Loading...
HomeMy WebLinkAboutPermit M19-0033 - MUTUAL MATERIALS - SPLIT SYSTEM HEAT PUMPS, EXHAUST FAS AND ELECTRICAL WALL HEATERSMUTUAL MATERIALS 4302 S 1O4T" PL M19-0033 Parcel No: City k"°" U �� Department -= Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 90188 Phnne:286-431'3670 Inspection Request Line: 206-438'9350 Web site: h1tp///vxmmv.Tukmi|aVVA'xpv [823O4921] Project Name: MUTUAL MATERIALS MECHANICAL PERMIT Permit Number: M19'0033 Issue Date: 4/16/I019 Permit Expires On: 10/12/3019 Owner: Name: Address: Contact Person: Address: Contractor: Address: License No: Address: MUTUAL MATERIALS COMPANY HEATH HAMBLEN 4102 B PLACE NW, AUBURN, WA, 98001 UNIVERSAL REFRIGERATION INC (0DNST) POBOX 614'AUBURN, WA, 9D071- O614 ''^ Phone: (253)939'5501 Phone: (253)939-5501 Expiration Date: 4/1/I820 DESCRIPTION OF WORK: REMOVE EXISTING AIR CONDITIONING SYSTEM AND REPLACE WITH (4) SEPARATE SPLIT SYSTEM HEAT PUMPS. INSTALL NEW EXHAUST FANS IN RESTROOMS WITH ELECTRIC WALL HEATERS FOR COMFORT. Valuation ofWork: $55'822.00 Type ofWork: REPLACEMENT Fuel type: ELECT Fees Collected: $957.5I Electrical Service Provided by: SEATTLECITY LIGHT Water District: TUKVVLA Sewer District: TUKWILA Current Codes adopted bythe City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 20152015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[296-46B: VVAState Energy Code: 2017 2017 2,017 2015 Permit Center Authorized Signature: _~[T~ / �L� \ �-~| -/ �--N I hearby certify that I have read and examined this permit and know the same to be true and correct, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. | am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: This permit shall become null and void ifthe work isnot commenced within 18Odays for the date cfissuance, orif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based unsatisfactory completion ofthis requirement. G: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City nfTukwila Building Department (2O6'4]1'367O). G; All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ufapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: `MECHANICAL PERMIT CONDITIONS' 9: All mechanical work shall beinspected and approved under Permit Center (]06/4]1-367O. 10: Manufacturers installation instructions shall beavailable on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438'9350 0703 1800 0609 0705 0701 K8E[HEQUIP EFF MECHANICAL FINAL P|PBDU[T|N5ULAT|ON REFRIGERATION EQUIP ROUGH'|NK8ECMAN|[AL a separate permit issued by the City of Tukwila the job site atthe time cfinspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION t4302_ -3, Site Address: Ogll Aft..1-; Tenant Name: rtAkA•un. t VAAVULI King Co Assessor's Tax No.: 05 Z5 014 - q?-1 Suite Number: Floor: New Tenant: .....Yes D ..No PROPERTY OWNER Name: F. wiruAt vv‘ixi-uci A iS Address: tob5 i q ,N E. City:.--, 1 belt E.N) t.i..e State: cs(\ Zip:crg CONTACT PERSON — person receiving all project communication Name: eath Hamblen ryan Galvin Chuck Stephen Address: w City: Auburn98001 State: WA Zip: Phone: (253) 939-5501 Fax: (253) 735-3432 Email: universalrefrig.com MECHANICAL CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B PL NVV City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax (253) 735-3432 Contr Reg No.: uNivEm 159RF Exp Date: 04/01/2019 Tukwila Business License No.: BUS-0993124 Valuation of project (contractor's bid price): $ 551512. Describe the scope of work in detail: HVACR Mechanical, install ( ) 1-41•Acv‘ ”v) N.1 (.0•5t7?\ 4.1Aqs VP\ A" •Dlibkita•A 1,AE NV -et, VNA.'"e . 7 ,..y,l,p,A kie,0 ty,k4(kugo‘- rNWire0 C- 1..10..\\ 10164;i\C'UZ-gl. et- C.01,A4. 0.A. . Use: Residential: New 0 Replacement 0 Replacement Commercial: New Fuel Type: Electric__ E 5ti1"tA ".ft) .Rbs\ NY.> 4-7-L-SV(Z-00v.A4) 0.44 Gas 0 Other: H \ A ppli cat o ns Fo rms - A pp I i ca io ns On Line \2016 ApplicationsWlechanical Permit Application Revised I -4•16,docx Revisod: January 2016 bh Page 1 of 2 '‘Ilneare Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment flu . ISA Utz4 - Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/i,750,000 btu 50+ hp/I ;750,000 btu Noise: • , Mechanical units need to be in compliance with the Tukwila Noise Code. Maxinium permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house.at night in a -residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB A ,- . 65 dB(A). Industrial 60 dB(A) 50 dB(A) 65 dB(A) . ' 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. *; A few sounds are exempt from the noise code, including: • Warning devices; Construction and property maintenance during the daytime hours (7am-10pm); - Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated, Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF,WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW N ZED AGENT-• . • Signature: Date: Si (11. Print Name: Jerry Aesc11imann or Aidan Wilson Day Telephone: (253) 939-5501 Mailing Address: 4102 B PL NW AUBURN WA 98001 City ' State Zip H:1Applications Wonns-Applications On Line12016 ApplicationsNechanical Pemni Application Revised 1-4-16.doca Revised: January 2016 bh Page 2 of 2 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $957.52 . M19-0033 Address: 4302 S 104TH PL Apn: 0 23049213 $957.52 MECHANICAL $920.69 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $703.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $184.14 TECHNOLOGY FEE $36.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17082 R000,322.900.04.00 0,00 ' $36.83 $957.52 Date Paid: Tuesday, March 05, 2019 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 54235 Printed: Tuesday, March 05, 2019 11:23 AM 1 of 1 SYSTEMS �003,3 INSVECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431- Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Pro "ecctt:Y Type a Inspectionger j[a Or Address: e Called: Special Instructions: DaQte nted : G1 9 Requester: Phone No: zs- Approved per applicable codes. Inspector: Corrections required prior to approval. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6300 Perm INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION uthcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 inspection Request Line (206) 438-9350 Project: /(/� Type of Ins ection: Address: t x., Date Called: 5 ecial lns uctions: .ve:,wc... -art �."`'"'3 Date Wanted: a.war* Requester: Phone No: Z9,9g9 5 proved per applicable codes. Corrections required prior to approval, COMMENTS: Inspector: Date: REINSPECTIO EE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspeclion. UNIVERSAL REFRIGERATION HEATING 1 AIR 1.0NOMONING Heating Air Conditioning Refrigeration Contractors Lic# ONIVERI*159RF Oregon Lid/ 160248 REVIEVvtD FOR CODE COMPLIANCE APPROVED MAR 08 2019 City of Tukwila BUILDING DIVISION FILE 0 utual Materials T.I. Tukwila, WA 98118 HVAC Submittals c.„ Martin Luther King Jr. S. AMP • To: Northway Construction, Inc. From: Universal Refrigeration, Inc. Heath Hamblen M 61 003 3 RECEIVED CITY OF TUKWILA MAR 05 2019 PERMIT CENTER P.O. Box 614 • 4102 "B" PL NW • Auburn, WA 98071 Seattle: (253) 839-2126 • Tacoma: (253) 922-3141 • Auburn: (253) 939-5501 • Fax: 253) 735-3432 Table of Contents 1. Daikin Split System Heat Pumps: IHP-1 & OHP-1, IHP-1A, IHP-2A, IHP-3A & OHP-1A IHP-1B, IHP-2B, IHP-3B & OHP-1B IHP-1C, IHP-2C, IHP-3C & OHP-1C 2. Daikin Temperature Controllers 3. Exhaust Fans: EF-1 thru EF-5 4. King Electric Wall Heaters: EWH-1 thru EWH-4 1. Daikin Split System Heat Pumps: IHP-1 & OHP-1 IHP-1A, IHP-2A, IHP-3A & OHP-1A IHP-1B, IHP-2B, IHP-3B & OHP-1B IHP-1C, IHP-2C, IHP-3C & OHP-1C r • r r r LJ r L • I _J LJ r 1 L J L L_ r r-1 Job Name: Mutual Materials T.I. Tag# IHP-1 &OHP-1 DA IKIN Submittal Data Sheet FTXI8NMVJU / RX18NMVJU 1.5-Ton Wall Mounted Heat Pump System Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Indoor Specifications Cooling Heating H M H Airflow Rate (cfm) 713 579 745 604 SL 1. SL 448 403 470 420 Sound (dBA) H/M/L/SL 49/44/38/33 49/42/37/33 Dimensions (H x W x D) (in) 11-5/8 x 39 x 10-3/8 Weight (Lbs) 27 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 2.49 Refrigerant Oil PVE (FVCSOK) Cooling Heating Airflow Rate (cfm) H 2,461 H 2,217 SL 2,108 SL 1,896 Sound Pressure Level (dBA) 54 Dimensions (H x W x D) (in) 28-5/16 x 34-1/4 x 12-5/8 Weight (Lbs) 97 Efficiency Cooling Heating SEER 18 HSPF 9.0 EER 12.5 COP 3.60 Performance Cooling (Btu/hr) Rated (Min/Max) 18,000 (5,500 / 20,000) Sensible @ AHRI 14,480 Moisture Removal gal/h 1.0 Standard Operating Range 50°F — 115°F Extended Operating Range* -4°F — 115°F Rated Cooling Conditions: Indoor: 80°F DB/677 WB Outdoor: 95°F DB/75°F WB *With field settings and wind baffle Heating (Btu/hr) 1:@ 47° Rated (Min/Max) 21,600 (5,500 / 24,000) 2: @ 17° Rated 13,000 3: @ 5° 9,650 Operating Range 5°F — 65°F 1: Rated Heating Conditions: 2: Rated Heating Conditions: 3: Heating Conditions: Indoor: 70°F DB/60°F WB outdoor:47°F DB/43°F WB Indoor: 707 DB/60°F WB Outdoor: 17°F DB/15°F WB Indoor: 70°F DB/60°F WB Outdoor:5°F DB/5°F WB Electrical 208/60/1 230/60/1 System MCA 18.3 18.3 System MFA 20 20 Compressor RLA 10.8 10.8 Outdoor fan motor FLA .45 .45 Outdoor fan motor W 69 69 Indoor fan motor FLA .30 .30 Indoor fan motor W 46 46 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 1/2 Drain (in) 5/8 Max. Interunit Piping Length (ft) 98.4 Max. Interunit Height Difference (ft) 65.625 Chargeless (ft) 32.8 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information In this data sheet without notice and without incurring any obligations) Submittal Revision Date: September 2018 Page 1 of 4 FT BOTTOM THE MARK (--) SHOWS PIPING DIRECTION REAR 39 (990mm) FRONT GRILLE FIXING SCREWS (INSIDE) HT E E N NCLUDING „MOUNTING PLATE! 10.7/16 (265mm 1-15/16 (50mm) MINI (SPACE FOR NERAL RATING MAINTENANCE) ME RATE RMINAL BLOCK TH EARTH TERMINAL (INSIDE) UP AND DOWN WIND DIRECTION CONTROL BLADE MOVABLE RANGE GAS PIPE 01/2 (012 7m SIGNAL RECEIVER OPERATION LAMP TIMER LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) MODEL NAME PLATE CD-- SIGNAL TRANSMITTER BLADE ANGLES 1.7/8 (46mm) (2kril) UP/DOWN (AUTOMATIC) COOLING, DRY HEATING •6666666..416. E 0 WIRELESS REMOTE CONTROLLER \ (ARC4B0A8) RIGHT/LEFT (MANUAL) 5•.0 CuT 4 AIR FLOW (INDOOR) REQUIRED SPACE ABOUT 15•3/4 (400mm) ABOUT 17.5116 (440mm BOUT 18.1/8 460mm DRAIN HOSE LIQUID PIPE 0/4 (6.4mm) CuT (CONNECTING PART I.D. u9/16414mml o5/8 (o16mm) FAN E 39 E 1. (,) ‘,0 w 0 ccz < 0 2 u. cc Lu 0 u. < Lt w cn a. 1.15/16 (50mm) MIN (SPACE FOR MAINTENANCE) DRAIN HOSE GAS PIPE LIQUID PIPE ABOUT 14-3I16 (36thri) ABOUT 14.3/8 (365mm) ABOUT 17.3/4 (450mm) DPIPING248 (6Onm STANDARD LOCATIONS OF WALL HOLES 26.5nr) WALL HOLE 03.1/8 (080mm) HOLE 3D091779 0 •c w .r ro ro '0 c 0 c o c o c o c 2 ,L4 o 0 0 — LA 0 0 ro • a to c lk 0 V E ,E ,,, 0 In t 3 u gj _1 -0 c to 63 (1) ? E ° c o z c • w ,> n • 0 C N O .0 • E 2 ct+ 7 '41 C o 2 2 a To • p, 'c E Fld 0 VI J L. 4; r- 1 r- J r - A, 6 O 0 • E 0 Z co HANDLE 4-HOLES FOR FOUNDATION BOLTS (MS OR M10) GROUNDTERMINAL SERVICE PORT 6 (173) L QUID STOP VALVE fwa (06.4) CuT) GAS STOP VALVE (0112 412.7) CuT) IN CASE OF REMOVING STOP VALVE COVER AND TERMINAL STRIP COVER 23.518 (600) 20.11116 (525) 4.15/16 (125 DRAIN OUTLET (LD.o518 (o15,9) HOSE FOR CONNECTION WITH DRAIN JOIN ELECTRIC WIRE INTAKE FACTURER'SLABE 9/16 (14.5) 13.518 (346) 7/16 (INSTALLATION LEG PITCH) 14.1/2 (368) } 3/4 (19, MINIMUM SPACE FOR AIR PASSAGE yemaammiaigaaa :;) ► OUTDOOR AIR THERM' TOR WALL HEIGHT ON AIR OUTLET SIDE :LESSTHAN 47.1/4 (1200) viaamaviu/imams 0 UNIT: inch (mm) C: 3D092224 0 L L m w 0 m m m a c 0 0 E 0 c c N c 0 r 0 r X 0 a N • C o C 0 -005 0 a) to 0r= u o c ,l2m v a c Tu LL O u oEc v,o; 0 NLL J U c uNym v�« Evo N c L c 1. im ° jy oc ov v 0 3 co 0 C 0 N 0 u E o u a a)m E 7 N mm o m c 0 u 7 5 v 0 c' a m m u N J J _ L L. I r L I r-: L. r LJ LJ fl L I r L. 1 L_ 4-J r 1 Optional Accessories r/DAIKINI Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adapter (S21 Adapter Included) BRC944B2-A08 Wired Remote Controller kit (Adaptor Required) BRCW901A08 Wired Remote Controller Cable — 25ft (Included in above kit) BRCW901A03 Wired Remote Controller Cable — 10ft KRP980B2 Adaptor for wired remote controller (18 & 24) KAF970A45 Titanium apatite photocatalytic air -purifying filter WITH frame KAF970A46 Titanium apatite photocatalytic air -purifying filter WITHOUT frame DACA-CPI-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S + KRP980B2 Interface Adaptor for Dill -NET Outdoor Unit Included Part Number Description DACA-WB-1 Powder -Coated Wall -Mounted Bracket KPW063A4 Air direction adjustment grille (18 & 24) KEH063A4E Daikin BML DraM Pan Heater Large RX18,24 & RXNI 8,24 KKG063A42 Back protection wire net (18 & 24) KKP937A4 Drain Plug for OD Unit Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: September 2018 Page 4 of 4 r r 1 J Job Name: Mutual Materials T.I. Tag# IHP- IC DAIKIN Submittal Data Sheet FTXSO9LVJU .75-Ton Wall Mounted Indoor Unit Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Electrical .208/230V Cooling Heating Running Current (Rated) (A) .09/.08* .11/.10* Power Consumption (Rated) (W) 18/18* 21/21* Indoor Specifications Cooling Heating H M H Airflow Rate (cfm) 381 279 420 321 1 SL L SL 194 145 233 219 Sound (dBA) H/M/L/SL 41/33/25/22 42/35/28/25 Dimensions (H x W x D) (in) 11-5/8 x 31-1/2 x 8-7/16 Weight (Lbs) 20 Nominal Capacity (Btu/hr) 9,000 *See Outdoor Unit for Rated Capacities Piping Liquid (in) 1/4 Gas (in) 3/8 Drain (in) 5/8 Optional Accessories Included Part Number Description BRP072A43 Wireless Interface Adapter (S21 Adapter Included) DACA-TS-1 Daikin ENVi Intelligent Thermostat Kit BRC944B2-A08 Wired Remote Controller Kit (Includes BRC944B2 & BRCW901A08) BRCW901A03 Wired Remote Controller Cable - 10 ft (For BRC944B2) BRCW901A08 Wired Remote Controller Cable - 25 ft (For BRC944B2) KRP928BB2S Interface adaptor for DIII-NET DACA-CPI- I Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump KAF925B42 Air -purifying filter with photocatalytic deodorizing function (without frame) Dalkin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continbous Improvements. Dalkin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2018 Page 1 of 2 LEFT THE MARK (-+) SHOWS PIPING DIRECTION 31.1/2 (800mm) REAR BOTTOM+ SIGNAL EIVER RIGHT ( INCLUDING 1 MOUNTING PLATE 8-9116 (217mm) < 8-711 INTELLIGENT EYE SENSOR OPERATION (IMP TIMER LAMP INTELLIGENT EYE LAMP OAIRFLOW (INDOOR)'/r 1-15/16 (50mm) MIN (S M REQUIRED SPACE MAINTENANCE) {Sp NAME PLATE TERMINAL BLOCK WITH GROUND TERMINAL INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) MODEL NAME PLATE SIGNAL TRANSMITTER BLADE ANGLES 11116 (18mm) UP/DOWN (AUTOMATIC) COOLING, DRY HEATING FAN WIRELESS REMOTE CONTROLLER (ARC452A21) 70° 65' 0 �, 30''� 65° so* RIGHULEFT (AUTOMATIC) 1-15/16 (50mm) MIN E FOR MAINTENANCE) GAS PIPE 48 ($9,5mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 13-3✓4 (350mm)) UOUID PIPE o114 (46,4mm) CuT .. (THE LENGTH OF PIPE OUTSIDE THE UNIL ABOUT 15-3/4 (480mm)) i E E 8 10 DRAIN HOSE (CONNECTING PART O.D, p58 (o16mm) THE HOSE LENGTH OF OUTSIDE THE UNIT IS APPROX.18.5116 (465mm)) -1/2 (800mm) _____ -------______ — WALL FOR WALL HOLE !2'91 EMBEDDED PIPING 6I5, 2-55l16 99 i5, 0299/16 (065mm) HOLE STANDARD LOCATIONS OF WALL HOLES r 1 C:3D074094A c ro c 0 u« �ro o N xv Fn 0m 0 c o;; ©.0ro N 0 m N 0 N v 10 ro a L . 1 r L_ I : 4._ 4 L J - L .J Job Name: Mutual Materials T.I. Tag# IHP- IA, 2A & 3C DAIKIN Submittal Data Sheet FTXS 1 2LVJU 1-Ton Wall Mounted Indoor Unit Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Electrical '208/230V Cooling Heating Running Current (Rated) (A) .13/.12* .14/.13* Power Consumption (Rated) (W) 26/26* 28/28* Indoor Specifications Cooling Heating H M H M Airflow Rate (cfm) 403 307 438 335 1. SL L SL 205 155 240 212 Sound (dBA) H/M/L/SL 45/37/29/23 45/39/29/26 Dimensions (H x W x D) (in) 11-5/8 x 31-1/2 x 8-7/16 Weight (Lbs) 22 Nominal Capacity (Btu/hr) 12,000 'See Outdoor Unit for Rated Capacities Piping Liquid (in) 1/4 Gas (in) 3/8 Drain (in) 5/8 Optional Accessories r/DAIKINI Included Part Number Description BRP072A43 Wireless Interface Adapter (S21 Adapter Included) DACA-TS-1 Daikin ENVi Intelligent Thermostat Kit BRC944B2-A08 Wired Remote Controller Kit (Includes BRC944B2 & BRCW901A08) BRCW901A03 Wired Remote Controller Cable - 10 ft (For BRC944B2) BRCW901A08 Wired Remote Controller Cable - 25 ft (For BRC944B2) KRP928BB2S Interface adaptor for DIII-NET DACA-CPI-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump KAF925B42 Air -purifying filter with photocatalytic deodorizing function (without frame) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2018 Page 1 of 2 LEFT { THE MARK (—)) SHOWS PIPING DIRECTION 31.1/2 (800mm) REAR BOTTOM RIGHT FRONT GRILLE FIRED SCREWS N (INSIDE) SIGNAL RECEIVER MODEL NAME ��-- SIGNAL TRANSMITTER 2.5116 (58mm) 11116 (18mm) UP/DOWN (AUTOMATIC) COOLING, DRY WIRELESS REMOTE CONTROLLER (ARC452A21) INCLUDING MOUNTING PLATE 8•9116 (217mm) 871 16 (215mm) INTELLIGENT EYE SENSOR OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) PLATE BLADE ANGLES AIRFLOW (INDOOR) r 1.15/16 (50mm) MI (SPACE FOR MAINTENANCE) REQUIRED SPACE (SPA ME PLATE TERMINAL BLOCK WITH GROUND TERMINAL HEATING FAN RIGHT/LEFT (AUTOMATIC) GAS PIPE 0318109,5rmi) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ASCOT 134 (350mn)) LIQUID PIPE 6114 (06,4mm) CuT E(THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15.34 (400n m)) 31 DRAIN HOSE (CONNECTING PART O,D, 65/8 (o16mm) THE HOSE LENGTH OF OUTSIDE THE UNIT IS APPROX.18.5116 (465mm)) 800mm) 1/16 mm) •3t4 (145,5mm E E 2.318 (60mm)^ WAIL HOLE FOR EMBEDDED PIPING 02.9116 ($65mm) HOLE WALL HOLE 62.9116 (685mm) HOLE 2.5116 (59.5mm), STANDARD LOCATIONS OF WALL HOLES C: 3D074094A • N 7 a 0 0 t N m « 0 01 a a, L 0 U c 0 E 0 0 '0 c 0 c 0 N al O u xa C e O 40 7v^ 0'c 070 0'0 m in 0_ 0 • 0 • m nEm LL 0 2 cru mc .1 L 0 Lfl • 013 H C L w .`4) 0 C 0 Z cv YE "4v 0 0 a E 0 c 0 0 0 0 ✓ c CO O h; 0 0 • c u 3 0 W a o p • E m 0 r r l J , r 1 it 7 5.. I I LJ 1'7 6 7 Job Name: Mutual Materials T.I. Tag# IHP-3A, 2B & 3B DAIKIN Submittal Data Sheet FTXS 1 5 LVJU 1.25-Ton Wall Mounted Indoor Unit Complete warranty details available from your local dealer or at www,daikincomfort,com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Electrical *208/230V Cooling Heating Running Current (Rated) (A) .31/.29* .31/.29* Power Consumption (Rated) (W) 38/38* 38/38* Indoor Specifications Cooling Heating H M H M Airflow Rate (cfm) 568 477 593 505 1. SL 1 SL 385 360 417 371 Sound (dBA) H/M/L/SL 45/40/35/32 43/38/33/30 Dimensions (H x W x D) (in) 13-3/8 x 41-5/16 x 9-3/4 Weight (Lbs) 31 Nominal Capacity (Btu/hr) 15,000 *See Outdoor unit for Rated Capacities Piping Liquid (in) 1/4 Gas (in) 1/2 Drain (in) 5/8 Optional Accessories VIDAIKIS Included Part Number Description BRP072A43 Wireless Interface Adapter (S21 Adapter Included) DACA-TS-1 Daikin ENV i Intelligent Thermostat Kit BRC944B2-A08 Wired Remote Controller Kit (Includes BRC944B2 & BRCW901A08) BRCW901A03 Remote Controller Cable - 10 ft (For BRC944B2) ' BRCW901A08 Remote Controller Cable - 25 ft (For BRC944B2) KRP928BB2S Interface adaptor for Dill -NET DACA-CPI-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 Extemal Condensate Pump KA F970A46 Air -purifying filter with photocatalytic deodorizing function (without frame) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77055 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without J notice and without incurring any obligations) Submittal Revision Date: January 2018 Page 1 of 2 THE MARK )SHOWS PIPING DIRECTION 4 1 -tI 4 1 BOTTOM FLAPS i SIGNAL RECEIVER SIGNAL TRANSMITTER 2.5/16 58mm) 11/16 18mm) 10 WIRELESS REMOTE CONTROLLER (ARC452A21) [AIRFLOW (INDOOR) /////////////////////f///////// INCLUDING ,INSTALLATION PLATE 9.13116 (250mm 9 3t4 (248mm) FRONT RILE FIXING SCREWS ro (INSIDE) cc:.,) INTELLIGENT EYE SEN OPERATION LAMP TIMER LAMP J MIN.1.15116 (50mm) 0 MIN.1.15/16 (50mm)) (SPACE FOR REQUIRED SPACE (SPACE FOR NAME PLATE MAINTENANCE) MAINTENANCE) TERMINAL BLOCK WITH GROUND TERMINAL (INSIDE) OR GAS PIPE 0 /2 (012.7mm) CuT (THE LENGTH OF PIPE OUTSIDE SWITCH THE UNIT, ABOUT 15-3/4 (400mm)) ROOM TEMP. THERMISTOR LIQUID PIPE 01/4 (06,4mm) CuT (INSIDE) (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18.1/8 (460mm)) MODEL NAME PLATE E BLADE ANGLES E UP/DOWN (AUTOMATIC) COOLING, DRY 30c RIGHT/LEFT (AUTOMATIC) INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF HEATING FAN i0 E a DRAIN HOSE (CONNECTING PART O.D. o5/8 (016mm) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 18-5/16 (465mm)) 41.5/16 (1050mm) 37-5/16 (947mm) .JS, WALL HOLE FOR EMBEDDED WALL HOLE PIPING 1/8 (080mm) HOLE 03-118 (090mm) HOLE] 2.9116 (65mm) 3-112 (8910101 STANDARD LOCATIONS OF WALL HOLES 1-3/8 (35.5mm) 10 E 0: 3D074024A " N 7 w 0 L • N 3 00 f0 0J 0. 01 0 01 H c 0 E c 10 c 0 N 10 O u N Xa' • a C C O 00 N N 7W;� o c o� o .. � 0_ • a� 0 VI 0 C n•Em LL o t " cu A>L 1o0C ri VI 0 7 NFL j c a �y C [ V 0 L0c O 0 z� cv Y 6; O p E N 7 0 7 • CO c o o N Ot M 01 C a ; � • iV v " C 0 H ▪ 5 m � m E 2 0 L Y r : 17 1 r r 6 I L_J r r r r 4 Job Name: Mutual Materials T.I. Tag# IHP-1B /DAMN Submittal Data Sheet FTXS 1 8 LVJ U 1.5-Ton Wall Mounted Indoor Unit * ptJ vgAn UHT" 'NAV A TY Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Electrical .208/230v Cooling Heating Running Current (Rated) (A) .32/.30* .32/.30* Power Consumption (Rated) (W) 38/38* 38/38* Indoor Specifications Cooling Heating H M H M Airflow Rate (cfm) 583 484 625 526 SL 1 SL 385 360 431 399 Sound (dBA) H/M/L/SL 46/41/33/33 45/40/35/32 Dimensions (H x W x D) (in) 13-3/8 x 41-5/16 x 9-3/4 Weight (lbs) 31 Nominal Capacity (Btu/hr) 18,000 'See Outdoor Unit for Rated Capacities Pipin Liquid (in) 1/4 Gas (in) 1/2 Drain (in) 5/8 Optional Accessories DAIKIS Included Part Number Description BRP072A43 Wireless Interface Adapter (S21 Adapter Included) DACA-TS-1 Daikin ENVi Intelligent Thermostat Kit BRC944B2-A08 Wired Remote Controller Kit (Includes BRC944B2 & BRCW901A08) BRCW901A03 Wired Remote Controller Cable - 10 ft (For BRC944B2) BRCW901A08 Wired Remote Controller Cable - 25 ft (For BRC944B2) KRP928BB2S Interface adaptor for Dill -NET DACA-CPI -1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) . DACA-CP4-1 External Condensate Pump KAF970A46 Air -purifying filter with photocatalytic deodorizing function (without frame) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2018 Page 1 of 2 SIGNAL TRANSMITTER 2.5116 (58mm) 11116 18mm) WIRELESS REMOTE CONTROLLER (ARC452A21) THE MARK ( -0 )SHOWS PIPING DIRECTION LEFT 1 REAR 41.5/16 (1050mm) RIGHT F PS SIGNAL RECEIVER [AIRFLOW (INDOOR) (INCLUDING INSTALLATION PLATE 9.13116 (250mm) ONT E RILLE 0 XING c°n REWSc�w (INSIDE) c •3/4 (248mm) INTELLIGENT EYE SENSOR OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH `ROOM TEMP, THERMISTOR (INSIDE) MODEL NAME PLATE BLADE ANGLES ///////1/////////////l////////1/ U/////////////////////////// T— t 1 3 1 1 l 1 L— / E E %� r, Z J iW^ s 4, b ( r MIN.1.15/16 (50mm) 0 MIN.1.15116 (50mm) NAME PLATE TERMINAL BLOCK WITH GROUND TERMINAL (INSIDE) UP/DOWN (AUTOMATIC) COOLING, DRY HEATING FAN RIGHT/LEFT (AUTOMATIC) (SPACE FOR REQUIRED SPACE (SPACE FOR MAINTENANCE) MAINTENANCE) GAS PIPE /2 (012.7mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15.3/4 (400mm)) LIQUID PIPE 01/4 (A6,4mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18.1/8 (460mm)) E E DRAIN HOSE (CONNECTING PART O.D. 0518 (A16mm) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 18-5116 (465mm)) 41.5/16 (1050mm) 37.5/16 (947mm) w 0 z 0 CC u O. 1-3/8 (35.5mm) WALL HOLE FOR EMBEDDED WALL HOLE PIPING 03-118 ( 'mm) HOLE 03.1/8 (OBOmm) HOLE 2.9/16 (65mm) 3-1/2 (89mm) STANDARD LOCATIONS OF WALL HOLES E E E ro C: 31)074024A w 0 0 00 @ a CO 0 N c 0 « @ c 0 .N .5 cc 7a E — L J a I { • r 1 L � J I, A r 7 r 1 r- L I L A Job Name: Tag# Mutual Materials T.I. IHP-2C 1 Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Electrical "208/230V Cooling Heating Running Current (Rated) (A) .57/.51* .57/.51* Power Consumption (Rated) (W) 69/68* 69/68* DAIKIN Indoor Specifications Cooling Heating H M H Airflow Rate (cfm) 643 494 699 572 L SL L SL 350 328 445 403 Sound (dBA) H / M / L / SL 51/44 /37/34 48/42/37/34 Dimensions (H x W x D) (in) 13-3/8 x 41-5/16 x 9-3/4 Weight (Lbs) 31 Nominal Capacity (Btu/hr) 24,000 •See Outdoor Unit for Rated Capacities Piping Liquid (in) 1/4 Gas (in) 5/8 Drain (in) 5/8 Optional Accessories VDAIKIN1 Included Part Number Description BRP072A43 Wireless Interface Adapter (S21 Adapter Included) DACA-TS-1 Daikin ENVi Intelligent Thermostat Kit BRC944B2-A08 Wired Remote Controller Kit (Includes BRC944B2 & BRCW901A08) BRCW901A03 Wired Remote Controller Cable - 10 ft (For BRC944B2) BRCW901 A08 Wired Remote Controller Cable - 25 ft (For BRC944B2) KRP928BB2S Interface adaptor for Dill -NET DACA-CPI-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump Daikin North America LLC 51.515an Felipe, Suite 500 Houston, TX 77056 • (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2018 Page 1 of 2 To 0 "N a) E 0 -J X I II 1� FLAPS SIGNAL RECEIVER SIGNAL TRANSMITTER 2.5/16 (58mm) 11116 (18mm) LEFT THE MARK (-) SHOWS PIPING DIRECTION REAR 41.5116(1050mm) -.110°.-M1 AIRFLOW (INDOOR) 'RIGHT INCLUDING INSTALLATION PLATE 9.13116 (250mm) 9 314 (248mm) BOTTOM E WIRELESS REMOTE CONTROLLER (ARC452A21) ONT E RILLE o FIXING g CREWS NSIDEI iiii/aiariiarriaaiiiiaira1/iaia/iiiaii/riia/iaiiii/ j `1 1 1 1 1 T i E .D r/ %m 5 bz MIN, 1-15/16 (50mm) 0 MIN.1.15/16 (5Omm) j (SPACE FOR REQUIRED SPACE (SPACE FOR NAME PLATE MAINTENANCE) MAINTENANCE) "TERMINAL 8L00( WITH GROUND TERMINAL (INSIDE) INTELLIGENT EYE SENSOR OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP, THERMISTOR (INSIDE) MODEL NAME PLATE BLADE ANGLES UP/DOWN (AUTOMATIC) COOLING, DRY RIGHT/LEFT (AUTOMATIC) HEATING 1 GAS PIPE o5/8 (015.9mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15-3/4 (400mm)) LIQUID PIPE 0114 (06.4mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18.118 (460mm)) ..r!L WALL HOLE FOR EMBEDDED WALL HOLE PIPING 03-118 (.'mm) HOLE 03118 (080mm) HOLE 2.9116 (65mm) 3-112 (89mm) W 0 ccZ a oa QLL a¢ NW a DRAIN HOSE (CONNECTING PART O.D. o5/8 (416mm) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 18.5116 (465mm)) STANDARD LOCATIONS OF WALL HOLES C: 3D073962A 0 0 E 0 0 a E 7 0 7 M c 0 u �0+ 0 v 7 ro 0 a 41 0 N w 0 m a m 4- 0 CO CO « 0 c 0 0 7 0 J i , a i • : J y r r r r O. A fl Job Name: Mutual Materials T.I. Tag# OHP- IA DAIKIN Submittal Data Sheet 3MXS24RMVJU 3 Port, 2-Ton Outdoor Heat Pump 4•11m.lit 17 Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 6.17 Refrigerant Oil PVE (FVC50K) Cooling Heating Rate H 2,094 H 2,094 Airflow (cfm) M 2,094 M 1,981 1. 1,981 L 1,119 Sound Pressure Level (dBA) 52 / 54 Dimensions (H x W x D) (in) 28-15/16 x 34-1/4 x 12-5/8 Weight (Lbs) 137 Efficiency SEER EER HSPF COP Non -Ducted 18 12.7 12.5 3.53 Ducted 14 9.7 8,2 3.44 Mixed 15.95 11.2 10.35 3.49 Performance Cooling (Btu/fir) Rated 24,000 Operating Range 14°F - 115°F Rated Cooling Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB Heating (Btu/hr) Rated 24,000 Operating Range 5°F - 60°F Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB Electrical 208/60/1 230/60/1 System MCA 21.9 21.9 System MFA 25 25 Compressor RLA 15.5 15.5 Outdoor fan motor FLA .25 25 Outdoor fan motor W 73 73 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) X x 3 Gas (in) 3/8 x 1, 1/2x 2 Drain (in) 11/16 Max. System Piping Length (ft) 230 Max. Interunit Piping Length (ft) 82 Max. Height Difference - IDU to ODU (ft) 49.25 Max Height Differentce - IDU to IDU 24.625 Chargeless (ft) 131.6 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 1 of 7 . 1/4 (7) HANDLE 9/16 (14 -3/16 (30) 4-HOLES FOR FOUNDATION BOLTS (M8 OR M10) LIQUID GAS 01/4 (06.4) $3/6 (09.5) 01/2 (012.7) 0 A 2.9116 (65 3-11116 (93 3.5&16 (84 SERVICE PO 341/4 (870) 23.5/8 (600) DRAIN OUTLET (109518 ($15.9) HOSE FOR CONNECTION WITN DRAIN JOINT 4•GROUND TERMINALS LIQUID STOP VALVE GAS STOP VALVE IN CASE OF REMOVING STOP VALVE 1-11/16 COVER AND TERMINAL STRIP COVER 43) •9/16 (90 BRAND NA PLAT MANUFACTURERS LABEL 4-15116 (125) 11/16 (18) <ROOM A> GAS PIPE (03/8 0.5) SINGLE UNION) LIQUID PIPE (g114 (q6.4) SINGLE UNION) <ROOM B> GAS PIPE (01/2 (012.7) SINGLE UNION) LIQUID PIPE (01/4 (06.4) SINGLE UNION) <ROOM C> vvuuwith muiavma. GAS PIPE (01/2 (012.7) SINGLE UNION) LIQUID PIPE (01/4(46.4) SINGLE UNION) WIRING INTERCONNECTING PIP 141/2 (360 a M 0 OUTDOOR AIRTHERMISTOR •1116 (78) MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE:LESS THAN 1200 3-15/16 (100) /m//!//m/V//////. 1.15/16 (50) Lc) a tn m C; 3D093198 a 0 L 3 44 N v L 44 ra c 0 E 0 C m O N N C O 0 N m x_' ,• u cv oaN N ,c 7 C 000;� O W 00 09' � t0 30m '^ `op al 4 ac LL 0 u OEE `1) t4 mL. • v 3 J a v u W u ✓ vao E o L• c zo C Y 4,C my DE > 0 O. E 0 C c 0 u 0 a 0 IL) �N+ 0 a N c 0 N w 0 N N 00 m a CO 0 m 'a) am 0 c 0 " v o: m E .o 1 • J J l Optional Accessories VDA IKIf Included Part Number Description DACA-WB-3 Mounting Bracket KEH063A4E Drain Pan Heater 2/3/4MXS & 2/3MXL KPW063A4 Air Adjustment Grille KKG063A42 Back protection wire net KKG063A43 Side protection wire net KPS063A41 Snow hood (intake side plate) KPS063A44 Snow hood (intake rear plate) KPS063A47 Snow hood (outlet) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 3 of 7 n 7 LJ j li u u L�1 3MXS24RMVJU Capacity Tables Non- Ducted, 60 Hz, 208-230V Cooling Capacity of each indoo unit Heatin/Capacity of each indoor unit Combination of indoor unit Each Capacity To Indoor Unit Capacity A room B room C room D room Rating (min ^ max) 07 7.60 - - 7.60 7,30" 8.40 8.80 - - - 8.80 8,70 - 9.70 09 9.80 - - - 9.80 7.40 -10.80 11.30 - - 11.30 10.00 - 12.50 12 13.00 - - - 13.00 7.50- 14.40 15.00 - - - 15.00 9.90 "' 16.70 15 16.30 - - 16.30 8.90 -18.00 18.80 - - - 18,80 9.40 " 20.80 18 19.50 -- - - 19.50 8.90 ^' 21.60 22.50 - - - 22.50 9.40'" 25.00 07+07 7.60 7,60 - - 15.20 8.90'" 16.80 8.75 8.75 - - 17.50 9.30 - 19.40 07+09 7.69 9.61 - - 17 30 8.90 ` 19.20 8.89 11.11 - - 20.00 9.20" 22.20 07+12 7.31 12.79 - - 20.10 9.00 - 22.80 8.25 14.45 - - 22.70 9.10- 26.60 07+15 6.31 15.79 - - 22.10 10.00"26.40 6.69 16.71 - - 23.40 8.70 " 31.30 07+18 6.00 18.00 - - 24.00 10.0. 10'- 300 6.00 18.00 - - 24.00 8.70'' 36.00 09+09 9.75 9.75 - - 19.50 9.00'- 21.60 li 25 11.25 - - 22.50 9.10- 25.00 09+12 8.92 12.48 - - 21.40 9.10"24.20 9.63 13.48 - - 23.10 9.00 "' 29.70 09+15 7.80 15'60 - - 23.40 10.10 "' 28.80 7.93 15.87 - - 23.80 9.70"34.40 09+18 7.06 16.94 - - 24.00 10.10 " 30.00 7.06 16.94 - - 24.00 8.60 - 36.00 12+12 11.70 11.70 - - 23.40 9.20 ^ 28.80 11.90 11.90 - - 23.80 9.00^`34.40 12+15 9.88 14.12 - - 24.00 10.20'-30.00 9.88 14.12 - - 24.00 8.60"36.00 12+18 8.84 15.16 - - 24.00 10.20 - 30.00 8.84 15.16 - - 24.00 8.60- 36.00 15+15 1200 12.40 - - 24.00 10.80"30.00 12.00 12,00 - - 24.00 8.40 - 36.00 15+18 10.91 13.09 - - 24.00 10.80' 30.00 10.91 13.09 - - 24.00 8.40 - 36.00 18+18 12.00 12.00 - - 24.00 10.90 12.00 12.00 - - 24.00 8.30 - 36.00 07+07+07 7.13 7.13 7.13 - 21.40 102 .00 ^` 25.0 7.70 7.70 7.70 - 23.10 8.60 "' 29.70 07+07+09 6.98 6.98 8.73 - 2270 10.10-27.60 7.26 7.26 9.08 - 23.60 8.60- 32.90 07+07+12 6.40 6.40 11.19 -- 24.00 10.10-30.00 6.40 6.40 11.20 °- 24.00 8.50 " 36.00 07+07+15 5.33 5.33 13.33 - 24.00 10.80"30.00 5.33 5.33 13.32 - 24.00 8.30 " 36.00 07+07+18 4.80 4.80 14.40 - 24.00 10.80 - 30.00 4.80 4.80 14.40 - 24.00 8.30- 36.00 07+09+09 6.86 8.57 8.57 - 24.00 10.10 ^' 30.00 6.85 8.57 8.57 - 24.00 8.50 "' 36.00 07+09+12 6.00 7.50 10.49 - 24.00 10.20 "' 30.00 6.00 7.50 10.50 - 24.00 8.50 - 36.00 07+09+15 5.05 6.32 12.63 - 24.00 10.90' 30.00 5.05 6.32 12.63 - 24.00 8.30- 36.00 07+09+18 4.57 5.71 13.71 - 24.00 10.90 ^' 30.00 4.57 5.71 13.71 - 24.00 8.30 - 36.00 1 _ Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) n Submittal Revision Date: May 2018 Page 4 of 7 7 fl Li Li Cooling Capacity of each indoor unit Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room 8 room C room D room Rating (min - max) 07+12+12 5.33 9.33 9.33 24.00 10.30-30.00 5.34 9.33 9.33 24.00 8.40-36.00 07+12+15 4.57 8.00 11.43 24.00 10.90- 30,00 4.57 8.00 11.42 24.00 8.30-36.00 07+12+18 4.17 7.30 12.52 24.00 10.90 - 30.00 4.17 7.30 12.52 24.00 8.30-36.00 07+15+15 4.01 10.00 10.00 24.00 11.20 -30.CO 3.99 10.00 10.00 - 24,00 8.20-36.00 09+09+09 8.00 8.00 8.00 - 24.00 10.20- 30.00 8.00 8.00 8.00 - 24.00 8.50 - 36.00 09+09+12 7.06 7.06 9.89 24.00 10.30 30.00 7.06 7.06 9.88 - 24.00 8.40-36.00 09+09+1 5 6.00 6.00 12.00 - 24.00 10.90- 30.00 6.00 6.00 11.99 - 24.00 8.30-36.00 09+09+18 5.45 5.45 13.10 - 24.00 10.90 - 30.00 5.45 5.45 13.08 - 24.00 8.30 -36.00 09+12+1 2 6.32 8.84 8.84 24.00 10.30-30.00 6.31 8.84 8.84 - 24.00 8.40- 36.CD 09+12+15 5.45 7.64 10.91 - 24.00 10.90- 30.00 5.45 7.64 10.91 - 24.00 8.20-36.00 09+12+18 5.00 7.00 12.00 - 24.00 10.90-30.03 5.00 7.00 12.00 - 24.00 8.20 - 36.00 09+15+1 5 4.80 9.60 9.60 - 24.00 11.20 -30.00 4.80 9.60 9.60 - 24.00 8.20 - 36.00 12+12+12 8.00 8.00 8.00 - 24.00 10.40 - 30.00 8.00 8.00 8.00 24.00 8.40- 36.00 12+12+15 7.00 7.00 10.01 - 24.00 11.03- 30.00 7.00 7.00 10.00 - 24.00 8.20-36.00 n li Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) ri Submittal Revision Date: May 2018 Page 5 of 7 n n L_s u u u n 3MXS24RMVJU Capacity Tables Ducted, 60 Hz, 208-230V Cooling Capacity of each indoor unit Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room B room C room D room Rating (min - max) 7 7.1 - - - 7.1 7.30-7.10 8.3 - - - 8.3 9.00 - 9.70 09 9.1 - - - 9.1 7.30 - 9.60 10.7 - - - 10.7 10.40-12.50 7.30-12.10 12 12.1 - - - 12.1 14.3 - - - 14.3 10.40 - 16.70 15 14.8 -- - - 14.8 8.10 - 15.40 16.6 - - - 16.6 10.10 - 20.80 18 17.6 - - - 17,6 8.10 - 18.80 18.9 - - - 18.9 10.10-25.00 07+07 6.95 6.95 - - 13.9 8.80 - 14.30 7.9 7.9 - - 15.8 9.60-59.40 07+09 7.02 8.78 - - 15.8 8.80 - 16.60 7.73 9.67 - - 17.4 9.60 - 22.20 07+12 6.73 11.77 - - 18.5 8.80 - 19.90 7.13 17.47 - - 19.6 9.60 - 25,90 07+15 6.09 15.21 - - 21.3 9.40 - 23.30 6.23 15.57 - - 21.8 9.40 - 28,40 07+18 6 18 - - 24 9.40 - 26.60 6 17 99 - - 74 9.40 - 31.00 09+09 8.8 8.8 - - 17.6 8.80 - 18.80 11.05 11.05 - - 22.1 9.60 - 25.00 09+12 8.45 11.84 - - 20.3 8.80 - 22.10 8.79 123 - - 21.1 9.60 - 27.60 09+15 7.7 15.4 - - 23.1 9.40 - 25.50 7.77 15.53 - - 23.3 9.40 - 30.10 09+18 7.06 16.94 - - 24 9.40 - 27.00 7.06 16.94 - - 24 9.40 - 32.00 12+12 11.55 11.55 - - 2311 8.80 - 25.50 11.65 11.65 - - 23.3 9.60 - 30.10 12+15 9.88 14.12 - - 24 9.40 - 27.00 9.88 14.12 - - 24 9.40 - 32.00 12+18 8.84 15.16 - - 24 9.40 - 27.00 8.84 15.16 , - - 24 9.40 - 32.00 15+15 12 12 - - 24 9.90 - 27.00 12 12 - - 24 9.10 - 32.00 15+18 10.91 13.09 - - 24 9.90 - 27.00 10.91 13.09 - - 24 9 10 - 32.00 18+18 12 12 - - 24 9.90 - 27.00 12 12 - - 24 9.10 - 32.00 07+07+07 6.77 6.77 6.77 - 20.3 9.90 - 22.10 7.03 7.03 7.03 - 21.1 9.00 - 27.60 07+07+09 6.83 6.83 8.54 - 22.2 9.90 - 24.40 6.92 6.92 8.65 - 22.5 9.00 - 29.30 07+07+12 6.4 6.4 11 19 - 24 9.90 - 26.60 6.4 6.4 11.19 - 24 9.00 - 31.10 07+07+15 5.33 5.33 13.33 - 24 10.40 - 26.70 5.33 5.33 13.32 - 24 8.80 - 31.40 07+07+18 4.8 4.8 14.4 - 24 10.40 - 26.90 4.8 4.8 14.4 - 24 8.80 - 31.60 07+09+09 6.86 8.57 8.57 - 24 9.90 - 26.60 6.86 8.57 8.57 - 24 9.00 - 31.00 07+09+12 6 7.5 10.5 - 24 9.90 - 26.70 6 7.5 10.5 - 24 9.00 - 31.30 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) -i Submittal Revision Date: May 2018 Page 6 of 7 LJ 1 0 LJ LJ n 3MXS24RMVJU Capacity Tables VFD.n11E= CoolingCapacityofeach indoor unit Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Ca iacity A room B room C room D room Rating (min - max) 07+09+15 5.05 6.32 12.63 - 24 10.40 - 26.80 5.05 6.32 12.63 - 24 8.80 - 31.50 07+09+18 4.57 5.71 13.71 - 24 10.40 - 26.90 4.57 5.71 13.7 - 24 8.80 - 31.80 07+12+12 5.33 9.33 9.33 - 24 9.90 - 26.80 5.32 9.33 9.33 - 24 9.00 - 31.50 07+12+15 4.57 8 11.43 - 24 10.40 - 26.90 4.57 8 11.43 - 24 8.80 - 31.80 07+12+18 4.17 7.3 12.53 - 24 10.40 - 27.00 4.17 7.3 12.51 - 24 8.80 - 32.10 07+15+15 4.01 10 10 - 24 10.70 - 27.00 4 10 10 - 24 8.60 - 32.10 09+09+09 8 8 8 - 24 9.90 - 27.00 8 8 8 24 9.00 - 32.00 09+09+12 7.06 7.06 9.88 24 9.90 - 27.00 7.06 7.06 9.87 24 9.00 - 32.00 09+09+15 6 6 12 24 10.40 - 27.00 6 6 12 - 24 8.80 - 32.00 09+09+18 5.45 5.45 13.1 - 24 10.40 - 27.00 5.45 5.45 13.09 - 24 8.80 - 32.00 09+12+12 6.32 8.84 8.84 - 24 9.90 - 27.00 6.33 8.84 8.84 - 24 9.00 - 32.00 09+12+15 5.45 7.64 10.91 - 24.00 10.40 - 27.00 5.45 7.64 10.91 - 24 8.80 - 32.00 09+12+18 5.00 7.00 12.00 - 24.00 10.40 - 27.00 5 7 12 - 24 8.80 - 32.30 09+15+15 4.80 9.60 9.60 - 24.00 10.70 - 27.00 4.8 9.6 9.6 - 24 8.60 - 32.30 12+12+12 8.00 8.00 8.00 - 24.00 9.90 - 27.00 8 8 8 - 24 9.00 - 32.00 12+12+15 7.00 7.00 10.00 - 24.00 10.40 " 27.00 7 7 10 24 8.80 - 32.30 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Pagel of 7 r • 1 n LJ . _) .. A Job Name: Mutual Materials T.I. Tag# OHP-1B & 1C DAIKIN Submittal Data Sheet 4MXS36RMVJU 4 Port, 3-Ton Outdoor Heat Pump r7 pArrs wJ 'J FfE WA r Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 6.17 Refrigerant Oil PVE (FVC50K) Cooling Heating Airflow Rate H 2,613 H 2,351 (cfm) M 2,440 M 2,210 L 1,727 L 1,119 Sound Pressure Level (dBA) 54 / 56 Dimensions (H x W x D) (in) 28-15/16 x 34-1/4 x 12-5/8 Weight (Lbs) 139 Efficiency SEER EER HSPF COP Non -Ducted 17.7 9,2 12.2 3.89 Ducted 14 7.9 8.2 4.27 Mixed 15.85 8.55 10.2 4.08 Performance Cooling (Btu/hr) Rated 36,000 Operating Range 14°F —115°F Rated Cooling Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB Heating (Btu/hr) Rated 36,000 Operating Range 5°F — 60°F Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB Electrical 208/60/1 230/60/1 System MCA 23.9 23.9 System MFA 25 25 Compressor RLA 17.5 17.5 Outdoor fan motor FLA .42 .42 Outdoor fan motor W 122 122 MFA: Max. fuse amps MCA: RLA: Rated load amps (A) n, circuit amps (A) FLA: Full load amps (A) W: Fan motor rated output (W) Piping Liquid (in) '/, x 4 Gas (in) 3/8 x 1, '/: x 2, 5/8 x 1 Drain (in) 11/16 Max. System Piping Length (ft) 230 Max. Interunit Piping Length (ft) 82 Max. Height Difference — IDU to ODU (ft) 49.25 Max. Height Difference — IDU to IDU (ft) 24.625 Chargeless (ft) 131.6 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without Incurring any obligations) Submittal Revision Date: May 2018 Page 1 of 9 HANDLE 9/16 (14) 34.1/4 (870) 1/4 (7) \12.5/8 (320) 1.3/16 (30) m 4-HOLES FOR FOUNDATION BOLTS 5)16 OR 3/8 (M8 OR M10) 3.9/16 (90) BRANONAMEP 23-5/8 (600) 4.15/16 (125) DRAIN ggO��UTLETT \(IWITH 8 (01 .9) HOSE FOR CONNECTION 'A. 'El DRAIN OUTLET WHEN CONDUCTING CONCENTRATED DRAIN PIPING WORK, ATTACH THE SUPPLIED DRAIN CAPS. ROUND T1RMINALS 0 SERVICE PORT i , LIQUID STOP VALVE (GAS STOP VALVE IN CASE OF REMOVING STOP VALVE 1.11116 (43) COVER AND TERMINAL STRIP COVER 11116 (18) ELECTRIC WIRE INTAKE INTERCONNECTING PIPING TOP VALVE COVER 7/16(11) Z" (INSTALLATION LEG PITCH) 14.1/2 (368) ROOM A» GAS PIPE (06109.5) SINGLE UNION) LIQUID PIPE (0114 (08.4) SINGLE UNION) GASOPIPE 6» (0112 (012.7) SINGLE UNION) LIQUID PIPE (0V4 (A.4) SINGLE UNION) «ROOM C» GAS PIPE (01.12 a12.T SINGLE UNION) IOWPIPE (0114105,4) SINGLE UNION) «ROOM D» AS PIPE (413 015.91 SINGLE UNION) LIQUID PIPE 101i4 064 SINGLE UNION) OUTDOOR AIR THERMISTOR 3-1/16 (78) MINIMUM SPACE FOR AIR PASSAGE EIGHT ON AIR OUTLET SIDE = LESS THAN 47.114 (1200) UNIT: inch (mm • m � w 0 0 L N 000 • r0 ✓ 0. ,v L c c 0 E 0 c c m NC O 0 Xw -u ,u Cd O a., H , c • c 0 O 04 '« I 'H al O 4 40 O A �1j 0 0 t0• ro ,n 4 toaG a2. 'I` E c c • o� 0 NL4 4 Evc O � • C t0 ZO c� Y C � • E v 0 n E 0 0 00 u O 0 3D093199A 3 • F+ N C • C t 0 • " 0 0 d cc " m C �+ E ro C1 f 7 L_J (-1 r—, LJ •I L./ r- J L L-1 A Optional Accessories r/DAIKIN1 Included Part Number Description DACA-WB-3 Mounting Bracket KEH063A4E Drain Pan Heater 2/3/4MXS & 2/3MXL KPW063A4 Air Adjustment Grille KKG063A42 Back protection wire net KKG063A43 Side protection wire net KPS063A41 Snow hood (intake side plate) KPS063A44 Snow hood (intake rear plate) KPS063A47 Snow hood (outlet) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 3 of 9 n L 4MXS36RMVJU Capacity Tables VIY311E= u n t_i fl L.A n n n n Non- Ducted, 60 Hz, 208-230V Cooling Capacity of each indoor unit HeatinfriCapacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room B room C room D room Rating (min - max) 07 7.60 - 7.60 6.80- 8.40 8.80 - - 8.80 8.30- 9.70 09 9.80 - - - 9.80 6.90- 10.80 11.30 - - - 11.30 11.20 - 12.50 12 13.00 13.00 7 00 - 14 40 15.00 15.00 11.10 - 16.70 15 16.30 - - 16.30 8.20 - 18.00 18.80 - - 18.80 10.50- 20.80 18 19.50 - - 19.50 8.20- 21.60 22.50 - - 22.50 10.50- 25.03 24 26.26.00- - 26.00 8.60- 28.80 27.00 - 21.03 10.30- 34.40 07+07 7.60 7.60 - - 15,20 8.20- 16.80 8.75 8.75 - 17.50 10.40- 19.40 07+09 7.69 9.61 17.30 8.30-19.20 8 89 11.11 20 00 10 30- 22 20 07+12 7.49 13.11 - 20.60 8.30- 22.80 8,47 14.83 - - 23.30 10.20- 26.60 07+15 6.80 17.00 - - 23 80 9.30- 26.40 7 29 18.21 - - 25 50 9 80- 31 30 + 0718 6.70 20.10 - - 26.80 9.30 - 30.03 6.95 20.85 - - 27.80 9.7036.00 07+24 6.99 24.81 - 31.80 9.60- 34.40 7.10 25.20 32.30 9.60- 39.80 09+09 9.75 9.75 19.50 8.30- 21.60 11.25 11.25 - - 22.50 10.20- 25.00 09+12 9.50 13.30 - - 22.80 8.40 - 25.20 10.33 14.47 - - 24.80 10.10 - 29.70 09+15 8.67 17,33 - - 26.00 9.30 - 28.80 9.00 18.00 - - 27.00 9.70 - 34.40 09+18 8.38 20.12 - - 28,50 9.30 31.50 8.62 20.68 - - 29.30 9.70 - 37.30 09+24 8.72 24.78 - - 33,50 9.60 35.80 8.80 25.00 33.80 9.60- 41.10 12+12 13.00 13.00 26.00 8,50- 28.80 13.50 13-50 - 27.00 10.00- 34.40 12+15 11.74 16 76 - - 28.50 9.40-31.50 12.06 17.24 - - 29.30 9.60-37.30 12+18 11.42 19.58 - - 31.00 9.40 - 33.60 11.61 19,89 - - 31 50 9.60 - 39.20 12+24 11.89 24.11 - - 36.00 9.70 - 38.00 11.89 24.11 - - 36,00 9.50 - 43.00 15+15 15.50 1.5Q - 31,00 10,00 - 33.60 15.75 15.75 31,50 9.30 - 39,20 15+18 15.23 18.27 33.50 10.00 - 35.80 15.36 18.44 - - 33.80 9.30- 41.10 15+24 14.88 21.12 - 36.00 10.20- 38.00 14.88 21.12 - - 36.00 9.20- 43.00 18+18 18.00 18.00 - - 36,00 10.03-38.00 9.30 - 43.00 18.00 18.00 - - 36.00 18+24 16.49 19.51 - - 36.00 10.20 - 38.00 16.49 19.51 - - 36.00 9 20 - 43.00 + 2424 18.00 18.00 36.00 10.30 - 38.00 18.00 18.00 36.00 8.60-36 50 07+07+07 7.60 7.60 7.60 - 22,80 9.20 - 25.20 8.27 8.27 8.27 - 24.80 9.60- 29.70 07+07+09 7.66 7.66 9.58 - 24.90 9.30- 27.60 8.09 8.09 10.12 - 26.30 9.60-32.93 07+07+12 7.39 7.39 12.92 - 27.70 9.40- 30.70 7.60 7.60 13.30 - 28.50 9.50- 36.60 77 +15 0+0 6.71 6.71 16.78 - 30,20 10 00 - 32,90 6.84 6.84 17.10 - 30.80 9.20 - 38.50 07+07+18 6.54 6.54 19.62 32 70 10 00 - 35 10 6.60 6.60 19.80 33.00 9,20 -40.50 07+07+24 6.49 6.49 23.02 36.00 10.20- 38.00 6.49 6.49 23.03 - 36,00 9.20- 43.00 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 4 of 9 4MXS 6RMV U Capacity Tables n 7 LI 7 r- Li LJ Cooling Capacity of each indoor unit ... . Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room B room C room D room Rating (min - max) 07+09+09 7.66 9.57 9.57 - 26,80 9.40- 30.00 7,93 9.93 9.93 27.80 9.50- 36.00 07+09+12 7.33 9,16 12.81 - 29.30 9.40-32.20 7.50 9.38 13.13 - 30 CO 9 50- 37 90 07+09+15 6.69 8 37 16.74 - 31.80 10.00- 34.40 6.80 8.50 17.00 - 32.30 9.20- 39.80 07+09+18 6.53 8 17 19.60 34.30 1000-36 50 6.57 8.21 19.71 34.50 9.20 - 41,70 07+09+24 6.21 7.76 22.03 36.00 10.20 - 38.00 6.21 7.76 22.03 36,00 9.10 43.00 07+12+12 7.07 12.37 12.37 - 31.80 9.50-34.40 7.19 12.56 12.56 - 32.30 9.40- 39.80 07+12+15 6.53 11.43 16.33 - 34.30 10.00- 36.50 6.57 11.50 16.42 - 34.50 9.20- 41.70 07+12+18 6.26 10.96 18.78 - 36.00 10.10- 38.03 6.26 10.96 18.78 - 36.00 9.20 43.03 07+12+24 5.71 10 00 20.29 36.00 10 20 - 38 00 5.71 MOO 20.29 36.00 9.10 - 43.00 07+15+15 6.01 15.00 15.00 - 36.00 10.40 - 38.00 5.99 15.00 15.00 - 36.00 9.00- 43.00 07+15+18 5.54 13.85 16.61 - 36.00 10.40 - 38 00 5.54 13.85 16.62 - 36.00 9.00- 43.00 07+18+18 5,14 15.43 15.43 - 36.00 10,40 - 38.00 5.14 15.43 15.43 - 36,00 9.00- 43.00 9.50 9.50 9.50 28.50 9.40- 31.50 9.77 9.77 9.77 29.30 9.50- 37.30 09+09+12 9.12 9.12 12.77 31.00 9.50 - 33.60 9.26 9 26 12.97 - 31 50 9 40- 39 20 09+09+15 8.38 8.38 16.75 - 33.50 10.00 - 35.80 8.45 8.45 16.89 - 33.80 9.20- 41.10 09+09+18 8.18 8.18 19.65 - 36.00 10.10 - 38.00 8,18 8.18 19.63 - 36.00 9.20 - 43.00 09+09+24 7.44 7.44 21.13 36.00 10 20 - 38 00 7.44 7.44 21,11 36.00 9.10- 43.00 09+12+12 8.82 12.34 12.34 - 3 , 0 9.50-35.80 8.88 12.45 12.45 - 33.80 9.40- 41.10 09+12+15 8.18 11.45 16.36 - 36,00 10.10- 38.00 8.18 11.45 16.36 - 36,00 9.10 - 43.00 09+12+18 7.50 10.50 18.00 - 36.00 10.10 - 38.00 7,50 10.50 18.00 - 36.00 9,10 43.00 09+12+24 6.87 9.62 19.51 36.00 10.20 - 38.00 6.87 9.62 19.51 36.00 9 10- 43 00 09+15+15 7.20 14.40 4.40 - 36.00 10.40- 38.00 7.20 14.40 14.40 - 36.00 9.00 - 43.00 09+15+18 6.67 13.33 16.00 - 36.00 10.40- 38.00 6.67 13.33 16.00 - 36.00 9.00- 43.00 09+15+24 6,16 12.33 17.51 - 36.00 10.40- 38.00 6.16 12.33 17.51 - 36.00 9.00- 43.00 09+18+18 6.21 14.90 14.90 36.00 10.40- 38.00 6.22 14.90 14.90 36.00 9.00- 43.0D 12+12+12 12.00 12.00 12.00 - 36.00 9.60 - 38.00 12.00 12.00 12.00 - 36.00 9 30- 43 CO 12+12+15 10.50 10.50 15.01 - 36.00 10.10 - 38.00 10.50 10.50 15.00 - 36.00 9.10 - 43.00 12+12+18 9.69 9.69 16.62 - 36.00 10.10 - 38.00 9.69 9.69 16.62 - 36.00 9.10 - 43.00 12+12+24 8.94 8.94 18.13 - 36.00 10 10 - 38,00 8.94 8.94 18.13 36.00 9.00- 43.00 12+15+15 9.33 13,33 13.33 - 36.00 10.40- 38.00 9.33 13.33 13.33 - 36.00 9.00- 43.00 12+15+18 8.69 12.41 14.90 - 36.00 10.40-38.00 8.69 12.41 14.90 - 36.00 9.00- 43.00 12+18+18 8.13 13.94 13.94 - 36.00 10.40 - 38.00 8.13 13.94 13.94 - 36.00 9.00 - 43.00 L5+15+15 12.00 12.00 12.00 - 36.00 10.40 - 38.00 12.00 12.00 12,00 36 DO 9.00- 43,00 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 5 of 9 LJ 4MXS36RMVJU Capacity Tables Vm1\ IILL7h7 1 I v J j J 7 J 1 J J Cooling Capacity of each indoor unit Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room 8 room C room D room Rating (min - max) 15+15+18 11.25 11.25 13.50 - 36.00 10.40 " 38.00 11.25 11.25 13.50 - 36.00 9.00"43.00 07+07+07+07 7.33 7.33 7.33 7.33 29.30 10.00"32.20 7.50 7.50 7.50 7.50 30.00 9.20 "' 37.90 07+07+07+09 7.29 7.29 7.29 9.12 31.00 10.00"33.60 7.41 7.41 7.41 9.27 31.50 9.10 " 39.20 07+07+07+12 7.05 7.05 7.05 12.34 33.50 10.00"35.80 7.12 7.12 7.12 12.45 33,80 9.10"41.10 10.40"38.00 07+07+07+15 6.55 6.55 6.55 16.36 36.00 6.55 6.55 6.55 16.35 36.00 9.00"43.00 07+07+07+18 6.00 6.00 6.00 18.00 36.00 10.40"38.00 6.00 6.00 6.00 18.01 36.00 9.00"43.00 07+07+07+24 5.50 5.50 5.50 19.51 36.00 10.40"38.00 5.50 5.50 5.50 19.52 36.00 9.00"43 00 07+07+09+09 7,27 7.27 9.08 9.08 32.70 10.00 " 35.10 7.33 7.33 9.17 9.17 33.00 9.10"40.50 10.10"37.30 07+07+09+12 7.04 7.04 8.80 12.32 35.20 7.06 7.06 8.83 12.35 35.30 9.10"42.40 10.40"38.00 07+07+09+15 6.26 6.26 7.83 15.65 36.00 6.26 6.26 7.83 15.66 36.00 9.00"43.00 10.40"38,00 07+07+09+18 5.76 5.76 7.19 17.28 36.00 5.76 5,76 7.20 17.29 36.00 9.00"43.00 10.40"38.00 07+07+09+24 5.29 5.29 6.61 18.79 36.00 5.29 5.29 6.61 18.79 36.00 9.00"43.00 10.10 " 38.00 07+07+12+12 6.55 6.55 11.45 11.45 36.00 6.55 6.55 11.45 11.45 36.00 9.10"43.00 07+07+12+15 5.76 5.76 10.07 14.40 36.00 10.40"38.00 5.76 5.76 10.08 14.41 36.00 9.00 " 43.00 07+07+12+18 5.33 5,33 9.33 16.00 36.00 10.40"38.00 9.00"43.00 5.33 5.33 9.33 16.00 36,00 07+07+15+15 5.14 5.14 12.86 12.86 36.00 10.40"38.00 5.14 5.14 12.86 12.86 36.00 9.00 " 43.00 07+07+15+18 4.80 4.80 12.00 14.40 36.00 10.40"38.00 4.80 4.80 12.00 14.40 36.00 9.00"43.00 10.10' 36.50 07+09+09+09 7.23 9.03 9.03 9.03 34.30 7.27 9,08 9.08 9.08 34.50 9.10"41.70 10.10"38.00 07+09+09+12 6.87 8.57 8.57 12.00 36.00 6.86 8.57 8.57 12.00 36.00 9.10"43.00 10.40"38.00 07+09+09+15 6.00 7.50 7.50 15.00 36.00 6.00 7.50 7.50 15.00 36.00 9.00"43.00 07+09+09+18 5.54 6.92 6.92 16.62 36.00 10.40" 38.00 5.54 6.92 6.92 16.63 36 00 9.00" 43.00 07+09+12+12 6.26 7.83 10.97 10.96 36.00 10.10"38.00 9.00"43.00 10.40"38.00 6.26 7.83 10.96 10.96 36.00 07+09+12+15 5.54 6.92 9.69 13.85 36.00 5.54 6.92 9.69 13.85 36.00 9.00"43.00 07+09+12+18 5.14 6.43 9.00 15.43 36.00 10.40"38.00 5.14 6.43 9.00 15.43 36.00 9.00"43.00 10.40 " 38.00 07+09+15+15 4.97 6.21 12.42 12.41 36.00 4.97 6.21 12.42 12.41 36.00 9.00 " 43.00 07+12+12+12 5.75 10.08 10.08 10.08 36.00 10.20 " 38.00 5.77 10.08 10.08 10.08 36.00 9.00 " 43.00 07+12+12+15 5.14 9.00 9.00 12.86 36.00 10.40"38.00 9.00"43.00 5.14 9.00 9.00 12.86 36.00 09+09+09+09 9.00 9.00 9.00 9.00 36.00 10.10" 38.00 9.00 9.00 9.00 9.00 36.00 9,10"43.00 10.10 " 38.00 09+09+09+12 8.18 8.18 8.18 11.45 36.00 8.18 8.18 8.18 11.45 36.00 9.00"43.00 09+09+09+15 7.20 7.20 7.20 14.40 36.00 10.40"38.00 7.20 7.20 7.20 14.40 36.00 9.00"43.00 10.40"38.00 09+09+09+18 6.67 6.67 6.67 16.00 36.00 6.67 6.67 6.67 16.01 36.00 9.00"43.00 10.20"38.00 9.00"43.00 09+09+12+12 7.50 7.50 10.50 10.50 36.00 7.50 7.50 10.50 10.50 36.00 09+09+12+15 6.67 6.67 9.34 13.33 36.00 10.40"38.00 6.67 6.67 9.33 13.34 36.00 9.00"43.00 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 6 of 9 n, n LJ n u U �MXS36RMVJU Capacity Tables Cooling Capacity of each indoor unit Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room B room C room D room Rating (min "' max) 09+09+12+18 6.21 6.21 8.70 14.90 36.00 10.40 ^ 38.00 6.21 6.21 8.70 14.90 36.00 9.00 "' 43.00 09+09+15+15 6.00 6.00 12.00 12.00 36.00 10.40 - 38.00 6.00 6.00 12.00 12.00 36.00 9.00- 42.95 09+12+12+12 6.93 9.69 9.69 9.69 36.00 10.20 - 38.00 6.91 9.69 9.69 9.69 36.00 9.00 "' 43.00 09+12+12+15 6.21 8.69 8.69 12.41 36.00 10.40 - 38.00 6.21 8.69 8.69 12.41 36.00 9.00 " 43.00 12+12+12+12 9.00 9.00 9.00 9.00 36.00 10.20 - 38.00 9.00 9.00 9.00 9.00 36.00 9.00 - 43.00 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 7 of 9 li 4MXS36RMVJU Capacity Tables Vi-oDnurc= u Li u u L u Ducted, 60 Hz, 208-230V Cooling Capacity of each indoor unit Heating Capacity of each indoor unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room B room C room D room Rating (min - max) 9.40 - - - 9.40 9.40 6.70 `09 10.70 - - - 10.70 10.60 -12.50 12 12.50 - - - 12.50 6.70 -12.50 14.30 - - - 14.30 11.60-16.70 15 15.60 - - - 15.60 7.50 15.60 17.00 - - - 17.00 11.20" 20.80 18 18.80 - - - 18.80 7.50 -18.80 19.70 - - - 19.70 11.20 - 25.00 24 25.00 - - - 25.00 7.80" 25.00 25.00 - -- - 25.00 11.10 " 29.70 09+09 9.40 9.40 - - 18.80 8.10 -18.80 11,05 11.05 - - 22.10 10.80- 25.00 09+12 9.12 12.78 - - 21.90 8.10- 21,90 9 29 13.00 - - 22.30 10.80 - 27.30 09+15 8.33 16.67 - - 25.00 8.7 " 25.00 8.33 16.67 - - 25.00 10.50-30.80 09+18 7.79 18.71 - - 26.50 8.70 - 27.00 7.79 18.71 - - 26.50 10.50"32.00 09+24 7.68 21.82 - - 29.50 8.90 - 31.00 7.68 21.82 - - 29.50 10.40" 36.00 12+12 12.50 12.50 - - 25.00 8.10 ` 25.00 15.90 15.90 - - 31.80 10.80-31.80 12+15 10.91 15.59 - - 26.50 8.70- 27.00 10.91 15.59 - - 26.50 10.50 - 32.00 12+18 10.32 17.68 - - 28.00 8.70 "' 29.00 10.32 17.68 - - 28.00 10.50 - 34.00 12+24 10.24 20.76 - - 31.00 8.90 - 33.00 10.24 20.76 - - 31.00 10.40 "' 38.00 15+15 14.00 14.00 - - 28.00 9.20 - 29.00 14.00 14.00 - - 28.00 10.20 - 34.00 15+18 13.41 16.09 - - 29.50 9.20- 31.00 13.41 16.09 - - 29.50 10.20 - 36.00 15+24 12.93 18.37 - - 31.30 9.40 33.30 12.93 18.37 - - 31.30 10.10 - 38.00 18+18 15.50 15.50 - - 31.00 9.20 - 33.00 15.50 15.50 - - 31.00 10.20 - 38.00 18+24 14.52 17.18 - - 31.70 9.40 - 33.50 14.43 17.07 - - 31.50 10.10" 38.00 24+24 16.15 16.15 - - 32.30 9.50 - 34.00 16.00 16.00 - - 32.00 9.50 - 35.60 09+09+09 8.83 8.83 8.83 - 26.50 9.10 - 27.00 8.83 8.83 8.83 - 26.50 10.10 -32.00 09+09+12 8.24 8.24 11.53 - 28.00 9.10 - 29.00 8.24 8.24 11.52 - 28.00 10.10"34.00 09+09*15 7.38 7.38 14.75 - 29.50 9.60 -31.00 7.38 7.38 14,75 - 29.50 9.90-36.00 9.60 - 33.00 09+09+18 7.05 7.05 16.92 - 31.00 7.05 7.05 16.91 - 31.00 9.90 ` 38.00 09+09+24 6.55 6.55 18,61 - 31.70 9.70 ` 33.50 6.51 6.51 18.48 - 31.50 9.80 - 38.00 09+12+12 7.76 10.87 10.87 - 29.50 9.10 - 31.00 7 77 10.87 10.87 - 29.50 10,10 - 36.00 09+12+15 7.05 9.86 14,09 - 31.00 9,60 " 33,00 7.05 9.86 14.09 - 31.00 9.90- 38.00 09+12+18 6.52 9.13 15.65 - 31.30 9.60 - 33.30 6.52 9,13 15.65 - 31.30 9.90-38,00 09+12+24 6.11 8.55 17.34 - 32.00 9.70"33.80 6.07 8.50 17.24 - 31.80 9.80 - 38.00 09+15+15 6.26 12.52 12.52 - 31.30 9.90 - 33.30 6,26 12.52 12.52 - 31.30 9.70"38.00 09+15+18 5.87 11.74 14.09 - 31.70 9.90 - 33.50 5.83 11.67 14.00 - 31.50 9.70- 38.00 09+15+24 5.53 11.06 15.71 - 32.30 10.00 - 34.00 5.48 10.96 15.56 - 32.00 9.60"38.00 09+18+18 5.52 13.24 13.24 - 32.00 9.90' 33.80 5.48 13.16 13.16 - 31.80 9.70- 38.00 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) rl Submittal Revision Date: May 2018 I Page 8 of 9 4MXS36RMVJU Capacity Tables n 7 LJ 7 Cooling Capacity of each indoor unit Heating Capacity of each indoo unit Combination of indoor unit Each Capacity Total Indoor Unit Capacity A room B room C room D room Rating (min - max) 12+12+12 10.33 10.33 10.33 - 31.00 9.10-33.00 10.33 10.33 10.33 31,00 10.10- 38.00 12+12+15 9.13 9.13 13.04 31.30 9.60- 33.30 9.13 9.13 13.04 31 30 9.90- 38.00 12+12+18 8.53 8.53 14.62 31.70 9.60-33.50 8.48 8.48 14.55 9.90 - 38.(X) 12+12+24 8.02 $.02 16.25 9.60 - 34,00 7.94 7.94 16.10 32.00 9 60- 38 00 12+15+15 8,21 11.74 11.74 31.70 9,90- 33.50 8.17 11.67 11.67 31.50 9.70-38.00 12+15+18 7.72 11.03 13.24 32.00 9 90-33 80 7.68 10 97 13.16 31.80 9.70-38.00 990-3400 12+18+18 7.28 12.50 12.50 32.30 7.22 12.39 12.39 - 32.00 9.70- 38.00 15+15+15 10.67 10.67 10.67 - 32.00 10.10-33.80 10.60 10,60 10.60 - 31.80 9.50-38.00 15+15+18 10.09 10.09 12.10 32.30 10.10- 34.00 10.00 10.00 11.99 - 32.00 9.50- 38.00 09+09+09+09 7.75 7.75 7.75 7.75 31.00 9 90- 32 98 7.75 7.75 7.75 7.75 31.00 9.60- 38.00 09+09+09+12 7.11 7.11 7.11 9.96 31.30 9.90 - 33.30 7.11 7.11 7.11 9.97 31.30 9 60- 38 00 09+09+09+15 6.34 6.34 6.34 12.68 31.70 10.10 - 33.50 6.30 6.30 6.30 12.60 31.50 9.40 38.00 09+09+09+18 5.93 5.93 5.93 14.22 32.00 10.10-33.80 5.89 5.89 5.89 14.12 31.80 9.40- 38.00 09+09+12+12 6.60 6.60 9.25 9.25 31.70 9.90-33,50 6.56 6.56 9i.9 9.19 31.50 9.60-38.00 09+09+12+15 5.93 5.93 8.29 11.85 32.00 10.10-33.80 5.89 5.89 8.24 11.78 31.80 9.40- 38.00 09+09+12+18 5.57 5.57 7.79 13.37 32.30 10 10 - 34 00 5.52 5.52 7.71 13.24 32.00 9.40- 38.00 09+09+15+15 5.38 5.38 10.77 10.77 32.30 10 30 - 34.00 5.33 5 33 10.67 10.67 32.00 930-3800 09+12+12+12 6.16 8.62 8.62 8.62 32.00 9.90 - 33.80 6.12 8.56 8.56 8.56 31.80 9.60-38.00 09+12+12+15 5.57 7.80 7.80 11.14 32.30 10.10- 34.00 5.52 7,72 7.72 11.03 32.00 9.40- 38.00 12+12+12+12 8.08 8.08 8.08 8.08 32.30 9.90-34.00 8.00 8.00 8.00 8.00 32.00 9.60-38,00 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2018 Page 9 of 9 2. Daikin Temperature Controllers Names of Parts Remote Controller Signal transmitter 1 Receiver • To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate. • Do not drop the remote controller. Do not get it wet. • The maximum distance for communication is approximately 23ft (7m). FAN setting button • Selects the airflow rate setting. POWERFUL button • POWERFUL operation. Page 1 FDA/KIN a jiVr Al O + 121Y e7o•44 do OM MO? oFF�]a8:8s SATSUN 0 0®NOO.008 FAN r UOWOFF POWERFUL L.J TEMP'rlt Display (LCD) • Displays the current settings. (In this ilustration, each section is shown with all its displays on for the purpose of explanation.) 6 TEMPERATURE adjustment buttons • Changes the temperature setting. ON/OFF button • Press this button once to start operation. Press once again to stop it. ► Page 1 <ARC452A21> Front cover • Open the front cover. Page 8 7 • Open the front cover MODE selector button • Selects the operation mode. (AUTO/DRY/COOUHEAT/ FAN) =n QUIET button • OUTDOOR UNIT QUIET operation. CUM WEEKLY OFFTI ER button Pa e 20 TIMER CANCEL button • Cancels the timer setting. 1wPage 20 21 • It cannot be used for the WEEKLY TIMER operation. SELECT button • Changes the ON/OFF TIMER and WEEKLY TIMER settings. I.Page 20 21 22 A SEI.ECT V WY_ ECONO button • ECONO operation. I.Page 19 SWING button • Adjusting the airflow direction. COMFORT/SENSOR button • COMFORT AIRFLOW and INTELLIGENT EYE operation. WEEKLY COPY BACK NEXT :WEEKLY button : PROGRAM button : COPY button : BACK button : NEXT button WEEKLY TIMER operation. ON T on Page 22 P. _c 21 CLOCK button MEE 8 3. Exhaust Fans: EF-1 thru EF-5 ^ EF 1 thru EF 4 �.N uTone . " " ^^ I r L_^ ^' l .' I ., SPECIFICATION SHEET MODELS AEN50, AEN80, AEN110 INVENTTm SERIES FANS DESCRIPTION BLOWER: ° P1ugin'permanently lubricated motor - engineered for continuous operation ° Dynamically balanced centrifugal blower wheel for quiet, efficient performance " Low RPM for quiet operation HOUSING: ° Rugged, 2Ggauge, galvanized steel construction ° Polymeric, 4''duct connector with tapered sleeve and no metallic clatter °5-]/4"height allows for 2^xO^ceiling installations ° Sturdy, easy, four -point mounting directly Vojoist ° Can bomounted inceilings upoo3n2pitch GRILLE: ° Polymeric construction ° Innovative design ' the result ofextensive research with designers and consumers CONTROLS (Purchase sepmmte|y): °Refer uuNuTbne'ocatalog for ocomplete line of accessories ozeffectively adapt these fans onyour construction requirements. Ul.Listed for use over bathtubs and showers when connected toaGFO|protected branch circuit (ceiling mount only). U.L.Listed for use in insulated ceilings (TYPE iC.) 3-YearWarranty 'AEN8O.AEN11O 1'YbarWarranty 'AEN5O TYPICAL SPECIFICATION Fan shall beNuloneModel AEN5O.(AEN8O).(AEN11O). Fan shall have corrosion resistant galvanized steel housing with four -point mounting capability. |tshall beducted toa roof orwall cap using 4'round ductwork. Blower assembly shall beremovable, have acentrifugal- type b|mwerwheo|ondopermonondy|ubrioatedmotor designed for continuous operation. Non-metallic damper/duct connector shall baincluded. Air delivery shall bonnless than the airflow values and nogreater than the sound level values listed inthe HV| Performance Specifications provided inthis specification (see following chort).All air and sound ratings shall be certified byHVi Ceiling Ventilator shall beUl.Listed for use ininsulated ceilings (Type iC.)and for use over bathtubs and showers when connected to a GFC1 protected branch circuit. us Model AEN80 2100 1111� ���������� CERTIFIED � Bmen4JuTbneLLC Hartford, Wisconsin vmwwnutone.00m 888'336'3948 Models ENERGYSTAR REFERENCE REMARKS Project Location Architect Engineer Contractor Submitted by Date 51H 39045297C L.J PERFORMANCE RATINGS INVENT M SERIES FANS ` HVI PERFORMANCE r l 1 r-1 . _1 Model AEN50 AEN80 AEN110 0.1 Ps - Static Pressure (in H2O) Airflow (CFM) 50 80 110 2100 • HUI CERTIFIED Sound (Sones) 0.5 0.8 1.3 Power (Watts) 20.0 26.9 28.0 Efficacy (CFM / W) 3.55 2.97 3.93 0.25 Ps Airflow (CFM 37 60 92 HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off -the -shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly -perceived loudness, based on laboratory measurements. ELECTRICAL & WEIGHT Model AEN50 AEN80 AEN110 Volts 120 120 120 us Model AEN80 v Hz 60 60 60 Amps 0.2 0.3 0.3 Models AEN50, AEN110 NuTone Shipping Weight 10.0 10.0 10.0 ENERGY STAR AIR FLOW PERFORMANCE 0.6 0.5 t7 0.4 0.1 0.0 0 0.5 0.2 0.0 0.7 t; 0.5 o m 0.0 Model AEN50 NN\ 10 20 30 40 Air Flow (CFM - Cubic Feet per Minute) Model AEN80 0 10 20 30 40 50 60 70 Air Flow (CFM - Cubic Feet per Minute) 0 10 20 Broan-NuTone LLC Hartford, Wisconsin Model AEN110 30 40 50 60 70 80 90 Air Flow (CFM - Cubic Feet per Minute) www.nutone.com 888-336-3948 50 80 100 110 60 90 120 EF-5 LJ r- 4 1 LJ r L r fl L„J LJ BRikaAN' SPECIFICATION SHEET MODELS 508, 509 & 509S WALL FANS Efficient ventilation for a variety of applications. FEATURES GRILLE: • Contemporary styled grille complements modern decor • White polymeric grille can be painted to match any decor • Aluminum filter available — purchase separately MOTOR: • Permanently lubricated, thermally protected, plug-in motor • Motor assembly offers fast, easy "twist -lock" installation • Specially designed polymeric fan blade HOUSING: • Housing adjusts to fit walls from 41/2" to 91/2" thick • Rugged steel housing with modern profile on outer weather hood • Long-lasting electrically -bonded epoxy coating can be painted to match outdoor styling • Built-in backdraft damper • Built-in rotary switch on Model 509S — no wall switch to wire SPECIFICATIONS TYPICAL SPECIFICATION Ventilator shall be Broan Model 508 (Model 509) (Model 509S). Ventilator shall duct directly through an outside wall from 41/2" to 91/2" thick. Models 508 & 509 shall be controlled with a separate on -off switch or speed control. Model 509S shall be controlled with a built-in on -off switch. Ventilator shall be steel housing finished with electrically - bonded epoxy paint. Grille to be white polymeric. Motor assembly shall be removable and permanently lubricated. Air delivery shall be no less than 270 CFM and sound levels no greater than 7.0 Sones (Model 508), 180 CFM and 7.5 Sones (Models 509, 509S). All air and sound ratings shall be certified by HVI. Units shall be U.L. listed. MODEL VOLTS AMPS RPM SONES CFM DUCT 508 120 1.7 1625 7.0 270 10" Rd. 509 120 1.8 1925 7.5 180 8" Rd. 509S 120 1.8 1925 6.5 180 8" Rd. 2100 HVI CERTIFIED HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off -the -shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in AMCAs state-of-the-art test laboratory. Sones area measure of humanly -perceived loudness, based on laboratory measurements. MODEL 508 HOUSING MODELS 509 & 509S, HOUSING Broan Hartford, Wisconsin 53027 (1-800-637-1453) MODELS 509 & 509S GRILLE IV' MODEL 508 GRILLE OISVI REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 81J 99041068N 4. King Electric Wall Heaters: EWH-1 thru EWH-4 r r I. , r L. 1 f—, r� 14. , r� 1 , LJ r1 L_ J t. r r, PIC-A-WATT® - THE ORIGINAL FAN FORCED - BEST EWH-1 thru EWH-4 ENERGY EFFICIENCY SEE PAGE 110 o Smart Limit Protection® o Pic -A -Watt® Element • C-Frame Motor o Squirrel Cage Blower o Quiet Running • Multiple Wattage Element • 20 Gauge Powder Coated Grill with contemporary die formed round corners. • Standard Color - Bright White • Bi-Metallic Limit • Safety thermal cutout trips and turns off heater, • Optional 1-Pole or 2-Pole unit mount thermostat 45°-80° • Optional surface wall box • Optional Color - Almond • Optional ULTRA Custom Bar Grill • Available in Stainless Steel Refer to Index PICA -Watt ENGINEERING SPECIFICATIONS: MINtriiimmommumw The original multi -watt steel fin heater. This is a unique King de- sign that allows you to change the wattage of the heater by simply disconnecting a color coded ter- minal. But the best feature of this unique heater is how quiet it is. The high mass steel element transfers heat quietly and effi- ciently. The sleek appearance gives the desired look of a regis- ter grill used in central forced air systems. This is our most popular heater for a single family residence or upscale condominium. The ele- ment has a five year warranty and 12 year history of reliability. For www.king-electric.com PAW SERIES best results use with an electronic line voltage wall thermostat. NOTE: Heaters cannot be installed vertically. Contractor shall supply and install, PAW -series wall -mounted forced - air electric heaters, manufactured by King Electrical Mfg. Company, of the wattage and voltage as indicated on the plans. Ratings: Heaters shall be available in wattages of 250 to 2,250 at 120, 208, 240, or 277 volts. Blower and Motor: A tangential cylindrical blower, delivering 65 CFM, shall be driven by a shaded pole, permanently lubricated, C-frame type motor with impedance protection and sealed bear- ings. Motors shall be the same voltage as the heater. Elements: Elements assemblies shall be non -glowing design. El- ement assemblies shall consisting of three steel sheathed heat- ing tubes in a fumace brazed, plate finned, block design. Each sheathed tube shall contain coiled Ni-Chrome wire, embedded in an insulator of magnesium oxide. The element assembly shall provide a minimum of seven (7) possible wattage configurations available for selection during field installation. The use of exter- nal resistors, diodes, or other weak links to obtain multiple watt- ages will not be acceptable. Thermal Overload: Heaters shall be equipped with thermal over- load protection, which disconnects elements in the event normal operating temperatures are exceeded. The thermal overload pro- tection device shall automatically reset when normal operating temperatures are reached or manually reset by the thermostat. Wall Can: The wall can shall be 20 gauge electro-galvanized steel and shall contain a minimum of three (3) knockouts through which power leads are brought. The wall can shall have a depth gauge indicator, and a factory installed, insulated and stranded copper grounding wire. Minimum Clearance to Floors and Sidewalls. Zero clearance to combustibles. Grill: The grill shall be louvered, one piece design with rounded edges on all four sides, with rounded comers to prevent snags from contact with other materials. The grill shall be epoxy powder coated in white or almond. Approval: Heaters shall be listed and approved by Underwriters' Laboratories or equal, 8 . _ ® KING ELECTRICAL MFG. CO. • 9131 10TH AVENUE SOUTH • SEATTLE, WA 98108 • TEL: 206.762.0400 • FAX: 206.763.7738 r I r 13 king www.king-electrictom r Standard Color: Bright White 1 ' I L J J ULTRA Grill (No Built -In Thermostat) Potent Pending DIMENSIONS 1214" Wall Can 1Y: Top Bottom Recessed Wall Can 13W Grill 6- Front Left Side 7W 1•1)1)1/ n 11-41 viaroo: atigt, ,Irl, issIrm; ;1;01 ig itojo)gt pd,I41) ,I, itliT it% ;jtitly ripIVIM ', l'ike' A 311IIII ft i1.77::,; I :1 P4A7) fn. 250'5007501000.1250.1500 ' PAW1215 16303 500•750•1000 1250•1500•1750•225C PAW2022 00512 PAW2422 16300 1000.2000 PAW2720 16302 1.1)?IiIRS) -U For ULTRA Custom Bar Grill - Not available with built-in thermostat. 12 -I For Interior and Grill only (No Wall Can) 7.5 -H For Interior only (No Can or Grill) 6 -OGA For 13"H x 13%"IN Retrofit Grill 11 -0GB For 81/2"H x 17"W Retrofit Grill 11 PT-1 - Stat Kit SPST PT-2 - Stat Kit DPST :AOC NINS:41117/.11,11: t WV' 1 t, okei zit. nifAIN PAWF Recess Can W/Flange (Remodel) 16319 3.5 PAWIC Recess Wall Can 00515 3.5 PAWS PIC-A-WATT Surface Can - White 13%"L x 41/4"W x 7%"H 16305 4 PAWS -A PIC-A-WATT Surface Can - Almond 13WL x 4%"W x 7%"H 19298 4 PAWG Grill - White 16304 2 PAWG-A Grill - Almond 16335 2 PAW -GUARD Safety Guard for PAW 16550 3.5 PAWOG-A 13"H x 13"W Retrofit Grill 00555 PAWOG-B 8%"H x 17"W Retrofit Grill 00560 ULTRA-W ULTRA Grill - White 18740 4 ULTRA -A ULTRA Grill - Almond 18745 4 PT-1 SP STAT KIT 16306 .5 PT-2 DP STAT KIT 16307 .5 PAW -DISPLAY Counter Top Display 16308 20 Standard left hand feed for power supply. PAWF - Flanged Wall Can for Remodel Work or Wood Walls. It KING ELECTRICAL MFG. CO. • 9131 I0TH AVENUE SOUTH • SEATTLE, WA 98108 - TEL: 206.762.0400 • FAX: 206.763.7738 9 PERMIT COM COPY PLAN REVIEW/ROIJTING SLIP PERMIT NUMBER: M19-0033 PROJECT NAME: MUTUAL MATERIALS SITE ADDRESS: 4302 S 104 PL X Original Plan Submittal Response to Correction Letter # DATE: 03/05/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: k\‘') uilding Division Public Works RR ftl\A 1M ire Prevention Planning Division Structural Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/07/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 04/04/19 Approved with Conditions Denied (ie: Zoning Issues REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Ej Fire LJ Ping LJ PW [i] Staff Initials: 12/18/2013 Home Espanol Contact Search L&I Safety & Health Claims & Insurance C1 Washington State Department of Labor & Industries A-Z Index Help My MI Workplace Rights Trades & Licensing UNIVERSAL REFRIGERATION INC Owner or tradesperson Principals GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT GATES, CHRIS A, AGENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. 600 599 723 PO BOX 614 AUBURN, WA 98071-0614 253-939-5501 KING County Business type Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties COMMERCIALJINDUSTRIAL/REFRIG License no. UNIVERI159RF Effective — expiration 12/06/1985— 04/01/2020 Bond AMERICAN STATES INS CO Bond account no. EX903622 $6,000.00 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co $1,000,000.00 Policy no. Help us improve CO-3N976157 Received by L&I Effective date 03/29/2019 04/01/2019 Expiration date 04/01/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 469,068-01 Doing business as UNIVERSAL REFRIGERATION INC Estimated workers reported Quarter 4 of Year 2018 "51 to 75 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/09/2014 Inspection no. 316993518 Location 6742 185th Ave NE Redmond, WA 98052 Violations Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve HVAC ABBREVIATIONS AFF ABOVE FINISHED FLOOR BDD BACKDRAFT DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CU CONDENSING UNIT DB DECIBEL DH DUCT HEATER DOAS DEDICATED OUTSIDE AIR SYSTEM DN DOWN EC EER EF EG ERV ESP EXH FCU FD FPM FSD GA GF GRD HP ID IHP IRH KW MBH MCD NC NIC NTS OBD OC OD OHP OSA OSCI POC RA RAG RPM RTU SA SG SP SSG TBD TG TYP UH VFD VTR VVT EVAPORATOR COIL ENERGY EFFICIENCY RATIO EXHAUST FAN EXHAUST GRILLE ENERGY RECOVERY VENTILATOR EXTERNAL STATIC PRESSURE EXHAUST FAN COIL UNIT FIRE DAMPER, FLOOR DRAIN FEET PER MINUTE FIRE AND SMOKE DAMPER GAUGE GAS FURNACE GRILLE, REGISTER, DIFFUSER HORSEPOWER, HEAT PUMP INSIDE DIMENSION INDOOR (SECTION) HEAT PUMP INFRARED HEATER KILOWATT THOUSAND BTU PER HOUR MOTORIZED CONTROL DAMPER NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTDOOR HEAT PUMP OUTSIDE AIR OWNER SUPPLIED CONTR. INSTALLED POINT OF CONNECTION RETURN AIR RETURN AIR GRILLE REVOLUTIONS PER MINUTE ROOFTOP UNIT SUPPLY AIR SUPPLY GRILLE STATIC PRESSURE SIDEWALL SUPPLY GRILLE TO BE DETERMINED TRANSFER GRILLE TYPICAL UNIT HEATER VARIABLE FREQUENCY DRIVE VENT TO ROOF VARIABLE VOLUME AND TEMPERATURE ELECTRIC WALL HEATER SCHEDULE ID BRAND NAME MODEL NUMBER KW VOLTAGE LOCATION EH 1-4 KING PAW1215 1.5 115/1 RESTROOMS FAN SCHEDULE ID BRAND NAME MODEL NUMBER CFM SP HP/AMP FLOW V/PH SOUND RATING DUCT LOCATION EF 1-4 NUTONE AEN110 92 .25 0.3 A CV 115/10 1.3 SONES 4"0 RESTROOMS EF-5 BROAN 508 270 - 1.7 A CV 115/10 7.0 SONES 10"0 BREAKROOM SPLIT SYSTEM HEAT PUMP SCHEDULE ID BRAND NAME MODEL NUMBER COOLING(BTUH) HEATING(BTUH) LIQUID LINE SUCTION LINE SEER VOLTAGE/PHASE HSPF MCA MOCP WEIGHT LOCATION & NOTES MINIMUM RATED MINIMUM RATED OHP-B & C DAIKIN 4MXS36RMVJU - 36,000 - 36,000 - - 17.7 208/1 12.2 23.9 25 139 LBS GROUND MOUNTED OHP-1 DAIKIN RX18NMVJU 5,500 20,000 5,500 24,000 - - 18 208/1 9.0 18.3 20 97 LBS UNDER DECK OF MAIN FLOOR OHP-A DAIKIN 3MXS24RMVJU - 24,000 - 24,000 - - 18 208/1 12.5 21.9 25 137 LBS GROUND MOUNTED IHP-1 DAIKIN FTX18NMVJU - - - - 1/4" 1/2" - 208/1 - - - 26 LBS LOFT IHP-1C DAIKIN FTXSO9LVJU - - - - 1/4" 3/8" - 208/1 - - - 20 LBS STORAGE 109 IHP-1A,2A,3C DAIKIN FTXS12LVJU - - - - 1/4" 3/8" - 208/1 - - - 22 LBS CONF. 203 OFF. 204, STORAGE 104 IHP-3A,2B,3B DAIKIN FTXS15LVJU - - - - 1/4" 1/2" - 208/1 - - - 31 LBS SAMPLES 201,COFFEE 206, BREAK 211 IHP-1B DAIKIN FTXS18LVJU - - - - 1/4" 1/2" - 208/1 - - - 31 LBS SAMPLES 205 IHP-2C DAIKIN FTXS24LVJU - - - - 1/4" 5/8" - 208/1 - - - 31 LBS STORAGE 107 NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. HVAC LEGEND INLINE EXHAUST FAN(S) [CD 101 ROOFTOP EXHAUST FAN t ! 1111 SIDEWALL EXHAUST FAN ■ VAV FAN BOX CEILING EXHAUST FAN r OM GAS METER ZD12 VVT DAMPER �- 0 THERMOSTAT T-BAR SUPPLY DIFFUSER T-BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER a HARDLID RETURN GRILLE FD FIRE DAMPER FSD FIRE SMOKE DAMPER VOLUME DAMPER �-�- SD SMOKE DETECTOR FLEXIBLE DUCT SA/RA ROUND DUCT UP ) ROUND DUCT DOWN DIFFUSER TAG ()•) REVISIONS No changes shall be mace to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review. *INDOOR UNITS POWERED OFF OF OUTDOOR UNITS. HVAC NOTES 1. DUCT INSULATION TO MEET THE REQUIREMENTS OF SECT- ION C403.2.8 OF THE 2015 WSEC AND SECTION 604 OF THE IECC (INTERNATIONAL ENERGY CONSERVATION CODE). 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3. DUCTWORK-MAINTRUNK IS R-4.2 IN CONDITIONED SPACES AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2015, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2015, SECTION C403.3.1. 5. - EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON -SITE FOR INSPECTIONS. 6. ALL HVAC EQMT. TO BE LABELED TO THE SPACE SERVED. 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF C408 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, SYSTEM BALANCE REPORT, AND A COMMIS- SIONING REPORT. 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC C403.2.8. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER SEAMS SHALL BE SEALED. 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS. 11. WSEC FORMS, DUCTING PLANS, BALANCING FEATURES, AS WELL AS VENTILATION REQUIREMENTS (AS PER TABLE 403.3.1.1, 2015 IMC MINIMUM VENTILATION RATES) AND OCCUPANCY, ALONG WITH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. SCOPE OF WORK JOB# 19027 1. INSTALL (5) EXHAUST FANS. 2. INSTALL (4) ELECTRIC WALL HEATERS. 3. INSTALL (4) OUTDOOR SPLIT SYSTEM HEAT -PUMPS. 4. INSTALL (10) INDOOR SPLIT SYSTEM HEAT -PUMPS. Permit SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing ra Gas Piping City of Tukwila BUILDING DIVISION RL COP No. / Plan review approval is subject to errors and omissions Approval of construction documents does • not auth live the violation of any adopted code or ordinance. Receipt of approved Field Copy and Conditions is acknowledged: By: /( /a Date: REVIEWED FOR CODE COMPLIANCE APPROVED MAR 08 2019 y City of Tukwila BUILDING DIVISION RECEIVED) CITY OF TUKWILA MAR 05 2019 PERMIT CENTER PENDING CITY APPROVAL, ffERZTE10[11 - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTORS LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2128 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING-2001 PRINT/PLOT DATE: DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: SHEET NUMBER: oo o-riS WT VJ J cr CC 3/5/19 19027 (7 CONF 302 / / / / IHP-1 E OPEN 301 / / / / NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. L r1 1 LOFT HVAC PLAN SCALE:1/4"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED MAR 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 0 5 2019 PERMIT CENTER MEY1-2 E ELT0©EJ: - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTORS LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING 2001 REVISION DESCRIPTION W 0 cc PERMIT ISSUE d CO PRINT/PLOT DATE: DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: SHEET NUMBER: -1 co co 0) cr LLI J CC CD 3/5/19 ARW HH HH 19027 D SAMPLES 201 MN • i% • CONE 203 ( IHP-1A ( IHP-2A OFFICE 204 RECEPTION i ( OHP-1 UNDER DECK • 202 SAMPLES 205 ( IHP-3A ) OHP-A ) ( OHP-B ) OHP-C ) ( IHP-2B 1 COFFEE 206 I D -D K nlJ 1L ( IHP-3B _JO BREAK 211 EWH-1 ( EWH-3 MEN 207 EF-1 ( EF=2 - WOMEN 208 MEN 210 ( EF-3 WOMEN EWH-2 1 209 1 ( EF-4 ( !EWH-4 L1 ( EF-5 ) REViEVVzED FOR CODE COMPLIANCE APPROVED MAR 082019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 05 2019 PERMIT CENTER NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. MAIN FLOOR HVAC PLAN SCALE:1/4"=1'-0" PENDING CITY APPROVAL EEJI EoT:©EJ - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING 2001 PRINT/PLOT DATE: DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: SHEET NUMBER: 3/5/19 ARW HH HH 19027 ( IHP-1C STORAGE LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. STORAGE STORAGE I.T./SEFVER ( IHP-2C ) BASEMENT HVAC PLAN SCALE:1/4"=1'-0" MECH/ ELEC 105 STORAGE 103-1 HALLWAY STORAGE REViEV:-:D FOR CODE COMPLIANCE APPROVED MAR 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 0 5 2019 PERMIT CENTER PENDING CITY' APPROVAL - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTORS LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING 2001 PRINT/PLOT DATE: DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: SHEET NUMBER: 00 T' co 0) %- Q CD CC LLI CC O 3/5/19 ARW HH HH 19027 Scope of Work: Site Location: Parcel #'s: Site Size: Remodel Area: Number of Stories: Type of Construction: Building Height: r Remodel existing showroom building, which will include updates for accessible access and to add accessible restrooms 10411 Martin Luther King Jr Way S Tukwila, WA 98118 032304-9213 68,249+/- Square Feet (1.57+/- Acres) main floor=2529, basement=2102, loft=590 Total=5,221 Two Stories with Mezzanine Type V-B 32'-0" +/- 10 f T E r 1— 1J1 30' Fire: Zoning: Occupancy Group: Allowable Area: Parking Allowances: Plumbing Analysis: Energy Code: ESE Non -Sprinkled Light Insdustrial Mercantile - M (Showroom), Office - B, and storage S-1 Per Table 506.2 - Base Allowable Area = 9,000 S.F. - Warehousing: 1 space per 2,000 sq. ft. usable floor are minimum. - Office: 3 per 1,000 sq. ft. usable floor area min. 5,221 sf Occ B = 16 Stalls Required / 25 Stalls Provided 5,221 sf Occ B = 53 occupants, 27 male, 26 female Male - (2) Water Closets, (2) Sinks Required Female - (2) Water Closets, (2) Sinks Required Male - (2) Water Closets, (2) Sinks Provided Female - (2) Water Closets, (2) Sinks Provided Per pre -application meeting, building remodel does not change the use, so the existing building envelope can remain unchanged. New Mechanical and Electrical separate submittals will need to meet WSEC 2015 0 30 60 90 Owner Project Manager Civil Engineer/ Landscape Architect Architect Structural Engineer General Contractor Plumbing/Mechanical Electrical Mutual Materials, Inc. 605 119th Ave NE Bellevue, WA 98005 Phone: (425) 452-2363 Contact: Mike Jones Vector Development Company 11335 NE 112nd Way, Suite 105 Kirkland, WA 98034 Phone: (425) 968 - 5115 Contact: Tyler Litzenberger Barghausen Consulting Engineers 18215 72nd Ave S Kent, WA 98032 Phone: (425) 251-6222 Contact: Daniel K. Balmelli, PE Tahoma Design Group 535 Dock Street, Suite 211 Tacoma, WA 98402 Phone: (253) 284-9680 Contact: James K. Carleton, AIA AHBL Inc. 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Phone: (253) 383-2422 Contact: Daniel L. Booth, PE, SE Northway Construction 1433 Valentine Ave. SE #102 Pacific, WA 98047 Phone: (253) 735-8100 Contact: Colby LeClaire License: NORTHCI905CQ Exp: 02/18/2020 TBD/Design Build TBD/Design Build 9G_ 5• VICINITY MAP (N.TS.) rawin' Iniex CIVIL Under separate cover LANDSCAPING Under separate cover ARCHITECTURAL Sheet Title CS-R Cover Sheet / Site Plan A1.01R Basement Floor Plan A1.02R Main Floor Plan A1.03R Loft Floor Plan A2.01R Restroom Plans and Elevations A3.01R Stair / Ramp Plans and Sections STRUCTURAL Sheet S0.01R S0.02R S1.01R 52.01R 0 Title Structural Notes Special Inspection and Standard Details Foundation Plan and Overall Section Foundation and CMU Details S.BOEING ACCESS RD 'Af* MARTIN LUTHER KING JR WA S Showroom Remode UI o Mike Jones (425) 452-2363 co 4-1 d 18 .5:1: la1p " � m G AEI 09 slog ,15 HAIM Issue Set & Date: CO N CO 0 z .0 0 2170719.00.20 Cover Sheet v cn cu 17) RECEIVED CITY OF TUKWILA MAR 05 2019 PERMIT CENTER REVIEV;t FGI t DE COMPLIANCE APPROVED MAR 08 2319 City of Tukwila BUILDING DIVISION 0 (71 'd ® Q 11) v 0 0 0 it Q:\2017\2170719\00_PRM\CAD\2170719_R-COVER-SHT.dwg, CS, 7/22/2018 11:11:42 PM, JCARLETON, DWG To PDF.pc3, ARCH full bleed D (36.00 x 24.00 Indies), 1:1 SCALE: 1"=30'