Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M19-0035 - NELSON RESIDENCE - GAS FURNACE AND MINI SPLIT
NELSON RESIDENCE 12222 46 AVE S M19-0035 �~\ `./ Parcel No: Address: Project Name. City of Tukwila �� Department '° Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 2¢6'431,3670 Inspection Request Line: 206'438'9350 Web site: http://www.TukwilaWA.Rov 0179000927 NELSON RESIDENCE MECHANICAL OTC PERMIT Permit Number, K1I9-0035 Issue Date: 3/6/2019 Permit Expires On: 9/2/2019 Owner: Name: Address: Contact Person: Name: NELSON yN|[HA[i[ 12ZJZ4GTMAVS'TUKYV|U\WA, 98178 GREENWOOD HEATING Contractor, Name: GREENWOOD HEATING &A/C Address 8ZS5ST4CYST'5EATTLE'WA, 98134 License No: GREEWHA9I2V7 Address: ''' Phone: (205)784'1818 Expiration Date: 2/3/2021 DESCRIPTION OF WORN GAS FURNACE AND MINI SPLIT INSTALL Valuation of Work: $13,000.00 Type ofWork: REPLACEMENT Fuel type: GAS Fees Collected: $299.44 Electrical Service Provided by: S[ATTLECITY LIGHT Water District: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVACZ9G'46B: VVAState Energy Code: 2017 2017 2017 2015 j 1 f I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Da Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL / • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, 1,1/1 98188 http://www.TukwilaWA.gov Mechanical PermitNo. MI — 0 0 Project No. Date Application Accepted: 1 1 Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 12222 46 AVE S Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: MICHAEL NELSON Address: 12222 46TH AVE S City: TUKWILA State: WA Zip: 98178 CONTACT PERSON — person receiving all project communication Name: SEE CONTRACTOR Address: City: State: Zip: Phone: Fax: Email: New Tenant: LI Yes LI ..No MECHANICAL CONTRACTOR INFORMATION Company Name: GREENWOOD HEATING Address: 825 S STACY ST City: SEATTLE State: WA Zip: 98134 Phone: (206) 784-1818 Fax: Contr Reg No.: GREENHA922U7 Exp Date: 02/0 2021 Tukwila Business License No.: BUS-0994724 Valuation of project (contractor's bid price): $ 13,000 Describe the scope of work in detail: GAS FURNACE AND MINI SPLIT INSTALL Use: Residential: New Replacement ...... Commercial: New Ell Replacement ...... Fuel Type: Electric EI Gas ra, Other: DUAL FUEL 1.1 \ Applicationaorms-Applications On Line42011 Applications \Mechanical Permit Application Revised 8.0-1 I.docx Revised: August 2011 Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace > 100k btu 1 Floor furnace Suspended/all/floor mounted heater Appliance vent Repair or addition to heat/retrig/cooling system 1 Air handling unit <10,000 efm Unit Type Qty Air handling unit >10.000 cfn Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — conm/industrial Unit Type Qty Fire damper Dil9user Thermostat Wood/gas stove :rttergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/I ,000,000 btu 30-50 hp/1,750.000 btu 50+ hp/I.750.000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Lxpiratiun of plan review — applications for which no permit is issued within 180 days following the date of'application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justiciable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY "II -TAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE I..AWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED D TO APPLY FOR THIS PERMIT. BUILDING OWNER t.)B AUTHORIZ AGENT: Signature: Date: 03/06/2019 Print Name: TONI CARLSON Day Telephone: (206) 784-1818 Mailing Address: 825 S STACY ST SEATTLE WA 98134 City State Zip r..tppttcataonv.hor s,Applicavors tTh Ltne.20I I Applications Mechanical PermRe' ed 8.9.1I,doca RcY s.ed Atrvs>t 2011 bh Page 2 01'2 DESCRIPTIONS 1 ACCOUNT PermitTRAK QUANTITY PAID $299.44 M19-0035 Address: 12222 46TH AVE S Apn: 0179000927 $299.44 MECHANICAL $285.18 PERMIT FEE R000.322.100.00.00 0.00 $252.03 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $14.26 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17098 R000.322.900.04.00 0.00 $14.26 $299.44 Date Paid: Wednesday, March 06, 2019 Paid By: SELECT AIR SERVICES Pay Method: CHECK 21843 Printed: Wednesday, March 06, 2019 2:42 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit $4i$1 NSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit inspection Request Line (206) 438-9350 (206) 431-3670 Project» Type of inspe titan: Address: 1 4 Date Called: Special Instructions: .Date Wanted: .m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. nspecto Date: REINSPECTI©N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Home Espanol Contact Search L&I Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries A-Z Index Help My L&I Workplace Rights Trades & Licensing GREENWOOD HEATING & AIC Owner or tradesperson Principals PORTER, MICHAEL, PRESIDENT PORTER, KELLEY LEE, VICE PRESIDENT Doing business as GREENWOOD HEATING & AIC WA UBI No, 602 259 014 825 $ Stacy St SEATTLE, WA 98134 206-365-3313 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GREENHA922U7 Effective — expiration 03/27/2008— 02/03/2021 Bond Federated Mutual Ins Co Bond account no. 0772642 $12,000.00 Received by L&I Effective date 09116/2016 09/07/2016 Expiration date Until Canceled Bond history Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9363113 Received by L&I Effective date 06/19/2018 08/01/2018 Expiration date 08/01/2019 Insurance history Savings No savings accounts during the previous 6 year period. ....................... the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. ... Tax debts Help us improve No L&I tax debts are recorded for this contra may be recorded by other agencies. License Violations license during the previous 6 year period, but soma Infraction no. EPORU00393 Issue date 05/18/2015 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electricalltelecommunication installation or alteration as referenced in WAC 296-46B-901. Satisfied RCW/WAC 19.28.101 RCW Violation amount $1,000.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 043,142-00 Doing business as GREENWOOD HEATING & AIR CONDIT Estimated workers reported Quarter 4 of Year 2018 "Greater than 100 Workers" L&I account contact T1 / TYRONE COLEMAN (360)902-4807 - Email: COTI235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects, Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bld No debarments have been Issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 06/12/2013 Inspection no. 316775709 Location 825 S Stacy St Seattle, WA 98134 Violations C� Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve