Loading...
HomeMy WebLinkAboutPermit M19-0038 - AZ TRADING INC - WALK-IN COOLER / FREEZER AND EXHAUST FAN FOR BATHROOMAZ TRADING INC 3425 S 146TH ST M19-0038 0 Parcel No: Address: Project Name: �°^�vx °�� Tukwila "~U� v�u x ��m^���o�� � of Department of Community__—Development_ G3UOSouuhcenterBoulevard, Suite #100 Tukwila, Washington 9D188 Phone: 206~431-3670 Inspection Request Line: 206~438'9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT 0040000827 Permit Number: K419'0038 AZTRADING INC Issue Date: 3/21/2019 Permit Expires On: 9/17/2019 Owner: Z13OSDUPONT DRROOF CORP 0F WA, ANAHE|K4'VVA 92806 Contact Person: Name: PETER DANG Contractor: Name: License No: Lender: Name: 35255[H|CAGOST.SEAlTLE WA, 98118 UNIVERSAL APP&[OMR[FGUI 35255CH|CAG0ST'SEAlTLE WA, 98118 ''' Phone: (206)334-5801 Expiration Date: 10/4/2019 DESCRIPTION DFWORK: INSTALL WALK-IN COOLER AND FREEZER, INSTALL GLASS DOOR FREEZER AND EXHAUST FAN FOR BATHROOM Valuation of Work: $5,000.00 Type ufWork: NEW Fuel type: ELECT Fees Collected: $264.12 Electrical Service Provided by: SEAlTLECITY LIGHT Water District: 125 Current Codes adopted by the City of Tukwila: International Building Code Edition; International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Sign National Electrical Code: WACities Electrical Code: VVA[J96~46B: : Date: —,�.—.�y � � �+ |hearbycertify that I have read and examined this permit and know the same to be true and correct. All provisions oflaw and ordinances govemin8thiswnrkwiUbecmnp|iedwhh,whethprspeciGedhereinornot The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction nrthe performance ofwork. |vmauthorized tusign and obtain this development permit and agree tothe conditions attached tothis permit. Signature: Print Name: -- Dat -, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended orabandoned for aperiod ufl8Odays from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shaUbedoneinconfunnancewiththeVVashingtonStateDui|dingCodeandthe Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion ofthis requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (ZO6'4]1,367O). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance cxgranting ofapermit shall not beconstrued tobeupermit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City nfTukwila shall not hpvalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. O; `MECHANICAL PERMIT [OND0ONS~~* 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (I06/431'3h7O). ln: Manufacturers installation instructions shall beavailable onthe job site atthe time nfinspection. 12: Afire alarm system isrequired for this project. The fire alarm system shall meet the requirements of wfP.A.7Zand City Ordinance #Z437. 14: Maintain automatic fire detector coverage per m.F.P.A.72. Addition/re location ofwalls, closets or partitions may require relocating and/or adding automatic fire detectors. (NFPA72'l7.5.3l)(EXTENDHEAT DETECTION TOTHE WALK-IN COOLER AND FREEZ[R.) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. mowork shall commence until afire department permit has been obtained. (City Ordinance #Z437)(|F[9Ul.Z) 15: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #Z437} 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407. 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 7: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 8: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 9: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 12: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 13: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL CITY OF TUKWIC Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: 3 --- -- I (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 3(42..c So. (cal si" 174((,„,114 Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: CYCC-ye____ Address: `-C S o •-0.a x(,, City: City: _\_-_v_siti \ \ State: kr a Zip: G r CONTACT PERSON — person receiving all project communication Name: py.77,fi O. _421et Address: ;c-( _f City: 5..—dg.77*_- State: State: - 17 Zip: '1,4 Phone: I Email: New Tenant: ID Yes 11.. No MECHANICAL CONTRACTOR INFORMATION Company Name: /.//v7.67‘. ,im/ixii2cfp#7, Address:?"-ei 0,,,,_.., - city:. j-wfie State: Zip: / Phone: geK.,r, tax: Contr Reg No.:///44e 9:3_TO/Dir,.._ 7 zz Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: 7/t/‘ 4°C1 06.4 ,4fr(07 ,4z- /262-0, 4) Use: Residential: New 0 Replacement El Commercial: New 0 Replacement Fuel Type: Electric D Gas Other: HAApplications\ Forms -Applications On Line \2016 ApplicationslMechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code, Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules, Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING NE OR AU Rf ED AGENT: Signature: Date: S — Print Name: $0(k MOtiv"\ Day Telephone: 20(e, —4 -00(0 s- Mailing Address: ‘50.-A9 Vertfr*) SO -1-1/K(AAkctVi 1E VC ity State Zip HAApplicat ionsWorms-Applicat ions On Line12016 Applications \Mechanical Permit Application Revised 1-4- 16.docs Revised: January 2016 hh Page 2 of 2 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $264.12 M19-0038 Address: 3425 5 146TH ST Apn: 0040000827 $264.12 MECHANICAL $253.96 PERMIT ISSUANCE BASE FEE R000 322,100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00,00 0.00 $170.02 PLAN CHECK FEE R000 322 102.00.00 0.00 $50.79 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17127 R000 322 900.04.00 0.00 $10.16 $264.12 IMININOMMINIMMININIMINIMMINIMMONINIIIIII•11111111010111•1•••••=1•11111111111011.1•••••••••• Date Paid: Friday, March 08, 2019 Paid By: FRESH & GREEN Pay Method: CHECK 4032 Printed: Friday, March 08, 2019 3:18 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT 10. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje- .4 -Type lectiln•. ! j Address: `.5125 J} ate Called: Special Instructions: mate Wanted: '-' .� a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: APR®V'f�tervAlfth c/ -4_ i -t Inspector: Date:-/ 9 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project Type Type of Inspection: tisit irctfAALCAL FM Pa- Addr ess: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. Li Corrections required prior to approval. COMMENTS: p . A PPfcilCP elm- 0 Ptowir AltreP r-ot-s--z244.)//i, G- 'TfJ Nitl-- . e>V7-,i2e:›06? AiCfRIC-0-Riti--770 /9XiCitt)/Z0,0 in Cs-f2_001jp - Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspechon. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: /PeAle70•Vie/t1--Ant,V Date Called: Address: - r25- 51 /X%°14/ Special Instructions: - Date Wanted: —. a.m. p.m. Requester: Phone No: . Approved per applicable codes. El Corrections required prior to approval. CO MENTS: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: specialn uc n : Date Wanted: a.m. p.m. Requester: Phone No: 11 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 5outhcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: ROOG44- 1.4 MCC-171•PMCA Address: 3 26 ' Date Called: / Special Instructions: Date Wanted: — a.m. P.m. Requester: Phone No: Approved per applicable codes. Li Corrections required prior to approval. COMMENTS: Cr 0 Z--e A - I ft-FRAZ)Vg-D Inspector: Date: REINSPECTION FEEREQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY° PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0038 DATE: 03/08/19 PROJECT NAME: AZ TRADING INC SITE ADDRESS: 3425 S 146 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AtAi c 16,11 Building vision ft Fire Prevention Public Works Structural Planning Division Permit Coordinator Ilk PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 03/12/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Approved with Conditions DUE DATE: 04/09/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 11] Fire 0 Ping El PW D Staff Initials: 12/18/2013 HUITI e [.spanol Contaot Safety & Health Claims & Insurance Washington State Department of k Labor & Industries A-ZIndex Help T+1,,o L&1 Workplace Rights Trades & Licensing UNIVERSAL APP & COM REFG LLC Owner or tradesperson Principals SIN, DENH CAY, MANAGER PANG, KUEN SHING, AGENT PANG, KUEN SHING, PARTNER/MEMBER (End: 09/08/2011) Doing business as UNIVERSAL APP & COM REFG LLC WA UBI No. 602 436 330 3525 S CHICAGO ST SEATTLE, WA 98118 206-349-0358 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties COMMERCIALIINDUSTRIAIJREFRIG License no. UNVAPAC954NJ Effective — expiration 08/11/2005-- 10/04/2019 Bond American Contractors Indem CO Bond account no. 100351103 $6,000,00 Received by L&I Effective date 10/04/2017 10/04/2017 Expiration date Until Canceled Bond history Insurance Sentinal Insurance Company LTD Policy no. 52SBAAB3857 $2,000,000.00 Received by L&I Effective date 07/30/2018 08/28/2018 Expiration date 08/28/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve 60'-0" 12'-10" 2'-0" I/////////////////////// / WALK -IN -FREEZER - PMANU,FACTURED //)////�//////////// L STEEL ANGLE AT THIS SIDE ONLY /////////////////////////7// / / / / - MANUFACTURED / / PANEL/ / / / / / L STEEL ANGLE AT 3 SIDES / v / / / / / / WALK -IN -COOLER / / / / / / / / / / / /////////////4///////////// OTHER WALLS & FEATURES NOT SHOWN FOR CLARITY 7-DOOR FREEZER SCALE: 1/4" = 1'-0" -C I'-O» 0 7-0 BZT030L6B BOHN FOR COOLER BZT030L6B BOHN FOR FREEZER BZT030L6B BOHN FOR 7-DOOR FREEZER 6" CONC. PAD, 2500 PSI COMP. STRENGTH WALL PANEL L12'X12"X s, A36 STEEL #8X3/4" PHSMS @12"O.C. HILTI KB-TZ g"x3" @24"O.C.,TYP. ( 2"min. INTO CONC.) EXIST. CONC. SLAB L1l"X11"X 1" 2 2 16 A36 STEEL #8X3/4" PHSMS @12"O.C. (INSIDE) FLOOR PANELS CONNECTION AT FLOOR & WALL PANELS NTS NOTE: SEE COOLER MANUFACTURE PLANS FOR DETAILS NOT SHOWN HILTI KB-TZ 8X3" @ EACH CORNER,TYP. ( 2" min. INTO CONC.) CONC. PAD REVISIONS No No changes shall be made to the of work witnout prior approval of the Tukwila Building Division. NOTE: Revisions wih require a new plan submittal and may include additional plan COMP" ESSOR UNIT (CONNECTION�DETAIL NTS SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical [l Electrical C',sltambing DIV Gas Piping City of Tukwila BUILDING DIVISION FIL COPY Permit No. I Ct ` (v- t Plan review approval is subject to errors ano omissions Approval of construction aocuments.. for auth . rize the violation of any adopted code of ordinance. Receipt of approved Fielo Copy and conditions isedQea: By. Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAR 15 2019���> BUCLDINGof TDIVI$ N HOME TECH 4946 131 ST PL SE BELLEVUE, WA T: 206-778-2431 'N G viAsSr ,e‘4(v° �a 32229 �jSTEg LI o " ..c n., F. I. FRESH & GREEN PRODUCE 3425 S 146TH ST, TU K ILA, A 98168 REVISIONS DATE RECEIVED CITY F U WILA MAR 08 2019 DESIGN: Y.S. DRAWING: H.H. CHECK: Y.S. DATE: MAR 4, 2019 SCALE: AS SHOWN SHEET: 1 V 1