HomeMy WebLinkAboutPermit D19-0310 - MACY'S - BASEMENT, CHILDREN'S DRESSING AREA AND OFFICE AREA WITH NEW DOORMACY'S 500 SOUTHCENTER MALL AP N : 3597000246 EXPIRED 06/14/2021 D19-0310 Parcel No: Address: 0 ��^�xx � ^U ~~�^� ��o Tukwila Department of Community Development 630O8outhcerterBoulevard, Suite #10U Tukwila, Washington 981A8 Phnne:206-432'367O Inspection Request Line: 2Q0-43Q'g350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3597000246 Permit Number: D19-0310 Project Name: MACY'S Issue Date: 11/26/2019 Permit Expires On: 5/24/2020 Owner: Contact Person: Name: Contractor: Address: License No: Lender: FEDERATED DEPT STORES INC 7VV7THSTATTN: TAX DEPARTMENT -SHF,C|NONNAT|,WA, 45302 ER|[KO[H O]O3lSQTHAVE NE, STsZSD' REDMOND, WA, 9885Z Phone: (425)636-8006 THE S[|CONSTRUCTION GROUP INC Phone: (646) 789-4564 Z6'lOSK|LLMANAVE, LONG ISLAND CITY, NY, 11101 AE[3996 Expiration Date: EOO5OUTM[ENTERMALL, TUKVV|U\ VVA,98l88 DESCRIPTION OF WORK: BASEMENT ' CONSTRUCT NEW FITTING ROOM FOR INTIMATE APPAREL. BASEMENT MODIFY DOORS |NTHE CHILDRENS DRESSING AREA. 3RD FLOOR - INSTALL NEW FURRING ON PERIMETER WALLS, WING WALLS, REMOVE FITTING ROOMS AND CHANGE INTO OFFICE AREA WITH NEW DOOR. Project Valuation: $75/000.00 Type ofFire Protection: Sprinklers: YES Fire Alarm: Type nfConstruction: 118 Electrical Service Provided by. TUKWILA Fees Collected: $2'255D7 Occupancy per IBC: M Water District: TUKVV|LA Sewer District: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[Z96-468: VVAState Energy Code: 2017 2017 Public Works Activities: Chonne|ization/SthpinQ: [u/b[ut/Access/5dewa|k: Fire Loop Hydrant: Flood Control Zone: Hau|inQ/Overs|zeLnad: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: O Fill: U Number: O Permit Center Authorized Signature: IDae: |headycertify that | have read an dthispennbandknmwthesametnbetrueandcnrnsL All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting ofth� � me���a�mh��v�|a���noe|the po�do��any n�er �oteorlocal |aw� �ruoUonnrthe pe�ormanceofvvork. |amauthohzedtosign and obtain this development �o�he��ndhinnoa�a i� , ' - Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance,or if the work issuspended orabandoned for aperiod ofl8Odays from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT COND0ONS*** Z: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. AS[E7,Chapter 13. 5: Partition walls shall not betied tuasuspended ceiling grid. All partitions greater than Ofeet inheight shall belaterally braced tothe building structure. Such bracing shall beindependent ofany ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed inthe State ofWashington, Periodic special inspection isrequired during anchorage ofstorage racks 8feet urgreater inheight. g: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit: issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3,5 feet (1067 mm) above the floor, The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1018.1) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #2437) �� 26: Fire protection systemsumx be maintained in accordance with the oriOinw,nxtaUadon standards for that »yotem. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled oradded to. Alterations tnfire protection systems shall bedone inaccordance with applicable standards. (|FC9UI.4) 27: Afire alarm system is required for this project. The fire alarm system shall meet the requirements of NfP.A.7Zand City Ordinance #Z437. 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. Nowork shall commence until afire department permit has been obtained. (City Ordinance #Z437)(iF[9012) 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth inTable No. 80J.1lnfthe International Building Code. 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 33: These plans were reviewed byInspector 511. |fyou have any questions, please call Tukwila Fire Prevention Bureau at(ZOG}57S4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (3D6)438'9350 1700 BU|L0NGF|NAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 03/0 Project No, Date Application Accepted: q tq Date Application Expires: 3 - c;s -Do (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail. **Please Print** SITE INFORMATION King Co Assessor's Tax No.: 359700-0246 500 Southcenter Mall Site Address: Suite Number: Tenant Name: Macys PROPERTY OWNER Name: Macys, Chris Oconnell Address: 500 Southcenter Mall City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Eric Koch, Partners Architectural Design Group, Address: 8383 158th Ave NE, Suite 250 City: Redmond State: WA Zip: 98052 Phone: 425-636-8006 x 105 Email: Eric@padgi.com DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE Name: Eric Koch, Partners Architectural Design Group, Address: 8383 158th Ave NE, Suite 250 City: Redmond State: WA Zip: 98052 Phone: 425-636-8006 x 105 Email: Eric@padgi.com GENERAL CONTRACTOR INFORMATION Company Name: ,. to be det. Address: City: State: Zip: Phone: St Contr Reg No.: Exp Date: Tukwila Business License No.: Floor: Bsmt / 3rd New Tenant: . Yes El ..No ARCHITECT OF RECORD Company Name: Partners Architectural Design Group, Inc. Address: 8383 158th Ave NE, Suite 250 City: Redmond state: WA Zip: 98052 Phone: 425-636-8006 x 105 Email: Eric@padgi.com ENGINEER OF RECORD Company Name: n/a Address: City: State: Zip: Phone: Email: LENDER — WHO IS FUNDING THE PROJECT (required for projects $5,000 or greater per RCW 19.27.095) Name: 44/..a- tyt Actt t Address: co 50144 ,...)...41. ps. LA_ City: en jy.....tdi LA State: L4 kr_ Zip:9 1&& MONTHLY SERVICE BILLING -or- WATER METER REFUND/BILLING Name: Macys, Chris Oconinell Address: 500 Southcenter Mall City: Tukwila State: WA Zip: 98188 Phone: 650-341-3333 x 4128 WAPermit Center (Rachelle)\Applications \Word \ Construction Permit Application Revised 6-2019,docx Revised: June 2019 Page 1 of 3 BUILDING DIVISION INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 75,000.00 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Basement - construct new fitting room for intimate apparel Basement - modify doors in the childrens dressing area. 3rd Floor - install new furring on perimeter walls, wing walls remove fitting rooms and change into office area with new door. Will there be new rack storage? LJ.. Yes E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor no II E3 Mercantile 2nd Floor no II E3 Mercantile 3rd Floor 6,800 s.f. no II E3 Mercantile Floors thru 259,377 s.f. Basement 635 s.f. no II E3 Mercantile Accessory Structure* Garage 0 Attached 1::] Detached Carport II Attached 0 Detached Covered Deck Uncovered Deck PLANNING DIVISION INFORMATION — 206-431-3670 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: No Exterior Work Lot Area (sq ft): Floor area of principal dwelling: Floor arca of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS — 206-575-4407 Sprinklers 0 Automatic Fire Alarm 0 None ▪ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Ej Yes EJ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. PUBLIC WORKS INFORMATION — 206-433-0179 O ...Permanent Water Meter Size (1) . " WO # (2) " WO # (3) " WO # O ...Temporary Water Meter Size (1). " WO # (2) " WO # (3) " WO # 0 ...Water Only Meter Size " WO # 0 Deduct Water Meter Private C1 Ej ...Sewer Main Extension Public CI 0 ...Water Main Extension Public 0 Private Ej No Change W: \Permit Center (Rachelle)\Applications \ Word \ Construction Permit Application Revised 6-2019.dooc Revised: June 2019 Page 2 of 3 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 9/24/2019 Print Name: Eric Koch Day Telephone: 425-636-8006 x 105 Mailing Address: 8383 158th Ave NE, Suite 250, Redmond, WA 98052 City State Zip WAPermit Center (Rachelle)\ Applications \ Word \Construction Permit Application Revised 6-2019.docs Revised: June 2019 Page 3 of 3 DESCRIPTIONS PermitTRAK ACCOUNT QUAN ITY PAID 1,402.68 D19-0310 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $1,402.68 Credit Card Fee $40.85 Credit Card Fee R000.369.908.00.00 0.00 $40.85 DEVELOPMENT $1,298.17 PERMIT FEE R000.322.100.00.00 0.00 $1,273.17 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25,00 TECHNOLOGY FEE $63.66 TECHNOLOGY FEE R000.322.900.04.00 0.00 $63.66 TOTAL:FEES PAID BY RECEIPT: R19166 $1,402..68 Date Paid: Tuesday, November 26, 2019 Paid By: STEVEN SHANKMAN Pay Method: CREDIT CARD 01833G Printed: Tuesday, November 26, 2019 12:38 PM 1 of 1 SYSTEMS CO TVKWILA ETK4KIT 0288 SOUTH[ENTEn BLVD TUKWILA' WA 98188 286'433-1870 CITY OF TUKWILA 8017340000802374464580 Date: 11/I6/2019 12:37:27 PM CREDIT CARD SALE VISA CARD NUMBER: * TRAN AMOUNT: $1,402.68 APPROVAL [D: 01833G RECORD #: 000 [Lsno ID: frankie X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL xMnVwT ACCORDING TO THE [4K0 ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy • Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $852.39 D19-0310 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $85 . 9 Credit Card Fee $24.83 Credit Card Fee R000.369.908.00.00 0.00 $24.83 DEVELOPMENT $827.56 PLAN CHECK FEE R000.345.830.00 00 0.00 $827.56 TOTAL FEES PAID BY RECEIPT: R18668 , $852.39 Date Paid: Wednesday, September 25, 2019 Paid By: ERIC KOCH Pay Method: CREDIT CARD 80727G Printed: Wednesday, September 25, 2019 11:07 1 of 1 AM Y5TEM5 CO TUKWIL4 ETR4KIT 6288 S0UTHCENTEK 8LVD TUKWILA, WA 94188 200'433-1870 CITY OF TUKWILA 0817340000882374464580 Date: 09/25/2019 I1:06:43 AM CREDIT CARD SALE VISA CARD NUMBER: TRAN AMOUNT: $852.39 APPROVAL [D: 80727G RECORD #: 000 cLsnx ID: kandace X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr t Type 0f' Ins ection: Ad Tess Date Cal ed: Specia Instructions, Date Wanted: a.rn. Requester: P one N'''�' ElApproved per applicable codes. Corrections required pri 0 proval. COMMENTS: nspecto Da REINSPECTION FEE REQUIRED. Prior to next inspection. te'e must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. NSP ION NO. INSPECTION RECORD Retain a copy with permit DIl 310 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 Pro' +: r �j-G Type f Insp+ cion: Address:.:/ Elate Called: Special Instructions: , Date Warted: a.cn. Reque 1 Z 3 �� Phone Na: Approved per applicable codes. Corrections required prior to approval. CENTS: nspecto Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter 6Ivd.. Suite 100. Catt to schedute reinspection. P:RMff CYTRO PCPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0310 DATE: 10/01/2019 PROJECT NAME: MACY'S SITE ADDRESS: 500 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division w,Y\W or s 4+1 /Mc/ 10:1;q1 ib4 Fire Prevention up Planning bivision Structural Li Permit Coordinator PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 10/01/19 Structural Review Required REVIEWER'S TIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DA I E: 10/29/2019 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire D Ping 0 PW 0 Staff Initials: 12/18/2013 kalLabw & Industries (httpswinimaxiov) Contractors THE SCI CONSTRUCTION GROUP INC Owner or tradesperson Principals CATALANO, CHRISTOPHER J, PRESIDENT Doing business as THE SCI CONSTRUCTION GROUP INC VVA UBI No, 604 355 844 26-16 SKILLMAN AVE LONG ISLAND CITY, NY 11101 646-789-4564 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. SCICOSC818D7 Effective — expiration 03/22/2019-03122/2021 Bond Travelers Cas and Surety Co of America Bond account no. 107062161 $12,000.00 Received by 1..61 Effective date 03/22/2019 03/19/2019 Expiration date Until Canceled Insurance Transportation Ins Co $1,000,000.00 Policy no. 6057349267 Received by L&I Effective date 03/22/2019 02/1512019 Expiration date 02/15/2020 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Not allowed to have apprentices. M A O H CEN T R TUvNW LA, WA 90'0 us PERMIT U:MITTAL CURRENT CODES V � (`=� � N � T Y M NP )' 2015 INTEi�ATIONAL BUILDING CODE 2015 NTERRNATIONAL EXISTING BUILDING CODE 2015 WASHINGTON STATE ENERGY CODES 2009 ICC AI11.1 BARRIER -FREE STANDARD 2015 INTERNATIONAL FIRE CODE 2011 NATIONAL ELECTRIC CODE 2015 UNIFORM PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE ICON'ULTANTS INTERURBAN ADD TO SEATTLE POR OF SW 1/4 OF SE 1/4 OF SEC 23 & OF SE 1/4 OF SW 1/4 OF SEC 23 & OF INTERURBAN ADD TO SEATTLE & OF BROOKVALE GARDEN TRACTS & OF W H GILLIAM DONATION LAND CLAIM NO 40 - BEG SW COR OF SW 1/4 OF SE 1/4 OF SEC 23 TH N 89-40-24 W 217 FT TH N 0-19-36 E 150 FT TH S 89-40-24 E 151.60 FT TO TPOB TH N 0-19-36 E 72 FT TH S 89-40-24 E 406.80 FT TH S 0-19-36 W 196 FT TH N 89-40-24 W 10.50 FT TH S 0-19-36 W TO 5 MGN OF SW 114 OF SE 114 OF SEC 23-23-04 TH WLY ALG SD S MGN TAP S 0-19-36 W OF TPOB TH N 0-19-36 E TO TPOB TAX ACCOUNT NUMBER 35'3100-024to OWNER: MACY'S NORTHWEST CONTRACTOR 400 BELLEVUE SQUARE THE 5CI CONSTRUCTION GROUP BELLEVUE, WA 98004 26-16 SKILLMAN AVE. SUITE B PH: (650) 341-3333 EXT 4125 LONG ISLAND CITY, NY 11101 E-MAIL:CHRISTOPHERJDCONNELLeMACYS.COM PH: (631) 628-0219 CONTACT: CHRIS O'CONNELL E-MAIL: 55HANKMANOSCI.GROUP CONTACT: STEEE SHANKMAN ARCHITECT / PLANNER: PARTNERS ARCHITECTURAL DESIGN GROUP, INC. 8383 158TH AVE NE, SUITE 250 REDMOND, WA J8052 PH: (425) 636-6006 E-MAIL: ERICmPADGI.COM CONTACT: ERIC KOCH SITE LOCATION E --"-o 0 L ES RM C�y ED a flj = 101 N41 J I N r m-- M' AE10D)BR 0_EViAT�0N`r--_-_-"I ALL CONSTRUCTION SHALL CONFORM TO THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THESE PLANS 4 PROJECT SPECIFICATIONS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETWEEN THE PLANS 4 SPECIFICATIONS, NOTIFY THE. ARCHITECT IMMEDIATELY. FINISH FLOOR REF. DATUM EQUALS (100'-0') REFER TO TOPOGRAPHIC SURVEY FOR ACTUAL SITE ELEVATION. ALL DIMENSIONS ARE TO FACE OF CONCRETE, MASONRY, FACE OF FRAMING OR COLUMN CENTER LINES U.N.O. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD PRESSURE TREATED WOOD OF ANY SPECIES OR FOUNDATION GRADE CEDAR OR REDWOOD. ALL MARKED BY AN APPROVED TESTING AGENCY. ALL WOOD FORMS USED FOR CONCRETE, IN THE GROUND OR BETWEEN FOUNDATION SILLS 4 THE GROUND SHALL BE REMOVED. PROVIDE HORIZONTAL FIREBLOCKiNG IN ALL FRAME WALLS AT 10'-0' O.C. 4 WHERE FRAME WALLS PENETRATE CEILING. FIREBLOCK IN ACCORDANCE WITH I.B.C. SEC. 118.2. DRAFTSTOPPING IN FLOORS IS NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH SPRINKLER SYSTEMS IN ACCORDANCE WITH SECTION 9033.E (IBC'71333) DRAFTSTOPPING IN ATTICS IS NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9033.1. (IBC 116.43) PROVIDE A FLOOR OR LANDING NOT GREATER THAN i4' BELOW THRESHOLD AT ALL DOORWAYS. PROVIDE BLDG. ADDRESS PER OWNERS BUILDING STANDARDS, EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. IBC 1010.1.9.1 HARDWARE, DOOR HANDLES, ULLS LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER Il SHALL NOT REQUIRED RIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. 1010.1.93 LOCKS AND LATCHES. LOCKS AND LATCHES SHALL BE PERMITTED TO PREVENT OPERATION OF DOOR5 WHERE ANY OF THE FOLLOWING EXISTS: 2. IN BUILDINGS IN OCCUPANCY GROUPS M, THE MAIN EXTERIOR DOOR OR DOOR5 ARE PERMITTED TO BE EQUIPPED WITH KEY -OPERATED LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: 2.1 THE LOCKING DEVICE 15 READILY DISTINGUISHABLE AS LOCKED, 22 A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE SIGN SHALL BE IN LETTERS I INCH HIGH ON A CONTRASTING BACKGROUND. ALL ROOMS OR AREAS HAVING AN OCCUPANT LOAD OF 50 (1,500 SF OF RETAIL SPACE) OR MORE SHALL HAVE AT LEAST 2 EXITS TO THE EXTERIOR OR TO AN EXIT PASSAGEWAY ( ONE -HOUR CONSTRUCTION). ( I.B.G. 10243 ) EXITS SHALL HAVE A MIN. SEPARATION OF ONE HALF THE MAX. OVERALL DIAGONAL OF THE BUILDING OR AREA SERVED, MEASURED IN A STRAIGHT LINE BETWEEN EXITS. ( I.B.G. SECTION 1001.1.1 ) EXCEPTION 2 - WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9033.1 OR 9033.12, THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. EXPOSED INSULATION MATERIALS INCLUDING FACINGS AND VAPOR BARRIERS, SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25, AND A SMOKE DENSITY NOT TO EXCEED 450, OR SHALL BE IN SUBSTANTIAL CONTACT WITH THE WALL OR CEILING SURFACE FINISH. (I.B.C. SECTION 1203) ELECTRIC RESISTANCE HEAT 15 NOT ALLOWED UNLESS THE WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE COMPLIANCE FORM IS REVISED. WHEN THE FLOOR AREA OF 'GROUP B OR GROUP M' OCCUPANCIES EXCEED 3000 SF., TWO BARRIER FREE RESTROOMS WILL BE REQUIRED. 29022 EXC. 3 WASHINGTON STATE AMENDMENTS. BUILDING SECTION 1 SECTION IDENTIFICATION '�'-2 LOCATED ON SHEET_ WALL SECTION r2 SECTION IDENTIFICATION A-2 E LOCATED ON SHEET - DETAIL 3 DETAIL IDENTIFICATION A-5 LOCATED ON SHEET INTERIOR ELEVATION 2 ELEVATION IDENTIFICATION `�-� LOCATED ON SHEET ROOM SYMBOL OFFICE <ROOM NAME 101 ROOM NUMBER ES 1A2 lest No FLoofeI�BASE g i _ u 2nd No WALLSNUAINSCOT 3rd No CEILING 990FI�—CEILING HEIGHT SQUARE FOOTAGE GRID MARKERS A LETTERS IN ONE DIRECTION 1 NUMBERS IN THE OTHER DOOR SYMBOL OE DOOR NUMBER WALL SYMBOL O�_WALL IDENTIFICATION WINDOW! SYMBOL zLE WNDOW IDENTIFICATION MATCH LINE SHADED PORTION IS THE SIDE CONSIDERED t AND Ea EQUAL O.C. ON CENTER O L ANGLE ET.. EQUIPMENT O/ OVER NORTH ARROW a A7 EXIST. EXISTING OPP. OPPOSITE D CENTERLINE EXPO. EXPOSED DIAMETER OR EXT. EXTERIOR PL. PLATE ROUND FA.I.C. FURNISHED BY OWNER PLYWD. PLYWOOD -L PERPENDICULAR INSTALLED BY CONT'R. P.P. POWER POLE • POUND OR NUMBER F.D. FLOOR DRAIN PLAM PLASTIC LAMINATE AB. ANCHOR BOLT F.E. FIRE EXTING- £LEVATION MARKER ACT ACOUSTICAL CEILING TILE UISHER R. RADIUS OR R15ER APP. ABOVE FINISH FLR F.H• FIRE HYDRANT R I. ROOF DRAIN AGGR AGGREGATE FIN. FINISH REC. RECOMMENDED ALUM. ALUMINUM FLASH. FLASHING PER REFERENCE FINISH GRADE ELEVATION ANOD. ANODIZED FLR FLOOR REINF. REINFORCED Al APPROX. APPROXIMATE FLUOR FLUORESCENT REQ'D. REQUIRED ARCH. ARCHITECTURAL FOUND. FOUNDATION RM. ROOM ASPH. ASPHALT FRM'G. FRAMING �ry TOP OF CURB FT. FOOT OR FEET S. SOUTH BD. BOARD FTG. FOOTING S.C. SOLID CORE BLDG. BUILDING FURR FURRING SCHED. SCHEDULE BLK. BLOCK GA GAUGE SHT. SHEET TOP OF PAVEMENT BLK'G. BLOCKING GALV GALVANIZED SHT'G. SHEATHING 4� BM. BEAM GJC. GENERAL CONTRACTOR SIM. SIMILAR BOT. BOTTOM GL. GLASS SPEC. SPECIFICATIONS B.U.R BUILT UP ROOF GNP. GROUND 80. SQUARE GR. GRADE STD. STANDARD CAB. CABINET GP. GROUP STL. STEEL G.B. CATCH BASIN G.W.B. GYPSUM WALL STOR. STORAGE — CENTER LINE GEM. CEMENT BOARD STRUC. STRUCTURAL CH. CHANNEL GYP. GYPSUM SUSP. SUSPENDED O.J. CONTROL JOINT 8.4 V. STAIN AND VARNISH -- PROPERTY LINE CLG. CEILING HDWR HARDWARE SVC. SERVICE CLR. CLEAR HDCR HANDICAP SYM. SYMMETRICAL CA. CLEAN OUT HDWD. HARDWOOD SAU 51DELUALK > >> CENTER LINE OF STREAM COL. COLUMN H.B. HOSE BIBS CONC. CONCRETE H.G. HOLLOW CORE T. TREAD CONN. CONNECTION HUM. HOLLOW METAL T.G. TOP OF CURB CONSTR. CONSTRUCTION WORM • HORIZONTAL TEL. TELEPHONE CONT. CONTINUOUS HR. HOUR TA G. TONGUE AND GROOVE C.T. CERAMIC TILE HT. HEIGHT THK. THICK NEW CONTOUR CTR CENTER TA.P. TOP OF PLATE CTSK COUNTER SUNK INST. INSTALLATION T.P. TOP OF PAVEMENT �18 INSUL. INSULATION T.W. TOP OF WALL DBL. DOUBLE INT. INTERIOR TYR TYPICAL / DEPT. DEPARTMENT / EXISTING CONTOUR DET. DETAIL LAM. LAMINATED U,B.C. UNIFORM BUILDING —19 DIA DIAMETER I.S. POUND CODE / DIM. DIMENSION LOC. LOCATION UNF. UNFINISHED DN DOWN UAN. UNLESS OTHERWISE DR DOOR MATL. MATERIAL NOTED D.S. DOUNSPOUT MAX MAXIMUM REVISION CLOUD DWG. DRAWING MFR. MANUFACTURER VERT. VERTICAL MUD. MANHOLE IDENTIFYING NUMBER E. FAST MECH. MECHANICAL W. WEST e EA EACH MIN. MINIMUM W/ WITH E.IF.S. EXTERIOR INSULATION MISC. MISCELLANEOUS WD. WOOD FINISH SYSTEM MTD. MOUNTED WDW. WINDOW E.J. EXPANSION JOINT MTL. METAL W/O WITHOUT EL. ELEVATION W.P. WATERPROOF ELEC. ELECTRICAL N. NORTH W.R. WATER RESISTANT ELEV. ELEVATOR N.I.C. NOT IN CONTRACT UBCT. WAINSCOT ENCL. ENCLOSURE NO. NUMBER WT. WEIGHT E.P. ELECTRICAL PANEL N.T.S. NOT TO SCALE TTLE NDEX ARCHITECTURAL A-0.1 COVER SHEET A-02 ADA DETAILS A-2.1 DEMO PLAN / FLOOR PLAN / FITTING ROOMS - BASEMENT LEVEL A-22 DEMO PLAN - FURNITURE - 3RD FLOOR A-23 FLOOR PLAN - FURNITURE - 3RD FLOOR A-2.4 REFLECTED CEILING PLAN - FURNITURE 3RD FLOOR SEPARA4TTTE PeaEnr RMIT RE 'RE FOR: rL�Y,dJ Eiectrirsl ye�Plumbing [� Gas Piping BUILDING DIVISION WS IM 04 1 MM rK OEM INTERIOR TENANT IMPROVEMENT FOR THE FOLLOWING STORE DEPARTMENTS: 3RD FLOOR FURNITURE DEPARTMENT. MODIFY PERIMETER SHELVING BY REMOVING VERTICAL PARTITIONS, INSTALLING NEW FURRING WALLS, REPAIR SOFFIT LIGHTING AND INSTALL NEW OUTLETS AND PENDENT LIGHTS. NEW FITTING ROOMS FOR INTIMATE APPAREL DEPARTMENT IN AN EXISTING STORAGE ROOM. MODIFY CHILDRENS FITTING ROOM DOORS. ALL WORK TO BE INSTALLED PER PLANS. REVISIONS No Sial! ,t- `,IiJe to lne scope of Work wtlnoU1 W o' ? ?rOval oI the Tukwila Budduig C'­s,on. NOTE: Rewsi6ns will require a new plan submittal and may include additional plan review. LOCATION: 500 SOUTHCEINTER MALL ZONING: TUC -RC OCCUPANCY: M (MERCANTILE) NO CHANGE PROPOSED NUMBER OF STORIES: 3 PLUS BASEMENT CONSTRUCTION TYPE: TYPE LIB - FULLY SPRINKLED SPRINKLER SYSTEM: EXISTING FULLY SPRINKLED - NO CHANGES ANTICIPATED MECHANICAL SYSTEM: EXISTING SYSTEM - NO MODIFICATIONS PROPOSED ELECTRICAL SYSTEM: EXISTING SYSTEM - NO MODIFICATIONS PROPOSED STRUCTURAL: NO STRUCTURAL WORf< BUILDING AREA: (NO CHANGE TO EXISTING) AREA OF IMPROVEMENT: FURNITURE 3RD FLOOR ro'000 S.F. INTIMATE APPAREL / CHILDRZENS FITTING ROOMS 635 S.F. TOTAL: -1,435 S.F. WALL AND OPENING PROTECTION. TYPE IIA FULLY SPRINKLED (IBC) IBC TABLE 601 STRUCTURAL FRAME: M, SI: (COL'S, GIRDERS, TRUSSES) 0 HOUR BEARING WALLS - EXTERIOR: (IBC 602) 2 HR LESS THAN 5 FEET I HR LESS THAN 10 FEET I HR LESS THAN 30 FEET 0 HR GREATER THAN 30 FEET BEARING WALLS INTERIOR.- 0 HOUR NON BEARING WALLS - EXTERIOR (IBC 602) 2 HR LESS THAN 5 FEET I HR LESS THAN 10 FEET 0 HR LESS THAN 30 FEET 0 HR GREATER THAN 30 FEET NON BEARING WALLS INTERIOR: NO RATING FLOOR: 0 HOUR ROOF: 0 HOUR SHAFT ENCLOSURES: I HR - SEE 113 FOR EXCEPTIONS LESS THAN 4 STORIES STORAGE RACKS: PER IBC 413.1 4 IFC 3201 NOT TO EXCEED M FEET IN HEIGHT MERCHANDISE NOT TO EXCEED 12'-0' FIL P®em14 No.o. Plan review approval is omissions. Approval of co not authorve the v is ordinance Rece� i ac Fri CODE COMPLIA APPROVED OCT 312019 City d# Tukwia BUILDING DIVIS RECEIVED CITY OF TUKWILA SEP 2 5 2019 PERIMIT CENTER a does_ le or and s2o� REGISTERED ARCHITECT ERIC E KOCN STATE OF 'il"TON , 4 O 0 m a N U to � Q m C v W DRAWN: EEK. CHECK:_ EEK JOB NO: i9-023 ff J-1-L z W 14 UT ifs i-i-{ tzu 01 0 W SHEET: 0� �I WHEN THE OCCUPANT LOAD EXCEEDS 49 THE DOORS MUST SWING IN THE DIRECTION OF EXIT TRAVEL. IBC 1010.12.1 SEPARATE APPROVALS AND PERMITS REQUIRED FOR ELECTRICAL a OF: — SHEETS F APPROACH -1 I -APPROACH -I 1 2" MAX. CH ACCESSIBLE DRESSING ROOMS F AI'P, R°AC� ,H , Z '�- APPROA 12^ � � 32" 302 FLOOR SURFACES F APPROACH -I z ( 1 I I ( MIN. I I MIN. 302.1 GENERAL. FLOOR SURFACES SHALL 803 DRESSING, FITTING, AND LOCKER ROOMS I I � I 1 ( I z I ( BE STABLE, FIRM AND SLIP RESISTANT AND SHALL COMPLY WITH SECTION 302. CLEAR FLOOR SPACE NOTES: I 1 o I MN. 1 " %„ ,;;,,' ,1;. CHANGES IN LEVEL IN FLOOR SURFACES 803.1 GENERAL. ACCESSIBLE DRESSING, FITTING, AND 1. DOORS SHALL BE PERMITTED TO SWING INTO TURNING SPACES (304.4) uI I I 1 A�183 90 SHALL COMPLY WITH SECTION 303. LOCKER ROOMS SHALL COMPLY WITH SECTION 803. 2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE MUST I I Fig. 302.2 302.2 CARPET. CARPET OR CARPET TILE 803.2 TURNING SPACE. A TURNING SPACE COMPLYING ADJOIN AN ACCESSIBLE ROUTE OR ANOTHER CLEAR FLOOR SPACE I I SHALL BE SECURELY ATTACHED AND CARPET PILE THICKNESS WITH SECTION 304 SHALL BE PROVIDED WITHIN THE ROOM. {305.6} (°) SHALL HAVE A FIRM CUSHION, PAD OR 3. A CLEAR FLOOR SPACE IS REQUIRED AT ANY DEVICE WITH HINGED DOOR BACKING OR NO CUSHION OR PAD. 803.3 DOOR SWING. DOORS SHALL NOT SWING INTO THE AN OPERABLE PART (309.2) FRONT APPROACH FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE FRONT APPROACH, PUSH SIDE; PULL SIDE LEVEL LOOP, CARPET OR TEXTURED LOOP,ARPET TILE LLEVELE A ROOM UNLESS A CLEAR FLOOR SPACE COMPLYING WITH DOOR w BOTH CLOSER & LATCH SECTION OF E PROVIDED WITHIN THE ROOM, BEYOND 1 " 36" 12" / 32^ CUT PILE, OR LEVEL LCUT/UNCUT PILE THE ARC OF THE DOOR SWING. MIN. MINK MIN. I APPROACH I MIN. TEXTURE, THE PILE SHALL BE 1/2 INCH I I Z z ED ES) FACIMUM ARPETNSHALLHT. EXPOSED 803.4 BENCHES. A BENCH BE FASTENED SHALL BE PROVIDED WITHINTHEROOMN� SECTION 903 z r �' X < 36" - - - - - - - - - - `o I I I 0O 1 (b•) TO THE FLOOR AND SHALL HAVE TRIM 22" ca ( A I SLIDING DOOR I z I z_ MIN. I I x I ALONG THE ENTIRE LENGTH OF THE 803.5 COAT HOOKS AND SHELVES. ACCESSIBLE COAT J F - - - EXPOSED EDGE. CARPET EDGE TRIM HOOKS PROVIDED WITHIN THE ROOM SHALL ACCOMMODATE (� I SHALL COMPLY WITH SECTION 303. A FORWARD REACH OR SIDE REACH COMPLYING NTH f- z // fff/// ,a If�� 1 § �j'\ t0 1<r 32" SECTION 368. WHERE PROVIDED, A SHELF SHALL BE 40 ' 6 I I 5 36 I ° 42 (� MIN. INCHES (1015 MM) MINIMUM AND 48 INCHES (1220 MM) I� �i d 1 1 ( IdVE141 MAXIMUM ABOVE THE FLOOR. MIN. 60 (b•) (d.) (e.) (f.) (b.) FOLDING) DOOR 903 BENCHES SIDE APPROACH HINGE APPROACH, PULL SIDE HINGE APPROACH, PULL SIDE HINGE APPROACH, PUSH SIDE PUSH SIDE ` 1 2" Fig. 304.3.2 Ref. 304.3.1 903.1 GENERAL ACCESSIBLE BENCHES SHALL COMPLY WITH T-SHAPED SPACE CIRCULAR SPACE F APPROACH -- CLEAR WIDTH OF DOORWAYS 2 MAX. SECTION 903. Fig. 404.2.3 ! 903.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE TURNING SPACE ; r - - - - _ g 1 12" 1 COMPLYING WITH SECTION 305, POSITIONED FOR PARALLEL Ref. Section 304 - - - - < 22" ( r - - - - - , I I I n MIN. APPROACH TO THE BENCH SEAT, SHALL BE PROVIDED. - - = MIN. 1 I ( x _ z I z z I ( (A) 903.3 SIZE. BENCHES SHALL HAVE SEATS 42 INCHES (1065 22" & L1 24" I I 24^ I z MM) MINIMUM IN LENGTH, AND 20 INCHES (510 MM) MINIMUM Nµ ( MIN. I MIN. (� MIN. I �a AND 24 INCHES (610 MM) MAXIMUM IN DEPTH. �. l� 903.4 BACK SUPPORT THE BENCH SHALL PROVIDE FOR - 48+� BACK SUPPORT OR SHALL BE AFFIXED TO A WALL. BACK I -�� SUPPORT SHALL BE 42 INCHES (1065 MM MINIMUM IN 1 �ti�1 POCKET OR HINGE APPROACH HINGE APPROACH, PUSH SIDE; LATCH APPROACH, PULL SIDE LATCH APPROACH, PULL SIDE; PUSH SIDE; LENGTH AND SHALL EXTEND FROM A POINT 2 INCHES (51 0 1 - LjI I (� �I o ( i - - - DOOR w/ BOTH CLOSER & LATCH DOOR w/ CLOSER DOOR w/ BOTH CLOSER & LATCH ' MM) MAXIMUM ABOVE THE SEAT SURFACE TO A POINT 18 JI Lf �J 1_»I �� INCHES (455 MM) MINIMUM ABOVE THE SEAT SURFACE. 30" 48" (- - - - - - -1 - - _ _ _ _ _ MANUAL SWINGING A) BACK SUPPORT SHALL BE 21/2 INCHES (64 MM) MAXIMUM FROM THE REAR EDGE OF THE SEAT MEASURED Z I I o Z I I z I I DOORS & GATES RECESSED DOORS & GATES Fig. 303.3 HORIZONTALLY. I 24" a I 1 it 0 Fig. 404.2.4.1 Fig. 404.2.3 BEVELED CHANGES IN LEVEL MIN. g 24" �a 1 24" I �a CLEAR FLOOR SPACE FORWARD APPROACH PARALLEL APPROACH I I I MIN. < ( MIN. 1 < NOTE: 903.5 HEIGHT. THE TOP OF THE BENCH SEAT SHALL BE 17 Fig. 305.3 Fig. 305.5 (a) Fig. 305.5 (b) ( ( CHANGES IN LEVEL GREATER THAN 1/2" MAXIMUINCHESMABOVE30 THE MINIFLOOR,MUM NMEASURED TO D 19 INCHES (THE 485 MOP OF MANEUVERING CLEARANCE NOTES: SHALL BE RAMPED, AND SHALL COMPLY THE SEAT, (d.) 1. DOORS, DOORWAYS AND GATES PROVIDING USER PASSAGE SHALL w/ SECTIONS 405 OR 406. (303.4} STOP OR LATCH APPROACH COMPLY (206.5) EXCEPTION: BENCHES PRIMARILY FOR CHILDREN'S USE MINIMUM CLEAR FLOOR SPACE 2. ADJUST DOOR CLOSERS SO THAT THE DOOR TAKES AT LEAST 5 SHALL BE PERMITTED TO BE 11 INCHES (280 MM) MINIMUM Ref, Sections 304 & 305 DOORWAYS w/a DOORS. SLIDING 0.) (k) SECONDS TO MOVE FROM 90 DEGREE OPEN POSITION TO 12 DEGREES FLOOR & GROUND SURFACES AND 17 INCHES (430 MM) MAXIMUM ABOVE THE DOORS GATES & FOLDING DOORS LATCH APPROACH, PUSH SIDE LATCH APPROACH, PULL SIDE; FROM LATCH (404.2.8) Ref. Sections 302 & 303 FLOOR, MEASURED TO THE TOP OF THE SEAT. Fig. 404.2.4.2 DOOR w/ CLOSER 3. FIRE DOORS SHALL HAVE MINIMUM OPENING FORCE ALLOWABLE BY 903.E STRUCTURAL STRENGTH. ALLOWABLE STRESSES SHALL THE BUILDING AND FORE CODES. OTHER INTERIOR DOORS, 5 POUNDS MAXIMUM. (404.2.9) NOT 4. MANEUVERING CLEARANCES ARE REQUIRED AT AUTOMATIC DOORS BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR MANEUVERING CLEARANCES UNLESS DOOR OPERATION HAS STANDBY POWER (404.3.2) HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED Ref. Section 4042.3 AT ANY POINT ON THE SEAT, FASTENER MOUNTING DEVICE, OR SUPPORTING STRUCTURE, M: ANY OPERABif PART OF ANY ONCE 8" SHALL INSTALLED WrHN WItf9N THE REACHES SNOXN MIN. 20" >20"-25" 10" loll +10"-24" MAX. MAX. r - z r (I O I I t it \�� t -i MA 11" 25" ( m a li 1 �i 1 X. MIN.. i7" 25 MAX. (°) (b) (°) (b) f ELEVA1ION PLAN ELEVATION PLAN Fig. 308.2.1 Fig, 308.2.2 Fig. 308.3.1 Fig. 308.3.2 Fig. 306.2 Fig. 306.3 UNOBSTRUCTED OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH TOE CLEARANCES KNEE CLEARANCES FORWARD REACH REACH RANGES KNEE & TOE CLEARANCES Ref. Section 308 Ref. Section 306 NOTES: I 4" MAX. 32 ALTERNATE DOOR 6" MIN. TOILET ROOM NOTES: 1. PROTRUDING OBJECTS SHALL NOT REDUCE THE I MIN LOCATION 1. A TURNING SPACE PER SECTION THIS DRAWING IS A REPRESENTATIVE REQUIRED WIDTH OF AN ACCESSIBLE ROUTE , \, I - - - - - - 304 IS REQUIRED WITHIN A SUMMARY OF THE REQUIREMENTS OF (307.5) "'" ( TOILET ROOM (603.2.1} AT I THE 2010 ADA STANDARDS THAT 1�- PARTITION z ;, I 2. ONLY THE FOLLOWING OBJECTS MAY BE APPLICABLE TO THE 2. PROTRUDING OBJECTS ON A CIRCULATION PATHSHAtt COMPLY w/ z I _ M D P WHERE SPECIFIC INFORMATION AND ARE PER ITTE TO OVERLA I THE REQUIRED CLEARANCE: 71 ' z "^ GRAB BARS, DISPENSERS, CLEARANCES ARE NOT NOTED ON n I I '� 1 THE DRAWINGS, CONSTRUCT TO THE rn M SANITARY NAPKIN DISPOSAL CLEARANCES AND TOLERANCES PROTECT SHADED AREA FROM (CLEAR - 4" L - - - - I I n _- -_ ^ SHELVES (604.3 2) UNIT, COAT HOOKS AND SHOWN ON THIS SHEET. WHERE CROSS -TRAFFIC 1 WIDTH MAX. �/ 3. FLUSH CONTROLS SHALL BE 60" MIN. fill DRAWINGS SPECIFICALLY INDICATE F APPROACH %, MpX. I APPROACH DIFFERENT OR CONFLICTING z 1 LOCATED ON THE OPEN SIDE 42" MIN. 56" MIN. w WALL MID. W.C. (°) (c} I 42" MIN. 60" MiN. OF THE WATER CLOSET (604.6) INFORMATION TO THE STANDARDS z Fig. 604.3.1 ELEVATION PLAN DEPICTED ON THIS SHEET, 4. URINALS SHALL HAVE A CLEAR CLEARANCE AT WATER CLOSETS I 59" MIN. w/ FLR. MID. W.C. I FLOOR SPACE COMPLYING WITH CONSTRUCT USING THE MORE 305 POSITIONED FOR FORWARD STRINGENT REQUIREMENT OR WHEELCHAIR ACCESSIBLE TOILET LAPPROACH AND CENTERED ON CONTACT THE ARCHITECT FOR II� WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT COMPARTMENT TOE CLEARANCE AMBULATORY ACCESSIBLE TOILET COMPARTMENT RESOLUTION UNIT (605.3) CANE DETECTION AREA Ref. Section 604 Fig. 604.8.2 Fig. 604.8.2 5. LAVATORIES SHALL HAVE A CLEAI FLOOR SPACE C MPL NG WITH 305 Fig. 307.5 Fig. 307.2 I- 39'41" POSITIONED FOR FORWARD VERTICAL CLEARANCES LIMITS OF PROTRUDING OBJECTS z W MIR L. APPROACH AND CENTERED ON g fi 36" MIN. I UNIT (606.2) r 12" MAX, 4YAN 1 1 4"-2" !a-1 2" f 12" MIN. r MIRROR 6. KNEE & TOE CLEARANCE it 24 lIN i' COMPLYING WITH 306 SHALL BE CIRCULAR _I f �l f PROVIDED (602.2) - T/ GRAB_ BAR_ _ ! 7. EXPOSED WATER SUPPLY AND in 12" % l' f _ c- FLUSH CONTROL j X DRAIN PIPES SHALL BE j f M 9 (OPEN SIDE) f. X w INSULATED. THERE SHALL BE o MAX, v z (' r: i. o n o NO SHARP OR ABRASIVE X > 12 < " r SURFACES UNDER LAVATORIES REV w {606.5) ff./'f;ff: i .: if/.',' �i..:,!/. ri i'f i9y ,,, ff<.�4 i;5:" , f., f f B. INSTALL GRAB BARS TO CODE 42" 9AX o i6"-18' ' i5" WITHSTAND NOT LESS THAN A ACCESSIBLE Al Fig. 307.3 (o) Fig. 307.3 (b) PROJECTING OBJECTS RECESSED OBJECTS ^ Ref. so+.z I I MIN. 250 POUND FORCE APPLIED AT ANY POINT ON THE BAR POST -MOUNTED PROTRUDING OBJECTS SPACING OF GRAB BARS TOILET URINAL LAVATORY (609.8) GUIDELINES- Fig. 609.3 Ref. Section 605 Ref. Sections 606 & 603.3 PROTRUDING OBJECTS TOILET ROOM CLEARANCES & MOUNTING HEIGHTS BU City ILD Ref. Section 307 Ref. Chapter 6 s2o7 REGISTERED ARCHITECT ERIC E. KOCH STATE OF WASHINGTON V A o tvo� N O � C7 q 0 Of 4 W C N � R w ,�% 3 c Ix i Q H N +m. H 2 a VIP d Z O d O w m < o � m AWN: rC E1={C ECK: �� I JOB NO: 19-023 ff Z -1 z mm W (� IEWED FOR - ym COMPLIANCE a )PROVED ''nn CT 31 2019 of Tukwila ING DIVISION RECEIVED CITY OF TUKWILA SEP 2 5 2019 PERMIT CENTER SHEET: OF: - SHEETS i 8 7 5i8• 3'-0' EXISTING CHASE WALL TO REMAIN REMOVE EXISTING DOOR AND FRAME EXISTING MECHANICAL CHASE TO REMAIN EXISTING EXPOSED CONCRETE BASEMENT WALL n C)E f0 PLAN NEW INTIMATE APPAREL FITTING RM. SCALE: 1/4'=1'-0' DEMO PLAN CH I LDPEN& FITTING RM. SCALE: 1/4'=1'-0' '� ENL IRGED FLOOR PLAN 5A6E1" LENT FITTING RM, SCALE: 1/4' =1'-0' FLOOR PLAN CH I LDRENS FITTING RM. SCALE: 1/4'=1'-0' ri'PES SCALE: EXISTING 3-5/8' METAL STUD WALL SYSTEM WITH 5/8' TYPE 'X' GWB - NEW 1/2' HAT CHANNELS OVER EXIST. STUDS NEW 5/6' TYPE 'X' G.W.B. NEW 3625125-30 METAL STUDS 9 24' O.G. SLIP TRACK AT TOP OF WALL. ATTACH TOP W/ POWDER ACTIVATED FASTENERS (2) PER CONC, JOIST ABV. SEE DET. 4/A2.2 NEW 5/6' TYPE 'X' G.W.B. CONTINUOUS BOTTOM TRACK SECURED TO SLAB W/ J45 X 1/2' POWDER ACTIVATED FASTENERS a 16' O.C. EXISTING BASEMENT CONCRETE WALL NEW 3626I25-30 METAL STUDS 0 IV O.C. EXTEND WALL TO UNDERSIDE OF CEILING NEW 5/6' TYPE 'X' G.W.B. R-fo RIGID INSULATION AT BELOW GRADE WALL R-13 BATT INSULATION BETWEEN STUDS 6 MILL VISOUEEN VAPOR BARRIER UNDER DRYWALL ON WARM SIDE OF WALL CONTINUOUS BOTTOM TRACK SECURED TO SLAB W/ .145 X 1/2' POWDER ACTIVATED FASTENERS 9 IV O.G. READY ro xva Es ES _ IENR(FA�'IEAs aP SPIXt1sWEAR R REAov ro WEAR w o 0 0 G G O O G o O SPgiSW o �o DRESSES C4 CX-M'S 9 m SPgtRWGA ACDK FS m wcc 0 0 0 O fiMS K p p p FS �A-T' YWR ,�wS FR RFAOY TD MEAR f REAnr ro W&w f8 s FlNISiiI1NE DP HANDDA45 SNCZS CHItDRENR 0 0 0 o VS o o 0 Fp o oP NM'S SNDES FlNI9NNE � W DRESS ACCESS OP WNE tME � MENS FS W .£WCL4Y(WAiCNES E5 DP SPPRISWFPR LP mWs S m mExD D uv G G ti a ® o R�EADr TD WEAR WS / MNC MS I W .ENS O G 0 G o um rs s READY ro WEAR MDw ( YgMC MEN M' T. rs READY ro WEAR W 1E%iIlES DAP HCUSlWARES 0 0 auNS/ uxcMw05 o c 0 0 0 o a o 0 0 rs rs 1� C MAFNS CHIIA9EN'R W WRFN'R --�—y � uw5 ! YUA+c MEa'S A-2.1 O— o O O G G C O 1 I MArzm+ltt rs o altDr:txS I o 0 0 0 ( I auu�REM•s I •� `I]r • I City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 5 2019 PERMIT CENTER ci g C) a a ci O N m 3 d c Q A "Il N ® i RZ Q z O F- d � O w o w W m Iw— Q Q � o � m w DRAWN: 1"m CHECK: EE1G JOB NO: 19-023 441 LLI U •` U z to (�['\ 0 Di OL � \Jj 0IL �m J l G SHEET: ® .1 <EY PLAN - 5A5EMENT N.T.S. 1 OF: — SHEETS DEMOLITION GENERAL NOTES CONTRACTOR SHALL VISIT THE JOBSITE AND CAREFULLY EXAMINE WORK TO BE DEMOLISHED 50 AS TO BECOME COMPLETELY FAMILIAR WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO NATURE AND SCOPE OF WORK ANY DISCREPANCIES FOUND BETWEEN THE ACTUAL FIELD CONDITIONS AND THE WORK INDICATED ON THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. THE WORK INDICATED FOR THE PROJECT 15 TO BE PERFORMED IN AN EXISTING RETAIL FACILITY THAT SHALL REMAIN IN CONTINUOUS OPERATION THROUGHOUT THE ENTIRE COURSE OF CONSTRUCTION. THE CONTRACTOR SHALL CONDUCT ALL DEMOLITION WORK IN A MANNER THAT WILL MINIMIZE THE DISRUPTION OF OWNERS NORMAL BUSINESS OPERATIONS. PRIOR TO COMMENCEMENT OF DEMOLITION PROCEDURES, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONSTRUCTION DOCUMENTS SO AS TO PROPERLY COORDINATE DEMOLITION WITH THE REQUIREMENTS OF THE NEW CONSTRUCTION INDICATED. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER ITEMS THAT ARE TO BE RETAINED AND REUSED. ITEMS REUSED ARE TO BE STORED ON SITE FOR SUBSEQUENT REMOVAL BY OWNER ALL OTHER ITEMS SCHEDULED FOR DEMOLITION SHALL BECOME PROPERTY OF THE CONTRACTOR AND REMOVED FROM THE SITE. CONTRACTOR SHALL MAINTAIN WORK AREA IN A CLEAN AND ORDERLY MANNER THE PREMISES SHALL BE KEPT BROOM CLEAN AND FREE FROM THE ACCUMULATION OF WASTE MATERIALS AT ALL TIMES. ALL DEMOLITION DEBRIS SHALL BE CONTAINED WITHIN THE WOW AREA AND REMOVED ON A REGULAR BASIS. PROVIDE NECESSARY BARRICADES AND SHIELDS AS REQUIRED FOR THE PROTECTION OF OWNERS PERSONNEL AND THE GENERAL PUBLIC AROUND WORK AREAS AND TO AND FROM OCCUPIED PORTIONS OF THE BUILDING. REFER TO NEW FLOOR PLAN FOR RELATED DIMENSIONS TO ASSIST IN DETERMINING THE SCOPE OF THE DEMOLITION OF PARTITION ELEMENTS. COORDINATE EXISTING CONDITIONS TO BE PARTIALLY DEMOLISHED WITH NEW WALL, DECOR, CEILING AND FLOORING CONDITIONS SO THAT DEMOLISHED AREAS ARE PREPARED TO PROPERLY ACCOMMODATE THE NEW WORK INDICATED. PROTECT ADJACENT EXISTING SURFACES OF CONSTRUCTION AND FIXTURING SCHEDULED TO REMAIN. AS DEMOLITION OPERATIONS PROCEED, THE CONTRACTOR SHALL SHORE OR BRACE EXISTING WORK TO REMAIN 50 AS TO STABILIZE ALL CONDITIONS AND LEAVING EXISTING WORK IN STRUCTURALLY SOUND CONDITION. EXISTING SURFACES DAMASED OR DISTURBED DUE TO DEMOLITION OPERATIONS SHALL BE PATCHED OR REPLACED AS REQUIRED TO MATCH AND ALIGN WITH ORIGINAL CONDITIONS. COORDINATE RELOCATION OF EXISTING CASH WRAPS AND POS REGISTERS WITH OWNERS PROJECT MANAGER AND STORE MANAGER DEMOLITION CONTRACTOR TO COORDINATE WITH MECHANICAL CONTRACTOR FOR ANY THERMOSTAT RELOCATION. CONTRACTOR TO STUDY NEW PLANS AND NEW RCP PLANS FOR NEW CEILING LIGHTING. REPORT ANY CONFLICTS WITH EXISTING HVAC EQUIPMENT, DUCTWORK, PLUMBINS, ELECTRICAL OR MECHANICAL TO REMAIN TO THE ARCHITECT. REFER TO WRITTEN SPECIFICATIONS AND RESPONSIBILITY SCHEDULE FROM OWNERS REPRESENTATIVE. � S o N 0 t C tff O 4 d O N 3 CL.0 E Q N m 0 H Q 0 N M "ad 1� 1t.! w I— A � wI O � UJ a� a �wm m �'Onn O o q Q� u CONTRACTOR TO MAINTAIN CONSTANT DUST CONTROL DURING ALL OPERATIONS. PROVIDE DUST SCREENS AS MAY BE REQUIRED FOR THE PROTECTION OF SALES AREAS FROM DUST AND DEMOLITION OPERATIONS. COORDINATE LOCATION OF DUST SCREENS WITH THE OWNER CONTRACTOR IS TO SAVE AND STORE AS MANY EXISTING CEILING TILES AS POSSIBLE FROM BACK AREAS TO BE RE -USED ON THE SALES FLOOR AREA. STOCK SHELVING CONTRACTOR TO SALVAGE ALL EXISTING STOCK SHELVING AND PARTS FOR RE -USE. RECEIVED CITY OF TUKWILA KEY FLAN FLOOR SEP 25 2019 N.T.S. MtT CENTER OF: - SHEETS 15. 3 FAIR BUTT HINGE, LEVER HANDLE, I-A55AGF= 5F=T ts c: O C L 0 t z 0 F— LL x fl) U) LLJ lai < Tl- TU tr DRAWN: mm CHECK: r=r=i< JOB NO: ca ff w f-- Z w u- z c() 2 � 0 I pQ LL E u- SHEET: FAA RECEIVED CITY OF TUKWILA KEY FLAN 3RD FLOOR SEP 25 2019 PERMIT CENTER N.T.S. IOF: — SHEETS 7 EGISTE E � ARCHITECT tN-20 ETC KOCH IT I IF IAS[i]"TN A �E ? t: ccls, 246mm C181 ni ff O UJ ui 01 SHEET: 74-2.4 -Z f.-I O F-I PENDENT FIXTURE - LED BULB 32 WATT CITY OF TUKWILA SEP 2 5 2019 KE'r PLAN 3RD FLOOR PERMIT CENTER N.T.S. OF* IHEETS