Loading...
HomeMy WebLinkAboutPermit D19-0159 - TORRID - STORAGE RACKSTORRID - RACKING 17580 SOUTHCENTER PKWY AP N : 2623049110 EXPIRED 05/31/2021 D19-0159 ~/ y-\ Parcel No: Address: ��^�xx °�� Tukwila ~~K~� uvo n U�m`wm�oa Department of Community Development 630USou,hcenuerBoulevard, Suite #1VV Tukwila, Washington 98188 Phnne:30G'431'367O Inspection Request Line: Jo6'43O'935O Web site: http://m/ww.Tukwi|aVVA.nov DEVELOPMENT PERMIT 2623049110 Permit Number: Project Name: TORRID - RACKING Issue Date: Permit Expires On: D19'Ol59 9/Z4/2Ol9 3/22/2020 Address: Contact Person: Contractor: Name: Address: License No: Lender: Name: Address: K|nTVKVV|LAO5O LLC 3333NEW MYDEPARK RD#1OUC/O K|MOOREALTY CORP, POBOX 50Z0 NEW HYDEPK,CA, 11O4I 1230mOPTOLAAVE, TORRAm[�CA, 90501 SH|OMOLEDEVELOPMENT UI 28lIFAIRVIEW AVE,SUITE lOUZ' SH|BDL9I2K7 ''' Phone: (310)702'7852 Phone: (206)777`2087 Expiration Date: 6/11/2021 DESCRIPTION OF WORK: INSTALLATION OF STOCKROOM SHELVING FOR EXISTING RETAIL SPACE, NON HIGH PILE 10'-4" MAX Project Valuation: $5,00000 Type ofFire Protection: Sprinklers: YES Fire Alarm: YES Type ofConstruction: U|B Electrical Service Provided by: TUKWILA Fees Collected: $351.50 Occupancy per IBC: PW Water District: H|GHUNE'TUKVV|U\ Sewer District: TUKWILA Current Codes adopted bythe City ofTukwila: international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVACZg6'4GB: y Code: Public Works Activities: [hanne|badon/StripinQ: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Mau|ing/OversizeLoud: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signatu Volumes: Cut: O Fill: V Number: 0 No ^� &Y �*���� Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction or the performance of work. I am authorized to sign and obtain this develop. -a oermit and adge to the conditions attached to this permit. Signature: ( Print Name: %� Date: 'T '� /// 0 "/` ' This permit shall become null and void ifthe work bnot commenced within l8Odays for the date ofissuance, orif the work is suspended orabandoned for aperiod nfl80days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site ofwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center, Rack storage over 8-feeLinheight shall beanchored nrbracedtopeventnvertumingnrdisp|onementduhnAseismic events, The design and calculations for the anchorage orbracing shall heprepared byoregistered professional engineer licensed |nthe State ofWashington, Periodic special inspection isrequired during anchorage ofstorage racks 8feet orgreater inheight. 6: VALIDITY OFPERMIT: The issuance nrgranting ofapermit shall not beconstrued tobevpermit for, oran approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming togive authority tnviolate orcancel the provisions nf the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based unconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data, / 1 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 7: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 8: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 9: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 11: Maintain fire extinguisher coverage throughout. 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 14: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 15: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 16: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 20: Install mechanical stops in the tracks or on the rack structure to ensure a 6 inch transverse flue space is maintained every 4 ft along the length of the racking when the units are rolled together. Contact Al Metzler at 206-971-8718 if additional clarification is needed. 17: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC r CITY OF TUla LA Community Development Department Public Works Departmenrt Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/7www.TukwilaWA.gov Building Pernurisin. Project No. Date Application Accepted: E-14; Date Application Expires: I lc/ (For al ce use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 17580 Southcenter Parkway Tenant Name: Torrid King Co Assessor's Tax No.: Suite Number: 21 PROPERTY OWNER Name: Kimco Realty Address: 4065 Factoria Square Mall SE City: Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Jacob Webster Address: 1236 Portola Ave City: Torrance State: CA Zip: 90501 Phone: 310-702-7852 Fax: Email: websterjacob@aol.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: HAApplicalions\Forms-Applications Line1201 1 ApplicationsTermit Application Revised - 8-9-11 docx Revise& August 2011 Floor: New Tenant: .....Yes Li ..No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Rolf Armstrong Address: 376 SW Bluff Dr City: Bend State: OR Zip: 97702 Phone: (541) 389-9659 Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 bh NG PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ 5,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Installation of stockroom shelving for existing retail store. Non high pile 104" max. Will there be new rack storage? .....Yes Ej.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 4,100 500 NA NA II-B M 2nd Floor 3rd Floor Floors thru Basement Accessory S re* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? D Yes No If -yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [L1 ..... _Sprinklers IZ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes gl No If "y•es', attach list of materials and storage locations on a separate 8-112- x I I paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0....—On-site Septic System For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplicationsTorms-Applications On Line O011 Applicat lonsTermit Application Revised - S-9-11 doe,: Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT F IATION — 206-433-0179 Scope of Work (please provide detailed information): Tenant Improvement for Torrid retail store. Work to include new non bearing partitions, flooring, finishes, sales fixtures, new lighting, fitting rooms, restroom, cashwrap Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ... Water District #125 0 ...Water Availability Provided Sewer District 0 ...Tukwila 0 ...Sewer Use Certificate 0...Valley View 0,. Sewer Availability Provided Highline 0 .. Renton .. Renton Seattle Septic System: 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ...Civil Plans (Maximum Paper Size — 22" x 34") O ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance Easement(s) Proposed Activities (mark boxes that applv): El ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 0 ...Total Cut 0 ...Total Fill cubic yards cubic yards Geotechnical Report .. Maintenance Agreement(s) 0...Traffic Impact Analysis 0...Hold Harmless — (SAO) ,.. Hold Harmless — (ROW) .. Right-of-way Use - Profit for less than '72 hours .. Right-of-way Use — Potential Disturbance o .. Work in Flood Zone .. Storm Drainage 0 ...Sanitary Side Sewer 0 .. Abandon Septic Tank El .. Grease Interceptor 0 ...Cap or Remove Utilities 0 .. Curb Cut El .. Channelization 0 ...Frontage Improvements 0 .. Pavement Cut 0 .. Trench Excavation El ...Traffic Control 0 .. Looped Fire Line 0 .. Utility Undergrounding El ...Backflow Prevention - Fire Protection Irrigation Domestic Water 0 ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size .. WO # 0 ...Water Only Meter Size WO # 0...Deduct Water Meter Size 0 ...Sewer Main Extension.............Public El Private 0 ...Water Main Extension Public O Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City. State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip \ApplicationsWorms-Applications On Line \20I I Applicanons1Permit Application Revised - 6-9- 11.docx Revised: August 2011 Page 3 of 4 PERMIT APPLICATION NO I ES — / Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible'revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT Signature: Print Name: Jacob W Mailing Address: 1236 Portola Ave 1-1',Applicatiorts \Forms -Applications On Line1201 1 Applioations1Permit Application Revised - S-9-11 doe:, Revise& August 2011 bh Date: 5-0.-/2 Day Telephone: 310-702-7852 Torrance CA 90501 City State Zip Page 4 of 4 DESCRIPTIONS` PermitTRAK $351.50 D19-0159 Address: 17580 SOUTHCENTER PKWY Apn: 2623049110 $351.50 DEVELOPMENT $341.90 PERMIT FEE R000.322.100.00.00 0.00 $192.06 PLAN CHECK FEE R000.345.830.00.00 0.00 $124.84 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $9.60 TECHNOLOGY FEE TOTALFEES PAID BY RECEIPT: R17672 R000.322.900.04.00 0.00 $9.60 $351.50 Date Paid: Thursday, May 16, 2019 Paid By: JACOB WEBSTER Pay Method: CHECK 1389 Printed: Thursday, May 16, 2019 11:13 AM 1 of 1 SYSTEMS ECLI PSE ECLIPSE-ENGINEERING.COM ENGINEERING Structural Calculations Steel Storage Shelving By Mobile Media Storage Solutions • PO #199830SC Torrid - Store #5722 Parkway Super Center 17580 Southcenter Pkwy - Space #21 Tukwila, Washington 98188 Prepared For: Mobile Media Storage Solutions PO Box 177 Pine Bush, NY 12566 MAY 13 2019 .EVIEVVED FOR `I.JIDE COMPLIANCE APPROVED MAY 24 2019 City of Tukwila BUILDING DIVISION RECER'ED CITY OF TU KWILA MAY 16 2019 PERMIT CENTER 0159 Please note: The calculations contained within justify the seismic resistance of the shelving for both vertical and lateral forces as required by: the 2012/15 IBC, ASCE 7-10, and ANSWIRMI-MH16.1 (2012). These storage shelves are not accessible to the general public MISSOULA WHITEFISH Weet 1,4.1k. Sete 8, Ikeoule. UT SW32 Pim", (M) 721-6/33 • Fe. (0) 55247138 9L9 Nixon* ewe. SUM 102 Wiedsh,117 58837 Mow (M) arazis • Fox oce) 5524788 SPOKANE BEND PORTLAND 421 Well Merida kw. SAW 421 Spokane, WA 89201 (Awn goa) en-n3i • Roc WON 552-4788 31 SW Eke Own% &Ye 8, Bend, OR fiT/722 Mane: (541) 389-8858 • Far. (OS 562-4788 111 SW Ckenble Shut Sella IMO Point OR 97201 Mac (503) 395-1229 • Fa (406) 662-47138 . smG|mE ER|ws Torrid ' Store #5722 Tukwila, Washington 98188 RVC 5/9/2019 MOBILE MEDIA STORAGE SOLUTIONS STEEL STORAGESHELVING-LIGHT RETAIL CODES: Current Editions of the: IBC & CBC & ASCE 7 & RMI Design AK%����� S���AS������Sh�A�y^��� ���^c08F��K�n;t . � � .. Shelving Gwometry- HeiQhtofShe|vingUnit= Width of Shelving Unit = Depth of Shelving Unit = Number ofShelves/Unit = Vertical Shelf Spacing = Back toBack Units? Are There Mobile Units? Shelving Loading' Live Load per Shelf = Maximum Weight per Shelf = Dead Load per Shelf = Weight ofEach Post = Weight ofMobile Carriage = Floor Load Calculations: Total Load on Each Post = Total Load OnEach Unit = Floor Area Load = Allowable Floor LoadinQ= l[iO 3.5 3.0 7 19.5 YES YES 10 5] 1.5 7.5 so ft ft ft in osf |bs psf |bs |bs Floor Load Under Shelf = 91 psf Seismic Information - Importance Factor Site Class ' Mapped AcceiParameters: S,= 1.441 5,= 0.537 Steel Yield Stress = 33 ksi Modulus ofE|ost. = 29800 ks| Eff. Length Factor= 1.7 Unbraced Length,x= 19.5 in Unbraced Length,y= 19.5 in Type ofPost? 14ga Upright Posts Type of Beam? DRL Low Profile Display OnPlaque Near Shelving Units Per1.Bt Wide Shelf Wire Grid Shelf Material For Main Floor Slab onGrade OK FOR 100psf RETAIL FLOOR LOADING lU Not Open tothe Public D Worst Case Assumed F,=1.0OO Structural System 'A3CE 7Section 15.5.3 Steel Storage Shelving: R= 4 Average Roof Height = Height of Base Attachment = Shear [oeffBoundaries = V~-=Ol}42 Sm,= 1/441 3mz=O.8OS SD[: D =O.961 0'-0"For Ground Floor Location Ground Floor Adjusted For ASD *.00'�~mr--N N 0���~�� Z��.� N�N �~���� sms|mEsm|ws Torrid ' Store #S722 Tukwila, Washington 98l08 5/9/2019 RVC Lateral Force Distribution: per ASCE 7 Section 15.5,3.3 Total Dead Load per Shelf = 243 |bs Total Live Load per Shelf = 105 |bs Lateral DLForce per Shelf = 4.1 |bs Lateral LLForce per Shelf = 17.7 |bs 67Y6ofLLForce per Shelf = 11.8 |bs Total DLBase Shear = 28.6 |bs Total LLBase Shear = 12I6 |bs bU: Each Shelf isLoaded tm6796mfits Live Weight HeiRht: Load: h1= 3 in 53 |bs h2= 23in 53!bs h3= 42in 53|bs h4= 62in 53|bs hS= Dlin 53|bs h6= 101|n 53|bs h7= 120in 53|bs h8= Oin O|bs h9= 0 in O |bs h10= 8in O|bs 1111= 0 in 0 |bs h12= Oin 0|bs h13= O in U |bs 1114= Uin O|bs h15= Oin O|bs LC 2;Top Shelf Only isLoaded tm100%mf its Live Weight Cumulative Moment: 40749 in'|bs Controlling Load Case 8yInspection Latera|Force/5he|f: F1= 0.8 |bs F2= 5.8 |bs F3= 10.9 |by F4= 15.9 |by F5= 21.0 |bs FG= 26.0 |La F7= 31.1 |bs F8= 0.0 |bs F9= 0.0 |bs F10= 0.0 |bs F11= 0.0 \bs F12 = 0.0 |bs F13= 0.0 |bs F14= 0.0 |by F15= 0.0 |bs Total Base Shear = 46.3 lbs Does Not Control By inspection, the force distribution for intermediate shelves without live load (case 2) is negligible. Calculate the moment for each column based on the total seismic base shear for each shelf being loaded to67Y6ofit's allowable live weight. The column atthe center ofthe shelving system isthe worst case for this condition. 2 EmG|NEER|NG Tukwila, Washington 98188 Torrid ' Store #5722 5/9/2019 RVC Column CaUcuUat^ons-Comb~ned Bending and Axial Post TVpe: Double Rivet "L" or "T" Post VVidth= Depth= ThicknesS= E= Column Bending Calculations ' Max Column Moment 11.2 ft-lbs Allowable Bending Stress = 19.8 ksi Bending Stress on Column = 3.4 ksi Column Deflection Calculations - Max Deflection = 0.084 in Deflection Ratio= 1421 Allowable Deflection = 6 in Shelf Rivet Cqnnect|on- DianneterofRivet= Shear onEach Rivet = 8rQCapacity ofRivet = 0.25 89.9 519.8 in |bs |bs Allowable Shear Stress = 13.5 kai Shear Stress on Rivet= 1.8 ksi Column Axial Calculations ' Per "[Post DL+PL= 113 |bs DL+PL+EQ= 354 |bs Column CapacitV Calculations - Controlling Buckling Strese= Allowable Comp. Stress = Factor of Safety for Comp. = Nominal Column Capacity = Allowable Column Capacity = Static Axial Load on Column = 3112 1729 113 |bs |bo |bs Combined Bening And Axial Forces - Critical Buckling Load = 15527 |bs Axial Stress Unity= 8.205 Bending Stress Unity = 0.147 Combined Stress Unity = 0.352 rX= 0.470 in S= 0.04 in3 L= 0.060 in4 A.= 0.220 in2 Ae= 0.157 in2 Bending Stress OK At Top of Unit Max Deflection = 5% of Height Deflection OK Brg Stress OK Shear Stress OK RK4|Load Combination #1 RMI Load Combination #6 Axial Load OK Magnification Factor 0i987 Cm= 0.85 Column is Adequate 3 �.0 �0�C0 N PSE ENG|NEER|NG Tukwila, Washington 98188 Torrid ' Store #5722 5/9/2019 RVC Overturning and Anti -Tip Calculations Overturning Forces - Total Weight = 663 |bs Load Case 1:Dead Load +67%Live Load Total Lateral Force= 111 |bs Controlling Overturning Force Total Weight = 275 |bs Load Case 2:Dead Load +l00%Top Shelf Does Not Control Tension Force per Anchor = 113 /bs Per Side mfUnit Shear Force per Anchor = 56 |bs USE:'Nilti'HUS-EZ (or equivalent) POST INSTALLED ANCHOR BOLTS Allowable Tension Force = 736 |bs For 2SOOpsi Concrete Allowable Shear Force = 1056 lbs 3/8" Diameter x 2.5" Embedment Vertical Seismic Force = 44.6 lbs Combined Loading = 0.306 Anti -Tip Track Design ' Type ofAnti-Tip Device = Arm and Track Tension per Side = 113 |bs Capacity ofScrews toCarriage = 349 |bs Anti -Tip Yield Stress = 16 ksi Thickness Anti -Tip = 0.12 in Width ofAnti-Tip = 0.43 in Section Modulus ofLeg = 0.0092 in3 Allowable Stress on Leg = 16 ksi Bending Stress on Leg = 3.93 Anti -Tip Stress Unity = 0,246 ks| Section Modulus ofTrack = 0.090 in3 Spacing ofTrack A.8's= 24 in Bending Stress on Track = 3.75 Track Stress Unity = 0.235 ksi For Anchoring to Concrete Floor Anchors are Adequate (2) #12 Screws Are Adequate S863'TS Bending Stress OK G063'TS Bending Stress OK 4 �w� ECLIPSE m°—N NPSE ENG|NEER|NG Tukwila, Washington 98188 Torrid ' Store #S72I 5/9/2019 RVC Shelf Beam Calculations Shelf Beam Calculations: Steel Yield Stress = Modulus ofE|ast. = Beam Type: Area ofBeam = Section Modulus ofBeam = Moment ofInertia ofBeam = Shelf Width = Shelf Depth = Total Load/Shelf = Distributed Load= DRL Low Profile 33 ksi 29000 ksi DRL 0.168 0.020 0.014 3.S ft 1.5 ft 60 , |bs O.GJS plf Beam Type: Maximum Design Moment = Maximum Design Shear = Beam Bending Stresses = Beam Shear Stresses = Bending Stress Unity= Shear Stress Unity = Max Allowable Defection = Maximum Beam Deflection = Shelf Beam Rivet Check: Diameter of Rivet = Post Moment Shear on Rivet = Beam Shear onRivet = Resultant Shear = Brg Capacity of Rivet = Allowable Shear Stress = Shear Stress on Rivet= Shelf DL= 1.5 osf in2 in3 in4 /U|ovvab|e Bending Stress = 19.8 ksi Allowable Shear Stress = 13.2 ksi DRL ORH 13.2 15.1 8.0 0.09 0.406 0.007 0.233 in 0,072 in 8.25 in 89.9 |bs 15.1 |bs 81.1 |bs 519.8 |bs 9.6 ksi 1.9 hd ' DRC ft-lbs |bs ksi ksi Bending Stress OK Shear Stress OK ---- Deflection ON Brg Stress OK Shear Stress OK 5 ECLIPSE ENGINEERING Torrid - Store #5722 Tukwila, Washington 98188 5/9/2019 RVC Wall Supported Unit Calculations Seismic Force at Top of Units - Average Roof Height = 20.0 ft Height of Attachment = 10.0 ft Shear Coeff Boundaries = Vmin = 0.288 Vmax = 1.537 Design Base Shear Coeff = Vt = 0.343 Total Weight per Unit = 303 Ibs Lateral Force at Top/Bottom = 52 Ibs Standard Stud Spacing = 16 in Wall Connections per Unit = 2 Adjusted For ASD Tek Screw Capacity = 84 Ibs Tension Cap. for #10 Screw in 20ga Stud Force Per Connection = 26 Ibs 'Screw Capacity OK Seismic Uplift Force on Each Shelf Seismic Uplift on Shelves - Vertical Seismic Component = 23,2 Ibs Vertical Dead Load per Shelf = 120.8 Ibs Connection Points per Shelf = 4.0 Each Corner Net Uplift Load per Shelf = -49.2 Ibs Uplift Forcer per Connection = -12.3 Ibs Rivet Connection OK 6 �*0 ECN N PS sws|wssR|ms Tukwila, Washington 98188 Torrid ' Store #S7I2 S/9/2O19 RVC Light Gage Steel Stud Wall Framing Stud Design Data ' Height ofWall Studs = 16.0 f1 Location ofPoint Load = 18.0 ft Design Lateral Load = 26.0 |bs Additional Lateral Load = 5.0 psf DesignAxia| Load= 85.3 |bs Spacing ofStuds = 16.8 in Int. Non-Brg - Worst Case Ht Assumed From Shelving Unit Interior Seismic Force Dead Load ofWall Framing TRY: 3-5/8"x1-5/8"x 20saStuds @1G"o.c.(Worst Case Assumed) \Nidth= I625 in Deoth= 1.625 in Thickness= 0.035 in Fv= ]3 ksi E= 29000 ksi K= 1.0 rw = 1.450 in ry= 0.616 in 5x= 0.268 in3 |x= U.SS1 in4 Ap= 0.26I in2 UnbnacedLength X= 16 f1 UnbraccdLength Y= 4 ft Stud CaAacitv' Buckling Stress, X= 16.32 ksi Buckling Stress, Y= 47.14 ksi Allowable Buckling Stress = 16.32 ksi Nominal Axial Strength = 4277 |bs Factor ofSafety = 1.92 Allowable Axial Load = 2228 |bs Maximum Design Moment = 310.9 ft-|bs Maximum Design Shear = 69.6 |bs /U|ovvab|e Bending Stress = 21.78 ksi Actual Bending Stress = 13.92 ksi Allowable Shear Stress = 13.30 ksi Actual Shear Stress = 0.27 ksi Allowable Axial Stress = 8.50 ksi Actual Axial Stress = 0.33 ksi Combined Stress Unity = 0.68 Bending Stress OK Shear Stress OK Axial Stress OK Combined Stress OK 7 t�*���m��N N ������ � ��� N—N �~���� ENG|NEER|NG Tukwila, Washington 98188 Torrid ' Store #E7%2 5/Q/JO23 RVC Slab Bearing & Uplift Calculations Slab DesignPropmrues- Minimunn Concrete Strength = Thickness of Concrete Slab = Weight ofConcrete Slab = Allowable Bearing Pressure = Bearing Loads On Post = Uplift Loads onPost = Slab Bearing CapamitV- 2SOO psi Assumed 4 in Assumed SO psf 35 |bs Dead Load 184 |bs Live Load 267 |bs E[}Load 113 lbs Resultant Uplift Depth ofPost on Slab = 1.5 in Factored Bearing Load = 717 |bs Required Bearing Area = 139.86 in2 Critical Section = 3.16 in Soil Pressure onCrit.Section = 738.5 plf Section Modu|us= 32.0 in3 Shear Area = 22 in Conc. Shear Stress = Q.] psi Allowable Shear Stress = 73.2 psi Conc. Bending Stress = 9.6 psi Allowable Bending Stress = 137.5 psi Slab Uplift Capacitv - Required Area toResist Uplift = Length ofSlab Req'd= Worst Case Length ofSlab = Distance toAnchor Bolt = f2 ft ft ft Shear Force on 1ft Strip= 123.5 |bs Allowable Shear Force = 1760.0 |bs Bending Moment onIftStrip = 107.2 ft-|bs 11.83 inches per side For Bending Along Critical Length Plain Concrete per Foot Shear Stress OK Bending Stress OK Assume Full Shelf Width xReq'dLength Bending OK ^ !-*O0��°—'N N0~��~0_ ����� N�N �~���� swG|wEsn|mG Torrid ' Store #5722 Tukwila, Washington 9818Q RVC S/9/2O19 ^ MOBILE MEDIA STORAGE SOLUTIONS STEEL STORAGE SHELVING ' LIGHT RETAIL CODES: Current Editions of the: IBC & CBC & ASCE 7 & RMI Design Inputs: Steel Storage Shelving: Typical HANG Unit Shelving Geometry- HeightofShe|ving Unit = 10.0 ft Width ofShelving Unit = IS ft Depth ofShelving Unit = JO ft Number ofShelves/Unit = 4 Vertical Shelf Spacing = 39.0 in Back toBack Units? YES Are There Mobile Units? YES ShmhdngLoading- LiveLqadperShe|f= Maximum Weight per Shelf = Dead Load per Shelf = Weight ofEach Post = Weight ofMobile Carriage = Floor Load Calculations: Total Load onEach Post = Total Load OnEach Unit = Floor Area Load = Allowable Floor Loading = 0 53 1.5 7.5 SO 68 593 10.5 100 osf |bs psf |bs |bs |bs |bs f2 psf Floor Load Under Shelf = 56 uuf Seismic Information - Importance Factor ' Site Class ' Mapped AzceiParameters: S' = 1.441 3,= 0.537 Steel Yield Stress = 33 ksi Modulus ofE|ast. = 29000 ksi Eff. Length Factor= 1.7 Unbraced Length,x= 39.0 in Unbraced Length,y= 39.0 in Type nfPost? l4OaUpright Posts Type of Beam? DRL Low Profile Display OnPlaque Near Shelving Units Per1.5ft Wide Shelf Wire Grid Shelf Material For Main Floor Slab onGrade OK FOR 100psf RETAIL FLOOR LOADING 1.0 Not Open tothe Public D Worst Case Assumed F=1.00 Structural System -ASCE 7 Section 15.5] Steel Storage Shelving: R= 4 Average Roof Height = ZO ft Height of Base Attachment = 0 ft Shear Coeff Boundaries = V_-=Ol4J S,,=1.441 SDC: D av=2.5 |p=1]J 0'-O"For Ground Floor Location Ground Floor Adjusted For ASD 9 ECLIPSE ENGINEERING Torrid - Store #5722 Tukwila, Washington 98188 5/9/2019 RVC Lateral Force Distribution: per ASCE 7 Section 15.5.3.3 Total Dead Load per Shelf = 30.7 Ibs Total Live Load per Shelf = 105 Ibs Lateral DL Force per Shelf = 5.2 Ibs Lateral LL Force per Shelf = 17.7 Ibs 67% of LL Force per Shelf = 11.8 Ibs Total DL Base Shear = 20.7 Ibs Total LL Base Shear = 70.6 Ibs LC1: Each Shelf is Loaded to 67% of its Live Weight Cumulative Moment: 24864 in-Ibs Total Base Shear = 68.0 Ibs Height: Load: h1 = 3 in 53 Ibs h2 = 42 in 53 Ibs h3 = 81 in 53 Ibs h4 = 120 in 53 Ibs h5= 0in 0lbs h6 = 0 in 0 Ibs h7 = 0 in 0 Ibs h8 = 0 in 0 Ibs h9 = 0 in 0 Ibs h10 = 0 in 0 Ibs h11= 0 in O lbs h12 = 0 in 0 Ibs h13 = 0 in 0 Ibs h14 = 0 in 0 Ibs h15 = 0 in 0 Ibs % Per Shelf: 1.2% 17.1% 32.9% 48.8% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Controlling Load Case By Inspection Lateral Force/Shelf: F1 = 0.8 Ibs F2 = 11.6 Ibs F3 = 22.4 Ibs F4 = 33.2 Ibs F5 = 0.0 Ibs F6 = 0.0 Ibs F7 = 0.0 Ibs F8 = 0.0 Ibs F9 = 0.0 Ibs F10 = 0.0 Ibs F11 = 0.0 Ibs F12 = 0.0 Ibs F13 = 0.0 Ibs F14 = 0.0 Ibs F15 = 0.0 Ibs Sum = 100% Total = 68.0 Ibs LC 2: Top Shelf Only is Loaded to 100% of its Live Weight Total Base Shear = 38.3 Ibs Does Not Control By inspection, the force distribution for intermediate shelves without live load (case 2) is negligible. Calculate the moment for each column based on the total seismic base shear for each shelf being loaded to 67% of it's allowable live weight. The column at the center of the shelving system is the worst case for this condition. 10 �'0 OECN N PSE swG|wEsR|mG Torrid ' Store #S72I Tukwila, Washington 98188 5/9/2019 RVC Column Calculations .Combined Bending and Axial PostTvpe: Double Rivet "["or"T"Post VVidth= Depth= Thichness= E= Column Bending Calculations ' Max Column Moment 13.6 ft-lbs /U|ovvab|e Bending Stress = 19.8 ksi Bending Stress on Column = 4.1 hsi Column Deflection Calculations - Max Deflection = 0.221 in Deflection Ratio = 542 Allowable Deflection = 6 in Shelf Rivet Connection - Diameter ofRivet = Shear onEach Rivet = Br0Capacity ofRivet= 0.25 109.1 519.8 in |bs |bs Allowable Shear Stress = 13.5 ks\ Shear Stress on Rivet = 2.2 ksi Column Axia|Calculatkvns- Per "L"Post DL+PL= GB |bs DL+PL+E[l= 228 |bs Co|urnmCapacitV Calculations ' Controlling Buckling Stress = Allowable Comp. Stress = Factor of Safety for Com p. = Nominal Column Capacity = Allowable Column Capacity = Static Axial Load onColumn = Combined Bending And Axial Force Critical Buckling Load = Axial Stress Unity= Bending Stress Unity= |6s |bs |bs 3907 |bo 0.247 0.181 Combined Stress Unity = 0.428 r.= 0/470 in 5`= 01040 in] |x= 8.060 in4 A.= 0.220 in3 Ae= 0.157 in2 Bending Stress OK At Top of Unit Max Deflection = 5% of Height UA Deflection OK Brg Stress OK Shear Stress OK RM|Load Combination #1 RM|Load Combination #6 Axial Load OK Magnification Factor 0.969 ["= 0.85 Column is Adequate 11 ECLIPSE ENGINEERING Torrid - Store #5722 Tukwila, Washington 98188 5/9/2019 RVC Overturning and Anti -Tip Calculations Overturning Forces - Total Weight = 404 Ibs Load Case 1: Dead Load + 67% Live Load Total Lateral Force = 68 Ibs Overturning Force = 523 ft*Ibs Controlling Overturning Force Total Weight = 228 Ibs Load Case 2: Dead Load + 100% Top Shelf Total Lateral Force = 38 Ibs Overturning Force = 347 ft*Ibs Does Not Control Tension Force per Anchor = 80 Ibs Per Side of Unit Shear Force per Anchor = 34 Ibs USE: 'Hilti' HUS-EZ (or equivalent) POST INSTALLED ANCHOR BOLTS Allowable Tension Force = 736 Ibs For 2500 psi Concrete Allowable Shear Force = 1056 Ibs 3/8" Diameter x 2.5" Embedment Vertical Seismic Force = 27.2 Ibs Overstrength Factor = 2 Combined Loading = 0.219 Anti -Tip Track Design - Type of Anti -Tip Device = Arm and Track Tension per Side = 80 Ibs Capacity of Screws to Carriage = 349 Ibs Anti -Tip Yield Stress = 16 ksi Thickness Anti -Tip = 0.12 in Width of Anti -Tip = 0.43 in Section Modulus of Leg = 0.0092 in3 Allowable Stress on Leg = 16 ksi Bending Stress on Leg = 2.81 ksi Anti -Tip Stress Unity = 0.175 Section Modulus of Track = 0.090 in3 Spacing of Track A.B's = 24 in Allowable Alumn. Stress = 16 ksi Bending Stress on Track = 2.68 Track Stress Unity = 0.167 ksi For Anchoring to Concrete Floor Anchors are Adequate (2) #12 Screws Are Adequate 6063-T5 Bending Stress OK 6063-T5 Bending Stress OK 12 t �000�u�—N N���~�_ ' ��N�� N_N �~���. ENG(NEER|NG Torrid - Store #S722 Tukwila, Washington 98l88 5/9/2019 RVC Shelf Beam Calculations Shelf Beam Calculations: D0ILLow Profile Steel Yield Stress = 33 ksi Shelf DL= 1.5 osf Shelf LL= 10.00 psf Beam Type: DRL DRH {Dl[ Area ofBeam = 0.168 0L377 O in2 Section Modulus ofBeam = 0.020 0.219 O |m3 Moment ofInertia ofBeam = 0.014 0.220 O |n4 Shelf Width = 3.5 ft /Q|pvvable Bending Stress = 19.8 ksi Shelf Depth = 1.5 ft Allowable Shear Stress = 13.2 ksi Total Load/Shelf = GO |bs Distributed Load= 8.625 p|f Beam Type: DRL DRH DR[ Maximum Design Moment = 13.2 ft-lbs Maximum Design Shear = 15.1 |bs Beam Bending Stresses = 8.0 ksi Beam Shear Stresses = 0.09 ksi Bending Stress Unity = 0/406 Shear Stress Unity = 0.007 Bending Stress OK Shear Stress OK Max Allowable Deflection = 0,233 in L/188 Maximum Beam Deflection = 0.072 in Shelf Beam Rivet Check: Diameter of Rivet = 0.25 in Post Moment Shear onRivet = 109.1 |bs Beam Shear onRivet = 15.1 |bs Resultant Shear = 110.1 |bs Br0Capacity nfRivet = 519.8 |bs Allowable Shear Stress = 9.6 ksi Shear Stress on Rivet = 2.2 ksi Deflection OK Brg Stress OK Shear Stress OK 13 �-�� 0_CN LIPS E EmG|NEER|NG Tukwila, Washington 98188 Torrid - Store #B%2 5/9/2O19 RVC Slab Bearing & Uplift Calculations Slab Design Properties - Minimum Concrete Strength = Thickness VfConcrete Slab = Weight ofConcrete Slab = Allowable Bearing Pressure = Bearing Loads On Post = Uplift Loads on Post = Slab Bearing Capacity - 2500 psi Assumed 4 in Assumed 50 psf 23 |bs Dead Load 105 |bs Live Load 174 |bs EDLoad 80 lbs Resultant Uplift Depth ofPost onSlab = 1.5 in Factored Bearing Load = 445 |bs Req u i red Bea ri ng Area = 87.18 in3 Critical Section = 1.92 in Soil Pressure onCrit.Section = 735,2 p|f Section Modulus = 22.0 in3 Shear Area = 22 in Conc. Shear Stress = 5.1 psi Allowable Shear Stress = 73.2 psi ConcBending Stress= 3.5 psi Allowable Bending Stress = 137.5 psi Slab Uplift Capacity- RequiredAreatoResistUp|Ut= Length ofSlab Req'd= Worst Case Length ofSlab = Distance toAnchor Bolt = f2 ft ft ft Shear Force on Ift Strip = 122.5 |b* Bending Moment on1tStrip = 107.2 ft-lbs 9.34 inches per side For Bending Along Critical Length Plain Concrete per Foot Shear Stress OK Bending Stress OK Assume Full Shelf Width xReq'dLength Maximum of Width or Length Req'd Bending OK 14 -'*00��"�N N N�,�~�� E ' --|— --- - /-- -- Tukwila, Washington 98l8B Torrid - Store #5722 5/9/2019 RVC MOBILE MEDIA STORAGE SOLUTIONS STEBLSTORAGESHELVING-LIGHT RETAIL [ODES: ' Current Editions ofthe: IBC &C8[hkAS[E7/&RM| Design Inputs: Steel Storage Shelving: Typical MARKETING Unit Shelving Gemmetry' Height ofShelving Unit = Width ofShelving Unit = Depth ofShelving Unit = Number ofShelves/Unit = Vertical Shelf Spacing = Back toBack Units? Are There Mobile Units? Shelving Loading' Live Load per Shelf = Maximum Weight per Shelf = Dead Load per Shelf = Weight ofEach Post = Weight ofMobile Carriage = Floor Load Calculations: Total Load onEach Post = Total Load On Each Unit= Floor Area Load = Allowable Floor Loading = 10.0 3.0 2.0 9 14.6 NO NO 10 60 2.5 7.5 176 705 7.0 100 ft ft ft in osf |bs psf |bs |bs |bs |bs f2 psf Floor Load Under Shelf = 100 psf Seismic Information ' Importance Factor ' Site Class ' Mapped AcceiParameters: 5,=1.441 5z=0.537 Steel Yield Stress = 33 ksi Modulus ofE|ast.= 29000 ksi Eff. Length Factor = 1.7 Unbraced Length,x= 14.6 in Unbraced Length,y= 14.6 in Type ofPost? I4ga Upright Posts Type ofBeam? DRLLow Profile Display OnPlaque Near Shelving Units PerJf1 Wide Shelf Particle Board Shelf Material For Main Floor Slab onGrade OK FOR 100psf RETAIL FLOOR LOADING 1.0 Not Open tothe Public D Worst Case Assumed Fo= 1.OUO Structural System 'ASCE 7 Section 15.5.3 Steel Storage Shelving: R= 4 Average Roof Height = ZU ft Height ofBase Attachment = O ft Shear Coeff Boundaries = V,,i,=UIk�l S,= 1/44l 5nu= 0.805 an= 2.5 5D[: D |n= 1.0 O'-O"For Ground Floor Location Ground Floor Adjusted For ASD 15 ECLIPSE ENGINEERING Torrid - Store #5722 Tukwila, Washington 98188 5/9/2019 RVC Lateral Force Distribution: per ASCE 7 Section 15.5.3.3 Total Dead Load per Shelf = 18.3 Ibs Total Live Load per Shelf = 60 lbs Lateral DL Force per Shelf = 3.1 Ibs Lateral LL Force per Shelf = 10.1 Ibs 67% of LL Force per Shelf = 6.8 Ibs Total DL Base Shear = 27.7 Ibs Total LL Base Shear = 90.8 Ibs LC1: Each Shelf is Loaded to 67% of its Live Weight Cumulative Moment: 32395 in-Ibs Total Base Shear = 88.6 Ibs Height: Load: h1= 3 in 60 Ibs h2 = 18 in 60 Ibs h3 = 32 in 60 Ibs h4 = 47 in 60 Ibs h5 = 62 in 60 Ibs h6 = 76 in 60 Ibs h7 = 91 in 60 Ibs h8 = 105 in 60 Ibs h9 = 120 in 60 Ibs h10 = 0 in 0 Ibs h11= 0 in 0 Ibs h12 = 0 in 0 Ibs h13 = 0 in O lbs h14 = 0 in 0 Ibs h15 = 0 in 0 Ibs % Per Shelf: 0.5% 3.2% 5.8% 8.5% 11.1% 13.8% 16.4% 19.0% 21.7% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Controlling Load Case By Inspection Lateral Force/Shelf: F1= 0.5 Ibs F2 = 2.8 Ibs F3 = 5.2 Ibs F4 = 7.5 Ibs F5 = 9.8 Ibs F6 = 12.2 Ibs F7 = 14.5 Ibs F8 = 16.9 lbs F9 = 19.2 Ibs F10 = 0.0 Ibs F11 = 0.0 Ibs F12 = 0.0 Ibs F13 = 0.0 Ibs F14 = 0.0 Ibs F15 = 0.0 Ibs Sum = 100% Total = 88.6 Ibs LC 2: Top Shelf Only is Loaded to 100% of its Live Weight Total Base Shear = 37.8 Ibs Does Not Control By inspection, the force distribution for intermediate shelves without live load (case 2) is negligible. Calculate the moment for each column based on the total seismic base shear for each shelf being loaded to 67% of it's allowable live weight. The column at the center of the shelving system is the worst case for this condition. 16 � *0 EC0 N PSE Torrid - Store #5722 5/9/2019 RVC Column CaUcuKat^ons-Cmmb^ned Bending and Axial Post Type: Double Rivet "L"mr"T"Post VWdth= Depth= Thickness= E= Column Bending Calculations ' Max Column Moment 13.4 ft-lbs Allowable Bending Stress = 19.8 ksi Bending Stress nn Column = 4.0 ksi Column Deflection Calculations ' Max Deflection = 0.074 in Deflection Ratio = 1619 Allowable Deflection = 6 in Shelf Rivet Connection ' Diameter of Rivet = Shear on Each Rivet = Brg Capacity of Rivet = in |bs |bs /A|ovvob|e Shear Stress = 13.5 ksi Shear Stress on Rivet= 2.2 ksi Co|wnnnAxia(Calculations- Per "L"Post DL+PL= 176 |bs DL+PL+E{l= 452 |bu Column Capacity Calculations - Controlling Buckling Stress = Allowable Comp. Stress= Factor of Safety for Comp. = Nominal Column Capacity = Allowable Column Capacity = Static Axial Load on Column = |bs |bs |bs Combined Bending And Axial Forces ' Critical Buckling Load = 27783 |bs Axial Stress Unity= 0.245 Bending Stress Unity= 0.175 Combined Stress Unity = 0.420 rX= 0.470 in Si= 0.040 in3 |,= 0.060 in4 A.= 0.220 in2 A-= 0.157 in3 Bending Stress OK At Top of Unit UA Max Deflection =S%ofHeight Deflection OK Brg Stress OK Shear Stress OK RK4|Load Combination #1 RMI Load Combination #6 Axial Load OK Magnification Factor 0.989 ["= 0.85 Column is Adequate 17 %ECLIPSE ENGINEERING Torrid - Store #5722 Tukwila, Washington 98188 5/9/2019 RVC Overturning and Anti -Tip Calculations Overturning Forces - Total Weight = 527 Ibs Load Case 1: Dead Load + 67% Live Load Total Lateral Force = 89 Ibs Overturning Force = 625 ft*lbs Controlling Overturning Force Total Weight = 225 Ibs Load Case 2: Dead Load + 100% Top Shelf Total Lateral Force = 38 Ibs Overturning Force = 273 ft*lbs Does Not Control Tension Force per Anchor = 190 Ibs Per Side of Unit Shear Force per Anchor = 44 Ibs USE: 'Hilti' HUS-E2 (or equivalent) POST INSTALLED ANCHOR BOLTS Allowable Tension Force = 736 Ibs For 2500 psi Concrete Allowable Shear Force = 1056 Ibs 3/8" Diameter x 2.5" Embedment Vertical Seismic Force = 35.4 Ibs Overstrength Factor = 2 Combined Loading = 0.516 Anti -Tip Track Design - Type of Anti -Tip Device = NONE Tension per Side = N/A Ibs Capacity of Screws to Carriage = N/A Ibs Anti -Tip Yield Stress = 16 ksi Thickness Anti -Tip = 0.12 in Width of Anti -Tip = 0.43 in Section Modulus of Leg = 0.0092 in3 Allowable Stress on Leg = N/A ksi Bending Stress on Leg = N/A ksi Anti -Tip Stress Unity = N/A Section Modulus of Track = 0.090 in3 Spacing of Track A.B's = N/A in Allowable Alumn. Stress = N/A ksi Bending Stress on Track = N/A ksi Track Stress Unity = N/A For Anchoring to Concrete Floor Anchors are Adequate N/A 6063-T5 N/A 6063-T5 N/A 18 k� 05Eyr~N NPS@_ sws|wssm|ms Tukwila, Washington 98188 Torrid - Store #5722 5/9/2019 RVC Shelf Beam Calculations Shelf Beam Calculations: Steel Yield Stress = Modulus ofE|ost. = Beam Type: Area ofBeam = Section Modulus ofBeam = Moment ofInertia ofBeam = Shelf Width = Shelf Depth = Total Load/Shelf = Distributed Load = 3.0 2.0 75 12.5 Beam Type: Maximum Design Moment= Maximum Design Shear = Beam Bending Stresses = Beam Shear Stresses = Bending Stress Unity = Shear Stress Unity = Max Allowable Deflection = Maximum Beam Deflection = Shelf Beam Rivet Check: Diameter ofRivet = Post Moment Shear on Rivet= Beam Shear onRivet = Resultant Shear = Brg Capacity of Rivet = Allowable Shear Stress = Shear Stress on Rivet = DIRL Low Profile 33 ksi 29000 ksi DRL 0.168 0.020 0.014 ft ft |bs p|f DRL 14.1 18.8 8.6 0.11 0.25 in 107.3 |bs 18.8 |bs 109.0 |bs 529.8 |bs 9.6 ksi 22 ksi DRH 0.277 O.219 0.220 Shelf DL= 3.5 oxf Shelf LL= 10.00 psf in2 in3 in4 /A|ovvab|e Bending Stress = 19.8 ksi Allowable Shear Stress = 13.2 ksi DRH DRC ft-|bs |bs ksi ksi Bending Stress OK Shear Stress OK Deflection OK Brg Stress OK Shear Stress OK 19 �.15 Eur--0 B PS E ENG|NEER|NG Tukwila, Washington 98188 Torrid ' Store #57J3 5/9/2O19 RVC Wall Supported Unit Calculations Seismic ForcwatTmpefUnOts- AvenageRoofHeight= 20.0 ft Height ofAttachment = 10.0 ft Shear Coeff Boundaries = V—ax —=1.537 Total Weight per Unit = 472 |bs Lateral Force at Top/Bottom = 81 lbs, Standard Stud Spacing = 16 in Wall Connections per Unit = 2 TekScrew Capacity = 84 |bs Adjusted For ASD I Tension Cap. for #10 Screw in 20ga Stud Screw Capacity OK Seismic Uplift Force on Each Shelf Seismic Uplift onShelves - Vertical Seismic Component = 14.4 |bs Vertical Dead Load per Shelf = 75.0 |bs Connection Points per Shelf = Net Uplift Load per Shelf = 4.0 Each Corner '3D.G |bs Uplift Forcer per Connection = -7.6 lbs Rivet Connection OK 20 � OooECLIPS Ems|mssR|ms Tukwila, Washington 98188 Torrid - Store #S7IZ 5/9/2019 RVC Light Gage Steel Stud Wall Framing Stud DesigmData- He|ghtofVVaUStuds= 16.0 ft Location of Point Load = 10.0 ft Design Lateral Load = 40.5 |bu Additional Lateral Load = 5J0 osf Design Axial Load = 85.3 |bs Spacing ofStuds = 16.0 in Int. Non-Brg'Worst Case HtAssumed From Shelving Unit Interior Seismic Force Dead Load of Wall Framing TRY: 3-6/0"m1'5/8"x 28saStuds @1G"o.c.(Worst Case Assumed) VWdth= 3.625 in Depth= 1.635 in Thickness= 0.035 in Fv]] ksi E= 23000 ksi K= 1.0 rx= 1,450 in ry= 0,6I6 in Sx= 0.368 in3 |x= 0.551 in4 Ap= 0.262 in2 UnbracedLength X= 16 ft Unbraced Length Y = 4 ft Stud Camacitw' Buckling Stress, X= 16.32 ksi Buckling Stress, Y= 47.14 ksi Allowable Buckling Stress = 16.32 ksi Nominal Axial Strength = 4277 |bs Factor of Safety = 1.92 Allowable Axial Load = 2228 |bs Maximum Design Moment = 365.3 ft-|bs Maximum Design Shear = 78.7 |bs Allowable Bending Stress = 21.78 ksi Actual Bending Stress = 16.35 ksi Allowable Shear Stress = 13.20 ksi Actual Shear Stress = 0.30 ksi Allowable Axial Stress = 8.50 ksi Actual Axial Stress = 0.33 ksi Combined Stress Unity = 0,79 Bending Stress OK Shear Stress OK Axial Stress OK Combined Stress OK 21 *0 ECLI PS E ENG|NEER|N5 Torrid ' Store #5722 Tukwila, Washington 9Q188 5/9/2019 RVC Slab Bearing &UpUift Calculations Slab Design Properties ' Minimum Concrete Strength = Thickness ofConcrete Slab = Weight ofConcrete Slab = Allowable Bearing Pressure = Bearing Loads On Post = Uplift Loads on Post = Slab Bearing CapacitV - 2500 psi Assumed 4 in Assumed 75 lbs Dead Load 270 |bs Live Load 313 |bs EC\Load 190 lbs Resultant Uplift Depth ofPost nnSlab = 1.5 in Factored Bearing Load = 968 |bs Required Bearing Area = 189.35 in2 Critical Section = 4.13 in Soil Pressure on[rb.Section = 736.5 plf Section Modulus = 33.0 in3 Shear Area = 22 in Conc. Shear Stress = 11.0 psi Allowable Shear Stress = 73.2 psi Conc. Bending Stress = 16.4 psi Allowable Bending Stress = 137.5 psi Slab Uplift CapacitV- Required Area |o Resist Uplift = Length ofSlab Req'd= Worst Case Length ofSlab = Distance toAnchor Bolt = 6.33 2.11 3.00 1.50 ft2 ft ft ft Shear Force on1ftStrip = 105.0 |bs Bending Moment onIft Strip = 78.8 ft-|bs 13.76 inches per side For Bending Along Critical Length Plain Concrete per Foot �hear Stress OK [Bending Assume Full Shelf Width xReqULength Maximum of Width or Length Req'd Bending OK 22 www.hilti.us ProAnchor 2.7.3 Company: Specifier: Address: Phone I Fax: E-Mail: Eclipse Engineering, Inc Robert VanCamp Page: Project Sub -Project I Pos. No,: Date: 5/31/2017 Specifier's comments: 1 Input data Anchor type and diameter: KWIK HUS-EZ (KH-EZ) 3/8 (2 1/2) A., * - • 1 ' Effective embedment depth: hEtaci = 1.860 in., h„,,r r- 2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued 1 Valid: 2/1/2016 112/1/2017 Proof: Design method ACI 318-14 / Mech. Stand-off installation: - (Recommended plate thickness: not calculated) Profile: no profile e 4 # _ At 4 Base material: cracked concrete, 2500, lc' 2500 psi; h = 4.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition 13; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E. or F) Tension load: yes (17.2.3.4.3 (b)) Shear load: yes (17.2,3.5.3 (a)) Geometry [In.] & Loading [lb, 'nib] NOTE: SHEAR AND TENSION FORCES ARE PROVIDED TO CALCULATE ANCHOR CAPACITY -REFERENCE THE CALCULATIONS FOR ACTUAL V & T AND UNITY CHECK • Input data and results must de checked for agreement with the wasting conditions and for plauelbilrly! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9.494 Schoen 1-1C9 is a registered Trademark of Hti AG, Schoen Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E-Mail: Eclipse Engineering, Inc Robert VanCamp Page: 2 Project: Sub -Project I Pos. No.: Date: 5/31/2017 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity ON i Pv rAi Status Tension Concrete Breakout Strength 300 1051 29 / - OK Shear Pryout Strength 100 1l509 - / 7 OK Loading PNUtilization Ittcv rie Status Combined tension and shear oad 0.285 0.066 4 OK 3 Warnings Please consider all details and hints/warnings given in the detailed report! Convert to ASD Multiply by 0.7 Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concem solely the use of Hilti products and are based on the principles. formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in, Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits. prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular. you must arrange for the regular backup of programs and data and. if applicable, carry out the updates of the Software offered by Hilti on a regular basis. II you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. input data and resuCts roost be checked for agreement with the esistmg conditions and for plausIbiityl PROFIS Anchor ( c )2003.2009 Hilti AG, FL-9494 Salaam HMI is a registered Trademark of HIILI AG. Schuman OEFIMIT COMO COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0159 DATE: 05/16/19 PROJECT NAME: TORRID - RACKING SITE ADDRESS: 17580 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 101(/ 6461 Building Division Public Works fl kl\A NW& Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) REVIEWER'S INITIALS: DATE: 05/21/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 06/18/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping PW Staff Initials: 12/18/2013 Espafiol Cont Search L&I Safety & Health Claims & Insurance ashington State Department of abor & industries A-% I nclux 1 I eli) My E.& I Workplace Rights Trades & Licensing SHILSHOLE DEVELOPMENT LLC Owner or tradesperson Principals GATLIN, ALBERT G, PARTNER/MEMBER YUKEVICH, MICHAEL A, PARTNER/MEMBER Doing business as SHILSHOLE DEVELOPMENT LLC WA UBI No, 602 310 597 2811 FAIRVIEW AVE E SUITE 1002 SEATTLE, WA 98102 206-777-2087 KING County Business type Limited Liability Company Governing persons ALBERT G GATLIN MICHAEL ANDREW YUKVICH; Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Not allowed to have apprentices. License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SHILSDL912K7 Effective --• expiration 05/27/2009— 06/11/2021 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 361188C $12,000.00 Received by L&I Effective date 05/27/2009 05/27/2009 Expiration date Until Canceled insurance Wesco Insurance Co $2,000,000.00 Policy no. WPP1063302 Received by L&I Effective date Help us improve 04/22/2019 05/27/2012 Expiration date 06/27/2020 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violatioAs during the previous 6 year period. Workers' comp Public Works Requirements Workplace safety and health tt't Washington State Dept. et Labe; ,ts. industries. Use ot this site is stio;ect to the ew of the stete ot Washington, Help us improve MAY I `T 9n1(I Y TER FIL ���,(.f�O�nP�� Permit No. I.F..r_sJ.i J — Plan review approval Is subject to errors ano omissions. Approval of construction documents does not allthnriZe the Violation of any adopted code or ordinance. Receipt of approved Field Copy and con I nowledgea: By: City of Tu.w„a e UILDING t11VISION SHEET NO. DESCRIPTION STRUCTURAL - STORAGE RACK SYSTEM SH-1 TITLE SHEET & ADDITIONAL INFORMATION SH-2 PARTIAL PLANS AND DETAIL SHEET - DRAWING INDEX REVISIONS No changes shall be mace to the scope Of WOrK Wltnout prior approval Of the, Tukwila Building Division. NOTE: Revisions wilt redulre a new plan submittal and may Include additional plan review. 1, SHELVING RACK LAYOUT PLANS HAVE BEEN PREPARED BY SHELVING RACK AND MOBILE TRACK SUPPLIER IN ACCORDANCE WITH STOCKROOM LAYOUT PREPARED BY THE ARCHITECT OF RECORD FOR THE TENANT IMPROVEMENT PROJECT. 2. TENANT'S G.C. IS REQUIRED TO FOLLOW INSTRUCTIONS NOTED ON ARCHITECTURAL TITLE SHEET PREPARED BY THE ARCHITECT OF RECORD FOR THE TENANT IMPROVEMENT PROJECT. 3. G.C. SHALL NOTIFY ARCHITECT/TENANT OF ANY DESIRED/NECESSARY MODIFICATIONS TO THE STOCKROOM LAYOUT SHOWN AND PREPARED BY THE ARCHITECT OF RECORD FOR THE TENANT IMPROVEMENT PROJECT: 4. G.C. IS REQUIRED TO COORDINATE ALL REQUIRED INSPECTIONS BY THE CITY OR THIRD PARTY INSPECTORS WHERE REQUIRED. S. G.C. SHALL CONTACT ECLIPSE ENGINEERING INC. IF ANY EXISTING STRUCTURAL CONDITIONS DIFFER FROM STATED ASSUMPTIONS GENERAL CONFORMANCE n,t�KIDL:FE slam • 0r.j3 to atSc 6fNORTH tr. * .:., „ , .,,.. ; , , y ,,,:: s,,,. . , _. _. _._.. _ .. , ._ _ . _.__. --_-_. ...._..,_ .. , ... __. __. A COMMERCIAL RETAIL TENANT IMPROVEMENT. THESE DRAWING 4 � S CONTAIN ONLY THE PARTIAL PLANS AND THE DETAILS THAT PERTAIN TO THE � o , " a ? ' • `� �? DETAILS OF THE PROPOSED SHELVING SYSTEMS AND PROPER ANCHORAGE OF THE STOCKROOWS FIXED AND MOBILE SHELVING RACK SYSTEMS. s n h 3 SEE ARCHITECTURAL PLANS FOR FULL EXTENT OF WORK. BUILDING CODES: 2015 IBC, ASCE 7-10, & 2012 RMI-MH16.1 VICINITY MAP: N.T.S SITE LOCATION: N.T.S SCOPE OF WORK 1. THE STORAGE RACKS SHALL BE INSTALLED SUCH THAT THE MAXIMUM OUT -OF -PLUMB MEASUREMENT SHALL j aeon s T- EGRESS PATH _ — _�- -� i NOT EXCEED 0.5" PER 10' 0" IN HEIGHT. RR a ------ HANaNd iop'- ear iND ROD- "-" HgraN ROD 2. THE OWNER SHALL MAINTAIN THE STRUCTURAL INTEGRITY BY ASSURING PROPER OPERATION, T _ e GE HOUSEKEEPING,AND MAINTENANCE OF THE RACK SYSTEM BY PROHIBITING OVERLOADING OF THE RACK - " - 1X p z6N'p SYSTEM AND REGULARLY INSPECTING FOR DAMAGE. I "` 3. UPON ANY VISIBLE DAMAGE, THE PERTINENT PORTIONS OF THE RACK SHALL BE UNLOADED IMMEDIATELY BY - THE USER AND THE DAMAGED PORTION SHALL BE ADEQUATELY REPAIRED OR REPLACED. i Tzi-. we I j l ' it I. r� I _ _ P.$ s _ _w 4. A D NOT FORKLIFT _ FIXED/MOBILE RETAIL SHELVES SHALL BE RESTOCKED BY HAND. O N USE A FT OR OTHER aTANDARD. FF4477RR�� � I MECHANIZED LOADER TO STOCK SHELVES. d..__ itJ r'41Vi1i4y1- 1 =s:1 tls istilh 1).Y ♦!M{• ii m 11 lt9ltnl+tfiP.. IDfr#NI t.S I I r I6ift�i a It,f'6ti l o II r - A91 _ NOTES OF CAUTION _ I M i +� EGRESS PATH �� �A €s dREri i 1 I I I SEPARATE PERMIT f t I 1 I I I - - RE UIRED FOR: IEWED FOR r �x II — — — — — — _-- 1 1 �` Mechanical �� JE COMPLIANCE I j L7-,,7 L�, Electrical APPROVED 1 a'-s III Lam! Plumbing BACK OF HOUSE ®_ ` `i i _ I _ . g STOCKROOM /� �� ail i i � Cityo T kwas fla ng ��Y 24 2Q1�9 ,1 I� - i -7s •uw. e I rsr I I i ;fr BUILDING DIVISION 1 z- i i Nam' City of Tukwila BUILDING DIVISION �. - l 2 i EGRESS PATH' '� I I (1 i LANDLORD TENANT ARCHITECT _ KIMCO REALTY TORRID LLC BRUCE M. CARLSON ARCHITECT, PLLC I , , , I� , I� I _ __ .. _ _, „ , _ _ _ 1 ([ I - 4065 FACTORIA SQUARE MALL SOUTHEAST 18305 EAST SAN JOSE AVENUE 800 WASHINGTON AVENUE NORTH, SUITE #208 !!! - ( - BELLEVUE, WASHINGTON 98006 CITY OF INDUSTRY, CALIFORNIA 91746 MINNEAPOLIS, MINNESOTA55401 TEL 425-373-3508 TEL 512-897-0176 TEL. 612-547-1300 CONTACT: TERRI MEZGEBU CONTACT- KENT KELLER CONTACT: BRUCE CARLSON I I I I I IE EMAIL- imezgeb"@kimcorealty.<om EMAIL: kkeller@hottopi-om EMAIL: torrid@cmarch.com 1 • i o - - - 5fill i d "W- s ; �I111 1 �� - nECEIVEn � o 6LG4YE R [ a ^" - t III 1 -11 ® 4.a Y l i� E�n l i l CITY �F 1'i�{1Vtl.�1 MAY 16 2019 tz 1.t' a STORAGE SHELVING ENGINEER MOBILE /FIXED SHELVING LAYOUT z 1 I (? ECLIPSE ENGINEERING J crrnNc • •� w- A L MOBILE MEDIA STORAGE SOLUTIONS i 376 SW BLUFF DRIVE, SUITE #8 PO BOX 177, 24 CENTER STREET _ _ � CENTER --�,. r -r r-�- �; t=,,, I BEND, OR 97701 PERMI T CCtU -,'go �, if i- PINE BUSH, NY 12566 - _--- c I'.� _ - _- -,— -• >�'.�..�.--..q .-.. -_ ... --..- _ �-�— - -" _..�,� .-. --n ^ ,-r --...� _ - -,r :� ' ' '-"^ -^^'^�-`-• ,•=�•�i-,'• t� .� TB 080 CONTACT: ROBERT VANCAMP CONTACT ESS CA ROBINSON EMAIL rvancomp@eeimtcom EMAIL jr@mobilemediastorage.com 10 STANDARDS!' F8 STANDARD t G�Olsq SPACE LOCATION: N.T.S PROJECT CONTACTS V rn an Z m tJ CL LU W 0 z� � v N z Z >7 Oc Lu LL Zob yaa PY 111 onMw r—I fV 4* N LU N v DO �H�rn t wu3: LL a V W Oa z LU �Ln PIn W `Q I._ J DCa0s U o V)D M ~ 0 ~ ''nn V Lu W Z W F LU J UJLij t0 W = T > W LU LU rF- F- < F- = U of ��// LL > 0 > z a Zz <(Dto ZU LU Q000 M Z `- DQ. () LU'm w W PROJECT #: 19-05-067 DATE: 5-09-2019 SHEET SHeal MAY 13 2019 GENERAL NOTES: 1) DESIGN OF STEEL STORAGE SHELVING ASSHOWN BYTHESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE 2012/151BC, ASCE 7-10, & ANSI/RMI-MH16.1(2012) 2) STEEL FOR ALL SHAPES IS Fy = 33 KSI (EXCEPT AS NOTED) 3) ALL ANCHORS ARE HILT] HUS-EZ (ESR-3027) OR APPROVED EQUAL (SPECIAL INSPECTION REQUIRED - REFERENCE TABLE BELOW) 4) (E) SLAB = MIN. 4" THICK CONCRETE SLAB -ON -GRADE w/ F'c = 2500 PSI AND MIN. 500 PSF SOIL BEARING S) ALL SHELVING INSTALLATIONS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE, EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD PER LEVEL 6) ALL SHELVING SHALL BE IN COMPLIANCE WITH THE CURRENT RMI STANDARDS 7) THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORED MATERIALAND THE CEILING SPRINKLER DEFLECTORS 8) THE SHELVING STOCKROOM WILL NOT BE OPEN TO THE PUBLIC 9) SHELVING UNIT'S MAXIMUM "OUT-OF-PLUMBNESS" SHALL BE 0.5 INCH IN 10 FT 10) STORAGE SHELVING CAPACITY =10 PSF PER LEVEL STATEMENT OF SPECIAL INSPECTION VERIFICATION AND INSPECTION PERIODIC _ HILT"" (ICC-ES ESR-3027) INSPECTED BY CONFIRM ANCHOR TYPE X 318* AX3'LONG- SECCTIONTION4.4, 5.2, TABLE 1 INSPECTOR CONFIRM CONCRETE X MINIMUM 2500 PSI COMPRESSIVE STRENGTH CONFIRM CONCRETE X 4" MINIMUM THICKNESS HOLE DIAMETER X 318' DIA X 2.314' LONG - SECTION 4.3, 4.4, FIGURE 4A INSPECTOR CLEAN OUT OF HOLE X BULB/BLOW OUT- INSPECTOR SECTION 4.3, 4.4 MINIMUMANCHORSPACING X 2.25' SECTION 4.4, 5,7, TABLE 2 INSPECTOR MINIMUM EDGE DISTANCE X SECTION 4.4,1'5" 5.7, TABLE 2 INSPECTOR ANCHOR EMBEDMENT X 2'S` SECTION 4.3, 4.4, 5.2, TABLE 2, 3 INSPECTOR TIGHTENING TORQUE X N 4.3, 4A, TIO40FT-LBS SEC TABLE 2 INSPECTOR Note: apectlon to be completed byy a 3rd party inspector X EARTHQUAKE DESIGN DATA: a) Seismic Importance Factor, IE =1 Risk Category II - Not Open to the Public b) Mapped Spectral Response Accelerations: Ss = 1.441 S1= 0.537 c) Site Class = D (Assumed) d) Spectral Response Coefficients: Sds = 0.960 SILL = 0.537 e) Seismic Design Category = D f) Basic Seismic -Force -Resisting System(s): Non -Building Structures, Steel Shelving g) Design Base Shear =110 lb h) Seismic Response Coefficient: Vt = 0,168 ]) Response Modification Factor: R = 4 j) Redundancy Factor: p =1.0 k) Analysis Procedure per ASCE 7-10, Section 15.5.1 �L. POST T—POST 14 GA. 0 14 GA. �,� UPRIGHT STEEL POSTS NOTE: THE SHELVING SHALL BE ATTACHED EXISTING WALL TO THE EXISTING WALL STUDS AND COVER CONCRETE SLAB. NO NEW STUDS OR -- STUD WALLS ARE REQUIRED. ISTING WOOD I Arm Flange for alignment STEEL WALL STUB Self Drilling #12 x 1" Screws - 1 into wheel channel — 16" D.C. MAX 2 screws from upright posts to carriage and 2 screws from anti -tip arm to carriageB�' Anti -Tip Arm PLAN VIEW — STE LL 3/8" HILTI HUS-EZ ANCHORS w/ #14x3" TEK SCREW AT 2-1/2" MINIMUM EMBEDMENT EACH WALL STUD HELF BEAM SPACED AT 24" O.C. MAX. -TYP• —REF. DETAIL 2 'e < ' a" . - •' •. • a` .;a SHELVING POST (STING STUD WALL e. •� ' SHELF BEAM IN. 1" EMBED. —REF. DETAIL 2 Q INTO STUD WALL a a •. .° a.' • e tv NOTES. ° • 4'' 1. CONTRACTOR SHALL FIELD VERIFY MINIMUM SIZE, SPACING, AND GUAGE OF EXISTNG WALL STUDS. 2. MINIMUM STEEL WALL STUD SIZE = 362S125-30 (3-5/8"x1-1/4"x20 GA.). 3. MNMUM WOOD WALL STUD SIZE = 2x4. ANTI —TIP TRACK f �� WALL ATTACHMENT DETAIL NOTE: NOTE: �1� N 1 /4"4 RIVET 14 GA. HIGH PROFILE SHELF BEAM PR 0"" ilJ R 1/4"0 RIVET Q ,5li6" 14 GA. LOW PROFILE SHELF BEAM SHELF BEAM CONNECTIONS NOTE: ANCHOR BOLTS SHALL BE LOCATED A MINIMUM OF 6" —POST FROM ANY CONCRETE T CONTROLIOINTS —POST x 1" SCR l f SCREW FASTEN W/ #14x1" STEN W/ #14x1" LONG TEK SCREW LONG TEK SCREW SHELVING LOAD ON SLAB = "T" POST COL. B.PL. "L POST COL. B.PL 100 PSF MAX (2) 3/8"0 ANCHOR BOLTS w/ 2-1/2" (1) 3/8"4 ANCHOR BOLT w/ 2-1/2- EMBEDMENT (SEE GENERAL NOTE #3) EMBEDMENT (SEE GENERAL NOTE #3) f � BASE PLATE AND SLAB DEl•AILS FIXED/MOBILE RETAIL SHELVES SHALL BE RESTOCKED BY HAND, DO NOT USE A SHELF CONFIGURATION (LENGTH, WIDTH, NUMBER OF SHELVES) VARIES PER UNIT: SCOPE O F WORK FORKLIFT OR OTHER MECHANIZED LOADER TO STOCK SHELVES. -REF. SHELVING CUTSHEETS AND FIXTURE PLAN REGULARLY INSPECT SHELVING FOR DAMAGE. IF DAMAGE IS FOUND, IMMEDIATELY ALL SHELVING TO BE WIRE GRID SHELVING ANCHORAGE OF FIXED AND MOBILE RETAIL SHELVING UNITS. THESE DRAWINGS UNLOAD THE AFFECTED AREA AND REPLACE OR REPAIR ANY DAMAGED COLUMNS, - BACK TO BACK UNITS, WHERE OCCURS, SHALL BE BOLTED TOGETHER WITH 1/4"0 CONTAIN ONLY THE PLANS AND DETAILS PERTAINING TO THE PROPER ANCHORAGE BEAMS, OR OTHER STRUCTURAL COMPONENTS BOLTS AT 24" O.C. ALONG THE LENGTH OF THE POST. OF THE BACK -OF -HOUSE FIXED AND MOBILE SHELVING RACK SYSTEMS. REFERENCE ARCHITECTURAL PLANS FOR FULL EXTENT OF WORK. THESE SHELVING UNITS ARE ENSURE THAT SHELVING IS NOT MODIFIED OR RE -ARRANGED IN A MANNER NOT NOT ACCESSIBLE TO THE GENERAL PUBLIC. WITHIN THE ORIGINAL DESIGN CONFIGURATIONS 36"-42 42" 42" 18"-24" 18" 78" 42" 18" 18" WALL —SUPPORTED FREE—STANDING FIXED SHELVING SIDE VIEWS MOBILE SHELVING SIDE VIEW FOR (2) RACKS BACK TO ATTACH RACK POSTS w/ 6 BOLTS AT 24" O.C. 1 FILE PARTIAL FLOOR PLAN & SHELVING RACK LAYOUT €iECFiVED CITY OF 1 L(KWILA MAY 16 2019 PERMIT CENTER NOTES/SYMBOLS STATIC UNIT MANUAL MOBILE UNIT c"-1 N U N M V W N Ln H v°'i rn t w U o O Uj CL Z Z Lij i— < I QQ Uj CC O U O D 0 66 � h O CL ✓ItVVEq FOR J Lu z 0 D W Lu J Uj T J W J..LU J Q Uj Q >LO W LLJ = C/i o z a rn Z Z Q U` LU ?OM ~ Lu 0 Ww� U in CO W D_ PROJECT #: 19-05-06 DATE: 5-09-2019 SHEET MAY 2 4 2019 ChY of Tukwila �, BUltD1NG D!V!SlON