Loading...
HomeMy WebLinkAboutPermit S17-0047 - AT&T - BUILDING MOUNTED SIGNAT&T 16425 SOUTHCENTER PKWY S17-0047 BUILDING MOUNTED SIGN Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TulcwilaWA.gov PERMANENT SIGN PERMIT 5379200290 Permit Number: 517-0047 16425 SOUTHCENTER PKWY COMPLEX Issue Date: 8/24/2017 Permit Expires On: 2/20/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Business: Name: Address: ARGUS GROUP/BDS SARM 10500 NE 8TH ST STE 1930, BELLEVUE, WA, 98004 ROBERT SANTOS 1 37TH ST NW , AUBURN, WA, 98001 ADVANCED SIGNS LLC ONE 37TH ST NW, STE C , AUBURN, WA, 98001 ADVANSL923DP AT&T 16425 SOUTHCENTER PKWY Phone: (253) 987-5909 Phone: (253) 347-5039 Expiration Date: 3/23/2018 DESCRIPTION OF WORK: Revised proposal has only 1(one) building mounted sign Fees Collected: $1,062.60 Types of Sign: 1. BUILDING -WALL EXPOSED BUILDING FACE: SIGN AREA (SQ FT): Zoning: TUC Electricity Provided by: PUGEST SOUND ENERGY 1347 22.43 Planning Division Authorized Signature: Date: 8/24/17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Signature: Print Name: ACCEPTANCE BY EMAIL IS SIGNATURE FOR PERMIT AND CONDITIONS Date: 8/24/17 THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. Sign permit inspections are conducted once a month. This allows approximately 30.days for the sign to be manufactured and installed. Please let us know if more time is needed. If payment for the job is pending final inspection approval, please provide the sign permit information by email to max.baker@tukwilawa.gov or call 206-431-3683 and we will complete the inspection within five (5) business days. Electrical permits and inspections occur independent of this permit. FINAL INSPECTION APPROVAL: DATE: City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director July 27, 2017 CORRECTIONS REQUESTED FOR SIGN PERMITTING PROCESS Robert Santos Advanced Signs LLC 1-37th Street Northwest Auburn, WA 98001 Subject: Corrections requested for sign permit S 17-0047-AT&T-located at 16425 Southcenter Parkway, Tukwila WA 98188. Dear Mr. Santos On July 26th, 2017, the Department of Community Development received your application for a sign permit at AT&T located at 16425 Southcenter Parkway, Tukwila WA 98188. Review of the document showed that there were additional corrections needed to the proposal before we could proceed with the sign permitting process. Per the Tukwila Municipal Code, "any period of time during which the applicant has been requested by any City department, agency or hearing body with jurisdiction over some aspect of the application to correct plans, perform required studies, or provide additional information. If the applicant fails to provide a request correction of additional information within 90 days of the request the Department may cancel the application due to inactivity." (TMC 18.104.130-1B). The following corrections are required to this sign permit application: 1. Monument signs must fit within the guidelines presented in the Tukwila Municipal Code. Table 1 under section 19.20.040 of TMC states a premises that has a Right of way that less than 400 feet can have a freestanding monument sign that has a maximum height of 6ft. The monument sign proposed does not fit within these guidelines. 2. Per section 19.20.050 of the Tukwila, "each separate tenant suite with an exterior public entrance is permitted to have one flush -mounted building sign per exterior public entrance." (TMC 19.20.505). This building has one public entrance. Three (3) exterior building signs have been proposed in this permit application, when only one is allowed on the premises. 3. The building is also not larger than 25,000 square feet and does not qualify for an additional flush -mounted building mounted sign. Flush mounted sign on south side of building (S3) will not be permitted at this location. (TMC 19.20.050 A). 4. Sign area calculations for sign S1 and S2 are incorrect. Please review sign application that is attached for instructions on how to calculate total sign area for sign permit applications Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov If you have any further questions or concerns, please do not hesitate to reach out to me. Best Regards, Jonathan Jose Planning Intern Attachments: A -Sign Permit Application Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 PERMANENT SIGNS Building Mounted And Freestanding PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Planner : Needs Elec Zoning of Site: Commercial/Industrial File Number: 1r_cot41._ Associated File Numbers : Residential Number of Building Mounted Signs included in application: Number of Freestanding/Monument Signs included in application: Other signs included in application (Dynamic / Canopy /Awning / Other): AT Text on on sign will read: Name of Tenant: A + Address of Tenant / Business.: 1 (c 1 Z 5 5 C,ti i c EN-ri `Nkkl Contractor: A -IN N\CE1) 4) (rt Contractor State License #: f D\J/ i.. 9i3 Contractor's City of Tukwila Business License #: Contractor Address: 1 7 S t) City if)U1 Ni St \AJA Zip q On 1 S C, Contact Name for Permit: RoT3E ANri- 01 Contact Address: \ — 375T 1\\ t) City AO3at- ki St WAZip cr ffe) 0 1 Contact E-mail: AS1-. SA 1.1-7-05 (2,0'‘3 (-3-7k0 (:d rt Contact Phone: - s9oq HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for the City to revoke the sign permit, 726 2o'i Date: Sig,/ser o uthorized Agent REC7,.117ED JUL 26 au Worksheet for Building -Mounted Signs in Commercial/ ndustrial Zones The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs; see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Wall Sign Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size' of your wall sign: Maximum Sin Area AREA = (L x H) of Exposed Building Face (EBF) in square feet = Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF-500) x .04 + 25 square feet 1501-3,000 (EBF-1,500) x .03+ 65 square feet 3,001-5,000 (EBF-3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet *To meet requirements, please refer to the information and tables provided in this document Sign #1 Sigi Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 A. Q' (useeet ifne1d a1 sis) or Wall Area I 54'0 3 ) 04-1 c/ The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area .- . 5 -1 ..,L.C2 • ) Calculate the maximum sign area allowed for the wall from the table above. Proposed Area of Sign LA , 5 q - S 7face Calculate the area by drawing one box around the entire sign or copy using 90 degree angles. Sign Copy AT 9---r- V 4-- I., 0 (rt. A-+A--r A-1- 9-1- List what the sign will say (for example: name of business). ri rf ir, t ' , ircn JUL 26 1011 This table is inapplicable if your site is covered under an approved Master Sign Program and an increari9OR,area was granted. Incentive Signage Provision Businesses may be permitted additional flush -mounted building signage on walls fronting their tenant spaces that do not qualify for the signage described in Section 19.20.50.A, under the following circumstances: a. The business or use may not have any other building -mounted signage oriented in the same direction as the incentive sign. b. Architectural interest must be provided through at least one of the following methods: 1) At least 50 percent of the wall area between the height of two and seven feet must be transparent with either an unobstructed view into the business or use, or a display window with a depth of at least three feet. 2) Architectural detailing consistent with the building design using changes in color, materials, texture and variations in the wall plane. 3) Artwork such as mosaic, mural or sculptural relief over at least 50 percent of the wall surface. 4) One or more trellises covering at least 50 percent of the wall area between the height of two and seven feet, planted with climbing vines and other plant materials in a planting bed at least two feet in width and provided with permanent irrigation. 5) The allowable area of the sign is 50 percent of that calculated in "Table 22 — Allowable Message Area for Permanent Wall Signs in Commercial and industrial Zones." 2 See table on front side — "maximum sign area" AT&T LOCATION BRANDING DOCUMENT City/State: Tukwila WA Address: 16425 Southcenter Pkwy Creation Date: 06/28/2017 Revised: 07/14/2017 07/28/2017 08/10/2017 08/15/2017 664 RECEIVED AU6 23 2011 Community Development priontysign rtio-r-er Ground Signs Allowed Currently Current Proposed by Code Installed °A Utilized Proposed % Utilized A (%Delta) Height (ft,): 0 0 NA 0 NA 00,0 Number: 1 0 NA 0 NA 00.0 Square Footage (ft.): 0 0 NA 0 NA 00.0 Wall Signs Height (ft.): Number: Allowed Currently Current by Code Installed % Utilized 0 0 NA 2 0 0 Proposed 3.5 Proposed % Utilized NA A (%Delta) 100,0 50 100,0 Square Footage (ft,): 100 0 0 15.6 15,6 100.0 Total Signage Number: Allowed Currently Current by Code Installed % Utilized 3 0 0 Proposed Square Footage (ft.): 100 0 0 1.6 Proposed % Utilized A (%Delta) 100.0 100.0 % Delta is calculated: proposed signage current signage *Square footage of Globe and AT&T letters are calculated as two separate elements. Branding Rationale / Comments Ground Signs Existing: 0 New: 0 R 0 Net Total: 0 Tenant Panel Only Currently Installed? Wall Signs Existing: 1 Ye New: 2 Red: 0 Net Total: 3 Total Primary Signs Existing: 1 New: 2 Revel: 0 Net Total: 3 Each separate tenant suite with an exterior public entrance is permitted to have one flush -mounted building sign per exterior public entrance. Allowed 50 sq ft per sign. ® priontysiqn Reisions; X File Leton: STNQI DrivelClienETA CSTIL AS A CR 0 EN Date: 06/2812017 DesigneAS PMTK R E cEIV ED Au6 23 1011 Community Develnprnent City/Sta: Tukwila/ Address:16425 Soulhcenter Pkwy Drawing # Site Name C5 720 107828 Site ® priontysIgn x x x ' File Ldi: STNQL DrivelChentER CST 0 AS A CR 0 EN Date: 06/2812017 DesigneAS PMTK City/Ste: Tukwilati rip) ZsE > _ w c E 7 a ILI a2 E 0 QcDo CC N Drawing # Site Name 053720 107828 1 Custom Remote Wired Illuminated Letterset Installation Guidelines Remove current lettersets and repair fascia as needed Install new remote wired illuminated globe as shown priorltysign Reisions: X Added seyodimensionsIAS107,11,17 X Raise to IOW I E018,10,17 X Raised to smaller SAS I08,15,17 X AS CR 0 EN Dale: 06/2812017 DesigneAS PMTK :CEVED AU6 231011 Community Development rqtyot;vinki 460a4 kvyijvtuf bI23�1� CitylSie: TukwilaAI Address:16425 Southcenter Pkwy Drawing # Site Name C53720 107028 Custom Remote Wired Illuminated Letterset Installation Guidelines • Remove current lettersets and repair fascia as needed • Install new remote wired illuminated globe as shown Scale I 1/2.11-0" *col ED 06 23 2011 Community Development c) Globe Specifications 1/4"moun/ng spacer 3" .040" aluminum returns painted • MP77101 Blue, 2a) Finish: high reflective white interior surfaces White LED module 1/2" clear acrylic with 3M #3630.7775 Blue film applied first surface to match PMS 299C); 3M #3635-7336 Lt, Blue 'ilrn on second surface 1(4" dia, weep hole with light cover (min. 2 holes per letter) .063" pre -coated white aluminum bath AT&T Letter Specifications .040" aluminum returns painted Matthews MP59262 Black, satin finish. Paint interior surfaces 74200 SP ZAP White Light Enhancement .063" aluminum back; Paint interior surfaces 74200 SP ZAP White Light Enhancement, 112clear acrylic face with 3M #3635-222 Black Perforated Film applied 1s1 surface and 3M #3635.30 Diffuser Film applied 2nd surface While LED module (GELcore White 7100k) 114' dia. weep hole with light cover (min, 2 holes per letter) 411 staple returns to backs 12" .060" formed aluminum power supply enclosure with waterproof cover for access UL listed disconnect single pole with rubber boot 120V power supply 18° flexible conduit Mounting. #10 screws wilh shielded anchors min. 5 per letter Primary electrical source Mounting: #10 screws with shielded anchors min. 5 per letter 114" aluminum spacer 120V power supply 3(8" flexible conduit priontysiqn Roisions: Added sewiimensions /AS I 07,11.17 X Raise to tete / EO I 8.10.17 X Rvised to smalls, tlIS 08,15.17 X File LOtow STK)._ DrvelClienER CSTIL AS A CR 0 EN Date: 06/2812017 DesigneAS PMTK City/Ste: Tukwila* Address:16425 Soulhcenter Pkwy Drawing # Site Name 1 7828