HomeMy WebLinkAboutPermit D19-0296 - SUNRISE GARDEN SUITES / BUILDING J - REROOFSUNRISE GARDEN SUITES -
BLDG J REROOF
14800 INTERURBAN AVE S
BLDG 10
D19-0296
Parcel No:
Address:
Project Name:
0
City of Tukwila
Department of Community Development
6300 SouthcenterBoulevard, Suite w1UU
Tukwila, Washington 9B188
Phone: 206-x 1'3670
Inspection Request Line: 206'438'9350
Web site: http://www.TukwilaWA.Rov
3597000005
DEVELOPMENT PERMIT
Permit Number:
l48UOINTERURBAN AVE 5BLDGlD Issue Date:
Permit Expires On:
Owner:
JDA PROPERTY MANAGEMENT
128195[38TM%T#282'DELLEVUE,
WA, 98006
Contact Person:
Name: GUSTAVO MERCADO LOPEZ
Contractor:
30542FOURTH AVE SW, FEDERAL
WAY, WA, 98025
TAVI'S ROOFING SERVICE LLC
Address: 305424TMAVE SW, FEDERAL WAY,
VVA,9nV23
License No: TAx8RS844{lm
Lender:
Name: SUNRISE GARDEN SUITES
Address 148UOINTERURBAN AVE S'TUKVV|b\
WA, 98168
Phone: (253)217-0944
Phone: (253)217-0944
Expiration Date:
DESCRIPTION QFWORK:
TEAR OF EXISTING ROOF, REPLACE PLYWOOD AS NEEDED, INSTALL 30# FELT, PLUMB CUT RAFTERS TO ALLOW
FOR FASCIA INSTALLATION AND INSTALL NEW LAMINATED SHINGLESProject Valuation: $31,000.00
Type ofFire Protection: Sprinklers:
Fire Alarm:
Type oyConstruction: VB
Electrical Service Provided by: TUKWILA
Fees Collected: $1,225.32
Occupancy per IBC: R'2
Water District: TUKVV|LA
Sewer District: TUKVV|LA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
international Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
VVACities Electrical Code:
VVACZ96-46B:
Code:
Public Works Activities:
Chan neUzadon/Sthping -
Curb[ut/Access/Sidewe|k:
Fire Loop Hydrant:
Flood Control Zone:
Hau|ing/OveoizeLnad:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signa
Volumes: Cut: O Fill: O
Number: O
No
Date: ^0 - ) —1 q
|hearbycertify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancelthe provisions ofany other
state or local laws regulating construction or the performance nfwork. | am authorized to sign and obtain this
development permit andagree tothe conditions attached tothis permit.
h^ ��
Signature: �/v'(r`~ ' ^w=�cn�u� Gqc;rt
Print Name: Rr Ca or,
This permit shall become null and void if the work isnot commenced within l80days for the date nfissuance, orif
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: 'BUILDING PERMIT CONDITIONS'
2: Work shall beinstalled inaccordance with the approved construction dncuments,andanychan0esmode
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
]: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
S; Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
onsatisfactory completion ofthis requirement.
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. Aoopy
can beobtained atCity Hall inthe office of the City Clerk.
7: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty
certificate shall bpprovided tothe building inspector.
8: VALIDITY OFPERMIT: The issuance or granting ofapermit shall not be construed to beapermit for, man
approval of, any violation ofany cf the provisions ofthe building code ornfany other ordinances ofthe City
of Tukwila, Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based nmconstruction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206)43[-g35D
1700 BU|LD|mGF|NAL^~
UlO] PRE'REROOF
CITY OF TUKCLI4
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building POit No. UN fr
Project No.
Date Application Accepted: °I
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail.
**Please Print**
SITE INFORMATION
Site Address: /y600
Tenant Name:
6-v g
PROPERTY OWNER
Name:
Address:
City:
State:
Zip:
CONTACT PERSON — person receiving all project communication
Name: Q5
ift tk
ca., Jo
Laic 6
Address: 301,
y
• s t.J
City: 7:-jcztvi
vai
State: ("kJ k
Zip:
Phone: (4) 517 )
j 7_
07 y if
Email: T .y.
CiW5
niorirli e Va. oc). Cei-t
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
Name:
Address:
City:
State:
Zip:
Phone:
Email:
GENERAL CONTRACTOR INFORMATION
Company Name: To _-
, Uf 5 rod FA 5
cei-occ.c tAt
Address:
City: State: State:
Zip:
Phone:
St Contr Reg &To, 45..tts eyq cps/
Exp Date:fi_ is,. 2.
Tukwila Business License No.:
King Co Assessor's Tax No.:
Suite Number: Floor:
to
New Tenant: D..Yes No
ARCHITECT OF RECORD
Company Name:
Address:
City:
State:
Zip:
Phone:
Email:
ENGINEER OF RECORD
Company Name:
Address:
City:
State:
Zip:
Phone:
Email:
LENDER — WHO IS FUNDING THE PROJECT
(required for projects $5,000 or greater per RCW 19.27.095)
Name:
...)1, j'INT 1 .sc_ e n 5LJeS
Address:
City: State: Zip:
MONTHLY SERVICE BILLING -or- WATER METER
REFUND/BILLING
Name:
Address:
City:
State:
Zip:
Phone:
W:\Permit Center (Rachelle)Applications\ Word \Construction Permit Application Revised 6-2019.docx
Revised: June 2019
Page I of 3
BUILDING DIVISION JNFORMATiN — 206-4 - 670
Valuation of Project (contractor's bid price): $ 11000
Describe the scope of work (please provide detailed information): '7 c r Orr -004 rtl v--00E, rrif tr. p iyurdro
rx..c.e40 , 105 WI 4t (-eitf. co off £13-t 6 (-'• raf+ers S-roi'L?U i NrAi
Fo,scAL Vow) IA14-0.0 Lo...r,,,fkol-eal LT ,5) cs
Will there be new rack storage? Yes
Existing Building Valuation: $
LI ..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
2"d Floor
3'd Floor
Floors thru
Basement
Accessory Structure*
Garage
0 Attached El Detached
Carport
0 Attached El Detached
Covered Deck
Uncovered Deck
PLANNING DIVISION INFORMATION — 206-431-3670
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use?
Yes
No
Compact:
Handicap:
If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS — 206-575-4407
0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 ..... .. Yes 0 .......No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
PUBLIC WORKS INFORMATION — 206-433-0179
D Permanent Water Meter Size ( I )
• Temporary Water Meter Size (I)
O .. Water Only Meter Size 3/
o Sewer Main Extension Public
It
WO # (2) " WO # (3) " WO #
WO # (2) " WO # (3) " WO #
WO # El ... ..... Deduct Water Meter Size „
Private 0 0.. Water Main Extension Public 0 Private 0
WAPermit Center (Racttelle)\Applications \Word \Construction Permit Application Revised 6-2019.docx
Revised: June 2019
Page 2 of 3
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: JSTfrvo Meit-oknu i.qCUZ.
Print Name:
Mailing Address: IG,Y jC0F1+xy CD tiA00 t y
Date: 7 — �y
Day Telephone:
City
State Zip
W:\Permit Center (Raehelle)\Applications\Word \Construction Permit Application Revised 6-2019.docx
Revised: June 2019
Page 3 of 3
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT
PermitTRAK
QUANTITY PAID
$3,074.01
D19-0295 Address: 14800 INTERURBAN AVE S COMPLEX Apn: 3597000005 $1,225.32
DEVELOPMENT
$1,190.02
PERMIT FEE
R000.322.100.00.00
0.00
$706.07
PLAN CHECK FEE
R000.345.830.00.00
0.00
$458.95
WASHINGTON STATE SURCHARGE
8640.237.114
0.00
$25.00
TECHNOLOGY FEE
$35.30
TECHNOLOGY FEE
R000.322,900.04.00
1 0.00
$35.30
D19-0296 Address: 14800 INTERURBAN AVE S COMPLEX Apn: 3597000005 $1,225.32
DEVELOPMENT
$1,190,02
PERMIT FEE
R000.322.100.00.00
0.00
$706.07
PLAN CHECK FEE
R000.345,830.00.00
0.00
$458.95
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$25.00
TECHNOLOGY FEE
$35.30
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$35.30
D19-0297 Address: 14800 INTERURBAN AVE S COMPLEX Apn: 3597000005 $623.37
DEVELOPMENT
$605.77
PERMIT FEE
R000.322.100.00.00
0.00
$351.98
PLAN CHECK FEE
R000.345.830.00.00
0.00
$228.79
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$25.00
TECHNOLOGY FEE
$17.60
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R18550
R000.322.900.04.00
0.00 $17.60
' $3,074.01
Date Paid: Thursday, September 12, 2019
Paid By: TAVI'S ROOFING SERVICE LLC
Pay Method: CHECK 1198
Printed: Thursday, September 12, 2019 10:32 AM 1 of 1
r.ST S
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit LAI (>216
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43 670
Permit Inspection Request Line (206) 438-9350
Project: . 'Ty
4r1S-er-- Gikerrier USkegc
e of I
e n:
)
Address:
iii twig -ritiAgemedipitsi At-5 a
Date Called:
Special Instructions:
bate Wanted: a.m.
— P-m-
09' J
Z --Z—
(PC,- irt,0 ir)
Requester:
Phone No:
[]Approved per applicable codes.
ections required prior to approvaL
COMMENTS:
n pector:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspe lon. ee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION N0. PERMIT N0,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
1
Project:..
S'v. /}gam C n ' .� 1T $'
Type of Inspection:
PRE RtrAcc
Address:
lY4300 nirEKV
Date Called:
Special Instructions: -BLDG, to
V LO
Date t`anted:
'
j
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS
Inspector:
Date:
C� 1< %%"
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
7128/2018
S RISE GARDEN
SUITES
DTOP UNITS
0:LOWWER UNITS
• ?,
Jitlg t4U
„ A
rj1
PROPERTY MARpng
4•••••••••..y..........•
SEPARATE PERMIT
UIRED FOR:
RI
Mechanical
Electrical
Plumbing
' Gas Piping
Cly of Tukwila
BUILDING DIVISION
RE, SIGNS
No risriaii • dile io ine scope
oi vOrAlinoul 2 3:)10101a,
Division
NOTE: Revisions will requite a new al
.r
plon
miq . NO.
Plan (pew approval IS stied to errors ana
ns Approvel Or construction ommonts
rr aulturnze the violation of any Noled Me or
rdniance Remo oi aporovel Fla Cop and
tons is a so'
?te /0-01
CIv Di foga
)1vISION
REVIEWED OR
CODE COMPLIANCE
APPROVED
SEP 27 019
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
SEP 12 i019
PERMIT CENTER
2,9
CERTAINTEED'S OBLIGATIONS, RESPONSIBILITIES, AND LIABILITY SHALL BE LIMITED TO
REPAIRING OR REPLACING THE DEFECTIVE PRODUCT OR CLEANING ALGAE -RESISTANT
SHINGLES IN THE CASE OF ALGAE GROWTH AS SET FORTH IN THIS LIMITED WARRANTY.
IN NO EVENT SHALL CERTAINTEED BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE PROPERTY,
THE BUILDING OR ITS CONTENTS; OR FOR INJURY TO ANY PERSONS, THAT MAY OCCUR AS
A RESULT OF THE USE OF CERTAINTEED'S PRODUCTS OR AS A RESULT OF THE BREACH
OF THIS WARRANTY. IF YOUR STATE OR PROVINCE DOES NOT ALLOW EXCLUSIONS OR
LIMITATIONS OF SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, THE
ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
IN NO EVENT SHALL CERTAINTEED'S TOTAL LIABILITY ARISING OUT OF OR RELATED TO THE
PRODUCTS) OR THIS LIMITED WARRANTY EXCEED THE REASONABLE COST OF SHINGLES
AND LABOR TO REPLACE OR REPAIR THE DEFECTIVE SHINGLES.
This Limited Warranty may not be modified, altered or expanded by anyone, including
product distributors, dealers, sellers andlor CertainTeed field representatives.
This Limited Warranty gives you specific legal rights, and you may also have other rights
which vary from State to State, or Province to Province.
Roofing Plants and Regional Sales Office
CertainTeed roofing products are sold by CertainTeed Roofing in nine sales regions. They are
manufactured in ten residential roofing plants and one commercial roofing plant. Since the early
1900s, CertainTeed Corporation has been an innovator in the building materials industry and
today is a leading manufacturer of building materials including residential and commercial
roofing, vinyl siding, composite decking and railing, fiber glass insulation and vinyl fence products.
The company is headquartered In Malvern, Pennsylvania, and employs more than 7,000
employees at approximately 60 manufacturing facilities throughout North America, Continuing
the 100-year commitment of "Quality made certain, Satisfaction guaranteed'," CertainTeed
remains one of the most trusted names in the industry. More Information is available at
www•certainteed.com,
This document is also available in Spanish and French.
Call 1-800-782-8777 or go to www.certainteed.com.
Se puede obtener este documento en espanol. Favor de (lamer 1-800-782-8777.
Ce document eat disponible en anglais et en espagnol. Compasez ie 1-800-782-8777.
SAINT-GOBAIN
CertainTeed Corporation
ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • GYPSUM • CEILINGS • INSULATION
20 Moores Road Malvern, PA 19355
Professional: 800.233.8990 Consmner: 800-782-8777 certainteed.com
Olil9 (Eilsi➢TPUI (000idlisfi, Priolpd In the DS1, (eda Ns.20-20-1,13
ASPHALT
SHINGLE PRODUCTS
2019 Limited Warranty
CertainTeed
SAINTGO8AIN
Congratulations„. and thank you for your recent purchase of one of the fine products from
CertainTeed Roofing, Since 1904, CertainTeed has been producing quality roofing products that
provide long-lasting beauty and protection for homes of every size, style and age. For over 100
years, the basis for our name, "Quality made certain, satisfaction guaranteed," has been our
ongoing philosophy.
Your CertainTeed roofing warranty fully explains how CertainTeed supports its products with the
strongest warranty protection available. It Is Important that you read the warranty section of this
brochure. The warranty lists the specific CertainTeed asphalt shingle products that are covered
and the period of time for which they are covered. Take the time to understand how CertainTeed
protects your purchase by standing behind our products.
Limited, Prorated and Transferable Warranty
This warranty covers asphalt shingle products listed in Table 1, sold only in the United States of
America, its territories and Canada.
What and Who Are Covered and for How Long
From the date of installation, CertainTeed warrants to the original property owner/consumer
that, when subject to normal and proper use, its shingles will be free from manufacturing defects
for the warranty period specified in Table 1, CertainTeed will pay to repair, replace or clean, at
its option, any shingles CertainTeed determines are defective under the terms of this Limited
Warranty. In the event of repair, replacement or cleaning pursuant to the terms of this Limited
Warranty, the warranty applicable to the original shingles shall apply to the repaired, replaced
or cleaned shingles and will extend for the balance of the original warranty period,
Lifetime means for as long as the original Individual property owner owns the property where the
shingles are installed,
The Lifetime warranty period offered for certain shingles in Table 1 is only available to individual
property owners, The warranty period for shingles installed on premises not used by individual
property owners as their residence is limited as specified In Table 1, All property owners, who
are not individual property owners, and all structures not used by individual property owners as
their residence (e.g. corporations, governmental agencies, partnerships, religious organizations,
schools, condominiums, property owner associations or cooperative housing arrangements,
apartment buildings, and any other type of building or premises not owned by individual prop-
erty owners) called "Other Ownership" are limited to either a 50-year or 40-year warranty period
described in Table 1. In addition, for Other Ownership after the SureStart Protection period
ends, this Limited Warranty covers only manufacturing defects that caused water penetration.
SureStartTM Protection
Because CertainTeed roofing products are manufactured to the highest quality standards,
we confidently include the additional assurance of SureStart protection. SureStart provides
the strongest non -prorated protection you can get in the vital early years of your new roof.
All of CertainTeed's shingle products are covered by SureStart protection. Under thls warranty
feature, CertainTeed, at no charge, will pay to repair or replace, at its option, any shingles
CertainTeed determines are defective during the SureStart period. Note: Wind warranty and
algae warranty are covered separately as described on page 5. The SureStart period begins
on the date of application and terminates following the warranty period specified in Table 1.
CertainTeed's maximum liability under SureStart is equal to the reasonable cost of comparable
replacement shingles and labor as determined by CertainTeed to replace or repair the defective
shingles. Roof tear -off, metal work, flashing and disposal expenses, and other costs or expenses
incurred during such repair or replacement are not covered or reimbursed by this Limited
Warranty, except for certain products with Lifetime warranty periods specified in Table 1,
for which CertainTeed's maximum liability also includes the cost of roof tear -off, metal work,
flashing and disposal.
In instances in which CertainTeed, under the terms of this warranty, has agreed to pay the
reasonable cost of labor required to repair or replace defective shingles, CertainTeed will
determine labor costs by Bluebookor RS Means' data. CertainTeed will provide reimbursement
for labor only upon receipt of a copy of the contractor's invoice or other written evidence of the
Completion of such work which CertainTeed, in its sole discretion, deems acceptable.
at CertainTeed's sole discretion, repair or replace the roof membrane materials only as necessary
to restore it to a watertight condition,
Only manufacturing defects in the roof membrane that cause leaks are covered by this Limited
Warranty, CertainTeed's MAXIMUM LIABILITY during the first year of this warranty is the original
cost of the CertainTeed membrane materials only, After the first year, CertainTeed's maximum
liability Is the original cost of the CertainTeed materials used on the roof reduced by 8.3% for
12-year warranty and 10% for 10-year warranty during each subsequent year, less any costs
previously incurred by CertainTeed for repair or replacements.
Roof components which are not part of the roof membrane and hence not covered by this
Limited Warranty include, but are not limited to, the following: underlying roof deck, insulation,
vapor retarders, fasteners, metal work, drains, pitch pans, expansion joints, skylights, vents,
plastic accessories, any flashing, decorative or reflective coating, surfacing and/or any
aggregates. In no event, however, will CertainTeed be responsible for any costs related to
the removal or abatement of any asbestos present in any existing roof system to which the
CertainTeed roof membrane is applied,
What the Customer Must Do
If you believe your shingles have a manufacturing defect, you must notify CertainTeed within 30
days of discovery and provide proof of property ownership and the date of shingle purchase and
application. Without original or sufficient proof of purchase CertainTeed reserves the right to use
the shingle manufacturing date for claim calculation. In order to properly evaluate and process
a warranty claim, CertainTeed may require the property owner to submit a shingle sample to
CertainTeed for analysis and/or perrnit a CertainTeed representative to make repairs to, take
photographs of, and/or take samples from the roof, if required. CertainTeed will evaluate each
properly reported claim and will repair, replace, clean or reimburse the property owner for the
shingles It determines are defective, in accordance with the terms of this Limited Warranty within
a reasonable amount of time. For more details about submitting a warranty claim, visit www,
ctroof.com or call (800) 345-1145,
Please send all notifications and correspondence to:
CertainTeed Corporation, 1508 Delp Drive, Harleysville, PA 19438.
Attn: CertainTeed Roofing Technical Services Department, Telephone number: 800-345.1145.
Warranty Registration (not required)
You may register your product warranty on CertainTeed's website:
www.certainteed.com/warrantyreg. Each registrant receives a registration confirmation number
by return e-mail that can be printed and kept with this Limited Warranty and your proof of
purchase, If you do not have internet access, you can register your shingles by sending: (1) your
name, address, and telephone number; (2) the name and contact information of the contractor
who installed your shingles and the original date of installation; and, (3) the type, color and
number of squares of your shingles to: CertainTeed Corporation, 20 Moores Road, Malvern,
PA 19355, Attn: CertainTeed Roofing Technical Services Department.
CertainTeed will register your information and mail you a confirmation number,
Failure to register this warranty does NOT void the warranty or any of its terms,
For Your Records
Product Purchased: 0 1/ U Date of Installation: 0
Roofing Contractor:TM/IS 11.0)9FIA5 Rri4ntractor's Telephone No. 151-
This warranty applies to shingles installed during the calendar year of 2019,
(The warranty in effect at the time the material is originally installed is the applicable warranty,)
5 I
Exclusive Warranty and Limitation of Remedies
THIS DOCUMENT CONSTITUTES THE EXCLUSIVE WARRANTIES AND REMEDIES PROVIDED
BY CERTAINTEED. THE WARRANTIES AND REMEDIES CONTAINED IN THIS DOCUMENT ARE
EXPRESSLY IN LIEU OF ANY AND ALL OTHER OBLIGATIONS, GUARANTEES, WARRANTIES
AND REPRESENTATIONS, WHETHER WRITTEN, ORAL OR IMPLIED BY STATUTE, AT LAW OR IN
EQUITY, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. SOME STATES OR PROVINCES MAY NOT
ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR MAY DETERMINE THE PERIOD OF
TIME FOLLOWING THE SALE THAT A PURCHASER MAY SEEK A REMEDY UNDER IMPLIED
WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU,
6
Limited Algae -Resistant Warranty
Blue-green algae or gloeocapsa magma, (which has a black/brown appearance and is commonly
but incorrectly called "fungus"), can create unsightly streaking on shingles. CertainTeed warrants
that the Algae -Resistant (AR) versions of the products in Table 1 will remain free from blue-green
algae growth (but not mold or mildew growth) which adversely affects the overall appearance of
said shingles for a period of ten (10) or fifteen (15) years, as noted in Table 1.
If during the Algae -Resistant Warranty Period specified in Table 1, the overall appearance
of the Algae -Resistant shingles is adversely affected by blue-green algae, CertainTeed will
pay the reasonable cost to replace or clean at its option, any affected shingles, In the event
of replacement or cleaning, for the remainder of the Algae -Resistant Warranty Period,
CertainTeed's maximum contribution towards subsequent replacement or cleaning will be
calculated using the Algae -Resistant Warranty Period specified in Table 1, less a prorated
adjustment that reflects the number of months that have elapsed from the start of the
Algae -Resistant Warranty Period to the date of reoccurrence,
WARNING: FOR LOWVOLUME RAIN AND SALT FOG AREAS
In areas of low -volume rain (e.g. areas that receive insignificant rainfall during a 90-day
period) and/or 'salt fog" (e.g. parts of the Southem California coastline), copper released by
algae -resistant (AR) granules or shingles can react with aluminum in gutters and cause severe
corrosion of the gutters. In such regions, CertainTeed strongly recommends that vinyl or copper
gutters, not aluminum gutters, be used with algae -resistant shingles, CertainTeed disclaims all
liability and responsibility for any damages that may result from the use of its algae -resistant
shingle products with copper granules where gutters containing aluminum are used.
Limited Wind Warranty
CertainTeed warrants its shingles will resist blow -off damage due to wind velocities, including
gusts, up to the maximum wind velocity per the Wind Warranty MPH specified in Table 1 during
the first fifteen (15) years of the warranty for Lifetime products and during the first ten (10) years
for Patriot shingles and during the first five (5) years for all other products listed in Table 1.
CertainTeed's obligations and liability for shingle blow -off damage during the wind warranty
periods as specified above are limited as follows:
• If shingles or hip/ridge accessories blow off because the self-sealing asphalt strips did not
activate, CertainTeed will furnish replacement shingles without charge, but only for damaged
or blown off shingles.
" If shingles or hip/ridge accessories blow off before the self-sealing asphalt strips could have
reasonably activated due to installation in cold weather, CertainTeed will furnish replacement
shingles without charge, but only for damaged or blown off shingles. CertainTeed will not
be responsible for or reimburse labor costs, roof tear -off, metal work, flashing and disposal
expenses, or any other costs pertaining to removal or replacement of damaged shingles, Any
costs in excess of CertainTeed's material contribution are the property owner's responsibility
(and may be covered by owner's insurance).
CertainTeed shall have no liability for any shingles not fastened in accordance with CertainTeed
installation instructions published at the time of original installation.
" CertainTeed shall have no liability for any damage to persons or property caused by blown
off shingles.
CertainTeed's maximum liability during the Limited Wind Warranty period is the reasonable
cost of hand sealing all of the shingles on the roof,
Flintlastic® SA (Self -Adhering) System
For low slope residential roofing projects less than 2000 square feet (20 squares), CertainTeed
offers a limited roof membrane warranty as follows: A 10-year warranty duration on a single
ply of Flintlastic SA Cap sheet over a primed plywood roof deck or a 12-year warranty duration
for a two-ply system consisting of a Flintlastic SA Nail Base and a Flintlastic SA Cap sheet,
provided the Flintlastic products were applied in accordance with CertainTeed's current
installation instructions published at the time of installation.
CertainTeed warrants the roof membrane, subject to the following terms, conditions, limitations,
and exclusions, for the duration specified above from the date of completion of the roof
membrane installation. If during the duration of this Limited Warranty, a manufacturing defect
in the roof membrane causes a leak, CertainTeed or its designated roofing contractor will,
Costs associated with removal or replacement of overburden (items installed over the shingles,
including but not limited to, solar panels, satellite dishes and gardens) are the sole responsibility
of the property owner.
SureStart protection does not extend to any shingles applied to non -ventilated or inadequately
ventilated roof deck systems as determined by CertainTeed, except as stated on page 4.
CertainTeed's maximum contribution toward the cost of repairing or replacing defective shingles
applied to a non -ventilated or inadequately ventilated roof deck system is calculated using the
reasonable cost of comparable replacement shingles as determined by CertainTeed less 1/120th
of that amount multiplied by the number of months from the start of the warranty period to the
date when CertainTeed determines the shingles are defective. Labor costs, roof tear -off, metal
work, flashing and disposal expenses, and other costs or expenses incurred during such repair
or replacement are not covered or reimbursed by this Limited Warranty,
Beyond SureStart®M Protection
After the SureStart Protection period, if CertainTeed determines its shingles have a manufactur-
ing defect, or for Other Ownership, if CertainTeed determines its shingles have a manufacturing
defect that caused water penetration, CertainTeed's maximum contribution toward the cost
of repairing or replacing defective shingles will be calculated using the reasonable cost of
comparable replacement shingles as determined by CertainTeed less the Reduction Figure
Per Month, specified in Table 1, for the number of months from the start of the warranty period
to the date when CertainTeed determines the shingles are defective. Labor costs, roof tear -off,
metal work, flashing and disposal expenses, and other costs or expenses incurred during such
repair or replacement are not covered or reimbursed by this Limited Warranty,
TABLE 1
Algae
Wind Resistant Reduction
Warranty SureStart Warranty Warranty Figure
Lifetime Products', period Period Miles Per Hour Period' Per Month
Grand Manor®
Arcadia Shake'
Presidential Shake® TL
Presidential Solaris'
Landmark® TL
Presidential Shake® (& IR)2
Carriage House'® Lifetime" 10 Years 110" 15 1/600*
Belmont'(& IR)2
Landmark' Premium
Landmark Solaris'
Landrnark® PRO
NorthGate®
Highland Slate® (& I18)2
Wind
Warranty SureStart Warranty
Lifetime Productse Period Period Miles Per Hour
Landmark® IA2 Lifetime, 10 Years 110"
Landmark® Lifetime, 10 Years 110"
Algae
Resistant
Warranty
Period'
10
10
Reduction
Figure
Per Month
1/600*
1/600"
Algae
Wind Resistant Reduction
20 •, 25 • and Warranty SureStart Warranty Warranty Figure
09 • Year Products Period rind Miles Per Hour Period' Per Month
Patriot 30 Years 8 Years 110 10 1/360
XT'"30 IR2 30 Years 5 Years 70 10 1/360
XT"252 25 Years 5 Years 60 10 1/300
CT'20 20 Years 3 Years 60 1/240
Any shingles applied to any 10 years'
inadequately ventilated roof deck
(see footnotes to Table 1 on the next page)
N/A NIA N/A 1/120
FOOTNOTES TO TABLE 1,
A. The Lifetime Warranty period is only available to individual property owners on premises used as their residence.
The warranty period for Other Ownership for these shingles is limited to 50 years and the SureStart period is 10 years
following the installation of the shingles. Roof tear -off, metal work, flashing and disposal expense, incurred during repair
or replacement are covered or reimbursed by this Limited Warranty. Limited Warranty transferees during the SureStart'"
period are limited to a 50-year warranty period (see section titled "Transfers During the SureStart Period" for details).
B. The Lifetime Warranty period is only available to individual property owners on premises used as their residence.
The warranty period for Other Ownership for these shingles is limited to 40 years and the SureStart period is 5 years
following the installation of the shingles. Limited Warranty transferees during the SureStart period are limited to a 40-year
warranty period (see section titled "Transfers During the SureStart Period" for details).
For Lifetime products, at the completion of the 40th year the reduction figure will remain at 4801600, or 20°% of the total
maximum liability.
t For details of warranty coverage for shingles installed on inadequately ventilated roof decks on both residential and
commercial buildings, see provisions under "Inadequately Ventilated and Non -Ventilated Decks,"
ft Wind warranty upgrade - These products are warranted to resist blow -off due to wind velocities, including gusts, up to
a maximum of 130 miles per hour during the first fifteen (15) years, provided all of the following conditions are met:
1. The CertainTeed shingles are not applied over existing roof shingles (root-overs are not permitted).
2. The CertainTeed specified corresponding hip and ridge accessory products are installed as cap shingles
[Shadow Ridge', Cedar Crest*, Shangle Ridge", Mountain Ridge' and Landmark Solaris'(&
3. The CertainTeed specified corresponding starter shingles are installed along the roof eaves and rakes
(Swiflstart°, High•Performance Starter and Presidential' Starter).
(Note: In Florida, CertainTeed will waive the requirement of applying starter shingles along the roof rake if all of the
following conditions are met: The applicable building code requires that asphalt roof shingles be embedded in an
8-inch•wide bed of asphalt roofing cement applied along the roof rake edges. And, the shingles are installed and
embedded in an 8-inch-wide bed of asphalt roofing cement along the roof rake edges in accordance with the code.)
'Algae Resistant Warranty period applies only to the Algae Resistant (AR) version of the pertinent shingle,
2CertainTeed's Impact Resistant (IR) versions of Landmark', Presidential Shake°, Belmont', Highland Slate°, and XT'30
shingles comply with UL 2218 Impact Resistance of Prepared Roof Covering Materials test criteria at time of manufacture.
21he wind warranty for XT"25 shingles installed in Alaska is 90 mph.
Transferability
This Limited Warranty is transferable, but only by the original property owner/consumer to the first
subsequent property owner. After the Limited Warranty has been transferred once, it is no longer
transferable. A bank foreclosure or a change of ownership on a deed is deemed a transfer under
this Limited Warranty.
Transfers During the SureStart'" Period
If this Limited Warranty is transferred during the product's SureStart period, the warranty for the
new owner is the same as it would have been for the original owner, except for certain products
with Lifetime warranty periods where the duration of the transferred warranty will be 50 years
or 40 years as specified in Table 1, measured from the beginning of the SureStart period
(i,e, the date of installation), and the remaining period of SureStart protection will be available
to the subsequent property owner.
Transfers After the SureStart Period
If this Limited Warranty is transferred by the original property owner/consumer after the SureStart
period, the warranty following the transfer will be limited to two (2) years from the date of the
transfer. The warranty obligation will be calculated as explained in the section titled "Beyond
SureStart Protection."
Limitations
This Limited Warranty does not provide protection against, and CertainTeed will have no liability
for, any failure, defect or damage as a result of, including but not limited to:
• Winds, including gusts, greater than the Wind Warranty MPH in Table 1
• Damage caused by lightning, hailstorm, earthquake, fire, explosion, flood or falling objects.
• Damage caused by tornado, or hurricanes (other than as warranted under Wind Warranty MPH
in Table 1).
• Distortion, cracking or other failure or movement of: the base material over which the shingles
are applied, the roof deck, or the walls or foundation of the building itself.
• Damage caused by structural changes, alterations or additions, or by the installation of
equipment (such as, but not limited to, aerials, signs or air-conditioning equipment) to the
building after the original shingles have been applied.
• Shading, stains or discoloration to the shingles arising from outside sources such as, but not
limited to, algae (unless blue-green algae as described in the section titled "Limited Algae
Resistant Warranty"), fungus, moss, lichens or other vegetation, mold or mildew growth, or
paints, chemicals or other similar materials.
• Misuse, abuse, neglect, or improper transportation, handling or storage of the shingles.
• Installation of the shingles over non -approved roof decks as more fully explained in
CertainTeed's installation instructions published at the time of original installation.
• Damage caused by improper installation or installation not in accordance with CertainTeed's
installation instructions published at the time of original installation.
• Damage to the shingles, the roof deck or the structure caused by ice backup or ice damming.
• Damage caused by Impact, including such things as tools, equipment or foot traffic.
• Vandalism or acts of war.
• Animals, animal feces or insects.
• Any other cause not a result of a manufacturing defect in the shingles.
Mold and mildew are functions of environmental conditions and are not manufacturing defects.
As such, mold and mildew are not covered by this Limited Warranty or any implied warranty.
CertainTeed reserves the right to discontinue or modify any of its products, including the color
of its shingles, and shall not be liable as a result of such discontinuance or modification, nor
shall CertainTeed be liable in the event replacement material varies in color in comparison to
the original product as a result of normal weathering. If CertainTeed replaces any material under
this warranty, it may substitute products designated by CertainTeed to be of comparable quality
or price range in the event the product initially installed has been discontinued or modified.
Inadequately Ventilated and Non -Ventilated Decks
Any shingles applied to inadequately ventilated or non -ventilated decks, other than the shingles
and deck systems described In the section titled "Insulated Decks and Radiant Barriers," are
subject to a reduced limited warranty period of ten (10) years and do not qualify for SureStart
Protection. SureStart" Protection and the Warranty Period applicable to the shingle are
available if CertainTeed determines that the shingle damage was caused exclusively by a
manufacturing defect that is unrelated to the inadequate roof system ventilation.
Insulated Decks and Radiant Barriers
CertainTeed's Limited Warranty, including SureStart Protection, will remain in force when its
fiberglass shingles are applied to roof deck assemblies where foam insulation is prefabricated
into the roof deck system (often called "nailboard insulation"), where insulation is installed
beneath an acceptable roof deck system, or where radiant barriers are installed, with or without
ventilation, directly below the deck. Acceptable roof deck surfaces must consist of at least 3/8"
thick plywood or 7/16" thick Oriented Strand Board (OSB) and slopes must be 2:12 or greater.
If a different deck surface material will be utilized, please contact CertainTeed's Technical
Services Department for assistance. (See the following important restrictions.)
The design professional is responsible for ensuring: 1) the proper quality and application of
the insulation and/or radiant barrier, 2) the provision of adequate structural ventilation and/or
vapor retarders as determined to be necessary, and 3) that all local codes are met (particularly
taking into account local climate conditions). Special attention must be taken if cellular foam,
fiberglass, cellulose insulation or other highly permeable insulation will be used in an unventilated
system, or if the insulationlrafter or insulation(joist planes may create an air leak that could lead
to moisture transmission and condensation problems. All these important factors and decisions,
while not the responsibility of CertainTeed, are critical to assure proper deck system performance.
Ventilated Nail -Base Roof Insulation
Ventilated Nail -Base Roof Insulation products (e.g. FlintBoard' CV) are made of rigid insulation
(typically foam board) and another layer of material that provides air space above the insulation
and below the nailable deck (which is typically at least 7/16° thick OSB or 3/8" thick plywood).
These products can provide soffit -to -ridge ventilation, and if installed in accordance with the
deck manufacturer's instructions to achieve sufficient ventilation, will not reduce the scope or
length of CertainTeed's Limited Warranty coverage.
Technical Data Sheet
Landmark® Premium Shingles
Landmark® PRO/Architect 80 Shingles (NW Region only)
Landmark® PRO Shingles
Landmark® Shingles
PRODUCT INFORMATION
Landmark shingles reflect the same high manufacturing standards
and superior warranty protection as the rest of CertainTeed's line of
roofing products. Landmark Premium (and Algae Resistant -AR),
Landmark PRO (and AR) and Landmark (and AR) are built with the
industry's toughest fiber glass mat base, and their strict dimensional
tolerance assures consistency. Complex granule color blends and
subtle shadow lines produce a distinctive color selection. Landmark is produced with the unique NailTrak®
nailing feature. Please see the installation instruction section below for important information
regarding NailTrak.
In the Northwest Region Landmark PRO (AR) is double -branded as Landmark PRO/Architect 80 (AR).
Landmark algae -resistant (AR) shingles have the additional attribute of resisting the growth of algae
especially in damp regions. AR shingles are not available in all regions
Colors: Please refer to the product brochure or CertainTeed website for the colors available in your
region.
Limitations: Use on roofs with slopes greater than 2" per foot. Low -slope applications (2" to 4" per foot)
require additional underlayment. In areas where icing along eaves can cause the back-up of water, apply
CertainTeed WinterGuard® Waterproofing Shingle Underlayment, or its equivalent, according to
application instructions provided with the product and on the shingle package.
Product Composition: Landmark Series shingles are composed of a fiber glass mat base. Ceramic -
coated mineral granules are tightly embedded in carefully refined, water-resistant asphalt. Two pieces of
the shingle are firmly laminated together in a special, tough asphaltic cement. All Landmark shingles have
self-sealing adhesive strips.
Applicable Standards
ASTM D3018 Type I
ASTM D3462
ASTM E108 Class A Fire Resistance
ASTM D3161 Class F Wind Resistance
ASTM D7158 Class H Wind Resistance
UL 790 Class A Fire Resistance
Technical Data:
Weight/Square (approx.)
Dimensions (overall)
Shingles/Square (approx.)
Weather Exposure
Landmark
(and AR)
222 / 238 lb **
13 1/4" x 38 3/4"
66
5 5/8"
*Includes Landmark PRO AR/Architect 80
**Dependent on manufacturing location
ICC-ES ESR-1389 and ESR-3537
CSA Standard A123.5 (Regional)
Miami -Dade Product Control Approved
Florida Product Approval # FL5444
Meets TDI Windstorm Requirements
Landmark PRO*
(and AR)
250 / 270 lb **
13 1/4" x 38 3/4"
66
5 5/8"
&
Landmark Premium
(and AR)
300 Ib
13 1/4" x 38 3/4''
66
5 5/8"
EcER/En
CITY OF -11,:iWILA
SEP 12 2019
PERMIT CENTER
Technical Data Sheet(Continued)
Landmark Series Shingles Page 2 of 3
INSTALLATION
The following is a general summary of the installation methods. Detailed installation instructions are
supplied oneach bundle ofLandmark shingles and must be followed. Separate appUcaUpnsheets may
also boobtained from CedainTmed.
Roof Deck Requirements: Apply shingles to minimum 3/8"Uhick plywood,minimum 7/16" thick non -
veneer (a.0.OGB).ornnhlimum1"0hick (nuomina0wood decks. The plywood ornon-veneer decks must
comply with the specifications of APA-The Engineered Wood Association.
Ventilation: Provisions for ventilation should meet or exceed current HUD Standards. To ensure
adequate balance ventilation, use a combination of continuous ridge ventilation (using CertainTeed Ridge
Vent products, or a comparable product with an external baffle) combined with soffit venting.
Valleys: Valley liner must be applied before shingles. The Closed -Cut valley application method is
recommended, using CertainTeed WinterGuard Waterproofing Shingle Underlayment or its equivalentto
line the valley prior to being fully covered by the shingles.
On slopes 4" per foot or greater, CertainTeed recommends one layer of DiamondDeckO or RoofRunnerT11
Synthetic Underlayment, or Roofers' SelectO High -Performance shingle underlayment, or shingle
underlayment meeting ASTM D226, D4869 or ASTM D6757. Always ensure sufficient deck ventilation,
and take particular care when DiamondOenk. RnofRunnmr, mrother synthetic undedmymoni is installed.
For UL fire rating, underlayment may be required. Corrosion -resistant drip edge is recommended and
should be placed over the underlayment at the rake and beneath the underlayment at the eaves. Follow
manufacturer's application instructions.
On low slopes (2" up to 4" per foot), apply one layer of nTaed WinterGuard Waterproofing Shingle
Underlayment (or equivalent meeting ASTM D1 970) over the entire roof deck. Or, in areas not prone to
snow or ice apply two layers of 36" wide felt shingle underlayment lapped 19", or two layers of
CertainTeed's DiamondDeck, RoofRunner or other synthetic underlayment per the manufacturer's low
slope application instructions. Shingle underlayment should meet ASTM D6757, ASTM D4869 or ASTM
D226. Ensure sufficient deck ventilation when these types of underlayments are installed. Specific and
more detailed installation instructions can be found on product packaging and in the CertainTeed Shingle
Applicator's Manual.
Fastening (NmilTrmk):
Low & Standard Slopes: Onlow and standard slopes, four nails are required per shingle. There are
three nail lines onNmOrokshingles. Position nails vertically between the upper and lower nailing -guide
lines. |timacceptable hmnail between either the middle and lower lines, orbetween the upper and middle
lines. Nails must be of sufficient length to penetrate into the deck 3/4" or through the thickness of the
decking, whichever ioless. They are tobalocated 1^and 12^infrom each side ofthe shingle (see
instructions on product wraps). Nails are toba 11 or 12 Qauge, corrosion -resistant roofing nails with 3/8"
heads.
Steep Slopes: Omslopes greater than 21^per foot, fasten each shingle with six nails and four spots of
roofing cement placed under each shingle according to application instructions provided on the shingle
package. Fasteners must penetrate the two -layer common bond area that is indicated by the middle and
lower Nmi|Trahlines, also illustrated onthe shingle package.
Technical Data Sheet (Cmntinumd)
Landmark Series Shingles Page 3 of 3
Application: The recommended application method is the'Five-Course.Diagonal Method'foundqneach
bundle ofmhingle� �.|n(hmethod.shin0|ocpuroeofset '' onwG"ond11|notrucionsa|oommybw
obtained from CertainTeed. These shingles may be used for new construction or for reroofing over
existing Metric -sized shingles.
Flashing: Use metal flashing.
Hips and Ridges, For capping hip and ridge apply CertainTeedGhadow Ridgea, Cedar Crestonr
Mountain Ridge' shingles of a like color.
MAINTENANCE
These shingles do not require maintenance when installed according to manufacturer's application
instructions. However, to protect the investment, any roof should be routinely inspected at least once a
year. Older roofs should belooked mtmore frequently.
WARRANTY
Landmark Premium (and AF).Landmark PRO/Architect 80AR, Landmark PRO (and AR).and Landmark
(and AR) shingles carry a lifetime limited, transferable warranty to the consumer against manufacturing
defects. In addition, Landmark Premium (and AR), Landmark Pnammium/An:hibect8G. Landmark PRO
(and AR), and Landmark (and AR) carry 1 0-years of SureStart"m Protection. For specific warranty details
and |imitatonm, refer hzthe warranty itself (available from the local supplier, roofing contractor o,on-line at
xmwm/.certointeed.uom).
FOR MORE INFORMATION
Sales Support Group: 800'233-8990
Web site: xmmw.cmrtaintmed.com
See us at our on-line specification writing tool, CertaSpec@, at www.certainteed.com/certaspec,
CmrtainTeed Roofing
2UMoores Road
Malvern, PA1S3S5
0 Copyright Certo|nTemdCorporation, 2018
All rights reserved. Updated: 11/2O18
CertainTee-d
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D19-0296 DATE: 09/12/19
PROJECT NAME: SUNRISE GARDEN SUITES - BLDG J
SITE ADDRESS: 14800 INTERURBAN AVE S
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
tVv°1\14
Structural
Planning Division
Permit Coordinator III
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 09/17/19
Structural Review Required
REVIEWER'S NITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews
Approved with Conditions
Denied
(ie: Zoning Issues
DUE DATE: 10/15/19
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections; Bldg E Fire EJ Ping PW Staff initials:
12/18/2013
Hoine Espanol Contact
Safety & Health Claims & Insurance
Washington State Department of
)Labor
& industries
Search LAI
A-7 Index Help N1y
Workplace Rights Trades & Licensing
TAVI'S ROOFING SERVICE LLC
Owner or tradesperson
Principals
MERCADO-LOPEZ,
GUSTAVO, PARTNER/MEMBER
Doing business as
TAVI'S ROOFING SERVICE LLC
WA UBI No.
604 048 545
30542 4TH AVE SW
FEDERAL WAY, WA 98023
253-217-0944
KING County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active
Meets current requirements.
License specialties
GENERAL
License no.
TAVISRS844QN
Effective — expiration
11/15/2016— 11/15/2020
Bond
Wesco Insurance Co
Bond account no.
46WB065508
$12,000.00
Received by L&I Effective date
11/15/2016 11/15/2016
Expiration date
Until Canceled
Insurance
Clear Blue Specialty INS
Policy no.
AR01-RS-1900561-00
$1,000,000.00
Received by L&I Effective date
07/03/2019 07/06/2019
Expiration date
07/06/2020
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Help us improve