City of Tukwila
Allan Ekberg, Mayor
Department of Community Development - Jack Pace, Director
NOTICE OF DECISION
JANUARY 21, 2016
TO: Colin Robinson
Centerline Solutions (obo T-MOBILE)
8210 154th Avenue NE
Redmond, WA 98052
crobinson@centerlinesolutions.com
This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit
approval.
I. PROJECT INFORMATION
Project File Number: L15-0059, PL15-0051
Applicant: Colin Robinson, Centerline Solutions (obo T-MOBILE)
Type of Permit Applied for: Type 2 Wireless Telecommunications Facilities Permit
Project Description: Approval of a Type II Wireless Telecommunication Facilities
Permit to upgrade existing antennas, RRU radios, cabinet equipment, and
associated cabling on an existing non -concealed building mounted wireless
facility. No ground disturbance or expansion of the existing cabinet platform is
proposed.
Location: Tax Lot NO: 2623049021. This wireless facility is located at 16400 Southcenter
Parkway, Tukwila, WA 98188.
Associated Files: D15-0308
Comprehensive Plan
Designation/Zoning
District:
Tukwila Urban Center/ Tukwila Urban Center - Regional Center (TUC -RC)
II. DECISION
SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not
require a SEPA threshold determination because it is categorically exempt.
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
Page 2
1/21/2016
\\tukdata2k12\DCD Common$\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless NOD v2.docx
Decision on Substantive Permit: The City Community Development Department has determined that the application
for a Type 2 Wireless Communications Facility does comply with applicable City and state code requirements and has
approved that application with the following conditions:
1. Revise Note on Site Plan Sheet A3.0 to state that it is a requirement for antennas and ancillary
equipment to be painted to match the existing structure.
2. A business license is required as listed in TMC 18.58.070(2). Corresponding building permit shall not be
issued until business license is issued.
INFORMATIONAL ITEMS
1. The applicant is required to install emergency shut -down switch for Fire Department use. This can be a
condition of approval of the corresponding building permit, D15-0308. Contact the Tukwila Fire Marshal
at (206)575-4407 with any questions regarding this requirement.
III. YOUR APPEAL RIGHTS
The Decision on this Permit Application is a Type 2 decision pursuant to Tukwila Municipal Code §18.104.010.
Other land use applications related to this project may still be pending.
No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of
the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the
conditions which were imposed by the MDNS decision or the failure of the Department to impose additional
conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner.
A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King
County Superior Court from the Hearing Examiner's decision.
IV. PROCEDURES AND TIME FOR APPEALING
In order to appeal the Community Development Director decision on the Permit Application, a written notice of
appeal must be filed with the Department of Community Development within 14 days of the issuance of this
decision.
The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal materials shall
be submitted to the Department of Community Development. Appeal materials MUST include:
1. The name of the appealing party.
2. The address and phone number of the appealing party` and if the appealing party is a corporation, association
or other group, the address and phone number of a contact person authorized to receive notices on the
appealing party's behalf.
Phone: 206-433-1800 • Email: Mayor@TukwitaWA.gov • Website: TukwilaWA.gov
Page 3 `J
1/21/2016
\\tukdata2k12\DCD Common$\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless NOD v2.docx
3. A statement identifying the decision being appealed and the alleged errors in the decision, including any
specific challenge to an MDNS.
4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the
decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The
scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal.
5. Appeal fee of $602 plus retainer.
V. APPEAL HEARINGS PROCESS
Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the
Hearing Examiner based on the information presented to the Community Development Director, who made the
original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be
allowed to present oral argument based on the information presented to the Community Development Director
before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision.
Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant
to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a DNS, an MDNS or
an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in
Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS,
an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the
subject property.
VI. INSPECTION OF INFORMATION ON THE APPLICATION
Project materials including the application, any staff reports, and other studies related to the permits are available for
inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila,
Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Laura
Benjamin, who may be contacted at 206-433-7166 or via email at laura.benjamin@tukwilawa.gov for further
information.
Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact
the King County Assessor's Office for further information regarding property tax valuation changes.
Department of Community Development
City of Tukwila
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
l
• J eitq of J uPIwi&t
Department Of Community Development
AFFIDAVIT OF DISTRIBUTION
I, Laura Benjamin, HEREBY DECLARE THAT:
Notice of Application
X
Notice of Decision
Notice of Public Hearing
Notice of Public Meeting
Determination of Non-
Significance
Mitigated Determination of Non -
Significance
Short Subdivision Agenda
Determination of
Significance & Scoping
Notice
Notice of Application for
Shoreline Mgmt Permit
Shoreline Mgmt Permit
Board of Appeals Agenda
Packet
Board of Adjustment Agenda Packet
Official Notice
Notice of Action
Other:
Was mailed to each of the addresses listed/attached
on this 21 st day of January, 2016
Project Name: SE04000B Southcenter Place
Project Number: L15-0059
Associated File Number (s): PL15-0051
Mailing requested by: La ra Benjamin
Mailer's signature 1.2----___.
W:\USERS\LAURA\AFFIDAVIT OF DISTRIBUTION.DOC
Colin Robinson (Applicant)
crobinson@centerlinesolutions.com
WA State Department of Ecology - SEPA Unit
sepaunit@ecy.wa.gov
King County Assessor's Office
Accounting Division
500 Fourth Avenue, Room 709A
Seattle, WA 98104
W:\USERS\LAURA\AFFIDAVIT OF DISTRIBUTION.DOC
•7
\ i
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development— Jack Pace, Director
NOTIFICATION:
FILE NUMBER:
APPLICANT:
PROPERTY OWNER:
REQUEST:
LOCATION:
ASSOCIATED
PERMITS:
SEPA
DETERMINATION:
COMPREHENSIVE PLAN
DESIGNATION:
ZONE DESIGNATION:
STAFF:
ATTACHMENTS:
STAFF REPORT TO THE DIRECTOR
PREPARED JANUARY 21, 2016
Notification is not required for a Type II land use application.
L15-0059, PL15-0051
Colin Robinson, Centerline Solutions (obo T-MOBILE)
Legacy Partners Commercial
Approval of a Type II Wireless Telecommunication Facilities
Permit to upgrade existing antennas, RRU radios, cabinet equipment, and
associated cabling on an existing non -concealed building mounted wireless
facility. No ground disturbance or expansion of the existing cabinet platform is
proposed.
Tax Lot NO: 2623049021. This wireless facility is located at 16400 Southcenter
Parkway, Tukwila, WA 98188.
Electrical permits issued through the City of Tukwila will be required for service
alteration for any other electrical service work this is anticipated but not noted
on the plans, per article 85.13 (B), Washington electrical code. A building
permit is required for the scope of work stated on the submitted plans. Building
permit application D15-0308 received at time of this application.
Exempt
Tukwila Urban Center
Tukwila Urban Center — Regional Center (TUC -RC)
Laura Benjamin, Assistant Planner
Project Plans for Permit L15-0059
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • L4 ebsite: TukwilaWA.gov
Page 2
1/21/2016
W:\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless SR.docx
FINDINGS
Vicinity/Site Information
Project Description
The applicant is requesting approval of a Type II Wireless Telecommunication Facilities [WCF] Permit to replace
and add equipment on an existing non -concealed building mounted facility at 16400 Southcenter Parkway. The
project includes:
• Removal of 2 existing panel antennas and addition of three new panel antennas.
• Addition of 1 FRIG RRU radio.
• Addition of 1 FXFC RRU radio.
• Addition of cabinet equipment including 6 diplexers, 2 FSMF, 2 FBBC, and 1 ESMB.
The existing non -concealed building mounted cellular facility extends beyond the roofline. The proposed
modifications do not alter the existing height and is below the 85 foot maximum height without incentives in the
TUC -RC.
Existing Development
This non -concealed building mounted wireless facility is located on the Legacy Southcenter Place, an office
building located in the Southcenter (Tukwila Urban Center) area.
Surrounding Land Uses
The subject property is zoned TUC -RC. The surrounding parcels to the south and east are zoned Tukwila Urban
Center — Pond (TUC-P). The property fronts Southcenter Parkway. To the west of Southcenter Parkway, the
parcels are zoned Tukwila Urban Center — Commercial Corridor (TUC -CC). To the north, across Strander
Boulevard, the properties are also zoned TUC -RC.
BACKGROUND
In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides
specific location and design requirements for the placement of WCF within the City of Tukwila.
The WCF being modified was originally approved by the City in 1998 (L98-0016) through a conditional use
permit.
In 1998 the WCF was approved for modifications (L98-0023) through a conditional use permit. In 2008 the WCF
was approved for modifications (L08-047) through a Type 2 Wireless Facilities permit.
Location Selection
Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co -
locations and utilizing existing structures are favored over the development of new standalone WCF within the
City.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
�i
Page 3
1/21/2016
W:\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless SR.docx
TABLE A
Type of Permit Required, Based on
Type of Wireless Communication Facility
ZONING (1)
TYPE OF FACILITY
RESIDENTIAL
COMMERCIAL
INDUSTRIAL
Transmission Tower
co -location
Type 1
Type 1
Type 1
Adding antennas to an existing tower
Type 1(2)
Type 1(2)
Type 1(2)
Utility pole co -location
Type 2
Type 2
Type 2
Concealed building attached
Type 2(3)
Type 2(3)
Type 2(3)
Non -concealed building attached
Type 2
Type 2
Type 1
New tower or waiver request
Type 4
Type 4
Type 4
(1)
Zoning for any private/public property or right-of-way
Residential — LDR, MDR, or HDR
Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS
Industrial - LI, HI, MIC/L, or MIC/H
(2) Provided the height of the tower does not increase and the square footage of the enclosure area
does not increase.
(3) An applicant may request to install a non -concealed building attached facility, under TMC Section
18.58.150.
The applicant is replacing antennas and radios and installing new cabinet equipment to an existing non -
concealed building mounted wireless facility. This decision does not require the use of any new facilities for
placement of the new antennas, radios, and cabinet equipment. The proposed new cabinet equipment will be
located on an existing platform.
Design Standards
The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below
indicates if the applicant's proposal complies with required standards.
Table 1 (See TMC 18.58.070 for further details)
General Requirements
Project
does
comply
Project
does
not
comply
Not
Applicable
Notes
1. Generators or other
devices which will create
noise must comply with TMC
8.22 regarding noise.
X
The applicant has not proposed a new generator.
2.Business License
Requirement
X
T-MOBILE is in the process of applying for a business
license.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
Page 4
1/21/2016
W:\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless SR.docx
3. Only safety signage must
be placed on the WCF.
X
The applicant does not propose any signage.
4. Accommodations for
parking for maintenance
personal must be provided.
X
Parking is not affected by this modification.
5. Towers shall either
maintain a galvanized steel
finish or be painted a neutral
color so as to reduce its
visual obtrusiveness.
X
The applicant has not proposed a new tower. The
existing facility is a non -concealed building mounted
facility and does not include a tower.
6. The design of all buildings
and ancillary structures shall
use materials, colors,
textures, screening, and
landscaping that will blend
the tower facilities to the
natural setting and built
environment.
X
No new buildings or structures are proposed.
7. Antennas shall have the
same color scheme as the
structure they are located on.
X
No change to the color of the existing antennas and
equipment is proposed. The current equipment color
blends with the color of the building walls. New
antennas and radios shall be painted to match the
walls.
8. WCF poles and towers
shall only have safety lights if
required by a government
agency.
X
No lighting is proposed.
9. No advertising is
permitted on WCF
X
No advertising is proposed.
10. Each service provider
shall be limited to an
equipment enclosure of 360
square feet.
X
No change to the existing equipment enclosure is
proposed.
Table 2 (See TMC 18.58.110 for additional information)
Adding Antennas to Existing
Project
Project
Not
Notes
WCF Tower -Specific
does
does
Applicable
Development Standards
comply
not
comply
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
\_/
Page 5
1/21/2016
W:\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless SR.docx
1. The proposed facility must
meet the height
requirements of the
applicable zoning category. If
the building where the
facility is located is at or
above the maximum height
requirements, the antennas
are permitted to extend a
maximum of 3 feet above the
existing roof line.
X
No proposed changes to the height of the facility. The
facility current extends 17 feet above the roofline and is
below the 85 foot height maximum for the TUC -RC
zone.
2. Antennas shall be painted
to match the color scheme of
the building(s).
X
The antennas and radios are to be painted to match the
building walls.
3. Feed lines and cables
should be located below the
parapet of the rooftop. If the
feed lines and cables must be
visible, they must be painted
to match the color scheme of
the building(s).
X
All cables will follow existing routes along the roof top,
below the parapet.
4. If cabinet equipment
cannot be located within the
building where the wireless
communication facilities will
be located, then it must be
located on the rooftop of the
building. If screening is
required, then the proposed
screening must be consistent
with the existing building in
terms of color, style,
architectural style and
material. If the cabinet
equipment is to be located
on the ground, the
equipment must be fenced
with a 6-foot-tall fence and
materials shall be used to
screen the equipment from
view.
X
Proposed cabinet equipment will be placed on the
existing steel platform. The plans do not propose an
expansion of the existing steel platform. There are no
proposed changes to the height of the cabinet.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
Page 6
1/21/2016
W:\Users\Laura\Wireless Facilities\L15-0059\L15-0059 SC Wireless SR.docx
CONCLUSIONS
1. The proposed modifications to the existing WCF will not significantly alter the conditions that currently
exist and will not be materially detrimental to the public welfare or injurious to property or
improvements in the vicinity.
2. As demonstrated in Tables 1 and 2, the project meets all applicable development standards for a Type 2
WCF.
3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian
circulation, building or site design.
4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy
Plan.
RECOMMENDATIONS
The recommendation to the Director of Community Development is to approve this application for a Type I
Wireless Telecommunication Facility permit as applied for by Centerline Solutions for T-MOBILE with the
following conditions:
1. Revise Note on Site Plan Sheet A3.0 to state that it is a requirement for antennas and ancillary
equipment to be painted to match the existing structure.
2. A business license is required as listed in TMC 18.58.070(2). Corresponding building permit shall not be
issued until business license is issued.
INFORMATIONAL ITEMS
1. The applicant is required to install emergency shut -down switch for Fire Department use. This can be a
condition for approval of the corresponding building permit, D15-0308.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
0400
City of Tukwila
Department of Community Development
File Number
L15-0059,
PL15-0051
LAND USE PERMIT ROUTING FORM
TO: II Building Planning
❑I
Public Works I❑I Fire Dept.
Police Dept. 101 Parks/Rec
Project: SE04000B Southcenter Place
Address: 16400 Southcenter Parkway
Date
transmitted: 12/21/2015
Response
requested by: 1/11/2015
Staff
coordinator: Laura Benjamin
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
Ab uu,au4e.(4_43- of +4-1s
Plan check date: Z, _ IS
Comments
prepared by:
Update date:
0400
City of Tukwila
Department of Community Development
ECEIVF
DEC 212015
TUKVVII
PUBLIC WORKS
File Number
L15-0059,
PL15-0051
LAND USE PERMIT ROUTING FORM
TO: ID Building I❑I Planning S Public Works
ID
Fire Dept.
ID
Police Dept.
Parks/Rec
Project: SE04000B Southcenter Place
Address: 16400 Southcenter Parkway
Date
transmitted: 12/21/2015
Response
requested by: 1/11/2015
Staff
coordinator: Laura Benjamin
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed„)
have n� cmuwtet,;;9s
Plan check date:
V2-1 7:2A t
Comments
prepared by:
Update date:
0400
TO:
City of Tukwila
Department of Community Development
File Number
L15-0059,
PL15-0051
LAND USE PERMIT ROUTING FORM
Building $ Planning
Public Works
Fire Dept.
Police Dept.
Parks/Rec
Project: SE04000B Southcenter Place
Address: 16400 Southcenter Parkway
Date
transmitted: 12/21/2015
Response
requested by: 1/11/2015
Staff
coordinator: Laura Benjamin
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
Comnrert- 1,14-_-1
Plan check date:
Comments
Update date:
prepared by:
Teri Svedahl
From: Teri Svedahl
Sent: Friday, December 11, 2015 3:01 PM
To:'crobinson@centerlinesolutions.com'
Subject: SE04000B Southcenter Place Wireless Facility application
Colin —
Thank you for coming in today to submit for the Type II Wireless land use application — file # L15-
0059.
As discussed, the fee for Type II is $1760.85. This can be confirmed on the City website under
Planning Division and Land Use permits and fee schedule.
The check submitted for payment was in the amount of $620.55 — this is the fee for a Type I.
There is a balance owing of $1140.30
You can mail in the payment to my attention at the address below.
Please reference file L15-0059 to expedite processing of payment and to continue review of your
permit application.
Sincerely,
Teri, svedahl„ Adwc.%vastrative <support Teclivt,iciah,
City of Tukwila
Department of Community Development
6300 Southcenter Blvd, Ste 100
Tukwila WA 98188
Please be aware all City email is subject to public disclosure
i
`'CENTERLINE
DEC 112015
Community
Development
December 11, 2015
Department of Community Development
6300 Southcenter Blvd., #100
Tukwila, WA 98188
Re: T-Mobile Wireless Communications Facility (WCF)
T-Mobile Site Name: SE04000B South Center Place
Site Address: 16400 South Center Parkway Tukwila, WA 98188
Parcel Number: 2623049021
To Whom It May Concern:
Oh behalf of T-Mobile, Centerline Solutions is pleased to submit a Type II Zoning Application and
Building Permit Application for a modification of an existing non concealed building attached wireless
communications facility. The proposed modification consists of changes to the existing rooftop site.
The modifications will consist of the removal of 2 existing panel antennas, addition of 3 new panel
antennas, addition of 1 FRIG RRU, 1 FXFC RRU, 6 Diplexers and 2 FSMF, 2 FBBC and 1 ESMB within the
existing cabinet.
Please find enclosed:
Application Checklist
WCF Application Form
Building Permit Application Form
Construction Drawings
Structural Analysis
NIER Study
Photo Simulations
Check number 0003213286 for $620.55 and Check number 0003213285 $824.42
This modification meets the Tukwila Municipal Code §18.58 requirements for a Type II Wireless
Modification. This modification is exempt from SEPA per WAC 197-11-800 (25) (a)(i). The site does not
include any sensitive areas per NWMaps.net and all equipment is on the roof. No generator is located
at the site and none is proposed. The site is unscreened so a screening board is not applicable. The site
is on a rooftop so a landscaping plan is not applicable. Antennas will be painted to match the building
with a neutral color. A letter from a radio frequency engineer is attached. The facility is not located
within a residential zone, it is zoned TUC.
8210 154th Avenue NE, Suite 120
Redmond, WA 98052
'CENTERLINE
18.58.070 General Requirements. The following shall apply to all wireless communication facilities
regardless of the type of facility:
1. Noise — Any facility that requires a generator or other device which will create noise must
demonstrate compliance with TMC Chapter 8.22, "Noise". A noise report, prepared by an acoustical
engineer, shall be submitted with any application to construct and operate a wireless communication
facility that will have a generator or similar device. The City may require that the report be reviewed by
a third party expert at the expense of the applicant.
Applicant Response: This site does not include a generator and none is proposed.
2. Business license requirement — Any person, corporation or entity that operates a wireless
communication facility within the City shall have a valid business license issued annually by the City. Any
person, corporation or other business entity which owns a tower also is required to obtain a business
license on an annual basis.
Applicant Response: A business license application is pending.
3. Signage — Only safety signs or those mandated by other government entities may be located on
wireless communication facilities. No other types of signs are permitted on wireless communication
facilities.
Applicant Response: Acknowledged. Only signs mandated by government entities will be located on
the WCF.
4. Parking — Any application must demonstrate that there is sufficient space for temporary parking for
regular maintenance of the proposed facility.
Applicant Response: The site is located on top of an office building surrounded by ample parking.
5. Finish — A tower shall either maintain a galvanized steel finish or, subject to any applicable standards
of the FAA or FCC, be painted a neutral color so as to reduce its visual obtrusiveness. TITLE 18 — ZONING
Produced by the City of Tukwila, City Clerk's Office Page 18-217
Applicant Response: Not applicable — this is a building mounted facility rather than a tower mounted
facility. Antennas will be painted with a neutral color.
6. Design —The design of all buildings and ancillary structures shall use materials, colors, textures,
screening and landscaping that will blend the tower facilities with the natural setting and built
environment.
Applicant Response: Antennas will be painted to match the existing building. No new building
proposed.
8210 154th Avenue NE, Suite 120
Redmond, WA 98052
CENTERLINE
7. Color — All antennas and ancillary facilities located on buildings or structures other than towers shall
be of a neutral color that is identical to or closely compatible with the color of the supporting structure
so as to make the antenna and ancillary facilities as visually unobtrusive as possible.
Applicant Response: Antennas will be painted to match the building in a neutral color.
8. Lighting — Towers shall not be artificially lighted unless required by the FAA, FCC or other applicable
authority. If lighting is required, the reviewing authority shall review the lighting alternatives and
approve the design that would cause the least disturbance to the surrounding areas. No strobe lighting
of any type is permitted on any tower.
Applicant Response: No lighting is proposed or required by the FAA or FCC.
9. Advertising — No advertising is permitted at wireless communication facility sites or on any ancillary
structure or facilities equipment compound.
Applicant Response: There is no existing or proposed advertising.
10. Equipment Enclosure — Each applicant shall be limited to an equipment enclosure of 360 square feet
at each site. However, this restriction shall not apply to enclosures located within an existing
commercial, industrial, residential or institutional building.
Applicant Response: The equipment is on the roof of a building, there is no Equipment Enclosure.
18.58.110 Non -concealed Building Mounted Development Requirements. The following requirements
shall apply:
1. Height — The proposed facility must meet the height requirements of the applicable zoning category.
If the building where the facility is located is at or above the maximum height requiirements, the
antennas are permitted to extend a maximum of 3 feet above the existing roof line. Non -concealed
building mounted facilities shall not qualify as "Rooftop Appurtenances" under TMC 18.50.080.
Applicant Response: The existing facility meets the 85' TUC -RC height limit and no height increase is
proposed.
2. Antenna aesthetics — The first preference for any proposed facility is to utilize flush -mounted
antennas. Nonflushmounted antennas may be used when their visual impact will be negated by the
scale of the antennas to the building. "Shrouds" are not required unless they provide a better visual
appearance than exposed antennas. Antennas shall be painted to match the color scheme of the
building(s).
Applicant Response: The antennas will be painted to match the color scheme of the building. Please
see attached photo sims.
8210 154th Avenue NE, Suite 120
Redmond, WA 98052
'CENTERLINE
3. Feed lines and coaxial cables — Feed lines and cables should be located below the parapet of the
rooftop. If the feed lines and cables must be visible, they must be painted to match the color scheme of
the building(s).
Applicant Response: All cables will be located below the parapet of the rooftop.
4. Cabinet equipment — If cabinet equipment cannot be located within the building where the wireless
communication facilities will be located, then it must be located on the rooftop of the building. If the
equipment can be screened by placing the equipment below the parapet walls, no additional screening
is required. If screening is required, then the proposed screening must be consistent with the existing
building in terms of color, style, architectural style and material. If the cabinet equipment is to be
located on the ground, the equipment must be fenced with a 6-foot-tall fence and materials shall be
used to screen the equipment from view. Barbed wire may be used in the TVS, LI, HI, MIC/L, and MIC/H
zones. (Ord. 2135 §1 (part), 2006)
Applicant Response: The cabinets are located on the rooftop of the building. No new cabinets are
proposed. Please see the attached photo simulations.
If you have any questions or inquiries regarding this application please feel free to contact me.
Thank you,
Colin Robinson
Zoning Specialist
8210 154th Avenue NE, Suite 120
Redmond, WA 98052
8210 154th Avenue NE, Suite 120
Redmond, WA 98052
P C99VF
DEC 1I �01�
E T E R L I N E Community
Development
RF Safety and NIER Analysis Report
RECEE WF",
12/08/2015 DEC 212015
TUKVvtu-,
Site: SE04000B PUBLIC WORKS
Prepared for: T-Mobile
Prepared for: T-Mobile, Site: SE04000B
Table of Contents
Certification 3
Executive Summary 4
Introduction 6
Site Details 6
Predictive Analysis Details 9
Conclusions and Recommendations 13
Appendix A: FCC Compliance and RF Safety Policies 14
Appendix B: Overview of RoofView® Functions and Assumptions 16
References 18
Limited Warranty 18
Centerline Solutions, Inc. Proprietary and Confidential Page 2 of 18
Prepared for: T-Mobile, Site: SE04000B
Certification
This report, prepared by Centerline Solutions, LLC for T-Mobile, is intended to
document compliance and evaluate power density levels as outlined in the report. The
computations, analysis, and resulting report and conclusions were based on applicable
FCC guidelines and regulations for maximum permissible exposure to humans consistent
with FCC OET Bulletin 65, Edition 97-01.
Additionally, Centerline Solutions, LLC certifies that the assumptions are valid and that
the data used within Centerline Solutions' control are accurate, including information
collected as part of Centerline Solutions' field surveys. Centerline Solutions, LLC does
not however certify the accuracy or correctness of any data provided to Centerline
Solutions, LLC for this analysis and report by T-Mobile or other third parties working on
behalf of T-Mobile.
I certify that the attached RF exposure analysis and report is correct to the best of my
knowledge, and all calculations, assumptions and conclusions are based on generally
acceptable engineering practices:
EXPIRES 2/22/2016
Patrick A. Kearns, P.E.
12/08/2015
Centerline Solutions, Inc. Proprietary and Confidential Page 3 of 18
Prepared for: T-Mobile, Site: SE04000B
Executive Summary
This report provides the results of an RF power density analysis performed for T-Mobile
at Site SE04000B.
Current Site Configuration:
Three sector site operating with technology including GSM in PCS band (1900 MHz),
UMTS in PCS (1900 MHz band), UMTS in AWS (2100 MHz), LTE in AWS band (2100
MHz), and LTE in the 700 MHz band.
Proposed Site Configuration:
Modification in the current Gamma sector configuration and applying a sector split. Four
sector site operating with technology including GSM in PCS band (1900 MHz), UMTS in
PCS (1900 MHz band), UMTS in AWS (2100 MHz), LTE in AWS band (2100 MHz),
and LTE in the 700 MHz band.
Scope of Work:
The proposed physical modifications will result in replacing antennas and radio hardware
at this site.
Rooftop Equipment Modifications:
• Removal of (3) existing panel antennas
• Addition of (3) panel antennas
• Addition of (1) FRIG
• Addition of (1) FXFC
• Addition of (8) Diplexer
• Addition of (2) FSMF (2) FBBC, & (1) ESMB in (E) cabinet
Site Description:
• Site Type and Height- Rooftop, elevation of 73.0 ft. AGL
• Equipment Location- Adjacent to the antennas.
• Other Antennas- There are 8 Verizon antennas and a microwave dish. Also, there
are several satellite dishes.
• Access- The only access to the site is through the locked door leading to the
rooftop.
• Study Reference Location- This study examines the power density environment at
ground, rooftop, and penthouse levels from ALL sources of RF radiation, except
for those antennas specifically excluded as described in the Introduction section.
• Existing Signage- There are blue RF signs and a yellow RF guideline sign placed
at the interior side of the door that leads to the rooftop of the building. Also, there
are barriers with blue Notice signs around Verizon's antennas.
Centerline Solutions, Inc. Proprietary and Confidential Page 4 of 18
Prepared for: T-Mobile, Site: SE04000B
• RF Environment- For purposes of evaluating compliance with FCC OET Bulletin
65, the area on the ground level is considered to be an uncontrolled/public
environment. However, the areas on the rooftop and penthouse levels are
considered to be controlled/occupational environments.
Analysis:
The analysis of the RF power density at this site indicates that emissions on the ground
will not exceed the FCC's MPE limit for General Public environments. T-Mobile's
contribution to the rooftop level exposures is calculated to be less than 28.2% of the FCC
MPE limit for Occupational/Controlled environments. The rooftop level exposures near
Verizon's Beta sector antennas are calculated to be less than 122.9% of the FCC MPE
limit for Occupational/Controlled environments. However, Verizon has mitigated the
risk of accidental exposure by placing barriers and RF signs.
Conclusion and Recommendations:
• The results of the analysis indicate that the power density levels at the ground will not
exceed the FCC MPE General Population limit with the proposed antenna plan.
• The results of the analysis indicate that the power density levels on the main building
rooftop contributed by T-Mobile will not exceed the FCC MPE Occupational limit with
the proposed antenna plan.
• The results of the analysis indicate that the power density levels on the north penthouse
(Penthouse 2) may exceed the FCC MPE Occupational limit with the proposed antenna
plan. However, Penthouse 2 is not generally accessible.
• Centerline Solutions recommends placing blue RF signs on the wall of the south
penthouse (Penthouse 1), adjacent to the antennas of the Gamma sector. In
addition, Centerline Solutions recommends placing yellow RF signs near the top of
the roof and on each side of the north penthouse (Penthouse 2). See Exhibits 5 and 6
for recommended signage locations.
• By taking the above mentioned recommended actions, this site will operate in general
compliance with the FCC's OET Bulletin 65.
Centerline Solutions, Inc. Proprietary and Confidential Page 5 of 18
Prepared for: T-Mobile, Site: SE04000B
Introduction
The purpose of this analysis and report is to evaluate the cumulative power density levels
of all antennas located on the building rooftop and identify any areas of concern that
require mitigation. This report also assesses the rooftop's compliance with FCC OET
Bulletin 65; "Guidelines for Human Exposure to Radio -frequency Electromagnetic
Fields".
As part of this analysis, the site was visited on 11/17/2015 to perform a complete field
survey. The purpose of the survey was to verify antennas located on the building rooftop
and identify co -located wireless facilities.
The power density simulation performed for this site utilized RoofView® analysis
software. All antennas were assigned an operating frequency and transmit power and
were deemed to be operating at 100% of their rated output power. The microwave dish
antenna located on Verizon's Alpha sector and other satellite dishes were not included in
the analysis, as their beamwidth is very narrow, and very little of their radiated energy is
propagated to the rooftop level below the antenna.
Site Details
Address: 16400 South Center Park Way
Tukwila, WA 98188
Site type: Building
Height: — 73.0 ft. AGL
The photographs on the following pages show a view of the existing antennas on the
rooftop and RF signage that is present.
Centerline Solutions, Inc. Proprietary and Confidential Page 6 of 18
Prepared for: T-Mobile, Site: SE04000B
r
, •
i or
I'JORMATlQN
ROOF ACCESS
Exhibit 1- Photos
Centerline Solutions, Inc. Proprietary and Confidential
Page 7 of 18
Prepared for: T-Mobile, Site: SE04000B
Exhibit 2- Photos (Verizon's sectors)
Centerline Solutions, Inc. Proprietary and Confidential Page 8 of 18
Prepared for: T-Mobile, Site: SE04000B
Antenna Inventory:
The following table contains the technical data used to simulate the power density that
may be encountered with all antennas simultaneously operating at full rated power.
D
Name
(MHz)
Freq
Trans
Power
Trans
Count
Other
Loss
Calc
Power
Mfg
Model
(ft)
Z(Ground)
(ft)
Z(Rooftop)
(ft)
Z(Penthouse)
Type
(ft)
Aper
dad
Gan
BWdth
Ptt3r
TMA1A
L2100
2150.00000
120.0
1
0.5
107.0
Comrficope
TMBXX-6516-R2M
76.4
13.6
3.4
DBQuad
4.9
15.35
65;130
TMA2A
G1900
1950.00000
20.0
2
0.5
35.7
ComrScope
SBNFI1-+1D65B
75.2
12.4
2.2
Hexport
6.1
16.05
66;130
TMA2B
U1900
1950.00000
30.0
2
0.5
53.5
ConrrScope
SBNI#1D65B
752
12.4
2.2
Hexport
6.1
16.05
66;130
TMA2C
U2100
2150.00000
40.0
1
2.0
25.2
ConrrScope
SBNF I-1D65B
75.2
12.4
2.2
Hexport
6.1
16.45
63;130
TMA2D
L700
730.00000
40.0
1
0.5
35.7
CormScope
SBNI#1D65B
75.2
12.4
2.2
Hexport
6.1
12.75
68;130
TMB1A
L2100
2150.00000
120.0
1
0.5
107.0
ComrScope
TMBXX-6516-R2M
76.4
13.6
3.4
DBQuad
4.9
15.35
65;220
TMB2A
G1900
1950.00000
20.0
2
0.5
35.7
CorrrScope
SBNI1+10658
75.2
12.4
2.2
Hexport
6.1
16.05
66;220
TMB2B
U1900
1950.00000
30.0
2
0.5
53.5
Conrr6cope
SBNI-A+1D65B
75.2
12.4
2.2
Hexport
6.1
16.05
66;220
TMB2C
U2100
2150.00000
40.0
1
2.0
25.2
ComrScope
SBNH-1D65B
75.2
12.4
2.2
Hexport
6.1
16.45
63;220
TMB2D
L700
730.00000
60.0
1
0.5
53.5
ComrScope
SBNI#1D65B
75.2
12.4
2.2
Hexport
6.1
12.75
68;220
TMC1A
G1900
1950.00000
20.0
2
0.5
35.7
ComnScope
1-13XX-3319DS-A2M
76.6
13.8
3.6
Quad
4.8
18.45
35;310
TMC1B
U1900
1950.00000
30.0
2
0.5
53.5
CormScope
1-13XX-3319DS-A2M
76.6
13.8
3.6
Quad
4.8
18.45
35;310
TMC1C
12100
2150.00000
120.0
1
0.5
107.0
Corrr6cope
I-BXX-33191:6-A2M
76.6
13.8
3.6
Quad
4.8
18.65
34;310
TMC2A
U2100
2150.00000
40.0
1
2.0
252
ComrScope
DBXNH-6565E-A2M
75.2
12.4
2.2
DBQuad
6.1
16.05
63;340
TMC2B
L700
730.00000
60.0
1
0.5
53.5
ConanScope
DBXNH-6565E-A2M
75.2
12.4
2.2
DBQuad
6.1
13.05
71;340
TMD1A
G1900
1950.00000
20.0
2
0.5
35.7
ComrScope
FBXX-3319DS•A2M
76.6
13.8
3.6
Quad
4.8
18.45
35;20
TMO1B
U1900
1950.00000
30.0
2
0.5
53.5
ComrScope
FBXX-3319D5-A2M
76.6
13.8
3.6
Quad
4.8
18.45
35;20
TMD1C
L2100
2150.00000
120.0
1
0.5
107.0
Corm$cope
FBXX-3319DS-A2M
76.6
13.8
3.6
Quad
4.8
18.65
34;20
VZA1A
L700
730
60
1
2.0
37.86
Anphenol
BXA-70063-8CF®N
67.1
4.3
-5.9
X-Pole
7.89
15.45
65;15
VZA4A
C850
850
20
8
2.0
101
Arrphenol
BXA-70063-8CF®N
67.6
4.8
-5.4
X-Pole
7.89
15.45
65;15
VZA2A
L2100
2150
60
2
0.5
107
Anphenol
CWWX063X19x00
69.3
6.5
-3.8
X-Pole
6.25
14.85
67;15
VZA3A
C1900
1950
16
3
3.0
24.06
Arrphenol
CWWX063X19x00
69.3
6.5
-3.8
X-Pole
6.25
15.05
66;15
VZB1A
C850
850
20
8
2.0
101
Arrphenol
BXA-70063-8CF®1N
67.1
4.3
-5.9
X-Pole
7.89
15.45
65;190
VZB4A
L700
730
60
1
2.0
37.86
Arrphenol
BXA-70063-8CFB7N
67.6
4.8
-5.4
X-Pole
7.89
15.45
65;190
VZB2A
C1900
1950
16
3
3.0
24.06
Anphenol
CWWX063X19x00
69.3
6.5
-3.8
X-Pole
6.25
14.85
67;190
VZB3A
L2100
2150
60
2
0.5
107
Arrphenol
CWWX063X19x00
69.3
6.5
-3.8
X-Pole
6.25
15.05
66;190
Exhibit 3- Antenna Details
Predictive Analysis Details
For purposes of this analysis, RoofView® was configured to provide an output based on
the appropriate MPE limit(s) published in the FCC's guidelines. The antenna
information was loaded into RoofView®, an MPE predictive analysis tool by Richard
Tell and Associates, Inc. The analysis was run for the ground, building rooftop, and
penthouse levels.
The following exhibits show the calculated RF emissions at these levels. Exhibit 4 shows
the RF emissions at ground level, Exhibit 5 shows the RF emissions at the rooftop level,
and Exhibit 6 shows the RF emissions at the penthouse level. The solid green shading
indicates that power density levels are expected to be less than 5% of the applicable MPE
level in these areas. Other colors are defined in the legends below.
Centerline Solutions, Inc. Proprietary and Confidential Page 9 of 18
Prepared for: T-Mobile, Site: SE04000B
Ground
Ground Level
•
rruund
Greer; <= 5% General Population Limit Blue <= 20% General Population Limit
<= 100% General Population Limit Red > 100% General Population Limit
Exhibit 4- % MPE General Population
Ground Level
(Not to scale)
Page 10 of 18
Prepared for: T-Mobile, Site: SE04000B
North Verizon
Rooftop
Rooftop Level
Green <= 5% Occupational Limit Blue <= 20% Occupational Limit
<= 100% Occupational Limit Red > 100% Occupational Limit
Exhibit 5- % MPE Occupational
Building Rooftop Level
(Not to scale)
Page 11 of 18
Prepared for: T-Mobile, Site: SE04000B
Grourd
Penthouse Level
f;reeu <= 5% Occupational Limit Blue <= 20% Occupational Limit
<= 100% Occupational Limit Red > 100% Occupational Limit
Exhibit 6- % MPE Occupational
Penthouse Level
(Not to scale)
Page 12 of 18
Prepared for: T-Mobile, Site: SE04000B
Conclusions and Recommendations
• The results of the analysis indicate that the power density levels at the ground will not
exceed the FCC MPE General Population limit with the proposed antenna plan.
• The results of the analysis indicate that the power density levels on the main building
rooftop contributed by T-Mobile will not exceed the FCC MPE Occupational limit with
the proposed antenna plan.
• The results of the analysis indicate that the power density levels on the north penthouse
(Penthouse 2) may exceed the FCC MPE Occupational limit with the proposed antenna
plan. However, Penthouse 2 is not generally accessible.
• Centerline Solutions recommends placing blue RF signs on the wall of the south
penthouse (Penthouse 1), adjacent to the antennas of the Gamma sector. In
addition, Centerline Solutions recommends placing yellow RF signs near the top of
the roof and on each side of the north penthouse (Penthouse 2). See Exhibits 5 and 6
for recommended signage locations.
• By taking the above mentioned recommended actions, this site will operate in general
compliance with the FCC's OET Bulletin 65.
Note: Modifications to the site; and/or increases in channel counts or power levels exceeding those listed
in this report will require additional evaluation to determine compliance.
Page 13 of 18
Prepared for: T-Mobile, Site: SE04000B
Appendix A: FCC Compliance and RF Safety Policies
In August of 1997, the FCC published OET Bulletin 65 Edition 97-01 to regulate
methods for evaluating compliance with FCC guidelines for human exposure to
radiofrequency (RF) electromagnetic fields. The FCC guidelines for human exposure to
RF electromagnetic fields incorporate two categories of limits; namely "Controlled"
(a.k.a. Occupational) and "Uncontrolled" (a.k.a. General Public). The guidelines offer
suggested methods for evaluating fixed RF transmitters to insure that the controlled and
uncontrolled limits deemed safe by the FC for human exposure are not exceeded.
OET Bulletin 65 recommended guidelines are intended to allow an applicant to "make a
reasonably quick determination as to whether a proposed facility is in compliance with
the limits." In addition, the guidelines offer alternate supplementary considerations and
procedures such as field measurements and more detailed analysis that should be used for
multiple emitter situations.
These guidelines define RF as emissions in the frequency range of 300 kHz to 100 GHz.
The FCC define Maximum Permissible Exposure (MPE) limits within this frequency
range based on limits recommended by the National Council on Radiation Protection and
Measurement, the Institute of Electrical and Electronics Engineers (IEEE), and by the
American National Standards Institute (ANSI).
The specific MPE limits defined by the FCC are as follows:
Frequency
Range [MHz]
0.3 - 3.0
3.0 - 30
30 - 300
300 -1,500
1,500 - 100,000
Limits for Occupational/Controlled Exposure
Electric Field
Strength (E) [V/m]
614
1842/f
61.4
Magnetic Field
Strength (H) [A/m]
1.63
4.89/f
0.163
Power Density
(S) [mW/Cm"2]
100*
900/f^2*
1
f/300
5
Averaging Time IEI"2,
CHI"2 or S [minutes]
6
6
6
6
6
Frequency
Range [MHz]
0.3 - 3.0
3.0 - 30
30 - 300
300 -1,500
1,500 -100,000
Electric Field
Strength (E) [V/m]
614
842/f
27.5
Limits for General Population/Uncontrolled Exposure
Magnetic Field Power Density Averaging Time IEI"2,
Strength (H) [Alm] (S) [mW/Cm"2] IHI"2 or S [minutes]
1.63 100* 30
2.19/f 180/f^2* 30
0.073 0.2 30
f/1500 30
1 30
f = frequency
*Plane -wave equivalent power density
The FCC states that "Occupational/Controlled limits apply in situations in which persons
are exposed as a consequence of their employment provided those persons are fully
aware of the potential for exposure and can exercise control over their exposure. Limits
for Occupational/Controlled exposure also apply in situations when an individual is
transient through a location where Occupational/Controlled limits apply provided he or
she is made aware of the potential for exposure."
Page 14 of 18
Prepared for: T-Mobile, Site: SE04000B
For General Population/Uncontrolled limits, the FCC states that "General Population/
Uncontrolled exposures apply in situations in which the general public may be exposed,
or in which persons that are exposed as a consequence of their employment may not fully
be aware of the potential for exposure or cannot exercise control over their expos ire."
For purposes of this analysis, all limits are evaluated against the Power Density limits.
Typical guidelines for determining whether Occupational/Controlled limits can be
applied include insuring the environment (such as a rooftop) as limited/controlled access
via locked doors or physical barrier that are preferably controlled by a landlord that is
aware of the situation and can inform anyone going through the locked door of the
existence of the RF emissions. Such notification/awareness is typically accomplished by
means of signage on the door, or other access to the area of concern, as well as signage
on or near the antennas. Examples of such signs include the following:
re.V c
•
Radio frequency tetds beyond
this point may exceed the FCC
genera/ public exposure limit.
Obey an posted signs and site guidelines
fin wetting In radio rntquency
environments.
CAUTION
Beyond this point:
Radio frequency fields at this site
nay exceed FCC rules for human
exposure.
Fos your safety, obey ax posted signs and
site guidelines for working in radio
frequency environments.
•
Beyond this point
Radio frequency fields at this site
exceed the FCC rutes for human
exposure.
Failure lo obey ali posted signs and sae
grrid.anes far working In radio frequency
environments could result in serious Mrtuty.
Standards for when to use each of the above signs for Occupational situations are as
follows:
No sign required: <20% of Occupational MPE
Blue Sign, Notice: 20% to <100% of MPE
Yellow Sign, Caution: 100% to <1000% of MPE
Red Sign, Warning: >1000% of MPE
All MPE references are to the FCC Occupational limits.
Page 15 of 18
Prepared for: T-Mobile, Site: SE04000B
Appendix B: Overview of RoofView® Functions and
Assumptions
RoofView® is a tool developed and supported by Richard Tell Associates, Inc. to be
used for analysis of RF field levels at telecommunications sites produced by antennas of
the type commonly used in cellular, paging, SMR, PCS and two-way radio
communications services. Although its name suggests that the tool is only for use in
evaluating emissions for roof top applications, it can also be used to evaluate ground
level effects of tower facilities.
RoofView® allows the user to apply near field, far field, or a combination of near and far
field computational methods as desired by the user. For this analysis, near field
computations are used for areas within the near field, and far field computations are used
beyond the near field. Specific break points are dynamic based on the aperture of the
antenna being analyzed.
The near field methodology is based on a cylindrical model that assumes the power into
an antenna is distributed as a cylinder around the aperture of the antenna. Research by
Richard Tell Associates, Inc. found that using such a model, along with corrections for
height and antenna pattern, is very accurate, if not slightly conservative in estimating RF
exposure. FCC Bulletin 65 recognizes the use of the cylindrical model for near field
calculations. The following picture and corresponding equation summarizes the
computations used by RoofView® on a bin -by -bin basis when the near field method is
used:
S= 360P
0 BW 2nRh
3 dB Beam
(degrees) - eBW
Each bin's results are then also adjusted by spatially averaging the portion of a 6 foot tall
human that intercepts the aperture over 6 feet. Once the antenna is completely above (or
below) the height that corresponds to a 6 foot tall human, the cylindrical results are
Page 16 of 18
Prepared for: T-Mobile, Site: SE04000B
reduced to 10% of their results and then dissipated inversely in proportion to the square
of the distance.
Once bins being analyzed fall outside of the near field (as determined by a method and
variable that is user -selectable; see below for method and variable used in this analysis), a
far -field spatial average is calculated. Spatially averaged power density in the far -field is
calculated by reducing the spatially averaged power density inversely, by the square of
the distance from the antenna(s).
There are several input variables to RoofView® that can impact the results produced
when evaluating specific cell sites. Those variables are summarized accordingly:
Required Inputs for RoofView® v4.15 Analysis
Thresholds
>= 0%
>= 5%
>= 20%
>= 100%
'Blue
Yellow
(Relative to Controlled Limits)
Green < 5%
< 20%
< 100%
Standard
FCC 1997 Occupational (default)
FCC 1997 General Population (as applicable)
Model
Near/Far Spatial Average
Uptime
100% (vary as applicable)
Near/Far Field Transition Method
X ApHt
Near/Far Field Transition At Ht Factor
1.5
Page 17 of 18
Prepared for: T-Mobile, Site: SE04000B
References
FCC (1997). "Evaluating Compliance with FCC Guidelines for Human Exposure to
Radiofrequency Electromagnetic Fields"; Federal Communications Commission; Office
of Engineering and Technology, OET Bulletin 65, Edition 97-01, August.
Richard Tell Associates, Inc. (2003). RoofView® User Guide Version 4.15, Richard
Tell Associates, Inc., February 10, 2003.
Limited Warranty
Centerline Solutions, LLC warrants that this analysis was performed in good faith using
the methodologies and assumptions covered in this report and that data used for the
analysis and report were obtained by Centerline Solutions, LLC employees or
representatives via site surveys or research of T-Mobile's available information. In the
event that specific third party details were not available, best efforts were made to use
assumptions that are based on industry experience of various carriers' standards without
violating any confidential information obtained under non -disclosure terms.
Centerline Solutions, LLC also warrants that this analysis was performed in accordance
with industry acceptable standards and methods.
There are no other warranties, express or implied, including but not limited to, the
implied warranties of merchantability and fitness for a particular purpose, relating to this
agreement or to the services rendered by Centerline Solutions hereunder. In no event
shall Centerline Solutions be held liable to T-Mobile, or to any third party, for any
indirect, special, incidental, or consequential damages, including but not limited to loss of
profits, loss of data, loss of good will, and increased expenses. In no event shall
Centerline Solutions be liable to T-Mobile for damages, whether based in contract, tort,
negligence, strict liability, or otherwise, exceeding the amount payable hereunder for the
services giving rise to such liability.
Page 18 of 18
•
/ \
._ �
COMPLETE APPLICATION CHECKLIST
The materials listed below must be submitted with your application unless specifically waived in writing the Department of
Community Development. Please contact each Department if you feel that certain items are not applicable to your project and
should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS
MAY BE REQUIRED.
The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require
additional information as needed to establish consistency with development standards.
City staff are available to answer questions about application materials at 206-431-3670 (Department of Community
Development) and 206-433-0179 (Department of Public Works).
Check items
submitted
with
application
Information Required. May be waived in unusual cases, upon approval of both Public Works and
Planning
APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities.
1
1. Application Checklist (1 copy) indicating items submitted with application.
✓
2. Completed Application Form and drawings (5 copies).
✓
3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site
map, architectural elevations, method of attachment, proposed screening, location of proposed antennas,
and all other information which accurately depicts the proposed project. Minimum size
is 8 1/2" x 11". Plans shall be no greater than 24" x 36".
1
4. Application Fee: See Land Use Fee Schedule.
1
5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property
(1 copy attached).
6. SEPA Environmental Checklist. SEPA is not required when the facility:
i) Is a microcell and is to be attached to an existing structure that is not a residence or school and
does not contain a residence or a school;
ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing
structure (that may be an existing tower) that is not a residence or school and does not contain a
residence or school, and the existing structure to which it is to be attached is located in a
commercial, industrial, manufacturing, forest or agriculture zone; or
iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a
commercial, industrial, manufacturing, forest, or agricultural zone.
1
7. A letter from the applicant describing the proposed project and describing compliance with the
City's Code requirements.
8. Sensitive Area studies and proposed mitigation (if required).
9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating
compliance with TMC Chapter 8.22, "Noise".
If the application requires a Type 2 review these additional items are needed:
1
10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility;
11. Materials board for the screening material;
12. Landscaping plan;
1
13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal
requirements for allowed emissions;
14. If the facility is located within a residential zone, a report from a radio frequency engineer
explaining the need for the proposed wireless communication facility at that location. Additionally, the
applicant shall provide detailed discussion on why the wireless communication facility cannot be located
within a commercial or industrial zone.
\\deptstore\City Common\Teri\Revisions In Progress\Wreless Communication Facility-Jan2011.docx
•
Check items
submitted
with
application
Information Required. May be waived in unusual cases, upon approval of both Public Works and
Planning
If the application requires a Type 3 review these additional items are needed:
15. A narrative responding to the criteria at TMC Section 18.58.060.
16. The radio frequency engineer report shall include a discussion of the information required under
TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of the
other location options outlined in Table A.
17. Engineering Plans for the proposed tower.
18. A vicinity map depicting the proposed extent of the service area.
19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and
ancillary facilities from five points within the impacted vicinity. Such points are to be mutually agreed
upon by the Director of DCD and applicant. All plans and photo simulations shall include the maximum
build -out of the proposed facility.
20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and
lighting and certificates of compliance from all affected agencies.
21. Evidence that the tower has been designed to meet the minimum structural standards for wireless
communication facilities for a minimum of three providers of voice, video or data transmission services,
including the applicant, and including a description of the number and types of antennas the tower can
accommodate.
PUBLIC NOTICE MATERIALS:
22. Payment of notice board fee (see Land Use Fee schedule) to FastSigns Tukwila OR provide a 4' x 4'
public notice board on site within 14 days of the Department determining that a complete application has
been received (see Public Notice Sign Specifications Handout).
23. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; OR provide an
excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses) within
500 feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos, trailer
parks --must be included.
Once your project is assigned to a planner, you will be required to provide an electronic copy of the mailing
label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these fields as an
individual column:
Name
Street Address
City, St, Zip
Mr. Smith
1234 Park Ave S
Tukwila WA 98188
PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you provide
them, there is an additional fee for postage and material as listed under Public Notice Mailing Fee on
the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the decision and you will
receive a separate bill for this fee.
24. If providing own labels, include King County Assessor's map(s) which shows the location of each
property within 500 ft. of the subject lot.
\\deptstore\City Common\Teri\Revisions In Progress\Wireless Communication Facility-Jan2011.docx
r
SE04000B South Center Place
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670
AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS
PERMISSION TO ENTER PROPERTY
STATE OF WASHINGTON
-Gc.sJ ipty
DEC 112015
Community
Development
ss
COUNTY OF KING
The undersigned being duly sworn and upon oath states as follows:
1. I am the current owner of the property which is the subject of this application.
2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my
knowledge.
3. The application is being submitted with my knowledge and consent.
4. Owner grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real
property, located at 16400 Southcenter Parkway Tukwila, WA 98188 for the purpose of application
review, for the limited time necessary to complete that purpose.
5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during
the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City.
6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without
refund of fees.
EXECUTED at Itt e vC.c Flo..{ (city), jf/`4- (state), on D rn11,c. 1 C] , 20 15
tc,kcA 5 3 12ccd��ccf
(Print Name)
(Address)
2$3S 8"2 .1 /Jtv-t 5
2GC, 2Ce (ao(Qo
(Phone Number)
(Signature) 7//K
`-_—� ✓l
On this day personally appeared before me i c hc.)1(1`) ,T to me known to be the individual who
executed the foregoing instrument and acknowledged that he/she signed the same as his/her voluntary act and deed for the uses and
purposes mentioned therein.
SUBSCRIBED AND Sl�(t t114IT(ft FORE ME ON THIS [Li DAY OF MCC Of f , 20 4'j
43/65 F-ta\o s NOTARY UB IC in and r the Sta f Washington otc+'ac-) _,', jet —
NOTARY' 1 = residing at incip e idle' 1 tvA
it zi
N .5 PUBLIC, /,
9'•!�E 12 2z°b>"
dcptstorelCity Common\Ter \Revtbfb taljjt SWtrelus Communication Facility-1an2011.docx
My Commission expires on % 1 a - 301 g'
Name:
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670
fECE VED
DEC 112015
Commnity
Developument
WIRELESS TELE-
COMMUNICATION
FACILITIES
APPLICATION
FOR STAFF USE ONLY Permits Plus Type: P-WIRE
Planner:
File Number: L l_ —/6
ei
Application Complete Date:
Project File Number: ,pL /
('y 5 f
Application Incomplete Date:
Other File Numbers:
NAME OF PROJECT/DEVELOPMENT: SE04000B South Center Place
BRIEF DESCRIPTION OF PROJECT: Modify existing wireless communications facility
CIRCLE TYPE - TYPE 1 ■ TYPE 2 TYPE 3 (PUBLIC HEARING NOTICE RQD)
LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and
subdivision, access street, and nearest intersection.
16400 South Center Pliacearkway Tukwila, WA 98108
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
2623049021
DEVELOPMENT COORDINATOR :
The individual who:
• has decision making authority on behalf of the owner/applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping development
standards, and
• is the primary contact with the City, to whom all notices and reports will be sent.
Colin Robinson Tom, T_ ,41. e
Address: 8210 154th Ave NE Redmond, WA 98052
Phone: (425) 533-2665 FAX:
E-mail: Robinson@centerlinesolutions.com
Signature: 17ry --- Date: 12 - 1, - 20,
S
\\deptstore\City Common\Teri\Revisions In Progress\Wireless Communication Facility-Jan201 l.docx
• APPROX.
PHOTO
LOCATION
%. APPROX.
PROPOSED
ANTENNA
LOCATIONS
5 iii ig j r� n(,T�;is
Existing
�C EN TER LINE
CE vE
DEC 112015
Community
Development
obi
le
SOUTH CENTER PLACE
Looking South
(N) T-MOBILE PANEL ANTENNAS.
TYP OF (1) PER SECTOR, TOTAL
OF (3), MOUNTED ON (E) WALL
PIPE MOUNTS
-SEE NOTES
Proposed 4/S..00
NOTES:
1. PM/GC TO VERIFY PAINTING REQUIREMENTS WITH JURISDICTION PRIOR TO ORDERING SUPPORT STRUCTURES,
ATTACHMENTS, ANTENNAS, AND OTHER APPURTENANCES.
2. VISUAL IMPACTS WILL BE AFFECTED BY LOCATION AND VISIBILITY OF OBSERVER. THIS DOCUMENT IS FOR
PLANNING AND INFORMATION PURPOSES ONLY AND IS CONCEPTUAL. THIS IS SOLELY THE PHOTOGRAPHER'S
INTERPRETATION OF THE PROPOSED DEVELOPMENT.
1
,ce
!► APP.
W PI�° ®, El ® \ bile
CO LOCATICDEC 112015
0PROP. EROXsEoelmomntS O U T H CENTER PLACE
o
ANTENNA
LOCATIONS
W
Existing
Looking East
(N) T-MOBILE PANEL ANTENNAS, TYP OF
(1) PER SECTOR, TOTAL OF (3),
MOUNTED ON (E) WALL PIPE MOUNTS
NOT VISIBLE FROM THIS LOCATION
-SEE NOTES
2
Proposed / /5.00.00641
NOTES:
1. PM/GC TO VERIFY PAINTING REQUIREMENTS WITH JURISDICTION PRIOR TO ORDERING SUPPORT STRUCTURES,
. ATTACHMENTS, ANTENNAS, AND OTHER APPURTENANCES.
CENTERLINE
2. VISUAL IMPACTS WILL BE AFFECTED BY LOCATION AND VISIBILITY OF OBSERVER. THIS DOCUMENT IS FOR
PLANNING AND INFORMATION PURPOSES ONLY AND IS CONCEPTUAL. THIS IS SOLELY THE PHOTOGRAPHER'S
INTERPRETATION OF THE PROPOSED DEVELOPMENT.
Existing
• APPROX.
PHOTO
LOCATION
APPROX.
PROPOSED
ANTENNA
LOCATIONS
"03
DEC 112015
Community
Development
EN TER LINi
T•
obile
SOUTH CENTER PLACE
Looking Northeast
(N) T-MOBILE PANEL ANTENNAS, TYP OF
(1) PER SECTOR, TOTAL OF (3),
MOUNTED ON (E) WALL PIPE MOUNTS
NOT VISIBLE FROM THIS LOCATION
•SEE NOTES
3
Proposed ( /se. CQ S'9
NOTES:
1. PM/GC TO VERIFY PAINTING REQUIREMENTS WITH JURISDICTION PRIOR TO ORDERING SUPPORT STRUCTURES,
ATTACHMENTS, ANTENNAS, AND OTHER APPURTENANCES.
2. VISUAL IMPACTS WILL BE AFFECTED 8Y LOCATION AND VISIBILITY OF OBSERVER. THIS DOCUMENT 1S FOR
PLANNING AND INFORMATION PURPOSES ONLY AND IS CONCEPTUAL. THIS IS SOLELY THE PHOTOGRAPHER'S
INTERPRETATION OF THE PROPOSED DEVELOPMENT.
Existing
. i 1 i L
APPROX. DEC 111015
•PHOTO Community/
LOCATION Developrnent
*. APPROX.
PROPOSED
ANTENNA
LOCATIONS
I-r L_ 1 : i l L i I�
CENTERLINE
T la 13
obile e�
SOUTH CENTER PLACE
Looking Southwest
(N) T-MOBILE PANEL ANTENNAS, TYP OF
(1) PER SECTOR, TOTAL OF (3),
MOUNTED ON (E) WALL PIPE MOUNTS
NOT VISIBLE FROM THIS LOCATION
-SEE NOTES
•
Proposed tJ5»tZ7 ?
4
NOTES:
1. PM/GC TO VERIFY PAINTING REQUIREMENTS WITH JURISDICTION PRIOR TO ORDERING SUPPORT STRUCTURES,
ATTACHMENTS, ANTENNAS, AND OTHER APPURTENANCES.
2. VISUAL IMPACTS WILL BE AFFECTED BY LOCATION AND VISIBILITY OF OBSERVER. THIS DOCUMENT IS FOR
PLANNING AND INFORMATION PURPOSES ONLY AND IS CONCEPTUAL. THIS IS SOLELY THE PHOTOGRAPHER'S
INTERPRETATION OF THE PROPOSED DEVELOPMENT.
Tr
UQ
SOUTH CENTER PLACE
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
SITE ID: SE04000B
CONSTRUCTION DRAWINGS
PROJECT SUMMARY
THIS PROJECT INCLUDES THE FOLLOWING SCOPE OF WORK
PROPOSED MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY.
MODIFICATIONS TO ROOFTOP EQUIPMENT INCLUDE"':
" REMOVAL OF (2) EXISTING PANEL ANTENNAS (TMBXX-6516-R2M, GAMMA SECTOR ONLY)
" ADDITION OF (1) NEW PANEL ANTENNAS (DBXNH-6565E-A2M, GAMMA SECTOR ONLY)
• ADDITION OF (2) NEW PANEL ANTENNAS (HBXX-3319DS-A2M, GAMMA SECTOR ONLY)
• ADDITION OF (1) FRIG AND (1) FXFC (GAMMA SECTOR ONLY)
• ADDITION OF (6) DIPLEXERS (ECC1920-VPUB, GAMMA SECTOR ONLY)
• ADDITION OF (2) FSMF, (2) FBBC, & (1) ESMB IN (E) CABINET
ALL OTHER EXISTING EQUIPMENT TO REMAIN, SEE FJNAL EQUIPMENT EIVENTORY
TABLE ON A4.0 FOR COMPLETE SPECIFICATIONS.
PROJECT VICINITY & AERIAL MAPS
SITE INFORMATION
SITE NAME:
SITE ID:
SITE ADDRESS:
LATITUDE:
LONGITUDE:
SOURCE:
PARCEL NUMBER:
ZONING CLASSIFICATION:
JURISDICTION:
TOP OF (E) PENTHOUSE:
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
SOUTHCENTER PLACE
SE04000B
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
47°27'19.0" N (47.455278)
122°15'42.0" W (122.261667)
1A
2623049021
TUC
CITY OF TUKWILA
73.0' AGL
U
I I-B
DRIVING DIRECTIONS
FROM T-MOBILE BOTHELL OFFICE
1. TAKE RAMP LEFT FOR 1-405 SOUTH TOWARD RENTON (24.2 MI)
2. TAKE RAMP RIGHT FOR 1-5 NORTH TOWARD SOUTHCENTER BLVD &
MALL (0.3 MI)
3. TURN RIGHT ONTO SOUTHCENTER BLVD (0.3 MI)
4. TURN RIGHT ONTO 61ST AVE S (0.1 MI)
5. TURN RIGHT ONTO SOUTHCENTER PKWY (0.6 MI)
6. ARRIVE AT 16400 SOUTHCENTER PKWY, TUKWILA, WA 98188
ESTIMATED DISTANCE:
ESTIMATED TIME:
26.0 MILES
30 MINUTES
6.05°
GOVERNING CODES
IBC-2012, INTERNATIONAL BUILDING CODE W/ LOCAL
AMENDMENTS
NEC-2008, NATIONAL ELECTRICAL CODE
A.D.A. COMPLIANCE
INSTALLATION IS UNMANNED AND NOT FOR HUMAN
HABITATION. HANDICAP ACCESS IS NOT REQUIRED
PER A.DA.
PROJECT CONTACTS DRAWING INDEX
APPLICANT
T-MOBILE
19807 NORTH CREEK PKWY N
BOTHELL, WA 98011
PROPERTY OWNER
LEGACY PARTNERS COMMERCIAL
4000 E THIRD AVE, SUITE 600
FOSTER CITY, CA 94404
PROJECT CONSULTANT
CENTERLINE SOLUTIONS
8218 154TH AVE NE
REDMOND, WA 98052
RICK STOCKMANN
PH: 425.890.1437
SITE ACQUISITION CONSULTANT
CENTERLINE SOLUTIONS
8218 154TH AVE NE
REDMOND, WA 98052
RICK STOCKMANN
PH: 425.890.1437
ZONING & PERMITTING CONSULTANT
CENTERLINE SOLUTIONS
8218 154TH AVE NE
REDMOND, WA 98052
RICK STOCKMANN
PH: 425.890.1437
CONSTRUCTION MANAGER
CENTERLINE SOLUTIONS
8218 154TH AVE NE
REDMOND, WA 98052
RICK YOUNG
PH: 425.954.8613
RF ENGINEER
T-MOBILE
19807 NORTH CREEK PKWY N
BOTHELL, WA 98011
GLENN DIME
STRUCTURAL ENGINEER
VECTOR STRUCTURAL ENGINEERS
9138 S STATE STREET, SUITE 101
SANDY, UT 84070
ROGER T. ALWORTH, S.E.
PH: 801.990.1775
RECEIVED
DEC 112015
Community
Development
SHEET
T1.0
GN1.0
A1.0
A1.1
A2.0
A3.0
A4.0
A5.0
A6.0
RF1.0
DESCRIPTION
TITLE SHEET
GENERAL NOTES
OVERALL SITE PLAN
ENLARGED ROOF PLAN
ENLARGED EQUIPMENT PLAN
ELEVATIONS
ANTENNA DETAILS & PLANS
ANTENNA & EQUIPMENT DETAILS
CONSTRUCTION DETAILS
RF DETAILS
Know what's below.
CaII before you dig.
THE INFORMATION CONTAINED IN THIS SET
OF DOCUMENTS IS PROPRIETARY BY
NATURE. ANY USE OR DISCLOSURE OTHER
THAN THAT WHICH RELATES TO T-MOBILE
SERVICES IS STRICTLY PROHIBITED.
SIGN OFF OF FINAL CONSTRUCTION DRAWINGS
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH
REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
CONSULTANT
SIGNATURE
DATE
SITE ACQUISITION
PERMITTING CONSULTANT
RF ENGINEER:
CONST. MNGR.
OPS MNGR.
PROJECT MNGR.
REGULATORY REV.
DEV. MNGR.
T. It
obi1e-
,i( CENTERLINE
WLdeaAMraAs
v
• Il • I Il ■ • R •
af+
z4�
iU d
11/12/15 EXP. 1/27/16
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
1
11-11-15
MS/MS
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400
SOUTHCENTER PARKWAY
TUKWILA, WA 98188
SHEET TIRE
TITLE
SHEET
SHEET NO.
T1.0
4/5---vosasT
GENERAL NOTES
1. THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY.
2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE FINAL
INSTALLATION. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND
LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE
FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS AND CONFIRMING THAT THE
WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY
DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER.
4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK.
5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE
LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.
6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH
APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND
COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC
AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS
SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY
SPECIFICATIONS AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE
REGULATIONS.
7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION. THE
CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK
UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT MANAGER AND
WITH LANDLORD'S AUTHORIZED REPRESENTATIVE.
8. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 5
FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION.
9. THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE, AND KEEP SAME ON SITE
WHENEVER ANY PERSONNEL ARE ON SITE.
10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED
TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF
THE WORK.
11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS,
PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY DAMAGE
THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT MANAGER AND/OR
LANDLORD.
12. ON A DAILY BASIS: KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS,
RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES
IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE.
13. CONTRACTOR TO PROVIDE COMPLETE SET OF AS -BUILT DRAWINGS WITHIN 10 WORKING DAYS OF
PROJECT COMPLETION.
14 WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR
OTHER SIMILAR WORK.
15. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
16 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER
SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL
EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK.
17. ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR REPAIRED TO
MATCH EXISTING.
18. ALL ELEMENTS OF EXISITNG STRUCTURE TO REMAIN INDISTURBED, UNO. EXISTING STRUCTURE IS
ASSUMED TO BE IN GOOD CONDITION, FREE OF DAMAGE OR DETEREORATION. CONTRACTOR TO VERIFY
ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY THIS MODIFICATION AND NOTIFY FOR IF ANY
DAMAGE, DETEREORATION, OR DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THOSE
DEPICTED ON THESE CONSTRUCTION DRAWINGS ARE FOUND.
SPECIAL INSPECTION
1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL
INSPECTOR.
2. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER, ARCHITECT,
STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED.
3. ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. SPECIAL
INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS.
4. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL USED
IF THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED
DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND
FURNISHES EVIDENCE OF COMPLIANCE.
5. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT CERTIFYING THAT ALL WORK REQUIRING
SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE IN
CONFORMANCE WITH THE APPROVED PERMIT PLANS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS.
STRUCTURAL NOTES
GENERAL STRUCTURAL NOTES:
1. WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS
FOR OTHER SIMILAR WORK.
2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES.
3. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS
SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES,
DUCTS, ETC., UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR
INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC.
4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB
SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND,
INDEMNIFY AND HOLD T-MOBILE AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL
LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF T-MOBILE OR THE
ARCHITECT/ENGINEER.
5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO
NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES
NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND PEDESTRIANS DURING
CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING
FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY
COMPLETED WQRK, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL
NOT INCLUDE INSPECTION OF SUCH ITEMS.
6. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF. LOAD
SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE
SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH.
8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES
WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR
SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION
OF THIS WORK.
9. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS.
10. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS.
11. ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E., DRYWALL, PLYWOOD, CEILING PANELS,
ETC.) SHALL BE REPLACED TO MATCH EXISTING.
THE FOLLOWING REQUIREMENTS SHALL BE MET FOR SPECIAL INSPECTION:
A. THE SPECIAL INSPECTOR SHALL BE UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL
ENGINEER.
B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE ARCHITECT/ENGINEER,
AND OTHER DESIGNATED PERSONS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER
DESIGN AUTHORITY AND THE BUILDING OFFICIAL.
C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS
SUPERVISOR STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN
CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS OF THE CODE.
D. COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS.
STANDARD STRUCTURAL STEEL NOTES:
1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM
A123-A123M-02 UNLESS NOTED OTHERWISE.
2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, GRADE A OR A501.
3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC
AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER
TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION", 14TH EDITION.
4. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV. ASTM A307 BOLTS (5/8" DIA. UNO) AND
SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL INCLUDE HEAVY -HEX NUTS AND
STANDARD CUT WASHERS. @@��qq IImo�TSfi..
5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AI�[iSLIVYIR'' DIA
GALVANIZED ASTM A307 BOLTS U.N.O. dd LanISM.
6. ALL STRUCTURAL PIPE ASTM A53, TYPE E OR S, GRADE B.
DEC 112015
SPECIAL INSPECTION:
1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN ►pIUEPI�I$I itOtCIAL
INSPECTOR PER CODE FOR THE FOLLOWING ITEMS: 1 eVe Opfleflt
A. CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS: INSPECT
HOLE SIZE, DEPTH, CLEANLINESS, AND INSTALLATION PER ICC REPORT.
B. PERIODIC FOR HIGH STRENGTH BOLT INSTALLATIONS (A325).
DRAWING ABBREVIATIONS
AFF
ABOVE FINISH FLOOR
LF
LINEAR FEET
AGL
ABOVE GRADE LEVEL
MAX
MAXIMUM
AWG
AMERICAN WIRE GAUGE
MECH
MECHANICAL
AC
AIR CONDITIONING
MFR
MANUFACTURER
ADJ
ADJUSTABLE
MGR
MANAGER
APPROX
APPROXIMATELY
MIN
MINIMUM
AZ
AZIMUTH
MISC
MISCELLANEOUS
BLDG
BUILDING
MTL
METAL
CM
CONSTRUCTION MANAGER
MTZL
METALIZE(D)
CAB
CABINET
MW
MICROWAVE
CL
CENTERLINE
NEC
NATIONAL ELECTRICAL CODE
CLG
CEILING
NIC
NOT IN CONTRACT
CLR
CLEAR
NTS
NOT TO SCALE
CO
COPPER
N/A
NOT APPLICABLE
CONC
CONCRETE
OC
ON CENTER
COND
CONDUIT
OD
OUTSIDE DIAMETER
CONST
CONSTRUCTION
OP
OVERHEAD POWER
CONT
CONTINUOUS
OT
OVERHEAD FIBER
CPM
CASCADIA PM
OPP
OPPOSITE
D/C
DRAFTER/CHECKER
PL
PROPERTY LINE
DEMO
DEMOLISH
PLYWD
PLYWOOD
DIA
DIAMETER
PM
PROJECT MANAGER
DIM
DIMENSION
PROJ
PROJECT
DN
DOWN
PROP
PROPERTY
DTL
DETAIL
PT
PRESSURE TREATED
DWG
DRAWING
RO
ROUGH OPENING
EA
EACH
ROW
RIGHT OF WAY
ELECT
ELECTRICAL
RRU
REMOTE RADIO UNIT
ELEV
ELEVATION
REQ
REQUIRED
EQ
EQUAL
SBTC
SOLID BARE TINNED COPPER
EQUIP
EQUIPMENT
SF
SQUARE FEET
EXT
EXTERIOR
SHT
SHEET
FIN
FINISH
SPEC
SPECIFICATION
FLR
FLOOR
SO
SQUARE
FT
FOOT, FEET
SS
STAINLESS STEEL
GA
GAUGE
STL
STEEL
GALV
GALVANIZED
STRUCT
STRUCTURE, STRUCTURAL
GC
GENERAL CONTRACTOR
TOC
TOP OF CONCRETE
GWB
GYPSUM WALL BOARD
TOM
TOP OF MASONRY
GR
GRADE
THRU
THROUGH
GRND
GROUND
TNND
TINNED
HVAC
HEATING, VENTING 8 AIR CONDITIONING
UBC
UNIFORM BUILDING CODE
HORIZ
'HORIZONTAL
UG
UNDERGROUND
HT
HEIGHT
UNO
UNLESS NOTED OTHERWISE
IBC
INTERNATIONAL BUILDING CODE
UP
UNDERGROUND POWER
ID
INSIDE DIAMETER
OF
UNDERGROUND FIBER
IN
INCH
VIF
VERIFY IN FIELD
INSUL
INSULATION
VERT
VERTICAL
INT
INTERIOR
WP
WATERPROOF
JBOX
JUNCTION BOX
W/
WITH
LB(S)
POUND(S)
W/O
WITHOUT
m •Mobile -
4 CENTERLINE
AdhdigWLdatNew rb
/ ■ 11 • 1 rl ■ ■ R •
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
BUBMTTAL
NO.
DATE
D/C
DESCRIPTION
1
11-11-15
MS/MS
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
S E04000 B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
SHEET TITLE
GENERAL
NOTES
SHEET NO.
GN1.0
,g.c10s9
1
J
T-MOBILE PROJECT AREA
BUILDING (TYP)
SEE SHEET A4.0
STRANDER BLVD
I
PARCEL #: 2623049021
r
T-MOBILE PROJECT AREA
SEE SHEET A2.0
INGRESS/EGRESS
FROM STRANDER BLVD
(E) ADJACENT
PROPERTY LINE (TYP)
(E) SUBJECT
PROPERTY LINE (TYP)
DRAWING LEGEND
- - - SUBJECT PROPERTY LINE
- - ADJACENT PROPERTY LINE
COAX COAX ROUTE
HYBRID HYBRID CABLE ROUTE
EXISTING FENCE
® ELEVATION MARKER
ArkDETAIL REFERENCE
® SECTION MARKER
COMMON ABBREVIATIONS
(E) EXISTING
(N) NEW ABBREVIATIONS CONTINUED
(TYP) TYPICAL ONSHEETGN1.0
NOTE:
SITE PLAN DERIVED FROM; EXISTING DRAWINGS, GIS, AERIAL
IMAGES AND SITE PHOTOS.
/56--e05.9
RECEVE
DEC 112015
Community
Development
S
1
OVERALL SITE PLAN
SCALE: 1" = 40'-0" (11 X17)
SCALE: 1" = 20'-0" (22X34)
0' 20'
40'
80'
T • -Mobile
>CENTERLINE
Aahhdig NLelars'Woods
e/\
/ ■ A • 1 A ■ ■ R •
CPM PROJECT NO.: 8856
PRELJMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION _
1
11-11-15
MS/MS
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TU KW ILA, WA 98188
SHEET TITLE
ENLARGED
ROOF PLAN
SHEET NO.
A1.1
(E) T-MOBILE ANTENNAS, TYP
OF (2) IN GAMMA SECTOR
ONLY, TO BE REMOVED
(E) T-MOBILE DIPLEXER (TYP
OF 2 PER SECTOR, 6 TOTAL)
TO REMAIN
(E) PENTHOUSE
BETA SECTOR
GAMMA SECTOR
r
•
(E) T-MOBILE FXFB (RRU) (TYP OF 1
PER SECTOR, 3 TOTAL) TO REMAIN
(E) T-MOBILE TMA (TYP OF 2 PER
SECTOR, 6 TOTAL) TO REMAIN
(E) ROOFTOP VENT, TYP.
(E) T-MOBILE FRLB MOUNTED BEHIND
ANTENNA ON (E) PIPE MOUNT (TYP
OF 1 PER SECTOR, 3 TOTAL)
ALPHA SECTOR
DEC 112015
Community
Development
(E) T-MOBILE ROOFTOP
MOUNTED EQUIPMENT
BELOW
(E) T-MOBILE FRIG (RRU)
(TYP OF 1 PER SECTOR, 3
TOTAL) TO BE RELOCATED
(E) PENTHOUSE VENT,
TYP.
(E) T-MOBILE COVP (TYP
OF 1 PER SECTOR, 3
TOTAL) TO REMAIN
(E) T-MOBILE PANEL
ANTENNAS, TYP OF (4) TO
REMAIN
w
16.05°
S
DRAWING LEGEND
- - - - - SUBJECT PROPERTY LINE
- - ADJACENT PROPERTY LINE
COAX COAX ROUTE
HYBRID HYBRID CABLE ROUTE
- EXISTING FENCE
ArkELEVATION MARKER
ink
DETAIL REFERENCE
® SECTION MARKER
COMMON ABBREVIATIONS
(E) EXISTING
(N) NEW ABBREVIATIONS CONTINUED
(TYP) TYPICAL ON SHEET GN1.0
(N) T-MOBILE PANEL ANTENNAS (TYP OF 2)
MOUNTED ON (E) WALL PIPE MOUNTS;
SUITABILITY OF MOUNT FOR FINAL LOADING
CONFIGURATION TO BE VERIFIED BY
OTHERS PRIOR TO INSTALLATION
(N) T-MOBILE DIPLEXERS, TYP OF (3), (6
TOTAL), TO BE MOUNTED BEHIND (N) HBXX
MODEL ANTENNAS
(N) T-MOBILE FXFC, MOUNTED ON (E)
PLATFORM W/ (E) FXFB UNIT
BETA SECTOR
50 etc?
4, .'‘P
44•&,.
GAMMA SECTOR
i
(N) T-MOBILE PANEL ANTENNAS (TYP
OF 1) MOUNTED ON (N) WALL PIPE
MOUNT, SEE 1/A6.0
(N) T-MOBILE FRIG (RRU) MOUNTED
BEHIND (N) ANTENNA ON (N) PIPE
MOUNT BELOW (E) FRIG
4.
(E) T-MOBILE FXFB (RRU) (TYP OF 1
PER SECTOR, 3 TOTAL) TO REMAIN
•
(E) T-MOBILE TMA (TYP OF 2 PER
SECTOR, 6 TOTAL) TO REMAIN
•
♦
L
(N) T-MOBILE DIPLEXERS, TYP
OF (3), (6 TOTAL), TO BE
MOUNTED BEHIND (N) HBXX
MODEL ANTENNAS
(E) T-MOBILE COVP
(TYP OF 1 PER
SECTOR, 3 TOTAL)
TO REMAIN
(E) T-MOBILE PANEL
ANTENNAS, TYP OF (4) TO
REMAIN
ALPHA SECTOR
(E) PENTHOUSE; CAPACITY
TO SUPPORT THE
PROPOSED LOADING
CONFIGURATION TO BE
ANALYZED BY OTHERS
LfS OO59
(E) T-MOBILE FRLB MOUNTED BEHIND
ANTENNA ON (E) PIPE MOUNT (TYP
OF 1 PER SECTOR, 3 TOTAL)
w
6.05°
S
1
ENLARGED ROOF PLAN - EXISTING
SCALE: 1/8" = 1'-0" (11X17)
SCALE: 1/4" = 1'-0" (22X34)
0'
4'
8'
16'
111
1
ENLARGED ROOF PLAN - FINAL
SCALE: 1/8" = 1'-0" (11X17)
SCALE: 1/4" = 1-0" (22X34)
0' 4' 8'
16'
i i
T • •Mobile-
0'CENTERL1NE
Mincing WLdnsNaleals
■ A • I A ■ ■ R •
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
0
10-22-15
MS/MS
DESCRIPTION
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
NO.
1
DATE
11-11-15
D/C
MS/MS
DESCRIPTION
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TUKWILA, WA98188
SHEET TITLE
OVERALL
SITE PLAN
SHEET NO.
Al .0
ROUTE OF (12)
(E) T-MOBILE (7/8") COAX
(E) T-MOBILE ANTENNAS &
ANCILLARY EQUIPMENT;
SEE SHEET A4.0
HYBRID
(E) T-MOBILE HI -CAP HYBRID
FIBER ROUTED W/ (E) COAX
(50 LF, 50 LF & 75 LF)
HYBRID HYBRID '
HYBF ID
COAX
HYBRID -
COAX
E) T-MOBILE PURCELL
CABINET TO REMAIN
(1) (E) RECTIFIER IN (E) PDU
1
(E) T-MOBILE COVP AT EQUIP.
(TYP. OF 3) TO REMAIN
W
S
1
(E) ENLARGED EQUIPMENT PLAN
SCALE: 1 /2"= 1'-0" (11X17)
SCALE: 1" = 1'-0" (22X34)
0' 1'
2'
4'
IM i
ROUTE OF (12)
(E) T-MOBILE (7/8") COAX
(N) T-MOBILE ANTENNAS &
ANCILLARY EQUIPMENT;
SEE SHEET A4.0
HYBR
COAX
HYBRID
HYBRID
FIECEVED
DEC 112015
Community
Development
(E) T-MOBILE HI -CAP HYBRID FIBER ROUTED
W/ (E) COAX (50 LF, 50 LF & 75 LF)
HYBRID
(E) T-MOBILE PURCELL
CABINET TO REMAIN
(1) (E) RECTIFIER IN (E) PDU
(E) T-MOBILE COVP AT EQUIP.
(TYP. OF 3) TO REMAIN
WITHIN (E) T-MOBILE CABINET,
7 INSTALL THE FOLLOWING EQUIPMENT:
" (2) FSMF
• (2) FBBC
• (1) ESMB
REPLACE U1900 SYSTEM MODULE W/:
"(1) FSMF
" (1) FBBC
16.05°
2
(N) ENLARGED EQUIPMENT PLAN
SCALE: 1/2"=1'-0" (11X17)
SCALE: 1" =1'-0" (22X34)
0' 1'
2'
4'
■ i�
--Mobile-
4)CENTERLINE
Aden ig Maker N m*
\ V
/ ■ n • I Il R e ae
11/12/15 EXP. 1/27/16
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
1
11-11-15
MS/MS
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TUKWILA, WA98188
SHEET TITLE
ENLARGED
EQUIPMENT PLAN
SHEET NO.
A2.0
(E) T-MOBILE PANEL ANTENNAS IN GAMMA
SECTOR, TOTAL OF (2), TO BE REMOVED
(E) T-MOBILE ANTENNA TIP HEIGHT
®
® ®
iYYY
1�
10�
i �y
T��JJJ 111e�
81.3' \ (E) T-MOBILE PANEL ANTENNAS IN ALPHA AND
(E) T-MOBILE ANTENNA RAD CNTR. BETA SECTOR, TOTAL OF (4), TO REMAIN
I�
C E N T E R L I N E
*Mindy t44d‘sANt•cnb
78.3' 8 78.8' \
At (E) TOP OF PENTHOUSE
C
li
�t1
T-MOBILE FRLB MOUNTED BEHIND
73.0' —_,_— r (E)
ANTENNA ON (E) PIPE MOUNT (TYP
:) OF 1 PER SECTOR, 3 TOTAL)
"�
/t (E) TOP OF ROOF
)11 n Pn •IIIRS
'4'62.8' -- ---
T-MOBILE BTS EQUIPMENT TO REMAIN
�
I
i
(E)
_ _
(E) T-MOBILE FRIG (RRU) (TYP OF 1 �"
PER SECTOR, 3 TOTAL) TO REMAIN
1
j
I I
1
j
(E) T-MOBILE COVP (TYP OF 1 PER
SECTOR, 3 TOTAL) TO REMAIN
•
L
rt _
\ BUILDING
(E) T-MOBILE DIPLEXER (TYP OF 2 PER
SECTOR, 6 TOTAL) TO REMAIN
I I
I I I
, I
r
i
(E)
1.
''�r°
1
(E) T-MOBILE TMA (TYP OF 2 PER
L
_
SECTOR, 6 TOTAL) TO REMAIN
a-
!
✓
" d
r y�
� 'i
(E) T-MOBILE FXFB (RRU) (TYP OF 1
PER SECTOR, 3 TOTAL) TO REMAIN
(E) GRADE 0.0' AGL
i
I
SCALE: 1"=2o'-0"(„X,7)
o' ,o' 20' 40'�
1
EXISTING NE ELEVATION
SCALE: 1" = 10'-0" (22X34)
III III
11/12/15
EXP. 1/27/16
T-MOBILE PANEL ANTENNAS IN GAMMA
(NOTES:
(N) T-MOBILE ANTENNA TIP HEIGHT
(N)
SECTOR ONLY (TYP OF 3) MOUNTED ON (E)
(E) T-MOBILE
ANTENNA
TIP HEIGHT ,�
CPM
PROJECT NO.: 8856
81.3'
Ain (N) T-MOBILE ANTENNA RAD CNTR. \
& (N) WALL PIPE MOUNTS
(E) T-MOBILE
/
ANTENNA
81.3' 1
RAD CNTR. di
• IF REQUIRED, PAINT TO MATCH ANTENNAS AND ANCILLARY EQUIPMENT TO MATCH
- THE EXISTING STRUCTURE WITH NON -REFLECTIVE PAINT AS REQ'D. CONTRACTOR
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
78,3 & 78.8
TO VERIFY COLOR AND FINISH WITH LANDLORD AND/OR JURISDICTION.
78.3' & 78.5'
\
i
/
• PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY
0
10-22-15
MS/MS
90% CD REVIEW
E TOP OF PENTHOUSE
/I. { )
"-
CONDITION OF STRUCTURE AT PROPOSED MOUNTING LOCATION TO ENSURE
EXISTING CONDITIONS ARE SUITABLE AT SPECIFIED ELEVATION.
1
11-11-15
MS/MS
CLIENT COMMENT
`r 73.0'
I �
r
(E) T-MOBILE PANEL
BETA SECTOR,
ANTENNAS IN ALPHA
TOTAL OF (4), TO REMAIN
AND
•NEW ANTENNAS SHALL NOT EXCEED EXISTING TIP HEIGHT U.N.O.
• RETURN ALL USED EQUIPMENT AND HARDWARE TO T-MOBILE WAREHOUSE.
SUBMITTAL
•
�:= � s•
• ALL CLIMBING PATHS ON TOWER/MONOPOLE TO REMAIN FREE & CLEAR OF
NO.
DATE
D/C
DESCRIPTION
(
MOUNTS, EQUIPMENT, ETC.
(E) TOP OF ROOF
.11A
(E) T-MOBILE FRLB
MOUNTED BEHIND
1
11-11-15
MS/MS
BP SUBMITTAL
62.8'
ANTENNA ON (E)
PIPE MOUNT (TYP
(N) T-MOBILE FRIG (RRU) MOUNTED BEHIND
(N) ANTENNA ON (N) PIPE MOUNT
1
OF 1 PER SECTOR,
'
i (E) T-MOBILE FXFB
3 TOTAL)
I ' 1
(RRU) (TYP OF 1
i
( j
SITE NAME;
PER SECTOR, 3
TOTAL) TO REMAIN
SOUTHCENTER
PLACE
SITE ID:
(E) T-MOBILE BTS EQUIPMENT TO REMAIN
(N) T-MOBILE FXFC, MOUNTED ON (E)
11
T-
-
PLATFORM W/ (E) FXFB UNIT
...
- - _
S E04000 B
SITE
(N) T-MOBILE DIPLEXERS, TYP OF (6), (8
I
TOTAL), TO BE MOUNTED BEHIND (N)
HBXX MODE (STING ANTENNAS (3 NEW 8 1
EXISTING PER ANTENNA)
; � I
1 I
L ;_ 1 �
- _T__
I �� V
�J 5q
SOUTHCADDFtEENTER
16400 SOUTHCENTER PARKWAY
TUKWI A 98188
4/
(E) T-MOBILE FRIG (RRU) (TYP OF 1
PER SECTOR, 3 TOTAL) TO REMAIN
T-MOBILE T PER
i
I r
I
�'��.� V �f �
SHEET THEE
ELEVATIONS
(E) OR, ,
3TOTAL) VP
SECTOR, 3 TTO REMAIN
L)
(E) T-MOBILE DIPLEXER (TYP OF 2 PER
SECTOR, 6 TOTAL) TO REMAIN
(E) T-MOBILE TMA (TYP OF 2 PER
SECTOR, 6 TOTAL) TO REMAIN
DEC 112015
Develoo UnComey
pment
SHEET NO.
A3 .
0
SCALE: 1" = 20'-0" (11X17)
0' 10' 20' 40'
2
FINAL NE ELEVATION
SCALE: 1"=10'-0"(22X34)
al E
GAMMA SECTOR
sM01
ANTENNA SCHEDULE - FINAL CONFIGURATION
y '; a
S
7 ,c
Cy m �x
5��2 q
o1 (E) T-MOBILE FRIG (RRU) (TYP OF 1
T,? PER RELOCATED R, 3 TOTAL) TO BE
o O
w °',
S./3
(E) T-MOBILE COVP (TYP
OF 1 PER SECTOR, 3
T-MOBILE ANTENNAS, TYP OF (2) IN / '•. ;-' TOTAL) TO REMAIN
GAMMA SECTOR ONLY, TO BE REMOVED
(E).��
(E) T-MOBILE DIPLEXER (TYP OF 2 PER (E) T-MOBILE FXFB (RRU) (TYP OF 1
SECTOR, 6 TOTAL) TO REMAIN PER SECTOR, 3 TOTAL) TO REMAIN ' ,�:
(E) T-MOBILE TMA (TYP OF 2 PER 6'
SECTOR, 6 TOTAL) TO REMAIN 9‘ay )y
706,
70 Se
(E) PENTHOUSE; CAPACITY O°
TO SUPPORT THE
6�®.• PROPOSED LOADING
�p�'ry� ' "' CONFIGURATION TO BE
}' ,`ti ANALYZED BY OTHERS (E) T-MOBILE PANEL
�� Q'S` ANTENNAS, TYP OF (4) TO
Q 16.05°
�0� 0 ✓� REMAIN
d`o . N
Ztr i)- y�6' TN MN
0� (E) T-MOBILE FRLB MOUNTED BEHIND ti B}' ALPHA SECTOR
SECTOR
POS.
EXIST. / NEW
MNFR.
ANTENNA MODEL
PORT
DIMENSIONS
(L x W x D)
WEIGHT
(LBS)
CENTERLINE
Adwxig W5•f•ttAM•ab
Al
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
ALPHA
A2
EXISTING
COMMSCOPE
SBNHH-1D656
HEX
72.6" x 11.9" x 7.1"
40.6
B1
EXISTING
ANDREW
TMBXX-6516-R2M
QUAD
59.0" x 11.9" x 6.3"
34.6
BETA
B2
EXISTING
COMMSCOPE
SBNHH-1D65B
HEX
72.6" x 11.9" x 7.1"
40.6
Cl
NEW
COMMSCOPE
HBXX-3319DS-A2M
QUAD
57.0" x 22.2" x 4.9"
38.1
n CTOR
■ • i n ■ ■ R •
GAMMA
C2
NEW
COMMSCOPE
DBXNH-6565E-A2M
QUAD
72.7" x 11.9" x 7.1"
46.3
DELTA
D3
NEW
COMMSCOPE
HBXX-3319DS-A2M
QUAD
57.0" x 22.2" x 4.9"
38.1
*TOWER - FINAL EQUIPMENT INVENTORY
SCOPE
QTY.
TECHNOLOGY
MNFR.
MODEL
DIMENSIONS
(L X W X D)
WEIGHT
(LBS)
(E) TO REMAIN
(2)
ANTENNA
ANDREW
TMBXX-6516-R2M
59.0" x 11.9" x 6.3"
34.6
REMOVE (E)
(1)
ANTENNA
ANDREW
TMBXX-6516-R2M
59.0" x 11.9" x 6.3"
(34.6)
(E) TO REMAIN
(2)
ANTENNA
COMMSCOPE
SBNHH-1 D656
72.6" x 11.9" x 7.1"
40.6
/ "
11/12/15
I. ,«
i -
j� .� _� °
i
( a
�p
T !k'.Y$S y
A
'
EXP. 1/27/16
REMOVE (E)
(1)
ANTENNA
COMMSCOPE
SBNHH-1 D65B
72.6" x 11.9" x 7.1"
(40.6)
ADD (N)
(1)
ANTENNA
COMMSCOPE
DBXNH-6565B-A2M
72.7" x 11.9" x 7.1"
46.3
ADD (N)
(2)
ANTENNA
COMMSCOPE
HBXX-3319DS-A2M
57.0" x 22.2" x 4.9"
38.1
(E) TO REMAIN
(3)
RRU
NOKIA
FXFB
19.3" x 22.0" x 5.2"
55.0
ANTENNA ON (E) PIPE MOUNT (TYP '60 W E
(E) TO REMAIN
(3)
RRU
NOKIA
FRIG
23.8" x 17.2" x 7.5"
59.9
4-
BETA SECTOR ��' OF 1 PER SECTOR, 3 TOTAL) ./,x
d0°QA,
ADD (N)
(1)
RRU
NOKIA
FRIG
23.8" x 17.2" x 7.5"
59.9
SA
ADD (N)
(1)
RRU
NOKIA
FXFC
19.3" x 22.0" x 5.2"
55.0
SCALE: NTS (11X17)
(E) TO REMAIN
(3)
COVP
RAYCAP
CR100-1076R06
20.2" x 19.0" x 7.0"
15.0
2
EXISTING ANTENNA PLAN
SCALE: NTS (22X34)
(E) TO REMAIN
(6)
TMA
ANDREW
DU
(DUAALL AWSWS/PCSCS)
9.4" x 7.3" x 3.5"
13.9
(N) T-MOBILE PANEL ANTENNAS (TYP OF 1)
OAMMA SECTOR 0 2 MOUNTED ON (N) WALL PIPE MOUNT,' SEE 1/A6.0
7�
CPM
PROJECT NO.: 8856
PRELIMINARY
(E) TO REMAIN
(6)
DIPLEXER
COMMSCOPE
ECC1920-VPUB
7.6" x 7.3" x 2.6"
7.9
�� (N) T-MOBILE FRIG (RRU) MOUNTED BEHIND (N) ANTENNA
y><y ON (N) PIPE MOUNT BELOW (E) RELOCATED FRIG
�y
"
c�-4,-+
�905,ft
/5- ` x) �I
v(L
(N) T-MOBILE PANEL ANTENNAS (TYP OF 2) ?QMOUNTED ON (E) WALL PIPE MOUNTS;(E)
SUITABILITYOF MOUNT FOR FINAL LOADING CONFIGURATION TO BE VERIFIED BY •
OTHERS PRIOR TO INSTALLATION
(E) T-MOBILE COVP (TYP
NO.
DATE
D/C
DESCRIPTION
ADD (N)
(6)
DIPLEXER
COMMSCOPE
ECC1920-VPUB
7.6" x 7.3" x 2.6"
7.9
0
10-22-15
MS/MS
90%CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
*GROUND - FINAL EQUIPMENT INVENTORY
NO.
DATE
D/C
DESCRIPTION
QTY.
TECHNOLOGY
MNFR.
MODEL
DIMENSIONS
X W X D)
WEIGHT,
(LBS)
1
11-11-15
MS/MS
BPSCOPE
TO REMAIN
(3)
COVP
RAYCAP
RNSNDC-7771-PF-48
18.85" x 16.08" x 5.83"
19.0
SITE NAME:
Fi Ea. C F !7 �.. 1
.•.. O
DEC 112015
SOUTHCENTER
PLACE
SITE ID:
�--
(N) T-MOBILE DIPLEXERS, TYP OF (3), (6 OF 1 PER SECTOR, 3
K.
TOTAL), TO BE MOUNTED BEHIND (N) �'\ TOTAL) TO REMAIN
(E) T-MOBILE FXFB (RRU) (TYP OF 1
HBXX MODEL ANTENNAS PER SECTOR, 3 TOTAL) TO REMAIN
(N) T-MOBILE
M W/ (E) FXDFB UNIT
(E) T-MOBILE TMA (TYP OF 2 PER F
SECTOR, 6 TOTAL) TO REMAIN glo`s6,I
y�-��'/
, �sSB
/, "'O°
(E) PENTHOUSE; CAPACITY
�L� TO SUPPORT THE
^ti° PROPOSED LOADING
.i_54.0 CONFIGURATION TO BE
fit' orl' ANALYZED BY OTHERS (E) T-MOBILE PANEL
ANTENNAS, TYP OF (4) TO
tr, 4' REMAIN
�� co°
���ry0 FT TN
(E) T-MOBILE FRLB MOUNTED BEHIND Ay�eG ALPHA SECTOR
8.05°
N
MN
SE04000B
$ ADDRESS:ITE
• THE "TOWER" AND "GROUND" REFERENCES REFER TO NOMENCLATURE REFLECTED IN THE PLUMBINy V�� RAM
AND DO NOT NECESSARILY REFER TO ACTUAL LOCATION OF EQUIPMENT. L `�-,e
GROUND EQUIPMENT NOTE
�7 'J�1'h,
ON TbT RF1.0 SHEET
oilmen
16400 SOUTHCENTER PARKWAY
TUKWILA, WA98188
• NEW FBBC TO BE INSTALLED IN EXISTING FCOA CABINET (QUANTITIES MAY VARY). ALL OTHER BASEBAND MODULES ARE ASSUMED TO
BE EXISTING.
ANTENNA NOTES:
SHEET TITLE
ANTENNA
DETAILS & PLANS
• REFERENCE OWNERS MANUAL FOR CONNECTION AND MOUNTING INFORMATION FOR AMPLIFIER IF REQUIRED.
• CONTRACTOR SHALL VERIFY FINAL ANTENNA AZIMUTHS W/ CLIENT REPRESENTATIVE PRIOR TO COMMENCING INSTALLATION.
• PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY SUITABILITY OF ANTENNA MOUNT AT SPECIFIED ELEVATION.
• IF REQUIRED, PAINT TO MATCH ANTENNAS AND ANCILLARY EQUIPMENT TO MATCH THE EXISTING STRUCTURE WITH NON -REFLECTIVE
PAINT AS REQ'D. CONTRACTOR TO VERIFY COLOR AND FINISH WITH LANDLORD AND/OR JURISDICTION.
• RETURN ALL UNUSED EQUIPMENT TO T-MOBILE WAREHOUSE.
SHEET NO.
y0t�'
ANTENNA ON (E) PIPE MOUNT (TYP `ss W
./P
�
BETA SECTOR 0OF 1 PER SECTOR, 3 TOTAL) ``��Q,Q
E
A4.0
O ?�
S
EQUIPMENT
SCALE: NTS (11X17)
SCALE: NTS (11X17)
3
FINAL ANTENNA PLAN
SCALE: NTS (22X34)
1
ANTENNA AND ANCILLARY
SCALE: NTS (22X34)
TOP
FRONT
1-
_
w
_
EPT
SIDE
ANTENNA DATA
MECHANICAL SPECIFICATIONS
MANUFACTURER
HEIGHT
WIDTH
DEPTH
WEIGHT
COMMSCOPE
72.7 IN
11.9 IN
7.1 IN
46.3 LBS
PART #
CONNECTORS
STANDARD MOUNTING HARDWARE
DBXNH-6565B-A2M
(4) 7-16 DIN FEMALE
INCLUDED
FRONT
1-
_
0
w
_
SIDE
ANTENNA DATA
MECHANICAL SPECIFICATIONS
MANUFACTURER
HEIGHT
WIDTH
DEPTH
WEIGHT
COMMSCOPE
57.0 IN
22.2 IN
4.9 IN
38.1 LBS
PART#
CONNECTORS
STANDARD MOUNTING HARDWARE
HBXX-3319DS-A2M
(4) 7-16 DIN FEMALE
INCLUDED
TOP
FRONT
WIDTH
1-
_
0
w
DEPTH
NSN FRLB LTE 700 / BAND 12 (REMOTE RADIO UNIT)
HEIGHT: 15.75"
WIDTH: 15.75"
DEPTH 5.9"
WEIGHT: 59.52 LBS
SIDE
1
ANTENNA DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
2
ANTENNA DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
3
FRIG (RRU) DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
TOP
FRONT
WIDTH
1-
w
_
fEPTHT
NOIUA FXFC (REMOTE RADIO UNIT)
HEIGHT: 19.3"
WIDTH: 22.0"
DEPTH 5.2"
WEIGHT: 55.0 LBS
SIDE
TOP
FRONT
WIDTH
ECC1920-VPUB (DIPLEXER)
HEIGHT: 7.6"
WIDTH: 7.3"
DEPTH 2.6"
WEIGHT: 7.9 LBS
SIDE
RECEIVED
DEC 112015
Community
Development Lis% Q O f
4
FXFC (RRU) DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
6
DIPLEXER DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
7
NOT USED
SCALE: NTS (11X17)
SCALE: NTS (22X34)
°
T. ° 'Mobile
4CENTERLINE
Aolhcbq WailmAYMabl
*ECTOR
e;-
+ ' CV
AL
P
.'M
[ T y
•
°.,' o
11/12/15 EXP. 1/27/16
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMN TAL
NO.
DATE
D/C
DESCRIPTION
1
11-11-15
MS/MS
BP SUBMITTAL _
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
SHEET TITLE
ANTENNA AND
EQUIPMENT
DETAILS
SHEET NO.
A5.0
NOTES:
- SUITABILITY OF PLATFORM / MOUNT(S) FOR FINAL
LOADING CONFIGURATION TO BE VERIFIED BY OTHERS
PRIOR TO INSTALLATION.
NO WORK SHALL COMMENCE WITHOUT THE
APPROVED STRUCTURAL TOWER / ANTENNA / MOUNT
ANALYSIS REPORT (SIGNED AND SEALED) TO BE
PROVIDED UNDER SEPARATE COVER. CONTRACTOR
PRIOR TO CONSTRUCTION SHALL REVIEW THE
APPROVED TOWER / ANTENNA / MOUNT ANALYSIS
REPORT SUPPLIED BY T-MOBILE AND MODIFY, IF
REQUIRED, ALL APPLICABLE MEMBERS AS INDICATED
IN CERTIFIED STRUCTURAL REPORT PRIOR TO
INSTALLATION ON STRUCTURE.
(N) T-MOBILE FRIG MOUNTED BEHIND
ANTENNA ON (E) PIPE MOUNT (TYP
OF 1 PER SECTOR, 3 TOTAL)
(N) T-MOBILE PANEL ANTENNA (TYP OF 1)
MOUNTED ON (N) WALL PIPE MOUNTS
(N) T-MOBILE DIPLEXER (TYP
OF 3) TO BE MOUNTED
BEHIND (N) ANTENNA
(N) 3" STD. MIN.
ANTENNA PIPE
(2) (N) VALMONT PART #WWM01 OR APPROVED
EQUAL STANDOFF BRACKETS OR (E)
MICROWAVE TOWER SERVICE PART #M222
ADJUSTABLE WALL MOUNTS WITH (4) 1/2"
ALL -THREAD RODS W/ 4" MIN. EMBED., W/
SIMPSON "EPDXY -TIE" GROUT, TYP. TOP AND
BOTTOM
(E) MIN. 10" THICK CONCRETE WALL
(VERIFY)
2
NOT USED
SCALE: NTS (11X17)
SCALE: NTS (22X34)
L/5Oa5 7
RECEVED
DEC 112015
Community
Development
1
ANTENNA MOUNTING DETAIL
SCALE: NTS (11X17)
SCALE: NTS (22X34)
3 NOT USED
SCALE: NTS (11X17)
SCALE: NTS (22)(34)
ob11e
-
®®
,< ►CENTERLINE
Advancing Mikes N tNatb
ECTOR
■ n • I It ■ ■ R •
11/12/15 EXP. 1/27/16
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
1
11-11-15
MS/MS
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
SHEET TITLE
CONSTRUCTION
DETAILS
SHEET NO.
A6.0
•
RFDS V. 7 - SECTOR SPLIT
Alpha & Bea (Only Alpha Is shcwn)
NSN Configuration 705J (N_705JRUSh 4spiit 012) u21a0 vat Split — 2015
4-paw paw SAeS eo h Koot l op ,t -_U ...:ont epusu& t't:S Sp.ctnsrr, Fit;;
.Nava! Split to Support LT! Spectrum m=15 MHZ
1 Fod o Monde pe+r aac:or
iA•.bm.a vd....y Aw».+w iuxm n6 `m z. w;run d,ns
r-__.•
I'--1--
:w A1•.3 •.n"" m • rv,».Jxr-0
NOTES:
1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED.
2. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY.
3. TAGGING:
m ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO
INDICATE THE ANTENNA SECTOR.
• COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE
AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE.
(NOT TO INTERFERE WITH WATERPROOFING.)
4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY
3'-0" ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS
REQUIRED TO MEET THIS REQUIREMENT.
5. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO
OVERLAP MOVES WATER AWAY FROM CONNECTION (SEE STEP 4).
6. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR QUAD POLES & TMAS.
7. ALL ANTENNAS & COAXIAL ANTENNA CABLE TO BE FURNISHED BY
T-MOBILE AND INSTALLED BY CONTRACTOR.
8. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1"
WIDE WEATHERPROOF COLORED VINYL TAPE AT THE FOLLOWING
LOCATIONS:
#1 - AT ANTENNA CONNECTION
#2 -AT ENTRY TO EQUIPMENT CABINET
9. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK & 12" FROM EDGE OF
EQUIPMENT CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE),
UP TO TOWER LEG (IF APPLICABLE), AND DISTRIBUTE TO EACH
ANTENNA DEVICE. FURNISH AND INSTALL A MINIMUM OF (3) GROUND
KITS PER COAXIAL CABLE. VERIFY NUMBER OF ANTENNAS, CABLE, AND
CABLE DIAMETER WITH T-MOBILE CONSTRUCTION MANAGER.
RECFiVED
DEC 112015
Community
Development
1
RF DETAILS - ANTENNA & ANCILLARY EQUIPMENT PLUMBING DIAGRAM
T —Mobile
<>CENTERLINE
*heady Maims Mao&
)\f
s n e i n e s R s
' a F
.'
A .
11/12/15 EXP. 1/27/16
CPM PROJECT NO.: 8856
PRELIMINARY
NO.
DATE
D/C
DESCRIPTION
0
10-22-15
MS/MS
90% CD REVIEW
1
11-11-15
MS/MS
CLIENT COMMENT
SUBMITTAL
NO.
DATE
D/C
DESCRIPTION
1
11-11-15
MS/MS
BP SUBMITTAL
SITE NAME:
SOUTHCENTER
PLACE
SITE ID:
SE04000B
SITE ADDRESS:
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
SHEET TITLE
RF DETAILS
SHEET NO.
RF1.0