TH STREET I — a Iwo "I a (O p CO O CO c op Q rn ° y�a,0.3 g��Oca o w Y j X.. 0 E- a E- E- LL REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING PLAN - PARTIAL BLDG C Drawing Number E2.31 0 KEYPLAN LIGHTING CONTROL ZONES: LIGHTING CONTROL ZONE FLOOR PLAN - PARTIAL BLDG C SCALE: 118• =1'-0' . ti • l i.:' rt iti• sw ELi 8-095 1 .LLLL LLLL -LLLL LLLL 'MANUAL ON' OCCUPANCY SENSOR ZONE LIGHT FIXTURES IN ROOM CONTROLLED VIA 'MANUAL ON' / 'AUTOMATIC OFF' LOW VOLTAGE LOCAL OCCUPANCY SENSOR(S). NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE: WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. DAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS DAYLIGHTING ZONE 2 (SECONDARY) A. B. B.A. B.B. B.C. = 50fc = 35fc = 15fc DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). FOOTCANDLE SETPOINTS: LAB SPACES NON -LAB CLASSROOMS AND OFFICES CORRIDOR/ COMMON AREAS TIME CLOCK AND OCCUPANCY ZONE = 50fc = 35fc = 15fc LIGHT FIXTURES ENABLED/DISABLED VIA TIMECLOCK PER C405.2.2.1 AFTER HOURS LIGHT FIXUTURES WILL BE AUTOMATIC ON VIA 2-HOUR OVERIDE SWITCH LOCATED AT ACCESSIBLE LOCATION. WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY CODE WHERE ADJACENT TO VERTICAL OR HORIZONTAL FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND TO THE QUANTITY OF INCOMING DAYLIGHT. DAYLIGHTING ZONE 1 (PRIMARY) A. DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0- 10V). B. FOOTCANDLE SETPOINTS: B.A. LAB SPACES B.B. NON -LAB CLASSROOMS AND OFFICES B.C. CORRIDOR/ COMMON AREAS DAYLIGHTING ZONE 2 (SECONDARY) A. B. B.A B.B B.0 = 50fc = 35fc = 15fc DAYLIGHT CONTROL TYPE = CLOSED LOOP, CONTINUOUS DIMMING (0 - 10V). FOOTCANDLE SETPOINTS: LAB SPACES NON -LAB CLASSROOMS AND OFFICES CORRIDOR/ COMMON AREAS = 50fc = 35fc = 15fc LOCAL LINE VOLTAGE SWITCH ZONE JELECTRICAUTELECOMMUNICATIONS ROOMS) • LIGHT FIXTURES IN EACH ROOM CONTROLLED VIA LOCAL LINE VOLTAGE SWITCH. NOT CONTROLLED VIA THE LIGHTING CONTROL PANEL. DASHED OUTLINE REPRESENTS AFTER HOURS OVERIDE ZONE !CORRIDORS/LOBBY) • SWITCH SHALL ENABLE ALL RELAYS CONTROLLING FIXTURES WITHIN ZONE REVIEWED FOR I CONFPA Apo WITH - NOV 14 2018 I City of Tukwjla _..... BUILDING DIVIEIOl,I Ftr.CEIVF;f CITY .- , ''b ),.t1 NUV 02 2018 PERM' CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com A _C1'1\ kot TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHITNG CONTROL ZONE PLAN - PARTIAL BLDG C Drawing Number E2.31A GENERAL NOTES rolluda architects 0 (E) COTS \ 124 0 FACP (E) OFFICE A110 ......... _ . . • nr : • ; ; I I I 1 i I I i• I ; !I+ 1 1 I I I I 4 tE) . i i 1 . I i ...._. __...._......._ , ..... ..... .. I P1/41108 ! I _ r 1 _ . - _t. 4- 1 4 - — 1 L WL4 - . . I WL4 1 1 , I I , I 1 --' --t- -1- ,-1 1 i E 1 i L i I 411°D-IE Cl ® *WE I VESTIBULE A100A ® *ME ® 41E 1. PROVIDE UNSWITCHED CURRENT CARRYING CONDUCTOR TO ALL EMERGENCY LIGHT FIXTURES. 2. COORDINATE EXACT MOUNTING LOCATION OF ALL LIGHT FIXTURES WITH ARCHITECTURAL PRIOR TO ROUGH -IN. DiE (DO [HE I LIGHTING PLAN - BLDG A ENTRY Eo6 SCALE: VC 21'0 -)2 EL18-0P1 PLAN NOTES 0 PROVIDE NEW FIRE ALARM PANEL. RECONNECT ALL EXISTING DEVICES TO REMAIN BACK TO NEW FIRE ALARM PANEL. CONNECT TO EXISTING CORRIDOR LIGHT CIRCUIT. ROUTE NEW CONDUIT AND CONDUCTORS TO NEAREST EXISTING LIGHT FIXTURE. EXTENDED EXISTING CONDUIT AND CONDUCTORS TO NEW LIGHT FIXTURES. PROVIDE RESCUE ASSISTANCE BASE STATION. CITY OF IL. i:cWIL/i. Nth 02 2018 PERP,IIT CENTER HEVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 4 DM City of Tukwila — BUILDING DIVISION KEYPLAN architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com 41-Aftr— it TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 0 0 0 w 0 I— co co w 0 a 0 0 w < _J < 0 D U) 4626 S. 144TH STRE REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title LIGHTING PLAN - BLDG A ENTRY Drawing Number E2.51 GENERAL NOTES PLAN NOTES O NOT USED rolluda architects e (E) PNL 'LA' (E) 200A DISCONNECT PNL '1Z2'- POWER FLOOR PLAN - BLDG A SCALE. 118"=1'-0' A4.1 d 1. WALL MOUNTED DEVICES SHALL NOTE BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION IN BOXES 2. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 3. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 4. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. EL18-0951 AG REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2018 City of Tukwila — BUILDING DIVISION t.11 Y _if• vii .tif.+ NUV 02 2018 PE t.7IT CEriITER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mai I@rolludaarchitects.com TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J O UO cc U mu) CD J J o O 0 O 2 U� W J Q YO I- U) 4626 S. 144TH STREET I— U 0 - F o w co JnoCOoco — _ (cm-8 rnN N (DIW Q O f `If I— LL REVISION DATE Design: AH Drawn: AH Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title POWER PLAN - BLDG A Drawing Number E3.11 KEYPLAN A It1P21-11 _ SCIENCE B108 \:1P21-9 lent 1P21-12 Aohr `440- 1P21-11�} 1111A SCiE NC PREP 1P21-14� 1P21-4 A REFRIGERATOR C I f 1P21-2 ' A 1P21-4 A C 'i f 1 P21-2 A A 1P21-1 °—. A �I,gp 1P21-3 I C '.t 1P21-1 A 1P21-3 A POWER FLOOR PLAN - FIRST FLOOR BLDG B SCALE Srs 1 P21-10 A 1P21-4 CA 1 P21-9 1P21-11 I Ce�pp 1P21-13 DIGITAL DISPLAY AND AUDIO ENHANCEMENT,„,1 P21-115p p1111PP21-26 +84 IQv 1P21-15 I' 1P21-9 C A A 1 P21-10 1P21-13I`. cI 1P21-13,151,11 1P21-11 1P21-9,11 ,. 11 1P21-10 1P21-12 1P21-10,12I44 1 P21-10 1 P21-10 ii9 PP21-4 CPA 1P21-2 DIGITAL DISPLAYAND--- '1 -AUDIOENHANCEMENT Th.,44,1P21-8 !�{ +e4• @ ;il P21-8 { IIP21.6,8 c I 1P21-6 I'` 1P21-4 1P21-2,4 I f 1P21-4 1P21-2 A- 1P21-26 LLU - UAL_JIT1.`� 1P21-1,3. A1P2� �-1 1`tPY21-3. 1P21-3 SCIENCE CAB B104 TS SCIENCE LAB.. _B102- YI 1P21- ,7]_ 1P21-26 C 1P21-5 SHARED/ SPACE' 0.100 01 DIGITAL DISPLAY AND AUDIO ENHANCEMENT 1P21-7 +84• 1P21-7 Al I { CREATIVE LEARNING LAB El U1 C ,;iP2A-16,18 { 11P21-28 1P21-28 1P2A-2.19 C 1 P2A-17,19 MUSIC* ROOM B109 DIGITAL DISPLAY AND AUDIO ENHANCEMENT 1P2A-17,19 C +�,F{, 1P21-23 Cd 1 P2A-19,21 I 1P2A-,23 1P2A-22123 1P21-212 1P21-17,19 C 1P2A- ,27 ()FI IC i. PRACTICE 1P21-27 1P2A-25,27 B11; 1P21-27 1P2A-25,27 r1 P2A- ,27 1 GIRLS RESTROOM 13107 1P21 28..-. 1 11,, MECHANICAL/ 1P21-16,18 ELEC/CUST I, C"A 1P21-16 L _ J 1P21-20,22, W w r,,11.31:caMMP OPMW W C ((j) 1P2A-20,24 +84^H 1P21-24 DIGITAL DISPLAY AND I AUDIO ENHANCEMENT 1P21-28 v. ,�-- 1P2A-1M,16 � C 1P21-26 VEST 310GA 1 P2A-20,22 1 P2A-2Q,22 C 111 ;BE) -1-) 81.1E cam ADJ GENERAL NOTES 1. WHERE TWO CIRCUITS ARE SHOWN AT A CONTROLLED RECEPTACLE, UNDERLINED CIRCUIT INDICATES THE CONTROLLED CIRCUIT. REFER TO DETAIL ON SHEET EX01 FOR CONTROLLED RECEPTACLE WIRING. 2. WALL MOUNTED DEVICES SHALL NOTE BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK. PROVIDE SOUND INSULATION IN BOXES. 3. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 4. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 5. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. MECHANICAL/ ELEC/CUST 6105 I PLAN NOTES O PROVIDE POWER TO FIRE ALARM ANNUCIATOR PANEL. 81.28 XFMR T-122' ATS T XFMR TAN' DIST.'DP-B' 1\ 200A BLSSED GUTTER 200AS/200AF rm ENLARGED FLOOR PLAN - BLDG B ELECTRICAL ROOM B105 2 1\ i SCALE: 114' =11-0' B12B B1 ELEV CL— B10 --PNL' L< 1EL2 PNL'1EL4' ELEVATOR CONTROL UNIT ENLARGED FLOOR PLAN - BLDG B ELEVATOR ROOM B105A SCALE: 114' =11-0' ELi 8-095 1 NOV 02 20113 PE MT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2018 City of Tukwila BUILDING DIVISION rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 w.ww.tresvest.corn 4626 S. 144TH STREET a REVISION DATE Design: Drawn: Checked: Project No. AN AN SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title POWER PLAN - FIRST FLOOR BLDG B Drawing Number E3.21 KEYPLAN GENERAL NOTES 1. WHERE TWO CIRCUITS ARE SHOWN AT A CONTROLLED RECEPTACLE, UNDERLINED CIRCUIT INDICATES THE CONTROLLED CIRCUIT. REFER TO DETAIL ON SHEET EX.01 FOR CONTROLLED RECEPTACLE WIRING. rolluda architects i SECURITY HEADENDT INTERCOM HEADEND ACCESS CONTROL HEADEND-_. , DATA CABINET i0, L _ ELEC B203B PNL'2P2' LTG'INV1' e-LCP1 1-a--PNL'1L4' \-PNL'1M2' PNL '1M4' XFMR T-1M2' ENLARGED FLOOR PLAN - BLDG B ELEC ROOM B203B SCALE: 1/4'=1'4' C-04 1 11 2P2-19,21 C* 2P2-13,15 C 2P2-19,21 2P2-1$.21 MATH CLASSROOM B208 DIGITAL DISPLAY AND AUDIO ENHANCEMENT 2P2-23 „+34' C 2P2-19,23 C 2P2.19 C 2P2-20 1 2P2.12,21 2P2-19,21 Cu 2P2-13,15 MATH CLASSROOM B206 DIGITAL DISPLAY AND AUDIO ENHANCEMENT 2P2-f,15 Co 2P21,3 c aP2.1,3 2P2-19,21 Co 2P2-13 C ti 2P2-19,2i1,23 ® 2P2-20 .I 2P2-13,15� 2P2-13�115,17 2P2-11-7 tmµ.+84- 2P2-13,15 019 C2P2-1.1J7^ C" 2P2-7,9 C 2P2-7,9 MATH CLASSROOM B20.4 DIGITAL DISPLAY AND AUDIO ENHANCEMENT 2P2-1111 2P2-7,116C- 2P2-1,54C 2-1,3 1P+84• I5 2P2 DIGITAL DISPLAY AND AUDIO ENHANCEMENT MATH CLASSROOM B202 2P2-1.3 rem POWER FLOOR PLAN - SECOND FLOOR BLDG B SCALE: 1/B'=t'4' 2P2-13,15 C� A 2P2-7 7 C 2P2-7,9 C� 2P2-7,9 2P2-7,9 Co 2P2.7,i11 C� 2P2-20 2P2i20 A 2P2-1 >� 2P2-1,3 C C ` 2P2-1,3,5 CI I 2P2-1,3 2P2-20 �I 2P2-1,3 Co_ 21Q6,10 2 28,10 2P2-8,10 Occ I• 2P2-223@ ART ROOM B211 C 2P2.12 rDIGITAL DISPLAY AND +84• AUDIO ENHANCEMENT 2P2.8,12 I 2P2-22 2P2-8.10 Pre If 2P2-8,1O' 2 2P2-18 STORAGE B213 2P2-16 A iI- , 2P2-8 A 2P2-18 KILN O I B215 ;® I C4 2P2.8,10 C 2P2-8,10 BOYS RESTROOM II ST 321 2P2-14 1 © I� 2P2-14 1® jI 3P2-22 2P2-14,16 c ,,1 2P2-2,4 C I2P2-2,4 VEST' .II L2DOA C 2P2-22 2P2-2,4 2P2-2,4 y 2P2-14 PREP B203 2P2-16 2P2-16 Adt Alt 2P2-2.4.6 A^C 2P2-2 MATH CLASSROOM B2G1 2P2-14 2P2-14{ W! C 2P2-2,4 2P2-S +sa Qb C 2P2-2,6 .) EL18-0951 2P2-2,4 4 2P2-2,4 C I I I 2. WALL MOUNTED DEVICES SHALL NOTE BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION IN BOXES. 3. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 4. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 5. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. PLAN NOTES O PROVIDE CONNECTOIN TO OWNER PROVIDE KILN. COORDINATE CONNECTION REQUIREMENTS PRIOR TO ROUGH IN. NUV 02 2018 PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2010 City of Tukwila BUILDING DIVISION architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com =vim sTRES WEST DOWERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA98409-7315 Phone:253.472.3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title POWER PLAN - SECOND FLOOR BLDG B Drawing Number P PLAN NOTES OEXTEND EXISTING CONDUIT AND CONDUCTORS TO NEW CU UNIT AS REQUIRED. rolluda architects CU-A06 CU-A05 CU-A04 IDOAS-01 CU-A09 z CU-A06 J�O CU-A07 MECHANICAL POWER PLAN - PARTIAL ROOF BLDG A SCALE: P' =10'-0' GENERAL NOTES 1. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 2. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 3. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. CU-A03 EL18-0951 CU-A02 ;O CU-A01 1D® REVIEWED FOR COMPLIANCE WITH NFPA70- nlFr Nov 1,4 2018 City of Tukwila BUILDING DIVISInv CITY OF NOV 02 2018 PERMIT CENTER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 4626 S. 144TH STREET U a co wco cc (o 0 ((0 8��co mrc—op ai~>°'rn 5-giain J� o I- (. fr. W Q F'�FFLi- REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title MECH POWER PLAN - BLDG A PARTIAL ROOF Drawing Number E4.12 PLAN NOTES O NOT USED BD1 SCIENCE PREP 81 SCIENCE LAB B10S ECU-8107 FCU-B105 SCIENCE LAB E31 0-i SCIENCE LAB B102 BC-2 FCU-B106 FCU-B108 Lni rt FCU-B104 i MECHANICAL POWER FLOOR PLAN - FIRST FLOOR BLDG B tv stag: ihr =1'W - 1 SHARED SPACE B100 4 (3-14 I 1 A2 MUSIC ROOM B109 FCU-B103 PRACTICE B 11 FCU-B102f)F-IPE ill.. GIRLS REStRnn__ i; ,;i J MECHANICAL! ELEC/COST B105 CREATIVE LEARNING LAB 1101 GENERAL NOTES 1. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 2. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 3. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. I LA 11 OFFICE E 00 AC-02 (E) CUST.STOR A140 ELi 8-095 1 BE BD AC; MN 02 2018 PERMIT CENTER REVIEWED FOP? COMPLIANCE WITH NFPA 70 - NEC NOV 4 2018 City of Tukwila -- BUILDING DIVIS'nN rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com =vim 4u Tres WED* ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409.731 S Phone: 253.472.3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: AH Drawn: AH Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title MECH POWER PLAN - FIRST FLOOR BLDG B Drawing Number E4.21 KEYPLAN PLAN NOTES O NOT USED rolluda architects '13)4 II MAT CLASS't-J B2U MATH CLASSROOM B20h FCU-8207 FCU-B206 FCU-B205 MATH FCU-8204 MATH CLASSROOM 6202 �Al MECHANICAL POWER FLOOR PLAN - SECOND FLOOR BLDG B SCALE: 1B' =1'-01 i� PF-01 PF-02 vs) i' 1 1; ART ROOM B211 FCU-B203 STORAGE B213. It 1 U r { KILN B215 I BOYS RESTROOM B209 PREP 03 FCu-B202� G1 B ! FCU-B201 MATH CLASSROOM B201 1 BE BD BCi GENERAL NOTES 1. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 2. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 3. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. ELi 8-095 1 CITY ice; `s u: !LA. NUV 02 2018 PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2018 City of Tukwila BUILDING DIVISION KEYPLAN architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com STRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone:253.472.3300 www.treswest.cam J Ir Ico coV J o J o O0 O2 UCC w as YO I- CO 4626 S. 144TH STREET REVISION DATE Design: AH Drawn: Ali Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title MECH POWER PLAN - SECOND FLOOR BLDG B Drawing Number E4.22 PLAN NOTES NOT USED 1 s 0 I BC1 Ii k \I MECHANICAL POWER FLOOR PLAN - ROOF BLDG B SCALE: lir =1'-0' • I Al) S WP ODU-2A ODU-2B I; wP DOAS-03 ODU-1A WP C ODU-1B DOHS-02 i i I� EL18-0951 A r3 i GENERAL NOTES 1. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUIT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 2. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 3. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. • BE AC Cr' 117 Y'..r8`•ui...:�!y: NOV 02 2018 PERMIT hIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 2018 City of Tukwila BUILDING _DIVIS!Ci�l U t rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TIRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACONIA, WA 98409-7315 Phone: 253.472.3300 www.tresvest.com 4626 S. 144TH STREET CO 1— CI W c0 J rcro0 co O co 2 op O 1— _ o z ut• ��}NXX • ' c D W o I— ct I— U. REVISION DATE Design: AH Drawn: AH Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title MECH POWER PLAN - ROOF BLDG B Drawing Number E4.23 KEYPLAN PLAN NOTES 0 PROVIDE POWER TO MOTORIZED HOOPS. rolluda architects f DOAS-04 F- MECHANICAL POWER FLOOR PLAN - BLDG C 1 GENERAL NOTES 1. DEVICE INSTALLED IN FIRE RATED WALL SHALL REQUIRE ENCLOSURE AROUND DEVICE TO COMPLE RATING OF WALL COORDINATE WITH ALL TRADES, SEAL CONDUCT PENETRATIONS WITH APPROVED FIRE STOPPING MATERIALS. SEE ARCHITECTURAL CODE SHEETS FOR ADDITIONAL INFORMATION. 2. FINAL LOCATION OF EQUIPMENT DISCONNECTS/CONTROLLERS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO ROUGH -IN. NEC REQUIRED CLEARANCES SHALL BE MAINTAINED. A UNISTRUT ASSEMBLY SHALL BE CONSTRUCTED FOR ALL DISCONNECT/CONTROLLERS WHICH CANNOT BE LOCATED ON BUILDING STRUCTURE. PROVIDE ALL MATERIALS AS REQUIRED. 3. SEE ELECTRICAL MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. EF-1 ELi 8-095 1 i?c"r. -•1!s i uiQ.`0 L1; NOV 02 2018 PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 14 2018 City of Tukwila BUILDING DIVISION architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com S. 144TH STREET a REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title MECH POWER PLAN - PARTIAL BLDG C Drawing Number E4.31 KEYPLAN 0 I u GENERAL NOTES PLAN NOTES Oj NOT USED rolluda architects rSYSTEMS FLOOR PLAN - BLDG A SCALE: 118' : T-0' A4 @ 4 1. ROUTE NEW FIRE ALARM DEVICES BACK TO NEW FIRE ALARM CONTROL PANEL OR NEAREST FIRE ALARM DEVICE. FIRE ALARM CONTROL PANEL LOCATED IN BLDG A ROOM A10B. SEE SHEET E2.51 FOR EXACT LOCATION. ELi 8-095 1 A4.9) REVIEWED FOR COMPLIANCE WITH NFPA.70 - NFr` NOV 1 4 2018 City of Tukwile BUILDING DIVIR" f q r NOV 02 2018 PERj T CENTER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACCMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.corn J O UO 1, 0J J0 00 Og cow << YO r VJ 4626 S. 144TH STREET CC) co w woe o o iessjr (6 _ a' Y� co 7 W Q F-I—LL REVISION DATE Design: AH Drawn: AR Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title SYSTEMS PLAN - BLDG A Drawing Number E5.11 GENERAL NOTES PLAN NOTES Oj NOTE 1 i I SCIENCE 0 Like BIIO8 SCIENCE O PREP SYSTEMS FLOOR PLAN - FIRST FLOOR BLDG B SCALE: UB':tor B106 SCIENCE LAB SD 81041 E55 SCIENCE LAB B102 2 9 ll I II l` 1 1 1 I 1 1 i it 1 SHARED I SPACE B 1,00 1 PRICE B111 2 4 GIRLS RESTROOM 13107•. MUSIC ROOM B109 ® OFFICE B113 MECHANICALJ ® ELECICUST CB105 DI 2 CREATIVE LEARNING 2 LAB B101 ELEV CI.. B 1 d5A 1. ROUTE NEW FIRE ALARM DEVICES BACK TO NEW FIRE ALARM CONTROL PANEL OR NEAREST FIRE ALARM DEVICE. FIRE ALARM CONTROL PANEL LOCATED IN BLDG A ROOM A108. SEE SHEET E2.51 FOR EXACT LOCATION. CBE i EL18-0951 BA CiTt •;1 r:, NUV 02 2018 PERT.".i i C74, TER REVIEWED FOR COMPLIANCE WITH NFPA70-NF " NOV 14 2018 City of Tukwila BUILDING DIME!` rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com 41-1A/1— t` TRES wEST lIIGRImtS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOM A, WA 98409-7315 Phone: 2553.472. 3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: AH Drawn: AH Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title SYSTEMS PLAN - FIRST FLOOR BLDG B Drawing Number E5.21 KEYPLAN GENERAL NOTES PLAN NOTES 2 a s I BD1 ESS MATH CLASSROOM 10 i B208 9 MATH CLASSROOM sD B20i _ 4 MATH sD CLASSROO r B204 MATH CLASSROOM -11s- B2U2sD SYSTEMS FLOOR PLAN - SECOND FLOOR BLDG B SCALE: 1/8'=11•0' VEST ..I. S R ESS S ART ROOM ill 11233 STORAGE B213 yy�� BOYS 'hR RESTROOM I� /4091 B215 CI MATH 2 CLASSROOM B201 ESS PREP) B203 1. ROUTE NEW FIRE ALARM DEVICES BACK TO NEW FIRE ALARM CONTROL PANEL OR NEAREST FIRE ALARM DEVICE. FIRE ALARM CONTROL PANEL LOCATED IN BLDG A ROOM A108. SEE SHEET E2.51 FOR EXACT LOCATION. y13) EL18-0951 0-3? CAThDI 1 PROVIDE RESCUE ASSISTANCE CALL STATION. PROVIDE WIRING BACK TO RESCUE ASSISTANCE BASE STATION LOCATED IN BUILDING A RECEPTION A108. SEE SHEET E2.51 FOR EXACT LOCAITON. REVIEWED FOR COMPLIANCE WITH NFPA710-NEC NOV 14 2018 City of Tukwila BUILDING DIVISION ern T Ji" Vi-.':ii f NOV 02 2018 PER'.`ir CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com v v- i1lES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone:253.472.3303 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: Drawn: Checked: Project No. AH AH SKF 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title SYSTEMS PLAN - SECOND FLOOR BLDG B Drawing Number E5.22 KEYPLAN PLAN NOTES 0 NOT USED rolluda architects I U w i I n r SYSTEMS FLOOR PLAN - BLDG C SCAl F: U8'•1'-0' 7 GENERAL NOTES 1. ROUTE NEW FIRE ALARM DEVICES BACK TO NEW FIRE ALARM CONTROL PANEL OR NEAREST FIRE ALARM DEVICE. FIRE ALARM CONTROL PANEL LOCATED IN BLDG A ROOM A108. SEE SHEET E2.51 FOR EXACT LOCATION. ELi 8-095 1 CD (CBS Ci fl ,314 ui.;),LLA NOV 02 201B PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA70-NEC NOV 14 2018 City of Tukwila BUILDING DIVISI!'' architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com t V ,ltES WEST torts TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 vn w.treswest.can 4626 S. 144TH STREET K U I- U3 ow LU CO grg�� di 3 N 0 D W F-V I—FLL REVISION DATE Design: Drawn: Checked: Project No. AH AH SJR 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title SYSTEMS PLAN — PARTIAL BLDG C Drawing Number E5.31 KEYPLAN rolluda architects SMOKE DUCT DETECTOR TO FACP / HVAC CONTROLLER U 7 0 HVAC EQUIPMENT SMOKE DUCT DETECTOR J TO FACP DUCTWORK AIR RETURN AIR SUPPLY HVAC EQUIPMENT SHUT -DOWN WIRING DIAGRAM N.T.S. NOTES: 1. FIRE ALARM DUCT DETECTORS ARE REQUIRE FOR ALL HVAC UNIT 2000CFM OR ABOVE PER CODE AND AHJ. FIRE ALARM DUCT DETECTORS ARE TYPICALLY SUPERVISORY ALARM MODE, BUT SOME LOCAL AHJ WANT ALARM MODE. COORDINATE WHAT MODE THE AHJ WANTS FOR THIS SITE PRIOR TO FINAL PROGRAMMING AND INSPECTION. 2. IF POSSIBLE IN LARGE HVAC UNITS MOUNT DUCT DETECTOR INSIDE THE HVAC UNIT. LABEL EXTERIOR DOOR WITH NAMEPLATE PER SPEC. 3. LOCATION OF THE FIRE ALARM DUCT DETECTOR SHALL BE MOUNTED MINIMUM OF 3-FEET IN OR ON AIR DUCTS SHALL BE DOWNSTREAM FROM ANY DUCT OPENINGS, DEFLECTION PLATS, SHARP BENDS OR BRANCH CONNECTIONS. 4. THIS DETAIL SHOWS THE SHUT DOWN OF HVAC UNIT UPON FIRE ALARM DUCT DETECTOR ALARM OR SUPERVISORY MODE AS REQUIRED TO BE CONTROLLED BY CODE. 5. PROVIDE LOCAL OVERRIDE OF THE HVAC UNIT, CONDUIT, WIRING, AND CONNECTIONS AS REQUIREMENT PER CODE. 6. FIRE ALARM CONTRACTOR TO PROVIDE DUCT DETECTOR TO MECHANICAL CONTRACTOR TO BE INSTALL AND ELECTRICAL CONTRACTOR WIRE ALL CONNECTIONS TO THE HVAC UNITS AND DUCT DETECTORS. 7. MOUNT DUCT DETECTORS PER CODE AND IN ACCESSIBLE SPACE. PROVIDE REMOTE TEST/LED ANNUNCIATOR FOR ANY DUCT DETECTOR THAT IS ABOVE DROP CEILING AND HAS HARD ACCESS. 8. PROVIDE DUCT DETECTOR FOR ALL FIRE/SMOKE DAMPER WITHIN 3-FEET OF DAMPER AS REQUIRED BY AHJ AND CODES. 9. PROVIDE NAMEPLATE REFER TO SPEC ON ACCESS POINT AND NEXT TO DROP CEILING TILE. 10. PROVIDE A WRITTEN DETAIL DESCRIPTION OF EACH DUCT DETECTOR LOCATION TO DIRECT A PERSON TO THAT LOCATION IN THE CLOSEOUT DOCUMENTS. ROOF ATTIC UPPER LEVEL PROVIDE CONNECTION TO ELEV. RECALL TO FACP MAIN RECALL RELAY ALTER RECALL RELAY HAT RECALL RELAY ELEVATOR SHUNT TRIP POWER LOSS POINT LOWER LEVEL SMOKE HAT RECALL SHUNT TRIP HEAT - WITHIN 18" OF SPKLR HEAD SHUNT TRIP HEAT DETECTOR MONITORING Et et EMERG. ELEV. RETURN UNIT ELEV CONTROL PANEL ELEVATOR MOTOR ELEVATOR MOTOR ALTER RECALL 4LEVATOR CAB 3PROVIDE CONNECTION TO 5°f SHUNT TRIP SWITCH m O ELEVATOR ROOM ELEVATOR LOBBY MAIN RECALL ELEVATOR LOBBY ALTER RECALL ELEVATOR SHAFT iELEVATOR RECALL AND SHUNT TRIP DIAGRAM K3) N.T.S. PROVIDE FUSIBLE SHUNT TRIP SWITCH WITH AUXILIARY RELAYS. REFER TO ONE -LINE DIAGRAM, SHEET E8.01, FOR SIZE. PROVIDE BUSSMANN #PS (POWER MODULE SWITCH) FOR ELECTRICAL SERVICE TO ELEVATOR, SHUNT -TRIP CONTROL, & POWER LOSS RELAY. (LOCATED IN ELEVATOR MACHINE ROOM) ELEVATOR LOBBY NOTES: 1. FA TO PROVIDE ADDRESSABLE SMOKE DETECTORS IN ELEVATOR MACHINE ROOM, IN FRONT OF ELEVATOR LOBBY DOOR OPENING, TOP OF SHAFT FOR ELECTRICAL RECALL PROGRAM FUNCTIONS. FA TO PROVIDE THREE (3) ADDRESSABLE RELAY MODULES FOR ELECTRICAL RECALL MAIN, ALTERNATE, HAT PROGRAM FUNCTIONS PER ELEVATOR CODE. CONTRACTOR TO PROVIDE COMPLETE WIRING AND CONNECTIONS TO ELEVATOR CONTROLLER FOR COMPLETE OPERATION OF RECALL SYSTEM. 2. FA TO PROVIDE DUAL 120V RATED FIXED HEAT 135F DETECTORS FOR ELEVATOR SHUNT TRIP CONTROL. FA TO PROVIDE ADDRESSABLE MINI POINT MODULES TO MONITOR HEAT DETECTORS PER ELEVATOR CODE. FA TO PROVIDE ADDRESSABLE POINT MODULE TO MONITOR SHUNT TRIP POWER LOSS PER ELEVATOR CODE. CONTRACTOR TO PROVIDE COMPLETE CONNECTIONS TO SHUNT TRIP COIL IN SWITCH, RELAY, AND POWER INDICATION LED LIGHT. PROVIDE NAMEPLATES ADJACENT TO DETECTORS "DO NOT TEST". 3. CONTRACTOR TO COORDINATE CONNECTION REQUIREMENTS WITH ELEVATOR SUPPLIER/CONTRACTOR PRIOR TO WORK. 4. CONTRACTOR TO PROVIDE COMPLETE POWER AND CONTROL CONNECTIONS TO ELEVATOR SYSTEM FOR COMPLETE OPERATION PER THE MANUFACTURER'S INSTRUCTIONS, WIRING DIAGRAMS, AND ALL CODES. RECONNECT EXISTING TWO (2) TELEPHONE LINES (E)POST INDICATOR VALVE & VAULT TAMPER SWITCHES _ (E)BACKFLOW TAMPER SWITCHES _ Th (E)WET FIRE SPRINKLER RISER TAMPER SWITCHES M (E)WET FIRE SPRINKLER RISER FLOW SWITCHES (E)WET FIRE SPRINKLER RISER TAMPER SWITCHES -411--H4 (E)WET FIRE SPRINKLER RISER FLOW SWITCHES ._M4 (E)DRY FIRE SPRINKLER RISER TAMPER SWITCH M (E)DRY FIRE SPRINKLER RISER HI -LOW AIR SWITCH (E)DRY FIRE SPRINKLER RISER FLOW SWITCHES 4 (E)DRY FIRE SPRINKLER RISER TAMPER SWITCH (E)DRY FIRE SPRINKLER RISER HI -LOW AIR SWITCH (E)DRY FIRE SPRINKLER RISER FLOW SWITCHES (E)EMCS CONTROL EXISTING PRINTER DED. CKT 0 HD CONTROL RELAY - M CONTROL RELAY RETURN D (E)DOOR HOLDER CIRCUIT PROVIDE AND CONNECT 4TO 120VAC POWER O,A J . (E)FIRE/SMOKE DAMPER CIRCUIT (E)FIRE ALARM AUDIONISUAL ALARM CIRCUIT TYPICAL OF�EXISTING FIRE ALARM SLC LOOP DEVICES AND DETECTORS (E) REMOTE INDICATING LIGHT TO SIGNAL SMOKE DUCT DETECTOR ACTIVATION. MOUNT D IN CEILING BELOW UNIT. (E) CONNECTION TO DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS OF 2000 CFM AND OVER SEE MECH DRAWING EQUIP. SCHEDULES. HVAC SHUNT TRIP AC POWER O (E)HVAC DDC CONTROL PANEL FOR HVAC SHUT DOWN ELEVATOR DUAL HEAT DETECTOR MONITORING MODULE ©F ELEVATOR SHUNT TRIP POWER LOSS MONITORING MODULE ELEVATOR ELEVATOR ELEVATOR MAIN ALTER HAT RECALL RECALL RECALL CONTROL CONTROL CONTROL RELAY RELAY RELAY A 120VAC NEW FIRE ALARM SLC LOOP DEVICES AND DETECTORS FM (N)FIRE ALARM REMOTE LCD ANNUNCIATOR DEDICATED 120V CIRCUITS, SEPARATE HOME RUN AND INSULATED GROUND. NEW EST 101000 FA PANEL EXISTING FA-NAC PANEL EXISTING FA-NAC PANEL BATTERY CABINET FIRE ALARM SYSTEM ONE -LINE DIAGRAM N.T.S. FIRE ALARM NOTES: IFIRE ALARM SLC LOOP DEVICES AND DETECTORS o EXISTING FA-NAC PANEL EXISTING FA-NAC PANEL u (E)AUDIONISUAL ALARM CIRCUIT TYPICAL (E)AUDIONISUAL ALARM CIRCUIT TYPICAL (E)AUDIONISUAL ALARM CIRCUIT TYPICAL (E)AUDIONISUAL ALARM CIRCUIT TYPICAL NEW FA-NAC PANEL [MAP (E)FIRE ALARM REMOTE GRAPHIC LED ANNUNCIATOR MAP I FAA] (E)FIRE ALARM REMOTE LCD ANNUNCIATOR GROUNDING NEW AUDIOVISUAL ALARM CIRCUIT TYPICAL 1. PROVIDE ALL J-BOXES, CONDUIT, WIRING & CONNECTIONS TO ALL DEVICES FOR COMPLETE FIRE ALARM SYSTEM. 2. ALL DEVICES WILL BE MOUNTED IN AN ACCESSIBLE SPACE AND AT THE ELEVATION PER NFPA 72. ADA, AND AHJ CODES. 3. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACE. 4. PROVIDE COMPLETE GROUNDING TO EQUIPMENT PER MANUFACTURERS RECOMMENDATION. 5. SEE FIRE ALARM SPECIFICATION FOR COMPLETE DETAILS. 6. PROVIDE NEW FIRE ALARM PANEL ADDRESSABLE. 7. PROVIDE SHUT DOWN CONNECTIONS FOR ALL 2000CFM HVAC UNITS WITH DUCT DETECTORS AS SHOWN. 8. SET ALL VISUAL DEVICES TO PROVIDE THE RIGHT COVERAGE OF CANDELA FOR THE SPACE PER NFPA 72 AND AHJ CODES. 9, SET ALL AUDIO DEVICES TO TEMPORAL AND TO BE 15dB ABOVE AMBIENT SOUND LEVEL OF THE ROOM PER NFPA 72 CODES TABLE. 10.ALL AUDIO AND VISUAL DEVICE WILL BE SYNC PER NFPA 72 CODES. 11.PROVIDE COMPLETE REPROGRAMMING OF SYSTEM TO UPDATE ALL ZONES, ADDRESSES, AND DIALER MONITORING BY POINTS. 12.PROVIDE COMPLETE SHOP PLANS FOR INSTALLATION AND AS -BUILT SET OF THESE PLANS NEXT TO FIRE ALARM PANEL ON COMPLETION. 13.PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. 14.PROVIDE FIRE ALARM NETWORK MODULES BETWEEN BUILDINGS TO USE ONE DIALER FOR MONITORING. 15.THE EXISTING EST QUICK START FIRE ALARM PANEL IS OBSOLETE AND IS NOT SUPPORTED BY MANUFACTURER. 16.REPLACE EXISTING FIRE/SECURITY PANEL/DIALER & EST QUICK START WITH NEW EST 10-1000 FIRE ALARM PANEL. ALL EXISTING FIRE ALARM DEVICES TO REMAIN. PROVIDE PROGRAMMING AND A COMPLETE FIRE ALARM SYSTEM TEST TO GENERATE AN EVENT LOG REPORT WITH CENTRAL STATION MONITORING OF ALL FIRE ALARM ADDRESSABLE POINTS ALARM, SUPERVISORY, AND TROUBLES. 17.FIRE ALARM CONTRACTOR TO SUBMIT DRAWINGS FOR FIRE ALARM PERMIT BY TUKWILA BUILDING DEPARTMENT. 18.PROVIDE NEW AS -BUILT AUTOCAD DRAWINGS BY THE FIELD VERIFICATION OF ALL EXISTING FIRE ALARM SYSTEM. DOWNLOAD EXISTING PROGRAM DATA OF THE EXISTING FIRE ALARM SYSTEM. MATCH THE EXISTING DATA WITH NEW AS -BUILT DRAWING. PLOT OUT 11 BY 17 DRAWINGS TO BE PROVIDED FOR THE FINAL TEST OF THE EXISTING FIRE ALARM SYSTEM. 19.PROVIDE THE AHJ AT FINAL ACCEPTANCE THE FOLLOWING DOCUMENTS: a. AS -BUILT DRAWINGS SHALL BE FULL CONSTRUCTION SET WITH REDLINE MARKUPS THAT CONTAIN THE FOLLOWING (ALL ZONING, DEVICE POINT NUMBERS, NEW DEVICE CONDUIT OR WIRING PATHWAYS, AND EXACT LOCATION OF DEVICES AND PANELS.) b. EXISTING AS -BUILT DRAWINGS SHALL HAVE ALL FIRE ALARM PANELS AND DEVICES. c. HAFT SIZE GRAPHIC MAP OF EACH FLOOR WITH ZONES AND ADDRESSABLE POINT DEVICES. ( NO WIRE ) d. CENTRAL STATION MONITORING PRE -TEST REPORT OF ALL ADDRESSABLE POINTS. e. FIRE ALARM PANEL ALARM, SUPERVISORY, AND TROUBLE EVENT LOG REPORT OF ALL DEVICES. f. ADDRESSABLE POINTS LIST. g. WRITTEN DETAIL DESCRIPTION OF EACH DUCT DETECTOR LOCATION TO DIRECT A PERSON TO THAT LOCATION IN THE CLOSEOUT DOCUMENTS. PROVIDE PHENOLIC LABEL INDICATING FOR ALL DUCT DETECTORS. h. COMPLETED NFPA 72 RECORD OF COMPLETION AND INSPECTION CURRENT FORMS TO OWNER AND AHJ. i. PROVIDE THE DIGITAL COPY OF ALL ABOVE ON ONE FOLLOWING (CD-ROM, DVD, OR FINGER DRIVE). j. PROVIDE ALL THE ABOVE DOCUMENTS IN O&M MANUALS BINDER. k. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. REVIEWED Rfr COMPLIANCE WITH NFPA 70 - NFC NOV 1 4 2018 City of Tukwila I BUILDING DIVISir •'• ELi 8-095 1 r-t..-.1,. NOV 02 2018 1'c11f SIT CaNTER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com =ur leset TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACO/AA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J O 00 L.1_ VJ VJ ❑J O 0 O g VJ 1 co <QO 0o 1� VJ Q _U co i7 w rn J WCOO CO 0 O ^ 0 O 09 8 1 < V = Q rn " . N � � rn rn e'- co co 3 N Y z Y o Y N v w vHo Hf HILL REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL DETAILS Drawing Number E6.01 COPYRIGHT C 0018 ROLLGGA A rolluda architects To Closest Available Dataline Terminal Lighting Load 1 (Relay 1) Dim 1 Lighting Load 2 (Relay 2) Dim 2 Lighting Load 3 (Relay 3) Dim 3 \ Receptacle (Relay 4) PURPLE I RED YELLOW Receptacle 120Vac Distribution Cabinet (by Others) NEUTRAL /1 o 0 BLUE Lighting 120/277/347Vac Distribution Cabinet (by Others) NEUTRAL BLUE n 0 o 0 0 WHITE BLACK D-10V Dimming (18/2 per channel) Room Controll r (WRC-3160) JO JO JO 10 DIM I DIM 2 DIM 3 DIM 4 DATALINE DO NOT USE I PURPLE F LIGHTING LOAD I LIGHTING LOAD 2 LIGHTING LOAD 3 RECEPTACLE LOAD 4 RECEPTACLE HOT FOR LOAD 4 ( WHITE F NEUTRAL LIGHTING HOT FOR LOAD 1.2 & 3 RED YELLOW BLUE BLUE BLACK 0— Dialog Network Dataline (18/2) Typical Devices Only. PLEASE SEE INTERFACE LIST FOR EXACT DEVICE QUANTITIES. Daylight Sensor WPS-3711 r Occupancy Sensor Ceiling Mount Occupancy Sensor Corner Mount From Closest Available Dateline Terminal Seme Multi -button Switch Station C?) LIGHTING ROOM CONTROLLER DIAGRAM N.T.S. To Low Voltage Compartment of Associated Relay Panel - 1 Common - PLUS +1 per switch $. Low Voltage Switch it -Device TYPICAL WR-860x HARDWIRED SWITCH STATION CONNECTIONS j Line Voltage Master / Panel 1LCP Low Voltage jDtre Vattage CC NTROL ROOM Low Voltage IP Network - Ethernet 10Base T (by Others) MUM CI0 CI C u....u.uu.- •o •u. By Others SYSTEM NOTES: * REFER TO PLANS FOR EXACT LOCATION AND QUANTITY OF LOW VOLTAGE SWITCHES REQUIRED * NETWORK TOPOLOGY OPTIONS: - FREE -TOPOLOGY (STAR -CONFIGURATION) Max total wiring distance is 900FT without a repeaters Repeater locations to be determined by Factory Technician a r_n Z r m UCn c) Z ci 0 Z m n cn 0 Low Voltage Switch 3-Device n 1 m Low Voltage Switch 4-Device C Low Voltage Switch 8-Device 1 m icar- Typical Occupancy Detector C P- Typical Interior Daylight Sensor NC Typical Exterior Daylight Sensor 1 C To Low Voltage Compartment of Associated Relay Panel -\ LIGHTING CONTROL DIAGRAM 1 N.T.S. LEGEND #18AWG wiring required Recommend to add a minimum of 10% s 2 # 18AWG wiring required Recommend LVT or Bell Cable. iREVIEWED FOH COMPLIANCE WITH Ire rPccf1L cTtQr"sNEr N1n' 1 4 2018 Ethernet Cable Connection City of Tukwila Standard Cat-5e Cable with RJ-45 ConnecBUILDING DIVISION Crossover Cable Connection Crossover Cat-5e Cable with RJ-45 Connector. ELi 8-095 1 CITY NUS( 02 2018 PERMIT CENTER architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com 44-11Ar TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com iu Ol Wca 0 �� o 0 (n a) p1 m tp O 2Q VYINo i O0 �5gtr36�3�0.o� D T 0CC) Yw C) Li it, — VJ < tDlo -;:' P. W Q vF-o HVF-Hu. REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL DETAILS Drawing Number E6.O2 CIRCUIT LEGEND 1#, 2W+G (3 WIRES TOTAL) 3#, 4W+G (5 WIRES TOTAL) CKT ID RACEWAYM/IRE AMPS CKT ID CONDUIT AND WIRE BPS (A2] 3/4"C, 2#12, #12G 20 [A4] 3/4'C, 4#12, #12G 20 (B2) 3/4'C, 2#10, #10G 30 [B4] 3/4'C, 4#10, #10G 30 [C2] 3/4"C, 2#8, #10G 40 [C4) It, 4418, #10G 40 [D2] 3/4"C, 2#6, #10G 50 (04) It, 4#6, #10G 50 [E2] VC. 204, #10G 60 (E4) 1-1/4"C, 4#4, #106 60 [F2] VC, 2#4, #8G 70 [F4] 1-114"C, 404, #8G 70 [G2) 1-1/4'C, 2#2, #8G 80 [G4] 1-112'C, 44/2, #8G 80 [H2] 1-114"C, 2#2, #8G 90 [H4] 1-1/2"C, 482, #8G 90 IJ2] 1-114"C, 2#1, #8G 100 [J41 2"C, 4#1, #8G 100 [K2] 1-114'C, 2#1, #6G 125 (K4] 2"C. 4#1, #6G 125 [L2] 1-1/4'C, 2#1/0, #6G 150 [L4] 2'C, 44$l/0, #6G 150 [M2] 1-1/2"C, 2142/0. #66 175 [M4I 2"C, 4#2/0, #SG 175 [N2] 1-1/2'C, 2#3/0, #6G 200 [N4] 2"C, 4#3/0. #6G 200 [02] 2t, 2144/0, #4G 225 [041 2-1/2"C. 4#4/0, #4G 225 (P21 2-1/2'C. 2-250KCM, #4G 250 (P4] 3•C, 4-250KCM. #4G 250 [Q2] 2.12"C. 2-350KCM, #4G 300 (041 3"C, 4-350KCM, #4G 300 [R2] 2-SETS [2"C. 2#3/0. #3G) 400 (R4) 2-SETS [2-1/2"C, 4#3/0, #3G) 400 30, 3W+G (4 WIRES TOTAL) [S4) 2-SETS [3 C, 4-250KCM, #2G] 500 CKT ID CONDUIT AND WIRE S[T4] AMPCKT 2-SETS (at, 4-350XCM, #1G) 600 IA31 314'C, 3#12, #12G 20 [U4] 2-SETS [4"C, 4-500KCM, #1/0G] 700 (133] 3/4'C, 3#10, #10G 30 [V4] 3-SETS [3'C, 430OKCM, #1/0G] 800 IC3] 3l4"C, 3#8, #10G 40 [W4] 3-SETS [4 C, 4500KCM, #2/0G] 1000 I133] 1"C, 3#6, #1OG 50 (X4] 4-SETS [3'C. 4-350KCM, #3/0G) 1200 1E3] 1'C. 3414, #10G 60 (Y4] 4-SETS [4"C. 4S00KCM. #4/0G) 1600 [F31 1-114"C, 3#4, #8G 70 [24) 5-SETS [4"C, 4-600KCM, 250KCM G] 2000 [G3] 1-1/4•C, 302, #8G 80 480VA, 3#. TRANSFORMER PRIMARY (3W+G) [H3) 1-114'C, 3#2, #8G 90 CKT ID CONDUIT AND WIRE MAPS (J3] 1-12T, 3#1, #86 100 130H] VC, 3#4, #10G 60 [K3] 1-12"C, 3#1, #6G 125 [45H] 1-1/2"C, 3#1, #8G 100 [L31 1-12'C. 3#1/0, #6G 150 (75H] 1-12'C, 3#1/0, #6G 150 (M31 2'C, 3#2/0, #66 175 [112H] 7C, 3#3/0, #6G 200 [N3] 2"C, 3#3/0, #6G 200 (150H] 2-1/2"C. 3-250KCM, #4G 250 [03] 2"C. 3#410, #40 225 (225H] 2-SETS [2'C, 3#3/0, #3G] 400 (P3] 2.12"C. 3-250KCM, #46 250 [300H] 2-SETS [3•C, 3-350KCM, #161 600 [03] 2-1/2"C, 3-350KCM, #4G 300 [500H] 3-SETS [3"C, 3-300KCM, #1/0G] 800 [R31 2-SETS [7C, 3#310 #3G] 400 [750H] 4-SETS (3"C. 3-350KCM, #3/0G) 1200 [S31 2-SETS [2-1/2-C, 3-250KCM, #2G] 500 208Y/120V, 3►, TRANSFORMER SECONDARY (4W+G) [-3] 2-SETS [3'0, 3-350KCM, #1G] 600 CKT ID CONDUIT AND WIRE CKT AMPS [U31 2-SETS 13"C, 3-50OKCM, #1/0G] 700 [30L] 2'C, 4#1. #6G 100 [V3] 3-SETS [3'C, 3-300KCM, #1/061 800 (45L] 2"C, 401/0. #6G 150 [W3] 3-SETS [3t, 3-SOOKCM, #2/OG) 1000 [75L) 2-1/2"C, 444(0, #2G 225 (X31 4-SETS (3'C, 3350KCM, #3/0G) 1200 (112L] 2-SETS [2-12"C. 4#3/0, #110G] 400 [Y3] 4-SETS (4"C, 3SOOKCM, #4/0G] 1600 (150L] 2-SETS l3"C, 4-350KCM, #2/0G] 600 (Z3) 5-SETS [4"C, 3 600KCM, 250KCM G] 2000 [225L] 3-SETS [VC, 4-300KCM, #210G] 800 34. 4W+G (6 WIRES TOTAL) (200% NEUTRALS) (300L] 3-SETS [4t, 4-500KCM. #310G] 1000 [2E4] 1-12"C, 3#4, 2#441, #8G 60 [500L] 4-SETS (4"C, 4-600KCM. (WOG] 1600 (2N4] 3"C. 3-250KCM, 2-250KCM N, #1/0G 200 [750L] 6-SETS [4'C, 4-600KCM, 250KCM G] 2500 (2R4] 2-SETS [3'C, 3-250KCM, 2-250KCM N, #1/0G) 400 [2T4) 2-SETS (4"C, 3-50OKCM, 2-50OKCM N. #2J0G] 600 [2V4] 3-SETS [3-1/2"C, 3-400KCM, 2-400KCM N, #3/0G) 800 I • GNDD (E)PA (E)PA (E)PA 208/ 206/ 2081 120V 120V 120V SEC 1 SEC 2 SEC 3 XFMR (E)17 3P2 208/ 120V 200A MCB o[N4] (E LA 480/ 277V l (3)300 AF 400/3 (E)PC 208/ 120V SEC 1 (E)PC 208/ 120V SEC 2 200A ENCLOSED CIRCUIT BREAKER 1600A BUS I (E)MP 208/ 120V (E)M (E)M (E M 480/ 480/ 480/ 277V 277V 277V SEC 1 SEC 2 SEC 3 (3)600 AF 600/3 1 (E)MAIN SWITCHBOARD XFMR (E)TM (E)PE 208/ 120V (E)PD ' (E)PD (E C2 208/ 208/ 208/ 120V 120V 120V SEC 1 SEC 2 400A ENCLOSED CB (3)400 AF 400/3 XFMR (E)TKI 0 400A BUS (E)K 208/ 120V SEC 1 (E)K 208/ 120V SEC 2 (3)175 AF 200/3 (3)600 A 600/3 (E LF 480/ 27N /5-(3)200 AF 3E XFMR (E)TF (E PF 208/ 120V 200/3 1 (E) DISTRIBUTION PANEL 'DP' ( 600/3P 5(3)100 AF 100/3 1 1M2 208/ 120V 125A MCB 0D DO 0D o4K4] 1 0 U) 1L4 480/ 277V 200A MLO o4N4] 60A SPARE (3)60 AF (3)60 AF 60/3 60/3 I W41-o 0 a U) 1P2 SEC 1 208/ 120V 200A MCB 1P2 SEC 2 208/ 120V 200A MCB o{75L) XFMR T-1 P2 480V: 120/208V 75KVA o{75H] ELEV4 208/ 120V 60A MCB 2P2 208/ 120V 100A MLO 2P2 208/ 120V 30A MCB 0 C 400/3P XFMR T-ELEV2 480V: 120/208V 15KVA XFMR T-1Z2 460V: 120/208V 75KVA o475H] W Ce a m- ( 200/3P ( 100/3P C60/3P 100/3P C' 100/3P I I T DP-B 600A, 480Y/277V, 30, 4W, GENERAL NOTES 1. REFER TO PANEL SCHEDULES, SHEETS EX.XX - EX.XX, AND LIGHTING CONTROL PANEL RELAY SCHEDULES, SHEET EX.XX. PLAN NOTES O PROVIDE NEW 600A SWITCH WITH 600A FUSES IN EXISTING SWITCHBOARD. O INTERCEPT CIRCUITS FROM FREEZER AND WALK IN COOLER CURRENTLY ON PANEL K AND RE -SUPPLY THEM TO PANEL'1Z2' O PROVIDE 200 AMP DISCONNECT. O PROVIDE ENERGY SUB METERING. [75L]' [N4) NEC 702 SYSTEM 1Z2 208/ 120V 200A MCB [N4J o 0 1n ATS-Z 200A 3-POLES GENSET 4a(N41 rn 200AS LP 200A1- 0- [N4] START REVIEWED Nih COMPLIANCE WITh NFPA TO - NEC 200A BUSSED GUTT R GENERATOR G1 60KW, 208Y/120V, 30,4W L J NnV i 4 2018 City of Tukwila BUILDING DIVISIra NOV 02 2018 PERL"IT CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com V V TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J 0 UO 1.J_ /�� U o -Jo O 0 O 2 �Wz <QO 0o D CI H < REVISION DATE Design: Drawn: Checked: Project No. AH BT RA 180103 Issuance PERMIT SET Issue Date: 10-19-2018 Drawing Title ELECTRICAL ONE LINE DIAGRAM Drawing Number E7.01 TO UTILITY TRANSFORMER 2\ ELECTRICAL PARTIAL ONE LINE DIAGRAM NTS ELi 8-095 1 e I CLASSIFICATION: LOCATION: MOUNTING: PANEL "1P21" HOOL PROJECT: DISTRICT SHOWALTER.. NORMAL MECHANICAL/ELEC/CUST... VOLTAGE: 120/208 Wye MAINS: MCB NEUTRAL: 100.00% B 1080 1080 C 540 TYPE: AIC: FED FROM: NOTE CKT AMPS POLES A 720 POLES AMPS CKT NOTE CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION 1 CONTROLLED RECEPTACLES 20 A 1 1080 1 20 A CONTROLLED RECEPTACLES 2 3 RECEPTACLES 20 A 1 Y 1 20 A RECEPTACLES 4 5 CONTROLLED RECEPTACLES 20A 1 540 1 20A CONTROLLED RECEPTACLES 6 7 RECEPTACLES 20A 1 540 540 1 20A RECEPTACLES 8 9 CONTROLLED RECEPTACLES 20 A 1 900 900 1 20 A RECEPTACLES 10 11 RECEPTACLES 20 A 1 1080 360 1 20 A RECEPTACLES 12 13 CONTROLLED RECEPTACLES 20A 1 540 1000 1 20A REFRIGERATOR 14 15 RECEPTACLES 20A 1 540 900 1 20A CONTROLLED RECEPTACLES 18 17 CONTROLLED RECEPTACLES 20A 1 900 720 1 20A RECEPTACLES 18 19 RECEPTACLES 20A 1 900 810 1 20 A CONTROLLED RECEPTACLES 20 21 CONTROLLED RECEPTACLES 20A 1 540 630 • ?'; 1 20A RECEPTACLES 22 23 RECEPTACLES 20A 1 - 720 360 1 20 A RECEPTACLES 24 25 CONTROLLED RECEPTACLES 20A 1 540 900 day.:;° 1 20A RECEPTACLE 26 27 RECEPTACLES 20A 1 900 720 1 20A RECEPTACLE 28 29 30 31 32 33 34 35 38 37 PANEL 2P2 20 A 3 7920 - 38 39 - - - 6120 40 41 - - - 2520 42 TOTAL LOAD: 15490 VA 14310 VA 7740 VA TOTAL AMPS: 138 A 128 A 65 A LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY RECEPTACLE 37540 VA 83.32% 23770 VA TOTAL CONN. LOAD: 37540 VA TOTAL EST. DEMAND: 23770 VA TOTAL CONN. CURRENT: 104 A TOTAL EST. DEMAND... 66 A NOTES: CLASSIFICATION: LOCATION: MOUNTING: ' CKT 1 PANEL "2P2" PROJECT: DISTRICT SCHOOL H TER... NORMAL ELEC B203B VOLTAGE: 120/208 Wye MAINS: MCB NEUTRAL 100.00% TYPE: AIC: FED FROM: 1P21 NOTE CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE CONTROLLED RECEPTACLES 20A 1 1080 1080 1 20A CONTROLLED RECEPTACLES 2 3 RECEPTACLES 20A 1 720 720 1 20A RECEPTACLES 4 5 RECEPTACLES 20A 1 - 360 360 1 20A RECEPTACLES 6 7 CONTROLLED RECEPTACLES 20 A 1 1080 900 1 20 A CONTROLLED RECEPTACLES 8 9 RECEPTACLES 20 A 1 720 1080 1 20 A RECEPTACLES 10 11 RECEPTACLES 20A 1 360 360 1 20A RECEPTACLES 12 13 CONTROLLED RECEPTACLES 20 A 1 1080 900 - 1 20 A RECEPTACLE 14 15 RECEPTACLES 20A 1 720 720 1 20A RECEPTACLE 18 17 RECEPTACLES 20 A 1 360 360 1 20 A RECEPTACLE 18 19 CONTROLLED RECEPTACLES 20 A 1 1080 720 1 20 A RECEPTACLE 20 21 RECEPTACLES 20 A 1 720 720 1 20 A RECEPTACLE 22 23 RECEPTACLES 20 A 1 360 24 25 Spare 0 A 1 0 26 27 Spare OA 1 0 28 29 Spare 0 A 1 0 30 31 Spare 0A 1 0 - 32 33 Spare OA 1 0 34 35 Spare OA 1 0 36 37 Spare 0A 1 0 j -... 38 39 Spare OA 1 0 ...- 40 41 42 TOTAL LOAD: 7920 VA 6120 VA 2520 VA TOTAL AMPS: 71 A 56 A 21 A LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY RECEPTACLE 16560 VA 80.19% 13280 VA TOTAL CONN. LOAD: 16560 VA TOTAL EST. DEMAND: 13280 VA TOTAL CONN. CURRENT: 46 A TOTAL EST. DEMAND... 37 A NOTES: PANEL "1 P22" HOOL PROJECT: STTRRICCTLA SHOOWA TER... CLASSIFICATION: NORMAL LOCATION: MECHANICAL/ ELEC/CUST... MOUNTING: VOLTAGE: 120/208 Wye MAINS: MCB NEUTRAL: 100.00% TYPE: AIC: FED FROM: 1 P21 NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE 1 2 3 .: 4 5 6 7 8 g 10 11 12 13 14 15 16 17 18 19 20 21 i 22 23 24 25 26 27 _....._ 28 29 30 31 32 33 34 35 36 37 38 39 40 41 I 42 TOTAL LOAD: 0 VA 0 VA 0 VA TOTAL AMPS: OA 0A OA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY TOTAL CONN. LOAD: 0 VA TOTAL EST. DEMAND: 0 VA TOTAL CONN. CURRENT: 0 A TOTAL EST. DEMAND... 0 A NOTES: _ CLASSIFICATION: LOCATION: MOUNTING: PANEL "1 L4" PROJE .; TUKWILASCHOOL DISTRICT SHOWALTER.. NORMAL ELEC B203B VOLTAGE: 4801277 Wye MAINS: NEUTRAL: 100.00% TYPE: AIC: FED FROM: NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CrNOTE 1 LIGHTING - FIRST FLOOR 20A 1 1113 1027 1 20 A Lighting 2 3 LIGHTING - FIRST FLOOR 20 A 1 1795 1364 1 20 A Lighting 4 5 UGHTING - FIRST FLOOR CORRIDOR 20 A 1 828 1076 1 20 A Lighting 8 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 . .. 30 31 32 33 34 35 36 37 38 39 40 41 42 TOTAL LOAD: 2140 VA 3160 VA TOTAL AMPS: 8A 12A 1904 VA 7A LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY Lighting 7203 VA 125.00% 9004 VA TOTAL CONN. LOAD: 7203 VA TOTAL EST. DEMAND: 9004 VA TOTAL CONN. CURRENT: 9 A TOTAL EST. DEMAND... 11 A NOTES: PANEL "1M4" PROJECT: DISTTRICCTLA SCHOWAALTER.. CLASSIFICATION: NORMAL LOCATION: ELEC B2038 MOUNTING: VOLTAGE: 480/277 Wye MAINS: NEUTRAL: 100.00% TYPE: AC: FED FROM: NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 25 26 2, 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 TOTAL TOTAL LOAD: OVA AMPS: OA OVA OVA 0A 0A _ LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY TOTAL CONN. LOAD: 0 VA TOTAL EST. DEMAND: 0 VA TOTAL CONN. CURRENT: 0 A TOTAL EST. DEMAND... 0 A NOTES: PANEL "1 M2" L PROJECT: DIS RIOT LA SHOWALTFR... CLASSIFICATION: NORMAL LOCATION: ELEC B2038 MOUNTING: VOLTAGE: NEUTRAL: 120/208 MAINS: MCB 100.00% Wye TYPE: NC: FED FROM: NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE 1 2 3 4 8 5 7 8 10 9 12 11 14 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 38 37 38 39 40 41 42 TOTAL LOAD: 0 VA 0 VA 0 VA TOTAL AMPS: OA 0A 0A LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY TOTAL CONN. LOAD: 0 VA TOTAL EST. DEMAND: 0 VA TOTAL CONN. CURRENT: 0 A TOTAL EST. DEMAND... 0 A EL18-0951 REVIEWED FOrt COMPLIANCE WITS' NFPA 70 - NF(` WM 1 4 2018 CO of Tukwila BUILDING DIVISIC., CITY OF ?}- NUV 02 2018 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main St. Seattle, WA 98104 p. 206.624.4222 f. 206.624.4226 mail@rolludaarchitects.com TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 4626 S. 144TH STREET REVISION DATE Design: AH Drawn: AH Checked: SKF Project No. 331-17-01 Issuance PERMIT SET Date: 10-19-2018 Drawing Title ELECTRICAL PANEL SCHEDULES Drawing Number E7.02