Loading...
HomeMy WebLinkAboutPermit EL18-1092 - STERLING SOUTHCENTER- SOLAR - INSTALL SOLAR SYSTEM ON ROOFTOP, CONNECT TO HOUSE AND MAIN ELECTRICAL ROOMSTERLING SOUTHCENTER - SOLAR 407 BAKER BLVD ELI 8-1092 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223100087 407 BAKER BLVD ELECTRICAL PERMIT Project Name: STERLING SOUTHCENTER- SOLAR Permit Number: Issue Date: Permit Expires On: EL18-1092 6/10/2019 12/7/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: PEARL ALVIN+CARLE 9741 E ESTANCIA WAY , SCOTTSDALE, WA, 85262 ELLA WILLARD-SCHMOE 805 RAINIER AVE S , SEATTLE, WA, 98188 PUGET SOUND SOLAR LLC 5308 BAKER AVE NW , SEATTLE, WA, 98107 PUGETSS920RH Phone: (206) 661-7601 Phone: (206) 706-1931 Expiration Date: 12/8/2020 DESCRIPTION OF WORK: INSTALLATION OF 29 K W DC (23 KW AC) SOLAR SYSTEM ON BUILDING ROOFTOP, CONNECTED TO A HOUSE PANEL IN LEVEL 1 MAIN ELECTRICAL ROOM. Valuation of single family: $0.00 Valuation of mf/comm: $19,078.00 Type of Work: TENANT IMP Fees Collected: $609.46 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: );_ 2017 2017 2017 2015 Date: 6;° 101 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: C ) `I This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: *"ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httplANww.TtikwilaWA.gov Electrical Permit No. t/I(P UTZ,. Project No. Date Application Accepted: Date Application Expires: le6 161 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: tkol 4//Baker Boulevard Tenant Name: N/A - new bldg under construction King Co Assessor's Tax No.: 022310-0080 Suite Number: Floor: New Tenant: 0 Yes 0..No PROPERTY OWNER Name: Ella Willard-Schmoe Name: Alliance Residential Company City: Seattle State: WA Zip: 98144 Address: 1325 4th Ave, STE 1005 Email: ewillard@pugetsoundsolar.com City: Seattle State: WA Zip: 98101 CONTACT PERSON — person receiving all project communication Name: Ella Willard-Schmoe Address: 805 Rainier Ave S City: Seattle State: WA Zip: 98144 Phone: (206) 661-7601 Fax: Email: ewillard@pugetsoundsolar.com ELECTRICAL CONTRACTOR INFORMATION Company Name: Puget Sound Solar Address: 5308 Baker Ave NW City: Seattle State: WA Zip: 98107 Phone: (206) 706-1931 Fax: Contr Reg No.: pugetss920rh Exp Date: 12/08/2020 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ I 01 46 Scope of Work (please provide detailed information): Installation of 29 kW DC (23 kW AC) solar PV system on building rooftop, connected to a house panel in Level 1 main electrical room. Will service be altered? p Yes 0 No Adding more than 50 amps? El Yes J No Not a load Type of Use: Type of work: ▪ New 0 Addition 13 Service Change 0 Remodel Tenant Improvement O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: [ZI Puget Sound Energy Seattle City Light W:\Permit Center \ Applicatione-HandoutaTermit Applications \ PDFsTlectrical Permit Application Revived I-1-17.docx Revived: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings O Low voltage systems (alarm, furnace thermostat) $155.91 S83.54 ea 561.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 583.54 (no addedlaltered circuits) O Service change with added/altered circuits 583.54 number of added circuits 512.00 ea ❑ Circuits added/altered without service change 555.69 (up to 5 circuits) ❑ Circuits added/altered without service change 555.69 (6 or more circuits) 57.65 ea ❑ Meter/mast repair 569.62 ❑ Low voltage systems 561.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 566.30 ❑ Temporary service (generator) 582.52 ❑ Manufactured/mobile home service 587.98 (excluding garage or outbuilding) ❑ Carnivals 582.21 Number of concessions 51 L02 ea Each ride and generator truck 511.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 12/19/2018 Print Name: Ella Willard-Schmoe Day Telephone: (206) 661-7601 Mailing Address: 805 Rainier Ave S Seattle WA 98144 W:lPennit CentecWpplicationa-Hmideute\ Revised: January 2017 bh it Applications\PDFa.Electrical Permit Application Revised 1-1-17.docx City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $72.10 EL18-1092 Address: 407 BAKER BLVD Apn: 0223100087 $72.10 Credit Card Fee $2.10 Credit Card Fee R000.369.908.00.00 0.00 $2.10 ELECTRICAL $70.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R18567 R000.345.830.00.00 0.00 $70.00 $72.10 Date Paid: Friday, September 13, 2019 Paid By: JACOB HANSON Pay Method: CREDIT CARD 013967 Printed: Friday, September 13, 2019 12:44 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R17848 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $495.03 EL18-1092 Address: 407 BAKER BLVD Apn: 0223100087 $495.03 Credit Card Fee $14.42 Credit Card Fee R000.369.908.00.00 0.00 $14.42 ELECTRICAL $457.72 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $457.72 TECHNOLOGY FEE $22.89 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17848 R000.322.900.04.00 0.00 $22.89 $495.03 Date Paid: Monday, June 10, 2019 Paid By: ELLA WILLARD-SCHMOE Pay Method: CREDIT CARD 010441 Printed: Monday, June 10, 2019 3:49 PM 1 of 1 c SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $857.67 D18-0391 Address: 407 BAKER BLVD Apn: 0223100087 $743.24 DEVELOPMENT $743.24 PLAN CHECK FEE R000.345.830.00.00 0.00 $743.24 EL18-1092 Address: 407 BAKER BLVD Apn: 0223100087 $114.43 ELECTRICAL $114.43 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R16166 R000.345.832.00.00 0.00 $114.43 $857.67 Date Paid: Wednesday, December 19, 2018 Paid By: ELLA RENEE WILLARD SCHMOE Pay Method: CHECK 306 Printed: Wednesday, December 19, 2018 11:25 1 of 1 AM SYSTEMS c o CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/13/2019 VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: X 12:44:22 PM CREDIT CARD SALE **********3571 K $72.10 013967 000 kandace {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 06/10/2019 03:47:43 PM CREDIT CARD SALE VISA CARD NUMBER: **********2002 K TRAN AMOUNT: $495.03 APPROVAL CD: 010441 RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: 640._Address: Date Called: Special Instruc ons: Date Wanted: Co(CI a.m. p.m. Requester: ,�e Phone No: 6 yp2_ 61f c. 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P.v\- Inspector: Date: n REINSPECTION EE REQUIRED. Prior to next inspection, fee 7 st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. HYUNDAI SOLAR MODULE RI SERIES Cells PE PERL technology provides ultra-hig efficiency with better performance in low irradiation. Maximizes installation capacity in limited space. Multi -Crystalline Type HIS-M310RI HIS-M315RI Mono -Crystalline Type HIS-S330RI HIS-S335RI HIS-S350R1 HiS-S355RI AUG 07 2019 iShoolf Tukwila Buitsnrc DIVISION HiS-M320R1 HIS-S340RI HIS-S345RI HiS-S360RI {JADE IN KOREA Power Ger eration In Low Light Hyundai Cell. Made in Korea HYUNDAI Reliable Warranty Global brand with powerful financial strength provide reliable 25 -year warranty. Hyundai's Warranty Provisions • 10 -Year Product Warranty • On mater"als and workmanship • 25 -Year Performance Warranty • 90% of guaranteed min. power for 1C years • 80% of guaranteed mn. power for 25 years Certification www.hhigreen,corn Low LID / PID o h LID(Light Induced Degradation) and PID(Potential Induced Degradation) are strictly eliminated to ensure higher actual yield during lifetime. A01 Corrosion Resistant A.A.A.P. OkAA.110.0. Various tests under harsh environmental conditions such as ammonia and salt -mist passed. About Hyundai Solar t t t Mechanical Strength Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow and strong wind. UL 1 VDE Test labs Hyundai's R&D center is an accredited test laboratory of both a and vriECEIIIED CITY OF TUKWILA JUL 30 n19 FILE Established r 1972, Hyundai Heavy Industres (I -4H) is one a the rnost trustplIVIrmENTER industries sector veh 48.000 employees and more than 40 BilVor USD r arru.r. a global leader and ;rnovator, Hyundai Heavy Iriclustres is committed to budding a future growth enTrie by develop!rig ard rvestirig heasily r he feld of renewable energy. Started as a core busness divIsion of HH, Hyundai Solar (Hyundai Heavy Industries Green Errergy) new stands as or independent company and an affirate of HH I as from December 2016. It ;s the largest and the longest standing PV cell and module manufacturer in South Korea with 800 MW of module production capac;ty. We have strong fide to proving !-Cgh-guaIity solar PV products to more than 3,000 customers worldwide. REVISION NO. _L tvotia„, EL19-101 Priritol airo€ ' 0512017 Electrical Characteristics Nominal Output in mpp I Open Circuit Voltage I V:1! Short Circuit Current )Ix;) Voltage at Pmax ('vnii,l)I Current at Pmax i intppt Module Efficiency Cell Type Maximum System Voltage Temperature coefficient of Pmax Temperature coefficient of Voc Temperature coefficient of Isc Multi -Crystalline M ,,HIS -M._. -RI) ule Mono -Crystalline Module (HiS-S__RI) 310 45.3 8.9 36.0 8.6 15.8 315 45.3 9.0 36.2 8.7 16.1 320 45.5 9.0 36.4 8.8 16.4 6", multi -crystalline silicon 1,000 -0.4 l -0.31 0.039 330 46.3 9.3 38.0 8.7 16.9 335 46.5 9.4 382 8.8 17.1 340 345 350 46.7 46.9 47.1 9.5 9.6 9.6 38.4 38.6 38.7 8.9 9.0 9.0 17.4 17.6 17.9 6", mono -crystalline silicon 1,000 -0.40 -0.29 0.039 355 47.3 9.7 38.9 9.1 18.1 360 47.4 9.8 39.1 9.2 18.4 Mechanical Characteristics Dimensions Weight Solar Cells Output Cables Junction Box Bypass Diodes Construction Frame •N data at STC atandard Teat Can6Sme). Powe data mai be chanced without prior notice. 998 mm (39.29)(W) x 1,960 mm (77.17)(L) x 40 mm (1.57)(H) Approx. 22.9 kg (50.5 lbs) 72 cells in series (6 x 12 matrix) (Hyundai cell, Made in Korea) 4 mm2 (12AWG) cables with polarized weatherproof connectors, EC certified (UL listed and UL 4703 certified), Length 1.2 m (47.2) IP67, weatherproof, EC certified (UL listed) 3 bypass diodes to prevent power decrease by partial shade Front :Anti -reflection coated glass, 3.2 mm (0.1261 Encapsulant : EVA I Bad( Sheet :Weatherproof film Clear anodized aluminum alloy type 6063 Module Diagram ru Mono -Crystalline Mul i -Crystalline Si Type -front Side View Si Type Front Side View D DETAL A 4-e] SLOT T1e111 /tinted ori I 5C certiAtid PSC DETAIL S SECTION CC A 35 1 SECTION D-0 DETAIL E Sales & Marketing 55, Bundang-ro. Bundanggu, Seongnam-sl, Gyeonggi-do, 13591, Korea Ter +82-31-8006-6910.6930.6906 1 Fax: +82-2-746-7675 'ung Installation Safety Guide • Only qualified personnel should install or perform maintenance. • Be aware of dangerous high DC voltage. • Do not damage or scratch the rear surface of the module. • Do rot handle or install modules when they are wet. Nominal Operating Cell Temperature Operating Temperature Maximum System Voltage Maximum Reverse Current I-V Curves Current [A] 46°C t 2 -40 - 85"C DC 1,000V(IEC) DC 1,000 V (UL) 15A Uu to 350W) 20A IAnove 355W) Current [A] a _.. ion brad=1.000W/nf B ` ince. kat = aatNItgf 5 4 30 40 50 Voltage [ V Gateau - Sod. kcal= Blaiedd Bad Old 42324V Pm' 7 1 • .._ Kat kra1 = N Stirtn' ° 0 s 1° 15 Al 25 30 35 w a 50 Vuhage[V 1 HYUNDAI GREEN ENERGY Printed Date DS2C17 . 4, proharvest Inverter Series byOutBackPower 208V & 480V MODELS Features • Rugged three-phase (208V and 480V) plug -and -play systems • Small and light (hand-holdable, 241bs) • Non -isolated inverter for use with ungrounded DC systems • 200-850V MPP voltage range for 600V and 1000V systems • Two DC string inputs with independent monitoring and Maximum Power Point Tracking (MPPT) • Waterproof NEMA6, silent convection cooling • Designed for high reliability, uses no electrolyic capadtors • Wide temperature range (-40 to 65°() • Utility -interactive, listed to UL1741 • Compliant with NEC 690.11 arc detection Applications • Rooftop commercial: usable where other solutions just won't work such as coastal, desert and high altitude locations • Car ports, parking and shade structures: can be mounted at any orientation, under modules, on racking without extra strengthening (dear of risk of liability from vandalism) OutBack reserves the right to make changes to the products and infomation contained in this document without notice, Copyright 0 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group www.outbackpowar.com A Inverter Series SPECIFICATIONS OC input (2 Identical Inputs) ax. Open Circuit Voltage (per string) Full Power MPPF Range (per string) PV Start Voltage DC Aliowabie Stadting Ratio (total, 2 inputs combined). DC Maximum Input DC Disconnect Means PR0208.5k75 1(AlOVDC 325 to 525VDC 200VDC Must not exceed a9 under any rieumstances (orient Ise DC Wynn. 106 Short daft curre nt: 30A Sourer back feed current to Input source:OA PR0480-8k 1000VDC 425to850VDC /00VDC Must not exceed 6375 under any circumstances (nrent (per DC input): 10A Short arson current: 30A Source back feed anew to Input sorrce:OA O,'z()! 1 DC. connector has been evaluated and approved for use as the load -break disconnect required by the EC (NEC section 690.17, allowed by the exception of meeting requirements specified in 690.33) '0n the DC side of the inverter, each input limits at 365 inverter limes arc as described above. AC Output AC Maximum AC Derate (40-65°C) AC Nominal Output Current (per phase) AC Three -Phase System Compatibility AC Voltage Range (limits adjustable) AC Output Frequency Range (limits adjustable) Power Factor AC Lower Trip Umit AC Upper Trip Limit AC Reconnect Delay AC Synchronization In -Rush Current Maximum Output Fault Current and Duration AC Minimum Wire Gauge (for grid connection) AC Disconnect Means nd/or 10A (2086 model) or SkW and/or 106 (480V model(, and the combined total AC output is lir PR0208-5 k75 Continuous total output power Ito 45°C).5,750W Continuous output current (per phase): 16A Output (Nerarrent protection: 606 -102W per °C 16A 208V Wye, three phases, neutral and ground Phase to Phase Minimum:183V Nominal:2086 Maximum: 229V Phase to Neutral Minimum 1069 Nominal 1209 Maximum:132V Minimum:593Hz Nominal:60Hz Maximum:60.5Hz _0.98 Frequency Default (t1Hz(:59.3Hz Adjustment I±tHz):57to 59.311z Clearig Time Default (i2 Cydes): 016s Oeadng Time Mjust men 13 2 CPies): 0.16 to 300s Frequency Default I±1Hz): 60.5Hz Adjustment (11 Hz):60.5 to 62.0Hz Clearing Thne Default (12 Cycles): 0 16s OearingThee Adjustment (. 2 (ydnt 0.161300s Defardt: 5mm Adjustment 1 s to 16min oA 16A, <0.5ms 12 AWG Voltage (Phase to Nieman Default (1.2%(:106V Adjustment (±296): 85 10 1066 Clearing Time Default 112 Cycles): 2s Clearing Mee Adjustmert(i2 Cycles). 1 to 20, Voltage IPhasc to Neutral) Default (±7%1:1329 Adjustment (_2%(:132 to 144V Clearing Thne Default (12 Cycles): 1 s Clearing Tone Allurement( -t2 eydesk I to 20s .7 (208V mock!) a 8kW (480V model). Higher DC STC string powers maybe applied, the PR0480-8k Continuous total output power (to 45"C): 81tW Conti nwus output anent (per phase): 9.6A Output overanent protection: 60A -150W per °C 9.6A 4'rr V Wye, three phases, neutral and ground Phase to Phase Minimum:422V Nominal:48w Maximum: 5286 Phase to Neutral Minimum: 244V Nominal: 277V Maximum: 365V Minimum: 59311z Nominal:60Hz Maximum: 60.5 Hz 20.98 Frequency Default (±1Hz):59.3Hz Adjustment (11 Hz): 57 to 59.3 Hz Gearing Time Default 112 Cycles): 0:16s OeaHn9Tene Mjustmen(_+.2 (ydesk0.1610300, Frequency Defadt( 1Hz1:6115Hz Adjustment (i 1 Hz(:60.5 to 62.0Hz Gearing Time Default (±2 Cycles): 0.16s oearingTImeAdjustment (r:2 ( ydes): 0,18 to 300, Default:5min Adjustment: l s to lOmin 00 10A, <O3ms 14 AWG Voltage (Phase to Neutral) Default (±2%):245V Adjustment (12%1:220 to 245V Clearing Tlme Default 112 Cycles): 2s Clearing ilme Adjunman (t2 Cycles): 1 to 26s Voltage (Phase to Neutral) Default (±2961: 3050 Adjustment (±±296): 305 to 3150 Dearing Time Default 112 Cycles(: l s Clearing Time Adjustment I! 2 Cydes1 l to 20s The AC Connecta has been evaluated and approved for use as the load -break disconnect required by the NEC MEC section 690.17, allowed by the exception of meeting requirements specified in 690.33) 0ther Specification Dimensions N x W x D (mm/in ) Weight (kg/Ib) Operating Temperature Range (°C/°F) Power Consumption Cooling Communication Environmental Rating Certifications Warranty PR0208-5k75 P 475x334x76/18.75x13.125x3 11/24 -400n65/-401o150 Standby: <4.SW Night: <4.SW Natural convection, no fan Powerline Outdoor/rooftop, NEMA 6,1P67 PR0480-8k 475x33407 11/24 -40to65/'lOtol50 Standby. <4.5W Night: <4.5W Natural conxcction, no fan Powerline Outdoor/rooftop, NEMA 6,1P67 Listed to U1.1741/IEEE 1547 (utility rntera tivel CSA C222 No.107.1, FCC Part 15, mean the requven nos of NEC 690.11 layer, optionally extendable 10 -year, optionally extendable OulBack reserves the right to make changes to the products and information contained in this document without notice. Copyright © 2017 OutBack Power. All Rights Reserved. OutBack is a registered trademark of The Alpha Group. www.outbackpower.com Daft& svit-co - www.hhi-green.com/solar/en Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company. The company employs more than 48,000 people, and has a global` leading 7 business divisions with sales of 40.9 Billion USD in 2015. As one of our core businesses of the company, Hyundai Heavy Industries is committed to develop and invest heavily in the field of renewable energy. Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea. We have 800 MW of module production capacity and provide high-quality solar PV products to more than 3,000 customers worldwide. We strive to achieve one of the most efficient PV modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies. RI -Series Poly -crystalline Type HIS-M310RI 1 HIS-M315RI 1 HIS-M320RI I HiS-M325RI Mono -crystalline Type HIS-S330R1 I HiS-S335RI 1 HiS-S340RI 1 HiS-S345RI HIS-5350RI 1 HiS-S355RI 998 mm (39.29")(W) x 1,960 mm (77.17")(L) x 40 mm (1.57")(H) Approx. 22.9 kg (50.5 lbs) 72 cells in series (6 x 12 matrix) (Hyundai cell, Made in Korea) 4 mm2 (12AWG) cables with polarized weatherproof connectors, IEC certified (UL listed and UL 4703 certified), Length 12 m (47.2") 1P67, weatherproof, IEC certified (UL listed) 3 bypass diodes to prevent power decrease by partial shade Front : Anti -reflection coated glass (Anti reflection coated), 32 mm (0.126") Encapsulant : EVA Back Sheet :Weatherproof film Clear anodized al • IEC 61215 (Ed.2) and IEC 61730 by VDE • UL listed (UL 1703), Type 1 for Class A Fire • Output power tolerance +3/-0% • 150 9001:2000 and 150 14001:2004 Certifie • OHSAS 18001:2007 Certified • Advanced Mechanical Test (5,400 Pa) Passe / Mechanical Load Test (40 Ibs/fV) Passed (UL) • IEC 62716 (Ammonia Corrosion Resistance Test) Passed • IEC 61701 (Salt Mist Corrosion Test) Passed • Potential -Induced Degradation (PID) Test Passed (85'C / 85 % / 600 hr-PVEL) X Several models are under certification process. • VDE (Test Data Acceptance Program) • UL (Witness Test Data Program) • 10 years for product defect • 10 years for 90 % of warranted min. power • 25 years for 80 % of warranted min. power s Important Notice on Warranty The warranties apply only to the PV modules with Hyundai Heavy Industries Co., Ltd.'s RECEIVE).....::: logo (shown below) and product serial number on it. CITY OF /"U K B ILA DEC 19 2018 '•}4' � � �� � CENTER €11 1E1 41Wfa ‚.PERMIT HYUNDAI HEAVY INDUSTRIES 1 Poly -crystalline Type 1 Nominal output (Pmpp) Voltage at Pmax (Vmpp) Current at Pmax (Impp) Open circuit voltage (Voc) Short circuit current (Isc) Output tolerance No. of cells & connections Cell type Module efficiency Temperature coefficient of Pmpp Temperature coefficient of Voc Temperature coefficient of Isc V A V A pcs %/K %/K %/K 310 36.0 8.6 45.3 8.9 315 36.2 8.7 455 9.0 320 36A 8.8 45.7 9.0 +3/-0 72 in series 6" Poly -crystalline silicon (Hyundai cell, Made in Korea) 15.8 16.1 16.4 -0.41 -032 0.039 3t All data at STC (Standard Test Conditions). Above data may be changed without prior notice. 1 Mono -crystalline Type 1 Nominal output (Pmpp) W 330 335 340 345 350 Voltage at Pmax (Vmpp) V 38.0 382 38.4 38.6 38.7 A 8.7 8.8 8.9 9.0 9.0 V 463 465 46.7 46.9 47.1 A 9.3 9A 9.5 9.6 9.6 % +31-0 No. of cells & connections pcs 72 in series Cell type - 6"Mono-crystalline silicon (Hyundai cell, Made in Korea) Module efficiency % 169 17.1 17.4 17.6 17.9 Temperature coefficient of Pmpp %/K -0.42 Temperature coefficient of Voc %/K -030 Temperature coefficient of Isc %/K 0.047 0 All data at STC (Standard Test Conditions) Above data may be changed without prior notice. Current at Pmax (Impp) Open circuit voltage (Voc) Short circuit current (Isc) Output tolerance 1 Module Diagram 1 11111111111111111111111111 1111111111111111111111111 11111111111111111111111 III 111111111111111111111111111 1111111111111111111 111 III 1111111111111111111 111 III 11111111111111111111111 III 1111111111111111111111 111 11111111111111111 111 111 111111111111 111 1111 111 11111111111111111111 III IIIIIIn1E 11111111 I1;1 99809.29 A 1. MOUND MARK 40042 GROUND HOLE 94807327 l4 X07211 HOLES 1252(9.97! ri 1 Installation Safety Guide 1 • Only qualified personnel should install or perform maintenance. • Be aware of dangerous high DC voltage. • Do not damage or scratch the rear surface of the module. • Do not handle or install modules when they are wet. 40; \ f+lnted or FOC certtiei FSC (unit: mm, inch) 1 IN Curves 1 6.510167 DETM.A 41_ 8-07 SLOTTOBiU .� 803 DETN4.B Sales & Marketing Hyundai Bldg., 75, Yulgok-ro, Jongno-gu, Seoul 03058, Korea Tel : +82-2-746-7563, 7635, 8406 Fax : +82-2-746-7675 0•3448[41 19 325 36.6 8.8 45.9 9.1 16.6 355 38.9 9.1 473 9.6 18.1 Mud.had =1,000W/nr Opea849CeBTemp=ST - Operating [diem =i5'C Clpeeatilg CeBTenp =45C Opeatilg CdTaep=65'C anent LAI z !mid. hod=IAOOWhre Ycd.kad.800W/m, 4-Incd.kad=600W m( Incid.Wad =400W/rN txd.irad420DWrt °D 5 10 15 S 25 30 35 0 45 50 V9Ie tvl 4D 0 Vdt09DIVI 5:1517"P- 46C 1lmp 25C 46•C*2 -40 - 85"C DC 1,000V (IEC) DC 1,000V (UL) 15A ( Printed Date: December 20161 HYUNDAI HEAVY INDUSTRIES Lj '(^`, �Jl�"�,Tr ���UInverter /v�.�v/cu nu��./u/o!4c-`�ov TS208-5k75 Specifications Features • Rugged 3-phase 208V plug & play system • Sma and Iight (hand holdable, 24 Ib.) • Non -isolated inverter for use with ungrounded DC systems • Peak 98% efficiency, 97% CEC • 200-850V MPP voltage range for 600V and 1/000V systems • 5.75kW-full power MPP voltage range J25'5Z5V Two DC stnng inputs with independent monitoring and MPPT • Waterproof NEMA6, silent convection cooling • Designed for high reabiity, uses no electrolytic capacitors • Wide temperature range, -40 to +65 °C • Utility -Interactive; Listed to UL1741 • Compliant with NEC 690.11 arc detection Note Operates on 5 -wire wye - neutral must be connected or damage may result Applications • Rooftop commercial, usable where other solutions just won't work - for exampe coastai, desert, highaKitudc|ocationo • Car ports, parking and shade structures; units may be mounted at any orientation, under modules, on racking TS208-5k75 Specifications Maximum open circuit voltage per String, Voc 1,000 VD, Full power MPPT range, per string 325-5�5 Vac PV start voltage Zoo Vac DC allowable stacking ratio (total, 2 inputs combined) Must not exceed 8.9 under any circumstances' DC maximum input current, per DC input io A DC maximum input short circuit current 3oA DC maximum input source back feed current to input source oA DC disconnect means The DC connector has been evaluated and approved for use as the load -break disconnect required by the NEC2 AC maximum continuous total output power to +45 °C 5.75 kWAc max AC de -rate with temperature, +4o to +65 °C -102 W/ °C AC maximum continuous output current, per phase t6.o A AC maximum output over current protection 6o A AC 3-phase system compatibility 208V Wye, 3 phases, neutral and ground AC voltage range, phase to phase (min / nominal / max) 183 / 208 / 229 V (Limits adjustable, see below) AC voltage range, phase to neutral (min / nominal / max) 106 / 120 / 132 V (Limits adjustable, see below) AC output frequency range (min / nominal / max) 59.3 / 6o / 60.5 Hz (Limits adjustable, see below) Power Factor Zo.98 Note 1: Stacking: On the DC side of the inverter, each input limits at 3 kW and/or 1oA, and the combined total AC output is limited to 5.75 kW. Higher DC STC string powers may be applied, the inverter will limit as described above. Total stacking for inverter must not exceed 8.9 under any circumstances Note 2: NEC section 690.17, allowed by the exception of meeting requirements specified in 690.33 Page 2 TS208-5k75 Specifications ." Page 3 AC Jower frequency trip limit Default 59.3 Hz +/-8JHZ Adjustment 57-59.3 Hz in m.1Hzincrements Clearing time default o'16s +1-acycles Cearing time adjustment 0'16'500 AC upper frequency trip timit Default 6o.5 Hz +/-n'1Hr Adjustment 60.5'82.0 Hz in o.i Hz increments Clearing time default 0.16 s +/-zcydes Clearing time adjustment 0.16'300 s AC tower voltage trlp limit (Phase to Neutral) Default 106 +/- 2 % Adjustment 96-106 V Clearing time defautt as +/-zcydes Clearing time adjustment 1'20 5 AC upper voltage trip limit (PhasetoNeutral) Default 132 V +/-a% Adjustment 129-134 V Clearing time defautt 1s +�acycles Ctearing time adjustment 1-205 AC reconnect delay Default 5mninutes 41s Adjustment 1 s'1ominutes AC synchronization in -rush current o A Maximum outputfault current and duration 16/\x0.5ms AC minimum wire gauge for grid connection 12 AWG AC disconnect means The AC connector has been evaluated and ap- proved for use as the load -break disconnect required by the NEC2 Peak efficiency u8% CEC efficiency 97% Dimensions 475n334x76nnrn(183/4x131°x3") Weight 11hg/24|b.1 Operating temperature range `4oto+65"C (-40 to 150 °F) Power consumption standby/ night «4'5VV/<4'5VV Cooling Natural convection, no fan Communication Powerline Environmental rating Outdoor / rooftop, NEMA 6,\P67 Certification Listed tmUL1741/IEEE 1547(Utility Interactive) CSA Czu'zNO. 1o7'1,FCC Part 15,meets the requirements of NEC 690.11 Included warranty 10Years, optionally extendable Page 3 TS208-5k75 Specifications Item Part Number Description TrueString System TS208-5k75 TrueString 208V Inverter, 5.75kW, 3-phase. inverter with MC4- compatible connectors. MPPT per string, monitoring per string. Includes 10 year limited warranty. Does not include Gateway. Does not include AC cable, must be ordered separately. TS208-5k75-AUX TrueString 480V TrueString Inverter, 5.75 kW, 208V 3-phase, with Aux Connector. Inverter with MC4-compatible connectors (lea). MPPT per string, monitoring per string, RS485 communication and Aux connector. Includes 10 year limited warranty. Does not include Gateway. Does not include AC cable, must be ordered separately. TS208-5k75-W25 Option - TrueString System Warranty Extension to 25 years for 1 TrueString 208V. Must be ordered at time of system purchase. Includes system Gateway(s). TrueString AC Cables CBL -208A -o5 TrueString 208V AC Cable, 5ft. Includes TrueString 208V AC mating connector, other end unterminated. CBL -208A-15 TrueString 208V AC Cable,15ft. Includes TrueString 208V AC mating connector, other end unterminated. CBL -208A -3o TrueString 208V AC Cable, 3oft. Includes TrueString 208V AC mating connector, other end unterminated. CBL -208A -5o TrueString 208V AC Cable, Soft. Includes TrueString 208V AC mating connector, other end unterminated. HiQ Communication ' GW -A Solar �mw/����\���{}� uoo-r� Specifications While HIq Solar inverters can operate without one, a wealth of mand control becomes available when a HiQ Communications Gateway is added to the system. It communicates with local inverters over the power Iine by being plugged into one phase, and uses a propnetary communication method that is robust and reliable. Instigating aut�discover on the device will cause it to quicky search out newly added inverters and report back. Once connected to Hiq inverters, the Gateway togs data in near -real-time and stores it on an internal SD card. Up to 10 years of data may be archived this way. Inforrnation may be accessed through the touch screen, or over an Ethernet network. The network connection gives access to the built-in web server, aflowingcomplete control through a web browser. Features • Touchscreen display • Communication over power line with inverters • Ethernet connection for connection to a Iocal LAN • SD card storage of up to 10 years of data • Diagnostic USB port may be used to power other |nwpovverdevices • Communications Gateway is for indoor use only '�� Gateway Specifications Communications Specifications Gaal AC input voltage, min/nom/max 100/120/135 V (244/277/305 V with CBL-GW277A-6) AC frequency, min/nom/max 59.3/60.0/60.5 Hz Operating ambient temp range -20 to +50 °C Power consumption 1.5 W typical (4 W max) Mounting, environmental rating Indoor - NEMA 1 Memory card SD compatible, 4-32GB tested, FAT32 formatted Communication with HiQ Solar Liberty 480V Inverter Proprietary Power Line Communication LAN connection, Ethernet to/1ooBASE, RJ45 8P8C modular plug USB port HiQ diagnostic port, but may be used to power low power external devices (5V, <400mA) Limited warranty 10 years, optionally extendable Certification, communications gateway UL 60950-1, CSA C22.2 No. 60950-1, FCC Part 15 Weight 1.3 lbs Dimensions Mounting plate: 71/2 x 4" (190 x 101 mm) Enclosure: 5'/2 x 4 3/4 X 1'/," (140 x 121 x 38 mm) tlrguide Item Part Number Description Communications Gateway GW -A -12o Communication Gateway l2oV. GW -A Communication Gateway (lea). Includes Ethernet Cable (lea), memory card for logging and storage of results and CBL-GW12oA-6 120V power cable. GW -A-277 Communication Gateway, 277V. GW -A Communication Gateway (lea). Includes Ethernet Cable (lea), memory card for logging and storage of results and CBL-GW277A-6 277V converter power cable. 5/2/2019 City of Tukwila Department of Community Development ELLA WILLARD-SCHMOE 805 RAINIER AVE S SEATTLE, WA 98188 RE: Permit Application No. EL18-1092 STERLING SOUTHCENTER- SOLAR 407 BAKER BLVD Dear ELLA WILLARD-SCHMOE, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 12/19/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 6/19/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) lithe plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Kandace Nichols Permit Technician File No: EL18-1092 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 o PERMIT COORD COPY PLAN REVIEW/ROUTING SLID' PERMIT NUMBER: EL18-1092 DATE: 07/30/19 PROJECT NAME: STERLING SOUTHCENTER - SOLAR SITE ADDRESS: 407 BAKER BLVD Original Plan Submittal Revision # before Permit issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Building Division Public Works n Fire Prevention Structural C Planning Division Permit Coordinator • PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/01/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/29/19 Approved Corrections Required n Approved with Conditions n ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 C PERMIT COORD COPP PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-1092 DATE: 12/19/18 PROJECT NAME: STERLING SOUTHCENTER - SOLAR SITE ADDRESS: 407 BAKER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: fr"? Building Divisio Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/20/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 1/17/19 Approved Approved with Conditions ri Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 12 Fire Ping D PW Staff Initials: 12/18/2013 PROJECT NAME: / I_ ,S0,,c&ce,,fie„- - Si/PERMIT NO: /j)/ SITE ADDRESS: 7 .41, l3/id ORIGINAL ISSUE DATE: 6- /0-/ REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 7-20-P9 Summary of Revision:,1061 sidgw- aideitdx made./ 11 (A.141 bee -1 1 ncreas.ed 10h)t fr- e -lot -4---% by Se.—:_ 1440-itc.cfac-AiA_Ve r Received by: , , 7 i ,..,-,..--,------ REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hap IAN «1v .Tukwila WAo� Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7/18/19 Plan Check/Permit Number: EL18-1092 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑x Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Sterling Southcenter - Solar Project Address: 411 Baker Blvd Contact Person: Ella Willard-Schmoe Phone Number: 206-661-7601 Summary of Revision: Changed solar module model number, increased power class by same manufacturer. Old model number HiS-S355RI. New model number HiS-S360RI. This increased DC system size slightly. Inverter company was acquired and changed names, but is the same exact inverter as previously reviewed, just under a different name (ProHarvest now, instead of HiQ). RECEIVED CITY OF TUKWILA JUL 30 2019 PERMIT CENTER Sheet Number(s): PV -602. module and inverter data sheets "Cloud" or highlight all areas of revision including date of revio. Received at the City of Tukwila Permit Center by: ycj-- Entered in TRAKiT on 7-3a W:\Pencil Center\Templatea\PormelRevision Su Revised: Augurs 2015 Form.d Washington State Department of Labor & Industries Home Espiiiiol Con!act !Searcn L&I Safety & Health Claims & Insurance A -Z index Help \lv II Workplace Rights Trades & Licensing PUGET SOUND SOLAR LLC Owner or tradesperson Principals Burton, Pamela, PARTNER/MEMBER Smithson, Jeremy J, PARTNER/MEMBER Smithson, Jeremy J, AGENT Doing business as PUGET SOUND SOLAR LLC WA UBI No. 602 584 534 5308 Baker Ave NW SEATTLE, WA 98107 206-706-1931 KING County Business type Limited Liability Company Governing persons PAMELA BURTON JEREMY JAMES SMITHSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. PUGETSS920RH Effective — expiration 12/08/2008— 12/08/2020 Designated administrator Smithson, Jeremy J Active. Meets current requirements, License type License no. Electrical Administrator SMITHJJ925QQ Bond Wesco Insurance Co Bond account no. 46WB046099 $4,000.00 Received by L&I Effective date 04/11/2014 04/20/2014 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. License Violations Help us improve SOLAR PV SYSTEM - 29.5 KW DC FEEDER SCHEDULE SOLAR MODULE MPP VOLTAGE HYUNDAI HIS-S360RI 39.1 V T MULTICONDUCTOR CABLE BY INVERTER MANUFACTURER (16) #10 THWN-2 + (1) #10 GND IN 1.5" EMT MPP CURRENT 9.2 A (4) #4 THWN-2 + (1) #8 GND IN 1 1/4" EMT OPEN CIRCUIT VOLTAGE 47.4 V (2) #12 THWN-2 + (1) #12 GND IN 3/4" EMT SHORT CIRCUIT CURRENT 9.8A VOC TEMP COEFFICIENT -0.3 %/°C STRING LENGTH 10OR11 STRINGS PER INVERTER 2 IN DESIGN TEMPERATURE 10°F MAX SYSTEM VOLTAGE 586 VDC MAX SYSTEM CURRENT 12 A DC PER STRING / 64 A AC COMBINED /N /N / N INVERTER SPECIFICATIONS MANUFACTURER & MODEL PROHARVEST PR0208-5K75 ,INVERTER RATED POWER 5.75 KW INVERTER RATED CURRENT 16 A @ 208V 3c1) WYE �AX INPUT VOLTAGE 1000V DC PPT VOLTAGE RANGE 325 TO 525 V DC MAX INPUT CURRENT 10 A x 2 INPUTS CERTIFICATION UL1741, IEEE1547 /N /N /N. /N. ,/`\ /`\ /`\ /N. /N. /N. /N. /N. n /\ /N /N. /\ /\. /N. n INV -1 INV -2 O PULLBOX PV MLO PANELBOARD 120/208 34) 4W 125 A NV -3 20A 3P 0 0 20A 3P 0 20A 3P INV -4 0 0 20A 3P 20A 1P 0 FLAG NOTES PV INTERCONNECTION BREAKER MUST BE LOCATED AT OPPOSITE END OF BUSBAR FROM MAIN OCPD SOLAR PRODUCTION METER MUST BE CO -LOCATED WITH PSE NET METER li)M°' CONDUIT BETWEEN ROOF AND MAIN ELECTRICAL ROOM, FURNISHED & INSTALLED BY E.C. ae> PV SYSTEM DISCONNECT TO BE CO -LOCATED WITH PRODUCTION METER, UTILITY -VISIBLE, LOCKABLE OPEN DISCONNECT 100A DAS SOLAR MONITORING BOX o INTERNET CONNECTION PROVIDED BY E.C. PANEL M-1 120/208 34) 4W 800 A PRODUCTION METER 7—JAW MANUAL BLOCK BYPASS 100A GENERAL LINE DIAGRAM NOTES: 1. NEC 690.12 RAPID SHUTDOWN REQUIREMENTS ARE MET BY LOCATING THE INVERTERS WITHIN THE ARRAY 2. FEEDERS ARE COPPER UNLESS OTHERWISE NOTED 3. CONDUITS MAY BE SIZED UP FOR EASE OF INSTALLATION IF DESIRED LEGEND J MDP120/208 34) 4W 2500 A o-- 80A 3P 0 0— 0 SOLAR MODULE JUNCTION BOX BREAKER ELECTRICAL WIRING DATA CABLE 800A 3P 0 0— CT 120 DIETER 208 34) UTILITY SERVICE tlECEIVED CITY OF TU KWILA JUL 30 2019 PERMIT CENTER PUGET SOUND SOLAR 805 Rainier Ave S Seattle, WA 98144 Tel: 206-706-1931 REVIEWED FOR CODE COMPLIANCE APPROVED Tiz' AUG 07 20194 t City of Tukwila BUILDING DIVISION FILE COPY Permit No. plan review approval is subject to errors ana omi sions Approval of construction documents does authorize the violation of any adopted code or o dinance Receipt of approved Field Copy and conditions is acKnowiedged: By. Date: City of Tukwila BUILDING DIVISION 407 BAKER BOULEVARD TU KW I LA, WA 98188 0 rn 0 z 0 1— w >m O z 0 0 0 W Cn C/) CLC w J X CO z 0 w 1- 0 LL 0 J ›- 0 O Z SEPARATE PERMIT R?UIRED. FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION 0 REVISIONS No changes shall be made to the scope p of work wltnout prior approval of the LU Tukwila Building Division. NOTE: Revisions will require a new plan bmtatal and may include additional plan rev O No c! of worn ,. TUKV\ la N DTE: subm ttal and A REV 1 LAYOUT 05/14/19 FOR CONSTRUCTION 02/06/19 PERMIT SET 06/11/18 REV DESCRIPTION DATE DRAWN BY CHECKED BY PROJECT NO. EWS JH 9429 ROOF MAIN ELECTRICAL ROOM ELl?1O9Z SINGLE LINE DIAGRAM PV -602 PI I 'Ai plan ian review. SOLAR PV SYSTEM - 29.11 KW DC SOLAR MODULE HYUNDAI HIS-S355RI MPP VOLTAGE 38.9 V MPP CURRENT 9.1 A OPEN CIRCUIT VOLTAGE 47.3 V SHORT CIRCUIT CURRENT 9.6 A VOC TEMP COEFFICIENT -0.3 %/°C STRING LENGTH 10 OR 11 STRINGS PER INVERTER 2 MIN DESIGN TEMPERATURE 10°F MAX SYSTEM VOLTAGE 578 VDC MAX SYSTEM CURRENT 12 A DC PER STRING / 64 AAC COMBINED INVERTER HIQ TS208-5K75 INVERTER RATED OUTPUT 16A - 208V 34) WYE FEEDER SCHEDULE co MULTICONDUCTOR CABLE BY INVERTER MANUFACTURER 2 (16) #10 THWN-2 + (1) #10 GND IN 1.5" EMT la (4) #4 THWN-2 + (1) #8 GND IN 1 1/4" EMT ® (2) #12 THWN-2 + (1) #12 GND IN 3/4" EMT /N. ./N • /\ /\ /\ /\ /\ /N. /\ ./N. /N /N. /\ ./\ /N /N • /X /N. /N. /N. /N. /N. /N/ ./X/ ./N/N./N. /N ./N INV -1 INV -2 INV -3 0 PULLBOX O PV MLO PANELBOARD 120/208 34) 4W 125 A 20A 3P 0 20A 3P 0--- 20A 20A 3P INV -4 0 0 20A 3P 0 20A 1P 0 FLAG NOTES PV INTERCONNECTION BREAKER MUST BE LOCATED AT OPPOSITE END OF BUSBAR FROM MAIN OCPD SOLAR PRODUCTION METER MUST BE CO -LOCATED WITH PSE NET METER Ow- CONDUIT BETWEEN ROOF AND MAIN ELECTRICAL ROOM, FURNISHED & INSTALLED BY E.C. DISCONNECT 100A DAS SOLAR MONITORING BOX ROOF INTERNET CONNECTION PROVIDED BY E.C. PANEL M1 120/208 34) 4W 800 A PRODUCTION METER 7 -JAW 100A GENERAL LINE DIAGRAM NOTES: 1. NEC 690.12 RAPID SHUTDOWN REQUIREMENTS ARE MET BY LOCATING THE INVERTERS WITHIN THE ARRAY 2. FEEDERS ARE COPPER UNLESS OTHERWISE NOTED 3. CONDUITS MAY BE SIZED UP FOR EASE OF INSTALLATION IF DESIRED LEGEND J MDP120/208 31) 4W 2500 A 0 0- 80A 0 0— 0 b 800A 3P 0 0- SOLAR MODULE JUNCTION BOX BREAKER ELECTRICAL WIRING DATA CABLE UTILITY SERVICE MAIN ELECTRICAL ROOM FuGET SOUND SOLAR PUGET SOUND SOLAR 805 Rainier Ave S Seattle, WA 98144 Tel: 206-706-1931 EVISIONS No changes call be made to the scope of work wit )ut prior approval of the Tukwil Building Division. NOTE: Revise ns will require a new plan submittal and may include additional plan review. 0 00 \< co W co J o) Q O � CO W CO D d' wQ � 00 u) a 1— z0z az 0 0 O U�Ctri '� 0 0 0- o W m ca O m tY a. cf)� zz 0Q O CL �cr) W w -' W� O Ct T � 1— u) O 0 w W O 0 z 0 00 LL 0 CLw CC 0 w 1— o O co I- T cn I-- 0 PERMIT SET 06/11/18 REV DESCRIPTION DATE DRAWN BY CHECKED BY PROJECT NO. MZ MZ 9429 0 SINGLE LINE DIAGRAM PV -602 SEPARATE PERMIT REQUIRED. FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION C{hi of Tukwila @UiLDING DIVISION FIL Permit No. Plan review approval is subject to errors and nssions Approval 7f construction documents does of auth: nze the violation of any adopted code or ordinance Receipt of approved Field Copy and conditions is acknowledged: Date: jto I I"1 City of Tukwila BUILDING DIVISION CITRECEED Y OF 1 UKWILA DEC 19 2018 PERMIT CENTER