Loading...
HomeMy WebLinkAboutPermit D19-0056 - CITY OF TUKWILA / JUSTICE CENTER 1 - DEMOLITION OF ABOVE GRADE PORTIONS OF FOUNDATION (VACANT LOT)CITY OF TUKWILA (JC-1) 3415 S 150TH ST D19-0056 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaVVA.gov DEVELOPMENT PERMIT 0041000515 Permit Number: D19-0056 3415 S 150TH ST Project Name: CITY OF TUKWILA (JC-1) JUSTICE CENTER 1 Issue Date: 3/18/2019 Permit Expires On: 9/14/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: BANWAIT SUKHCHAIN 21639 104TH PL SE , KENT, WA, 98031 ETHAN BERNAU 101 YESLER WAY - SUITE 606 , SEATTLE, WA, 98104 BNBUILDERS INC Address: 2601 4TH AVE SUITE 350, SEATTLE, WA, 98121 License No: BNBUII*990K3 Lender: Name: Address: Phone: (206) 838-37-05 Phone: (206) 382-3443 Expiration Date: 9/15/2019 DESCRIPTION OF WORK: DEMOLITION OF ABOVE GRADE PORTIONS OF EXISTING FOUNDATION. BUILDING HAZARDOUS MATERIALS ABATEMENT NOT APPLICABLE. CONTRACTOR WILL CUT AND CAP SEWER LINE. SITE DEMOLITION INCULDING SUBGRADE FOUNDATIOS ARE PART OF PW18-0171 AND EXCLUDED FROM THIS PERMIT. PUBLIC WORKS FEES PAID UNDER PW18-0171. WATER DISTRICT 125 & VALLEY VIEW SEWER DISTRICT. Project Valuation: $14,400.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $691.33 Occupancy per IBC: Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: [hunne|izahon/Striping: Curb[ut/Aceo/5idewa|k: Fire Loop Hydrant: Flood Control Zone: Haul inQ/OversbeLoad: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signa Volumes: Cut: 0 Fill: O Number: O Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and oTclinances governing this work will be complied with, whether specified herein or not. The granting ofthis permit does not presume togive authority mviolate orcancel the provisions ofany other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and agree tothe conditions attached tothis permit. .� Signature: Date: _» Print Name: f����� �� 41 L* This permit shall become null and void ifthe work isnot commenced within l8Odays for the date ofissuance, orif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT COND0ONS' 2: All permits, inspection record card and approved construction documents shall be kept a*the site of work and shall be open to inspection by the Building Inspector vnd| final inspection approval is granted. 3: Remove all derr%olition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based nnsatisfactory completion ofthis requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Bui|din8Department (ZO6'4]1,3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. Ei VALIDITY OFPERMIT: The issuance orgranting ofapermit shall not beconstrued tnbeapermit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction uferrors in the construction documents and other data. 7: 'PUBLIC WORKS PERMIT CONDITIONS' 8: Schedule and attend aPreonstr cdon[NeednQwiththePublicVVodoDepertnentpriortogartofwor under this permit. Toschedule, call Public Works at(2O6)438'935O. 9: The applicant or contractor must notify the Public Works Inspector at (206) 433-0179 upon commencement and completion ofwork atleast 24hours inadvance. All inspection requests for utility work must also be made 34hours inadvance. 10: Prior to construction, all utilities |nthe vicinity shall be field located. NOTE: For City of' Tukwila utility locates, call 81lor1'8O04l4'5555. 11: Permit is valid between the weekday hours of 7:00 a.m. and 10:00 p.m. only. Coordinate with the Public Works Inspector for any work after 5:UOp.m.and weekends. 12: Any material spilled onto any street shall becleaned upimmediately. 13: Temporary erosion control measures shall beimplemented asthe first order mfbusiness toprevent sedimentation off -site orinto existing drainage facilities. 14: The site shall have permanent erosion control measures inplace as soon aspossible after final grading has ~ been completed and prior tothe Final Inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438-9350 1700 BU|L0NGF|NAL** 5200 EROSION MEASURES 5210 EROSION MEASURES FNL 0101 PRE -CONSTRUCTION 1600 PUBLIC WORKS FINAL 5160 PUBLIC WORKS PRE -CON CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: ik Date Application Expires: (For office us only) I CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION tgoi-t, 91— Site Address: Vacant Lot on South Side of 150th (JC-1) King Co Assessor's Tax No.: Suite Number: New Tenant: Tenant Name: N/A 004100-0515 PROPERTY OWNER Name: City of Tukwila Address: 6300 Southcenter Blvd City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Ethan Bernau, SOJ (Owner's PM) Address: 101 Yesler Way, Suite 606 City: Seattle State: WA Zip: 98104 Phone: (206) 838-3705 Fax: Email: ethanb@sojsea.com GENERAL CONTRACTOR INFORMATION — Company Name: BNBuilders Address: 2601 4th Ave, Suite 350 City: Seattle State: WA Zip: 98121 Phone: (206) 382-3443 Fax: Contr Reg No.: BNBUII*990K3 Exp Date: 09/15/2019 Tukwila Business License No.: BUS-0992476 HAApplicationsWorrns-Applications On Line \201 1 Applications1Perrnit Application Revised - 8-9-11.docx Revised: Augurs 2011 bh Floor: E] Yes D ..No ARCHITECT OF RECORD Company Name: DLR Group Architect Name: Erica Loynd Address: 51 University Street, Suite 600 City: Seattle State: WA Zip: 98104 Phone: (206) 461-6000 Fax: Email: eloynd@dlrgroup.com ENGINEER OF RECORD Company Name: KPFF Engineer Name: Marty Chase Address: 1601 5th Ave, Suite 1600 City: Seattle State: WA Zip: 98101 Phone: (206) 622-5822 Fax: Email: marty.chase@kpf . - n LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A Address: City: State: Zip: Page I of 4 BUILDING PERMIT INFORMATION — 206-431-3670 14,400 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Demolition of above grade portions of existing foundation. Building hazardous materials abatement not applicable. Contractor will cut and cap sewer line. Site demolition including subgrade foundations are part of Permit PW18-071 and are excluded from this permit. Will there be new rack storage? El Yes El.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC r Floor 0 '21 Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ..... No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0. . Automatic Fire Alarm 21 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 1=1.._.... Yes Z1 ...„..No If "yes', attach list of materials and storage locations on a separate 8-1/2" x I I "paper including quantities and Material Safety Data Sheets, SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications \ Fossils -Applications On Line \ 2011 Applications\ Permit Application Revised - I olocx Revised: August 201 Page 2 of 4 bh PUBLIC WORKS PERMIT INFORMATION — 2(16-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ...Tukwila ..,VVater District #I25 0 ...Water Availability Provided Sewer District 0 ...Tukwila D ...Sewer Use Certificate 0 Highline 121...Valley View 0 .. Renton .. Sewer Availability Provided El Renton 0 .. Seattle Septic System: 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark hoxes which applv): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) 0 .„Bond Insurance 0 Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance O ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way E O . Total Cut 0 ...Total Fill cubic yards cubic yards .. Geotechnical Report _ Maintenance Agreement(s) 0...Traffic Impact Analysis 0...Hold Harmless — (SAO) 0 „.Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance .. Work in Flood Zone D .. Storm Drainage 0 ...Sanitary Side Sewer .. Abandon Septic Tank 0 .. Grease Interceptor ill ...Cap or Remove Utilities 0., Curb Cut 0 Channelization 0 ...Frontage Improvements 0 .. Pavement Cut 0 .. Trench Excavation El ...Traffic Contro 0.. Looped Fire Line _ Utility Undergrounding ...Backfiow Prevention - Fire Protection Irrigation Domestic Water 0 ...Permanent Water Meter Size... WO # )1 D ...Temporary Water Meter Size WO # 0 ...Water Only Meter Size /1 WO # ...Deduct Water Meter Size 0 ...Sewer Main Extension Public 0 Private 0 0 ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ,„Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip HAApplicationsWorms-Applicallions On Line\201 1 Applical ions \ Permit Application Revised - 8-9- II .clocx Revised; August 201 bh Page 3 of 4 c PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, The Building Official may grant one or more extensions of lime for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Ethan Bemau Date: 02/08/2019 Day Telephone: (206) 838-3705 Mailing Address: SOJ, 101 Yesler Way, Suite 606 Seattle WA 98104 City State Zip lb: Applications Form, Applications On Line 2011 Applicat ion,Permit Application Revised 11-9., I I .docx Revised: Aussist 2011 bh Page 4 of4 Cash Register Receipt c ty of Tukwila DESCRIPTIONS ACCOUNT QLANTITY PermitTRAK PAID $691.33 D19-0056 Address: 3415 S 150TH ST Apn: 0041000515 $691.33 DEVELOPMENT $671.73 PERMIT FEE R000.322.100.00.00 0.00 $391.96 PLAN CHECK FEE R000.345.830.00.00 0.00 $254.77 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $19.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16875 R000.322.900.04.00 0.00 $19.60 $691.33 Date Paid: Friday, February 15, 2019 Paid By: CITY OF TUKWILA (JC1) Pay Method: ACCOUNT Printed: Friday, February 15, 2019 8:58 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3l0 Permit inspection Request Line (206) 438-9350 l?,cptJosz, Project: -Type of In ectio ff Address: Date Called: Special Instructions:Date Wanted: .�. ea a.m. P.m. ;Requester: Phone No•2:, 062 Approved per applicable codes. II Corrections required prior to approval. [COMMENTS: /#l✓DjNlf specto Date: REINSPECTI©N FEE REQUIRED. Prior to next inspection. fee must be paid at b300 Southcenter Blvd.. Suite 100. CaLL to schedule reiinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ' Type lnspection: Address: 274 f,Gi ' 4 t 5''7, Satre ailed: Special Instructions: D e '1l anted: Requester: 4Y1 J6 ( ° h Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. C,t tit 1-7-e'-v 5( 0 E Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: P 1 L4 Type of n ection: .7., - 0,1/, 1.)40118 Address: Date Called: Specia Instructions: Date Wanted: am. P-m- Requester: Phone No: LiaApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect° Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Btvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: C ( 4 . --C% Ty of of Ins ec on: WV-CP 0 Address: *-214// `''- 4, t 4.47"; Date C d: 0 I Special Instructions: Date nted: • • P- - Req ster: -ri Phone No: - 1 Approved per applicable codes. *COMMENTS: Corrections required prior to approval. nspecto Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd.. Suite 100. Call to schedule reinspection. 0�T|/�� l�/� /����JT���������� NOTICE /���— / �� CONTRACTOR /^r��� / ��/v CONSTRUCTION CONTRACTOR'S RE5PONS|B|L|TY Before bidding or starting any construction work, you are required to obtain a written asbestos report from the building owner orowner's agent. The report must bebased onasurvey byanaccredited AHERA building inspector unless the building owner assumes materials in the structure are asbestos or has other convincing documents showing asbestos is not present in the work area. 4building owner may know asbestos has been removed during prior work or that a new building haN been constructed using materials certified tobeasbestos free. If you discover suspect asbestos materials, you must report them to the building owner within 24 hours. Asbestos materials may be found in enclosed structures or between other materials, where they are not accessible before work. State law specifies a minimum $250 per day fine for failure to obtain the asbestos report. This fine can beapplied toboth the contractor and building owner. Additional fines may beapplied ifworkers are exposed to airborne asbestos. I Washington State Department of Labor & Industries regulations & policy with regards to asbestos removal, A Copy of the asbestos report must be made available to the building inspector prior to the first inspection. In addition, if asbestos has been found, confirmation of the completed abatement work must beprovided tothe building inspector. Inspection scheduling will not 6eaccepted until this documentation |sreceived bythe building inspector. LEGEND NOTES IIPARCEL:J FILE Permit No. Plan revew approval is subleCI to errors nO omissions Approval of construction oacumen does 101 aut oe he violation of any adopted c e or arOmaice Recut of approved Fielo Copy ana conditions is acKnowleOgec By Dae: Co of Tuoviia BUILDING DIVISION REVISIONS No changes snal! Oe made lo Ine Of WO vuonoui ,i0D101/31 of the Tukwila Building Division NOTE: Revisions will require a ne uhmdtal and may !nclude audilional p SITE PLAN JC-Overall r4 El: PI PARCEL: JC .1 ARCELJ 4 PARCEL: JC .6 ARCELJC, „.. CODE COMPLIANCE APPROVED EEO 271n City of Tu BUILDING DIVIr.„10 R CITY APPROVED FEB 26 2019 'Ay of Tukwila PUBLIC Vilork OLITION GENERA. NO ICERUONIPTESAPPLYTMEMSIES. 111ENEP SC, KNOIDIORTY MINESIEREMESATICK %BOOK= Mann. OnindMIXPOINFORDOTICIn n5IIIMICRYORNMA ARYFAUTAISKEPPINTO,NannAninna Wiliffe6401SFORDEMAIER,FAMEZ 144.409.0.11,00% liMERKIRM11100111311YAUN [PERU 111M45101444 af,DINATEOLLKMWASIAGEFORTSON RIEKINNEEMOIllinSPRESENIAMS. EMSIENOISEORMMInEflignVEND COMAIMIlliNIOnninnEVAIX COOKNATENCYMPIIMIlninSallannitOE MERIPINVECIRED. a tanglAnnIATPROPETannlanten nnYnefVOMOMPECTICOVIII SMIEnnintOMPILRECUVRIMEEngin 04110EMITMCMin. KYR ORMINEMEnifncnktPERMITN 111EMENCIFICIIIIMISMIIPEAF, Klannann 01401 n VALLYVIEWEVONICT9DEESPERFTR Vffka PIRIETSMMARAGENCYPERIMGAII0 NO1101101{ c. MOM XAMMEnnftinnTfil4 OM% CONFIROTHRRAYMWDIPPRINSIMI EVVIONSWIFERAOCARBZWE TO ISM PCSOLIIIMMTIONE4 FROVIE 1014PRIMMEORESSOBYKINR ratoommosomi IX(41101 1,010011KNEWKIMMEANSCFECASS ni171411X1 VIIME/MC0611P4 DISSIXISHIEM 411:11FYNCIllniktiMCFACISSKPM 13. WYE ViREMYkt USIMAIS,COM. immummeam,som MERBOIRS,n1t.ASMIRE01NEW4ti CMDIMPLCIVOMMIEUME Wag 1{. KinEfinEDSKROURK FO011e UMIAK REPSEBIORIBEIPSEPFMNIM PRICECI OK BECK ATICIPPNESCH I. AURVDISNIIKE VSCILSONIKMEOF nee MODISIMITIONFONSIABUS PRECSUCEDIENEk EOM fAMEPROTKIM11.01500/114E01,5 KEOUIPOROCIONCriMENDOWIVIOR MITROONFEASMPUFOR,EDIONS CONIACT. fehinnflananntMingManninnitti0F1 DE1411110MninatIVIAIDEARIGNIO PI,DOREV101i L DITICAMItnnititinERVERMISSICE OnnEnnAHORPSUKOMMCITECTEVEn Inc VNYAMINIMEAMWEMTIMCe MalCncinINRDIACAnnESTCCRUFS,Jfig COME. PANERRMIYKOMPRIa NCR teinlenfORTPNIMEn e 0,11150f1SPOPRIKAWDBECOMER MOM. EWENS ,101 TROUPE Alleg MISTOPE COMIC ESITEPL1101n14n1 E CEIVED F TUKWILA B1 OM PERMIT CENTER Noo 0 uJ 13 '12 —1 0 0 D' 0 0 2 111 r(i) ORTh LEGEND NOTES 1 ‘; PARCEL: JC • 6 PARCEL: JC .3 SITE PLAN JC-1 NORM SITE INFORMATION 00.000101Nat 0K006.1,010t0nairkiaa 10151E:20N PaRaanaaa EakaaavasieEMS1140=a0tsianaMEGATSNOSOMINN0410OonZailla SOLOalEviValaiStaalEaaNaTIOMENC0aastaaaSanol.PRIMai00,KEED ETIHSRSaElitafil001AMOFTRaNOWOM041C001005aDEOREC MERIVallana111110SiaMERSMTOMMUCORSOOLET0000061&40100 Man100100114800104001011.11RWaSPLOSOINFA0100,0904000aNtaaN Of1000CaNY0101a00010114011001171$001.a4900001aMENIP0,010103 0,2a0ErnaTTOIR64SP0PBECDIOILIZIMMONMOPPMDECIla 6.1 REVIEWED I -OR CODE COMPLIANCE • „ APPROVED FEB 27 2619 City of Tukwila BUILDING DIVISION eetwakloolka V.IZEMMVAIllt:X DEMOLITION GENERAL NOTES - uJ cc uJ 0 2 BOTINKISPictrfOalaelatIROPMETS HONISSAL FEIdalfalaaagaTalf&TENIETSATICiall NESP0056SION . aRYFROMaalaitagPAYeltaanalttiln P0BraniallinlantallA ARYFORSTA01.4074000(CO,REORKATE tr010101X0X(101800011CORAKSRMIR 1011110000016 .1£01WalklegaftWatOKUCANy iCalka 11£00gRACT0ASAI, t00610ALLOBIORONNAKEROPIMili Onet.ifarafFRAMERIPERISER01,05 EICE.0100£00t0001MilEPREAKKVEDIC C1001010000000101REPRESKANE COORKIRIS0E0M041MCDP111( mama 001/0)0aPaSEIRMSTYLINEASREM0 tavallEadalSEMIC1,11400E0 SailIMAMPICEEPRECOMTINSTIO NOURIMBYPTY0010RIA f0KankalakeaMPAINFORWERC070 0910100,140011110RADREMBE A0.00100a1004000010. a a011ENEMANICATESESKUTFOR PAISMiNPACOVVOnaGNI) amok aaol010NSTA1EMUNEEPB041706 ka0000110ta COMICIP00,0000C101(000aSnaN DEE0M01.000,000afERAOIMANZOSIX TOMATEOV0040010=a1E00,1003001if atealN0000001E0teMaYTIOVE 040000010A10014M00001MaCE 1.00ATCONHOIONCIMAIN0finas nialni0VM104 VERPLE=1400=4,000CaMEHAM 0100KitalkalitaRIWOHEIOSSEXIES. REMMElallarkatEMills,000A0 ktammeomatosons. ranauxurateromari 09a1Raitte1=1000SCREIVal ORaana PRESE=E050VOKOW00110,f100IM MailtMERVENVEVPORTSVAIM arafearXEMOMPONTAtakai AompsalagEOMSIPKIEW 00110144900064=00000SktanSUESaa Dat(100Y6ECIENDLWEA Plaw00411,14NantENSIN0LANIATERM aialECONIFONV000Nnagifilogia CONSIRUCIMATROMPERFORUOLOURTais conta Waha0f1100/40B41611AFIENMASAnsallot recumonannarogainsmcw =GOMM 0121004TERAISMOOTERE0E0M0100 OWNSE0Pasanalogyairailtaff== vENY=40101(101101401SINM0 DURCIONCATAMVEletlIgER9119i OFHP SEM PRMIEW0004003010POOKOARI OF=905010AaNadake 01000001EtarMaACCESSI0E00001000111 aNaSIPRMS001100005M E IXASIPROVIESTDEOMSE, SEESnalataka PADV010M010000000M0 = FAMIMaliElEallg)TOBEDME RECEIVED CITY OF TUKNILA FEB 1 4 2019 0 uJ 0 11.1 rt PERMIT CENTER CPERMIT COORD COPY C) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0056 PROJECT NAME: CITY OF TUKWILA (JC-1) SITE ADDRESS: 3415 S 150r" ST X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Building Division pi I it - Public Works or DATE: 02/14/19 _ Revision # before Permit Issued Revision # after Permit Issued Fire Prevention Structural LI Nanning Division Permit Coordinator r PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/14/19 Structural Review Required REVIEWERS INITIALS: DATE: 11111111111111111111811111111111111111111111111111111111111111111, APPROVALS OR CORRECTIONS: Approved DUE DATE: 03/14/19 Approved with Conditions n Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire Ei Ping E PW D Staff Initials: 12/18/2013 BMW Espahol Contact Search L&I Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-Z index Help My 1.&.1 Workplace Rights Trades & Licensing BNBUILDERS INC Owner or tradesperson Principals BASTIAN, BRADLEY JAMES, PRESIDENT FINLAY, RICHARD MORSE, CHIEF FINANCIAL OFFICER NIELSEN, JEFFREY J, VICE PRESIDENT (End: 09/07/2017) O'BRIEN, TIMOTHY D, CHIEF FINANCIAL OFFICER (End: 09/07/2017) Doing business as BNBUILDERS INC 2601 4TH AVE STE 350 SEATTLE, WA 98121 206-382-3443 KING County WA UBI No. Business type 602 056 687 Corporation Governing persons BRADLEY JAMES BASTIAN JEFFREY JON NIELSEN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations, Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BNBUII*990K3 Effective — expiration 05/23/2001— 09/15/2019 Bond Western Surety Co Bond account no. 929643038 $12,000.00 Received by L&I Effective date 06/08/2017 06/02/2017 Expiration date Until Canceled Bond history Insurance Liberty Mutual Fire Insurance Policy no. TB2Z91469482028 Received by L&I $1,000,000.00 Effective date Help us improve