Loading...
HomeMy WebLinkAboutPermit M19-0067 - TORRID - DUCTWORKTORRID 17580 SOUTHCENTER PKWY UNIT 21 M19-0067 Parcel No: Address: K~^�»x '�� Tukwila v��~� v�n o ��o���Kna Department of Community Development G3VVEowthmenterBoulevard, Suite #10O Tukwila, Washington 9Q188 Phnne:ZO6'431'@67U Inspection Request Line: 2O6-438'9350 Web site: http://www.TukwilaWA.gov 2623049110 Project Name: TORRID MECHANICAL PERMIT Permit Number: K419'0067 Issue Date: 8/I2/2019 Permit Expires On: 2/8/2020 Owner: Name; Address: Contact Person: Name' Contractor: Address: License No: Address: K|RTUKVV|LAO5ULLL 3333NEW MYDEPARK RD#1UOC/O NMCOREALTY CORP, PUBOX SOZ8 NEW HYQEPK,CA, llO4Z 1Z36R}RTOLAAVE, T0RRANCE'CA, 90501 5M|iSHDL[DEVELOPMENT LLC 28llFAIRVIEW AVE,SUITE lOOZ, SEA77LE,VVA 98102 SH|/SDL912K7 ''' Phone: (206) 777' OB7 Expiration Date; 6/11/2021 DESCRIPTION OFWORK: DUCT WORK ASSOCIATED W/TENANT IMPROVEMENT. Valuation of Work: $10,000.00 Type ufWork: NEW Fuel type: ELECT Fees Collected: $33877 Electrical Service Provided by: PUGETSOUND ENERGY Water District: H|GHL|NE7UKVY|LA Sewer District: TVKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: international Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signa 2015 2015 2015 2015 2015 National Electrical Code: vVACities Electrical Code: VVA[2964G13: WA State Energy Code: 2017 2017 2017 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: ` 1 eZ Date: •` I° This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL Tenant Name: /l%///c CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Mechanical Permit;N©. Project No. Date Application Accepted: Date Application Expires: p ires: (For o j.ceus onl 1 MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** ()CATION �y ` King Co Assessor's Tax No.: Site Address: / 75 o f,44/ (e-d7,- A� /47 Suite Number: 42/ Floor: New Tenant: Yes ..No PROPERTY OWNEI Name: Address: � ya(r ', e/% 9 •./e / j4// S7 City: e,,//p,oe, State: (s�7 ZJp� CONTACT PERSON - person receiving all project communication� / / Name: �.J 7—601 W ,c// Address: /0/36 /A /eYe. -� State: ed Zip: �U5j/ City: ,�l%�/1if/! Phone: /0,.7e 2- 75,.j2,Fax: Email: / iC� r,% elGol .) 4qq/ 4'0,1 MECHANICAL CONTRACTOR INFORMATION Company Name: 75 Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ /' �Uv Describe the scope of work in detail: ®Gl Cylk'/if ep "fort Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement Fuel Type: Electric 3..� Gas 64.05094 Other: H:\Applications\Forms-Applications 0n Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise - Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (7am-l0pm); Testing of backup generators during the day. PERMIT APPLICATION; NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER e ' AUTH 1 ' IZED .GENT: Signature: Print Name: JgeQd !✓else Mailing Address: /2.6AV,PAAve Day Telephone: City Date_ /16 t? 3do-7o,-7r.C2 C,9 .asa/ State Zip H:\Applicatiens\For ns-Applications On Line\2016 Applications\M Revised: January 2016 bh apical Permit Application Revised I.4.16.docx Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $2,146.40 D19-0142 Address: 17580 SOUTHCENTER PKWY Unit21 Apn: 2623049110 $1,694.96 Credit Card Fee $49.37 Credit Card Fee R000,369.908.00.00 0.00 49.37 DEVELOPMENT $1,568.42 PERMIT FEE R000.322.100.00.00 0.00 $1,543.42 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.0O TECHNOLOGY FEE $77.17 TECHNOLOGY FEE R000.322.900.04.00 0.00 $77.17 M19-0067 Address: 17580 SOUTHCENTER PKWY Unit21 Apn: 2623049110 $275.16 Credit Card Fee 8.01 Credit Card Fee R000.369.908.00.00 0.00 $8.01 MECHANICAL $254.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00,00 0.00 $221.28 TECHNOLOGY FEE $12.72 TECHNOLOGY FEE R000.322.900.04.00 0.00 $12.72 PG19-0066 Address: 17580 SOUTHCENTER PKWY Unit21 Apn: 2623049110 $176.28 Credit Card Fee $5.13 Credit Card Fee R000.369.908.00.00 0.00 $5.13 PLUMBING $163.00 PERMIT FEE R000.322.100.00.00 0.00 $128,00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $8.15 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.15 TOTAL FEES PAID BY RECEIPT: R18312 $2,146.40 Date Paid: Monday, August 12, 2019 Paid By: ALBERT GATLIN Pay Method: CREDIT CARD 06442G Printed: Monday, August 12, 2019 12:06 PM 1 of 1 YSTM5 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $1,222.01 D19-0142 Address: 17580 SOUTHCENTER PKWY Apn: 2623049110 $1,003.22 DEVELOPMENT $1,003.22 PLAN CHECK FEE R000.345.830,00.00 0,00 $1,003.22 EL19-0371 Address: 17580 SOUTHCENTER PKWY Apn: 2623049110 $114.43 ELECTRICAL $114.43 PLAN CHECK FEE R000.345.832.00.00 0.00 $114.43 M19-0067 Address: 17580 SOUTHCENTER PKWY Apn: 2623049110 $63.61 MECHANICAL $63.61 PLAN CHECK FEE R000.322.102,00.00 0,00 $63.61 PG19-0066 Address: 17580 SOUTHCENTER PKWY Apn: 2623049110 t40 75 •,, • PLUMBING $40,75 PLAN CHECK FEE R000.322,103.00.00 TOTAL FEES PAID BY RECEIPT: R17518 0.00 $40,75 $1,222,01 Date Paid: Monday, April 29, 2019 Paid By: JACOB WEBSTER Pay Method: CHECK 3310 Printed: Monday, April 29, 2019 11:51 AM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/12/2019 12:05:48 PM CREDIT CARD SALE VISA CARD NUMBER: **********7775 K TRAN AMOUNT: $2,146.40 APPROVAL CD: 06442G RECORD #: 000 CLERK ID: kandace X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER} Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 670 Permit Inspection Request Line (206) 438-9350 'Project: d Type of Onspec o : 7 Address: , 75'o Date Called: SpeciaI insrructsons: Date Wanted: • . p.m. Requester: Phone No: Approved per applicable codes. x 0 Corrections required prior to approval. COMMENTS: r] REINSPECT ON FEE REQUIRED. Prior to next inspectio fee us be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedu e reinspeclion. INSPECTION RECORD Retain a copy with permit 11 I 4)06 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367`0 Permit Inspection Request Line (206) 438-9350 Proje,.,. `Type of Inspection: Address: /7Q1iiJr Date Called: Special Instructions: Da Wanted: /-Z — 3 - ZO1 a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. nspector: Date: REINSPECT! N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter E31.vd.. Suite 100. Call to schedute reinspecton. INSPECTION RECORD Retain a copy with permit INS PECTI0N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: #r of Inspection: r Address: / es 11 Date C e d: Special Ins ti s: ate Wanted: a.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. nspecto Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cat( to schedule reinspection. Notation: ." ri> frs*'PERMIT COORD COPY° PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0067 DATE: 04/29/19 PROJECT NAME: TORRID SITE ADDRESS: 17580 SOUTHCENTER PARKWAY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: k\\ Building Division Public Works to\i‘ Lke),Aln Fire Prevention Structural Planning Division Permit Coordinator 40 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/30/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections ente in 6Revie\) (ie: Zonjng Issues) \(\ 10 0'0 M\J DUE DATE: 05/28/19 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire El Ping PW El Staff Initials: 12/18/2013 Home Espanol C:mil act Search L&I Safety & Health Claims & Insurance 4111114k Washington State Department of /Labor & Industries A-% I itrIcx I iv11) My IA.1 Workplace Rights Trades & Licensing SHILSHOLE DEVELOPMENT LLC Owner or tradesperson Principals GATLIN, ALBERT G, PARTNER/MEMBER YUKEVICH, MICHAEL A, PARTNER/MEMBER Doing business as SHILSHOLE DEVELOPMENT LLC WA UBI No. 602 310 597 2811 FAIRVIEW AVE E SUITE 1002 SEATTLE, WA 98102 206-777-2087 KING County Business type Limited Liability Company Governing persons ALBERT G GATLIN MICHAEL ANDREW YUKVICH; Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice TrainingAgent Not allowed to have apprentices. License Verify the contractors active registration / license / certification (depending on trade) and any past violations, Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SHILSDL912K7 Effective — expiration 05/27/2009— 06/11/2021 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 361188C $12,000.00 Received by L&I Effective date 05/27/2009 05/27/2009 Expiration date Until Canceled Insurance Wesco Insurance Co $2,000,000.00 Policy no. WPP1063302 Received by L&I Effective date Help us improve KEYED NOTES: 01 EXISTING LANDLORD PROVIDED GAS HEAT ROOFTOP UNIT TO BE REUSED — SEE SCHEDULE FOR AIR BALANCE AND REFURBISHING REQUIREMENTS. VERIFY EXISTING R.A. SMOKE DETECTOR, PROVIDE NEW IF REQUIRED. VERIFY EXACT LOCATION ON SITE. RELOCATE EXISTING THERMOSTAT AS SHOWN — MOUNTED AT 48" A.F.F, COORDINATE WITH ARCHITECTURAL SHEETS. TENANT CONTRACTOR SHALL CONFIRM OPERATION AND COMPATIBILITY WITH NEW TEMPERATURE SENSOR PRIOR TO REUSE. PROVIDE NEW AS REQUIRED BY SITE CONDITIONS. TENANT CONTRACTOR SHALL PROVIDE AND INSTALL NEW TEMPERATURE SENSOR (COMPATIBLE WITH EXISTING THERMOSTAT), MOUNTED AT 60" A.F.F, COORDINATE WITH ARCHITECTURAL SHEETS. EXISTING ROOFTOP UNIT TO BE ABANDONED IN PLACE. REMOVE ALL ASSOCIATED DUCTWORK AND ACCESSORIES. VERIFY ALL CONDITIONS ON SITE. FLEX. DUCT 5'-0" MAX. LENGTH. TYPICAL FOR ALL. VOLUME DAMPER AND SPIN —IN. TYPICAL FOR ALL. CONTRACTOR MAY, AT THEIR OPTION, REUSE EXISTING SUPPLY AIR DUCTWORK IN SPACE, PROVIDED IT IS OF EQUIVALENT SIZE TO NEW DUCTWORK SHOWN. ALL EXISTING DUCTWORK SHALL BE CLEANED PRIOR TO REUSE. CONTRACTOR SHALL REMOVE ALL UNUSED PORTIONS OF EXISTING DUCTWORK AND PROVIDE NEW INSULATION TO ENSURE COMPLETE COVERAGE. EXISTING TOILET ROOM TO REMAIN. CONTRACTOR SHALL BRING ALL EQUIPMENT AND COMPONENTS TO "LIKE NEW' CONDITION. PROVIDE NEW OF LIKE MODEL AND SIZE AS REQUIRED. VERIFY ALL CONDITIONS ON SITE PRIOR TO BID. kpeihotAe czey ce.Z -, . oG'7 CiT.uc/AJorK ` /y/,r,`�us-la• cam/ I --?&( teAvy-X MECHANICAL SYMBOLS LEGEND +r— SUPPLY AIR .—,v— RETURN AIR �-J'— EXHAUST AIR SUPPLY FLOW NO RIGHT — STANDARD BRANCH, NO SPLITTER — RETURN/EXHAUST FLOW TO LEFT ♦ S S BELLMOUTH WITH BALANCING DAMPER FLEXIBLE DUCT I S 1dl TURNING VANES ♦ F ♦ MANUAL VOLUME DAMPER MD ♦ ♦ MOTORIZED DAMPER 1 I FD ♦ r. FIRE DAMPER & ACCESS PANEL T I s— SUPPLY DUCT UP, POSITIVE PRESSURE W —N S RETURN DUCT UP, NEGATIVE PRESSURE S 0 EXHAUST DUCT UP, NEGATIVE PRESSURE '.—® SUPPLY DUCT DOWN, POSITIVE PRESSURE S--® RETURN DUCT DOWN, NEGATIVE PRESSURE +--5.1 S—J EXHAUST DUCT DOWN, NEGATIVE PRESSURE FLEXIBLE DUCTWORK CONNECTION TO UNIT ® SUPPLY DIFFUSER/REGISTER BLANKOFF INDICATED SHADED TYPE — NECK SIZE ® 375 SUPPLY DIFFUSER DIFFUSER AIRFLOW (CFM) 0 X-10 RETURN GRILLE/REGISTER TYPE — NECK SIZE 200 RETURN AIRFLOW (CFM) X-8 TYPE — NECK SIZE EXHAUST GRILLE/REGISTER 150 EXHAUST AIRFLOW (CFM) S—r›—i CONCENTRIC DUCT TRANSITION S ^ S ECCENTRIC DUCT TRANSITION ® SMOKE DETECTOR OQ THERMOSTAT ® TEMPERATURE SENSOR i' EXISTING DUCT TO REMAIN ' EXISTING DUCT TO BE REMOVED 0 POINT OF CONNECTION B-6"0 IF YOU HAVE ANY QUESTIONS REGARDING THE MECHANICAL PLANS, PLEASE CALL THE MECHANICAL DESIGNER. DESIGNER: PHONE/FAX: E—MAIL: CRAIG ENGLE 612-465-7680/612-465-7780 craig.engle@dunhomeng.com GENERAL NOTES A. INSTALL VOLUME DAMPER IN DUCT TAKE —OFF TO EACH DIFFUSER, GRILLE, AND REGISTER. B. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. CONTRACTOR MAY, AT HIS OPTION, REPLACE RECTANGULAR DUCTWORK SHOWN WITH ROUND, SPIRAL DUCT OF EQUIVALENT CAPACITY. C. IN GENERAL, ALL PIPING AND DUCTWORK SHALL BE RUN CONCEALED IN SUSPENDED CEILING SPACES AND IN SHAFTS PROVIDED UNLESS NOTED OR INDICATED OTHERWISE. D. VERIFY ALL DUCT CONNECTION SIZES TO FANS, COILS, AND EXISTING DUCTWORK. E. COOPERATE WITH THE OTHER TRADES TO ELIMINATE ANY CONFLICTS BETWEEN PIPING, DUCTWORK, STRUCTURAL, ELECTRICAL WORK, ETC. F. DIFFUSER, REGISTER, AND SPRINKLER HEAD LOCATIONS SHALL BE COORDINATED WITH LIGHT FIXTURE LOCATIONS AND SHALL BE IN ACCORDANCE WITH CEILING PATTERNS AS SHOWN ON ARCHITECTURAL REFLECTED CEILING PLANS. G. ALL SQUARE DIFFUSERS SHALL HAVE THE AIR VOLUME EQUALLY IN FOUR DIRECTIONS UNLESS INDICATED OTHERWISE. H. MECHANICAL CONTRACTOR TO VERIFY RATINGS OF ALL WALLS WITH ARCHITECTURAL DRAWINGS. SEAL PIPE PENETRATIONS TO MATCH THE WALL RATINGS. PROVIDE ALL SUPPLY AND RETURN DUCTS PASSING THROUGH FIRE RATED WALLS WITH APPROVED FIRE DAMPERS. I. RUNOUTS TO DIFFUSERS SHALL BE THE SAME SIZE AS THE DIFFUSERS NECK SIZE. J. TENANTS CONTRACTORS SHALL VERIFY WITH HVAC PLAN TO COORDINATE THE REQUIREMENT OF PLENUM RATED FIXTURES, PIPING, WIRING, ETC. FAILURE TO DO SO COULD RESULT IN THE REMOVAL AND REPLACEMENT OF THESE ITEMS AT NO ADDITIONAL COST TO THE TENANT — NO PVC PIPING ALLOWED IN PLENUM. K. CONTRACTOR SHALL STENCIL TENANT NAME AND SPACE NUMBER ON UNIT. L. THE TENANTS MECHANICAL CONTRACTOR SHALL GO TO THE SITE AND VERIFY THE SIZE, DESIGN, SUPPORT AND LOCATION FOR.. ALL EXISTING AND FUTURE MECHANICAL EQUIPMENT AND UTILITY TAPS PRIOR TO ANY EQUIPMENT ORDERING, WORK, DUCTWORK FABRICATION ETC. NOTIFY THE TENANTS PROJECT MANAGER OR PROJECT ENGINEER IMMEDIATELY WITH ANY DISCREPANCIES, FAILURE TO DO SO COULD RESULT IN EQUIPMENT AND/OR MATERIALS REPLACEMENT AT NO ADDITIONAL EXPENSE TO THE TENANT. M. ALL EQUIPMENT, INSTALLATIONS, AND MATERIAL SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES AND LANDLORD CRITERIA. N. REMOVE ALL UNUSED PIPING, DUCTWORK, AND ACCESSORIES — DO NOT ABANDON. O. VERIFY LOCATION OF ANY PENETRATION THRU ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING, AND FLASHING SHALL BE BY LANDLORD'S ROOFER AT MECHANICAL CONTRACTOR EXPENSE. P. PRIOR TO OCCUPANCY OF THE PREMISES, GENERAL CONTRACTOR IS REQUIRED TO PROVIDE AN AIR BALANCE REPORT. A MALL APPROVED, INDEPENDENT, CERTIFIED AIR —BALANCE COMPANY MUST PERFORM THE TEST REPORT. PROVIDE COPY TO MALL OPERATIONS DIRECTOR. 14/14 SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER 85 DEG F O.A.D.B. 0.A.W.B IADB 65 DEG F 75 DEG F GAINS SOLAR LOAD ROOF LOAD GLASS LOAD WALL LOAD LIGHTS PEOPLE PEOPLE (SENS) PEOPLE (LAT) INFILTRATION (SENS) INFILTRATION (LAT) MISCELLANEOUS VENTILATION (SENS) VENTILATION (LAT) SUPPLY FAN LOAD SENS. LOAD TOTAL LOAD TOTAL CFM 25690 6138 1511 1151 15042 43 9937 11610 833 (147) 21321 7087 (1497) 3262 98,097 108,064 4000 BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH WINTER OADB IADB 23 DEG F 70 DEG F LOSS 8590 BTUH 12591 BTUH 3564 BTUH 4998 BTUH 50438 BTUH (3262) BTUH TOTAL 77,220 BTUH VENT. 975 CFM OUTSIDE AIR CALCULATION OUTSIDE AIR CALCULATION BASED ON THE 2015 IMC AREA #1 — SALF5 0.12 CFM/SQFT. X 2682 SQ. FT. = 7.5 CFM / PERSON X 41 PEOPLE _ AREA #2 — STORAGE NET SO. FOOTAGE: 2682 322 308 VENTILATION (CFM): 630 NET SQ. FOOTAGE: 620 0.12 CFM/SQFT. X 620 SQ. FT. = VENTILATION (CFM): 75 AREA #3 — STORAGE NET SQ. FOOTAGE: 587 0.12 CFM/SQFT. X 587 SQ. FT. = VENTILATION (CFM): 71 VENTILATION SUBTOTAL: VENTILATION EFFECTIVENESS: MINIMUM VENTILATION REQUIRED: VENTILATION SUPPLIED: 776 CFM .80 970 CFM 975 CFM 20/14 D A-12"0 1330 350 A-12"0 A-12"0 24/16 / O HVAC PLAN 1/4" = 1'-0" 20/14 A-12"0 DIFFUSER, GRILLE & REGISTER SCHEDULE DIFF. TAG MOUNTING TYPE DESCRIPTION FINISH MANUF MODEL NO SIZE NOTES: A LAY —IN SUPPLY WHITE TITUS TMS 24" X 24" 1, 3, 4 B LAY —IN SUPPLY WHITE TITUS TMS 12" X 12" 1, 4 C DUCT MOUNT SUPPLY MILL TITUS TMR AS SHOWN 1 D LAY —IN RETURN WHITE TITUS PAR 24" X 24" 4 E SURFACE TRANSFER WHITE TITUS 350RL 18" X 12" 2 NOTES' AIR DIFFUSER WITH OPPOSED BLADE DAMPER. DEFLECTION RETURN/EXHAUST GRILLE. MOUNT FRAME (IF APPLICABLE) GRILLES, REGISTERS & DIFFUSERS IN SALES AREA MUST BE PAINTED TO MATCH CEILING COLOR. VERIFY COLOR WITH ARCHITECT. 1. SUPPLY 2. 35' 3. RAPID 4. ALL EXACT 16/14 18/12 ©10 —12"0 gRvJ!SONS ,Dan 53Q: to (i:l 1cnoer 1 M1nwAY glr n17Y;PC5000 V.V'C' the Bela' uta BuuAda¢5L D:o000v1 one wO reguir0 a1 nem olab 0110050000 plan re:: Permit. Npo. 56DrS{; 'rAIJ ooi nth, :e Yy: ‘yo 3coinance If: c:e,w, 10 Nci-- DO vo EXISTING ROOFTOP UNIT SCHEDULE (GAS HEAT/ELEC. COOL) MARK MFG/ MODEL DISCHARGE TONS ESP CFM OUTSIDE AIR CFM ENTERING AIR CONDITIONS GROSS COOLING CAPACITY (MBH) EER 6 ARI HEATING CAPACITY "�t, AFUE ELECTRICAL ACCESSORIES UNIT WEIGHT (LBS) TOTAL SENSIBLE INPUT OUTPUT ". VOLT/PH/HZ RTU-1 TRANE YCD120 VERTICAL 10 0.5 4000 975 78.0E DB 63.0E WB ® 90F AMBIENT EXISTING EXISTING EXISTING EXISTING EXISTING' EXISTING EXISTING EXISTING EXISTING NOTE: MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR OF THE EXISTING ROOF TOP UNIT AND ITS ACCESSORIES AS FOLLOWS,' BUT ARE NOT LIMITED TO: CLEAN ALL COILS, THE FILTERS AND BELTS, INSPECT, REPAIR OR REPLACE DRIVES, FAN BEARINGS, MOTORS, CONTROL COMPONENTS, VALVES AND ANY OTHER ITEM NECESSARY FOR A COMPLETE AND OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE PRIOR TO BIDDING AND VERIFY ALL EXISTING SITE CONDITIONS. WORK, EQUIPMENT, AND ACCESSORIES TO BRING EXISTING SYSTEM TO GOOD WORKING CONDITION SHALL BE COVERED UNDER CONTRACTOR'S ORIGINAL BID AND AT NO ADDITIONAL CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS PRIOR TO BID. 1. THE REPLACE PROPER 2. ALL EXPENSE. BRUCE M. CARLSON architecture • planning • interior design BRUCE M. CARLSON ARCHITECT, PLLC 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 CONTACT: MINDY KRESA torrid®cmarch.com 5/22 CONSULTANTS: Pill DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 wAx 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering SEAL: TORRID PARKWAY SUPER CENTER 17580 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE #21 STRIP CENTER - EXPANDED SHEET TITLE: HVAC PLAN REVISIONS LOG ORIGINAL ISSUE: 04/25/19 NO: DATE: BY: PROJECT NO: 0420732-001 DRAWN BY: CRE M1 COPYRIGHT BRUCE M. CARLSON ARCHITECT, PELC 2019