City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
August 21, 2015
NOTICE OF DECISION
TO: Colin Robinson
Cascadia PM
733 7th Avenue, Suite 209
Kirkland, WA 98033
This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project
and permit approval.
I. PROJECT INFORMATION
Project File Number: L15-0041, PL15-0034
Applicant: Colin Robinson, Cascadia PM (obo T-Mobile)
Type of Permit Applied for: Type 1 Wireless Telecommunications Facilities Permit
Project Description: Approval of a Type I Wireless Telecommunication Facilities
Permit to upgrade existing panel antennas and remote radio units and
associated cabling on an existing non -concealed building mounted
wireless facility.
Location: Tax Lot NO: 0923049120. This tower is located at 12201 Tukwila
International Boulevard, Tukwila, WA 98168.
Associated Files: D15-0184
Comprehensive Plan
Designation/Zoning
District:
Commercial Light Industrial (C/LI)
II. DECISION
SEPA Determination: The City SEPA Responsible Official has previously determined that this application
does not require a SEPA threshold determination because it is categorically exempt.
Page 1 of 3 08/21/2015
\\tukdata2k12\DCD Common$\Users\Laura \Wireless Facilities\L15-0041\L15-0041 TMobile TIB NOD.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665
Decision on Substantive Permit: The City Community Development Department has determined that the
application for a Type 1 Wireless Communications Facility does comply with applicable City and state code
requirements and has approved that application without conditions.
III. YOUR APPEAL RIGHTS
The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code
§18.104.010. Other land use applications related to this project may still be pending.
No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing
Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to
challenge either the conditions which were imposed by the MDNS decision or the failure of the Department
to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing
Examiner.
A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in
King County Superior Court from the Hearing Examiner's decision.
IV. PROCEDURES AND TIME FOR APPEALING
In order to appeal the Community Development Director decision on the Permit Application, a written
notice of appeal must be filed with the Department of Community Development within 14 days of the
issuance of this decision.
The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal
materials shall be submitted to the Department of Community Development. Appeal materials MUST
include:
1. The name of the appealing party.
2. The address and phone number of the appealing party; and if the appealing party is a corporation,
association or other group, the address and phone number of a contact person authorized to
receive notices on the appealing party's behalf.
3. A statement identifying the decision being appealed and the alleged errors in the decision,
including any specific challenge to an MDNS.
4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in
the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief
sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal.
5. Appeal fee of $591 plus retainer.
Page 2 of 3 08/21/2015
V. APPEAL HEARINGS PROCESS
Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the
Hearing Examiner based on the information presented to the Community Development Director, who
made the original decision. No new evidence or testimony will be permitted during the appeal hearing.
Parties will be allowed to present oral argument based on the information presented to the Community
Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is
the City's final decision.
Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal
pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a
DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's
decision is properly filed in Superior Court within such time limit, the Decision on this permit will be
final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending
permit applications for the development of the subject property.
VI. INSPECTION OF INFORMATION ON THE APPLICATION
Project materials including the application, any staff reports, and other studies related to the permits are
available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd.,
Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The
project planner is Max Baker, who may be contacted at 206-431-3662 or via email at
max.baker@tukwilawa.gov for further information.
Property owners affected by this decision may request a change in valuation for their property tax
purposes. Contact the King County Assessor's Office for further information regarding property tax
valuation changes.
Department of Community Development
City of Tukwila
Page 3 of 3 08/21/2015
i \
. , Cif* al . .
Jul
Department Of Community Development
AFFIDAVIT OF DISTRIBUTION
I, Laura Benjamin, HEREBY DECLARE THAT:
Notice of Application
X
Notice of Decision
Notice of Public Hearing
Notice of Public Meeting
Determination of Non-
Significance
Mitigated Determination of Non -
Significance
Short Subdivision Agenda
Determination of
Significance & Scoping
Notice
Notice of Application for
Shoreline Mgmt Permit
Shoreline Mgmt Permit
Board of Appeals Agenda
Packet
Board of Adjustment Agenda Packet
Official Notice
Notice of Action
Other: Application Expiration Notice
Was mailed to each of the addresses listed/attached
on this 21st day of August, 2015
Project Name: SE03545A T-MOBILE
Project Number: L15-0041
Associated File Number (s): PL14-0034
Mailing requested by: Laur Benjamin
Mailer's signature:
i
W:\USERS\LAURA\AFFIDAVIT OF DISTRIBUTION.DOC
Colin Robinson, Cascadia PM (applicant)
Colin.robinson@cascadiapm.com
W:\USERS\LAURA\AFFIDAVIT OF DISTRIBUTION.DOC
CASCADIAPM
July 21, 2015
Department of Community Development
6300 Southcenter Blvd., #100
Tukwila, WA 98188
Precision Program Management
Re: T-Mobile Wireless Communications Facility (WCF)
T-Mobile Site Name: SE03545A Pacific HWY & 116th
Site Address: 12201 Tukwila International BLVD Tukwila, WA 98168
Parcel Number: 0923049120
Legal Description: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89-16-35 E 100 FT TH S 24-13-
53 E 969.61 FT TO POINT OF BEGINNING TH N 65-46-07 E 58.17 FT TH N 63-32-48 E 62.13 FT TH
S 22-47-01 E 21.44 FT TH N 65-30-25 E 199.33 FT TO POINT ON WLY R/W LINE OF PRIMARY
STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1-K APPROVED JULY 23, 1957 TH
FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO
RIGHT, CENTER BEARING S 65-44-51 W, THRU C/A OF 1-16-30 DISTANCE OF 62.42 FT TH
FOLLOWING SAID WLY R/W LINE N 67-01-21 E 10 FT TH FOLLOWING SAID WLY R/W LINE ALONG
ARC OF 2815 FOOET RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 67-01-21 W
THRU C/A OF 6-31-21 DISTANCE OF 320.45 FT TH S 73-32-42 W 16.58 FT TH S 71-35-51 W 61.96
FT TH N 78-38-58 W 7.83 FT TH S 75-53-44 W 106.07 FT TH N 05-01-10 W 18.41 FT TH S 82-22-
27 W 64.93 FT TH S 63-55-24 W 58.16 FT TH N 24-13-53 W 334.22 FT TO POINT OF BEGINNING -
LOT B OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98-0033 RECORDING NO
9810059013
To Whom It May Concern:
Oh behalf of T-Mobile, Cascadia PM is pleased to submit for a modification of an existing wireless
communications facility. The proposed modification consists of changes to an existing rooftop site. The
modifications will consist of the removal of 3 existing panel antennas, addition of 3 new panel antennas
and the addition of 3 remote radio units with cablin."
Please find enclosed:
Application Checklist
WCF Application Form
General Application Form
Construction Drawings
Structural Analysis
NIER Study
Check # 003141851 for $620.55 and Check #003141850 for $24.12
RECE,VED
CITY OF TUKWILA
JUL 2 1 2015
PERMIT CENTER
The site is an existing unmanned wireless communications facility so a parking plan is not applicable.
Similarly, landscaping, irrigation, erosion and grading plans are not applicable because it is an existing
rooftop site and no changes are being made to the ground. A noise study is also not applicable because
Cascadia PM. LLC
Corporate Headquarters
3322 South Bay Road NE
Olympia. 'JVA 98506
360 438 8002
, w.cascadiapm.com
130 N. Nimitz Hwy Suite A-200
Honolulu, HI 96817
808 536 7400
5501 NE 109' Ct Suite A-2
Vancouver WA 98662
360 885 9200
15 01'64-
733 Seventh Ave Suite 209
Kirkland, WA 98033
425 828 1008
no new noise generating equipment is being added to the site. This modification its exempt from SERA
per WAC 197-11-800 (25) (a)(i). The site does not include any sensitive areas and all equipment is on the
roof.
The equipment cabinets are located behind a penthouse screen wall that is painted to match the
building. The antennas are flush mounted to the penthouse and will be painted to match the color of
the building. The antennas will not be higher than the penthouse walls. The coax is located below the
parapet of the rooftop and is not visible from the ground.
p
If you have any questions or inquiries regarding this application please feel free to contact me.
Thank you,
Colin Robinson
Zoning Specialist
360-561-3311 Cell
733 7th Avenue, #209
Kirkland, WA 98033
0400
City of Tukwila
Department of Community Development
File Number
L15-0041,
1 PL15-0034,
D15-0184
LAND USE PERMIT ROUTING FORM
TO: ❑I Building
d1I
Planning
Public Works ❑J Fire Dept.
Police Dept. I❑I Parks/Rec
Project: SE0345A T-Mobile
Address:
12201 TIB, 98168
Date
transmitted: 07/31/2015
Response
requested by: 08/10/2015
Staff
coordinator:
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
CoM merits TfrL-T
Plan check date:
Ore?'c E '
Comments
prepared by:
Update date:
0400
City of Tukwila
Department of Community Development
File Number
L15-0041,
PL15-0034,
D15-0184
LAND USE PERMIT ROUTING FORM
TO: yt Building ❑ Planning
Public Works ILJ Fire Dept.
Police Dept. U Parks/Rec
Project: SE0345A T-Mobile
Address:
12201 TIB, 98168
Date
transmitted: 07/31/2015
Response
requested by: 08/10/2015
Staff
coordinator:
Date response
received:
REVIEWERS: Please specify how the attached plans conflict wuth your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
474-
�OI41 / teK /l , , :7;
Plan check date:
Commentsdi
prepared by:
Update date:
0400
TO:
City of Tukwila
Department of Community Development
RECE1Vr-
'JUL 312015
TuKsiviLik
PUBLIC WORKS
File Number
L15-0041,
PL15-0034,
D15-0184
LAND USE PERMIT ROUTING FORM
Building
Planning
Public Works
1❑1
Fire Dept.
Police Dept.
Parks/Rec
Project: SE0345A T-Mobile
Address:
12201 TIB, 98168
Date
transmitted: 07/31/2015
Response
requested by: 08/10/2015
Staff
coordinator:
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
Public Works his no Commvrlr 7's:
Plan check date:
048/0 SI/ 5-
Comments
prepared by: J OQ,Vi Vl0, S
Update date:
l\
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
NOTICE OF COMPLETE APPLICATION
July 31, 2015
Colin Robinson
733 7th Avenue, #209
Kirkland, WA 98033
Subject: SE03545A T-Mobile, 12201 Tukwila International Blvd., Tukwila, QA 98168
L15-0041, PL15-0034
Dear Mr. Robinson,
Your Wireless Telecommunication Facilities application for a Type 1 permit to make modifications to an existing
wireless facility is considered complete on July 31, 2015 for the purposes of meeting state mandated time
requirements.
This determination of complete application does not preclude the ability of the City to require that you submit
additional plans or information, if in our estimation such information is necessary to ensure the project meets the
substantive requirements of the City or to complete the review process.
This notice of complete application applies only to the permits identified above. It is your responsibility to apply for
and obtain all necessary permits issued by other agencies.
Please feel free to contact me with any questions at (206) 433-7166 or Laura.Benjamin@TukwilaWA.gov.
Sincerely,
Lau}a Benjamin
Assistant Planner
1
Cite of J altoi&a
Department Of Community Development
AFFIDAVIT OF DISTRIBUTION
I, Laura Benjamin, HEREBY DECLARE THAT:
Notice of Application
Notice of Decision
Notice of Public Hearing
Notice of Public Meeting
Determination of Non-
Significance
Mitigated Determination of Non -
Significance
Determination of
Significance & Scoping
Notice
Short Subdivision Agenda
Notice of Application for
Shoreline Mgmt Permit
Shoreline Mgmt Permit
Board of Appeals Agenda
Packet
Board of Adjustment Agenda Packet
Official Notice
Notice of Action
X
Other: Notice of Complete Application
Was mailed to each of the addresses listed/attached
on this 31st day of July, 2015
Project Name: SE03545A T-Mobile
Project Number: L15-0041
Associated File Number (s): PL15-0034,
D15-0184
Mailing requested by: Laura Benjamin
Mailer's signature: Wfr) '
W:\USERS\LAURA\AFFIDAVIT OF DISTRIBUTION.DOC
Colin Robinson (Applicant)
Colin.robinson@cascadiapm.com
W:\USERS\LAURA\AFFIDAVIT OF DISTRIBUTION.DOC
JUL 212015
CITY OF TUKWILA Come opment WIRELESS TELE-
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188 COMMUNICATION
Telephone: (206) 431-3670
FACILITIES
APPLICATION
FOR STAFF USE ONLY Permits Plus Type: P-WIRE
Planner:
File Number: L ! .,-- eiO LAC /
Application Complete Date:
Project File Number: �C /� -' Cz�
Application Incomplete Date:
Other File Numbers: J / / __ U/
NAME OF PROJECT/DEVELOPMENT: SE03545 &116th
BRIEF DESCRIPTION OF PROJECT: Modification of Existing Wireless Communications Facility
CIRCLE TYPE - • TYPE 1 TYPE 2
TYPE 3 (PUBLIC HEARING NOTICE RQD)
LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and
subdivision, access street, and nearest intersection.
12201 Tukwila International BLVD Tukwila, WA 98168
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
0923049120
DEVELOPMENT COORDINATOR :
The individual who:
• has decision making authority on behalf of the owner/applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping development
standards, and
• is the primary contact with the City, to whom all notices and reports will be sent.
Name:
Colin Robinson for T-Mobile
Address: 733 7th Ave Suite 209 Kirkland, WA 98033
Phone: (360) 561-3311 FAX:
E-mail: colin.robinson@cascadiapm.com
Signature: h/1 L. / e & nvt...02---
Date: 07/21/2015
\\deptstore\City Common\TerARevisions In Progress\Wireless Communication Facility-Jan2011.docx
rr■
PACIFIC HWY & 116TH/INTERGATE
12201 TUKWILA INTERNATIONAL BLVD.
TUKWILA, WA 98168
SITE ID: SE03545A
CONSTRUCTION DRAWINGS
PROJECT SUMMARY
THIS PROJECT INCLUDES THE FOLLOWING SCOPE OF WORK:
1. PROPOSED MODIFICATION OF AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY.
MODIFICATIONS TO BUILDING INCLUDE:
• REMOVAL OF (3) EXISTING PANEL ANTENNAS
• ADDITION OF (3) NEW PANEL ANTENNAS
• ADDITION OF (3) REMOTE RADIO UNITS & CABLING
PROJECT VICINITY & AERIAL MAPS
SITE INFORMATION
SITE NAME:
SITE ID:
SITE ADDRESS:
ALPHA SECTOR LATITUDE:
ALPHA SECTOR LONGITUDE:
BETA SECTOR LATITUDE:
BETA SECTOR LONGITUDE:
GAMMA SECTOR LATITUDE:
GAMMA SECTOR LONGITUDE:
PACIFIC HWY & 116TH/INTERGATE
SE03545A
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA98168
47°29'35.8" N (47.493278°)
122°17'37.5" W (122.293750°)
47°29'34.5" N (47.492917°)
122°17'36.6" W (122.293500°)
47°29'35.2" N (47.493111°)
122°17'37.6" W (122.293778°)
SOURCE: 1A
PARCEL NUMBER:
ZONING CLASSIFICATION:
JURISDICTION:
TOP OF (E) BUILDING:
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
0923049120
C/LI
CITY OF TUKWILA
89.9' AGL
(
16.07°
N
TN MN
W41
E
S
PROJECT
LOCATION
DRIVING DIRECTIONS
FROM T-MOBILE BOTHELL OFFICE:
1. GET ON 1-405 N FROM 120TH AVE NE AND NE 195TH ST (1.2 MI)
2. MERGE ONTO 1-405 N (5.4 MI)
3. TAKE THE INTERSTATE 5 S EXIT TOWARD SEATTLE/LYNNWOOD (0.9 MI)
4. KEEP LEFT AND MERGE ONTO 1-5 S (23.9 MI)
5. TAKE EXIT 158 FOR BOEING ACCESS RD (0.2 MI)
6. TURN RIGHT ONTO S BOEING ACCESS RD (0.4 MI)
7. S BOEING ACCESS RD TURNS SLIGHTLY LEFT AND BECOMES TUKWILA
INTERNATIONAL BLVD (1.0 MI)
ESTIMATED DISTANCE: 33 MILES
ESTIMATED TIME: 40 MINUTES
GOVERNING CODES
IBC-2012, INTERNATIONAL BUILDING CODE W/ LOCAL
AMENDMENTS
NEC-2008, NATIONAL ELECTRICAL CODE
AD.A COMPLIANCE
INSTALLATION IS UNMANNED AND NOT FOR HUMAN
HABITATION. HANDICAP ACCESS IS NOT REQUIRED
PER A.D.A.
der ^�
l+ '
PROJECT CONTACTS
APPLICANT
T-MOBILE
19807 NORTH CREEK PKWY N
BOTHELL, WA 98011
PROPERTY OWNER
INTERNATIONAL GATEWAY WEST, LLC
C/O SABEY CORP., FOURTH FLOOR
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
PROJECT CONSULTANT
CASCADIA PM
733 SEVENTH AVE, SUITE 209
KIRKLAND, WA 98033
JIM GASKINS
PH: 425.999.2190
SITE ACQUISITION CONSULTANT
CASCADIA PM
733 SEVENTH AVE, SUITE 209
KIRKLAND, WA 98033
RICK STOCKMANN
PH: 425.890.1437
ZONING & PERMITTING CONSULTANT
CASCADIA PM
733 SEVENTH AVE, SUITE 209
KIRKLAND, WA 98033
RICK STOCKMANN
PH: 425.890.1437
CONSTRUCTION MANAGER
CASCADIA PM
733 SEVENTH AVE, SUITE 209
KIRKLAND, WA98033
MARK RAINEY
PH: 425.533.2666
RF ENGINEER
T-MOBILE
19807 NORTH CREEK PKWY N
BOTHELL, WA 98011
DARRYL SALK
PH: 425.770.0006
STRUCTURAL ENGINEER
VECTOR STRUCTURAL ENGINEERS
9138 S STATE STREET, SUITE 101
SANDY, UT 84070
ROGER T. ALWORTH, S.E.
PH: 801.990.1775
(./-&41
DRAWING INDEX
SHEET
T1.0
GN1.0
A1.0
A2.0
A3.0
A4.0
A5.0
A6.0
RF1.0
DESCRIPTION
TITLE SHEET
GENERAL NOTES
OVERALL SITE PLAN
ENLARGED EQUIPMENT PLAN
ELEVATIONS
ANTENNA DETAILS & PLANS
ANTENNA & EQUIPMENT DETAILS
CONSTRUCTION DETAILS
RF DETAILS
Know what's below.
Call before you dig.
THE INFORMATION CONTAINED IN THIS SET
OF DOCUMENTS IS PROPRIETARY BY
NATURE. ANY USE OR DISCLOSURE OTHER
THAN THAT WHICH RELATES TO T-MOBILE
SERVICES IS STRICTLY PROHIBITED.
SIGN OFF OF FINAL CONSTRUCTION DRAWINGS
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH
REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
CONSULTANT
SIGNATURE
DATE
SITE ACQUISITION
PERMITTING CONSULTANT
RF ENGINEER:
CONST. MNGR.
OPS MNGR.
PROJECT MNGR.
REGULATORY REV.
DEV. MNGR.
T ® a
obile
c
CASCADIA PM
Precision Program Management
*ECTOR n . s n .. w .
Q
,,
4� O� W
41725 G
46.,
LBO
05/29/15
Ss?ONALVIc)
EXP. 1/27/16
1 CPM
PROJECT NO.: 8853 1
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
CUMS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TITLE
TITLE
SHEET
SHEET NO.
T1.0
GENERAL NOTES
1. THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY.
2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE FINAL
INSTALLATION. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND
LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE
FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS AND CONFIRMING THAT THE
WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY
DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER.
4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK.
5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE
LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.
6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH
APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND
COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC
AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS
SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY
SPECIFICATIONS AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE
REGULATIONS.
7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION. THE
CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK
UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT MANAGER AND
WITH LANDLORD'S AUTHORIZED REPRESENTATIVE.
8. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A1OBC WITHIN 5
FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION.
9. THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE, AND KEEP SAME ON SITE
WHENEVER ANY PERSONNEL ARE ON SITE.
10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED
TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF
THE WORK.
11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS,
PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY DAMAGE
THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT MANAGER AND/OR
LANDLORD.
12. ON A DAILY BASIS: KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS,
RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES
IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST. OR SMUDGES OF ANY NATURE.
13. CONTRACTOR TO PROVIDE COMPLETE SET OF AS -BUILT DRAWINGS WITHIN 10 WORKING DAYS OF
PROJECT COMPLETION.
14 WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR
OTHER SIMILAR WORK.
15. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
16 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER
SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL
EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK.
17. ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR REPAIRED TO
MATCH EXISTING.
18. ALL ELEMENTS OF EXISTNG STRUCTURE TO REMAIN INDISTURBED, UNO. EXISTING STRUCTURE IS
ASSUMED TO BE IN GOOD CONDITION, FREE OF DAMAGE OR DETEREORATION. CONTRACTOR TO VERIFY
ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY THIS MODIFICATION AND NOTIFY FOR IF ANY
DAMAGE, DETEREORATION, OR DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THOSE
DEPICTED ON THESE CONSTRUCTION DRAWINGS ARE FOUND.
SPECIAL INSPECTION
1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL
INSPECTOR.
2. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER, ARCHITECT,
STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED.
3.. ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. SPECIAL
INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS.
4. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL USED
IF THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED
DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND
FURNISHES EVIDENCE OF COMPLIANCE.
5. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT CERTIFYING THAT ALL WORK REQUIRING
SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE IN
CONFORMANCE WITH THE APPROVED PERMIT PLANS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS.
STRUCTURAL NOTES
GENERAL STRUCTURAL NOTES:
1. WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS
FOR OTHER SIMILAR WORK.
2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES.
3. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS
SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES,
DUCTS, ETC., UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR
INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC.
4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB
SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND,
INDEMNIFY AND HOLD T-MOBILE AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL
LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF T-MOBILE OR THE
ARCHITECT/ENGINEER.
5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO
NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES
NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND PEDESTRIANS DURING
CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING
FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY
COMPLETED WORK, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL
NOT INCLUDE INSPECTION OF SUCH ITEMS.
6. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF. LOAD
SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE
SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH.
8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES
WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR
SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION
OF THIS WORK.
9. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS.
10. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS.
11. ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E., DRYWALL, PLYWOOD, CEILING PANELS,
ETC.) SHALL BE REPLACED TO MATCH EXISTING.
THE FOLLOWING REQUIREMENTS SHALL BE MET FOR SPECIAL INSPECTION:
A. THE SPECIAL INSPECTOR SHALL BE UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL
ENGINEER.
B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE ARCHITECT/ENGINEER,
AND OTHER DESIGNATED PERSONS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER
DESIGN AUTHORITY AND THE BUILDING OFFICIAL.
C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS
SUPERVISOR STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN
CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS OF THE CODE.
D. COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS.
STANDARD STRUCTURAL STEEL NOTES:
1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM
A123-A123M-02 UNLESS NOTED OTHERWISE.
2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, GRADE A OR A501.
3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC
AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER
TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION", 14TH EDITION.
4. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV. ASTM A307 BOLTS (5/8" DIA. UNO) AND
SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL INCLUDE HEAVY -HEX NUTS AND
STANDARD CUT WASHERS.
5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AND STEEL GRATING MAY USE 5/8" DIA
GALVANIZED ASTM A307 BOLTS U.N.O.
6. ALL STRUCTURAL PIPE ASTM A53, TYPE E OR S, GRADE B.
SPECIAL INSPECTION:
.•
.y
•
1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPCitLIVA
INSPECTOR PER CODE FOR THE FOLLOWING ITEMS:
A. CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE Aft
HOLE SIZE, DEPTH, CLEANLINESS, AND INSTALLATION PER ICC REPORT.
B. PERIODIC FOR HIGH STRENGTH BOLT INSTALLATIONS (A325).
:INSPECT
cop \c).9
DRAWING ABBREVIATIONS
AFF
ABOVE FINISH FLOOR
LF
LINEAR FEET
AGL
ABOVE GRADE LEVEL
MAX
MAXIMUM
AWG
AMERICAN WIRE GAUGE
MECH
MECHANICAL
AC
AIR CONDITIONING
MFR
MANUFACTURER
ADJ
ADJUSTABLE
MGR
MANAGER
APPROX
APPROXIMATELY
MIN
MINIMUM
AZ
AZIMUTH
MISC
MISCELLANEOUS
BLDG
BUILDING
MTL
METAL
CM
CONSTRUCTION MANAGER
MTZL
METALIZE(D)
CAB
CABINET
MW
MICROWAVE
CL
CENTERLINE
NEC
NATIONAL ELECTRICAL CODE
CLG
CEILING
NIC
NOT IN CONTRACT
CLR
CLEAR
NTS
NOT TO SCALE
CO
COPPER
N/A
NOT APPLICABLE
CONC
CONCRETE
OC
ON CENTER
COND
CONDUIT
OD
OUTSIDE DIAMETER
CONST
CONSTRUCTION
OP
OVERHEAD POWER
CONT
CONTINUOUS
OT
OVERHEAD FIBER
CPM
CASCADIA PM
OPP
OPPOSITE
D/C
DRAFTER/CHECKER
PL
PROPERTY LINE
DEMO
DEMOLISH
PLYWD
PLYWOOD
DIA
DIAMETER
PM
PROJECT MANAGER
DIM
DIMENSION
PROJ
PROJECT
DN
DOWN
PROP
PROPERTY
DTL
DETAIL
PT
PRESSURE TREATED
DWG
DRAWING
RO
ROUGH OPENING
EA
EACH
ROW
RIGHT OF WAY
ELECT
ELECTRICAL
RRU
REMOTE RADIO UNIT
ELEV
ELEVATION
REQ
REQUIRED
EQ
EQUAL
SBTC
SOLID BARE TINNED COPPER
EQUIP
EQUIPMENT
SF
SQUARE FEET
EXT
EXTERIOR
SHT
SHEET
FIN
FINISH
SPEC
SPECIFICATION
FLR
FLOOR
SO
SQUARE
FT
FOOT, FEET
SS
STAINLESS STEEL
GA
GAUGE
STL
STEEL
GALV
GALVANIZED
STRUCT
STRUCTURE, STRUCTURAL
GC
GENERAL CONTRACTOR
TOC
TOP OF CONCRETE
GWB
GYPSUM WALL BOARD
TOM
TOP OF MASONRY
GR
GRADE
THRU
THROUGH
GRND
GROUND
TNND
TINNED
HVAC
HEATING, VENTING & AIR CONDITIONING
UBC
UNIFORM BUILDING CODE
HORIZ
HORIZONTAL
UG
UNDERGROUND
HT
HEIGHT
UNO
UNLESS NOTED OTHERWISE
IBC
INTERNATIONAL BUILDING CODE
UP
UNDERGROUND POWER
ID
INSIDE DIAMETER
OF
UNDERGROUND FIBER
IN
INCH
VIF
VERIFY IN FIELD
INSUL
INSULATION
VERT
VERTICAL
INT
INTERIOR
WP
WATERPROOF
JBOX
JUNCTION BOX
W/
WITH
LB(S)
POUND(S)
W/O
WITHOUT
TM®foie
CASCADTA PM
Precision Program Management
fECTOR
. n • I n • ■ n •
05/29/15
0° ,, 'pig,
1.
42725 G
a' L 8� 13
"SiONALS
EXP. 1/27/16
I CPM
PROJECT NO.: 8853
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
CUMS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TIRE
GENERAL
NOTES
SHEET NO.
GN1.0
Z. /5-- Oa e//
PARCEL #: 0923049120
AREA: 2.61 ACRES
\,
(E) ROOFTOP EQUIPMENT (TYP)
(E) SCREEN ENCLOSURE
\ \ (E) PENTHOUSE
(E) BUILDING
•
I -
(E) SUBJECT
PROPERTY LINE (TYP)
T-MOBILE PROJECT AREA
SEE SHEET A2.0
\ ,\
\
DRAWING LEGEND
- - SUBJECT PROPERTY LINE
---- -- — - — — ADJACENT PROPERTY LINE
COAX COAX ROUTE
HYBRID HYBRID CABLE ROUTE
x x x EXISTING FENCE
0 ELEVATION MARKER
DETAIL REFERENCE
Ei
® SECTION MARKER
COMMON ABBREVIATIONS
(E) EXISTING
(N) NEW ABBREVIATIONS CONTINUED
(TYP) TYPICAL ON SHEET GN1.0
V
(E) ADJACENT
PROPERTY LINE (TYP)
NOTE:
SITE PLAN DERIVED FROM; EXISTING DRAWINGS, GIS, AERIAL
IMAGES AND SITE PHOTOS.
3UL 21. Sty
CornmuraY
Cvvelopment
L/scV,
16.07.
S
SCALE: 1" = 50'-0" (11X17)
0' 25' 50' 100'
'1'
■ a
OD1.1e`
CASCADIA PM
Precision Program Management
ECTOR
■ n • r n • • a •
0, T. ALR.o
[F0'
ip 41725 cpil
SSIONA1
05/29/15 EXP. 1/27/16
I CPM PROJECT NO.: 8853 I
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
CUMS,
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TITLE
OVERALL
SITE PLAN
SHEET NO.
Al .0
1
OVERALL SITE PLAN
SCALE: 1" = 25'-0" (22X34)
• i�
(E) T-MOBILE H-FRAME WITH METER
BASE AND UTILITY CABINETS TO REMAIN
(E) SCREEN WALL TO REMAIN
(E) T-MOBILE COVP AT EQUIP.
(TYP. OF 3) TO REMAIN
(12) (E) 7/8" COAX (4 PER SECTOR) AND
(E) T-MOBILE HYBRID FIBER ROUTED W/
(E) COAX (50 LF, 150 LF, & 175 LF)
(E) T-MOBILE FCOA
CABINET TO REMAIN
(E) T-MOBILE ULTRASITE
CABINET TO REMAIN
(E) T-MOBILE PURCELL
CABINET TO REMAIN
W
16.07'
s
1
(E) ENLARGED EQUIPMENT PLAN
SCALE: 3/16" = 1'-0" (11X17)
SCALE: 3/8" = 1'-0" (22)(34)
0'
5' 10'
(E) T-MOBILE H-FRAME WITH METER
BASE AND UTILITY CABINETS TO REMAIN
(E) SCREEN WALL TO REMAIN
(E) T-MOBILE COVP AT EQUIP.
(TYP. OF 3) TO REMAIN
(E) T-MOBILE HYBRID FIBER ROUTED
W/ (E) COAX (50 LF, 150 LF, & 175 LF)
(E) T-MOBILE FCOA
CABINET TO REMAIN
(E) T-MOBILE ULTRASITE
CABINET TO REMAIN
(E) T-MOBILE PURCELL
CABINET TO REMAIN
\\ \\ , - / (1) (N) RECTIFIER IN
(E) T-MOBILE PDU
ti
,U` 212415
con.Imunm
C 7,.fet°P
men,
G f"•��Q/
16.07°
N
TN MN
W E
s
SCALE: 3/16" = 1'-0" (11X17)
0'
5' 10'
T ■ -Mobile
■
CASCADTA PM
►reeisioa Program Management
ECTOR
■ n ■ e
*T'A4.0
44.
di iv
,A
o
1.
VI
tb.417255G,
05/29/15
sgZONALS*-
EXP. 1/27/16
1 CPM
PROJECT NO.: 8853 I
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
CUMS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15,MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TITLE
ENLARGED
EQUIPMENT PLAN
SHEET NO.
A2.0
2
(N) ENLARGED EQUIPMENT PLAN
SCALE: 3/8" = 1'-0" (22X34)
(E) TOP OF PENTHOUSE
■
® ® -�'(j
rl �ll
��JJ
■
ha
89 9
(E) T-MOBILE ANTENNA TIP HEIGHT
Nv 89.0'
\ (E) T-MOBILEOANTENNA TIP E GHT
T-MOBILE ANTENNA RAD CENTER
II
II
82.4'
CASCADIA PM
Precision Program Mans:mum
AI(E)
86.5'
r
(E) T-MOBILE ANTENNA RAD CENTER di
AI /(E) TOP OF PARAPET
79.9'
N. 74.5'
E TOP OF ROOF SURFACE
(E) SCREEN WALL; T-MOBILE EQUIPMENT
LOCATED BEHIND SCREEN WALL
VECTOR
o n • .
73.3'
(E) T-MOBILE PANEL ANTENNAS MOUNTED ON
\\\ (E) PIPE MOUNT (TYP OF 3 PER SECTOR,
TOTAL OF 9; 6 TO REMAIN, 3 TO BE REMOVED)
(E) BUILDING
*CP de NV
ra
�j,_4,f
LG
O �RA25 ,4,
6
_I(E)GRADE0.0'AGL
y
40
05/29/15
4410NALO"'
EXP. 1/27/16
1
EXISTING SOUTH ELEVATION
SCALE: 1"=,o'-0°(z2X3a)
s
so m�—
(E) TOP
OF PENTHOUSE
89.9' $
CPM
PROJECT NO.: 8853
/
PRELIMINARY
(E) TOP OF SCREEN WALL &
Abi(E) T-MOBILE ANTENNA TIP HEIGHT
N. 89.0'N..
(E) T-MOBILE ANTENNA TIP HEIGHT
NO.
DATE
D/C
DESCRIPTION
��yy
82 4' Y
0
04-14-15
GUMS
90% CD REVIEW
Adak (E) T-MOBILE ANTENNA RAD CENTER1
rc
05-18-15
EG/MS
CLIENTNT
86.5'
- - - -
r
2
05-27-15
EG/MS
COMMENT
I
(E) T-MOBILE ANTENNA RAD CENTER ch
a (N) T-MOBILE ANTENNA RAD CENTER
79.9
SUBMITTAL
DATE
D/C
DESCRIPTION
N. 85.0'
(N) T-MOBILE ANTENNA RAD CENTER dh
(E) TOP OF PARAPET
78.4' IliNO.
0
05-29-15
MS/MS,
BP SUBMITTAL
N. 74.5'
E TOP OF ROOF SURFACE
(E) SCREEN WALL; T-MOBILE EQUIPMENT
LOCATED BEHIND SCREEN WALL
SITE NAME:
PACIFIC HWY &
116TH/I NTERGATE
SITE ID:
•
73.3'
(N) MOBILE PANEL ANTENNAS
(TYP OFF 1 PER SECTOR, TOTAL OF
3) MOUNTED ON (E) PIPE MOUNT
(E) T-MOBILE PANEL ANTENNAS MOUNTED ON (E)
PIPE MOUNT (TYP OF 2 PER SECTOR, TOTAL OF 6)
4 15 —•6 0 zi/
(E) BUILDING
S E03545A
SITE ADDRESS:
NOTES:
• IF REQUIRED, PAINT TO MATCH ANTENNAS AND ANCILLARY EQUIPMENT TO MATCH
THE EXISTING STRUCTURE WITH NON -REFLECTIVE PAINT AS REQ'D. CONTRACTOR
TO VERIFY COLOR AND FINISH WITH LANDLORD AND/OR JURISDICTION.
• PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY
CONDITION OF STRUCTURE AT PROPOSED MOUNTING LOCATION TO ENSURE
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TITLE
ELEVATIONS
EXISTINGI
n
t t •"�
• NEW ANTENNAS SHALL NOT EXCEED EXISTING TIP HEIGHT U.N.O.
• RETURN ALL USED EQUIPMENT AND HARDWARE TO T-MOBILE WAREHOUSE.
• ALL CLIMBING PATHS ON TOWER/MONOPOLE TO REMAIN FREE & CLEAR OF
MOUNTS, EQUIPMENT, ETC.
fr-•:-
_ _ _-
A. (E) GRADE 0.0' AGL
SHEET NO.
A3.0
m,1C1\(y 0
v"k e\oP�`���
SCALE: 1" = 20'-0" (11X17)
0' 10' 20' 40'
2
FINAL SOUTH ELEVATION rev
SCALE: 1" = 10'-0" (22X34)
In MI
ANTENNA SCHEDULE - FINAL CONFIGURATION
SECTOR
POS.
EXIST. / NEW
MNFR.
ANTENNA MODEL
PORT
DIMENSIONS
(L x W x D)
WEIGHT
(LBS)
ALPHA
Al
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
A2
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
A3
NEW
COMMSCOPE
SBNH-1D65C-V1
QUAD
96.4" x 11.9" x 7.1"
49.6
BETA
B1
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
B2
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
B3
NEW
COMMSCOPE
SBNH-1D65C-V1
QUAD
96.4" x 11.9" x 7.1"
49.6
GAMMA
Cl
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
C2
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
C3
NEW
COMMSCOPE
SBNH-1D65C-V1
QUAD
96.4" x 11.9" x 7.1"
49.6
*TOWER -
FINAL EQUIPMENT INVENTORY
SCOPE
QTY.
TECHNOLOGY
MNFR.
MODEL
DIMENSIONS
(L X W X D)
WEIGHT
(LBS)
REMOVE (E)
(3)
ANTENNA
ANDREW
TMBXX-6516-R2M
59.0" x 11.9" x 6.3"
(34.6)
(E) TO REMAIN
(6)
ANTENNA
ANDREW
TMBXX-6516-R2M
59.0" x 11.9" x 6.3"
34.6
(E) TO REMAIN
(3)
RRU
NOKIA
FRIG
23.8" x 17.2" x 7.5"
59.9
(E) TO REMAIN
(3)
RRU
NOKIA
FXFB
19.3" x 22.0" x 5.2"
55.0
(E) TO REMAIN
(3)
COVP
RAYCAP
CR100-1076R06
20.2" x 19.0" x 7.0"
15.0
(E) TO REMAIN
(6)
TMA
COMMSCOPE
TMAT1921878-
(TMA STYLE 3C)
9.1" x 8.7" x 4.1"
17.6
ADD (N)
(3)
ANTENNA
COMMSCOPE
SBNH-1D65C-VI
96.4" x 11.9" x 7.1"
49.6
ADD (N)
(3)
RRU
NOKIA
FRLB
15.75" x 15.75" x 5.9"
59.5
*GROUND
- FINAL EQUIPMENT INVENTORY
SCOPE
QTY.
TECHNOLOGY
MNFR.
MODEL
DIMENSIONS
(L X W X D)
WEIGHT
(LBS)
(E) TO REMAIN
(3)
COVP
RAYCAP
RNSNDC-7771-PF-48
18.85" x 16.08" x 5.83"
19.0
" THE "TOWER" AND "GROUND" REFERENCES REFER TO NOMENCLATURE REFLECTED IN THE PLUMBING DIAGRAM ON THE RF1.0 SHEET
AND DO NOT NECESSARILY REFER TO ACTUAL LOCATION OF EQUIPMENT.
GROUND EQUIPMENT NOTE:
• NEW FBBC TO BE INSTALLED IN EXISTING FCOA CABINET (QUANTITIES MAY VARY). ALL OTHER BASEBAND MODULES ARE ASSUMED TO
BE EXISTING.
ANTENNA NOTES:
• REFERENCE OWNERS MANUAL FOR CONNECTION AND MOUNTING INFORMATION FOR AMPLIFIER IF REQUIRED.
• CONTRACTOR SHALL VERIFY FINAL ANTENNA AZIMUTHS W/ CLIENT REPRESENTATIVE PRIOR TO COMMENCING INSTALLATION.
• PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY SUITABILITY OF ANTENNA MOUNT AT SPECIFIED ELEVATION.
• IF REQUIRED, PAINT TO MATCH ANTENNAS AND ANCILLARY EQUIPMENT TO MATCH THE EXISTING STRUCTURE WITH NON -REFLECTIVE
PAINT AS REQ'D. CONTRACTOR TO VERIFY COLOR AND FINISH WITH LANDLORD AND/OR JURISDICTION.
• RETURN ALL UNUSED EQUIPMENT TO T-MOBILE WAREHOUSE.
c2`4‘
GPI
(E) T-MOBILE PANEL ANTENNAS
MOUNTED ON (E) PIPE MOUNT (TYP
OF 3 PER SECTOR, TOTAL OF 9; 6 TO
REMAIN, 3 TO BE REMOVED)
(E) T-MOBILE TMA MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 2
PER SECTOR, TOTAL OF 6) TO REMAIN
(E) T-MOBILE FXFB (RRU) MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 1
PER SECTOR, TOTAL OF 3) TO REMAIN
(E) T-MOBILE FRIG (RRU) MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 1
PER SECTOR, TOTAL OF 3) TO REMAIN
(E) T-MOBILE PANEL ANTENNAS MOUNTED ON
(E) PIPE MOUNT (TYP OF 1 PER SECTOR,
TOTAL OF 3) TO BE REMOVED
(E) T-MOBILE COVP MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 1
PER SECTOR, TOTAL OF 3) TO REMAIN
W
16.07"
N
TN 1 /MN
S
E
2
EXISTING ANTENNA PLAN
SCALE: NTS (11X17)
SCALE: NTS (22X34)
(N) T-MOBILE PANEL ANTENNAS (TYP OF 1
PER SECTOR, TOTAL OF 3) MOUNTED ON
(E) PIPE MOUNT
(E) T-MOBILE TMA MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 2
PER SECTOR, TOTAL OF 6) TO REMAIN
(E) T-MOBILE FXFB (RRU) MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 1
PER SECTOR, TOTAL OF 3) TO REMAIN
(E) T-MOBILE FRIG (RRU) MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 1
PER SECTOR, TOTAL OF 3) TO REMAIN
N
cr
co 11
xx
ao
W
(E) T-MOBILE PANEL ANTENNAS
MOUNTED ON (E) PIPE MOUNT (TYP OF
2 PER SECTOR, TOTAL OF 6)
(N) T-MOBILE FRLB (RRU) MOUNTED
NEAR ANTENNA ON (E) UNI-STRUT
(TYP OF 1 PER SECTOR, TOTAL OF 3)
(E) T-MOBILE COVP MOUNTED NEAR
ANTENNA ON (E) UNI-STRUT (TYP OF 1
PER SECTOR, TOTAL OF 3) TO REMAIN
W
16.07°
N
TN 1 /MN
S
E
SCALE: NTS (11X17)
SCALE: NTS (11X17)
T ®
-Mobile-,
CASCADIA PM
Precision Program Management
)WECTOR n • s
T. AL4,0
ij' oew 44.
y
-Ir.
0 t1725 c,
vitt'
05/29/15
"4570NALVI-
EXP. 1/27/16
CPM
PROJECT NO.: 8853
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
MUMS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TITLE
ANTENNA
DETAILS & PLANS
SHEET NO.
A4.0
1
ANTENNA AND ANCILLARY EQUIPMENT
SCALE: NTS (22X34)
3
FINAL ANTENNA PLAN
SCALE: NTS (22X34)
TOP
FRONT
1-
x
w
x
SIDE
ANTENNA DATA
MECHANICAL SPECIFICATIONS
MANUFACTURER
HEIGHT
WIDTH
DEPTH
WEIGHT
COMMSCOPE
96.4 IN
11.9 IN
7.1 IN
49.6 LBS
PART #
CONNECTORS
STANDARD MOUNTING HARDWARE
SBNH-1D65C-V1
(4) 7-16 DIN FEMALE
INCLUDED
TOP
FRONT
WIDTH
x
O
w
x
DEPTH
NSN FRLB LTE 700 / BAND 12 (REMOTE RADIO UNIT).
HEIGHT: 15.75"
WIDTH: 15.75"
DEPTH 5.9"
WEIGHT: 59.52 LBS
SIDE
1
ANTENNA DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
2
FRLB (RRU) DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
3
NOT USED
SCALE: NTS (11X17)
SCALE: NTS (22X34)
t./6 -aO','
SCALE: NTS (11X17)
SCALE: NTS (11X17)
SCALE: NTS (11X17)
SCALE: NTS (11X17)
.1.
■ DMO
11ea
CASCADTA PM
Precision Program Management
��.ECTOR
n•c
T. ALR.O
sf
'0'
4.-4417255 c
E2NAL 50, li
s'gtONALOG
05/29/15 EXP. 1/27/16
CPM PROJECT NO.: 8853
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
CUMS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA. WA 98168
SHEET TITLE
ANTENNA AND
EQUIPMENT
DETAILS
SHEET NO.
A5.0
4
NOT USED
SCALE: NTS (22X34)
5
NOT USED
SCALE: NTS (22)(34)
6
NOT USED
SCALE: NTS (22X34)
7
NOT USED
SCALE: NTS (22X34)
z
2
4
i
(E) ENCLOSURE WALL
(CORRUGATED METAL SHEATHING
SUPPORTED BY STEEL FRAMING)
(E) 2" STD. (2.375" O.D. X 0.154" THK) MIN.
ANTENNA PIPE MOUNT (REPLACE W/
LONGER PIPE TO ACCOMMODATE
ANCILLARY EQUIP. INSTALLATION IF
NECESSARY)
(N) ANTENNA MOUNT WITH
MECHANICAL DOWN TILT
(N) T-MOBILE ANTENNA - SEE 1/A4.0
(E) SITEPRO B2018 OR EQUAL
SLIDER MOUNT WITH (2) 3/8"0 MIN.
THROUGH BOLTS, TYP (VERIFY)
(E) 4 X 4 X 1/4" STEEL ANGLE
NOTES:
SUITABILITY OF PLATFORM / MOUNT(S) FOR FINAL
LOADING CONFIGURATION TO BE VERIFIED BY OTHERS
PRIOR TO INSTALLATION.
NO WORK SHALL COMMENCE WITHOUT THE
APPROVED STRUCTURAL TOWER / ANTENNA / MOUNT
ANALYSIS REPORT (SIGNED AND SEALED) TO BE
PROVIDED UNDER SEPARATE COVER. CONTRACTOR
PRIOR TO CONSTRUCTION SHALL REVIEW THE
APPROVED TOWER / ANTENNA / MOUNT ANALYSIS
REPORT SUPPLIED BY T-MOBILE AND MODIFY, IF
REQUIRED, ALL APPLICABLE MEMBERS AS INDICATED
IN CERTIFIED STRUCTURAL REPORT PRIOR TO
INSTALLATION ON STRUCTURE.
(E) FXFB MOUNTED TO
UNI-STRUT (TYP OF 3)
(E) FRIG MOUNTED TO
UNI-STRUT (TYP OF 3)
NOTE:
UNI-STRUT MOUNTED EQUIPMENT
TO BE MOUNTED PER
MANUFACTURER SPECIFICATIONS.
•
(E) P1000 UNI-STRUT
AS REQUIRED (TYP)
(E) COVP MOUNTED TO
UNI-STRUT (TYP OF 3)
(N) FRLB MOUNTED TO
UNI-STRUT (TYP OF 3)
(E) ENCLOSURE WALL
STUD (TYP)
1
EQUIPMENT MOUNTING DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22)(34)
2
EQUIPMENT MOUNTING DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
ram''
SkiLTA
Con1mu e t
peve�eP
LiM".1-oacif
SCALE: NTS (11X17)
SCALE: NTS (11X17)
T
® '
Obl1e
CASCADIA PM
Precision Program Management
*® CTOR
■ n • s n ■ ■ w •
4 T. AL.wo�j,
4� oe W ,, 'Y
ff#Nt
tr
O41T25 114.
c'RAL
S`YJONAt$
05/29/15 EXP. 1/27/16
CPM PROJECT NO.: 8853
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
04-14-15
CUMS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA98168
SHEET TITLE
CONSTRUCTION
DETAILS
SHEET NO.
A6.0
3
NOT USED
SCALE: NTS (22X34)
4
NOT USED
SCALE: NTS (22)434)
LTE
AWS
(Alpha)
10 9 8
Bata
Sector
FSMF + •o
FBBC
LTE
LTE s '�
ESMB
GSM
FSME
UMTS
r
.++ [> ,
,''-A t.
Configuration 702A_RUSq - 2015
(Antenna cabling of one sector shown for clarity)
Roof
coup
'/, Quad
Pole
UMTS
PCS
(Alpha)
Man Prnrer
& Filer
FEES
GSM & UMTS
PCS
7705 (CSR)
Soctor
Bata
Sector
Gann.
Surer
•
UMTS
AWS
(Alpha)
FRM
U,WS UMT9
W, UMTS
s (I
RW9 uMi9
FSME
UMTS
D �
Tower
Ground
( Upgraded )
equipment
Reconfigured
equipment
Previous Modernized Confi.:
2A-2 QP•1DP 1QP
N 2A 009
NOTES:
1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED.
2. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY.
3. TAGGING:
• ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO
INDICATE THE ANTENNA SECTOR.
' COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE
AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE.
(NOT TO INTERFERE WITH WATERPROOFING.)
4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY
3'-0" ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS
REQUIRED TO MEET THIS REQUIREMENT.
5. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO
OVERLAP MOVES WATER AWAY FROM CONNECTION (SEE STEP 4).
6. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR QUAD POLES & TMAS.
7. ALL ANTENNAS & COAXIAL ANTENNA CABLE TO BE FURNISHED BY
T-MOBILE AND INSTALLED BY CONTRACTOR.
8. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1"
WIDE WEATHERPROOF COLORED VINYL TAPE AT THE FOLLOWING
LOCATIONS:
#1 - AT ANTENNA CONNECTION
#2 - AT ENTRY TO EQUIPMENT CABINET
9. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK & 12" FROM EDGE OF
EQUIPMENT CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE),
UP TO TOWER LEG (IF APPLICABLE), AND DISTRIBUTE TO EACH
ANTENNA DEVICE. FURNISH AND INSTALL A MINIMUM OF (3) GROUND
KITS PER COAXIAL CABLE. VERIFY NUMBER OF ANTENNAS, CABLE, AND
CABLE DIAMETER WITH T-MOBILE CONSTRUCTION MANAGER.
/C:-00€//
T
11 «Mobile
la
CASCADIA PM
Predhion Program Management
VECTOR
■ n • f n • • w •
CPM PROJECT NO.: 8853
PRELIMINARY
NO,
DATE
D/C
DESCRIPTION
0
04-14-15
CL/MS
90% CD REVIEW
1
05-18-15
EG/MS
CLIENT COMMENT
2
05-27-15
EG/MS
SE COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION ,
0
05-29-15
MS/MS
BP SUBMITTAL
SITE NAME:
PACIFIC HWY &
116TH/INTERGATE
SITE ID:
SE03545A
SITE ADDRESS:
12201 TUKWILA INTERNATIONAL BLVD
TUKWILA, WA 98168
SHEET TITLE
RF DETAILS
SHEET NO.
RF 1.0
1
RF DETAILS - ANTENNA & ANCILLARY EQUIPMENT PLUMBING DIAGRAM
WIRELESS FACILITY
TYPE 1
Parent Project:
PL15-0034
VOID
This File:
L15-0044