Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M19-0024 - MORRIS RESIDENCE - GAS FURNACE REPLACEMENT
MORRIS RESIDENCE 13518 35TH AVE S M19-0024 �v Parcel No: Address: Project Name: �-^�xx "�� Tukwila "~�~� v�n n ��m"���oa Department of Community Development 630O5outhcenterBoulevard, Suite #1UO Tukwila, Washington 9D18n Phone:206'431'367O Inspection Request Line: 206'438'9350 VVebdte:http://www.TukwUavVA.mov MECHANICAL OTC PERMIT 8864000020 Permit Number: K419'0024 KxDRRBRE5|DEN[E Issue Date: 2/21/2019 Permit Expires On: 8/20/2019 Owner: Contact Person: Name: Address: Contractor: Address: License No: Lender: Name: Address: [NORR|S]|LL l351835THAVE S,SEATTLE,WA, 98168 ]ENN|F[RyNASTERS AAA HEATING &AC([ONSTRUCTIUN) 22641 83RDAVE S'KENT,WA, 98O32 ''' Phone: (253)518-2085 Phone: (253)630-9224 Expiration Date: 11/14/2019 DESCRIPTION OF WORK: REMOVE & REPLACE GAS FURNACE Valuation of Work: $4,500.00 Type ofWork: REPLACEMENT Fuel type: GAS Fees Collected: $213.33 Electrical Service Provided by: SEATTLECITY LIGHT Water District: 125 [ | ^ Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: as Code: Permit Center Authorized Signature: National Electrical Code: vvACities Electrical Code: VVAC29646O: Code: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction ortheperfunnanoeofwmrk. |amauthorized tnsign and obtain this development permitAnd agree to the corij�tions atta_ched to this permit, Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: l: `MECHANICAL PERMIT COND0DNS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (286/43l,3G7O). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source ofignition |s not less than 18 inches above the floor surface unwhich the equipment orappliance rests. 7: Type 1Hoods, the required grease duct leakage test and light test shall beperformed'byaspecial inspection and testing agency |n accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 RDUGH'|MK8E[HAw|[AL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.Tukwi laWA.gov anical Permit No. M q Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 8864000020 Site Address: 13518 35th Ave S, Tukwila, WA 98168 Tenant Name: Suite Number: PROPERTY OWNER Name: Jill Morris Address: 13518 35th Ave S City: Tukwila State: WA Zip: 98168 CONTACT PERSON — communication person receiving all project Name: Jill Morris Address: 13518 35th Ave S City: Tukwila State: WA Zip: 98168 Phone: 206-856-3198 Fax: Email: Floor: New Tenant: EI Yes LI ..No MECHANICAL CONTRACTOR INFORMATION Company Name: AAA Heating & Air Conditioning Address: 22641 83rd Ave S City: Kent State: WA Zip: 98032 Phone: 253-630-9224 Fax: Contr Reg No.: AAAHEHA874QM Exp Date: ii /14/19 Tukwila Business License No.: BUS-0996404 Valuation of project (contractor's bid price): $ 4,500 Describe the scope of work in detail: Remove & Replace Gas Furnace Use: Residential: New El Replacement Commercial: New El Replacement Fuel Type: Electric n Gas Other: H:\Applications\Forms-Applieations On Line\2016 Applications \Mechanical Permit Application Revised I-4-16.docx Revised January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >look btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10.000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/I,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and SAM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; Construction and property maintenance during the daytime hours (7am-lOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction arnount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NEROR AUTHORIZED AGENT: Signature: "MtiAVA/b Print Name: Jennifer Masters - AAA Heating & AC Mailing Address: 22641 83rd Ave S Date: 2/21/19 Day Telephone: 253-630-9224 Kent City WA 98032 State Zip HAApplicanonskForms-Applications On Line \2016 Applications \Mechanical Permit Application Revised 1-4-16.docs Revised: January 2016 bh Page 2 of 2 ceipt Number R16937 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $276.33 EL19-0165 Address: 13518 35TH AVE 5 Apn: 8864000020 $63.00 ELECTRICAL $60.00 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $60.00 TECHNOLOGY FEE $3.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.00 M19-0024 Address: 13518 35TH AVE S Apn: 8864000020 $213.33 MECHANICAL $203.17 PERMIT FEE R000.322.100.00.00 0.00 $170.02 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16937 R000.322.900,04.00 0.00 $10.16 $276.33 Date Paid: Thursday, February 21, 2019 Paid By: AAA HEATING & AC INC Pay Method: CHECK 5177 Printed: Thursday, February 21, 2019 10:40 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit CCf INSPECTION NO. PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 tu Project:y�/j,��,, �� Type of Inspection: Address: (35 /j Date Called: 5pecial Instructions: Ft'(Requester: Date Wanted: e.. cf G' Phone No: 7A__ 915S-1- Approved per applicable codes. Corrections required prior to approval. ENTS ns pec Date: REINSPECTION FEE REQUIRE©. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. AAA Heating & AC Page 1 of 2 Houle Espanol Contra Safety & Health Washington State Department of Labor & Industries Claims & Insurance !Search L&I A-Z index Help Workplace Rights AAA Heating & AC Owner or tradesperson Principals Cartwright, Shaun P, PRESIDENT Kowalenko, Victor, VICE PRESIDENT Doing business as AAA Heating & AC WA UBI No. 601 882 148 Parent company AAA HTG REFRIGERATION INC 22641 83RD AVE S KENT, WA 98032-1990 253-630-9224 KING County Business type Corporation Governing persons VICTOR KOWALENKO JAN ANGELA KOWALENKO; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. AAAHEHA874QM Effective — expiration 11/14/2013-11/14/2019 Bond Cincinnati Ins Co Bond account no. 0552591 Received by L&I 11/14/2013 Insurance Firemans Ins Co of Washington Policy no. CPA6029029 Received by L&I 11/02/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsults against the bond or savings $12,000.00 Effective date 10/18/2013 Expiration date Until Canceled $1,000,000.00 Effective date 11/01/2018 Expiration date 11/01/2019 My L&.I Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601882148&LIC=AAAHEHA874QM&SAW= 2/21/2019