Loading...
HomeMy WebLinkAboutPermit M19-0060 - THE ADECCO GROUP - SUPPLY DIFFUSERS, RETURN GRILLES AND DUCTWORK This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M19-0060 ADECCO GROUP 14220 INTERURBAN AVE S DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers individuals’ privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW DR1 Generally – 5 U.S.C. sec. under section 42.56.070(1) of the Washington 42.56.070(1) 552(a); RCW State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW account numbers, which are exempt from 13 DR2 Financial Information – 42.56.230(5) disclosure pursuant to RCW 42.56.230(5), RCW 42.56.230(4 5) except when disclosure is expressly required by or governed by other law. Personal Information – Redactions contain information used to prove RCW Driver’s License. – RCW identity, age, residential address, social security 42.56.230 (7a DR3 number or other personal information required to 42.56.230 & c) apply for a driver’s license or identicard. (7a & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney-Client Privilege – disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); RCW 5.60.060(2)(a); RCW which protects attorney-client privileged DR4 RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. ADECCO GROUP 14220 INTERURBAN AVE S M19-0060 Parcel No: �~^�xx ^�� Tukwila *~U~� v�n o U�nxm��na Department of Community Development 63UUSnuthxenterBoulevard, Suite #1OO Tukwila, Washington 9Q188 Phone; 206-431'3670 Inspection Request Line: 206'438'9350 Web site; http://www.TukwilaWA.gov 3365901881 Project Name: THE ADE[[0GROUP MECHANICAL PERMIT Permit Number: M19'0050 Issue Date: 4/22/2019 Permit Expires On: 10/19/2019 Owner: Address: Contact Person: Name: Contractor: Name: License No: Lender: Name: l0lS]RDAVE #9O0INTEGRATED REAL DAN|ELNM PSR-HVAC&MECHANICAL SERVICES POBOX 27073'SEATTLE,WA, 98165 PSRMVK85922N] Phone: <205>367'2500 Phone: (206) 367-2500 Expiration Date: 4/21/2020 DESCRIPTION OF WORK: DEMO (l)SUPPLY DIFFUSER AND (3) RETURN GRILLES. RELOCATE (1)SUPPLY DIFFUSER AND (4) RETURN GRILLES. INSTALL (3) NEW SUPPLY DIFFUSERS AND ASSOCIATED DUCTWORK PER PLAN. Valuation of Work: $8,651.00 Type ofWork: NEW Fuel type: ELECT Fees Collected: $317.44 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKvV|LA Sewer District: TUKVV|LA Current Codes adopted bythe City nfTukwila: International Building Code Edition: international Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: international Fuel Gas Code: National Electrical Code: VVACities Electrical Code: VVAC296-468: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Sign y Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not, The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and a!neetothe conditions attached tothis permit. ' 5igna e: Print Name: ^�/���/� Dat�-r/�°�/./ This permit shall become null and void if the work bnot commenced within 18Odays for the date ofissuance, nrif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements' cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion ofthis requirement. 4: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 5: VALIDITY OFPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ufthe City ofTukwila shall not bevalid, The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: 'I'VIECHANICAL PERMIT CONDITIONS' 7: All mechanical work shall beinspected and approved under aseparate permit issued bythe City ofTukwila Permit Center (2O6/431-3670). 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2n6)438-935q 1800 MECHANICAL FINAL 0701 R0UGH'|NrNECHAN|[AL CITY OF TUKI4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. , TY \ CA —00 (Q () Project No. Date Application Accepted: 14--/Ce— ‘1 Date Application Expires: /0 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE OCATION 336590188l King Co Assessor's Tax No.: Site Address: 14220 INTERURBAN AVE S Suite Number: 130 Floor: 1 Tenant Name: The ADECCO Group PROPERTY 0 NER Name: SHELBY COMPANY LLC Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Daniel Kim Address: 3132 NE 133RD ST City: SEATTLE State: WA Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Email: daniel.kim@psrmechanical.com New Tenant: Ij Yes LJ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: PSR MECHANICAL Address: 3132 NE 133RD ST City: SEATTLE State: WA Zip: 98125 Plxme: (206) 367-2500 Fax: (206) 368-6856 Contr Reg No.: PSRHVMS924JT Exp Date: 04/30/2020 Tukwila Business License No.: BUS-0993498 Valuation of project (contractor's bid price): $ 8,651 Describe the scope of work in detail: Demo (1) supply diffuser and (3) return grilles. Relocate (1) supply diffuser and (4) return grilles. Install (3) new supply diffusers and associated ductwork per plan. Use: Residential: New Replacement CI Commercial: New 121 Replacement El Fuel Type: Electric IZ Gas Other: 1-1:1ApplicationsTorms-Applications On Line\ 2016 ApplicationsWeehanical Permit Application Revised I-4-16.docx Revised: January 2016 Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays, A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. Thc extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (cwTent edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING LER fl AUTIJORIZED AGENT: Signatur Print Name: Daniel Kim Mailing Address: 3132 NE 133rd St Date: 04/16/2019 Day Telephone: (206) 367-2500 Seattle WA 98125 City State Zip H:\Appalions\Forms-Applications On Line\2016 Applieations1Mechanical Permit Application Revised I-4-16.docx Revised; January 2016 Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $419.32 EL19-0332 Address: 14220 INTERURBAN AVE S 130 Apn: 3365901881 $101.88 ELECTRICAL $97.03 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $97.03 TECHNOLOGY FEE $4.85 TECHNOLOGY FEE R000.322.900.04.00 0.00 I $4.85 M19-0060 Address: 14220 INTERURBAN AVE S 130 Apn: 3365901881 $317.44 MECHANICAL $305.23 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $211.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $61.05 TECHNOLOGY FEE $12.21 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17416 R000.322.900.04.00 0.00 $12.21 $419.32 Date Paid: Tuesday, April 16, 2019 Paid By: PSR-HVAC & MECHANICAL SERVICES Pay Method: CHECK 013263 Printed: Tuesday, April 16, 2019 2:45 PM 1 of 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. 'I=RMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Btvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Pro` ct: Ty e % In ection: Address: -._ 0►ate ailed: peciai Instruc ons: ate ante p.rfc. Requester: Phone No: 1 Approve. per = plicable codes. Corrections required prior to approval. C#MIENTS: nspec Date: REINSPECTI©N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431670 Permit Inspection Request Line (206) 438-9350 Project:+ Type of Inspection: Address: J4270-�'- Date Caned: Special Instructions: Date Wanted: � +► �� h� V p.rna Requester: Phone No: z' ? O 7o / proved per applicable codes. 0 ENTS: Corrections required prior to approval. nspecto Date: REINSPECTION FEE paid at 6300 Southce R UIRE). Prior to next inspection. fee must be Blvd., Suite 100. Call to schedule reinspection. AIR BALANCE DATA SHEET PSR Building A Mechanical Efficiency and Sustainability Service Logic Company REMARKS PROJECT: Fairway Center Addecco Group PROJECT it: P5386 ROOM # OPENING SIZE ZONE REQUIRED CFM TEST CFM 1 TEST 2 CFM TEST 3 CFM FINAL CFM ZD1-4A 1 Linear 10 175 275 130 130 ZD down to 20% 2 Linear 10 75 275 120 120 3 Linear 10 100 250 130 130 4 Linear 10 175 275 120 120 ZD 1-4 B 5 Linear 10 300 200 150 150 6 Linear 10 270 180 140 140 7 Linear 10 300 200 140 140 ZD 1-4D 8 Linear 10 150 120 120 120 150 9 Linear 10 150 120 120 120 150 10 Linear 10 150 110 110 110 135 ZD 1-4B 11 8x8 8" 150 150 150 150 150 Replaced ZD damper was not 12 8x8 8" 150 145 145 145 145 Shaft 13 8x8 8" 150 135 135 135 135 ZD 1.3B 14 Linear 10 250 250 250 250 15 Linear 10 150 150 150 150 16 Linear 10 150 150 150 150 INSTRUMENT USED: Alnor Balometer And. Balome er SERIAL #: ABT7011703(An 3863 TESTED BY: Scot � J f'f'{ DATE: 4125119 SYSTEM NO. See above ADDRESS: 14220 Inturban AveS Tukwila WA 98168 Suite 130 PAGE: eh% PERMIT COORD COPY CI PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0060 DATE: 04/16/19 PROJECT NAME: THE ADECCO GROUP SITE ADDRESS: 14220 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: f\V° Building Division PrIVI Fire Prevention Planning Division Public Works Structural Permit Coordinator 111 PRELIMINARY REVIEW: DATE: 04/18/19 Not Applicable Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews DUE DATE 05/16/19 Approved with Conditions r Denied (ie: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW EJ Staff Initials: 12/18/2013 PSR-HVAC & MECHANICAL SEPtCES Hone Etipali 01 COntact Page 1 of 2 Search L&I Safety & Health Claims & Insurance CpWashington State Department of Labor & Industries A-Z Index Help My IATI Workplace Rights Trades & Licensing PSR-HVAC & MECHANICAL SERVICES Owner or tradesperson Principals BAVINS, NEIL JONATHAN, PRESIDENT AUSTIN, MATTHEW W, VICE PRESIDENT STEINKE, CRAIG, CHIEF EXECUTIVE OFFICER O'DONNELL, STEPHEN 0 (End: 04/12/2012) RIST, STEVEN L (End: 04/12/2012) O'MALLEY, JAMES J, MEMBER (End: 04/14/2014) HOGERTY, REAGAN P, MEMBER (End: 04/14/2014) Doing business as PSR-HVAC & MECHANICAL SERVICES WA UBI No 602 811 195 PO BOX 27073 SEATTLE, WA 98165 206-367-2500 KING County Business type Corporation Goveming persons INC MSHC MATTHEW AUSTIN; NEIL BAVINS; SRUN KHOU; CRAIG STEINKE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no, PSRHVMS924JT Effective — expiration 04/30/2008— 04130/2020 Bond International Fidelity Ins Co Bond account no. 0649932 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/28/2014 03/26/2014 Expiration date Until Canceled Help us improve httns://secure lni unv/verifv/Detail acny9I TIII=n7R1 1 1 OcRiT TC=PCPT4N/1.4CCYM1TR,C A Nit, A /11/1111 0 PSR-HVAC & MECHANICAL SEP CES Insurance Page 2 of 2 XL INSURANCE AMERICA INC $1,000,000.00 Policy no. RGD3001475 Received by L&I Effective date 04/02/2019 04/01/2019 Expiration date 04/01/2020 Insurance history Savings (in lieu of bond) Received by L&I 04/30/2008 Release dale N/A Savings account ID $12,000.00 Effective date 04/30/2008 Impaired date N/A Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workerscomp premiums. L&I Account ID Account is current. 152 899-00 Doing business as PSR MECHANICAL Estimated workers reported Quarter 4 of Year 2018 "51 to 75 Workers" L&I account contact T1 / TYRONE COLEMAN (360)902-4807 - Email: COTI235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/06/2018 Inspection no. 317949390 Location 5413 Meridian Ave N Seattle, WA 98103 No violations ©Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. httos://secure.lni.wa.gov/verifv/Detail a cnx9I TRI=6119 R 1 1 1 95k T TC-=PCP I-ININ4CQ7d TT.R \Al= Help us improve A /1') 11010 HVAC LEGEND.- ABBREVIATIONS: t-----------------I THERMOSTAT LINE AC AIR CONDITIONING IMC INTERNATIONAL MECHANICAL CODE RISE ACF AIR CURTAIN FAN IPC INTERNATIONAL PLUMBING CODE I-CE-t RISE DIRECTION OF RISE FOR DUCT ADA AMERICAN DISABILITIES ACT ID INDIRECT DRAIN ADJ ADJUSTABLE IE INVERT ELEVATION 2412 DUCT (FIRST FIGURE DENOTES VIEW SHOWN) AFF ABOVE FINISHED FLOOR IN INCH AL ACOUSTIC LINED INSUL INSULATE; INSULATION 10x8 SINGLE LINE DUCTWORK INDICATES DUCT ALIGN ALIGNMENT 2412 --t WITH VIEW DIMENSION LESS THAN 12 INCHES AP ACCESS PANEL KW KILOWATT APPROX APPROXIMATELY KWH KILOWATIHOUR ARCH ARCHITECTURAL ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS L LENGTH DUCT TAKEOFF AVG AVERAGE LAT LEAVING AIR TEMPERATURE LB POUNDS BAS BUILDING AUTOMATION SYSTEM LF LINEAL FOOT �® SUPPLY DUCT TURNING TOWARD, UP BFF BELOW FINISH FLOOR LVG LEAVING BHP BRAKE HORSEPOWER SUPPLY DUCT TURNING AWAY BLDG BUILDING MA MIXED AIR BOD BOTTOM OF DUCT MAX MAXIMUM BOP BOTTOM OF PIPE MBH; MBUH THOUSAND BRITISH THERMAL UNITS PER HOUR �-� RETURN DUCT TURNING TOWARD, UP BTU BRITISH THERMAL UNIT MCA MINIMUM CIRCUIT AMPACITY BTUH BRITISH THERMAL UNITS PER HOUR MCC MOTOR CONTROL CENTER BV BALANCING VALVE MD MOTORIZED DAMPER EXHAUST DUCT TURNING AWAY MECH MECHANICAL CD CEILING DIFFUSER MFR MANUFACTURER CFM CUBIC FEET PER MINUTE MIN MINIMUM; MINUTE f-� EXHAUST DUCT TURNING TOWARD, UP CG CEILING GRILLE MISC MISCELLANEOUS Cl CAST IRON MTD MOUNTED RETURN DUCT TURNING AWAY CLG CEI CENTERLINE MTG MOUNTING ILING CO CLEANOUT N.C. NORMALLY CLOSED F O ROUND DUCT TURNING TOWARD, UP CONN CONNECT; CONNECTED; CONNEC11ON N.O. NORMALLY OPEN CONST CONSTRUCTION NC NOISE CRITERIA s ROUND DUCT TURNING AWAY CONT CONTINUOUS; CONTINUATION NIC NOT IN CONTRACT COORD COORDINATE NTS NOT TO SCALE IO OVAL DUCT TURNING TOWARD, UP CORR CORRIDOR CU CONDENSING UNIT OAT OUTSIDE AIR TEMP OVAL DUCT TURNING AWAY CU CUBIC FEET OD OUTSIDE DIAMETER IN CU IN CUBIC INCHES OH OVERHEAD OA OUTSIDE AIR DB DRY BULB TEMPERATURE CONICAL WYE DEG DEGREE P PUMP DET DETAIL PD PRESSURE DROP �- -I CONICAL TEE DIA DIAMETER P PHASE DIFF DIFFERENTIAL R PROPERTY LINE 4A VOLUME DAMPER(VD) DIM DIMENSION POC POINT OF CONNECTION DISCH DISCHARGE PRELIM PRELIMINARY ® FIRE SMOKE DAMPER(FSD) DN DOWN PRES PRESSURE DR DRAIN PRV PRESSURE REDUCING VALVE FIRE DAMPER(FD) DSD DUCT SMOKE DETECTOR PSI POUNDS PER SQUARE INCH DWG DRAWING PSIG POUNDS PER SQUARE INCH GAGE M�- MOTORIZED DAMPER(FD) EA EACH RA RETURN AIR EAT ENTERING AIR TEMPERATURE RECIRC RECIRCULATING DOUBLE LINE, LINED DUCT/ ACOUSTIC DUCT EF EXHAUST FAN RECT RECTANGULAR EFF EFFICIENCYREF REFERENCE RECTANGLE TO RECTANGLE FITTING (RIGHT) EG EXHAUST GRILLE REG REGULATOR ELECT ELECTRICAL REQD REQUIRED ELEV ELEVATION RG RETURN GRILLE ROUND TO ROUND HIGH MEDIUM VELOCITY FITTING EMERG EMERGENCY RL RE -LOCATE / ENT ENTERING RND ROUND ESP EXTERNAL STATIC PRESSURE RPM REVOW11ONS PER MINUTE ROUND TO ROUND FITTING EXH EXHAUST. RV RELIEF VALVE EXIST, (E) EXISTING EXP EXPANSION SCHED SCHEDULE LOW VELOCITY (PRESSURE) ROUND DUCT TAKE -OFF, SF SQUARE FEET TO SUPPLY DIFFUSER F FAHRENHEIT SG SUPPLY GRILLE FC FANCOIL SO SCREENED OPENING FCO FLOOR CLEANOUT SOV SHUT OFF VALVE RECTANGLE/ ROUND RADIUSED ELBOW DUCT FD FIRE DAMPER SP STA11C PRESSURE FIO FURNISHED AND INSTALLED BY OWNER SPEC SPECIFICATION FLA FULL LOAD AMP SPECD SPECIFIED FLEX FLEXIBLE SS STAINLESS STEEL RECTANGULAR 90' ELBOW W/ TURNING VANES TYPICAL FLR FLOOR STRUCT STRUCTURAL FOB FLAT ON BOTTOM SWG SUPPLY WALL GRILLE FOIC FURNISHED BY. OWNER INSTALLED BY CONTRACTOR SWR SUPPLY WALL REGISTER ECCENTRIC CONICAL DUCT REDUCTION F1 71NG FOT FLAT ON TOP FPM FEET PER MINUTE TBD TO BE DETERMINED FPS FEET PER SECOND TEMP TEMPERATURE CONCENTRIC CONICAL DUCT REDUCTION FITTING FSD FIRE SMOKE DAMPER TSTAT THERMOSTAT FT FOOT; FEET. THRU THROUGH 30X20 FU FIXTURE UNITS TOD TOP OF DUCT TOP TOP OF PIPE RECTANGLE TO ROUND FITTING GAL GALLON TIP TRAP PRIMER GALV GALVANIZED TS TEMPERATURE SENSOR GEN GENERAL TV TURNING VANE SOUND ATTENUATOR GND GROUND TYP TYPICAL GPH GALLONS PER HOUR TURNING VANES GPM GALLONS PER MINUTE V VENT VD VOLUME DAMPER H HEIGHT, HIGH VEL VELOCITY HP HORSEPOWER VERT VERTICAL HR HOUR VOL VOLUME FLEXIBLE DUCT HTG HEATING HVAC HEATING, VENTILATING, AND AIR CONDITIONING WB WET BULB TEMPERATURE THERMOSTAT OR TEMPERATURE SENSOR HZ HERTZ WEF WALL EXHAUST FAN WIG WATER GAGE 0 THERMOSTAT OR TEMPERATURE SENSOR (CEILING) IBC INTERNATIONAL BUILDING CODE W/ WITH IFGC INTERNATIONAL FUEL GAS CODE W/o WITHOUT 6 DUCT SMOKE DETECTOR WT WEIGHT ©O SUPPLY AIR DIFFUSER PIPINGO I-�-I ROUND SUPPLY AIR DIFFUSER LEGEND.- .� ® RETURN AIR GRILLE N.C. N.O. BALL VALVE 4 A AUTOMATIC AIR VENTLOAT VALVE C- PIPE DOWN - ® EXHAUST AIR GRILLE BALL FLOAT VALVE j MANUAL AIR VENT OPIPE UP N.C. N.O. � DIFFERENTIAL PRESSURE GAUGE ASSEMBLY -6- TEE DOWN -_ SIDEWALL SUPPLY AIR GRILLE BUTTERFLY VALVE -a TEE UP OR REGISTER N.C. N.O. 0 DIFFERENTIAL PRESSURE SENSOR ASSEMBLY III UNION SIDEWALL RETURN/EXHAUST AIR liII14 GATE I VALVE GAUGE W/ COCK GRILLE OR REGISTER N.C. N.O. II CLEAN OUT GLOBE VALVE P/T PORT N.C. N.O. I D REDUCER 4 PIPE WELL THERMOMETER I�-i WYE STRAINER N CHECK VALVE u F PLUG VALVE FLOW METER Q FLOW SENSOR 10 PRESSURE REGULATING VALVE 1 BTU METER W/ WELL SENSOR MOTORIZED VALVE ACTUATOR PRESSURE RELIEF VALVE SOLENOID VALVE ACTUATOR GENERAL NOTES: 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), WASHINGTON STATE ENERGY CODE (WSEC), INTERNATIONAL PLUMBING CODE (UPC), INTERNATIONAL FUEL GAS CODE (IFGC), INTERNATIONAL FIRE CODE (IFC), NFPA AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. CONTRACTOR SHALL COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 3. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE AND SERVICE FOR ALL MECHANICAL EQUIPMENT AND UNITS. REFER TO MANUFACTURER'S INSTALLA1ON GUIDE. 4. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. 5. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDI1IONS AND SHALL HAVE THE APPROVAL OF THE PROJECT MANAGER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. 6. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA/OCCUPATION SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 7. ALL EQUIPMENT, DAMPERS, PIPING, AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. COORDINATE LOCATIONS WITH ARCHITECT/OWNER/CONTRACTOR TO PROVIDE ACCESS DOORS. 8. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. 9. ALL EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE STATE OF WASHINGTON AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS REQUIRED TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. 10. VERIFY ALL THE MECHANICAL EQUIPMENT'S ELECTRICAL LOADS VOLTAGE/PHASE, ETC. WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 11. WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS ARE USED, BALANCING VALVES IN THE RETURN LINES ARE REQUIRED. A CHECK VALVE SHALL BE PROVIDED IN EACH RETURN TO PREVENT TEMPORARY REVERSAL OF FLOW. 12. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL WORK, ETC., SHOWN ON CONTRACT DOCUMENT DRAWINGS. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 13. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 14. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF ONE MANUFACTURER SHALL BE USED. 15. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 16. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 180 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY AS REQUIRED BY SECTION C103.6.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. 18. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 2015 WASHINGTON STATE ENERGY CODE (WSEC) NOTES 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN C403.2.3. 2. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.2.2 OF THE WSEC AND AS, DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2.1 AND C4082.2.2 OF THE WSEC AND CHAPTER 6 OF .THE IMC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.8 "DUCT AND PLENUM..." OF THE WSEC. DUCT TAPE NOT ALLOWED. 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 OF THE WSEC. 6. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER SEC11ONS C403.2.11.1 THRU 5 AND C405.8 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 7. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC. 8. IF NOT SPECIFICALLY STATED ABOVE, CONTRACTOR SHALL ;COMPLY WITH THE WSEC ITEMS THAT DO APPLY TO THIS PROJECT 9. ALL PIPING INSULATION SHALL CONFORM TO THE WSEC SEC11ON C403.2.9. 10. HVAC SYSTEMS SHALL BE COMMISSIONED IN FULL COMPLIANCE WITH THE WSEC SEC11ON C408 SYSTEM COMMISSIONING. 11. HVAC SYSTEMS SHALL BE EQUIPPED WITH 100% OUTSIDE AIR ECONOMIZERS AS REQUIRED BY SECTION C403.3 OF THE WSEC. 12. HVAC SYSTEMS WITH COOLING CAPACITY GREATER THAN 65,000 BTU/H SHALL BE EQUIPPED WITH INTEGRATED ECONOMIZERS AS REQUIRED BY SECTION C403.3.3.2 OF THE WSEC. 13. FRESH AIR INTAKE AND RELIEF/EXHAUST SHALL BE EQUIPPED WITH LOW LEAK CLASS 1A MOTORIZED DAMPERS AS REQUIRED BY SECTION C403.2.4.3 OF THE WSEC. 14. FAN AND PUMP MOTORS 7.5 HP AND GREATER SHALL BE EQUIPPED WITH A VFD AS REQUIRED BY SECTION C403.2.13 OF THE WSEC. FILE PY00�� Permit No. Plan review approval is subject to a ors ano I omissions. Approval of construction aoc ,meats dce� I not authorize the violation of any aaorled Code of 1 ordinance. Receipt of approved Ftelc Copy and cond ns Cknowled c: By ' Dat City of TUKWiia BUILDING DIVISION REVISIONS No Changes shall be made to the Scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review. PROJECT LOCATION GENERAL HVAC NOTES: 1. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT. ONLY. 2. INSTALL ALL DUCT MOUNTED SENSING AND CONTROL DEVICES IN LOCATIONS WITH STRAIGHT SEC11ON OF DUCT UP AND DOWNSTREAM AS RECOMMENDED. BY THE MANUFACTURER FOR GOOD ACCURACY AND ACCESSIBILITY. 3. COORDINATE AND PROVIDE ALL DUCT TRANSITIONS. REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCT DIMENSIONS BEFORE FABRICATION. 4. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION, AND SEISMICALLY BRACED AS REQUIRED. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE. 5. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS THE EXTENT OF THE REQUIREMENTS FOR THESE ITEMS. 6. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS 4'-0" (CENTERLINE) ABOVE FINISHED FLOOR. N011FY THE PROJECT MANAGER OF ANY ROOMS WHERE .THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. 7. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 8. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF THE STRUCTURE (WITHIN TRUSSES), WITH SPACE FOR INSULA11ON IF REQUIRED. 9. MAXIMUM LENGTH OF FLEXIBLE DUCTS. SHALL BE AS CODE PERMITS. BUT NO LONGER THAN 12 FEET. 10. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS. 11. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL VOLUME DAMPERS AND OTHER ITEMS LOCATED IN THE DUCTWORK WHICH REQUIRE SERVICE AND/OR INSPECTION. 12. ALL AIR DISTRIBUTION SUPPLY OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. 13. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 14. ALL FAN SYSTEMS WITH OVER 2000 CFM SHALL HAVE DUCT SMOKE DETECTORS IN THE RETURN AIR STREAM TO DISABLE FAN UPON SMOKE DETEC1ION DETECTION. DUCT SMOKE DETECTORS ARE NOT REQUIRED IN THE RETURN AIR STREAM WHERE ALL POR11ONS OF THE BUILDING SERVED BY THE AIR DISTRIBUTION SYSTEM ARE PROTECTED BY AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE .INTERNATIONAL FIRE CODE. THE AREA SMOKE DETECTION SYSTEM SHALL COMPLY WITH SECTION 606.4 OF THE IMC. DUCT/SMOKE DETECTORS SHALL BE LISTED BY AN APPROVED AGENCY AND FOR INSTALLATION IN AIR DUCTS PER IMC SECTION 606. 15. ALL MECHANICAL HEATING AND VENTILATION EQUIPMENT SHALL CONFORM TO SMACNA, LOCAL AND STATE REGULA1ONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). 16. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 17. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUND LINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT LINING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET IMC CHAPTER 6. 18. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUNDLINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT LINING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET IMC CHAPTER 6. ALL DUCTWORK TO BE CLASS-1 AIR DUCTS. CLASS-11 DUCTS SHALL NOT BE USED. SEPARATE PERMIT REQUIRED FOR: Mechlcal Electrical Plumbing L�J Gas Piping City of Tukwila BUILDING DIVISION SITE INFO RECEIVED CITY OF TUKWILA ADDRESS: 14220 INTERURBAN AVE S . APR 16 2019 TUKWILA, WA 98168 PERMIT CENTER OWNER: SHELBY COMPANY LLC PARCEL/TAX # 3365901881 LEGAL: HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7... SEE SHEET MO.1 FOR FULL LEGAL DESCRIPTION SITE VICINITY NTS «'- r I r_. L1A 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206)367-2500 Fax (206) 368-6856 PSRHVMS924JT 0 0 Q Z W CD zto W�= W J F_ U) 00 Cie) m U) W T- CIO W W Z� WWzm� r F_W v�F- vJ Q W � o `V N LL V Q 0 LL COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. Ilk- REVIEV�IED FOR CODE COMPLIANCE a7 APPROVED APR 19 2019 City Of Tukwila BUILDING DIVISION No. Revision/Issue Date Drawn By D. KIM Date 04/16/2019 Lead Tech Engineered By N. SINGER Date 04/16/2019 Project P5386 Sheet Project Manager N.S. MO.O Scale AS NOTED It KEY PLAN HVAC PLAN SUITE 130 - DEMO ,45£, s ` % �µ Art" < RECEIVED CITY OF TUKWILA APR 16 2019 r'ERI'EII;' i.EiNITi;;R -4--� Cam'. CL 0 U M U td ? •O ti7 q.r' MA ra�i U LJJ 1A V �• �{ ' A t rwww 0- -�T 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT O z 7 LU _ -� U) Lu I- Q 00 M�Q0) z'r-w=< . W z LU LL �' W z N H C) 11 >— N V�J � d' r ry LL COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. Drawn By D. KIM Date 04/16/2019 Lead Tech Engineered By N. SINGER Date 04/20/2019 [Project Sheet P5386 Project Manager N.S. M 1.0 Scale AS NOTED REVIEWED U No. Revision/issue DateNo. Revision/issue FOR ODE COMPLIANCE APPROVE® APR 19 2019 Ci4y of Tukwila UILDIIVG DIVISION RECEIVED CITE' OF TUKWILA APR 1 6 2019 PERMIT CENT -ER KEY PLAN 4-JJ ' tom: CL Ina 0ro ON Ct.1. U M LLJ *. Uls 120 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206)367-2500 Fax (206) 368-6856 PSRHVMS924JT L.L O z_ G7 W �" M drn r UJ ICY z Lu Wg � Z N H ^J {1 ♦�♦�� VJ Q C L- r COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. REVIEWED FOR ODE COMPLIANCE . ,,. APPROVED APR 19 2019 City of Tukwila BUILDING DIVISION No. Revlsion/Issue Date Drawn By �I D. KIM Date 04/16/2019 Lead Tech Engineered By N. SINGER Date 04/16/2019 Project Shoe P5386 Project Manager N.S.M2.0 Scale AS NOTED