Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D19-0019 - TRAPPERS SUSHI - INTERIOR TENANT IMPROVEMENT
TRAPPERS SUSHI 468 SOUTHCENTER MALL 019-0019 Parcel No: Address: City of Tukwila Department mfCommunity Development 6]VVSoouhcenterBoulevard, Suite #100 Tukwila, Washington 98z28 Phone: 206'431'3670 Inspection Request Line: 2.06'438'9350 Web site: http://www.TukwilaWA.gov 9202470010 Project Name: TRAPPERSSUSHI DEVELOPMENT PERMIT Permit Number; D19-00I9 Issue Date: 3/12/2019 Permit Expires On: 9/8/2019 Owner: Name: WESTFIELD PROPERTY TAX DEPT POBOX B0940,CARLSBAD,OR, 92013 Contact Person: Name: GLEN MILLER Phone: (503)636'7979 Address: 14lDEL PRAQ0'LAKE USWEG[\OR, 97O]5 Contractor: Name: Address: E MPRECISION LLC POBOX l266'SUK8NER,WA, 98390 License No: EMPREL*981LO Lender: Name: TRAPPERS SUSHI Address: 718GRIFFIN AVE #94O'ENU&8CLAVY WA, 98022 Expiration Date: 7/22/2020 DESCRIPTION OF WORK: IINTERIOR TI: FOR A NEW SUSHI RESTAURANT AT WESTFIELD MALL. PREVIOUS TENANT WAS A SUSHI RESTAURANT- NO CHANGE OF USE. EXISTING MECHANICAL EQUIPMENT TO REMAIN. THE NEW SPACE WILL COMBINE WITH ASMALL ADJACENT SPACE, WHICH WAS ALSO A FOOD ESTABLISHMENT. WORK INCLUDES PLUMBING, SOME MECHANICAL, ELECTRICAL FURNISHINGS, AND FINISH WORK, Project Valuation: $250000.00 Type ofFire Protection: Sprinklers: YES Fire Alarm: YES Type o(Construction: 1113 Electrical Service Provided by: TUKWILA Fees Collected: $4,856.90 Occupancy per IBC: A-2 Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: international Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: VVA[Z96'46B: Code: Public Works Acivides:� [hanne|ization/Strip|ng: [urbCvt/Acces$Sidewo|k: Fire Loop Hydrant: Flood Control Zone: Hau|ing/0versisLoad: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: StormDrainage� Street Use: Water Main Extension: Water Meter: Vo|umesi Cut: U Fill: 0 Number O No Permit Center Authorized Signature: ��\�� Date: a '�— / / [ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting ofthis permit does not presume togive authority toviolate orcancel the provisions ofany other state orlocal laws regulating construcb the performance nfwork. |amauthorized tosign and obtain this development etoth�440n5attached tothis permit. +/� Signature:,—�~=~r'_����' � Date: �» ��/ / /'/ This permit shall become null and void if the work bnot commenced within l8Vdays for the date ofissuance, orif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT DDNDOODNS*^* 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE7,Chapter 13. 5: Partition walls shall not be tied to suspended ceiling grid. All partitions greater than Gfeet in height shall belaterally braced tothe building structure. Such bracing shall beindependent nfany ceiling splay hradng. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior toopening ordoing any food processing. Arrangements for final Health Department inspection shall bemade bycalling Seattle/King County Department ofPublic Health, (l'800']2S'61G5ext9'566)'atleast three working days prior todesired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 8: All rack storage requires aseparate permit issued through the City ofTukwila Permit Center, Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by registered professional engineer licensed inthe State ufWashington. Periodic special inspection i»required during anchorage ofstorage racks 8feet o/greater |nheight. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector, No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion ofthis requirement. Il: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (ZO643l'367O). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. l]: VALIDITY UFPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila, Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ufapermit based nnconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (200/431'367O). 15: ***PUBLIC WORKS PERMIT CONDITIONS' 16: Tmper's Sushi shall connect their grease line toanoutside grease interceptor, ifone Exists, otherwise new outside tee compartment/double baffle grease interceptor shall he installed. 17: Tmper'5 Sushi shall connect their grease line to an outside grease interceptor, if one Exists, otherwise a new outside tree compartment/doub|e baffle grease interceptor shall be installed. Zl: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated atone extinguisher for each l'SO0sq. ft. ufarea. The extinguishe,(s)should beofthe "All Purpose" (3A,4O8:[)dry chemical type. Travel distance tnany fire extinguisher must be7S'orless. (|F[ 906.3) (NFPA 10\ 5.4) 22: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (|F[904.lZ.5) lQ: Portable fire extinguishers, not housed incabinets, shall beinstalled onthe hangers orbrackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having agross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top isnot more than l5feet (lO67mnn)above the floor, The clearance between the floor and the bottom ofthe installed hand-held extinguishers shall not beless than 4inches (lO2mm). (|F[9D6Jand |F[ 9015.9) 19: Extinguishers shall belocated incnnsp|cunus|ocadonsvvheradheyviUhereadilyacccssib|eand immediately available for use. These locations shall bealong normal paths oftravel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (|FC9O§,5) 20; Fire extinguishers require monthly and yearly inspections, They must have otag orlabel securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service, Every six years stored pressure extinguishers shall beemptied and 5ubjectedtntheapp|icab|eecharQeprncedu/es. |fthe required monthly and yearly inspections ofthe fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys, (NFPA 10, 7.2, 7.3) 23: Egress doors shall bereadily openab|efrom the egress side without the use ofakey orspecial knowledge 24: Exit hardware and marking shall meet the requirements ofthe International Fire Code. (|F[Chapter 10 25: Door handles, pulls, latches, locks and other operating devices ondoors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist tnoperate. (|F[1010.1.9.l) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direcUon of egress travel, Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever isless, from the nearest visible exit sign. (|FC1OlIl) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes ofthe letters not less than O7S inch (19.lmm)wide. The word "EXO`'shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not beless than O375inch (9.5mm). Signs larger than the minimum established in the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means borisnot energized. |fonarrow isprovided aspart ofthe exit sign, the construction shall besuch that the arrow direction cannot bereadily changed. (|F[101I6.l) 28: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit hardware. (|F[1O10llO) 29: Exit signs shall beilluminated otall times. Toensure continued illumination for aduration ofnot less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (|FC1013.63) 30: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (/F[1O043) 31: Emergency lighting facilities shall bearranged toprovide initial illumination that batleast anaverage ofl foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress atfloor level. Illumination levels shall bepermitted todecline tn0.6foot-candle (6lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (|FClO0D.I5) 35: Fire protection syaemsshaUbemainta/nedinacuurdancewiththeor|gina|inmaUabongmndardsforthat system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building isaltered, remodeled oradded to. Alterations tofire protection systems shall bedone inaccordance with applicable standards. (|F[90l.4) 33: Sprinklers shall be. installed under fixed obstructions over 4feet (I.Zm)wide. (NFPAl3-8.5J.].3) 32: All new sprinkler systems and all modifications toexisting sprinkler systems shall have fire department review and approval cfdrawings prior tninstallation ormodification. New sprinkler systems and all modifications tnsprinkler systems involving more than 50heads shall have the written approval nfFactory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior tnsubmittal tothe Tukwila Fire Prevention Bureau. Nosprinkler work shall commence without approved drawings. (City Ordinance No. 243Q. 36: Afire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A.7Zand City Ordinance #Z437. 38: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 37: All new fire alarm systems ormodifications toexisting systems shall have the written approval ofThe Tukwila Fire Prevention Bureau, Nowork shall commence until afire department permit has been obtained. (City C*dinance#Z437)(|FC9Dl2) 39: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 40: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. 42: Post address onstorefront per approved Westfield standards. 41: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth inTable No. 8O3.l1ofthe International Building Code. 43: In other than Group 1-3, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.4 and shall not exceed 10 percent ofthe specific waUorceiling area tmwhich they are attached. (|F[OO7.1) Where required toexhibit improved fire performance, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall be tested by an approved agency and'meet the flame propagation performance criteria ofTest Method lorTest Method 2'asappropriate, ofNFPA7O1or exhibit a maximum rate of heat release of 100 kW when tested in accordance with NFPA 289, using the 20 mNignition source. Reports of test results shall be prepared in accordance with the test method used and furnished tothe fire code official upon request, (|F[QO7.4) 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #Z436and #2437) 44: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ofsuch condition orviolation. 45: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at(2O6)575'44U7. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)4]8'935O 1700 8U|LD|NGF|NAL** 0611 EMERGENCY LIGHTING I400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUN1BOARD 0406 SUSPENDED CEILING CITY OF TUKW4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building PerPt Nu. Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 468 Southcenter Parkway King Co Assessor's Tax No.: 262304-9023 Suite Number: Floor: Ground Tenant Name: Trapper's Sushi PROPERTY OWNER Name: Unibail-Rodamco-Westfield Address: 4905 Old Orchard Ctr. Ste. 060 City: Skokie State: IL ZiP: 60077 CONTACT PERSON — person receiving all project communication Name: Glen Miller Address: 141 Del Prado City: Lake Oswego State: OR Zip: 97035 Phone: 5036367979 Fax: 5036369898 Email: glen@gamillerarchitecture.com GENERAL CONTRACTOR INFORMATION Company Name: EM Precision Construction Address: 1011 East Main Suite 205B City: Puyallup State: WA Zip: 98372 Phone: 2536910555 Fax: Contr Reg No.: EmpRELx9 0 Exp Date: 07/22/20 Tukwila Business License No.: BUS-0998851 New Tenant: 121 Yes 11 ..No ARCHITECT OF RECORD Company Name: GA Miller Architecture Architect Name: Glen Miller Address: 141 Del Prado City: Lake Oswego State: OR Zip: 97035 Phone: 5036367979 Fax: 5036369898 Email: glen@gamillerarchitecture.com ENGINEER OF RECORD Company Name: N/A Consultant used only. Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: 1 ( .---,,,‘ G v K •rtlet— * ici0 City: 0:4 State: a, q Zip: HAApplicationsWorms-Applications On Line \ 20H ApplicationslPermit Application Revised - 8-9,11.docx Revised: August 2011 hh Page 1 of 4 BUILDING PERMIT INFORMATIO106-431-3670 Valuation of Project (contractor's bid price): $ 250000.00 Describe the scope of work (please provide detailed information): Interior Tenant Improvement for a new Sushi Restaurant at Westfield Mall. Previous tenant was a Sushi Restaurant - no change of use. Existing Mechanical Equipment to remain. The new space will combine with a small adjacent space, which was also a food es- tablishment. Work includes plumbing, some mechanical, electrical, furnishings, and finish work. Will there be new rack storage? Existing Building Valuation: $ ..Yes O.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Belo Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I51 Floor 5715 5715 0 0 II-B A-2 2na Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes Q....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: QZ Sprinklers m Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of naterials and storage locations on a separate 8-1/2 " x 11 " paper including quantities and Material Sa ty Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications\Forms-Applications 4n Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 hh Page 2 of 4 PUBLIC WORKS PERMIT INFOr ATION — 206-433-0179 Scope of Work (please provide detailed information): Interior T.I. - no public works construction anticipated. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ...Tukwila El...Water District #125 0 ...Water Availability Provided Sewer District ...Tukwila 0 ...Sewer Use Certificate Highline 0 ...Valley View .. Renton D ...Sewer Availability Provided D .. Renton .. Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): Ej ...Civil Plans (Maximum Paper Size — 22" x 34") E] ...Technical Information Report (Storm Drainage) 0 ...Bond 0 Insurance 111 Easement(s) Proposed Activities (mark boxes that apply): D ...Right-of-way Use - Nonprofit for less than 72 hours El ...Right-of-way Use - No Disturbance ..• .Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 0 ...Total Cut 0 ...Total Fill cubic yards cubic yards [1] ...Sanitary Side Sewer 0 ...Cap or Remove Utilities 0 ...Frontage Improvements ..• .Traffic Control ..• .Backflow Prevention - Fire Protection Irrigation Domestic Water .. Geotechnical Report .. Maintenance Agreement(s) 0 ...Traffic Impact Analysis 0 ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) .. • Right-of-way Use - Profit for less than 72 hours .. • Right-of-way Use — Potential Disturbance .. Work in Flood Zone .. Storm Drainage .. Abandon Septic Tank .. Curb Cut 0 „Pavement Cut LI .. Looped Fire Line 0 ...Permanent Water Meter Size... EJ ...Temporary Water Meter Size .. El ...Water Only Meter Size El ...Sewer Main Extension Public ...Water Main Extension Public I=1 El WO # WO # WO # Private Private .. Grease Interceptor Channelizatlon .. • Trench Excavation .. • Utility Undagrounding 0 ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day "felephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip 1-1:1Applications \ Forms -Applications On Line12011 ApplieetionsWermit Application Revised - 8-9-11.docx Revised: August 201 1 hh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all Gases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Perrnit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF TH ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN1.2,OR Signature: Print Name: c .1'1,s ck.r Mailing Address: —1( T d$d Date: ..-1-gt 1 Le) tct Day Telephone: Z S-3 z,9 ud 64 City af State Zip HAApplications \Forms -Applications On Line \ 20H ApplicationstPermit Application Revised - 8-9-11.doex Revise& August 2011 htt Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY I PAID $3,009.45 D19-0019 Address: 468 SOUTHCENTER MALL Apn: 9202470010 $3,009.45 DEVELOPMENT $2,867,33 PERMIT FEE R000.322.100.00.00 0,00 $2,842.33 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $142.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17144 R000.322.900.04.00 0.00 $142.12 $30009.45 Date Paid: Tuesday, March 12, 2019 Paid By: TRAPPERS SUSHI CO TUKWILA Pay Method: CHECK 2002 Printed: Tuesd,ay, March 3.2, 2019 11:27 AM 1 of 1 DESCRIPTIONS Perrr itTRAK Cash Register Receipt City of Tukwila ACCOUNT D19-0019 Address: 468 SOUTHCENTER MALL Apn: 9202470010 DEVELOPMENT PLAN CHECK FEE TOT7L. FEES PAID BY RECEIPT: R16523 R000.345.830.00.00 QUANTITY $1,847.51 $1,847.51 ,847.51 0.00 51,847.51 $1,847.51 Date Paid: Thursday, January 17, 2019 Paid By: TRAPPERS SUSHI CO TUKWILA Pay Method: CHECK 1512 Printed: Thursday, January 17, 2019 7:54 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit ICt Ct3I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ' 77Pher4A 54110/4/ Type o pecti n: / /A/G-- fr-Yqt Address: Date ailed: Sp cial Instructions: Date Wanted: a.m.. p.m. Requester: Phone No: Approved per applicable codes. COMMENTS: ions equired prior to approval. A -4 afei *-44 ns pecto r: 'Date: f REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit A41 &Dig INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431 -3670 Project: rC1 PLF,a,' �.'�.� Type of Insp�ec�tio : L:.�`r` n 74s ro Address: 4 tee, ictx-ci4 C "C Date Called: — Special Instructions: Date Wanted: Requester: 177/r Phone No: Z 5'3 4k7 07 f Approved per applicable codes. COMMENTS: Corrections required prior to approval. Inspecto Date; REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Dlq —00 ig PERMIT NO:, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: - Type of Inspection: Address *Date Called: i Special instructions: 'Date Wanted: a.m. p.m.i Requester: Phone No: .Approved per applicable codes. ections required prior to approval. COMMENTS: 4 4- 'pftc)V '.7 l" r if Cr Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all Al Revised July 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. ProjectTi le: Trappers Sushi - Southcenter Date 1/14/2 019 Applicant Information, Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use FILE Company Name: Mathews Consulting Company Address: P.O. Box 766 Enumclaw, WA 98022 Applicant Name: Keith Mathews Applicant Phone: 253-804-0737 Applicant Email: inbox@mathewsconsulting.com Project Description 0 New Building 0 Addition la Alteration Ea Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms, Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project 13 Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance 13 Addition is combined with existing: For interior lighting projects, include new + existing interior lighting fixture Lighting Wattage table in LTG-INT-BLD or LTG-WT-SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT Exterior lighting 13 . wattage in Proposed manage in Proposed form, Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the7-7.---"-- fixtures are replaced in others, then provide separate ompliance forms lighting power two retrofit cfor the conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. CI No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting — 50% or more of existing are replaced II 0 0 Less than 50% of existing are replaced 0 0 0 Lamp and/or ballast replacement only — existing total wattage not increased CI [3 13 _____ -----: --- 50% or more replaced - Total lighting pouter of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new 121 0 0 circuit(s) New or moved lighting panel 13 Interior space is reconfigured - luminaires unchanged or relocated CI New wiring or circuit - For interior lighting, provide required manual controls per C405,2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405,2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use ci Existing interior lighting sy comply with LPAs for the raw Identify interior spaces requirin in LTG-WT-BLD or LTG-INT-SACE use are upgraded to C405.4.2(2). Lighting Wattage table , ,tems - :. rair7g,. - .!- in sp‘ace s - - :i: pMed 1, • . :. or ,b. :,. eC GMRLIMICEpsed for nAPPROVED FEB 2 8 2019 City of Tukwila DING DIVISION RECEIVED CITY OF TIJKWILA JAN 1 7 2019 PERMIT CENTER Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms tor Commercial Buildings including R2, R3, R4 o'.er 3 stories and all RI Re%ised July 2016 Project Title: Trappers Sushi - Southcenter Date 1/14 2019 Interior Lighting System Description Remodel of existing sushi restaurant. Back of house is un changed. Interior Lighting Power Allowance Method D BuRding Area Method la Space -by -space Method Select method used in project. Interior Lighting Controls Al C405.2.1 - C405.2.8 Controls 0 C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) n Additional Efficiency Package Option — C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with th required controls per C406.4. Dwelling Unit nterior Lighting Permanently installed interior lighting fixtures in dwelling units comply 4th: 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA 0 C406.3 High Efficacy Lighting 0 Exterior Lighting System Description NA Interior Lighting - Space -By -Space Method LTG-INT-SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Reined Julv 2016 Project Title: Trappers Sushi - Southcenter , Date 1/14/2019 Calculation Area NOTES 0 0 Addition - 0 Addition stand alone + existing gil Spaces where < 50% of •Spaces where 50% of el 0 luminaires are replaced luminaires are replaced -"' For Building Department Use LPA Calculation Type 0 Standard 0 Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage Location (plan #, room #) Space Type Ceiling Height Ncirt 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Dining area: Family dining area 12 ' 3321 0 .710 2358 Food preparation 12 ' 808 0.790 638 Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY N°-rt 8 Total Area Retail Display 4129 LTG-INT-DISPLAY Allowed Watts Allowance from 2997 Proposed Lighting Wattage Location (plan #, room #) Fixture Description NOTE4, 5' 6 Number of Fixtures Watts/ Fixture NDTE 7 Watts Proposed TYPE C HIGH B AY PENDANT 34 39 1326 TYPE E SURFACE LED 6 35 210 TYPE P CUSTOM LED PENDANT 14 12 161 TYPE R 6" LED RECESSED CAN 21 9 189 Proposed Retail Disp ay Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1886 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building fighting systems, include all applicable existing Space Types and gross interior areas. • Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK Revised July 2016 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Project Title: Trappers Sushi - Southcenter Date 1/14/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken C405,2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves E2 C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies E2 C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50%-on, or serve a space eligible tor automatic 100%-on per exception C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft; Indicate toplight daylight zone areas on plans, include sq. ft.; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone E2 C405.2.5 Additional controls - Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all RI Revised July 2016 Project Title: Trappers Sushi - Southcenter Date 1/14/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes C405,2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting C405.2.5 - Item 5 Lighting for non - visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic Ii9hting control C405,2.5 - Item 7 Means of egress lighting Identity on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control E2 C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor C405,5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% E3 C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) C405.13 C408.3 Lighting system functional testing if claiming lighting system commissioning exemption provide supporting calculation; Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Trappers Sushi - Southcenter Date 1 / 14/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY C405.4.1 C405.4.1 G405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently E3 C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) E2 C405.1 Lighting in dwelling units -lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken C405.4.2,1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable E2 C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG-CHK 2016 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Trappers Sushi - Southcenter Date 1/14/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions, Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents 1 Building Department Notes MOTORS & TRANSFORMERS C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp; rpm, rated efficiency, or exception applied C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17,1/CSA 844; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time-ot-day control If "no" is selec for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist PERMIT COORD COPY d PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0019 DATE: 01/1 7/l 9 PROJECT NAME: TRAPPER'S SUSHI SITE ADDRESS: 468 SOUTHCENTER MALL X. Original Plan Submittal Response to Correction Letter # Rev sion # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division 11 Alioft Public Works IN MONO Fire Prevention Structural Planning Division Permit Coordinator w67 PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 01/22/19 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: S-�� c'✓`S Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 02/19/19 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: I2/18/7013 11c,ine Espanol Cmitact Safety & Health Claims & Insurance shington State Department of abor & Industries !Search L&I A-Z Index Help Ivlv L&I Workplace Rights Trades & Licensing E M PRECISION LLC Owner or tradesperson Principals NEMETH, TIMOTHY SCOTT, PARTNER/MEMBER MCBEE, ELI, PARTNER/MEMBER (End: 07/08/2008) Doing business as E M PRECISION LLC VVA UBI No. 602 208 155 1011 E MAIN, SUITE 205B PUYALLUP, WA 98372 253-268-0742 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EMPREL*981L0 Effective — expiration 06/20/2002— 07/22/2020 Bond WESTERN SURETY CO Bond account no. 25272270 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 06/20/2002 06/14/2002 Expiration date Until Canceled IllsuranC! Associated Industries Ins Co I $1,000,000.00 Policy no AES1053907 Received by L&I 'Effective date 07/06/2018 07/08/2018 Expiration date C7/08/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&l Tax debts Help us improve IBC 1004.3 POSTING OF OCCUPANT LOAD Every room or space that is assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. GENERAL NOTES 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH ALL STATE AND LOCAL JURISDICTIONS AND REGULATIONS, 2. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL INSPECTIONS AND TESTS REQUIRED BY ANY GOVERNMENTAL AGENCY TO IMPLEMENT THE PLANS AND EXCEPT ANY REQUIRED SPECIAL INSPECTIONS OR REPORTS, WHICH SHALL BE PAID FOR BY THE OWNER OR TENANT. 3. NEITHER THE OWNER NOR THE ARCHITECT WILL ENFORCE SAFETY MEASURES OR REGULATIONS. THE CONTRACTOR SHALL DESIGN, INSTALL, AND MAINTAIN ALL SAFETY DEVICES AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE, AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS, AND REGULATIONS. 4, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELYARRIVAL or ALL SPECIFIED FINISH MATERIALS, EQUIPMENT AND ANY OTHER MATERIALS TO BE UTILIZED ON THE PROJECT. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING WITHIN 10 DAYS Or DATE OF CON- TRACT Or THOSE SPECIFIED ITEMS THAT MAY NOT BE READILY AVAILABLE AND SUBSTITUTE ITEMS OF EQUAL QUALITY AND DESCRIPTION. IF NOTIFICATION IS NOT RECEIVED BY THE ARCHITECT, THE CONTRACTOR ACCEPTS RESPONSIBILITY FOR THE PROPER ORDERING AND FOLLOW-UP Or SPECIFIED COST To THE OWNER To INSURE AVAILABILITY OF ALL SPEC- IFIED ITEMS SO AS NOT TO CREATE A HARDSHIP ON THE OWNER NOR DELAY PROGRESS OF THE WORK 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COND- ITIONS ON THE DRAWINGS AND ON THE JOB SITE PRIOR TO EXECUTION Or ANY WOW, AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY. CONTRACTOR SHALL BE RESPONS- IBLE FOR ALL COSTS INCUIRED DUE TO HIS FAILURE TO DO $0. E.. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS 16 IN DOUBT, OR THERE APPEARS TO BE AN ERROR ON THE DRAWINGS, OR WHERE THERE 15 A DISCREPANCY BE- TWEEN THE DRAWINGS AND THE FIELD, THE ARCHITECT (AND ENGINEER WHERE APPLICABLE) SHALL ME NOTIFIED AS SOON AS PEA50NAIBLY POSSIBLE FOR PROCEDURE TO FOLLOW, DO NOT SCALE THE DRAWINGS, I. ALL REVISIONS MUST BE APPROVED IN WRITING BY BOTH THE OWNER AND THE ARCHITECT PRIOR TO THE CONSTRUC- TION OF ANY DEVIATION IN THE SCOPE OF WORK B. DIMENSIONS SHOUN ON THE PLANS AIRE To FACE 0'P FINISH, CENTER- LINES, OR GRID LINES, UNLESS OTHERWISE NOTED OR DETAILED. 'B. NO ADDITIONAL ROOF OPENINGS OR ROCP MOUNTED EQUIP- MENT IS ALLOWED BEYOND WHICH IS SHOWN ON THESE PLANS, 015 ANY) WITHOUT WRITTEN CONSENT OF THE OWNER. 10. PROVIDE FIRE EXTINGUISHERS WITH REQUIRED SIGNAGE AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR DURING CONSTRUCTION, PROVIDE A PORTABLE FIRE EXTINGUISHER WITH TYPE AEC RATING ON THE JOIESITE. M ALL EXISTING FACILITIES TO BE MAINTAINED IN -PLACE BY THE CONTRACTOR UNLESS OTHERWISE SHOWN OR DIRECTED. CON- TRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO SUF- F-ORT, MAINTAIN, OR OTHERWISE PROTECT EXISTING UTILITIES AND OTHER FACILITIES AT ALL TIMES DURING CONSTRUCTIC1,1, CON- TRACTOR SHALL LEAVE EXISTING FACILITIES IN AN EQUAL OR BETTER-THAN-CRICONDITIONAL CONDITION AND TO THE SATISFACTION OF THE ARCHITECT/OWNER. 13. REFER TO WESTFIELD MALLIS'DESIGN CRITERIA MANUAL' AVAILABLE IN THE DROF50X FOLDER FOR ADDITIONAL SPECIFICATIONS AND CRITERIA. IN CASE or CONFLICT, NOTIFY ARCHITECT SUMMARY OF WORK - INTERIOR TENANT IMPROVEMENT FOR A NEW SUSHI RESTAURANT, COMBINING TWO TENANT SPACES. BOTH TENANT SPACES WERE FOOD SERVICE, ONE BEING A SUSHI RESTAURANT, WOW INCL- UDES MODIFICATIONS TO EXISTING HVAC SYSTEM, PLUMBING, AND ELECTRICAL SYSTEMS, NEW KITCHEN EQUIPMENT, FURNITURE, FIXTURES, AND EQUIPMENT. NEW FINISHES. OCCUPANCY AND NUMBER OF EXITS REMAIN UNCHANGED. THE G.C, SHALL CONTACT THE REQUIRED PIPE ALARM 4 FIRE SPRINKLER SUB -CONTRACTORS TO PROVIDE DRAWINGS 4 SPECS. FOR THEIR RESPECTIVE PERMITS ONCE THE FRE -CONSTRUCTION MEETING 16 SCHEDULED. G.C. SHALL SUMMIT SHOP DRAWINGS FOR THE EXTERIOR SIGN(S) TO THE LANDLORD FOR REVIEW 4 APPROVAL G.C. SHALL HAVE WESTFIELD -STAMPED DRAWINGS ON SITE AT ALL TIMES AND WILL FUNCHLIST OFF Or THE WESTFIELD STAMPED DRAWINGS ONLY. 1/101la Ik,VA M M, 71 711 ml, ?_10OU-Irn"CENTER PARKWAY SOUTHICENTER MALL TUKWILA, WASHINGTON 98188 TENANT: TRAPPER'S SUSHI FEDERAL WAY dba TRAPPER'S SUSHI CO. 718 GRIFFIN AVE. #940 ENUMCLAW, WASHINGTON 98023 CONTACT: TRAPPER O'KEEFFE ARCHITECT: GA MILLER ARCHITECTURE 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 (FAX) CONTACT: GLEN MILLER RA, CSI M.E.P. ENGINEER: MATHEWS CONSULTING P.O. BOX 766 ENUMCLAW, WASHINGTON 98022 253.804.0737 CONTACT: KEITH MATHEWS INTERIOR DESIGNER: BSR BRAND + ENVIRONMENT (SEPARATE CONTRACT) 16006 88th AVENUE NE KENMORE, WASHINGTON 98028 206.856.7730 CONTACT: KEN BARNES KITCHEN CONSULTANT: CMA RESTAURANT SUPPLY & DESIGN, INC. (SEPARATE CONTRACT) 12811 NE 126th PLACE KIRKLAND, WASHINGTON 98034 206.356.8935 CONTACT: JEFF WINTER GEN. CONTRACTOR: EM PRECISION 1011 E. MAIN ST. SUITE 205B PUYALLUP, WASHINGTON 98372 253.691.0555 CONTACT: ELI McBEE SCOPE OF WORK: INTERIOR ALTERATIONS TO TWO ADJACENT TENANT SPACES WITHIN WESTNELD MALL - SOUTHCENTER. WORK SHALL INCLUDE, BUT NOT LIMITED TO: NEW NON-STRUCTURAL PARTITIONS, NEW CASEWORK, NEW LIGHTING AND EGRESS PATH OF TRAVEL, NEW FINISHES, ALTERATIONS TO PLUMBING, ELECTRICAL, HVAC, rf;m SPRINKLERS. DEFERRED SUBMITTALS THE GENERAL CONTRACTOR SHALL FILL IN THE NAME OF MANUFACTURER AND NAME OF THE STATE OF WASHINGTON REGISTERED ENGINEER (IF APPLICABLE) WHO WILL STAMP THE CALCULATIONS AND SUBMITTALS FOR THE FOLLOWING SYSTEMS TO BE DESIGNED BY THE CONTRACTOR. THIS INFORMATION SHALL BE INSERTED ON THE CLERK COUNTY PERMIT SET OF DOCUMENTS BY THE GENERAL CONTRACTOR DRAWINGS, MATERIAL SPECIFICATIONS, AND CALCULATIONS MEETING THE SPECIFIED REQUIREMENTS ARE TO ME SUBMITTED TO THE ARCHITECT FOR REVIEW AND CONFORMANCE OF DESIGN INTENT. THE ARCHITECT WILL THEN RETURN COPIES Or THE DOCUMENTS TO THE GENERAL CONTRACTOR FOR SU15MITTAL TO CLERK COUNTY FOR FINAL APPROVAL UNDER SEPARATE PERMIT. ITEM NAME OF COMPANY WASHINGTON REGISTERED ENGINEER AUTOMATIC FIRE SPRINKLER SYSTEM PIPE ALARM SYSTEM FOR FIRE SPRINKLER PP 67'4 REGISTERED ARCRIT T too W.LER STATE OF WASHINGTON A-0 COVER SHEET / VICINTY MAP A 1.1 SITE PLAN, DEMO. PLAN, EXIT DISCHARGE PLAN A 1.2 EGRESS / LIFE SAFETY PLAN, OVER-ALL BLDG. PLAN A 2.1 FLOOR PLAN, NOTES A 2.2 REFLECTED CEILING PLAN A 2.3 LIGHT FIXTURE SCHEDULE, CEILING DETAILS, DOOR SCHEDULE A 3.1 INTERIOR ELEVATIONS & DETAILS 8 1/2"x11 " SPECIFICATIONS MF 1.1 INTERIOR ELEVATIONS & DETAILS MF 1.2 INTERIOR ELEVATIONS & DETAILS MF 1.3 FINISH PLAN & ROOM FINISH SCHEDULE M-1 HVAC PLAN, DETAILS SEPARATE PERMIT WIRED FOR M-2 HVAC DETAILS, SCHEDULES MOC halkil Eleo lasPiping E-1 POWER PLAN, SCHEDULES Plumbing Gl E-2 LIGHTING PLAN, FIXTURE SCHEDULE BCRDYINoGf TukwilaIL DIVISION E-3 PANEL SCHEDULES P-1 PLUMBING PLAN, DETAILS P-2 PLUMBING RISER, DETAILS REVISIONS K-1 KITCHEN EQUIPMENT ROOF PLAN No oranges shall be made to the scope of wors vulnout prior approval of the K-2 KITCHEN EQUIPMENT SCHEDULE Tukwila Building DivisioNOTE: Revisions will reathre an new plan K-3 KITCHEN ELECTRICAL ROUGH -IN PLAN submittal and may include additional plan review. K-4 KITCHEN MECHANICAL ROUGH -IN SCHEDULE K-5 KITCHEN WALL BACKING PLAN K-6 KITCHEN ROOFTOP EQUIPMENT PLAN SUPEPVISION LOW VOLTAGE EXTERIOR 61 AGE Vl%.#INITV T M/%r ABBREVIATIONS N.T.S. W AT B.O. BY OWNER DWG. . DRAWING GEN. GENERAL LTIG. LIGHTING REV. REVERSE T 4 G TONGUE AND GROOVE ANCHOR BOLT B.O.L. BOTTOM or LINTEL C>TL. DETAIL G.I. GALVANIZED IRON LT. L GHT Rm. ROOM T.C. TOPOF CURB ACOU5T. ACOUSTIC/ACCOUSTICAL CAS. CABINET D.S. DOLLN51-OUT GL. GLASS MANUr./MFF_ MANUFACTURER R. RADIUS T.C.I. TILE COUNCIL INSTITUTE ADJ. ADJACENT CER CERAMIC OF. DOUGLAS FIR GRID. GRADE MAS. MASONRY PIP, RAIN DRAIN/ROOP DRAIN T.J, TROWEL JOINTfrOOL JOINT AGGr. AGGREGATE CHARS. CHARACTERS EA. EACH GYP. GYPSUM MAT. MATERIAL RO. ROUGH OPENING T.O.C. TOP OF CONCRETE RECEIVED ALT, ALTERNATE It CENTER LINE ELECT. ELECTRIC/ELECTRICAL G.B. GYPSUM BOARD MAX. MAXIMUM SCHEID. SCHEDULE T.O.P. TOP OF FRAMING CITY OF TUKWILA ALUM, ALUMINUM CLG. CEILING III ELEVATION/ELEVATOR GL. GLU-LAM M.D.O. MEDIUM DENSITY OVERLAID SECT, SECTION T.O.M. TOP OF MASONRY ANOD. ANODIZED CLFP_ CLEAR EQUIP. EQUIPMENT HC/HCAR HANDICAPPED MECH. MECHANICAL 6HT. SHEET T.O.P. TOP OF PARAPET )AN 17 2019 AFF, APPLICATIONS COL COLUMN EQ. EQUAL H.C. HOLLOW CORE MEMB. MEMBRANE SHT'G. SHEATHING T.P. TOILET PAPER APPROX. APPROXIMATE/ CONC. CONCRETE EXIST, EXISTING HDR. HEADER MEZZ. MEZZANINE SQ. SQUARE T.I.D. TOILET PAPER DISPENSER AFFROX MATELY COND. CONDITION EXP. EXPANSION HID. HEAD MH. MANHOLE SQ. Fit SQUARE FEET T.S. TUBE STEEL PERMIT CENTER ARCH. ARCHITECTURAL CONN. CONNECTION EXTINa EXTINGU15H/EXTINGUISHER HEX. HEXAGONAL MIN. MINIMUM aim. SIMILAR T.O.W. TOP Or WALL A5PH. ASPHALT CONST. CONSTRUCTION EXT. EXTERIOR H.C.M.0 HOLLOW CLAY MASONRY UNIT MOD. MODIFIED SPEC. SPECIFICATION UG, UNDERGROUND AUTO. AUTOMATIC CONT. CONTINUOUS E.E.S. EMERGENCY ELECTRICAL HORIZ. HORIZONTAL MTL- METAL STD. STANDARD U.B.C. UNIFORM BUILDING CODE AUX. AUXILIARY COR CORRIDOR SYSTEM HIR. HOUR NOM. NOMINAL STL. STEEL U.O.N. UNLESS OTHERWISE NOTED APP. ABOVE FINISHED FLOOR CU. CUBIC E.J. EXPANSION JOINT HT. HEIGHT NO. NUMBER 5TOR. STORAGE VEN. VENEER ANAL AMERICAN NATIONAL CPM. CUBIC FEET PER MINUTE E.W. EACH WAY H.B. POSE 511515 N.I.C. NOT IN CONTACT STRICT. STRUCTURAL VBIR`r. VERTICAL REVIEWED FOR STANDARDS INSTITUTE CA. CAST IRON FDTN. FOUNDATION HM. HOLLOW METAL OFIG. OPENING SUSF, SUSPENDED V.C.T. VINYL COMPOSITION TILE COMPLIANCE SO. BOARD Cli. CONTROL JOINT FIN. FINISH H.VA.C1 HEATING VENTILATION AND OFF.. OPPOSITE SYS. SYSTEM W/ WITH MIT. BITUMEN cm,U. CONCRETE MASONRY UNIT FIXT. FIXTURE AIR CONDITIONING O.C. ON CENTER S. AND S. STAIN AND SEAL WD. WOOD APPROVED BLDG. BUILDING CAP, COLD ROLLED rL, FLOOR IN. INCH PER'. PERFORATED S. AND V. STAIN AND VARNISH WIN. WINDOW 5LK_ / BLK'G. BLOCKING 0 OR CIA. DIAMETER FT. FOOT INSUL. INSULATION FLYW'O. PLYWOOD S.C. SAW CUT/SOLID CORE wp. WATERPROOF IBM. SEAM IDSL DOUBLE rTG. FOOTING INT. INTERIOR P.B. PARTICLE BOARD S.D. SOAP DISPENSER WT. WEIGHT FEB 2 8 2019 MOT, BOTTOM DEFT. DEPARTMENT F:E.C. FIRE EXTINGUISHER CABINET JT, JOINT IF PROPERTY LINE/PLATE am. SHEET METAL W. WIDTH 5SMIT. BASEMENT DIM, DIMENSION POP. PACE OF FINISH JST. JOIST P.T. PRESSURE TREATED S.S. STAINLESS STEEL W.G. WATER CLOSET City of Tukwila 5TWN. BETWEEN IDISR DISPENSER F.O.S. PACE CIF STUD KIT. KITCHEN P.T.D. PAPER TOWEL DISPENSER TEMP. TEMPERED LUP. WIDE FLANGE BUR BUILT-UP ROOFING ON. DOWN GALV. GALVANIZED LAM. LAMINATED REINP. REINFCf:Zr—ED/F?r=INFOf;?GING THK, THICK BUILDING DIVISION B.C. BOTTOM Or CURB OR. DOOR GA. GAUGE LAV. LAVATORY REQ. REQUIRED TYF. TYPICAL FIL y ry Permilit No. Plan review approval is subject to effors and omissions Approval ofronstruction documents does 101 allth. raze the violation of any spooled coca or ordinance Receipt of approved Field Copy and y fa GI h Data BUILDING DIVISION PROJECT LOCATION PARKING 4 SITE ACCESSIBILTr EXISTING (UNDER PREVIOUS PERMIT) - NO WOW APPLICABLE CODES BUILDING CODE: 2016 ISO WAC 51-50 AMMENDED MECHANICAL: 2015 MC WAC 51 -52 AMMENDED PLUMBING: 2015 UPC WAC CHPTRS. 51-5( . 4 51-51 AMMENDED ACCESSIBILITY: 200E ICC AIIIJ ANSI CODE FIRE CODE: 2015 IFC WAC 51-54 AMMENDED WASHINGTON STATE ENERGY CODE ZONING / MISC. DATA SCOPE OF WORK: INTERIOR TENANT IMPROVEMENT, NO EXTERIOR WORK TAX PARCEL -, 262304-9023 ZONING USE: TUKWILA URBAN CENTER PARKING: EXISTING / NA. LOWEST FIN. FLIP. ELEVATION: EXISTING / NO CHANGE OCCUPANCY CLASSIFICATION LEASE SPACE AREA: 5,1151 90. FT. i GLA (NOTC4AR4NTFXP PER WMA) 5,4521 80, FT.* NLA (NOT GUARANTEED PER WMA) PREVIOUS OCCUPANCY CLASS: WESTFIELD MALL -M- COVERED MALL PROPOSED OCCUPANCY CLASSIFICATION: A-2'- RESTAURANT CONSTRUCTION TYPE: TYPE: 11-13, FULLY SPRIW,_EFW (PER FREV. PERMIT) OCCUPANT LOAD, SACK-OF-HOLISIE/FRER: 1231 / 200 CNN* / ENTRY: 3,431 /15 = 234 RESTROOMS: 281 SP. 0 0 ANCILLARY (HALL/FER ALCOVV. 115 S.F. 0 a COOLERS: 156 / 0 = 0 (E) OFFICE: 16 SF.7 100 = 1 (E) STORAGE: eO SF.7 200 - I TOTAL: 243 OCCUPANCY SEPARATION - EACH TENANT SPACE SHALL BE SEPARATED FROM OTHER TENANT SPACES MY A FIRE PARTITION COMPLYING WITH SEC- TION 106. A FIRE RESISTANCE OF NOT LESS THAN I-HR 15 REQUIRED PER SECTION'10&-'i THE EXISTING TENANT SPACE 19 SURROUNDED BY AN EXT. WALL, AN EXISTING 1-HR. RATED CORRIDOR, AND AN EXIST'G. 1-HR DEM. WALL. MEANS OF EGRESS IF THE TENANT SPACE HAS AN OCCUPANT LOAD Or SO OR MORE, NO FEWER THAN TWO MEANS OF EGRESS SHALL BE PROVIDED (I5C SECTION 40223) NUMBER OF EXITS REQUIRED: 2 NUMBER Or EXITS PROVIDED: 2 EXISTING SECTION 402S.5. - WITH EACH INDIVIDUAL IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR ENTRANCE TO THE MALL SHALL NOT EXCEED 200 FT TRAVEL DISTANCE TO THE EXITS FROM WITHIN THE TENANT PACE 19 LESS THAN 200 FT. (OK). RESTROOM CRITERIA - OCCUPANT LOAD FACTOR SHALL BE DETERMINED BY WAC CHFTR n TOTAL OCCUPANTS: 243 121 MALES / 122 FEMALES NUMBER OF RESTROOMS REQUIRED: TWO RESTROOMS PROVIDED: TWO NUMBER OF WATER CLOSETS REQUIRED: I FOR UP TO IS MEN, I FOR UP TO IS WOMEN (TABLE 29O2.1) NUMBER PROVIDED: I . I UWAL (M), 2 (W) LAVATORIES REQV, I PER 200 FOR MEN AND WOMEN LAVATORIES PROVIDED: I EACH SEX ENERGY CODE, BLDG. ENVELOPE: NO ALTERATION PFWFOSED (BY OTHER&APREV. PERMIT) HVAC. ENERGY CODE SUMMARY PROVIDED LIGHTING: ENERGY CODE SUMMARY PROVIDED DRAF STOPPING - NOT REQUIRED; DRAPTST01-f-ING 19 NOT REQUIRED IN BUILDINGS EQUIPPED W/ AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9033A PER 15C SECTION 118.43 EXCEPTION. 7 0 Kill Flle: 1601-13 Covershest.clule Date/Time: January 14,20n 11:41 AM Scale: 1-1 Xrefe: t EXISTING 4T (� �w LOADING AREA i(RZl 7- 1 rl -1•�� yl I I� II' WJ t i lk— ��� �Yc�I.�:.uUL IL.ILU,JLpLJLWvIL.11 If1i17L1r �=,��1WJu,.luJ1 ILIILW:llL11L.nlSaLi 4a1;,fIL. Ir `>'" -�- —� RTRANI7�R `8LVD, =1 rJ 1v I i 3�; L 5. — 1 �F•— NOTE: LOCATION OF DRIVEWAYS, PAR<ING, LOADING AND SERVICES AREAS REMAIN UNCHANGED. LANDSCAPING AND IRRIGATION REMAIN UNCHANGED. i LAN - NTS XREFISD--- IR ADVANCE NOTICE PRIOR TO DEMOLITION. T TO DAMAGE OR ALTER ANY EXISTING STRUCTURAL IF ANY DAMAGE OCCURS OR IS DISCLOSED DURING SHALL BE DISCONNECTED AT SOURCE AND WORK TWO BUSINESS DAYS IN ADVANCE. SPRINKLER DRAIN )NSTRUCTION MEETING. WOUTION SUCH THAT DUST DOES NOT TRAVEL THROUGH THE MALL COMMON AREA. PRIOR TO COVERING RETURN VENTS. E ON STANDBY DURING DEMOLITION. SARY. CONTACT FACILITIES FOR MALL TILES. REFER TO PIER PAINT SPEC. "H TC AND MALL FACILITIES PRIOR TO. ANY NEW WORK rH MALL FACILITIES PRIOR TO INSTALLING NEW CEILING. THE BASE. BUILDING'; OR ADJACENT t TC APPROVAL REQUIREDPRIOR TO BARRICADE TAKE DOWN. TENANT GC TO SCHEDULE PRELIMINARY C WITH WESTFIELD TO ONE WEEK PRIOR TO SCHEDULED BARRICADE TAKE DOWN. NOTE: G.C. IS RESPONSIBLE FOR FIELD VERIFYING ALL DIMENSIONS, COLUMN LOCATIONS, AND CONDITIONS PRIOR TO ANY WORK NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO ANY. UJORK FOR - EXISTING WALL OR PARTITION TO REMAIN I EXISTING STOREFRONT TO REMAIN EXISTING STOREFRONT TO BE REMOVED o _ _= EXISTING DOOR TO REMAIN =E-I r EXISTING DOOR TO REMAIN DEMOLITION PLAN GENERAL NOTESLJ 1. REMOVE AND DISPOSE OF ALL .EXISTING FLOORING AND BASE U.ON. �I U u Z PROTECT ALL ADJACENT AREAS DURING DEMOLITION FROM DUST d TRASH INTRUSION. U i 3. VERIFY WITH OWNER RE -USE OR SALVAGE OF ALL FURNITURE, FIXTURES, d EQUIP. PRIOR TO DEMOLITION WORD. REVIEW ON SITE IF POSSIBLE. E 4. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND CONFIRM ALL EXISTING CONDITIONS AND VERIFY ALL WORK SCHEDULED FOR DEMOLITION OR TO REMAIN, AND NOTIFY THE ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK 5. VERIFY ALL UTILITY CONNECTIONS AND LOCATIONS PRIOR TO ANY DEMOLITION WOW, - - ---------------- - - 6. DO NOT DEMO OR REMOVE ANY EXISTING ELECTRICAL PANELS, TRANS- EL 5 FORMERS, FIRE PANELS, OR EMERGENCY LIGHTING U.O.N. PLUMBING DEMOLITION NOTES 1. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND MAKE ADJUSTMENTS AT NO ADDITICNALCOST TO THE OWNER. 2. ALL WOR< SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE JURIS- 2 y DICTION AND LOCAL CODES. d 3. PROVIDE ACCESS PANELS AS NEEDED TO ACCESS VALVES, EQUIPMENT, ETC. II LOCATED ABOVE GYP. MO. OR OTHER INACCESSIBLE CEILINGS. _-__� 4. PROVIDE GLEAN -OUTS AS NEEDED TO ACCESS SANITARY SEWER LINES, ETC. LOCATED AS VERIFIED. IN FIELD 5. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL NOTES, SP£GS., d O. DEMOLITION PLAN LEGEND NOTES - ---- - ❑1 PROVIDE EXTERIOR BARRIER FOR EXTERIOR WALL/DOOR CONSTRUCTION -- ❑2 L.L. CONTRACTOR SHALL REMOVE EXIST-G. FLOOR FINISHES 4. GRIND CONIC. 3 TYP ❑3 L.L. CONTRACTOR SHALL GRIND OONC. WHERE WALLS WERE REMOVED.. LL. CONTRACTOR SHALL REMOVE THE EXIST'G. SUSHI SYSTEM d RELATED �� —U - --r•------'-- '-------------- £QUIP. INCL. THE CONC. CURB, PLUMBING, ELEC. AS REO'ID. AND CAP OFF ® AND LEAVE IN A SAFE, COPE COMPLIANT CONDITION, INCLUDING GRINDING L L,' I a �.- CONC. AS REQUIRED. 5 ALL R£Q'p. COUNTERTOP d BOOTH DEMOLITION DUE TO THJT F ❑© 'L__------ ---- 1 F - ❑ THE CONVEYOR SYSTEM 15 THE RESPONSIBILITY OF THE TE===J ( I 6 L.L.CONTRACTOR SHALL REMOVE ALL EXIST'G. PLUMBING FIXT9 FLOODEMO ALL CEILINGS; FIXTU S, FLOORING, ETC. THIS TENA SPAG£L.L. CONTRACTOR CAP OFF ANY PLUMBINGIELEC. THAT IS REXCEP7 7RANSFORM£R d EC. PANELSLJ THE REMOVAL OF EXIST'G. CASEWORK -U.ON.LL. CONTRACTOR SHALL REMOVE EXISTG DECORATIVE LATTICE ® STOREXIST'G, REST RMS. ❑9 L.L. CONTRACTOR SHALL REMOVE ALL EXTERIOR SIGNAGE TO REMAIN, SEE M-F DWIsS. FOR NEW FINISHES I ( I I II I I EMTRANCE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 8 2019 City of Tukwila BUILDING DIVISION CITY OF TUKWILA JAN 17 2019 PERMIT CENTER '/�*NXHI151017 AW i (FOR REFERENCE ONLY) 4 X ( H L.AN SCALE: AS SHOWN XREF(S):--- N ALI NTS XREPCSh-- y All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. � M . A 13111 'N1 o o -0A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX glen©gami I lerarchttecture.com CONSULTANTS MATHEWS CONSULTING GENERAL, CONTRACTOR, EM PRECISION PUYALLUP, WASHINGTON y TRAPPER'S SUSHI T,I, SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. PP ii e SVSIAl1 CO i-II-19 LL. COMMENTS - ADDEND: N 12-14-IS LL. REVIEW MARK DATE I DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 Al-1 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 © w right 2013 GA MILLER ARCHITECTURE SHEET TITLE SITE PLAN, DEMO. PLAN, EXIT DISCHARGE DWG. ■ SHEET OF File: 1801-13 AM Site Plan - Demo Plan Exit Plandwg Date/Time: January 11, 201S 5:05 PM Scale: k4a Xrefs: IMeTAMIM TRAVEL SEE EGRESS NOTE "2 BELOOF ®■■®®®®assl® EGRESS EXIT PATH EMERGENCY / EXIT COMBO LIGHT FIXTURE - NEW OR EX16T'a SEE EGRESS NOTE " 2 AND R.C.P. (TYP.) NEW OR EXISTING (VERIFY) TACTILE ES EXIT SIGN PICTOGRAM IN ACCORD- �.• ANCE WITH [CC ANSI 4111.1 SECTION 103 CODE OCCUPANCY: L SEE COVER SHEET FOR PROJECT AREAS AND TOTAL OCCUPANCY, 2. OCCUPANCY GROUP: A-2, RESTAURANT GENERAL NOTES I. THE TENANT SPACE CURRENTLY HAS FIRE SPRINKLER PROTECTION. THE CONTRACTOR SHALL MODIFY AS NEEDED TO ACCOMODAT£ THE NEW DESIGN LAYOUT TO CONFORM WITH NFPA 13 SPRINKLER REQUIREMENTS. 2. POST MAX. OCCUPANT LOAD SIGNAGE INSIDE THE FRONT DOOR WITH A PERMANENT SIGN IN ACCORDANCE WITH STATE AND LOCAL CODES AND REQUIREMENTS, 3. REFER TO LIGHTING PLAN, REFLECTED CEILING PLAN, AND LIGHT FIXTURE SCHEDULES FOR ADDITIONAL LOCA- TIONS OF EXIT LIGHTS, EMERGENCY LIGHTING NOTES, AND SPECIFICATIONS. EGRESS NOTES 1. IF NOT EXISTING, PROVIDE EMI EMERGENCY ELECTRICAL SYSTEM THAT SHALL AUTOMATICALLY ILLUMINATE EXTERIOR LANDINGS FOR EXIT DOORWAYS AND EXIT PASSAGEWAYS IN ACCORDANCE WITH IBC SECTION 1006. PROVIDE I F.G. MIN. AT LANDING AND FLOOR 5URFAC£S. THE SYSTEM OR FIXTURE SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN SO MINUTES AND SHALL CON515T OF STORAGE BATTERIES OR UNIT EQUIPMENT. THE INSTALL- ATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH IBC SECTION 2102. THE FIXTURES MUST BE U.L. RATED FOR DAMP LOCATIONS 2, PROVIDE I F.G. MIN. ILLUMINATION AT EGRESS PATH OF TRAVEL AS SHOWN AND AT EXIT DOORS. SEE LIGHT FIXTURE SCHEDULES FOR EMERGENCY/EXIT FIXTURE SPECIFICATIONS. 3. SEE LIGHTING PLAN 4 SCHEDULE FOR NEW OR EXISTING LIGHTING ON SEPARATE CIRCUIT AND SEPARATE BATTERY/ INVERTER SYSTEM FOR EGRESS LIGHTING. 01L.Ir-rm TYt/4"-1'-O" XREF(5):1801-13 BASE File: 1801-13 Al2 Life Safety -Egress Plan.dwg Dats,Mme: January 10, 20M 4:52 PM Scale: 1.48. Xrefs: Is EXIT TO IN z0 UJ z O Z 0 O O O 0 0 <t LU i 2 Cn LU z W O FL v Z U)LU w ILU ai BACF EXISTING STORAGE EF Q___D Q___D EXISTING OFFICE DINING 1 i ■ �.— --- -- Is I__ II ■ Is V ■ /' II ■ I zm WOMEN �e All concepts, aeslgns, arrangements, ano aata matcatea on these aocuments are the p developed for use cm, and In connection with the specified project. None of such Ide any person, firm,or corporation for any purpose whatsoever without permission of G. A. Miller - LOCKED LIQUOR - STORAGE BEER COOLER NOT A FIRE EXIT ` OUTDOOR PATIO LIQUOR BAR®®ao®®a®®®a®am FI m i Q� ® J. �d m ■ x DINING y IN 4-4 _ ■ ■ m ® SEE NOTE." I THIS _ .------- _J •�® SHEET TO ■ ■ set ■ ■ ■ ® cps®a®a®®®sas■ ■sash ■ ■ ■ ■ I Is ® m _ C7 _______ DININGIs _Z ------ Is ■ ------- Is ■ (Y I EF --------1 I v m Z ■ _ m ■ m O I Is U ■ ■ Is ■ Is ------- �aam®a®aaaeaaa■®®®®u ■■soa, ®a®aa®se®aa®� ----- - Is Is --- - - ■ — -- — --- RECER LJ CITY OF TU JAN P z 3. A. Miller Architecture and were created, evolved, and arrangements, or data shall be used by, or disclosed to 8 A M A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX g leno gams I lerarchltecture.com CON81.11 NT8 MATHEWS CONSULTING GENERAL CONTRACTOR, EM PRECISION PUYALLUP, WASHINGTON GISTERREGISTERED RC41T T V RE TATE TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. *NPPIN SUSIAI CC 12-14-18 Ll.. REVIEW MARK DATE DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 At-2 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 @ copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE 9 APPROVED FEB 2 8 2019 City of Tukwila ESS PLAN m SHEET or - PLAN LEGEND EXISTING WALL OR PARTITION TO REMAIN EX15TING STOREFRONT TO REMAIN EXISTING STOREFRONT TO BE REMOVED NEW PARTITION OR W,4LL NOTE LEGEND: REMOVE EXIST-G. STOREFRONT GLAZING * MULLIONS, INSTALL NEW ALUM. STOREFRONT DOOR ❑(MATCH EXISTING DRS.) 4 INSTALL NEW TEMPERED GLAZING EA. SIDE Or DOOR. SEE DOOR SCHEDULE AND SPECS. SEE COVERSHEET 4 DR SCHEDULE FOR ENERGY CODE SPECS. REMOVE EXISTING STOREFRONT AND ENTRY DOORS 4 RE -USE IF POSSIBLE AT NEW LOCATION SHOWN ON ❑PLANS. INSTALL NEW STOREFRONT WINDOW SYSTEM IN ALIGNMENT WITH EXISTING STOREFRONT AS SHOWN. MATCH ADJACE GLAZING TYPE. ALL NEW GLAZING SHALL BE TEMPERED. EXISTING AAA. COMPLIANT RESTROOM 4 ACCESSORIES ❑ TO REMAIN. SEE M-F DUr.S. FOR NEW FINISHES. EXISTING BABY -CHANGING STATION TO REMAIN EXISTING COLUMN / COLUMN WRAP TO REMAIN. SEE M-F D16.5. FOR NEW FINISHES, TYP. REPLACE EXISTING STOREFRONT GLASS PANEL F6-1 WITH TEMPERED GLASS (THIS SECTION), IF NOT ALREADY 7 TEMPERED (FIELD VERIFY) HOSTESS STATION, SERVER STATIONS, BANQUETTE F71 DESIGN, MILLWORK, AND CASEWORK DESIGN 4 DETAILING BY OTHERS. REFER TO M-F DRAWINGS. EXISTING ELECTRICAL PANELS - SEE ELECVL. DUr's, EXISTING TRANSFORMER - SEE ELEr--r'L. DLLGS. 101 EXISTING SIEMENS LP -28' PANEL - SEE ELECT'L. 011r.S. [111 42' HIGH PONY WALL W/ 12' WIRE MESH FRAME ATOP. SEE MF DX�S. g &V HIGH PONY WALL W1 24' FROSTE GLASS ATOP, SEE mr Dwa. R13 55' HIGH PONY WALL ill/ 12' WIRE MESH FRAME ATOP. SEE MF DliGs. H FRAME/FINISH 2' GAP I5TWN. COOLER 4 (E) DEM. WALL GENERAL CONTRACTOR NOTES L THE G.C. -'WALL VERIFY AND REFER TO DESIGNER (M-r) DRAWINGS FOR ALL DECOR, ARTWORK, MILLWORK, EAR DIE FURNITURE, ETC. PRIOR TO COMMENCING ANY WORK- REFER TO M-F DRAWINGS FOR FPE. DIMENSIONS, AND NOTIFY THE ARCHITECT AND DESIGNER Or ANY CONFLICTS PRIOR TO COMMENCING WITH ANY WORK. 2. VERIFY ALL SPEAKER AND LOW VOLTAGE EQUIPMENT 4 C6 LOCATIONS, POWER REQUIREMENTS, ETC. WITH OWNER PRIOR TO ANY WORK. 3. REFER TO THE COVER SHEET FOR ADDITIONAL GENERAL NOTES INCLUDING NOTES ON FIRE EXTINGUISHERS. 4, REFER To M-F PUrS& FOR ALL FURNITURE 4 FINISHES U.ON. 5, G.C. SHALL VERIFY ANY AND ALL NEW ELECJDATA OUT- LET LOCATIONS IN FIELD WITH TENANT PRIOR TO BID. HEALTH DEPARTMENT NOTES 1. HEALTH DEPARTMENT INSPECTION 19 REQUIRED PRIOR TO OPENING. 2. NO CHANGES SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM THE LOCAL HEALTH DEPARTMENT. 3. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR ALL NEW FLOOR DRAIN AND I.D. LOCATIONS *Separate Mechanical Permit shall be required for: Coolers, freezers, walk-in coolers and freezers, i.e. assembled and hardwired. *Self-contained "Dluqin" coolers or freezers (appliance type) shall not require a mechanical permit. 5 9 o EF-13 E1---T1 11-71 E� DINING 1 104 (E) F&gTOR. (E E EF --I] 1E T-7-1 EF-D 8103 Q D 11 D 11Uj 11 D UL - All A3.1 TYP. > f II (E) COMMON EXIT CORRIDOR Fl-00-1 \1�1 114"=I'-C` XREF(5):1501-13 BASE File: 1601-13 A2.1 Floor Plandwe Date/Tlme: January 11, 2019 5:00 PM Scale: 1-45 Xrets: NEW HAND SINK - SEE KEC DWSS. FOR EXACT LOCATION A SPECS— (E) BACK -OF -HOUSE F-1-0-1 -1 e"�'.J3 EXIST'G. WALLS TO REMAIN 7r- EXIT CORRIDOR 116 (E) MEN 1-1-4 ENSURE THAT WATERPROOF MEMBRANE IS INTACT - PERFORM TESTING TO CONFIRM IN EXISTING KITCHEN 0RJ~V0UWA%VAW,KXISTING TILE TO REMAIN. NOTE: VERIFY ALL DIMENSIONS W/ DESIGNER 4, REFER TO DR4WINGS FOR ADDITIONAL DIMENSIONS IMENSIONS FOR F.F. 4 E. IT-W - VERIFY �4' - VIP. PROVII E 2' AIR SPACE 5ETWN. WALL 4 COOLER 10 BEER COOLER - - ------ ----------- --- ---------- --------------- ---------- -- ------- i FOOD PREP. i: L h J 7 - -------- --o BAR KITCHEN EQUIP. DWGS. FOR LICA =iE1;T1U11. 1 SPECS. IT - - i i - - _- � i __ Il)—� J: U LJ Zl= ER(4 1/2'7J 16'-11/4' E) DINING 1 107 177Ni— ----- 24'-2- - VEIFY rl r7 1'-1 1/2' /T 3 -1 1/2. 3'-IO'TIOT2211-101/2, A NOTE: REFER SHT412 L FOR iZ. PATH OF TRAVEL --J 7 ALCOVE 2 I(A' :T'OVIDE SHOP DU45. FABRICATION FOR DESIGNER/ J, C REVIEW PRIOR TO FA15RICATION 115 A E 8 [EA I A3.1 > FEMA ------- WOMEN -------- F1151 -------- 4 x �— EK", 4'-O' E � 9 1 lg - 3 ------- I SERVER STN. -------- DINING -111 ------- 1 110 DINING STORAGE Fl-06-1 NOTE: COOLER WILL BE SUPPLIED LYW'D. SURFACE. SEE KEC 4 DESIGN D1149. REFER TO KITCHEN EQUIP. b our.$, FOR SERVER EQUIP, B > 12 FU T. I / \ -M' I I I II I .1 &%II1Z1e11T,I 4040?k All concepts, designs, arrange,mente, and data Indicated on these documents are the property 0 developed for use on, and in connection with the specified project. None of such Idea., any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Ar.`it='El r SUBMIT PATIO FURNITURE AND PATIO FENCING FOR LANDLORD APPROVAL F— ENTRY 108 HOSTESS $TN. FZ1 I REFER TO m-F Dux S. FOR INTERIOR ELEVATIONS, SCRE EN WALL DETAILS, —FINISHES, ETC. --\ COUNTER DINING F-1-097 2019 o3 a. A. Miller Architecture and were created, evolved, and arrangements, or data shall be used by, or disclosed to J 8'A N11 LlnA A Fit.-rll I 7f V, tr 7f U Fi n J JJ J J J -J -J J -1 J -1 J 141 DEL PRADO LAKE OSWEGO, OREGON 97036 503.636.7979 603.636.9898 - FAX glonagamillerorchitec.tvre,coin CONSULTANTS_ MATHEWS CONSULTING GENERAL CONTRACTOR. EM PRECISION PUYALLUP, WASHINGTON V'714,REGISTERED ARCHiT T ARCHi� A. ER TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON OWNER, TRAPPERS SUSHI CO. SUSHIC2 COMMENTS - ADDEND. -VIEW MARK DATE DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 A2-1 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 @ copgIght 2018 GA MILLER ARCHITECTURE SHEET TITLE 0 APPROVED FEB 28 2019 City of Tukwila ISHEET or- I 6 m EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DU.GSJSCHEDULES EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUrSSJSCHEDULES NO CEILING ABOVE WALK N COOLER - Y F3] SEE KEC DWGS. JTi33I _1 rp3w". EXISTING CEILING/ (ETR)® LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DWGSJSCHEDULES O XISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DWGSJSCHEDULES N I'm EXIST'G. CEILING TO REMAIN THIS AREA, VERIFY NEW FINISHES - - W/ MF DIGS. (REMOVE EXIST'G. LIGHT FIX- TURES, INSTALL NEW FIXTURES AS SHOWN 4 SCHEDULED) E ,' _ — L T-O' AFF. BULKHEAD O �9 NEW 6' 20 GA. CEa FRAMING - I •O.G. 516' GYP. 15CE IL EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MP DWGSJSCHEDULES IV `_-- W _D (ETc / 0 - - �� j 'Wx ( I W/"mil I { - - CRILING PLAN XREF(5):1801-13 BASE File: 1601-13 422 Reflected Ceiling Plan.dwg Date/Time: January 10, 20le 5:2S Phi Scale: I=46 Xrefs: IN �!J C 0EXPO5ED TO STRUCTURE — SEATING/EQUIP. SHOWN BELOW T imTl��. i �fl off -H J REFLECTED CEIL'G. PLAN NOTES: ARRANGE EMERGENCY LIGHT FIXTURES TO. PROVIDE: INITIAL ILL- UMINATION THAT IS AT LEAST AN AVERAGE OF ONE FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. NIGHT LIGHTS. SHOWN SHALL BE DESIGNATED AS EMERGENCY LIGHT FIXTURES, ADD ADDITIONAL EMERGENCY LIGHT FIXTURES IF NEC- ESSARY (VERIFY IN FIELD). EMERGENCY FIXTURES SHALL BE EQUIP- PED WITH AN EMERGENCY POWER SYSTEM THAT PROVIDES POWER. FOR A MIN. OF - MINUTES, CONSISTING OF BATTERIES, UNIT EQUIP- MENT, OR AN ON SITE GENERATOR PER STATE CODES AND IBC SEC, 1006 2. CONTRACTOR TO LOCATE HVAC DIFFUSERS, RETURNS, 4 SPRINKLER HEADS TO SATISFY BUILDING, MECHANICAL, FIRE CODES, AND ANY OTHER APPLICABLE CODE(S). REFER TO LIGHTING 4 HVAC PLANS. 3. VERIFY ALL SPEAKER LOCATIONS 4 QUANTITIES W/ TENANT. CO- ORDINATE W/ LIGHTING, HVAC, AND EXIT SIGN LOCATIONS. 4. VERIFY ALL SECURITY CAMERA LOCATIONS 4 LOW VOLTAGE EQUIPMENT W/ TENANT. REFER TO M-F DRAWINGS FOR CEILING FINISHES, PAINT FINISHES, ETC. 5. THE TENANT SPACE IS EQUIPPED WITH FIRE SPRINKLERS. VERIFY IN FIELD ALL EXISTING LOCATIONS, AND RELOCATE / ADD ADD- ITIONAL HEADS AS NEEDED TO COMPLY WITH ALL APPLICABLE STATE AND NATIONAL CODES (DESIGN BUILD) 6. ALL CEILINGS ABOVE FOOD PREPARATION AREAS AND BACK - OF -HOUSE AREAS SHALL BE 2'x4' WHITE VINYL FACED LAY -IN TILES. MFR.: ARMSTONG OR APPROVED. COMPLY WITH ALL LOCAL HEATH DEPT. REQUIREMENTS LEGEND NOTES: INSTALL NEW CEILING 4 GRID - FORMER HOOD LOCATION. MFRJ STYLE/COLOR TO MATCH EXISTING GRID AND TILES NEW Tx4' TROFFER FIXTURE TO MATCH EXISTING �. EXISTING 2'x4' TROFFER FIXTURE TO REMAIN U.ON. EXISTING SUSPENDED CEILING GRID 4 TILE TO REMAIN U.ON. - CLEAN GRID AND TILES TO LIKE NEW CONDITION AS NEEDED. LANDLORD NOTES: A 1. CUT SHEETS OF ALL LIGHTING FIXTURES IN FRONT OF HOUSE MUST BE SUBMITTED TO LANDLORD FOR APPROVAL. 2. IF USED ANY PEOPLE COUNTER SYSTEMS MUST BE CONCEALED FROM VIEW AT STOREFRONT. 3. ALL EMERGENCY AND EXIT LIGHTING IN FRONT OF HOUSE MUST BE EDGE LIT AND HAVE RECESSED BASE - NO SURFACE MOUNTED. 4. ALL SPRINKLER HEADS IN SALES AREA MUST BE RECESSED AND THE COVERS PAINTED TO MATCH THE SURROUNDING AREA. IN OPEN CEILINGS, SPRINKLER HEADS TO BE RAISED ENOUGH THAT THE HEADS ARE ABOVE THE GLAZING LINE AND IN LINE WITH THE LIGHTING. 5. NO FREESTANDING CAMERAS WILL BE ALLOWED IN THE SALES AREA - MUST BE RECESSED INTO WALL, ETC. 6. VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN HANGING/SUPPORTING HVAC EQUIPMENT, DUCTWORK, PIPING, WATER HEATERS, TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANT'S ARCHITECT, ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. 10'-0' 1 11, 1 "-O' a' 3 rn— it 6'-O' RECEIVED 1 _ __. _. p CITY OF TUKWILA _ �[- 0 AN 17 2019 PERMIT CENTER EXISTING MERCANTILE TENANT SPACE zop All concepts, designs, arrangements, and data indicated on these documents arethe property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm,or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. � AM,r "A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7079 503.636.9898 - FAX g lena game I Ierarchltecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR- EM PRECISION PUYALLUP, WASHINGTON 6714REGISTERED (AR}CHIT T L N A. MIIIER STATE OF WPSNikGTOR TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER, TRAPPER'S SUSHI CO. 6i ii m 1-I1-IS ILL, COMMENTS - ADDEN. " 1 12-14-18 L.L. REVIEW MARK DATE. DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 A2-2 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 0 copyright 2018 GA MILLER ARCHITECTURE SHEET TITLE LTEDc CODE COMPLIANCE APPROVED FEB 2 8 2019 City of Tukwila 'G. PLAN SHEET OF File: 1801-13 A23 Door Schedule - Light Fixture Scheddwg Date/Time: January 14, 2015 11:38 AM Scale: 1.48 XreFs: -TEMPERED GLASS GOBS STYLES SEE SPECS. METAL THRESHOLD SET IN MASTIC BED - ADA COMPLIANT, MFR: PEMKO _...._,..._..__OR APPROVED EXISTING CONC. SLAB U _ TO REMAIN a a � � Q I0R DOOR SILL A23 3" ", XREF(S):--- D O O R S C H E D U L E(DOORNO=ROOMNO) DOOR FRAME NO. SIZE MATERIAL TYPE MAT. RATING HDWR. DETAIL REMARKS 103 V-O' x 1'-0' x 1 3/4' EXIST'G. FLUSH EXIST'G. EXIST'G. 108 V_O' x 8'-O' (VERIFY) GLASS B VA23 NOTE 4 106 3'-0' x 1'-0' x 1 3/4' EXIST'C, FLUSH EXIST'G. EXIST'G. NOTE "3 108 (E) PR V-O' x 8'-O' GLASS A EXIST'G. NOTES 14 3 114 3'-O' x 1'-O' x 1 3/4' EXIST'G. FLUSH EXIST'G. EXIST'G. 115 V-O' x 1'-0' x 1 3/4' EXIST'G, FLUSH EXIST'G. EXIST'G. Ilb V-O' x 1'-0' x 1 3/4' EXIST'G. C EXIST'G, EXIST'G. DOORA2RAME SCHEDULE NMS: 1, DOOR TO HAVE A SIGN THAT READS 'DOOR TO REMAIN UNLOCKED UNEN BUILDING IS OCCUPIED% 2. NOT USED 3. EXISTING HARDWARE TO REMAIN, VERIFY WITH OWNER ANY ADDITIONAL HARDWARE OR LOCKSETS/KEYS ARE REQUIRED OR IF NEW HARDWARE ARE REQ'D. 4. MATCH EXISTING DOORS STYLE, RAILS, HEIGHT, CLOSER, HARDWARE, FINISH. TEMP. GLASS. 1(2 /\ U-VALUE EXISTING H.M. DOOR WITH PANIC = 0b0 DEVICE 4 CLOSER (TO REMAIN) A B C GLASS 7 (EXISTING ENTRY) A3.2 DOOR LIGHTING FIXTURE (LUMINAIRE) SCHEDULE TYPE STYLE MFR. / CATALOG NO. NO. LAMPS / TYPE WATTS VOLTS MOUNTING NOTES A EMERGENCY/EXT LITHONIA ELM-6 LED 4.3 LED 4.3 120/277 WALL OR SUSPENDED EMERGENCY/ EXIT COMBO. BLACK FINISH SUSPEND CEIL'G. MTD. UNITS FROM STRUC. B EXIT LITHONIA LQHM LED B R HO RO 4.3 LED 4.3 120/277 SURFACE EXIT SIGN C 18" LED HIGH BAY MAX LITE LIGHTING T.B.D. 27 LED 27 100-277 HANGING RING MT. STUSSER ELECTRIC, ALEX - 206-623-1501 D 2'x4' TROFFER MATCH EXISTING (3) 32 W 96 120/277 RECESSED ACRYLIC LENS E FLUSH MT. CEILING LAVARDIN 1-LIGHT SEE NOTE # 4 BELOW LED - 3000K COMPATABLE 13 120 SEMI -FLUSH MT. P CUSTOM PENDANT I I LED - 3000K 118 1 120 1 SURFACE AQUA INSULATOR SHADE R 6" RECESSED CAN HALO PD6V120 HOUSING 16 LED - 3000K 18 120 RECESSED I MINKA LAVERY GT100-F-6" EFFETRA GLASS TRIM LUMINAIRE SCHEDULE NOTES: I, VERIFY ALL MANUFACTURERS, STYLES, COLORS, SPECS. ETC. WITH OWNER 2. VERIFY ALL SWITCH LOCATIONS WITH OWNER 3. VERIFY ANY AND ALL NIGHT LIGHT LOCATIONS WITH OWNER 4. www.wayfair.cam/browes-by-brand/pdp/Iavardin-l-light=outdoor-semi-Flush-mount-Irfy6384htmlvpnd=LED-3000k RECEIVED CITY OF TUKWILA JAN 17 2019 PERMIT CENTER U Do All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such Ideas, dealers, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation For any purpose whatsoever without permission of G. A. Miller Architecture. "., M J, �� 1A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.638.7979 503.636.9898 - FAX g lena gaml I I erorchttecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER' TRAPPER'S SUSHI CO. �PNP00, IN . (r BUSH) CO I I 1-1I.19 ADDEN. " I 12-i4-I8 LL. REVIEW MARK DATE I DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 A2.3 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 ® copyright 2018 GA MILLER ARCHITECTURE SHEET TITLE 6� CE�� FEB 282019 DULE I SCHEDULE WILDING DIVISION 33 e SHEET OF COOLER INTERIOR BAR / DINING 5/a' PLYWOOD FACTORY APPLIED TO COOLER INSTALL 5/8' GYP. BD. TO PLYWOOD, SEE MF DWSS. FOR FINISH, TYP. 1.1 OOL WALL 'tiON 11/74-0" XFZEf<ST-- FACTORY APPLIED PLYWOOD COOLER WALL 5/8' GYP. BD. - SEE MF DWGS. FOR FINISHES NEW STUD WALL - SEE. FLR PLAN 1® 000LIMIR LUF4L1. SrECOrION A3.1 N.T.S. XREF(S)-.-- <__ SEE A3 1 FOR ATTACHMENT TO T— STRUCTURE ABOVE ' MTL. STUDS ® 16' O.C. TO ;TURF W/ 5/8' GYP. BD. IC SIDE COOLER BOX FACTORY APPLIED 5/8' PLYW'D. 5/8' GYP. BD. - SEE Mr Duns. FOR FINISHES 11 00LNR WALL SNOTION A3.1 N.T.S. XREF(S):-_- A VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN HANGING/SUPPORTING HVAC EQUIPMENT, DUCTWORK, PIPING, WATER HEATERS, TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANTS ARCHITECT. ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. X 48 1220 o g Z Z ¢8 'EL411 4S cew : '° 1220 izzo � (ai rota: F ahaA ba 5 25" (475 mm) z MU to >., High Forward Reach Limit worn a <:20'• (5mmm) ,vv awo 60 +e^.(it2o mm} maara,. wbm a b 20^-2V (510 WOW mm), th. Y'09. ba 4a" (n20 =aa) m�xmam. (b)Fig. 5 Maximum Foward Reach aver An Obstruction Forward Reach- ACCESSIBILTY NOTE: ALL EQUIPMENT TO BE USED BY CUSTOMIERS SHALL HAVE NO OPERABLE PART GREATER THAN 40 INCHES ABOVE FINISHED FLOOR. XREFCS):-- UNI -STRUT ANCHORED TO TOP OF (E) ROOF TRUSSES / FRAMING (OR FLOOR ABOVE) ® 24' O.C. - REFER TO LANDLORD PROVIDED CONST. MANUAL FOR SPECIFICATIONS 45' S/V GYP. BD. ON 25 ga. STUDS o 16' O.C. CONCEALED WIRINS— J-BOX FOR PENDANT FI: 6' 20 GA. MTL. STUDS o 16' O.C. CEILING FRAMING � �1 5/W GYP. WALL BOARD CEILING -/ CONTINUOUS 20ga METAL TRACK ANCHORED TO (E) DECK W12-15 TEK SCREWS O 24'O.C. MAX. MTL. STUD KICKERS a 24' O.C: ATTATCH TO STRUCTURE OR UNISTRUTS 4 BULKHEAD W/ (3) - 8 TEK SCREWS, TYP. 10'-0' a LIQUOR BAR I CIE --SEE MF DWSS. IA I� n Ii Ii i� f 1 PENDANT FIXTURE - SEE R.C.P. 0 LIGHTING SCHEDULE �__-_----_- PiT 'CLOUD, I ",=,O.. XREF(S),-- ASTM A 36 112' THICK MIN. STL. BASE E:, SEE SPECS. REFER TO DESIGN DWSS. FOR PARTITION HT. STRUCTURAL GRADE 50 TYPE H 12ga STUD 9 46' O.C. MAX., SEE SPECS. INSTALL FRAMING ON EA. SIDE ANCHORS: L241 HILTI KWIK 1501-T-3 (31,2' MIN. EMBEDMENT INTO UN - CRACKED CONCRETE SLAB) NOTE: REFER TO SPEC. SECTION 05 50 00 VERFIY WALL HEIGHT WITH DESIGN DRAWINGS LIOUOR BAR ATTACHEp NC TO GFR ATTACHED WALL HANGER UNI-STRUT ANCHORED TO TOP OF (E) ROOF TRUSSES / FRAMING tOR FLOOR ABOVEI m 24' REFER TO LANDLORD PECIFICATIONS )NTINUOUS 20ga METAL TRACK CHORED TO (E) DECK W1 2-"S TEK REWS s 24'0.C. MAX 'L. STUD KICKERS a 24' O.C. 'TATCH TO STRUCTURE 2 UNISTRUTS 4 BULKHEAD (3) " 8 TEK SCREWS, TYP. 41NT TO MATCH ADJACENT CONST- ,ICTION COLOR 5/8'25 ga. METAL STUDS a ' O.C. MAX. PROVIDE )UND INSUL, as REST- DOM WALLS CIF NEW) -TI 'X-C' MX POWER -DRIVEN STENERS ® IS' O.C. (4' MIN.) W/ V EMBEDMENT .R ICC-ES CRITERIA, TYP. )LD GWB 3/6'-1/2' ABOVE CONC )NC. 6.01G. T%r. PARTITION eiraCTION A3.1 3"=,, XREF(S):-- XREfCSY•-- WHERE OCCURS, MOUNT THERMOSTAT -DIRECTLY BESIDE LIGHT SWITCH SU& QS OT-S. LOCK/LATCHCH SET !. C DUPLEX RECEPTACLES, PHONE ' LEVERS FOR EXIT DEVICES, LATCH - AND DATA RECEPTACLES SHALL .SETS, AND LOCKSETS SHALL BE CENTERED BE MOUNTED WITH BOTTOM OF THE AT SAME DIMENSION ABOVE THE FINISHED OUTLET o I'-3' AFF. UNLESS OTHERWISE FLOOR U.ON. NOTED. 4 U TILrE BAN 0 WALK- IN 2 T MOUNTING* iC* 6 A3.1 N.T.S. XREF(SI:"' A3.1 =1'-O" XF?EF(S):-_ UNATTACHED WALL HANGER WIRE W/ STRUT AND SPLAY WIRES PER CEILING BRACING DETAIL �eevemememmeRe®®®®®4 ra Re --- FREE END FIXED END 1/W ANGLE MOLOIN --2' ANGLE MOLDING POP -RIVET- UNATTACHED THIS SIDE SEISMIC SEPARATION JOINT FOR CEILINGS OVER 2SOO SF. (IF APPLICABLE) JA3.1EI_'�PQNY WALL AMiN5Y.4_1" XRERW, A3.1 Flts: 1,301-13 AW Interior Elevations and Detafls.dwg Date/Time: January 10, 2015 5:30 PM Scale: 1=46 Xrefs: RECEIVED CITY OF TUKWILA JAN 17 2019 PERMIT CENTER +�— MAW IZUNNER �I V� FROM EA. NOT OTHER EXCEED CROSS RUNNER ANGLE NOT EI INGEED NE. FROM THE CEILING PLANE. LATERAL SWAY BRACING FOR CEILINGS OVER 1.000 SF. FLOOR. AND/OR ROOF STRICTURE ABOVE ARh1STRONG BER02 CLIP (AS ALTERJATE MEANS OF CONSTRICTION IF APPROVED BY SLOG. OFFICIAL) ADDITIONAL HANGERS AT ALL MAINS WITHIN W OF THE PERIMETER 1/2' EMT UP TO V-10' 4 3/4' EMT UP TO T-8' STRUT e 12'-0' O.C. EA. WAY WITH 4 WAY LATERAL BRACING FROM THE MAIN RUNNER TO THE STRICTURE OVER BEGIN WITHIN W-O' Or THE PERIMETER AND 71' FROM A CROSS MEMBER ��tAX �'- SECURE ALL HANGERS TO BLDG. STRICTURE OR A TRAPEZE FOR DUCT 6' C, MAX AND/OR PIPE. WORK CROSS MEMBERS BETWEEN. MAIN RUNNERS MAIN RUNNERS AT 4'-0' O.C. SUPPORT WITH e12 WIRE AT 4'-0' O.C. OR WITH -10 WRE AT. 5'-O' O.C. COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB NOTES: 1. ALL CONNECTION DEVICES TO BE IBC 2012 4 ASOE-1-10 APPROVED TYPE AND HAVE 100 LB. CAPACITY XREF(S),'--- All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architsct-7T-and TerelthreatW, evolved, and developed for use on, and in connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. jrAMA 8A N1 0 EIA J J J J J J J J J J J J _I 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX g lenagomi I lerarchltecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR, EM PRECISION PUYALLUP, WASHINGTON 6714 RETERED �AAR�CjIgTT CETE TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER, TRAPPER'S SUSHI CO. N/P PA 0, i 1-11-IS LL. COMMENTS -ADDER " 1 I2-14-IS L1. REVIEW i MAPVI DATE DESCRIPTION JOB NO.: 1807-13 FILE: 1810-14 A3-1 BY: PLAN CHECK NO. PERMIT NO, DATE: DECEMBER 14, 2018 copgrlght 2015 GA MILLER ARCHITECTURE S Z T-E-----' -.-'-- I RI-EVATIONS .• CAI FEB 2 8 2919 City of Tukwila BUILDING DIVISION S e SHEET OF REVISIONS rer�r.>.►>,�rv»aivui�������>..rcrvz.ri� MAX. EXHAUST PLENUM TOTAL HOOD CONFIG. TOTAL RISERS) HOOD TAG MODEL LENGTH COOKING SUPPLY HOOD END TO WIDTH LONG. HEIGHT DIA. CFM VEL. S.P. NO TEMP. EXH, CFM CFM CONSTRUCTION END ROW 5424 600 430 SS 1 ND-2-PSP-F 13' 6" Deg 3172 4" 18" 3172 1795 -L 046' 2854 Where Exposed ALONE ALONE PATENT NUMBERS AC-PSP (United States) - US Patent 7963830 B2 AC-PSP Wall (Canada) - CA Patent 2820509 AC-PSP Island (Canada) - CA Patent 2520330 FILTERS) LIGHTS) UTILITY CABINET(S) I HOOD TAG _ EFFICIENCY 2 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES FIRE SYSTEM HOOD ANGING TYPE SIZE MODEL # QUANTITY NO. TYPE QTY. HEIGHT LENGTH �y'TYPE LOCATION SIZEMICRONSGUARD PIPING WGHT I Captrate Solo Filter 10 20° 16" 85% See Filter 12" x 12" LED NO Left 12'x54"x24" Ansul R102 3.0/3.0 DCV-1111 1 Light YES 917 Spec, 1 Fan LBS HOOD NO. TAG. OPTION _ RIGHT QUARTER END PANEL 23' Too Width, 0" Bottom Width, 23' High 430 SS INSULATION FOR BACK OF HOOD I LEFT VERTICAL END PANEL 27' Top Width, 21' Bottom Width, 80' High Insulated 430 SS SENSOR -CV DMEIL DeA— —T—Tv nr Lnrrr a,rlaI HOOD NO. TAG POS. LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG, DIA. CFM S.P 1 Front 174" 18" 6" MUA 12, 28' 713 0.192" MUA 12' 28' 713 0.192' MUA 12' 28' 713 0.192' MUA 12" 28' 713 0.192" I' LAYER OF INSULATION FACTORY NSTALLED IN INTERNAL BACK STANDOFF, MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3' T— LajO j 018, I U.L. Listed 12' x 12" Recessed LED Light Dd 54 UtRity Cabine 28' 28' 28, p rol __� 12'— _ —._.— ---_—_—_ _—_---_--� 12'—iK'� 12'—EM 9. 18' al' 81' 21 3 4' --�� 43 1/2' -) 43 t/2' - 43 1/2' -- 12 -- 13' 6'Non./13' 6.00'DD 14-6.00' Overall Length PLAN VIEW - Hood $1 13' 6.00i1 LONG 5424ND-2-PSP-F NOTE: Additional hanging angles provided for hoods 12' and longer. HOOD CORNER 1/2' - 13 TPI HANGING ANGLE T/2' - l3 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS (HARDWARE BY INSTALLER) DE s (MINIMUM) STEEL HENUTS 1/2' GRADE 5 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER INIMUM) STEEL — FLAT WASHER 1/2' - 13 TPI GRADE 5 NDFHUNN) STEEL -THREAD 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL ALL -THREAD ALL 1/2' - 13 TAT GRADE 5 (MINIMUM) STEEL HEX NUT 1/2' - 13 TAT GRADE 5 (MINIMUM) STEEL HEX NUT 1/2' GRADE 5 NEED CGRNER INIMUM) STEEL FLAT WASHER HANGING ANGLE WEIGHT BEARING 1/2' GRADE 5 (MINIMUM) STEEL ANCHOR PRINT FOR HCDA, FLAT WASHER 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER 1/1 - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS FULL LENGTH HANGING ANGLE (HARDWARE BY INSTALLER) SUPPLY PLENUM GRADE 5 THIN MUM) STEEL HEX NUTS HANGING ANGL (HARDWARE BY INSTALLER) 1/2' GRADE 5 (HINT MU D STEEL FLAT WASHER 1/2, - 13 TPI GRADE5 (MINIMUM) STEEL ALL -THREAD 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT SUPPLY PLENUM GRADE 5 (MINIMUM) STEEL HANGING ANGLE H"IGHT BEARING CHAR PG[NT FLAT WASHER PER SUPPLY PLENUM) 1/2' GRAD E 5 (RUN1MUM) STEEL FLAT WASHER Le' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWII CH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WTH 1/2' GRADE 5 ANGLES AND CEILING ANCHOR POINTS WTH 1/2' GRADE 5 ANGLES AND CEILING ANCHOR POINTS WTH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE GRADE 5 (MINIMUM) HEX .NUTS AS SHOWN, MUST USE GRADE 5(MINIMUM) HEX NUTS AS SHOWN, MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING DOUBLED HEX NUT CONFIGURATION ABOVE CEILING DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANGLES AND ABOVE CEILING ANCHORS, MAINTAIN 1/4, OF ANCHORS, SINGLE HEX NUT BENEATH HANGING ANGLE IS ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE ACCEPTABLE FOR FULL LENGTH HANGING ANGLES, ACCEPTABLE FOR PSP HANGING ANGLES, MAINTAIN 1/4' OF ALL HEX NUTS TO 57 FT-LBS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS. ALL HEX NUTS TO 57 FT-LBS, EXHAUST RISER HANGING ANGLE 20' CAPTRATE SOLO FILTER WITH HOOK 1° LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP RIGHT QUARTER END PANEL GAS CHASE CUTOUT (FOR GAS AND POWER LINES) LEFT VERTICAL END PANEL WITH ADJUSTABLE LEGS SPECIFICATIONi CAPTRATE' GREASE -STOP' SOL❑FILTER THE CAPTRATE GREASE -STOP SOLD FILTER IS ASINGLE-STAGE FILTER FEATURING A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR.BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2-INCH DEEP HOOD CHANNEL(S), UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED, GREASE EXTRACTION EFFICIENCY PERFORMANCESHALL LL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED LOINCHES OF WATER GAUGE, THE CAPTRATE GREASE -STOP SOLD WAS TESTED TO ASTM STANDARD ASTM F2519-05, EFFICIENCY VS. PARTICLE EXULMI UER PRESSURE DROP VS. FLOW RATE z m PARTICLE. IF DIAvIETER(U.) 1. CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96 NSF STANDARD #2 UL STANDARD 4 1046 INT. MECH. CODE (IMC) OLD -S649 SECTION VIEW - MODEL 5424ND-2-PSP-F FLOW RATE (cfrn) LED LIGHT, 3K WARM FTACHING PLATES UPPLY RISER WITH 'OLUME DAMPER 235% OPEN STAINLESS STEEL PERFORATED PANEL CODE COMPLIANCE APPROVED FEB 2 8 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 17 2019 PERMIT CENTER d CV Qj :2:00 S 00 41 : ED O 4Ql C� I � Q Un sUn 3 5 4I 5 W O _J Q 00 Q `D LIJ DATE:1/14/2019 DWG.#: 3679252 DRABy. RTB - 85 SCALE: 3/4" = 1'-()" MASTER DRAWING i REVISIONS NMI 4 Hood Back 7 T _ — , GO � 3z:ov m� 24.00' IMSM, 24.oa' o.od' Is ... L — — — — _—---�-- — __I II r1 II II r, II II r., II Hod tt t Job W 3595328 ® Models ND-2-PIP-F Sizes 54'x24' Length 13' 6_ IJ am A E /EL '''//�/,,,�.I LINE DAMPER P A EHNNGINa ANGLE l ' C STEttEL GPERFDRA �E➢EP. SECTION PVJ.$W-MODEL 5424ND-2-PIP-F HOOD - 41 21rCT NOZZLE AND PLENUM SPRAY BAR LOCATION Job If 3679252 Job Names Trapper Sushi - South —ter Mall RI System Sizes ANSUL-3.0/3.0-MANIFOLD Total FP required 15 Hood # 1 13' 6,00' Long x 54' Wide x 24" High Riser # 1 Size, 0' x ; NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE, IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF. 6" ABOVE THE TOP OF THE HOOD - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. THIS FIRE SYSTEM COMPLIES WITH UAL, 300 REQUIREMENTS Job #: 3595328 Job Names Trapper Swhi - Federal Wny RI Drawn Byy: System Si- � ANSUL-3A/3.0-MANIFOLD Total FP required) 15 Hood it I 13' 6,00' Long x 54' Wide x 24" High Riser N 1 Size, 18' Dla. Hood # I Metal Blow -Off Caps included. LEGEND - FIRE CABINET ANSUL l3rSTEM IA L5 GALLON TANK I 3 GALLON TANK 2 OEM AUTOMAN RELEASE 3 OEM REGULATED RELEASE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT ( L 5 GAL.) 7 CARTRIDGE 1111-211 8 CARTRIDGE (101-10) 9 CARTRIDGE (101_30) 9A CARTRIDGE (LT-A-101-30) 9B DOUBLE TANK CARTRIDGE SO TEST LINK 11 DOUBLE MICROSWITCH 12 HOSE ASSEMBLY 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) iW NOZZLE ASSEMBLY (419336) IF NOZZLE ASSEMBLY (419333) IN NOZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY C419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REMOTE MANUAL PULL STATION S SWIVEL ADAPTOR NOZZLE BY CER IFIED INSTALLERS ONLY IN THE LOCATID NOTED ABOVE, TWO SITE DUST PRIT11TID1 CHARGES), ONE MECHANICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE BE NOZZLEie2 , PERMIT, AND SYSTEM TEST.E CLLUIES� UNION LABOR R PREVAILING WAGE <LABDR & WAGES WILL BE DETECTOR A DER IF APPLICABLE>, GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CGNNECTIUNS, HANGING OF FIRE C BINET, SHUNT TRIP, MANDHELD EXTINGUISHER(A), GN-SITE RE -PIPING DUE To EQUIPMENT LAYOU—BES. REMOVABLE STAINLESS J STEEL SERVICE DOOR AGENT TANK OEM RELEASE/ BRACKET ASSEMBLY NOTES - FIELD PIPE DROPS AS SHOWN APPLIANCE PROTECTION SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS NOZZLE - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. p - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. ® 6 — OPTIONAL PRE -WIRE➢ ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS, - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE a -PHASE CONTACTORS AND OVERLOADS FAN AND LIGHT (IF APPLICABLE) SIZE, NOT THE OVERALL APPLIANCE SIZE, CONTROL PANEL - THIS FIRE SYSTEM COMPLIES WITH U.C. 300 REQUIREMENTS SPECIFICATIONS TYPICAL, ANSUL R-102 SYSTEM LAYOUT THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED TYPE WITH A FIXED NUZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC. (ULI TH SYSTEM SHALL BE CAPABLE OFAUTUMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES, IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIDUID AGENT HANDLING AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM, THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. FIRE SYSTEM Do Tag TYPE �— SIZE FLOW ppINTS INSTALLATION SYSTEM LOCATION ON NOOD i — A-1 Na. 3.0/aS N3 Hre Cabinet Left Left FIRE SYSTEM TAG TYPE SIZE SUPPLIED BY NO. _ t <al G. C,,,U eAire Systems KEY NUMBER - PART RESPRIPTION 0� ©0 ©� 00 00 �O —_� ©� ©� �0 0 o ®o i©o 0 IDIU �o ..... . 36 - 36 - PE -HT PULLEY ELBOW HIgh I— P.ttPy CIE.., C.Npres_r Type, A-1 Part ®= REVILVVED FCR CODE CO.MPLIANCE APPROVED FEB 2 8 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 17 2019 PERMIT CENTER J s CO s s u 3 5 W O _J N � F- 0- Q R_ W __ Izzi- M DATE: 1/14/2019 DWG.#: 3679252 DRABy RTB - 85 SCALE: 1 /2" = V-0" MASTER DRAWING SHEET NO. 2 REVISIONS NO. TAG PACKAGE # LOCATION SWITCHES OPTION FANS CONTROLLED TYPE I 0 I H.P. VOLT 1 FLA LOCATION QUANTITY 1 DCV-1111 Utility C.lUCCt Left M - Utp-t-Y-7DEI-t laft I Light 1 Fan Smart Controls DCV Exhaust 3 2,000 208 of HU.CI It 1 SCPPIy 1 3 2C001 208 6A ..... ..... t . . ..... CASUnk Monitor and Control - N F,Ft,,t AUHPk t, PUMP- commun cations t. cloud based B.lLdiFg VQ — System Hood C.FuW P-P1 t.- allow cloud based Building Management System t, Nt., realtimeAP,am,tea--d AS MONITOR in the P.1- ti't. 1- Control Fv1F1 IT, FIWU F-O-O-Ol BNPR1,m S,t- t. FFN"UA P .... PtP x outlined s CONTROL " the points UPIA - HN F.Ftr.1 P-1 to R.,, remote FC- I. system PvtUTF, such III IrA,O-AIP" ECM OPUPP., t-p-t-A P.t P.-A, - and P-1, ( AMONITORING AND CONTROL POINTS LIST - JOB NO ODEL NUNBER DCV-1111 D U�CUl �T ID N ,0 OPERATION 3679252 N, OB NAME IF— E.— I A-7,= Ft., BREAKER PANEL TO PRIMARY CONTROL PANEL CONTROL PANEL TO ACCESSORY ITEMS U. YOF - - - - - R.E -EIE111t, Usatrid- R-p-IbItity, El..trki.H "I -TAIT _NTR u. ED .,AXEA SIZEPSHOWN IS THE MAXIMUM ALLOWED COX, U-11__SUFMInt-, - ASL IREE, -COMPONENT. y IF. ,AT Illy .. 'PALUT - - - - _TPS PER ITAKE, E.RFPC_ PAXFL FATUP L WFtMTCTS LLLLM�iil HIJ AT-01 CAIEL U-TAN I ERM A IF. TO Om GNIWSUN 1AU .1 Da v CONTROL POWER. ED TO THMRIU PC —E -,a IS, DFC OR SHUNT TRIP v. 1:,TEWLR:%L�NOoA NX -WV OUTPUT CREAK a TO CA* TO ECMPS&,TMRTxU_U ED T P LIST mal Lam EXCAPPI Sustl 11 SUFTAPITTI ARP. CA PCC CUP Iffl- [1,� T�ASLAL PWNU_ HWAA. SAITEI .1 ,Cr_Z PRNI vFS AUALIC �-AV EUTPUT[� -7 E111IE1 IFIRE ENTNT U%C'E F_ T,:k,aXC`VF d TO EAS - - - - - - - RI SERIES Is suall L PrU 0F.M2 TTE"MAW IRIA I [ - - - - - "' SEE - P-IS -1. M " A - - _OgNE S .A IT A 'M_ XMI FWTTn 1ERVIE' IFTA SUICK URC-C L; .1 I-STES FASTERY ITIFIA CALI_ `T--NJ I TO A FAT-1 ADCCIP.� - - - - - - - - -- SUT F SWITC, P P—A PHT CITED VICL PUTYPTE ZDAU FAxS POD -- xrs ICAP - A SUP:i2 - - - C�2 PIRE. CASE - - -- - - - AS. LRITI I L tiaw, N A (WIRE TO IFI DICK UU11ECTM TO - - - TO ""TI -Tv I'. W na, TUD -POP aw-mow I - CONTROL PANEL TO FANS SENT-RM-PAUICL -S ETTEXPET -ECTITS isR-p-bift, Et,E1U,X,1PN TO PRIMARY PARDS. PA., WORLD ISE FA 11 �'ASNCSP 'T'1`APF`1(I't`Z1"" TORRIOL PANELEMACI TO _ST& I.E. TERPF= IM' TC`P 21 11IRPP"�NwQO TS MAT MCTUR MUST IIVE ITS am 1111SIL-P T NIZA.PT."OPSIR TO PDT SinS, COMPUTO - US a, IA DLUPE AUD .1 PARUIU. TO P SPIPTURE WPLUP. SEII RI 11 A "'U" "A ", I. TO SUDSUP Aaw, IS " ETD &14� I CAPT JIL-NITS NOT AVSHARE TSCaEM UISTD,NITUT REOUTRE&US SECOTN AMITE TIM PAMIUL PAID L FRAT FDA ST TPAPTE UP NNPF11 CRAPPED [IL - - - - - - - - EWT PL ST TE1MPNA_ IS EITIMIED - - 1 1 FIREC111IT11 zz LOW -TA TAIPER I1T2FLCRK"1`1Tl?N FOR ZME"'AMPSYSIULLD" CNDPAU"NlRC= - - - - - - - - MWE MITIMIT 11ARE 1111 Qa,,�, SPAS _.AFFMALLY .1Ea IS PROVEN FFE,� WAPI IMPER SYSTUP Isy A LLM`P` 'A _23 NOT REW CA ALL CA CART.T FRE A Ex TATTERWIS NAL CIO SEE MAKE 1�,�,DF, AUSE USS. TO UPPAUS —.1 R IDICIMIS 'AIMIT IF U"D "RE"Ly - — 11ITIAMIC IIIIAH NOTAM 11 TA MATUT, P.- A B I C I OIL- SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWO ALL FACTORY DC WIRING IS APAG. I F I G I H MOTOR POWER CIRCUIT _' 'FACTORY WIRING' SCHEMATIC I 1ETC1 11 V11 HA I — TUta USE IT & LE ON-1 CIRCUIT S ig 120V CONTROL INPUT [of N_RRE PA EE, -NEUTRAL, I- T GAS BREAKER. DO K q) NO 'ECT I T CONNECT C I v 2 K T SHUNT TRIP D DREAC R "V 0 , 0 J� I 0 DO_, M "I sAn-a.) IF VFU HAS DAM COV WIT, LI T IP PAS . _'P, "T wa I ' VT C 4. IS j'K 'I L IF L I I URLY. ITRE-1 %A�1. 'Put- P1020.0 PE -a ECPMODAR DCV 91,13 FPII R., B'IDLOO - RELAY M ME "I SOL TIED PS -al INSTALLATION PlsO of PisrsDa (7)1 C IN ARMT. J 1KftxRFwCUE5vPO, P-P5 , A,, mE SU FLA IT PANEL ID IF T I .1 �P` 5 3 .,A. I PAT, Caa.... CHAIR PUPS :-;LE K -LS :IS PP110ro PPIP-zA I IONIAF 1DCPC_,FPpplva U- N. .......... J7 120V ZA DR 1 BE HT Otr_ ra , , " R FIPPCFaNt 5 MA L ons F-, P". 6 7 ..a UP SIT, 11 UT THO, IM11 M 'A IN DRY CONTACTS <SHOWN DE -ENERGIZED) 14 "1 RA-1-1 -L :ff3,o- T4 A.CA-I-I OUP N ECPnos EFLIILP __ OF w-E-S SUCOREACY PANEL X CAAP 0 1 SC-20 x 18 x EUDE It - Demand Control Ventilation Hood Control, Panel Specifications; - Controls shalt be listed by ETL (UL 508A) and shalt comply with demand ventilation system turndown requirements outlined in IECC 403.2.8 (2015). DUCT TEMPERATURE SENSOR - The control enclosure shalt loe MENA 1 rated and fisted for installation inside of the exhaust hood utility cabinet. The control enclosure may be constructed of stainless steel or painted steel, - Temperature probe(s) located in the exhaust duct riser(s) shalt be constructed of stainless steel, - A digital controller shalt be provided to activate the hood exhaust fans dynamically based on a fixed differential between the ambient and duct temperatures sensors. This function shalt meet the requirements of IMC 507.1.1. - A digital controller shalt provide adjustable hysteresis settings to prevent cycling of the fans after the cooking appliances have been turned off and/or the heat in the exhaust system is reduced, CONTROL PANEL - A digital controller shalt provide an adjustable minimum fan run-time setting to prevent fan LED cycling. INTERFACE ROOM 1EM111AI111 - Variable Frequency Drives <VFDs) shalt be provided for fans as required. The digital SENSOR contr otter shalt modulate the VFDs between a minimum setpoint and a maximum setpoint on demand, The duct temperature sensor nput<s) to the digital controller shalt be used to TYPICAL HOOD CONTROL PANEL INS7ALLATION calculate the speed reference signal, - The VFD speed range of operation shalt be from 0% to 100% for the system, with the actual minimum speed set as required to meet minimum ventilation requirements. Sequence of 11gerations; The hood control panel is capable of operating in one or more of the following states at any - An internal algorithm to the digital controller shalt modutate supply fan VFD speed given timeI proportional to all exhaust fans that are located in the same fan group as the supply fan. Automatic; The system operates based on the differential, between room temperature and the temperature at the hood cavity or exhaust duct coltar. Fans activate at 0, - The system shalt operate in PREP MODE during light cooking toad or COOL DOWN MODE when configurable temperature differential threshold, Depending on the job configuration each fan sufficient heat remains underneath the hood system after cooking operations have zone can be configured as static or dynamic. These terms refer to whether a variable completed. Operation during either of these periods wilt disable the supply fans and provide motor (such as EC Motors or VFD driven motors) moolutate with temperature. If the panel is an exhaust fan speed that is equal to the minimum ventilation requirement, equipped with variable speed fans and the zone is defined Its 'dynamic', these wilt modulate within a user -defined range based on the temperature differential, Panels equipped with - A digital controller shalt disable the supply fan(s), activate the exhaust fan(s), activate variable speed fans and a fan zone defined as 'static', fans will run at a set speed the appliance shunt trip, and disable an electric gas valve automatically when fire condition calculated for the drive. Demand control ventilation systems are capable of modulating is detected on a covered hood, exhaust and make up air fan speeds per the requirements outlined in IECC 403,2,8, - A digital controller shalt atlow for external BMS fan control via Dry Contact (external Manual; The system operates based on human input from an HMI, control shalt not override Fan operation logic as required by code). Schedule A weekly schedule can be set to run Pans for a specified period throughout the - An LCD interface shall be provided with the following features. clay, There are three occupied times per day to allow for the user to set up a time that is a. On/Off push button. fan & tight switch activation suitable to their needs. Any time that is within the defined occupied time, the system wilt run lo. Integrated gas valve reset For electronic gas valves <mo reset relay required) at modulation mode and follow the fan procedure algorithm based on temperature during this c, VFD Fault display with aucillote & visual alarm notification time, During unoccupied time, the system wilt have an extra offset to prevent unintended Cl. Duct temperature sensor failure detection with audible & visual alarm notification activation of the system during a time where the system is not being occupied, I. Mis-wired duct temperature sensor detection with audible & visual alarm notification f, A single tow voltage Cat-5 RJ45 wiring connection Otherl The system operates based on the input from an external source (DDC, BMS or g, An energy savings indicator that utilizes measured kWh from -the VFDs hard -wired interlock) c5 U � CIO co 4� :5 Q)L — CO 0 4 U 0 __J Q_ CD_ 00 c5 LD Ld ' _V' Ku _ki�IEv'EO FOR ' - '-' FOR 'R DATE: 1/14/2019 Co"" CODE LANCE CODE COMPIOLIANCE A APPROVED P 0 ED P Rj DWG.#, . LRE FEB 282 FEB 28 2019 01 3679252 DRAWN Ill - 85 City of Tukwila SUILDING DIVISION SCALE: RECEIVED 3/4" = 1'-0" CITY OF TUKWILA MASTER DRAWING JAN 17 2019 PERMIT CENTER SHEET NO. 3 REVISIONS System Design Verification (SDV) If ordered, CAS Service will perform a System Design Verification (SDV) once all equipment has had a complete start up per the Operation and installation Manual, Typically, the SDV will be performed after all inspections are complete, Any field related discrepancies that are discovered during the SDV will be brought to the attention of the general contractor and corresponding trades on site, These issues will be documented and forwarded to the appropriate sates office, IF CAS Service has to resolve a discrepancy that is a field issue, the general, contractor will be notified and bitted for the work, Shoutol a return trip be required due to any fletcl related discrepancy that cannot be resolved during the SDV, -there will be additional, trip charges. During the SDV, CAS Service will address any discrepancy that is the fault of the manufacturer. ShouLd a return trip be required, the general, contractor and appropriate sates office will be notified, There will be no additional charges for manufacturer discrepancies, CODE COIMPLIANCE APPROVED FEB 2 8 2019 City of BUILDIhlG DIVISION CITYOF EIVED CITY OF TUKWILA JAN 17 2019 PERMIT CENTER 41 41 5-- Qj � co U co 41 :3 0) CO 0 401 U U) 7) Lj 0 _j ch Q_ <: C5 �D LLJ -1- (4 DATE: 1/14/2019 DWG.#: 3679252 DRAWN By.RTB - 85 SC ALE: 3/4 = 1 1 _0" MASTER DRAWING SHEET NO. 4 ELECTRICAL LEGEND TWO WAY SWITCH $3 THREE WAY SWITCH $2P TWO POLE SWITCH $D SWITCH WITH DIMMER $OS SWITCH WITH OCCUPANCY SENSOR DUPLEX RECEPTACLE, +18" TO CENTER UON RECEPTACLE WITH USB CHARGING PORTS, +18" TO CENTER UON FOURPLEX RECEPTACLE, +18" TO CENTER UON GFI DUPLEX RECEPTACLE, +18" TO CENTER UON ISOLATED GROUNG ORANGE DUPLEX RECEPTACLE Q JUNCTION BOX JJ DOUBLE GANG JUNCTION BOX SPECIAL RECEPTACLE DIRECT CONNECTION AFF ABOVE FINISHED FLOOR SU STUB UP (OUT OF FLOOR) CM CEILING MOUNT RECEPTACLE IG ISOLATED GROUND 11h^ WATERPROOF CIF GROUND FAULT © TIME CLOCK 04 TELEPHONE/DATA - 1" C. TO BKBD Q CABLE OUTLET W/RG6 SHIELDED CABLE TO BKBD DISCONNECT SWITCH 4 MOTOR CONNECTION r11VV' FLEXIBLE CONNECTION TO EQUIPMENT — — CONDUIT RUN BELOW FLOOR OR CONCEALED IN WALL CONDUIT RUN CONCEALED IN CEILING OR IN WALL —�f}— NO. OF WIRES IN CONDUIT - (2) #12 & GRD MINIMUM BRANCH CIRCUIT HOME RUN BRANCH PANEL80ARD ® TRANSFORMER A INDICATES LIGHT FIXTURE TYPE. PENDANT LIGHT ® SPOT LIGHT -(�- COMPACT FLUORESCENT TRACK LIGHT ® EXIT LIGHT W/ EMERGENCY BATTERY PACK WALL SCONCE 24"x 48" LIGHT FIXTURE N.L. NIGHT LIGHT (ETR) EXISTING TO REMAIN LANDLORD/TENANT CONSTRUCTION NOTES IF CORING IS REQUIRED - PROVIDE CORING PLAN TO LL AND BASE BUILDING m STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL. TENANT GC TO SCAN SLAB PRIORM TO CORING T. 9 DINING 04 (E) 8 EIEC. /STOR. (E OFFICE EC. 03 EXISTING PANELS A', 'B' AND 'LP' El B-13 B-15,17 (E) COMMON EXIT CORRIDOR 00 A-2 (E) BA' ' RELOCATE EXISTING I MAKE-UP NEW HOOF RECONNEC ro C EXIT CORRIDOR 16 (E) ALCOVE 12 (E) MEN 114 f=0WEf` FLAN SCALE: 1/4" = V-0" a,_ A-i II A-37 A-18 Fr— _ — — — _ — — — _ J -I-I STORAGE 106 17 .I 16 B-12, B-i6 BEER COOLER A-35 15 L B- 8-20 ----- 116 5' Bps II B-22 I L'====-------------==='J C1� 110 Is^ 57 '4 u DINING 07 131 LP VIA TIME CLOCK GN qJ 92 i 30 i 29 I 83 _ ENTRY 108 H06TE65 STN. ❑7 A-39 57 , ------ ° 133° i-------7 — _ I 134 I I F24° 129-------7 C-2 0 C 1 i WOMEN MS° 130 I�� ^ 115 = I ------- COUNT' 7 ''^fit . -E-3 -: R L�-4' C-6-------i AP,IF F;aV I I I FE 28 9 j Z SERVER STN. H DINING offDINING Ci oI US BUILD NG ISION 132------- I T EC U D C OF KWILA C ¢200, 7 -------- ------- JAN 2019 RM ENTER 9 8 21 C-7 T. NNN EXISTING PANEL 'C' ® Pq�(�,o� All concepts, dealers, arrangements; and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, d developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements; or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A, Miller Architecture. 1 A J`i. .A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503, 636.7979 503.636.9898 - FAX g Ienagomi I lerarchitecture.aom CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON 674 REGISTERED /AjRCF(IT T E LER3 ER S. IL�_.��GLE TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. ASL ,��ww 1*c SUSHI C2 101/11/1-1 LANDLORD/ADDENDUMM ' 12/16/16 GORP/O7NNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: ® wpyrlght 2013 GA MILLER ARCHITECTURE SHEET TITLE POWER PLAN 10 1 SHEET OF (E) COMMON EXIT CORRIDOR 1= LIGHTING:; f=L,4 SCALE: 1/4" - V-0" 11-1-11 "Imma lo— All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, 45,00 developed for use on, and in connection with the specified project. None of S.ch or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. a ,� J\�jj , r JA 91A 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 — FAX glenagomillerarchil,ecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON .... REGISTERED' �IT T 'W GLE A IL STATE OF WigNINGTOR 4�9 TRAPPERS SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON OWNER: TRAPPERS SUSHI CO. A�NPP SUSHI Ca OVII/Iq LANPLORIWA00ENVURIM 12 �I,ORP/ONNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: 0 copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE COLkq-,IT C AMM"OVED FEB 2 8 2019 City of Tukwila P1,1111 PPIG PlUl."O" PLAN ISHEET OF ELECTRICAL NOTES: 1. RECEPTACLE MOUNTING HEIGHTS NOT INDICATED ON ELECTRICAL PLAN SHALL BE AS CALLED FOR ON THE ARCHITECTURAL DRAWINGS. ALL GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED AT 16" A.F.F. - 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE ALL MATERIALS, EQUIPMENT, AND LABOR AS SHOWN AND AS NECESSARY FOR COMPLETE WORKABLE SYSTEM. ALL MATERIALS AND EQUIPMENT SHALL BE NEW MATERIALS AND FREE FROM ANY DEFECTS. U.L. LISTED COMPONENTS REQUIRED, COMPLY WITH ALL GOVERNING CODES AND ORDINANCES. 3. TYPICAL SWITCH HEIGHT IS +48" A.F.F (U.O.N) 4. ALL TELEPHONE/DATA CABLE IS TO BE PLENUM RATED WIRE OR NON -RATED WIRE INSTALLED IN CONDUIT ABOVE CEILING OR IN WALLS. 5. CONTRACTOR TO SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS FEASIBLE AS SHOWN. VERIFY LOCATIONS OF ALL OUTLETS IN RELATION TO STRUCTURAL AND OTHER ELEMENTS AS REQUIRED. NOTIFY ARCHITECT IN WRITING OF DISCREPANCIES. 6. INCOMING TELEPHONE/DATA UNES(4) SHALL TERMINATE IN TERMINAL BLOCKS LIGHTING FIXTURE (LUMINAIRE) SCHEDULE TYPE STYLE MFR./CATALOG NO. NO. LAMPS TYPE WATTS I VOLTS I MOUNTING NOTES A EMERGENCY LITHONIA 4.3 LED 4.3 120/277 WALL OR EMERGENCY. BLACK FINISH ELM-6 LED SUSPENDED SUSPEND CEILING MTD UNITS STRUCTURE B EXIT LITHONIA 4.3 LED 4.3 120/277 SURFACE EXITSIGN LQHM LED B R HO RO C 18" LED HIGH BAY ELT LIGHTING 27 LED 27 100-277 HANGING RING MT. STUSSER ELECTRIC, ALEX - 206-623-1501 T.B.D. D 2'X4' TROFFER MATCH EXISTING (3) 32 W 96 120/277 RECESSED ACRYLIC LENS E FLUSH MT. CEILING LAVARDIN 1-LIGHT 13 120 SEMI -FLUSH MT. SEE NOTE #4 BELOW LED-3000KCOMPATABLE P CUSTOM PENDANT T.B.D. LED - 3000K 18 120 SURFACE AQUA INSULATOR SHADE R 6" RECESSED CAN HALO PD6V120 HOUSING 16 LED - 3000K 16 120 RECESSED MINKA LAVERY GT100-F 6" EFFETRA GLASS TRIM LU L ALL MNJIFAoWMf ,, SMEs, COLORS, SPECS ETG UN OWLR S.YEPoFT ALL Wncl LOCATIONS WIN P R 3.1 DRIFT AYY AND ALL NIGHT LIGHT LCCAm UN CLLNER a�umyrmr=omrorouas-�j.crarcl�papneveralnd-Ilgn.a,woor-aaa�l.Taw,-�a¢.Im,Ifxeanlmlplw.LEo-zmmzlc ADJACENT TO P.O.S. BACKBOARD. (EXI51 7. REMOVE ALL EXISTING ELECTRICAL NOT NOTED TO REMAIN AND/OR NOT REQUIRED BY NEW WORK. (EXIST EXISTING ELECTRICAL ITEMS THAT ARE TO REMAIN SHALL BE REROUTED AND RECONNECTED AS REQUIRED BY NEW TENANT SPACE DESIGNS. 8. ALL SWITCHES (LIGHTS, EQUIPMENT ETC.) TO BE INSTALLED IN APPROPRIATE LOCATIONS, ACCESSIBLE TO APPROPRIATE AREA, VERIFY WITH OWNER ANY CONFLICTING SWITCH LOCATIONS. 9. RESTROOM SWITCH. TO HAVE OCCUPANCY SENSORS 10. SERVICE AREA SWITCHES TO BE MOUNTED AS DETAILED 11, ALL EQUIPMENT OUTLETS AND SWITCHES TO BE LABELED WITH TYPE WRITTEN, SELF-ADHESIVE LABELS. 12. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL POWER CORDS AS REQUIRED FOR EQUIPMENT AND MAKE FINAL CONNECTIONS. 13, ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL TIMER FOR EXTERIOR SIGNAGE. LOCATE TIMER CLOSE TO PANEL. 14. CONTRACTOR TO WRAP & TIE CORDS TO BACK OF INTERIOR SIGNAGE 15. CONTRACTOR SHALL ANCHOR ALL CEILING MOUNTED RECEPTACLES TO BUILDING STRUCTURE 16. SOME MILLWORK MODULAR COMPONENTS MAY BE SUPPLIED WITH OUTLETS, USE OUTLETS IN THOSE COMPONENTS FIRST BEFORE ADDING NEW ONES. 17. PROVIDE P.O.S./PHONE DATA LINES. VERIFY REQUIREMENTS. RUN IN CONDUIT AND TERMINATE AT BACKBOARD INDICATED IN WORKROOM, PPNEL — C--- LOCATION. SERVING:— _-- 120/208 225 VOLT 3 AMPWITHMAIN PHASE 4 WIRE CIR UITBREAKER _---- CRK 10AD DESCRIPTION CODE VA CB/P PHASE CB/P VA ICODE LOAD DESCRIPTION CRK 1 1 STOREFRONT SIGN A 20/1 1440 SODA DISPENSER(129) 2 1 3 STOREFRONT LIGHTING 20/1. B 2012 2028 K HOT WATER DISPENSER (130) 4 5 C 2028 K 11 6 7 HOUSE RECEPTACLES R 720 20/1 A 20/1 960 K FOOD WARMER (135) 8 9 B 10 11 C D VAVCONTROLS 12 13 A 1 14 15 B 20/1 660 K FOOD WARMER (134) REFRIG (133) 16 17 C 18 19 A 2012 1440 K ICEMACHINE(132) 20 21 B 1440 K II 22 23 C 24 25 A 26 27 B 28 29 C 30 31 A 32 33 B 1 1 34 35 C 36 37 A ELECTRIC HEAT STRIP 38 39 B II 40 41 C 42 ' PHASEA= 16425 PHASES = 17689 PHASE 12 ' LOAD TYPE L I R I M H AC I D K E WH LM TOTAL LOADS CONNECTED LOAD: 0 720 0 0 0 0 8556VA AMPS DEMAND LOAD: 0 720 0 0 0 0 8556 0 150 9426 VA I AMPS REMARKS _ PANEL IS EXISTING - MODIFY CIRCUITING AND ADD/REMOVE BREAKERS AS REQUIRED (EXIST) ;EXIST) (EXIST (EXIS1 (EXIST (EXIS1 (EXIS1 (EXIST (EXIST (EXISI (EXIST (EXIST (EXIST (EXIST (EXIST (EXIST (EXIST PANEL --_f'�-�— LOCATION: -- SERVING: --_-_—_---_� —f{ 1201208 225 VOLT 3 AMP WITH MAIN: PHASE 4 WIRE CIRCUIT BREAKER CRK LOAD DESCRIPTION CODE VA CB/P PHASE CB/P VA CODE LOAD DESCRIPTION CRK 1 OFFICE/STORAGE RM RECEPTACLES R 600 20/1 A 20/1 600 K REFRIGERATION UNITS (30)(841 2 3 CORRIDOR AREA LIGHTS L 800 20/1 B 20/1 360 K RICE WARMER (29),SUSHI CASE (92) 4 I 5 BIB RACK D 360 20/1 C 20/1 1560 K MICROWAVE OVEN (83) 6 1 7 DINING AREARECEPTACLES R 540 20/1 A 20/1 600 K REFRIGERATION UNITS (30) (84) 8 i 9 DINING/BATH RECEPTACLES R 720 20/1 B 2011 360 K RICER WARMERS (29). 10 i 11 ENTRY RECEPTACLES R 360 20/1 C 2011 t= K REFRIGERATION UNITS (30) (84) 12 13 HEAT LAMPS(81) L 400 20/1 A 20/1 360 K RICEWARMER (29),SUSHI CASE (92).. 14 15 PHONE RECEPTACLE D 500 20/1 B 2011 1560 K MICROWAVE OVEN (83) 16 17 KITCHEN RECEPTACLES R 540 20/1 C 20/1 1560 K MICROWAVE OVEN (83) 18 19 KITCHEN RECEPTACLES 20/1 A 2011 380 D GAS WATER HEATER 20 21 REFRIGERATION UNITS (65) (67) 20/1 B 2011 1560 K MICROWAVE.OVEN (83) ' 22 23 C 24 25 COOLER/FREEZER DOOR HEATERS A 30/1 D HAND DRYER 26 27 JD400 B 30/1 D HAND DRYER 28 29 POS PRINTER (57) DEDICATED 20/1 C 30/2 D IHP-1 30 31 POS PRINTER(57)DEDICATED 20/1 A J2200 D IHP-1 32 33 POS PRINTER (57)DEDICATED 20/1 B 3012 D OHP-1 34 35 POS PRINTER (57)DEDICATED 20/1 C D OHP•1 36 37 POS PRINTER (57) DEDICATED D 400 20/1 A 38 39 POS PRINTER (57) DEDICATED D 400 20J1 B 40 41 C 42 PHASEA=) 16425 PHASEB=) 17689 PHASE _) 18612 ' LOAD TYPE L R M H AC D K E WM LM TOTAL LOADS CONNECTED LOAD: 1200 3300 D 0 0 19480 10100 0 34080 VA AMPS DEMAND LOAD: 1500 3300 0 0 0 19480 10100 0 310 34690 ( VA 96 1AMPS REMARKS: PANEL IS EXISTING- MODIFY CIRCUITING AND ADD/REMOVE BREAKERS AS REQUIRED PANEL LSERMNG: — �—_ I 22508 AMPWITH.MAIN:PH RCUIT BREAKER E ASE CRK LOAD DESCRIPTION CODE VA CB/P PHASE CB/P VA CODE LOAD DESCRIPTION CRK 1 KITCHEN HOOD D - A COOLER UNIT 2 3 KITCHEN HOOD D B COOLERUNIT 4 5 KITCHEN HOOD D C FREEZER 6 7 HOOD LIGHTS L. 400 2011 A .FREEZER g 9 HOOD FIRE & CONTROL PANEL D 1200 . 20/1 S 10 11 C 20/2 1120 K BEER COOLER COMPRESSOR 12 13 SODA DISPENSER (129) K 1440 20t1 A 20/1 1120 K 14 15 HOT WATER DISPENSER (130) K 2028 2011 B 20/1 864 K COOLER COIL, LIGHTS 16 17 II K 2028 20/1. C 20/1 864 K -15. 18 19 FOOD WARMER (135) K 960 20/1 A 20/1 1044 K SODA GUN (110), COOLER (115) 20 21 FOOD WARNER (134), REFRIG (133) K 660 20/1 B 20/1 852 K GLASS CHILLER (118) 22 23 KITCHEN DISHWASHER C 20/2 1248. K DISHWASHER(112) 24 25 A 1248 K II II 26 27 B 28 29 ROOFTOP GASfELECTRiC UNIT C 30 31 ROOFTOP GAS/ELECTRIC UNIT A ROOFGFCI 32 33 ROOFTOP GAS/ELECTRIC UNIT B 34. 35 C 36 37 A 38 39 B 40 41 C 42 PHASEA=) 16425 PHASEB=) 17689 PHASE = 18612 LOAD TYPE L R M H AC D K E WH LM TOTAL LOADS CONNECTED LOAD: 400 0 0 0 0 1200 15476 0 17076 VA AMPS DEMAND LOAD: 500 0 0 0 0 1200 15476 0 150 17326 VA AMPS REMARKS_ PANEL IS EXISTING -MODIFY CIRCUITING AND.DIREMOVE BREAKERS AS REQUIRED PANEL LOCATION: LP SERVING 120/208 225 VOLT 3 AMPWITHMAIN: PHASE 4 WIRE CIRCUITBREAKER CRK LOAD DESCRIPTION CODE VA CB/P PHASE CB/P VA CODE LOAD DESCRIPTION CRK 1 DINING 104 LIGHTING 800 A 1200 - TIMECLOCK 2 3 FOOD PREP COUNTER LIGHTING 440 B 1200 TINE CLOCK 4 5 FOOD PREP LIGHTING 600 C 700 WINDOW AREA LIGHTING 6 7 DINING 107 LIGHTING 800 A EXISTING 8 9 BAR 105 LIGHTING 660 B EXISTING 10 11 EXISTING C EXISTING 12 13 EXISTING A 340 HOSTESS AREA LIGHTING 14- 15 B 600 CENTER DINING LIGHTING 16 17 DINING 110 LIGHTING 600 C 18 19 SERVER 111 LIGHTING 240 A EXISTING 20 21 B EXISTING 22 23 EXISTING C EXISTING 24 25 A 26 27 B 28 29 C 30 31 A 32 33 B 34 35 C 36 37 A 38 39 B 40 41 42 ' PHASEA=I_ PHASEB= _J PHASE LOAD TYPE L R M H AC D K E WH LM TOTAL LOADS CONNECTED LOAD: 0 0 0 0 0 0 0 0 0 VA AMPS DEMAND LOAD: 0 0 0 0 0 0 0 0 VAAMPS REMARKS.____ PANEL IS EXISTING -MODIFY CIRCUITING AND ADDIREMOVE BREAKERS AS REQUIRED (EXIST) m (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) EXIST) RECEIVED CITY OF TUK{1VILA JAN 17 2019 PERMIT CENTER wfqls\� R\�w All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, appp��Q�� I developed for use on, and in connection with the. specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed Eli" any person, Firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. B 11� AMA J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 — FAX glen®gam I I lerarch Iteoture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON �'" :REGISTERED GIEMA. IL� 1 SPATE OF WA381NGTBN TRAPPER'S SUSHI T1 SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. if %MOO too SUSHII C2 OI/II/19. LANDLORD/ADDENDUMM I2lI6/I8 CORP/OWNER REVIEW MARKI DATE I DESCRIPTION JOB NO.: FILE: SY: PLAN CHECK NO. PERMIT NO. DATE: ® copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE ELECTRICALZ EDULES CODE C0 „ L➢ANCE APPROVED FEB 2 8 2019 City of Tukwila SHEET OF VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN RANGINCUSUPPORTING HVAC EQUIPMENT. DUCTWOOK PIPING, WATER HEATERS, TRANSFORMERS, FIXTLIRES, CONDUIT, ETC. WITH LANDLORD AND TENANT'S ARCHITECT. ATTACHING TO LIPPER LEVEL FLOOR SLAM OR ROOF DECK IS NOT ALLOWED.'DONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS" ETC. SHALL BE FASTENED TO BAR MISTS OR BEAiJIS- THIS SUPERSEDES ANY AND ALL NOTES ON PLANS W REFERENCE TO LANDLORD"SWORK: NOT WITHSTANDING ANYTHING TO THE CONTRARY WITHIN THESE PLANS AND OTHERWISE SET FORTH 04 THE EXECUTED LEASE; THE TENANT ACCEPTS THE LEASE PREMISES AND ALL HVAC, ELECTRICAL. PLUMBING AND FIRE PROTECTION SYSTEMS "AS IS7 AND THIERE IS NO LANDLORD WORK. mi 2 3/4' EXISTING 3 TON SPLIT SYSTEM HEAT PUMP SERVING KITCHEN WORK ROOM, OFFICEA AND RESTROOMS TO REMAIN (E) �1 ` GRIDDLE HOOD, FIRE CONTROL SYSTEM AND MAKE-UP AIR PANEL PROVIDED BY CAPTIVEAIRE AND INSTALLED BY CONTRACTOR, SEE CAPTIVEAIRE SHOP DRAWINGS (ETR) FOR EQUIPMENT DETAILS. PROVIDE FIRE WRAP ON ALL NEW NEW AND ALTERED GREASE EXHALE DUCTS CONNECT. TO QH_� EXISTING DUCT (ETR) (E) COMMON E IT CORRIDOR _O . EXIOSTING DISHWASHER EXHAUST SYSTEN TO REMAIN (( R (E )_Al2OVE (E) MEN 774 EXISTING RESTROOM EXHAUST SYSTEM TO REMAIN HV,4C FLAN SCALE, 1/4" - V-0" Eb_� E O—D (ETR) DINING 104 II , r--1 II I O 10"0 CD I j 10"D CD 335 CFM II 335 CFM 10"0 O; O HOOD MAKEUP ( ( AIR PLENUM , A , �� 1 1 � I I L_J 1 O _ - L 2„m I L_ J 1 1 I 10"0 o - t 10"0 CD I 10"0 CD 335 CFM ( 335 CFM O t-J -OOD PREF. REMOVE PORTION OF EXISTIN SUPPLY DUCT AND REPLACE ii W/ NEW SECTION. NEW EXPOSED DUCTWORK TO BE SPIRAL TYPE L_J 1 1 1 I I 6/\d O O BAR 105 10"0 CD 10"0 335 CFM O O 0 EXISTING EXPOSED SUPPLY AND R5TNfdN DUCTS AND DISTRIBUTION �TO REMAIN EXCEPT WHERE THERWISE 0 CONNECT TO �- EXISTING DU( O Oi 1 O-----�......... 1 I 1 10"0 335 CD 335 CFM 10"0 CD ( I CONNECT TO - 335 CFM �� EXISTING DUCT O �. 20"00 (ETR) �______________ - ENTRY 108 1105TESS H grease exh \\\/ \\\/// STN. � tl 22"0 hood muc _ -- -- L_ EF-11 E3 _ (ETR) = J I I COUN 110g DINING n 7EXG4 TON r -----UNIT TO --- - - N. REPLACE I ALL SUPPLY DUCTS WITH NEW SPIRAL TYPE (ET 18"0 14'0 12"0 \J 1 EXPOSED SPIRAL DUCT __ WOMEN I 240 C WSR 115 1 --- 240 CFM DINING - - - - - - _ _ (ETR) (ETR) (ETR) (ETR) TYPICAL OF 6 .iii_t_1_Q ---_ 6"0 CD -__ 150 CFM I- --a 0 -- 0 0 0 0> o Z TRVER STN. I - 111 7 EXISTING UCT UP TO _ _ _ _ _ _ _ EXISTING 00 OR RE I' EO E U EN C17Y a61 KM NEw T — 0 JA 1 201 THERMOSTAT N � � 1 N of MI v PrG,h4wn vrA` All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved U, �C developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to ang person, Firm, or corporation for any purpose whatsoever without permission of G. A. Miner Architecture. J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 — FAX glen®gomi I lerarchltectvre.com CONSULTANTS MATHEWS CONSULTING RAL CONTRACTOR: EGE MPRECISION PUYALLUP, WASHINGTON TERED 41114F')RGCRj1TT , GLEN "A; ILL" STATE DE WASNINCTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. PNP PI f -t SUSHI C2 0I/11/19 LANDLORD/ADDENDUMM 12/I6/18 GORP/OWNER REVIEW MARK DATE 1 DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: 0 copyright 2013 6A MILLER ARCHITECTURE SHEET TITTLL Ea m SHEET OF EXISTING FLOOR/CEILING ASSEMBLY EXTREND TO EXISTING MAKE UP AIR SUPPLY DUCT EXTREND TO EXISTING GREASE DUCT 18"0 ATTIC SPACE 16 ga 22"0 t PROVIDE ONE HOUR FIRE WRAPON GREASE DUCT CEILING STAINLESS STEEL WHERE ST. STL.COLLAR AROUND EXPOSED CEILING PENETRATION GRIDDLE HOOD - SEE CONNECT GREASE AND MAKE-UP CAPTIVEAIRE DETAILS DUCTS TO HOOD _INSTALL HOOD CONTROL PANEL AND PROVIDE INTERFACE CONTROL WIRING PER CAPTNAIRE REQUIREMENTS SECTION AT GRIDDLE HOOD NOT TO SCAIE m LANDLORD/TENANT CONSTRUCTION NOTES CONTRACTOR SHALL VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN HANGING/SUPPORTING HVAC EQUIPMENT; DUCTWORK, PIPING, WATER HEATERS, TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANT'S ARCHITECT. ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. HANGERS, CLAMPS, SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. ITEMS PLACED ON ROOF: 13ENANT'S GENERAL CONTRACTOR, AT TENANT'S EXPENSE, SHALL BE REQUIRED TO FURNISH TEMPORARY WEATHERPROOFING FOR ALL ROOF PENETRATIONS, UNTIL LANDLORD'S ROOFING CONTRACTOR HAS: MADE FINAL WEATHERPROOF PATCHES, AT TENANT'S EXPENSE. TENANT'S STORE SPACE NUMBER SHALL BE PERMANENTLY STENCILED ON ONE SIDE OF ANY ROOF -MOUNTED HVAC UNIT, WITH MINIMUM THREE-INCH (3") HIGH LETTERS. 2.ALL ROOF AND SLAB PENETRATIONS MADE BY TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO LANDLORD'S STANDARD CRITERIA AND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS, WEATHERPROOFING OF ANY ROOF PENETRATIONS REQUIRED BY TENANT SHALL BE PERFORMED BY LANDLORD'S AUTHORIZED ROOFING CONTRACTOR. TENANT'S GENERAL CONTRACTOR SHALL PAY ALL SUCH COSTS, THEREFORE, DIRECTLY TO SUCH ROOFING CONTRACTOR UPON THEIR DEMAND. ANY FAILURE TO FOLLOW THIS PROCEDURE, AND ANY DAMAGES RESULTING THEREFROM, SHALL BE AT THE TENANT'S SOLE COST AND EXPENSE. 3.INSTALL ALL DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE. ROUTE TO AVOID LIGHT FIXTURES. MAINTAIN DUCT HEIGHTS TO ACCOMMODATE CEILING HEIGHTS, REFER TO REFLECTIVE CEILING PLAN. THE ABOVE NOTES SUPERSEDE ANY AND ALL NOTES ON PLANS IN REFERENCE TO LANDLORD'S WORK: NOT WITHSTANDING ANYTHING TO THE CONTRARY WITHIN THESE PLANS AND OTHERWISE SET FORTH IN THE EXECUTED LEASE, THE TENANT ACCEPTS THE LEASE PREMISES AND ALL HVAC, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEMS "AS IS" AND THERE IS NO LANDLORD WORK THE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT SHALL BE VERIFIED WITH LANDLORD PRIOR TO PLACING ITEMS ON ROOF. VENTILATION DATA AIR BALANCE AC SUPPLY AIR law CFM MAKE UP AIR SUPPLY — 2550 CFM TOTAL SUPPLY: 10650 CFM RETURN AIR (80 0) 6000 CFM HOOD EXHAUST AIR 3200 CFM DISHWASHER EXAUST AIR— 600 CFM RESTROOM EXHAUST AIR— 30(DCFM TOTAL RETUIRVEXHAUST 5630 CFM NET POSITIVE PRESSURE— 550 CFM SOUND UNDED PLENUM ATTACH TO DIFFUSER NECK WITH SCREWS SQUARE TO ROUND NECK CEILING NOTE: DO NOT LOCATE VOLUME DAMPERS ABOVE GYPBOARD CEILINGS FLEX DUCT SAME SIZE AS DIFFUSER NECK CLAMP -I CEILING DIFFUSER CEILING DIFFUSER DETAIL (CEILING RETURN5 SIMILAR) MECHANICAL LEGEND 24/48 FLEXIBLE DUCT CONNECTION 4 TURNING VANE SUPPLY DUCT UP RETURN DUCT UP �. SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME. DAMPER (VD) OEQUIPMENT CALL OUT QT THERMOSTAT 7757 RETURN AIR GRILLE (RAG) DUCTWORK THRU ROOF -+- -"- CEILING. DIFFUSER (CD) (ETR) EXISTING TO REMAIN CONICAL SPIN -IN FITTING SUPPLY DUCT HVAC NOTES: 1. INSTALL ALL WORK IN ACCORDANCE WITH STATE AND LOCAL CODE REQUIREMENTS. 2. INSULATE ALL NEW SUPPLY AND RETURN AIR RECTANGULAR DUCTS WITH 1" DUCT LINER. CONCEALED ROUND DUCTS SHALL HAVE DUCTS SHALL HAVE 1" EXTERIOR WRAP. DO NOT INSULATE EXPOSED SPIRAL DUCT. INSULATION VALUES PER WSEC. 3. THE .USE OF FLEXIBLE DUCT IS LIMITED TO THAT SHOWN, NO ELBOWS. FLEX DUCTS .SHALL BE FACTORY INSULATED ,L ALL DUCTS SHALL BE SEALED WITH DUCT SEALER SIMILAR TO UNITED SHEET METAL DUCT SEALER. 5. PROVIDE TESTING AND BALANCING FOR ALL NEW AND EXISTING AIR SYSTEMS. SUBMIT REPORTS TO ARCHITECT. 6. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF MAJOR MECHANICAL EQUIPMENT PRIOR TO ORDERING. 7. SEE ALL OTHER DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL WORK AND CLARIFICATIONS OR WORK TO BE PERFORMED. 8, LOCATE EXHAUST DISCHARGES A MINIMUM OF 10'-0" FROM AIR INTAKES. FIELD VERIFY LOCATIONS. 9. ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS. SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. MAKE ALLOWANCE FOR INTERNALLY LINED DUCTWORK. 10. RELOCATE AND RECONNECT EXISTING THERMOSTATS AND CONTROLS AS REQUIRED. CONTROL, PROVIDE REMOTE SENSORS AND LOCKING COVERS it. CONNECT NEW SUPPLY AND RETURN DUCTS TO EXISTING UNIT DUCTWORK DISTRIBUTION .SYSTEM. 12. ALL EXPOSED DUCTWORK SHALLSPIRAL .WOUND AND BE FACTORY FINISHED - BLACK COLOR. 13. REMOVE ALL EXISTING MECHANICAL NOT NOTED TO REMAIN AND/OR NOT REQUIRED BY NEW WORK. EXISTING MECHANICAL ITEMS THAT ARE TO REMAIN SHALL BE REROUTED AND RECONNECTED AS REQUIRED BY NEW TENANT SPACE DESIGNS. RECEIVED CITY OF TUKWILA JAN 17 2019 PERMIT CENTER av All concepts, designs, arrangements, and data indicated on these documents are the property of Cs. A. Miller Architecture and were created, evolved developed for use on, and to connection with the specified protect. None of such ideas, designs, arrangements, or data shall be used by, or disclose any person, firm, or corporation for any purpose whatsoever without permission ofG. A. Miller Architecture. j . rA pil A 1A NII o o , A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503,636.9898 — FAX glen®c3oml I lerorchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON STEREDyy��TGLEN"A. ILM LR qF�;ARCH[IT STATE'OF WASIIINGTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. ASP Ptr SUSHI Ca O111/L9 LANDLORD/ADDENDUM#I 12/16/15 GORP/OWNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO, PERMIT NO. DATE: 0 copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE H l DEEM S A 4'RO ED FEB 28 fC19 City of Tukwila r. SKEET OF PLAN NOTES OCONNECT TO EXISTING GREASE WASTE LINE BELOW FLOOR OCONNECT TO EXISTING 120° HOT WATER LINE ABOVE CEILING OCONNECT TO EXISTING COLD WATER LINE ABOVE CEILING ®CONNECT TO EXISTING 3" VENT ABOVE CEILING OCONNECT TO EXISTING 2" VENT ABOVE CEILING ©CONNECT TO EXISTING 2-1/2" GAS LINE ABOVE CEILING .5 L M N G _ � EXISTING WAT R ❑ SERVICE AND DINING - VALVES 104 (E) ELEC. STOR. (E OFFICE - 02 03 6 1 �, = a N 3"-1 w STORAGE. I I = O2930 GAS EMERGENCY AN 129 3 MANUAL VALVES +22 I I I EXISTING _ +22" _ _ EXISTING BEER COOLER FD. 2„ EXISTING �I 3 EXISTING 5 -- - I _ ' -G -_ _ _ ..._ 4"� 2 II Ji ,1 6 EXISTING ( 4'" EXISTING F �' - ----------------------- ---------- GIN 'tp ; F0F0 p j GW ______'Gyp ______ _ II 34 a a6" 1 I RUN WATER A D VENT I �' TI�IHEADER 1-1/2" GAS ; ; 71 \ ", N; ( LINES BELOW OOR (I. 6 LFL�'1j 1BAR 34 MB 1 1 117 - FD C EXISTING WATER HEATER i i r— (E) COMMON EXIT CORRIDOR EXIT CORRIDOR 00 116 (E) MEN 114 ❑3 105 50 MBH *30' 69 i- 2 - 1 _ .30° 68 I t l I I j I I =FD j� L --- ___ - ---- 1 1 -H USE tti I j 111 12" 11 0 12 106 05 MB 4 sm 66 1 9108112 ;I ill 105 MB 11 DINING I I I I I I I I I I I I) EXISTING GWGW ti r—- - - - - - - - J N _ — - ENTRY Lj Li ET 1 108 Lj HOSTESS 3 3 &TN. I EXISTING I 2 F i EXISTING {E) ALCOVE , 1 a 17z ® I Fs 129 MEN 12922' --------- 115 I r- 30 _-------� COUNTER DINING IE i 109. L- E:B IF I_______7 J, I ® 2 25 - 2"I 1+24' 126 -_ --1 V ............ DINING SERVER STN. ' � 170 L- I - 17 I L ommi ........... - -------- T2' 132-------i -- I IE f=�f= ff�ff� ff=lf�l FLfi LAN -FD I a� z FS-------;1 1 1 2019 SCALE: I/4" - p_0,� 132 G ER I CENTER 9 8 All concepts, designe, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, developed for use on, and in connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to any person; firm, or corporation For any purpose whatsoever without permisslon of G. A. Miller Architecture. j1� r . A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636,7979 503,636.9898 — FAX 91en@9ami l lerorohitectvre.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON REGISTERED ARCI{IT T GLf ILLER STATE OF WASHINGTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. �� AgrP Ptwo > SUSIAI C2 0I/II/11 LANDLORD/ADDENDUM## 12/16/18 CORP/OWNER REVIEN --MARKJ DATE I DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: ® copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE PAN FEB 2 B £;;9 City of Tukwila SHEET OF PLUMBING GENERAL NOTES 1. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND MAKE ADJUSTMENTS AT NO ADDITIONAL COST TO OWNER. 2, THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING W/ LANDLORD REQ'MTS. AT NO EXTRA COST TO THE OWNER. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID, NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE THE CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND/OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS SUB -BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR RESOLUTION. 4, ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. 5. PROVIDE ACCESS PANELS AS NEEDED TO ACCESS VALVES,EQUIPMENT, ETC. LOCATED ABOVE GYP. BD. CEILINGS. 6. PROVIDE TEMPORARY COVERS, CAPS, OR PLUGS IN SANITARY SEWER SYSTEM THROUGHOUT CONSTRUCTION. RAG WADS, DUCT TAPE OR OTHER MAKE SHIFT CAPS ARE NOT ACCEPTABLE. UPON COMPLETION OF CONSTRUCTION, COMPLETELY TRUCTION, COMPLETELY REMOVE ANY AND ALL OBSTRUCTIONS INSIDE THE DWV SYSTEM; NEW AND EXISTING LINES, BY SNAKING, RODING, OR JETTING THE SYTEM IMMEDIATELY PRIOR TO THE PROJECT TURNOVER TO THE OWNER (TENANT). 7. THE CONTRACTOR SHALL PROVIDE A MIXING VALVES SET AT 110- F. FOR ALL LAVATORIES AND HAND SINKS. MIXING VALVE SHALL BE POWERS E480 OR APPROVED. 8. PIPE RELIEF CATCH PAN FROM WATER HEATER TO MOP SINK, MAINTAIN A 2" MINIMUM AIR GAP. PROVIDE A CATCH PAN UNDER WATER HEATER AND EXPANSION TANK. 9. CONNECT NEW SANITARY SEWER SYSTEM TO EXISTING SANITARY SEWER OF EQUAL OR GREATER SIZE, VERIFY EXACT LOCATION, SIZE, AND INVERT ELEVATION OF EXISTING SANITARY SEWER PRIOR TO STARTING WORK. FIELD ADJUST NEW INTERIOR SANITARY ROUTING AS NECESSARY TO CONNECT TO EXISTING SANITARY SEWER WHILE MAINTAINING REQUIRED SLOPE. 10. INSTALL NEW WATTS 1/2" LF009 REDUCED PRESSURE BACKFLOW DEVICE FOR THE BEVERAGE DISPENSER AND TEA BREWER. 11. REFER TO ARCHITECTURAL PLANS FOR PLUMBING DEMOLITION WORK, IF ANY, AND NOTES. 12. SEE RESTAURANT EQUIPMENT SCHEDULE ON THE ARCHITECTURAL PLANS FOR EQUIPMENT PROVIDED BY OTHERS. THIS CONTRACTOR SHALL CONNECT WASTE, VENT, AND WATER TO EQUIPMENT FURNISHED BY OTHERS AND THIS CONTRACTOR SHALL INSTALL FAUCETS AND MISC. FITTINGS FOR A COMPLETE INSTALLATION. 13, SEE ALL OTHER DRAWINGS IN THIS SET AND SPECIFICATIONS FOR WORK REQUIRED OR CLARIFICATIONS FOR NECESSARY WORK 14. CONNECT NEW DOMESTIC WATER TO EXISTING LINE- VEIFY LOCATION AND REQUIREMENTS. 15. VALVES SHOWN SHALL BE BALL VALVES, OR EQUAL, RATED FOR 125 PSI WORKING PRESSURE. 16, ALL NEW WATER PIPE ABOVE GRADE SHALL BE TYPE 1" COPPER PIPE AND FITTINGS. PEX PIPING MAY BE USED IN LIEU OF COPPER IF ALLOWED BY LOCAL CODES. 17. ALL NEW HOT COLD AND RECIRCULATING WATER PIPING SHALL BE INSULATED WITH 1" THICK FIBERGLASS INSULATION, ASJ, VAPOR BARRIER. 18. ALL EXPOSED PIPING TO PLUMBING FIXTURES SHALL BE CHROME PLATED. STOPS SHALL BE PROVIDED WITH REMOVABLE TYPE HANDLES, 19. PROVIDE 12" LONG AIR CHAMBERS AT EACH PLUMBING FIXTURE, OR OTHER CODE APPROVED DEVICE. 20. EXTEND PLUMBING VENT UP THRU ROOF TO APPROVED VENT TERMINATION. LOCATE MINIMUM OF 10 FEET FROM ANY O.A. INTAKE AT THE ROOFTOP UNITS. 21. EXTEND WASTE FROM 3 COMPARTMENT SINK TO DRAIN IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. 22. ICE/DRINK DISPENSER BACKFLOW PREVENTOR MAY REQUIRE SEPERATE PERMIT AND TEST CERTIFICATE 23. REMOVE ALL EXISTING PLUMBING NOT NOTED TO REMAIN AND/OR NOT REQUIRED BY NEW WORK. EXISTING PLUMBING ITEMS THAT ARE TO REMAIN SHALL BE REROUTED AND RECONNECTED AS REQUIRED BY NEW TENANT SPACE DESIGNS. 'FOE' OEM EXIPNQ TO REMAN ®I���IOI •' ' A Sol• �I�•�I�I ���I�®I 01���10 . REMAIN FAUCET EX16TING TO REMAIN �I���Ivl •' � - - I��e��l CLEAN DISH TA15LE- 6W E ISTI T REMAN �ICCMIIIII[IIIIiI 01�•�101 -- - - I���I�� ml►•o�lol -.. Is�sl���l ml►°•��101 •- - - I���I���I ill►•��l©I - - ���I®�S!!%Z�I WITH sitgzE �I��►:.�Ipl •• O _I�OI MliiE WON VERIFY RE011REMENT6 OF OLNER PROVIDED EQUIPMENT ®Ir.��101 - I�®®I��I • - �II•��I�_I PLUMBING LEGEND --- COLD WATER PIPING ---- HOT WATER PIPING —F— FILTERED WATER PIPING — — EXISTING SANITARY SEWER PIPING WASTE/SANITARY UNDER FLOOR — -- VENT PIPING —G— GAS PIPING ---0 FLOOR CLEANOUT --II WALL CLEANOUT ® FLOOR DRAIN --04— GATE VALVE --Ci4-- BALANCING COCK f CHECK VALVE —C4— BALL VALVE f HB HOSE BIBB REMARKS: PLUMBING FIXTURE SCHEDULE MARK ITEM MANUFACTURER MODELNO UTILITIES REMARKS CW HW VT WC WATER CLOSET EXISTING V, - 3" 2" LAV LAVATORY EXISTING 1/2" 1/2" 1 1/2" 1 1/4" UR URINAL EXISTING 3/4" - 2" 2" FS FLDOR SINK WADE WADE W-9140 W 3 4" GRATE - - 2" 2" IPROVIDE SLOAN FLUSH VALVE FD FLOOR DRAIN WADE WADE W-1100 W N.BRONZE STRNR - - 2" 2" IPROVIDE TRAP PRIMERS WATER HEATER EXISTING 1" 1" RECEIVED CITY OF TUKIVILA JAN 17 2019 PERMIT CENTER P��p'CL CcH P saigiP All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and In connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of C.. A. Miler Architecture. J ..AMA 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX g lenogami I I erarchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON �"^ REGISTERED �ARCF(IT T GLEN "A. RULER .' STATE OF WAMINGTON TRAPPER'S SUSHI T,I, SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. a iboo SVS'A) CC 01/11/1-1 LANDLORD/ADDENDUMIN 12116/lb GORP/ONNER REVIEW MARKI DATE I DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: ® wpV[Sht 2013 GA MILLER ARCHITECTURE SHEET TITLE PLU 6.1�G. DETA Co c C ��Qr�CE AV Cva D FCO 28 2319 City o$TUifwila LS SHEET OF I :44° ember 30. 2018 I ._ ....- -H . R VALUE OF WAI K-1N C00( FRS - -_-_- COOLERS MINIMUM OF R-25 FREEZERS - MINIMUM OF R-32 INCLUUF.S FLOORS, NJAL.L.S AND CV:.11INGS FREEZERS FLOORS - MINIMUM OF R-28 20 C�7 9 i. Imommr,111 'PN ROOF / REMOTE LOCATION) COD C sCE Alrc�eduV m SEE ARCHITECTS / ENGINEERS DRAWINGS � 6U a, 62 FEB 2820019 cDI offultwiia GENERAL NOTES BUILDING DDVISSION i IT SHALL OF DE RESPONSIBILITY OF THE GENERAL CONTRACTOR ND ALL SUB-CONFRACTORS TO RIFT TIE ACTUAL SPACE AND MECHANICAL REQUIREMENTS OF ALL ITEMS SHOWN AS FUTURE, NI�, SU°PLIED BY 011 FRS", FTC-; 'IIH THE OWNER PRIOR TO ROUGH -IN AND CONNECTION. THE GENIAL CONTRACTOR SHALL IMMEGATELY INFORM CMA RFS,IFAI RANT SUPIS Y & DLS1'_ D HE OWNER OF ANY RED LINES CORRECTIONS, ui CTC., ON THE, PERMIT PLANS AND OF ANY INSPECTION CORRLCTI-:�NS REOUESIED CONCERNING IT E. DRAWINGS OR EQUIPMENT AS LISTED FOR THIS PROJECT, THE GENERAL CONTRACTOR SFALL PROPLRI,Y SE"..AL.. ALL WALL ANI� FLOOR PENETRATIONS AFTE THE INSTALLATION OF RELATED I EQUIPMENT AND FURNISHINGS TEMS. IT SHALL OF NOTED BY THE GENERAL CONTRACTOR AND ALL CONTRACTORS THAT I HIS ET OF PLANS AND ZHrE P ECE ED ,SUB CONTAINID WITHIN IN NO WAY RELIEVES SAID PARTIES OF TPII::IR ESONSIBILITY TO INVESTIGATE ND COMPLY WITI. ITNAORTU MILA COOLS AND ORDINANCES AND TO PERFORM ALL WORK TO THE HIGHEST STANDARDS W JAN Pry 2019 -,: IRE -RATED SHAFTS FOR EXHAUS TML -_ ___ -r. L_ - w rr,H _ DUCTS, PERMIT CENTER fT SHALL BE THE RESPONSIBP77Y OF EH1 GI Nf:ROL CONTRACTOR 0 PROVIDE WEATHER PR T CLOD FOR ALL ROOF AND A[ I. WALL - .r � C7 �� �N � `. � SUITABLE WALL RACKING AS SHOWN ON TESE PLANS AND AS RIQUI L`( BY TTIF OWNER SHALL.. BE PROVIDED AND INS LLED BY THE GENERAL CONTRACTOR. t> rv. rou VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMLNF SELECTIONS � r • • 1 db :d i • • • • .� (►���� . I in .IlrScri _II_+I I IRS] ■ •IG c'u 51 -H } 8 - ROOF SEE ARCHITF.CIURAL OR MECHANICAL DRAWINGS 59 61 t ELECTRICAL LEGEND 115 VOLT DUPLEX OUTLET SDI 115 VOLT DCO DEDICATED/ISOL TED 0- 208V SPECIALTY OUTLET O JUNCTION BOX COMMUNICATIONS CABLE - VERIFY SPEC'S ® AND REQUIREMENTS WITH OWNEF /OFF SWITCH LIGHT FIXTURE BY K.E.C. AND FTALLED BY -4:JON ELECTRICAL CONTRACTOR VERIFY EQUIPMENT REQUIREMENTS WITH FINA EQl IPMENT SELECTIONS GFCI RECEPTACLES SHALL BE PASS & SEYM UR NO. 2095—W 1 °°` `� ` ;,I�� ELECTRICAL NOTES p s.uyV Lb 1. THE CONTRACTOR SS STEEL.. TLET AND RE EPTACI�-,,, 23 E919 SHALL. PROVIDE AN[l INSTALL STJPR COVERS IN SERVICE AREAS. ( F6 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ANDALL HEAT APE ON DRAIN SINES IN DANGER OF FREEZING city of TQZ,6NI�a 5. THE ELECTRICAL. CONNECTIONS, SPECIFICATIONS ANENSIONS HOWN ON THES ail I - 9i,SG DIVISION ARE FOR FOOD SERVICE EQUIPMENT O�LY. SEE THCHITECT' PLAN SET FOR AL.L OTHER ELECTRICAL REQUIREMENTS FOR THIS ROJECT. W`� 6. AL..L. ELECTRICAL ROUGH -IN WORK AN ALL. FINAL C 10 R ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY CMAFIALL.. BE PEMS E ELECTRICAL vJ CONTRACTOR. 7. UNL.FSS OTHERWISE SPECIFIED IN THE PLANS ORR WRI fT N CONTRACTS, IT SRE(;E$}�iED THE RESPONSIBII_IlY OF THE ELECTRIC L CONTRACTPRPR VI E ALL ELECTRIOWYy OFTUKWI!LA MATERIALS INCLUDING WIRING,SWITCHES, DISCONNEFLEX, C NDUIT, CONTACTORS, TRANSFORMERS, THERMAL OVERLOAD f�ROTECTORS,ETIC S ARTERS, ELECTRICAL�AN 1% 2��9 PANELS, CORDS, PLUGS, COVERS, ETC9. ALL DIMENSIGNS SHOWN ARE FROM GFdID LINES, FINW C)R FINISHED FLdixnilc#SCNTERWCENTER LINE OF ELECTRICAL OUTLET OXES. HEIGHRE 0_ TO BE TAKEN FRPLATFORMS - Z - - --`-F ROUGH -IN LOCATION AND TYPE OF CONNECTION ONIY. THE ELECTRICA CONTRACTAL ROVIDE CIRCUITS AND CONDUIT RUNS ASPER GOOD PRACTICE ANDS DE.11. IT SHALL BE THE RESPONS113,11TY OF1HE ELECTRICO ACTOR TO PROVIDE INTERCONNECT SWITCHING BETWt EN THE KITCHEN EXFIAUST HOOD EXHAUST FANS AND THE KITCHEN MAKE UP AIR SYSTEMS AS REQUIRED PER LOCAL C(DE AND AUTHORITIES.C% 12. IT SHALL BE THE RESPONSIBLITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL �'V CONTACTORS ON ALL ELECTRICAL OUTLET, JUNCTION BOXES, ETC. LOCATED UNDER ANY CLASS I EXHAUST HOOD SO AS TO DISCONNECT UPON ACTIVATION OF THE FIRE SUPPRESSION SYSTEM. 14, THE ELECTRICAL CONTRACTOR SHALL. PROVIDE FUSED DISCONNECTS FOR EQUIPMENT ' HOOK-UPS AS REQUIRED BY CODE AND LABELING. '.. 15. ALL GFCI RECEPTACLES SHALL BE LOCATED IN AN SSESSABLE LOCATION FOR STATIONARY QUIPMENT. niOk 1 � 1 = 1 C =20-11_ 1 I ■ s ■ t _ 3 1Ll LJy'}. ' Fu SNovember 30, 2018 j SODA DISPENSING SYSTEM, STUB U w/ 24" RADIUS ELBOWS. (TYP. EA. -H REMOTE SEE ARCHITECTURAL DRAWINGS 38 ROOF SEE ARCHITECTURAL DRAWINGS I sl i I PLUMBING NOTES ----- _ __ -- - --. . i IT IS THE GENERAL CONTRACTORS RESPON IBIUHY TO SIZE,SUPPLY AND IN L A GREASE INTERCEPTOR/TRAP IF ONE IS REQUIRED. 2. Al FIRE PROTECTION SYSTEM GAS SHUT-Cyl-F VALVES SHALL - LIED BY THE OWNER AND INSTAI_I_ED BY PLUMBING CONTRACTOR, I L, 3. THE PLUMBING CONNECTIONS, SPECIFICATIONS S AND DIMENSIONS SHOW N THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEEM ARCHITECTS PLAN SETT F ALL OTHER .PLUMBING REOUI REMFNTS FOR THIS PROJECT. 4. ALL PLUMBING ROUGH -IN WORK AND FINAL CONNECTIOINS FOR ALL I -MS SF WN AND SPECIFIED ON THESE PLANS BY CUA. REST URANT SUPPLY & DESIGN SHALT_ E PERFORMED BY THE PLUMBING CONTRACTOR. - 6. UNLESS OTHERWISE SPECIFIED IN THESE PLk1NS OR OTHER WRITTEN C NTRAC S, IT SHALL BE HILL RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO PROVIDE ALL NG--TYPE MATERIALS INCLUDING VALVES, TRAPS, LINEN STRAINERS, FLOOR SINK COVE , PRESSURE REGULATORS, SIPHON BREAKERS, ETC. 7.I1 SHALL BE THE RESPONSIBILITY OF THE _NFRAL CONTRACTOR TO VERI THAT THE. LOCATIONS FOR ALL MECHANICAL REQUIRE ENTS WHICH REQUIRE FLOOR _NETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBER IN THE FLOOR. 8 HE GENERAL CONTRACTOR SHALL SO RE E THE LOCATION OF All.FL R DRAINS ON THE JOB SITE SO AS TO ENSURE THE BEST SL PE POSSIBLE OF THE SUER NDING FLOOR TO THESE DRAINS. 9, AI_I_ DRAIN LINES FROM EQUIPMENT REQUIRIJG CONDENSA110N REMOVAL HALL BE RUN IN COPPER. 10. PLUMBING CONTRACTOR TO SUPPLY WATER PRESSURE REDUCING GALS SET AT[?19VPSI FOR, EACH DISHWASHER AND GLASS. WASHER. COO: ®zX k F,IL W PLUMBING LEGEND FEB 2822A O CW COLD WATER City Of Tu" "I1"I ._ —� _ GtALumG �l'F'210N �oF CW COLD WATER FILTERED — RECEIVED Ind. W o Hw HOU WATER CITY OF TIjKWILA uJ ® CLOSED DRAIN DIRECT WASTE LE JAN 17 2019 � -12 x 12 FLOOR SINK — INDIRECT WAS E — -- PERMIT CENTER ® NATURAI- GAS O FLOOR DRAIN , CV ® � j VERIFY EQUIPMENT REQUIREMENTS WITH FINAL. EQUIPMENT SEI ECTiONSJ � i►Wa�u� SIP +I _ eioo 1, • • 1 Project #: 149 s J CONTRACOR TO VERIFY ALL DIMENSIONS CONTRACOR TO VERIFY ALL DIMENSIONS PAINTALL GRID, CEILING PAINTALL GRID, CEILING FURNITURE WALLTILE FURNITURE ALL F.O.H.FLOORS WALLTILE WALLTILE AND TABLES ANDTABLES POLISHED CONCRETE BY OTHERS BY OTHERS 1A TRAPPER'S SUSHI CO. -SOUTHCENTER. INTERIOR ELEVATION -DINING/BRANDWALL-WEST SCALE: 1/4"=1'-0" CONTRACOR TO VERIFY ALL DIMENSIONS CONTRACOR TO VERIFY ALL DIMENSIONS PAINT ALL GRID, CEILING PAINT ALL GRID, CEILING E-t 5" UPPER WALL SECTION PI ALLPANELS IDENTICAL IX6TRANSITION STRIP. PAINT P-2 6PFLATSCoREEENTV i �P 6E"U SCREmEN TV iocer I evowt� 1 FP-3-1 i KITCHEN WALLTILE FURNITURE AND TABLES BY OTHERS 1B TRAPPER'S SUSHI CO. - SOUTHCENTER INTERIOR ELEVATION - WAIT STATION / DINING - NORTH 5CALE:1 /4" =1'-0" MOUNT PICTURE PAINTCEIIJNG P3 FLUSH TO CEILING i ST fiO.F aeROWEE N m PAINTALL GRID, CEILING UPPER WALL SECTION P1 IXBTRANSITION STRIP. PAINT P-2 T fi" -2A LP•2 56°FIAT So EENN 6W T6SCRREEENTV ALL FO.H.FLOORS DECORATIVE GLASSITILE WHITESUBWAYTILE FURNITURE PIAM BAR FRONT S.S. FOOT RAIL POLISHED CONCRETE ANDTABLES WITH S.S. TOE KICK TYP CORIAN BY OTHERS. 1y NP COUNTERTOP TRAPPER'S SUSHI CO. - SOUTHCENTER INTERIOR ELEVATION - SUSHI BAR AND KITCHEN - NORTH SCALE: 1 /4" =1'-0" CONTRACOR TO VERIFY ALL DIMENSIONS WALLTILE ALL FO.H.FLOORS P-LAM BAR FRONT C FURNITURE S.S. FOOT RAIL WALLTILE FURNITURE A11 RO.H.FLOORS FURNITURE 1D POLISHED CONCRETE WITH S.S. TOE KICK 1E ANDTABLES TYP 1F ANDTABLES POLISHED CONCRETE 1G ANDTABLES TYR BY OTHERS BYOTHERS BYOTHERS DECORATIVE GLASS T E TRAPPER'S SUSHI CO. - SOUTHCENTER TRAPPER'S SUSHI CO. - 5OUTHCENTER TRAPPER'S SUSHI CO. TRAPPER'S 5U5HI CO. INTERIOR ELEVATION -WAIT STATION /RESTROOMS-WEST INTERIOR ELEVATION - SUSHI KITCHEN -EAST SOUTHCENTER SOUTHCENTER SCALE:1/4'= T-O" SCALE: 1/4"=1'-0". INTERIOR ELEVATION - PRIVATE DINING -NORTH INTERIOR ELEVATION - PRIVATE DINING -EAST SCALE: 1 /4' =1'-0" SCALE: 1 /4' =1'-0" ,�, BSR BSR BRAND ENVIRONMENT GLEN A. MILLER, RA CSI NCARB 167 HAIDA PL, LA CONNER, WA 98257 GA MILLER ARCHITECTURE PC Restaurant Design Branded Architecture g 206-856-7730 Ken Barnes: Ken@BSRBranding.com LAKE OSWEGO, OREGON Ph: 503.636.7979 © 2018 BSR Brand+Environment OWNER: . JOB NO. TSCO-1C TRAPPERS SUSHI COMPANY / TRAPPER O'KEEFE 718 GRIFFIN AVENUE #940, ENUMCLAW WA 98022 REVISION NO. 6 By. KB PROJECT LOCATION: PLAN CHECK: KS / RH SOUTHCENTER, 468 Southcenter Mall, Tukwila, WA 98188 DATE:• 01/14/15 I FURNITURE ANDTABLES _ WALLTILE BYOTHERS iWi P'+%✓•-� F[2 28281J TRAPPER'S 5U5HI CO. 50UTHCENTER TLl(LVa cUILMING LBIS,CN INTERIOR ELEVATION - PRIVATE DINING - SOUTH SCALE:1/4"= T-O" nEcelvEa CITY OF TUKWILA JAN 17 2019 r PERMIT CENTER SHEET TITLE: DRAWING NO. -- INTERIOR ELEVATIONS MATERIALS AND FINISHES MF `' ■ SHEET I OF 3 CONTRACOR TO VERIFY ALL DIMENSIONS CONTRACOK TO VERIFY ALL DIMENSIONS DECORA' GLA& TILE PAINTALL GRID, CEILING WALLTILE S.S.BACKBAR ALLFO.H.FLOORS CORIAN CABINETS POLISHED CONCRETE COUNTERTOP 1R TRAPPER'S SUSHI CO. - 5OUTHCENTER INTERIOR ELEVATION - BAR - SOUTH FACING SCALE: 1/4"=1'-O" CONTRACOR TO VERIFY ALL DIMENSIONS 42"PONY WALL CONSTRUCTION TOP VIEW BOOTHANDTABLE -2' PAINTALL GRID, CEILING COUNTERTOP WITH S.S. TOE KICK POLISHED CONCRETE TYP ANDTABLES TYP 1 J BY OTHERS TRAPPER'5 SUSHI CO. - SOIJTHCENTE , INTERIOR ELEVATION - BAR- EAST FACING SCALE:1 /4" =1'-O" CONTRACOR TO VERIFY ALL DIMENSIONS 55" PONY WALL CONSTRUCTION TOPVIEW TOOL TABLE p BOOTH SEATING BYJH CARR YX 1" HOTROLLED STEEL U CHANEL FRAME WITH WELDED CORNERS PONY WALL SIDEVIEW END CAP VIEW SIDEVIEW LENGTH VARIES SS WIRE MESH. INSTALL WITH HDWR H 1 S FROM MANUFACTURER CORION FABRICATED CAP SS-3 1.5"THICK-RABBETTOFIT WT-3 - ----- TOP OF PONY WALL G-3 .�.__. CERAMIC TILE-INSTALLhT ONALL INNERAND OUTER FACES 6'-O° 6" 2' 8" 5'-6" 6" BOOTH IS GENERALLY 72"LONG BOOTH WIDTH VARIES END OF SEAT SHOULD BE SETSACK2"FROM PONYWALLEND TRAPPER'5 SUSHI CO. - 50UTHCENTE . CONSTRUCTION 42" PONY WALL - BOOTH - TYP SCALE: 318" =1'-0" Restaurant Design & Branded Architecture TRAPPER'S SUSHI CO. - 5OUTHCENTER CONSTRUCTION 55" PONY WALL - BANQUETTE -TYP SCALE: 5/6"= 1'-0" BSR BRAND ENVIRONMENT 167 HAIDA PL, LA CONNER, WA 982S7 206-856-7730 Ken Barnes: Ken(&BSRBrandinq.COm BANQUETTE SEATING BY JH GARR Yx V HOT ROLLED STEEL U CHANEL FRAME WITH WELDED CORNERS SS WIRE MESH, INSTALL WITH HDWR FROM MANUFACTURER CORION FABRICATED CAP 1.5" THICK -RABBET TO FIT TOP OF PONY WALL CERAMIC TILE, INSTALL ON ALL INNER AND OUTER FACES GLEN A. MILLER, RA CSI NCARB GA MILLER ARCHITECTURE PC LAKE OSWEGO, OREGON Ph: 503.636.7979 PAINTALL GRID, CEILING AND TABLES CABINETS POLISHED CONCRETE BYOTHERS 1K TRAPPER'S SUSHI CO. - 5OUTHCENTER INTERIOR ELEVATION - BAR NORTH FACING SCALE: 1 /4" =1'-O" PAINT ALL GRID, CEILING UPPER WALL SECTION Pt 1X6 TRANSITION STRIP. PAINT P-2 \ ------------------------- u ------------ _____________ � � 4V 18.5" S CON ON FABRICATED 42' 73" S-3 BLA -, DESKTOP-1'THICK _.-- INT OR y g AOUAG ASS LMI - 9 0 - L. IG. __ WALLILES SS.TORIMNSTALL -- - - - - - - SS.4 `N 42" 18" - OWRTILEFACE'------" NOTE: ALL FINiBHESTYPiCpL - SJ .� 42' 72° 1M 1N 1M TRAPPER'5 51J5HI CO. - SOUTHCENTER CONSTRUCTION HOSTESS COUNTERS =TYP SCALE: 516' =1'-O" CONTRACOR TO VERIFY ALL DIMEN51ON5 P-2 ® EXISTING SOFFIT SOFFIT CON NSTRUC I N TO MAF EXG o P'3 LASS ANDM I, M DOOR TO A G WNDOWFINIS SNOCHANGES EN 'uS ORS WINDOW FINISH NO CHANGES $ - EXISTIN 2? IT NK I IA GES �2 R jl�3 ® I 1 1 ® I WALWTILE ALLF.O.H.FLOORS d& FURNITURE POLISHED CONCRETE 1L AND TABLES BYOTHERS TRAPPER'S SUSHI CO. - 50UTHCENTER INTERIOR STOREFRONT ELEVATION - BAR- SOUTH SCALE: 114'=1'-O" TRAPPERS SUSHI COMPANY / TRAPPER O'KEEFE 718 GRIFFIN AVENUE #940, ENUMCLAW WA 98022 PROJECT LOCATION: SOUTHCENTER, 468 Southcenter Mall, Tukwila, WA 98188 REVISION NO. BY: PLAN CHECK: DATE: ALL RO.H.FLOORS FURNItURE POUSHEDCONCRETE AND TABLES 1p BYOTHERS UU TRAPPER'5 SUSHI CO. - SOUTHCENTER INTERIOR STOREFRONT ELEVATION - WAIT SEATING - SOUTH SCA E: FEB 2 ;J CITY Y OF TUKWILA City offulmila JAN 17 2019 PERMIT CENTER TSCO-100118-FW SHEET TITLE: DRAWING NO. -- 6 INTERIOR ELEVATIONS KB MATERIALS AND FINISHES KB / RH 01/14/19 SHEET 2 OF 3 TARANTULA HILL BREWING COMPANY - INTERIORMATERIALS AND FINISHES fj rRxe N x_ ,T 3 T{'"� .qIZ ! i �5i °� _ ,,_.. — r " 2'-5" a, In Z 0. w f —6^hTI� _„• - , .� o,�c' - ` 1L � JI 2So q F10 ..a T a ' — (— �— - •v �_ --- I 41 �n� II _—E�� '° "' "' '" '^ Li Li Li Li Li Li Li Li Li LJ Li Li Li Li UE11j— J ( 1 H 111 — 11 1 C 1 B 1A �---u�---{t�,' F7 / IdEr i 1 � 1,j r COLUMNS IE y _ i 1A 1L ELD 1 N 1 K \Y Cl c E RECEIVED CITY OF TUKWILA FEB 20 2�11 JAN 172019 11L�So`�"Cs L28tP¢c€LSD coCiofi ty TLtI;1vila PERMIT CENTER ITEM MFG MOD 1 NO. COLOR / PTRN PRODUCT WEB LINK I INSTRUCTIONS I INFO FLOOR FINISH AND BASE FLA Polished Concrete Floor GC Finish Existing - Repair as req Gloss Dining room, restrooms, server island and other public areas NOTE: GC match all floor in Poke space with floor finish in Blue C space. FL-2 Quarry Tie Daltile OQ46 - 6"x6" Add Flash Use for sushi and liquor bar, kitchen, foodservice, BOH areas. Install wl min. 3/8' grout line. FB-2 Quarry Tile Base Daltile QCRL-1655 / 01655 - 6"x6" Arid Flash Use for all sushi and liquor bar, kitchen, foodservice, BOH areas. Install wt min. 3/8" grout line. WALL TILE WT-I Wall Tile -Kitchen MS! 412 Glazed Ceramic Gloss Beveled White htips://www.homedepotmm/p]MSI-White-Bevelled-4-in-x-l2-in-Glazed-Ceramic-Wall-Ti[-13-33-sq-ft-rase-NHDWH14Xl2BEV/206786958 WG-1 Wall Tile Grout Latinrete Tile Grout #24 Raven Sanded Seal after install WT-3 Wall Tile FOH GC Spec 6x24 - Charcoal / Black EVEN STACKED LAYOUT- Wainscot and partition walls WG-3 Wall Tile Grout FOH Laticrete Tile Grout #24 Raven Sanded Seal after install WT-4 Wall Tile FOH Mineral Tiles Aqua Pool Glass 112SI923 htts:llwww.minemltiles.wmiiridesmnt- ool lass-file-tur uoise-lx2/ WG-4 Reflective Wall Tile Grout Bostik Dimension Urethane Grout StarQuariz, StarGlass Diamond 600 htt sl/www. reenbuildin su i .com/AII-Products/Paints-Curtin s-Grouts•Grout-Sealers/Dimension-Urethane-Grout PLASTIC LAMINATE PLA Formica GC LT 3156 Grey Slate M SOLID SURFACES SSA Faux Glass Panels GC .5'Acrylic 3030 acrylic Polished Edge SS-2 Stainless Steel GC NSF 16 Gauge 30418-8 SS sushi cases, shelves, backsplash, kitchen surfaces. Custom fabricated by owners existing supplier. Countertops as Indicated SS-3 Solid Surface Countertop GC Content Everest hi polished surf. Sushi bar and liquor bar counter tops. 1.5" with .25" bullnose. SS4 HR Steel Panel GC .075" (14GA) Hot Rolled Plate ASTM A36 Use for column wrap, wall panels, toe kick and base, FOH solid door kick plates SS-5 Glass Bar Shelved GC .5" Tempered Glass Polished Edge HARDWARE H-1 Wire Grille in HR Steel Frame GC!Boe er SS Mesh in Frame Size Varies Mount atopbanquette partition walls - -h sl/www.cable-mesh.comlcablemesh/ferrule- e-cable-mesh.htmlZL H-2 Back Bar Bottle Tower GC Hot rolled steel / welded wrist. 24" deep / size varies Bolt to back bar top and ceiling H-3 Door Hardware GC Brushed Stainless - H4 Kegworks gunmetal that rail Floor Mount Use matching rail, corners, hdwr Install bracket 6" from batand. Space rail brackets every 48". DOORS D4 Spec by Architect Door finishes to match wood / staff on chairs -All doors framed satin lack (color to match 6x24 II files PAINTED SURFACES P-1 Interior Paint -Walls, Ceiling Benjamin Moore eggshell 1462 Gray Mountain Paint walls above transition strip and ceiling- customer to approve all colors prior to painting P-2 .Interior Paint - Trim Benjamin Moore eggshell 2107-40 Driftwood Paint transition strip - customer to approve all colors prior to painting P-3 Interior Paint- Walls, Soffit Benjamin Moore eggshell 981 Winds Breath Paint walls and soffits as indicated - customer to approve all colors prior to painting P-4 Interior Paint - Walls Benjamin Moore eggshell 802 San Francisco Bay Paint walls - customer to approve all colors prior to painting[ P-5 Interior Paint - Walls, Soffit Benjamin Moore eggshell 1472 Silver Chain FURNISHINGS INTERIOR F-1 Dining Side Chair Industry West Nat Metal l Brown Stride Side Chair https:/Iw .industrywest.mm/stride-side-cheirhtml F-2 Bar Stool IndustryWest Nat Metal! Brown Stride Bar Stool httpsl/www.industrywestwrn/stride-bamtool.html F-3 Dining Tables -Steel By Owner AB Finish (no grinder) Sizes Vary F4A Table Base Foldcraf 1825-30-3-15Q-BL Black Table base for 30" x 54"" tabletop. Two required per tabletop." F-4B Table Base Foldcraf 1823-30-3-15Q-BL Black Table base for 39'" x 42" tabletop. Two required per tabletop.' F-4C Table Base Foldcraf 1823-30-3-15Q-BL Black Stand up height table base for 30- x 42"" tabletop. Two required per tabletop." F4D Table Base Foldcraf 1822-42-3-15Q-BL Black Table base for 21"" x 30"" table top. " F-4E Table Base Foldcraf 182242.3.15Q-BL Black Stand up height table base for21"" x 30"" table Inc. F-5 Seat Fabric Maharam Pattern: Lariat Color: 440401406 Black https9/wwwmaharam.coMproductsliadaYmiors/006-black F-6 Backrest Fabric Knoll Textiles Pattern: Diva Color: K205112 Coal httpsaiwww.knoll.comtknolltextileproductdetaiVDiva F-7 Booth Seatng w/Accent Light JH Carr See JH Carr spec drawings F-8 Banquette Seating wl Accent Light JH Carr See JH Carr spec drawings LIGHTING L-1 Pendant Li htin -Dinin Landbrid eLi Lighting Glass Insulator Pendant - LED Blue -Green Fab with black vinyl cable L-2 Flush Mount Lighting -Ceiling Lavardin Semi Flush CeilingLight 10h x 11"dia LED Black I Copper htt s://www.wa airwmtbmwse-b -brand! d Aavardin-i-li ht-outdoor-semi-flush-mount-1 384.html? iid= L-3 Recessed Lighting - Kitchen, RR Minka Lavre Sid Rod Can / Glass Trim GT100-F 6-in EBetre Use as needed as fill -In lighting under soffits for bar / kitchten -- h lh' .li htin 'Ila.wm/min t100-fhtml L-4 Ceiling Lighting HI Bay Lighting Stusser Electric Black[ ribbed glass shade Mount all 127aff unless otherwise indicated SIGNAGElGRAPHICS SH Custom Wall Mural -1 BLUE SC - Ultra Flex FS Rated Digital Wallpaper Suede Txt Mount Interior wall - Matte fin Surface laminated - hffpJ/www.uhraffem.mm/producVwalismpes-wallmvefinqt - NOTE: Vin I wall mvedng is 100% foodservice ratedapproved SI.2 Custom Wall Mural - 2AQUA SC - Ultra Flex FS Rated Digital Wallpaper Suede Txt Mount interior wall - Matte fin Surface laminated - htt 9/w ..ultmflem.mMl roducVwalisca es-wallmvedn /- NOTE: Vin I wall covering is 100% foodservice rated t approved SO Dimensional Restroom Lettering SC Cut out.25" metal Brushed Aluminum Mount to wall above restroom vestibule S14 ADA Restroom Sign M-W OSC Curved l Tactile Braille Brushed Alum/Blk Mount 6"from strike side door frame @ 5-4"to center--htts:/Iwww.otfimsi nmm an.mm/curved-restroom-si n-ada-braille.as x R.R. PARTITIONS! DOORS PL-1 .Finish all PL-i FLOOR FINISH AND BASE FLA Polished Concrete Floor GC Finish Existing - Repair as req Gloss Dining room, restrooms, server island and other public areas WR3 Wall Tile FOH GC Spec 6x24 - Charcoal I Black EVEN STACKED LAYOUT- Wainscot and partifion walls Wall Tie Grout FOH Laticrete Tie Grout #24 Raven Sanded Seat after grout install Ceiling Paint Benjamin Moore eggshell 981 Winds Breath Paint ceiling on all restrooms- customer to approve all colors prior to painting PIE3 OUTDOOR FURNITURE Outdoor Side Chairs BFM Largo Teak/Elk https://www.webstaurantstom.mm/bfm-seating-ph101ctkbWargo-outdoor-indoor-stackable-syrithetialeak-black-amrchair/163PH101CTBL.htm1 Outdoor Bar Stools BFM Largo Teakl Elk https:[/ w .webstaurantstore.com/bfm-seating-ph102btkbWargo-outdoor-indoor-synthetic-teak-black-bar-height-side-chair/163PH1026TBL.html Outdoor Tables BFM Longport Teak/Blk httpsliw .webstaurantstore.cnm/bfm-seating-ph2424tkbiu-longport-24-square-outdoor-indoor-tabletop-with-black-frame-syntheticteaktl632424TKBLU.htm1 FE-1 Outdoor Table Base BFM Bali Bilk Sid. Ht https:flwww.webstaumntstore.mm/bfm-sealing-phtb2626bi-bali-outdoor-indoor-black-standard-height-4-leg4able-baw/163PH2626BL.html IN BSR BRAN ♦ Restaurant Design & Branded Architecture - DESIGNER.' ARCHITECT: OWNER. [ JOB NO. TSCO-100118-FW SHEET TITLE: DRAWING NO. -- BSR BRAND ENVIRONMENT 767 HAIDA PL, LA CONNER, WA 98257 206-856-7730 Ken Barnes: Ken@BSRBranding.com GLEN A. MILLER, RA CSI NCARB GA MILLER ARCHITECTURE PC LAKE OSWEGO, OREGON Ph: 503.636.7979 TRAPPERS SUSHI COMPANY / TRAPPER O'KEEFE 718 GRIFFIN AVENUE #940, ENUMCLAW WA 98022 REVISION NO. 6 INTERIOR ELEVATIONS MATERIALS AND FINISHES +�® MF 1.3 SHEET 3 OF 3 BY: KB PROJECT LOCATION: PLAN CHECK: KB/ RH . @ 2018 BSR Brand+Environment SOUTHGENTER, 468 Southcenter Mall, Tukwila, WA 98188 DATE: 01/14/19