Loading...
HomeMy WebLinkAboutPermit D19-0309 - KING COUNTY HOUSING AUTHORITY - TENANT IMPROVEMENT (MISSING PLANS)KING COUNTY HOUSING AUTHORITY 600 ANDOVER PARK W FINALED 05/14/2020 DI 9-0309 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049123 Permit Number: D19-0309 600 ANDOVER PARK W Project Name: KING COUNTY HOUSING AUTHORITY Issue Date: 11/22/2019 Permit Expires On: 5/20/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 MICHAEL CUADRA 700 ANDOVER PARK W SUITE C, TUKWILA, WA, 98188 REGENCY NW CONSTRUCTION INC PO BOX 6429 , BELLEVUE, WA, 98008 REGENNC041J5 KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK W - SUITE C, TUKWILA, WA, 98188 Phone: (206) 574-1219 Phone: (425) 883-1301 Expiration Date: 3/2/2020 DESCRIPTION OF WORK: INTERIOR RENOVATION OF OFFICE SPACE. INCLUDES DEMOLITION OF NON -LOAD BEARING INTERIOR PARTITIONS FOR NEW ENCLOSED OFFICES, RENOVATED OPEN WORK AREAS, STORAGE ROOMS, ETC. REDESIGN OF EXISTING BREAK ROOM, AND REPLACEMENT OF EXISTING FINISHES. THE EXISTING MECHANICAL, LIGHTING, POWER, DATA, AND LOW VOLTAGE SYSTEM WILL BE UPDATED. Project Valuation: $345,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $6,444.89 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: [hanne|izadon/6riping: CurbCutA\oess/Sidewa|k: Fire Loop Hydrant: Flood Control Zone: Hau|ino/OveoioeLoad: Land Altering: Volumes: Cut: O Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: O Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: �/// —,L� / I hearby certify that I have read and examined this permit and know the same to be true and correct, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not, The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and agree tothe conditions attached tothis permit. �/ ' /> Signature: � [\�_�� -L+u— Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance,or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number offire extinguishers required for alight hazard occupancy with Class Afire hazards is calculated at one extinguisher for each 3,000 sq, ft. of area. The extinguisher(s) should be of the "all purpcse" (ZA, 10 B:[) dry chemical type. The travel distance toany extinguisher must be 75' or less. (|F[ 9063)(NFPA10'5.4) l: Portable fire extinguishers, not housed in cabinets, shalt be installed on the hangers or bracketssupplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having agross weight not exceeding 4O pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top isnot more than 3.Sfeet (1067mm)above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IF[9O57and |F[ 906.9) J: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of 3: Fire extinguishers require monthly and yearly inspections. They must have atag urlabel securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall beemptied and subjected tothe applicable recharge procedures. |[ the required monthly and yearly inspections ofthe fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall bereadily openab|efrom the egress side without the use ofakey orspecial knowledge or effort. (|FC1Ol0.1.9) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle isengaged from inside the tenant space. (|FCChapter 1O) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (|FCChapter 1O) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist tooperate. (|FC1DlO.1.91) 10: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever |sless, from the nearest visible exit sign. (|FC10131) 11: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes ofthe letters not less than 0J5 inch (19.1mm)wide. The word "EX|T"shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not beless than 0.375inch (9.5mm). Signs larger than the minimum established in the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means isurisnot energized. |fanarrow isprovided aspart ofthe exit sign, the construction shall besuch that the arrow direction cannot bereadily changed. (|F[1813.61) lZ: Exit signs shall beilluminated atall times. Toensure continued illumination for aduration nfnot less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment o/on-site generator. (|F[ 1013.6.3) 13: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11lux) and a minimum atany point ofO.Ifoot-candle (1lux) measured along the path of egress atfloor level, Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (|F[IOO8.lS) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications tosprinkler systems involving more than 50heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior tosubmittal tothe Tukwila Fire Prevention Bureau. Nnsprinkler work shall commence without approved drawings. (City Ordinance No. Z4JG). 15: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA13-8.6.S33) 17: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall bedone inaccordance with applicable standards. (|F[9O1.4) 18: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A.73and City Ordinance #2437. 19: All new fire alarm systems or modifications to existing systerns shall have the written approval of The Tukwila Fire Prevention Bureau. Nowork shall commence until afire department permit has been obtained. (City Ordinance #l4]7)(|F[9Ol2) ^*VN —�� 4� 20: Anapproved manual �rea/a,msystem including audible/visual devices and manual pull stations isrequired for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (iBI.),N�.P.A.72and the City ofTukwila Ordinance #Z437. 21: Maintain fire alarm system oudib|e/vsua|ncti8cadun. Addition/relocation ofwalls orpartitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: All electrical work and equipment shall conform strictly Vnthe standards of the National Electrical Code. (NFPA7U) 24: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth inTable No. 8O3.1lof the International Building Code. 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #Z4J7) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ofsuch condition orviolation. 26: These plans were reviewed byInspector S11. |fyou have any questions, please call Tukwila Fire Prevention Bureau at(2O6)S75'44U7. 27: ***BU|LD|NGPERMIT COND|T|ONS' 28: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 29: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 30: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. AS[E7'Chapter ll 31: Partition walls shall not betied toasuspended ceiling grid. All partitions greater than 6feet inheight shall belaterally braced tothe building structure. Such bracing shall beindependent ofany ceiling splay bracing. 32: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code, 33: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 34: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement, 35: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ufTukwila Building Department(2O6-43l'3G7O). 36: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 37: VALIDITY OFPERMIT: The issuance orgranting ofapennit shall not beconstrued tobeapermit for, oran approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 38: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (2O6/431'367O). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)43Q'ga5O 1700 BUKD|NGF|NAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. b\CA Project No. 09 Date Application Accepted: tct Date Application Expires: ac-1. (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail. **Please Print** SITE INFORMATION King Co Assessor's Tax No.: J..Q 2. 361- 2.3 Site Address: 600 Andover Park West, Tukwila, WA 98188 Tenant Name: King County Housing Authority PROPERTY OWNER Name: King County Housing Authority Address: 700 Andover Park West City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Michael Cuadra Address: 700 Andover Park West, Suite C City: Tukwila State: WA Zip: 98188 Phone: (206) 574-1219 Email: MichaelC@kcha.org DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE Name: Greg Belding Address: 275 Fifth Street, Suite 100 City: Bremerton State: WA Zip: 98337 Phone: (360) 377-8773 Email: gbelding@rfmarch.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Si Contr Reg No.: Exp Date: Tukwila Business License No.: Suite Number: New Tenant: Floor: 1st .Yes E]..No ARCHITECT OF RECORD Company Name: Rice Fergus Miller, Inc. Address: 275 Fifth Street, Suite 100 City: Bremerton State: WA Zip: 98337 Phone: (360) 377-8773 Email: gbelding@rfmarch.com ENGINEER OF RECORD ---. Company Name: (See page 2 below.) Address: City: State: Zip: Phone: Email: LENDER — WHO IS FUNDING THE PROJECT (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: MONTHLY SERVICE BILLING -or- WATER METER REFUND/BILLING Name: , Address: City: State: Zip: Phone: WAPermit Center (RachellepiApplications\ WorMConstruction Permit Application Revised Revised: lime 2019 Page 1 of 3 BUILDING DIVISION INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 3 dfn Existing Building Valuation: $ 4) 700)000, Describe the scope of work (please provide detailed information): Interior renovation of office space. Project scope includes demolition of non -load bearing interior partitions for new enclosed offices, renovated open work areas, storage rooms, etc. Redesign of existing break room, and replacement of existing finishes. The existing mechanical, lighting, power, data and low voltage system will be updated. Will there be new rack storage? LJ.. Yes D., No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 10,150 sf 5,131 st N/A NIA V-B B 2nd Floor 9,100 sf N /A N /A N/A NIA N /A 3"1 Floor Floors Basement Accessory Structure* Garage 0 Attached 0 Detached Carport 0 Attached • Detached Covered Deck Uncovered Deck PLANNING DIVISION INFORMATION — 206-431-3670 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes Compact: Handicap: 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS — 206-575-4407 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 ...„..Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. PUBLIC WORKS INFORMATION — 206-433-0179 0 ...Permanent Water Meter Size (1). " WO # (2) " WO # (3) " WO # 0 ...Temporary Water Meter Size (1). " WO # (2) " WO # (3) " WO # 0 ...Water Only Meter Size " WO # 0 ....„-Deduct Water Meter Size , 1 0 „ .Sewer Main Extension Public 0 Private 0 0 ...Water Main Extension Public 0 Private El W\Permit Center (Rachelle)\Applications\ Word\ Construction Permit Application Revised 6-2019.docx Revised: June 2019 Page 2 of 3 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OAR" AuU-TUORIZED AGENT: Signature: 1 c.J2 C3C Q Date: Print Name: 1 tC A tL J L IZQ Mailing Address: I1ICdt AID--Q€ O 4 ENGINEER OF RECORD - MECHANICAL ENGINEERING Company Name: Ecotope, Inc. Address: 1917 1st Avenue, Suite 300 City: Seattle State: WA Zip: 98101 Phone: (206) 596-4703 Email: shawn@ecotope.com ENGINEER OF RECORD - ELECTRICAL ENGINEERING Company Name: BCE Engineers, Inc. Address: 6021 12th Street East, Suite 200 City: Fife State: WA Zip: 98424 Phone: (253)922-0446 Email: chuck.heaton@bceengineers.com Day Telephone26 % 514 r (2/ IC.A WA- 9F/86 City State Zip W:1Permit Center (Rachelle)\Applications\Word\Construction Permit Application Revised 6-2019.docx Revised: June 2019 Page 3 of 3 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID ,•=PermitTRA , T7, 7. $103.00 9-03 '!ANDOVER,P 2623049123 7,777,.7771.,777,7 77-.77,7,7777,77,, ,•77-77_,,,,,,,777,17,0p„.7,7.47,7„77.77,0,7, 77, , _ - Credit Card Fee • $3 00 Credit Card Fee R000.369.908.00.00 0.00 3.00 SPRINKLER COVER 04/06/2020 AND 100.00. SPRINKLER COVER 04/06/2020 AAJO R000.342.400.02.00 0.00 $100.00 TOTAL FEES PAID BY RECEIPT: R20709 $103.00 Date Paid: Friday, May 08, 2020 Paid By: MICHAEL CUADRA Pay Method: CREDIT CARD 002162 Printed: Friday, May 08, 2020 3:35 PM 1 of 1 CRWSYSTEMS 5/8/202V CO TUKNILA ETRAKZT 6200 SVUT*[ENTsn PLvo TUKWIL4, WA 98188 206-433-1870 CITY OF TVKWILx 0017340000802374464500 Date: 85/08/2020 03Bs:02 PM VISA CARD NUMBER: CREDIT CARD SALE *****+**** TOTAL AMOUNT: $103'80 APPROVAL [u: 002162 RECORD #: 000 cLsnn ID: slisa I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy 1/u DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $3,990.51 D19-0309 Address: 600 ANDOVER PARK W Apn: 2623049123 $3,990.51 Credit Card Fee $116.23 Credit Card Fee R000.369.908.00.00 0.00 $116.23 DEVELOPMENT $3,690.98 PERMIT FEE R000.322.100.00.00 0.00 $3,665.98 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $25,00 TECHNOLOGY FEE $183.30 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19141 R000.322.900.04.00 0.00 $183.30 $3,990.51 Date Paid: Friday, November 22, 2019 Paid By: MICHAEL CUADRA Pay Method: CREDIT CARD 090369 Printed: Friday, November 22, 2019 1:23 PM 1 of 1 Y TE S CO TUKWILA ETRxKIT 6200 SVUTHCENTER 8LVD TUKwILA, WA 98188 286'433'1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/22/2019 01:23:05 PM CREDIT CARD SALE VISA CARD NUMBER: ******* TKAm AMOUNT: $3'990.51 APPROVAL O}: 090369 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT Thank youl Merchant Copy Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $2,585.88 D19-0309 Address: 600 ANDOVER PARK W Apn: 2623049123 $2,454.38 Credit Card Fee $71.49 Credit Card Fee I R000.369.908.00.00 I 0.00 $71.49 DEVELOPMENT $2,382.89 PLAN CHECK FEE I R000,345.830.00.00 I 0.00 $2,382.89 M19-0162 Address: 600 ANDOVER PARK W Apn: 2623049123 $131.50 Credit Card Fee $3.83 Credit Card Fee R000.369,908.00.00 I 0.00 $3.83 MECHANICAL $ 27.67 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R18663 R000.322.102.00.00 0.00 $127.67 $2,585.88 Date Paid: Wednesday, September 25, 2019 Paid By: MICHAEL CUADRA Pay Method: CREDIT CARD 063224 Printed: Wednesday, September 25, 2019 9:34 1 of 1 AM CRWYSTEMS 0 0TUKWILxETRAKIT 6200 5VUTMCENTEK BLVD TUKWILA' WA 98188 206'433'1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/25/2019 VISA CARD NUMBER: TaAN AMOUNT: APPROVAL Co: RECORD #: CLERK ID: X 09:34:27 *n CREDIT CARD SALE ******** $2,585.88 063224 000 kandace {CARDHOLDER'S SzGmxTUns} I xGuss TO pw/ THE AaVvs TOTAL 4mOVmr ACCORDING TO THE CARD 155VER AGREEMENT (MERCHANT AGREEMENT IF [xsozT VOUCHER) Thank you! Merchant Copy Lighting Summary LTG -SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includingR2, R3, R4 ove 3 stories and all R1 Revised Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: King County Housing Authority 600 Building Date 9/13/2019 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department FnEL Use Company Name: BCE Engineers Inc. Company Address: 6021 12th St. E. Fife, WA 98424 Applicant Name: Jason Bordash Applicant Phone: 253-922-0446 Applicant Email: Jason.Bordash@BCEEngineers.com Project Description Ell New Building [1] Add ion REVIEMDFOR E No Lighting Scope Include PROJ-SUM form (included r COPEGOMfti • (8! ' g compliance forms. Interior Lighting System Description 2 Interior Lighting Plans Included Pendant lighting with daylight/o cupanc FARINEPlightin rider this project. NOV 14 2019 City of Tukwila BUILDING DIVISION Interiorightmg Power Allowance Method L1 Building Area Method rj Space -by -space Method Select method used in project. Interior Lighting Controls tjj1 All C405.2.1 - C405.2.8 Lighting Controls C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) • Additional Efficiency Package Option C406.4 Enhanced Digital Lighting Controls To comply with C406..4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: ® No Dwelling 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units 0 C406.3 High Efficacy Lighting . 0 R404.1 Residential High Efficacy Lighting, Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Description 2 Exterior Lighting Plans Included Recessed LED lightign for code required egress Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project 1] El Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance 0 111 Addition is combined with existing: For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. bt 9 - 0309 RECEIVED CITY OFTUIWILA NOV 0 4 2019 PERMIT CENTER Lighting Summary, cont. LTG -SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: King County Housing Authority 600 Building Date 9/13/2019 Change of Space Use mi Identify LTG-INT-BLD Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in or LTG-INT-SPACE form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. Na changes are being made to the inferior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced ❑ ❑ Less than 50% of existing are replaced ❑ ❑ Lamp and/or ballast replacement only — existing total wattage not increased ❑ ❑ ❑ 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form, 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) 121 ❑ ❑ New or moved lighting panel ❑ ❑ ❑ Interior space is reconfigured - luminaires unchanged or relocated only ❑ New wiring or circuit - For interior light ng, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted. for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. interior Lighting - Space -By -Space Method LTG-INT-SPACE Revised Nov 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Project Title: King County Housing Authority 600 Building Date 9/13/2019 Calculation Area NOTE 9 0 New Construction o Addition - O Addition stand alone + existing O Spaces where < 50% of O Spaces where z 50% of O Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) For Building Department Use LPA Calculation Type ® Standard 0 Additional Efficiency Package Option C406.3 Reduced Interior Lighting Power To comply with C406,3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting Wattage NOTE 1 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) E22.01 Office: Open plan 2231 0. 780 1790 E22.01 Office: Enclosed 1609 0. 890 1432 E22.01 Lounge/breakroom: all other 245 0. 580 192 E22,01 Storage room 166 0 . 500 83 E22,01 Copy/print room 86 0.580 50 Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 81--1 Total Area Retail Display 4337 LTG-INT-DISPLAY Allowed Watts Allowance from 3448 Proposed Lighting Wattage NUIt Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE Watts Proposed E22.01 Fixture Type: RL1 85 32 2720 E22.01 c Fixture Type: RL1E 11 0. 32 352 E22.01 Fixture Type: RL2 6 14 84 Proposed Retail Disp ay Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 3156 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included), For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/ineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG-iNT-DISPLAY form only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided in the Maximum Allowed Lighting Wattage table. d. If lighting alteration project includes some building areas or spaces where < 50% of luminaires are replaced, and other areas or spaces where 50% of luminaires are replaced, then these areas or spaces may be documented separately. If multiple forms will be completed to demonstrate compliance for the total scope of the alteration project, describe scope covered in form in User Note section. Interior Display Lighting - Space -by -Space LTG-INT-DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: King County Housing Authority 600 Building Date 9/13/2019 General Note - In Sales areas, an increase in lighting power allowance is permitted for lighting installed specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible merchandise display lighting may be included in the Gross Interior Area under each Retail category. This lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to general area lighting. Maximum Allowed Retail Display Lighting Wattage For Building Department Use User Note Location (plan #, room #) Retail Sales Area Type NOTE 1 Gross Interior Area in ft2 Allowed Watts per 2 NOTE 2 Watts Allowed (watts/ft2 x area) NOTE 3 Total Retail With Display Area Maximum Total Watts Base Allowance Allowance NOTE 4 Retail Display Lighting Retail Display Proposed Retail Display Lighting Wattage "T" Retail Area Location (plan #, room #) Fixture Description NOTES Number of Fixtures Watts per Fixture NOTE 7 Watts Proposed Proposed Retail Display Lighting Totals from LTG-INT-DISPLAY Total Retail Proposed Display Watts NOTE 8 Retail Display Power Allowance NOTE 9 Retail 1 Retail 2 Retail 3 Retail 4 Note 1 - Select retail sales areas from drop down menu. Only retail sales areas that comply with C405.4.2.2,1 may be entered in this table. Note 2 - Retail display lighting power allowances per C405.4.2.2.1, Equation 4-11. Note 3 - Unlit Message - Enter lighting fixture information for this retail sales area in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 4 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11. Note 5 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in this table. Note 6 - For proposed Fixture Description, list ALL proposed display lighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaries with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG-INT-SPACE. Note 9 - Retail display lighting power allowance is the lesser of the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in LTG-INT-SPACE. Note 10 - Enter a unique title for each lobby area in the project that has seperately controlled art/exhibit display lighting, A lobby area title (Column A) and the gross interior sf of the lobby area are are both required to generate the maximum display allowance, Note 11 - Lobby art and exhibit display wattage allowance per Table C405.4.2(2), Footnote c = 0.5 W/ft2. Note 12 - Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table. Note 13 - Only .separately controlled display fixtures installed in lobbies for the purpose of highlighting art and exhibits, that are independent of general area lighting, may be entered in this table. Note 14 - Lobby Art/Exhibit Display Allowance is automatically entered in LTG-INT-SPACE. Interior Display Lighting - Space -by -Space LTG-INT-DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: King County Housing Authority 600 Building Date 9/13/2019 General Note - In Lobby areas, an additional wattage allowance is permitted for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display lighting may use this additional allowance. Proposed display lighting for each Lobby area may not exceed this allowance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area NOTE 10 Lobby Description including (plan # & room #) Gross Interior Area in ft2 Maximum Display Watts Allowed Per Area NOTE 1 1 Proposed Display Lighting Total Per Area NOTE 12 Total Lobby with Display Area Total Lobby Art/Exhibit Display Allowance NOTE 14 Proposed Lobby Art/Exhibit Display Lighting Wattage NOTE" Lobby Area Location (plan #, room #) Fixture Description NOTE 6 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed TotalTotat Lobby ArUExhibit Proposed Display Watts nterior Lighting Power Allowance * See footnotes on previous page Interior Lighting - Building Area Method LTG-INT-BLD 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all RRevised Nov 2017 Project Title: King County Housing Authority 600 Building Date 9/13/2019 Calculation Area NOTE!f 0 New Construction n Addition - n Addition ''-'" stand alone '-''' + existing n Spaces where < 50% of Spaces where 50% of Spaces where the Use \-/ luminaires are replaced luminaires are replaced is changing (C505) For Building Department Use LPA Calculation Type ® Standard n Additional Efficiency Package Option 0 N'-' C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting WattageNOTE 1 Building Area Location (plan #, room #, or ALL) Area Description Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) NOTE 2 Total Proposed Lighting Wattage Building Area Location (plan #, room #) NOTE 3, 4, 5, 6 Fixture Description Number of Fixtures Watts per NOTE 7 Fixture Watts Proposed Compliance by Building Area "'" Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the project scope. Select building area category from drop down menu. Note 2 - Unlit Message - Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 3 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information, Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures .shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures, Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. Totals •, mow 9 - alcula ti on Area uerans: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Building Area types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, use LTG-INT-SPACE form to document compliance. Exterior Lighting LTG-EXT 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2 Project Title: King County Housing Authority 600 Building Date 9/13/2019 Exterior Lighting Zone O Zone 1 0 Zone 2 01)1 Zone 3 0 Zone 4 Exterior Lighting Zone selection required to enable LTG-EXT form. Zones are defined in Table C405.5.2(1) and specified by the jurisdiction. For Building Department Use Calculation Area 0 New construction O Addition - stand alone Q Addition + existing O Alteration with < 50% Alteration with 4 50% ext. ext. wattage replaced wattage replaced User Note Building Grounds Applies to individual luminaires > 100 Watts ❑ Efficacy > 80 lumens/watt ❑ Exemption ❑ Controlled by motion sensor Tradable Maximum Allowed Lighting Wattage NOTE 1 Base Site Allowance: 750 Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of items Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x If) NOTE 2 Total Allowed Tradable + Site Allowance Watts: 750 raaaal!e rropose ghting Wattage Tradable Surface Fixture Description NOTE 4, s Number of Fixtures Watts per Fixture NOTE s Watts Proposed Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: watts plus the base site allowance. Anv base site allowance not needed to make tradable watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage "'° 1 Site Allowance Remaining: 750 Non -Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of items Allowed Watts per ft2, If or item Allowed Watts x ft2 (or x If) NOTE 2 on -'tradable Proposed Lighting Wattage ""'t'• Non -Tradable Surface Fixture Description NOTE 4, 5 Number of Fixtures Watts per Fixture NOTE s Watts Proposed Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Non -Tradable Watts Exceeding LPA: 0 Remaining Site Allowance: 750 Exterior Lighting Note 1- List all exterior surfaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop down menu. Note 2 - Unlit Message - Enter lighting fixture information for this surface in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 3 - List all proposed lighting fixtures including existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type (if applicable). Note 5 - Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage tables in the same manner as new fixtures. Identify as existing in fixture description. Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. Note 7 - Automated Teller and Night Depositories - For each location, enter the number of ATM machines or depositories within that location. If there are multiple locations in the project, enter each location individually in the Non -Tradable Maximum Allowed Lighting Wattage table and identify the location in the Surface Description section. Lighting, Motor, and Electrical PermitChecklist, Pg. 1 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: King County Housing Authority 600 Building , Date 9/13/201 9 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405,2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans . for spaces and lighting zone(s) served, or exception taken E22.01 No C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters No C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specific application it serves E22.01 NA C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior light reduction controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls Yes C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor, time switch or digital timer switch) for all lighting zones; E22.01 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies E22,01 Yes C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; E22.01 Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception E22.01 NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. C405.2.6 Digital timer switch Indicate digital timer switch control includes: manual on/off, time delay, audible and visual indication of impending time-out Yes C405.2.4.2 C405,2,4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; E22.01 Indicate toplight daylight zone areas on plans, include sq. ft.; E22.01 For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) E22.01 Yes C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; E22.01 Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; E22.01 Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; E22,01 Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone E22,01 NA C405.2.5 Additional controls - Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section NA C405,2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method • • , Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: King County Housing Authority 600 Building Date 9/13/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting NA C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; E22.01 Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq, ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control —' -- - NA 1/1 C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; _ _ _ For all other exterior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5,2 NA C405.2.5 (listed after C405.2,7) Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS NA C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Lighting, Motor, and Electrical Permit CheCklist, Pg. 3 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: King County Housing Authority 600 Building Date 9/13/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Dope ment Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405,4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; E01.00 Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per side) E22.01 ' NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Interior Lighting Power Calculation - Indicate compliance path taken No C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area; identify locations of building areas on plans Yes C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage; identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance fortis that total connected interior lighting wattage is 25% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in interior fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option) EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG 1CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 King County Housing Authority 600 Building Date 9/13/2019 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING ALTERATIONS NA C503.6 Interior and parking garage lighting fixture alterations Where a 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate compliance path (building area or space -by -space method); include all new and existing -to - remain luminaires in compliance form (LTG-INT-BLD or LTG- INT-SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path __..._. �. Where < 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate total existing lighting wattage in each -space prior to alteration; include all new and existing -to -remain luminaires in LTG-INT-SPACE form; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration NA C503.6 Exterior lighting fixture alterations Where z 50% of existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed maximum allowed Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration Yes C503.6 Interior lighting wiring alterations Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); daylight responsive (C405.2.4); specific application (C405.2.5); exit signs (C405.3) E22.01 NA C503.6 Exterior lighting wiring alterations Where new wiring is installed to serve new exterior luminaires and /or luminaires are relocated to new circuit; indicate exterior lighting controls are provided (C405.2.7) NA C503.6 Lighting panel alterations Where a new lighting panel is installed or an existing panel is moved (all new raceway and conductor wiring); indicate lighting controls are provided (as applicable) - same provisions as wiring alterations; time switch controls and manual light reduction controls (C405.2.2) Yes C503.6 Interior space reconfiguration Where interior space(s) is reconfigured (permanently installed walls or ceiling -height partitions); indicate lighting controls are provided (as applicable) - same provisions as lighting panel alterations NA C504.2 Lighting repairs Identify existing luminaires being upgraded with bulb and / or ballast replacement; indicate fixture alteration does not increase existing fixture wattage NA C505.1 Change of space use Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables C405.4.2(1) or (2) Indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in compliance form (LTG-INT-BLD or LTG-INT-SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Yes C405.10 Controlled receptacles Identify all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; E21.01 E21.01 Indicate on plans whether the method of automatic control for each controlled receptacle zone is by occupant sensor or programmable time -of -day control Lighting, 2015 Washington Motor, and Electrical Permit Checklist, Pg. 5 LTG-CHK State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 20 7 King County Housing Authority 600 Building Date 9 201 9 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability y s,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C405.6 Electrical transformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter NA C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied NA C405.9.1 ca Elevatorcabs For luminaires in each elevator cab, provide calculated average efficacy of combined ,fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; - Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum perrnitted when not in use . NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) NA . C408.3 Scope of electrical power and lighting systems commissioning Indicate that all electrical systems (receptacles, transformers, motors, vertical and horizontal transportation) for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; Where total building lighting load is > 20 kW, or where total hghting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting. control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception; NA C405.13 C408.1.1 C408.1.2 C408.1.4,2 C103.6 Commissioning requirements in construction documents Indicate Cx requirements in plans and specifications for all applicable electrical and lighting control systems per C408; Include general summary with at minimum Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project dose out documentation per C103.6, and conflict of interest plan (if required); Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1,4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final electrical inspection NA C408.3.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION NA C103.6.3 Project close out documentation requirements Indicate in plans that project close out documentation is required including WSEC lighting compliance forms and calculations that document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities If "no" is'selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist •-• City of Tukwila Department of Community Development October 23, 2019 MICHAEL CUADRA 700 ANDOVER PARK W - SUITE C TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D19-0309 KING COUNTY HOUSING AUTHORITY - 600 ANDOVER PARK W Dear MICHAEL CUADRA, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seaUstamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. In addition to the egress plan provided, show specific common paths of egress where Emergency illumination shall be provided an average 1 foot-candle and a minimum at any point of 0.1-foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required at exterior landings or exit discharge doorways where two or more exits are required. Egress paths shall be continuous, unobstructed, unbroken paths to each exit. Designated egress paths are those that shall be light meter inspected for egress illumination requirements. (IBC 107.2.3 & Section 1006) 2. Provide a completed 2015 Washington State Energy Code "LIGHTING SUMMARY" Compliance Form for Commercial Buildings, available online at: https://wseccompliancedocuments.com/index.php on the right side you will see the link "WSEC Documents". Click on that and if you haven't already, you will need to create an account. Sign into the account and there you will find the forms. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • In order to better expedite your resubmittal, a 'Revision Submittal Sheetmust accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No, Di9-0309 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 r\4ERM!T COOP.D COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0309 DATE: 11/06/2019 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter Revision # after Permit Issued DEPARTMENTS. Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator n • PRELIMINARY REVIEW: Not Applicable r (no approval/review required) DATE: 11/07/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 12/05/2019 Approved with Conditions ri Denied (ie: Zoning Issues n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corTections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 • 11 T COO ID COPY --- -. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0309 DATE: 09/30/2019 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: tx4 Building Division /PA W 11);Nui°1)1 Public Works Atq tottltilK Fire Prevention Structural LI vviS 104' Planning Division Permit Coordinator ri PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/01/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews n Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 10/29/2019 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 10 — Departments issued corrections: Bldg Fire 0 Ping D PW D Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date:11/1/19 Plan Check/Permit Number: D19-0309 El Response to Incomplete Letter # Response to Correction Letter # 1 Revision # after Permit is Issued Ej Revision requested by a City Building Inspector or Plans Examiner 1:1 Deferred Submittal # Project Name: King County Housing Authority Project Address: 600 Andover Park W Contact Person: Michael Cuadra Phone Number: (206) 719-1072 Summary of Revision: Item 1: Sheet A01.01 "Life Safety Plan — Level 1" is updated to show "common egress path". Also, added keynote #1 at areas outside of our project scope for contractor to verify existing illumination level and remedy as required so that the building is in compliance. Drawing sheet E22.01 is updated to meet minimum illumination level for egress path. Foot-candle calculations are included for review. Item2: See attached (2) copies of "Lighting Summary" Sheet Number(s): A01.01, E22.01 "Cloud" or highlight all areas of revision including e ofrevision Received at the City of Tukwila Permit Center by• E- Entered in TRAKiT on RECEIVED C TY OF TUKWILA NOV 0 4 2019 PERMIT CENTER R12017036 KCHA Projec02017036.20 KCHA 600 Bldg Interiors0- Agency \Building DeptTermit SeA_Comments\ 191028 Correction Leeter #1 - Response (Draft)\Revision Submittal Formi)19.0309.doe Revised: August 2015 Labor & Industries (https://lni.wa.gov) c :ractors REGENCY NW CONSTRUCTION INC Owner or tradesperson Principals FOOTE, BRIAN LEE, PRESIDENT Doing business as REGENCY NW CONSTRUCTION INC WA UBI No. 601 696 917 PO BOX 6429 BELLEVUE, WA 98008 425-883-1301 KING County Business type Corporation Governing persons BRIAN L FOOTE BRIAN FOOTE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. REGENNC041J5 Effective — expiration 04/25/1996— 03/02/2020 Bond North American Spec Ins Co Bond account no. 2281442 Received by L&I 01/24/2019 $12,000.00 Effective date 02/20/2019 Expiration date Until Canceled Ohio Cas Ins Co $12,000.00 Bond account no. 023031132 Received by L&I Effective date 01/12/2016 02/20/2016 Expiration date Until Canceled Bond history Insurance Underwriters at Lloyds $1,000,000.00 Policy no. WCISCGL000298801 Received by L&I Effective date 02/20/2019 02/20/2019 Expiration date 02/19/2020 Insurance history RICIPrgusuaiel KING COUNTY HOUSING AUTHORITY 600 BUILDING INTERIOR RENOVATION CAMPUS SITE PLAN (FOR REFERENCE ONLY) LINE=360.00' y w a 0 1 PROPERTY LINE=150.00' EXISTING PARKING LOT PROPERTY LINE=150.00' EXISTING DRIVEWAY EXISTING DRIVEWAY R co to r p Cr LU - PROPERTY LINE = 319.85' EXISTING KCHA CENTRAL OFFICE ANNEX (NOT IN SCOPE) EXISTING DRIVEWAY EXISTING PARKING LOT z N _ - - RAILROAD TRACK EXISTING LOADING DOCK = PROPERTY LINE = 269.8 PERMIT SET EXISTING DRIVEWAY INKLER BOULEVARD PturnbinV Gas Piping City of TLIKwiia LNG ©IVISIO PROJECT TEAM OWNER KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK WEST, SUITE C SEATTLE, WA 98188 DON HATFIELD (206) 574-1213 DONALDH@KCHA.ORG CONTRACTOR TBD ARCHITECT RICE FERGUS MILLER 275 5TH ST, SUITE 100 BREMERTON, WA 98337 GREGORY BELDING, ARCHITECT OF RECORD (360) 362-1429 GBELDING@RFMARCH.COM KIMBERLYN CAOAGAS (360) 362-1442 KCAOAGAS@RFMARCH.COM VICINITY MAP MECHANICAL ECOTOPE, INC. 1917 1ST AVE, SUITE 300 SEATTLE, WA 98101 SHAWN ORAM, PRINCIPAL (206) 596-4703 SHAWN@ECOTOPE.COM KATIE GLORE (206) 596-4728 KATIE@ECOTOPE.COM ELECTRICAL BCE ENGINEERS, INC. 6021 12TH STREET EAST, SUITE 200 FIFE, WA 98424 SCOTT ZIMBELMAN, PROJECT MANAGER (253) 922-0446 SCOTT.ZIMBELMAN@BCEENGINEERS.COM JASON BORDASH (253) 922-0446 JASON.BORDASH@BCEENGINEERS. COM I-5j TUKWILA POND PARK STRANDER BLVD, Yi a- wl w 0'I ,�10 �1 aT I,� I ¢ PROJECT SITE -1 MINKLER BLVD PROJECT INFORMATION PARCEL NUMBER 2623049123 LEGAL DESCRIPTION PAR A OF CITY OF TUKWILA BLA TO SP #77-14-SS SD BLA REC AF #7711230934 & DAF - POR NE 1/4 OF SE 1/4 & OF SE 1/4 OF NE 1/4 AS FOLG - BEG SW COR NE 1/4 OF SE 1/4 TH S 88-12-32 E 30 FT TO PT OF ORIGIN OF C/L OF P-17 DRAINAGE CHANNEL WCH CHANNEL CONTINUES S 88-12-32 E TO TERM AT WLY MGN CHRISTENSON RD TH CONTG S 88-12-32 E 360 FT TH N 1-47-28 E 69 FT TO NLY MGN OF MINKLER BLVD & TPOB TH CONTG N 1-47-28 E 967.57 FT TO SW COR ANDOVER INDUSTRIAL PARK NO 5 TH CONTG N 01.47-28 E 672.06 FT TH SWLY ALG CURVE TO RGT RAD 410.28 FT TH CENTER OF WCH BEARS N 88-12-32 W THRU C/A OF 82-57-39 ARC DIST 594.06 FT TO ELY MGN OF ANDOVER PARK WEST TH S 01-47-28 W 1182.44 FT TH ALG CURVE TO LFT RAD 50 FT THRU C/A OF 90-00-00 AN ARC DIST 78.54 FT TO NLY MGN OF MINKLER BLVD TH S 88-12-32 E 310 FT TO TPOB PROJECT TYPE TENANT IMPROVEMENT CONSTRUCTION TYPE III -A PROJECT SCOPE INTERIOR RENOVATION OF APPROXIMATELY 5,100 SF OF OFFICE SPACE ON THE FIRST FLOOR OF THE EXISTING OFFICE BUILDING. ARCHITECTURAL SCOPE TO INCLUDE: DEMOLITION OF SELECT NON --LOAD BEARING INTERIOR PARTITION WALLS FOR NEW ENCLOSED OFFICES, RENOVATED OPEN WORK AREAS, STORAGE ROOMS, AND COPIER/WORK SPACE; REDESIGN OF THE EXISTING BREAK ROOM; AND REPLACEMENT OF EXISTING FINISHES. THE EXISTING MECHANICAL SYSTEM, LIGHTING, POWER, DATA, AND LOW VOLTAGE SYSTEMS WILL ALSO BE UPDATED. DRAWING INDEX SHEET # ? SHEET NAME ARCHITECTURAL A00.01 COVER SHEET A00.02 GENERAL INFORMATION A01.01 LIFE SAFETY PLAN - LEVEL 1 D21.01 I DEMO FLOOR PLAN - LEVEL 1 D22.01 DEMO REFLECTED CEILING PLAN - LEVEL 1 A21.01 FLOOR PLAN - LEVEL 1 A22.01 IREFLECTED CEILING PLAN - LEVEL 1 REVISION A70.01 INTERIOR ELEVATIONS, FINISH SCHEDULE, & DOOR SCHEDULE A71.01 INTERIOR DETAILS A71.02 CASEWORK DETAILS MECHANICAL M00.01 GENERAL NOTES AND MECHANICAL SCHEDULE M11.01 MECHANICAL DEMO PLAN M21.01 ; MECHANICAL LEVEL 1 FLOOR PLAN - EXISTING M21,02 ; MECHANICAL LEVEL 1 FLOOR PLAN - NEW M22.01 I REFLECTED CEILING PLAN LEVEL 1 - NEW ELECTRICAL E01.00 ILEGEND, FIXTURE SCHEDULE ED21.01 I DEMO FLOOR PLAN - LEVEL 1- POWER ED22 01 DEMO REFLECTED CEILING PLAN - LEVEL 1- ELECTRICAL E21.01 I FLOOR PLAN - LEVEL 1- POWER E21.02 ;FLOOR PLAN - LEVEL 1- DATA E22.01LOOR PLAN - LEVEL 1- LIGHTING E06.00 PANEL SCHEDULES E06.01 METERING / LOAD CALC DAT NUMBER OF SHEETS: 23 ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM '7 17 /7 F- 0 0 I co 0 0 0 F- 0 z W 0 Ct W F- z V z 0 J CO 0 0 CSD - w ec Q 0 LLI L.L J 0 z Q CD CD F- PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE C- f• JtLn(NG C) COVER SHEET RE C 'LC),-` T SEP 2- 2 SHEET # 0.01 ANDOVER PARK WEST ABBREVIATIONS « F CONTINUED -- DRAWING LEGEND R�ergusiviL1 FR A AN AB ACC ACST ACT ADJ AFF ALT ALUM APPROX ARCH AUTO BATH BD BED BLDG BLKG BM BO BTWN BUR -C- CAB CALC CB CEM CF01 CG CH CIP CJ CL CLG CLO CLR CMU CO COL CONC CONF CONN CONSTR CONT CONTR COORD CORR CP CPT CRL CS CSMT CTR «D« D DBL DEB DEMO DEPT DET DF DIA DIM DISP DL DN DP DR DS DW DWG DWR .. E .. E EA EC EE El FS EF EJ EL ELEC ELEV EMER ENCL EP EQ EQUIP EST EW EWC EWH EXH EXIST EXP EXT F-- FA FAAP FD FDC FDTN FDV FE FEC FF FH FHC FHR FILM FIN FIXT FLASH FLR FLUOR FMF AMP AUDIO VISUAL ANCHOR BOLT ACCESSORIES ACOUSTIC(AL) ACOUSTIC CEILING TILE ADJACENT, ADJUST(ABLE) ABOVE FLOOR FINISH ALTERNATE ALUMINUM APPROXIMATELY ARCHITECT(URAL) AUTOMATIC BATHROOM BOARD BEDROOM BUILDING BLOCKING BEAM BOTTOM OF BETWEEN BUILT UP ROOF(ING) CABINET CALCULATION CATCH BASIN, CORNER BEAD CEMENT CONTRACTOR FURNISHED & OWNER INSTALLED CORNER GUARD COAT HOOK CAST IN PLACE CONTROL JOINT, CONSTRUCTION JOINT CENTERLINE CEILING CLOSET CLEAR CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONFERENCE CONNECT(ION) CONSTRUCTION CONTINUE, CONTINUOUS CONTRACTOR COORDINATE CORRIDOR CEMENT PLASTER CARPET CHAIR RAIL CONCRETE SEALER CASEMENT CENTER DEEP, DRYER DOUBLE DRY ERASE BOARD DEMOLISH(ED), DEMOLITION DEPARTMENT DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DISPOSAL DEAD LOAD DOWN DECORATIVE PANEL DOOR, DINING ROOM, DRAIN DOWNSPOUT DISHWASHER DRAWING DRAWER EAST EACH EDGE OF CURB EACH END EXTERIOR INSULATION & FINISH SYSTEM EACH FACE EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EMERGENCY ENCLOSE(D), ENCLOSURE ELECTRICAL PANELBOARD EQUAL EQUIPMENT ESTIMATE(D) EACH WAY ELECTRIC WATER COOLER ELECTRIC WATER HEATER EXHAUST EXISTING EXPOSED, EXPANSION EXTERIOR FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FLOOR DRAIN FIRE DEPARTMENT CONNECTION FOUNDATION FIRE DEPARTMENT VALVE FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FACTORY FINISH, FINISH FACE FIRE HYDRANT FIRE HOSE CABINET FIRE HOSE RACK, FIRE HOSE REEL SPECIALTY FILM FINISHED) FIXTURE FLASHING FLOOR FLUORESCENT FLEXIBLE MEMBRANE FLASHING FOB FOC FOF FOM FOS FPL FRP FRTW FRZ FS FT FTG FURN G- G GA GALV GAR GB GC GEN GFRG GI GL GLULAM GR GT GWB H -- H HB HC HDR HDW HGR HM HRL HORIZ HR HT HVAC HWT IIC IN INC INCL INFO INSTL INSUL INT JAN JBOX JT --K« KD KIT KW «L- L LAB LAM LAU LAV LB(S) LDG LINO LL LOC LPT LR LRG LT LTG LVR ..M.. M/S MACH MAINT MATL MAX MB MBR MC MDO MECH MED MEDS MEMB MF77 MFR MFRREC MGR MH MIN MIR MISC MO MTD MTL MULL MULT MW N NA NC NCAP NIC NO NOM NTS FACE OF BRICK FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FIREPLACE FIBER REINFORCED PLASTIC FIRE RETARDANT TREATED WOOD FREEZER FULL SIZE FOOT, FEET FOOTING FURNITURE GROUND GAUGE GALVANIZED GARAGE GRAB BAR GENERAL CONTRACTOR GENERAL GLASS REINFORCED PLASTER, GLASS FIBER REINFORCED GYPSUM GALVANIZED IRON GLASS, GLAZING GLUE LAMINATED GROSS GROUT GYPSUM WALL BOARD HIGH, HEIGHT HOSE BIB HOLLOW CORE HEADER HARDWARE HANGER HOLLOW METAL HANDRAIL HORIZONTAL HOURS HEIGHT HEATING. VENTILATION & AIR CONDITIONING HOT WATER TANK IMPACT INSULATION CLASS INCH(ES) INCREASE INCLUDE(D), INCLUDING INFORMATION INSTALL(ATION) INSULATION INTERIOR JANITOR JUNCTION BOX JOINT KILN DRIED KITCHEN KILOWATT LEFT, LINEN, LONG LABORATORY LAMINATE(D) LAUNDRY LAVATORY POUND(S) LANDING LINOLEUM LIVE LOAD LOCATION LOW POINT LIVING ROOM LARGE LIGHT LIGHTING LOUVER MIRROR & SHELF MACHINE MAINTENANCE MATERIAL MAXIMUM MACHINE BOLT MASTER BEDROOM MEDICINE CABINET MEDIUM DENSITY OVERLAY MECHANIC(AL) MEDIUM MEDICINE, MEDICAL MEMBRANE MEZZANINE MANUFACTURER MANUFACTURER'S RECOMMENDATION(S) MANAGER MANHOLE MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING, MONITOR MOUNTED METAL MULLION MULTIPLE MICROWAVE OVEN NORTH NOT APPLICABLE NOISE CRITERIA, NURSE CALL NURSE CALL ANNUNCIATOR PANEL NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE 0/ OA OC OCC OD OFCI OF01 OFD OFF OGL OH OPH OPNG OPP ORD OZ P PC PCC PED PERF PERM PERP PFP PIV PL PLAM PLAS PLBG PLYWD PMTL PNT PP PR PREFAB PRELIM PRKG PROP PS PSF PSI PT PTD PTN PVC PVD PVG PVR QTY QTZ --R-- R R/S RA RCP RD REBAR REC RECPT REF REINF RES REQD REST RET REV RF RH RM RO RP RS RT RVL ..S-- S SAN SC SCD SCHED SD SEAL SECT SEP SF SG SHR SHT SHTG SHLV SIM SM SND SOG SOL STO SPEC SPKLR SPKR SQ SQIN SS SST ST STA STC STD STL STOR STRUCT SU SUBFL SUSP SW SYM OVER OVERALL ON CENTER OCCUPANTS. OCCUPANT LOAD, OCCUPANCY OUTSIDE DIAMETER OWNER FURNISHED & CONTRACTOR INSTALLED OWNER FURNISHED & OWNER INSTALLED OVERFLOW DRAIN OFFICE OBSCURE GLASS OVERHEAD OPPOSITE HAND OPENING OPPOSITE OVERFLOW ROOF DRAIN OUNCE PAINT(ED), PANTRY PORTLAND CEMENT PRECAST CONCRETE PEDESTAL PERFORATED PERMANENT PERPENDICULAR PREPARED FOR PAINT POST INDICATOR VALVE PLATE, PROPERTY LINE PLASTIC LAMINATE PLASTER PLUMBING PLYWOOD PAINTED METAL POINT POWER POLE PAIR PREFABRICATE PRELIMINARY PARKING PROPERTY PROJECTOR SCREEN POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESERVATIVE TREATED, PRESSURE TREATED, POST TENSIONED PAPER TOWEL DISPENSER PARTITION POLYVINYL CHLORIDE, POLYVINYL CHLORIDE PIPE PROVIDE PAVING PAVERS QUANTITY QUARTZ RISER, RADIUS ROD & SHELF RETURN AIR REFLECTED CEILING PLAN ROOF DRAIN REINFORCING BAR RECESSED RECEPTACLE REFERENCE, REFRIGERATOR REINFORCE(D), REINFORCING RESILIENT REQUIRED RESTROOM RETAINING REVISED, REVISION RAISED FLOOR(ING) ROBE HOOK ROOM ROUGH OPENING RADIUS POINT ROUGH SAWN RIGHT REVEAL SOUTH, SINK SANITARY SOLID CORE SEAT COVER DISPENSER SCHEDULE SOAP DISH, SOAP DISPENSER, STORM DRAIN SEALER, SEALANT SECTION SEPARATION SQUARE FEET SAFETY GLASS, SAFETY GLAZING SHOWER SHEET SHEATHING, SHEETING SHELVING SIMILAR SHEET METAL SANITARY NAPKIN DISPOSAL SLAB ON GRADE SOLID SURFACE STONE SPECIFICATION(S) SPRINKLER SPEAKER SQUARE SQUARE INCH SERVICE SINK, SANITARY SEWER STAINLESS STEEL STREET, STAIN STATION SOUND TRANSMISSION CLASS STANDARD STEEL STORAGE STRUCTURAL SOILED UTILITY SUBFLOOR SUSPENDED SWITCH SYMMETRICAL T T&B T&G TB TEL TEMP TER THK TI TL TMPD TO TOE TOC TOF TOS TOW TPD TR TV TYP UC UGND UNO UP UTIL V.. V VCT VEH VEND VERT VEST VIF VNR VTO VTR W W/ W/D W/O WB WC WCO WD WF WH WIC WIN WM WO WP WPM WR WRB WSCT WRC WT WWF TREAD, TILE TOP AND BOTTOM TONGUE AND GROOVE TOWEL BAR TELEPHONE TEMPORARY, TEMPERATURE TERRAZZO THICK(NESS) TENANT IMPROVEMENT TOTAL LOAD TEMPERED TOP OF TOP OF BEAM TOP OF CURB, TOP OF CONCRETE TOP OF FOOTING, TOP OF FLOOR, TOP OF FRAME TOP OF SLAB, TOP OF STEEL TOP OF WALL TOILET PAPER DISPENSER TRANSITION STRIP TELEVISION TYPICAL UNDERCOUNTER, UNDERCABINET, UNDERCUT UNDERGROUND UNLESS NOTED OTHERWISE UTILITY POLE UTILITY VOLT(AGE) VINYL COMPOSITION TILE VEHICLE VENDING MACHINE VERTICAL VESTIBULE VERIFY IN FIELD VENEER VENT TO OUTSIDE VENT THROUGH ROOF WEST, WIDE, WASHING MACHINE WITH WASHER & DRYER WITHOUT WALL BASE WATER CLOSET, WALL COVERING WINDOW COVERING WOOD WIDE FLANGE WATER HEATER WALK-IN CLOSET WINDOW WIRE MOLD, WATER METER, WIRE MESH WALK -OFF FLOORING WORK POINT, WATERPROOFING, WEATHERPROOF WATERPROOF MEMBRANE WATER REPELLENT, WATER RESISTANT WATER RESISTANT BARRIER WAINSCOT WASTE RECEPTACLE WEIGHT WELDED WIRE FABRIC -- ASSOCIATIONS & CODES -- AISI AMCA ANSI APA APWA ARIB ASME ASTM AWI AWS AWWA CRSI CS CSI FGI FGMA GA HUD IBC ICC IEEE IFC IMC IRC IPCEA MLA NAAMM NEMA NWMA OSHA PS SDI SMACNA SSPC TCA UL UPC WAC WISHA WSDOH WSDSHS WSEC WSVIAQC WWPA AMERICAN IRON AND STEEL INSTITUTE AIR MOVING & CONDITIONING ASSOCIATION AMERICAN NATIONAL STANDARDS INSTITUTE AMERICAN PLYWOOD ASSOCIATION AMERICAN PUBLIC WORKS ASSOCIATION ASPHALT ROOFING INDUSTRY BUREAU AMERICAN SOCIETY OF MECHANICAL ENGINEERS AMERICAN SOCIETY FOR TESTING & MATERIALS AMERICAN WOODWORK INSTITUTE AMERICAN WELDING SOCIETY AMERICAN WATER WORKS ASSOCIATION CONCRETE REINFORCING STEEL INSTITUTE COMMERCIAL STANDARD OF THE US DEPARTMENT OF COMMERCE CONSTRUCTION SPECIFICATIONS INSTITUTE FACILITY GUIDELINES INSTITUTE FLAT GLASS MARKETING ASSOCIATION GYPSUM ASSOCIATION US DEPARTMENT OF HEALTH & URBAN DEVELOPMENT INTERNATIONAL BUILDING CODE INTERNATIONAL CODE COUNCIL INSTITUTE OF ELECTRICAL & ELECTRONIC ENGINEERS INTERNATIONAL FIRE CODE INTERNATIONAL MECHANICAL CODE INTERNATIONAL RESIDENTIAL CODE INSULATED POWER CABLE ENGINEER ASSOCIATION METAL LATH ASSOCIATION NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS NATIONAL FIRE PROTECTION ASSOCIATION NATIONAL WOODWORK MANUFACTURER'S ASSOCIATION OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION PRODUCT STANDARD OF US DEPARTMENT OF COMMERCE STEEL DECK INSTITUTE, STEEL DOOR INSTITUTE SHEET METAL & AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION STEEL STRUCTURES PAINTING COUNCIL TILE COUNCIL OF AMERICA UNDERWRITER'S LABORATORIES UNIFORM PLUMBING CODE WASHINGTON ADMINISTRATIVE CODE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT WASHINGTON STATE DEPARTMENT OF HEALTH WASHINGTON STATE DEPARTMENT OF SOCIAL & HEALTH SERVICES WASHINGTON STATE ENERGY CODE WASHINGTON STATE VENTILATION & INDOOR AIR QUALITY CODE WESTERN WOOD PRODUCTS ASSOCIATION --ANNOTATIONS-- PLAN NORTH - TRUE NORTH # / A##.## NORTH ARROW GRID LINE MATCH LINE LEVEL NAME ( ELEVATION DATUM ELEVATION ELEVATION --VIEW REFERENCE-- f bJ --TAGS-- X##X'. e C##> SPOT ELEVATION BREAK LINE REVISION CLOUD W/ TAG DRAWING ORGANIZATION BUILDING SECTION WALL SECTION, VERTICAL SHAFT! CHASE DETAIL SECTION EXTERIOR ELEVATION INTERIOR ELEVATION ENLARGED VIEW, DETAIL VIEW KEYNOTE WALL TAG DOOR TAG WINDOW TAG STOREFRONT TAG CURTAIN WALL TAG GLAZING TAG LIGHTING TAG FINISH TAG FURNITURE/ EQUIPMENT TAG SHEET LAYOUT 1. DETAIL NUMBERS MAY FOLLOW A NUMBERING SEQUENCE SIMILAR TO DIAGRAM BELOW. 2. DETAIL NUMBERS MAY SKIP WHEN A DETAIL FALLS WITHIN MULTIPLE CELLS. SHEET LAYOUT DIAGRAM --LINEWORK-- CONSTRUCTION LINE STYLES HATCH PATTERNS EXISTING ELEMENT TO REMAIN DEMOLISHED ELEMENT NEW CONSTRUCTION ELEMENT BATT INSULATION CENTERLINE CLEARANCES HIDDEN ELEMENT OPENING BEYOND OVERHEAD ELEMENT PROPERTY LINE OUT OF SCOPE LIMITED SCOPE CONCRETE EARTH BELOW GRADE GYPSUM BOARD MASONRY, BRICK (PLAN VIEW) MASONRY, CMU (PLAN VIEW) METAL RIGID INSULATION WOOD ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM •E LIT ARCNlttEC? z 1— O z V z 0 J CO W 0 ♦o OVER PARK WEST 00 CO 00 CT) J PROJECT # 2017036.20 ISSUE DATE SEPTEMBER 12, 20 9 REVISION SCHEDULE RE+E LANK, ;C1 GENERAL INFORMATION CITY 5 SEP -2 5 2 ..._. SHEET # A00.02 BUILDING CODE ANALYSIS ZONING INFORMATION JURISDICTION CITY OF TUKWILA, WASHINGTON EXISTING TOTAL SITE AREA 54,120 SF (1.24 ACRES) (NO CHANGE) NOTES & LEGEND - LIFE SAFETY PLAN ANNOTATION TAG EXITING RcgrergusamER ARCHITECTURE INTERIORS PLANNING VIZLAB BUILDING CODES 2015 INTERNATIONAL BUILDING CODE (IBC) WI WASHINGTON STATE AMENDMENTS, WAC 51-50 2015 INTERNATIONAL FIRE CODE (IFC) W/ WASHINGTON STATE AMENDMENTS, WAC 51-54 2015 INTERNATIONAL MECHANICAL CODE (IMC) WI WASHINGTON STATE AMENDMENTS. WAC 51-52 2015 UNIFORM PLUMBING CODE (UPC) W/ WASHINGTON STATE AMENDMENTS, WAC 51-56 & WAC 51-57 2015 WASHINGTON STATE ENERGY CODE, WAC 51-11 2015 NATIONAL ELECTRICAL CODE (NFPA 70) ACCESSIBILITY CODES 2015 IBC - CHAPTER 11 ICC/ANSI A117.1-2009 (REFERENCED BY IBC) CHAPTER 3: USE & OCCUPANCY CLASSIFICATION OCCUPANCY CLASSIFICATION: B - BUSINESS DESIGN NOTE: PER IBC SECTION 303.1.1, SPACES USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY. CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS DESIGN NOTE: NO CHANGE TO EXISTING BUILDING ENVELOPE TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE OCCUPANCY SPRINKLERED CONSTRUCTION TYPE HEIGHT SM (MULTI -STORY, NFPA 13) TYPE V-B 60 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE OCCUPANCY SPRINKLERED CONSTRUCTION TYPE STORIES B SM (MULTI -STORY, NFPA 13) TYPE V-B 3 EXISTING BUILDING AREA (NO CHANGE): LEVEL 1: 10,180 SF LEVEL 2: 9,100 SF TOTAL BUILDING AREA: 19,280 SF EXISTING BUILDING HEIGHT (NO CHANGE): NUMBER OF STORIES: 2 29'-0" FROM GRADE TO TOP OF PARAPET 26'-0" FROM GRADE TO TOP OF ROOF CHAPTER 6: TYPES OF CONSTRUCTION CONSTRUCTION TYPE: V-B TABLE 601 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) BUILDING ELEMENT TYPE V-B PRIMARY STRUCTURAL FRAME BEARING WALLS - EXTERIOR 0 BEARING WALLS - INTERIOR 0 NONBEARING WALLS AND PARTITIONS - EXTERIOR NONBEARING WALLS AND PARTITIONS - INTERIOR FLOOR CONSTRUCTION SEE TABLE 602 0 ROOF CONSTRUCTION DESIGN NOTE: NO CHANGES TO EXISTING BUILDING ELEMENTS PERMITTED SITE USE ZONE TUC - TUKWILA URBAN CENTER PERMITTED USE OFFICE (NO CHANGE) SPECIAL REGULATIONS N/A SETBACKS N/A PARKING REQUIREMENTS NO CHANGE IN BUILDING USE OR SIZE CHAPTER 10: MEANS OF EGRESS DESIGN NOTES: PER IBC SECTION/TABLE 1006.2.1 SECTION/TABLE 1006.3.1, THE PROVIDED EXISTING EXITS AND EXIT ACCESS DOORWAYS SATISFY THE REQUIRED TOTAL OF TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE. OCCUPANT LOAD CHART- LEVEL 1 IBC 2015 TABLE 1004.1.2 MAXIMUM FLOOR AREA , ROOM INFORMATION OCCUPANCY CLASSIFICATION ALLOWANCES PER LOAD FACTOR 100 SF 300 SF OCCUPANT GROSS/NET GROSS GROSS OCCUPANT LOAD 1 NUMBER NAME AREA FUNCTION OF SPACE G1oo WORK ROOM 85 SF B BUSINESS AREAS 1 101 1 FILE STORAGE 127 SF B ACCESSORY STORAGE AREAS 1 102 1OFFICE 129 SF B BUSINESS AREAS 100 SF GROSS 2 103 (OPEN OFFICE 1484 SF B BUSINESS AREAS 100 SF 100 SF 100 SF 100 SF GROSS GROSS GROSS GROSS 16 104 (OFFICE 93 SF B BUSINESS AREAS 1 105 OFFICE 173 SF B BUSINESS AREAS 2 106 !OFFICE 87 SF B BUSINESS AREAS 107 OFFICE 112 SF B BUSINESS AREAS 100 SF GROSS 2 108 OFFICE 155 SF B BUSINESS AREAS 100 SF GROSS 2 1109 OFFICE 137 SF B BUSINESS AREAS 100 SF GROSS 2 110 IOFFICE 131 SF B BUSINESS AREAS 100 SF GROSS 2 111 128 SF B BUSINESS AREAS 100 SF GROSS 2 {OFFICE 112 OFFICE 128 SF B BUSINESS AREAS 100 SF GROSS 2 113 ,OFFICE 131 SF 163 SF 202 SF B BUSINESS AREAS 100 SF GROSS 2 114 'OFFICE B B BUSINESS AREAS 100 SF GROSS 2 ,115 .OPEN OFFICE BUSINESS AREAS 100 SF GROSS 3 116 ;STORAGE 35 SF B ACCESSORY STORAGE AREAS 300 SF GROSS F117 [HALL 349 SF 320 SF 383 SF B B B BUSINESS AREAS 100 SF GROSS 4 1118 BREAK ROOM BUSINESS AREAS 100 SF GROSS 3 119 I OFFICE ! BUSINESS AREAS 100 SF GROSS 8 120 OFFICE 201 SF 121 OFFICE 120 SF GRAND TOTAL: 22 4872 SF 'Out of Scope, --'EXIST. ELEV. 59 OFFICE 102 [2) FILE STORAGE 101 /////l///////// BO DECK CEILING FINISHED FLOOR //C//////i ///:///%//%//i//%/ 1. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK. 2. PROVIDE EXIT SIGNAGE PER 2015 IBC 1009.9, 1009.10, 1009.11, AND 1013. 3. PROVIDE MEANS OF EGRESS ILLUMINATION PER 2015 IBC 1008. KEY NOTES - F & LS PLAN NOTE DESCRIPTION MEANS OF EGRESS PATH ALL THE WAY TO EXIT DISCHARGE, WHICH IS OUTSIDE OF PROJECT SCOPE, TO COMPLY WITH 2015 IBC SECTION 1008 FOR EGRESS ILLUMINATION. CONTRACTOR TO VERIFY EXISTING PATH IS ILLUMINATED MINIMUM OF 1 FOOTCANDLE AT THE WALKING SURFACE. ALSO VERIFY WHICH EXISTING LIGHT FIXTURES ARE EQUIPPED WITH EMERGENCY BATTERY PACKS. NOTIFY OWNER / ARCHITECT FOR FINDINGS AND CONSULT FOR CORRECTIVE ACTION. IF REQUIRED. /I////////li% /////lei//// //////% ////// /l> BO DECK RIGID BRACE AT MAX 8' OC AT ALTERNATE SIDES CEILING 5/8" GYPSUM BOARD 3 5/8" MTL STUD, 16" OC 5/8" GYPSUM BOARD /,// 2 _ //// /////t /// // // // / / ///// / / /// /; / / ://; ///// ' RIGID BRACE AT MAX 8' OC AT ALTERNATE SIDES (2) LAYERS 5/8" GYPSUM BOARD 1 5/8" MTL STUD, 16" OC — 5/8" GYPSUM BOARD, FINISHED FLOOR /i//i',/%//////%//// //i ///// %//%/// i %/////// /////// %/// //1///// /%/////,!////'% /,/%///,'; / ///,%//,// TYPE M01_ RATING - SOURCE UL U465 src 45-49 BATT SOUND ATTENUATION INTERIOR PARTITION TYPES - METAL 3/4" =1-0" OFFICE [21 MAX ALLOWABLE 300'-0" PROVIDED110'-2"_ __ OPEN OFFICE F 103 61 All O\PGONFV NP1ps .---- —113 Of 0APGO OFFICE 109 [2) ADDED COMMON PATH OF EGRESS TRAVEL PER CITY COMMENT OFFICE 104j hl MAX ALLOWABLE 300'-0" PROVIDED 109' - 4" 125'-2 C6SSDOORWpYS EX\TS I EXii AC OFFICE OFFICE L 111 I [21 TYPE M02_ RATING - SOURCE EXISTING WALL TYPE - VIF src 45-49 BATT SOUND ATTENUATION OFFICE L105 / [2) MAX ALLOWABLE 100'-0') PROVIDED 44' - 0" OFFICE 107— OFFICE r 112 [21 OFFICE OFFICE r 114 [2] STORAGE 116 hl ROOM NAME [ $## 1 lul j — - \ ce 7) 0000° \-- WIDTH PROVIDED \- WIDTH REQUIRED ROOM TAG WI OCCUPANT LOAD COUNT DOOR FIRE RATING ASSEMBLY RATING MEANS OF EGRESS CAPACITY LIE Il�J EXISTING FIRE BARRIER, 2-HOUR LT TT C EXISTING FIRE BARRIER, 1-HOUR EXIT SIGN, EXISTING EXIT SIGN, NEW FIRE EXTINGUISHER CABINET, EXISTING TO REMAIN FIRE EXTINGUISHER CABINET, NEW F.E EXIST. WALL MOUNTED FIRE EXTINGUISHER REINSTALLED 4INIE123 <�123 MEANS OF EGRESS EXIT ACCESS EXIT DISCHARGE OCCUPANT LOAD NOTES & LEGEND - RATED ASSEMBLIES BARRIER TYPE & RATING • EW = EXTERIOR WALL • FB = FIRE BARRIER (SEE IBC CHAPTER 7) BREAK ROOM 118, EXISTING AREA _(OUT OF SCOPE) ' L, to 1)19 FRAMING TYPE • E = EXTERIOR FRAMING (VARIES) • M = INTERIOR METAL FRAMING • W = INTERIOR WOOD FRAMING • C = CONCRETE / MASONRY --- 2-DIGIT ASSEMBLY NUMBER SEE ASSEMBLY SECTION — STUD SIZE/ THICKNESS METAL • A = 1-5/8" • B = 2-1/2" • C = 3-5/8" • D=4" • E=6" TYPE M##X,,� - RATING FB 1 HR SOURCE XX X#ik# src 00-99 BATT INSULATION TYPE RATED SYSTEM SOURCE • GA • IBC (TABLE 721.1) • UL RECEIVED a' OF TUKWILA NOV 04.219 PERMIT CENTER 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH,COM I- FE 0 0:c >— CD 0 I 0 CD z o_ 0 z W ict 0 ct F- z 0 z 0 J_ m 0 CCD (- co cog CL. i—L >-J 0 -§ a Q CD PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE 1 1 PERMIT REVISION REVIEIWED FOR! :L N _ I APPROVED - - 10/31/19! LIFE SAFETY PLAN - LEVEL 1 SHEET # LEVEL 1 - LIFE SAFETY PLAN 1/8" =1-0" A01.01 Nig ergusmiLLEN ARCHITECT4IRE INTERIORS PLANNINI VIELAB 120V > /// CAT. 5E CAT. 5E DPP CAT. 5E DPP 0-10V CAT. 5E 120V SPP I 1// CAT. 5E - SWITCH 'a' ON/OFF, DIM UP/DOWN a ()LV TYPICAL ROOM (WITH DAYLIGHT ZONE) AND SWITCHED RECEPTACLES LIGHTING CONTROL DIAGRAM DIAGRAMMATIC 0-10y 2 FLOOR PLAN - LEVEL 1 - LIGHTING RL1 I/J 120V > 120V CAT. 5E DPP I 0-10V CAT. 5E I DPP — 0-10V CAT. 5E RL1 // RL1 //I !gas CAT. 5E [iv - SWITCH 'a' ON/OFF, DIM UP/DOWNa TYPICAL ROOM (WITHOUT DAYLIGHT ZONE) AND SWITCHED RECEPTACLES LIGHTING CONTROL DIAGRAM 3 ) DIAGRAMMATIC PANEL PA' 120V > CAT. 5E DPP 0- OV CAT. 5E RL1E DPP 0_ OV CAT. 5E 120V SPP CAT. 5E rifv - SWITCH 'a' ON/OFF, DIM UP/DOWNa TYPICAL ROOM (WITH EGRESS LIGHT) AND SWITCHED RECEPTACLES LIGHTING --- CONTROL DIAGRAM kDIAGRAMMATIC RL1 RL1 RL1 RL1 RL1 a,o 0 , N a,o gi I o LErg C+PiCE gi RL1 RL1 a,b 0 0 0 FM 0 0 Fr; RL1 RL1 RL1ERL1 RL1 a,ogir a,o Pr - a,o FA prd VARL1 V RL1E 0 0 o RL1 Q(TYP) ' RL1 RL1 0 0 0 b' 0 o IN 4,o , VAb,o 0 b,o N o 0 o D 0 RL -RLI L1 RL1, - RL1,,, RL1 RL1 , 0 RL1E RL1 RL1 RL1 '-' RL1 RL1 RL PA' il,c,itzi rilo 4§10iVAo ° VA0 '* &Pi 0 PI II El Fr -CT. 0 - r4 Pli 0 MI 0 R oll EX1 *".4.451 PA 0 RL1 RL1 ' RL1 RL1 RL1 RL1 RL1 RL1 011ifir:LiE A D V m o RL1RL D D VA m,x 4`I 0 V m, 0 (TYP) RLit,F.RcE RL1 _ PAsVA R 1 RL1 RU RL1 RL1 V :3 RL1 CONNECT NEW LIGHT FIXTURES TO EXISTING MAINTAINED CIRCUIT FROM DEMO PLAN. NEW LOCATION OF EXISTING SPEAKER FROM DEMO PLAN. EXTEND RACEWAY/CONDUCTORS TO ACCOMMODATE NEW LOCATION. NEW LIGHT FIXTURE SWITCHES FOR NEW LIGHT FIXTURES. MAKE ALL CONNECTIONS COMPLETE FOR AN OPERATIONAL SYSTEM. NEW LOCATION OF EXISTING LIGHT FIXTURES FROM DEMO PLAN. CONNECT TO CONTROLS INDICATED ON DRAWINGS. GENERAL NOTES 1. PROVIDE UNSWITCHED (HOT) CONDUCTOR FOR ALL EGRESS AND EXIT SIGN LIGHT FIXTURES. CONSTRUCTION NOTES a RL1 RL1 Li; RL1 RL1 RL1 !FRU° PRIMARY DAYLIGHT ZONE G H ,z RL1 (TYP) RL1 m,y ,LV DRL1 R PAIriVA PA R:1 rAl ea RLI Nct bib RECE1 F.D CITY OF TUKWILA NOV 0 it 2019 PERMIT CENTER 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM >- z 0 F- 0 < ITLU 0> oct Z 0 0 1_111 -z ›- I- 0 Z 0 Ll 03 co z w Co co fit 0) w > Z <F- cp PROJECT # 2017036.20 BID SET SSUE DATE SEPTEMBER 26, 2019 REVISION SCHEDULE ADDENDUM #1 10/31/19 • __ APPROVE', _______...„............._........._.. , - - r 71 ukwiin . „ DIVISION , ," il _0 1 FLOOR PLAN - LEVEL 1 - LIGHTING SHEET # E22.01 1/8" = 1'-0" PROJECT: KCHA Building 600/219-027 GROUP: Office AREA: New Area GRID: New Grid PREPARED BY: BCE Engineers VALUES ARE FC, SCALE: I IN= 2.7FT, HORZ GRID (U), HORZ CALC, Z= 0.0 ROOM REFLECTANCES: 80 / 50 / 20 Computed in accordance with [ES recommendations Statistics GROUP L MIN MAX AVE AVE/MIN MAX/MIN [_(+) 1.18 I 7.75 I 4.07 I 3.46 1 6.59 Y-AXIS 28.84 26.84 24.84 22.84 20.84 18.84 16.84 14.84 12.84 10.84 8.84 6.84 4.84 2.84 0.84 2.05 2.76 3.40 4.36 5.58 6.63 RLI- E 0.80 F + + + 6.10 4.85 3.72 2.87 2.44 2.33 2.53 3.08 4.00 6.4 4 I + -1-- + + + + + + 4-4 + + + I. + + 2.42 3.14 3.77 4.66 5.73 6.60 6.76 6.07 4.87 3.77 2.98 2.54 2.42 2.61 3.13 4.00 5.17 6,26 6,64 6.14 -+- +- 2.87 3.61 4.07 4.67 5.76 5.75 5.77 5.23 4.33 3.47 2.84 2.47 2.37 2.51 2.92 3.59 4.44 5.20 5.48 5.1 3.62 4.33 4.52 4.64 4.76 -L82 4.66 4.24 3.63 3.05 2.59 7.33 2.24 2.33 2.60 3.03 3.54 3.98 4.13 3.90 4.70 5.37 5.26 4.89 5.81 6.53 6.13 5.30 6.55 -4- 6.67 5.55 ---f- 6,19 6.94 6.44 5.37 5.84 5.55 4.85 4,12 4.63 4.59 4.30 .29 3.74 3.91 4.01 3.02 3,09 i2.93 2.31 2,41 2.42 1.33 + + 2.06 2.10 2.09 2.01 + H+ 2.01 2.04 101 1.93 2.16 2.1 2.11 2.53 2.66 2.67 2.56 3.15 3.44 3.29 2.66 3.17 3.55 -LOU 4.56 5.06 5.19 4.85 4.17 3.44 2.87 2.53 2.42 1 2.85 3.35 4.02 4.56 4,68 4.30 2.35 2.85 .4- 3.39 4.14 5.11 6.02 6.37 5.94 4.95 2.18 2.63 3.77 ‘4.17 5.34 6.52 ? -4- 3.91 3.14 2.71 2.56 7.71 3..16 3.95 4.96 5.83 6.02 RLIE I -H- 7.02 6.52 5.33 4.11 3.25 7.75 2.59 7.75 3.27 4.20 5.42 6.5( -; 73 ‘t 910 6.43 6.05 4 92 8- ',,07 2.67 2 45 60 3.03 3.92 5.09 0 01 [ RLIE + 6 1701 6.01i; 25 LitePro 2.029 Point -By -Point Results II/1/2019 + + + 2.85 3.22 3.24 3.08 2.47 + + + + + 3.68 4.32 4.39 4.09 3.16 + + + + 4.63 5.58 5.69 5.20 3.94 5.30 6.45 RLIE . I ..... + + 5.94 4.43 + + ± + + 5.18 6.32 6.62 5.78 4.33 4.58 5.43 5.67 4.80 3.68 + + + 3.72 4.42 4.62 3.61 2.84 + + + + + 3.28 3.82 4.03 2.60 2.04 + + 3.00 3.93 5.21 6.51 6.90 6.06 + + + RLIE 3.18 3.78 4.17 1.96 1.55 2.09 3.14 4.48 5.89 7.27 7.75 + + + .4 4.3( 4.87 1.54 1 -4- 6.79 53 2.81 3.33 4.21 5.41 6.73 7.21 6.4 + + + + + + + + + + + + + + + + + + + 5.45 4.11 2.99 2.28 1.94 1.84 1.88 2.21 2.82 3.63 5.11 6.15 6.03 5.60 4.75 3.76 2.99 2.68 2.71 2.98 3.54 4 IN + + + + + + + + + 4.70 3.46 2.63 1.98 2.04 2.38 3.06 4.10 5.62 6.83 RE I E 6.98 + + + + + + + + 6.46 5.29 4.05 3.15 2.64 2.50 2.62 2.88 3.30 7.5 13 1.93 _I 98 2,28 7.94 3 88 5.20 6.23 6.61 5 98 9( + + + + 2.95 0.62 4.62 8.62 12.62 16.62 20.62 24.62 28.62 32.62 36.62 40.62 44.62 48.62 52.62 56.62 60.62 64.62 68.62 72.62 76.62 80.62 84.62 2.62 6.62 10.62 14.62 18.62 22.62 26.62 30.62 34.62 38.62 42.62 46.62 50.62 54.62 58.62 62.62 66.62 70.62 74.62 78.62 82.62 86.62 X-AXIS REcEivEo orrY TUKW P- A NOV 0 if 2019 PERivla CENTEF-3 Page 1 NOTES & LEGEND - DEMO PLAN EXISTING OFFICES-, (LIMITED SCOPE) 14 II II II II U r 05 Q6, — REF — r rr- = III I 0 I B r----, IL 'O , I I If— o 08 I I o I r— ��� REF__-__T- ENLARGED DEMO FLOOR PLAN - BREAK ROOM 1/4" =1-0" NOTE: 1. EXPAND EXISTING THROUGH -FLOOR CABLING ACCESS FROM SERVER ROOM TO ACCOMMODATE NEW VOLUME OF CABLES. KEY NOTES - DEMOLITION NOTE DESCRIPTION 01 EXISTING FEATURE WALL (BASE, PAINTED MULTI -LAYER WALL PANELS, WALL SCONCE) TO REMAIN. PROTECT EXISTING FEATURE WALL FROM DAMAGE DURING CONSTRUCTION. 02 PROTECT IN PLACE EXISTING TUBE STEEL COLUMN; VIF COLUMN SIZE AND FURRING. REMOVE FINISHES TO BE REPLACED. 03 REMOVE WALL FINISHES TO EXPOSE FRAMING. 05 REMOVE FLOOR FINISH AND WALL BASE. CLEAN, REPAIR, AND PREP FLOOR TO ACCEPT INSTALLATION OF NEW FLOOR FINISH AND WALL BASE. 06 CLEAN, REPAIR, AND PREP WALLS AS NEEDED TO ACCEPT NEW PAINT. 07 DEMO ALL CASEWORK. REMOVE AND PROTECT ALL APPLIANCES; COORDINATE STORAGE AND REUSE WITH OWNER. 08 PROTECT IN PLACE EXISTING RANGE HOOD AND DUCT. 09 DEMO WALL. 10 DEMO WALL AS NEEDED TO ACCOMODATE NEW DOOR PER FLOOR PLAN. 11 DEMO DOOR, FRAME, AND HARDWARE. 12 DEMO PARTITION SYSTEM PANELS AND DOORS. 13 DEMO FEATURE WALL, WOOD BASE, AND WALL SCONCE. 14 PROTECT IN PLACE EXISTING DOOR AND SIDELIGHTS/TRANSOMS. 15 I REMOVE FIRE EXTINGUISHER AND MOUNTING HARDWARE, PROTECT AND STORE FOR REUSE. 16 REMOVE VENDING MACHINES. PROTECT AND STORE FOR REUSE. 17 PROTECT IN PLACE EXISTING STORAGE CLOSET. 18 DEMO WALL AS NEEDED TO ACCOMODATE NEW ELECTRICAL PANEL 19 REMOVE EXISTING ROLLING FILE STORAGE SYSTEM & ALL ASSOCIATED BUILT-UP PLYWOOD FLOOR, RECESSED TRACKS, AND FLOOR TRANSITION TRIM. PREP EXISTING CONCRETE FLOOR SLAB FOR NEW FINISH. 20 REMOVE EXISTING FILM APPLIED ON INTERIOR GLASS PANE, IF THERE IS A GAP IN FILM WHERE DEMO WALL WAS LOCATED, CLEAN EXISTING GLASS FOR NEW FILM TO BE APPLIED. VERIFY SCOPE OF WORK. 21 SALVAGE EXISTING PORTABLE FIRE EXTINGUISHER FOR REUSE IN NEW CONSTRUCTION OR TURN OVER TO OWNER FOR FUTURE USE IF EXISTING FIRE EXTINGUISHER DOES NOT MEET SPECIFICATION. REFER TO KEY NOTE ON NEW FLOOR PLAN. DEMO FLOOR PLAN - LEVEL 1 1/8" =11-0" 22 EXISTING FLOOR FINISH TO REMAIN IN THIS ROOM. 23 EXISTING WALL BASE TO REMAIN IN THIS ROOM. EXIST. ELEV. MACHINE 06 05 06 '13- 09; 1. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK. 2. BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. CONTRACTOR TO REFERENCE SPECIFICATIONS FOR PROTECTION OF PUBLIC SAFETY AND PROPERTY. 3. CONTRACTOR TO PRESERVE AND PROTECT EXISTING BUILDING SYSTEMS TO REMAIN. 4. CONTRACTOR TO COORDINATE REMOVAL AND STORAGE OF EXISTING FURNITURE, FIXTURES. AND EQUIPMENT DURING CONSTRUCTION WITH OWNER. 5. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION WORK. NOTE: 1. REMOVE BLINDS AND HARDWARE. PROTECT AND STORE FOR REUSE. 09; 05: 06,, s 05 05; ,06; 05 06i z FEATURE WALL ANNOTATION TAG ROOM NAME TYPICAL ROOM TAG ;21 / r 06 00-11 ROOM NUMBER CONSTRUCTION ELEMENTS C= EXISTING ELEMENT TO REMAIN DEMOLISHED ELEMENT RergustuILLEn ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM Z I- O © < F— O z Q Z (-7.) O O LLI — Z>- I— 0 z_ O M W Z O I— uJ co co o 0) Q Q CC LU < O _J 0 Z � Q F- OO CD PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE +! l :)IVist6 DEMO FLOOR PLAN - LEVEL . I Y OF SEP 2 5_ _201L F SHEET # D21.01 KEY NOTES - DEMO RCP NOTES & LEGEND - DEMO PLAN RicergustALLER # NOTE DESCRIPTION 1 REMOVE & RELOCATE EXISTING SPRINKLER HEAD. SEE NEW REFLECTED CEILING PLAN FOR NEW LOCATION. NOTE: 1. THIS DASH INDICATES THE APPROXIMATE LOCATION OF EXISTING GYPSUM WALL & ASSOCIATED FRAMING ABOVE FINISH CEILING. FIELD INVESTIGATE EXISTING CONDITION & VERIFY POTENTIAL ADDITIONAL SCOPE OF WORK AT ABOVE CEILING. REFER TO MEP SHEETS. 1 1 1. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK. 2. BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. CONTRACTOR TO REFERENCE SPECIFICATIONS FOR PROTECTION OF PUBLIC SAFETY AND PROPERTY. 3. CONTRACTOR TO PRESERVE AND PROTECT EXISTING BUILDING SYSTEMS TO REMAIN. 4. CONTRACTOR TO COORDINATE REMOVAL AND STORAGE OF EXISTING FURNITURE, FIXTURES, AND EQUIPMENT DURING CONSTRUCTION WITH OWNER. 5. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION WORK. NOTES: 1. PROTECT IN PLACE EXISTING CEILING GRID. 2. EXISTING CEILING SPEAKERS TO BE REPLACED AND RELOCATED. COORDINATE EXACT LOCATIONS WITH OWNER. 3. REMOVE ALL CEILING TILES, LIGHT FIXTURES, GRILLES, AND DIFFUSERS. ANNOTATION TAG ROOM NAME TYPICAL ROOM TAG ROOM NUMBER NOTES: 1. PROTECT IN PLACE EXISTING CEILING GRID FOR REUSE IN THESE ROOMS. 2. REMOVE ALL CEILING TILES & LIGHT , 1-1 FIXTURES, GRILLES, DIFFUSERS, & ,- ACTIVE INTERCOM SPEAKERS (IF , i \ APPLICABLE) IN THESE ROOMS. ! ! I PI : : 9 irt!= =ir-- 41:1 -7 4..t: !L ,- i • , . • ! ; if ` u ; 11 \ / II ; . • i---_4 ,-- , '':: ; ''.1:'• : I It; ilH it 51 1 [ : l' ;r1 51-;{-/ 11 . . : 4 , • . . , ii :, ,. tr- - - - -II - -i• ' i- - 4 - -i::: •,-; 1 rt -i-------I---- ! 4-; - _ _ . , , •--1 r• ", • •-, f 4 • — . 1'1 i r ::---1 il `' r — —1 r — —I „, 1 ' ---1 ! i 1 1, , „, I! • I'. i 1 • L _.„,„._.._., ! • , „ • ! L = = = D 1 1 , • , „ , , , ; • , , ! ! e o ---•,! 1 1 if- 4 • I „ .. • i'l i, 5 . q 11 ' CI I < , I 't r- —4 4 4,... _ ,..,1 ! „ i 1 1- I I 1 1 -1 11 4 1- 0 i 4,- 1:: 1 i_ I- - -L • ______ • 1 --!°- - , - '- i•-• - . - -7 4 I-- - I - -I- 1 I 1 -A- ---!- + r-----e- I , -i- , i — ----- , , , • , --1:-, = = 1-- lit-7-: ' -1-----1 r, , . ,31 :„. II `, 11 , ii , , , „t„....,.„-A. ; • ! _,L, „1-. -4 • ii_ . . -LI IP - ii --, . ! . II, " 11 ' r - - -1 ! - I 1-,41 i„ .._ 1 , 11 H—r - -11---i-, -- '1'i • -mil 1 1r !,,!! ' --"--r! • - „, 1 = ;,..'1' \--14,1'1' f41• 1111:111'till'Il':!!1' t•Iti ! : lit • I i 1 7 ITC: : :: 1,14i1 14,1_,:: _-_-...121 1 1® : - 44. : 0 H___1_ _ _ _ ,:it,.. - at, t- - -i_i 1 /4- 1 : , II 41.- -4 !.-'. -4- i-1- -_, 1:- -1-1 *-4-r-1-1 --4-- ur-t j- - t- _...0., ,..1 ,,..,..., ,,,,,„ . .. ; -I- 4-: , :r" , -re , • . . . , i- — Ilie ,1$ '4 -i` :-, \ 4' ''' -9 utt" t -i - --ti i-----41/4-- - -11 •'• ; ; -!- • . . . -II I- - -I I , • . • , , • , . , . • • . . , • „ • • , • • . , • • ; i , ; • ; . .. • . ; „ „ ; •• I ' 1 1 It- - -tt- - ,{ ; 4- 1 -* - --tK - -,tr 4- 1 ; I : 4.. HI- ---71:-.:14 - 1: 1-- 5; :i•- ---74: 1 1- -1 1; , _ ; 1 1 : 1 0 ! i.Fe1 --,714„:7-47, :-H-117-11,1:1,fLii 1 .• . • 1 Lt ! ,14; ! 1 )(11_,..„....4__ , - "; : : 4 • ! ; i 1 .EXISTING AREA,,, (OUT OF SCOPE) EXISTING AREA , n , , , ; • Id I 1 I - 11 ; ; F 4— 4- 1 I ! , s , s ; ....I — I! _t. ;.- - r \/it 'T -4 + *,,,,,,,,,,. ., , .., , , . K 1 ,,'-o,...i, t---a" "1-.. lk 1 IT 1 s F`l : 1 • i • . , ii \ \ II f.... '''....4,----- HI— • — i". '. -1- 1 )1(OUT OF SCOPE)_.' , • 11 - - , - i , I ,' - - • 1; _ _ _i____ i____k - 41______•....._. i 1- - -1 ' ,• i ••• 1 ; I I , I .--, .... i J 1 t_ 1 1, i ; ; E • 1, • , , •- a- ,', ti ; i *,., .,,,!„.•••-----,--"—:7.--„•-••-•• ,--4---f-P-'1. ,'''''..s--=.=,4, 144.-- 1-,-,4,4„,...4,,,,444 , ._ 1-4-__, 1 i , • - --1 41 1 44 4-, I I 44, 1 117101.4 1r'•,' '1'1'1 \-!!'"'T----"H 1 '•! 1 _----A .1 ! r0;- - 1 ; ; , . i ; .., • !!!!!!!:1 4- - -11: N .21-- -4 , • . ; 1 , 4_1 ,.., 0 1 I )( ;I i i [4 , . , . 4! ! 15, 1 ;4400-10" 1 I I _ _ 1 0 ... ... !ikr: - -ld:1 ...''' - 4 4-- ; 4 -__4_---.4 __; ; ;_ -E ; ..,•A- - - ;11- -I- —I_ .sts -1.-^ -1--/,' - '-ir 1- i 1 ; ; -,,,44.44,-; ! ; • ! 4, \ ! 0 1 1 I= ..4 — —I1 . . s . , ' ,' \ \ — si t't ; • 1 , I i 1 -n----- ---r--- ---------!------- ,'-q-,---. -.-,4 1r,----- , m-7— ---::--. • ; , , ,'"' t.• , i s , . i 1,1 I '<" { — 11 I -. l , , 1 1 1 L I I : I i 1 1 I i 1 I i -..,........----...--,-,-.-.1 4. 1 1 ' s s /1-': 41 _ 4 4 - ;-11-; - • • j. 1 -1' i I I ! - t- '7 — —tr," - ; • 1 0 I- 2 3 (II IC: _ - 1 0 ii -,;•;,;:•••;;;;„;;;;;;;;;;;;;;„;F_IF, _„ • : _ j • TD / 1 • 0)(11 - - - - I. • — • 4 - "if 1 II ! ! • 11 11 1-1 1 ! 1 11 1- -71 1 1 1 : ; 1 !, )( • - ir - L„, t 1I 11 1 - / \ , —1 II 11 11 11 UiI = ti _ 1111.11 \ = !— H. , • • • • • • ,••• tit 4 • • - - • 11 II !; 1 II )4' II — -1 „:11 x I : 11 11,; • 1 -4- - -41 n 12;'1-•, u • : .• _T, 7 1 .t; CONSTRUCTION ELEMENTS EXISTING ELEMENT TO REMAIN DEMOLISHED ELEMENT 't= ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM z 0 e< > 1. 0 CD (7) 0 1-1-1 Zi— Z Z 0 CO CD CD 600 ANDOVER PARK WEST TUKWILA, WA 98188 PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE 1 ; ' • REVIEWED POR —1 ANCE-{ --APPROVED+ ----- U)LfiN(aHV)SNik' of kwi DEMO REFLECTED CEILING PLAN - LEVEL E 74-77; 1 ff.ITY_CD:41 SEP 25 2019 „T.:7P DEMO RELFECTED CEILING PLAN - LEVEL 1 1/8" = 1'-0" SHEET # D22.01 KEY NOTES - FLOOR PLAN NOTES & LEGEND - FLOOR PLAN ENLARGED FLOOR PLAN - BREAK ROOM 4" = 1-0" 1 (4) C3D " 1 I "----------r; "I : , - NOTE DESCRIPTION 01 EXISTING FEATURE WALL, WOOD BASE, AND WALL SCONCE. 02 FURRING OVER EXISTING COLUMN TO CAPTURE WORKSTATION ELECTRICAL WIRING. 03 NEW GWB AND WALL FINISHES OVER EXISTING FRAMING TO MATCH ADJACENT WALLS, 04 WORKSTATIONS, OF01. COORDINATE ELECTRICAL AND DATA CONNECTION LOCATION WITH OWNER. WORKSTATION SIZE, CONFIGURATION, POSITION SHOWN AS REFERENCE ONLY. VERIFY FINAL DESIGN WITH OWNER, 06 ADA-COMPLIANT REFRIGERATOR WITH ICE MAKER, OFCI. 07 PROVIDE STUB -OUT FOR EACH REFRIGERATOR WITH ICE MAKER. COORDINATE PIPING CONNECTION LOCATION WITH OWNER. 09 EXISTING RANGE HOOD AND DUCT. 10 ADA-COMPLIANT RANGE, OFCI. 11 ADA-COMPLIANT SINK AND FAUCET. PLUMBING SYSTEM TO BE DESIGN / BUILT BY CONTRACTOR. CONSULT OWNER FOR PREFERED SINK AND FAUCET. 12 'ADA-COMPLIANT DISHWASHER, OFCI. 13 COUNTERTOP WITH (3) WASTE CHUTES, EQUALLY SPACED. 14 REINSTALL EXISTING FIRE EXTINGUISHER. 15 WORK COUNTER. 16 ADJUSTABLE SHELVES AND SHELF BRACKETS. 17 1'ELECTRICAL PANEL 18 SEE ELECTRICAL FOR VERTICAL RACEWAY INFORMATION, 19 PLASTIC GROMMETS 20 FILL EXISTING STUD CAVITY WITH DENSPACK INSULATION. 21 NEW WINDOW FILM APPLIED TO ENTIRE AREA OF EXISTING GLASS INCLUDING AREA • BEHIND THE END OF NEW WALL. MATCH EXISTING WINDOW FILM. SEE DEMOLITION DRAWING KEY NOTE & VERIFY SCOPE OF WORK. • 22 NEW SEMI -RECESSED NON -RATED FIRE EXTINGUISHER CABINET. REUSE EXISTING FIRE EXTINGUISHER IF ITS TYPE IS 2-A:B:C. IF NOT PROVIDE NEW. 23 CONTRACTOR TO COORDICATE AND PROVIDE NEW WATER SUPPLY LINE FOR FILTERED WATER DISPENSER BY THE OWNER. MO1C OFFICE; 102 102 10-6 1/8" FILE STORAGE 101 1, CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK. 2. BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. CONTRACTOR TO REFERENCE SPECIFICATIONS FOR PROTECTION OF PUBLIC SAFETY AND PROPERTY. 3. CONTRACTOR TO PRESERVE AND PROTECT EXISTING BUILDING SYSTEMS TO REMAIN. 4. DIMENSIONS ARE TO ROUGH FRAMING OR TO FACE OF EXISTING FINISHES, TYP UNO. 5. DIMENSIONS INDICATED AS "MIN" OR "CLR" ARE FROM NEAREST FINISH SURFACE, INCLUDING TRIM. 6. ROUGH DOOR OPENINGS ARE LOCATED 4" FROM NEAREST INTERSECTING WALL FRAMING, TYP UNO. 7. WALL FINISHES SHALL TRANSITION AT INSIDE CORNERS, TYP UNO. 8. FLOORING TRANSITIONS SHALL FALL UNDER DOOR LEAF, TYP UNO. SEE DETAILS ON SHEET A71.01. 1.-7 7/8" MO1C • rMO1C - 'CPT-1' 101 ENLARGED FLOOR PLAN - COPY / WORK ROOM 1/4" = 1'-0" 18 FILE STORAGE 101 01 _ — — • tr I EXIST. • " ELEV. 21 .012 CLEAR 'TILE-0 CPT-1' 18 • 'CO-1 0 > •,?• 37'-4" CLEAR FOF TO FOF , ALIGN FOF _ EXIST. 7 ELEV. MACHINE ' OFFICE, 109 OFFICE 108 OFFICE 110 M01E 19 -- 15 WORK ROOM 100 17) NOTE:REINSTALL SALVAGED BLINDS NX ISTING LOCATIONS. iE t OFFICE ; 104 • • • CG-1 OPEN OFFICE 103 MO1 C EQ OFFICE 111 ". • • (CG-1, I-MO1C OFFICE 105 OFFICE 106 OFFICE 107 OFFICE_ 01 HALL 117 EQ EQ, MO1C 03 MO1C MO1C ' .F1.01,4 OFFICE 112 21 21 121 MO2A OFFICE 11 a ( F OFFICE 119 OFFICE 114 OFFICE 120 0 z C.9 -J ANNOTATION TAG ROOM NAME ; ### FIN-1 FIN-2 TYPICAL ROOM TAG ROOM NUMBER CONSTRUCTION ELEMENTS EXISTING ELEMENT TO REMAIN NEW CONSTRUCTION ELEMENT FLOOR FINISH TRANSITION -NI TRANSITION LINE NON -TYPICAL WALL FINISH EXTENT STO116RAGE CLEARANCES 1.-6" CLEAR 1'-0" CLEAR A70.01 M. 5'-0" CIRCULAR TURNING AREA 30" X 48" CLEAR FLOOR SPACE DOOR CLEARANCE AT PULL APPROACH DOOR CLEARANCE AT PULL APPROACH MO1C CO-1 in CG-1 ENLARGED FLOOR PLAN - STORAGE 1/4" = 1'-0" REF ; REF BREAK ROOM 118 .20 .• EXISTING AREA 2 - -- (OUT OF SCOPE) 1 22) . _ . _ ,, ___,................., . OG-,2 - n 4121821-1 1, , - ALIGN FOF 1, ,------; \ T-4" I STORAGE 1 116 ; ; OPEN OFFICE 115 418 G CHD mrafergusteiLLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM >— z I.-0 cx I= > I. <w Ct Z C7) Ct CD ILI z I- 0 Z a 0 5 (.9 co z )) LI.J Co c7c; 0") < < 0_ < > 0 § Z < CD PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE :REVIED FOR CODE COMPLANCE APPROVED ROV 4 Cty B 1L \c'i Gf: Tru) ki 0 N FLOOR PLAN - LEVEL 1 RECE:vED SEP _2 5 204 FLOOR PLAN - LEVEL 1 1/8" = 1'-0" 4XYG‘ t)4\ A21.01 NOTES & LEGEND - REFLECTED CEILING PLAN CA9 Cp) 1, ! • 1 ' •, OFFICE 102 • FILE STORAGE 1. ARCHITECTURAL RCP PROVIDED FOR COORDINATION PURPOSES ONLY, 2, WHERE NEW WALLS NECESSITATE THE NEED TO MOVE, ADJUST, OR RELOCATE EXISTING LIGHT FIXTURES, MECHANICAL GRILLES AND DIFFUSERS, OR OTHER MECHANICAL AND/OR ELECTRICAL RELATED SYSTEMS, CONTRACTOR TO COORDINATE WITH ARCHITECT. 3. CEILING FIXTURES ARE CENTERED IN CEILING TILE OR CENTERED IN ROOM, TYP UNO. 4. DIMENSIONS IN CEILING PLANS ARE TO FACE OF FINISH, UNO. 5. GRAPHIC REPRESENTATION OF LIGHTING TYPES MAY NOT BE TO SCALE. ANNOTATION TAG ROOM NAME TYPICAL ROOM TAG ROOM NUMBER CEILING TYPE CEILING TAG HEIGHT CEILING ACT 2X4 SECOND LOOK FIRE PROTECTION NOTE: NOTE: 1. COORDINATE LOCATION OF NEW CEILING - 1. PROVIDE NEW CEILING TILES & NEW SPEAKERS WITH OWNER. LIGHT FIXTURES. 2. PROVIDE NEW CEILING TILES, LIGHT FIXTURES, GRILLES, AND DIFFUSERS WITHIN EXISTING CEILING GRID. T ' ' r,zOFIF2ic-€47,:: I7 0 : :,,L,,,,,_,„_-, ''''''''----:• lj-ii_ , •, , , ,, , i , M - ,. ; ,,' 1. j'. 1-, • / • , 0 '•,, OFFICE \\< 104 ." • • • • 1 1,..J OFFICE t WORKROOM • E 120 . • . . }1.„ -d • • • 1r: • • EXISTING SPRINKLER HEAD (FIELD VERIFY LOCATION) NEW SPRINKLER HEAD .' ----11.-------., CI ! IIII ' 4 • If : . ' • • a. BREAKROOM- 0- • - 118 !! ® • !! -- !„ 01, .1 I , ! OPEN OFFICE EXISTING AREA 5. • J ' 1030ICE „0.! • : OFFICE • OFFICE 119 _ EXISTING AREA „ (OUT OF SCOPE) IscopE, (OUT OF SCOPE) 'I! • 'j -1 - _ I It- • , ,; • LI:11 • r ; , IlL.*:,11111. I /I / I - I ' OFOICE J-1 • 1117 ! I I ' I t I jr• I j • f .1 117 ; • • : . t - • „ 11--±1 •; STORAGE • 116 !!!! • • I ' 0„1 •11 \!"! 11 117. -0 • : 1 I, • ! 11 ! * ®! : „i • '[ X '1 • : 2:t•: „t„:= : •111—®! - -„, ! ! , I * OFFICE OFFICE OFFICE OFFICE OFFICE - OFFICE OFFICE _OPEN OFFICE . : , • , 108 109 110 111 112 113 114 115 CONSTRUCTION ELEMENTS EXISTING ELEMENT TO REMAIN NEW CONSTRUCTION ELEMENT LIGHTING MECHANICAL EXISTING RECESSED DOWNLIGHT NEW RECESSED DOWNLIGHT RECESSED TROFFER. 2X2 WALL SCONCE ' EXHAUST RETURN GRILL SUPPLY DIFFUSER RIC ergusaiLLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM cr) 0 0 c.) CD z RUMS R ARCH T A BELDING, SH I N1U� z F- 0 LU 0 F- z z 0 z —1 CO CO 600 ANDOVER PARK WEST WILA. WA 9818 PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE !' REVIEMED FOR CODE COMPLIANCE 1 J., luicwita CBUILDING-tDiViSION REFLECTED CEILING PLAN - LEVEL 1 alTy .0.F TUKWILA. SEP -2 5 2019, ti El:n117 CENf4 REFLECTED CEILING PLAN - LEVEL 1 1/8" = 1'-0" SHEET # A22.01 ergusMLLER ARCHITECTURE INTERIORS PLANNING VIZLAB co FIN FLOOR FRAME TYPES FIN FLOOR 2"-SEE SCHEDULE- 2" k 4 01 SEE SCHEDULE 8" 6"I t GL-2 i �i ILM-1; 2"--SEE SCHEDULE, 2" 36" 02 SEE SCHEDULE 2" SEE SCHEDULE FILM-1'J 03 SEE SCHEDULE 6" 2'-0" 6"1. GL-2 FILM - DOOR TYPES D1 SINGLE NARROW DOOR & FRAME TYPES D2 SINGLE FLUSH D3 SINGLE HALF NOTE: GL-* SEE SPECIFICATION 088000 FOR GLASS TYPS. DOOR SCHEDULE DOOR ROOM DOOR INFORMATION FRAM E INFORMATION �-- _ _--_' HARDWARE �, HEAD i JAMB # NAME : TYPE MATERIAL FINISH , GLAZING HEIGHT WIDTH THICKNESS TYPE [1 MATERIAL', FINISH GROUP ,! DETAIL DETAIL r 101 FILESTORAGE D2 WD - " STAIN T 3 0 1 4 1 0 3/ 0 HM P 6 ' 02 101A70.01 9/A7 . 102 OFFICE 1 D1 WD STAIN GL-2 ! 7' - 0" 3' - 0" ;1 3/4" 01 I HM ! P-6 01 10/A70.01 9/A70.01 1 HARDWARE TO MATCH EXISTING OFFICES. 1 10 8 OFFICE ' D2 WD !STAIN - T - Q" 3' 0" I 1 314 2 ! HM P 01 1 7 . 0 6 OIA 0 01 9tA10.01 HARDWARE TO MATCH EXISTING OFFICES. COMMENTS 109 OFFICE ; D2 WD STAIN - T 0" 3' - 0" 1 3/4" 02 KM P-6 01 10/A70.01 9/A70.01 !HARDWARE TO MATCH EXISTING OFFICES. 110 I OFFICE D2 I STAIN I -- 7' - 0" 3' - 0 1 3/4" 1 02 I HM P-6 01 10/A70 01 9/A70.01 !HARDWARE TO MATCH EXISTING OFFICES. 111 OFFICE D2 WD STAIN - 7' - Q" 3' - 0" 1 3/4" 02 HM P-6 01 10/A70.Q1 91A70.01 HARDWARE TO MATCH EXISTING OFFICES. �112 •OFFICE D2 WD STAIN - T- 0 3' - 0" 3 HM 7 1 /4 02 P-6 01 10l 70.01 9/A 0, 1'HARDWARETI FFI A Q TO MATCH EXISTING OFFICES. 113 OFFICE :D2 WD STAIN - 7' - 0 3' - 0" 1 3/4 02 HM P-6 01 10/A70 01 9/A70.01 HARDWARE TO MATCH EXISTING OFFICES. 114 OFFICE D2 WD STAIN -- ' T - 0" 3' - 0" ;1 3/4" 102 1 HM I P-6 TO1 10/A70.01 9/A70.01 HARDWARE TO MATCH EXISTING OFFICES. 116 STORAGE D2 I I STAIN- _... _ __ 7' - 0" 3' - 0" 1 3/4" 01 I HM P 6 02 10/A70 . 70 01 9(A70.Oi a - 118 HALL D3 WD ;STAIN ; GL 2 T 0" 3' - 0" 1 314" 03 ; HM P-6 ! 03 ,10/A70.01 i 9/A70.01 GENERAL DOOR SCHEDULE NOTE 1. EXISTING TO REMAIN DOOR FRAMES WITH BARROW LITE FRAMES AT OFFICES 104,105,106, & 107 TO RECEIVE FRESH COAT OF NEW PAINT. PAINT COLOR: P-6. 2. EXISTING TO REMAIN DOOR FRAMES AT EXISTING REST ROOM (SOUTH OF BREAK ROOM) TO RECEIVE FRESH COAT OF NEW PAINT. PAINT COLOR: P-6. 3'-0" 3'-0" /3/4" SCRIBE 2 71.02 A71.02/ 5-0" 6'-0" -- CASEWORK SCRIBE, TYP CABLE TRAY 8 INTERIOR ELEVATION - WORK ROOM VIEW 2 1/4" =1'-0" WALL DIMENSION PER ASSEMBLY 1/2"- 12" - HEADER; STRUCTURAL DESIGN AND DETAILING BY THE CONTRACTOR. HOLLOW METAL FRAME NOTE: SIMILAR JAMB CONDITION GLAZING P HM TRANSOM/SIDELIGHT HEAD "= 1,-0" TAG T SPEC # MATERIAL MANUFACTURER ACOUSTICAL CEILING TILE 10 WALL DIMENSION PER ASSEMBLY 1/2 TYP HM DOOR HEAD 1/2" DOOR HEADER; STRUCTURAL DESIGN AND DETAILING BY THE CONTRACTOR. -HOLLOW METAL FRAME DOOR AS SCHEDULED 3" = 1'-0" INTERIOR FINISH LEGEND PRODUCT FINISH ACT-1 09 51 23 'ACOUSTICAL CEILING TILE ! ARMSTRONG :FINE FISSURED SECOND LOOK CARPET CPT-1 09 6813 LINOLEUM MODULAR CARPET TILE 1 INTERFACE f LINO-2 09 6516 PAINT LINOLEUM P-5 09 91 23 1P-6 1 09 91 23 LAMINATE PLASTIC PLAM-5 ! 06 40 23 PLAM-6 06 40 23 RESILIENT RES 1 1096513 SIMULATED STONE SOL-1 ' 06 40 23 INTERIOR PAINT INTERIOR PAINT I HIGH PRESSURE LAMINATE I HIGH PRESSURE LAMINATE RUBBER BASE SOLID SURFACE VARIOUS FORBO MARMOLEUM 'SHERWIN WILLIAMS SHERWIN WILLIAMS FORMICA i :WILSONART JOHNSONITE TRANSLUCENT FILM OVERLAY FILM-1 09 51 23 TRANSLUCENT FILM OVERLAY WALL PROTECTION CG-1 :09 29 00 [ CORNER GUARD CG-2 09 29 00 END -WALL GUARD 3/4" SCRIBE, CASEWORK SCRIBE, TYP CABLE TRAY ;DON 3M INPRO INPRO 3'-0" NOTES WHITE; ANGLED TEGULAR FIELD ACOUSTICAL CEILING TILE 15/16" EDGE; PATTERN II VARIOUS SEE SPECS - DESIGN TO MATCH EXISTING AT KCHA 700 BUILDING; INSTALLATION: BRICK ASHLAR SW7009 - PEARLY WHITE ' EGGSHELL WALL PAINT COLOR MATCH EXISTING. EGGSHELL DOOR FRAME PAINT CHESTNUT WOODLINE MATTE TYPICAL FINISH FOR ALL CABINETS SHEER MESH FINE VELVET TEXTURE FINISH FOR WORK ROOM COUNTERTOPS I4" WITH TOE 140 FAWN STOCK SOLID SURFACE ACRYLIC. SALT & - !PEPPER BASIS OF DESIGN: FASARA GLASS FINISH [MATTE CRYSTAL FILM FINISH FOR BREAK ROOM COUNTERTOP, 1/2" THICK r z 0 z w 0 I --5/8" TYP HM DOOR JAMB 3" =1'-0" HOLLOW METAL FRAME - DOOR AS SCHEDULED PLAN VIEW INTERIOR FINISH SCHEDULE BY ROOM ROOM INFORMATION FINISH INFORMATION, TYP UNO NUMBER NAME WALL BASE FLOOR ' CEILING 100 WORK ROOM ' P5 `RES-1 CPT-1 ACT-1 �101 FILE STORAGE P-5 LINO 1 LINO-1 ACT-1 1 102 OFFICE P-5 RES-1 CPT 1 ACT-1 103 [OPEN OFFICE P-5 RES-1 CPT 1 AAA • 104 OFFICE P-5 RES-1 CPT-1 ACT-1 105 OFFICE P-5 RES 1 CPT-1 ACT-1 1Q6 (OFFICE P-5 RES-1 CPT-1 ACT-1 107 OFFICE P-5 RES 1 CPT-1 AGT-1 108 OFFICE ' P-5 :RES-1 CPT-1 ACT-1 109 I OFFICE 1 P-5 [RES-1 1 CPT-1 ACT-1 1101'OFFICE P-5 RE -1 CPT- T-1 S 1 AC 111 OFFICE 1 P-5 RES-1 1 CPT-1 ACT-1 112 1OFFICE P-5 !RES-1 !CPT-1 ACT 1 113 OFFICE P-5 I RES 1 CPT-1 I AC__ 114 !OFFICE P-5 I RES-1 ' CPT-1 ACT-1 115 !OPEN OFFICE P-5 ' RES-1 CPT-1 !ACT-1 116 I STORAGE P-5 LINO.1 LINO-1 ACT-1 117 1 HALL P-5 RES-1 I CPT-1 ACT-1 118 1 BREAK ROOM I P-5 LINO-1 , LINO-1 1 ACT-1 TRANSOMS 119 OFFICE EXIST RES-1 1 CPT-1 ACT-1 120 1 OFFICE I EXIST RES-1 !CPT-1 ACT-1 121 1 OFFICE ,EXIST 1RES-1 =CPT-1 ACT-1 DESIGN TO MATCH EXISTING OFFICES SIDELIGHTS AND fi SURFACE MOUNT, 1-1/2" WING @ 48" HIGH STAINLESS STEEL MOUNT 4" ABOVE FINISHED FLOOR SURFACE MOUNT, 2" WING @ 48" HIGH ! STAINLESS STEEL MOUNT 4" ABOVE FINISHED FLOOR OPEN BEYOND INTERIOR ELEVATION - WORK ROOM VIEW 1 1/4" = 1'-0" EXISTING RANGE HOOD AND DUCT REFRIGERATORS WITH ICE MAKER, OFCI M' STUB -OUTS FOR REFRIGERATORS WITH ICE MAKER - ;RES-1 2" BACKSPLASH -- & SIDESPLASH 2'-10" TO TOP OF +► SURFACE -MOUNTED SINK RIM RANGE, OFCI 3'-3" 2 5/8"' , 2-6" EOEO' 2'-6" 6'-0" 2'-10" 6'-0 3/4" ADJUSTABLE SHELVES & SHELF BRACKETS, OFCI 4" BACKSPLASH & - SIDESPLASH CONCEAL MOUNTED KNEE BRACE AT NEW WALL RES 1 INTERIOR ELEVATION - STORAGE VIEW 3 1/4" =1'-0" - FINISHED CASEWORK PANEL TO MATCH CABINETS EXISTING MICROWAVES, OFOI 2" B1kl PLASH & ESPLASH 2` d'"TOTOPOF SURFACE-MOUNTEDo SINK RIM A" SCRIBE ORES 1 3/4" SCRIBE,. WASTE & RECYCLING - RECEPTACLES,OF01 DISHWASHER, OFCI INTERIOR ELEVATION - BREAK ROOM VIEW 4 INTERIOR ELEVATION - BREAK ROOM VIEW 3 4 1/4" = 1'-0" 1/4" =11-0" E 9 TYP / 10 ' 6 71.021 `,A71.02 ,A71.02/ A71.021 2'-0" 3'-0" ----- MINIMUM CLEAR WORK SURFACE PER ANSI 117.1 RES-1 3-4" 2.-0 3/4" E0 INTERIOR ELEVATION - BREAK ROOM VIEW 2 1/4" =1'-0" -- ADJUSTABLE SHELVES & SHELF BRACKETS, OFCI 4" BACKSPLASH & SIDESPLASH - CONCEAL MOUNTED KNEE BRACE AT NEW WALL RES-1; INTERIOR ELEVATION - STORAGE VIEW 2 1/4" =11-0" REFRIGERATORS, OFOI " 1 OF TUKW:!, SEP 2 5 2019 PERMIT CENTER 2" BACKSPLASH & SIDESPLASH PIPING CONNECTION AND STUB -OUTS FOR REFRIGERATORS WITH ICE MAKER INTERIOR ELEVATION - BREAK ROOM VIEW 1 /4" = 1'-0" 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM R!N.BTER!D ARCIKTECT 00 i z >— I -- 0 Zz En— o J D0 W z ct W co Ce Q Q 0 J_ Z Q CD PROJECT # 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE L V)EWE (.1FC 1 F COI APPROVED ROVED INTERIOR ELEVATIONS, FINISH SCHEDULE & DOOR _ SCHEDULE SHEET # A70.01 19 VARIES. SEE PLAN SEE INTERIOR PARTITION TYPE REMOVE EXISTING WINDOW BLINDS. STORE & PROTECT FROM DAMAGE DURING CONSTRUCITON. REINSTALL EXISTING WINDOW BLINDS AT THE SAME LOCATION - TYP. FOR ENTIRE PROJECT AREA. 2" MATCH EXIST. WINDOW FRAME WIDTH TYP. PLAN DTL SECTION - WALL TO EXIST EXT GLAZING STUD FRAMING FULL HEIGHT OF THE WALL STUD FRAMING ABOVE WINDOW SILL. 3/8" THICK CONTINUOUS NEOPRENE STRIP /-- NEW ALUM BRAKE METAL L CLOSURE TRIM FASTEN TO NEW WALL. MATCH EXISTING WINDOW FINISH. EDGE OF EXISTING WINDOW STOOL NEW CONTINUOUS WINDOW FILM, MATCH EXISTING - EXISTING INSULATED GLASS UNIT NEW ALUM BRAKE METAL FRAME FASTEN TO EXISTING HEAD & SILL FRAME 3" =1'-0" 7 19 A71.01 EXISTING STOREFRONT GLAZING NEW BRAKE METAL ALUM FRAME GWB -- CONTINUOUS NEOPRENE BETWEEN METAL STUD AND NEW BRAKE METAL ALUM FRAME METAL STUD FRAMING, TYP NOTES: . TYPICAL WHERE NEW FRAMED WALL INTERSECTS EXISTING EXTERIOR WALL. 2. WALL ASSEMBLY PER FLOOR PLAN LEVEL 1 AL 0" /. DETAIL SECTION - WALL TO EXIST EXT WALL 1/2" = 1'-0" / / CARPET PER INTERIOR FINISH SCHEDULE TRANSITION STRIP - EXISTING CARPET EXISTING SUBFLOOR NOTE: ENSURE THAT CHANGES IN LEVEL OF FLOOR SURFACES NOT TO EXCEED 1/4" PER 2009 ICC A117.1 / - CARPET PER INTERIOR / FINISH SCHEDULE /- TRANSITION STRIP LINOLEUM SHEET FLOORING PER INTERIOR FINISH SCHEDULE SUBFLOOR LEVELER; FEATHER SUBSTRATE TO OBTAIN SMOOTH UNIFORM TRANSITION --- EXISTING SUBFLOOR NOTE: ENSURE THAT CHANGES IN LEVEL OF FLOOR SURFACES NOT TO EXCEED 1/4" PER 2009 ICC A117.1 NEW CEILING TILE AND LIGHT FIXTURES WITHIN EXISTING CEILING GRID PROVIDE BLOWN -IN INSULATION WITHIN EXISTING DEMISING WALL VIF EXISTING LIGHT FIXTURES ARE INSULATION CONTACT -RATED PROVIDE INSULATION TO EXTENT OF ROOM IN ALL DIRECTIONS SECTION - DEMISING WALL @ BREAK/TOILET ROOM 3/8" = 1'-0" / CARPET PER INTERIOR /' FINISH SCHEDULE / TRANSITION STRIP EXISTING TILE EXISTING SUBFLOOR NOTE: ENSURE THAT CHANGES IN LEVEL OF FLOOR SURFACES NOT TO EXCEED 1/4" PER 2009 ICC A117.1 LEVEL 2 AL 14'-0" BO CEILING AL 9'-1" 7/ LEVEL 1 ,\\ WALL PER FLOOR PLAN J-MOLD TRIM AT TOP OF BASE — SELF COVE BASE FLOORING PER INTERIOR FINISH ROOM SCHEDULE EXISTING SUBFLOOR COVE STICK PERIMETER SUPPORT ANGLE: • THE PERIMETER SUPPORT ANGLE SHALL SUPPLY A SUPPORT LEDGE OF NOT LESS THAN 2" OR MANUFACTURER ASSEMBLY APPROVED FOR USE IN SEISMIC ZONES D, E OR F • MAIN RUNNER OR CROSS RUNNER ENDS, OR BOTH, SHALL BE ATTACHED TO THE PERIMETER ON TWO ADJACENT WALLS. A CLEARANCE OF 3/4" SHALL BE MAINTAINED BETWEEN THE MAIN RUNNER AND CROSS RUNNER ENDS AND THE PERIMETER MEMBERS ON THE TWO OPPOSITE WALLS. ON THE WALLS WHERE THE TERMINAL END RUNNERS ARE NOT FIXED TO THE PERIMETER SUPPORTING CLOSURE, ALLOW FOR 3/4" AXIAL MOVEMENT SUSPENSION WIRE: • MIN 12 GA STEEL WIRE • 8" MAX FROM WALL ON ALL TERMINAL ENDS OF RUNNERS • 4'-0" OC ALONG EACH MAIN RUNNER 1 MAIN RUNNER, SPACING VARIES, TYP CROSS RUNNER, SPACING VARIES, TYP PLAN DIAGRAM ALL CEILING PENETRATIONS (COLUMNS ETC.) AND INDEPENDENTLY SUPPORTED FIXTURES OR SERVICES SHALL BE CONSIDERED AS PERIMETER CLOSURES THAT ALSO MUST ALLOW THE REQUIRED CLEARANCES BY USING SUITABLE CLOSURE DETAIL SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. HORIZONTAL RESTRAINT POINT (SEE DIAGRAM BELOW): • COMPRESSION POST AND BRACING WIRES • 12'-0" OC IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6'-0" FROM EACH WALL BRACING WIRES: • (4)12 GA WIRES ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90° FROM EA OTHER & AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF CEILING. • WIRES ARE TO BE WITHIN 2" OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. COMPRESSION POST PER CEILING SYSTEM MANUFACTURER CROSS RUNNER 4/0$0* // LATERAL FORCE BRACING DIAGRAM HEAVY DUTY MAIN RUNNER CEILING TILE NOTES: 1. SUSPENDED CEILING SYSTEM INSTALLATION SHALL BE INSTALLED PER IBC 2015 (IBC 808 AND IBC 1604.10), ASCE 7-10, AND ASTM E580. 2. THIS DETAIL APPLIES TO SEISMIC DESIGN CATEGORIES D, E, AND F. 3. SPREADER (SPACER) BARS OR OTHER MEANS APPROVED BY THE LOCAL BUILDING DEPT. SHALL BE USED TO PREVENT ENDS OF MAIN BEAMS AT PERIMETER WALLS FROM SPREADING OPEN DURING A SEISMIC EVENT. PERIMETER WIRES SHALL NOT BE USED IN LIEU OF SPREADER BARS. 4. FOR CEILING AREAS EXCEEDING 2,500 SF, A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 SF, EACH WITH A RATIO OF THE LONG TO SHORT DIMENSION LESS THAN OR EQUAL TO 4, SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING PENETRATIONS AND CLOSURE ANGLES OR CHANNELS PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES OR CHANNELS IN ACCORDANCE WITH THE PERIMETER SUPPORT ANGLE DESCRIBED ABOVE AND HORIZONTAL RESTRAINTS OR BRACING. 5. CHANGES IN CEILING PLANE ELEVATION SHALL HAVE INDEPENDENT POSITIVE BRACING. 6. PARTITIONS THAT ARE TIED TO THE CEILING AND ALL PARTITIONS GREATER THAN 6 FEET IN HEIGHT SHALL BE LATERALLY BRACED TO THE STRUCTURE. SUCH BRACING SHALL BE INDEPENDENT OF ANY CEILING LATERAL FORCE BRACING. 7. POWER ACTUATED FASTENERS IN CONCRETE OR STEEL SHALL NOT BE USED FOR SUSTAINED TENSION LOADS OR FOR BRACE APPLICATIONS IN SEISMIC DESIGN CATEGORIES D, E, OR F UNLESS APPROVED FOR SEISMIC LOADING. POWER ACTUATED FASTENERS IN MASONRY ARE NOT PERMITTED UNLESS APPROVED FOR SEISMIC LOADING. A. EXCEPTIONS: a. POWER ACTUATED FASTENERS IN CONCRETE USED FOR SUPPORT OF ACOUSTICAL TILE OR LAY -IN PANEL SUSPENDED CEILING APPLICATIONS AND DISTRIBUTED SYSTEMS WHERE THE SERVICE LOAD ON ANY INDIVIDUAL FASTENER DOES NOT EXCEED 90 LB (400N). b. POWER ACTUATED FASTENERS IN STEEL WHERE THE SERVICE LOAD ON ANY INDIVIDUAL FASTENER DOES NOT EXCEED 250 LB (1,112N). Rc§fergustuLLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM Et W 0 z 0 CD M W z PROJECT # F— LLI W 0 z cc) 00 CO CO C) <>aC —J 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE VE L' 4P LOINS LAI—Si INTERIOR DETAILS RE,„ CITY OF UK7//L o SEP 2 5 2019 SHEET # TYP FLOORING TRANSITION @ CPT / CPT 3" =1'-0" TYP FLOORING TRANSITION @ CPT / LINO 3" = 1'-0" TYP FLOORING TRANSITION @ CPT / RES 3" =1'-0" TYP SELF COVE BASE 3" = 1'-0" DETAIL - ACT SEISMIC BRACING NOT TO SCALE A71.01 TYPICAL CASEWORK NOTES PER TYP CASEWORK NOTES, UNO SCRIBE TO WALL SURFACE BACKSPLASH; MATCH COUNTERTOP MATERIAL, TYP COUNTERTOP MATERIAL PER INTERIOR FINISH LEGEND 9" DIAMETER COUNTERTOP WASTE CHUTE WHERE OCCURS WIRE PULL, TYP UNO CONCEALED HINGES, TYP RECEPTACLE, OFOI __._.___- WHITE MELAMINE INTERIOR, TYP - PLAM FINISH ON ALL EXPOSED SIDES OF DOOR - BASE PER FINISH SCHEDULE — EXTEND FINISHED FLOOR TO WALL; INSTALL BEFORE CASEWORK, TYP A7 PLYWOOD TOE BOX, TYP WASTE CHUTE COUNTERTOP W/ BASE CABINET 1" =1'-0" NOTE: USE MARINE GRADE PLYWOOD / PARTICLE BOARD AT ALL BREAK ROOM CABINETS AND COUNTERTOPS M TYP BUILT-IN COUNTERTOP 3" =1'-0" TO TOP OF SINK RIM PER TYP CASEWORK NOTES, UNO SINK PER SPEC "MIN 3" 11" MIN PLAM FINISH AT TOP & EXPOSED EDGES 3/4" PARTICLE BOARD TOP PLYWOOD DOUBLER ALL AROUND, EXTEND BACK TO WALL. LAMINATE TO PARTICLE BOARD. NOTE: TREAT ALL (4) EDGES OF "SLABS" AS EXPOSED j,. (1-1/2" PLAM EDGE) SCRIBE TO WALL SURFACE BACKSPLASH; MATCH COUNTERTOP MATERIAL, TYP COUNTERTOP MATERIAL PER INTERIOR FINISH LEGEND NON -OPERATIONAL FIXED PANEL WIRE PULL, TYP UNO CONCEALED HINGES, TYP KNEE CLEARANCE PER PER ANSI 117.1 SECTION 306.3 FALSE TOEKICK ATTACHED TO DOOR; HOLD 1/4" AFF FOR PROPER DOOR FUNCTION. PROVIDE BASE PER FINISH SCHEDULE EXTEND FINISHED FLOOR TO WALL; INSTALL BEFORE CASEWORK, TYP ACCESSIBLE SINK BASE CABINET 1" =1'-0" GROMMET PER FLOOR PLAN SCRIBE TO WALL SURFACE EXISTING WINDOW SYSTEM EXISTING EXTERIOR WALL --- POWER OUTLET ACCESS \tk\ TUBE STEEL BRACE, PAINT TO MATCH ADJACENT WALL ANGLE FRONT EDGE -- HOLES FOR FASTENERS @ CONCEALED CONDITIONS, TYP HOLES FOR FASTENERS @ SURFACE MOUNT CONDITIONS, TYP BEVEL BOTTOM EDGE NOTE: • FULLY WELD BRACE ASSEMBLY; GRIND WELDS SMOOTH • PROVIDE BRACE SO NO COUNTER SPAN IS GREATER THAN 3'-6" TYP KNEE BRACE DETAIL NTS io 30" DEEP COU SCRIBE TO WALL SURFACE BACKSPLASH; MATCH COUNTERTOP MATERIAL, TYP - COUNTERTOP MATERIAL PER INTERIOR FINISH LEGEND - NON -OPERATIONAL FIXED PANEL WIRE PULL, TYP UNO - CONCEALED HINGES, TYP KNEE CLEARANCE PER PER ANSI 117.1 SECTION 306.3 FALSE TOEKICK ATTACHED TO DOOR; HOLD 1/4" AFF FOR PROPER DOOR FUNCTION. PROVIDE BASE PER FINISH SCHEDULE EXTEND FINISHED FLOOR TO WALL; INSTALL BEFORE CASEWORK, TYP ACCESSIBLE WORK SURFACE BASE CABINET H = 11 /}" PER TYP CASEWORK NOTES, UNO PER INTERIOR ELEVATIO' 5 T 2" MAX ADJUSTABLE SHELF SCRIBE TO WALL SURFACE BACKSPLASH WHERE OCCURS, MATCH COUNTERTOP MATERIAL, TYP - COUNTERTOP MATERIAL PER INTERIOR FINISH LEGEND WIRE PULL, TYP UNO 3/4" WHITE MELAMINE ADJUSTABLE SHELF, TYP WHITE MELAMINE INTERIOR, TYP PLAM FINISH ON ALL EXPOSED SIDES OF DOOR CONCEALED HINGES, TYP -- BASE PER FINISH SCHEDULE EXTEND FINISHED FLOOR TO WALL; INSTALL BEFORE CASEWORK, TYP PLYWOOD TOE BOX, TYP 1. FIELD -VERIFY DIMENSIONS OF EXISTING CONDITIONS WHERE CASEWORK WILL BE INSTALLED PRIOR TO FABRICATION. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK. 2. REFER TO INTERIOR FINISH LEGEND FOR FINISHES WHERE NOTED IN ELEVATIONS. 3. REFER TO ELECTRICAL AND MECHANICAL DRAWINGS FOR SYSTEMS NOT SHOWN, 4. WHERE A 2'-10" SINK COUNTER HEIGHT IS SPECIFIED. THE 2'-10" DIMENSION IS TO THE TOP OF THE COUNTER OR THE TOP OF THE SINK RIM, WHICHEVER IS HIGHER. 5. PROVIDE FINISHED ENDS AT ALL EXPOSED CASEWORK SURFACES, TYP UNO. 6. ALL BASE CABINETS = 24" DEPTH TO FACE OF BOX, TYP UNO. 7. ALL UPPER CABINETS = 14" DEPTH TO FACE OF BOX, TYP UNO. 8. ALL FULL -HEIGHT CABINETS = PER DETAIL - / 9. ALL COUNTERTOPS = 251/4" DEPTH FROM FINISH FACE OF WALL, TYP UNO. 10. ALL BACKSPLASHES TO BE FINISHED SAME AS COUNTERTOP, TYP UNO. 11. ALL CONDITIONS ILLUSTRATED BELOW ARE TYPICAL UNO. 12. ALL SHELVES AND DIVIDERS ARE ADJUSTABLE, TYP UNO. 13. ALL EXPOSED PLUMBING TO BE INSULATED. IOR ELEVATIONS z' r L� li LU PER TYP CASEWORK NOTES, UNO 2" DIAMETER PLASTIC GROMMET WHERE OCCURS: COORDINATE LOCATION WITH COUNTERTOP KNEE BRACE 4" - COUNTERTOP MATERIAL PER INTERIOR FINISH LEGEND -- CABLE TRAY (BASIS OF DESIGN: MOCKETT, WM4 "G- SHAPED WIRE MANAGER", COLOR: TBD.) 1 1/2" x 1/8" SQ TUBE STEEL BRACE; INSTALL BRACE WHERE INDICATED AND @ 42" MAX SPACING AT ALL OPEN COUNTERTOPS. PAINT TO MATCH ADJACENT WALL AT SURFACE MOUNT CONDITIONS. SEE KNEE BRACE DETAIL 7 / A71.02 -- 3/8" DIA FASTENERS, TYP FINISHED FLOOR TYP COPY / WORK ROOM COUNTERTOP 1" =1'-0" PER TYP CASEWORK NOTES, UNO rn 0} -J � I X a% TYP UPPER CABINET 1" = 1-0" PER TYP CASEWORK NOTES, UNO FINISHED CEILING PER RCP PLAM FINISH ON ALL EXPOSED SIDES OF DOOR WHITE MELAMINE INTERIOR, TYP 3/4" WHITE MELAMINE ADJUSTABLE SHELF, TYP CONCEALED HINGES, TYP - WIRE PULL, TYP UNO /4" VALANCE. MATCH PLAM FINISH z 0 i= al' ADJUSTABLE SHELF SCRIBE TO WALL SURFACE BACKSPLASH WHERE OCCURS, MATCH COUNTERTOP MATERIAL, TYP COUNTERTOP MATERIAL PER N INTERIOR FINISH LEGEND -� WIRE PULL, TYP UNO CONCEALED HINGES, TYP 3/4" WHITE MELAMINE ADJUSTABLE SHELF, TYP WHITE MELAMINE INTERIOR, TYP PLAM FINISH ON ALL EXPOSED SIDES OF DOOR BASE PER FINISH SCHEDULE EXTEND FINISHED FLOOR TO WALL; INSTALL BEFORE CASEWORK. TYP R�ergusmiLLER ARCHITECTURE INTERIORS PLANNING VIZLAB 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM v J w a) Q Q CL W J 0 0 Z Y Qcp 0 CO 2017036.20 PERMIT SET ISSUE DATE SEPTEMBER 12, 2019 REVISION SCHEDULE CASEWORK DETAILS CIR`' OF TUKWILA SEP-_-5 2019 — P COUNTERTOP BACKSPLASH @ SILL 1/2" =1'-0" A71.01 TYP BASE CABINET W/ 1-DRAWER " =1'-0" A71.01 TYP BASE CABINET W/ DOOR " =1 `-0" PLYWOOD TOE BOX, TYP SHEET # A71.02