Permit M19-0096 - SOUND TRANSIT / TUKWILA LINK STATION - EXHAUST FAN, MOTORIZED DAMPER AND WALL GRILLE
SOUND TRANSIT 3651 SOUTHCENTER BLVD EXPIRED 12/17/19 M19-0096 Parcel No: 0 �~^�xx ~�� Tukwila "~U~� uxn . U�v^w��na Department of Community Development G3VVSouthcenterBoulevard, Suite #1O0 Tukwila, Washington 9O108 Phone:ZV6'4]1'367U Inspection Request Line: 3O6-43Q'9]50 Web site: httr)://www.TukwilaWA.gov MECHANICAL PERMIT 0043000300 Permit Number: W419-0096 Issue Date: 6/20/2019 Permit Expires On: 12/17/2019 Project Name: SOUNDTRANSIT [P5RTA(SOUND TRANSIT) 4O1S]ACK5ON6T'SEAJTLE,WA, 98104 Contact Person: Name: KAYLENEmELSON Address: lZ2lSECOND AVE N'KEN7,WA, 98032 Contractor: Name: HERMAN8JNCOMPANY LLP (GENERAL) Address: lZZl2NDAVE N'KENT,WA, 98032' Z945 License No: HERMACLO05BJ Lender: Name: Address: ''' Phone: (253)359-73,47 Phone: (200)575'9700 Expiration Date: 8/25/2820 DESCRIPTION DFWORK: FURNISH AND INSTALL EXHAUST FAN (EF'1) WITH ASSOCIATED DUCT AND ROOF JACK, FURNISH ONLY 0FdX1Z LOUVER FOR INSTACLATION BY OTHERS. FURNISH AND INSTALL MOTORIZED DAMPER AND WALL GRILLE. FURNISH ONLY OF ELECTRIC UNIT HEATER (EUH-1) FOR INSTALLATION BY OTHERS. Valuation of Work: $6,310.00 TypeofVVor : REPLACEMENT Fuel type: ELECT Fees Collected: $399,50 Electrical Service Provided by: SEA7TLECITY LIGHT Water District: 125 Current Codes adopted by the City of Tukwila: International Building Code Edition: international Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[Z96'46D: Code: Permit Center Authorized Signature: Laid Da I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development .er it and agree to the conditions attached to this permit. Signatu e: Print Name: Date: (o17.J1 L91 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT' CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ***MECHANICAL PERMIT CONDITIONS*** 7: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov chanical Permit No. i' j l / g— ©29 Project No. Date Application Accepted: CIWO (/9 Date Application Expires: i? (i// y for office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will riot be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 3651 Southcenter BLVD Sound Transit PROPERTY OWNER Name: Sound Transit Address: 3651 Southcenter BLVD City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: Kaylene.nelson@hermason.com King Co Assessor's Tax No.: 0043000300 Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2020 Tukwila Business License No.: BUS-0994464 Valuation of project (contractor's bid price): $ 6,310 Describe the scope of work in detail: • Furnish and install exhaust fan (EF-1) with associated duct and roof jack. Furnish only of 6x12 louver for installation by others Furnish and install motorized damper and wall grille. Furnish only of electric unit heater (EUH-1) for installation by others Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement 1 Fuel Type: Electric IZ Gas ❑ Other: IL Applications \Forms -Applications On Line\201 I Applications\ Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >] 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comrrt/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment 3 Boiler/Compressor QtY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 N R #! y AUTHO ED AGENT: Signature: Print Name: Mailing Address: 1221 2nd Avenue N Date: 06/05/2019 Day Telephone: (253) 359-7147 Kent WA 98032 City State Zip A:\Applications\Forms-Applications On Line1201 I Applications1Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 hh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $299.50 M19-0096 Address: 3651 SOUTHCENTER BLVD Apn: 0043000300 $299.50 Credit Card Fee $8.72 Credit Card Fee R000,369.908.00,00 0.00 $8.72 MECHANICAL $279.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $190.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $55.92 TECHNOLOGY FEE $11.18 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17823 R000.322.900.04.00 0.00 $11.18 $299.50 Date Paid: Thursday, June 06, 2019 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 299.50 Printed: Thursday, June 06, 2019 12:18 PM 1 of 1 SYSTEMS 0 CO CITY OF TUKWILA 0817340080802374404500 Date: 06/06/2019 12:17:53 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TnxN AMOUNT: $299.50 APPROVAL [U: 151523 RECORD #: 080 CLERK ID; Laurie X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWIL4 ETRAKIT 0200 SVUTH[ENTEn BLvD TUKWzLA' WA 98188 206-433'1870 CITY OF TUKWILA Date: 06/06/2019 VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: 12:17:53 PM CREDIT CARD SALE w**~***^^0057 $299.50 151523 000 Laurie Thank you! Customer Copy K City of Tukwila Allan Ekberg, Mayor Department of Community Development 11/1/2019 KAYLENE NELSON 1221 SECOND AVE N KENT, WA 98032 RE: Permit No. M 1 9-0096 SOUND TRANSIT 3651 SOUTHCENTER BLVD Dear Permit Holder: Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/17/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/17/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, '11 ?pi Bill Rambo Permit Technician File No: M19-0096 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 G SLIP PERMIT NUMBER: M19-0096 PROJECT NAME: SOUND TRANSIT SITE ADDRESS: 3651 SOUTHCENTER BLVD X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: /114)C, Building Division Public Works L DATE: 06/06/19 Revision # before Permit Issued Revision # after Permit Issued A, AyA- Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) Planning Division Permit Coordinator DATE: 06/11/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: reit Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 07/09/19 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping D PW 0 Staff lnitiais: 12/18/2013 Hume Espanol Contact Safety & Health Claims & Insurance A Washington State Department of kj Labor & Industries A-Z Index Help My 1.h1 Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; Certifications & Endorsements ILicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2020 Bond WESTERN SURETY CO Bond account no. 929381801 $12,000 00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Help us improve "' ° `. MECHANICAL LEGEND HOT WATER (HW) WASTE OR SAN. SEWER BRANCH - TOP CONNECTION BRANCH- BOTTOM CONNECTION BRANCH - SIDE CONNECTION FLOW DIRECTION FLOOR CLEANOUT (FCO) OR SURFACE CLEANOUT ISCO) AS INDICATED VENT THRU ROOF [VTR) GATE VALVE (GV) BUTTERFLY VALVE PRESSURE REDUCING VALVE (PRV) CHECK VALVE I HOSE BIBB FLOOR DRAIN (FD) ROOM TEMPERATURE SENSORrrHERMOSTAT ROOM TEMPERATURE SENSORITHERMOSTAT POINT 05 CONNECTION MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR GENERALCONTRACTOR MECHANICAL GENERAL NOTES i. STANDARD CURRENT TRADE PRACTICES & METHODS APPLY To 12 DOMESTIC PIPING SHALL BE INSULATED IN ACCORDANCE WITH THIS PROJECT. ALL WORK 13 TO MEET REQUIREMENTS OF ALL THE WASHINGTON STATE ENERGY CODE. DOMESTIC HDT WATER CURRENT CODE & LOCAL JURISDICTIONAL REQUIREMENTS AND PIPE INSULATION SHALL BE K=0.24, 1" THICK, EXCEPT RUNOUTS UP AMENDMENTS. THESE CODES INCLUDE BUT ARE NOT LIMITED TO TO 12'SHALL BE 1127HICK. DOMESTIC COLD WATER PIPE WASHINGTON STATE ENERGY CODE, INTERNATIONAL INSULATION SHALL BE K=0.24,112" THICK FOR PIPING V & LESS MECHANICAL CODE, INTERNATIONAL BUILDING CODE, UNIFORM - INCREASE THICKNESS BY 1/2" FOR PIPING EXPOSED DIRECTLY TO PLUMBING CODE, NFPA, INTERNATIONAL FIRE CODE, & LOCAL OUTDOOR CONDITIONS. JURISDICTIONAL REQUIREMENTS, COMPLYWITH ALL MANUFACTURER'S REQUIREMENTS. COORDINATE WITH OWNER'S 13, PROTECT PIPING INSULATION PER REQUIREMENTS OF VVSEC REPRESENTATIVE FOR ANY VARIANCES. C403.2.91 2. DRAWINGS ARE DIAGRAMMATIC ONLY & NOT INTENDED TO SHOW 14. VENTILATION SHALL BE PROVIDED PER IMC CHAPTER 4. ALL DETAILS OF THE WORK- VERIFY LOCATION & MEASUREMENTS OF ALL ITEMS ON THE JOB SITE PRIOR TO INSTALLATION. 15. SEAL & TEST ALL DUCTWORK AS REQUIRED PER IMC, WSEC CWRACTOR SHALL PROVIDE ALL OFFSE7S &ADDITIONAL C403.2.8.3 LEAKAGE REQUIREMENTS, & IBG VAPOR RETARDER DUCTWORK & PIPING AS NECESSARY TO AVOID STRUCTURAL REQUIREMENTS. DUCTWORK DESIGN PRESSURE IS V, ELEMENTS ON THE PROJECT. CONTRACTOR SHALL PRODUCE SHOP DRAWINGS & COORDINATE WITH OTHER TRADES. THERE 16. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS, SHALL BE NO ADDITIONAL COST TO THE OWNER FOR THIS COORDINATION OR FOR EXTRA MATERIAL REQUIRED IN ORDER TO 17 PROVIDE CLOSEOUT DOCUMENTS IN COMPLIANCE WITH C103.6 ACCOMPLISH THIS TASK. 18. PROVIDE WATER HAMMER ARRESTOR ON CW-HW PIPING SERVING 3. PROVIDE COMPLETE & FULLY -OPERATING SYSTEMS. P-1, P-2. 4. COORDINATE LOCATIONS OF ALL EQUIPMENT & APPURTENANCES 19- INSTALL TANKLESS WATER HEATER IN ACCORDANCE WITH WITH OTHER TRADES. MANUFACTURES RECOMMENDATIONS. 5ALL EQUIPMENT SHALL BE REGULARLY CATALOGED ITEMS OF THE 20. DOMESTIC WATER PIPING SHALL BE TYPE L COPPER ABOVE MANUFACTURER & SHALL BE SUPPLIED AS A COMPLETE UNIT IN GRADE AND TYPE K COPPER BELOWGRADE. FITTINGS SHALL BE ACCORDANCE WITH THE MANUFACTURER'S STANDARD WROT COPPER. BALL VALVE$ SHALL BE LEAL) BRASS, APOLLO SPECIFICATIONS, ANY OPTIONAL ITEMS REQUIRED FOR PROPER 94ALF-A OR EQUAL, INSTALLATION SHALL BE INCLUDED UNLESS OTHERWISE NOTED. 21. WASTE AND VENT PIPING SHALL BE NO HUB CAST IRON SOIL PIPE 6, ANY CUTTING, PATCHING & PAINTING OF BUILDING ELEMENTS & (ASTM A1388) WITH IRON FITTINGS. JOINTS SHALL BE CIEPI 310 WITH FINISHED SURFACES IS TO BE DONE BY THE GENERAL NEOPRENE GASKET AND STAINLESS STEEL CLAMP AND SHIELD CONTRACTOR. ASSEMBLIES CONFORMING To ASTM C12T7 SLOPE PIPING AT 1/4" PER FOOT. 7. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE. 22WATER AND WASTE PIPING SHALL BE SEPARATED BY A MINIMUM OF 12" BOTH VERTICALLY UP AND HORIZONTALLY. WATER PIPE 8. ALL EQUIPMENT SHALL BE LABELED PER PLANS & THE SHALL BE ABOVE WASTE PIPING. REQUIREMENTS OF THE SPECIFICATIONS. 23 PROVIDE CHROME PLATED STEEL PIPING ESCUTCHEON AROUND S. CAULK & FLASH ALL PENETRATIONS PER CODE. ALL PIPE PENETRATIONS, 10. ADJUSTING 9 BALANCING: ADJUST EACH PART OF SYSTEM TO 24. DUCTWORK SHALL BE INSULATED IN COMPLIANCE WITH WSEC ENSURE PROPER FUNCTICNING OF ALL CONTROLS & SPECIFIED C403.2.8 PROVIDE R-7 AT A MINIMUM, AIR DISTRIBUTION. LEAVE ENTIRE SYSTEM IN OPERATING 11. PROVIDE OPERATING & MAINTENANCE MANUALS (O&MS), RECORD DRAWINGS, & OWNER TRAINING. wo MANUFACTURER AREASERVED GREENHECK 1. PROVIDE UNIT WITH ROOF JACK MODEL R.14. 2. PROVIDE WITH BACKDRAFT DAMPER, 3. INTERLOCK WITH ELECTRICAL CONTACTOR OCCUPANCY SENSOR, PROVIDE ALL REQUIRED WRING ELECTRIC TANK WATER HEATER SCHEDULE UNIT PHYSICAL TANK NO MANUFACTURER MODEL AREA SERVED kW VOLT/PH EFFICIENCY % SIZE (GAL) T NOTES ELECTRIC UNIT HEATER SCHEDULE UNIT MANUFACTURER MODEL AREASERVED KVV VOLTIPH WEIGHT NOTES 1. PROVIDE UNIT WITH HEATER ASSEMBLIES, WALL CAN, AND GRILL, PROVIDE WITH SEPARATE PROGRAMMABLE THERMOSTAT. 2. INTERLOCK WITH PECO MODEL SB200-001 OCCUPANCY SENSOR PLUMBING FIXTURE SCHEDULE MANUFACTURER /MODEL NUMBERS PLUMBING CONNECTIONS WATERCLOSET TYPE, MFR., MODEL: FLOOR MOUNTED AMERICAN STANDARD MADERA FLOWISE MODEL 3461.001 16-IFZ'HEIGHT, EVERCLEAN SURFACE FLUSH VALVE: SLOAN "ROYAL" 111,ADA, 1.28-GALLON FLUSH. SEAT:OPEN FRONT, LESS COVER; BENEKE NO. 523SSICH WITH SrUF SUSTAINING CHECK HINGE. MISCELLANEOUS: FLUSH CONTROL SHALL BE MOUNTED FOR USE FROM WIDE SIDE OF WATER CLOSET AREA. HANDICAPPED- HEIGHT FROM FLOOR TOTOP OF SEAT SHALL BEA MAXIMUM OF 19"AND MINIMUM OF 17" TYPE, MFR., MODEL: WALL HUNG, 4" CENTERS, VITREOUS CHINA AMERICAN STANDARD "COMRADE"NO. 0124-024 CAULKFLANGETO FAUCET: CHICAGO FAUCETS MODEL NO 802-V317E66ABCP, 0.� GPM VANDAL RESISTANT, ADA COMPLIANT. WALL TRAP& TAILPIECE: MCGU IRE OR EQUAL, 1-1,172" CHROME PLATED CAST BRASS P-TRAP WITH CLEANOUT AND TAILPIECE SUPPLIES: LOOSE KEY QUARTER -TURN BALL STOP WITH FLEXIBLE BRAIDED STAINLESS STEEL RISERS; BRASSCRAFT HANGER: FLOOR -MOUNTED WITH CONCEALED ARMS. MISC: PROVIDE ADA INSULATION AND WRAP ON TRAP AND SUPPLIES NMI FREEZELESS QUARTER -TURN, NON -FREEZE WALL HYDRANT WITH INTEGRAL VACUUM BREAKER AND STAINLESS STEEL BOX, LOOSE KEY, HINGED LOCKING COVER, ADJUSTABLE WALL CLAMP, WOODFORD B-79 CONCEALED BOX TYPE TRIMLINE WALL HYDRANT, LOOSE KEY, CHROME FINISH, BACKIFLOW PROTECTED HIM MEN TRAP PRIMER FLUSH -MOUNTED ELECTRONIC TRAP PRIMINGASSEMBLY IN STEEL CABINET WITH ATMOSPHERIC VACUUM BREAKER, PRE-SET24-HOUR CHANGE, MANUAL OVERRIDE SWITCH, SOLENOID VALVE, 1000NNECTION; PRIMETIME MODEL PROVIDE ACCESS DOOR TO SUIT LOCATION, POWER CONNECTION 0.33 AMPS 120[10. MANIFOLD MEN FLOOR DRAIN JR SMITH MODEL 2510 WITH INTEGRAL TRAP AND PRIMING CONNECTION. PROVIDE FUNNEL ON FFD. 30% DESIGN REVIEW 60% DESIGN REVIEW PERMITSET C, 90% DESIGN REVIEW BID SET _ NG_ ISSUED FOR REVISION STRAZZARA APL= TRES WEST ENGINEERS, INC. ARCH11111=11111111 1 2001 Western Ave, Suite 200 PLANIN1111111111 Seattle, WA 98121 Phone: 253.472.3300 DA FIRE SPRINKLER GENEIV-%L NOTES 1. FIRE SPRINKLER CONTRACTOR TO CONNECT AND EXTEND PIPING FROM ADJACENT BLDG. AND PROVIDE ANEW WET SPRINKLER SYSTEt# FOR ABOVE AND BELOW CEILING AS REQUIRED BY NFPA 13 AND LOCAL JURISDICTION. 2. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH OTHER TRADES FOR PIPING ROUTING, COORDINATE THE LOCATION OF THE PIPING AND HEADS TO AVOID INTERFERENCES WITH LIGHT FIXTURES, HEATINGICOOLING EQUIPME�T, C RK AND ANY ARCHITECTURAL FEATURES. 3. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO INSTALL A COMPLETE WORKING SYSTEM MEETING NFPAA-Np ALL LOCAL CODES. FIRE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DESIGN AND CALCULATIONS FOR THE SYSTEM, AUJ PIPING SHALL BE STEEL GROOVED PIPING SHALL BE MINIMUM SCHEDULE 10 STEEL AND THREADED PIPING SHALL BE MINIMUM SCHEDULE 40 STEEL. EXPOSE[) HEADS SHALL BE CHROME PLATED SEMI RECESSED. UPRIGHT HEADS SHALL BE BRASS. DA SEQUENCE OF OPErv-%TION 1. PROVIDE PECO MODEL #T12000 OR APPROVED THERMOSTAT WITH PECO MODEL 88200-001 OCCUPANCY SENSOR INPUTS. TEMPERATURE SHALL BE ORIGINALLY SET AT 50'FADJUSTABLE FOR UNOCCUPIED MODE AND 72'F ADJUSTABLE FOR OCCUPIED MODE. INTE13LOCK THERMOSTAT WITH PECO MODEL 88200-001 OCCUPANCY SENSOR. 2- EF SHALL RUN CONTINUOUS WHILE OCCUPIED AND FOR 15 MINUTES AFTER OCCUPANCY. DURING EF OPERATION MOTORIZED MAKE-UP AIR DAMPER SHALL REMAIN OPEN. DAMPER SHALL CLOSE WHEN FAN IS DISABLED. ° SEPARATE PERMIT RE QUIRED FOR E3 Mechanical Electrical City of Tukw.la UILDING DIVISION E M 7' fT Al FOR CODE COMPLIANCE FREVIEMID APPROVED City of Tukwila BUILDING DIVISION M. STANI APPRMED. AS NOTED SITE LOCATION NO. METRO TRANSIT DIVISION TUKWILA INTERNATIONAL BLVD. STATION - TUKWILA, WA 98188 JULY 2018 DRIVER'S COMFORT STATION KGFROJECTROV E004ME16 ONE INCH AT FULL SIZE rity MECHANICAL LEGEND DRAWING ND Department of SCHEDULES AND MO.01 KC CONTRACT NO, IF NOT ONE INCH, SCALE ACCORDINGLY Transportation GENERAL NOTES ET NO OF 20 27 , C)() 0 o o E O c� d x tom F tN 30% DESIGN REVIEW 60% DESIGN REVIEW PERMIT SET 90% DESIGN REVIEW BID SET ISSUED FOR/ REVISION 6X12 GREENHECK ESD-202 7' THICK LOUVER. BAKED ENAMEL FINISH COLOR TO BE SELECTED TO MATCH BUILDING EXTERIOR. LOUVER TO BE ALUMINUM.D63" THICK PROVIDE WITH BIRD AND INSECT SCREEN WALL G T1 S MOD L35 L DUCT UP TO ROOF JACK SM MOTORIZED DAMPER OZ GREENHECK VCD-23 LOW LEAKAGE WITH 120V I I ILI ACTUATOR. INTERLOCRLOCAK WITH EXHAUST FAN N-0 PROVIDE ff'x8"ACCESS J�// PANEL FOR ACTUATOR EFIFM DRIVER 0 COMFORT STATION EUH-1 a 1 2 0,� MECHANICAL PLAN ENM IIIIIIII I SCALE: 12 -l'-Q' )MM 10/2017 Nw T R E S WEST ENGINEERS. INC. 4320.1 2702 SOUTH 42ND STREET, SUITE 301ST TACOW, WA 98409-7315 Phone: 253.472.3300 w Ares est.mn 711112018 stud'OMENG STRAZZARA A00= 2001 sstem Ave, Suite 200 Seattle, WA 98121 T 206.687.3797 )MM 11 / 2017 )MM 3/2018 )MM 7/2018 PP`D DATE ROOF JACK DETAIL SCALE: NONE CAULK AND INSTALL 3"x3`xl8 GAUGE ANGLE ALL AROUND CAULKING AND BACKER ROD (TYPICAL) FASTENERS: 114" PANHEACIED, 3" LAG, OR METAL SCREW, STAINLESS STEEL, MINIMUM PER SIDE. DO NOT FASTEN ON TOP OR B0770M OF LOUVER LOUVER TO BE REMOVABLE FROM EXTERIOR OF BUILDING WEATHERPROOF LOUVER AS SHOWN ON PLAN ASPHALT FLASHING: EXTEND OVER SILL EXTENSION AND MINIMUM 6"ON SIDES PROVIDE GALVANIZED SPOT WELD STRIP SUPPORT LOUVER ANGLE CLIPS BACK OF PLENUM, IPS ANCHORED TO STRUCTURE 11 SHEET METAL SCREW TO PLENUM. CAULK SCREW INSULATION' R-7 HEADS INSULATION TO DUCTWORK SHEET SHEET OF 3 BIRDSCREEN 0 o TRANSITION DUCT TO DUCT PER i PLAN IT'MINIMUM STEEL ATTACHED AT AND FIBERGLASS SECURE DO NOT SEAL BOTTOM OF LOUVER TO PLENUM. ALLOW FOR DRAINAGE ONE PIECE LOUVER SUPPORT/SILL EXTENSION, NO PENETRATIONS THROUGH EXTENSION. TURN UP ENDS 4". WITHOUT DRIP LIP EXTERIOR WALL - - - - - - - - - - - - ............ .... ..... . ..... ..... . ... .......... ...... ..... (MINIMUM) SLOPE BOTTOM 10 PER FOOT SPOT WELD su D , r l PR T. LOUVER SUPPORT/SILL EXTENSION, 20 GAUGE STAINLESS STEEL TURN EACH END UP 4" WITHOUT DRIP LIP AND FASTEN 1. @ I 4" WITH FLAT HEADED STAINLESS STEEL SHEET METAL SCREWS 118'"-lr2"x4" HARD RUBBER GLASS SUPPORT. MINIMUM OF 2 ALONG BOTTOM LEAVE GAPS FOR I DRAINAGE PLENUM SECURE TO BACK OF WALL WITH CONTINUOUS METAL CLOSURE ANGLE REVIEWED FOR Wx3"XI8GAUGE GALVANIZED CODE COMPLIANCE SPOT WELD CLOSURE ANGLE TO PLENUM APPROVED 3/4' irz, CAULK AND BACKER ROD. CAULK BOTTOM OF PLENUM TO STRUCTURE JUN 17 2019 45' NOTES: •City of Tukwila 1. GENERAUMECHANICAUHVAC CONTRACTOR TO COORDINATE INSTALLATION OF LOUVER WITH ARCHITECT PRIOR TO ORDER ING AND INSTALLING, BUILDING DIVISION WEATHERPROOF LOUVER INSTALLATION SCALE: NONE PMECT MWGER M. STANASZE& SGALE AS NOTED L9 METRO TRANSIT DIVISION TUKWILA INTERNATIONAL BLVD. STATION - TUKWILA, DRIVER'S COMFORT STATION WA 98188 DAlP JULY 2018 APPRMD. 4 t S17EL11CATM10, — nlflgCourdy MECHANICAL PLAN KCPROJECTW. E0043IE16 ONE INCH AT FULL SIZE MWINGNO IF NOT ONE INCH, SCALE Department of Transportation M1.01 KC CONTRAU NO: C01251cls sIaEETNo OF ACCORDINGLY 21 27 I I IT I �iI I I II I�111 I I I I , I I I 4" W UP O'' 2" W UP TO FF1Y 2' 2" V UP � III I I I I r l I I I I TO FCO I \ a II 7�UP TO F B \ 2" I L r =J._L 1 L nl I 12 _ j ( 2" W UP TO P_2 - T�� d `-'--------- r S PE RT COM O I I I i I -- ) 4 (E" W ! 4" W UP TO P-1 I 2"VUP r 4" W TO FCO 4" y 4 4" i 2 I }( I I , \ SLOPE 2% 1 0 3 a C O L 11_----- J SLOPE @ 2% I O C N p c 3 c � L .D m Y C •O � � - - - � o m in c FOUNDATION PLAN a 2 iD a o d A a w 1L n V YI SCALE: 12'<1'4r g �c O m 3 � v tf O O E_ v P Z t� y L W 30% DESIGN REVIEW SMR DMM 04 / 2017 GENERAL NOTE 1, SANITARY WASTE ROUTING AS SHOWN IS DIAGRAMMATIC AND SUBJECT TO CHANGE PER ACTUAL SITE CONDITIONS. CONTRACTOR SHALL FIELD VERIFY PRIOR TO PERFORMING ANY NEW WORK DISCREPANCIES AND OR REVISIONS SHALL BE NOTED ON SITE AS -GUILTS PLAN NOTES Ut PROVIDE WALL SLEEVE AND UNK SEAL PENETRATION. OCONNECT TO EXISTING WASTE. U3 REPLACE (E) CLEANOUT COVERS WITH NEW BRASS COVERS - ROOF AL 4" VTR CONNECT TO EXISTING CW. FIELDw114„ _ 1 _1!4" _ g 5 1 1/d" _ g g ^ q I g VERIFY LOCATION. PROVIDE BALL ccc���----�- C3' VALVE AND ACCESS PANEL AT 2" CONNECTION POINT. CEILING r_ ____!- _1 ' I SHUT-OFF VALVE ' AND 12x12 CEILING ACCESS PANEL 1 a 7' 8.5 2" �6 1rY' I i 1-1/4" ' I � ------I---------- 2'-4---' (/ L 8.5 1-114" _ 7.5 1 3/4" <2 i LP2I 1 1rr' �Ir2"41, 4FU M1.03 4VH 1 I 2"'V P 5 I P-1 CC4 I L� P-4 JANITOR ROOM FINISHED ! 2FU i 2FU ' 112' FINISHED FLOOR FLOOR 2"FD I 2"FFD I 4" ClO 4" FCO 4] 4" 2_ 2 2" 1 2" 2 4" 4 CONNECT TO EXISITING 4" 3 7' 2„ WIN JANITORS ROOM 5 4" 4" q" g d" SLOPE @ 2% m 60% DESIGN REVIEW SMR DMM 10 / 2017 wog PERMIT SET SMR DMM 11/2017 _��og Stud«'MEND DRAM 0 0 90% DESIGN REVIEW SMR DMM 3 / 2018 $TRAuQ1RA S j m BID SET HT DMM 712018 CHECKE T R E 5 WEST ENGINEERS, INC. � 2001 Western Ave, Suite200 o p i=� .. - �P�492,�8�9q, PLAMM Seattle, WA 98121 2702 SOUTH 42ND STREET, SUITE 41 ,q, rs"l" F'" S� CONSULME T: 206.587.3797 wU' TACOMA, WA 98409.7315 4'pi l REC�� ISSUED FOR/REVISION BY APP'D DATE Phone:253.472.3300 SIONAL —n R rc Iw .treswest- o 7/11/2018 rwhi IWA ml RISER DIAGRAM FIXTURE UNITS NOTED AS 2 WASTE & VENT RISER DIAGRAM SG,►E: one 11` 1? D a .... PROJECT M"GER M. STANASZEK SCALE AS NOTED LQ R RANSITDIVISION FPq [�KWILAINI/TE)RKNAL BLVD. STATION - TUKWILA, R D D ER'S COMFORT DATE JULY 2018 APPRO✓EO. SRELOCATIONNO Knteg County STATION ArvQL FOUNDATION PLAN FQ DRAWWO NO KC PROJECTEI6 ECONTRACT ONE INCH AT FULL SIZE Cc O_ ,. �� Department of ASTE/VENT DOMESTIC PIPING M1.02 1251CIO C01251C18 IF NOT ONE INCH, SCALE ACCORDINGLY Transportation RISER DIAGRAM SEfETNO DF 22 27 o HOT (INSULATED) ADA TRAP AND TAILPIECE COVERS COLD (INSULATED) FLEXIBLE RISER MIXING VALVE POWERS LFG480 BALL VALVE TEE CW STOP UNION OR TUBING CONNECTOR ESCUTCHEON T&P RELIEF �OA -III WH1 A EXPANSIONTANK TANK (ICI AMTROLST5C WATER HEATER ASME RATED POWER NOTES: Oq PIPE TO 2"FFD IN COPPER TYPE L. oINSTANT FLOW WATER HEATER M 1.03 SCALE: NONE ADJUSTABLE STRAINER HEAD STRAINER 15-0" CUT 1-1/2' RIGID INSULATION MIN. FROM ANY TO FIT. ATTACH WITH DUCT FINISHED GROUT (BY G.C.) FRESH AIR INTAKE TAPE SLOPED FLOOR CAULKTVANDAL-PROOF VENT CAP ---- I ---- CAULK FLASHING FLASHING DUCT TAPE . 1 I FLASHING COLLAR WITH 12"MIN. I WEEP HOLES 10" TRAP PRIMER ALL SIDES CONNECTION CONCRETE BY G.C. REMOVE STRAINER, I FLOOR DRAIN BODY I CONCRETE 6Y G.C. FLASHING FINISHED ROOF STRAINER HEAD, AND INSTALL STRAINER, STRAINER FLASHING COLLAR. STORE PIPE SIZE AS NOTED ON PLANS HEAD, AND FLASHING COLLAR FOR LATER INSTALLATION (SET FINAL ELEVATION) DURING CONCRETE POUR (STEP#1) AFTER CONCRETE HARDENS (STEP#2) NOTES: VENT PIPING; SIZE 1. COMPLETE INSTALLATION OF FLOOR DRAIN AND AS NOTED ON PLANS SETTING OF FINAL ELEVATION WILL NOT BE ALLOWED DURING INITIAL CONCRETE POUR. 2. DO NOT ALLOW GROUT PENETRATE WEEP HOLES AND FILL UP TRAP. MeFLOOR DRAIN INSTALLATION DETAIL 3 VENT THROUGH ROOF DETAIL 1.03 SCALE: NONE M1.D3 SCALE: NONE M1.03 PLUMBING FLOOR PLAN 1 2 4 1 St7u E 1/zLt' SCALE: ,a-1.4r - o 2 V DN. 18UP � . - _ __ _.. CONNECT TO EXISTING CW. FIELD 1/4" r VERIFY LOCATION. PROVIDE BALL _ i I VALVE AND ACCESS PANEL AT CONNECTION POINT. D ON PROVIDE SHUT-OFF VALVE -1 12x12 CEILING aAC SS PANEL / UP 1-1/4" CW DN II 1/2' CW DN DRIVER COMFORT STATION I O I M 03 4"V UP to-TOVTR& I �]'___�_�2 I 2 PLUMBING ABOVE CEILING PLAN 3 0 �.1 2 SQqm le iw SCALE: 1a41'4- GENERAL NOTE 1. SANITARY WASTE ROUTING AS SHOWN IS DIAGRAMMATIC AND SUBJECT TO CHANGE PER ACTUAL SITE CONDITIONS. CONTRACTOR SHALL FIELD VERIFY PRIOR TO PERFORMING ANY MEW WORK DISCREPANCIES AND OR REVISIONS SHALL BE NOTED ON SITE AS-BUILTS CAULK BEHIND FLANGE FOR WATERTIGHT SEAL INTEGRAL VACUUM BREAKER FINISHED WALL CW SERVICE (MAY BE SERVED FROM ABOVE OR BELOW -SEE PLANS) eFREEZE PROOF WALL HYDRANT DETAIL M1.03 SCALE: NONE eINTERIOR COLD WATER HOSE BIBB DETAIL M1.03 SCALE: NONE r— — BALL VALVE I I TRAP PRIMER VALVE EXPT'RF" I I ACCESS ON W ( ; L_ _ COORDINATE LAOCATION LL DFC 17 pfjiq W/G.C. AND ARCHITECTURAL PLAN OOR eTRAP PRIMER DETAIL SCALE: NONE 7/1 30% DESIGN REVIEW SMR DMM 0412017 DESIGNED: FAOXCTMANAGER: SCALE aAALA AS NOTED METRO NSIT ISION DATE 60% DESIGN REVIEW SMR DMM 10 / 2017 � M, SMR M. stANAszE � JULY 2018 s studio. ENG TUKWILA TERNATIONAL VD. ATION - ILA, WA 9818 PERMIT SET SMR DMM 11/20i7 �_ opav+wN: APrRovED srrELacATDNrIo. DRIVER'S 0 RTSTATI S 90%DESIGN REVIEW SMR DMM 3 / 2018 STRAZZARA SMR K' EPAq TE BID SET HT DMM 7 / 2018 PECKED. KC PROJEC J0 ONE INCHATFULL SIZE King County P LU B I N G F 04 R & AB aip NGNO: T R E S WEST ENGINEERS. T INC. AI�eR�. 2001 Western Ave, Suite 200 E00431E16 p C E I L I G PLANS R -� �,�.G�zea �4 w�u.«. Seattle, WA 88121 DMM ,• De artment of QUt Ep M 1.03 nog SOUTH ACOM , 98409-, 315 301 ISTL� COIaU11N/ T: 2D8.58T3797 No. ISSUEDFOR/REVISION BY APPO DATE TACDM4,WA982.33005 SIONdL RECOhA1EM1DB): KC CONTRACT NO,, Trans Transportation www.Phone: 253.4R.3300 C01251019 IF NOT ONE INCH, SCALE p PLUMBING DETAILS ' W OF www.treswesLcom 7/11/2018 ACCORDINGLY 23 27