Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL18-1016 - DXL - (2) EXISTING 200 AMP, 120/208 VOLT ELECTRICAL SERVICE TO REMAIN
DXL 17401 SOUTHCENTER PKWY 161 ELI8-1016 Parcel No: Address: City of Tukwila of Department '"-—'_.'^Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431'3670 Inspection Request Line: 206-438'9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 2623049120 Permit Number: EL18-1016 17401 SOUTHCENTER PKWY 161 Issue Date: 3/4/2019 Permit Expires On: 9/16/2019 Project Name: DXL Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WINNERS 3 LLC lI7ELOU8AST#Z30,SEATTLE, IL, 98102 KEVIN MCKENNA ll1W.WASHINGTON, STE45O' CHICAGO, IL, 60602 D C ELECTRIC INC 23l1763AVE VV'MOUNTLAKE TERRACE, WA, 98043 '^' Phone: (312) 260-7074 Phone: (206) 940-4963 Expiration Date: 8/18/2020 DESCRIPTION OF WORK (2) EXISTING 200 AMP, 120/208 VOLT ELECTRICAL SERVICE TO REMAIN Valuatio,, of single family: $0.00 Valuatiori of mf/comm: $32,835l0 Type of Work: TENANT IMP Fees Collected: $921.89 Electrical Servce Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: Internatiorial Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: Permit Center Authorized Signature: 2015 20152015 2015 2015 National ElectricaCode: WA Cities ElectricaCode: WAC 296-46B: 2017WA State Energy Code: 2017 2017 2015 � .�/-�/� Date: .v ~" | ( / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. .t.0111 Signatur Print Name: , ✓ c CJCa �Ai�2ar. Date: '1 -Qt- 11 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB Parcel No: Address: City of Tukwila a o of Department -"-—__-^Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206'431'3670 Inspection Request Line: 206'438-9350 Web site: http://www.TukwiIaWA.gov ELECTRICAL PERMIT 2623049120 Permit Number: EL18-1016 17401 SOUTHCENTER PKWY 141 Issue Date: 3/4/2019 Permit Expires On: 8/31/2019 Project Name: DXL Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WINNERS 3 LLC 1l7ELOUISAST#Z3O'SEATTLE, IL, 98102 KEVIN MCKENNA lllW.WASHINGTON, STE45V' CHICAGO, IL, 60602 D C ELECTRIC INC 23117 63 AVE W,M0UNDAKE TERRACE, WA, 98043 DCELE[|924mD '^' Phone: (312) 260-7074 Phone: (206) 9404963 Expiration Date: 8/18/2020 DESCRIPTION OF WORK: (2) EXISTING 200 AMP, 120/208 VOLT ELECTRICAL SERVICE TO REMAIN Valuation of single family: $0\00 Valuation of mf/comm: $32,835.00 Type of Work: TENANT IMP Fees Collected: 5921.89 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopteby the City of Tukwila: Interaational Building Code Edition: nternational Residential Code Edition: lnternational Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permft Center Authorized Signature: 2015 20152015 2015 2015 National Electrical Code: WA Cities ElectricaCode: WAC 296-46B: WA State Energy Code: 2017 20172017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per and agree to the cog: 'ions attached to this permit. Signature: Print Name: Date: 3-4-/-119 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300SouthcenterBlvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office fuse only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 17401 Southcenter Parkway Tenant Name: DXL King Co Assessor's Tax No.: 262304-9120 ,,1 Suite Number: 1 I 1 Floor: New Tenant: ❑ Yes ❑..No PROPERTY OWNER Name: Christian Schofield - Seattle Retail Address: 117 E Louisa Street #230 City: Seattle State: WA Zip: 98102 CONTACT PERSON — person receiving all project communication Name: Kevin McKenna - Burnham Nationwide Address: 111 W. Washington, Ste. 450 City: Chicago State: IL Zip: 60602 Phone: (312) 260-7074 Fax: Email: kmckenna@burnhamnationwide.com ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 32,835 Scope of Work (please provide detailed information): (2) existing 200 amp, 120/208 Volt electrical service to remaib Will service be altered? ❑ Yes ® No Adding more than 50 amps? Q Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition 0 Service Change 0 Remodel Ca Tenant Improvement ❑ Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: El Puget Sound Energy D Seattle City Light W:\Permit Center \Applications-Handouts\Perinit Appli Revised. January 2017 bh onsWDFs\Electrical Permit Application Revised 1-I-17.doca Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE 0 New single family dwellings $155.91 (including an attached garage) O Garages, pools, spas and outbuildings 583.54 ea O Low voltage systems (alarm, furnace thermostat) 561.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) O Service change with added/altered circuits number of added circuits ❑ Circuits added/altered without service change (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) 57.65 ea O Meter/mast repair 569.62 ❑ Low voltage systems 561.05 (alarm, furnace thermostat) 583.54 512.00 ea 555.69 MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) 582.52 ❑ Manufactured/mobile home service 587.98 (excluding garage or outbuilding) ❑ Carnivals 582.21 Number of concessions 511.02 ea Each ride and generator truck 511.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: `K'�-'`-^ Mailing Address: R t1 ‚-"J `'S Day Telephone: Date: t k U /1—D ( V TL C uc 6L W:\Permit Center \Applications-nadouas\P rmit ApplicationsT0Fs\Electrical Permit Revised. January 2017 bh n Revised 1-1-17 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $748.80 EL18-1016 Address: 17401 SOUTHCENTER PKWY 141 Apn: 2623049120 $748.80 Credit Card Fee $21.81 Credit Card Fee R000.369.908.00.00 0.00 $21.81 ELECTRICAL $692.37 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $692.37 TECHNOLOGY FEE $34.62 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17061 R000.322.900.04.00 0.00 $34.62 $748.80 Date Paid: Monday, March 04, 2019 Paid By: DANNY CASTOE Pay Method: CREDIT CARD 125926 Printed: Monday, March 04, 2019 10:53 AM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-187a CITY OF TUKWILA 0017340000802374464500 Date: 03/04/2019 VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: X 10:52:11 AM CREDIT CARD SALE **********7310 K $748.80 125926 000 Bill {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $1,722.01 PermitTRAK D18-0377 Address: 17401 SOUTHCENTER PKWY 141 Apn: 2623049120 $1,469.94 DEVELOPMENT $1,469.94 PLAN CHECK FEE I 8000.345.830.00.00 I 0.00 $1,469.94 EL18-1016 Address: 17401 SOUTHCENTER PKWY 141 Apn: 2623049120 $173.09 ELECTRICAL $173.09 PLAN CHECK FEE R000.345.832.00.00 0.00 $173.09 M18-0160 Address: 17401 SOUTHCENTER PKWY 141 Apn: 2623049120 $78.98 MECHANICAL $78.98 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15927 R000.322.102.00.00 0.00 $78.98 $1,722.01 Date Paid: Thursday, November 29, 2018 Paid By: DXL GROUP Pay Method: CHECK 411724 Printed: Thursday, November 29, 2018 9:09 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � � Type of Inspection: fAIkL / Address t NO 3 - c- py, Date Called: Special Instructions: Date Wanted: % ,� p.m. Requester: (/ Phone No: tit/Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee us be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD INSPE ION NO. Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: V. t., Type of I Cii Al nsPecti":40a1+ Address: - Py .. rili)( 5-C Date Called: Special Instructions: Date Wanted: a. p.m. Requester: z gkCe ..lf.,.._ Phone No: Approved per applicable codes. Corrections required prior to approval. tOMMENTS: z gkCe ..lf.,.._ 1 eat.me41 Le--, ...... Inspector: Date: T REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: NN Type of Inspectio iNi Address:j Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: 01/, 4t2r,itru9) ?A' Ins Date:©j , 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G%ls 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 614-tots Project: Type of Inspection: e Address:Date i7'o(S-G.. /)7 Called: Special Instructions: Date Wanted: a I"n Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (, J�A�^'" " AdL15 1 LC, J I< Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. ERMJT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: NI— Type of Inspection7K0144. td Address: /746,4 0.c., p/ - Date Called: .e, Special Instructions: Date Wanted: Requester: # 4 ttl--Yi Phone No: 7.42, 33( 376-0 proved per applicable codes. Corrections required prior to approval. COMMENTS: GJAue.016) Inspector: Date: 03/2.40/t REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. c PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-1016 DATE: 11/29/18 PROJECT NAME: DXL SITE ADDRESS: 17401 SOUTHCENTER PKWY #141 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: IP AT 42/1 Building Divisio Public Works Fire Prevention Structural Planning Division Permit Coordinator a PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/04/18 Structural Review Required REVIEWER'S INITIALS: DATE: r APPROVALS OR CORRECTIONS: DUE DATE 1/01/19 Approved Approved with Conditions n Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Ej Fire Ping El PW D StaffInitials: 12/18/2011 D C ELECTRIC INC ilonne Espanol Contact Safety & Health Claims & Insurance Washington State Department of `% Labor & Industries Search L&I Page 1 of 2 A-% Index 13elp \vin l / 1 Workplace Rights Trades & Licensing D C ELECTRIC INC Owner or tradesperson Principals CASTOE, DANNY, PRESIDENT CASTOE, HEATHER, SECRETARY CASTOE, HEATHER, AGENT CASTOE, HEATHER, PRESIDENT (End: 07/30/2012) Doing business as D C ELECTRIC INC WA UBI No. 602 848 189 23117 63RD AVE W MOUNTLAKE TERRACE, WA 98043 206-940-4963 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. DCELEEI924ND Effective — expiration 08/04/2008— 08/18/2020 Designated administrator CASTOE, DANNY A License type Electrical Administrator Bond AMERICAN CONTRACTORS INDEiN CO Bond account no. 100052096 Received by L&I 08/04/2008 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. Active. Meets current requirements. License no. CASTOD'98808 $4,000.00 Effective date 08/01/2008 Expiration date Until Canceled Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602848189&LIC=DCELEEI924ND&SAW= 3/4/2019 DEMOLITION NOTES 1. REFER TO ELECTRICAL DEMOLITION NOTES ON SHEET E4.0 FOR REQUIREMENTS. 2. EXISTING LIGHTING FIXTURES (NOT BEING REUSED) IN AREAS OF NEW WORK SHALL BE REMOVED COMPLETE WITH FIXTURE CONDUIT AND WIRE. EXISTING CONTROLS, SWITCHES, ETC SHALL BE REMOVED COMPLETE WITH DEVICE, CONDUIT, AND WIRE. LIGHTING PLAN - GENERAL NOTES 1. COORDINATE EXACT LOCATION OF ALL EXTERIOR FIXTURES AND DEVICES WITH ARCHITECTURAL DRAWINGS. 2. ALL WIRING SHALL BE RUN IN CONDUIT, MINIMUM SIZE CONDUIT FOR HOMERUNS IS 3/4" CONDUIT, ALL BRANCH CIRCUIT WIRING SHALL BE 2 #12 AND 1 #12 GROUND AWG. EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. 3. WIRE ALL NIGHT LIGHTS, EXIT SIGNS, AND EMERGENCY EGRESS FIXTURES AHEAD OF LIGHTING CONTROL AND SWITCHING. 4. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SO THAT INTERFERENCES BETWEEN CONDUITS, LIGHTING, EQUIPMENT, PLUMBING WORK, MECHANICAL WORK, AND BUILDING STRUCTURE WILL BE AVOIDED. 5, ALL LIGHT SWITCHES AND COVERS SHALL BE GRAY IN COLOR. LIGHTING PLAN KEYNOTES SEE LIGHTING CONTROL DIAGRAMS ON SHEET E3.1. COORDINATE PROGRAMMING SCHEDULE AND INSTRUCTIONS WITH OWNER. 'D2' LIGHT FIXTURES ARE PROVIDED BY TENANT. GC SHALL INSTALL IN MIRROR FIXTURE. w3 RELOCATE EXISTING SALES AREA LIGHT SWITCHES TO THIS LOCATION. PROVIDE LIGHTING CONTROL SWITCHES FOR NEW LIGHTING. COORDINATE LOCATION WITH FURNITURE AND GARY BERNSTEIN DISTRIBUTION AND CONTROL PRODUCTS, LLC. OFFICE: 617-823-8620 LIGHT FIXTURE TO BE USED FOR SECURITY LIGHTING PURPOSES. ROUTE TRACK LIGHTING CIRCUITS THROUGH CURRENT LIMITING PANEL. REFERENCE CURRENT LIMITING SUBPANEL SCHEDULE ON E3.0. PROVIDE PENDANT MOUNTED OCCUPANCY SENSOR MOUNTED AT HEIGHT OF LIGHT FIXTURES: INFRARED & ULTRASONIC 360 DEGREE OCCUPANCY SENSOR WATTSTOPPER: DT-305-COLOR-BZ50. PROVIDE ALL POWER PACKS, AND ADDITIONAL WIRING AS REQUIRED. COORDINATE WITH MANUFACTURER. SET OCCUPANCY SENSOR TIMER TO 15 MINUTES. PROPOSED SUBSTITUTIONS MUST BE SUBMITTED AND APPROVED BY DXL PROJECT MANAGER AT TIME OF BID. CEMERGENCY/EXIT LIGHTING IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. MAINTAIN EXISTING CONNECTIONS. CONTRACTOR TO TEST FUNCTIONALITY OF EXISTING EMERGENCY LIGHTING. PROVIDE UNIT PRICING TO REPLACE DAMAGED OR DEFECTIVE UNITS. REPORT ANY DEFICIENCY TO ENGINEER. VERIFY ADEQUATE GENERAL AND EMERGENCY LIGHTING EXISTS. REPORT ANY DEFICIENCY TO ENGINEER. LIGHTING NOTED IS EXISTING TO REMAIN. MAINTAIN EXISTING CIRCUITING AND CONTROL UNLESS NOTED OTHERWISE. CLEAN, REPAIR, AND RE -BALLAST AS REQUIRED. ALL EMERGENCY, NIGHT LIGHTS, AND EXIT LIGHTS TO BYPASS ALL SWITCHING. 10 LIGHTING NOTED IS EXISTING TO BE RELOCATED. EXTEND AND RECONNECT TO EXISTING CIRCUIT AND CONTROLS UNLESS NOTED OTHERWISE. CLEAN, REPAIR, AND RE -BALLAST AS REQUIRED. VERIFY FIXTURE QUANTITIES IN FIELD PRIOR TO BID. 11 CONNECT TO EXISTING STOCKROOM LIGHTING CIRCUIT. DO NOT LOAD LIGHTING CIRCUIT MORE THAN 80% RATED AMPERAGE PER BREAKER SIZE. NATIONAL LIGHTING ACCOUNT CONTACT: LIGHTING CONTROL PANEL AND CURRENT LIMITING GARY BERNSTEIN DISTRIBUTION AND CONTROL PRODUCTS, LLC OFFICE:617-823-8620 FAX: 617-846-1472 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR MOUNTING HEIGHTS OF ALL PENDANT LIGHT FIXTURES. "f El A-33 INDICATES PANEL CIRCUIT LIGHT FIXTURE IS TO BE PLACED ON. 1 EXISTING PANEL 'A' EXISTING PANEL 'B' NOTE: SEE SHEET A-2.1 FOR LIGHTING INSTALLATION DIMENSIONS LIGHTING PLAN 1/4" = 1'-0" FiL��`d� �0�(� Permit No. `C Plan review ap"ova! is subiect to errors anc omissions Approval of construction documents does -.ot autr: rize the viaafon of any - • •Dred code or ordinance-- - etDt of av td Copy and M By: LF.fr. .NL Date City of Tukwila BUILDING DIVISION i r No changes shall Pe made to the scope of work witnout prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review. i SEPARATE PERMIT RE UIRED,FOR: Mechanical 0 Electrical [G� plumbing TY Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOFt COMPLIANCE WITH NFPA70-NEC DEC 18 2((018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER Project Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 Issue Date Revisions Dote A A A A A A 11 /09/18 8 Descriptko Desc By Ja o 5K STORE 4 6 1 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL FAX WWW.SARGARCH.COM 1 DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering Engineers Job Number 0419871-002 Drawn BY MMM Appv d By. RM Sheet Title UGHT1NG PLAN Sheet Number E-1.0 NOTE: COORDINATE GENERAL RECEPTACLE LOCATIONS IN SALES AREA WITH WOOD AND CEMENT BOARD PANEL LOCATIONS ALONG WALLS. SEE SHEET E-2.1 FOR DATA/PHONE AND LOW -VOLTAGE CABLE. DEMOLITION NOTES 1, REFER TO ELECTRICAL DEMOLITION NOTES ON SHEET E4.0 FOR REQUIREMENTS. 2. EXISTING LIGHTING FIXTURES (NOT BEING REUSED) IN AREAS OF NEW WORK SHALL BE REMOVED COMPLETE WITH FIXTURE CONDUIT AND WIRE. EXISTING CONTROLS, SWITCHES, ETC SHALL BE REMOVED COMPLETE WITH DEVICE, CONDUIT, AND WIRE. LOW VOLTAGE WIRING SHALL BE REMOVED PER NEC 800.25. POWER PLAN - GENERAL NOTES 1. COORDINATE EXACT LOCATION OF ALL EXTERIOR FIXTURES AND DEVICES WITH ARCHITECTURAL DRAWINGS. 2. ALL WIRING SHALL BE RUN IN CONDUIT, MINIMUM SIZE CONDUIT FOR HOMERUNS IS 3/4' CONDUIT, ALL BRANCH CIRCUIT WIRING SHALL BE 2 #12 AND 1 #12 GROUND AWG. EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SO THAT INTERFERENCES BETWEEN CONDUITS, LIGHTING, EQUIPMENT, PLUMBING WORK, MECHANICAL WORK, AND BUILDING STRUCTURE WILL BE AVOIDED. 4. ALL OUTLETS AND OUTLET COVERS SHALL BE GRAY IN COLOR. + $ 44 4°4 ►I► ;;4 40 44 00 1) 4; POLO SIGN j �:- t NO ELECTRICAL WORK IN HATCHED AREA j—SECURITY ALARM TYP) KEYPAD 2 B-40,42 A-26 15 A-28 — A-40 1 A-38 I A-36 ISTING PANEL 'A' (STING PANEL 'B' B-2 POWER PLAN 1/4" = 1'-0" POWER PLAN KEYNOTES <> LOCATION OF TENANT ELECTRICAL DISTRIBUTION EQUIPMENT. SEE SHEET E3.0 FOR RISER DIAGRAM. 12 RECEPTACLE MOUNTED JUST ABOVE WALL BASE. BOTTOM OF OUTLET COVER SHALL BE ABOVE BASE. (BY T.G.C) 0, PROVIDE RECEPTACLE FOR REFRIGERATOR. COORDINATE EXACT LOCATION IN FIELD. 13 PROVIDE (1) QUAD RECEPTACLE FOR TELEPHONE SYSTEM AND (1) QUAD RECEPTACLE WITH RJ31X JACK FOR ALARM PANEL. SEE RISER ON SHEET E3.0 FOR MORE INFORMATION. 33 WEATHERPROOF JUNCTION BOX AND SNAP SWITCH FOR FUTURE STOREFRONT SIGN COORDINATE REQUIREMENT WITH SIGN VENDOR. WIRE THROUGH 24 HR, 7 -DAY 2 CIRCUIT 14 PUSH BUTTON AT 48" A.F.F. FOR SERVICE DOOR. CONNECT TO BUZZER AS INDICATED. TIMECLOCK FOR CONTROL. 15 INSTALL BUZZER ABOVE CEILING WHERE SHOWN. CONNECT TO PUSHBUTTON AT REAR DOOR. C> FOR DATA OUTLET LOCATIONS, SEE SHEET E-2.1. 16 PROVIDE NEW TELEPHONE JACK AT LOCATION SHOWN. JACK SHALL BE MOUNTED BELOW SURFACE OF 5 PROVIDE 20AMP/1 PH (5-20R) RECEPTACLE FOR TAILOR SHOP EQUIPMENT. CASHWRAP/BACKWRAP. VERIFY THAT SCREWS ARE NOT TOO LONG SO AS TO DAMAGE EXTERIOR OF MILLWORK WHEN SCREWS ARE TIGHTENED, VERIFY BOTH POWER AND DATA ARE BELOW 6 PROVIDE DATA AND OUTLET BELOW FOR CORDLESS PHONE. DATA SHOWN ON SHEET E-2.1. COUNTERTOP. 7 PROVIDE DUPLEX RECEPTACLE AND DATA OUTLET AT 6'-6" A.F.F. FOR POWER AND DATA AT THE 17 ROUTE (2) 3/4" CONDUITS DOWN WALL. SEE SHEET E-2.1 FOR DATA LOCATION. WALL MOUNTED TELEVISION. SEE SHEET E-2.1 FOR DATA. 18 AIR CURTAIN, 208V, 1 PH, BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL MAKE 0. PROVIDE QUAD RECEPTACLE OUTLET AT 86" A.F.F. FOR POWER TO THE MONITOR. POWER FINAL CONNECTION. COORDINATE WITH EQUIPMENT SUPPLIER. VERIFY EXACT LOCATION WITH OUTLETS TO BE RECESSED IN WALL BEHIND MONITOR. COORDINATE TYPE WITH DXL MECHANICAL CONTRACTOR. PROVIDE 30A/2P NON-FUSED DISCONNECT AT UNIT AS REQUIRED. CONSTRUCTION REPRESENTATIVE. 19 IF NOT EXISTING, PROVIDE WP, GFI DUPLEX RECEPTACLE AT ROOFTOP HVAC EQUIPMENT. 0, , ROUTE (5) 3/4" CONDUITS DOWN WALL AND INTO FIXTURE FOR POWER AND TELE/DATA AT FRONT WRAP. 10 HVAC UNITS AND ALL ASSOCIATED ELECTRICAL COMPONENTS, DUCT SMOKE DETECTORS, RECEPTACLES, CONDUITS, FEEDERS, DISCONNECT SWITCHES, ETC. ARE EXISTING TO REMAIN. MAINTAIN EXISTING ELECTRICAL CONNECTIONS AND CONTROL. 11 SHOW WINDOW RECEPTACLES ARE EXISTING IN CEILING. MAINTAIN EXISTING CIRCUIT AND CONTROL. PROVIDE NEW AS REQUIRED PER NEC 210.62. FLOOR -J J CASHWRAP ELECTRICAL ELEVATION SCALE: N.T.S. -4SVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 18 2010 City of Tukwila @UILDING DNISION RECEIVED CITY OF TUKWILA NOV 2 9 2018 PERMIT CENTER Project Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 Issue Dote 11/09/18 Revisions Date A Descriptke By 5K STORE 4 6 1 FROM ROAD PARAMUS, NJ 07652 9 7 3. 2 5 3. 9 3 9 3 TEL 9 7 3. 2 5 3, 9 3 9 0 F A X WWW.SARGARCH.COM 1,,g I DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465,7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering Engineers Job Number 0419871-002 Drawn By. YAWN Appy d BF RMS Sheet title POWER PLAN Sheet Number E-2.0 0 POLO 0 SIGN T-1 (3) LINES FROM.O. PATCH PANEL • • • LOCATION. SEE SCHEDULE PATCH ANEL DMARK (3) LINES FROM PATCH PANEL LOCATION. SE SCHEDULE I L I I I_ I I I I l I l l I NETWORK AND TELEPHONE SCHEDULE (5K STORE) CABLE NAME FROM TO INSTALL LOC. CABLE RUN BY CABLE TERMINATED BY COMMENTS D1 PATCH PANEL AT BACKBOARD CASHWRAP FRONT CASHWRAP TELE/DATAVENDOR TELE/DATAVENDOR POS REGISTER 1 D2 PATCH PANEL AT BACKBOARD CASHWRAP FRONT CASHWRAP TELE/DATA VENDOR TELE/DATAVENDOR POS REGISTER 2 D5 PATCH PANEL AT BACKBOARD CASHWRAP FRONT CASHWRAP TELE/DATA VENDOR TELE/DATAVENDOR LASER PRINTER D6 PATCH PANEL AT BACKBOARD BACKWRAP BACKWRAP TELE/DATAVENDOR TELE/DATAVENDOR DESKTOP PC D7 PATCH PANEL AT BACKBOARD BACKWRAP BACKWRAP TELE/DATAVENDOR TELE/DATAVENDOR SPARE D8 PATCH PANEL AT BACKBOARD MANAGER'S OFFICE MANAGER'S OFFICE TELE/DATAVENDOR TELE/DATAVENDOR DESKTOP PC D9 PATCH PANEL AT BACKBOARD MANAGER'S OFFICE MANAGER'S OFFICE TELE/DATAVENDOR TELE/DATAVENDOR COLOR PRINTER D10 PATCH PANEL AT BACKBOARD PC PC STAND TELE/DATA VENDOR TELE/DATA VENDOR PC STAND © SALES FLOOR 011 PATCH PANEL AT BACKBOARD CEILING AREA CEILING AREA TELE/DATA VENDOR TELE/DATA VENDOR WIRELESS ACCESS POINT (WAP) TS1 TELEPHONE SYSTEM CASHWRAP - END NEAR STORE ENTRANCE JACK MOUNTED IN CASHWRAP TELE/DATAVENDOR TELE/DATAVENDOR CORDED HANDSET TS2 TS3 TELEPHONE SYSTEM BACK WRAP JACK MOUNTED IN BACKWRAP TELE/DATAVENDOR TELE/DATAVENDOR CORDLESS HANDSET TS4 TELEPHONE SYSTEM MANAGER'S OFFICE WALL JACK NEAR MANAGER'S DESK TELE/DATAVENDOR TELE/DATAVENDOR CORDED HANDSET TS5 TELEPHONE SYSTEM FITTING ROOMS FR CLOSET OR ADJACENT TO FR TELE/DATAVENDOR TELE/DATAVENDOR CORDLESS HANDSET TS6 TS7 TELEPHONE SYSTEM TAILOR AREA WALL JACK IN TAILOR AREA TELE/DATAVENDOR TELE/DATAVENDOR CORDED HANDSET TS8 LOW -VOLTAGE PLAN 1/4" = 1'-0" 12 PORT PATCH PANEL BY COMMWORKS LOCATED N STOCKROOM BY DMARK D1 D2 DC3 040D5 D6 D8 D9 D10 D11 fi LOW VOLTAGE - PLAN KEYNOTES GENERAL CONTRACTOR TO ROUTE (5) 3/4" CONDUITS DOWN WALL AND INTO FIXTURE FOR POWER AND TELE/DATA AT FRONT WRAP. TELEPHONE/DATA VENDOR TO ROUTE ALL DATA LINES FROM PATCH PANEL MOUNTED IN STOCKROOM. TELEPHONE/DATA VENDOR SHALL PROVIDE (1) RJ31X JACK ADJACENT TO ALARM PANEL. DATA JACK SHALL BE WIRED INTO TS1 PHONE LINE. LOCATION OF TELEPHONE BOARD. ALL TELEPHONE WIRES SHALL BE PULLED FROM THIS LOCATION. SEE ELECTRICAL RISER ON SHEET E3.0 FOR MORE DETAILS. MUSIC VENDOR SHALL RUN LINE FROM PHONE BOARD TO MUSIC SYSTEM. AL1 REV T �gl1tOF CONFPANEDFE70 -NEC DEC 1 8 2018 City of Tukwila QUILDING DNISICN RECEIVED CITY OF TLIKWILA NOV 2 9 2018 PERMIT CENTER Prot Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 , WA98188 Issue Date I 11/09/18 Revisions Date A Description By L nn iii 00 Z ova 1 1 cp 1 ISI ) U o c < O �.cct or) 5K STORE 4 6 1 FROM ROAD PARAMUS, NJ 07652 9 7 3. 2 5 3. 9 3 9 3 TEL FAX WWW.SARGARCH.COM DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465,7550 FAX 612.465.7551 WEB dunhameng com mechanical + electrical consulting engineering Engineers Job Number 0419871-002 Drown By. MA Appy d By. BMS Sheet Title LOW VOLTAGE PLAN Sheet Number E-2.1 Panel : PANEL A Voltage: 120/208V, 3PH, 4W No. Amp/p Note Description Ph Code L VA Code C VA Code R VA Code M VA Code E VA Code K VA Code D VA 1 20/1 1.00 BACKWRAP IG RECEPTACLES - A - 1.5 360 1.5 TOTAL 45.5 CHAIIEL 1 45.5 3 20/1 3 BACKWRAP RECEPTACLES - B - EXISTING LIGHTS WEST 360 864 CHANNEL 1 5 20/1 5 SECURITY EQUIPMENT - C - EXISTING LIGHTS WEST 360 864 120V EXISTING SALES FLOOR 2x4 UGH1ING CHAIREL 1 7 40 7 RTU -3 -EX (E) - A - EXISTING RTU -1 (E) -A - ZOE 2 3543 4395 9 / 9 " -B- TRACK UGHTING - B - 10 3543 120V 4395 TRACK UGHTTNG 11 3 11 If -C- TRACK UGHT1NG -C- 12 3543 120V 4395 TRACK UGHTING 13 20/1 13 RTU -RECEPTACLE -A - EXISTING RTU -1 RECEPTACLE 180 CHANNEL 1 180 ZONE 3 120V 15 20/1 15 EXISTING CIRCUIT - B - DISPLAY LIGHTS - B - 360 16 ZOE 3 120V 17 20/1 17 EXISTING CIRCUIT - C - EXISTING LIGHTS EAST - C - 360 1 18 ZONE 3 120V 19 20/1 19 EXISTING CIRCUIT - A - EXISTING LIGHTS (NIGHT E) - A - 360 CHAt091 1 20 ZONE 3 120V 21 20/1 21 DISPLAY LIGHTS - B - EXISTING LIGHTS EAST - B - 360 SHOW =COW LGHTIM 2 22 ZONE 1 23 20/1 23 SALES AREA RECEPTACLES - C - TRACK LIGHTING 720 470 Std SCOW RECEPTACLES CHANEL 3 24 ZOE 1 25 20/1 25 CASHWRAP - A - TRACK LIGHTING 360 750 EXITING SECURITY LICHT CHNOEL 4 26 27 20/1 27 CASHWRAP - B - TRACK LIGHTING 360 895 4 28 29 20/1 29 SALES AREA RECEPTACLES - C - TRACK LIGHTING 720 525 31 20/1 31 SALES AREA RECEPTACLES - A - SPACE 540 33 20/1 33 FITTING ROOM RECEPTS - B - SPACE 540 35 20/1 35 PHONE/ALARM RECEPTS - C - SPACE 720 37 20/1 37 REFRIGERATOR - A - SPACE - A - 1500 39 20/1 39 FLOOR FIXTURE - B - SPACE 1000 41 - 41 SPACE - C - SPACE - C - 2 20/1 2 MANAGERS IG - A - SIGN 360 1200 4 20/1 4 MANAGERS IG - B - SPARE 360 6 20/1 6 REFRIGERATOR - C - SPARE - C - 1500 8 40 8 EXISTING RTU -4 - A - EXISTING RTU -2 (E) - A - 3543 3543 10 / 10 / -B- - B - 3543 3543 12 3- 12 3II C - -C- 3543 3543 14 20/1 14 EXISTING RTU -4 RECEPTACLE - A - EXISTING RTU -2 RECEPTACLE 180 180 16 20/1 16 EXISTING WATER HEATER - B - EXISTING LIGHTING PANEL - B - 1500 18 20/1 18 EXISTING DETEX - C - LIGHTING CONTROL PANEL - C - 100 20 20/1 20 EXISTING BATH RECEPTS - A - 360 22 20/1 EXIST. SHOW WINDOW RECEPTS. - WES - B - MONITOR - B - 700 24 20/1 24 20/1 - C - FLATSCREEN TV - C - 700 26 20/1 26 20/1 - A - MANAGERS RECEPTS - A - 180 28 - 28 20/1 - B - MANAGERS RECEPTS - B - 360 30 - 30 20/1 - C - STOREFRONT RECEPTS - C - 720 32 - 32 20/1 - A - STOREFRONT RECEPTS - A - 720 34 - 34 20/1 - B - SEWING MACHINES - B - 1500 36 - 36 20/1 - C - BOILER & IRON - C - 1800 38 - 38 20/1 - A - VACUUM TABLE -A - 1245 40 15/ 40 20/1 - B - SUPER CREASE - B - 360 42 2- 42 - C - SPACE - C - 176 Through Feed Connection - Through - Feed Lug Connection -- -- - A - Lug ' None - B - -- - C - Main Breaker -- - A - 3828 3240 3105 7086 None - B - 2857 4840 2920 7086 - - C - 2973 3240 4360 7086 a ker Notes: Conn KVA phase loads Total - A - - B - - C - 1 - LOC - PROVIDE CIRCUIT BREAKER LOCK -ON DEVICE 43.0 13.4 14.8 14.7 2 - 2 - Dmd Conn • Bus KVA loads 3 - Panel - Bus KVA loads 3 - Code L 'Lighting 4 - 10 11 11 Code C7 Convenience Receptacles (180 W) 5 - 3 10 10 Code R = Receptacles (Non Convenience) board Notes: 24 21 Code M" Motors Largest motor VA 10628.0 1 - (E) INDICATES EXISTING EQUIPMENT AND LOAD TO REMAIN. CIRCUIT NUMBERS SHOWN FOR REFERENCE 27 24 Code E.! Electric Heat Code K1- Kitchen Equip Demand 100%' 2 - 3 - Code E'- Electric Heat Code D7 Dwelling Units (Hotel/Motel Rooms) 4 - 45 43 Total KVA 5 - 3 - + Spare KVA %Spare EXISTING : Mounting 45 Adjusted KVA (Demand KVA + Spare KVA) EXISTING : Amps AIC Rating 125 Adjusted Demand Amps 200 : Amp Rating of Bus 131 High Phase Demand Amps 8 -Nov -18 ' 200 : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name : 208 : Phase to Phase Voltage PANEL A 0419871-002 DXL ELECTRICAL LOAD SUMMARY - A LOAD TYPE CONNECT. LOAD (KW) DEMAND FACTOR DEMAND LOAD (KW) LIGHTING 0.0 1.25 0.0 RECEPTACLES 20.0 1.00 20.0 H.V.A.C. 24.0 1.00 24.0 WATER HEATER 1.5 100% 1.5 TOTAL 45.5 CHAIIEL 1 45.5 SERVICE SIZING LOAD = 45.5 KW 45.5 ® 208V/3PH = 126 AMPS Panel : PANEL B Voltage: 120/208V, 3PH, 4W No. Amp/p Note Description Ph Code L VA Code C VA Code R VA Code M VA Code E VA Code K VA Code D VA 1 20/1 WATER HEATER EXISTING LIGHTS (NIGHT W) - A - 864 TOTAL 40.0 CHAIIEL 1 42.0 ZOE 1 120V 3 20/1 CHANNEL 1 EXISTING LIGHTS WEST - B - 864 CHANNEL 1 5 ZONE 2 5 20/1 FITTING ROM LlGH1S EXISTING LIGHTS WEST - C - 864 120V EXISTING SALES FLOOR 2x4 UGH1ING CHAIREL 1 7 ZONE 2 7 40 EXISTING RTU -1 (E) -A - ZOE 2 120V 4395 CHANIEL 1 9 9 / B-23 TRACK UGHTING - B - 10 ZONE 3 120V 4395 TRACK UGHTTNG CHANNEL 1 11 11 3II B-27 TRACK UGHT1NG -C- 12 ZOE 3 120V 4395 TRACK UGHTING CHAIDEL 1 13 20/1 120V EXISTING RTU -1 RECEPTACLE - A - CHANNEL 1 180 ZONE 3 120V CHNOEL 1 15 20/1 120V DISPLAY LIGHTS - B - 234 16 ZOE 3 120V 17 20/1 ZOE 3 EXISTING LIGHTS EAST - C - 864 1 18 ZONE 3 120V A-36 I3IXER & 0NI 19 20/1 ZONE 3 EXISTING LIGHTS (NIGHT E) - A - 864 CHAt091 1 20 ZONE 3 120V A-40 SUPERCREASE 21 20/1 21 EXISTING LIGHTS EAST - B - 864 SHOW =COW LGHTIM 2 22 ZONE 1 120V B-20 23 20/1 23 TRACK LIGHTING - C - 470 Std SCOW RECEPTACLES CHANEL 3 24 ZOE 1 120V 13-2 25 20/1 4 TRACK LIGHTING - A - 750 EXITING SECURITY LICHT CHNOEL 4 26 ZONE 1 120V 27 20/1 SHAWL 4 TRACK LIGHTING - B - 895 4 28 ZONE 1 120V 29 20/1 TRACK LIGHTING - C - 525 31 - SPACE - A - 33 - SPACE - B - 35 - SPACE - C - 37 - SPACE - A - 39 - SPACE - B - 41 - SPACE - C - 2 20/1 SIGN -A - 1200 4 20/1 SPARE - B - 6 20/1 SPARE - C - 8 40 EXISTING RTU -2 (E) - A - 3543 10 / - B - 3543 12 3II -C- 3543 14 20/1 EXISTING RTU -2 RECEPTACLE - A - 180 16 20/1 EXISTING LIGHTING PANEL - B - 18 20/1 LIGHTING CONTROL PANEL - C - 100 20 20/1 EXIST. SHOW WINDOW RECEPTS. - EAS - A - 1260 22 20/1 EXIST. SHOW WINDOW RECEPTS. - WES - B - 900 24 20/1 FITTING ROOM LIGHTS - C - 150 26 20/1 FITTING ROOM LIGHTS - A - 150 28 - SPACE - B - 30 - SPACE - C - 32 - SPACE - A - 34 - SPACE - B - 36 - SPACE - C - 38 - SPACE - A - 40 15/ AIR CURTAIN - B - 176 42 2- C - 176 Through Feed Connection - -- -A - Lug ' None - B - -- - C - Main Breaker --- - A - 3828 1620 7938 None -B - 2857 900 8114 - - C - 2973 8114 Breaker Notes: Conn KVA phase Toads Total - A - - B - - C - 1 - PROVIDE GFI CIRCUIT BREAKER 36.3 13.4 11.9 11.1 2 - Dmd Conn Panel - Bus KVA loads 3 - 12 10 Code L Lighting 4- 3 3 Code C 7 Convenience Receptacles (180 W) 5 - Code R ' Receptacles (Non Convenience) Panelboard Notes: 27 24 Code M" Motors Largest motor VA 13185.0 1 - Code E'- Electric Heat 2 - Code K'- Kitchen Equip Demand 100%' 3 - Code DDwelling Units (Hotel/Motel Rooms) 4 - 42 36 Total KVA 5 - + Spare KVA %Spare ' EXISTING : Mounting 42 Adjusted KVA (Demand KVA + Spare KVA) EXISTING : Amps AIC Rating 117 Adjusted Demand Amps 200 : Amp Rating of Bus 128 High Phase Demand Amps 8 -Nov -18 200 : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name 208 1: Phase to Phase Voltage PANEL B 0419871-002 DXL ELECTRICAL LOAD SUMMARY - B LOAD TYPE CONNECT. LOAD (KW) DEMAND FACTOR DEMAND LOAD (KW) LIGHTING 10.0 1.25 12.0 RECEPTACLES 3.0 1.00 3.0 H.V.A.C. 27.0 1.00 27.0 WATER HEATER 0.0 100% 0.0 TOTAL 40.0 CHAIIEL 1 42.0 SERVICE SIZING LOAD = 42.0 KW 42.0 ® 208V/3PH = 116 AMPS EXISTING LANDLORD DISTRIBUTION CENTER 1600A, 120/208V 31), 4W o ) ( 0 ) I o `MSI o `MSI 0 0 M 1 0 M 1 I • CURRENT LIMITING SUBPANEL ORCUIT NUMBER CORRESPONDING WATTS AMPS B-23 470 5 A B-25 750 8 A B-27 895 10 A B-29 525 6 A NOTE CIRCUITS TO HAVE APPROXIMATELY 20% SPARE CAPACITY. JKATMNAL ACCOUNT CONTACT UGHTING CONTROL PANEL AND CURRENT L T=VG PANEL GARY BERNSTdN DISTRIIit111ON AND CONTROL PRODUCTS, LLC OFFICE: 617-823-8620 FAX: 617-846-1472 ALL EXISTING ELECTRICAL INFORMATION SHALL BE VERIFIED IN FIELD PRIOR TO START OF CONSTRUCTION. EXISTING 200A DISCONNECT AND METER TO REMAIN EXISTING 1600A MAIN DISCONNECT cr EXISTING PANEL A FLOOR EXISTING 2" C. 4#3/0, #6G & #6 IG EXISTING 2" C. 4#3/0, #6G EXISTING PANEL B LIGhTING DELAY 5ChEDULE #1 CHANNEL RELAY CONTROL LOAD CONTROL BUTTON Mme. CONTROL BUTTON VAC COM # LOAD CHANEL 1 1 ZONE 1 120V B-24 FITTING ROOM UGHTING CHNIEL 1 2 ZONE 1 120V EXISTING SALES FLOOR 2x4 LIGHTING CHAIIEL 1 3 ZOE 1 120V CHANNEL 1 4 ZONE 1 120V CHANNEL 1 5 ZONE 2 120V 8-26 FITTING ROM LlGH1S CHANEL 1 6 ZOE 2 120V EXISTING SALES FLOOR 2x4 UGH1ING CHAIREL 1 7 ZONE 2 120V CHAIREL 1 8 ZOE 2 120V CHANIEL 1 9 ZOE 3 120V B-23 TRACK UGHTING CHAIREL 1 10 ZONE 3 120V B-25 TRACK UGHTTNG CHANNEL 1 11 ZONE 3 120V B-27 TRACK UGHT1NG CHAIM 1 12 ZOE 3 120V B-29 TRACK UGHTING CHAIDEL 1 13 ZONE 3 120V 8-15 SALES DISPLAY LIGHTING CHANNEL 1 14 ZONE 3 120V CHNOEL 1 15 ZOE 3 120V CHAIM 1 16 ZOE 3 120V CHAIREL 1 17 ZOE 3 120V A-34 SEM MACIOES 1 18 ZONE 3 120V A-36 I3IXER & 0NI CHAIM 1 19 ZONE 3 120V A-38 VACCUU TABLE CHAt091 1 20 ZONE 3 120V A-40 SUPERCREASE CHAIM 2 21 ZONE 1 120V B-29 SHOW =COW LGHTIM 2 22 ZONE 1 120V B-20 SHOW RECEPTACLES CHANEL 2 23 ZOE 1 120V B-22 Std SCOW RECEPTACLES CHANEL 3 24 ZOE 1 120V 13-2 STORE FRONT SIGN 4 25 ZONE 1 120V EXITING SECURITY LICHT CHNOEL 4 26 ZONE 1 120V SHAWL 4 27 ZONE 1 120V 4 28 ZONE 1 120V NOTE: VERIFY TIME CLOCK SCHEDULE WITH OWNER AND LANDLORD. 1" CONDUIT TO BASE TELEPHONE DISTRIBUTION ALARM SYSTEM ENCLOSURE (12.5"x9.5") LIGHTING CONTROL SYSTEM/ CURRENT LIMITING (BY T.G.C.) PHONE SYSTEM ENCLOSURE (21"x15") QUAD RECEPTACLE FOR PHONE SYSTEM 24 PORT PATCH PANEL. LOWELL WALL -MOUNTED SHELVE MODEL FS18-16. PATCH PANELING WIRE UNIT TO BE MOUNTED BELOW SHELF FOR EASE OF CABLEING BETWEEN PATCH PANEL AND NEWTOWRK SWITCH DEVICE. QUAD RECEPTACLE AND RJ31X JACK FOR ALARM SYSTEM EXISTING TO 5- -•-•-•-•-•-•- UTILITY EXISTING 200A DISCONNECT AND METER TO REMAIN FIELD VERIFY SIZE OF EXISTING CONDUIT & CONDUCTORS AND REUSE IF SIZES MEET THOSE LISTED ABOVE. T.G.C. SHALL VERIFY ALL ELECTRICAL REQUIREMENTS OF EXISTING MECHANICAL EQUIPMENT (HVAC, ETC.). INFORMATION SHOWN ON PANEL RISER AND SCHEDULE IS FOR REFERENCE ONLY. T.G.C. SHALL ADJUST WIRE SIZE, BREAKER SIZE, DISCONNECT SWITCH, ETC., AS REQUIRED PER MANUFACTURER'S SPECIFICATIONS. POWER RISER DIAGRAM SCALE: N.T.S. RISER LEGEND DASH DOT LINE TYPE INDICATES EXISTING EQUIPMENT TO REMAIN. CONTINUOUS LINE TYPE INDICATES NEW EQUIPMENT TO BE INSTALLED BY CONTRACTOR REVIEWED FOR COMPLIANCE WITH NFPA70-NEC DEC 18 2018 City of Tukwila QUILDING DIVISION CITY OF TUK WILA NOV 292018 PERMIT CENTER Project Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 Issue Dote 11/09/18 Revisions Dote Q A Descrkgion By 0 (/) n SO THCE\T_R oo oo 7c)-6 67 J 5K STORE 4 6 1 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 F A X WWW.SARGARCH.COM MI DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering Engineers Job Number 0419871-002 Drawn By. MMM Appv d By. RM Sheet Title ELECTRICAL SCHEDULES AND RISER Sheet Number E-3.0 LiGhTING SPECIFICATION MARK TYPE MANUFACTURE CATALOG NUMBER DESCRIPTION TRIWCOLOR VOLT TOTAL WATTS MOUNTING LAMP REMARKS 0 C -LED MC C8H-226/42T-C852-CL-WH BLOCATIIN RECESS AREA GHT 2-42 WATT CFL WHITE MI 94 RECESSED CF42DT/E/D�3s WERAV' LIGHTDM USEWITHCLOSED CEILING SALES AREA --fi---0-1 13 0 --}E327 ----0 la 8 s SS/tii"8 LOUT 1x14 o f mLI2011.- 1 14 8 CE -LED JUDO C8H-226/42T-C852-CL-VH 8' DIA RECESS DOVR6_IGHT 2-42 VATT CFLt2) LICATIN SALES AREA WHITE M I 94 RECESSED CF42DT/E/IN835 GENERAL LIGHTING USE WITH CLasED CEILING SALES AREA O D D -LED MY C6V-126/42T C600 -CL -WH 6' DIA 1 42WATT C O JPACT FLUO T RECESSED DOWN UGHT SOFT FLOW REFLECTOR. WHITE UNI 42 RECESSED USHIO OPEN UCLOUD A SSG FLOOR ® DE -LED MY C6V-126/42T Et 0600 -42 -CS 6' DIA 1 42WATT COMPACT FLUORESCENT RECESSED DOWN UGHT SOFT FLOW REFLECTOR WITH EUERGENCY BATTERY PACK WHITE UNI 42 RECESSED USHiO USE IN OPEN CEIUNG CLOUD AREA SALES FLOOR Q D2 -LED ,Its 267E -WH RECESSED DOWN UGHT WHITE UNI 75 RECESSED 75PAR30 5 WAY MIRROR EM2 NAWJIE N2WH DUAL HEAD UNIVERSAL HIGH WATTAGE EMERGENCY LIGHT WHITE UNI 0 UNIVERSAL INCLUDED BACK OF HOUSE EMERGENCY 42, • • E1113 EI ERQ-U1E PROVIDER SERIES EMERGENCY LIGHT WHITE 120 12 UNIVERSAL INCLUDED SALES AREA EX1 NAVXJIE NXECR61RWtl EDGE UT LED EXIT SIGN WALL MOUNTED REDSALES LETTERS ON A WHITE BACKGROUND. Il ON RED UNI 0SSED WALL LED/ INCLUDED AREA WALL MOUNTED 0....;.:0 I- ' -i --' EX2 NAVNJIE NXEC 2R1Ii EDGE UT LED EXIT SIGN CEILING MOUNTED REDSALES LETTERS ON A WHITE BACKGROUND 2 SIDED. 1 ED UNI 0 RECESSED WALL LED/ INCLUDED AREA WALL MOUNTED ► � 9 GI LEDTRF LED TRACK 'CAD WHITE 120 12.5 TRACK LED12.5PAR30/HD/DIM/ 930/NFL25 SALES AREA TRACK FIXTURE • G1 -B LEDTRF LED TRACK HEAD BLACK 120 12.5 TRACK LED12.5PAR30/HD/DIM/ 930/NFL25 WINDOW TRACK FIXTURE H (IMiiE) GSI JLAO TM232-39-SP-WH MINI THEATRICAL BELL 39 WATT METAL HAUDE TRACK HEAD WITH ELECTRONIC BALLAST SPOT. WHITE 120 39 TRACK SYLVANIA MC39T6/U/G12/830/PB H -LED ACCUUTE E3-50PS-E12-S16 SR CS 16" DIA ELONGATED 50WATT METAL HAUDE PENDANT SUSPENDED WITH AIRCRAFT CABLE ELECTRONIC BALLAST. SILVER 120 50 PEDANT MHC50/U/MP/3K-ALTO FITTING ROOM ILLUMINATION SUSPENDED AT 10'-0" 0PENDANT I I -LED ACCUU1E E3-50PS-E12-012W IMF CS 12' DIA ELONGATED 50WATT METAL HAUDE SUSPENDED WITH AIRCRAFT CAGE ELECTRONIC BALLAST. OP. WH 120 50 PEDANT MHC50/U/MP/3K-ALTO FiTTING ROOM CORRIDOR SUSPENDED AT 10'-O' DISTRIBUITON AND CONT1t)L JI TEXAS FWORESCENT BKR115EL 18' ONE LAMP 32 WATT T12 FLUORESCENT WALL -MOUNTED STRIP WITH ELECTRONIC BALLAST UNIVERSAL VOLTAGE. WHITE 120 32 WALL MOUNTED SYLVANIA (1) F15T12 TOILET ROOM MOUNTED ABOVE MIRROR BY EC J2 -LED TEXAS FWO IT IND232W-MV 48" NO LAMP 32 WATT TB FLUORESCENT INDUCTRICAL STRIP WITH REFLECTRO ELECTRONIC BALLAST UNIVERSAL VOLTAGE. WHITE 120 64 CHAIN HUNG SYLVANIAROOM (2)F032/835/ECO MNTED AATT 1122' ABOVE STOCK SHELVES CHAIN BY EC I I J3 -LED TEXAS FLUORESCENT IND332W-MV 48" THREE LAMP 32 WATT T8 FLUORESCENT INDUCTRICAL STRIP WITH REFLECTRO ELECTRONIC BALLAST UNIVERSAL VOLTAGE {ITE 120 64 SURFACE SYLVANIA (3) F032/835/ECO TAILOR CENTER I J4 -LED SIMKAR TY224-332-B11-UNV 2X4 C3) LIC�FIT PRISMATIC FIXTURE L �ATI�h OFFICE MITE 120 96 RECESSED (3) 32W 48' T8 IB•FICE J4 K MADE QTXEN11OFL EXHAUST FiN/LIGHT COMBO LOCATION TOILET ROOM VHITE 120 200 RECESSED INCLUDED TOILET RIM L� J K1 -LED GROAN QT110LE EXHAUST FAN/LIGHT COMM LOCATION+ TOILET ROOM VHITE 120 74 RECESSED INCLUDED TOILET ROOM la K2 PANASONIC FV-1IVF2 EXHAUST FAN VHITE 120 33.5 RECESSED - TOILET ROOM L PROGRESS LIGHTING P7211 -0%B LINEAR FLOURESCENT LIGHTING OVER MIRROR BRUSHED NICKEL 120 17 SURVACE Cl) 17 V T8 FL TOILET ROOM I IL 0 1I -LED JAKI E3-142CF-UN-S12-SR-CS 12' DIA PENDANT PRINTED 42V CFL LOCLOATIIN CASHVRAP SILVER 12''0 42 PEDANT CF26DT/E/INP3 D=CASHVRAP MAUVE PENDANT 11®�s M, i DP -C F2A DXL3016100 ZV SALES AREA DECORATIVE PENDANT LOCATI3* CLUB` - - IBV PENDANT S6721 18V SPIRAL LAMP El) DP -CD F23 A301121105131 -TRACK SALES AREA DECORATIVE PENDANT LOCATION• CASUAL DRESS - - 1BV PENDANT S6721 18V SPIRAL LAMP M j DP -PL POOL SL1214 SALES AREA DECORATIVE PENDANT L.I:EATI N PEEL TABLE - - - PENDANT 60040/CL 0 DP -S F2C SK12 SALES AREA DECORATIVE PENDANT LOCATIIN STUDIO - - 20-25V PENDANT 132520 0 - 25 VATT BISON STYLE LAMP ED' DP -A F2D CR-SN518GV-CG-118AR-RAL 5007 -TRACK SALES AREA DECORATIVE PENDANT LXATIOFb ACTIVE - - - PENDANT 61:G40/ii DP -DB F18 AC70-150-A21F/MED-ALUM- CS-DC(BK)24'-PERF TOP SALES ATEA DECORATIVE PENDANT =ATIEDh DENIM Bat - - 75d PENDANT 75PAR30/H/FL V Ar T2S6LED-3C-VH VATT LED Va.L VASH/FL�D WHITE 120 35 TROCK - FI IT LIC�1TIt�i AT �TVEAR 1 `yam VB T256LED-3K-WH 35 VATT LED WALL WASH/FLOOD- WHITE 120 35 'TRACK TRACK LIGHTING AT FEITTWEAR T2 T2 MO R4111 4'-0' SINGLE CIRCUIT TRACK WHITE WOE 120 0 SURFACE - ELEC1RICAL CONVEYER T4 T4 JIM) MOH 4'-0" SINGLE CIRCUIT TRACE( WHITE DUE 120 0 SWIFACE - ELECTRICAL CONVEYER T6 16 JJNO RUH 6'-0' SINGE aRC RCUIT TRACK WHITE aUE 120 0 SURFACE - ELECTRICAL CONVEYER T6 T8 TB MO RIM 8'-0' SINGLE CIRCUIT TRACK WHITE WOE 120 0 SURFACE - ELECTRICAL CONVEYER T2 -B T2 -B JIRO R4611 (-0' SINGLE CIRCUIT UIT TRACK WHITE 10.81E 120 0 SURFACE - ELECiRICAL CONVEYER T4 -B T4-8 JJNO R4SH a-0' SINGLE CIRCUIT TRACK WHITE BLACK 120 0 SIM FACE - - ELECTRICAL CONVEYER T6 -B T6 -B JJNO R6V91 6'-0" SINGLE CIRCUIT TRACK WHITE BLACK 120 0 SURFACE - ELECTRICAL CONVEYER T6 T8 -B 18-8 JI163 R8O4 8'-0' SINGE CIRCUIT TRACK WHITE BLACK 120 0 StRRFACE - ELECTRICAL CONVEYER IV / 0 THE FIXTURES WITH THE HATCHING SHALL BE ON 24 HOURS. REF. SCHEDULE THIS SHEET. STARE FOR USE ON a OMIT CAME OF FELEERPC NUT LbOiE 11434 5Kc F.IIS STI .118G4. AAPEK5, 120 W4.15 WI WF1I UPSTREAM PR>3TECTHON: MOLE I 4iCCCT OR C1:147 EST YU5T EE PROW SY MST.N.LER AS FIR STATE PAD 4004. FEM)110k$S 7YRiR1. OF kr MK= N 7 041401 FA+YL. PRAWN M rl PROTECTION Lug C MPLT NTH ALL L2C L "STATE, ,tiD NaTVCNAL. CODES: 12'D VAC CONT. PACE 2 OF 3 rte. sa47474 .) - 0 TR1 s., um 11832203747E C2 > LK I- - l ucaa 1 --- 2-112 -4--�� 0 EV MIND F;i l LJG4TR4'C (iva/im DS1114G ELLS FLOOR DORM g0_Z120/1 F3 d k5PARL SAW 1 0000 _.J L"�J U t'El U LJ L I 120V PNEL 628 T FRikT Exy SEtu n VAT (:-'0.229- - fanii I) 1IQtWLB2a $'FNASE 01. MEE 4R01T we ( /=.tv) wI) ;AN txt 365/7 1X7 Ilk a= NOTE 828 4CP, 64 STORE R1 A14D EX. SWAM ifGHr 011 SA,E PW.SE 86 co Past 015-10 !lt R OP 5117111 5£7751.5 0013011IN Aft 11314 114 OPEN 805111:11N TE0m845 A?E it -Anita nls Oc u iii 6 ThE PAx7PERTT 0.L t6T304134 .v4) (611Po. PROOLCS. uG. THE EXFLOITKRON OR TMISFtR CF AMY 16DeIYk1104 HEREIN 18 143T F101d(T1ED W THE ABSENCE CF AW AG8EDEN2 111111 CiSTA®JI8DN Ar;3 CONTROL FRCDJC15, L C AUS ANT DECRIARON MUM) 1N THIS COMM 1441 HST BE ROOM EFH2UT THE &WSW OF CISIRBUIh"N RhU CCHTRCL MOMS, U.C. 0WC MO_ DCP939 TITLE DESTINATION XL 50 UTHCENTER TUKWILA. WA 347E 11/9/13 PAGE DISTRIBUTION AND CONTROL L oF 3 PRODU8 T$. LLV ERHI NZ 2 Of 3 N A awn 05012 914424314 L C1 LEHT4G 43U4T4C1434 UNE f . -7 LW0 1 a T -o- �z T ---I--- o 113 0 I - 204E 1 " I 1321 514014 WIDOW ucKr 1' 6.4 8 reams, co 0 oowic T -STAT 00 v • N I n FWC* r. 5IGE 1 CA 3 A640 81832E314k FROM h (MITE) ci L I C CONTACTOR - LTE LA " T ROC Rti�i LES 2�L��12SA� P1rf I IMS C6LU1N AS03 01810203147L N WE) C4 ucetu1: crate= 4 INE (- 821D ! f 7323 62 1 TRICK L is G 1_201/1730 4 4 4 7777- o l 1 o -- ,$i�6 _ IpasT G curs R,co8 DX= t I 6 -°--i 1 0 --1 - - - -, _ x 1 t) L 8 9 1D _ --1- o 1120 ../7 ARE SPAT 12 -- -1- O 1 12 o--` _ -- D21,iRcKLiGFE o_(_Z4I�'13M----- 11 t4 N --t--_<r-113 o- --fi---0-1 13 0 --}E327 ----0 la 8 s SS/tii"8 LOUT 1x14 o f mLI2011.- 1 14 8 Ku ODNTLCTS AK S401 TI (PEN Pc9T1Ct4 -- - - 1 S33TE 040 40O TER* W15 ASE F€W E _ _i I- _'"` - -''AWE-SAW - 4 A34, SUNG MOM, (3c6 i2ovL O 1 11 O I f -- -� -1 - --TID41LIL - -- - -o 7777-- 1 L, Us^11W1 FABLE ts'1i1 o I--4---0 118 1 fro- 4 A40, sum OzOSE_ LIVE ----- - 1110 4SPARE, I 1 1 1 MI TOW `-7 1 1 1 _ N (WRITE) rem3 altlIoCTS IN ON Ma AS 1 N/0 i,WC 1 1 f i MRCS R4 faSSi`f10N5 5 T1,1104Q4 6 CAN 1£ t&17 QN17 AS Nig ,mr n= 42, trr ARt t27i,C f i r'1 1 ANN SONV,C15 ME WAIN IN {PEN POSITRON A ' 1-0, AA., 11 LOAD TEI#U481 S 112 11E\ 9E (ROM E SAITiCtI 1 I- ' -i --' 14. . t.3 154.'1E� Calm swam 100°1)64) . 1 LINE AND a • --mo-- u -. - • © --o---o- - ©7 _.-.-. _i. • OMIT. KEXr 030411N H (IMiiE) CENT. MOE 3 OF 3 1 N (4H1E) 8iS otrutoT 18 114E Nowt of cowl% MO CORM PRPWCTS. Etc. Tf# EXPLORATION OR TRANSFER CF A4T! 412 1L 10311 Rosati a NCA MUM/ 14 INE 0B0234M Cr Mt ginetir WT3 OSTREU11011 MO CEXTR3t. FR M13. LIC 4308 Azar 0801 1ATICN CWCCx460 14 1413 800UWnrt WT 108! IX Ci NTC40L311NF CG&JCT Of DISTRI IJTh048 AM =In 81 .4015. ttr. DWG No. Tr= DESTWATION XL DCP939 SOUTHCENTER 1 4111E =mem TUKWILA, WA DATE PA(a DISTRIBUITON AND CONT1t)L 11/9/18 2 of 3 PRODUCTS, LLC. ERHI NZ 2 Of 3 N A awn 05012 914424314 L C1 LEHT4G 43U4T4C1434 UNE f . -7 LW0 1 a T -o- �z T ---I--- o 113 0 I - 204E 1 " I 1321 514014 WIDOW ucKr 1' 6.4 8 reams, co 0 oowic T -STAT 00 v • N r0 FIII0I1 al. 618. 9Ftl. vitNEO ' 4EcEPIAUEsJ208L2 - B22. 94041 *NOM RECErTATIES120812i0 SPAS SPARE NA64 CONICS ARF Sim; 84 CPE pQ31)44 4.4E AND LOAD 1Ei 4N115 AN REVERSIBLE OMR PLATE C3 5A CB Ce 42 CJ C4 .811E I ZONE 2 236 1 1 lil iia. 1221-1 R 1357-1 146 VOLWE 511101648 MIRK CKERIC6 0 1 1 1 1 1 1 1 1 1 1 1 1 [CITING CONTROL PANEL NOTES 1. ❑ SKATES TERN• 410100( 2.0 LOCATES REIN TERIANN. PONT 3 405E COPPER INK ONLY 4. REFtACE 1R1N LASE FUSES CM 5, TORQUE TERi8HAL BLOCK"$ TO 5-7 18-14 6 SA LISTED CENTRO,. 0.1161 REASONS ROE 61 taiartlIM L1 -Li 115 COORCNt 15 THE P481)Ekr1 08 OST DN AND 6O4T1iCt 000txfcts, uG. THE DP1.O11,AT1084 OR TRANSFER Cf Atex IftfiNATION 1EA0N IS RIOT PEt8NiIFD 4Y 186 ABSENCE Cf AW 1GREETE10 41Tti 061FIRLITION 040 C0N'TROL PBCCUCTS, ILC **ANY EFCRItaki CCESTANED 3L 1685 COMMIT LAY NTN BE 80105ED 4408012 TH£ 135N5£NC' OF DIS1R6UTION AtiT OCYt1ACt PRCOLICT5. D.C. DWG 110. OCP939 iTTLB DESTINATION XL SOUTHCENTER TUKWILA, WA DATE PAGE D1s'2RIBUTION AND CONTROL 11 /D/18 3 of 3 PRODUCTS, LLC. THIS DRAWING IS FOR REFERENCE ONLY. FINAL LIGHTING CONTROLS DIAGRAM WILL BE SHIPPED WITH THE LIGHTING CONTROL PANEL. VERIFY ANY DEVIATION WITH GARY BERNSTIN AT 617-823-8620. NATIONAL ACCOUNT CONTACT: LIGHTING CONTROL PANEL AND CURRENT LIMITING PANEL GARY BERNSTEIN DISTRIBUTION AND CONTROL PRODUCTS, LLC OFFICE: 617-823-8620 FAX: 617-846-1472 REVIEWED P NFPA70-NEC DEC 18 2010 City of Tukwila DUILDfNG DIVISION RECEIVED CITY OF TUKWILA NOV 29 2018 PERMIT CENTER Project Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 Issue Date 11/09/18 Revisions Date A DeectOtion By A A A 0 cry n W 7 W U 0 (f) co co CTo V / 5K STORE 4 6 1 FROM ROAD PARAMUS, NJ 07652 9 7 3. 2 5 3. 9 3 9 3 T E L 9 7 3. 2 5 3. 9 3 9 0 F A X WWW.SARGARCH.COM El DUNHAM DUNHAM 50 South Sixth Street /Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering FOR REFERENCE ONLY Engineer's • ob Number 0419871-002 Drawn By. MMM Appv'd Br RM Sheet Title ELECTRICAL CONTROL DIAe-' ►,. Sheet Number E-3.1 # 3 4 4 4 5 6 7 8 9 1D 11 12 11 11 t4 N N r0 FIII0I1 al. 618. 9Ftl. vitNEO ' 4EcEPIAUEsJ208L2 - B22. 94041 *NOM RECErTATIES120812i0 SPAS SPARE NA64 CONICS ARF Sim; 84 CPE pQ31)44 4.4E AND LOAD 1Ei 4N115 AN REVERSIBLE OMR PLATE C3 5A CB Ce 42 CJ C4 .811E I ZONE 2 236 1 1 lil iia. 1221-1 R 1357-1 146 VOLWE 511101648 MIRK CKERIC6 0 1 1 1 1 1 1 1 1 1 1 1 1 [CITING CONTROL PANEL NOTES 1. ❑ SKATES TERN• 410100( 2.0 LOCATES REIN TERIANN. PONT 3 405E COPPER INK ONLY 4. REFtACE 1R1N LASE FUSES CM 5, TORQUE TERi8HAL BLOCK"$ TO 5-7 18-14 6 SA LISTED CENTRO,. 0.1161 REASONS ROE 61 taiartlIM L1 -Li 115 COORCNt 15 THE P481)Ekr1 08 OST DN AND 6O4T1iCt 000txfcts, uG. THE DP1.O11,AT1084 OR TRANSFER Cf Atex IftfiNATION 1EA0N IS RIOT PEt8NiIFD 4Y 186 ABSENCE Cf AW 1GREETE10 41Tti 061FIRLITION 040 C0N'TROL PBCCUCTS, ILC **ANY EFCRItaki CCESTANED 3L 1685 COMMIT LAY NTN BE 80105ED 4408012 TH£ 135N5£NC' OF DIS1R6UTION AtiT OCYt1ACt PRCOLICT5. D.C. DWG 110. OCP939 iTTLB DESTINATION XL SOUTHCENTER TUKWILA, WA DATE PAGE D1s'2RIBUTION AND CONTROL 11 /D/18 3 of 3 PRODUCTS, LLC. THIS DRAWING IS FOR REFERENCE ONLY. FINAL LIGHTING CONTROLS DIAGRAM WILL BE SHIPPED WITH THE LIGHTING CONTROL PANEL. VERIFY ANY DEVIATION WITH GARY BERNSTIN AT 617-823-8620. NATIONAL ACCOUNT CONTACT: LIGHTING CONTROL PANEL AND CURRENT LIMITING PANEL GARY BERNSTEIN DISTRIBUTION AND CONTROL PRODUCTS, LLC OFFICE: 617-823-8620 FAX: 617-846-1472 REVIEWED P NFPA70-NEC DEC 18 2010 City of Tukwila DUILDfNG DIVISION RECEIVED CITY OF TUKWILA NOV 29 2018 PERMIT CENTER Project Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 Issue Date 11/09/18 Revisions Date A DeectOtion By A A A 0 cry n W 7 W U 0 (f) co co CTo V / 5K STORE 4 6 1 FROM ROAD PARAMUS, NJ 07652 9 7 3. 2 5 3. 9 3 9 3 T E L 9 7 3. 2 5 3. 9 3 9 0 F A X WWW.SARGARCH.COM El DUNHAM DUNHAM 50 South Sixth Street /Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering FOR REFERENCE ONLY Engineer's • ob Number 0419871-002 Drawn By. MMM Appv'd Br RM Sheet Title ELECTRICAL CONTROL DIAe-' ►,. Sheet Number E-3.1 ELEC AL SYM?={. S (AU. MOLS SHORN ARE NOT NEEESSAFLY USED ON THE ORA 1,3.5 KIERUN TO PNEL 'A'. CRCUIT #1,3,5 (VHA 20A -1P CRCtRT BREAKERS). TIM #12 —41"" c0N0UCTORS POUR 9IZE), UON. A GROIMER4 COM/MICR SHALL BE PROMO GI ALL COMPS. REFER TO SPECFICATIONS FOR ADDITIONAL GROUND TS. — — — — IEL00R/UDERFI.0OR COKIIRTME --O ORW1RY MEM UP PANELBOARD - 208Y/120 VOLT, 34 4 VIRE 1 PANELBOARD - 480Y/277 VOLT, 34, 4 UK —. TELEPHONE BACKBOARD - 3/4' FIRE RATED PLYWOOD, SIZE IDICATED ON PLAN O JUNCTION BOX T SWITCH MUSED DISCCOECT SWITCH FUSED: 'AS' - INDOCATES AMPERE SIUTCH SIZE 'AF' - IDICATES MERE FUSE SZE DRY TYPE TRANSFORMER DUPLEX RECEPTACLE - 125 VOLT, 2 POLE. 3 TYPE. 20 AMPERE. MOUNTED AT 18' AFF UNLESS ODERUSE NOTED: '2' IDOCATES ORCLIT NUIRIER 'C' CDCATES MOWED 8' ABOVE COMER '54' INDICATES 54' AFF ' YHP' MUTES NATI ERPR0OF COVER 'IG' UCOCA1ES ISOLATED GROWL) TYPE 'GF` TES GROW) FAULT CROAT NITERRLFTER TWE DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 TYPE. 20 ALPEfE. 1.131111ED AT 18' AFF UNLESS ODERUSE NOTED. e- SNCLE ( RECEPTACLE, TYPE AND MOUNTING AS INDICATED ON THE DRA DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 URE, 20 MERE LOWED IN FLOOR BOX 'C' IDCATES MOWED IV CEILING CCUEICIATKR DUPLEX RECEPTACLE AND VOCE/DATA OUTLET LIGIA4TED IN FLOOR BOX ®DOME DIFLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 MIL 20 ALWERE VOWED NI FLOOR BOX. A FETE RATED POKE -MOM DEVICE ' P' IOATES DUPLEX RECEPTACLE - 125 VOLT. 2 POLE, 3 ME. 20 ALWERE 'Y MATES /DATA SBTCH - SICLE POLE TOGGLE TYPE - 120/277 VOLT. 1 -HP RATED, 20 AiWERE, MOUNTED AT 48' AFF UNLESS OTIERUSE NOTED: '3' LOCATES TREE WAY MITCH 'C' NOICATES SNITCH MOUNTED 8' ABOVE COUNTER 'o' IDEATES STITCHED FIXTURE CONTROL 'OS' IDICATES OCCUPANCY SENSOR SBTCH b' MATES DORM SWITCH - WATTAGE AS IDICATED ON PANEL SCHEDULE. EACH BRANCH CRCt11T SHALL KLUX A SEPARATE NEUTRAL CONDUCTOR 'DF' OVICATES FWORESCENT WISER SWTCH - WATTAGE AS COCKED ON PANEL SCHEDULE. EACH BRANCH CRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR 13 UGHT FIXTURE: 'A' MATES FIXTURE TYPE. '13' COICATES CRCIUT MASER, 'a a IDCATES SBTCH CONTROL.. REFER TO LUIRIAUE SCHEDIXE FOR DESCRIPTION. NL UGH1ING FIXTIARE WTH 1 BALLAST MD TO BERM= AND/OR ?MT LIGHTING CKT. 140-1 TED 'oar SIGN UGIIIVG FIXTICIE. Can MOUNTED OR WALL MOUNTED. PROM DIfECT :0AL ARROWS As TED ON FLOOR PLANS. EX DOS= FIXTURE TO REMAIN. RE EXISTING F1XTIRE TO BE RELOCATED AS Wet oR2Eisgiy ELERGEKT LDH1I4G BATTERY UNIT BTHI HEADS AS WICKED. TIE CLOCK COLEMATKIN VOCE/DATA OUTLET - MOUNTED AT 18' AFF UNLESS ODERUSE WED. PROVE( =LE GANG BOX WITH PLASTER RCN; AND 3/4' C01017 TO ABOVE TIE ASE MAG. G. 'W IES WALL MOUNTED AT 54' AFF. 'C' ROUES 8' ABOVE COUNTER. DOOR BUZZER DOOR BILL PUSHBUTTON FILE ALARM MANUAL PILL STATION MOWED AT 48' AFF. FIE ALARM AUDIO/MSUAL ALARM SIGNAL WALL MOUNTED AT 80' AFF. FRE ALARM MUM. ONLY ALARM SDNAL WALL MOUNTED AT 80' AFF. FIRE ALARM SMOKE DETECTOR FELE ALARM DUCT MOUNTED SMOKE DETECTOR - RACISM AND UCIJNIED BY LA MED BY EC EXISTING CEILING FIXTURES LEGEND ■ ■ — 1'X4'UGHT — DOWN LIGHT — 2'X2' LIGHT — TRACK LIGHT — EXIT LIGHT — EMERGENCY UGHT —MOTION DETECTOR —SPRINKLER HEAD EX = EXISTING UGHT FIXTURE TO REMAIN RE is EXISTING UGHT FIXTURE TO BE RELOCATED AS SHOWN. GENERAL ELECTRICAL TEMPORARY SERVICES A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG WITH ALL APPUCABLE INSTRUCTIONS TO BIDDERS SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. B. REQUIREMENTS FOR BIDDERS AND CONTRACTORS WHICH ARE CONTAINED IN OTHER SECTIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED BINDING UNDER THIS SECTION, UNLESS OTHERWISE NOTED HEREIN. SCOPE EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CONSTRUCTION DETAILS BEFORE SUBMITTING HIS BID. NO ALLOWANCES WILL BE MADE BECAUSE OF THE CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. INSPECTION OF SITE PROPOSALS ARE ACCEPTED WITH THE ASSUMPTION THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTILITY LOCATIONS. THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT REUEVE THE CONTRACTOR OF ANY RESPONSIBIUTY. PERMITS ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED. CODE REQUIREMENTSCOST ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS AND OWNER'S INSTRUCTIONS, AND SHALL SATISFY ALL APPUCABLE CODES, ORDINANCES, OR REGULATIONS OF THE GOVERNING BODIES. WHETHER SO SHOWN OR NOT. ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO THE OWNER. MATERIALS AND WORKMANSHIP A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS AND. UNLESS OTHERWISE SPECIFIED, SHALL BE NEW AND FREE FROM ANY DEFECTS. ALL UKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANUKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION AND. UPON COMPLETION. THE INSTALLATION SHALL BE THOROUGHLY CLEANED AND ALL DEBRIS REMOVED FROM THE SITE. CODES AND REGULATIONS EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN OR SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE WITH SUCH CODES, HE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS. ORDINANCES, RULES AND REGULATIONS AND WITHOUT GING SUCH NOTICE. THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM. PROTECTION OF WORK AND PROPERTY A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK. HE SHALL MAKE GOOD ANY SUCH DAMAGE. INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT TO HIS FAULT OR NEGUGENCE. HE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THEIR EMPLOYEES ON THE JOB AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF, OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBUC LIABILITY. CHANGES IN THE WORK THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING. ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY. COOPERATION ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPUSHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE ADEQUATE TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. THE OWNER SHALL BE CONSULTED TO RESOLVE ANY QUESTIONS WHICH MIGHT ARISE BETWEEN TRADES AS TO THE PLACING OF UNES. DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO REMOVE ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OF STRENGTH OF THE STRUCTURE. SUBSTITUTION OF MATERIALS MANUFACTURER'S NAMES ARE USTED HEREIN TO ESTABUSH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF THE TENANT. THE SUBSTITUTE MATERIAL IS OF A QUALITY AS GOOD OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL AND .DEPENBILITY. THE PURPOSE FOR WHICH THE ITEMS EFFICIENCYDA SPECIFIED WERE INTENDED. SHOP DRAWINGS SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND SUCH OTHER ILLUSTRATIVE MATERIAL AS MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THE CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND CHANGES DURING CONSTRUCTION. DRAWINGS AND SPECIFICATIONS A. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS UNES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL OR ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. B. SHOULD THE CONTRACTOR DEEM IT NECESSARY TO MAKE CHANGES TO ITEMS SHOWN ON CONTRACT DRAWINGS. THE SHOP DRAWINGS. DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. RESPONSIBILITY THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE FINISHED OPERATING SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK. REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. DEMOUTION WHERE ELECTRICAL WORK TO REMAIN IS DAMAGED OR DISTURBED IN THE COURSE OF THE WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY. QUALITY. AND FUNCTIONALITY. A. ACCESSIBLE WORK INDICATED TO BE DEMOUSHED: REMOVE EXPOSED ELECTRICAL INSTALLATION IN ITS ENTIRELY. B. ABANDONED WORK: CUT AND REMOVE BURIED RACEWAY AND WIRING INDICATED TO BE ABANDONED IN PLACE 2 INCHES BELOW THE SURFACE OF ADJACENT CONSTRUCTION. CAP AND PATCH SURFACE TO MATCH EXISTING FINISH. C. REMOVAL: REMOVE DEMOUSHED MATERIAL FROM THE PROJECT SITE. D. TEMPORARY DISCONNECTION: REMOVE, STORE, CLEAN, REINSTALL, RECONNECT, AND MAKE OPERATIONAL COMPONENTS INDICATED FOR RELOCATION. GENERAL EALLLE WIRING SHALL MINIMALLY CONFORM TO THE STANDARDS OF THE NATIONAL �CTR � CODE AND MEET ALL. LOCAL REGULATIONS. UGHTING AND POWER PANELS 1. ALL UGHT AND POWER PANELS SHALL BE GENERAL ELECTRIC. CUTLER—HAMMER, SQUARE D OR I—T—E UTIUZING BOLTED BREAKERS WITH INTEGRAL MAIN BREAKER SIZE PER PLANS. STEP DOWN TRANSFORMERS 1. STEP DOWN TRANSFORMERS SHALL BE EQUAL TO GE OR SQUARE D 600 VOLT CLASS, "DRY TYPE', SINGLE OR THREE PHASE PER PLANS, CLASS 'R' INSULATION WITH MULTIPLE TAPS ABOVE AND BELOW RATED VOLTAGE. CONDUIT 1. ALL CONDUIT SHALL BE RUN CONCEALED IN FINISHED AREAS. ALL CONDUIT UNDER GROUND OR IN CONCRETE SLAB SHALL BE RIGID CONDUIT. ALL OTHER CONDUIT MAY BE 'THIN WALL". ALL OUTLETS SHALL BE FLUSH MOUNTED. ALL CONDUITS SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLESpOY TO THE BUILDING CONSTRUCTION AND SHALL BE LEVEL. 2. CONTRACTOR WILL PROVIDE NECESSARY CABLES, JUMPERS, ETC. TO INSURE GROUND IN CONDUIT SYSTEM. 3. E.C.R. S REQUIRE TRUE THREE WIRE DEDICATED AC UNES. THIS ISA TRUE GROUND NOT A NEUTRAL CONDUIT MUST NOT BE USED AS THE ONLY GROUNDING MEANS. 4. ALL WIRING CONDUITS, ETC. REQUIRED FOR THE PROPER CONTROL OF THE HVAC SYSTEMS SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL SUB— CONTRACTOR. THE MECHANICAL SUB—CONTRACTOR SHALL SUPPLY THE CONTROLS AND WIRING DIAGRAMS TO THE ELECTRICAL SUB—CONTRACTOR. ALL UNITS SHALL BE PROVIDED WITH INDMDUAL DISCONNECTS AT EACH UNIT IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. 5. WHERE STORE IS ON ANY LEVEL BUT GROUND LEVEL. THE TENANT'S GENERAL CONTRACTOR SHALL RUN ALL CONDUIT FOR ELECTRICAL FLOOR OUTLETS AND TELEPHONE FLOOR OUTLETS TIGHT AGAINST THE UNDERSIDE OF THE SECOND FLOOR LEVEL THE SECOND FLOOR STRUCTURAL SLAB SHALL BE CORED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS SHOWN ON THE PLANS. 6. ALL TELEPHONE WIRE SHALL BE INSTALLED IN CONDUIT. ALL WIRE SHALL BE COPPER. CONDUCTORS 1. NO ALUMINUM WIRING IS ACCEPTABLE. 2. NO. 10 AND SMALLER, SOUD CONDUCTOR, COPPER TYPES. TW. TNR. THWN. R, RH, RHW. WITH IDEAL WINGNUTS AND SCOTCHLOCK CONNECTORS. 3. NO. 8 AND LARGER, STRANDED CONDUCTOR, COPPER TYPES, THW, THWN, RHW, WITH SOLDERLESS BOLTED PRESSURE CONNECTORS. 4. FIXTURE WIRING. WIRING IN CHANNELS OF FLUORESCENT FIXTURES SHALL BE EITHER RHH ON THERMOPLASTIC 'APPLIANCE WIRE' - 105 DEGREE C COPPER (CSA TYPE THW). 5. MINIMUM SIZE, SHALL BE NO. 12 AWG. TYPE THWN. EXCEPT FOR CONTROL CIRCUITS. OUTLET BOXES FLOOR OUTLETS SHALL BE HUBBELL DUPLEX FLUSH RECEPTACLE 15A 125V, MODEL (5262—WHY (WHITE), RECESSED IN FLOOR BOX HUBBELL #B2436 SQUARE AND ROUND COVER (BRASS) WITH DUPLEX FLAPS, HUBBELL #S-3825. EACH FLOOR BOX SHALL BE SUPPLIED WITH THE APPROPRIATE HUBBELL SERIES 5-3084 CARPET FLANGE TO ACCOMMODATE THE VICINITY FLOORING. WALL OUTLETS AND OUTLET COVERS SHALL BE GRAY IN COLOR. BUZZERS/CHIMES/PUSH BUTTONS 1. BUZZERS. CHIMES AND PUSHBUTTONS SHALL BE EQUAL TO THOSE MANUFACTURED BY EDWARDS AND SHALL OPERATE FROM A 24 VOLT TRANSFORMER ON THE STOCKROOM RECEPTACLE CIRCUIT. 2. WHEN USED IN AN EXTERIOR CONDITION, THE PUSH BUTTON SHALL MEET NEMA STANDARDS FOR EXTERIOR OPERATION. 3. CHIMES AND BUZZERS SHALL BE MOUNTED ON THE WALL. (BENEATH THE CEIUNG) IN THE STOCKROOM AND INSIDE THE CASH/WRAP IN THE SALES AREA. 4. SIGNAL CONDUCTORS WIRING FOR ANNUNCIATOR DEVICES AND BETWEEN MULTIPLE DEVICES AND THEIR ACTIVATORS. SHALL BE ROUTED AND SHIELDED ACCORDING TO PREVAILING ORDINANCES. EQUIPMENT IDENTIFICATION 1. IDENTIFY ALL EQUIPMENT AND APPARATUS WITH ENGRAVED BAKELITE NAMEPLATE OR IMPRESSED, PLASTIC NAME STRIP. 2. FURNISH A TYPEWRITTEN CIRCUIT DIRECTORY CARD IN ALL LIGHTING AND POWER PANELS. THECONTRACTOR SHALL PROVIDE THE FOLLOWING SPECIFIC ITEMS OF TEMPORARY SERVICES: TELEPHONE — THE TENANT'S GENERAL CONTRACTOR SHALL INSTAL_ A JOB SITE TELEPHONE AND NOTIFY TENANT AS USTED ON SHEET A-1 OF THE TELEPHONE NUMBER AND THE NAME OF THE SUPERINTENDENT. TEMPORARY WATER — WATER REQUIRED IN THE PERFORMANCE OF THE CONTRACT SHALL BE PROVIDED AND PAID FOR BY THE CONTRACTOR. WATER USED FOR HUMAN CONSUMPTION SHALL CONFORM TO REQUIREMENTS OF STATE AND LOCAL AUTH0 RHES FOR POTABLE WATER. TEMPORARY ELECTRICITY — TEMPORARY ELECTRIC SERVICE REQUIRED IN THE 1 PERFORMANCE OF THE CONTRACT SHALL BE FURNISHED AND PAID FOR BY THE CONTRACTOR WHO SHALL FURNISH, INSTALL, AND MAINTAIN ALL TEMPORARY OVERHEAD CONSTRUCTION. METERS. DROPS. AND OTHER WIRING AND FITTINGS FOR BOTH UGHT AND POWER AT LOCATIONS REQUIRED IN THE WORK AND SHALL BEAR THE COST OF MAKING THE SERVICE CONNECTIONS. BEFORE FINAL ACCEPTANCE, TEMPORARY ELECTRICAL SERVICE FACILITIES INSTALLED BY THE CONTRACTOR SHALL BE REMOVED, AND THE SERVICE CONNECTIONS SEVERED IN ACCEPTABLE MANNER. HEAT — WHEN REQUIRED FOR PROPER INSTALLATION OR PROTECTION OF ANY PORTION OF TTEMPORARY HEATINGHE WORK, THE UNITSCONTRACTOR SHALL FURNISH AND INSTALL AS APPROVED BY THE LANDLORD OR LOCAL AUTHORITY.CONTINUOUS OF LANDLORD PROVIDED UTILITY SERVICES — IF THE LANDLORD ELECTS TO PROVIDE TEMPORARY UTILITY SERVICES. THE CONTRACTOR WILL BE SO INFORMED BY THE TENANT. THE CONTRACTOR SHALL MAKE PROVISIONS OR COORDINATE WITH LANDLORD'S GENERAL CONSTRUCTOR TO PAY THE COST OF SAID TEMPORARY CONSTRUCTION AND UTILITY SERVICES. NOTE FOR TENANT GENERAL CONTRACTOR: IT IS THE RESPONSIBILITY OF THE TENANTS GENERAL CONTRACTOR TO MAKE USE OF APPUCABLE NOTES & SPECIFICATIONS USTED ON THIS SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. REFERENCE OTHER MEP SHEETS FOR AND/OR OVERRIDING SPECIFICATIONS. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THE SUB—CONTRACTOR WITHOUT ADDITIONAL CHARGE TO THE TENANT. COMMPLIANCE POR NFPA 0 -NEC DEC 1 8 2018 City of Tukwila @UNLDING DIVISION RECEIVED CITY OF TUKWILA Nov 29 2018 PERMIT CENTER Prat Address DXL# 9843 SOUTHCENTER 17401 SOUTHCENTER PKWY TUKWILA, WA 98188 Issue Date 11/09/18 Revisions Date Desattion By a 0 n ry 7 U Z (0 ( ) \--C3 00 00 076 O� Q 5K STORE 4 6 1 FROM ROAD PARAMUS, Ni 07652 973.253.9393 TEL 973.253.9390 F A X WWW.SARGARCH.COM 1 DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering Engineer's Job Number 0419871-002 Drawn By. MMM Appy d By. RM Sheet Title ELECTRICAL SPECS AND QETALE Sheet Number E-4.0