HomeMy WebLinkAboutPermit D19-0390 - SABEY CORPORATION - AUTOMATIC SLIDING DOOR ON 2ND FLOORNEW DOOR - COMMON
AREA
2811 S 102ND ST
EXPIRED
7/13/2021
D19-0390
Parcel No:
Address:
�~^� °~�7� &�°"^U
..U~� ��n Tukwila
Department mfCommunity Development
63OO5outhcenterBoulevard, Suite #1DO
Tukwila, Washington 9Q288
Phone:ZO6'431-367U
Inspection Request Line: 206-438'9350
Web site: http://www.TukwilaWA.Pov
DEVELOPMENT PERMIT
0423049190 Permit Number: D19-0390
Project Name: NEW DOOR - COMMON AREA
Issue Date: 1/15/2020
Permit Expires On: 7/13/2020
Owner:
Contact Person:
Name:
Contractor:
License No:
Lender:
Name:
Address:
SABEY CORPORATION
12201TUKVV|L4|mTERN'iBLVDFO,
TOM SPADER
lZZOITUKVV|L4INTERNATIONAL
8LVD4THFLOOR, TUKVViUA,WA,
98l69'5l2l
SABEY CONSTRUCTION INC
12I81TUKN/|L4|NTL8LVD4TH
FLOOR, TUKVV|U\WA, 98l68'5l2l
OWNER FUNDED
Phone: (205) 277'5271
Phone: (206)281-4200
Expiration Date: 1/12/2021
DESCRIPTION OF WORK:
INSTALL NEW AUTOMATIC SLIDING DOOR ON SECOND FLOOR FOR SECURITY PURPOSES.
Project Valuation: $10\00000
Type ofFire Protection: Sprinklers: YES
Fire Alarm: YES
Type ofConstruction: VB
Electrical Service Provided by: TUKWILA
Fees Collected: $537.06
Occupancy per IBC: 8
Water District: TUKYV|U\
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
international Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code.
National Electrical Code:
VVACities Electrical Code:
VVACl96'46B:
VVAState Energy Code:
2017
2017
2017
2015
Public Works Activities:
[hanne|izadon/Sthping:
[urb[ut/Acces$SidewaN:
Fire Loop Hydrant:
Flood Control Zone:
HauUnX/OveoiueLoad:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: O
Number: U
No
Permit Center Authorized Signature:
|
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. | am authorized to sign and obtain this
development permit and agree tothe conditions attached tothis permit.
Signature:Date:Print Name:
--� ;
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
4: The door installation to comply with International Building Code Sections 1010.1.4.2, 1010.1.43 and
2: All new fire alarm systems ormodifications toexisting systems shall have the written approval ufThe
Tukwila Fire Prevention Bureau. Nowork shall commence until afire department permit has been
obtained. (City Ordinance #2437)(|F[9VlJ)
1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests, (CityOrdinance5
#Z43hand #Z437)
]: Any overlooked hazardous condition and/or violation of the adopted Fire orBuilding Codes does not imply
approval ofsuch condition orviolation.
5: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
6: All permits, inspection record card and approved construction documents shall be kept at the site ofwork
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
7: VALIDITY OFPERMIT: The issuance orgranting ofupermit shall not beconstrued tobeapermit for, uran
approval of, any violation ofany of the provisions ofthe building code orofany other ordinances o{the City
of Tukwila. Permits presuming togive authority toviolate orcancel the provisions of the code or other
ordinances ofthe City ofTukwila shall not bevalid, The issuance ofapermit based onconstruction
documents and other data shall not prevent the Building official from requiring the correction of errors in
the construction documents and other data.
0
8: 'BUILDING PERM|T[OND|T|ON5***
Door shall meet egress and emergency egress requirements.
9: Doors shall swing indirection ofegress travel where serving anoccupant load ofSUurmore persons ora
Group Hoccupancy. (|F[lDl0IZ.1)
10: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge
or effort. (|F[l0I0l9)
Il: Exit hardware and marking shall meet the requirements ofthe international Fire Code. (|F[Chapter 10)
12: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of
e-resst/avei Access toexits shall bemarked byreadily visible exit signs incases where the exit orthepath
ofegress travel isnot immediately visible tuthe occupants. Exit sign placement shall besuch that nopoint
in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign,
whichever isless, from the nearest visible exit sign, (|F[1Ol3.1)
13: The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed
5pounds (ZZN). These forces do not apply to the force required to retract latch bolts or disengage other
devices that hold the door inaclosed position. For other swinging doors, aswell assliding and folding
doors, the door latch shall release when subjected toaIS-pound (G7N)force. The door shall beset in
motion when subjected toa3O'pound(l33N)force. The door shall swing toafull-open position when
subjected tual5'pound(67N)force. (|F[l01013) Swinging fire doors shall close from the full -open
position and latch automatically. The door closer shall exert enough force toclose and latch the door from
any partially open position. (IFC 703.2.3)
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (JQ6)438'935U
1700 BU|LD|NGF|NAL~*
1400 FIRE FINAL
CITY OF TUK0A
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Peet No. 121c1_ 030
Project No.
Date Application Accepted: / g"" /0 0
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address:
Tenant Name: NEW DOOR
PROPERTY OWNER
Name: International Gateway East LLC
Address: 12201 Tukwila Int'l Blvd
City: Tukwila State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Tom Spader
Address: 12201 Tukwila Int'1 Blvd
City: Tukwila State: WA Zip: 98168
Phone: (206) 281-8700 Fax: (206) 282-9951
Email: toms@sabey.com
GENERAL CONTRACTOR INFORMATION
Company Name: Sabey Construction
Address: 12201 Tukwila Int'1 Blvd
City: Tukwila State: WA Zip: 98168
Phone: (206) 281-8700 Fax: (206) 282-9951
Contr Reg No.: SABEYCI033KM Exp Date: 01/12/2021
Tukwila Business License No.: BUS-0102122
King Co Assessor's Tax No.: 042304-9190-06
2811 S. 102ND STREET, SEATTLE, WA 98168 Suite Number: Floor: 2
New Tenant: ❑ Yes ®..No
ARCHITECT OF RECORD
Company Name: Sabey Architecure
Architect Name: Kara Anderson
Address: 12201 Tukwila Int'l Blvd
City: Tukwila State: WA
Zip: 98168
Phone: (206) 281-8700 Fax: (206)
282-9951
Email: karaa@sabey.com
ENGINEER OF RECORD
Company Name: N/A
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: Sabey Corporation
Address: 12201 Tukwila Int'l Blvd
City: Tukwila State: WA Zip: 98168
Fl:\Applications \Forms -Applications On Line \2011 Applications\Pe
Revised: August 2011
bh
Application Revised - 8-9-11.docx
Page 1 of 4
BUILDING PERMIT INFORMATI1. 206-431-3670
Valuation of Project (contractor's bid price): $ 10,000
Describe the scope of work (please provide detailed information):
INSTALL NEW AUTOMATIC SLIDING DOOR ON SECOND FLOOR FOR SECURITY PURPOSES.
Will there be new rack storage? fl Yes
Existing Building Valuation: $
No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
87,500
VB
B
2"4 Floor
87,500
16
VB
B
3' Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
IZ Sprinklers J Automatic Fire Alarm 0 None D Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes J No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
HAApplicationsTorms-Applications On Line \ 2011 ApplicationsWermit Application Revised - 8-9-11.docx
Revised: August 201
hh
Page 2 of 4
PUBLIC WORKS PERMIT INF(IATION — 206-433-0179
Scope of Work (please provide detailed information):
N/A
Ca11 before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑ ...Water District # 125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certificate
0 .. Highline ❑ .. Renton
❑...Valley View 0 .. Renton
❑ ... Sewer Availability Provided
❑ .. Seattle
Septic System:
O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
0 ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way 0
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
0 ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Geotechnical Report
❑ .. Maintenance Agreement(s)
❑...Traffic Impact Analysis
❑ ... Hold Harmless — (SAO)
❑ ... Hold Harmless — (ROW)
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Abandon Septic Tank
❑ .. Curb Cut
0 .. Pavement Cut
❑ .. Looped Fire Line
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ...Permanent Water Meter Size... WO #
❑ ...Temporary Water Meter Size .. WO #
❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size
❑ ...Sewer Main Extension Public ❑ Private ❑
❑ ...Water Main Extension Public ❑ Private ❑
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
O ...Water ❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
State Zip
Day Telephone:
City
State Zip
H:\Applleations\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.doex
Revised: August 201 1
bh
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
AUTHO
A BUILDING OWNER OR HO ZED AGENT:
Signature: A "7/'• 71
Date: 12/10/2019
Print Name: TOM SPADER Day Telephone: (206) 277-5271
Mailing Address: 12201 Tukwila Intl Blvd Tukwila WA 98168
City State Zip
11: \ ApplicationsTonns-Applications On Line \ 2011 Applications\Permit Application Revised - 8-9-11.doex
Revised: August 2011
Page 4 of 4
Cash Register Receipt
city of Tukwila
Receipt Number
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$341.56
D19-0390 Address: 2811 S 102ND ST Apn: 0423049190
$341.56
Credit Card Fee
$9.95
Credit Card Fee
R000.369.908.00.00
0.00
$9.95
DEVELOPMENT
$317.01
PERMIT FEE
R000.322.100.00.00
0.00
$292.01
WASHINGTON STATE SURCHARGE
B640.237.114
0,00
$25,00
TECHNOLOGY FEE
$14,60
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R19719
R000.322.900.04.00
0.00
$14.60
$341.56
Date Paid: Wednesday, January 15, 2020
Paid By: BEN WALKER
Pay Method: CREDIT CARD 063728
Printed: Wednesday, January 15, 2020 9:43 AM 1 of 1
4414,4..
YSTE
0
CO
CITY OF TUKWILu
0017]40000802]74464500
Date: 01/15/2020 09:43:06 AM
CREDIT CARD SALE
MASTERCARD
CARD NUMBER: TKAN AMOUNT: $341.56
APPROVAL [p: 863728
RECORD #: 008
cLmx ID: Bill
X
(CARDHOLDER'S SIGNATURE)
I AGREE TO PAY THE ABOVE TOTAL AMOUNT
ACCORDING TO THE [4RO ISSUER AGREEMENT
(MERCHANT AGREEMENT IF CREDIT VOUCHER)
Thank you!
Merchant Copy
Cash Register Receipt - Receipt Number
City of Tukwila
DESCRIPTIONS
PermitTRAK
' ACCOUNT
QUANTITY
PAID
$195.50
D19-0390 Address: 2811 S 102ND ST
Apn: 0423049190
$195.50
Credit Card Fee
$5.69
Credit Card Fee
R000.369.908.00.00
0.00
$5.69
DEVELOPMENT
$189.81
PLAN CHECK FEE
. J
TOTAL FEES PAID BY RECEIPT: R19257
R000.345.830.00.00
0.00
$189.81
$195.50 '
Date Paid: Tuesday, December 10, 2019
Paid By: KARA ANDERSON
Pay Method: CREDIT CARD 062738
Printed: Tuesday, December 10, 2019 3:46 PM 1 of 1
SYSTEMS
0
CO
CITY OF TUKWILA
0017340000882374464500
Date: 12/I0/30I9 83:45:24 PM
CREDIT CARD SALE
MASTERCARD
x
{CARDHOLDER'S SIGNATURE}
I AGREE TO PAY THE ABOVE TOTAL AMOUNT
ACCORDING TO THE CARD ISSUER AGREEMENT
(MERCHANT AGREEMENT IF CREDIT VOUCHER)
Thank you!
Merchant Copy
Permit Number: D19-0390
Applied: 12/10/2019 Approved: 1/13/2020
Issued: 1/15/2020 Finaled:
Status: EXPIRED
Parent Permit:
Parent Project:
Details:
Description: NEW DOOR - COMMON AREA
Site Address: 2811 S 102ND ST
City, State Zip Code:TUKWILA, WA 98168
Applicant: NEW DOOR - COMMON AREA
Owner: SABEY CORPORATION
Contractor: SABEY CONSTRUCTION INC
INSTALL NEW AUTOMATIC SLIDING DOOR ON SECOND FLOOR FOR SECURITY PURPOSES.
SCHEDULED DATE
COMPLETED DATE
TYPE
INSPECTOR
RESULT
REMARKS
BUILDING FINAL**
Bill Centen
Notes:
3/16/2020 8:00
AM
3/9/2020
FIRE FINAL
AARON JOHNSON
APPROVED
Notes:
Fire final approved
Security door functional and allows egress via breakaway feature which was demonstrated at time of inspection to be functional.
appropriately displayed signage in place.
Printed: Wednesday, 29 September, 2021 1 of 1
'4
SUPERION
City of Tukwila
Department of Community Development
6/3/2021
TOM SPADER
12201 TUKWILA INTERNATIONAL BLVD 4TH FLOOR
TUKWILA, WA 98168-5121
RE: Permit No. D19-0390
NEW DOOR - COMMON AREA
2811 S 102ND ST
Dear Permit Holder:
Allan Ekberg, Mayor
Nora Gierloff, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 7/13/2021.
Based on the above, you are hereby advised to:
1) Login to the City of Tukwila's Online Portal https://tulcw-egov.aspgov.com/BP/index.html to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address
your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 7/13/2021, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Shana Markstrom
Permit Technician
File No: D19-0390
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
Building Division
c?c Wts
° PENT COORD COP
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D19-0390
DATE: 12/11/2019
PROJECT NAME: NEW DOOR - COMMON AREA
SITE ADDRESS: 2811 S 102ND ST
X Original Plan Submittal Revision #
Response to Correction Letter #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
FA MU iftSA
Fire Prevention
Structural
6 Mr
Planning Division II
Permit Coordinator
•
PRELIMINARY REVIEW:
Not Applicable Ei
(no approval/review required)
DATE: 12/12/19
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 1/9 2020
Approved
Corrections Required
Approved with Conditions r
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
111
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire Ping 0 PW Staff Initials:
12/18/2013
°Labor & industries (https://lni.wa.dov)
Contractors
SABEY CONSTRUCTION INC
Owner or tradesperson
Principals
SABEY, DAVID ARTHUR, PRESIDENT
SEWELL, PATRICIA ANNE, SECRETARY
POOLE, LAURENT D, SECRETARY
(End: 01/19/2011)
HARMON, JAMES N, TREASURER
(End: 01/19/2011)
Doing business as
SABEY CONSTRUCTION INC
WA UBI No
601 532 164
12201 TUKWILA INT'L BLVD
4TH FLOOR
SEATTLE, WA 98168-5121
206-281-4200
KING County
Business type
Corporation
Governing persons
SABEY
CORPORATION
DAVID A SABEY;
JOHN D SABEY;
PATRICIA SEWELL;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active
Meets current requirements.
License specialties
GENERAL
License no.
SABEYCI033KM
Effective — expiration
05/14/1997— 01/12/2021
Bond
HARTFORD FIRE INSURANCE CO
Bond account no.
52BSBCQ3983
$12,000.00
Received by Lad Effective date
12/20/2004 12/31/2004
Expiration date
Until Canceled
Insurance
National Fire Ins of Hartford $1,000,000.00
Policy no.
2094061165
Received by L&I Effective date
10/20/2019 11/01/2016
Expiration date
04/30/2021
Insurance history
Savings
(in lieu of bond)
$6,000.00
10
REFERENCE SYMBOLS
ABBREVIATIONS
PROJECT DIRECTORY
DRAWING INDEX
ADDITIONAL ABBREVIATIONS ARE DEFINED IN LEGENDS THROUGHOUT THE DRAWING SET.
A-001 COVER SHEET AND PROJECT INFORMATION
AC
ASPHALTIC CONCRETE
ID
INSIDE DIAMETER
ARCHITECT/DESIGNER: PLUMBING ENGINEER:
ACC
ACCESSIBLE
INCL
INCLUDE, INCLUDING
SABEY ARCHITECTURE TBD-Design Build by G.C.
A-003 SITE PLAN
A.XXX A.XXX
A.XXX
ACP
ACOUSTICAL CEILING PANEL
INFO
INFORMATION
12201 TUKWILA INPL BLVD, FOURTH FLOOR
A-101 FLOOR CONSTRUCTION PLAN
ACST
ACOUSTICAL
INSUL
INSULATE, INSULATION
SEATTLE, WA 98168
AD
AREA DRAIN
INT
INTERIOR
TEL: (206)281.8700
BUILDING SECTION INDICATOR
WALL SECTION INDICATOR
ADDM
A
ADDENDUM
ADJUSTABLE
IWD
INDIRECT WASTE DRAIN
FAX: (206)282.9951 MECHANICAL ENGINEER:
ATTN: TOM SPADER TBD-Design Build by G.C.
AFF
ABOVE FINISHED FLOOR
JAN
JANITOR
EMAIL: TOMS@SABEY.COM
XX
AHU
AIR HANDLING UNIT
JT
JOINT
A-X
ALT
ALTERNATE
BUILDING OWNER:
(
ALUM
ANOD
ALUMINUM
ANODIZED
KIT
KITCHEN
RIVERFRONT TECHNICAL PARK, LLC TBDELECTRICAL-DBuild b G.C.
TBD -Design Build by G.C.
(
APPROX
APPROXIMATE
L
LONG
12201 TUKWILA INPL BLVD, FOURTH FLOOR
�� i
APT
APARTMENT
LAM
LAMINATE, LAMINATED
SEATTLE, WA 98168
ENLARGED DETAIL INDICATOR
SECTION DETAIL INDICATOR
ARCH
AUTO
ARCHITECT, ARCHITECTURAL
AUTOMATIC
LAU
LAV
LAUNDRY
LAVATORY
TEL: (206)281.8700
FAX:(206)282-9951 FIRE I LIFE SAFETY ENGINEER:
XX
XX XX
AV
AWP
AUDIO VISUAL
ACOUSTICAL WALLPANEL(S)
LT
LTG
LIGHT
LIGHTING
ATTN: DEBBIE SABEY n 8d1d by
EMAIL:DEBBIES@SABEY.COM TBD - Deli 9G.C.
fA-XXX
BB
BULLETIN BOARD
MAS
MASONRY
A-XXX
XX A-XXX XX
BD
BOARD
MATL
MATERIAL
GENERAL CONTRACTOR:
BLDG
BUILDING
MAX
MAXIMUM
SABEY CONSTRUCTION
XX
BLKG
BLOCKING
MECH
MECHANICAL
12201 TUKWILA INTL BLVD, FOURTH FLOOR PLUMBING, MECHANICAL, ELECTRICAL,
EXTERIOR ELEVATION INDICATOR
INTERIOR ELEVATION INDICATOR
BO
BOT
BRG
BOTTOM OF
BOTTOM
BEARING
MED
MEMB
MF77
MEDIUM
MEMBRANE
MEZZANINE
SEATTLE, WA 98168 LIFE SAFETY PERMITS UNDER SEPERATE
TEL: (206) 281-8700 SUBMITTALS.
FAX: (206) 282-9951
BRZ
BRONZE
MGT
MANAGEMENT
ATTN: PAUL SWANSON
- _MATCNLINE
QX
BSMT
BASEMENT
MR.
MAXIMUM FORESEEABLE LOSS
EMAIL: PAULS@SABEY.COM
SEE XX1A-XXX
CD
BUR
BUILT UP ROOFING
MFR
MANUFACTURE, MANUFACTURE
MH
MANHOLE
MATCH LINE INDICATOR
DRAWING REVISION INDICATOR
CAB
CB
CEM
CABINET
CATCH BASIN
CEMENT, CEMENTITIOUS
MIN
MISC
MO
MINIMUM, MINUTE
MISCELLANEOUS
MASONRY OPENING
X.X - X.X
X.X - X.X
CGR
CEIC
CORNER GUARD
NIS
MTD
MOP SINK
MOUNTED
BUILDING ADDRESS
VICINITY
T1Y MAP
CH
COAT HOOK
MTL
METAL
'P
CI
CASTIRON
MVBL
MOVABLE
_
CJ CONTROL JOINT N NORTH
CICP
CAST
CENTERLINEERLINE
NIC
NOT IN CONTRACT
RIVERFRONT TECHNICAL PARK
EXISTING COLUMN GRIDLINE INDICATOR
NEW COLUMN GRIDLINE INDICATOR
CLG
CLO
CLR
CEILING
CLOSET
CLEAR
NO
NOM
NTS
NUMBER
NOMINAL
NOT TO SCALE
2811S.102NDSTREET
SEATTLE, WA 98168
•ate^ -"
ELXXX.XX EL.XXX-XX"
CMU
CONCRETE MASONRY UNIT
OC
ON CENTER
CO
COL
CLEAN OUT, CASED OPENING
COLUMN
OH
OD
OVERHEAD
OUTSIDE DIAMETER
COMM
COMMUNICATION
OPNG
OPENING;.
CONIC
CONCRETE
OPP
OPPOSITE
CONN
CONNECTION, CONNECT
4
DATUM INDICATOR OR WORK POINT
SPOT ELEVATION INDICATOR
CONSTR
CONT
CONSTRUCTION
CONTINUOUS, CONTINUE
ORD
OTS
OVERFLOW ROOF DRAIN
OPEN TO STRUCTURE ABOVE
3,=„ •. s.
_
E XXXXX EQUIPMENT INDICATOR
CORRIDOR
(t
ROOM NAME
X XXXXX FIXTURE INDICATOR
CPT
CSWK
CARPET
CASEWORK
PBD
PRCST
PARTICLEBOARD
PRECAST
SCOPE OF WORK
®
F XXXXX FURNITURE INDICATOR
CTR
CU
CENTER
CUBIC
PD
PLANTER DRAIN
G XXXXX GRAPHIC/SIGNAGE INDICATOR
D
DEEP, DEPTH
PERP
PLAN
PERPENDICULAR
PLASTIC LAMINATE
K ,,
MISCELLANEOUS INDICATORS
DEL
DOUBLE
PLAS
PLASTER
ADDING NEWAUTOMATIC SLIDING DOOR ON SECOND FLOOR FOR SECURITY PURPOSES.
Y'
,� =",m•,=�
ROOM INDICATOR
DEMO
DET
DEMOLISH, DEMOLITION
DETAIL
PLYWD
PNL
PLYWOOD
PANEL
e
,....„e, a
- „�,.,...
OF
DRINKING FOUNTAIN
PL
PROPERTY LINE
�'�
CD
F XXXXXX
DIA
DIAMETER
PR
PAIR
DIAG
DIAGONAL, DIAGRAM
PRKG
PARKING
DM
DIMENSION
PROP
PROPERTY
'
(DOOR) OPENING INDICATOR
FINISH INDICATOR
DIV
DMPF
DN
DIVIDE, DIVISION
DAMPPROOF, DAMPPROOFING
DOWN
PT
PTN
PAINT, POINT, PRESSURE TREATED
PARTITION
4 p
O
OR
DOOR, DRESSING ROOM
R
RCP
RADIUS, RISER
REFLECTED CEILING PLAN
DS
DW
DOWNSPOUT
DISHWASHER
RD
DR
ROOF DRAIN, ROAD
N, ROAD
4 ,•-
WINDOW INDICATOR
CEILING HEIGHT INDICATOR
DWG
DWR
DRAWING
DRAWER
r
REF
REF
REINF
ROOF
,
REFRIGERATOR
REINFORCED, REINFORCING
a =-
_.
MATERIAL PER FINISH LEGEND
( )
FINISH PER FINISH LEGEND)
(
E
EIFS
EAST
INSULATION AND
EXTERIOR SYSTEM
FINISH SYSTEM
READ
REV
RFG
REQUIRED
REVISED, REVISION
ROOFING
MAT F-XXX
EJ
EXPANSION JOINT
RM
ROOM
pt XX
EL
ELEVATION
XX'-XX" AFF
ELEC
ELECTRIC, ELECTRICAL
RTO
RGHTHOPENING
CODE AND BUILDING INFORMATION
HEIGHT
ELEV
ELEVATOR
WALL TYPE INDICATOR
CEILING HEIGHTIMATERIAUFINISH INDICATOR
ENCL
EP
EQ
ENCLOSE, ENCLOSURE
ELECTRIC PANEL
EQUAL
S
SCWD
SCHED
SD
SOUTH, SPANDREL
SOLID CORE WOOD
SCHEDULE
STORM DRAIN
PROJECT NAME: PROVIDENCE SUITE 210 EXPANSION
to -WITH
QFE
MOUNTEDTOWALL
BRACKET
EQUIP
ESCAL
EQUIPMENT
ESCALATOR
SECT
SG
SECTION
SAFETY GLASS
SITE ZONING: MIC/H
EXH
EX
EXHAUST
EXPANSION, EXPOSED
SGL
SINGLE
_� INWALL-MOUNTED
EXIST
EXISTING
SHT
SHEET
KING COUNTY ASSESSOR'SPARCEL NUMBERS: 042304-9190
KEYNOTE
CABINET
FIRE EXTINGUISHERS
FA
FIREALARM
SHTHG
SIM
SPEC
SHEATHING
SIMILAR
SPECIFICATION
APPLICABLE CODES:
FCIO
FURNISHED BY CONTRACTOR
INSTALLED BY OWNER
SPKLR
SPKR
SPRINKLER
SPEAKER
BUILDING CODE: 2015INTERNATIONAL BUILDING CODE (WAC51.50)
(PROPERTY) LEGAL DESCRIPTION
(NON -RATED PARTITION)
FD
FLOOR DRAIN
SQ
SQUARE
MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE AC51.52 )
EXISTING
FDC
FIRE DEPARTMENT
SS
SERVICE SINK
(SHOW
(SHOWN SHADED)
- (1-HOUR RATED PARTITION)
CONNECTION SST STAINLESS STEEL STC SOUND TRANSMISSION CLASS
PLUMBING CODE: 2015 UNIFORM PLUMBING CODE (WAC 51.56)
(2-HOUR RATED PARTITION)
FDTN
FOUNDATION
STD
STANDARD
LEGAL DESCRIPTION: PORTION OF SE 1/4 • BEGIN SW CORNER OF GOV LOT 11 IN SE 114 OF SECTION 04-23-04 TH S 89.22-06 E 988.27 FT TH N 1445.08 W 477.09 FT
-----------�I P
FE
FEC
FIRE EXTINGUISHER
FIRE EXTINGUISHER
STL
STEEL
ELECTRICAL CODE: 2015 INTERNATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS
TO INTERSECTION WITH N LINE OF S 460 FT OF GOV LOT 11 & NELY MARGIN OF PRIMARY STATE HIGHWAY
NO 1 TH IN 14-45-08 W 689.81 FT TO SWILY MARGIN OF 200
EXISTING TO BE DEMOLISHED L/
_ - - (3-HOUR RATED PARTITION)
CABINET
STOR
STORAGE
FOOT SEATTLE TRANSMISSION LINE TH IN 1445-08 W 22.70 FT TAP OF SPIRAL CURVATURE TH CONTINUING ALONG NELY MARGIN ALONG SPIRAL CURVE TO LEFT
FH
FIRE HYDRANT
STRUCT
STRUCTURAL
ENERGY CODE: 2015WASHINGTONSTATE ENERGY CODE (WAC51-11C)
THE CHORD BEARING N 15-07-51 W 152.94 FT TAP OF SIMPLE CURVATURE TH ALONG NE MARGIN NWLY 340.67 FT ALONG ARC OF NON TANGENT CURVE TO LEFT
(SHOWN DASHED)
- • • • • - • • • • - (4-HOUR RATED PARTITION)
FHC
FIRE HOSE CABINET
SUSP
SUSPENDED
RADIUS OF 3970 FT RADIUS POINT BEARING S 74-07.22 W THRU CIA OF 04-55-OD TH CONTINUING ALONG SAID NELY MARGIN N 11-24-57 E 327.11 FT TO POINT OF
FIG
FIGURE
T
TREAD, TEMPERED
FIRE CODE: 2015INTERNATIONAL FIRE CODE (WAC51.54A)
BEGINNING TH N 11-24-57 E 61.40 FT TAP OF SIMPLE CURVE TH CONTINUING ALONG SAID NELY MARGIN NWILY 191.94 FT ALONG ARC OF NON TANGENT CURVE TO
-i- SMOKE BARRIER
SMOKE PARTITION
FIN
FLEX
FINISH, FINISHED
FLEXIBLE
T&G
TEL
TONGUE AND GROOVE
TELEPHONETEMP TEMPERATURE, TEMPORARY
FUEL GAS CODE: 20151NTERNATIONAL FUEL GAS CODE
LEFT RADIUS OF 4190 FT RADIUS POINT BEARING S 64.42-23 W THRU CIA OF 02-07-29 TH N 27-01-05 E 89.78 FT TH N 48-11-59 E 442.51 FT TH S 41-52-02 E 881.11 FT TH
S 46-05-28 W 406.87 FT TH N 41-52-51 W 627.47 FT TH S 48.71-04 W 278.98 FT MIL TO POB - (PORTIONS OF LOTS i & 2 OF K C SHORT PLAT NO 588023 RECORDING NO
NEW
FUR
FLUOR
FLOOR, FLOORING
FLUORESCENT
TER
THK
TERRAZZO
THICK, THICKNESS
ACCESSIBILITY CODES: WASHINGTONSTATE ACCESSIBILITY CODE (WAC51-50)
9006050697•• LOT IOFCITY OFTUKWILA BOUNDARY LINE ADJUSTMENT NOL96-0002RECORDING
NO9707090733
FO
FACE OF, FINISHED OPENING
TYPE OF WORK
PARTITIONS
FDIC
FP
FURNISHED BY OWNER/
INSTALLED BY CONTRACTOR
FIRE FIREPROOF
TO
TSTAT
TV
TOP OF
THERMOSTAT
TELEVISION
USE GROUP AND OCCUPANCY:
NO CHANGE TO OCCUPANCY GROUP
RCP SYMBOLS
FIR
FRMG
RAME,FIRERAPROTECTION,
FRAME, FIRE RATED
FRAMING
TYP
TYPICAL
OCCUPANCY: B(OFFICE)
FRT
FIRE RETARDANT TREATED
REVIEWED FOR
FT
FTG
FUT
FOOT, FEET
FOOTING
FUTURE
U/C
UGND
UNFIN
UNDER COUNTER
UNDERGROUND
UNFINISHED
EXISTING TYPE OF CONSTRUCTION:
ICC CONSTRUCTION TYPE VB
CODE COMPLIANCE
APPROVED
CEILING -MOUNTED
El
HVAC DIFFUSERS
®® (SIZEANDTYPEPER
PVC
FABRIC
LON
UNLESS OTHERWISE NOTED
NUMBESABOVERIES:
20(2' FLUORESCENT LIGHT
CEILING -MOUNTED
MECHANICAL DRAWINGS)
®
FWC
FWP
ALL CO ERINGCABINET
FABRIC WALL COVERING
FABRIC WRAPPED PANEL(S)
VERT
VEST
VERTICAL
VESTIBULE
STORIES ABOVE GRADE PLANE: 2
STORIES BELOW GRADE PLANE: 0
0-
2'X4'FLUORESCENTLIGHT
GA
GAGE
VNR
VENEER
SEISMIC DESIGN CATEGORY:
GENERAL NOTES
CEILING•MOUNTED
GALV
VR
VAPOR RETARDER
D
City of Tukwila
TX4'FLUORESCENTLIGHT
GEN
GENEARAL, GENERATOR
VAC
VINYLWALLCOUERING
1. DO NOT SCALE THE DRAWINGS.
(HIDDEN)CEILING-MOUNTED
I--{
HVAC RETURNS/EXHAUSTS
SIZE AND TYPE PER
®® (
GFRC GLASS -FIBER try WEST, WIDE
REINFORCED CONCRETE try/ WITH
H
PROPOSED AREA OFREMODEL:
16SFOFPROJECTAREA
STRIP FLUORESCENT LIGHT
MECHANICAL DRAWINGS)
GFRG
GLASS -FIBER
REINFORCED GYPSUM
W/O
WITHOUT
(EXPOSED) CEILING -MOUNTED
GFRP
GLASS -FIBER
WC
WATER CLOSET, WALLCOVERING
CORE AND SHELL FIRE RATINGS:
2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK.
STRIP FLUORESCENT LIGHT
CEILING -MOUNTED HVAC ITEMS
REINFORCED PLASTIC
WD
WOOD
AS EXISTING - NO CHANGE
RECEIVED
WALL -MOUNTED
GL
GLASS
WH
WALL HYDRANT
3, THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE
CITY OF TUKWILA
F� STRIP FLUORESCENT LIGHT
GYP
GYPSUM
WP
WEATHERPROOF, WATERPROOF,
INTERIOR FINISHES:
SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE
®
GYP BD
GYPSUM BOARD
WR
WATERPROOFING, WORK POINT
WATER RESISTANT
PER 803.9 CLASS C FINISHES WITH EXCEPTION OF EXITS WHERE GLASS B IS USED
ALL PORTIONS OF THE W DESCRIBED IN THE CONTRACT DOCUMENTS NOTIFY
THE ARCHITECT FORRRESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.
DEC O g 2019-
0 DOWNLIGHT
H
HB
HIGH
HOSE BIBB
WT
WWF
WEIGHT
WELDED WIRE FABRIC
MEANS OF EGRESS:
SEE t/A-101, OVERALL FLOOR PLAN
4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS
PERMIT CENTER
O ACCENT DOWNLIGHT
CEILING -MOUNTED ACCESS PANEL
HCWD
HOLLOW CORE WOOD
XFMR
TRANSFORMER
OTHERWISE INDICATED.
WALL -WASHER DOWNLIGHT
HD
H
HOW
HOW
HAND DRYER
HARDBOARD HARDWARE
PARKING:
NO CHANGE TO PARKING IS PROPOSED IN CONJUNCTION WITH THE PROJECT, PARKING DEMANDS AS A
5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE
SCONCE -TYPE
X
HDWD
HARDWOOD
RESULT OF COMMERCIAL TI ARE MET BY EXISTING SITE PARKING FACILITIES. ALL ACCESSIBLE SITE FEATURES
LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS SIX INCHES FROM THE FACE
OF
b (WALL -MOUNTED) LIGHT
HM
HO
HOLLOW METAL
HOLD OPEN
AND PARKING STALLS ARE PROVIDED PER THE BUILDING LANDLORD.
THE NEARBY WALL UNLESS OTHERWISE INDICATED. ALL OTHER DOORS AND CASED
OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL INTERSECTIONS.
® CEILING -MOUNTED EXIT LIGHT
CEILING -MOUNTED FIRE SPRINKLER
RIZ
HR
HORIZONTAL
HOUR
6. ITEMS INDICATED AS BIDDER DESIGNED SHALL BE DESIGNED AND ENGINEERED BY THE
.ermY�
HT
HEIGHT
CONTRACTOR AND/OR SUBCONTRACTOR IN COMPLIANCE WITH APPLICABLE LEGAL
Dig
WALL -MOUNTED
HVAC
HEATING, VENTILATING,
REQUIREMENTS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BYAQUALIFIED
O
AND AIR CONDITIONING
PROFESSIONAL ENGINEER, USING PERFORMANCE AND DESIGN CRITERIA INDICATED.
STANDARD LIGHT FIXTURES
CEILING -MOUNTED SPEAKER
SABEY
SABEY ARCHITECTURE
12201 Tukwila Int' Blvd - 4th Floor
Seattle, WA 98168
206.281.8700
Sabey.com
k SEPARATE PERMIT
0 RE UIRED FOR:
Mechanical
Electrical
Plumbing
t Gas Piping
Cily of Tukwila
BUILDING DIVISION
6194 R GIST RED
I T
KARA M. ANDERSON
STATE OF WASHINGTON
SLIDING DOOR
ADDITION
RIVERFRONT TECHNICAL PARK
2811 S 102ND ST
TULW ILA, WA 98168
r,g,....- ..: 'o me scope
'xil - : val or the
L.ubmittaland
Bw6a!:',: • slon.
ons wdI rc..,.re a new Dian
,nC.ac- ' " oval plan revie
FILE
Pertntt No. � 1 6
Plan review approval is sunlec: to errors ano
omissions. Approval of construction documents does
notauthorize the violation of am 3-,)opted code Or
ordinance Receipt of apor vec -.e1a Copy and
ons -gea:
By.
Date:,
C,rY of i,+kw=:
MARK I DATE DESCRIPTION
PROGRESS DATE: 12/9/19
DRAWN BY: TS
CHECKED BY: TS
APPROVED BY: KA
PROJECT NO:
All drawings and written material appearing herein constitute
the odgloat and unpublished work of the Sabey Corporation
and the same may not be duplicated, used or disclosed
without the written consent of the Sabey Corporation.
e
2
3 4 5 6 7 8 9 10
F
E
D
C
B
A
Zo 11 0 I ULINU J 1 KCC I
AREA OF WORK ON
THE SECOND FLOOR
RIVERFRONT TECHNICAL PARK SITE PLAN
1" = 40'-0"
1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 13 2020
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 0 9 2019
PERMIT CENTER
SASEY
SABEY ARCHITECTURE
12201 Tukwila Int' Blvd • 4th Floor Seattle,
WA 98168
206,281, 3700
Sabey.com
6194 REGISTERED
AR I
KARA M. ANDERSON
S-WE OF WASHiNGTON
SLIDING DOOR
ADDITION
RIVERFRONT TECHNICAL PARK
2811 S 102ND ST
TULWILA, WA 98168
MARK I DATE DESCRIPTION
PROGRESS DATE: 12/9/19
DRAWN BY: TS
CHECKED BY: TS
APPROVED BY: KA
PROJECT NO:
All drawings and written material appearing herein constitute
the original and unpublished work of the Sabsy Corporation
and the same may not be duplicated, used or disclosed
without the written consent of the Sabey, Corporation.
3
4
5
6
7
8
9
10
F
E
D
C
t�
A
CUSTOMER APPROVAL: CUSTOMER NOTES:
(Sign Only if 100% Accurate)
(P—e Record & Number ui enongea to tb:e a- omy)
GO
MDO)
HOLDING BEAMS:
99 5f8„
YES
CDO
COLOR:
TORMAX
At
61"
CLEAR '.
AUTOMATIC DOOR SOLUTIONS, L-C.
ORDER # 0038436-001
TX9200SM PG RHSS, (SX-P), 1/4" GLASS,
NO T'HOLD
INTERIOR }
P = s5 3/4
MO = 67
—5x - 63 1
/2-1 EXTERIORS �
PKG. WIDTH = 130 1/4
f26 3J4
9 3/32 HEADER CVR. 7 3J<
3/4 la8V
58 1/4
--Sp =
RAIL 59 1/4
Es>
_ N
P
Y II
m a
u
G
N
1 5/16
4 RAIL
..—__ __— _ 5/i6'1. _. I
2DOOR DETAIL
N.T.S.
NEW AUTOMATIC SLIDING
DOOR. SEE 2/A-101.
INSTALL PER
MANUFACTURER'S
INSTRUCTIONS
NEW CARD READER
RWEJFOR
CODAppROCity of T6UILDING
RECEIVED
CITY OF TUKWILA
NOTE: NEW DOOR TO FAIL TO SAFE IN THE EVENT OF FIRE DEC 0 9 2019
ALARM ACTIVATION, AS REQUIRED BY CODE.
PERMIT CENTER
SABEY
SABEY ARCHITECTURE
12201 Tukwila lot Blvd - 4th Floor Seattle,
WA 98168
206.281.8700
Sabey.com
6114 REGISTERED
A T
KARA M. ANDERSON
STATE Of WASHINGTON
SLIDING DOOR
ADDITION
RIVERFRONT TECHNICAL PARK
2811 S 102ND ST
TULWILA, WA98168
MARK I DATE DESCRIPTION
PROGRESS DATE: 12/9/19
DRAWN BY: TS
CHECKED BY: TS
APPROVED BY: KA
PROJECT NO:
All drawings and written material appearing herein constitute
the odginai and unpublished work of the Sabey Corporation
and the same may not be duplicated, used or disclosed
without the written consent of the Sabey Corporation.
FLOOR CONSTRUCTION
PLAN
1° = 20'-0'
ENLARGED FLOOR PLAN
3 114'=1�0• -
��j � r■jk