Loading...
HomeMy WebLinkAboutPermit PL15-0045 - ROBERT BAIR / CENTURYLINK - S 134TH PL SENSITIVE AREASSPECIAL PERMISSION SENSITIVE AREAS Parent Project: PL15-0045 APPROVED This File: L15-0053 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 2, 2014 NOTICE OF DECISION TO: Robert Bair, CenturyLink Washington State Department of Ecology King County Department of Assessments This letter serves as a Notice of Decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: L15-0053 Applicant: Robert Bair, CenturyLink Type of Permit Applied for: Special Permission from the Director Project Description: Special Permission application to bore a four -foot PVC pipe along the right of way and into a customer conduit. Location: King County Parcel # 2613200045 Associated Files: PL15-0045 (Project File) Comprehensive Plan Designation/Zoning District: Commercial/Light Industrial (C/LI) II. DECISION SEPA Determination: The City SEPA Responsible Official has determined that this application does not require a SEPA threshold determination because it is categorically exempt. Decision on Substantive Permit: The Community Development Director has determined that the Special Permission Application does comply with applicable City and state code requirements and has approved the application with no conditions. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 2 decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the Hearing Examiner of the Decision on the Permit itself is permitted. A party who is not satisfied with the outcome of the administrative appeal process may file an appeal in King County Superior Court from the Hearing Examiner decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director's decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14-days of the issuance of this Decision; that is, by November16, 2014. The requirements for such appeals are set forth in Tukwila Municipal Code 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee per the current fee schedule, additional hourly charges may apply.. In addition all hearing examiner costs will be passed through to the appellant. V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as an open record hearing before the Hearing Examiner based on the testimony and documentary evidence presented at the open record hearing. The Hearing Examiner decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. Page 2 of 2 11/2/2015 W:\Users\Valerie\Notice of Decision\L15-0053 NOD The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Valerie Lonneman who may be contacted at 206-433-7140 or Valerie.Lonneman@TukwilaWA.gov for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Jack P irector Depart it of Community Development City of Tukwila )16,1 Page 2 of 2 11/2/2015 W:\Users\Valerie\Notice of Decision\L15-0053 NOD r City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director STAFF REPORT TO THE DIRECTOR PREPARED November 2, 2015 FILE NUMBER: L15-0053; PL15-0045 APPLICANT: Robert Bair, CenturyLink REQUEST: Approval of Special Permission —Director Permit to bore a four -foot PVC pipe along the right of way and into a customer conduit. LOCATION: 4501 S 134th Pl. SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN DESIGNATION: Commercial/Light Industrial (C/LI) ZONE DESIGNATION: C/LI STAFF: Valerie Lonneman, Assistant Planner ATTACHMENTS: a) Letter from CenturyLink, received October 7, 2015 b) Construction Plans FINDINGS Project Description This project is a request to allow the extension of a telephone and fiber optic line to using a directional bore within the gravel shoulder on the northerly pavement edge of S. 134th P1. and across the street to connect with the existing customer 2" conduit in the access driveway for 4501 S. 134th Pl. The bore will align with horizontal limits of the asphalt access road through the buffer and run over the culvert conveying Southgate Creek under the access road off of S. 134th Pl. Decision Criteria TMC 18.45.070 B. 5. states that essential utilities may be permitted in sensitive areas, subject to approval by the Director of the Department. The criteria are identified in italics followed by the staff response. a. Essential utilities must be constructed to minimize, or where possible avoid, disturbance of the sensitive area and its buffer; 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 L15-0053 CenturyLink Special Permisstua Sensitive Area Departure October 26, 2015 Response: The directional bore is proposed within the buffer and above the culvert conveying Southgate Creek. There will be no intrusion into the free flowing portion of the stream and the project will be above the water table. The bore pits will be restored to their original condition. b. Essential utilities must be designed to protect the sensitive area and its buffer against erosion, uncontrolled storm water, restriction of groundwater movement, slides, pollution, habitat disturbance, any loss of flood carrying capacity and storage capacity, and excavation or fill detrimental to the environment; Response: As noted above, there will be minimal disturbance to the buffer area and the bore pits, which are across the street from the creek and will be restored to their original condition. c. Upon completion of installation of essential utilities, sensitive areas and their buffers must restored to pre -project configuration, replanted as required and provided with maintenance care until newly planted vegetation is established. In addition, mitigation to offset impacts to sensitive areas and mitigation ratios of this chapter. Response: Typically, as a condition of approval for work in a sensitive area buffer, mitigation such as tree planting would be required. In this case, a recent building permit (D13-219) for the new commercial building at 4501 S 1.34' Pl. required several site improvements and buffer mitigation along the southerly margin of the Right of Way. Mitigation work has been conducted and shall not be disturbed as part of this work. d. All crossings must be designed for shared facilities in order to minimize adverse impacts and reduce the number of crossings. Response: Not applicable. CONCLUSIONS 1. The project has demonstrated that it complies with requirements to minimize or avoid disturbance to the sensitive area and its buffer, protect the sensitive area from erosion and other disturbances during construction, and restore the area to pre -project configuration upon completion. RECOMMENDATION Approve the extension of telephone and fiber optic lines using a directional bore on the NW side of S 134th Pl. and across the street, over the culvert that runs under the access driveway for 4501 S. 134`h Pl, to connect with existing conduit. Page 2 of 2 11/2/2015 W:\Users\Valerie\Special Permission\L15-0053 CenturyLink\L15-0053 SR `. City of J uIIwiea Department Of Community Development AFFIDAVIT OF DISTRIBUTION I, Valerie Lonneman, HEREBY DECLARE THAT: Notice of Application X Notice of Decision Notice of Public Hearing Notice of Public Meeting Determination of Non- Significance Mitigated Determination of Non - Significance Short Subdivision Agenda Determination of Significance & Scoping Notice Notice of Application for Shoreline Mgmt Permit Shoreline Mgmt Permit Board of Appeals Agenda Packet Board of Adjustment Agenda Packet Official Notice Notice of Action Other: Was mailed to each of the addresses listed/attached on this 3 day of November, 2015 Project Name: CenturyLink 4501 S 134th P1 Project Number: L15-0053 (S.ecial Permission —Director) Associated File Number (s): PL15-0045 Mailing requested by: Valerie Lonneman Mailer's signature: � W:\USERS\VALERIE\AFFIDAVIT OF DISTRIBUTION.DOC Robert Bair, CenturyLink rob.bair@centurylink.com 'sepaunit@ecy.wa.gov' King County Department of Assessments - 500 yam` �-V2� �'301/1 W:\USERS\VALERIE\AFFIDAVIT OF DISTRIBUTION.DOC City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTICE OF COMPLETE APPLICATION October 23, 2015 Robert Bair 23316 66th Ave E Kent, WA 98032 Rob.bair@centurylink.com Subject: CenturyLink service to new building L15-0053 Dear Mr. Bair: Your application for a Special Permission permit to bore a four inch PVC pipe along the right-of-way and into a customer conduit along the parcel edge at 4501 S 134th Pl. is considered complete on October 23, 2015. This determination of complete application does not preclude the ability of the City to require that you submit additional plans or information, if in our estimation such information is necessary to ensure the project meets the substantive requirements of the City or to complete the review process. This notice of complete application applies only to the permits identified above. It is your responsibility to apply for and obtain all necessary permits issued by other agencies. Please feel free to contact me with any questions at (206) 433-7140. Sincerely, Valerie Lonneman Assistant Planner W:\Users\Valerie\Letter of Completeness Page 1 of 1 10/23/2015 �1 _J COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing by the Public Works Department and the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City Staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning APPLICATION MATERIALS: X 1. Application Checklist one (1) copy, indicating items submitted with application. x 2. Application Fee: See Land Use Fee Schedule. X 3. Written description of the project, the deviation or approval being requested and response to the applicable decision criteria. ZONING CODE PARKING DEVIATION NA 4. A complete description of the proposed construction relative to parking areas, and all supporting agreements. NA 5. Dimensional site plan(s) to demonstrate parking area consistent with Zoning Code requirements. NA 6. Parking studies as needed to demonstrate adequate parking is provided. LANDSCAPE DEVIATION X 7. Landscape plan — two (2) copies showing size and species of existing and proposed plant materials, required perimeter landscape types, parking areas, buildings, walkways, transit facilities, property lines, dimensions and area of planting beds and any calculations necessary to demonstrate compliance with review criteria. SENSITIVE AREA ORDINANCE - Deviations, Alterations or Uses Requiring Administrative Review and Approval X 8. Site Plan — two (2) copies showing all buildings, parking areas, walkways, property lines, planting areas, sensitive areas, their buffers and setbacks. Required Waiver 9. Sensitive area studies, mitigation and enhancement plans to justify a requested use, deviation, alteration or buffer or setback reduction and demonstrate that the reduction will not result in a direct or indirect short - term or long-term adverse impact to the sensitive area per TMC 18.45.090(D) or 18.45.110(C). See TMC 18.45.040(B) for required element s of wetland and/or watercourse sensitive area studies and TMC 18.45.040(C) for the required elements of a geotechnical report. �„ H:\Anplications needing fee verbiage\Special Permission Director -March 2011.docx Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning CARGO CONTAINER APPROVAL 10. Site plan showing the location of the container(s) in relationship to parking areas, property lines, buildings, streets, trails, landscape areas and setbacks. 11. Description of the proposed screening. 12. Dimensions of proposed cargo container. SINGLE-FAMILY DESIGN STANDARD EXCEPTIONS 13. Dimensioned and scalable building elevations with keyed colors and materials. 14. The site plan must include a graphic scale, north arrow, proposed house footprint, any existing structures, lot lines, setbacks, adjacent streets, driveways, parking areas, any sensitive areas and any fences, rockeries or retaining walls. H:\Applications needing fee verbiage\Specie Permission Director -March 2011.docx We are asking for Administrative Review and Approval under 18.45.070, B., 5. Essential Utilities as allowed in the Tukwila Municipal Code. Approval is necessary to extend telephone and fiber optic to 4501 S134th Place, a commercial building nearing completion on the site. The permit for this building is D13-219. Part of the requirements under this permit were to widen the existing access road and install curb and sidewalk on the westerly side of the access road, and to provide buffer mitigation for the unnamed stream which is within the southerly margin of the ROW for S. 134th Place. Prior to installing the side walk the developer provided conduit for gas, telephone and cable TV under the sidewalk and across the drive way . Gas was recently extended to the building under separate ROW permit. Approval under 18.45.070, B., 5 is necessary because the buffer of the unnamed stream extends across the paved section and gravel shoulder of S. 134th Place and also across the 30 foot wide paved driveway that accesses the building at 4501 S. 134th Place. The stream crosses the driveway in a concrete incased culvert. The construction will take place mostly outside the northerly pavement edge of S 134th Place in the gravel shoulder. It will consist of two bore pits, one 140 feet west of the centerline of the driveway of 4501 and one directly across from the center of the driveway, from this location we will bore under S 134th Place and above the culvert and intercept and existing conduit that extends to the building at 4501. Each bore pit will be 5' x 5'. The curb and sidewalk will buffer our construction from the buffer mitigation area. The bore pits will be restored to their original condition. There will be no intrusion into the free flowing portion of the stream, and based on the recent gas installation bore pit at 4.5 feet deep we will be above the water table. This single bore crossing will also enable us to serve the five other businesses in the buildings adjacent 4501 without the need for a separate ROW permit. We ask for a waiver from a sensitive areas study as none of our proposed construction will be out of improved areas. Attached are the mitigation plan for the 4501 Building showing the site layout and adjacent buildings and photos show our proposed bore bits and connection point to the existing conduit. f:GE fi:D OP TUKWILA CITY OF TUKWILA OCR �DECIAL Department of Community Development{ -3115e- 6300 Southcenter Boulevard, Tukwila, V " Y� 449� MISSION - Telephone: (206) 431-3670 C15``� OP l� OG� a'� 2015 DIRECTOR APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-SP Planner: File Number: A ) i- 0053 Application Complete Date: Project File Number: f I� _-0014 Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: CenturyLink service to new building BRIEF DESCRIPTION OF PROJECT: Bore 4' PVC along ROW and into customer conduit in the parcel edge. LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. 4501 S 134th P1 LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 261320-0045 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City to whom all notices and reports will be sent. Name: Kober- !3i iv - Address: 2;3 /o 6 Rv� Phone: 253- 5 72r3SS FAX: E-mail: (0 bet iv- (i cep. ur-.41,1) 1e: cW i-, Signature: / Date: op7//5 H:\Applications needing fee verbiage\Special Permission Director -March 2011.docx City of Tukwila — Centurylink N.005074 permit request @ 4601 S 134th PI Creek alignment per King County mapping. 18" Steel culvert pipe. Existing PSE Gas line recently installed over culvert pipe at 22" depth with concrete cap. Existing 264TA hand hole vault in soil shoulder. Bore 140' from existing 264TA HH to driveway access pit 5'x 5'. Bore 85' from the bore pit in the driveway across S 134th PI into private parcel. Bore will align within horizontal limits of the asphalt access road and will bore over the steel culvert pipe elevation. ECEWED OCT, 02 2015� TUKWIL A PUBLIC WORKS LI5-pp53 1of3 ?&,-o/ yS City of Tukwila — Centurylink N.005074 permit request @ 4601 S 134th PI .. Bore 85' from the bore pit in the driveway across S 134th PI into private parcel and connect to existing customer 2" conduit. Bore will align within horizontal limits of the asphalt access road and will bore over the steel culvert pipe elevation. Existing PSE Gas line recently installed over culvert pipe at 22" depth with concrete cap. x ,,, / 1 53 City of Tukwila — Centurylink N.005074 permit request @ 4601 S 134th PI Existing PSE Gas line recently installed over culvert pipe at 22" depth with concrete cap. 18" Steel culvert pipe. Bore 140' from existing 264TA HH to driveway access pit 5'x 5'. Existing 264TA hand hole vault in soil shoulder. t / 4601 S 134TH PL BORE CROSSING / BORE TO VAULT Property of CENTURYLINK Project # N. 005074. C. 04 5411 Kathy Hubbard Traffic Control Supervisor TCS # 008909 Approved 10/6/15 Phone 253-737-5198 topndticomcast. net Celt 10585 AflNor. Kathy Ilbbard, Trak Carbd *motor Meet N 005374. C 04 C8t1rTCStCORM CIATURYIRIX:TfisPbnislee Property alCENilRYUNK LOC:5411 Camne& Oarn#ReairomMs 1.AlMrs and sparing b coRnmb Bn MOND and CdyelTUMILA 2Chantey daaoasare 28'Nair censwlhreap (elective meant 3 Alsilna are 48' x48 80 ogees *wise speafied. 4 AIM atlxted balreliefs and buttresses. Gew a remind biee ea milieus 11''alarm aidlh. &Marton s1lbe amb_ A www.invarion.com TRAFFIC CONTROL PLAN JOB # N. 005074. C. 04 PERMIT # Comments: THIS IS TO BORE 85' ACROSS S 134TH PL ONTO PRIVATE PROPERTY TO EXISTING CONDUIT. BORE 140' FROM DRIVEWAY TO 264TA HH IN SOIL SHOULDER. THIS WILL BE SHOULDER WORK. TRAFFIC FLOW ON S 134TH PL IS NOT IMPACTED. DRIVEWAYS ARE CLOSED AND TRAFFIC WILL USE OTHER DRIVEWAY ACCESSES. PFDFSTRIANS ARF NOT IMPA(TFf BORE PIT 5' X 5' INTERCEPT EXISTING CONDUIT Comments: MERGING TAPER LENGTH TAPER Cr) LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L OCT, 062015 TUKvvILI PUBLIC WORKS Az 1.15.0 Can.mentia SIGN SPACING MPH "X" 454- 500' 35 350' 30 200' 25 100' 150' SonttIo 200' s¢Eli Tw+o Comments: CHAN NE LIZATION SPA(INO M PFI TAPER TANG$ENIT 35 / 43 30' 50' 25 / 30 20' 40' ONE LANE TWO WAY CAPER 50' TO 100'maax ?tusSmi-o/5/.1 EYE C TFROM ALL fl 4e:r NORTH 0 5 10 20 30 SCALE: 1 M = 1 O' PLANTING AND STAKING DETAIL TTG•HEMLDCAVIRFUME DAWN TO REFUEAL (.14). SECURE TO TREE W. TWO STRAAC6 OF ATRSERYMAN6 BTAHE TO BE RACED PARALLEL TORREVALLAfG TAT TAT HEMLOCI4i1R STAE DRIVEN TO REFUSAL(441 SECURE TO TREF WTI NLRSERMANS TAPE STAKE E TO BEPLACED PMNR I i FREVALL*Cwta _ -iIIIn.H�II� ATIVEEOL MULCH (STING CULVERT S% SILT FENCE �� (SEE DETAIL SHEET 2 OF 3) 9 O� co 4501 BUILDING - MITIGATION PLAN NE 1/4 OF SEC. 15, TWP. 23 N, RGE. 4 E, W.M. TAX PARCEL ID NO.: 261320-0045 SPLIT RAIL FENCE DETAIL 10 ON CEMER COdRETE 'L-1 1 I I-111SI _•tt1 I_I ;Aw I— INI J—�1!11 1=` lll� +N • 1=1II_iII 1-1IHi' 4 Al 7 SILT FENCE DETAIL ETA F PEST WARE SACKED SAT FENCE AC ATT TO POSTS WITH METAL CU% CN I 11111/111111111111M111111EEI RI IN 11111111INIBSIMXIIIMENE1111 MINu �fi'IFQ M ansemissomme [E1+14I1BIi�E El�3irlyl fF' l �I�ESEOiroi em ,'� lUe Est ,glln?I4.:-:E 511.4;fiEmile:'7 it`'l10;g BUFFER GRASS SEEDING GRASS NAME SCIENTIFIC MAME BLUE WALDRYE ELYMUS CLAUCUS 60% MEADOW BARLEY HORDEUM BRACHYANTHERUM 30% TUFTED HAIRORASS DESCHAMPSIA CAESPITOSA 10% • APPLICATION RATE: 40 LBS PER ACRE • TOTAL WETLAND AREA TO BE SEEDED: 012 ACRES • TOTAL AMOUNT OF SEED NEEDED: 5 LBS • BROADF•AST SEED APPLICATION BY HAND TAffiTi PERCENTAGE IErr' EXISTING WOODY DEBRIS IN STREAM CHANNEL EXISTING CULVER' ALT FENCE METAL POUT SYMBOL STREAM SIGN DETAIL ATTACH SPA TO POST WITH 1 WO GALVANIZED VO BOLTS VATH WASHERS RET NN[ATM. 0 THE STREAM SIGN SMALL BE POSTED AT THE EOLMOMT EETWEEK THE AER TAE ARE, SUFFER SETBACK AREA LIT SETA Cat TRACT NC THE BU EOMG SETBACK AREA O CAE.. SHALL BE FPSTED PER LOT FOR EVERYISE.FEET OF...RAE MEA BUFFER ANC SMALL BE STATIONED N A MOAN.? OC.ATP HEFO •rf£STNT Ton.PORPOGED 0€ DEVELOPMENwT SCMMN AY 81ff ARPCJED TO FENCES. CEWA OR PRFSMRP TREATED FOB, SIT O INTO MOLE NOTE: STREAM SIGN MUST STATE 'ALTERATION OR DISTURBANCE IE PROHIBITED. PLEASE CALL THE CRY OF NRWLA FOR MORE INFORMATION." PLANT SCHEDULE COMMON NAME SCIENTIFIC NAME SIZE BIGLEAFMAPLE ACER MACROPHYLLU4 15 48 FT RED ALDER ALNUS RUBRA 15 -¢g�- IACC I I � J DOUGLAS FIR PSEUTOSUGA MENZIESII 10 48 FT WESTERN RED CEDAR TNUJA PUCATA 10 4-6 FT VINE MAPLE ACER CIRCINATIIM 15 3-4 FT OCEANSPRAY HOLODISCUS DISCOLOR 25 1 GAL OSOBERRY OEMLERIA CERASI FORMIS 25 1 GAL SALMONBERRY RUBUS SPECTABOJS 40 1 GAL SNOWBERRY SYMPHORICARPOS ALBUS 40 1 GAL RED -OSIER DOGWOOD CORNUS SERICIEA 20 I GAL • WESTERN SWORD FERN POLYSTICHUM MUJITUd 60 1 GAL • WOODLAND STRAWBERRY FRAGARIA VESCA 125 41NCH CUP ON -SITE STREAM CHANNEL A1i- •a1s STREAM - — -- STREAM BUFFER 0I )7,1 I20 61 R5Lr4- gIT,S Pi -vs 1-S 49ir T.-1 — - — • — • — • — REDUCED STREAM BUFFER FOR ENHANCEMENT a ate— STREAM SIGN - a a-� SPLIT RAIL FENCE eX X SILT FENCE EXISTING VEGETATION 11N6/07 LRE CITY COBA ER DATED MOPE 2 7/8N07 LRE SOOUFFER 4/18/07 LRE REVISED SITE PI NO. DATE BY REVISION Zp� 2- ® m Ili ill L. IS- 0053 4 1•01 BUILDING - MITIGATION PLAN NE 1/4 OF SEC. 15, TWP. 23 N, RGE. 4 E, W.M. TAX PARCEL ID NO.: 261320-0045 CONSTRUCTION NOTES: 1. SILT FENCE AND EXISTING TREE PROTECTION FENCE MUST BE INSTALLED PRIOR TO ANY MITIGATION ACTIVITIES TAKING PLACE 2. CLEARING OF INVASIVE VEGETATION SHALL ONLY OCCUR WRING PERIODS OF NO PERCIPITATION 3. REGRADING OF THE ENHANCEMENT AREA SHALL ONLY OCCUR DURING PERIODS OF NO PERCIPITATION 4. SILT FENCE WILL BE INSPECTED REGULARALY TO AVOID SEDIMENTATION OF STREAM CHANNEL 5. ALL AREAS CLEARED OF VEGETATION SHALL BE MULCHED TO MINIMIZE POTENTIAL EROSION 6. IF IT IS DETERMINED THAT EROSION CONTROL MEASURES HAVE FAILED, ALL MITIGATION ACTIVITIES MUST STOP UNTIL EROSION SITIITATION HAS BE RECTIFIED er; NORTH 0 15 30 80 90 SCALE: 1" = 30' VICINITY MAP NOT TO SCALE APPLIOANT. LAKERIDGE DEVELOPMENT ATTN: WAYNE JONES P.O. BOX 146 RENTON, WASHINGTON 98057 425-228-9750 CIVIL ENGINEER: DMP, INC. ATTN: MEL DALEY, P.E. 726 AUBURN WAY NORTH AUBURN, WASHINGTON 98002 253-333-2200 ENVIRONMENTAL CONSULTANT: J. S. JONES AND ASSOCIATES, INC. ATTN: JEFFERY S. JONES, PWS 402 EAST MAIN STREET, SUITE 110 AUBURN, WASHINGTON 98002 253-804-2845 ' LEGAL DESCRIPTION: 15 FOSTORIA GARDEN TRACTS BEGINNING NORTHEASTERLY CORNER OF TRACT 15 THENCE SOUTH 4017'-00" WEST 272.12 FEET THENCE NORTH 49°-43'00" VEST 92.25 FEET THENCE SOUTH 40°-17'-00' WEST 10 FEET TO THE TRUE POINT OF BEGINNING THENCE CONTINUING SOUTH 40°-1T-00" WEST TO THE NORTHERLY MARGIN OF SOUTH 135TH STREET THENCE SOUTHWESTERLY ALONG SAID NORTHERLY MARGIN TO THE WEST MARGIN OF TRACT 15 THENCE NORTHEASTERLY ALONG SAID WEST MARGIN TO NORTHWEST CORNER OF TRACT 15 THENCE SOUTH 49°-43'-00" EAST TO A POINT 175 FEET FROM NORTHEAST CORNER OF TRACT 15 THENCE SOUTH 40°-1T-00" EAST 282.12 FEET THENCE SOUTH 49°-43'-00" EAST 02.75 FEET TO TRUE POINT OF BEGINNING. SURVEY BY: D 25 WAY WC. AUBURN WASHINGTON 06002 PHONE: (253)333-2200 (GAX)333-2205 ENGINEERING - BUiIIEVIN3 LMD awuaNG LHa FND 5/8" REBAR AND CAP "BR & H LS 22336" ICEV: STREAM STREAM BUFFER REDUCED STREAM BUFFER FOR ENHANCEMENT ENHANCEMENT AREA SPLIT RAIL FENCE SILT FENCE TREE PROTECTION FENCE "Rs 4,7gC�S`� '," SILT FENCE PF' (5520ETAS5122T202:) ,,,} G EXISTING TREES} CO 00 RaGup rp REGRADED EW WNCEMENT AREA TO 15% GRADE roescm VUReeW,Or,.Ns,ORORMINO) �6's 4, SPLIT RAIL FENCE roEE OETAL 211tEET 2 OF 2f 49 7F 6-6" THUNDERCLOUD PLUM TREES 25'± 0.C. s EXISTING WOODY DEBRIS IN STREAM CHANNEL ON -SITE STREAM CHANNEL ROTEC • FENC SHEET I OF: List'.1 ]i�L TREE PROTECTION FENCE DETAIL META FF110=70E! OONSTRUGTICABA R2. M,EGT w MTH ETA ass •♦♦♦♦.♦*•♦♦**.♦*4 4• •�•�•♦�•�•�•�•4'� R: I'f&I I[ I , I I= 261n I is �11 NGTSSi TREE PROTECTION BARRIER PENCE WILL BE INSTALLED AT THE DRIPLANE OF EXISTING TREES TO REMAIN PRIOR TO GRADING. CONSULTING BIOLOGIST WILL INSPECT THE BARRIER FENCE PRIOR TO GRADING TO OETER#AINE IF THE FENCED AREA V/ILL BE ADEQUATE FOR PROTECTION OF THE ROOT ZONE. 3 11/1807 LRE C:IV COROEN DATED 19Mt 2 7/9107 LRE CO BUFFER 4/1907 LRE REVISED SITE R NO. DATE BY REVISION P.O. BOX 146 m I sw 1 i si 1 1 L I 5oo53