Loading...
HomeMy WebLinkAboutPermit D19-0264 - BOEING #2-10 - FOUNDATIONS AND ANCHORS FOR VERTICAL STORAGE UNITBOEING #2-1O 1135 S WEBSTER ST BLDG 2-010 FINALED 06/10/2020 D19-0264 r Parcel No: ��^�xx ^�� Tukwila v�U~� v�o " ��n����na Department of Community Development 6]OUSovthcenterBoulevard, Sube#lOO Tukwila, Washington 9O188 Phono2O6-43z'367V Inspection Request Line: 306'43O'g3S0 Web site: http://www.TukwilaWA.gov 2185000005 Project Name: BOEING #2-10 DEVELOPMENT PERMIT Permit Number: D19'0264 Issue Date: 8/28/2019 Permit Expires On: 2/24/2020 Owner: Contact Person: Contractor: Name: License No: Lender: Address: 80E|NGCOMPANY THE POBOX 37O7M/[20-59PROPERTY MARTIN PROBST PO 8OX37U7; M/C:46-208,5EATTLE, WA, 98124 lO42l8URNM4MDRNVYSUITE 54' GIG HARBOR, WA, 98332 THE 8OE|NGCOMPANY POBOX 37O7; M/C46-ZO8'SE47TLE, VVA98D4 Phone: (206)852'4985 Phone: (253)853' 304 Expiration Date: 1/11/2020 DESCRIPTION OF WORK: INSTALL FOUNDATIONS AND ANCHORS TO SUPPORT A NEW VERTICAL STORAGE UNIT. Project Valuation: $35,000.00 Type ofFire Protection: Sprinklers: YES Fire Alarm: YES Type ofConstruction: |B Electrical Service Provided by: TUKWILA Fees Collected: $1371,41 Occupancy per IBC: 8 Water District: S[ATTLE,TUKvV|LA Sewer District: SE47TLE Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVAC2964§D: VVAState Energy Code: 2017 2017 2017 2015 Public Works Activities: [hanne|ioadon/Sthping: [vr6[ut/Access/Sidevva|k: Fire Loop Hydrant: Flood Control Zone: Hau|inK/Oveoizeioad: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: O Fill: O Number O No Permit Center Authorized Signature: Date: / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions oflaw and ordinances governing this work will becomplied with, whether specified herein nrnot. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local |aon regulating construction or the performance of work. | am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work bnot commenced within l8Odays for the date nfissuance, or|f the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: l: 'BUILDING PERMIT CONDITIONS' Z: Work shall heinstalled inaccordance withtheappnmedcunstmcdundocunnents,andanychangesmade during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site ofwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Tab|e17U53. S: The special inspections for steel elements ofbuildings and structures shall berequired. All welding shall be done byaWashington Association ofBuilding Official Certified welder. 6: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 7: When special inspection isrequired, either the owner orthe registered design professional innsponsib|p charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports tothe Building Official in atimely manner. 8: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall besubmitted tothe Building Official. The final inspection report shall beprepared bythe approved special inspection agency and shall be submitted to the Building Official prior to and as a condition nffinal inspection approval. 9: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the recommendations given in the soils report. Special inspection is required. 10: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 11: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 12: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 13: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 14: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 17: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 4037 SI-CAST-IN-PLACE 4046 SI'EPDXY/EXP CONC 4034 SI-METAL PLATE CONN 4028 SI-REINF STEEL -WELD CITY OF TUA r A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Per No. bl91 - 0 Project No. Date Application Accepted I 5- IC( Date Application Expires: '5" - (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 2-10 Bldg VSU Site Address: I ffat b16(01 3() King Co Assessor's Tax No.: 2185000005 8-123 tvlargirral try4, Tukwila) WA 8108 Suite Number: 2-10 Floor: 1 Tenant Name: The Boeing Company PROPERTY OWNER Name: The Boeing Company Address: PO Box 3707; M/C 46-208 City: Seattle State: WA Zip: 98124 CONTACT PERSON - person receiving all project communication Name; Martin Probst Address: PO Box 3707; M/C 46-208 City: Seattle State: WA Zip: 98124 Phone: (206) 852-4985 Fax: (253) 657-4659 Email: martin.r.probst@boeing.com GENERAL CONTRACTOR INFORMATION Company Name: Washington Patriot Address: 10421 Burnham Dr NW, Suite 5A CitY: Gig Harbor State: WA Zip: 98332 Phone: (253) 853-2304 Fax: Contr Reg No.: WASHIPC906BJ Exp Date: 01/11/2020 Tukwila Business License No.: 602 932 517 New Tenant: 1:1 Yes 21..No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Sitts & Hill Engineers Inc Engineer Name: Edmond Brown Address: 4815 Center Street City: Tacoma State: WA Zip: 98408 Phone: (253) 474-9449 Fax: Email: edb@sittshill.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: The Boeing Company Address: PO Box 3707; M/C 46-208 City: Seattle State: WA Zip: 98124 H:1Applicaiions \Forrns-Applications On Line \ 2011 ApplicationsWerrnit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMAI )41— 206-431-3670 Valuation of Project (contractor's bid price): $ 35,000 Existing Building Valuation: $ 41,819,500 Describe the scope of work (please provide detailed information): • Install foundations and anchors to support a new vertical storage unit. Mechanical, Electrical, and Plumbing permitted separately by others. Will there be new rack storage? 0 Yes J.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 388,992 649 0 0 IIIB B 2nd Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provtde the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes IZI No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0.. .... Automatic Fire Alarm El .....None 0 •••••..0ther (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:kApplicationsWorms-Applications On .Line \201 I: ApplicationsTemlit Application Revised - 13-9-11.doce Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFtMATION — 206-433-0179 Scope of Work (please provide detailed information): Install foundations and anchors to support a new vertical storage unit. others. echanical, Electrical, and Plumbing permitted separately by Call before you Dig: 811 Please refer to Public Works Bulletin # l for fees and estimate sheet. Water District 0 ...Tukwila 0...Water District #1 25 0 ...Water Availability Provided Sewer District El ...Tukwila 0 ...Sewer Use Certificate 0...Valley View 0...Sewer Availability Provided Highline .. • Renton 0 .. Renton 0.. Seattle Septic System: 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): o ...Civil Plans (Maximum Paper Size — 22" x 34") ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours El ...Right-of-way Use - No Disturbance o ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ...Total Cut 0 ...Total Fill 0 ...Sanitary Side Sewer 0 ...Cap or Remove Utilities 0 ...Frontage Improvements _Traffic Control ...Backflow Prevention - Fire Protection Irrigation Domestic Water cubic yards cubic yards o. 0. o. 0. O Geotechnical Report .. Maintenance Agreement(s) El ...Traffic Impact Analysis ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours o .. Right-of-way Use — Potential Disturbance .. ▪ Work in Flood Zone EJ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line 0 ...Permanent Water Meter Size... 0 ...Temporary Water Meter Size .. 0 ...Water Only Meter Size 0 ...Sewer Main Extension Public 0 0 ...Water Main Extension Public 0 .. • Grease Interceptor • Channelization .. • Trench Excavation 0 .. Utility Undergrounding WO # WO # WO # 0 ...Deduct Water Meter Size Private 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Apphcations On Line 2011 Applications\ Perinit Application Revised - 8-9-11 docx Revised August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UT RIZE AGENT: Signature: 114— Print Name: Martin Probst - The Boeing Company Mailing Address: PO Box 3707; M/C 46-208 Date: 08/15/2019 Day Telephone: (206) 852-4985 Seattle WA 98124 City State Zip HAApplications \Forms -Applications On Line1201 I Applications‘Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 . • ,..., . DESCRIPTIONS ,. .. r ACCOUNT QUANTITY • PAID PermitTRAK 4 $72.10 019-0264 Address: 1135 S WEBSTER ST BLDG 2-010 Apn: 2185000005 $72.10 Credit Card Fee $2.10 Credit Card Fee R000.369.908.00.00 0.00 $2.10 DEVELOPMENT $70.00 ADDITIONAL PLAN REVIEW '1 ;• TOTA i,FEES PAID BY RECEIPT: R19243 R000.345.830.00.00 1.00 N , ,. $70.00 $72.10 Date Paid: Monday, December 09, 2019 Paid By: MARTIN PROBST Pay Method: CREDIT CARD 010468 Printed: Monday, December 09, 2019 11:48 AM 1 of 1 SYSTEMS COTUKWILA ETKAKIT 6200 S0UTH[ENTER BLVD TUKWILA' W« 98188 206'4]]'1870 CITY OF TUKWILA 0817340000802374404500 Date: 12/09/2819 11:46:38 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: TRAN AMOUNT: $72,10 APPROVAL [D: 810468 KE[0KD #: 000 CLERK ID: frankie X {CARDHOLDER'S SIGNATURE} z AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MiERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $1,371.41 D19-0264 Address: 8123 E MARGINAL WAY S Unit2-10 Apn: 3324049002 $1,371.41 Credit Card Fee $39.94 Credit Card Fee R000. 69.908,00.00 0.00 $39.94 DEVELOPMENT $1,293.04 PERMIT FEE R000.322.100.00.00 0.00 $768.51 PLAN CHECK FEE R000.345,830.00.00 0.00 $499,53 WASHINGTON STATE SURCHARGE B640.237.114 0.00 .00 TECHNOLOGY FEE $38.43 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18342 R000.322.900.04.00 0.00 $38.43 $1,371.41 Date Paid: Thursday, August 15, 2019 Paid By: MARTIN PROBST Pay Method: CREDIT CARD 088172 Printed: Thursday, August 15, 2019 11:40 AM 1 of 1 0 C CO CITY OF TUKWILA 0017340800802374404500 Date: 08/15/20I9 11:39:42 Am CREDIT CARD SALE MASTERCARD CARD NUMBER: TRAN AMOUNT: $1,371.41 APPROVAL [D: 088172 RECORD #: 008 CLERK ID: kandace X {CARDHOLDER'S SIGNATUREJ I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy REVIEWED FOR CODE COMPLIANCE APPROVED DEC 05 2019 City of Tukwila BUILDING DIVISION REVISION NO.L SITTS & HILL ENGINEERS, INC. Professional Engineers & Planners CIVIL, STRUCTURAL AND SURVEYING RECEIVEn CITY OF TUKWILA NOV 15 2019 b 0210 2/PERMIT CENTER FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 2-10 TUKWILA, WA 98108 ZI___AFISKEZAW CALCULATIONS PREPARED FOR THE BOEING COMPANY POST OFFICE BOX 3707 SEATTLE, WA 98124 PREPARED BY Sitts & Hill Engineers, Inc. 4815 Center Street Tacoma, WA 98409 November 4, 2019 S & H Job Number: 18,391 SITTS & HILL ENGINEERS, INC. DESIGNED EMF DATE 11/4/2019 JOB 18,391 TACOMA, WASHINGTON (253) 474-9449 CHECKED AJB DATE 11/4/2019 IIM PROJECT FOUNDATIONS FOR VERTICAL STORAGE UNITS PAGE 1 CALCULATION INDEX BASIS DESIGN CRITERIA AND ASSUMPTIONS FOUNDATION AND ANCHORAGE ANALYSIS Column and Anchorage Loading 11-12 Foundation Analysis 13 - 21 Punching Shear 13 "" Flexural Strength 14 - 22 Bearing Capacity 23 - 25 M Anchorage Analysis 26 - 45 APPENDICES rig .r 2-4 5 -9 10-45 SAFE Model Report and Loading Diagrams Appendix A Kardex Remstar Documents Appendix B 0:\18300\18391 \Calculations\Structural118391-JPV.xlsm wii awl 2 BASIS FOR DESIGN SITTS & HILL ENGINEERS, INC. SITTS & HILL ENGINEERS, INC. DESIGNED EMF DATE 11/4/2019 JOB 18,391 NI TACOMA, WASHINGTON (253) 474-9449 CHECKED AJB DATE 11/4/2019 PROJECT FOUNDATIONS FOR VERTICAL STORAGE UNITS PAGE 3 VIM BASIS FOR DESIGN MI BUILDING CODE: 2015 Edition of the International Building Code with State of Washington and City of Tukwila amendments shall be used and supplemented with ASCE 7-10. MATERIALS CODES: Building Code Requirements for Structural Concrete, ACI 318-14. Specification for Structural Steel Buildings, ANSI/AISC 360-10. RISK CATEGORY: 11. 1111 SEISMIC IMPORTANCE: le = 1.0 per ASCE 7-10 Table 1.5-2. GRAVITY LOADS: Weight of VSU = 7,250 Ibf, per manufacturer. Weight of trays = 8,311 Ibf, per manufacturer. Weight of fully loaded VSU = 85,778 Ibf, per manufacturer. Weight of fully loaded tray = 1080 Ibf, per manufacturer. (2) Trays per shelf level. opi LATERAL LOAD CRITERIA: Seismic Site Class: D (assumed). Seismic Design Category: D. Iwo STRUCTURAL STEEL: ASTM A36 OR CONCRETE: Minimum compressive strength of proposed VSU foundation is 4,000psi. Minimum assumed compressive strength of the existing concrete slab on grade is 5,000psi. 11111 FOUNDATIONS: Assumed allowable soil bearing pressure = 1,500 psf. Assumed allowable soil bearing pressure under seismic loading = 2,000 psf.* • * using industry common 1/3 bearing pressure increase for transient loading Assumed modulus of subgrade reaction = 150 pci. n 0: \ 18300 \ 18391 \ Calculations \Structural\ 18391-JPV.xlsm SO75&HILL ENGINEERS, INC. rAcoMA,w«S*/worow (253)474-9449 PROJECT FOUNDATIONS FOR VERTICAL STORAGE UNITS SEISMIC DESIGN CRITERIA - SITE osoamso EW1F DATE 6/4/2019 /cm 18,391 CHECKED AJB DATE 6/4/2019 Address: 1135IVVE8STEKS[ Site Class: o (Assumed) ASCE 7-u0,SECTION 11.4: F�=1I0 6m,~55F,~1.5l6x1l0 S*o~ 1.516 5e=2/3 Sms= 2/3xIj16 Sm~1.O1l ABCE7'10 SECTION 215/ Risk Category: U ASCE 7'10,SECTION 21.6: Seismic Design Category: D (Table 11.4-1) (Equation 11.4-1) (Equation 11.4-3) Latitude; 47.5318 Longitude: -122.3151 S,~1.5lb 5,=[i579 (U5GS) F,=1.5O (Table11.4-2) Sw,~5IF,~U.579xl.5O (Equadon1l.4Z) Swz=O.D08 SDI =2 � Smz= 2/3x0.868 (Equation 11.4-4) SDI ~Os79 I�=1lN (Tab|e1.5-l) (Based on Tables 11.6-1 and 11.6-2) O^18300n8391mm1-Jpv.xlum 5 1 DESIGN CRITERIA AND ASSUMPTIONS Owl SITTS & HILL ENGINEERS, INC. • Ns • N s N s 0 0 Iwo 111 twi O N I O SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 6 CHECKED: AJB DATE: 08/09/2019 DESIGN CRITERIA AND ASSUMPTIONS: Seismic Classification per ASCE 7-10 The VSU drawings provided by Kardex Remstar do not clearly identify a lateral force resisting system. Although the load distribution provisions for steel storage racks defined in section 15.5.3 appear appropriate for the purposes of determing the operating weight and vertical force distribution of the structure, the definition of steel storage racks in section 11.2 does not allow us to logically classify the structure as a steel storage rack for determination of seismic response properties. The VSU's are most accurately characterized as nonbuilding structures not similar to buildings per chapter 15. However, the only lateral force resisting system in Table 15.4-2 that appears to be applicable to the VSU's are "All other self-supporting structures...not similar to buildings". Therefore, the seismic coefficients for this system are used in the design of the foundations and anchorage. Existing Concrete Slab on Grade Grid lines are spaced at 60' on center in the east -west direction and at 20' on center in the north -south direction. Control joints are present at each gridline, and an intermediate control joint is present between the columns in the east -west directions, bringing the spacing between control joints to 30' on center. Cracks were observed in the north -south direction at the middle of this 30' span at a number of locations. Therefore, the floor slab for the VSU foundation is modeled as a 20'x30' element with a shear transfer only joint at the middle of the 30' span. See the sketch below for a graphical depiction of the described slab conditions and approximate locations of the proposed VSU's. 20' 20' PROPOSED VSU LOCATIONS FLEXURAL CRACK CONTROL JOINT, TYPICAL Created with PTC Mathcad Express. See www.mathcad.com for more iiformation. — ri• SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 7 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 Analysis Procedure: As noted in the Scope of Work, our analysis does not include checking the structural adequacy of the superstructure of the VSUs. The weight of the structure, seismic base shear, and seismic overturning moment are used to compute shear, tension, and compression forces at the column and anchorage locations noted on the VSU drawings. These forces are applied to analyze the VSU foundations and anchorage. The software program SAFE, version 16.0.2, is used to model the proposed foundation and compute the demand punching shears, design the foundation reinforcing, and assess the soil bearing pressures. The the VSU anchorage is designed according to the provisions of ACI 318-14 Chapter 17. The overstrength factor, Ow is applied to the seismic forces used to design the anchors for shear loads, and the anchors are designed for a ductile failure mechanism in tension per ACI 318-14 17.2.3.4.3 (a). 4.0 Vertical Storage Unit (VSU) Dimensions ani Owl Supeering etread =dam a- 140 coal on boa fable iaxt 1 Xc Xt EMI a _ X = 5211.7 rim pox 201rret INA inj 1 Heat for floor ane.hoHna 0 se VII FiS51 Arercv tune E @two d taellreAte PIO Ain Me ii) 053 awn iti326 Created with PTC Mathcad Express. See www.mathcad.com for more iiformation. SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EM.F DATE: 08/09/2019 8 CHECKED: AJB DATE: 08/09/2019 B:= 109.45 in Width L := 120.98 in Length H=26.41 ft Height Ab := 8.07 in • 4.73 in = 38.2 in2 Bearing area per column n:=8 Number of columns X,:= 104.72 in Distance between compression centers, x-direction Xt := 94.49 in Distance between tension centers, x-direction d = distance between compressions and tension centers in the x-direction as calculated in the anchorage analysis Yi:= 28.88 in Y2 := 55.18 in Y3 := 28.88 in VSU Gravity Loads: We := 7250 lbf +8311 lbf =15561 lbf Weight of VSU and empty racks Wo:= 85778 lbf Maximum operating weight of VSU Wp := WO —We =70217 lbf Maximum storage load in VSU Wi:= 2 .1080 lbf =2160 lbf Maximum load per storage level in VSU VSU Seismic Loads per ASCE 7-10: Seismic Coefficients and Properties: ./,:= 1 R:=1.25 120:= 2 S Ds := 1.011 S DS C = 0.8088 Seismic Importance Factor per Table 1.5-2 Response Modification Factor per Table 15.4-2 Overstrength Factor per Table 15.4-2 Short-term design spectral response acceleration Seismic response coefficient per Eivation 12.8-2 Created with PTC Mathcad Express. See www.mathcad.com for more information. 1 1 1 a • SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units Seismic Base Shear and Distribution: JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 9 CHECKED: AJB DATE: 08/09/2019 The operating weight of the structure and the vertical distribution of seismic forces can reasonably be determined in a manner similar to the provisions provided by section 15.5.3 for steel storage racks. Two loading conditions must be considered when computing the operating weight for calculation of the seismic base shear per section 15.5.3.6: (a) Weight of racks plus every storage level loaded to 67% of its rated load capacity (b) Weight of racks plus highest storage level only loaded to 100°/0 of its rated load capacity The base shears corresponding to these requirements are: Va:=Cs• (We+ 0.67 Wp) =50636 lbf Condition A seismic base shear per Equation 12.8-1 Vb:=Cs• (We+Wi)= 14333 lbf Condition B seismic base shear per Equation 12.8-1 The distribution of the seismic base shear is performed in accordance with ASCE 7-10 Sections 15.5.3.7 and 12.8.3. The weight of the structure and racks is assumed to be evenly distributed across the height of the structure, and the storage weight is distributed according to section 15.5.3.6. The resulting overturning moments due to seismic loading for loading conditions A and B are as follows: Condition A: Loads evenly distributed across the height of the structure result in a center of action of seismic force at 2/3 of the height of the structure. Ma=Vaa • —2 H=891532 lbf • ft Condition A seismic overturning moment 3 Condition B: k := 1 Per Section 15.5.3.7 (c) W.Hk Cm := C„ := Wi•Hk +We 2 =0.217 Vertical distribution factor of top rack load per (H" Equation 12.8-12 2 )k wi•Hk +we•Hk mb:=vb• H Cm•H+,---ve • — 2 — 0.783 Vertical distribution factor of structure and racks per Equation 12.8-12 = 230390 lbf • ft Condition B seismic overturning moment Condition A loading controls. /1/0:=Ma= 891532 lbf • ft V:=Va=50636 lbf Created with PTC Mathcad Express. See www.mathcad.com for more information. FOUNDATION AND ANCHORAGE ANALYSIS SITTS & HILL ENGINEERS, INC. imr SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units FOUNDATION AND ANCHORAGE ANALYSIS: Column and Anchorage Loading: Dead and Seismic Shear Loads: PD:=-8— w° =10722 lbf CDPD = 40450 psf — Ab V v E:==6330 lbf JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 11 CHECKED: AJB DATE: 08/09/2019 Dead load per VSU column Dead load over bearing area per VSU column Seismic shear load per VSU column Seismic Axial Loading Analysis About Length Axis: d:=X, = 99.6 in 2 X —X, Mt, PE1:=-4 d=26852 lbf C --E1=101299 psf Ab Distance between compression and tension centers of VSU columns across length axis Seismic axial load per VSU column Seismic axial load over bearing area per VSU column Seismic Axial Loading Analysis About Length Axis (2 VSU's Tied TogetherAlong Length Axis): d := B fX,—Xt) (B—X,) 2 2 209 in B (B —X,) 2 2 M PE2:= ° 4 d =25587 lbf PE2 CE2:=—= 96528 psf Ab Distance between compression and tension centers of VSU columns across length axis Seismic axial load per VSU column Seismic axial load over bearing area per VSU column Seismic Axial Loading Analysis About Width Axis: /Y2)2 I2 I := 4 + 4 +Yi =15800 in2 Moment of inertia of VSU column group 2 2 about width axis \ 2 Mo. PE3:= 2 =18681 lbf Seismic axial load per interior VSU column Created with PTC Mathcad Express. See www.mathcad.com for more information. SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertic@l Storage Units CE3:=PE3 = 70475 psf Ab M o• PE4.= Y2 —+ =38236 lbf PE4 C E4=—= 144244 psf Ab JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 12 CHECKED: AJB DATE: 08/09/2019 Seismic axial load over bearing area per interior VSU column Seismic axial load per exterior VSU column Seismic axial load over bearing area per exterior VSU column Created with PTC Mathcad Express. See www.mathcad.com for more nformation. SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EIVF DATE: 08/09/2019 13 CHECKED: AJB DATE: 08/09/2019 Foundation Analysis: The proposed foundation was modeled according' to the design criteria and assumptions using the software program SAFE 2016, and dead and seismic loads were applied to the model as calculated above. The foundation was assessed for punching shear and flexural capacity using LRFD load combinations, and for bearing capacity using ASD load combinations. A SAFE model report and loading diagrams can be found in Appendix A, and graphical results for the flexural and bearing capacity checks can be found in their respective calculation sections. Punching Shear (ACI 318-14 Table 14.5.5.1): 4)=0.75 Strength reduction factor for shear per ACI 318-14 Table 21.2.1 c:= 4000 psi Compressive strength of concrete h:= 27 in Foundation thickness d := h — 3 —0.625.1.5=23.06 in Depth to reinforcement A:=1.0 Factor for normal -weight concrete 13 := 2.4.73 in =1.17 8.07 in Ratio of long to short side of load area of tied columns 1)0=2 • 0.07 + d) + (4.73 • 2+0= 127.31 in Punching shear perimeter as:= 40 Vn:= 4). ACI 318-14 Section 22.6.5.3 , (2+ a3 d ) • A • c) • b 0 • d b 0 •Vn= 557.08 kip 1000 =742.778 kip Nominal punching shear strength per ACI 318-14 Table 22.6.5.2 Design punching shear strength Maximum LRFD Vu:= 2 - ((1.2 + 0.2 Sa9) •PD-F max (PEi ,PE2IPE31PE4))= 106.54 kip demand punching shear (/).Vu>Vu . OK Created with PTC Mathcad Express. See www.mathcad.com for more information. SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EMF DATE: 11/04/2019 14 CHECKED: AJB DATE: 11/04/2019 Flexural Strength: Minimum shrinkage and temperature reinforcement is provided at the top and bottom of the slab per ACI 318-14 Table 7.6.1.1: A8mjnin2 := 0.0018 • h • 12=0.583 ft A := 0.44 in2 s := 8 in 12 in = 0.660 in2 As:=A#6• s ft As> Asmin .'. OK Minimum reinforcement per ACI 318-14 Table 7.6.1.1 Cross -sectional area of #6 reinforcing bar Spacing of reinforcement Area of steel provided per foot Reinforcing of #6 bars @ 8" is specified in the SAFE model, and the attached program output details the amount of reinforcing required above the specified reinforcement as well as the maximum and minimum moment intensity diagrams. Per the SAFE analysis, additional reinforcement is not required, and the foundation can adequately support the flexural loads imposed by the VSU's. so 1 Poi 1 1 1 1 nod Nei 1 Proposed Foundation 11/1/2019 1:24 PM : t 1tI ' --.!,--- -----Ii- 4 i, --"--1 .. i .i---- . -- '-i-:. ;1 r 4 i I I i ' I I ' + 4 1-- , _ "; 1 „,' , . 1. ; 1 1 - ii_ .:i , ,. ,. ;; ;1 i ; ,,, I -Li- _L-L- -1- --1 1 ' LLI i t ' i .,_j__ _ ._...._• .._.:. ... __ ....._.„.._,..,....__.HJ .__i . __ 1 4t 4r , . I ' „TH 41 —,_ 0.00 2 i __I ' ' ' _LI L ..4 __Li i s i , , • ....,.. . . . ! : i . ii. 1•!:,...,f i . . : ; ' lit ' 111. k i 1 i ' I. • ,1 1 : , ; • t ; ! i , I1 i_i; 1 1 --1—--/ Ejiii,tiL! ;H i • , i '• 1 1 .1 i 1 it di : iq 11-7 ,. '_i , ', - ' i i - ... • ',•- ,..-1.--1+— • , - i--'-'-"- " '-' t 1 t- ' ' 1 . ri--L...i_. 111_14_ i• J i 1,_ , .....! • ; 1 _..1____ ....L......1. _ _____L4.....1._1! ; . 1 F---r- 1 .1i..' 1 i 1 • J.....L ,{! .-i _ p. - Ir•-• I.. i . _I., -1-..i- :i - 11_1-', , ; 0.00 ... I i I 11 i ' I 1 I I : I : 1 . I _ 1 I 4_ , 1-0.00 0.0 0.00 0.00 ; 0 00 •1 . . I ;.; 0.00 0.00 I i 0.00 Top Rebar Intensity (Enveloping) [in2/ft] - Direction 1 - Additional to #6 @ 8 in 1 101 mod tr 11/1/2019 1:26 PM Proposed Foundation 1 i i 7 I 11 -tip _:::± -3.,_ —i --i._ I - It- - i t ll11 E r 1 !i r tL I l _:11�,L I I._ —I_ i4 _1 -- I k I u L i_ -, l� i _. i i I i, I i:i -1 l,LUt t t 1z t, t, I f. Lt t l i i L r- 4 1 x:k x i .t .t Est t. f i ! I-1 4 r _ .+ t � ._ . 1 1 4. .a IL f 1f 1 t t 1 i ,eJi.. _t:_ • fI ? I I. f;` ;; I I I f Bottom Rebar Intensity (Enveloping) [in2/ft] - Direction 1 - Additional to #6 @ 8 in 16 17 Proposed Foundation I ! • ; -ir- ; ; - • I T--Ti 7-- I , L Li : ---÷ - . - 1 , 4T- , 'L ill_ ..;i. ?J i 1 I ; 1 -1,- ., -- -ji ---L.... J 1 i ii i i 44 I I i. ; JF iIL _L li i i 1:-,-1. • .ii_l_ 1_ • -J-i-il + i'il-- I 14,-- -1-.1i--- 1-- .4 i— II- --I -zi....-,1 -- 1-i , . . . . - :--- -1- -I-- -',- '--- 7._... '- -7 - L,--!--!-----J-1 : 1 . • , , . 1...il______ CT- E11: li: 1-11i I ! 1:T. II ... — _ — ....Li ,......--E. :• , , . : . i_ ,_ .i+4 - -f -1- 4- - • : I + ' ' --_ . . „__. 1 . i', I I1I 1i_jI !; 1--ik -1--1E- I-11____--1_-_-1H÷ :---1 -:=1, . , . , IL._ ILL ..1 __ _ _ :71. , .., ...... '-...T..1:17:._,.-t, - ---. 1.1..:__ II 11 i . ; 1 . 3 i, .! '' - ! 1- 11 '''-• "t ; 11/1/2019 1:27 PM I -4-Ar- TI------- '+'--1+ -I- - t tmt - - - -4 - ---,--,- , 4.....-4- ; - . 1__-_-_. J. _ .. .4_ __ _i_ ,..4.__i_ i_.... _ _ ...4 _ , _ ___... _14_ ....__ - - 4- 0.00 _ i ' I : • Xi' i : , • ... iI- --- --1-- - ----* - 1- -T - r - - ---- -,--. - _ _ _ - ' .-- 1-- 1-0.00 - .10.00 0.60441"' 0.00 0.00 0.00 - - !.0.00 TgA)0 I ! ! 1. Top Rebar Intensity (Enveloping) [in2/ft] - Direction 2 - Additional to #6 @ 8 in • 1 1 1 kid ■ ■ r • ■ Proposed Foundation 11/1/2019 1:28 PM ! I I, 1 1 k III ..--r' -1 T =.ice tom,. I -� - I it ( (, ., _{ ._ , w_.. ��4 I� �T i L�-', y ! tip L .4 i I j a; _. fi .__ ;t �T ; _ _,', _ —1-' lwi_ . -,. . -; ; ,J I ; I, 1 I{ i } —i awml. u+ �u+«m� 1 E i 1 I I Bottom Rebar Intensity (Enveloping) [in2/ft] - Direction 2 - Additional to #6 @ 8 in 0 QO• 0.00 0.00 0_00 _ a0. 40 --0.0 • Proposed Foundation SAFE 2016 16.0.2 Slab Resultant Mmax Diagram - ((1.2+0.2Sds)D+EX+) [kip-ft/ft] 11/1/20191:31 PM kip - ft 19 110, is it] Proposed Foundation I� #E ..-- i-- —t— -- — 1— —; — 11/1/2019 1:42 PM 44.0 40.0 36.0 32.0 28.0 24.0 20.0 16.0 12.0 8.0 4.0 0.0 -4.0 -8.0 SAFE 2016 16.0.2 Slab Resultant Mmax Diagram - ((1.2+0.2Sds)D+EY-) [kip-ft/ft] kip - ft 20 fa • is u Proposed Foundation SAFE 2016 16.0.2 Slab Resultant Mmin Diagram - ((0.9-0.2Sds)D+EX-) [kip-ft/ft] 11/1/2019 1:37 PM kip - ft PEA Proposed Foundation SAFE 2016 16.0.2 Slab Resultant Mmin Diagram - ((1.2+0.2Sds)D+EY-) [kip-ft/ft] 11/1/2019 1:45 PM kip - ft 22 SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units Bearing Capacity: Dead Load: craumaze:= 1500 psf crD:= 827 psf C7 allowable -?- D • Dead + Seismic Load: ( allowable= 2000 psf 0-E:= 1702 psf CralLawable 0E OK •*. OK JOB: 18391 DESIGNED: EMF DATE: 11/04/2019 23 CHECKED: AJB DATE: 11/04/2019 Assumed allowable bearing pressure Maximum bearing pressure under dead loads per attached SAFE model output Assumed allowable bearing pressure Maximum bearing pressure under dead and seismic loads per attached SAFE model output Proposed Foundation SAFE 2016 16.0.2 Soil Pressure Diagram - (D) [Ib/ft2] 11/1/2019 1:14 PM kip - ft 24 i i I I i i i Proposed Foundation SAFE 2016 16.0.2 11/1/2019 1:18 PM MAXIMUM BEARING PRESSURE = 1702 psf -0.60 l i i -0.75 -0.90 Soil Pressure Diagram - (0.6D+0.7EY+) [Ib/ft2] kip - ft SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMIF DATE: 11/04/2019 26 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 11/04/2019 Anchorage Analysis: The VSU columns will be attached to steel embed plates anchored to the foundation with ASTM A706 rebar, welded to the embed plates and developed/hooked into the foundation per the sketches below: /5 AS711 A706 MAR. 7TP. I" THICK EMBED PLATE VSU COEOYN AND BASE ADNIER PER IRNUPLIURER DP. 3 58E5 AS ROICAIED PULE I"d"x0'-9" VSU - -- COLUMN RISE PULE RATE I"x5"x0'-9' VSU PFR MANUFACTURER COLUMN BASE PLATE CENTERED ON EMBED .+ PERUV�lFACIUflEA PLATECENTERED ON 003ED MTE I" 7NCX OECD PLATE VSU COEIRH AND RISE ADAPTER PER IAIRIEACTURER TIP. 3 SOES AS RBCAIEO S611 EXTERIOR VSU COLUMN AT EMBED PLATE( 5610 5611 /5 AST/ A706 MAR, TM S611 INTERIOR VSU COLUMN AT EMBED PLATE SCALE: 3' = 1 -0' S610L5611 P —max (P P 1 We + 0.67 W l kip u'— E1 E27PE37PE4 '+ 1.2+0.2 SDs) • 8 P I=49.21 We+0.67 W l Tue'=PE4 — (0.9 — 0.2 SDs) • 8 P = 32.78 kip Factored compression per column LRFD tension at exterior column - controls We+0.67 W Tui :=PE1— (0.9 — 0.2 SDS) • P l = 21.39 kip LRFD tension at interior column 8 We+0.67 W Te := 0.7 PE4 — (0.6 — 0.14 SDs) • 8 P = 23.18 kip ASD tension at exterior column We+0.67 W Ti := 0.7 PE1 — (0.6 — 0.14 SDS) • P / =15.21 kip ASD tension at interior column 8 J Vu:=VE=6.33 kip Factored shear per column fy:=60 ksi Yield strength of ASTM A706 Grade 60 rebar 0 := 0.75 Rebar strength reduction factor per ACI 318-14 Section 17.5.2.9 Rebar Tension Strength: max (T,,,e 7 Tui) = As_regd'— �•f 0.728 in2 y Rebar area required per column SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units As:= 0.31 in2 nreo reqd = 2.35 As n:=4 4)T:=4)•n•As • f y= 55.80 kip Tue OTn Rebar Shear Strength: (Wiz := 4, • n•As-f y= 55.80 kip =0.587 < 1.0 OK V?, - =0.113 < 1.0 .'. OK Combined Rebar Tension and Shear Check: T„ +(V u kcj)Tu (/)1/u = 0.701 JOB: 18391, DESIGNED: ENIF DATE: 11/04/2019 27 CHECKED: AJB DATE: 11/04/2019 Area of #5 bar Number of rebar required Number of rebar provided Design tensile strength of reinforcement Tension utilization Design tensile strength of reinforcement Shear Utilization 1.0 .*. OK Interaction check Interior VSU Column Welded Connection to Embed Plate (Conservatively Consider Only Two Sides Welded): b:=9 in d:= 5 in kip D:= 5 in e d d2 2 2 (b+d) =1.61 in 4 d•b+b2 oft= 6 b2 • (4 d+b) oth:= 6 (2 d+b) c, 4 b•d+d2 owt:= 6 43.50 in2 = 20.61 in2 =34.17 in2 Length of plate parallel to column length axis Length of plate parallel to column width axis Size of weld in sixteenths of an inch Eccentricity from center of VSU column base plate weld to center of embed plate in both axes Section modulus of weld about column length axis - top Section modulus of weld about column length axis - bottom Section modulus of weld about column width axis - top SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units awb:= d2 • (4 b = 7.43 in2 6 (2 b+d) 4 b + d) —6 b2 • d2 =156.35 in3 12 (b+d) Mu := Tui • e =34.38 kipin Tou:=1/. • e = 10.17 kip • in Mu Mu Mu + \Sit Sib Tui kip at= = 1.528 (b+d) in o-:=o-n,+0rt=6.947 k.ip in Otn:= 1.5.1.392 • D = 10.44 kip in JOB: 18391 DESIGNED: EMF DATE: 11/04/2019 28 CHECKED: AJB DATE: 11/04/2019 Section modulus of weld about column width axis - bottom Torsional modulus of weld Moment due to eccentricity in both axes Torsion due to eccentricity kip =5.419 Maximum weld axial stress due to moment in o- =0.665 < 1.0 .*. OK r :=v u =0.703 kip b in 'd e Tt := Tou• 2 =0.27 ALP kip 7:=Ts+rt 0.97 in in =1.3924)=6.96 kip ru := in Weld axial stress due to tension Weld axial stress Weld axial strength per AISC 360-10 Equation 8-2a Weld axial strength utilization Weld direct shear stress Weld torsional shear stress Weld shear stress Weld shear strength per AISC 360-10 Equation 8-2a =0.139 < 1.0 .*. OK Weld shear strength utilization =7.014 kip 0 := atan (1 =1.432 in Weld combined stress Weld load angle in radians SITTS & HILL ENGINEERS, INC. 1 • TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 11/04/2019 29 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 11/04/2019 1+ 0.5 sin (0) )• 1.392 •D=10.39 —kip Weld combined strength per AISC 1.5 in 360-10 Equation 8-2a —=0.675 1.0 .` . OK Weld combined strength utilization Exterior VSU Column Welded Connection to Embed Plate: b:=9 in Length of plate parallel to column length axis Length of plate parallel to column width axis d:=5 in D:= 5 —kiP in d d2 e:= =1.18 in 2 (1)+2 d) d2 • (2 b+d) 3 (b+d) (b + 2 d)3 12 m.:= =13.69 in2 d2 .(b+d)2 (b+ 2 d) =38.81 kip.in Tou:=17„. e= 7.50 kip -in Mu kip 17,,:= =2.835 in b+2 d) cr:= cr + kip =1.725 in —4. 60 kip in = 313.69 in3 cbt,:=1.5. 1.392 • D= 10.44 kip in = 0.437 Vv. kip r b in 1.0 . OK Size of weld in sixteenths of an inch Eccentricity from center of VSU column base plate weld to center of embed plate Section modulus of weld about bottom Torsional modulus of weld Moment due to eccentricity about length axis Torsion due to eccentricity Maximum weld axial stress due to moment Weld axial stress due to tension Weld axial stress Weld axial strength per AISC 360-10 Equation 8-2a Weld axial strength utilization Weld direct shear stress No SITTS & HILL ENGINEERS, INC. • TACOMA, WASHINGTON (253) 474-9449 N o O wer lad JOB: 18391 DESIGNED: EMF DATE: 11/04/2019 30 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 11/04/2019 (_d e) 2 kip Tt :=To. =0.09 Weld torsional shear stress in T:=7.8+-rt=0.79 kip Ovn,:= 1.392 -D=6.96 kiP in =0.114 < 1.0 OK (inn kip T-=2 := 4,628 in 0 :=atan(7)=1.399 4Yrn Weld shear stress Weld shear strength per AISC 360-10 Equation 8-2a Weld shear strength utilization Weld combined stress Weld load angle in radians 1.5 ki +0.5 • sin (0) )• 1.392 -D=10.363 -?Weld combined strength per AISC in 360-10 Equation 8-2a =0.447 < 1.0 .'. OK Weld combined strength utilization VSU Column Base Plate Design: The VSU column base plates are checked in flexure using plate elements in RISA-3D. Both interior and exterior column base plates are analyzed, and the welds to the embed plates are modeled as pinned supports. The ASD net tension loads, Te and Ti, are applied to the respective plate models as area loads over the VSU adapter plate profile. Per the attached RISA-3D analysis, the maximum plate flexural stress is 19.624 ksi which does not exceed the allowable stress of ASTM A36 steel of 36 ksi / 1.67 = 21.56 ksi. Therefore, 1" thick VSU column plate plates are adequate to support the VSU columns. 1 1 31 L BLC 1, ASO Tension Sitts & Hill Engineers E F v 1, 2019 at 3:33 PM 1 RISA-3D VSU Column Base Plates VSU Column Base and Embed Pia.. NI w .r No Slid aml w sod • owl • Company : Sitts & Hill Engineers : EMF ANEMETSCHEK COMPANY Model Name RISA Job Num Job Number Nov 1,2019 3:36 PM Checked By. 32 Hot Rolled Steel Properties ks Nu Theme (/1 Densitv(k/ft^3 Yiedlfks Finks Rt 1 A992 29000 11154 .3 .65 .49 50 1.1 65 1.1 2 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 58 1.2 3 A572 Gr.50 29000 11154 .3 .65 .49 50 1.1 65 1.1 4 A500 Gr.B RND 29000 11154 .3 .65 .527 42 1.4 58 1.3 5 A500 Gr.B Rect 29000 11154 .3 .65 .527 46 1.4 58 1.3 6 A53 Gr. B 29000 11154 .3 .65 .49 35 1.6 60 1.2 7 A1085 29000 11154 .3 .65 .49 50 1.4 65 1.3 Plate Primary Data A Joint B Joint C Joint D Joint Material Thickness in P2 N1 N5 N15 N14 qen Steel 1 ® 3 P3 N5 N6 N16 N15 •en Steel 1 P4 N6 N7 N17 N16 gen Steel 4 P5 N7 N8 N18 N17 •en Steel 5 P6 N8 N9 N19 N18 gen Steel 1 6 P7 N9 N10 N20 N19 «en Steel 1 7 P8 N10 N11 N21 N20 •en Steel 1 8 P9 N12 N22 N21 «-,« - - 1 '® 9 P10 N12 N13 N23 N22 gen Steel 10 P11 N13 N2 N24 N23 •en Steel 11 P12 N14 N15 N26 N25 gen Steel 1 12 P13 N15 N16 N27 N26 qen Steel 1 13 P14 N16 N17 N28 N27 gen Steel 1 14 P15 N17 N18 N29 N28 •en Steel 1 P16 N18 N19 N30 N29 16 P17 N19 N20 N31 N30 gen Steel 17 P18 N20 N21 N32 N31 •en Steel 19 P19 N33 gen Steel 1 19 P20 NM �® N34 «en Steel 1 20 P21 N24 N35 N34 • - 1 ® 22 P22 N26 N37 N36 • - 1 P23 N26 N27 N38 N37 gen Steel 23 P24 N27 N28 N39 N38 gen Steel 24 P25 N28 N29 N40 N39 gen Steel 25 P26 N29 N30 N41 N40 •en Steel 26 P27 N30 N42 N41 • 0 P28 N43 N42 • en Steel 28 P29 N33 N44 N43 •en Steel 29 P30 N33 N34 N45 N44 •• �"•���� qen Steel 30 P31 N34 N35 N46 N45 31 P32 N36 N37 N48 N47 32 P33 N37 N38 N49 N48 gen Steel 33 P34 N38 N39 N50 N49 •en Steel 34 P35 N39 N40 N51 N50 35 P36 N40 N41 N52 gen Steel 36 P37 N41 N42 N53 •en Steel 37 P38 N42 N43 N54 N53 gen Steel 1 38 P39 N43 N44 N55 N54 gen Steel 1 39 P40 N44 N45 N56 N55 qen Steel 1 RISA-3D Version 17.0.4[O:\...\...1Calculations\StructuraRVSU Column Base and Embed Plates.r3d] Page 1 1 1 1 1 Company I : Sitts & Hill Engineers e JDesignuermber : EMF : A NEMETSCHEK COMPANY Model Name : Nov 1, 2019 3:36 PM 33 Checked By Plate Primary Data (Continued) Label A Joint B Joint C Joint D Joint Material Thickness in 40 P41 N45 N46 N57 N56 qen Steel 1 41 P42 N47 N48 N59 N58 gen Steel 42 P43 N48 N49 N60 N59 gen Steel 1 43 P44 N49 N50 N61 N60 gen Ste& 1 44 P45 N50 N51 N62 N61 gen Steel 1 45 P46 N51 N52 N63 N62 qen Steel 1 46 P47 N52 N53 N64 N63 gen Steel 1 47 P48 N53 N54 N65 N64 qen Steet 1 48 P49 N54 N55 N66 N65 gen Steel 1 49 P50 N55 N56 N67 N66 gen Steel 1 50 P51 N56 N57 N68 N67 gen Steel 1 51 P52 N58 N59 N69 N3 gen Steel 1 52 P53 N59 N60 N70 N69 gen Steel1 53 P54 N60 N61 N71 N70 qen Steel 1 54 P55 N61 N62 N72 N71 gen Steel 1 55 P56 N62 N63 N73 N72 gen Steel 1 56 P57 N63 N64 N74 N73 gen Steel 1 57 P58 N64 N65 N75 N74 qen Steet 1 58 P59 N65 N66 N76 N75 gen Steel 1 59 P60 N66 N67 N77 N76 gen Steel 1 60 P61 N67 N68 N4 N77 gen Steel 1 61 P61A N37 N38 N49 N48 qen Steel 1 62 P62 N78 N82 N92 N91 gen Steel 1 63 P63 N82 N83 N93 N92 gen Steel 1 64 P64 N83 N84 N94 N93 qen Steel 1 65 P65 N84 N85 N95 N94 gen Steel 1 66 P66 N85 N86 N96 N95 gen Steel1 67 P67 N86 N87 N97 N96 gen Steel 1 68 P68 N87 N88 N98 N97 gen Steel 1 69 P69 N88 N89 N99 N98 qen Steel 1 70 P70 N89 N90 N100 N99 gen Steel 1 71 P71 N90 N79 N101 N100 gen Steel 1 72 P72 N91 N92 N103 N102 gen Steel 1 73 P73 N92 N93 N104 N103 qen Steel1 74 P74 N93 N94 N105 N104 gen Ste 1 75 P75 N94 N95 N106 N105 qen Steel 1 76 P76 N95 N96 N107 N106 qen Steel 1 77 P77 N96 N97 N108 N107 gen Steel 1 78 P78 N97 N98 N109 N108 qen Steel 1 79 P79 N98 N99 N110 N109 qen Steel 1 80 P80 N99 N100 N111 N110 gen Steel 1 81 P81 N100 N101 N112 N111 gen Steel 1 82 P82 N102 N103 N114 N113 gen Stee 1 83 P83 N103 N104 N115 N114 gen Steel 1 84 P84 N104 N105 N116 N115 gen Steel 1 85 P85 N105 N106 N117 N116 gen Steel 1 86 P86 N106 N107 N118 N117 gen Steel 1 87 P87 N107 N108 N119 N118 gen Steel 1 88 P88 N108 N109 N120 N119 qen Steel 1 89 P89 N109 N110 N121 N120 gen Steel 1 90 P90 N110 N111 N122 N121 qen Steel 1 91 P91 N111 N112 N123 N122 qen Steel 1 RISA-3D Version 17.0.4 [0: \... \Calculations\Struc a VSU Column Base and Embed Pia Page 2 • N EI • w it 111 • MI mei II Company : Sitts & Hill Engineers I RISA jDesruernrber : EMF A NEMETSCHEK COMPANY Model Name Nov 1,2019 3:36 PM 34 Checked By Plate Primary Data (Continued) Label A Joint B Joint C Joint D Joint Malerial ckn 92 P92 N113 N114 N125 N124 gen Steel 93 P93 N115 N116 N127 N126 gen Steel 94 P94 N116 N117 N128 N127 gen Steel 95 P95 N117 N118 N129 N128 gen Steel 1 96 P96 N118 N119 N130 N129 gen Steel 1 97 P97 N119 N120 N131 N130 gen Steel 1 96 P98 N120 N121 N132 N131 gen Steel 9 P99 N121 N122 N133 N132 qen Steel 1 100 P100 N122 N123 N134 N133 gen Steel 1 101 P101 N124 N125 N136 N135 gen Steel 1 102 P102 N125 N126 N137 N136 gen Steel 103 P103 N126 N127 N138 N137 gen Steel 104 P104 N127 N128 N139 N138 gen Steel 1 105 P105 N128 N129 N140 N139 qen Steel 1 106 P106 N129 N130 N141 N140 gen Steel 1 107 P107 N130 N131 N142 N141 gen Steel 108 P108 N131 N132 N143 N142 gen Steel 1 109 P109 N132 N133 N144 N143 gen Steel 1 110 P110 N133 N134 N145 N144 gen Steel 111 P111 N135 N136 N146 N80 gen Steel 112 P112 N136 N137 N147 N146 gen Steel 1 1 3 P1 3 N137 N138 N148 N147 gen Steel 1 1 4 P114 N138 N139 N149 N148 gen Steel 1 115 P115 N139 N140 N150 N149 gen Steel 1 116 P116 N140 N141 N151 N150 gen Steel 1 117 P117 N141 N142 N152 N151 gen Steel 118 P118 N142 N143 N153 N152 gen Steel 1 1 9 P119 N143 N144 N154 N153 gen Steel 120 P120 N144 N145 N81 N154 qen Steel 121 P121 N114 N115 N126 N125 gen Steel1 Plate Surface Loads (BLC 1 : ASD Tension) Plate Label Direction MaanitudeFksi 1 P20 Y .966 2 P30 Y .966 3 P40 Y .966 4 P50 Y .966 5 P19 Y .966 6 P39 Y .966 7 P29 Y .966 8 P49 Y .966 9 P18 Y .966 10 P38 Y .966 11 P28 Y .966 12 P48 Y .966 13 P17 Y .966 14 P27 Y .966 15 P37 Y .966 16 P47 Y .966 17 P16 Y .966 RISA-3D Version 17.0.4 [0:1...1...\Calculations\StructuraIWSU Column Base and Embed Plates.r3d] Page 3 MEI NM 0 • red 0 0 0 awl 0 Goa 0 Company : Sitts & Hill Engineers : EMF IIIRISA jDesignumerber A NEMET$CHEK COMPANY Model Name Nov 1, 2019 3:36 PM 35 Checked By Plate Surface Loads (BLC 1 : ASD Tension) (Continued) Plate Label Direction Ma nitude ksi 18 P26 Y .966 19 P36 Y .966 20 P46 Y .966 21 P15 Y .966 22 P25 Y .966 23 P35 Y .966 24 P45 Y .966 25 P14 Y .966 26 P24 Y .966 27 P34 Y .966 28 P44 Y .966 29 P13 Y .966 30 P23 Y .966 31 P43 Y .966 32 P61A Y .966 33 P80 Y .634 34 P90 Y .634 35 P99 Y .634 36 P109 Y .634 37 P79 Y .634 38 P89 Y .634 39 P98 Y .634 40 P108 Y .634 41 P78 Y .634 42 P88 Y .634 43 P97 Y .634 44 P107 Y .634 45 P77 Y .634 46 P87 Y .634 47 P96 Y .634 48 P106 Y .634 49 P76 Y .634 50 P86 Y .634 51 P95 Y .634 52 P105 Y .634 53 P75 Y .634 54 P85 Y .634 55 P94 Y .634 56 P104 Y .634 57 P74 Y .634 58 P84 Y .634 59 P93 Y .634 60 P103 Y .634 61 P73 Y .634 62 P83 Y .634 63 P121 Y .634 64 P102 Y .634 RISA-3D Version 17.0.4 [0: \...\Calculations\Structuraf\VSU Column Base and Embed Plates.r3d] Page 4 In IIIRISA so Com�my � 8�s &M0Eng�ensdD Don�me, � EMF �bNum�v w�u�Nmma ^wcwrmo*muom�w, 0 him OP w No to MR go h" Iw mw w am a am wo 2.0 Nov 1.2018 3:36FM Checked By 36 Bask Load Cases 8uCDeonhptkm ASD Tension Cateqor 64 oad Combinations Description ASD Tension S- P- S- 8- Fac- BLC Fac' Bu: Feu.. BLCFan.8- pmc.B- Fan.B- pac..B- Fec.8- poc..B.' Fac.. Yes Y 1 Plate Principal Stresses (By Combinadon) LC Plate Label Von Misesfks 1 1 P60 T 15.664 '6.348 11.006 706 19i624 2 B 6.348 -15.864 11.006 2337 19.024 3 1 P43 T 15.269 '8783 11.026 2.354 1Ei563 4 B 6.783 '15.269 11.026 .783 19.563 P7 T 20.46 1.988 9231 .049 19.638 0 8 '1.988 -20.46 9231 1.62 18.538 7 PG T 28.341 1.975 9.183 `049 19.429 B 1 B -1.975 _20.341 0.183 1.521 19.429 8 P8 T 10.441 1.513 8.964 .15 1&731 10 = 12 1 8 '1.513 49.441 8.864 1.72 18.731 P5 19.108 1.47 8.810 `151 18.417 B 4.47 49.108 8.818 1/42 18.417 13 1 P40 T 16.250 -3.139 9.699 723 18.035 14 B 3.139 '16.259 9.699 2'284 18.035 15 1 P100 T 6.344 43.971 10.157 .402 18.002 16 B 13.971 -6.344 10-157 1.073 18.002 17 1 P44 T 17.335 -1.179 9.257 -.762 17.953 18 B 1.179 -17.336 ` 9.257 .BOg 17-953 18 1 P18 T 19.387 4.841 7.273 .278 17477 -4.841 '19.387 7.273 1.849 17.477 10.68 6.255 6.713 .098 17.417 B -8.255 '19.68 6.713 1.689 17.417 23 1 P16 T 10.602 6.197 8.703 -.089 17`354 24 B '6.197 '19.602 6J03 1472 17.354 25 1 P19 T 18.343 2.237 8,053 .424 17.333 26 B -2.237 -18.343 8.053 1.885 17.333 M= P15 19.027 4.655 7.186 `279 17.170 -4.655 -19.037 7.188 1.293 17'179 17.180 487 8.351 .256 16.95 `487 -17.188 8.351 1,827 16.95 P14 7' 17.821 2.038 7.892 `429 16.895 Mi 35 1 P80 8 -2.038 '17.821 7.892 1,142 18.BS5 N T 16.122 '1.389 8.756 .852 16.859 P108 1.389 11.057 '16.122 8.756 2.223 16859 '8.313 9.685 .647 16,831 36 B 8.313 '11.057 9.685 2.217 16831 37 1 P20 T 15.882 4.058 877 .558 16773 38 B 1.658 -15.882 877 2.129 16.773 39 1 P13 T 15.651 '1.803 8J27 `560 18,626 40 B 1.803 '15.651 8727 1.006 16,626 MR R|SA-3DVersion 1T]].4 [Oi'\'VCalou|aUons\SbudunaKVSUColu n Base and Embed Plates.r3d] Page 5 IN m� Corn pan y Sims & Hill Engineers Dm��mer � EMp IIIRISAjubNvm�n Model Name 0 No w am IN In OR low a wd ow OR MW Nov 1.20UB 37 ��PM Checked By. Plate Principal Stresses (By C Loc T�M�� mm�� Von Mises[ks 41 � 1 P4 T `� 16774 449 8162 `282 16.554 42 B -.449 ,16.774 8.162 1'309 16554 43 1 p29 T 17.892 3'482 7.205 .558 1648 44 B '3,482 ~17.892 7.205 2.128 1643 8.004 -.087 16.348 4-R B 1.882 -15.328 8.604 .884 16.349 47 1 p34 T 17.054 1.803 7.625 `646 18.228 48 8 -1.803 -17.054 7.635 .925 16.228 49 1 P39 T 17.11 2.116 7.497 .08 18.157 50 B '2.110 -17.11 7.497 2.251 18-157 51 1 P49 T 15.286 -1.405 8.345 757 16.035 52 B 1.405 -15.286 8.345 2.328 16,035 63 1 P24 T 17.021 2.508 7.258 -.561 16.915 54 B -2.508 '17.021 7256 1.01 15.916 55 1 P42 T 10.012 '8.286 8.154 '.775 15.078 58 B 8.286 -10.012 9.164 J95 15.878 57 1 P28 T 18.056 7.199 5.429 .429 15.744 58 B -7.199 -18.066 5.429 1.907 15.744 59 1 P25 T 17.849 7.026 6.412 -.423 15.574 GD B '7.825 -17.849 5.412 1.148 15.574 61 1 p110 T 8.28 -0.572 8.926 .659 15.474 62 B 9.572 '8.28 9.926 2.23 15.474 63 1 P51 T 10.401 -7.381 8.881 771 15,457 64 B 7.381 -18.401 8.081 2.342 15.457 65 1 P102 T 11.72 '5.046 8.882 `764 15.342 GG B 5.645 -11.73 8.682 .807 15.342 67 1 P99 T 10.584 '6.GG5 8724 .427 15.225 68 B 6.865 '10.684 8.724 1.998 15.225 69 1 P28 T 17.498 9.4 4.849 -.184 115.168 70 8 '9.4 -17.498 4.049 1.387 15.168 71 1 P27 T 17.486 9.509 3.988 .174 16.183 72 B '8.508 -17.486 3.988 1.745 15.163 73 1 P10 T 14.353 -1.206 778 .396 14.982 74 B 1.208 -14.353 7.78 1.967 14.892 75 1 P3 T 14.094 '1.294 7.694 -.404 14.784 76 B 1.294 -14.094 7.694 1.186 14.784 77 1 PGO T %081 -6.5 8.29 J75 14.47 78 B 6.5 -10.081 8.29 2348 14.47 79 1 P121 T 12.184 -3.597 7.895 `726 14,335 80 B 3.597 -12.104 7.895 .844 14.335 81 1 p53 T 8.959 '0.418 8.188 '.78 14.292 82 8 6418 -9.058 8.188 791 14.292 83 1 P35 T 16.358 6.373 84 B -6.373 -16,358 4,993 .082 14.281 85 1 P38 T 18.254 6.478 4.888 .611 14.173 88 B -6.478 -16.264 4.888 2.182 14.173 87 1 P73 T 12.148 '2.636 7.392 `597 13.658 88 B 2.836 -12.148 7.392 '974 13.858 89 1 968 T 14.078 .891 6.594 `15 13.655 DO B -.891 -14.078 6.594 1.421 13,655 91 1 P83 T 12.222 -2.401 7.356 `67 13.639 82 B 2.491 '12.222 7.356 801 13.639 w R|SA'31DVansion 17]3.4 [Oi'\'VCalcu|oUons\GbucturmKVSU Column Base and Embed Platee.r3d] Page OR ow IN M IN hod IN MW w No OR OR ow N aw a No 0 aw 0 0 In, low Com�my � �uo&MNEng�aem Dro�me � EMF 111RISAjo�Num�x ' ^wo^,TSce'co"pANwbd�Nume, Nov 1.201g 3:36pM 38 Checked By Tau Maxf ksil Arniefmu Von Misesfks 93 P74 T 13.6 .079 678 `492 13.561 94 B -.079 '13.6 6.76 1]379 13.561 85 P33 11.631 -3.139 7.385 '.723 13.478 0G 3.139 -11.831 7.385 .848 13.478 87 P61A N 11.031 -3.138 7385 `723 13.478 98 3.130 '11.831 7.385 .848 13.478 SS P91 T 3.817 '11.177 7.397 `054 13.358 100 B, 11.177 '3.817 7.397 1.517 13.358 101 P67 T 13.81 .987 0.412 -.077 13.344 102 B `987 -13.81 6.412 1484 18.344 103 P65 T 13.555 458 6.648 `234 13'332 104 B, `458 '13.655 6.548 1337 13,332 105 P32 T 10.064 '5.027 7.545_ -.75 13.369 106 B 5.027 -10.064 7.545 .82 13.309 107 P41 10.152 -4.914 7.533 77 13.308 108 B 4.814 '10.152 7.533 2.341 13.308 109 P75 T 14.103 1.892 6.106 -.384 13.258 110 B '1.882 -14.103 8.106 1.188 13.258 111 P23 T 10.946 -3744 7.345 -.735 13.222 112 B 3744 '10.946 7.345 .836 13.222 113 P84 T 13.31 773 6.268 `592 12.941 114 B '.773 -13.31 6.268 .978 12.941 115 P38 14.531 9.763 2.384 `381 12.829 116 '9.763 -14.531 2.384 1.179 12.828 117 1 P37 T 14.429 0.899 2.265 367 12.781 118 B -9.899 -14.429 2.265 1.838 12.781 119 1 P78 T 14.006 2.977 5,515 `259 12.78 120 B '2.977 '14.006 6.515 1.312 12.78 121 1 P93 T 12.695 ',074 8.385 -.684 12.733 '12.695 6.385 .887 '3.283 0.838 `75 12.68 124 E B, 2.283 -11.394 8.838 .82 12.68 3.035 5.312 `741 12.422 -18.058 5.312 .83 12.422 M 1 P64 T 12210 `345 6.282 -.329 12.305 -12.219 6.282 1.242 12.395 -6.328 7.079 736 12.283 130 6.328 -7829 7.079 2.306 12.283 .757 5.836 -.025 12.269 8 -12.63 5.936 1.546 12.289 133 P48 T 13.468 3.085 5.191 747 12.221 134 B -3.085 -13.468 5.181 3.318 12'221 135 P77 T 13.464 3.103 5.151 -.124 12.194 136 B '3.163 -13.464 5.151 1.447 12.194 137 P85 T 13.343 3.213 5,065 `496 12.062 138 B -3213 '13.343 5D65 1,075 12.002 138 P101 T 7.832 '5.967 6.9 -.788 11.987 140 B 5.907 -7.832 6.9 803 11.987 141 P108 T 10.155 -2.745 6.45 .612 11.T7 142 8 2.745 -10.155 6.45 2.182 11.77 143 P31 T 9.421 '3767 6.594 .734 11.785 144 B 3.787 '9421 6.594 2.385 11.765 no RISA-3D Version 17.0.4 [0:\...\...\Calculations\StructurahVSU Column Base and Embed Plates.r3d] Page 7 w mm Corn pan y Sitts &M0Engkneers Des igmm EMF = IIIRISA�bNum�n ^w,wETsxcvnoMPA�om�wamo~' ' 0 wo ow MW 04 in I" a a 10i so no 0 wd ` "M w No OR No m� OR amd IN Md a am Nov 1.20U9 3:3OPW ]9 Checked By Plate Principal Stresses (By Combinadon) (Confinueco Plate Label boc SiqmalUmi'l Siqma2fks Tau Maxfksi Anqlefrad Von Misesfks 145 P21 T 9.301 -3J29 6.615 .688 11.623 146 B 3729 -8301 6.515 2.259 11.623 147 P63 10.686 -1.637 6.162 `45 11.592 148 N 1'637 40.686 6.162 1.12 11-592 149 P12 T 9.208 '3.784 6.496 `703 11.574 150 B 3.784 -9.208 6.498 .868 11.574 151 P90 8.81 -4.235 6.522 .123 11.528 152 N 4.235 -8.81 6'523 1.693 11.528 153 P78 T 13.420 2.383 5.031 -.014 11.429 154 B `3363 -12.436 5.031 1.557 11.429 155 P61 8.744 -0.380 8.555 .779 11.355 156 6.366 ~6.744 8.555 2.349 11.355 157 P1 12 T 7.574 '5.289 6432 -.776 11.190 158 B 5.289 '7.574 6432 .795 11.199 158 P86 T 12.74 4.773 3.983 -.338 11.148 100 B -4773 42.74 3.983 1.231 11.148 161 P52 T 6.519 -8.346 6.432 `775 11.142 182 B 6.346 -8.519 6.432 .785 11.143 163 P54 T 9'404 '2.885 8.135 -.753 11.117 164 B 2.865 '9.404 6.135 .818 11.117 165 P59 T 8.317 -2.916 6.117 737 11.067 166 B 2.916 '9.317 6.117 2.308 11.067 167 P94 12-068 2.795 4.637 `62 10.942 108 -2.705 42.088 4.637 .951 10.842 169 P98 10.417 -.437 5'437 .403 10.642 170 B .437 '10.417 5.427 1.98 10.642 171 P92 T 7.733 -4.343 6.038 -.768 18.594 172 B 4.343 -7.733 6.038 .803 10.594 173 P87 T 12.074 5.01 3'532 `103 10.507 174 B -5D1 '12.074 3.532 1.482 10.507 176 P89 T 10.579 .827 4.976 .192 10.28 176 B -.627 '10.578 4.976 1.783 10.28 177 P79 T 10.551 .647 4.952 .023 10.243 178 8 `647 -10.551 4.952 1.593 10.243 179 P88 T 11.531 3.509 3.971 .097 10.221 180 B '3.589 -11.531 3.971 1.668 10.231 181 P69 T 10.186 .236 4.975 `014 10.07 182 B -.236 40.186 4.976 1.557 10.07 183 1 P72 T 7.428 '3.643 5.535 -.705 9.772 1841 3.643 -7.428 5.535 .866 Q772 185 10.073 .787 4.643 `727 9.703 186 -.787 -10.073 4'643 .843 9703 187 P82 '3.639 5.486 -.739 9.68 188 B 3.639 -7.333 5.486 .832 9.88 109 P120 5.149 '5.958 5.553 746 9827 190 N 5.058 -5.149 5.553 2.316 9'627 191 1 P48 T 10.755 7.012 1.871 `705 9.456 192 B -7.012 '10.755 1.871 .865 8.456 193 P47 10.602 7.115 1.743 .691 9.359 194 -7.115 -10.602 1.743 2.261 9.359 105 P86 10.745 4.996 2.876 `459 9313 196 B -4.996 '10.745 2.875 1.111 9.313 IN �� RISA-3D Version 17.0.4 [0:\...\...\Calculabons\StructuraRVSU Column Base and Embed Plates.r3d] Page 8 IN Company Sitts &MNEngineers Designer EMF bw ������ - -- - J���b� � ------� - Model Name ' 0 immi IN n 0 no 0 OR wd so k1w no i� Nov 1.20U8 3:36FM 40 Checked By Plate Principal Stresses (By C(Continueco Tau Max[ksil Anale[rad Von Misesfksi 197 1 P11 T 7.815 -2479 5`147 .582 9.385 198 B 2479 -7.815 5.147 2.133 9305 199 1 P2 T 7.758 -2.504 5.132 `566 9.368 200 B 2J504 -7.759 5.132 1.005 9.260 201 1 P97 T 10.181 3.386 3.392 .319 8.978 202 8 -3.386 -10.181 3'392 1.89 8.978 203 1 P118 T 8.947 -2.964 4.956 .066 8.811 204 B 2.984 -6.947 4.956 2.237 8.811 205 1 P113 T 7.041 -2.775 4.808 -.730 8.766 206 B 2.775 -7.041 4.908 .833 8.765 207 1 P111 T 5.001 -4.064 5.012 -.778 8.682 208 B 4.964 '5.061 5.012 783 8.682 209 1 PgG T 9.801 5.555 2.123 -.024 8.513 210 B -5,655 -9.801 2.123 1.546 8.513 211 1 P80 T 7]348 -1.787 4'418 -.083 8.081 212 B 1.707 '7.048 4.418 1488 8.081 213 1 P107 T 8.556 1.508 3.524 .574 781 214 O -1.508 -8.556 3.524 2.146 7.81 215 1 P55 T 7.883 -.012 3.948 -.71 7.888 218 B .012 -7.883 3.848 .881 7.889 217 1 p62 T 6.177 -2.358 4.367 -.595 7.634 218 B 2.358 -6.177 4.267 .975 7.634 219 1 P58 T 7.816 -.027 3.821 703 7.629 220 B .027 -7.618 3.821 2.274 7.629 221 1 P1O5 T 8.003 3.529 2.237 -.634 6.947 223 B -3.529 -8.003 2.237 .937 6.047 223 1 P70 T 6.234 -.236 3.235 -.092 6.355 224 B .236 -6.234 3.235 1.479 6.355 225 1 P114 T 5.838 -.749 3.294 -.701 6.247 226 B .749 ~5.838 3.284 .869 8.247 227 1 P106 T 8.722 4.584 1.069 .244 5.949 228 B -4.584 -6.732 1.069 1.814 E949 229 1 P81 T 3.203 -3.356 3.270 -.207 5.68 230 B 3.366 -3.203 3.279 1.274 5.68 231 1 P117 T 5.365 -.28 2.823 .608 5.511 232 B .28 15.385 3.823 2.178 5.511 233 1 P56 T 5.511 2.808 1451 -.564 4.775 234 B '2.608 -5.511 1,451 1.007 4.775 235 1 P57 T 545 2'657 1.396 .558 472 236 B -2.657 '5.45 1.396 2.129 4.72 237 1 P115 T 4.274 1.181 1.546 -.576 3.823 238 B -1.181 -4.274 1.546 .895 3.823 239 1 P116 T 3.881 1.786 .948 .315 3.188 240 B -1.788 '3.681 .948 1.886 3.188 241 1 P71 T 2.018 -.608 1.358 -.227 2.443 242 B .698 '2.018 1.358 1.344 2443 0 RISA-3OVersion 17�.4 [0,\'\'\Calcu|ations\Qboctum��UColumn Base and Embed Flates.r3d] Page 1 • P.= 49.21 kip :=P • e = 4• 86 ft •kip tt_p u SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 11/04/2019 41 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 11/04/2019 Rebar Connection to Embed Plate: The ASTM A706 #5 rebar are welded with 5/16" flare bevel welds on each side of the rebar over their entire length. The strength of this weld is adequate by inspection, noting that the welded connection of the VSU adapter plate to the embed plate is more than strong enough to withstand the design loads. Embed Plate Design: An approxmate embed plate analysis is performed through a RISAConnection base plate analyses. The rebar are welded continuously to the plate, so the base plate analysis with discrete anchors at the vertical rebar locations produces a conservative design. The design loads applied in the RISAConnection model are specified below, and RISAConnection design results are attached. A 1" thick embed plate is found to be adequate to support the VSU columns. Vu= 6.33 kip Tue= 32.78 kip Design shear Design tension J:=T 3.23 ft•kip Design moment due to tension Design compression Design moment due to compression The VSU column base plates were also analyzed in RISAConnection for the above loads and the design results are attached. Nor 0 MI 1 NI 0 r"1 tJ n 1J r- 1 r1 t.J r-i tJ tJ r-i IIIRISA ANEMETSCHEK COMPANY Embed Plate - Compression: 2D Views Report Top view .5t 9 00 i 12.00 1 24.00 RISA Connection version 10t1 11.01.2019 Single Column Base Plate Connection continued on next page... Page 1 of 8 Li L_1 _J fl L -1 Li Embed Plate - Compression: LRFD Results Report LRFD 43 Single Column Base Plate Connection Material Properties: Column H559X5X3 4500 Gr.8 F y = 46.00 ksi F= 58.00 ksi Rect Base Plate P1.00x12.00x12 A36 Ey = 36.00 ksi = 58.00 ksi .00 Input Data: Axial Strong Axis Shear Note: Unless specified, all code references are from AISC 360-10 Limit State 49.21 kips Axial load on the column 6.33 kips Shear load on the column that causes strong axis bending Weak Axis Shear 0.00 kips Shear load on the column that causes weak axis bending Strong Axis Moment 0.00 kips-ft Column moment about the strong axis Weak Axis Moment 4.86 kips-ft Column moment about the weak axis Required Available Unity Check Result 'Geometry Restrictions PASS Load Distribution (Strong Axis) n/a il.oad Distribution (Weak Axis) n/a Concrete Bearing 0.10 PASS 'Lateral Slip 0.31 PASS plate Flexural Yielding(Compression)(Strong 0.19 kips-ft/in Wxis) 0.67 kips-ft/in 0.28 PASS Plate Flexural Yielding(Compression)(Weak 0.23 kips-ft/in Axis) 0.67 kips-ft/in 0.35 PASS Column Weld Limitations PASS Column Flange Weld Strength 0.00 kips/in 4.54 kips/in 0.00 PASS )rC-olumn Web Weld Strength 1.46 kips/in 4.54 kips/in 0.32 PASS n i1 Page 4 of 8 Embed Plate - Tension: 2D Views Report Too view D.50: 9.00 2.00 24.00 via.•Nor 44 Single Column Bose Plate Connection 40,1••••01111.111••••• Cr +ex; / continued on next page... Page 5 of 8 f li fl L Embed Plate - Tension: LRFD Results Report LRFD 45 Single Column Base Plate Connection Material Properties: Column HSS9X5X3 A500 Gr.B Base Plate Rect P1.00x12.00x12 A36 .00 F y = 46.00 ksi Fy = 36.00 ksi Fu = 58.00 ksi Fu = 58.00 ksi Input Data: Axial -32.78 kips Axial load on the column Strong Axis Shear 6.33 kips Shear load on the column that causes strong axis bending Weak Axis Shear 0.00 kips Shear load on the column that causes weak axis bending Strong Axis Moment 0.00 kips-ft Column moment about the strong axis Weak Axis Moment 3.23 kips-ft Column moment about the weak axis Note: Unless specified, all code references are from AISC 360-10 Limit State Required Available Unity Check Result Geometry Restrictions PASS Load Distribution (Strong Axis) n/a Load Distribution (Weak Axis) n/a Plate Flexural Yielding(Tension)(Strong Axis) 1.45 kips-ft 2.45 kips-ft 0.59 PASS Plate Flexural Yielding(Tension)(Weak Axis) 1.83 kips-ft 2.45 kips-ft 0.75 PASS (Anchor Bolt Tension (Strong Axis) 8.20 kips 21.57 kips 0.38 PASS lAnchor Bolt Tension (Weak Axis) 10.35 kips 21.57 kips 0.48 PASS 'Anchor Bolt Shear 6.33 kips 25.89 kips 0.24 PASS Anchor Bolt Bearing on Base Plate 6.33 kips 25.89 kips 0.24 PASS Column Weld Limitations PASS Column Flange Weld Strength 1.36 kips/in 4.54 kips/in 0.30 PASS Column Web Weld Strength 2.24 kips/in 4.54 kips/in 0.49 PASS Page 8 of 8 psi APPENDIX A SAFE MODEL REPORT AND LOADING DIAGRAMS SITTS & HILL ENGINEERS, INC. IAFE License #"13EXNKCVEENHQRA SAFE Analysis & Design Report Prepared by Sitts Hill Model Name: Proposed Foundation.fdb 1 November 2019 1 _J 1 j 7 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 1. Model properties 01 November 2019 1. Model properties This section provides model properties, including items such as material properties, section, properties, and support properties. 1.1. Material properties Table 1: Material Properties 03 - Concrete Table 1: Material Properties03 farm t aterlal E U A Unit kip/in2 1/F lbfft3 klp/in2 onc UserModRu p 4000Psi 3644.147 0,200000 5.5000E-06 1.5000E+02 4.000 No No 5000Psi 4074.281 0,200000 5.5000E-06 1.5000E+02 5.000 No No Table 2: Material Properties 04 - Rebar Table 2: Material Properties 04 - Rebar Material E UnitWt Fy Fu kip/in2 lb/ft3 kip/in2 kip/in2 A615Gr60 29000.000 4.9000E+02 60.000 90.000 Table 3: Material Properties 02 - Steel Table 3: Material Properties 02 - Steel - Material , E U A UnttWt Fy Fu kip/in2 1/F Ibfft3 kipAn2 kip/in2 Base Plate 29000.000 0,300000 6.5000E-06 4.9000E+02 36.000 58.000 1.2. Section properties Table 4: Slab Properties 02 - Solid Slabs Table 4: Slab Properties 02 - Solid Slabs Slab Type MatProp Thickness Ortho ' in Base Plate Stiff Base Plate 0.2500 No Existing Slab Slab 5000Psi 7.0000 No -1 Proposed Foundation Mat 4000Psi 27.0000 No fl 6-4 fl n Sitts Hill Page 2 of 14 PropnoedFoundadqn.fdb SAFE 201Gv10.O.2'License #~13BKNKCVEENHORA 1. Model properties 01 Nnvember2U18 1.3. Support properties Soil Properties Table 5: Soil Properties Subgrade - GnU Z5920E+05 Compression Only n fl 1fl b fl L Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 2, Model assignments 01 November 2019 2. Model assignments This section provides model assignments, including assignments to slabs, beams, and joints. 2.1. Slab assignments Table 6: Slab Property Assignments Table 6: Slab Property Assignments Area SlabProp — 1 1 Base Plate 2 Proposed Foundation 3 Base Plate 4 Base Plate 5 Existing Slab 6 Base Plate 7 Base Plate 8 Base Plate 9 Base Plate 10 Base Plate 11 Base Plate 12 Base Plate 13 Base Plate 14 Base Plate 23 Existing Slab 24 Base Plate 25 Base Plate 26 Base Plate 27 Base Plate 38 Existing Slab 39 Existing Slab 40 Existing Slab 41 Existing Slab 42 Existing Slab 43 Base Plate 44 Base Plate 45 Base Plate 46 Base Plate 47 Base Plate 48 Base Plate 49 Base Plate 50 Base Plate Table 7: Slab Vertical Offsets Table 7: Slab Vertical Offsets Area Offset in 1 3 4 6 Sitts Hill 0.2500 0.2500 0.2500 0.2500 Page 4 of 14 -1 -1 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #13EXNKCVEENHQRA 2. Model assignments 01 November 2019 7 1 7 fl n n fl 4-1 n 71 fl 4-1 r Table 7: Slab Vertical Offsets Area Offset in 7 0.2500 8 0.2500 9 0.2500 10 0.2500 11 0.2500 12 0.2500 13 0.2500 14 0.2500 24 0.2500 25 0.2500 26 0,2500 27 0.2500 43 0.2500 44 0,2500 45 0.2500 46 0.2500 47 0.2500 48 0.2500 49 0.2500 Table 8: Slab Edge Releases Table 8: Slab Edge Releases Area Edge Shear Moment 2 1 Yes Yes 2 2 Yes Yes 2 3 Yes Yes 2 4 Yes Yes 2 5 Yes Yes 2 6 Yes Yes 5 3 Yes Yes 5 4 Yes Yes 23 3 No Yes 38 1 Yes Yes 38 2 Yes Yes 38 3 Yes Yes 38 4 No Yes 39 1 No Yes 39 2 Yes Yes 39 3 Yes Yes 40 1 No Yes 40 3 Yes Yes 40 4 Yes Yes 41 1 Yes Yes 41 2 Yes Yes 41 3 Yes Yes 41 4 Yes Yes 42 1 Yes Yes 42 2 Yes Yes 42 5 Yes Yes 42 6 Yes Yes n Sitts Hill Page 5 of 14 --1 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #13EXNKCVEENHQRA 2. Model assignments 01 November 2019 -J ,-J LJ 2.2. Support assignments Table 9: Soil Property Assignments Table 9: Soil Property Assignments Area SoilProp 2 Soil 5 Soil 23 Soil 38 Soil 39 Soil 40 Soil 41 Soil 42 Soil Table 10: Point Restraint Assignments Table 10: Point Restraint Assignments Point Ux Uy Uz Rx Ry Rz 1 Yes Yes No No No No 2 Yes Yes No No No No 3 Yes Yes No No No No 4 Yes Yes No No No No 7 Yes Yes No No No No 48 Yes Yes No No No No 92 Yes Yes No No No No 94 Yes Yes No No No No 95 Yes Yes No No No No 96 Yes Yes No No No No 101 Yes Yes No No No No 104 Yes Yes No No No No 105 Yes Yes No No No No 116 Yes Yes No No No No 167 Yes Yes No No No No 168 Yes Yes No No No No 169 Yes Yes No No No No n Sitts Hill Page 6 of 14 94 PnppooedFoundahon.hjb SAFE 2O1Ov1S.O.2'License #^13EXNKCVEENHQRy\ 3. Model loading 01 Novembar2O19 Model � loading U��N������U �������Nng This section provides model loading information, including load patterns, load cases, and load combinations. � � � mK ~". x. u~K���wv pattems Table 11: Load Patterns Tamw1t Load Patterns 1.000000 0.000000 ooVuuoo 0.000000 oMOO8O Table 12: Load Assignments ~Surface Loads Table 12: Load Assignments - Surface Loads XE- w m� � r D Gravity 40*50zw o.n000E+no VoonnE+nu uoU 7 sx+ Gravity 144244.00 o.ounns~oo nMoos+uo 0.00 r sv+ Gravity 96528o0 o.nooVE+nn nMnoE+00 OM n o Gravity 40450.00 OMons+oo V.ononE+Vo 0.00 o EX+ Gravity 70475.00 ooOo0E+00 0.0000E+00 0.00 u sY+ Gravity 965eo00 o,uonos+oo v.uonos+oo 0.00 V D Gravity 40450.00 oonOVE+oo o.uVuoE+uo 0.08 n sx' Gravity 70475.00 n,U000E+OO o.VvooE+nO 0.00 o EY+ Gravity 96528u0 ouoouE+nn u.00nos+on 8.00 10 o Gravity 40450u0 u.000ns+oo 00000s+Vo 0.00 10 Ex' Gravity 144244.00 U.0oOoE+00 ooUnos+no 8.00 10 sY+ Gravity 9652&00 o.onous+oo o.000ns+nn 0.00 11 o Gravity ^Oono.no 000Uns+un O.0000s+oo 0.00 11 Ex+ Gravity 144244.00 00000s+ou oDoous+on 0.00 ^z o Gravity *0450.00 uonnnE+on oVonoe+Un OM 12 sx+ Gravity 70475uo VonnnE+on o,nonns+nn 0.00 13 D Gravity 40*50.00 n.0uoVE+00 oMoUs+oO 0.00 ,a sx' Gravity 70475u0 o,onoos+oV o.0000s+oo 0.00 14 o Gravity 40450M o.onnnE+oo nuoous+uo 0.00 14 sx' Gravity 1*12*4.00 n.000us+nn 000nns+nV 0.08 uo o Gravity 40*50.00 o.uoous+oo n.0000s+ou 0.00 43 EX' Gravity 1442*4.00 u.0000E+no n.00nos+Vo 0.00 43 EY+ Gravity 10129eM nMooE+oo nMons+00 0.00 44 o Gonnr *0450.00 oonous+on nV000s+nV 0,00 *4 sx' Gravity 7047e.00 oonOOE+no 000nns+on 0.00 *4 sY+ Gravity 101299u0 000noE+nn VnnonE+no 0.00 ** D Gravity *0450o0 n.uouos+ou o,oUooE+oo 0.00 45 sx+ Gravity 70475o0 oM0ns+00 0000ns+uo 0.00 *o EY+ Gravity 10129e.00 noonoe+oo o,Voons+00 0o0 ^n o Gravity 40*50o0 o.00nos+oo u.onoos+uo 0.00 46 sx+ Gravity 144244o0 00000s~ou o,00uos+on 0.00 * ° r-I rl PnopouedFoundohun.hjb 6AFE2U1Gv18.0.2'License #~13EXNKCVEENHQFA Tum,12: Load Assignments -Surface Luauw Area LoadPat ' oir ~' A B ^ c ' Ib/ft2 . IbIft3 Ib/fta ^ lb/ft2 46 B* Gravity 10299.00 u000s+00 o.00OOs 00 0.00 47 D Gravity 40450,00 0.0000e+00 Ooonns+nn 0,00 47 EX- Gravity 144244M n.00moE+00 0.O0oos+00 0.00 *7 EY- Gravity 101299D0 V.0Oo0s+00 o.onoos+Vn VOU 48 D Gravity 40450.00 0o000E+00 V.uoOoE+Oo OM 48 EX- Gravity 78475.00 U000E+00 V.0000E+00 0.00 48 EY- Gravity 101289o0 0.0000s+00 O.000OE+00 0.00 49 D Gravity 40450.00 U000E+00 O.UVO0E+00 0.00 49 EX+ Gravity 70475x0 DM0VE+00 V.VOOos+oo 0.00 43 EY' Gravity 101299.00 o,0000E+00 n.0o0VE+00 0.00 50 D Gravity 40450D0 o.00uoE+00 OuoonE+Un 0.00 50 EX+ Gravity 1442*4ou ooVnVs+VO U.Oo00E+0/ 0.00 oo EY- Gravity 10/299o0 VonnoE+oo oMuus+no 0.00 1 D Gravity 40450.00 o.8VVVE+00 o.nnOus+00 0.00 1 EX+ Gravity 144e4*.00 oMnnE+uu u.uom8E+00 0.00 n D Gravity 40450DO n.nUnUE+00 O.0O00E+00 0.00 3 EX+ Gravity 70475.08 oonuns+on O.unouE+00 0.00 4 D Gravity 40450.00 o.0V00E+00 V.0000E+00 0.00 4 EX- Gravity 70475.00 0.00nOE+00 0.0OoOE+00 0.00 8 D Gravity *0450.00 n,0nOVE+00 V,VOOuE+mo OM a EX- Gravity 144244M n,VVOOE+oo o,o000E+00 OM 24 n Gravity 48460,00 oMOuE+nV OMODE+OU OM 24 EX+ Gravity 144244M n.onnnE+no 0000us+ou 0.00 24 EY- Gravity 90528.00 O.OU00E+00 O.O0O0E+00 0.00 us D Gravity 40*50u0 nMnus+VV n.ononE+uo 0.00 zo EX+ Gravity 70475.00 OoVnos+00 U.0UOVE+00 0.00 25 EY- Gravity 9652&00 n.VO0UE+00 u.00une+nD 0.00 26 n Gravity 40450M ooO0Us+00 V.00OVE+DV 0.00 26 Ex' Gravity 70475o0 nMooE~on u,00noE+00 Voo 26 EY- Gravity 9852&00 nonoos+oo 000uos+00 0.00 27 D Gravity *0450.00 0,0000s+00 0,0000E+00 0.00 cr Ex. Gravity 144244.00 o.Onnns~no U.onnos+uo 0.00 or EY' Gravity 96528u0 V.Vonos+oV o.00nns+00 uVu rl Table13: Load Assignments -Point Loads, Part I of 2 rampm: Load Assignments ' Point Lvau�� PaIo,e r7 PointLpau�m '' Fp �� Fv' Fgra" u 71 -1 r� r-1 �_j rl kip kip kip 52 EX+ 6.330 0.000 U00 52 E» -6.330 umm '38M6 oc Ev+ 0.000 6,330 0,000 sz EY' 0,000 'e.aon '25,587 oo Ex+ 6.330 0.000 noVo nn Ex, 'o.00u 0,000 '18.681 nn Ev+ 0.000 aMn 0.000 sm EY' 0.000 'o.nno '25.*87 54 sX+ 6.330 0.000 '18.681 54 EX- 'sMn 0.000 nooV n* EY+ 0.000 *.330 oono m* EY' 0.000 '6330 '25587 oo Ex+ aMo n000 '3&236 -^ ShtsH0 Page 8of14 rl Lot Lad �7 | / wo PnoposedFoundaUon.fdb SAFE2O18v16l).2'License #°13EXNKCVEENHQRA Table 13: Load Assignments 'Point Loads, Part Iv,z Point LoadPat rx py perav kip kip kip 55 EX- -6.330 MOO MOO *s EY+ O.m0 6.330 umm 55 Er' 0-000 -6.330 -25.587 58 EX+ noao 0.000 0.000 sn sx' 'n.oam 0.000 -38.236 50 EY+ 0.000 6.330 UnV nO EY' ouoo '6.330 0.000 57 EX+ U30 0.000 0.000 nr sx' 'o.xuo ooOV '18.081 nr EY+ Moo 6.330 0.000 57 EY' 0.000 's.ono uDoo 58 EX+ 6.330 0.000 '18a81 nn sx' 'Uno 0.000 0.000 og EY+ 0MV 0.330 0,000 oo sY' 08OO '&330 0D00 59 EX+ 0.330 0.000 '38.236 58 Ex' '8.330 oonu 0.000 59 EY+ n000 6.330 0.000 5e EY' O.O00 '6.330 ODuV 202 EX+ 'UaV 0.000 '38�236 202 Ex' 6.330 0.000 0u00 zOe EY+ 0.000 6.330 0.000 znz sv' 0.000 's,uao 'us.xse zno EX+ '8330 0.008 '18.681 203 Ex. 6.330 0000 0.000 203 EY+ 0.0o0 6.330 0.000 uoo s,' 0000 '8330 '26o52 204 EX+ '8.330 0.000 nuoO zmu Ex 6.330 0.000 18.681 204 EY+ 0o00 6.330 VM0 204 sY' Unn '6.330 '2U52 205 EX+ '0,330 nuon 0,000 205 Ex' 6330 noVn '3823e 205 EY+ VMu 6330 0.000 205 eY' uMo 's.onn 'uo.noz 208 EX+ '*330 000n 'nnzon 000 EX' 6.330 0.000 0.000 206 EY+ 0.000 6.330 '26.852 zno s,' 0.000 's.onu oonn 207 EX+ '6330 0.000 '18.681 our sx' 6.330 oMo oMo onr EY+ 0,000 6.330 'usosz znr sv' nono 's.00u Uoo oou EX+ 's.oun ouoo 0.000 208 EX. 6.330 VMV '1oM1 znu EY+ 0000 6.330 'us,uno 208 EY' 0.000 '6.330 000u 209 sx~ 's.aao 0.000 noou 209 Ex. 6.330 0.000 '3e236 209 s,+ oMo 6.330 'zs.asz zoo e/' 0.000 's.00u 0.000 *7 EX+ 6,330 0.000 0.000 *r En- 'u.aau 0.000 '38z36 47 s,+ 0,000 6.330 0,000 PnopomadFnundohonjdb GAFE2O16v1U.O.2'License #°13EXNKCVEBNHORA Table 13: Load Assignments ' Point Loads, part Ic*u Point`'~'.LpauPatr4�' px py Fgmv kip kip kip 47 EY- 0.000 -6.330 0.000 49 EX+ 6.30 0,000 umm 49 EX- ~6.330 nunn '18.681 49 sv~ 0.000 6.330 0D00 ^e sY' Moo '6.330 0.000 nO EX+ 6,330 0.000 '18.681 oV E>- '6330 0.000 0.000 50 EY+ 0.000 0.330 0.000 50 sY' oMo '6.330 0.000 51 EX+ 6.330 0,000 -38z36 51 EX- '6.330 0.000 0.000 51 EY+ UVn 6.330 0.800 51 Ev' 0.000 'n.aoo 0.000 93 EX+ 8.330 U00 UMu 33 sx' '6.330 0.000 'oo.uos oS EY+ 0.000 8,330 '25.587 93 sY' oo0o -V000 0.000 100 EX+ 6330 nono 0.000 100 EX- -6,330 uoon '18.681 `On EY+ 0.000 V.:oo 'zo.sor 100 EY' 000n '6,330 nooV 102 EX+ 8a30 0.000 '18.881 102 sx' 'o.00n 0000 o.00u 102 EY+ 0.000 8.330 '25.587 102 Ev- 0.000 'n.00n 0.000 103 EX+ 6.330 0.000 '38.236 103 Ex- '6.330 0.000 0.000 103 EY+ 0,000 6330 'uaour 103 sv' oMo '6330 0.000 Table 13: Load Assignments -Point Loads, Part 2 of 2 Table 13: Load Loads, Part 2pv2 Point Mx Foy Niz, Min YDim kip-ft kip-ft kip-ft in in _ 52 0,0000 0,0000 oMn oMOO 0,000 nz 0.0000 0.0000 0.0000 KVouo 0,0000 52 0.0008 0,0000 0.0000 0.0000 0,0000 oz OMVn 0.0000 0.0000 0o000 OMO0 53 oonuO 8MOV 0,0000 oonOn oMoo 53 ooQoO 0,0000 0.0000 uoOoo n000m oo n000U oMOu 0.0000 oMoV V»oOo 53 0.0000 0.0000 0.0080 nonVo 8.0000 54 oMnO 0,0000 0.0000 0,0000 0.0000 54 000u0 0,0000 0.0080 0.0000 Vouuu 54 oMuo 0.8000 0.0000 0.0000 0.0000 54 0.0000 0.0000 nooOn uoonu 0,0000 55 0,0000 oMnO oMVU oonno 0.0000 55 0.0000 0.0000 0.0000 uoouo 0.8000 on 0.0000 0.0000 0.0000 0.0000 0.0000 55 ounoo 0.0000 0.0000 ooVVo 0.0000 56 0.0000 0,0000 0,0000 oaono 0.0000 56 00000 0.0000 0.0000 0.0000 0.0000 -I 'j ,A l 7 k-.d -� '-�j -1 .A .j '-.d PropouedFoundahon.fdb SAFE 2U18v1G.O.2'License #^13EXNKCVEENHQRA Tamw1a: Load Assignments 'Point Loads, Part um,a Mx My mz xDim Yoim 56 0,0000 0.0000 0.0000 0,0000 0.0000 56 0,0000 0.000oo000 U000 0,000 :r 0.0000 0.0000 0.0008 uuOOO nMno nr 0.0000 OMOU U.0000 0.0008 0.0000 57 U000 UMOO 0.0000 0M0D 0.0000 57 0,0000 0.0000 O0000 0.0000 0.0000 58 0,0000 0D000 0.0000 0.0000 0.0000 so UoVu 0.0000 0,0000 0,0000 0o000 *a 0.0000 0.0000 0.0000 0o000 0.0000 *8 UOOO 0.0000 0.0000 0.0000 0.0000 59 OMVo 0,0000 n.OoOo 0.0000 Uumo 59 oMOV 0.0000 n.n000 U000 U000 no VMoo Unon oonno 0.0000 0.0000 Sn U000 0.0000 VMUO 0.0000 8.0000 oDz 0.0000 0.0000 0o000 0.0000 ooUUO 202 0.0000 0.0000 0,0000 0.0000 0.0000 202 0.0000 0.0000 0.0000 0.0000 0.0000 202 0,0000 0.0000 0.0000 0.0000 0.0000 203 0.0000 0.0000 0.0000 0,0000 0.0000 203 0,0000 0.0000 UnoO 0,0000 0.0000 aun UOOo nMuo nunoo 0.0000 0.0000 203 U000 0.0000 0,0000 0.0080 0.0000 204 0.0000 0.0000 u000u oMou 0.0000 204 0.8000 0,0000 0.0008 0.0000 0.0000 204 0,0000 n0000 o»nno oouVU oonoo 204 0.0000 0.0000 OMo8 0.0000 0o000 205 0.0000 0.0000 0,0000 oMo0 ox000 205 UMOo oonOV 000no 0,0000 0.0000 205 0,0000 0.0000 0,0000 oMOO 0,0000 205 OM8U ouuuu oMoo 0.0000 uMoo zon 0,0000 oMuo oonoo 0,0008 0.8000 200 OMOo 0.0000 oMoO 0.0000 0.0000 206 V.0000 nM0V noono oMu8 oM0n 206 0.0008 OoOVV 0,0000 O�OOUU 0.0000 zor 0.0000 0.0000 Ou000 0.0800 0.0000 207 0.0000 0.0000 00000 000UV 0.0000 zor 0.0000 oMno o.onoo 0.0000 n000n 207 0MOO 0.0000 0,0000 0,0000 0.0000 cVa 0MVn oMVw oMoo 0.0000 0,0000 208 0.0000 0.0000 0.0000 OM8O 0.0000 oun 0o800 ou000 0,0000 oMuo 0.0000 zuo 0.0000 0.0000 0.0000 0.0000 0.0000 209 0.0000 0.0000 0,0000 0,0000 ouOUU 203 UoOU noOoV ooVon 0.0000 oMoV 209 0.0000 uu000 0.0000 0.0000 0.0000 ouo 0.0000 0.0000 nuuoo 0.0000 0.0000 47 8,0000 uMuu n.u000 0.0000 0,0000 47 nMVo 0.0000 0.0000 0.0000 uMuu *7 0,0000 UOOm 0.0000 0.0000 0.0000 47 0.0000 u000u oMou 0,0000 0.0000 49 0.0000 000OU oU000 0,0000 0.0000 49 0,0000 0.0000 nMnn 0.0000 0.0000 4e 0,0000 0.0000 0,0000 0.0000 0,0000 49 VuOoo 0.0000 000no 0.0000 0.0000 ,..A IR ER OW 14 Rod W OW will ' bmd ProposedFovndaUon.fdb 3. Model loading 50 50 50 50 51 51 51 51 93 93 93 93 100 100 100 100 102 102 102 102 103 103 `oa 103 SAFE 2O18v10]32'License #~13EXNKCVEENHC2RA 01 November2O18 Table 13: Load Assignments 'Point Loads, Part oofo ^ Table 14: Load Cases 02 - Static Zero Zero Zero Zero Zero Zero Zero Zero Zero Zero znm ze,p ze,v Linear Allow Uplift Allow Uplift Allow Uplift Allow Uplift Allow Uplift Allow Uplift Allow Uplift Allow Uplift Linear Linear Linear Linear Sbts Hill Page 12 of 14 � � PnnposedFoundaUon.fdb SAFE 2O1Sv1G]J.2'License #~13EXNKCVEENHORA ^ � Table 15: Load Cases 06-Loads Applied Tau�1e �oauCases ma'�pausxwpxou ° — _S F7 j ^ D D 1o00000 UD+0,7sY+ o 0.600000 0.60+07Ev+ Ev+ 0,700000 0.6O+VJEY' D 0.600000 Uo+o.rEY' EY' n�rOOmnO D+oJEx+ 0 1o00000 D+07EX+ EX+ 0.700000 V+VJEX- D 1.000000 D+07EX, EX' 0J00000 V+MEY+ D 1.000000 D+OJEY+ EY~ 0.700000 D+oJEY' D 1.000000 o+0.7EY' E,' 0.700000 o.uO+oJEX+ D 0o00800 o.sD+UJEX+ EX+ 0.700000 Mo+03Ex' Q 0.600000 0�61D+03EX' EX- 0J00000 EX+ EX+ 1.000000 Ex' Ex' 1oo0000 EY+ sY+ 1.000000 sY' Ev' I»no0no 3.3. u~��� y mK combinations Table 16: Load Combinations Tameon: Load Combinations Combo Load SF Type DSStrength OSServInit ommenwom omServLpng (0.9-0.2Sds)D+EK+ D M97800 Linear Add mm No No No (zM,23ds)D+EX+ EX+ 1M0000 (0.9-0,2Suo)D+sX' D 0.697800 Linear Add Yea No No No (0.9'0.2odo)D+E» EX' 1.000000 ().9-02auo)D+Ev+ D 0a97800 Linear Add ,vo No No No (o.m'n.zoum)n+EY+ Ev+ 1o00000 (0u'V.aSua)o+EY' D 0,697800 Linear Add Yes No No No (0.e'0,2Guo)o+Ev' sv' 1.on0000 (1.2~0.2ous)o+sx+ D 1.*02200 Linear Add Yes No No No (,.z+V.zSgy)D+EX+ EX+ 1,000000 (1.2+0.2Sdo)o+EX' D 1A02200 Linear Add Yes No No No (1.2+02sus)o+s>- Ex' 1,000000 (12+0.2Sdo)D+EY+ V 1A02200 Linear Add Yes No No No (1,2+0.2Sds)o+EY+ sY+ 1Vo0000 (1.2+0,2auu)D+sY' D 1 A02200 Linear Add Yes No No No (1 Ev' 1on0000 SittoHiU Page 13of14 n fll Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #13EXNKCVEENHQRA 4. Design summary 01 November 2019 4. Design summary fl n n n n n LJ I-J n fl n n P LJ 1 li This section provides design information for beams, strips, and punching checks. 4.1. Preferences Table 17: Design Preferences 01 - Resistance Factors Table 17: Design Preferences 01 - Resistance Factors PhiTen PhiComp PhiShear Jr 0.900000 0.650000 0.750000 Table 18: Design Preferences 02 - Rebar Cover - Slabs Table 18: Design Preferences 02 - Rebar Cover - Slabs CoverTop CoverBot BarSize InnerLayer PTCGSTop PTCGSBotE PTCGSBotI SlabType xt nt in in 46 ,44 in in in 2.9375 3.9375 #6 8 1.0000 1.7500 1.0000 Two Way Sitts Hill Page 14 of 14 Proposed Foundation Slab Surface Loading inGravity Direction (]) Ob/ft2l 11/1/20191]31 PM Proposed Foundation SAFE 2016 16.0.2 Point Loads (EX-) [kip, kip-ft] 11/1/2019 1:10 PM kip - ft Proposed Foundation SAFE 2016 16,0.2 Slab Surface Loading in Gravity Direction (EX-) [Ib/ft2] 11/1/2019 1:05 PM kip - ft Proposed Foundation SAFE 2016 18.0.2 Point Loads (EX+) [kip. kip-ft] 11/1/2019110PM Proposed Foundation Slab Surface Loading inGravity Direction (EX+) Db8t2] Proposed Foundation SAFE 201S1G1].2 11/1C2019111 PM Proposed Foundation i Slab Surface Loading inGravity Direction (EY-) [lb/ft2] Proposed Foundation SAFE 2016 16.0.2 11/1/2019 1:11 PM Point Loads (EY+) [kip, kip-ft] kip - ft Proposed Foundation Slab Surface Loading inGravity Direction (EY+) Ob/ft2 APPENDIX A KARDEX REMSTAR DOCUMENTS SITTS & HILL ENGINEERS, INC. 1 1 1 LJ n fl n n b n fl n LJ LJ n n n Supporting contact surface 8 x 140 cm2 Personal protection light curtain holder or cable duct for multiple access openings Boeing Seattle LAYOUT PLAN HD-500 2450 mm x 863.6 mm x 8050 mm (96.46 in. x 34 in. x 26 feet, 4.93 inches) E E. cp power u ly 2400 mm (94.49 in.) Hole for floor anchoring 0 14 mm (0.55") table (front) Unit Width: 2780 mm (109.45 in.) E E CNt 205 mm (fon X = 528.7 mm (20.81 in.) Y =1606.5 rim (63.25 in.) Personal protection light curtain holder 205 mm (8.07") 40 mm CI St Unit Depth: 3073 mm (120.98 in.) This layout does not account for extraction table dimensions, if chosen on POF; only the basic access opening. - The weight load is transferred to the supporting contact surfaces at the base frame via eight load profiles. The supporting surfaces are the contact surface for the complete machine. - (Total) Supporting Contact Surface: 173.6 in.2 (1120 cm2) - X: Spacing of outer load profiles Y: Spacing of inner load profiles - The evenness of the floor surface, on which quality assured products are installed, must be within the admissible tolerances: Up to 10 meter unit height, distance = 12mm (0.47 in.) - Unit must be anchored to the foundation - The front edge of the access table and the personal protection light curtain protrude the access opening by 40 mm (1.57") Specifications for Shuttle XP HO-500 2450 mm x 863.6 mm x 8050 mm (96.46 in. x 34 in. x 26 feet, 4.93 inches) Quantity of Units . Overall Unit Height . The required room freight ( unit height # 2Omm /0,79") is 3 26 feet, 4.93 inches Required Room Height 26 feet, 5.76 inches the absolute minimum measure. Possible floor/ceiling unevenness and slope must be considered therein, Overall Unit Width Overall Unit Depth Shuttle Weight Weight of Trays Approx. Weight Empty w/Trays Approximate Weight Fully Loaded as Configured Tray Type 109.45 In. 120.98 in. 7,250 Pounds Empty without Trays, Product, etc. 8,311 Pounds (Average per Unit) 15,561 Pounds (Average per Unit) 85,778 Pounds (Average per Unit) Quantity Clear Width x Clear Dep Avg./Unit Total/Order Load Per Tray (lb: Maximum Light Trays . Medium Trays Heavy Trays : "Medium X Type 2 Trays "Medium Universal 5 Type 2 Trays , Medium XL Type 1 Deep Trays Medium XXL Universal Trays : 'Medium Universal RS Type 2 Trays . •Med6um XL Type 2 Deep Trays : Heavy XL Type 1 Deep Trays : "Heavy XL Type 2 Deep Trays : Frame R XXL Trays Heavy S XXL Trays Medium $ XXL Trays : Medium Universal R Type 2 Trays , Medium Universal R Type 3 Trays : 96.46 In. x 34 in. - 0 96.46 in. x 34 in. 0 96.46 in. x 34 in. 47.74 in. x 2 x 32.27 In. x 2 x 33.72 In. 96.46 in. x 33.6 in. 96.46 In. x 33.6 In. x 2 x 33.72 in. 47.74 In. x 2 x 33.6 in. 96.46 in. x 33.6 in. 47.74 in. x 2 x 33.6 In. 95.08 In. x 33.6 in. 96.06 in. x 34 In. 95.08 in. x 33.6 in. x 2 x 33.72 in. 51.85 in. x 2, 52.16 in. x 1 x 33.72 in. 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 95 0 0 0 0 0 0 0 0 0 0 0 0 507 794 1080 "divided by a reinforcement bar which is adjustable on 50mm (1.97") centers up to 200mm (7.87") from center of troy, left or right Minimum Tray Spacing . S Maximum Tray Spacing : 29.53 Clearance Required Above Product : 0.79 Inches Maximum Product Height : 28.74 inches (730mm) Inches Shelf Rails (tray supports) : 264 Storage Locations Possible : 528 Maximum Unit Capacity : 147,708 Pounds Unit Capacity after tray weight deducted: 144938 Pounds Lifting Speed : 157.50 Lifting Speed if Extractor is w/o a Tray : 246.05 Extractor Speed Pick Performance (Average Qty.) ft./min. ft./min. in./sec. 101 Trays/hour (does not consider operator picking time) Complete Cycle (Storage + Retrieval) Single Cycle (Tray Retrieval only) Average Access Time : 35.46 Maximum Access Time : 44.82 Seconds Seconds 16.73 Seconds 20.41 Seconds Calculation of access times is based on: 1) Speed adjustment lift (vertical) at 100%; extractor (horizontal) at 100%. Note: 100% extractor speed is not recommended for some storage goads. All delivered units have a pre -defined setting of 70%. 2) Shutter door is set to dosed during lift movement, i.e. tray positioned in access opening is in 'fingerhold.' Note: This setting is only possible with units equipped with 1 access opening. With the setting "always closed," the access times will increase by "6 seconds. 3) Options chosen on POF, such as automatic extraction will affect times outlined above. 4) Weight management : Activate weight ma update access times above 0 ACTIVATE (Adds S seconds to access dme) With time -critical units (e.g. high performance order picking units or robot handling with cycle times) a prior consultation with the factory is recommended. Power . Maximum Power Consumption : Full Load Amp (FLA) . Max. Circuit Breaker Rating for Supply (Delayed) . 480 Volts/3`/PE 8.6 kVA 14.2 Amp Per Machine 15 Amp Per Machine Color Load Profiles and Panels Shelf Rail Panel Exteriors Side Service Panels Tooth Belt Drive Safety Shutter Door System Control Type Operator Panel OP Logicontrol Location Access Ready Lights Confirmation Bar Transport Cart Crane and Support Frame Extraction Table External P5/2 Interface Vertical Photocells to Monitor Extractor Column ESD Equipped Trays Transaction Information Center Light Pointer Position Indicator Light Bar RAL 5015 Sky Blue /RAL 7035 Light Gray RAL 7035 Light Gray One side Swing / one side Fixed Yes Yes Controls 3000 Inside Overhead Center/access No Yes No No No No Yes No Yes Yes LED SPOT, 40 mm dia. No Storage/Surface Area Offered : 1,481 Gross Cube 989 Useable Cube when Trays installed : 891 Avg. 5q. Ft. of Surface Area Provided per Shuttle Cubic Ft. per Shuttle Cubic Ft. per Shuttle, 713 Cubic Feet @ 80% Utilization Printed: 12/21/2018 XP POF Version 8, 1-2018 Boeing Seattle FLOOR LOADING Shuttle XP HD-500 2450 mm x 863.6 mm x 8050 mm (96.46 In. x 34 in. x 26 feet, 4.93 inches) Information provided below Is per unit (wham mare than I unit, trays are divided by I t of units Jar en average/unit) The floor loading calculations comply with the General Duality Assurance and Test Regulations for Storage and Factory Equipment, RAL-RG 614 Surface pressure: The customer must ensure and should guarantee the floor has sufficient capacity to absorb the surface pressure. Floor load -bearing capacity: The customer must ensure that the floor has sufficient capacity to absorb all loads imposed by the equipment The customer must provide the Kardexiiemstar representative with all information regarding present and future room conditions. If no other information Is provided, you can proceed on the assumption that a minimum surface pressure ol of 5 N/rrn2 (725.19 psi) is acceptable. Maximum surface pressure: Unit deadweight - MLar : Max. load (gross) - Memo" : mow. : FF. , amax. : (Bearing surface = 14000) MLar + maw. = m0. x 9.81 mfs' . FFGes. 3289 kg. 67000 kg. 70289 kg. 689532 N 6.16 N/mm' - 8 x 14000 mrn' Maximum surface pressure/ PSI: amax. x 145.04 = 893.45 psi Actual occuring surface pressure: FFGesfiat = Acteal load per unit [N] slat, =Actual surface pressure [N/mml A =8eaflflgsurfnce(4,1mrna) 1 °min.' = Assuming minimum surface pressure of floor IN/rnmq FFGesitat crmin. 2 crtat tat: i 8 x A : Unit adweylst - 3239 kg. Total Tray dead wtight- 10 Trayslx e eat, wt.,c_ti 3770 k . ax tray load z„, la3 Trays, x lsssd cscls 3t450 mGes.Mx FFoes. :nsGes.tat.x Mal : + + 9.81 mIs = FFGes. 381694 N 3.41 N/mm' 8 x 14000 me- - . , c , ot1. 14304..... ‘194.29 psi Max. required floor load capacity: Max. Issua;:ual - 1+14f.,S,„ . .. _ MGes„,.. = Max. Total Weight (kg.) 'limy' = Unit dead weight (kg.) fne.flool = Max. gross load (kg.) r0L.7., • rnb.,,ro --. sozsSg. Calculation of maximum floor load bearing capacity: Fri = Load per unit (N) knot = Unit base [m'l ' uw. = Unit width (m( . UD = Unit depth Inv] P„..c = Max. floor load bearing capacity (N/m2) _ . i P,... = Assuming min. floor load capacity [N/m'l Maximum Load per unit - FF : Unit base [erri - - : mGesx 9.81 mIs' UW x UD = FFGes. 689532 8.54 a? 80741 Him' AG.* - 81 kN/m2 Makinstins "...Id 11.-a1ng 17 A auhr t ; : a .0 l' 'a LL,71 psi Actual required floor load bearing capacity: MGes5 = Actual Total Weght (kg.( MiGT = Unit dead weight (kg.) ITIen.osi = Max. gross load (kg.) r, K ,M, a, ',. kl_. Calculation of actual floor load bearing capacity: Actual Load per unit (N) _ _ . ....... - Aura', = Unit base (rn'l , . UW = Unit width (m( r- UD, = Unit depth Irnl Actual floor load bearing capacity [1.1/mi1 1 Assuming min. floor load capacity [N/m' Actual Load per unit - FF , mGes,,x 9.81 rnis' = 381694 N Kardex Remstar, LLC Date Printed 12/21/2018 n n n fl L-1 n n fl n 1 n n n n li 14 fl Unit base [mai - UW x UD FFGesitat, 8.54 ma 44695 N/ma 45 101/m2 Actua Roor Load Bea,1ngCapadtyJPSI Pme X 00014504 6.48 psi r-1 Kardex Remstar, LLC Date Printed 12/21/2018 b REVIEWED FOR CODE COMPLIANCE APPROVED AUG 27 2019 City of Tukwila BUILDING DIVISION AUG 1 5 2019 SITTS & HILL ENGINEERS, INC. Professional Engineers & Planners CIVIL STRUCTURAL AND SURVEYING ck- 01(0'4 I■1 ER Nu MI • NMI FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 2-10 TUKWILA, WA 98108 CALCULATIONS PREPARED FOR THE BOEING COMPANY POST OFFICE BOX 3707 SEATTLE, WA 98124 PREPARED BY Sitts & Hill Engineers, Inc. 4815 Center Street Tacoma, WA 98409 August 9, 2019 S & H Job Number: 18,391 SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT FOUNDATIONS FOR VERTICAL STORAGE UNITS CALCULATION INDEX DESIGNED EMF DATE 8/9/2019 JOB 18,391 CHECKED AJB DATE 8/9/2019 PAGE 1 BASIS 2 - 4 DESIGN CRITERIA AND ASSUMPTIONS FOUNDATION AND ANCHORAGE ANALYSIS • Column and Anchorage Loading 11 - 12 two Foundation Analysis 13 - 21 • Punching Shear 13 Flexural Strength 14 - 22 Bearing Capacity 23 - 25 Anchorage Analysis 26 - 32 APPENDICES • • 5-9 10 - 32 SAFE Model Report and Loading Diagrams Appendix A Kardex Remstar Documents Appendix B 1 1 1 r 1 BASIS FOR DESIGN SITTS & HILL ENGINEERS, INC. o 8)|5&HILL ENGINEERS, INC. rAcoMA, W«sx/msrow (253)474-9449 PROJECT FOUNDATIONS FOR VERTICAL STORAGE UNITS ososwcn EMF DATE 8/9/2019 um 18,391 CHECKED AJB DATE 8/9/2019 I BASIS FOR DESIGN BUILDING CODE: 2015 Edition ofthe International Building Code with State ofWashington and City ofTukwila amendments shall beused and supplemented with AS[E7'lO. MATERIALS CODES: Building Code Requirements for Structural Concrete, AI|318-14. Specification for Structural Steel Buildings, ANSI/AISC 360-10, � RISK CATEGORY: � SEISMIC IMPORTANCE: GRAVITY LOADS: LATERAL LOAD CRITERIA: STRUCTURAL STEEL: N � w CONCRETE: � � � � � � / � 1� U. Weight ofVSU=7,Z5O|bf,per manufacturer. Weight of trays =8,3l1 |bf, per manufacturer, Weight of fully loaded V5U=85,778IV, per manufacturer. Weight of fully loaded tray = 1080 IV, per manufacturer. (2) Trays per shelf level. Seismic Site Class: D (assumed). Seismic Design Category: D. Minimum compressive stnangthcfpnzposedV5Ufoundadnnis4'U0Opsi Minimum assumed compressive strength of the existing concrete slab on grade is 5,000psi. Assumed allowable soil bearing pressure =1,5OOpsf. Assumed allowable soil bearing pressure under seismic loading =Z'0O0p$[* * using industry common 1/3 bearing pressure increase for transient loading Assumed modulus of subgrade reaction = 150 pci. SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT FOUNDATIONS FOR VERTICAL STORAGE UNITS SEISMIC DESIGN CRITERIA - SITE DESIGNED EMF DATE 6/4/2019 JOB 18,391 CHECKED AJB DATE 6/4/2019 PAGE 4 Address: 1135 S. WEBSTER ST. TUKWILA, WA 98108 • ' - " . 14' — — d • 444 it/ 14 4,444 raga 424 -4 - i• Aor * 4•47;:y Site Class: D (Assumed) ASCE 7-10, SECTION 11.4: Fa = 1.00 (Table 11.4-1) Sms = SsFa = 1.516 x 1.00 (Equation 11.4-1) Sms = 1.516 SD5 = 2/3 Sms = 2/3 x 1.516 (Equation 11.4-3) Sps = 1.011 ASCE 7-10, SECTION 11.5: Risk Category: II ASCE 7-10, SECTION 11.6: Seismic Design Category: D Latitude: 47.5318 Longitude: -122.3151 S5 = 1.516 = 0.579 (USGS) F„ = 1.50 (Table 11.4-2) Smi = SiFy = 0.579 x 1.50 (Equation 11.4-2) Smi = 0.868 SDi = 2/3 SM1 = 2/3 x 0.868 (Equation 11.4-4) SDI = 0.579 le= 1.00 (Table 1.5-2) (Based on Tables 11.6-1 and 11.6-2) DESIGN CRITERIA AND ASSUMPTIONS SITTS & HILL ENGINEERS, INC. Imml IMI SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 6 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 DESIGN CRITERIA AND ASSUMPTIONS: Seismic Classification per ASCE 7-10 The VSU drawings provided by Kardex Remstar do not clearly identify a lateral force resisting system. Although the load distribution provisions for steel storage racks defined in section 15.5.3 appear appropriate for the purposes of determing the operating weight and vertical force distribution of the structure, the definition of steel storage racks in section 11.2 does not allow us to logically classify the structure as a steel storage rack for determination of seismic response properties. The VSU's are most accurately characterized as nonbuilding structures not similar to buildings per chapter 15. However, the only lateral force resisting system in Table 15.4-2 that appears to be applicable to the VSU's are "All other self-supporting structures...not similar to buildings". Therefore, the seismic coefficients for this system are used in the design of the foundations and anchorage. Existing Concrete Slab on Grade Grid lines are spaced at 60' on center in the east -west direction and at 20' on center in the north -south direction. Control joints are present at each gridline, and an intermediate control joint is present between the columns in the east -west directions, bringing the spacing between control joints to 30' on center. Cracks were observed in the north -south direction at the middle of this 30' span at a number of locations. Therefore, the floor slab for the VSU foundation is modeled as a 20'x30' element with a shear transfer only joint at the middle of the 30' span. See the sketch below for a graphical depiction of the described slab conditions and approximate locations of the proposed VSU's. 20' FLEXURAL CRACK -20' PROPOSED VSU LOCATIONS CONTROL JOINT, TYPICAL • rrpAt-prl %mith PT( MAthrAri Fynrracc cPP INNA/W rrAthrArl rnm frw mnrp infnrmatinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 7 CHECKED: AJB DATE: 08/09/2019 Analysis Procedure: As noted in the Scope of Work, our analysis does not include checking the structural adequacy of the superstructure of the VSUs. The weight of the structure, seismic base shear, and seismic overturning moment are used to compute shear, tension, and compression forces at the column and anchorage locations noted on the VSU drawings. These forces are applied to analyze the VSU foundations and anchorage. The software program SAFE, version 16.0.2, is used to model the proposed foundation and compute the demand punching shears, design the foundation reinforcing, and assess the soil bearing pressures. The the VSU anchorage is designed according to the provisions of ACI 318-14 Chapter 17. The overstrength factor, flo, is applied to the seismic forces used to design the anchors for shear loads, and the anchors are designed for a ductile failure mechanisrn in tension per ACI 318-14 17.2.3.4.3 (a). Vertical Storage Unit (VSU) Dimensions Surnesigamitt surfage 14i)cegz Xt Hear far flay anchoring id Ira Ass, d likidift V130 tam (159 d5 ) 52ill ion imai 114 r5rem rrca DTr Mat -Fir •••1 vrwocc iCat=1 1A/1A/1A/ rriat-hcri rnm ft-1r Crinria infnrmAtinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 8 CHECKED: AJI3 DATE: 08/09/2019 B =109.45 in Width L := 120.98 in Length H:=26.41 ft Height Ab= 8.07 in • 4.73 in= 38.2 in2 Bearing area per column n:=8 Number of columns X, := 104.72 in Distance between compression centers, x-direction Xt:= 94.49 in Distance between tension centers, x-direction d = distance between compressions and tension centers in the x-direction as calculated in the anchorage analysis := 28.88 in Y2 := 55.18 in Y3 := 28.88 in VSU Gravity Loads: We =7250 lbf + 8311 lbf = 15561 lbf Weight of VSU and empty racks We,:= 85778 lbf Maximum operating weight of VSU Wr := — = 70217 lbf Maximum storage load in VSU Wi := 2 1080 lbf = 2160 lbf Maximum load per storage level in VSU VSU Seismic Loads per ASCE 7-10: Seismic Coefficients and Properties: /,:= 1 R := 1.25 120:= 2 .9 a s := 1.011 SDS = 0.8088 Seismic Importance Factor per Table 1.5-2 Response Modification Factor per Table 15.4-2 Overstrength Factor per Table 15.4-2 Short-term design spectral response acceleration Seismic response coefficient per Equation 12.8-2 Created with PTC Mathcad Exnress. See www.mathcad rnm for mnre, infnr-nnAtinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 9 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 Seismic Base Shear and Distribution: The operating weight of the structure and the vertical distribution of seismic forces can reasonably be determined in a manner similar to the provisions provided by section 15.5.3 for steel storage racks. Two loading conditions must be considered when computing the operating • weight for calculation of the seismic base shear per section 15.5.3.6: (a) Weight of racks plus every storage level loaded to 67% of its rated load capacity (b) Weight of racks plus highest storage level only loaded to 100% of its rated load capacity The base shears corresponding to these requirements are: :=Cs • (W, + 0.67 Wp) = 50636 lbf Condition A seismic base shear per Equation 12.8-1 - Vb:=Cs• (We-FW, 14333 lbf Condition B seismic base shear per Equation 12.8-1 1 The distribution of the seismic base shear is performed in accordance with ASCE 7-10 Sections 15.5.3.7 and 12.8.3. The weight of the structure and racks is assumed to be evenly distributed across the height of the structure, and the storage weight is distributed according to section 15.5.3.6. The resulting overturning moments due to seismic loading for loading conditions A and B are as follows: Condition A: Loads evenly distributed across the height of the structure result in a center of action of seismic force at 2/3 of the height of the structure. Ma:=Va •-2 H =891532 lbf • ft 3 Condition B: Condition A seismic overturning moment k 1 Per Section 15.5.3.7 (c) W•Hk =0.217 Vertical distribution factor of top rack load per Equation 12.8-12 • Hk + We • jve H 2, Mb:="Vb' :vi. H Cve • 2 Condition A loading controls. =0.783 Vertical distribution factor of structure and racks per Equation 12.8-12 =230390 lbf • ft Condition B seismic overturning moment mo:= =891532 lbf • ft V :=Vti= 50636 lbf rro 1Alifh QT( M1hrdPvnracc cPin 1A/1A/tA/ mathrAri crim fnr mnrP infnrmAtinn FOUNDATION AND ANCHORAGE ANALYSIS SITTS & HILL ENGINEERS, INC. SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 11 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 FOUNDATION AND ANCHORAGE ANALYSIS: Column and Anchorage Loading: Dead and Seismic Shear Loads: Wo PD := = 10722 lbf 8 Ab V V E := ---8 = 6330 lbf PD 4 450 psf Dead load per VSU column Dead load over bearing area per VSU column Seismic shear load per VSU column Seismic Axial Loading Analysis About Length Axis: d:=X, =99.6 in Distance between compression and tension 2 centers of VSU columns across length axis M PE1:= = 26852 lbf Seismic axial load per VSU column 4 d PE1 CE1:== 101299 psf Ab Seismic axial load over bearing area per VSU column Seismic Axial Loading Analysis About Length Axis (2 VSU's Tied Together Along Length Axis): I X,— Xt\ B—X, 2 , 2 B—X,) ±B 2 ) 2 MO PE2:= = 25587 lbf 4 d PE2 CE2:= = 96528 psf Ab = 209 in Distance between compression and tension centers of VSU columns across length axis Seismic axial load per VSU column Seismic axial load over bearing area per VSU column Seismic Axial Loading Analysis About Width Axis: 2 /Y2\2 / Y2 /:= 4 — + 4 + Y1 =15800 in2 Moment of inertia of VSU column group 2 2 about width axis / Y2 av4°. 2 =18681 lbf Seismic axial load per interior VSU column ‘Afith DT(' M Pvnracc Cc.4:1 ‘A/MIAI rnm fnr mrtrP infnrmAtinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 12 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 CE3 ' PE3 = 70475 psf Ab Y2 +Yl 2 =38236 lbf I CE4 AE4 =144244 psf b Seismic axial load over bearing area per interior VSU column Seismic axial load per exterior VSU column Seismic axial Toad over bearing area per exterior VSU column Created vvith PTC Mathcad Express. See www.mathcad.com for more information. 1 1 1 • 1 • • SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 13 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 Foundation Analysis: The proposed foundation was modeled according to the design criteria and assumptions using the software program SAFE 2016, and dead and seismic loads were applied to the model as calculated above. The foundation was assessed for punching shear and flexural capacity using LRFD load combinations, and for bearing capacity using ASD load combinations. A SAFE model report and loading diagrams can be found in Appendix A, and graphical results for the flexural and bearing capacity checks can be found in their respective calculation sections. Punching Shear (ACI 318-14 Table 14.5.5.1): := 0.75 Strength reduction factor for shear per ACI 318-14 Table 21.2.1 fc:= 4000 psi Compressive strength of concrete h:= 27 in Foundation thickness d := h-- 3-0.625.1.5=23.06 in Depth to reinforcement A:= 1.0 Factor for normal-weioht concrete 2.4.73 in =1.17 8.07 in Ratio of long to short side of load area of tied columns t0:=2 ((8.07+d)-1-(4.73 .2+0=127.31 in Punching shear perimeter a := 40 / / / min 4 A • 2+-4)• f , , 2+ • d 1 \ \ bo Vn:= =742.778 kip 1000 ACI 318-14 Section 22.6.5.3 • = 557.08 kip Nominal punching shear strength per ACI 318-14 Table 22.6.5.2 Design punching shear strength Maximum LRFD Vu := 2 (0.2+ 0.2 Sps) • Pp+ max (PEI ,P E2 PE3 PE4)) 106.54 kip demand punching shear cb • Vn > OK 1 Created with PTC Mathrad Fxhress. See vvvvw_mathcad rhm f:nr mnrp infnrmation NU • mil SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units Flexural Strength: Minimum shrinkage and temperature slab perAC! 318-14 Table 7.6.1.1: As_min:= 0.0018 h• 12 = 0.583 ft in2 A#6'.= • 0 44 in2 s:=8 in A, .=A#6. 12 in = 0.660 in2 ft As> Asmi„ .^. OK JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 14 CHECKED: AJB DATE: 08/09/2019 reinforcement is provided at the top and bottom of the Minimum reinforcement per ACI 318-14 Table 7.6.1.1 Cross -sectional area of #6 reinforcing bar Spacing of reinforcement Area of steel provided per foot Reinforcing of #6 @ 8" is specified in the SAFE model, and the attached program output details the amount of reinforcing required above the specified reinforcement as well as the maximum moment intensity diagrams. Per the SAFE analysis, additional reinforcement of under 0.02 inA2/ft within a 5'x5square area around the footprint of the interior combined columns is required, and lightly larger amounts of reinforcement (up to 0.1225inA2/ft) are required in the immediate vicity of the combined column. The excess reinforcement required in the region around the interior combined column can be attributed to the way that SAFE distributes the highly concentrated load throughout its finite element mesh, we believe that the #6 reinforcing bars at 8" O.C. sufficiently reinforce the foundation, and the localized effects can be safely neglected. Created with PTC Mathcad Exhress_ Spp wwwmthrtrnm fnr morP infnrrnfinn 15 Proposed Foundation 7/5/2019 10:27 AM *my ADDITIONAL REINFORCING REQUIRED = 0.0546in^2/ft ADDITIONAL REINFORCING REQUIRED ; 0.01in^2/ft 195 180 165 150 135 120 105 90 75 60 45 30 15 0 E-3 SAFE 2016 16.0.2 Top Rebar Intensity (Enveloping) [in2/ftl - Direction 1 - Additional to #6 @ 8 in kip - ft 16 Proposed Foundation 7/5/2019 10:29 AM ADD TIONAL REINFORCING REQUIRED < 0.02in"2/ft ADDITIONAL REINFORCING REQUIRED = 0.1225in"2/ft ADDITIONAL REINFORCING REQUIRED < 0.003in"2/ft 52 48 440 400 360 320 280 240 200 160 120 80 40 0 E-3 0 0 SAFE 2016 16.0.2Bottom Rebar Intensity (Enveloping) [in2/ft] - Direction 1 - Additional to #6 @ 8 irkip - ft Proposed Foundation 7/3/2019 5:03 PM SAFE 2016 16.0.2 Top Rebar Intensity (Enveloping) [in2/ft:] - Direction 2 - Additional to #6 @ 8 in kip - ft 17 i 911 MEI Proposed Foundation 7/3/2019 5:05 PM 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SAFE 2016 16.0.213ottom Rebar Intensity (Enveloping) [in2/ft] - Direction 2 - Additional to #6 @ 8 inkip - ft 18 19 Proposed Foundation SAFE 2016 16.0.2 Slab Resultant Mmax Diagram - ((1.2+0.2Sds)D+EX+) [kip-ft/ftj 7/31/2019 9:36 AM kip - ft LA {,l i i i • Proposed Foundation SAFE 2016 16.0.2 Slab Resultant Mmax Diagram - ((1.2+0.2Sds)D+EY-) [kip-ft/ft] 8/2/2019 10:59 AM kip - ft 20 A 21 Proposed Foundation 7/31/2019 9:49 AM Morin = 62.44kip-ft/ft 60.0 50.0 40.0 30.0 20.0 10.0 0.0 -10.0 - 20.0 -30.0 - 40.0 - 50.0 -60.0 -70.0 SAFE 2016 16.0.2 Slab Resultant Mmin Diagram - ((0.9--0.2Sds)D+EX-) [kip-ft/ft] k p-ft 22 Proposed Foundation 8/2/2019 11:05 AM Mmin = 21.96kip-ft/ft 24.0 20.0 16.0 '12.0 8.0 4.0 0.0 -4.0 -8.0 -12.0 -16.0 -20.0 -24.0 -28.0 SAFE 2016 16.0.2 Slab Resultant Mmin Diagram - ((1.2+0.2Sds)D+EY-) [kip-ft/ft] kip - ft 5 5 SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units Bearing Capacity: Dead Load: Cr allowable : 1500 psf o-D:=876 psf cr allowable Dead + Seismic Load: U allowable := 2000 psf o-E:=1810 psf r allowable •. OK . OK JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 2 3 CHECKED: An DATE: 08/09/2019 Assumed allowable bearing pressure Maximum bearing pressure under dead loads per attached SAFE model output Assumed allowable bearing pressure Maximum bearing pressure under dead and seismic loads per attached SAFE model output Created with PTC Matheari Fynrecc_ cPP VOAAN mathrarl rnm fnr mnre infnrmatinn Proposed Foundation SAFE 2016 16.0.2 MAXIMUM BEARING PRESSURE = 876psf Soil Pressure Diagram - (D) [Ib/ft2] 7/3/2019 5:15 PM kip -ft 24 r i Vt Proposed Foundation 7/3/2019 5:13 PM MAXIMUM BEARING PRESSURE = 1810 psf SAFE 2016 16.0.2 Soil Pressure Diagram - (0.6D+0.7EY+) [Ib/ft2] E+3 0.002 -0.15 -0.30 -0.45 - 0.60 -0.75 - 0.90 - 1.05 -1.20 - 1 35 -1.50 - 1 65 - 1.80 -1.95'r kip - ft 25 lo SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 26 CHECKED: AJB DATE: 08/09/2019 Anchorage Analysis: The anchors are designed and detailed to induce a ductile failure mechanism in the anchors per ACI 318-14 17.2.3.4.3 (a) so that worst -case demand tension load on a single anchor can be computed per the ASCE 7-10 Section 12.4.2.3 LRFD seismic load combinations. The ASCE 7-10 Section 12.4.3.2 LRFD seismic load combinations with overstrength are used to determine the worst -case demand shear load on a single anchor. (We-1-0.67 W Pu:= (0.9 — 0.2 .5E6) • 8 max (PEE YE2 PE2 , PELL) = —32775 lbf V:=Q0 • V E = 12659 lbf Factored shear per anchor Factored tension per anchor The anchors at the combined column control the anchorage design by inspection. The anchor spacing and edge distances at this location are as follows: s:= 14.96 in Tension: Spacing between anchors at combined column Breakout cone is assumed to truncate at half the distance to the next anchor in the both the length and width axes of the VSU. Y1 =14.440 in cal _t := in 2 ca2t 29 +0.5 8.07=33.035 in Xt Ca3t : = = 47.245 in _ in . 2 Half the distance to the next column anchorage location in length axis of VSU Anchor distance to edge of foundation Half the distance to the next column anchorage location in width axis of VSU Shear: Breakout cone is assumed to truncate at the next anchor in the length axis of the VSU. Yl = 28.880 in in Ca 1 _s Xt Ca2s : . 47.245 in n .2 Distance to the next column anchorage location in length axis of VSU Half the distance to the next column anchorage location in width axis of VSU See the following sheet for a sketch of the VSU critical anchorage location and edge distances. Created with PTC Mathrad Fynrecs, P vV mathrari rnm fnr mnrP infnrmptinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 27 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 _ 9J 1 Created with PTC Mathcad Fxnress Se P www mAthcari rnm fnr mnrp infnrrnMinn 1 1 1 1 1 1 1 SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 28 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 The standard anchor holes indicated on the Kardex Remstar drawings, located in Appendix B, allow for a 1/2" diameter anchor. Anchor bolts of this size are inadequate to anchor the VSU's to the proposed foundation per an anchorage analysis performed using the software program Hilti PROFIS, the design results of which are attached. The anchorage design was conducted for the worst -case scenario, at the adjacent columns of the VSU's that are tied together. 7/8" 0 ASTM F1554 Gr. 105 anchors are required per the analysis according to ACI 318-14 Chapter 17 below, and the supplementary calculations below account for the afects of a larger plate washer on the anchorage analysis. By using the plate washer and embedding the anchors a minimum of 24" in the proposed foundation, yielding of the steel anchor bolts can be forced to be the controlling failure mechanism over concrete breakout and pullout due to tension loads, and a ductile failure meeting ACI 318-14 17.2.3.4.3 (a) requirements can be promoted. Design Loads, General Properties, and Strength Reduction Factors: Nua:= 2 • abs (P,L) = 65550 lbf V 2 • abs (V,2) = 25318 lbf fic := 4000 psi fyta := 105 ksi futa:= 125 ksi Osteel_tensiort:= 0.75 steel_shear := 0.65 Oconc_breakoutz= 0.75 Ocone := 0.7 Demand tension on anchors Demand shear on anchors Concrete compressive strength Yield strength of steel anchor Rupture strength of steel anchor Factor for normal -weight concrete per Section 17.2.6 Steel tension strength reduction factor for ductile failure per Section 17.3.3 Steel shear strength reduction factor for ductile failure per Section 17.3.3 Concrete breakout strength reduction factor with supplementary reinforcement per Section 17.3.3 Concrete strength reduction factor per Section 17.3.3 cP.s,ismic := 0.75 Seismic strength reduction factor per Section 17.2.3.4.4 Steel Strength of Anchors in Tension: 1 A„1 := 0.462 in2 Effective cross sectional area of anchor in tension 1 N„uta , 1.9 fyta 125 ksi) =115500 lbf Nominal steel strength of 2 anchors := . Asejv f in tension per Equation 17.4.1.2 Steel strength of anchors in tension with steel increase for ductile failure per Section 17.2.3.4.3a 1 N„':= 1.2 N5a= 138600 lbf omr fv1-mi-1-1,-mr4 ..rne-cacc Cnn mmthrarl rnm fru- mnrca infnrmatinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 29 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 ust:= 0.473 Utilization of nominal steel anchor strength in tension Nsa steel tension • N sa — 86625 lbf N, ONsa Pullout with Plate Washer: in Pw d sleeve= 1 in Abrg 2 1/),p N:=1.0 4 le 2 =8.21 in2 Np:= 2 • 8 Abrg • tc•lbf =525735 lbf UP := Nua = 0.125 Np up < USt OK (1)Np:— conc • Oseismic • Np= 276011 lbf N (/)Np Tension Breakout with Plate Washer: := 24 in ANco:= 9 • hef2 =5184.0 in2 1.5 hef= 36.0 in — Design steel strength of anchors in tension 0.757 < 1.0 OK Utilization of design steel anchor strength in tension Width of square plate washer Diameter of anchor sleeve Bearing area of the plate washer Factor for cracking at service level loads per Section 17.4.3.6 Nominal pullout strength for two anchors per equation 17.4.3.4 Utilization of nominal pullout strength Utilization of steel anchors in tension exceeds that of pullout - ductile failure mechanism Design pullout strength 0.237 < 1.0 .'. OK Utilization of design pullout strength Anchor embedment depth Maximum projected tension breakout cone area Edge distance for maximum projected tension breakout cone area (min( t''5 hef) + min ( 2 2 • 2 min w" + ca3 t 7 1.5 hef S 2 a2 7 15 hef)) =4389 in2 Created with PT('' Mathrari Fynrecc cPP 1h/lA/IA/ mathrarl rnm fnr mnrp infnrmatinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 30 PROJECT: Foundations for Vertical Storage Units CHECKED: AJB DATE: 08/09/2019 := 1.0 Factor for anchor groups loaded eccentrically in tension per Equation 17.4.2.4 7,bd_N:=0.7+ N:=Lo Ocp N • 1.0 kc:= 24 Nb:=16 Aa • 0.3 min c • Ca2t Ca 1.5 hef 3 = 202070 lbf ANC Ncbg:= A c_ ed_ -11-Nco Ito= =0.467 Ncbg ucb<ust • • P- 0.820 Factor for edge effects per Equation 17.4.2.5b Factor for cracking at service level loading per Section 17.4.2.6 Factor for cast -in -place anchors per Section 17.4.2.7 Breakout factor for cast -in -place anchors per Section 17.4.2.2 Nominal tension breakout strength of a single anchor per Equation 17.4.2.2b •Nb•lbf =140354 lbf Nominal tension breakout strength of anchor group per Equation 17.4.2.1b Utilization of nominal tension breakout strength OK Utilization of steel anchors in tension exceeds that of tension breakout - ductile failure mechanism Ncbg: _breakout • cl'seis i • N ONcbg 0.830 < 1.0 = 78949 lbf Design tension breakout strength OK Utilization of design tension breakout strength Steel Strength of Anchors in Shear: A„:= 0.462 in2 Effective cross sectional area of anchor in shear lisa:=. 0.6.2 .Ase_v • min V&A, 1.9 fyta , 125 ksi)= 69300 lbf Steel strength of 2 anchors in shear per Equation 17.5.1.2b (,Ws shear • Vsa. 45045 lbf Vva =0.562 < 1.0 .'. OV,a Design steel strength of anchors in shear OK Utilization of design steel anchor strength in shear Crpatprl with PTC Mthr•Arl Fynrocc SPP MARN nnt-hrrl r m fnr mnt- inforrntinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units Pryout: CPV epg CO = 280707 lbf •K9=196495 lbf Vua =0.129 < 1.0 01 cpg Shear Breakout: ha:= 27 in A:=4.5 cal s2 = 3753 in2 ((2) • min (1.5 cau„ca2 /,:= fief= 24 in da := 0.875 in Occv:=1.0 7 0.3 cca_s /Pedv := min 0.7+ 1.5 cal_s I,bc_v =1-2 11; h,_V := if min ha < 1.5 cal '1 7 / \ 0.2 daj JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 31 CHECKED: AJB DATE: 08/09/2019 Pryout factor per Section 17.5.3.1 Nominal pryout strength of anchor group per Equation 17.5.3.1b Design pryout strength OK Utilization of design pryout strength Concrete foundation depth Maximum projected shear breakout cone area .5 ca", 2743 in2 Shear breakout cone area Load bearing length of anchor in shear per Section 17.5.2.2 Diameter of anchor Factor for anchor groups loaded eccentrically in shear per Equation 17.5.2.5 Factor for edge effects per Equation 17.5.2.6b Factor for cracking at service level loading per Section 17.5.2.7 , 1 =1.267 Factor for concrete depth per Section 17.5.2.8 Aa•ilf,•( _s ) 5 .114=88342 lbf Nominal shear breakout strength of a single anchor per Equation 17.5.2.2a A„ Vchg:= • 6- v• Od cV V e • •vb —98144 lbf vco CPV cbg conc_br cak out • Vcbg= 73608 lbf Vua (I)V cbg =0.344 < 1.0 .'. OK Nominal shear breakout strength of anchor group per Equation 17.5.2.1b Design shear breakout strength Utilization of design shear breakout strength Crated with PTC Mathrarl Fxnrecc SPP vvvvw mathrArl corn for mnno infnrrnAtinn SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT: Foundations for Vertical Storage Units Combined Tension and Shear Steel Anchor Check: 5 5 N ) 3 ON„ JOB: 18391 DESIGNED: EMF DATE: 08/09/2019 32 CHECKED: AJB DATE: 08/09/2019 =1.011 1.0 OK Interaction check per Section R17.6 Combined Tension and Shear Concrete Breakout Check: 5 5 3 3 ( orog ( 17v; = 0.902 < 1.0 OK Interaction check per Section R17.6 0 CrPAtPrl with PTC Mthnd Fynrracc cPP ‘Anivvo rnAthrrl rnm fnr mnr-P infnrmatinn APPENDIX A SAFE MODEL REPORT AND LOADING DIAGRAMS SITTS & HILL ENGINEERS, INC. IRFE License #*13EXNKCVEENHQRA +4 +4- +X -f 4 SAFE Analysis & Design Report Prepared by Sitts Hill Model Name: Proposed Foundation.fdb 5 July 2019 ` ., I ^ ` .�. .�i ^' Proposed Foundabonjdb SAFE 2O16v1G.02-License #°15EXNKCVEENH{}RA Model Definition 05July 2O1Q Model Definition=0 N / �� O | | | Figure 1: Finite element model 2 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 1. Model properties 05 July 2019 Model properties This section provides model properties, including items such as material properties, section properties, and support properties. 1.1. Material properties Table 1: Material Properties 03 - Concrete Table 1: Material Properties 03 - Concrete Malarial U A thiffiNt Fc Ib1ft3 kip/in2 4000Psi 3644.147 0.200000 5.5000E-06 1.5000E+02 5000Psi 4074.281 0.200000 5.5000E-06 1.5000E+02 Table 2: Material Properties 04 - Rebar Table 2: Material Properties 04 - Rebar A615Gr60 E UrillWt Fy Fu 160112 IbM3 kipn2 Win2 29000.000 4.9000E+02 60.000 90.000 4.000 No No 5.000 No No Table 3: Material Properties 02 - Steel Table 3: Material Properties 02 - Steel Material A UnitWt Fy Ful Base Rate kOift2 1/F Ibtft3 kiPrin2 kiPAn2 I 29000.000 0.300000 6.5000E-06 4.9000E+02 36.000 58.000 1.2. Section properties Table 4: Slab Properties 02 - Solid Slabs Table 4: Slab Properties 02 - Solid Slabs Thickness in Base Plate Stiff Base Plate 0.2500 No Existing Slab Slab 5000Psi 7.0000 No Proposed Foundation Mat 4000Psi 27.0000 No Sitts Hill Page 3 of 13 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA a _1 1. Model properties 05 July 2019 1.3. Support properties Table 5: Soil Properties Table 5: Soil Properties SoN Stibgrade Non/NO*. bitt3 Soil 2.5920E+05 Compression Only Sitts Hill Page 4 of 13 t Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 2, Model assignments 05 July 2019 2. Model assignments This section provides model assignments, including assignments to slabs, beams, and joints. 2.1. Slab assignments Table 6: Slab Property Assignments Table 6: Slab Property Assignments Ansa SiabProp 2 Proposed Foundation 5 Existing Slab 7 Base Plate 8 Base Plate 9 Base Plate 10 Base Plate 11 Base Plate 12 Base Plate 13 Base Plate 14 Base Plate 15 Base Plate 16 Base Plate 17 Base Plate 18 Base Plate 19 Base Plate 20 Base Plate 21 Base Plate 22 Base Plate 23 Existing Slab 38 Existing Slab 39 Existing Slab 40 Existing Slab 41 Existing Slab 42 Existing Slab 43 Base Plate 44 Base Plate 45 Base Plate 46 Base Plate 47 Base Plate 48 Base Plate 49 Base Plate 50 Base Plate Table 7: Slab Vertical Offsets Table 7: Slab Vertical Offsets Area 7 0.2500 8 0.2500 9 0.2500 10 0,2500 Sitts Hill Page 5 of 13 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 2. Model assignments 05 July 2019 Table 7: Slab Vertical Offsets 11 12 13 14 15 16 17 18 19 20 21 22 43 44 45 46 47 48 49 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 0.2500 Table 8: Slab Edge Releases Table 8: Slab Edge Releases Are 2 1 Yes Yes 2 2 Yes Yes 2 3 Yes Yes 2 4 Yes Yes 2 5 Yes Yes 2 6 Yes Yes 5 3 Yes Yes 5 4 Yes Yes 23 3 No Yes 38 1 Yes Yes 38 2 Yes Yes 38 3 Yes Yes 38 4 No Yes 39 1 No Yes 39 2 Yes Yes 39 3 Yes Yes 40 1 No Yes 40 3 Yes Yes 40 4 Yes Yes 41 1 Yes Yes 41 2 Yes Yes 41 3 Yes Yes 41 4 Yes Yes 42 1 Yes Yes 42 2 Yes Yes 42 5 Yes Yes 42 6 Yes Yes Sitts Hill Page 6 of 13 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 2. Model assignments 05 July 2019 2.2. Support assignments Table 9: Soil Property Assignments Table 9: Soil Property Assignments Area Ser1Prop 1 2 Soil 5 Soil 23 Soil 38 Soil 39 Soil 40 Soil 41 Soil 42 Soil Table 10: Point Restraint Assignments Table 10: Point Restraint Assignments Uy tir Ry 1 Yes Yes No No No No 2 Yes Yes No No No No 3 Yes Yes No No No No 4 Yes Yes No No No No 7 Yes Yes No No No No 48 Yes Yes No No No No 92 Yes Yes No No No No 94 Yes Yes No No No No 95 Yes Yes No No No No 96 Yes Yes No No No No 101 Yes Yes No No No No 104 Yes Yes No No No No 105 Yes Yes No No No No 116 Yes Yes No No No No 167 Yes Yes No No No No 168 Yes Yes No No No No 169 Yes Yes No No No No Sitts Hill Page 7 of 13 Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 3. Model loading 05 July 2019 3. Model loading This section provides model loading information, including load patterns, load cases, and load combinations. 3.1. Load patterns Table 11: Load Patterns Table 11: Load Patterns Type S uit D DEAD 1.000000 EX+ QUAKE 0.000000 EX- QUAKE 0.000000 EY+ QUAKE 0.000000 EY- QUAKE 0.000000 Table 12: Load Assignments - Surface Loads Table 12: Load Assignments - Surface Loads fair toad A B C b/ftfi ItIft3 ib/ft3 7 7 7 8 8 8 9 9 9 10 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 19 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 EY+ Gravity 96528.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 70475.00 0.0000E+00 0.0000E+00 0.00 EY+ Gravity 96528.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX- Gravity 70475.00 0.0000E+00 0.0000E+00 0.00 EY+ Gravity 96528.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX- Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 EY+ Gravity 96528.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 70475.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX- Gravity 70475.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX- Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 70475.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX- Gravity 70475.00 0.0000E+00 0,0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX- Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 D Gravity 40450.00 0.0000E+00 0.0000E+00 0.00 EX+ Gravity 144244.00 0.0000E+00 0.0000E+00 0.00 EY- Gravity 96528.00 0.0000E+00 0.0000E+00 0.00 Sitts Hill Page 8 of 13 � ^ ^^ �' �' ` ^^ `'' ' Proposed Roundmtion.fdb 3. Model loading O5July 2O19 SAFE 2O1Wv1G]]2-License #°13EXNKCVEENHC}RA Table 12: Load Assignments ' Surface Loads 20 D Gravity 40450.00 O.00OOE+00 V.00OOE+00 0/0 2$ EX+ Gravity 70475,00 O,OOOOs+00 oOOOOE+00 OM 20 Ev' Gravity 98528.00 O.00UOE+00 O.00OOE+00 0l0 21 D Gravity *0*50.00 OMU0E+00 U.U0OOs+00 0.00 21 EX. Gravity 70475.00 OMUOe+Ou U.U08UE+00 OM 21 ev' Gravity 80528.00 0MOOE+00 O.OUOUE+QO OM 22 D Gravity 40450.00 O.o880e+00 n.00oOs+00 0,00 22 EX' Gravity 14*244.00 VDO8OE+00 O.00OUs+VO 0,00 22 EY' Gravity 98528.00 OMOOE+00 O.0000E+00 0,00 48 D Gravity 40450,00 O,O0O0s+00 U.U0Oos+08 0.00 43 EX' Gravity 14424400 0,O00Us+00 U.00OnE+00 0.00 43 EY+ Gravity 101299.00 V,OOUOE+00 8.OUOUE+00 0.00 44 D Gravity 4045000 UOOOOs+00 V,OOOOs+OO 0.00 44 EX- Gravity 70475M 0.UUUUs+00 V.UOUUE+00 UO 44 EY+ Gravity 101288M 0,O000s+00 OV000E+00 0,00 45 n Gravity 40450o0 0,0OUOs+00 o.VOVVE+VO 0.00 45 EX+ Gravity 70475,00 UVVOs+00 OMOnE+VV 0.00 45 EY+ Gravity 1012e9o8 o.o0VVs+00 0-0000E+00 0M 46 D Gravity *0*50,00 o.UOVOs+Uo V.OVOUe+00 0.00 40 EX+ Gravity 144244.00 U,0U00E+00 ODOOVs+Vo OM 48 EY+ Gravity 101299.00 0.VUUOs+00 O.U0O8E+00 UO 47 o Gravity 4045000 O.00UOE+00 U.U000E+00 UO 47 Ex' Gravity 144e44.00 o.0000s+oo u.0000s+oo 0.00 47 Ev' Gravity 101298.00 O.O0O0E+00 8.00OOe+00 0,00 48 o Gravity 40450.00 n.Oonos+nn o.0000E+oo 0,00 48 sx, Gravity 70475u0 U000E+00 O.Oo00E+00 0V0 48 Ev' Gravity 101299Vo O.00OUE+OO o.um0E+00 0.00 49 o Gravity 48450.00 V.UUOUs+OU o.on0Os+00 OM 49 EX+ Gravity 70475.00 V,OOUOE+OU 0000OE+00 0,00 49 EY- Gravity 101299o0 U.OUUOe+oO oM00E+00 0,00 50 m Gravity *0450,00 o,Oouos+VO UMnoE+00 0,00 50 EX+ Gravity 1442*4.08 O0000s+OO 0-0000E+00 uon 50 sY' Gravity 1o12nouo Vo00Os+nO o�nonVs+VV O�00 _ ][able 13: Load Assignments ~ Point Loads Tablo1V: Load Assignments 'Point Loads Point LoadlPam Fn Fy Fgrav } mp kip mw 52 EX+ 6.330 0000 0-000 sz Ex- '6.330 0.000 '38-236 52 EY+ OMn 0MO 0.000 oz sv- 0.000 '*.uuo '25�587 nn EX+ 6330 0.000 0.000 53 sx. '0330 0.000 '18V81 sa EY+ 0.000 *.auo 000O 53 EY' 0,000 '8J30 '25�*87 54 EX+ 6.338 000n '1a681 54 EX, *.aoo 0.000 VoVV 54 EY+ 0,000 o.»zn 0.000 s^ EY- VM0 '6M0 '25,587 55 EX+ 6.330 0.080 '38,230 .' ^' I ^ ^ � ` . `' ' " l `^ " `^ '^ 7 PnoposedFnundmdon.hjb SAFE 2016v10.0.2'License #°13EXNKCVEENH(]RA 3. Model loading U5July 2O10 Table 13: Load Assignments ' Point Loads POW Lomdpat FX Fy Fgrm*kip kip kip 55 sX- �330 0.000 0.00 55 EY+ 0.000 8.330 0.000 en EY' 0.000 '6.330 '25.587 58 Ex+ 6330 0,000 0,000 ns sx' '0.330 8.000 '30�238 58 EY+ 0.000 8.330 OMn 56 EY' 0.000 -8.330 V»nV 57 Ex+ 6.330 UVVV 0MO 57 EX- '6.330 0.000 '18,601 57 EY+ 0,000 6.330 0.000 57 rY' 0,000 &338 8Mo 58 sx+ 6330 0.000 -18.601 58 EX- '0.330 0,000 0,000 58 EY+ OVOO 6330 8.000 sa sY- oouo -0.330 0.000 59 Ex+ 6,330 0.000 '38236 59 sx' 'a.oao 0.000 VoOV 58 EY+ 0.000 8.330 0,000 58 eY- 0.000 '6.330 0000 60 ex+ 8.330 0.000 OM0 80 Ex' -8.330 ODOO '38238 80 EY+ 0Mo 8330 OMO 80 sv' 0.008 '6.330 0,000 61 sx+ 6330 0.000 0,000 61 sx' '6330 0000 '18,681 61 EY+ 0V00 6.330 0,000 61 Ev- 0.800 '6330 ooOn 82 EX+ 6.330 ooOO 1&681 62 sx' -6,330 0.000 0.000 82 EY+ 0.000 8.330 0,000 82 sv' 0.000 '8.330 0,000 63 sx+ 6.330 0o00 'nozoo 63 sx. '6.330 0,000 0,000 63 EY+ 0.000 8.330 0,000 63 sv' 0.000 '8.330 0V00 64 EX+ e.330 8.000 0.000 V* Ex' '&330 0.000 '38236 84 EY+ 0,000 6.330 '25.587 64 EY' ouoo '8.330 0,000 es sx+ &noo 0000 0.000 so sx' '6MV oMO '1&681 65 EY+ 0.000 6.330 'zo.sur 65 EY' O000 '8.330 0,000 66 sx+ 6330 0.000 '18a81 66 Ex' '&330 0,000 0,000 oa EY+ 0.000 6.330 '25,587 68 sv' 0.008 '6.330 uMo 67 sx+ 6.330 0.000 '38236 ur Ex. '6330 0.000 0000 67 EY+ 0.000 Gono '25.587 sr sY' 0.000 '8.330 OM0 202 ex+ '6330 OoOO 'oa.zns 202 sx' 6.330 ooVn 0,000 202 EY+ 0.000 *.330 0.000 ., Sitts Hill Page 1Oof13 ^ ` `^ ' ^ PnzpooedFoundadon.hjb SAFE 2U1Sv16.O.2'License #^13EXNKCVEENHOFA 3. Model loading U5July 2010 Table 13: Load Assignments - Point Loads Pwwit Kowat � - Fx '"' Fy Fgwwv _kl�p_ kip kip 202 sY' 0.000 '6.330 a8�852 203 sx+ '&330 0.000 '18.681 203 sx' 6,330 UMV UMU 203 EY+ UMO 8330 0.000 aoa sY' 0.000 '6330 -26�852 204 Ex+ '&330 0,000 0,000 204 EX' 6.330 0.000 '1&681 20* EY+ 0.000 0.330 OMU 204 EY' 0.000 -6.380 '26852 205 sx+ '8.330 0.000 0,000 205 ex' 8.320 0.000 '38288 205 EY+ oVoO 6.330 0,000 205 Ev' 0,000 '8,330 '26�852 208 Ex+ '0.330 0.000 '38.230 206 s* 6.330 0.000 0.000 208 EY+ oMV 8,330 '20.852 206 sY' 0.000 '8.330 0,000 207 Ex+ '6.330 0.000 1&681 207 sx' 0,330 UVuV 0,000 207 EY+ 0.000 8.330 -20,852 207 sY' ouuu '6330 UoOo 208 [x+ '6.330 0,000 O40O 208 EX- 6338 0.000 18081 208 EY+ 0,000 6.330 '26852 oVn EY' 0000 -6330 0,000 208 sx+ '6.:30 0.000 0.000 209 EX- &330 0.000 'xe.zno 209 EY+ 0.000 0.330 '2&852 209 sv' noou 'oaon noOO ` 3.2. u����� y mK cases ^ ., l ^__j Table 14: Load Cases 02 - Static Table 14: Load Cases 02 - Static blimallCOW ATM* mOWOMOTm o Zero Linear 0�61D+0IEv+ Zero Allow Uplift 0.000010 0�6D+o7sv' Zero Allow Uplift 0.000018 o+Orex+ zenm Allow Uplift 0u00010 D+07Ex- Zv,v Allow Uplift 0.000010 D+orEY+ zpm Allow Uplift 0.000010 D+o.rEv' zvm Allow Uplift 0.000010 0,6D+0Jcx+ Zero Allow Uplift 0.000010 0,6D+0.7sx. zom Allow Uplift 0V00010 Ex+ Zero Linear Ex- 7,nv Linear EY+ zom Linear eY' zono Linear Sitts Hill Page 11 uf13 `' " ^' `^ ` Pr000sedFoundmUon.fdb SAFE 2O18v10.O.2'License #°13EXNKCVEENH<]RA 3. Model loading O5July 2O1S Table 15: Load Cases 06-Loads Applied Table 15: Load Cases 06 - Loads Applied LoadCase Lo"Wat D O6D+O.7sv+ 0,6D+0JEY+ OW+0.7EY' U.OD+U7EY- D+O.7ex+ D+O7EX+ D+O7EX- D+O.7E>- O+07EY+ o+V.rsY+ D+U.7sv' D+UJEY' 0.6D+OJEX+ O.oO+OJEx+ OW+O7EX, K0+V71EX- EX+ EX- Ev+ s,' �� .�. �~oa^� � � .�' �� combinations ` ^ Table 16: Load Combinations 1MOOUO U0OOUO MO000o 0,600000 0,700000 1.000000 0.700000 1,000000 0.700000 1,000000 0.700000 ,.VOVV0V 0.700000 UMVOVU 0700000 0.600000 0.700000 1.000000 1,000000 1.000000 1.000000 Table /6: Load Combinations (0.9-02Sds)D+EX+ (0.8�.2Sds)D*EX+ <0,9'02sus>o+Ex' (o.9'o,znuu)u~sX. (o.*V2Soo}o+sv+ (0.*02Sus)o+sY+ (0y'02aux)o+cY' (O.9-02Su,)o+sv- (,2+02Sus)o+sx+ (1.2+0.23uo)D+sx+ (12+02Sc*)o+sx' (1.2+V23uo)a+sx' (12~V.23uo)D+s,+ (12+023uv)o+sv+ (12+02Sos)o+Ev' D B* EX- cY+ D EY- D EX+ EX- 0 EY+ u eY- Linear Add Linear Add Linear Add Linear Add Linear Add Linear Add Linear Add Linear Add Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No No No No No No No No No SittsHiU Page 12 of 13 J Proposed Foundation.fdb SAFE 2016 v16.0.2 - License #*13EXNKCVEENHQRA 4. Design summary 05 July 2019 4. Design summary This section provides design information for beams, strips, and punching checks. 4.1. Preferences Table 17: Design Preferences 01 - Resistance Factors Table 17: Design Preferences 01 - Resistance Factors Pf rTen = PhiComp PhiShear 0.900000 0.650000 0.750000 Table 18: Design Preferences 02 - Rebar Cover - Slabs Table 18: Design Preferences 02 - Rebar Cover - Slabs CoverTop CoverBot BarSize imerLayer PTCGSTop PTCGSBotE PTCGSBotll Slat>T xt in 2.9375 3.9375 #6 B 1.0000 1.7500 1.0000 Two Way Sitts Hill Page 13 of 13 ^ ' ' � - ^ � . ^ l ^ Proposed Foundation SAFE2O1G 18.0.2 Slab Surface Loading inGravity Direction (0) [Ib/ft2] Proposed Foundation SAFE 2016 16.0.2 Point Loads (EX+) [kip, kip-ft] 7/5/2019 8:28 AM kip - ft Proposed Foundation SAFE 2016 16.0.2 Slab Surface Loading in Gravity Direction (EX+) [Ib/ft2] 7/5/2019 8:27 AM kip - ft Proposed Foundation SAFE 2016 16.0.2 Point Loads (EX-) [kip, kip-ft] 7/5/2019 8:29 AM kip-ft Proposed Foundation ^ ' I ' ' ., -` .-1 -^ . -^ GAFE2U1G 16.0.2 .' Slab Surface Loading inGravity Direction (EX-) Ob/ft2] Proposed Foundation SAFE 2016 16.0.2 Point Loads (EY+) [kip, kip-ft] 7/5/2019 8:36 AM kip - ft ' l Proposed Foundation ) I � ^ � �' ` � SAFE 2O1G16�.2 Slab Surface Loading inGravity Direction (EY+) Ob/ft2 kip 'ft ^^ Proposed Foundation SAFE 2016 16.0.2 Point Loads (EY-) [kip, kip-ft] 7/5/2019 8:37 AM kip - ft Proposed Foundation SAFE 2O1G18.O-2 Slab Surface Loading in Gravity Direction (EY-) [lb/ft2j Np-ft um • OM WWI w APPENDIX A KARDEX REMSTAR DOCUMENTS SITTS & HILL ENGINEERS, INC. wit • Supporting contact surface 8 x 140 crn2 Personal protection light curtain holder or cable duct for multiple access openings Boeing Seattle LAYOUT PLAN HO-500 2450 mm x 863.6 mm x 8050 mm (96.46 in. x 34 in. x 26 feet, 4.93 inches) power supply 2400 mm (94.49 in. Hole for floor anchoring 0 14 mm (0.55") Access table t) Unit Width: 2780 mm (109.45 in.) 205 mm (6.07) X = 528/ mm (20.81 in.) Y 1606.5 mm (63.25 in.) Personal protecion light curtain holder 205 mm (8.01") Unit Depth: 3073 mm (120.98 in.) 40 This layout does not account for extraction table dimensions, if chosen on POF; only the basic access opening. - The weight load is transferred to the supporting contact surfaces at the base frame via eight load profiles. The supporting surfaces are the contact surface for the complete machine. - (Total) Supporting Contact Surface: 173:6 in.z (1120 cm) - X: Spacing of outer load profiles - Y: Spacing of inner load profiles The evenness of the floor surface, on which quality assured products are installed, must be within the admissible tolerances: Up to 10 meter unit height, distance = 12mm (0.47 in.) Unit must be anchored to the foundation - The front edge of the access table and the personal protection light curtain protrude the access opening by 40 mm (1.57") Specifications for Shuttle XP HD-500 2450 mm x 863,6 mm x 8050 mm (96.46 in. x 34 in. x 26 feet, 4.93 inches) Yoe No Quantity of Units . 3 Overall Unit Height : 26 feet, 4.93 inches Required Room Height 26 feet, 5.76 inches The required room height ( unit height + 20mm /0.79') is the absolute minimum measure. Possible floor/ ceiling unevenness and slope must be considered therein. Overall Unit Width 109.45 in. Overall Unit Depth . 120.98 in. Shuttle Weight . 7,250 Pounds Empty without Trays, Product, etc. Weight of Trays . 8,311 Pounds (Average per Unit) Approx. Weight Empty w/Trays . 15,561 Pounds (Average per Unit) Approximate Weight Fully Loaded as Configured . 85,778 Pounds (Average per Unit) Quantity Load Per Tray (lb! Tray Type Clear Width Clear Dep Avg./Unit Total/Order Maximum Light Trays . 96.46 in. 34 in. Medium Trays : 96.46 in. 34 in. Heavy Trays : 96.46 in. 34 in. 'Medium X Type 2 Trays : 47.74in. x 2 32.27 in. 'Medium Universal S Type 2 Trays . x 2 33.72 in. Medium XL Type 1 Deep Trays : 96.46 in. 33,6 in. Medium XXL Universal Trays . 96,46 in. 33.6 in. `Medium Universal RS Type 2 Trays . x 2 33.72 in. 'Medium XL Type 2 Deep Trays . 47.74 in. x 2 33.6 in. Heavy XL Type 1 Deep Trays : 96.46 in. 33.6 in. "Heavy XL Type 2 Deep Trays : 47.74 in. x 2 x 33.6 in. Frame R XXL Trays . 95.08 in. x 33.6 in. Heavy 5 XXL Trays : 96,06 in. x 34 in. Medium S XXL Trays . 95.08 in. x 33.6 in. Medium Universal R Type 2 Trays . x 2 x 33.72 in. Medium Universal R Type 3 Trays : 51.85 in. x 2, 52.16 in. x 1 x 33.72 in. 0 0 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 195 0 0 0 0 0 0 0 0 0 0 0 0 0 507 794 1080 *divided by a reinforcement bar which is adjustable on 50mm (1.97") centers up to 200mm (7.87") from renter of tray, left or right Minimum Tray Spacing . $ Maximum Tray Spacing : 29.53 Inches Maximum Product Height : 28.74 inches (730mm) Clearance Required Above Product : 0.79 Inches Shelf Rails (tray supports) : 264 Storage Locations Possible : 528 Maximum Unit Capacity . 147,708 Pounds Unit Capacity after tray weight deducted: 144938 Pounds Lifting Speed : 157.50 Lifting Speed if Extractor is w/o a Tray : 246.05 Extractor Speed : 23.62 ft./min. ft./min. in./sec. Pick Performance (Average Qty.) : 101 Trays/hour (does not consider operator picking time) IR Complete Cycle (Storage + Retrieval) Single Cycle (Tray Retrieval only) Not Average Access Time : 35.46 Seconds 16.73 Seconds Maximum Access Time : 44.82 Seconds 20.41 Seconds w Calculation of access times is based on: 1) Speed adjustment lift (vertical) at 100%; extractor (horizontal) at 100%. Note: 100% 4) Weight management : Activate weight ma extractor speed is not recommended for some storage goods. All delivered units hove a pre -defined setting of 70%. 2) Shutter door update access times above is set to closed during lift movement, i.e. tray positioned in access opening is in'fingerhold.' Note: This setting is only possible with rimtunits equipped with 1 access opening.With the setting"always closed," the access times will increase by6 seconds. 3)Options Q ACTIVATE (Adds 5 seconds to access time) � Y "' P chosen on POF, such as automatic extraction will affect times outlined above. • With time -critical units (e.g. high performance order picking units or robot handling with cycle times) a prior consultation with the factory is recommended. e i rr MR Power . Maximum Power Consumption . Full Load Amp (FLA) . Max. Circuit Breaker Rating for Supply (Delayed) . 480 Volts/3"/PE 8.6 kVA 14.2 Amp Per Machine 15 Amp Per Machine Color Load Profiles and Panels : RAL 5015 Sky Blue /RAL 7035 Light Gray Shelf Rail Panel Exteriors : RAL 7035 Light Gray Side Service Panels : One side Swing / one side Fixed Tooth Belt Drive : Yes Safety Shutter Door System : Yes Control Type : Controls 3000 Operator Panel OP Logicontrol Location : Inside Overhead Center/access Access Ready Lights . No Confirmation Bar : Yes Transport Cart : No Crane and Support Frame : No Extraction Table : No External PS/2 Interface : No Vertical Photocells to Monitor Extractor Column : Yes ESD Equipped Trays : No Transaction Information Center : Yes Light Pointer : Yes LED SPOT, 40 mm dia. Position Indicator Light Bar : No Storage/Surface Area Offered : 1,481 Gross Cube ; 989 Useable Cube when Trays installed : 891 Avg. Sq. Ft. of Surface Area Provided per Shuttle Cubic Ft. per Shuttle Cubic Ft. per Shuttle, 713 Cubic Feet @ 80% Utilization Printed 2/21/2018 XP POF Version 8 , 1-2018 Boeing Seattle FLOOR LOADING n n n n li n nI Shuttle XP HD-500 2450 mm x 863.6 mm x 8050 mm (96.46 in, x 34 in. x 26 feet, 4.93 inches) Information provided below 1s per unit (when more than 1 unit, trays ore divided by # of units for an average/unit) 'The floor loading calculations comply with the General Quality Assurance and Test Regulations for Storage and Factory Equipment, RAL-RG 614 Surface pressure: The customer must ensure and should guarantee the floor has sufficient capacity to absorb the surface pressure. Floor load -bearing capacity: The customer must ensure that the floor has sufficient capacity to absorb all loads imposed by the equipment. The customer must provide the KardexRemstar representative with all information regarding present and future room conditions. If no other information is provided, you can proceed an the assumption that a minimum surface pressure of of 5 N/mm2 (725.19 psi) is acceptable. Maximum surface pressure: Unit deadweight - Max- bad (gross) - (Bearing surface = 14000) amax. : mLGT merutto = mG„. x 9.81 m/s' _ FFGes. 8 z 14000 mm' Maximum surface pressure / PSIs' amax. x 145.04 3289 kg. 67000 kg. 70289 kg. 689532 N 6.16 N/mm2 893,48 psi Actual occuring surface pressure: FFGes./tat.; = Attual load per unit [Nj stat. = Actual surface pressure (N/mm'] A = Bearing surface (=14,000 mm') amin.. = Assuming minimum surface pressure of floor [N/mm'] FFGesltat 8xA amin. 2 atat. Unit dead weight mlar= 3289 kg Total Tray dead weight - [n (# Trays)'x dead cat. each] "" 3770 kg 6 Max tray ad - 175,o. tap Trays) x Load each] 31850 kg. mGes,tat = MLGT + (MT + Mzw•) FFo„_: mGes.tat.x 9.81 m/s' FFGes. atat.. 8 x 14000 mm' Actual surface pressure / PSl atat. x 145.04 38909 kg. 381694 N 3.41 N/mm2 494.29 psi Max. required floor load capacity: MGesmax• = Mae. Total Weight (kg.) mLGrl = Unit dead weight (kg.) mane., = Max, gross load (kg.) Max. total load - 1CN�esma,. MLGT + marvtto ▪ 70289 kg, Calculation of maximum floor load bearing capacity: Pmhs, 1 Pmax. Load per unit (N) AGarei ▪ = Unit base (m'] UW = Unit width (m) UD = Unit depth [m) Pm = Max. floor load bearing capacity (N/m'] Pm.. = Assuming min. floor load capacity [N/m'] Maximum Load per unit - Unit base [m9 - x 9.81 m/s' AGerat UW x UD FFGes. AGerat 689532 N 8.54 m' 80741 N/m' 81 kN/m2 Maximum Floor Load Bearing Capacity x .00014504 a11.11 psi Actual required floor load bearing capacity: MGestst.! = Actual Total Weight (kg.) MLGT' = Unit dead weight (kg.) mania] = Max, gross load (kg.) Actual total load MGes = MLGr + n x (MT + 38909 kg. Calculation of actual floor load bearing capacity: Pmtr. Z Pmea. FFGes/,a, = Actual Load per unit (N) AG.rai = Unit base [m1 UW = Unit width [m) UD = Unit depth [m] f Plat. = Actual floor load bearing capacity [N/m'] Pm;o. = Assuming min. floor load capacity [N/m'] Actual Load per unit - FFGe;.: mGes9.81 m/s' 381694 N Kardex Remstar, LLC Date Printed 12/21/2018 8.54 m' Unit base [m'] - drat UW x UD FFGes./tat. drat ang YCapamtyr/ PSI,3 p t sjjj 44695 N/m' 45 kN/m2 • Kardex Remstar, LLC Date Printed 12/21/2018 City of Tukwila Department of Community Development 1/2/2020 MARTIN PROBST • PO BOX 3707; M/C: 46-208 SEATTLE, WA 98124 RE: Permit No. DI9-0264 BOEING #2-10 1135 S WEBSTER ST BLDG 2-010 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical. Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/24/2020. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/24/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ."0 Bill Rambo Permit Technician File No: D19-0264 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 9ERMIT MORD COPY (:t PLAN REVIEW/ROUTES G SLIP PERMIT NUMBER: D19-0264 PROJECT NAME: BOEING #2-10 SITE ADDRESS: 1135 S WEBSTER ST Original Plan Submittal Response to Correction Letter # DATE: 11/15/19 Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: Pr.\ Building Division Public Works Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) Planning Division Permit Coordinator DATE: 11/19/19 r Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues DUE DATE: 12/17/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire Ping 0 PW D Staff Initials: 12/18/2013 EiMT td0 RD COP( PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0264 PROJECT NAME: BOEING - #2-10 SITE ADDRESS: 8123 E MARGINAL WAY S X Original Plan Submittal Revision # Response to Correction Letter # DATE: 08/15/19 before Permit Issued Revision # after Permit Issued DEPARTMENTS: C Building Division 101- `61 Public Works PPreventiont* (61611 ire P%ing 'division Structural Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 08/20/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required E (corrections entered in Reviews) DUE DATE: 09/17/2019 Approved with Conditions Denied (ie: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 0 Ping LJ PW 0 Staff Initials: 12/18/2013 PROJECT NAME: SITE ADDRESS: PERMIT NO: 1tqo 21,11 ORIGINAL ISSUE DATE: B-241 9 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITI LS ISSUED DATE STAFF INITIALS I kS 1LWL Summary of Revision: 0‘ 4 v" t 4 -e-fiy— Received by: ,--_,/e'• REVISION REVISION DATE RECEIVED STAFF ISSUED DATE STAFF NO. INITIALS INITIALS Summary of Revision: Received by: (please print) REVISION NO. (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www,TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11/4/2019 Plan Check/Permit Number: D19-0264 El] Response to Incomplete Letter # Ej Response to Correction Letter # Revision # 01 after Permit is Issued El Revision requested by a City Building Inspector or Plans Examiner LJ Deferred Submittal # Project Name: 2-10 VERTICAL STORAGE UNITS Project Address: 1135 S WEBSTER ST Contact Person: MARTIN PROBST Summary of Revision: Install embed plates and revise anchoring plans. Phone Number: 206-852-4985 RECEIVED CITY OF TUKWILA NOV 1 5 2019 PERMIT CENTER Sheet Number(s): GO, GI, 1S64R, I S64, S610, and S6I1 "Cloud" or highlight all areas of revision including date o rev ion Received at the City of Tukwila Permit Center by: 12--- Entered in TRAKiT on WAPermit Center \Templatefforms\ Revision Submittal Formdec Revised: August 2015 H °Inc I spaiiol Go la act Safety & Health Claims & Insurance hington State Department of abor & industries AZ Index Help My IM Workplace Rights Trades & Licensing WASHINGTON PATRIOT CONST LLC Owner or tradesperson Principals STANTON, JARED M, PARTNER/MEMBER RUTHERFORD, DAVID D, PARTNER/MEMBER TRAUGUTT, MICHAEL DAVID, MANAGER WADE PERROW CONSTRUCTION LLC, PARTNER/MEMBER (End: 11/21/2012) MCKINNEY, DANIEL G, MANAGER (End: 11/21/2012) PERROW, WADE HAMPTON, MANAGER (End: 11/21/2012) PERROW, ELIZABETH ANNE, MANAGER (End: 11/21/2012) Doing business as WASHINGTON PATRIOT CONST LLC WA UBI No, 602 932 517 10421 BURNHAM DR NW SUITE 5A GIG HARBOR, WA 98332 253-853-2304 PIERCE County Business type Limited Liability Company Certifications & Endorsements License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WASHIPC906BJ Effective — expiration 01/11/2010— 01/11/2020 Bond Safeco Ins Co of America Bond account no. 69s012661 $12,000.00 Received by L&I Effective date 05/11/2012 04/20/2012 Expiration date Until Canceled Insurance Valley Forge Ins Co $1,000,000,00 Policy no. Help us improve BOEING COMMERCIAL AIRPLANES PLANT 2 2-10 BUILDING FOUNDATIONS FOR VERTICAL STORAGE UNITS LOCATION y TO EVERL I MUKILTEO EVERLII ��7 LYNN \EDMOND 1 r IOD 1 BOTHELL 0 99 '/, i ' � KIR LAND REPMOND ``- ' 9 o 'TTLE 1 ¢ BE EVUE /' 1 I BCS I -/ ISSAQUAH I --`- S. PAR PROJECT SITE DU AM SH CNT ' RENTON I I f , DESs, •IlkRENTON OIN r SCALE: NONE �, �, �, 1�� 5 ° KENT oAUBURN I 7 i TO T M AUBURN I REVISION BY APPROVED DATE SYM VICINITY MAP ,,, ,,, oQ10 i �� `le/ ,2� I� SCALE: NONE 2-14 v> 9� Sy �� 9l * SITE PROJECT REVISION BY APPROVED DATE FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 SITTS BKL 11.04.19 CODE SUMMARY BUILDING CODE: IBC 2015 EDITION AS ADOPTED BY THE CITY OF TUKWILA SEISMIC ZONE: USE GROUP 1, IMPORTANCE FACTOR 1, SEISMIC DESIGN CATEGORY D SITE CLASS D. OCCUPANCY GROUP: Fl - FACTORY S1 - STORAGE, AIRCRAFT TIRES S2 - STORAGE, AIRCRAFT TOOLS CONSTRUCTION TYPE: TOTAL BUILDING AREA: CONSTRUCTION AREA: BUILDING HEIGHT: STORIES: III - B 406,979 SQ FT 649 SQ FT 46 FT. ONE PROJECT SUMMARY DESCRIPTION OF WORK: INSTALL FOUNDATIONS AND ANCHORS TO SUPPORT NEW VERTICAL STORAGE UNITS. PROJECT COST: CONTRACTOR: SITE ADDRESS: OWNER: OWNER CONTACT: $35,000.00 1135 SOUTH WEBSTER STREET SEATTLE, WA. BOEING COMMERCIAL AIRPLANES P.O. BOX 3707, M/S: 1 W-10 SEATTLE, WA. 98124-2207 NAWAB HABIBURAHMAN (425) 326-0685 KING COUNTY PARCEL NO. 0022000005 SEATTLE g,LAsustEgrov”° it ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. Kamla CHECKED A. Boileau ENGINEER A. Boileau CHECKED APPROVED APPROVED flECE VET) CITY OF TGKWtL NOV 15 2019 E MIT CE TE DATE 05.29.19 05.29.19 05.29.19 TITLE GENERAL SEPARATE PERMIT RE9UIRED FOR: i M clirnrric.Sl f�le�tric:x�l Piumbin Piping City of Tukwila LDiNG D1V'ISION LEGAL DESCRIPTION ARV; 002200-0005 ALL BLOCKS 1, 3, 4, 5 AND 6, ABRAM'S ADDITION TO SOUTH SEATTLE, ACCORDING TO THE PLAT THEREOFRECORDED IN VOLUME 11 OF PLATS, PAGE 30, IN KING COUNTY, WASHINGTON. EXCEPT THAT PORTION OF BLOCK 3 DESCRIBED AS FOLLOWS: COMMENCING AT THE CENTERLINE INTERSECTION OF 12TH AVENUE SOUTH AND SOUTH AUSTIN STREET, THENCE SOUTH 88'20'05" EAST ALONG THE CENTERLINE OF SOUTH AUSTIN STREET 89.80 FEET. THENCE SOUTH O1'39'55" WEST 12.00 FEET TO THE SOUTH MARGIN OF SOUTH AUSTIN STREET AND THE TRUE POINT OF BEGINNING: THENCE SOUTH 02'17'42"WEST 23.09 FEET; THENCE SOUTH 42'20'44" WEST 45.24 FEET; THENCE NORTH 48'22'04"WEST 89.36 FEET TO THE SOUTH MARGIN OF SOUTH AUSTIN STREET; THENCE SOUTH 88'20'05" EAST 98.23 FEET ALONG SAID MARGIN TO THE TRUE POINT OF BEGINNING AND EXCEPT LOTS 1, 7 AND 8, BLOCK 6; AND EXCEPT THAT PORTION OF LOT 5, BLOCK 6; CONDEMNED IN KING COUNTY SUPERIOR COURT CASE NUMBER 102874 FOR EAST MARGINAL WAY; ALL OF BLOCKS 32, 33, 34, 41, 42, 43 AND 44, RIVER PARK ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 7 OF PLATS, PAGE 41, IN KING COUNTY, WASHINGTON; EXCEPT THOSE PORTIONS OF BLOCKS 32, 33, 34 AND 41 LYING WITHIN COMMERCIAL WATERWAY NO. 1 (ALSO KNOWN AS DUWAMISH WATERWAY) EXCEPT LOTS 7 AND 8, BLOCK 43; TOGETHER WITH THAT PORTION OF SECTION 29, TOWNSHIP 24 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON LYING NORTHEASTERLY OF THE RIGHT OF WAY OF COMMERCIAL WATERWAY NO. 1, AND LYING SOUTHEASTERLY OF THE MEDIAN LINE OF REVISED SLIP NO.4 AS DESCRIBED IN INSTRUMENT RECORDED UNDER RECORDING NUMBER 4477037 AND LYING SOUTHWESTERLY OF A LINE BEGINNING AT THE INTERSECTION OF THE SOUTH LINE OF LOT 7, BLOCK 43, RIVER PARK, PROJECTED WESTERLY WITH THE SOUTHEASTERLY MARGIN OF SAID SLIP NO. 4 AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT NO. 1 AND AS SHOWN ON THE MAP OF THE DISTRICT PREPARED BY ITS CHIEF ENGINEER IN 1916. THENCE NORTHWESTERLY, PERPENDICULAR TO THE NORTHWESTERLY MARGIN OF VACATED RIVERSIDE AVENUE AS PLATTED IN SAID RIVER PARK TO AN INTERSECTION WITH SAID MEDIAN LINE; ALL OF BLOCKS 1, 2, 3, 4 AND 5, EAST SOUTH PARK, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 14 OF PLATS, PAGE 13, IN KING COUNTY, WASHINGTON; EXCEPT THOSE PORTIONS OF BLOCKS 2, 3, 4 AND 5 LYING WITHIN COMMERCIAL WATER WAY NO. 1 (ALSO KNOWN AS DUWAMISH WATERWAY) EXCEPT THOSE PORTIONS OF BLOCKS I AND 4 CONVEYED TO KING COUNTY BY DEEDS RECORDED UNDER RECORDING NUMBERS 2547379, 2556876, 2556877 AND 2557326; EXCEPT THOSE PORTIONS OF BLOCKS 4 AND 5 LYING EASTERLY OF 16TH AVENUE SOUTH AS CONVEYED TO KING COUNTY BY DEED RECORDED UNDER RECORDING NUMBERS 2547379, 2556876, 2556877, 2557326 AND 2559383; TOGETHER WITH THAT PORTION OF GOVERNMENT LOT 1, SECTION 32, TOWNSHIP 24 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHWEST CORNER OF LOT 17, BLOCK 2, SAID PLAT OF EAST SOUTH PARK; THENCE NORTH 89'4'26" WEST ALONG THE LINE BETWEEN SECTIONS 29 AND 32 IN SAID TOWNSHIP AND RANGE A DISTANCE OF 70.743 FEET TO A POINT BEING THE INTERSECTION OF SAID SECTION LINE WITH THE NORTHEASTERLY RIGHT OF WAY UNE OF COMMERCIAL WATERWAY NO 1; THENCE SOUTH 49'00'00"EAST ALONG THE SAID NORTHEASTERLY RIGHT OF WAY LINE A DISTANCE OF 92.945 FEET MORE OR LESS TO AN INTERSECTION WITH THE WEST LINE OF SAID LOT 17; THENCE NORTH O'33'43" EAST ALONG SAID WEST LINE A DISTANCE OF 59.837 FEET MORE OR LESS TO THE POINT OF BEGINNING. A PARCEL OF LAND IN GOVERNMENT LOT 13, SECTION 29, TOWNSHIP 24 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON , AND IN THE PLAT OF EAST SOUTH PARK, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 14 OF PLATS, PAGE 13, IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING ON THE NORTH LINE OF SAID SECTION 32 AT ITS INTERSECTION WITH THE WEST UNE OF 16TH AVENUE SOUTH AND BEING 64.86 FEET, MORE OR LESS WEST OF THE NORTHEAST CORNER OF THEREOF; THENCE NORTHERLY ALONG THE WEST MARGIN OF 16TH AVENUE SOUTH TO A LINE WHICH IS PARALLEL TO AND 419 FEET NORTHERLY OF THE SOUTH LINE OF SAID GOVERNMENT LOT 13; THENCE NORTH 89'16'44"WEST ALONG SAID LINE 100 FEET; THENCE NORTH O'49'03"EAST ALONG A LINE PARALLEL TO THE WESTERLY MARGIN OF 16TH AVENUE SOUTH 123.11 FEET; THENCE NORTH 49'00'30" WEST 120 FEET; THENCE NORTH 89' 16'44"WEST 95 FEET; THENCE NORTH 49'00'30"WEST 25 FEET, MORE OR LESS TO THE EAST MARGIN OF 14TH AVENUE SOUTH THENCE WEST ALONG THE NORTH LINE OF THAT PORTION OF 14TH AVENUE SOUTH VACATED BY CITY OF SEATTLE ORDINANCE NUMBER 81046 BEING 637.11 FEET NORTH FROM THE SOUTH LINE OF SAID GOVERNMENT LOT 13 TO THE WESTERLY MARGIN OF 14TH AVENUE SOUTH; THENCE NORTHERLY ALONG SAID WESTERLY MARGIN AND SAID MARGIN EXTENDED TO THE CENTERLINE OF VACATED WHIPPLE STREET; THENCE SOUTHWESTERLY ALONG SAID CENTERLINE TO THE WEST LINE OF SAID GOVERNMENT LOT 13; THENCE SOUTHERLY ALONG SAID WEST LINE TO THE NORTHEASTERLY LINE OF THE DUWAMISH WATERWAY; THENCE SOUTH 49'00'00" EAST ALONG SAID NORTHEASTERLY LINE 496.14 FEET TO THE SOUTH LINE OF SAID GOVERNMENT LOT; THENCE EAST ALONG THE SOUTH LINE TO THE POINT OF BEGINNING; EXCEPT THAT PORTION DESCRIBED AS FOLLOWS: BEGINNING AT A POINT AT THE INTERSECTION OF THE NORTH LINE OF THE SOUTH 419 FEET OF SAID GOVERNMENT LOT 13 WITH THE WESTERLY MARGIN OF 16TH AVENUE SOUTH; THENCE NORTH 89'16'44"WEST 100 FEET; THENCE SOUTHEASTERLY ALONG A CURVE TO THE LEFT THE RADIUS OF WHICH BEARS NORTH 65'27'21"EAST 100 FEET TO THE WESTERLY MARGIN OF SAID 16TH AVENUE SOUTH; THENCE NORTHERLY 55 FEET TO THE BEGINNING; THAT PORTION OF THE EASTERLY 594 FEET OF GOVERNMENT LOT 13, SECTION 29, TOWNSHIP 24 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON LYING SOUTHWESTERLY OF EAST MARGINAL WAY SOUTH, AND WESTERLY OF 14TH AVENUE SOUTH, NORTHERLY OF SOUTH WHIPPLE STREET AND EASTERLY OF ABRAM'S ADDITION ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE 30, IN KING COUNTY, WASHINGTON; TOGETHER WITH THAT PORTION OF VACATED SOUTH WHIPPLE STREET AS VACATED BY CITY OF SEATTLE ORDINANCE NUMBER 83417; TOGETHER WITH THOSE PORTIONS OF VACATED SOUTH HOLDEN STREET, SOUTH PORTLAND STREET, 10TH AVENUE SOUTH AND 12TH AVENUE SOUTH AS VACATED BY CITY OF SEATTLE ORDINANCE NUMBER 82999 TOGETHER WITH THOSE PORTIONS OF VACATED SOUTH AUSTIN STREET AS VACATED BY CITY OF SEATTLE ORDINANCE NUMBERS 70513, 82999, 83277 AND 114027; TOGETHER WITH THOSE PORTIONS OF VACATED RIVERSIDE AVENUE SOUTH AS VACATED BY CITY OF SEATTLE ORDINANCE NUMBERS 70513 AND 82999; TOGETHER WITH THAT PORTION OF 14TH AVENUE SOUTH AS VACATED BY CITY OF SEATTLE ORDINANCE NUMBER 81046; TOGETHER WITH THOSE PORTIONS OF SOUTH ELMGROVE STREET, SOUTH MONROE STREET AND 14TH AVENUE SOUTH AS VACATED BY VOLUME 51 OF COMMISSIONER'S RECORDS, PAGE 213. A PRO PERMIT RESUBMITTAL NOVEMBER 04, 2019 FOUNDATIONS FOR VERTICAL STORAGE NITS BUILDING 2-10 SH SITTS & HILL qr. ENGINEERS, INC. ,f,.tic CIVIL • STRUCTURAL • SURVEYING •e '"' E P ENTER STREET I TACOMA, WA. 98409 (253) 474-8448 { FAX: (253) 474&449 www.sittsh8i.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK ENT REVISION 36396 SYMBOL GO DATE 11.04.19 JOB NO. 36396 COMP NO. DWG NO. PLANT 2, WA. 02-10-GO E: 10/09/18 08:58 INDEX OF DRAWINGS INCLUDED IN SET SHEET NO. DRAWING TITLE REV DATE DRAWING NO. GEV-RA_ • 02-10-GO GO COVER SHEET 11.04.19 11.04.19 SHEET INDEX • 02-10-G1 Cl S R,CT„RA_ • 02- 0-1S64R 1S64R PARTIAL FLOOR SLAB PLAN REMOVAL R 11.04.19 11.04.19 • 02-10-1S64 1S64 PARTIAL FLOOR SLAB PLAN • 02-10-S610 S610 GENERAL STRUCTURAL NOTES AND ENLARGED PLAN 11.04.19 • 02-10-S611 S611 FOUNDATION SECTIONS AND DETAILS 11.04.19 SYM REVISION FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 BY SITTS APPROVED DATE SYM REVISION APPROVED DATE BKL 11.04.19 e ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. Kamla DATE SUBTITLE 05.29.19 CHECKED A. Boileau ENGINEER A. Boileau CHECKED APPROVED APPROVED 05.29.19 05.29.19 TITLE nECFAVEn CITY OF 11;liWt1- PE NOV 1 5 2019 MIT ENTER PERMIT RESUBMITTAL NOVEMBER 04, 2019 SHEET INDEX FOUNDATIONS FOR VERTICAL STO 'AGE UNITS BUILDING 2-10 GENERAL PLANT 2, WA. C P F" FZ 0 \I EE -nN 0 ty 0 f Tuk via I BUIDUNG EDPOSION SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX:(25.3)4744449 ,ANNcsiftshilLuxn Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK T REVISION 36396 SYMBOL G1 DATE 11.04.19 JOB NO. 36396 COMP NO. DWG NO. 02-10-G1 20'-0" REVISION ) FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 20'-0" SITTS APPROVED BKL DATE 11.04.19 20'-0" SYM REVISION 20'-0" 20'-0" 20' 0" 20.-0" 8 20.-0" 20'-0" APPROVED DATE gifirAFEAlAW ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 20'-0" REMOVAL DRAWN J. Kamla CHECKED A. Boileau ENGINEER A. Boileau CHECKED APPROVED APPROVED DATE 05.29.19 05.29.19 05.29.19 SUBTITLE TITLE Ci; =C=\D/SC C- ASSHOWN ON PLAN INDICATES EXISTING CONCRETE SLAB TO BE REMOVED. LRAL \0- =S: 1. SEE OTHER DISCIPLINE'S DRAWINGS FOR ADDITIONAL INFORMATION. CO \ S R C 0 \lJ 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. FIELD VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION WHICH AFFECT NEW CONSTRUCTION PRIOR TO SUBMITTAL OF SHOP DRAWINGS. SHOP DRAWINGS WITHOUT FIELD VERIFICATION OF DIMENSIONS SHALL BE REJECTED. SAW CUT AND REMOVE EXISTING CONCRETE SLAB. ER \CI DRAW \C S: SEE DRAWING FOR 2-10-1A14 FOR FLOOR PLAN. SEE DRAWING FOR 02-10-1S64 FOR PARTIAL FLOOR SLAB PLAN. �r T,RECE jV tE1? ` C f,l OF 6UR olLA NOV 15 2O P MIT CENTER 1S60 1S61 1S62 1S63 1565 1S66 1S67 1S68 1S69 1S70 1S71 1S72 1S73 1S74 KEY PLAN SCALE: NONE PERMIT RESUBMITTAL NOVEMBER 04, 2019 PARTIAL FLOOR SLAB PLAN - REMOVAL FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-10 STRUCTURAL MASTER COL. 11-21 /C.5- 0 4 8 16 24 SCALE: 1 /8"=1 '-0" SITTS & HILL ENGINEERS, INC. CML • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 www.sithhIII.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SYMBOL R DATE 11.04.19 COMP NO. 36396 02-10-1S64R 2 2 -G -f\ D/SC ED 20'-0" 20'-0" 20,-0" 20'-0" 20.-0" 20'-0" 20'-0" 20'—O" ,� 20'-0" 20.-0" .11 G-\-RA_ \OT-S: 1. CO\S-R.,C-ON SEE OTHER DISCIPLINE'S DRAWINGS FOR \O--S: ADDITIONAL INFORMATION. MATCHLINE SEE DRAW3ING 1S63 1. 0 FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. 3. R-= FIELD AFFECT SHOP BE SEE REJECTED. 1S64R -R-\C- VERIFY NEW DRAWINGS ALL CONSTRUCTION WITHOUT FOR SLAB DIMENSIONS REMOVAL FIELD DRAWI\GS: OF EXISTING PRIOR TO VERIFICATION PLAN. SUBMITTAL CONSTRUCTION WHICH OF SHOP DRAWING`. OF DIMENSIONS SHALL _ - 0 SEE D DRAWING 2-10-1A14 FOR FLOOR PLAN. MATCHLINE SEE DRAW3ING 1S61 I I 1- _ r— CD w w w Z J 2 U Q M C1 tLl 1S64 S610 `� flfl I 0 , 1560 1S63 1S66 1S69 1S72 1S61 ���� �^ 1S67 1S70 1S73 41) 1S62 1S65 1568 1S71 1S74 KEY CO PLAN N i LIDI SCALE: NONE Ef " 0 4 8 16 24 fEC SCALE: jVE mL:WwillA 1 /8"=1 ' —0" CITY OF NOV P R I 15 2019 CE TE SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING MATCHLINE SEE DRAW3ING 1 S65 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 47441449 PERMIT RESUBMITTAL www.dttshlll.com PAR -A\ AProject _ - _ 0 0 R SLAB L Na.: 16391 Project Mgr.: BKL SCALE: 1/8" = 1'-0" N OV E M B E R 04, 2019 Proj. Engineer: AJB Proj. Drafter: JDK REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 SITTS BKL 11.04.19 Z)L4inerA.E,Aia ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. Kamla CHECKED A. Boileau DATE 05.29.19 05.29.19 SUBTITLE PARTIAL FLOOR SLAB PLAN CURRENT REVISION 36396 SYMBOL DATE 11.04.19 ENGINEER A. Boileau CHECKED APPROVED 05.29.19 TITLE FOUNDATIONS FOR VERTICAL STORAGE UNITS STRUCTURAL MASTER BUILDING 02-10 COL. 11-21 /C.5- PLANT 2, WA SHEET S64 GENERAL STRUCTURAL NOTES CODES AND REFERENCES: 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC), WITH STATE OF WASHINGTON AND CITY OF TUKWILA AMENDMENTS AND SUPPLEMENTED WITH ASCE 7-10. ALL CODE REFERENCES HEREAFTER SHALL CORRESPOND TO THE FOLLOWING EDITIONS, U.N.O.: MATERIAL CONCRETE STRUCTURAL STEEL STRUCTURAL STEEL WELDING CODE EDIi1ON BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, ACI 318-14. 14TH EDITION OF STEEL CONSTRUCTION MANUAL (RISC SCM) INCLUDING THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AISC 360-10. STRUCTURAL WELDING CODE — STEEL, AWS D1.1-15. LOADS: RISK CATEGORY = II. DEAD LOADS: ACTUAL WEIGHT OF INSTALLED AND LOADED VERTICAL STORAGE UNITS (VSO's). SEISMIC: IIMPORTANCE FACTOR le = 1.0. LATITUDE = 47.5318; LONGITUDE _—122.3151 Ss = 1.516, S1 = 0.579, SEISMIC SITE CLASS = D (ASSUMED). Sds = 1.011, Sd1 = 0.579, SEISMIC DESIGN CATEGORY = D. SEISMIC —FORCE —RESISTING SYSTEM: ALL OTHER SELF—SUPPORTING STRUCTURES, TANKS, OR VESSELS REFERENCE STANDARDS THAT ARE NOT SIMILAR TO BUILDINGS. SEISMIC RESPONSE COEFFICIENT, Cs = 0.8088. RESPONSE MODIFICATION FACTOR, R = 1.25. ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE. DESIGN WEIGHT OF EMPTY VSU = 15,561 LBS. DESIGN MAX VSU STORAGE WEIGHT = 70,217 LBS. DESIGN VSU EFFECTIVE SEISMIC WEIGHT = 15,561 LBS + (0.67)x70,217 LBS = 62,606 LBS. DESIGN VSU DESIGN BASE SHEAR = 50,636 LBS. DESIGN VSU SIZE = 9.12' x 10.08' x 26.41' HIGH. FOUNDATIONS: NOT COVERED ABOVE OR BY FOUNDATION SHALL BEAR ON FIRM, UNDISTURBED SOIL OR CONTROLLED COMPACTED FILL. ASSUMED DESIGN SOIL BEARING VALUE = 1,500 PSF. CONCRETE: MINIMUM 28—DAY STRENGTH OF CONCRETE SHALL 4,000 PSI. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED. REINFORCING STEEL FOR CONCRETE: USE ASTM A615, GRADE 60 (FY = 60 KSI), DEFORMED BARS FOR ALL BARS. ALL GRADE 60 REINFORCING BARS TO BE WELDED SHALL BE ASTM A706. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. ACI 318 SHALL APPLY. SUPPORT OF FOUNDATION REINFORCING MUST PROVIDE ISOLATION FROM MOISTURE AND CORROSION. REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS SHALL BE PER ACI SP-66. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION WITH STANDARD 90—DEGREE HOOKS, U.N.O. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. LAP SPUCES IN CONCRETE: LAP SPLICES, U.N.O., SHALL BE CLASS "B" TENSION LAP SPLICES PER ACI 318. STAGGER SPLICES A MINIMUM OF (1) LAP LENGTH. ALL SPLICE LOCATIONS SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. REINFORCING STEEL COVER: ALL REINFORCING SHALL BE CHAIRED TO ENSURE PROPER CLEARANCES. CLEAR CONCRETE COVERAGES AS FOLLOWS: CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH• EXPOSED TO EARTH OR WEATHER #6 OR LARGER #5 AND SMALLER ALL OTHER PER ACI 318 • 3" 2" • 1 1/2" ADHESIVE DOWELS: ALL ADHESIVE DOWELS SHALL UTILIZE HILTI HIT—HY 200 EPDXY (ICC ESR-3187) OR APPROVED EQUIVALENT. STRUCTURAL STEEL: ALL CONSTRUCTION SHALL BE PER AISC—SCM. ALL PIPE STEEL SHALL BE ASTM A53, TYPE E OR S, GRADE B (FY = 35KS1). ALL OTHER STRUCTURAL STEEL SHALL BE ASTM A36 (FY = 36 KSI), U.N.O. BOLTS: ALL BOLTS SHALL CONFORM TO ASTM A307, GRADE A, U.N.O. EXPANSION BOLTS IN CONCRETE: ALL EXPANSION BOLTS SHALL HAVE CURRENT ICC APPROVAL FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE, SUCH AS HILTI KWIK BOLT TZ (ICC ESR-1917) OR APPROVED EQUIVALENT. WELDING: WELDERS HOLDING VALID W.A.B.O. OR AWS CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES SHALL PERFORM ALL WELDING. CERTIFICATES SHALL BE THOSE ISSUED BY AN ACCEPTED TESTING AGENCY. ALL WELDING DONE BY E70 SERIES LOW HYDROGEN RODS, U.N.O. FOR GRADE 60 REINFORCING BARS, USE E90 SERIES. ALL WELDING SHALL BE PER LATEST AWS STANDARD. THESE DRAWINGS DO NOT DISTINGUISH BETWEEN SHOP AND FIELD WELDS; THE CONTRACTOR MAY SHOP WELD OR FIELD WELD AT THEIR DISCRETION. SHOP WELDS AND FIELD WELDS SHALL BE SHOWN ON THE SHOP DRAWINGS SUBMITTED FOR REVIEW. ALL FULL/COMPLETE PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. G _-_RA L S SCALE: N.T.S. R„GT�RAL \OT REVISION IS BY APPROVED DATE SYM SHOP DRAWINGS: SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS SHALL BE FLAGGED UPON CONTRACTOR'S REVIEW. VERIFY ALL DIMENSIONS WITH EXISTING CONSTRUCTION AND COORDINATE WITH ENGINEER. MANUFACTURER OR FABRICATOR SHALL CLOUD ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DOCUMENTS. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW, U.N.Q. THE ENGINEER HAS THE RIGHT TO APPROVE OR DISAPPROVE ANY CHANGES TO CONTRACT DOCUMENTS AT ANY TIME BEFORE OR AFTER SHOP DRAWING REVIEW. THE SHOP DRAWINGS DO NOT REPLACE THE CONTRACT DOCUMENTS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER SHALL NOT BE CONSIDERED CHANGES TO CONTRACT DOCUMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ITEMS ARE CONSTRUCTED TO CONTRACT DOCUMENTS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. CONTRACTOR HAS THE RESPONSIBILITY OF THE CORRECTNESS OF ALL APPROVAL DRAWINGS. GENERAL: THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT ARE NOT LIMITED TO BRACING AND SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS OR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDA, U.N.O. ESTABIJSH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH EXISTING CONSTRUCTION PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ENGINEER. TYPICAL DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY, U.N.O. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND/OR SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A REGISTERED ENGINEER RECOGNIZED BY THE BUILDING CODE JURISDICTION OF THIS PROJECT. SPECIAL STRUCTURAL INSPECTION: SPECIAL INSPECTION IS TO BE PROVIDED FOR THE ITEMS LISTED BELOW IN ADDITION TO THE INSPECTIONS CONDUCTED BY THE BUILDING SAFETY DEPARTMENT. "SPECIAL STRUCTURAL INSPECTION" SHALL NOT RELIEVE THE OWNER OR THEIR AGENT FROM REQUESTING THE CITY INSPECTIONS REQUIRED BY IBC SECTION 110.3. SPECIAL INSPECTION IS REQUIRED PER SECTIONS 1704 AND 1705 FOR THE FOLLOWING: CONCRETE: A) DURING THE TAKING OF TEST SPECIMENS. B) DURING THE PLACEMENT OF ALL REINFORCED CONCRETE, U.N.Q. C) VERIFICATION OF CURING TEMPERATURE AND TECHNIQUE (PERIODIC). 2. BOLTS IN CONCRLIL: A) DURING THE PLACING OF CONCRETE AROUND BOLTS. 3. REINFORCING STEEL (PERIODIC): A) DURING THE PLACING OF REINFORCING STEEL FOR ALL CONCRETE REQUIRED TO HAVE SPECIAL INSPECTION NOTED ABOVE. 4. WELDING: A) VISUAL INSPECTION OF ALL FIELD WELDS. B) NON—DESTRUCTIVE TESTING OF ALL COMPLETE PENETRATION WELDS. 5. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR: A) THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B) PER IBC SECTION 1704.2.4: THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND TO THE ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. SUBMIT A FINAL REPORT AS REQUIRED. C) UPON COMPLETION OF THE ASSIGNED WORK, THE ENGINEER SHALL COMPLETE AND SIGN THE APPROPRIATE FORMS CERTIFYING THAT, TO THE BEST OF THEIR KNOWLEDGE, THE WORK IS IN CONFORMANCE WITH THE APPROVED PLANS, SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. FOR ADDITIONAL INFORMATION ON SPECIAL STRUCTURAL INSPECTIONS, CONTACT STRUCTURAL ENGINEER PRIOR TO START OF CONSTRUCTION. REVISION BY APPROVED DATE FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 SITTS BKL 11.04.19 ("H S610 4'- 20'-0' 10'-1" (TYP.) 2'-3" THICK VSU r_ FOUNDATION VSU (3 LOCATIONS) 2'-9" 4'-7 1/8" IN ON EMBED 2,-6" 0 W m u� CV TYP. A S610 S611 VSU COLUMNS AND BASE ASSEMBLIES (24 LOCATIONS) EMBED EMBED EMBED 2'-4 7/8" 2'-4 7/8" 17'-6" 20'-0" 5'-11" TYP. AT EXTERIOR 4 VSU COLUMNS S610 S6 4'-7 1/8" 2'-9" 2'-4 7/8" EMBED TYP. AT INTERIOR VSU COLUMNS S610 S611 �.1 16'-6" EMBED EMBED 2'-4 7/8" 3'-6" \_ARG-D VS.J SCALE: 1/4" = elAirAFEAVAW ® ti DATIO\ ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 3LA\ DRAWN J. Kamla CHECKED A. Boileau ENGINEER A. Boileau CHECKED DATE 05.29.19 05.29.19 05.29.19 SUBTITLE TITLE STRUCTURAL flECEIVEn CITY OF TUI(V A NOV 15 2019 P MIT E T PERMIT RESUBMITTAL NOVEMBER 04, 2019 GENERAL STRUCTURAL NOTES AND ENLARGED PLAN FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-10 GENERAL NOTES: 1. SEE DETAIL 1/S610 FOR GENERAL STRUCTURAL NOTES. 2. SEE DETAILS 1/S611, 2/S611, AND 3/S611 FOR TYPICAL REINFORCING DETAILS. BOLLARD PER DETAIL 6/S611. 0 CONSTRUCTION NOTES: ► VERIFY VERTICAL STORAGE UNIT (VSU) DIMENSIONS, REQUIRED SPACE BETWEEN ADJACENT CONNECTED VSU'S, AND VSU TO VSU CONNECTION WITH THE EQUIPMENT MANUFACTURER'S REPRESENTATIVE. OBTAIN THE FOLLOWING FROM THE EQUIPMENT MANUFACTURER'S REPRESENTATIVE: A. B. C. D. BASE ASSEMBLY LAYOUT DIMENSIONS. ALLOWABLE BASE ASSEMBLY PLACEMENT TOLERANCES. THICKNESS OF BASE ASSEMBLIES. BASE ASSEMBLY CONNECTION OPTION TO BE USED. PROVIDE E.O.R. RED —LINED PLANS SHOWING THE AS —BUILT BASE ASSEMBLY LAYOUT DIMENSIONS, THICKNESSES, AND CONNECTION OPTIONS USED. 2 4 (2 1S64 S610 8 12 SCALE: 1 /4"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-0449 www.slttshlll.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SYMBOL DATE 11.04.19 SHEET 610 COMP NO. X:\FRDRCKSN\24-60C\STRUCT\S522- U a) NOTES: A. VSU FOUNDATION INFORMATION NOT SHOWN FOR CLARITY, NOTES: S610 S611 CO\CR I\ SCALE: N.T.S. CLASS "B" LAP SPLICE LENGTH (IN INCHES) F'c=4,000 PSI REG TOP 3 20 26 #4 26 34 #5 32 42 #6 38 50 RCI\ G _AP S3LIC= SC ID 1 1/2" TYP. \\‘``""-` \"\ S. S. 5, N N =R SCALE: 3" OR VS" , SYM #4x24" DOWELS AT 24" O.C. AT MID —DEPTH OF EXISTING SLAB, EMBED 4" IN ADHESIVE PER G.S.N. EXISTING SLAB vs SCALE: 1" = \DA ,-0„ 0\ S (2) #4 x 4'-0" TOP AND BOTTO R =ORCI =C 0\ \CATS PLAN _AB COR\ VSU FOUNDATION #6AT8"O.C. #6 AT 8" O.C. RE—ENTRANT SLAB CORNER SERVICE ACCESS PIT OR ADJACENT EXISTING SLAB =R D COMPACT SUBGRADE TO 95% DRY DENSITY (A� S610 S611 SCALE: N.T.S. REVISION FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 BY SITTS APPROVED BKL S610 S611 SYM 5/16 EMBED PLATE PER PLAN AND DETAILS r.__ TOP OF VSU FOUNDATION B=D =v DLAT�. SCALE: 1 1/2" = 1 -0" =X R =1\ 1'-0" V _\T S 1 1/2" TYP. Om- #5 ASTM A706 REBAR BOTTOM OF VSU FOUNDATION =CTI O \ r_ 1" THICK EMBED PLATE 10 \\.»1ti\.\\\\\\.\.\\-\\.»»\\ \,\N. \ IRIOR VS, COL V #5 ASTM A706 REBAR, TYP. A vB VSU COLUMN AND BASE ADAPTER PER MANUFACTURER 5/16 S611 TYP. 3 SIDES AS INDICATED PLATE 1"x5"x0'-9" VSU COLUMN BASE PLATE PER MANUFACTURER CENTERED ON EMBED PLATE S611 =D PLA SCALE: 3" = 1'-0" REVISION BY APPROVED DATE DATE 11.04.19 CO M AT A. TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. B. UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS, WALLS, AND FOOTINGS SHALL BE CLASS "B" TENSION LAP SPLICES. C. CONTACT STRUCTURAL ENGINEER IF CENTER —TO —CENTER SPACING OF REINFORCEMENT IS LESS THAN (3) BAR DIAMETERS (<3DB). D. LAP SPLICES BASED UPON 60 KSI STEEL. 1" THICK EMBED PLATE #5 ASTM A706 REBAR, TYP. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE V B S6101S611 VSU COLUMN AND BASE ADAPTER PER MANUFACTURER TYP. 3 SIDES 5/16 / AS INDICATED PLATE 1"x5"x0'-9" VSU COLUMN BASE PLATE PER MANUFACTURER CENTERED ON EMBED PLATE 1/4:43 S611 ID PLA DRAWN J. Kamla CHECKED A. Boileau ENGINEER A. Boileau CHECKED APPROVED APPROVED (5� S610 S611 DATE 05.29.19 05.29.19 05.29.19 SUBTITLE TITLE STRUCTURAL CO\ CR SCALE: N.T.S. S 1db (1" MINIMUM) 6 MIN 1 BAR CLEARANCE BAR OFFSET BEND AND HOOK DETAILS =R BOL LAP PER TYPICAL SCHEDULE WIRE TIE SPLICE DETAIL 4db (2 1/2" MINIMUM) INSIDE BEND RADIUS: #3 TO #8 BARS = 3db \FORC \G BAR D _AR D D A L =TA 1/4" TYPICAL STEEL CAP PLATE MAXIMUM 1/5 LAP BUT NOT MORE THAN 6" (Th S610 S611 6" DIA. SCH. 40 PIPE — APPLY PRIMER (1 COAT) AND PAINT SAFETY YELLOW (2 COATS) ALKYD ENAMEL PLATE 3/4"x10" SQ. WITH (4) 3/4" EXPANSION BOLTS PER G.S.N. EMBED 4 3/4" MIN. CONCRETE SLAB AS OCCURS SCALE: N.T.S. RECEiVEf CITY OF "t`U R'N A NOV 15 2019 PE CE TER PERMIT RESUBMITTAL NOVEMBER 04, 2019 FOUNDATION SECTIONS AND DETAILS FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-10 0 3" 6" S610 S611 9" 1 SCALE: 3"= 1 '-0" 0 6" 1 2 SCALE: 1 1 /2"=1'—O" SITTS & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474.9449 I FAX: (253) 474-9449 www.slttshlll.cnan Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SYMBOL DATE 11.04.19 SHEET WG NO S611 36396 COMP NO. 02-10—S611 X:\FRDRCKSN\24-60C\STRUCT\S522-8A BOEING COMMERCIAL AIRPLANES PLANT 2 2m10 FOUNDATIONS FOR VERTICAL STORAGE UNITS LOCATION ' | / DES [ ! NN TO T A EVERL|| OND ISSAQUAH PROJECT SITE RENTUN| KENT AUBURN o8URNI REVISION BY DOD APPROVED SYM VICINITY MAP 141, SCALE: NONE ° ^._2_14 V- � aw ���7��� �_ U SITE PROJECT K—����,����� REVISION BY APPROVED FOUNDATIONS FOR VERTICAL STORAGE UNITS BKL CODE SUMMARY BUILDING CODE: IBC 2015 EDITION AS ADOPTED BY THE CITY OF TUKWILA SEISMIC ZONE: USE GROUP 1, IMPORTANCE FACTOR l. SEISMIC DESIGN CATEGORY D SITE CLASS D. OCCUPANCY GROUP: CONSTRUCTION TYPE: TOTAL BUILDING AREA: CONSTRUCTION AREA: BUILDING HEIGHT: F1 — FACTORY Sl — STORAGE, AIRCRAFT TIRES S2 STORAGE, AIRCRAFT TOOLS U| — B 406.979 5Q FT 649 3O FT 46 FT. ONE PROJECT SUMMARY DESCRIPTION OF WORK: INSTALL FOUNDATIONS AND ANCHORS TO SUPPORT NEW VERTICAL STORAGE UNITS. PROJECT COST: CONTRACTOR: SITE ADDRESS: OWNER CONTACT: 1155 SOUTH WEB5TER STREET SEATTLE, W& BOE|NG COMMERCIAL AIRPLANES P.O. BOX 3707, W/S: 1YY-10 3E/ATLE, WA. 98124-2207 KING COUNTY PARCEL NO. 0022000005 SEATTLE � ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE DRAWN J.Kumla CHECKED A. Boileau ENGINEER A. Boileau DATE 05.29.19 05.29.19 05.29.19 APPROVED APPROVED SUBTITLE � � � �_"° m� ~���~� . � o^��������� � i� 2 8 REVIEVVT,---'D FOR CODECOMPLiANCE/ A�*PROVED o~ ,r City of Tukwila UKZQNC; OIV�S>ON LEGAL DESCRIPTION APN: 002200-0005 ALL BLOCKS 1, 3, 4, 5 AND 6. *BRAM'3 ADDITION TO SOUTH 5E4TTL . ACCORDING TO THE PLAT 7UEREOFRECORDED IN VOLUME 11 OF PUT5, PAGE 30. IN K|wo oouNTT. W«S*|NGTDw. EXCEPT THAT rUnnow OF BLOCK 3 DESCRIBED AS FOLLOWS: COMMENCING AT THE CENTERLINE INTERSECTION OF 12TH AVENUE SOUTH AND SOUTH AU3TIN STREET. THENCE SOUTH 88"20'05^EAST A0wC THE CENTERLINE OF SOUTH AUSTIN STREET 8e.88 FEET. THENCE SOUTH 01*33'55^WEST 12.00 FEET To THE 300x MARGIN OF SOUTH AuSTIN STREET AND THE TRUE POINT OF 8D:|Nm|mo: THENCE SOUTH 02*17'42^wE3T 23.09 FEET; THENCE SOUTH 42'20'44^ wE3r 4524 FEET; THENCE NORTH 48'22'0*^wEST 89.35 FEET TO THE SOUTH MARGIN OF SOUTH AU5nN STREET; THENCE 5O0o 88'20'05^EAS 9823 FEET ALONG SAID MARGIN TO THE TRUE POINT OF BEGINNING AND EXCEPT u]T3 1. 7 AND o. o|ocx §; AND EXCEPT THAT PORTION OF 0T 5. BLOCK b; CONDEMNED IN x|wC COUNTY SUPERIOR COURT CASE NUMBER 102874 FOR EAST MARGINAL WAY; ALL OF BLOCKS Jz, JJ. 34. 41. *2. *3 AND 4*. RIVER n^nx ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 7 OF PuT5, PAGE 41. IN KING COUNTY, «wSmwCTOw; EXCEPT THOSE PORTIONS OF BLOCKS 32. oJ. 34 AND *l LYING w|T*|N COMMERCIAL WATERWAY NO. 1 (ALSO KNOWN AS Duvmu|3H WATERWAY) EXCEPT L03 7 AND 0' BLOCK ^J; TooETx[n WITH THAT PORTION Or SECTION zy. TOwwsmp z* w0RTo. RANGE ^ EAST, *uLawIE//E wEe|Omw. IN x|wG COUNTY, WASH|NnTOw LYING NORTHEASTERLY OF THE RIGHT OF WAY OF COMMERCIAL WATERWAY NO. 1. AND LYING SOUTHEASTERLY Or THE MEDIAN LINE OF nB|3[D SLIP NO.* AS DESCRIBED IN INSTRUMENT RECORDED UNDER RECORDING NUMBER 4477037 AND u(|wG SOUTHWESTERLY OF A LNE 68s/NNIwC AT 7,`iE »0En5[S�itli OF THE SOUTH LINE OF LOT 7. BLOCK 43, RIVER PARK, PROJECTED WESTERLY WITH THE SOUTHEASTERLY MARGIN OF SAID SLIP NO. 4 AS ESTABLISHED BY COMMERCIALWATERWAYWATERWAY� WATERWAY NO. l AND AS SHOWN ON THE MAP OF THE DISTRICT PREPARED BY ITS CHIEF ENGINEER IN 1916, THENCE NORTHWESTERLY, PERPENDICULAR TO THE NORTHWESTERLY MARGIN OF VACATED RIVERSIDE xvENu[ AS PLATTED IN SAID RIVER PARK TO AN |NTEe3D:T|OW WITH SAID MEDIAN LINE; ALL OF BLOCKS 1, 2, J. 4 AND 5, EAST SOUTH PARK. ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 1* OF PUT5, PACE 13. IN K|mS COUNTY, vm3H|NGTON; EXCEPT THOSE PORTIONS OF BLOCKS 2, J. 1 AND 5 LYING WITHIN COMMERCIAL WATER WAY NO. l (ALSO KNOWN AS DUWAM|5H WATERWAY) EXCEPT THOSE PORTIONS OF BLOCKS | AND 4 CONVEYED TO KING COUNTY BY DEEDS RECORDED UNDER RECORDING NUMBERS 25*7379. 2556875, 2556877 AND 2557326; EXCEPT THOSE PORTIONS OF BLOCKS 4 AND 5 LYING EASTERLY OF 16TH AVENUE SOUTH AS CONVEYED TO KING COUNTY BY DEED RECORDED UNDER RECORDING NUMBERS 2547379, 2556875. 2555877. 2557326 AND 2559383; TOGETHER WITH THAT PORTION OF GOVERNMENT LOT 1, SECTION 32. TOWNSHIP 24 NORTH, RANGE 4 EAST, W|LLAwL|/[ u[n|o|*w. IN KING Cnuwn, WAomwJ0w, DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHWEST CORNER OF LOT 17, BLOCK 2, SAID PLAT OF EAST SOUTH PARK; THENCE NORTH 09'4'26^WEST ALONG THE LINE BETWEEN SECTIONS 28 AND 32 IN SAID TOWNSHIP AND RANGE A DISTANCE OF 70J43 FEB TO A POINT BEING THE INTERSECTION OF SAID SECTION LINE WITH THE NORTHEASTERLY RIGHT OF WAY LINE OF COMMERCIAL WATERWAY NO 1; THENCE SOUTH 49'00'80^EA3 ALONG THE SAID NORTHEASTERLY mOxT OF wwX LINE A DISTANCE OF 92.9*5 FEET MORE on Lcss TO AN |wTcnscoTmm WITH THE WEST LINE OF SAID LOT 17; THENCE NORTH 0'33'43^ cxsT ALONG SAID WEST LINE A DISTANCE OF 59.837 FEB MORE OR LESS TO THE POINT OF BEGINNING. x PARCEL OF Lxwo IN GOVERNMENT 0T 13. SECTION 29. TOWNSHIP 2* N0nT*. RANGE 4 B\3T. W|LU\ME//E u[a0|Aw. IN KING COUNTY, wASH|NGT0N . AND IN THE PUT OF EAST SOUTH PARK, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 14 OF PUTS, PAGE 13. IN KING COUNTY, WA3H|NGTON. DESCRIBED AS FOLLOWS: BEGINNING ON THE NORTH LINE OF SAID SECTION 32 AT ITS INTERSECTION WITH THE WEST LINE OF 16TH AVENUE SOUTH AND BEING 04.80 FEB. MORE OR LESS w[3T OF THE NORTHEAST CORNER OF THEREOF; THENCE NORTHERLY ALONG THE WEST MARGIN OF 15TH AVENUE SOUTH TO 4 LINE WHICH IS PARALLEL TO AND 419 FEB NORTHERLY OF THE SOUTH LINE OF SAID GOVERNMENT LOT 13; THENCE NORTH 89'16'44^WEST ALONG SAID LINE 100 FEET; THENCE NORTH 0'49'03^B\3T ALONG x LINE PARALLEL TO THE WESTERLY wxRC|N OF 10Tx AVENUE 3UuT* 123.11 FEET; THENCE NORTH +S'On'JV^ WEST 128 FEET; THENCE NORTH Os' 16'4*^WEST 95 FEET; THENCE NORTH +9*00'30^WESr 25 rEB. MORE OR LESS TO THE EAST MARGIN OF 1*T* w/Ewu[ SOUTH THENCE WEST ALONG THE wOmx LINE Or THAT PORTION OF 14Tx AVENUE 5OVr* VACATED BY CITY OF 5EAnL[ ORDINANCE NUMBER 81045 BEING 637.11 FEET NORTH FROM THE SOUTH LINE OF SAID GOVERNMENT LOT 13 TO THE WESTERLY MARGIN OF 1*TH AVENUE SOUTH; THENCE NORTHERLY ALONG SAID WESTERLY MARGIN AND SAID MARGIN EXTENDED TO THE CENTERLINE OF VACATED WH|PPLE STREET; THENCE SOUTHWESTERLY ALONG SAID CENTERLINE TO THE WEST LINE OF SAID GOVERNMENT LOT 13; THENCE SOUTHERLY ALONG SAID WEST LINE TO THE NORTHEASTERLY LINE OF THE DuxAm|So WATcnwmx Txcwcc soor* +e'OV'nn^ EAST mmwn SAID wom*msrsnc/ LINE *yo.l+ pssT To THE soul* uws OF SAID GOVERNMENT 0T; THENCE EAST ALONG THE SOUTH uw[ TO THE POINT OF 8EC|ww|wn; EXCEPT THAT PORTION DESCRIBED AS FOLLOWS: 8[S|NN|m8 AT A POINT AT THE INTERSECTION OF THE NORTH LINE OF THE SOUTH 419 FEET OF SAID GOVERNMENT LOT 13 WITH THE WESTERLY MARGIN OF 16TH AVENUE SOUTH; THENCE NORTH 8e'16'44^w[ST 100 FEET; THENCE SOUTHEASTERLY ALONG A CURVE TO THE LEFT THE RADIUS OF WHICH BEARS NORTH 65'27'21^EA3 100 FEET TO THE WESTERLY MARGIN OF SAID 16TH AVENUE SOUTH; THENCE NORTHERLY 55 FEB TO THE BEGINNING; THAT PORTION OF THE EASTERLY 59* FEET OF GOVERNMENT Uo 13, SECTION 28, TOww3*|p 24 NORTH. RANGE * [AST. w|LLxML/|E MER0|mu. IN x|mG COUNTY. WA5H/wGTnN LYING SOUTHWESTERLY OF EAST MARGINAL WAY SOUTH. AND WESTERLY OF 14T* AVENUE SOUTH' NORTHERLY OF SOUTH WmPPLE STREET AND EASTERLY OF A8nAM'S ADDITION ACCORDING TO THE PUT THEREOF RECORDED IN vVLuWE 11 OF PuATS, PAGE JO. IN KING COUNTY. wA3x|wGTDN; TOGETHER WITH THAT PORTION OF VACATED SOUTH WH|pPL[ STREET AS VACATED BY CITY OF SEATTLE ORDINANCE NUMBER 83417; TOGETHER WITH THOSE pURT0w3 OF VACATED SOUTH HOLDEN 3TREET, SOUTH P8RTwwD STREET, 10T* w/EwuE SOUTH AND 12TH AVENUE SOUTH AS VACATED BY CITY OF 3cmTLE ORDINANCE NUMBER 82999 TOGETHER WITH THOSE PORTIONS OF VACATED SOUTH mJST|w STREET AS VACATED BY CITY OF 3EATT|E ORDINANCE NUMBERS 70513. 0988, 83277 AND 11*827; TOGETHER WITH THOSE PORTIONS OF VACATED R|V[R50[ AVENUE SOUTH AS VACATED BY CITY OF 8EATTLE ORDINANCE NUMBERS 70513 AND 82989; TOGETHER WITH THAT PORTION OF 14TH AVENUE SOUTH AS VACATED BY CITY OF 3cATTL[ ORDINANCE NUMBER 810*6; TOGETHER WITH THOSE PORTIONS OF SOUTH ELMGRUYE 3TREB, SOUTH MONR0E STREET AND 1*T* AVENUE SOUTH AS VACATED BY VOLUME 51 OF COMMISSIONER'S R[%OR85, PAGE 273. ILI N0�� — � � N AUG 1 5 2019 ISSUED ����� ������N�U�F h�������-�� K—��F� PERMIT AUGUST �� ��4� ��, u��|� COVER �//��.�A��T FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 2 10 PLANT 2, WA. �� �� HILL ~~ou u=� �� ���d�8������� INC.~"�~wm,�u~~~x�°�, "°��+ xmu ^ ar*uorunxL ^ ounvsnwo 48oCENTER STREET / `mv:A,WA. o84^ PHONE: (253) 4744449 / FAX: (253)"a+w9 Project No.: 18391 Project Mgr.: BKL CURRENT REVISION JOJSO 08.09.19 DATE SHEET GO 36396 DWG NO. O2-10—GO 10/09 /18 08:58 INDEX OF DRAWINGS INCLUDED IN SET DRAWING NO. SHEET NO. DRAWING TITLE REV DATE GI\ IRA • 02-10-GO • 02-10-G1 GO G1 COVER SHEET SHEET INDEX 08.09.19 08.09.19 STR C URA_ • 02-10-1S64R 1S64R • 02-10-1S64 1S64 • 02-10-S610 S610 • 02-10-S611 S611 PARTIAL FLOOR SLAB PLAN - REMOVAL PARTIAL FLOOR SLAB PLAN GENERAL STRUCTURAL NOTES AND ENLARGED PLAN FOUNDATION SECTIONS AND DETAILS R 08.09.19 08.09.19 08.09.19 08.09.19 V =C A\ CA O 02-010-1M264 1M264 FIRE PROTECTION A 08.09.19 RICA Q 02-010-E1 El Q 02-010-1E114 1E114 Q 02-010-1E364 1E364 ELECTRICAL LEGEND & ABBREVIATIONS 480Y/277 VOLT POWER PARTIAL 1ST FLOOR COMMUNICATIONS PLAN B 08.09.19 B 08.09.19 A 08.09.19 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 SITTS BKL 08.09.19 ZI___AsusrAcrAw ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. Kamla CAD A. Boileau ENCTREER A. Boileau CHECKED APPROVED APPROVED DATE 05.29.19 05.29.19 05.29.19 SUBTITLE TITLE AUG 1 4 2019 ISSUED FOR PERMIT AUGUST 09, 2019 SHEET INDEX FOUNDATIONS FOR VERTICAL STORM UN BUILDING 2-10 GENERAL PLANT 2, WA. REVIEWED FOR DE COMPLIANCE APPROVED 2019 City ofTukwiIa BUILDINt, DIVISION SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE (253) 474-9449 I FAX: (253) 474-9449 www.sittshill.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK SYMBOL G1 DATE 08.09.19 JOB NO. 36396 COMP NO. DWG NO. 02-10-G1 20'-0" 20'—O" %.. -- 20'— 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" REVISION FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 BY SITTS APPROVED BKL DATE 08.09,19 SYM REVISION 1 BY APPROVED DATE ce;LArzaw,Aw ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE 0 rD REMOVAL DRAWN J. Kamla CHECKED A. Boileau ENGINEER A. Boileau CHECKED APPROVED APPROVED DATE 05.29.19 05.29,19 05.29.19 SUBTITLE TITLE 0 IC C \D/SC -D AS SHOWN ON PLAN INDICATES EXISTING CONCRETE SLAB TO BE REMOVED. ERA \0 ES: 1. SEE OTHER DISCIPLINE'S DRAWINGS FOR ADDITIONAL INFORMATION. CO S RC 10\ \0 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. FIELD VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION WHICH AFFECT NEW CONSTRUCTION PRIOR TO SUBMITTAL OF SHOP DRAWINGS. SHOP DRAWINGS WITHOUT FIELD VERIFICATION OF DIMENSIONS SHALL BE REJECTED. SAW CUT AND REMOVE EXISTING CONCRETE SLAB. =R C DRAW GS: SEE DRAWING FOR 2-10-1A14 FOR FLOOR PLAN. SEE DRAWING FOR 02-10-1S64 FOR PARTIAL FLOOR SLAB PLAN. RB.VIE D F6R CODE COMPLIANCE APPROVED AUG ? ` 2L,1' Cr1,y of Tukwila BUILDING DIVISION ,; 1 5 2019 r 1S60 1563 1566 1S69 1S72 1S61 j1S64,4 1S67 1S70 1S73 1S62 1565 1S68 1S71 1574 KEY PLAN SCALE: NONE ISSUED FOR PERMIT AUGUST 09, 2019 PARTIAL FLOOR SLAB PLAN - REMOVAL FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-10 STRUCTURAL MASTER COL. 11-21/C.5-E. 0 4 16 24 MI II 11111111111111111111 M111111111111111111111111111111111111 MI INS SCALE: 1 /8"=1 ' —0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 www,sittshill.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SYMBOL DATE 08.09.19 SHEET OB± 0 PLANT 2, WA DWG ' . 64R 6396 02-10-1S64R COMP NO, SYM 20'-0" 20'-0 1S64 S610 REVISION FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 BY SITTS APPROVED BKL DATE 08.09.19 20'-0" 20'-0" SYM REVISION 20'-0" MATCHLINE SEE DRAW3ING 1S63 20'-0" 20'-0" 2 If MATCHLINE SEE DRAW3ING 1S65 BY APPROVED DATE �BOE/NG® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 20'-0" DRAWN J. Kamla CHECKED A. Boileau IN MEEhi A. Boileau CHECKED APPROVED APPROVED 20'-0" MATCHLINE SEE DRAW3ING 1S67 DATE SUBTITLE 05.29.19 TITLE 0 M =G \D SC =D.�L GE\ =RAL \O ES: SEE OTHER DISCIPLINE'S DRAWINGS FOR ADDITIONAL INFORMATION. CO\S R,C 0\ \OT =S: FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. FIELD VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION WHICH AFFECT NEW CONSTRUCTION PRIOR TO SUBMITTAL OF SHOP DRAWINGS. SHOP DRAWINGS WITHOUT FIELD VERIFICATION OF DIMENSIONS SHALL BE REJECTED. SEE 1S64R FOR SLAB REMOVAL PLAN. =R=\C DRAW GS: SEE DRAWING 2-10-1A14 FOR FLOOR PLAN. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 27 2019 ty of Tukwila BUILDING DIV!SI N AUG 1 2 '''; x 3 t. T CENTER 21 31 41 47 I I I 1S60 1S61 1S62 1S63 1S65 1S66 1S67 1S68 1S69 1S70 1S71 1S72 1S73 1S74 KEY PLAN ¢t..al r: NONE ISSUED FOR PERMIT AUGUST 09, 2019 PARTIAL FLOOR SLAB PLAN FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-10 STRUCTURAL MASTER COL. 1 1-21 /C.5 0 4 8 16 24 SCALE: 1 /8"=1 '-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET PHONE: (253) 474-9449 I TACOMA, WA. 98409 I FAX: (253) 474-9449 www.sittshill.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SHEET SYMBOL DATE 1S64 08.09.19 COMP NO. 36396 02-10-1S64 CV 0 a GENERAL STRUCTURAL NOTES CODES AND REFERENCES: GENERAL: GEN ERAL NOTES: 1. SEE DETAIL 1/S610 FOR GENERAL STRUCTURAL NOTES. S610 4'-11" 20'-0" 10'-1" (TYP.) VSU (3 LOCATIONS) TYP. A S610 S611 20'-0" 2'-3" THICK VSU FOUNDATION c CV J 0 _ARG=D VS SCALE: 1/4" = 1-0" SYM 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC), WITH STATE OF WASHINGTON AND CITY OF TUKWILA AMENDMENTS AND SUPPLEMENTED WITH ASCE 7-10. ALL CODE REFERENCES HEREAFTER SHALL CORRESPOND TO THE FOLLOWING EDITIONS, U.N.O.: MATERIAL CONCRETE STRUCTURAL STEEL CODE EDITION BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, ACI 318-14. 14TH EDITION OF STEEL CONSTRUCTION MANUAL (AISC SCM) INCLUDING THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AISC 360-10. LOADS: RISK CATEGORY = II. DEAD LOADS: ACTUAL WEIGHT OF INSTALLED AND LOADED VERTICAL STORAGE UNITS (VSU's). SEISMIC: (IMPORTANCE FACTOR le = 1.0. LATITUDE = 47.5318; LONGITUDE =—122.3151 Ss = 1.516, S1 = 0.579, SEISMIC SITE CLASS = D (ASSUMED). Sds = 1.011, Sd1 = 0.579, SEISMIC DESIGN CATEGORY = D. SEISMIC —FORCE —RESISTING SYSTEM: ALL OTHER SELF—SUPPORTING STRUCTURES, TANKS, OR VESSELS NOT COVERED ABOVE OR BY REFERENCE STANDARDS THAT ARE NOT SIMILAR TO BUILDINGS. SEISMIC RESPONSE COEFFICIENT, Cs = 0.8088. RESPONSE MODIFICATION FACTOR, R = 1.25. ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE. DESIGN WEIGHT OF EMPTY VSU = 15,561 LBS. DESIGN MAX VSU STORAGE WEIGHT = 70,217 LBS. DESIGN VSU EFFECTIVE SEISMIC WEIGHT = 15,561 LBS + (D.67)x70,217 LBS = 62,606 LBS. DESIGN VSU DESIGN BASE SHEAR = 50,636 LBS. DESIGN VSU SIZE = 9.12' x 10.08' x 26.41' HIGH. FOUNDATIONS: FOUNDATION SHALL BEAR ON FIRM, UNDISTURBED SOIL OR CONTROLLED COMPACTED FILL. ASSUMED DESIGN SOIL BEARING VALUE = 1,500 PSF. CONCRETE: MINIMUM 28—DAY STRENGTH OF CONCRETE SHALL 4,000 PSI. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED. REINFORCING STEEL FOR CONCRETE: USE ASTM A615, GRADE 60 (FY = 60 KSI), DEFORMED BARS FOR ALL BARS. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. ACI 318 SHALL APPLY. SUPPORT OF FOUNDATION REINFORCING MUST PROVIDE ISOLATION FROM MOISTURE AND CORROSION. REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS SHALL BE PER ACI SP-66. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION WITH STANDARD 90—DEGREE HOOKS, U.N.O. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. LAP SPLICES IN CONCRETE: LAP SPLICES, U.N.O., SHALL BE CLASS "B" TENSION LAP SPLICES PER ACI 318. STAGGER SPLICES A MINIMUM OF (1) LAP LENGTH. ALL SPLICE LOCATIONS SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. REINFORCING STEEL COVER: ALL REINFORCING SHALL BE CHAIRED TO ENSURE PROPER CLEARANCES. CLEAR CONCRETE COVERAGES AS FOLLOWS: CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH• EXPOSED TO EARTH OR WEATHER #6 OR LARGER #5 AND SMALLER• ALL OTHER PER ACI 318 3" 2„ 1 1/2" ADHESIVE DOWELS: ALL ADHESIVE DOWELS SHALL UTILIZE HILTI HIT—HY 200 EPDXY (ICC ESR-3187) OR APPROVED EQUIVALENT. STRUCTURAL STEEL: ALL CONSTRUCTION SHALL BE PER AISC—SCM. ALL STRUCTURAL STEEL SHALL BE ASTM A36 (FY = 36 KSI), U.N.O. ANCHOR RODS: ALL ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 105 U.N.O. POST —INSTALLED ANCHORS ARE NOT PERMITTED. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS SHALL BE FLAGGED UPON CONTRACTOR'S REVIEW. VERIFY ALL DIMENSIONS WITH EXISTING CONSTRUCTION AND COORDINATE WITH ENGINEER. MANUFACTURER OR FABRICATOR SHALL CLOUD ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DOCUMENTS. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW, U.N.O. THE ENGINEER HAS THE RIGHT TO APPROVE OR DISAPPROVE ANY CHANGES TO CONTRACT DOCUMENTS AT ANY TIME BEFORE OR AFTER SHOP DRAWING REVIEW. THE SHOP DRAWINGS DO NOT REPLACE THE CONTRACT DOCUMENTS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER SHALL NOT BE CONSIDERED CHANGES TO CONTRACT DOCUMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ITEMS ARE CONSTRUCTED TO CONTRACT DOCUMENTS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. CONTRACTOR HAS THE RESPONSIBILITY OF THE CORRECTNESS OF ALL APPROVAL DRAWINGS. G= \=RA_ SCALE: N.T.S. S R REVISION FOUNDATIONS FOR VERTICAL STORAGE UNITS RA_ \OTIS 36396 BY SITTS APPROVED BKL DATE 08.09.19 SYM THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT ARE NOT LIMITED TO BRACING AND SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS OR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDA, U.N.O. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH EXISTING CONSTRUCTION PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ENGINEER. TYPICAL DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY, U.N.O. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND/OR SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A REGISTERED ENGINEER RECOGNIZED BY THE BUILDING CODE JURISDICTION OF THIS PROJECT. SPECIAL STRUCTURAL INSPECTION: SPECIAL INSPECTION IS TO BE PROVIDED FOR THE ITEMS LISTED BELOW IN ADDITION TO THE INSPECTIONS CONDUCTED BY THE BUILDING SAFETY DEPARTMENT. "SPECIAL STRUCTURAL INSPECTION" SHALL NOT RELIEVE THE OWNER OR THEIR AGENT FROM REQUESTING THE CITY INSPECTIONS REQUIRED BY IBC SECTION 110.3. SPECIAL INSPECTION IS REQUIRED PER SECTIONS 1704 AND 1705 FOR THE FOLLOWING: 1, CONCRETE: A) DURING THE TAKING OF TEST SPECIMENS. B) DURING THE PLACEMENT OF ALL REINFORCED CONCRETE, U.N.O. C) VERIFICATION OF CURING TEMPERATURE AND TECHNIQUE (PERIODIC). 2. BOLTS IN CONCRETE: A) DURING THE PLACING OF CONCRETE AROUND BOLTS. 3. REINFORCING STEEL (PERIODIC): A) DURING THE PLACING OF REINFORCING STEEL FOR ALL CONCRETE REQUIRED TO HAVE SPECIAL INSPECTION NOTED ABOVE. 4. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR: A) THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B) PER IBC SECTION 1704.2.4: THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND TO THE ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. SUBMIT A FINAL REPORT AS REQUIRED. C) UPON COMPLETION OF THE ASSIGNED WORK, THE ENGINEER SHALL COMPLETE AND SIGN THE APPROPRIATE FORMS CERTIFYING THAT, TO THE BEST OF THEIR KNOWLEDGE, THE WORK IS IN CONFORMANCE WITH THE APPROVED PLANS, SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. FOR ADDITIONAL INFORMATION ON SPECIAL STRUCTURAL INSPECTIONS, CONTACT STRUCTURAL ENGINEER PRIOR TO START OF CONSTRUCTION. REVISION BY APPROVED DATE VSU COLUMNS AND BASE ASSEMBLIES (24 LOCATIONS) 17'-6" \DA 0\ ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. PLA DRAWN J. Kamla CHECKED A. Boileau ENGINEER A. Boileau CHECKED DATE 05.29.19 05.29.19 05.29.19 SUBTITLE TITLE STRUCTURAL VSU ANCHORAGE PER DETAIL 1/S611, TYP, (24 LOCATIONS) 16'-6" REVIE D FOR CODE COMPLIANCE APPROVED AUG L i(319 City of Tukwila LfBUILEDING D1VISIO AUG 2019 ISSUED FOR PERMIT AUGUST 09, 2019 GENERAL STRUCTURAL NOTES AND ENLARGED PLAN FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-1 PLANT 2, WA 2. SEE DETAILS 2/S611, 3/S611, AND 4/S611 FOR TYPICAL REINFORCING DETAILS CONSTRUCTION NOTES: ► VERIFY VERTICAL STORAGE UNIT (VSU) DIMENSIONS, REQUIRED SPACE BETWEEN ADJACENT CONNECTED VSU'S, AND VSU CONNECTION WITH THE EQUIPMENT MANUFACTURER'S REPRESENTATIVE. OBTAIN THE FOLLOWING FROM THE EQUIPMENT MANUFACTURER'S REPRESENTATIVE: A. ANCHOR ROD LAYOUT DIMENSIONS. B. ALLOWABLE ANCHOR ROD PLACEMENT TOLERANCES. C. THICKNESS OF VSU COLUMN BASE ASSEMBLIES AT THE ANCHOR RODS. PROVIDE E.O.R. RED —LINED PLANS SHOWIN THE AS —BUILT ANCHOR ROD LAYOUT DIMENSIONS AND COLUMN BASE ASSEMBLY THICKNESSES. POST —INSTALLED ANCHORS ARE NOT PERMITTED FOR ATTACHING THE VSU COLUMN BASE ASSEMBLIES TO THE FOUNDATION. IF ANCHORS ARE NOT CORRECTLY LOCATED AND INSTALLED, THAT AREA OF THE FOUNDATION SHALL BE REMOVED AND RECONSTRUCTED. CONTACT E.O.R. FOR RECONSTRUCTION GUIDANCE. (2� 1S64LS610 0 2 4 8 12 SCALE: 1 /4"=1 '-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET PHONE: (253) 474-9449 I TACOMA, WA. 98409 I FAX: (253) 474-9449 www.sittshill.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SYMBOL DATE 08.09.19 SHEET 36396 COMP NO. 02-10—S610 \FRDRCKSN\24 -60C\STRUCT\S522 -8A NOTES: A. COORDINATE ANCHORAGE INSTALLATION WITH VSU COLUMN BASE ASSEMBLY. NOTES: LAP PER TYPICAL SCHEDULE #4x24" DOWELS AT 24" O.C. AT MID —DEPTH OF EXISTING SLAB, EMBED 4" IN ADHESIVE PER G.S.N. EXISTING SLAB VS=0 \DA SCALE: 1" = 1'-0" 0\ (2) #4 x 4'-0" TOP AND BOTTOM R =ORCI\ J A S S =CT 0\ PLAN _AB COR\ VSU FOUNDATION #6AT8"O.C. #6 AT 8" O.C. RE—ENTRANT SLAB CORNER SERVICE ACCESS PIT OR ADJACENT EXISTING SLAB D A COMPACT SUBGRADE TO 95% DRY DENSITY (A S610 S611 SCALE: N.T.S. REVISION BY APPROVED DATE S610 S611 SYM 7/8" DIA. ASTM F1554 GR. 105 ALL THREAD (CUT) STEEL ANCHOR 0 v W 0 oc o_ WRAP TOP 7" OF EMBEDDED ANCHOR IN MASTIC TAPE TO PREVENT BOND WITH CONCRETE ASTM A36 3" SQUARE x 5/16" THICK STEEL PLATE WASHER ASTM A563 GRADE D HEX NUT, TYP. TYP CA_ VS., A\C-ORAG SCALE: 1 1/2" = 0" REVISION REVISION BY APPROVED DATE FOUNDATIONS FOR VERTICAL STORAGE UNITS 36396 SITTS BKL 08.09.19 ASTM F844 STANDARD WASHER TOP OF VSU FOUNDATION z J 0 U PEEN THREADS, TIP. (71 S610 S611 CO R CLASS "B" LAP SPLICE LENGTH (IN INCHES) F'c=4,000 PSI REG TOP #3 20 26 26 34 #5 32 42 #6 38 50 \CR =ORCI\G LAP SPL SCALE: N.T.S. e)ijsneze-,rAvG° C SC ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. Kamla A. TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. B. UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS, WALLS, AND FOOTINGS SHALL BE CLASS "B" TENSION LAP SPLICES. C. CONTACT STRUCTURAL ENGINEER IF CENTER —TO —CENTER SPACING OF REINFORCEMENT IS LESS THAN (3) BAR DIAMETERS (<3DB). D. LAP SPLICES BASED UPON 60 KSI STEEL. (2 S610JS611 DATE SUBTITLE 05.29.19 APPROVED BY DEPT. DATE CHECKED A. Boileau ENGINEER A. Boileau CHECKED 05.29.19 05.29.19 APPROVED APPROVED TITLE STRUCTURAL 1db (1" MINIMUM) 6 MIN. 11 BAR CLEARANCE BAR OFFSET db 12db CO\CR BEND AND HOOK DETAILS �T= R= MAXIMUM 1/5 LAP I BUT NOT MORE tI THAN 6" WIRE TIES SPLICE DETAIL 4db (2 1/2" MINIMUM) INSIDE BEND RADIUS: #3 TO #8 BARS = 3db =ORC\C BAR D A SCALE: N.T.S. REVIE WD FOR CODE COMPLIANCE APPROVED AUG 27 2019 City of Tukwila BUILDING DIVISION AUG 15 2t1 „.R ISSUED FOR PERMIT AUGUST 09, 2019 FOUNDATION SECTIONS AND DETAILS FOUNDATIONS FOR VERTICAL STORAGE UNITS BUILDING 02-10 0 6" S610 S611 2 SCALE: 1 1 /2"=1 '-0" 0 6" 1 2 3 SCALE: 1 "=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 www.sittshill.com Project No.: 18391 Project Mgr.: BKL Proj. Engineer: AJB Proj. Drafter: JDK CURRENT REVISION 36396 SYMBOL DATE 08.09.19 SHEET S611 COMP NO. 1 :\FRDRCKSN\24-60C\STRUCT\S522-8A