Loading...
HomeMy WebLinkAboutPermit D19-0379 - SUMI KOREAN GRILL - INTERIOR IMPROVEMENTSUMI KOREAN GRILL 17250 SOUTHCENTER PKWY 148 FINALED 11/20/2020 D19-0379 Parcel No: Address: City °~fTukwila Department mfCommunity 63OO5outhcenterBoulevard, Suite #1OO Tukwila, Washington 981O8 Phone:2O6'431']670 Inspection Request Line: 205'438'9350 Web site: http://www.Tukwila'WA.Rov DEVELOPMENT PERMIT 7888920020 Permit Number: D19-0379 17250SOUTH[ENTERPKVVYI48 Issue Date: 2/27/2020 Permit Expires On: 8/25/2020 Project Name: SUMI KOREAN GRILL Owner: Name: Address: Contact Person: Name; Contractor: Name: WIG PROPERTIES LLC-SS 4811134THPLSE,BELLEVUE,VVA, 98006 N[8NAR|N l4OS8OYL5TONAVE, 3EATTLE VVA' 98122 Address: 14150 125TH AVE NE, KIRKLAND, WA, 98034 License No: CDCONDC8231\18 Lunde,: Name: STARDUST HOSPITALITY LLC Address: 4006S212TH[T#D'SEATA[ WA, 98198 Phone: (206)466-9753 Expiration Date: DESCRIPTION OFWORK: INTERIOR ALTERATIONS FROM EXISTING PIZZA RESTAURANT INTO NEW KOREAN GRILL. INSTALLING NEW COMMERCIAL KITCHEN EQUIPMENT, INTERIOR FINISHES &FURNITURE. Project Valuation: $150,000.00 Type nfFire Protection: Sprinklers: YES Fire Alarm: NO Type ofConstruction: 118 Electrical Service Provided by: TUKWILA Fees Collected: $3,421.58 Occupancy per IBC: B Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 015 ZUB 20,15 2015 National Electrical Code: WA Cities Electrical Code: VVA[296-468: Code: Public Works Activities: [hanne|ization/Striping: CurbCut/\ccess/Sidewa|kc Fire Loop Hydrant: Flood Control Zone: Hau|in8/Ovem|zeLoad: Land Altering: Landscape Irrigation: Sanitary Side Sewer; Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: O Fill: O Number: O No Permit Center Authorized Signature: ,�� `~�-- 7 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions nflaw and ooGnances governing this work will becomplied with, whether specified herein nrnot. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state nrlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and! agree tnthe conditions attached tothis permit. Signature: Print Name: �- J'3�/(; HbD Wh o2l 27/ 20J^, This permit shall become null and void if the work is not commenced within 180 days for th,e date of issuance, or if the work is suspended orabandoned for aperiod of18Odays from the last inspection, PERMIT CONDITIONS: 27: The BBQ Grills and associated ductwork/equipment shall require a separate mechanical permit. 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,S0Osq. ft. of area. The extinguisher(s) should be of the ''AU Purpose" (3A,4OB:[)dry chemical type. Travel distance toany fire extinguisher must be7S'orless. (|FC 906.3)(NFPA10'5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers orbrackets shall besecurely anchored tothe mounting surface inaccordance with the manufacturer's installation instructions. Portable fire extinguishers having agross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top isnot more than 3.Sfeet (1U67mm)above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (|FC9O6.7and |FC 906.9) Z: Extinguishers shadl be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall bealong normal paths oftravel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of 19: A�realarm qotemisequ�edfor this project. The fire alarm system shall meet the requirements of N.F.P.A.7Zand City ordinance #2437. ZO: All new fire alarm systems ormodifications toexisting systems shall have the written approval ofThe Tukwila Fire Prevention Bureau. Nowork shall commence until afire department permit has been obtained. (City Ordinance #2437)(|F[9O1J) 21: Maintain fire alarm system audible/visual notification. Addition/relocation ufwalls orpartitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #Z437) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA7U) 24: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth inTable No. Q03.I1of the International Building Code. 28: In other than Group 1-3, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.4 and shalknot exceed 10 percent ofthe specific wall nrceiling area towhich they are attached. (|FC887.1) Where required toexhibit improved fire performance, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls urceilings shall betested byanapproved agency and meet the flame propagation performance criteria of Test Method 1 or Test Method 2, as appropriate, of NFPA 701 or exhibit a maximum rate of heat release of100 kVVwhen tested in accordance with NFPA289, using the ZO kVVignition source. Reports of test results shall be prepared in accordance with the test method used and furnished tothe fire code official upon request. (|F[807.4) 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) ZS: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ofsuch condition orviolation. 26: These plans were reviewed byInspector 511. |fyou have any questions, please call lukwUnFire Prevention Bureau at(ZO6)S75-4407. Zg: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. ]O: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 31: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. AS[E7,Chapter l3. 32: Partition walls shall not betied toasuspended ceiling grid. All partitions greater than 6feet )nheight shall be laterally braced tothe building structure. Such bracing shall be independent ofany ceiling splay bracing, 33: Readily accessible access to roof mounted equipment is required. 34: All construction shall be done in conformance with the Washington State Building Co -de and the Washington State Energy Code. 35: Structural Observations inaccordance with |.BI. Section I709isrequired. Atthe conclusion ofthe work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, tothe best ofthe structural observer's knowledge, have not been resolved. 36: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior toopening ordoing any food processing. Arrangements for final Health Department inspection shall bemade bycalling Seattle/King County Department nfPublic Health, (1'8OO'J2S'6165ext9'S66),atleast three working days prior todesired inspection date. Onwork requiring Health Department approval, itis the contractor's responsibility to have a set of plans approved by the agency on the job site. 37: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 3: Fire extinguishers require monthly and yearly inspections. They must have atag orlabel securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall beemptied and subjected tuthe applicable recharge procedures, |fthe required monthly and yearly inspections cfthe fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable oranimal oils and fats shall beprotected bya Class K rated portable extinguisher. (|F[9O4.lI.S) 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (|FC10101g) 7: Exit hardware and marking shall meet the requirements ofthe International Fire Code. (|F[Chapter 1O) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist tooperate. (|F[l0l0l9l) 9: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access toexits shall bemarked byreadily visible exit signs )ncases where the exit orthe path ofegress travel isnot immediately visible tothe occupants. Exit sign placement shall besuch that nopoint in an exit access corridor is more than lOOfeet (3O,480 mm) or the listed viewing distance for the sign, whichever isless, from the nearest visible exit sign. (|F[lU131) 10: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes ofthe letters not less thanOJS inch (l9.1mm) wide. The word "[X|T'shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not beless than O.375inch (9.Smm). Signs larger than the minimum established in the international Fire Code shall have letter widths, strokes and spacing inproportion totheir height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. if an arrow is provided as part of the exit sign, the construction shall hesuch that the arrow direction cannot bereadily changed. (|F[lOI3.6.l) ll: Each door inameans o(egress from anoccupancy ofGroup AorEhaving anoccupant load of50urmore and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit hardware, (|F[101OIlO) 12: Exit signs shall beilluminated atall times, Toensure continued illumination for aduration ofnot less than 9Ominutes incase ufprimary power loss, the sign illumination means shall beconnected toanemergency power system provided from storage batteries, unit equipment or on -site generator. (|F[lUI3.63) 13: Every room or space that is an assembly occupancy shall have the occupancy load of the room orspace posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (|F[lO04.3) 14: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot'canme(I1 lux) and minimum atany point of0.1foot-candle (1 lux) measured along the path of egress atfloor level. Illumination levels shall hepermitted todecline tnU.6foot-candle (6lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration, A maxim um-to'mirimu,nillumination uniformity ratio of40 tolshall not beexceeded. (|F[ID0D3.5) 18: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations tofire protection systems shall bedone inaccordance with applicable standards. (|F[9Ol.4) 16: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPAl3-86.5.3.3) 15: All new sprinkler systems and all modifications toexisting sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior tosubmittal tothe Tukwila Fire Prevention Bureau. Nosprinkler work shall commence without approved drawings. (City Ordinance No. Z430). 38: All rack storage requires aseparate permit issued through the City ofTukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed inthe State ofWashington. Periodic special inspection isrequired during anchorage ufstorage racks 8feet orgreater inheight. 39: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 40: Remove all demolition rubble and loose miscellaneous material from lot or parcel of'ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements., cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion ofthis requirement. 41: ACertificate ofOccupancy shall beissued for this building upon final inspection approval byTukwila building inspector. 42: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4-inches shall be maintained above the controls with the stra pping. 43: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City nyTukwila Building Department (285-431']O70). 44: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 45: VALIDITY OFPERMIT: The issuance orgranting ofapermit shall not beconstrued to. beapermit for, oran approval of, any violation ofany ofthe provisions of the building code urofany other ordinances cf the City of Tukwila. Permits presuming togive authority toviolate o,cancel the provisions cfthe code orother ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based nnconstruction documents and other data shall not prevent the Building Official from requiring the correction u/errors in the construction documents and other data. 46: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (2U6/43l'307O). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2V6)438'g35V 1700 8U|LD|NGF|NAL** I400 FIRE FINAL 0409 FRAMING 0502 L4TM/GYPSVMBOARD 1800 MECHANICAL FINAL 1900 PLUMBING FINAL CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 1) /' -q Project No. Date Application Accepted: Date Application Expires: /2 - Co -3 —2-0 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail. **Please Print** SITE INFORMATION Site Address: 1 72 50 5014-4-1 Cen1T& Tenant Name: (SO rill k0 Q.(-i (4- R. t j.,. (,, PROPERTY OWNER Name: I vl c l'~(,) Address: L{ Cb I l 14 e L S City: n �tt/t t,,1li 6 State: 1 AJ A Zip: q boo (0 CONTACT PERSON — person receiving all project communication Name: Nab Ni-fit Address: 14 o5 60 lk,, 5.17J‘j ft V €' City: She State: WI Zip: 19 t2l t Phone: Zn (o . 3 2 Z. Li32 3 Email: N0SP, CATCNs-Walo • CoT-,1 CHARGE DESIGN PROFESSIONALIIINJe JRESPONSIBLE Name: Rd of w .�V k Address: Ho S 8o`(cs tav fty� ''11r City: S Ti A t 7 liC✓ 1/ " G State: ' ^I Zip: �.lJ Q1 12 Phone: w 6 , 37 .� ? 2u 3-r /4 /�2 p f,, �► Email:pz, Gk k. l`_'/ CTt tc,t1 .51 410 - l L_ GENERAL CONTRACTOR INFORMATION Company Name: OA_Q e Wttpsk Q �r�Srt��cct - Address: 1 L 2. 113 R 2 sr. 5 ` City: L`i 1`rnIlIV 00D State: vi A Zip: Phone: 3(,0,eig0'e8;(0 St Contr Reg No.: 10 0 q 3 / O 61 0. b V Exp Date: ID /31 £ f% Tukwila Business License No.: King Co Assessor's Tax No,: 7 Q)Q)S '(Z o O Z 0 Suite Number: 1 '(t Floor: 1 New Tenant: kYes ..No ARCHITECT OF RECORD Company Name: C>"Ctak DeL516.1r,s ITOtO Address: t (-40 . AST N AVE City: State: t,L)P\ Zip: q'81•L2 S6.7.0....rL6 Phone: Q,,�,2i , tl3Z3 7e Email: --Fvfi +r „A`.1y"i{ ,S-rv)p10 . cor-'1 ENGINEER OF RECORD Company Name: Address: City: State: Zip: Phone: Email: LENDER — WHO IS FUNDING THE PROJECT (required for projects $5,000 or greater per RCW 19.27.095) Name: 5V ITmI-r i G1,C Address: +-I 00 (o S S. 212i N GT A D City: 5 c, State: 1/j A. Zip: GI B lib MONTHLY SERVICE BILLING -or- WATER METER REFUND/BILLING Name: Address: City: State: Zip: Phone: W:\Permit Center (Rachelle)\Applications\Word\Construction Permit Application Revised 6-2019.docx Revised: June 2019 Page 1 of 3 BUILDING DIVISION INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 101°00 Existing Building Valuation: $ q (705, 1400. cr2 Describe the scope of work (please provide detailed information): I n)-f-r-aLog '45 r-12.01-.1 &flPJ(1 p r le-Est-Prova-AriT N.)-rr2 NE-1"J lezet-gtr.l &IRA IA, • INS -PA -WA frt e•i/ Will there be new rack storage? O.. Yes .No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC ls' Floor 5O .f 2) 0 a Nfrt r-J/A 1 1 - g 2'd Floor 3'd Floor ----- Floors thru -- Basement ------- Accessory Structure* .----. Garage 0 Attached 0 Detached ---. Carport E3 Attached 0 Detached Covered Deck Uncovered Deck PLANNING DIVISION INFORMATION — 206-431-3670 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? D.. ..... Yes Compact: Handicap: No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS — 206-575-4407 34. Sprinklers O., ..... Automatic Fire Al ann E3 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x I I" paper including quantities and Material Safely Data Sheets. PUBLIC WORKS INFORMATION — 206-433-0179 r] ...Permanent Water Meter Size (1). O ...Temporary Water Meter Size (1). ED -.Water Only Meter Size 0 ,..Sewer Main Extension Public WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # 0 ......,.Deduct Water Meter Size ,. Private 0 O.-Water Main Extension Public 0 Private 0 WAPermit Center (Rachelle)'Applications \ Word \Construction Permit Application Revised 6-2019.docx PrviricaA, 1,,,, lO 13,110,P 1 1 0 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAM1Is4ED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU 0 • ZED AGENT: Signature: Date: Print Name: 0\---Jelir/P1 Day Telephone: .2.0 - - 3 Mailing Address: / Lios ec)-{c.sf..1 'VP S611111,& JAJ Pc. 1'6N 72 City State Zip W:\Permil Center (Rochelle) \Applications\ Word \Construc-tion Permit Application Revised 6-2019.docx Revised: June 2019 Page 3 of 3 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID D19-0379 Address: 17250 SOUTHCENTER PKWY 148 Aprl: 7888920020 $2,099.10 DEVELOPMENT $2,000.33 PERMIT FEE WASHINGTON STATE SURCHARGE TECHNOLOGY FEE TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R20280 R000.322.100.00.00 B640.237.114 R000.322.900.04.00 0.00 0.00 0.00 $1,975.33 $25.00 $98.77 $98.77 $2,099.10 Date Paid: Thursday, February 27, 2020 Paid By: STARDUST HOSPITALITY LLC Pay Method: CHECK 1036 Printed: Thursday, February 27, 2020 3:02 PM 1 of 1 SYSTEMS Receipt Number DESCRIPTIONS i ACCOUNT QUANTITY PAID PermitTRAK $1, 406.94 D19-0379 Address: 17250 SOUTHCENTER PKWY 148 Apn: 7888920020 $1,322.48 Credit Card Fee $38.52 Credit Card Fee R000.369.908.00.00 0.00 $38.52 DEVELOPMENT $1,283.96 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,28396 PG19-0185 Address: 17250 SOUTHCENTER PKWY 148 Apn: 7888920020 $84.46 Credit Card Fee $2.46 Credit Card Fee R000.369.908.00.00 0.00 $2,46 PLUMBING $82.00 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R19199 0.00 $82.00 $1,406.94 Date Paid: Tuesday, December 03, 2019 Paid By: YINGHUI HU Pay Method: CREDIT CARD 645101 Printed: Tuesday, December 03, 2019 1:04 PM 1 of 1 I? SYSTEMS CITY OF TUKWILA 0017340000802374464500 ,Date: 12/03/2019 01:04:13 PM CREDIT CARD SALE MASTERCARD X {CARDHOLDER'S SIGNATUREJ I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Catch Design Studio 1405 Boylston Ave Seattle, WA 98122 P# 206-322-4323 SUMI KOREAN GRILL D19-0379 December 27th 2019 December 27, 2019 NOS NARIN 1405 BOYLSTON AVE SEATTLE, WA 98122 BUILDING Correction Letter # 1 DEVELOPMENT Permit Application Number D19-0379 SUMI KOREAN GRILL - 17250 SOUTHCENTER PARKWAY 148 Dear NOS NARIN, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: LEE SIPE at (206)-431-3656 if you have questions regarding these comments. (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC196-23-010 try RECEIVED 196-23-020). Architects: "date" only not required (WAC 308-12-081). OF TUKWILA CORRECTION JAN 0 8 2020 LTR# o37/ PERMIT CENTER (BUILDING REVIEW NOTES) Corrections Required: 1. Common path of egress travel distance is greater than 75' for a single exit. how will this be addressed? Table 1006.2.1, Table 1006.3.2(2). o Added table 1006.2.1 "Spaces with one exit or exit access doorway". Provided the occupancy group B with sprinkler system could has the maximum common path of egress travel =100 feet. Maximum egress distance from dining area = 98 feet and maximum egress distance from the kitchen = 68 feet. See page A2. 2. 1 HR. fire rated corridor walls per Table 1020.1 o Added table 1020.1 "Corridor fire resistance rating" The space is a B occupancy with a sprinkler system, therefore according to Table 1020.1 the fire resistance rating required is O. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. D19-0379 - 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 - city of Tukwila Department of Community Development December 27, 20I9 NOS NARIN 1405 BOYLSTON AVE SEATTLE, WA 98122 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D19-0379 SUMI KOREAN GRILL - 17250 SOUTHCENTER PARKWAY 148 Dear NOS NARIN, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: LEE SIPE at (206)-431-3656 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x 17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) Corrections Required: 1. Common path of egress travel distance is greater than 75' for a single exit. how will this be addressed? Table 1006.2.1, Table 1006.3.2(2). 2. 1 HR. fire rated corridor walls per Table 1020.1 Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. D19-0379 Vro/eflinnrons• P.n•der,,ermei C11,it..1 //In To.1"..11e. n 4? / t")DL..1I1.4 42 / 47/1 V.... /IX 421 2.CZ-G PERMIT WORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0379 DATE: 01/08/2020 PROJECT NAME: SUMI KOREAN GRILL SITE ADDRESS: 17250 SOUTHCENTER PKWY - SUITE 148 Original Plan Submittal X Response to Correction Letter # DEPARTMENTS: 010 ir Aiilding Division Public Works ri Fire Prevention Structural Revision # before Permit issued Revision # after Permit issued r Lil Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/09/2020 Structural Review Required REVIEWER'S INITIALS: DATE: 1-1 APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DA IL: 02/20/2020 Approved with Conditions El Denied (ie: Zoning Issues) Notation: REVIEWERS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire D Ping PW Staff Initials: 12/18/2013 CENT MORD COPY ° PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0379 DATE: 12/4/2019 PROJECT NAME: SUMI KOREAN GRILL SITE ADDRESS: 17250 SOUTHCENTER PARKWAY STE 148 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS; CO tiR, Atit C t14,y13 Al° P--1 Building Division Fire Prevention II Planning Division 44 tik 11,111 Public Works Structural n Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/5/19 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews LI Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 1nn020 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued issued corrections: Bldg Fire El Ping D PWD Staff Initials: IZ/18/2013 Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Ch_ REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. 01 /0 3 11,0 2-0 Plan Check/Permit Number: D19-0379 17 Response to Incomplete Letter # Response to Correction Letter # 1 n Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner El Deferred Submittal # Project Name: Sumi Korean Grill Project Address: 17250 Southcenter Pkwy Suite 148 Contact Person: NOS f\M-fairy Phone Number: W 6 - 5 21. 9 32- 5 Summary of Revision: Re\tt sioNs5 ecgta_ess p-i-vi- see si-tee7 AZ. REpo-Nr-S-0 iv -Eke t2Pfri e tsrA RECEIVED CITY OF TUKWILA PERMIT CENTER Sheet Number(s): Ac2- ( A "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Lil Entered in TRAKiT on CAUsersTatchStudio \DesktoptRevision Submittal Fonn.doc Revised: August 2015 C D CONSTRUCTION DESIGN LT 0 Some online services are currently uliavailable See a list of service outages. (finos://lni.wa.goviagency/systern-status) Page 1 of 2 17;;C)78-'in7usTr e—s htt Ds://in i.wa.gov) C D CONSTRUCTION DESIGN LLC Owner or tradesperson Principals ZHAO, LONG, PARTNER/MEMBER HUANG, JUNCHENG, PARTNER/MEMBER Doing business as C D CONSTRUCTION DESIGN LLC WA UBI No. 604 263 987 14150 125TH AVE NE KIRKLAND, WA 98034-1529 206-466-9753 KING County Business type Limited Liability Company Governing persons JUNCHENG HUANG LONG ZHAO; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no, CDCONDC823N8 Effective — expiration 08/29/2018— 08/29/2020 Bond Western Surety Co Bond account no. 63735852 $12,000.00 Received by L&I Effective date 08/29/2018 07/24/2018 Expiration date Until Canceled Insurance ..... „ Berkley Assurance Company $1,000,000.00 Policy no. VUMB0181571 Received by L&I Effective date 08/05/2019 08/06/2019 Expiration date 08/06/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations 691 elg.) No license violations during the previous 6 year period. haps://secure.lni.wa.gov/verify/Detail.aspx?Uffi=604263987&LIC=CDCONDC823N8&SAW= 2/27/2020 ABBREVIATIONS PROJECT STATISTICS A L ACCES ACH ACCESSORY ABOVELCOUNTER HEIGHT LAN LOCALTAREA NETWORK LAM LAMINATE ACT ACOUSTICALICEILING TILE LAV LAVATORY ADA AMERICAN'S A WITH LB POUND DISABILITIES! ACT LT LIGHT ADJ ADJUSTABLE LRV LIGHT REFLECTANCE VALUE AFF ABOVESFINISHEDDFLOOR AL ALUMINUM M ALT ARCH AUTO ALTERNATE ARCHITECT(URAL) AUTOMATIC MAX MAXIMUM MDF MEDIUM —DENSITY FIBERBORAD AVG AVERAGE MFD MANUFACTURED AND MFR MANUFACTURER AT MECH MECHANICAL B MED MEDICAL MET METAL BLDG BUILDING MIN MINIMUM BD BOARD MISC MISCELLANEOUS BLKG BLOCKING MLWK MILLWORK C MOIST MOISTURE MTD MOUNTED CAB CPT CABINET CARPET MTL METAL MW MICROWAVE CEM CEMENT(ITIOUS) CLG CEILING CLR CLEAR MIR MIRROR N CONC CONCRETE NIC NOT IN CONTRACT CONT CMU CH CONTINUOUS(ATION) CONCRETE MASONRY UNIT CHAIR NO NUMBER NTS NOT TO SCALE N2O NITROUS OXIDE CTOP CTC CW D COUNTERTOP CENTERCTONCENTER COLD WATER 0 OC ON CENTER OVHD OVERHEAD OP OPERATORY DBL DEMO DEPT DET DOUBLE DEMOLITION DEPARTMENT DETAIL P P PAINT PNL PANEL DF DIA DIFF DIM DISP DIV DN DR DRINKIN.O.NEOUNTAIN DIAMETER DIFFUSER DIMENSION DISPENSER DIVISION DOWN DOOR PORT PORTABLE PREFAB PREFABRICATED PLAM PLASTICILAMINATE PLAS PLASTER PLYWD PLYWOOD R RAD RADIUS SITE ADDRESS : CODES USED : 17250 SOUTHCENTER PARKWAY SUITE #148 TUKWILA, WA 98188 2015 INTERNATIONAL BUILDING CODE (STATE OF WASHINGTON AMENDMENTS) 2015 INTERNATIONAL EXISTING BUILDING CODE (PRESCRIPTIVE METHOD, CHAPTER 3) (STATE OF WASHINGTON AMENDMENTS) 2015 INTERNATIONAL MECHANICAL CODE 2015 UNIFORM PLUMBING CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 WASHINGTON STATE ENERGY CODE ICC A117.1 2009 (ACCESSIBILITY CODE) CITY OF TUKWILA LOCAL AMENDMENTS AND REGULATIONS PARCEL NUMBER: LEGAL: PLAT LOT: GROUP OF OCCUPANCY: SPRINKLER: NUMBER OF STORIES: ZONING: YEAR BUILT: PROPERTY SIZE: BUILDING SIZE: BUILDING HEIGHT: SUITE AREAS: CONSTRUCTION TYPE: PARKING REQUIRED: DEFERRED SUBMITTAL: CONSTRUCTION COST: 788892-0020 SOUTHCENTER SQUARE BSIP PARCEL 2 B YES (FULLY SPRINKLED) 1 TUC 2007 51,6516 SF 11.86 ACRES 46,426 SF +/-22" (VARIES) 1850 SF. I I—B ALL EXISTING FOR ALLOWABLE USES MECHANICAL, FIRE ALARM, SPRINKLERS. $150,000 DW DISHWASHER DWR DRAWER REFLECTEDACEILING RCP PLAN REF REFRIGERATOR PROJECT TEAM El FC FNGR ENTR EQ FLECTRICAI ENGINEER(ED) ENTRANCE EQUAL REQ REQUIRE(D)(MENT) REINF REINFORCE(D) (ING)(MENT) REV REVISION RM ROOM RO ROUGHLOPENING EQUIP EXIST.E(E) FXPS FXT EQUIPMENT EXISTING EXPOSE(D) EXTERIOR RP RR RESINBPANEL RESTROOM SCR SCRIBE SECUR SECURITY FAB FF FIN FPLC FR FRMG FIR FCIC FOIO FOIC FURN FS FRP G FIXED FABRIC FINISHFDIFND FINISH FIREPLACE FIREPRAT(ING)(ED) FRAMING FLOOR(ING) FURNISHED & INSTALLED BY CONTRACTOR FURNISHED & INSTALLED BY OWNER FURNISHED BY OWNER INSTALLED BY CONTRACTOR FURNITURE FLOOR SINK FIBERGLASS REINFORCED PLASTIC SF SQUARETFEET SIM SIMILAR SPEC(S) SPECIFICATION(S) SS SOLIDBSURFACE STD STANDARD STL STOOL ST STONE STRUCT STRUCTURAL SURF SURFACE RESTAURANT OWNER : LANDLORD: DESIGN TEAM: ARCHITECT : STARDUST HOSPITATLITY LLC SYLVIA TEL: 702-526-6978 WIG PROPERTIES DAVID KRUEGER TEL #425-641-2044 CATCH DESIGN STUDIO 1405 BOYLSTON AVE. SEATTLE, WA 98122 CONTACT: NOS NARIN TEL: 206.322.4323 E-MAIL: NOS@CATCHSTUDIO.COM THAN SUTAN: SENIOR ARCHITECT THAN@CATCHSTUDIO.COM LEGEND SV SITETVERIFY SYS SYSTEM(S) SLB SLAB STN STAIN T TIL TILE TBD TO BE DETERMINED TEX TEXTILE BUILDING SECTION WALL OR DETAIL SECTION BUILDING SECTION NORTH ARROW THK THICK GA GL GWB GYP GR GAUGE GLASS GYPSUMEWALL BOARD GYPSUM PRINTED GRAPHIC TI TENANT IMPROVEMENT TBL TABLE TRANS TRANSPARENT TYP TYPICAL TV TR TELEVISION TRIM DET SHT DETAIL SECTION (NONDIRECTIONAL) CENTERLINE SOUTHCENTER PKWY SOUTHCENTER SQUARE 17100, 17150, 17200, & 17250 Southcenter Parkes: Tukwila, Washington 98188 WIG BOULEVARD DSW H ER SHOE WAREHOUSE I E,c 111( PARKING TRAVET ° I TANCE. PARGNG NL) ADDERS TOTAL BUILDING AREA TOTAL PARKING - MONUMENT SIGNS - 2-SIDED MONUMENT SIGNS - DISPLAY WINDOWS TOTAL SIGNS ON PROPERTY: 5 E D SCOPE OF WORK: TENANT IMPROVEMENT - INTERIOR ALTERATION FROM PIZZA RESTAURANT INTO A NEW KOREAN BBQ RESTAURANT, INSTALLING NEW COMMERCIAL KITCHEN EQUIPMENT, INTERIOR PARTITION WALL AND FINISHING WORK. DRAWING INDEX HD HDWD HDWR HM HORIZ HR HW HT HVAC HEAD HARDWOOD HARDWARE HOLLOWOMETAL HORIZONTAL HOUR HOT WATER HEIGHT HFATING,AVFNTILATING, ANDTAIR,CONDITIONING U UTIL UTILITY UNO UNLESS NOTED OTHERWISE V VAC VACUUM VERT VERTICAL VFY VERIFY VIF VIN W VERIFYAIN FIELD VINYL 0 FIRST FLOOR EL. 100'-0" ENLARGED DETAIL REFERENCE ELEVATION TARGET EXTERIOR ELEVATION INTERIOR ELEVATION 0 FIRST FLOOR PLAN 1/8" = 1'-0" DRAWING LABEL GRAPHIC SCALE BREAK LINE REVISION CLOUD AND NUMBER OFFICE 046 ROOM NAME AND ROOM NUMBER +101,0" SPOT ELEVATION INFO INSUL INT J INFORMATION INSUI ATION INTERIOR WC WB WITH WATERYCLOSET WALLIBASE WD WOOD WH WATERAHEATER JAN JANITOR WOD WASHERCLODRYER WAO WITHOUT WT WEIGHT ACT CEILING TYPE CEILING HEIGHT CEILING HEIGHT WINDOW NUMBER ALIGN ALIGN NOTE COLUMNS GRID AND BUBBLES CS1 Al A2 A3 A4 A5 A6 P1 P2 : VICINITY MAP, SITE PLAN : EXISTING PLAN DEMOLITION PLAN : FLOOR PLAN : FRAMING PLAN/ DETAILS : REFLECTED CEILING PLAN/ DETAILS : ELEVATION A-D : BBQ VENT TABLE AND DISH WASHER SPECIFICATIONS : WASTE AND VENT RISER PLAN : POTABLE WATER RISER PLAN DEFERRED SUBMITTAL KIT +46„ KITCHEN WP WEATHER PROOF INDICATES HEIGHT ABOVE FINISHED FLOOR OR ABOVE FINISHED GRADE TO TOP OF DEVICE. DOOR NUMBER WALL TYPES MECHANICAL (HVAC) MECHANICAL KITCHEN HOOD SPRINKLER / FIRE ALARM 229,968 SF 924 STALLS MINKLER BOULEVARD IT SITE PLAN SITE LOCATION ; VICINITY MAP SCALE : NTS SEPARATE PERMIT REQUIRED FOP.: 1c7 PlotTtcrir'1g Gas PiOriy City of Tukwila ;OWING DIVISION ., A JAN 0 8 ?020 PERMIT CENTER SCALE : NTS DESIGN STUD 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM ARCHITECT: 6192 REGISTERED ARCHITECT THAN SUTAN STATE OF WASHINGTON PROJECT TITLE: SUMI KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: PROJECT STATISTICS VICINITY MAP SITE PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 01/02/20 SHEET# CS1 DESIGN STUDIO Cr ) 39'-5" 14'-5" 12'-4" EXISTING FLOOR PLAN SCALE : 1/4" = 11-0" <0 X 0,1 X CO CC CD rn CD rn 1- 39'-5" 0 —lc) 14'-5" 12'-4" I:T:7171M 1 DEMOLITION PLAN SCALE : 1/4" = 11-0" 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX, 206.322.9177 90-7E-MAIL:INFO@CATCHSTUDIO.COM 13-11" VVWW.CATCHSTUDIO.COM 36" '-3" „----- • 1„1t, -1 (E)3 COMP. SINK (E)FD (E)FS - A _ 31Y-2" (E)WALK IN COOLER (E)FS: E ) VVALK IN FREEZER (E)FD (E)MEN'S RESTROOM 81'L9" , 90'-6" 90'-7" 13'-11" 36'-3" INREDIENTS COUNTER cr) (E)MOP SINK WITH WATER HEATER ABOVE up CT) 6r) Et.? (E)FD (E)WOMEN'S RESTROOM \ / / \ / / I- t., ,.. w . Z ti c`f- __Y (E)3 COMP. SINK (E)FD (E)FS 30'-5" (E)WALK IN COOLER (E)WALK IN FREEZER (E)MEN'S RESTROOM (E)MOP SINK WITH WATER HEATER ABOVE . -- ------ cr) (E)FD (E)WOMEN'S RESTROOM 82'-2" 7'-11" 90'-6" RECEIVED CITY OFVLA JAN 08 2020 ARCHITECT: 6192 REGISTERED ARCHITECT THAN SUTAN STATE OF WASHINGTON PROJECT TITLE: SUMI KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: EXISTING PLAN DEMOLITION PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE -AS -NOTED- r- FILEi of 1-u Rtitt„.[J,-\[ DATE: 01/02/20 SHEET# DL 14 PE IT NTER A SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". Lu zi Z Z LU INSTALL ACCESSIBLE EXIT SIGN. INSTALL MAXIMUM OCCUPANCY LOAD SIGN \ 6-3 3' NEW SHORT WALL 40" A.F.F. TABLE 2X36 0'-4" 2'-9" , SEATING . SEATING IBIIX20' 18X20' DUCT CLEAN OUT ON DUCT CLEAN OUT ON EACH BRANCH DUCT , EACH BRANCH DUCT MAX. 12 FT. BY OTHER MAX. 12 FT. BY OTHER 39'-5" SEATING 1-8 18IX20" SEATING 18X20" SEATING ' 18120" -- DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. BY OTHER SEATING I SEATING 18''X20" Lan 18X20" reaCZZais 5.-8" TABLE 160X36 I ACCE 46 SEATS NEW FLOOR PLAN [ SCALE : 1/4" = OCCUPANCY LOAD: 1,850 SOFT. TOTAL TABLE 60X36 50" DINING AREA 1 210 SO FT IS INET) .14 OCCUPANTS TABLE ]60X36 EMERGENCY EGRESS PATH MIN 44" WIDE TYP, ; TABLE 48X36 2' E PATH OF TRAVEL - GREATEST DISTANCE TO EXIT = ABLEI 2X36 111TABLE 52X36! 5'-8" 480 SO FT 15 (IlE) =32 OCCUPANTS -- TABLE 52X36 37'-8.Z" TABLE 52X36 ROOM NAME FLOOR AREA OCCUPANT LOAD FACTOR OCCUPANT LOAD 1. DINING AREA 1 2. DINING AREA 2 3. KITCHEN AREA 5. PREP STORAGE AREA 210 S.F. 480 S.F. 259 S.F. 449 S.F. 15 (NET) 15 (NET) 200 GROSS 200 GROSS (DINING) (DINING) (KITCHEN) (KITCHEN) 14 32 1 2 TOTAL OCCUPANT LOAD: 49 DOOR SCHEDULE 5'-8" TABLE 52X36! ABLE -!"! 2X36 HUGS EXHAU T • ENCLOSURE SERVICE STATION I boo EXI HAUST IP61 9'-6" el- ;!! Lu 3'-3" cc OMR COUNT CC 11.1 CC N- U,SC LLJ LA Co 90'-7" 13-11" 2'-112" 3'-8" 6'-8" ' ^ " 82'-2" LEGEND : EQUIPMENT LIST (E) (N) EXISTING WALL NEW SHORT WALL 46" A.E.E. 3 5/8" MTL. STUD 20GA. 16" O.C. W4 TYPE "X" GWB BOTH SIDE NEW SHORT WALL 40" A.F.F. 3 5/8" MTL. STUD 20GA. 16" O.C. \t,' W/TYPE "X" GWB BOTH SIDE NEW FULL HEIGHT WALL 4" MTL. STUD 20GA. 16" O.C. \ W4 TYPE "X" GWB ONE SIDE EXISTING Z. 'FS FLOOR SINK NEW (.0FD FLOOR DRAIN PREP/ KITCHEN AREA 259 SO PT I USA ,S999999) =1 OCCUPANTS SODA b MACHINE 040 WATER a DISPENSER - /HS. Ty_ SUPPLIER CU F- 2 I 4 3 ! X 40 It! LA 2 ONE COMP, SINK X I 1 SODA MACHINE DESCRIPTION - SHELF 48" ----- GRILL PAN CLEANING STATION --- SHELF 48X12" I (N)VEG SINK W/ 48" A.F.F. BARRICADE (E)MEAT SIN 1 COMP. SINK TABLE 30"X36" PI3(E)FD RICE I ,z * • .. AI'. *JY • .. ... * ''',.,„, 4,6_) OOKER OM, 1.1,1 NAM keRIMI ixviv ovivri 312. WPM OS. .11:411J ACCESSIBLE PATH OF TRAVE L GREATEST DISTANCE TO EXIT = 36'-3" DIRTY DISH CHEMICAL STORAGE BELOW - SHELF 48"X12" - SHELF 24"X12" tS•-•=7,T DISH WASHER CLEAN TABLE PREP/STORAGE NINA PT) 20 ,SERVICE) .2 OCCUPANTS (E)WALK IN COOLER 30'-5" EMERGENCY EGRESS PATH MIN 44' WIDE TYP, ACCESSIBLE PATH OF TRAVEL GREATEST DISTANCE TO EXIT 7-, 98'-(1" 42'-2" MANUFACTURER MODEL NUMBER DIMENSIONS (W.XD.XH.) 1 WORKING TABLE 48"X30" 4 ; X 1 ! POS ;STEELTON #522C512424 (30"X30"X44") I!I- IIREGENCY #600TB3048G (48"X30"X34") BY OTHER -- SHELF 24"X12" r(3,1,11.5 raM11. Braftla siCIA NNW (E)FS rE')WALK IN FREEZER NeKkee eft99, OR* (E)FD (E)MEN'S RESTROOM ELECTRICAL I PLUMBING GAS OD ! I 0 0 0 . C.) ,17 1/2" - 1/2" -1 1/2" "Hr 1/2" 111/2" INDIRECT BTU NOTES 5 X 6 ; X 1 SANDWICH COOLER 36" AVANTCO #SS-PT-36-HC "xD31"x H42") 1 SANDWICH COOLER 7 1 X , 1 UNDER FREEZER 48" lAVANTCO #SS-UC-48R-HC "xD30"x H39") 8 !x 1 : WORKING TABLE 18"X30" REGENCY #600TB3018G (W18"xD30"x H34") ] -t- 9 X I 1 8 BURNER /OVEN VULCAN #48S-8BN (W48"xD34"x H58") ..., _L 10 X , 1 , GRILL 24" WITH STORAGE BASE I CPG 300 MODEL #24CBRSBNL (W24"xD27"x H41") 1 TYPE I HOOD 8' IBYOTHER 12 IX, 1 , RICE COOKER 40 CUP PANASONIC SR-GA721( 21")(21"X0") 4.6 1 1/ 5 ! 115 2,9 115 NEMA 5-15P !NEMA 5-15P 275,000 DR# WIDTH 001 0'-6" HT THK. DOOR MAT/FIN. DOOR TYPE REMARKS 8'-0" I 1-3/4" ALUM. FRAME/W GLAZING 002 3'-0" 6-8" 1-3/4" SOLID CORE WOOD 003 3'-0" 6'-8" 1-3/4" SOLID CORE WOOD A* B (EXISTING) EXTERIOR DOOR ; MAIN ENTRANCE HARDWARE GROUP KEY NOTES 1,3,5,9,11,12,13 004 3'-0" 8'-0" 1-3/4" ALUM. FRAME/W GLAZING C * * THIS DOOR SHALL HAVE A SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." (EXISTING) INTERIOR DOOR POSTED MEN'S RESTROOM 6, 10, 14 (EXISTING) INTERIOR DOOR POSTED „C: MEN'S RESTROOM (EXISTING) EXTERIOR DOOR , EMERGENCY EXIT 6, 10, 14 1,3,5,9,11,12,13 1) ALL DOORS REQUIRED FOR ADA COMPLIANCE TO BE FITTED W/ APPROVED LEVER -TYPE HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. 2) MAX.1/2" THRESHOLD A.F.F. ROOM FINISH SCHEDULE • ROOM WALL CEILING FLOOR MAIN DINNING AREAS GYPSUM WALLBOARD/ LAMINATE/ PAINT T-BAR CEILING WOOD LAMINATE FLOOR 3 I SERVICE AREA COVED BASE GYPSUM WALLBOARD/ LAMINATE/ PAINT DRYWALL CEILING NON -SLIP CERAMIC TILE 4" TILE BASE 4" TILE BASE COUNTER STAINLESS STEEL STAINLESS STEEL / QUARTZ 4 RESTROOM WALL TILE DRYWALL CEILING I NON -SLIP CERAMIC TILE 4" TILE BASE WATER RESISTANT GWB BEHIND PLUMBING FIXTURES 5I KITCHEN / PREP AREA T-BAR CEILING NON -SLIP CERAMIC TILE 8' FRP AROUND WALLS TYP. DOOR NOTES 1. FINISH ALL WOOD DOOR! WITH CLEAR COAT SUITABLE FOR EXTERIOR USE 2. DOORS WITHIN THE PATH OF TRAVEL FOR HANDICAPPED TO BE OPENABLE WITH A SINGLE EFFORT BY LEVER, PANIC BAR OR PUSH/PULL HARDWARE. 3. EXIT DOORS TO BE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 4. DOOR CLOSERS TO BE ADJUSTED TO PROVIDE FOR A MAXIMUM EFFORT TO OPERATE OF 15 LBF. 5. THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT 6. BOTH SIDES OF DOORS SHALL BE FINISHED THE SAME, UNLESS OTHERWISE NOTED 7. ALL LEGAL EXITS SHALL BE PROVIDED WITH SELF-ILLUM EXIT SIGNS HAVING 6" LETTERS WITH 3/4" STROKES IN CONTRASTING COLORS. HARDWARE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER HARDWARE INCLUDING BACKSETS, STRIKES, ETC. 9. THE OPENING FORCE FOR ACCESSIBLE EXTERIOR DOORS SHALL NOT EXCEED 8 1/2 POUNDS FORCE. 8. HARDWARE GROUP KEY NOTES 1. PANIC HARDWARE 2. PUSH BAR 3. EXTERIOR PULL HANDLE 4. INTERIOR PULL HANDLE AND PUSH PLATE 5. COMMERCIAL UNLOCKED INDICATOR 6. PRIVACY, LEVER OPERATED HARDWARE 7. KEYED LOCKSET (SECURITY) 8. RIM CYLINDER LOCK 9. CLOSER 10. KICK PLATE 11. WEATHER STRIP 12. THRESHOLD 13. TOP & BOTTOM PIVOT 14. HINGE 6" TILE BASE SPECIFIED MAX. ON ALL SIGNS SEE Al. ON FLOOR PLAN QUARTZ STAINLESS STEEL MAXIMUM OCCUPANCY NOT TO EXCEED PERSONS ASSEMBLY OCCUPANCY WITHIN THE BUILDING SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE SCALE : A OCCUPANCY LOAD SIGN N.T.S. . 13 X 1 RICE WARMER 40 CUP PANASONIC SR-GA721'. 21"X21"X0") 14 X 2 i WORKING TABLE REGENCY #600ES2424G (24"X24"X24") 2500 10 56 ) 10 • 15 ' 1 X 5 ' WIRE SHELVING 54x18 t ---1 16 I i X 2 WIRE SHELVING 36x18 17' I ' X ' 1 WALL MOUNTED HAND SINK 18 1 x , 1 WORK TABLE 24"X30" . REGENCY #600TB3024G (24"X30"X34") - L--- --] 19 I X : 1 WALL MOUNTED HAND SINK 20 X 21 X 80,000 - 1 COMP. SINK (VEGGIES) BLUE AIR COMMERCIAL #BSP-18 (39"X24"X44") DRAIN BOARD LEFT WITH SPLASH BARRICADE ! 1 COMP. SINK (MEAT) 1 DRAIN BOARD RIGHT WITH SPLASH BARRICADE ! BLUE AIR COMMERCIAL #BSP-18 /R (39"X24"X441 22 23 X X WORKING TABLE 24x60 REGENCY #600TSB2460S (24"X60"X34") 1 SPRAY NOZZEL FAUCET 24 X ! I 1 WORKING TABLE 30"X36" REGENCY #600FPRSFA12K REGENCY #600TSB3036S (30"X36"X34") 25 . X : 1 I30MPS< DRAINBOARD LEFT 26 I X . I 1 DISHWASHER CORNER UNIT 27 XI 1 CLEAN DISH TABLE 2' 28 ' • X ! 1 ! EMPLOYEE LOCKER 29 ! • X 1 MOP SINK 30 • X 1 HOT WATER TANK 31 x 12 I WALL MOUNTED SHELVING 32 I X 1 ! WALK IN FREEZER 33 X 1 WALK IN COOLER 34 x 35 x 36 Ix AUTO-CHLOR A4 WATERSAVER REGENCY #600CDT24 (24"X30"X44") BY OTHER REGENCY #600WS1248 (24"X48") ; 1 ; HOT WATER DISPENSER , BUNN #02500.0001 (7"X14"X24") 1 WORKTOP COOLER 60" AVANTCO #SS-WT-60R-HC (60"X30"X3 1/2" 1/2" , 1 1/2" -1] 1/2" i 1/2" :1 1/2" ; ----------------- 1/2" 1/2" 1 1/2" ' - ;INDIRECT 1/2" 1/2" 1 1/2" 1 INDIRECT ] 1/2" 1/2" ; 1 1/2" 1/2" 1/2" 1 1/2" 1/2" 1/2" 1/2" 1/2" ! 1/2" 1 1/2' 1/2" 1/2" 1 1/2" 1800 I 15 120 1/2" 1/2" ! 1 1/2" 1 FAUCET T&S #B-0211 (12") NOTE: IBC 1013.4, "RAISED CHARACTER AND BRAILLE EXIT SIGNS" lk SIGN STATING EXIT IN VISUAL CHARACTERS, RAISED CHARACTERS, AND BRAILLE, AND COMPLYING WITH ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY OR RAMP, AN EXIT PASSAGEWAY, AND THE EXIT DISCHARGE. B RAISED CHARACTER AND BRAILLE EXIT SIGNS SCALE: N.T.S. 2.9 1/5 115 TABLE 1006 2 1 SPACES WITH ONE : • - OR I - - ^ ' . -.•!- OCCUPANCY MAXIMUM OCCUPANT LOAD OF SPACE MAXIMUM . I"," ' . -" 8, - ICI,- 'L - DISTANCE (Tee() Without SprInkler System tfeet) - . 1 With Sprinkler System l iteetl OLS30 OL L 30 "-- - -,--, - . •!, 2E - " ,.-:• -8 - - . . - . _ . DIRECT CONNECT TO 'GREASE LINE INDIRECT 1NEMA 5-15P 1/2" 1/2" 1 1/2" 275000 ------- SHELF 48"X12" EMPL LOCKE YEE RS cE/CO2, • CANISTER (E)SODA RACK !! ] kr'rit c;.) (E)MOP SINK WITH WATER HEATER ABOVE) • (E)WOMEN'S RESTROOM 0 (E)ED 7'-11" J&S Proline, tnc. Cl4j),, 2426 NV 80 Street, #201 LA, CA 90057 TEL : 818-355-0501 www.,jsproline.com JSDR-300 Manual JSDR-300 Round Down -Draft Roaster NOTES FOR HEALTH DEPARTMENT: NOTE: ALL GLAZED DOORS TO HAVE .60 U-VALUES AND .45 SHGC VALUES NO CHANGE ON EXTERIOR WINDOWS SHELVING: REFRIGERATORS: STAINLESS STEEL STEEL SHELVES; DRY STORAGE: LAMINATE/ WOOD; DRYING RACK: STAINLESS STEEL; CHEMICALS SHELVING: WIRED RACK ALL PAINT IN KITCHEN, PREP. AREA, AND SCULLERY AREA IS SEMI -GLOSS. THERE'RE NO UNNECESSARILY EXPOSED UTILITIES. BE ADVISED THAT THE NEW WASHINGTON STATE FOOD CODE REQUIRED COMMERCIAL REFRIGERATION TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW (DOWN FROM 45 DEGREES) FULL HEIGHT STAINLESS STEEL PANEL WALL BEHIND COOKING LINE, TYP. 4-0" HEIGHT FRP PANELS AROUND KITCHEN WALL, TYP. EXHAUST HOOD SYSTEM & FIRE SUPPRESSION SYSTEM BY OTHERS 5% OF THE SEATING SHALL BE ACCESSIBLE AND DISPERSED THROUGHOUT THE DINING AREA. SHOW FOR ACCESSIBLE SEATING SPACES ASSEMBLY OCCUPANCY WITHIN THE BUILDING SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE PLUMBING NOTE: PLEASE NOTE THAT THE FOLLOWING FIXTURES MUST DISCHARGE INTO THE GREASE INTERCEPTOR - KITCHEN FLOOR DRAINS - DISHWASHER - 3 COMPARTMENT SINK - MOP SINK - DUMP SINK - MEAT SINK DESIGN STUDIO STUDIO 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAILINFO@CATCHSTUDIO.COM VVWVV.CATCHSTUDIO.COM ARCHITECT: 6192 REGISTERED ARCHITECT THAN SUTAN STATE OF WASHINGTON PROJECT TITLE: SUM! KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: FLOOR PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: nEcEivED CITY OF "i JAN 08 2020 PERMIT CENTER -,44 DATE: 01/02/20 SHEET# 7. BBQ Grill with Exhaust Hood Data Product Name BB() Grill with Exhaust Hood Model No JSDR-300 Out Box Size Diem Appearnce Dimension 540 x 400 x 280mm 14.7(374mm) Heigbt Weight Table hole size 1 0.6" ( 270m m 26.3LBS(12kg) 14.1"(380mm) GAS Input Gas Supply Pressure Gas Connection Natural 8,200Btu Propane I 0.22kg/h Natural MIN 5"WC, MAX 7" . Propane . MIN 10"WC, MAX 13" 1/2 Flare Gas Electrical Voltage D/C 1.5v .Minimum Air Flow Rates 110CFM Exhaust Hood Minmum Exhaust Flow 110CFM Filter type I Baffle Fiter, 9" x9" 1EA Exhaust Hood Electrical Voltage 115v 1 Gas Regulator Not Included Uae CSA Certified W/40,000Btu Capacity Manifold Pressure Natural Propane Supply Line Choung Dong Gas Tech Co. Product Company Name 433715 Yu Isaeng Ri Dee Got Myun Kim Po -City Kyung Xl Do KOREA. TEL:82-31-98715764:5 7"WC 10"WC Manual cut off MUSTS#6 I Install Manual Valve Upstream] J&S Proline, Inc. 2426 W 8" Street, #201 LA, CA 90057 TEL: (818) 355-0501, FAX: (424) 772-1425 www.jsproline.com 8. Exhaust Hood Operation Manual This BBQ Grill with Exhaust Hood is recommended for Commercial Cooking. This hood is provided with the appropriate Filter Unit. The classification:Filter type hood with one Baffle filter Replacement Filter:Stainless Steel Baffle filter /1EA Col'o 0.111101d tow-LI prow,LL,L, ,F tre typ, F8tirc rn;3C,1371,-,1,, , b,„„ ;, Ti' Minimum air flow rates and minimum exhaust flow:110 CFM Air flow rates were established under controlled laboratory conditions. aiLi rian faux du: I t Installation shall be in accordance with NFPA96(1orUSAjand ULC S650(for Canada). L ,,LtLLS-yro, , MI -PA L1Z,5 JES Proline, Inc. 2426 W 8FiStreet, 4201 LA, CA 9005 Tel: 818-355-0501 Manufacture:Choung Dong Gas Tech Co. Made in Korea, l&SR.p.Pyroclaionoenialnc. 01, LISTED Product: Down draft BBQ Grill Model No: JSDR-300 Serial No * GAS INPUT: NATURAL 8200Btu * GAS SUPPLY PRESSURE: 5" WC * MANIFOLD GAS PRESSURE: 5" W.0 Intended for other then houshold use. (Non destine a usage dorrestique) For use in noncombustible locations Only, OvstI,er, el,, El,,'or,ux de re,-,,,,,, mr,enbstIble, sP,Imen,i OPERATING INSTRUCTIONS 1. Please read the user manual before using the Roaster. 2. Please wait about 5 minutes when reignition the Roaster. 3. Please keep inflammables away from unit during use. 4. Please make sure middle valve is locked when unit is not in use. 5. If the unit is defective, Please contact your supplier right away. Any disassembling or alteration of product will void warranty. 2426 W 8" Street, 0201 LA, CA 90057 TEL: (818) 355-0501, 818-568-8822, FAX (424)772-1425 Made by Choung Dong Gas Tech. Co. KOREA 53'-9" 90'-7" 36'-3" YAWcCIXI 6'-3" FRAMING PLAN SCALE : 1/4" = 11-0" 33-2'21" 34'-1& 27-11" TYP. INTERIOR WALL ASSEMBLY: COUNTER TOP PER SCHEDULE 6" METAL STUDS @ 16" O.C. WITH 18" 5/8" TYPE X GYP. BD. / 1 3 / ON BOTH SIDES - TAPED, SANDED )41", 7 4" 6 4" SMOOTH, PAINT GRADE FINISH (TYR) MOISTURE RESISTANT 58" GREEN BOARD EIS AT WET AND MOISTURE AREAS = \ C\I\ I 32-10" COUNTER FACE PER ELEVATION FLOOR TRACK TO BE ANCHORED TO EXISTING CONC. SLAB W/ POWER DRIVEN FASTENERS AT 20" O.C.-(TYP.) FINISH FLOOR AS SPECIFIED NEW PASS THROUGH COUNTER THE TOPS OF TABLES COUNTER AND WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM FROM THE FLOOR OR GROUND. MIN. CLEARANCE: TOE 11", KNEE 8" Ce) 4,444 !„„:4444.444 „, 1 44444 44. /y I ! 4.74-4-441 4_4 / ! ( I : , 4444441/ , !„... SCALE : N.T.S. SCALE: N.T.S. HOOD EXHAUST ENCLOSURE ,4! 1'-8" 1'-8" 3.-241" HOOD EXHAUSt ENCLOSURE TYP. INTERIOR WALL ASSEMBLY: 4" METAL STUDS @ 24" 0.C. WITH 5/8" TYPE X GYP. BD. ON BOTH SIDES TAPED, SANDED SMOOTH, PAINT GRADE FINISH (TYP.) NN FLOOR TRACK TO BE ANCHORED TO EXISTING CONC. SLAB W/ POWER DRIVEN FASTENERS AT 24" O.C.-(TYP.) RUBBER COVE BASE - CV, CC L11 = f— CO , *Cr! cD = = 0 cc Eo cc, vt!— Cn CID I— Lu Cn z .4r 44,4\ \ I / • , 6'-8" 13-11" / TOP/W 3/4" FINISH WOOD COVING MOISTURE RESISTANT 8" GREEN BOARD E/S AT WET AND MOISTURE AREAS EXISTING CONC. FLOOR SLAB FINISH FLOOR AS SPECIFIED 2 NEW SHORT WALL DETAIL 59" DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. \ ) 24" 212" 20" • MIN. 1/4" PITCH PER FLOOR MIN. 16 GA. GALV. DUCT 5 BUILT IN BENCH DETAIL \ \ c\J C .Z.1" \ \ \ \ -- DUCT SCALE: SCALE : N.T.S. TABLE MODEL:FSDE-400 DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. 46'-84'" CONT. 20 GA. TOP TRACK -44 I , . , 1 , , 1 I , 1 , 1 , , 1 . . 1 , 1 1 1 , 1 , „ • ' '!-'1, ' ". LEGEND : (E) (N) EXISTING WALL NEW SHORT WALL 46" A.F.F. /44, 3 5/8" MTL. STUD 20GA. 16" 0.C. 44 4,12 WI TYPE "X" GWB BOTH SIDE NEW SHORT WALL 40" A.F.F. 3 5/8" MTL, STUD 20GA. 16" O.C. W4 TYPE "X" GWB BOTH SIDE NEW FULL HEIGHT WALL /7 4" MTL. STUD 20GA. 16" O.C. 3 A 4/ W446 TYPE "X" GWB ONE SIDE EXISTING NEW EXISTING ROOF STRUCTURE TYP. INTERIOR WALL ASSEMBLY: 4"-6" METAL STUDS @ 20" O.C. WITH 5/8" TYPE X GYP. BD. ON BOTH SIDES - TAPED, SANDED 44/ SMOOTH, PAINT SANDED SMOOTH, PAINT / GRADE FINISH (TYP.) FLOOR TRACK TO BE ANCHORED TO EXISTING CONC. SLAB W/ POWER DRIVEN FASTENERS AT 16" O.C. (TYP.) 3 COVE BASE ATTACH TO EXISTING BUILDING STRUCTURE TO MATCH EXISTING. MOISTURE RESISTANT 5/8" GREEN BOARD E/S AT WET AND MOISTURE AREAS FINISH FLOOR AS SPECIFIED TYP.NEW INTERIOR FULL HEIGHT WALL MIN. 1/4" PITCH PER FLOOR MIN. 16 GA. GALV. DUCT UNIT BODY SET CONTROL BOX DOOR PANEL DOOR PANEL FILTER BOX SCALE: N.T.S. RAIN CAP IF NEEDED \ METAL - \\ STUD \-„ 5/8" SHEET ROCK LINED ALL AROUND EACH SIDE OF THE OPENING LIMH FS 7IFD FLOOR DRAIN SCALE: N.T.S. FLOOR SINK 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL, 206.322.4323 FAX, 206.322.9177 E-MAIL:INFO@CATCHSTUDIO,COM VVWW.CATCHSTUDIO.COM ARCHITECT: 6192 REGISTERED ARCHITECT THAN SUTAN STATE OF WASHINGTON TABLE 1020.1 - - PROJECT TITLE: CORRIDOR FIRE -RESISTANCE RATING OCCUPANCY OCCUPANT LOAD SERVED BY CORRIDOR REQUIRED FIRE -RESISTANCE RATING (hours) Without sprinkler system With sprinkler system' H-1,1+2, H•3 All Not Permitted 1 H-4, H-S, L R-1, R-2, R-3, R-31„ R-4 Greater than 30 Greater than 30 Greater than 10 Not Permitted 41' ,I1 1-2, Greater rhn Not Permitted 1-3, R-2,4 Greater th.75,7 Not Permitted 6 Greater than 40 - MTL 4" STUD @ 16" O.C. 20" 6" CONTINUOUS / UNPUNCHED STEEL TRACK (E) DEMISING WALL 16 GA. GALV. DUCT WELDED DETAILS DEFERRED SEPARATE MECHANICAL PERMIT FIRE RATED DUCT WRAP AS PER MECHANICAL PERMIT -- 5/8" TYPE X -GYP BD. EXTERIOR OF DUCT FRAMING .1 EXHAUST DUCT FRAMING DETAIL z------ ANGLE IRON SUPPORT ALL WELDED IL(E) ROOF - - 16 GA. GALV. DUCT WELDED FIRE RATED DUCT WRAP SCALE: N.T.S. SCALE: N.T.S. PEC4F4', fl CITY i4F .JAN 0 8 2o2 PERMIT CENTER SUM KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: FRAMING PLAN DETAILS REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FIUE 7474 "7 v' • , „ „. 4,1144447L- '4 4 4,4 4444, 444 DATE: 01/02/20 SHEET# A3 4 ADA TABLE DETAIL N.T.S. 6 HVAC TABLE DUCTING DETAIL 7 HVAC DUCT DETAIL EXHAUST TO ROOF Project Title: SHENG VAN GRILL FISH Date 10/12/2016 Calculation Area NOTE 9 « (7 Addition - (7 Addition stand alone - + existing « Spaces where < 50% of Spaces where a 50% of luminaires are replaced luminaires are replaced - For Building Department Use LPA Calculation Type (•I Standard (T) Additional Efficiency Package Option C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE, Location (plan #, room #) Space Type Ceiling Height NOTE z Gross Interior Area in ft` Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 1 Dining area: Family dining area 893 0,710 634 2 Restroom: all other 110 0,780 86 3 Food preparation 727 0.790 574 Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE e0 Total Area Retail Display 1730 LTG-INT-DISPLAY Allowed Watts Allowance from 1295 Location (plan #, room #) . Fixture Description NOTE 4,56 Number of Fixtures Watts/ NOTE 7 Fixture Watts Proposed C: PENDANT LIGHT 24 30 720 F: FLUSH MOUNT LIGHT 5 30 150 TRACK LIGHT 7 32 224 FLUORESCENT FIXTURE 4 15 60 RECESSED LIGHT 2 15 30 EXIT LIGHT 7 5 35 INTERIOR EMERGENCY LIGHT 10 5 50 EXTERIOR EMERGENCY LIGHT 2 10 20 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1289 Interior Lighting Power AllowanceCOMPL)ESI Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: SUMI KOREAN BBQ Date 11/22/2019 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use Company Name, SUMI KOREAN BBQ Company Address: 17250 SOUTHCENTER PKWY S #148 TUKWILA, WA 98188 Applicant Name: SYLVIA Applicant Phone: 702-526-6978 Applicant Email: Project Description _1 New Building ; j Addition , ] Alteration ['j Plans Included Include PROD -SUM form (included in envelope forms workbook) with lighting complliance forms. Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting --, S Exterior lighting - -- --------- �- Proposed Lighting in Proposed Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project - Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance ---- ---------- ❑ Addition is combined with existing: - - -- _ For interior lighting projects, include new + existing interior lighting fixture wattage in Wattage table in LTG-INT-BLD or LTG-lNT-SPACE form, For exterior lighting projects, include new + existing exterior lighting fixture wattage Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. Interior and Exterior Lighting Alterations g g eraon Select all Lighting Power and Lighting~ Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit maybe combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned perC4o8.3. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced —� -, 11 I L_ Less than 50% of existing are replaced a = --j .0 es.. ._m._.._.__ ....l to-remem fixtures span comply with total -to -remain L G-to-remain fixtures in Proposed LTG-EXT form. -to -remain fixtures shall not exceed the -remain fixtures in the Proposed Lighting form. and parking garages, and total -- Lamp and/or ballast replacement only existing total wattage not increased .......-_--.----_---- --_..u.gh...x. 50% a more replaced -Total lighting power LPAperWattage ableC40in L and T-BLO405. ,2. Lighting Wattage table in LTG-INT-BLQ Less than 50% replaced - Total lighting total lighting power prior to alteration. Include Wattage table in LTG-INT-BLD, LTG-tNT-SPACE 50% threshold applies to number of luminaires installed wattage for exteriorluminaires. - ---- ---- L. lunew + + existing Include new E or LTG-tNT-SPACE or power of new + existing new * existing -to or LTG-EXT for interior spaces Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) New or moved lighting panel Interior pace is reconfigured - tummaires unchanged or relocated only New wiring or circuit - For interior lighting, � provide required manual controls per C405.2.3, r occupancy n No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide alt applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use n Existing interior lighting systems in areas under -going a change in space use are upgraded to `-' comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. DESIGN STUDIO T-BAR CEILING 111r7 14'-6"A.F.F. FINISHED FLOOR 0-0" T-BAR CEILING g-6"A.F.F. E.0 PT,, DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. 1'-8" 4' ELEVATION - A SCALE: 3/8" = DRYWALL CEILING "IF 8'-6"A.F.F. FINISHED Er? 4' 22'-9" MIN. 1/4" PITCH PER FLOOR MIN. 16 GA. GALV. DUCT 7'-1" il 24" a _Li 2'-6" '-10" 1'-8" SEE DETAIL 5 PAGE A3 T-BAR CEILING 14'-&'A.F.F. k FINISHED 1117 FLOOR 0'-0" PT SOFFIT CEILING 8'-6"A.F.F. PASS THROUGH COUNTER SERVER STATION - „ PT co 1'-8" ELEVATION - B SCALE: 3/8" = 1-0" 17' 22'-9" 2'-5" 1'-8" SEE DETAIL 1 PAGE A3 18" FOOD LANDING SANDWICH PREP TABLE EJ B FRP 0'-17" SANDWICH PREP TABLE 0 E‘, S. 0 CLASS I HOOD 8'-0" BY OTHER SS PREP TABLE 48" 18" 48" 48" 20" 24" FRP`; '33 30'4" / 24" 000 e WORKING TABLE 30"X24" GRILL PAN CLEANING I Al ION GRILL PAN CLEANING I AlION WORKING TABLE 30"X36" RINSE WASH SANITIZE -t4 CLEAN TABLE N (E)STORAGE RACK 54"X18" 48" .FRP, (E)STORAGE RACK 54"X18" FLOOR 0'-0" T-BAR CEILING 14'-6"A.F.F. 1-5" 2-1" ELEVATION - C SCALE: 3/8" = 3'-1" 2'-11" 13-11" SEE DETAIL 7 PAGE A3 3'-7" 2'-3" DIRECT CONNECT TO EXISTING GREASE INTERCEPTOR 36'- FS 1 FINISHED - DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. TABLE MODEL:FSDE-300 DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. 5'-8" PT TABLE MODEL:FSDE-300 El DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. 5-8" TABLE MODEL:FSDE-300 7-1 DUCT CLEAN OUT ON EACH BRANCH DUCT MAX. 12 FT. 5'-8" ---- TABLE MODEL:FSDE-300 S. `Tr? -&J BB FLOOR 0'- ELEVATION - D SCALE: 3/8" = 1-0" - MIN. 1/4" PITCH PER FLOOR MIN. 16 GA. GALV. DUCT 34-11" MIN. 1/4" PITCH PER FLOOR MIN. 16 GA. GALV. DUCT SEE DETAIL 6 PAGE A3 5. HOOD EXHAUST ENCLOSURE EXTERIOR FINISH GWB AND PAINT 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WVVVV.CATCHSTUDIO.COM ARCHITECT: 6192 REGISTERED ARCHITECT THAN SUTAN STATE OF WASHINGTON PROJECT TITLE: SUMI KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: ELEVATIONS REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: . '44Y JAN 08 2020 PERMIT CENTER DATE: 01/02/20 SHEET# A5 BBQ VENT TABLE SPECIFICATIONS Intertek Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 3196485SAT-002 Original Issued: 8-Dec-2009 Revised: None Standard for Exhaust Hoods for Commercial Cooking Equipment UL 710, 5th Edition, Issued 12/28/95 Standard(s) Applicant Address Country Contact Phone FAX Email Joseph Chung Enterprises 11837 Front St. Norwalk CA 90650 USA Joseph Chung 626-833-5353 562-864-1339 bbq@jcdkbs.com Report No. 3196485SAT-002 Page 2 of 29 Joseph Chung Enterprises 2.0 Product Description Product Brand name Description Models Model Similarity Ratings Other Ratings Manufacturer Address Country Contact Phone FAX Email Joseph Chung Enterprises 11837 Front St. Norwalk CA 90650 USA Joseph Chung 626-833-5353 562-864-1339 bbq@jcdkbs.com Issued: 08-Dec-2009 Revised: None Dynamic Korean Barbecue System (DKBS-RDD) NA The product covered by this report is a permanently installed Korean BBQ System. The unit consists of a grill assembly, burner control, and filter box and exhaust blower, installed in a cabinet. DKBS-RDD 115V, 0.8 A, 60/50 Hz Airflow: 134 CFM @ 0.00" W.C. static pressure, 126 CFM @ 0.01" W.C. static pressure Report No. 3196485SAT-002 Joseph Chung Enterprises 3.0 Product Photographs Photo 3 - Burner Control Page 4 of 29 Photo 4 - Gas Control Valve manufactured by Sangium Micron (V-037C) Issued: 08-Dec-2009 Revised: None Report No. 3196485SAT-002 Joseph Chung Enterprises 3.0 Product Photographs Page 6 of 29 Photo 7 - Galvanized Grease Baffle Filter (11.5-in x 11.5-in x 2-in) Photo 8 - Grease Filter Box with Grease Catch Issued: 08-Dec-2009 Revised: None Report No. 3196485SAT-002 Joseph Chung Enterprises 3.0 Product Photographs Page 3 of 29 Photo 1 - Dynamic Korean Barbecue System (DKBS-RDD) Photo 2 - Grill Surrounded by the Vented Top Cover Issued: 08-Dec-2009 Revised: None Report No. 3196485SAT-002 Joseph Chung Enterprises 4.0 Critical Components oItem Name no.1 2 1 Grill Various Manufacturer/ trademark2 2 2 Vented Top Cover Various 5 3 Ignition Module Inter Tech Co. 7 4 Grease baffle filter 8 5 Grease Catch Various 9 6 Exhaust Blower Dayton Smith Filters Corporation Page 8 of 29 Issued: 08-Dec-2009 Revised: None Type / model2 Technical data and securement means Various Various ICT Sparker, ISD 15-002 Cast iron, 12.9" diam, 1" high NR 304 stainless steel, 16" diam. Perforated w/ 67 holes Mark(s) of conformity3 DC 1.5, 130mA MAX, AA battery NR Fire Patrol "G" Galvanized steel, 11-112" x 11-1/2" UL Various 304 stainless steel NR 2C647 1500 RPM, 115V, 0.74A, inlet CE, CSA diam. 4-1/2". NOTES: 1) Not all item numbers are indicated (called out) in the photos, as their location is obvious. 2) "Various" means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used. 3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only visual examination is necessary "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details. Report No. 3196485SAT-002 Page 7 of 29 Issued: 08-Dec-2009 Joseph Chung Enterprises Revised: None 3.0 Product Photographs Photo 9 - Exhaust Blower i 15V 60r JI $Z • .4--ROTATION,,,,, Ott' THERMAI EY PFkOTEcrED pltOTEG I00 TF RMICAMEN.t,E pROTIF6F TNERMIOUEMeNT M Ugr of GROUNDED, TA sr DEBF (ONFCTAR A TIER wriOrpR DOI r E THE MIS A LA TERRC‘ pour: paYton r l ef M ry cc, N,ies. 0. JC CORPORATION DYNAMIC KOREAN BARBECUE SYSTEM B MODEL DKBS-RDD Illustration 1 - Dynamic Korean Barbecue System (DKBS-RDD) DISH WASHER SPECIFICATIONS Single Rack • In Line • Low Energy Dishmachine • Auto-Chlor System's proprietary WaterSaverN design uses as little as 1.09 gallons/rack • Powerful 1 HP pump delivers high pressure spray and mechanical cleaning action for single pass cleaning performance • Built in water pressure regulator provides consistent water usage and cleaning results • Exclusive fill -through -the -pump feature flushes and cleans the wash pump and spray system with every cycle • External sump and screen provide easy access for cleaning • Regularly scheduled 28-day service ensures sparkling results, minimizes mechanical problems and reduces operating costs • Benefiting from more than 75 years of improvements and dishwashing experience and knowledge Energy Efficient • Exceeds Energy Star requirements • Low temperature chemical sanitizing saves energy Total Service. Total Satisfaction" SYSTEM w tochlormn 'k e). ACM30002 Single Rack • In Line • Low Energy Dishmachine Specifications Standard 90 second cycle, 38 radk/hr A - Electrical -115 VAC, 60Hz, 1 PH - 20A Dedicated Circuit Recommended - Connects to Grounded Wall Outlet or 34" Condult dependng on local building codes 8 - Weer Consumption 1.09 gaUrac k (41.3 GPH) - Water Supply Flow Rate 7.5 GPM Minimum - Water Supply Tamp 120"F Minimum - Water Supply Connectlon 34" NPT female - Baddlow protection provided by ASSE 1001 Vacuum Breaker C - Drain Connection 2" MPT - 20" above floor C• - Optional Scrap Accumulator - Connection 2" MPT - Centerline 1534" above floor D - Wash Cavity Clearance 17" Max Height E - Rack Clearance - 20 54" between tracks - Rack Se20"x20" F - Table Height at Machine Entrance 34" Available Options: - Auto -Start - Leg Extensions : 3" - Vapor Removal System (VRX) - 72 second cycle, 47 Rackalhr, 51 GPH - B0 second cycle, 55 Radcalhr, B0 GPH -Tall Hood 27" Max. Height Wash Cavity Optional Supplemental Water Heaters Available An % od Integrated wider hosing s a m h aysaable for trim moclehrrechine. The interested .yelem mounts wttt n the kuneserk dale machine so no sddrbnd Ilea space Is required. The Integrated heater Is Ideal fa facades coil Insufficient War hoodoo caps*, on -demand Myie water heaters, or remotely looted heelers. The heater ran operate on 6M 2011-240V drib ulna saber single cause phew power. Conlart yorr loran Arso-CNa &Mom mpresentMlre for mare Infonnetlon Note: This unit does not produce heat or steam Total Service.Total Satisfaction. DESIGN STUD I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322,4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM ARCHITECT: 6192 REGISTERED ARCHITECT THAN SUTAN STATE OF WASHINGTON PROJECT TITLE: SUMI KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: BBQ VENT TABLE AND DISH WASHER SPECIFICATIONS REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: PERr:!lT CENTER DATE: 01/02/20 SHEET# A6 ED 16 3 1513/12/081 Informative SYSTEM .utochlor.com CC CC CC Lij C34' CM CC ILI LLI CI La 5 2 0 cc 38= +22 +18 OUTLET PLAN SCALE :1/4" = 11-0" +18 +18 LED STRIP LIGHT ALL PERIMETER 29'-7" LF. GFCI +48 0+42 €3= LED STRIP LIGHT ALL PERIMETER 18'-8" LF. GFCI +28 -er' GFCI +40-e" +1118 +18 GFCI +28 PROJECT INFO: ELECTRICAL / PHONE / DATA NOTES: COORDINATE PHONE/DATA INSTALLATION WITH APPROPRIATE SUB -CONTRACTOR., TENANT, & BUILDING MANAGER PRIOR TO CONSTRUCTION. ALL EXISTING ELECTRICAL DEVICES ARE TO REMAIN, UNLESS NOTED OTHERWISE. ALL OUTLETS TO BE INSTALLED AT LOCATIONS SHOWN BY DIMENSIONS ON THE POWER & SIGNAL PLAN. DIMENSION ALL OUTLETS FROM THE CENTERLINE OF THE OUTLET BOX. NON -DIMENSIONED OUTLETS ARE TO LOCATED AT THE NEAREST WALL STUD. CENTER ALL NEW WALL MOUNTED OUTLETS/RECEPTACLES AT +18" A.F.F., U.O.N. WHEN OUTLETS ARE GROUPED TOGETHER (2 OR MORE), SPACE NO MORE THAN 2" APART. ALL WALL COVER PLATES SHALL BE WHITE, UNLESS B/S IS DIFFERENT, MATCH B/S OR VERIFY W/ BUILDING MANAGER. POWER/SIGNAL AND REFLECTED CEILING PLANS ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED AND CHANGES MADE BASED ON THE EXISTING CONDITIONS ABOVE THE CEILING OR IN THE WALLS. NOTIFY ARCHITECT FOR ANY SIGNIFICANT CHANGE, TENANT TO PROVIDE AND INSTALL THE TELEPHONE AND DATA CABLING. CONTRACTOR TO COORDINATE SCHEDULING AND OTHER REQ, WITH TENANT. ALL TELEPHONE AND COMPUTER WIRES SHALL BE PULLED BY TENANT CONTRACTOR U.O.N. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL WIRES AND BOXES AT EACH LOCATION. ALL/ANY CORE DRILL LOCATIONS SHALL BE VERIFIED BY BLD. APPROVED ULTRASOUND OR X-RAY VIEWING PRIOR TO DRILLING. ALL UNUSED CORE DRILLS SHALL BE PLUGGED AND CAPPED AS REQUIRED TO MAINTAIN FLOOR FIRE RATING. CONTRACTOR SHALL OBTAIN APPROVAL FROM BUILDING MGR. FOR ALL THERMOSTAT LOCATIONS. ELECTRICAL/PHONE/DATA LEGEND (NEW SHOWN ONLYPOORDINATE PHONE/DATA INSTALLATION -(1--' WALL MOUNTED DUPLEX RECEPTICAL OUTLET f,T-,)- i FLOOR MOUNTED DUPLEX RECEPTICAL OUTLET 41 WALL MOUNTED COMBINATION TELEPHONE AND DATA OUTLET -.ye} WALL MOUNTED DUPLEX RECEPTACLE OUTLET - DEDICATED 120V, 20A WALL MOUNTED 220 V RECEPTICAL OUTLET +60 HEIGHT ABOVE THE FINISHED FLOOR (VERIFY W/ PROJECT MANAGER) N NEW GFI GROUND FAULT INTERRUPTER ELECTRICAL/PHONE/DATA PLAN PROVIDED BY THE DESIGNER. THIS DESIGN SHOWS NEW PROPOSED LOCATIONS DESIGNED FOR INFORMATION AND POTENTIAL BIDDING ONLY. ALL FINAL LOCATIONS TO BE APPROVED BY TENANT, THE BUILDING PROJECT MANAGER AND THE DESIGNATED CONTRACTOR PRIOR TO INSTALLATION. THE ARCHITECT IS NOT RESPONSIBLE FOR THIS DESIGN OR THIS SEPARATE PERMIT. CONTRACTOR TO DETERMINE, IF OUTLET LOCATIONS CAN BE REUSED AND TO REMOVE ANY OUTLETS NOT USED WITH APPROVAL OF THE BUILDING OWNER OR PROJECT MANAGER. KEY NOTES: ELECTRICAL / DATA / PHONE 1 ALL WALL MOUNTED ELECTRICAL FOR CHAIRS IS GFI PER MGF. RED .AND SET ABOVE PLUMBING CHASE COVER FOR ACCESS. 2 VERIFY ALL MGF REQ. FOR ALL EQUIPMENT USED IN THIS LAYOUT. TEC EP/Fin CITY OF DESIGN STUDIO 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206,322.4323 FAX. 206,322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WVVW.CATCHSTUDIO.COM ARCHITECT: 1 1 PROJECT TITLE: THAN SUTAN STATE OF WASHINGTON SUMI KOREAN GRILL 17250 Southcenter Pkwy SUITE #148 Tukwila, WA 98188 SHEET TITLE: OUTLET PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 01/02/20 JAN 09 2020 SHEET# PERMIT CENTER SEPARATE ERRILT A AP P 1 RPQ El