Loading...
HomeMy WebLinkAboutPermit D19-0031 - FLYING FOODS GROUP - STORAGE RACKSFLYING FOOD GROUP 1083 ANDOVER PARK E D19-0031 Parcel No: Address: 0 �~^�xx ^�� Tukwila v~U~� v�n n ��m^w�Una Department ofCommunity Development 63OOSouthcenterBoulevard, Suite #10V Tukwila, Washington 981Mg Phnne:ZO6'431'3G7U Inspection Request Line: %O6'43B'9]5O Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049106 Permit Number: D19-0031 Project Name: FLYING FOODS GROUP Issue Date: 3/6/2019 Permit Expires On: 9/2/019 Address: Contact Person: Contractor Name: [BRE}N[ ZO41572NDAVE 5#21OC/O STO[KBR|QGECAPITAL GP, KENT'WA, 98032 12819SE385T SUITE437' RANDAL INDUSTRIES INC Address 128195E38TMPLPM8#4I7, BELLEVUE,WA, 98UD6'1395 License No: RANDA1101103 Lender: Name: |N3CODICO Address: 9725THIRD AVE NE SUITE6O2, SEA7TLE VVA'981l5 Phone: (425)373'1700 Expiration Date: 6/9/2019 DESCRIPTION OFWORK: PROVIDE ANDINSTALL RACKING WITH SHELVING AT5'AND10' Project Valuation: S25,00000 Type ofFire Protection: Sprinklers: Fire Alarm: Type ofConstruction: YB Electrical Service Provided by: TUKWILA Fees Collected: $1,031.16 Occupancy per IBC: D Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted bythe City mfTukwila, International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVAC296468: VVAState Energy Code: Public Works Activities: [hanneUzation/Stdping: Curb[ut/Access/Sidewa|k: Fire Loop Hydrant: Flood Control Zone: HaulinQ/OveobeLnad: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: O Number: O No Permit Center Authorized Signature: ~L.^J Date: I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions oflaw and ordinances governing this work will becomplied with, whether specified herein ornot. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state o,|o . 'wsreOu|adn: c,-- ^ I"northe performance ofwork. |amauthorized tosign and obtain this clevelopmen perm ,�.gd .40 to the t ditions attached to this permit. Signature: Print Name: Date75L_ /I � This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended urabandoned for aperiod ofl8Odays from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated atone extinguisher for each 1'5OOsq. ft. nfarea. Themtinguishar(s) should baofthe "All Purpose" (3A'4O8:Odry chemical type. Travel distance toany fire extinguisher must be75'orless, (|F[ 9063)(wpPA10'5�4) l: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers orbrackets shall besecurely anchored tothe mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having agross weight not exceeding 4O pounds (18 kg) shall be installed so that its top is not more than 5feet (1S24 mm) above the floor. Hand- held portable fire extinguishers having ogross weight exceeding 4Opounds (l8 kg) shall be installed so that its top isnot more than 3.5feet (1O67mm)above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (lOZ mm). <|FCg06.7 and |FC 9O6�9> 2: Extinguishers shall belocated inconspicuous locations where they will bereadily accessible and immediately available for use. These locations shall bealong normal paths oftravel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of 3: Fire extinguishers require monthly andyeadyinspectiuns. They must have atag nrlabel securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall beemptied and subjected tothe applicable recharge procedures. |fthe required monthly and yearly inspections ofthe fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (mFPA l[\ 72' 73) 5: Maintain fire extinguisher coverage throughout. 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. Nowork shall commence until afire department permit has been obtained. (City Ordinance #24J7)(|FC9V12) & Maintain fire alarm system audible/visual notification. Add ition/re location of walls or partitions may require relocation and/or addition ofaudible/visual notification devices. (City Ordinance #Z437) 9: Clearance between ignition sources, such aslight fixtures, heaters and flame -producing devices, and combustible materials shall bemaintained inanapproved manner, (|F[3O5.l) 10: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (|FC3lS3l) ll: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall bemaintained. 6: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #Z437) 12: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval nfsuch condition orviolation. 13: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau nt(2U6)575'44O7. 14: 'BUILDING PERMIT U]ND[OONS*~~ 15: Work shall beinstalled inaccordance withtheapprovedconstr cbondocunnents,andanychangesmade during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. lG: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 17: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. l&: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage ofstorage racks 8feet orgreater inheight. 19: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 20: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 21; VALIDITY OFPERMIT: The issuance orgranting ofapermit shall not bpconstrued tobeapermit for, cvan approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. ZZ: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports tothe Building Official in vtimely manner. 23: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall besubmitted tothe Building Official. The final inspection report shall beprepared bythe approved special inspection agency and shall bosubmitted 1nthe Building Official phnrtoondasa condition offinal inspection approval. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438'9350 1700 BU|LD|NGF|NAL** 1400 FIRE FINAL 4046 Q-EPUXY/EXPCON[ CITY OF TUK Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Perf No. 1411- 00 3 Project No. >2--f ice use onl Date Application Accepted: Date Application Expires: For o CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Arkic3,/-zie.„ Site Address: toe Tenant Name: "ra-t-O .-Fct.715 ElVW-7; • PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Na • Addrel -3 tcl 9.5e2._ .....1 . 431 C" • Statt:,..upy ZiF930c4 Phortz. , 315 . rio.c6 Email (, e GENERAL C NTRACTOR INFORMATION Company Na lurNAZIL— \ Add C Si 'I 4i ciWz_W StatZi Phon4as . .9.sFax/5 CiWY KI\II&A L... , II 0 p Date:0 )1 ci Tukwila Business License No.: King Co Assessor's Tax No.: Z Suite Number: Floor: C2re... New Tenant: Yes El No ARCHITECT OF RECO 'RD( Company NatneNtrE,j4 l' iSSQ Architect Name: Addrescr5s _ Ik.t-11A .(dILW.. Ci tat • ‘CZALLA-ts S8Z1.". Ph o . •••• ' . EmaiL4 e,44-‘j ENGINEEROF RECORD 1 E. • Co . EngineerName keki k. (34 JC*P--1 " Addre a k.....v...), sz,ock ,...-/... a:4 Cit&fri.A.W1/4tA— State: CA_ zilf 0:4 MIN% EmaRockuc t,r).1ccJfl 1 LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name.' leNit LO 661. C-0 AdC1,54-ZS. • 5n 'ker_, M. e5T6 (cue- Cityj. stateLpr zip:5ai is KlApplications \Fonns-Apptications On Line \ 2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 1 of 4 BUILDING PERMIT INFORMATI 206-43 670 Valuation of Project (contractor's bid price): $ oze :1:\e_se.. Existing Building Valuation: $ Descri e the scope of work (please ovide detfiled information): 1 000 vi&._- k IN—rv9t-L-- -- /IOC 1 PO k^)t LAI 1 Nor-r §.. ( lit 1 0 1 Will there be new rack storage? J .... Yes LJ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 2"4 Floor rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers El Automatic Fire Alarm None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? CI Yes El No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 1 HAApplications\Forrns-Applications On Line\2012 A plicationsWerrnit Application Revised - 2-7-12.doca Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature. Print Nam . Mailing Address: ZED AGENT: t-752)ci ab-ig Date: I /24 /, C17 Day Telephon . ‘1(bc.? vur (AA-Cacc7 City State Zip H:kApplicationstFonnt-Applications On Line12012 Applications1Permn Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 PUBLIC WORKS PERMITIINF YIATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District o Tukwila El .. • Water Availability Provided Sewer District O .. Tukwila .. • Sewer Use Certificate .Water District #125 0 ...Valley View 0 ...Sewer Availability Provided 0...Highiine 0... Renton 0...Renton 0... Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): .. • Civil Plans (Maximum Paper Size — 22" x 34") O .. Technical Information Report (Storm Drainage) .. Bond 0... Insurance Easement(s) Proposed Activities (mark boxes that apply): .. • Right-of-way Use - Nonprofit for less than 72 hours .. Right-of-way Use - No Disturbance .. Construction/Excavation/Fill - Right-of-way 1:1 Non Right-of-way 0 o .. Total Cut cubic yards .. • Total Fill cubic yards O .. Sanitary Side Sewer o .. Cap or Remove Utilities o .. Frontage Improvements o .. Traffic Control O Backflow Prevention - Fire Protection 0...Geotechnical Report 0... Maintenance Agreement(s) o .. Traffic Impact Analysis 0.. Hold Harmless — (SAO) 0.. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0... Work in Flood Zone Ej ... Storm Drainage 0... Abandon Septic Tank 0...Curb Cut El...Pavement Cut O... Looped Fire Line Irrigation Domestic Water !I 0...Grease Interceptor ... Channel i zation 0...Trench Excavation 0... Utility Undergrounding O .. Permanent Water Meter Size (I) " WO # (2) " WO # (3) " WO # 0 .. Temporary Water Meter Size (1) " WO # (2) " WO # (3) " WO # 0 .. Water Only Meter Size " 1 WO # 0 .. Deduct Water Meter Size 7, 0 .. Sewer Main Extension Public 0 Private 0 O .. Water Main Extension Public El Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0.. Water 0 .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip HAApplications\Forrns-Applications On Line \2012 ApplicationsWermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $646.45 D19-0031 Address: 1083 ANDOVER PARK E Apn: 2623049106 $646.45 DEVELOPMENT $616.86 PERMIT FEE R000.322.100.00.00 0.00 $591.86 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $25.00 TECHNOLOGY FEE $29.59 TECHNOLOGY FEE R000.322.900.04.00 0.00 $29.59 TOTAL FEES PAID BY RECEIPT: R17094 $646.45 Date Paid: Wednesday, March 06, 2019 Paid By: RANDAL INDUSTRIES INC Pay Method: CHECK 12518 Printed: Wednesday, March 06, 2019 1:14 PM 1 of 1 SYSTEMS Cash Registe Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $384.71 D19-0031 Address: 1083 ANDOVER PARK E Apn: 2623049106 $384.71 DEVELOPMENT PLAN CHECK FEE 84.71 R000,345.830.00.00 0.00 $384.71 TOTAL FEES PAID BY RECEIPT: R16582. $384.71 Date Paid: Tuesday, January 22, 2019 Paid By: RANDAL INDUSTRIES INC Pay Method: CHECK 12498 Printed: Tuesday, January 22, 2019 2:20 PM 1 of 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 670 Permit Inspection Request Line (206) 438-9350 Project: 417f3'S Type of nspe on: iiii.44&e./4 et.r Address: 0 fYlic--V6 4744, 'Date ic Called: ,Speciaac ons: 'Date Wanted: p.m. 'Requester: Phone N : Approved per applicable codes. 1 1 Corrections required prior to approval. OMMENTS: n pecto : Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. w INSPECTION RECORD Retain a copy with permit J?/%? 80 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43'i'-3670 Permit Inspection Request Line (206) 438-9350 Project, L.m 'rr Type of Inspection: z �' /. Address. Date Called: 7 Special Instructions: Date Wanted: Requester: Phone No: proved per applicable codes. Corrections required prior to approval. 0MMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd.. Suite 100. Call to schedute reinspection. March 21, 2019 OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118-3216 USA Tel: (206) 725.4600 • Toil Free: (888) OTTO-4-US • Fax: (206) 723-2221 ' WBE W2F5913684 + VUABO Registered Agency • 1Website: www.ottorosenau.com FINAL REPORT City of Tukwila 8uildingDepartment 6300 Southcenter Blvd, Suite,100 Tukwila, Washington 98188-2544 Project: Flying Food Group Tukwila TI Permit Number: D19-0031 Address: 1083 Andover Park East, Tukwila Job Number: 19-0156 We state that the work requiring special inspection was, tc the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge is limited to our reports. All typewritten reports have been mailed toyour office or are enclosed: Ail reports appear to be complete. report should not be considered as a warranty for conditions and/or details of the building; s inspected are: L Proprietary anchors mechanical Sincerely, OTTO ROSENAU & ASSOCIATES, INC. Susan Rosenau-Mos Vice President Etrtail i : Randy Barger - Randal Indust By G. GHANIAN DATE 1 - 1 6 - 1 9 SUBJECT RAdK DEOI4N & ENOINEERINd do. 412 WEST BROADWAY, BUTTE #204 OLENDALE, dA. 91204 TEL(818)240-3E110 rackdeaigni@gmail.com SHEET NO. 1 JOB NO. JR19727 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: RANDAL INDUSTRIES 1 083 ANDOVER PARK EAST TUKWILA, WA 981 88 PER IBC 201 5 SEC. 2209.1 ASCE 7-1 0 SEC. 1 5.5.3 RMI/ANSI/MH 1 6.1 :201 2 STORAGE RACKS CAPACITY: 2500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD-19727 EXPIRES 12-26-19 FRra"E CODE COMPLIANCE APPROVED MAR 0 4 2019 City of Tukwila BUILDING DIVISION 031 FILE RECEIVED CITY OF TUKWILA JAN 22 2019 PERMIT CENTER G. By GOHAN|AN 1 1G 1Q DATE — — SUBJECT RACK DE014N & ENOINEERINO 00. 412 WEOT BROADWAY, OUDTE #204 dA. 91204 ` TEL:(810)240-3010 k6*rx. SHEET NO. 2 RD 18727 BEAM DESIGN � � � SEISMIC D[5|CN Y= Scm «| xVV Rxl.4 FRONT VIEW S0[ VIEW LOAD PER BEAM + 25% IMPACT LOAD (2.5«x.88)+(1.2xx.25) = 2.5= 1.3K Z BEAMS *i� W= =1h 'K O S = 49�8J n� � 5xwL^ ^ L �= — 57^ JD4JxI — —' 27 ��78o—' IBC 2015 SEC. 2209.1 A3CE 7-10 SEC. 15.5], RM|/ANS|/WH 16.1:2012 3 =O9§ (U�0� YY[B 5|T[ "SITE CLASS D^) co � ` ' ' 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED 2 VV=D.. L + PRODUCT LOAD T LDx0 PER C0L.= 2»2.5« —2.5« 2 COL. P=.2o.+ (2.5«0J5)=2.1« YV=2u+ (2.5^"0.57)=1.9 " Y = 21K mw:x. \L—=� .32« /x^n^. LONG|T. SEISMIC 6.2"K By G. OHAN|AN 1 1G 1g OAT�-���'_—_. SUBJE[T.-'----'_ � �� �1� �I�� �� ���u� =���wun .� =m�vu�nmm��nx� m~. 412 WEOT BROADWAY, PUITE #2Q4 TEL:(818)240-~3810 E-MAIL: rackdelgignt �gmmail.mom SHEET NO J RD JOB NO.. 19727 - COLUMN DESIGN F'=55ms Ao=.54 |x=.67 Se=.4 r,=l.l ry =0.5 COMBINED STRESS RATIO z n E |x Pex= ' =54U /KL\z � `' ox=/-CcP=.g} Pex Oc=1.8 Ou=1.67 Cmx=.85 BASE PLATE ANCH. TENSION .2« ANCHOR SHEAR =J1« KL 5Oxl � = � =54 rx 1.1 KL �§ - -58 y o.o Mn=Ie*F.=24 Fe= 7T zxE = DO X =~� /-- = O 80 (KL)z c `�y''` � ` ry / \ z Fn=Fy[65O " )=42 «o cx1 .5 Oc�P O���x� + � = 55< 1 Pn Wn,ux ' (2)-1/2^0 ANCHORS PER BASE PL., J 1/4^ EM8. S|MPSUN STRONG BOLT 2 ESR-3037 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.07x1x65=2j« .8^x.125^ PRONG A = .1 Fy50mn Po =.lx5Ox.42« Ma = 2 «x5^ = lO ^n COW BEARING CAPACITY OF COL. HOLE M =.Olxw|z_ lJ^« cwo M = 52 ~« M =0.5 ^« SEISMIC TOTAL PRONG C0NN. 5.2"" 2J w 6.2 ^« | 52'K By__ G...OH4N|.AN__ 1 16 19 DATE. - - SUBJECT ����� �� �� D�1� ���� CO.�^="^ "^"^'��==^� =° ^^^"�v^��u����°^m^� v~~, �� 412 ,,mm�n�^ BROALIWAY, p6 urrE #204 TEL:(818)240-3810 E—MAIL: rackdepigntOgmail.com SHEET No. JOB NCL RD-19727 OVERTURNING M �'32«x2 ,138^xO.56=59`« MOT COL, Wn = 2.1Kx44^=81^« NO UPLIFT LOAD TO DIAGONAL P =.32«x2 x 60 =.O « COL- 42 F'=55ma Ao=.4l r,=.45 L= hO^ po = 2.5« CHECK WELDS Pn=LiFu=.OSxl^x55 =I9^ o=2J5 3.9 ^ =l.65x2 =I}« 235 smc CHECK SLAB 2100 o` =21 1OUO � / , `3O2=17" 2.1x144=302o" W= /4.5`z ' 10ODx�—x12=D55^# \ 12 /2 � l2x6 3= =72 G 855 ~/ = "12�1 § 2500=80 72 � z./« z./« BOTH SIDES TYP _ TOP LEVEL LOADING YY=O.2m+1.J,=1.5« LOAD PER COL, v=25« MOT =.25«x2 xl20^=§U^« Nn = 1.5«x44^=64 ^« NO UPLIFT i TYP 1 21O0# 6^ CONCRETE SLAB 2500 PSI. CONC. 1000 P3F. SOIL ARCHERI CONSTRUCTION, INC Flying Food Group 1083 Andover Park East Tukwila, WA 98188 ATT: Randy Barger RE: rack storage in existing warehouse Dear Mr. Barger, 7855 S. 206th Street • Kent, WA 98032 253.872.7222 • Fax 253.872.7277 ARCHEI-219•DR FILE Date: 1/17/2019 You are proposing to install new racking within the warehouse space. The racking will have storage to approximately twelve feet above the finished floor. Your storage commodity consists of cartoned paper goods, cartoned plastic cups, cartoned food snacks packaged in foil and bottled water and all are non - encapsulated. Per NFPA 13 this is categorized as miscellaneous storage and a Class IV Commodity. The existing fire sprinkler system at the roof consists of a wet system with Large orifice sprinklers of standard temperature range. The system is hydraulically designed to a WSRB design density of .39/5,600. Per NFPA 13, chapter 13, table 13.2.1 a Class IV commodity stored to twelve feet, non -encapsulated, eight - foot aisles, without in -rack sprinklers requires a sprinkler design of Extra Hazard 1. The existing fire sprinkler design of .39/5,600 is above the current NFPA requirement for this type and arrangement of storage. No further sprinkler modifications are required at this time. Should there be a need to change the type or arrangement of storage in the future please feel free to give us a call. Thank You, Archer Construction Rix-lc/Val/yard/ Rick Villyard Fire Sprinkler Division ------ REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 4 2019 City of Tukwila BUILDING DIVISION rick@archerconstruction.com ‚9,-oo3' UTILITIES -FIRE PROTECTION RECEIVED CITY OF TUKW LA JAN 22 2019 PERMIT CENTER City of Tukwila Department of Community Development February 27, 2019 RANDAL BARGER 12819 SE 38 ST - SUITE 437 BELLEVUE, WA 98006 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D19-0031 FLYING FOODS GROUP - 1083 ANDOVER PARK E Dear RANDAL BARGER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 1 1x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Please note, is a duplicate of the building permit ** D19-0014 review. I had the discussion at the permit counter with Mr. Barger where I proposed possibly turning the racks to a different configuration to resolve the issues listed below as the current layout proposed will not be acceptable to meet codes for life safety requirements. ** The layout for the storage racks as shown shall require an alternate layout. Aisles shown create dead-end corridors that exceed 50 feet (sprinkled building). Exiting the warehouse through the electrical room shall not be allowed. Both exits out of the electric room shall provide exiting from that room to an exit path leading to exit discharge. A swinging egress door shall be required leading out of each fenced storage rack space. Doors in any position shall not reduce the required width of the means of egress by more than one-half or 7 inches fully opened. Revise the rack layout to show compliance with egress from those areas. (IBC 1005.7.1, 1020.4#1, 1010.1.10.3- WSA) Note: Contingent on response to these corrections, further plan review may request for additional corrections. 63nn .4nutheenter Rnulevard Suite # 100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or -by a messenger -service. Jazzel Salzar Permit Technician File No. D19-0031 PERMIT C C g7: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0031 DATE: 2/28/19 PROJECT NAME: FLYING FOOD GROUP SITE ADDRESS: 1083 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: 1\110 12\iick Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator MI PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 3/05/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions -Denied (ie: Zoning Issues DUE DATE: 4/02/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg PlngLJ PWLJ Staff Initials: 12/18/2013 PERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0031 DATE: 01/22/19 PROJECT NAME: FLYING FOODS GROUP SITE ADDRESS: 1083 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT Co Building Division Public Works e Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/24/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews (ie: Zoning Issues Approved with Conditions DUE DATE: 02/21/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire E Ping 0 PW Staff in itials:\tc 12/18/2013 Contact Person. Summary of Revision: C-14A-r74/- 012.7',21-7-7C4) otizo 2x77- 6617 Date: ICI City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: 1:47-s Li Response to Incomplete Letter # Response to Correction Letter # Lil Revision # after Permit is Issued `42,1••=1.... E Revision requested by a City Building Inspector or Plans Examiner El Deferred Submittal # Project Name: IFE-4. I r•V C-) Project Address:_i oF3 Atr,Akrr-h_ Phone Number: 41.-Sr- "3-q RECEIVED CITY OF TUKWILA FEB 28 NV PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including te of revisio Received at the City of Tukwila Permit Center by: 6V1j7Le ccwor JJj Entered in TRAKiT on f5 WAPermit CenteATemplates1Forms5Revon Submittal Fderadoc Revised: August 2015 RANDAL INDUSTRIES INC c Home Kspanol Connect Search L.&I Page 1 of 2 Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-Z 1 nilox .&1 UVorkplace Rights Traders & Licensing RANDAL INDUSTRIES INC Owner or tradesperson Principals BARGER, C RANDAL Doing business as RANDAL INDUSTRIES INC WA UBI No. 601 939 344 12819 SE 38TH PMB #437 BELLEVUE, WA 98006-1395 425-373-1700 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. RA N DAII011 O3 Effective — expiration 09/23/1999— 06/09/2019 Bond DEVELOPERS SURETY & INDEM CO Bond -account no. 855470C Active. Meets current requirements. $12,000.00 Received by L&I Effective date 05/29/2002 05/29/2002 Expiration date Until Canceled Insurance American Fire & Casualty Co Policy no, BKA54102720 $1,000,000.00 Received by L&I Effective date 05/10/2018 06/09/2017 Expiration date 06/09/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. I - 71 ----_r)T TTIT—LA1 n')(1') AA 0.T Tr'—T) ANTT\ A TT el 1 (1/ Dr(' A \I7— Help us improve 1/i/1n1n VdZITTEN DIMENSIONS ON THI5 DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSION5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITION5, ETC. FERTAININS TO THE NlORK BEFORE FROCEEDINS. h OWNER MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND/OR CONDITIONS SHONE! ON TNESE D lNG5. ANY SUCH VARIATION SNALL BE RESOLVED 5Y THE OV R PRIOR TO PROCEEDING WITH THE.WORK, OR THE CONTRACTOR SNALL ACCEPT RAL RESPONSIEILITY FOR THE COST TO RECTIFY SAME. VICINITY MAID NOT TO SCALE x� mm AS-SU I LT PLAN � SEE GENERAL NOTES SCALE: I/8° = ('-0" F I I (N ANDOVER EA5T 9 ANDOVER EA5 w 5USINE 55 Ef, EN ER U5INE55 GENT RBUI w a 171NG B 5UILiDIN6 A ( �vpoosF Q tV K y �p � lz Id o m z I O o p "NOTE. ALL @%ISTING PARKING, ACCE83, SBiVICi L- AREAS, AND LANDSCAPING TO R@MM 410.011 I 588° 12' 31" E SITE PLAN NOT TO SCALE r" 1RE61 ��������....444 A GT coo v U ¢o o O 4- O ct k o tL Q data: 1-I I -la permit: revisions: drawn by:KLM checked by: GN G? � WRITTEN DIMENSIONS ON THIS ORAMM SHALL HAYS PRECEDENCE OVER SCALED DIME115ION5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. PERTAINING TO THE WORK BEFORE PRIXEEDIN6. THE OWNER Mx'T BE NOTIFIED OF ANY VARIATION5 FROM THE DIMENSIONS AND/OR CONDITON5 5HOWN ON THCSE DRA"N65, ANY SOH VARIATION SHALL 8E RESOLVED BY THE OI'AER PRIOR TO PROCEEDING WITH THE WORK, OR THE CONTRACTOR SHALL ACCEPT FIILt. RESPONSIBILITY FOR T COST TO RECTIFY SAME. - 52'-0° 14 w e ELECTRICAL w (I ROOM W w < EXIST' 6 U, W W W W W W L W W W W W W W W W W W W W W W W W W W W W W W W W CORRECTION FLOOR PLAN - OPTION B L TR# (D OCCUPANCY LOAD: SEE GENERAL NOTES SCALE I/6" - 1'-0" _ AREA, 50. FOOTAGE LOAD: "'NOTE: 3-COMPARTMENT SINK TO BE USED MINIMALLY OFFICE AREAS, 2,110 50, FT 21 - - AND WILL ONLY BE USED TO GLEAN OUT ORIGINAL OFFICEM"OA AREA. 2,500 SO. FT 21 PACKIN6 ITEMS. NO. SERVICE WARE SOILED WITH FOOD PRODUCT WILL BE PROCESSED AT THIS PROPERY. DOOR SCHEDULE, RECEIVED DOOR NUMBER TYPE WIDTH HEIGHT THICKNESS DR MATERIAL DR. FINISH FRAME MAT. FRAME FINISH FRAME RATING HARDWARE INTERIOR 3'-0" 'V-O" 1-3/4" HOLLOW METAL - - HOLLOW METAL - - qO MIN. (3) 4-1/2" x 4-1/2" 26D HIN6E ) HANDLE;, PA55AGE LON OGKSET LE PDO 5P126-626 PHL 2-3/4" (1) WALL STOP; 260 CITY OF TUKWILA FEB 2 8 2019 �R PERMIT CENTER �913 RE61 � A GT d H � x � V to tID A- �0- K OO}� o "K LL H Q data: I-31-1a pormit: reI,vislons: 1-30-Iq QS 2-15-iq drawn by KLM choakocT by: GN aI= CODE COMPLIANCE APPROVED MAR 042019 City of Tukwila BUILDING DIVISION WRITT@! DIMEN510N5INd THIS pRAWING SHALL HAYS. PRECEDENCE OVER SCALED DIF�NSIONS. LONTRAOTOR SHALL VERIFY ALL DIMENSIONS. CONDITIONS, ET V PERTAINING TO THE WORK V1F 1 PROf,EEDING. THE OWNER NUST BE NOTIFIED OF ANY YARIATIGNS PROM THE DIMENSIONS AND/OR CONDITIONS SHOYffI ON THESE DRAWINGS. ANY SUCH VARIATION SHALL BE RESOLVED BY TIE: OYAIER PRIOR i0 PROCEEOIN6 WITH THE WORK OR THE CONTRACTOR SHALL ACCEPT FULL RESPONSIBILitt FOR THE CABT TO RECTIFY SAME EXI5TING 31t" - 25 GA. INSULATION. EXI5TING 21y" TRACK 6 STUDS 24" oz. - 5TUD5 CUT DURING 2W - 25 6A6UE BRACE PREVIOUS T.I. ® 5'-O" o4' ALTERNATING DIRECTIONS TO STRUCTURE ABV. - AGGOUSTIG CEILING TILE AGGOUSTIG GEILIN6 TILE NEW 21t" - 25 &A. 5ND5 ® 24" o.c.. 31t!" - 25 6A6UE SUDS d TRACK w/ ig 6WB (2) SIDES. NEW STUDS 24" o.G. w/ (1) LAYER fig" &N5 EA. 515TEPZP TO EXISTING 51105 AND SIDE w/ FIBERGLASS IN'51LATION 5GREWED TO EXI5TN6 TRACK w/ FIBER61-A55 INSULATION. _4 4 6 EA5E PER CONTRACTOR 5A5E PER GONTRAGTOR EXISTING FINI FLOOR FLOORING PER CONTRACTOR EXISTING rINIS 4 FLOOR r FLOORING PER CONTRACTOR r=EXISTING GbNGRtTE FLOOR 5LA8,,a" EXISTING GONGRETE FLOOR SLAB. Ti PICAL NON—LOAI:) BEARING TYPICAL NON—LOAl;) BEARING PARTION IDETAIL PARTION i:�ETAIL SEE 6ENERAL NOTES 50ALE� 1-1/2..= I'-0" SEE GENERAL NOTES SCALE: 1-1/2" - 1'-0" 30'-O" z xNx W 1F V LNi PIN = 4"xe"x%" PLATE w/ (2) 116"0 HOLES; 14" LONG ' ( 2"4> 5GH40 PIN d (2) Vz"x3" LAG -BOLTS u 4 Q 21y" 4 5014 40 PIPE FENCE POST BA5E = 8'x8"x�&" PLATE w/ (4) ` '1, HOLES; 6 (4) ly"x444" STRONG BOLTS w/ WEDGE ANGHOR5 4 EXISTING CONCRETE FLOOR SLAB 21ts" - 25 GA. STUDS 0 24" o.o. w/ (1) LAYER %" GWB EACH 51DE w/ INSULATION. 6WB TO OVERLAP JOINT FIRE CAULK ANY PENETRATION5 FIRE ALARM/CONDUIT EXISTING 2L!" TRACK 6 STUDS a 24" o.c. - STUDS CUT DURING PREVIOUS T.I. ACCOU5TIO GEILIN6 TILE �8" 6WB TO 9'-4" AFF T fib" GWB TO 10'-0" AFF OEEIGE WNAREHOUSE BASE PER CONTRACTOR EXISTING FIN" FLOOR FLOORING PER CONTRACTOR �EXISTIN6 CONCRETE FLOOR SLAB, < TYPICAL 410 MIN. RATEC> PARTION PETAIL ASSEMBLY SEE 6ENERAL NOTES SCALE: 1-1/2" a 1'-0" EXIS . RO { TRU SE5 EX15TIf BEAM — - -- —11/2'0 5CH40 5EE D AIL D/A4 TOP RAIL; 5ET IN 2" APPX.4" BELO W BOTTOM OF EXI5TI ROOF TRU55E5 2%2" (P SGH40 PIPE COLUMN, TYP. \ U \ \ i'O" x 10'0\ \ CHAIN LINK GATE tY IS) tY 3'0-�iC7'0" M/AN DR. / EXIT HARDWA 5TRON HINC�E PENCE POST TO EXISTING EXIT $ 6ATE ELEVATION QSTRUCTURE I7ETA I L O STRUCTURE I;)ETA I L SEE GENERAL NOTES BGALE, 1-1/2'- 110" SEE GENERAL NOTES SCALE: 4g" m 1'-O" 6 C6LU-LAM ssis w.Esi � t�`Te or rvn��N�e*a7 con U $o W 3 `J z B � s ``^^ `ul uD BI.Y n z �m L u- SL _ data: I-BI-Ia pormit: rovislons: 1-30-19 OA 2-15-19 drawn by KLM ahoakod by: GN T +Hi=E=-T 03= ® CO%IA ERECEIVED LEDCOU CITY OFTUKWILA FEB 2 8 2019 N PERMIT CENTER 1� BOTH SIDES TYP. / I I SAFETY LOCK fyP• � a 1 " TYP 2/a3" - I I c 16 gpLApER l4d 30 2 (� �) -- -- I (A' Rp� 0 J, A 2 3/4" O � � O Et= ( SEC. A -A I "� � I 0 Pod r: TY 'fie 1 TY s 1/2" °g — / I M o (2)-1/2"'0 ANCHOR BOLTS PER BASE PLATE _ 0 3 1/4" EMB., (SEE NOTE NO. 4) SEC. B-B I m obi' 3 BASE PLATE DETAIL 1 BRACING DETAIL 2 2 PRONG CONNECTION 3 ROW SPACER q. NOTES: 1-DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE IBC 2015, ASCE/SET 7-10, ACI 318-14, RMI/ANSI MH 16.1:2012 2-STEEL FOR ALL SHAPES FY=55 KSL ASTM A1011 GR.55 (EXCEPT AS NOTED) 3-NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN A SHOP OF AN APPROVED FABRICATOR NO. (E70XX ELECTRODES) 4-ALL ANCHORS SIMPSON STRONG BOLT 2 ESR-3037 SPECIAL INSPECTION IS REQUIRED 5-CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 102" _ 44 44" 44" 6—STORAGE INSTALLATIONS S A ALCAPACITY: 7-RAHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT RACK SIGN OF 0SQLEVE) RE INCHES IN AREA, SHOWING THE CAPACITY OF 8-STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10'-0" OF HEIGHT 3 9-THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 10-STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS ONLY RkEVIEtAJED FOR 2 2 CODE COMPLIANCE RECEIVED APPROVE® CITY OF TtiKWILA A MAR 04 2019 JAN 22 2019 PERMIT CENTER o City of Tukwila BUILDING DIVISION oP °NRAC IENGINEERING 412 WEST BROADWAY SUITE #204 GLENDALE CA. 91204 y r SCALE: NONE DRAWN BY:.A.4.v DATE: 1-15-19 P PROJECr: RANDAL INDUSTRIES p Fcrsrea ���" 1083 ANDOVER PARK EAST, TUKWILA, WA 98188 FRONT VIEW SIDE VIEW SS'°NAL ��° STORAGE RACK DETAILS JEE N0. RD—OBN0. SH19727 EXPIRES 12-26-19