Permit M19-0098 - FIRE STATION 51 - NEW HVAC SYSTEM.
TUKWILA FIRE STATION 51 17951 SOUTHCENTER PKWY FINALED 08/12/2020 M19-0098 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter I3oulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.sov MECHANICAL PERMIT 3523049008 17951 SOUTHCENTER PKWY Project Name: TUKWILA FIRE STATION 51 Permit Number: Issue Date: Permit Expires On: M19-0098 8/20/2019 2/16/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CITY OF TUKWILA 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 IVY LEVANGIE 20109 144TH AVE NE , WOODINVILLE, WA, 98188 JOHANSEN MECHANICAL INC. 20109 144 AVE NE , WOODINVILLE, WA, 98072 JOHANMI173PK Phone: (425) 481-2266 Phone: (425) 481-2266 Expiration Date: 2/2/2021 DESCRIPTION OF WORK: INSTALL NEW HVAC SYSTEM. Valuation of Work: $410,366,00 Type of Work: NEW Fuel type: ELECT Fees Collected: $4,698.56 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: NONE,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: -6(-666i Date: 0047 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions oflaw and ordinances governing this work will becomplied with, whether specified herein ornot. The granting ofthis permit does not presume tngive authority toviolate orcancel the provisions ofany other state orlocal laws regulating construction ortheperfnnnanoeofwork. |amauthorized tosign and obtain this development perr"dagree totheuapd|donsattached tothis permit. Dute: Print Name: / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All permits, inspection record card and approved construction documents shall bekept atthe site nfwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. 2: Manufacturers installation instructions shall beavailable onthe job site atthe time ofinspection. 2: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 4: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment o,appliance rests, S: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431'367O). 6: Type 1Hoods, the required grease duct leakage test and light test shall beperformed byaspecial inspection and testing agency inaccordance with |.K8�.Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)43B'93S8 2000 GAS PIPING FINAL 0703 &4ECHEQUIP EFF lQOO MECHANICAL FINAL 0609 P|P[/DUCT|NSULAA'0N 0701 ROUGH -IN MECHANICAL 8702 SMOKE DETECTOR TEST 1 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.goy Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: tp- I 1-- 9 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: (71 1 S Tenant Name: Cti.l��l o� ` (1„f PROPERTY OWNER Name: eikt., ....c;1/4 . k a. Address: Lysol.) S 1'v d City `/ W \ c, State:, , A n Zipp(. t gr. CONTACT PERSON — person receiving all project communication Name: ` t vi Address: ZI71 dal i 1•01 +L- hre- ) jC City: uyn7v� nJ i ! It State: . t► ,� Zip: pi 961 �I�Vet' Phone:14.5_ Li'4 _ ...2.6 Fax: '�I �t1n'1693 . 1 t Email: ill t 1,c c ] 4 Se►rn h•Aer.,i„., Suite Number: New Tenant Floor: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION' Company Name: \ U �q h.�� nA(. 1' `c t,„.,,,,, C 0,1 Address: \ D ct 04(4 44,— /� �� l City: W - ,"0,` ` e State: _ Zip: C, O Sr� tits ts -_147 1 _2.Z(Lp(o 4S 2,1 �..... 4 ContrReg No.�6NA4,3 pkT1'•t3(v ,2/2.ft Tukwila Business License No.: Sus — 0,7 S ti 1 ei ^ Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Use: Fuel Type: C Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Electric Gas Other: H:\Applications\rorms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor flunace Suspended/wall/floor mounted heater 13 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 0 Ventilation system ) Hood and duct Incinerator - domestic Incinerator - comm/industrial vel,. e)(1...ex Unit Type Qty Fire damper 1 4 Diffuser 1( 0 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Vg-dF ib Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu %-() 1 fle0S (2ecor'4-1(3 ) District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU ZED AGENT: Signature( Print Name: Mailing Address: Date: LP I 14./1 Lz-V esyie Day Telephone: - A0-(_1 oocitA 117 City State Zip HAApplicationsTorms-Applications On Line12016 Applications \Mechanical Permit Application Revised 1-4-16.clocx Revised: January 2016 bh Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $4,698.56 M19-0098 Address: 17951 SOUTHCENTER PKWY Apn: 3523049008 $4,698.56 MECHANICAL $4,517.85 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $3,581,13 PLAN CHECK FEE R000.322.102.00.00 0.00 $903.57 TECHNOLOGY FEE $180.71 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17860 R000.322.900.04.00 0.00 $180.71 $4,698.56 Date Paid: Tuesday, June 11, 2019 Paid By: JOHANSEN MECHANICAL, INC. Pay Method: CHECK 074746 Printed: Tuesday, June 11, 2019 10:54 AM 1 of 1 TEM5 ` Instructions �°� ��U �� ^ Forms FrQAf A/ J% / 1015Washington State Energy Code CompliammFu sfor Commercial Buildings including R2&R3over tories and all R1 Revised January 2017 Commercial Provision Chapters 1 - 5 of the 2015 Washington State Energy Code apply to all commercial occupancies, R-2 and R-3 occupanies greater than 3 stories above grade, and R-1 occupancy (all building heights), Intro This file, MECH15-v2.XLSM, has electronic compliance forms for mechanical provisions as defined in Sections C403, C4O4.C4O8.and Chapter 5.There are two companion files: ENV15+2.XLSM(Sections COD8.C402.Chapter 5.and Appendix A envelope requirements), LTG15-v3.XLSM (Section C405 and Chapter 5 lighting systems requirements). Energy This form is a compliance aid and is not a substitute for the full energy code text or specific jurisdiction compliance Code requirements. Users should refer to the code text and contact the local jurisdiction for complete information. The full 2015 VYSECcode text |uavailable for download from the wsEC*eboite hftn:/*`mw.ne000aoeneqv'cnden Training Refer to the NEEC website for instruction on how to complete all of the 2015 WSEC Compliance Forms. ��aok-�]� Go|e�this file hnmthe NEECwabsi\a�download ooyour oqmpumr VVhonopening the file henumtoEnable Macros, and ifapplicable, Enable Content. This file is an Excel workbook that contains multiple compliance forms and resources in Excel worksheets. Each wo,koheatisindicated byotab at the bottom of the screen. If the tabs are not visible, set the View in Excel to Full Screen. Overview You may visit each wvmoxeethvselecting it's tab. Most calculations are automated. Cells that display informational text and the results nfcalculations are write -protected and cannot beedited. Save Files This file issaved i"the same manner esany standard Excel file. Getting J���m�� Some forms have two pages. Both pages are available ooscreen when you select the tab for mform (wnrkoheeV.Use m U � 0o� �m U located b | �h first e�um qmm n onoonn page mmv epage. All general project information and the date are entered once on MECH-SUM. This information is automatically replicated onall other MECHforms. Only input cells are accessible. If you try to edit a write -protected cell an error message will appear requesting a password. A password IS NOT required to complete these forms. You may use the TAB key to move to the next input cell. xthe TAB doesn't take you where you want mgo, use your mouse mmove around the form. Avoid excessively long text strings when entering information. In some cases, text that extends beyond the available Input Cells space will not bovisible. |nmost cases the text will wrap within the cell. This may force part o,the form onto anew page. Tnenter the date, use this format: mm/UU/yyyy.For example, you would enter 7/1/2O13or12/21/2n14. Check boxes ran bechecked v,unchecked hyclicking inthe box with your mouse. Radio buttons (cinduo) allow only one inaset muoselected. Drop -down lists have anarrow at the right side ofthe cell. Click onthe arrow with your mouse and select the appropriate option. Use the delete button unyour comp utermclear adrop-down entry. When a form has a space for notes or explanatiorl,'click anywhere in the space to edit. Pexomzxml- ���zx Yvuoanpeoon*|iz��he�v,mo�i�ynu,mv�p�nyname.addn^oo.phono.vranyvthm,inh,rmaVvn.Thisis done by editing �h header fp� i Excel. �� "u � ��oe,o,=vn, " xoo. Many tables, such anfor listing proposed mechanical nysvomo, have certain number of lines available for entering Adding data. You may nomg more lines to enter all your information. Where this feature is avai|eh|e, you can add additional lines to 'Y' hand If the ^+^button, and the table by selecting the button on the right side of the table with your mouse. you can't see scroll *othe right n,decrease the View Zoom setting for the wnrks»oet. Removing To remove lines that you have added, select the ^'^ button with your mouse. This will delete the last line of the section. You cannot n,muva lines that were not added; an orm, message will appear if you \m |fyou add additional lines with this ethod.the pagination may hoaffected forcing the for 'r ` overmmho,pages. gosure msvbmdall pages m�m op|anomminor.Adding D.ixxee u�dx °Um|(i ` � incidded I in t6e A completed MECH-FANSYS form is requi ed foREWEVEOT 11 M. copy of (his foi6mg WV Oa F4 MECH- workbook. If additional MECH-FANSYS form E(OM: tem Form" Mfg in M[E'CH-FANSYS- ifh FANQfg- It Ro to AUG 0 tcf f!rms are set-up to be printed in letter o7ernat,witA*"lMhe ME H-EQ Cooling & !,�eating Equipment e Form. This MECH-EQ form may ptinted in either or lette, ),rnt, however the font is larger and, - :1andscape easier to read when printed in landscape. PERMIT CENTcERe losing form details when printi g you Q�YaQfaTt*"N printe memory. Try printipq�l:&Ie'm Pages ;no f CORREP TIMelected forms are printed. To select one o trl key and click the tabs of the e ts you need. Issue the File Print Selected Sheets rird th set, use File Print E III COVVN , tl Ab ITRC I Wor V � ^ A lek • Instructions for Electronic Forms 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Forms (worksheets) in a workbook may not be deleted because the file is locked. Clean Forms To print blank forms to fill out by hand, delete all of the heading information at the beginning of MECH-SUM. For each radio button group there is a button labeled "Clear." Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear" button will not print. End of Instructions for Electronic Forms 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Tukwilla Fire Station 51 Date 9/28/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Dept. Use Company Name: Company Address: Applicant Name: Applicant Phone: Project Description Briefly describe mechanical systems in the text box provided 0 New Building 0 Building Addition Ej Tenant Improvement I: System Retrofit E No System Changes • Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. Design Load Calculations El Load calculation summary E] MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules forms are not required, El Mechanical Plans • MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ however, include on plans all applicable compliance information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of a DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no • Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, • Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu 2) 0 DOAS included in project, although not required (occupancy not office, retail, education, • DOAS related allowances included in project: • Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. • Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power E: Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. exceeds 5hp. 5 horsepower threshold. 111 For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems • Hydronic chilled water • Water -loop heat pump 0 No hydronic systems El Hydronic heating water E Geothermal C406 Additional Efficiency Options - Mechanical or air -to -water heat be 15% more efficient than have FEQ a 71 and must be required ventilation air in a annual hot water energy use be • C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must minimum requirements. All stand alone supply, retum, and exhaust fans over 1 hp must selected within 10% of maximum total or static pressure. El C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. El C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of provided by heat pump, waste heat recovery or solar water -heating systems. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, pg. 2 Forms for Commercial Buildings including MECH-SUM R2 & R3 over 3 stories and all R1 Revised January 2017 2015 Washington State Energy Code Compliance Service Water Heating Systems Equipment Type (s) E:1 Instantaneous 0 Heat exchange from space heat boiler or central hot water/steam Ej On -demand water systems El Hot water heating tank(s) • No service 0 Dedicated boiler Distribution Type (s) • Circulation System Commissioning Commissioning is required for. per C408.2 Ej Service water heating systems per C408.4 shall be performed for all applicable systems regardless of individual equipment capacity. requirements: of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h heating. Mechanical systems commissioning not required. water heating system in building does not exceed 200,000 Btu/h. Service water heating not required, El Mechanical systems If required, commissioning Exceptions to commissioning . Total output capacity cooling or 300,000 Btu/h . Capacity of largest service systems commissioning Low Energy and Semi -Heated Spaces (Note 6 and 7 Space Type Location in Plan(s) Space(s) Served Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, MLA (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. En er 0 if no cooling. Note 6 - Refer to Section C402,1.1 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h*sf. Note 7 - Refer to Section C402,1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h"sf Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 20 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type NA C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception NA Yes C403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery Attached Yes C403.2.2 Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater than the smallest available equipment size that exceeds the calculated loads; note exceptions taken Attached Yes C403.2.3 C403.2.3.2 C403.2.13.1 HVAC equipment performance requirements (efficiency)rfOrmanand Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) M003 Yes C405.8 C403.2.14 Electric motor efficiency List all motors >_ 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated efficiency, or exception applied NA NA For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken Yes C403.2.11.1 Fan power limitation For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form See Fansys For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system See Fansys Yes C403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken MO.3 Yes C403.2.11.3 Fan efficiency For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is z 67, or exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency M0.3 NA C403.2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE-57) NA Yes C403.2.13 Variable flow capacity - fans For fan motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements NA NA C403.2.3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is 5 100 tons, or exception taken NA NA C403.4 Large capacity cooling systems For buildings with a 300 tons of cooling capacity, indicate method of multi -stage or variable capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) NA NA C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements NA NA C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with >_ 1,100 gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers NA NA C403.4.2 C403.4.2.5 Large capacity boiler systems For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating burner NA NA For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate turndown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) C403.2.13 Variable flow capacity - pumps For pump motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements NA C403.2.3 Gas and oil -fired forced air furnace and unit heaters For forced air furnaces with capacity z 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss NA NA C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity> 225,000 Btu/h, indicate modulating or staged combustion control NA Yes C403.2.3.3 Packaged electric heating / cooling equipment Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of heating is a heat pump; include in equipment schedules M003 NA C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements NA NA C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements NA Yes C403.2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized, or gravity and exception taken (include leakage rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers M501, M502, M701 NA C403.2.4.3 Retum air dampers Indicate locations of retum air dampers that are integral to economizer operation; verify dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 20 Mechanical Permit Plans Checklist 2015 Washington State Ener �r Commercial Buildings includingR2 R over orie and all R MECH-CHK Revis d nua 20 7 ode o pli nce Fo Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements NA NA C403.2.4.4 Zone isolation dampers For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements NA NA 0403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken NA Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible NA C406.2.1 0403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply NA NA C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% NA NA C406.2.3 C403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand alone fans is 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the maximum total or static efficiency NA HVAC System Controls Yes C403.2.4.1 Thermostatic controls (thermostats and humidistats) Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones M501, M502 __ _ Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones M501, M502 If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating M501, M502 NA C403.2'4'1'1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lock -out temperature set to 40°F or less NA Yes 0403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling NA 0403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans NA NA Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling NA C403.2.4.2 0403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken NA NA 0403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy NA C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust NA 0403.2.4.3 Stairway and shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) NA NA 0403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken NA NA 0403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied NA NA C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F NA NA C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing NA NA 0403.2.4.9 Group R1 hotel / motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 20 Mechanical Permit Plans Checklist MECH-CHK Revised January 2017 hinaton State EneravCode Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and ail R1 - — _ Project Title: Tukwilla Fire Station 51 ,Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.10 C403.2,4.11 Group R2 / R3 dwelling units, Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for at thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken NA Yes C403.2.6 C403.2.11.4 Ventilation Indicate method of ventilation air delivery (natural or mechanical) for each zone M5.1 If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken M5.1 If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces NA NA C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and 1 or the system has airside economizer or automatic modulating OSA damper; indicate OSA controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception NA NA C403.2.6,3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or altemate means provided to automatically reduce OSA when space is partially occupied NA NA C403.2.6.4 C403.2.6.4.1 Enclosed loading dock ventilation For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) NA NA C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken NA NA C403.2.7,1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) NA NA NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements NA Yes C403.2.13 Variable flow capacity - HVAC system fans For HVAC fan motors a 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken NA NA C403.3.1 DX air handler variable cooling control (Under Integrated Economizer) For DX air handlers with economizer and cooling capacity a 65,000 Btu/h, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load NA NA __ _ _ Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) Yes C403.2.11.5 Fan airflow control For DX air handling units with cooling capacity a 65,000 Btu/h and evaporative and chilled water air handling units with fan a 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) NA NA NA For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is 5 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is s 50% of full speed drawing 5 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken C403.2.4.12 DDC system capabilities Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table C403.2.4.12.1 - Identify all DDC system input / output control points; indicate capability for trending and graphical display Ducting Systems Yes C403.2.8.1 C403.2.8.3 Duct construction Indicate on plans that all ductwork is constructed and sealed per IMC M001 ._ ___ _ __ .— For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC M001 Yes C403.2.8,3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M501, M502 NA C403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 8 of 20 Mechanical Permit Plans Checklist MECH-CHK Revised January2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Yes C403.2.8.1 C403.2.8.2 Duct insulation For supply and retum ductwork located in unconditioned space or outdoors, indicate R-value of insulation on ductwork on plans; identify climate zone; note exceptions taken M001 For supply ductwork located in conditioned space, identify if design supply temperature is < 55°F or > 105°F and indicate R-value of insulation on this ductwork on plans; note exception taken M001 M001 For OSA ductwork, shafts and plenums, indicate R-value of insulation on these elements on plans per Table C402.1.3 for steel -framed walls; note exception taken Piping Systems Yes C403.2.9 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken M001 Yes C403.2.9.1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping plans NA Economizers NA C403.3 Air economizer required Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls NA NA Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of air economizer; indicate on plans eligible exception(s) taken and measures to comply with exception(s) NA C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load NA NA C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation NA NA C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100%OSA for cooling NA NA C403.3.1 .3.3. C4032 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F NA NA For systems with cooling capacity Z 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NA C403.3.3.3 Air economizer high limit controls Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 NA NA C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA temperatures NA NA . C403.3.42 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit NA NA C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity Z 65,000 Btu/h, refer to HVAC System Controls for requirements NA NA C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity Z 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults NA Systems Requiring Energy Recovery NA C403.5.1 Energy recovery (ER) - ventilation / exhaust systems For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations NA NA For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by z 50% based on delta between OSA and return air enthalpies at design conditions NA NA C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to pre -condition laboratory make-up air; ER effectiveness (min 25°F); or altemative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) NA NA C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken NA NA Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by z 36°F NA C403.5'2 Energy recovery - steam condensate systems For buildings with on -site steam heating systems, indicate condensate water ER NA For buildings that use off -site generated steam where condensate is not retumed to the source, indicate on -site condensate water ER NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 9 of 20 Mechanical Permit Plans Checklist MECH-CHK Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in documents Location in Building Department (yes,no,na) permit Documents Notes For buildings with food service, meat or deli departments that have 2 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) NA C403.5.3 Energy recovery - cooler / freezer condensers NA For buildings with 2 40,000 sf conditioned floor area and with 2 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating NA For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and NA C403.5.4 Energy recovery - condenser systems design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). NA Hydronic System Controls For hydronic system pump motors 2 7.5 hp, indicate method of variable flow control (VSD or C403.2.13 Variable flow control - equivalent method that requires 2 30% design wattage at 50% design fluid flow); note C403.4.2.7 hydronic system pumps exception taken NA Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) NA For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature NA For heating and chilled water systems 2 300,000 Btu/h, indicate systems are configured to C403.2.5 Hydronic system setback automatically reset supply water temperature based upon demand; or exception taken. C403.4.2.4 and part load controls If system pump motor hp 2 3 hp, also indicate controls automatically reduce flow by 2 50%.NA For chilled water systems (2 300,000 Btu/h, pump motor hp 2 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open, or to maintain a minimum differential pressure; or exception taken NA C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers NA C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 NA NA C403.4.2.2 Two -pipe changeover systems Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and changeover temperature range (limit 30°F) NA C403.4.2.6 Chiller / boiler plant pump isolation Indicate controls are configured to automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use For cooling towers with fan motors 2 7.5 hp, indicate VSD and method to adjust fan speed C403.2.13.1.1 (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat NA C403.4.3.1.1 Heat rejection equipment flow rejection device) NA C403.4.3.1.2 variable control For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison NA NA C403.4.3.3 Heat rejection equipment - cooling tower flow tumdown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel NA NA C403.4.2.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken NA Water loop heat pump - Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method NA C403.4.2.3.21 heat rejection equipment, Zone 4 used to limit system heat loss when heat rejection is not needed NA Water loop heat pump - For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling NA C403.4.2.3.2.2 heat rejection equipment, Zone 5 tower and heat pump loop NA NA C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power> 10 hp, indicate 2-way isolation valves on each heat pump and variable flow system control NA Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 For buildings with office, retail, education, library and fire station spaces, identify these spaces NA C403.6 C403.6.3 Dedicated outdoor air systems on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1 „4 or C406.6 may not utilize exceptions) M501, M502 Energy recovery ventilat on For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting NA C403.6.1 with DOAS calculations. Indicate ER rated effectiveness that increases OSA enthalpy by 2 50 /o based on delta between OSA and return air enthalpies at design conditions. M002 Heating / cooling system Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is NA C403.6.2 controls with DOAS configured to turn down, when there is no call for heating or cooling in the zone they serve M002 If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 10 of 20 Mechanical Permit Plans Checklist MECH-CHK Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 NA Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) NA C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 M802 Multiple Zone Air Systems NA C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV NA NA C403.4.4 VAV systems serving multiple zones Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and types _ _ NA NA For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans NA C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling NA NA C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct NA NA C403.4.1.1 C403.4.1.2 VAV system static pressure sensors - sensors and DDC set points Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is <_ 1.2 inch w.g. NA NA For systems with zone level DDC, indicate controls are configured to monitor zone damper positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic NA C403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken NA NA C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken NA Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions NA C403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with all related economizer requirements per C403.3 (without economizer exceptions) NA NA C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display NA NA C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) NA NA C403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions NA NA C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 NA NA C403.7, Item 6 Interior / exterior zone design supply air temperature Verify that VAV terminals serving interior cooling driven loads are sized per design supply air temperature that is 5°F higher than VAV terminals serving exterior zones NA NA C403.7, Item 7 Maximum air terminal inlet velocity identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EO form; indicate air terminal inlet velocity does not exceed 900 fpm NA NA C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 NA NA C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is 590% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system NA NA C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; indicate DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating, low cooling, or ventilation only is 5 66% of peak design air flow or provide supporting documentation for applied exception NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 11 of 20 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.7, Item 11 Application of single duct unitsanterminal Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units NA NA NA C4D3.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction NA NA C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density 2 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by a 5°F NA NA C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 NA NA C403.7, Item 15 Central plant efficiency Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant NA NA If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas -fired boiler(s) with thermal efficiency > 90%, air -to -water heat pumps, or heat recovery chillers — - - -- — . -- If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25°/0 per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is 5 20% of total plant capacity, or provide thermal storage sized for <_ 20% of total plant capacity NA NA C403.7, Item 16 Fault detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system NA HVAC Equipment Energy Use Metering Yes C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception NA Documentation and System Specific Requirement To Support Commissioning Yes C406.2 Scope of mechanical systems commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; M00' For buildings with z 240,000 Btu/h total output cooling capacity or z 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception M001 Yes C403.2.10 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; M001 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); M001 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. M001 Yes C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a mariner to first minimize throttling losses, then adjusted to meet design flow conditions M001 Yes C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing M001 Yes C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps M001 Yes C408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M001 Project Close Out Documentation Yes C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations M001 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 12 of 20 Service Water Heating Permit Plans Checklist SWH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January2017 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type Yes 0404.2 SWH equipment type and efficiency Provide equipment schedule on plans indicating type and capacity; indicate efficiency complies with required federal standard MO.2 NA C404.2.1 High input -rated SWH systems For individual SWH equipment serving an entire building with 1,000,000 Btu/h capacity, indicate thermal efficiency 90%; or exception taken NA For buildings with aggregate capacity of all SHW equipment ..? 1,000,000 Btu/h (exclude < 100,000 Btulh equipment from threshold calculation), indicate average capacity weighted thermal efficiency 90%; or exception taken NA If applying Exception 1 for site -solar or site -recovered energy, provide calculations and source of annual service water heating energy use estimate NA C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply and discharge Spec C404.5 Insulation under electric water heater For electric water heaters located in unconditioned spaces or on concrete floors, indicate R-10 insulation under equipment Spec Piping Systems Yes 0404.6 Insulation of piping Indicate thickness of piping insulation on plans per Table 0403.2.9; verify insulation is provided - from the water heater to the final fixture in a line, from the inlet / outlet piping at water heater to heat trap (up to 8 feet), and on piping that is heat traced; note exceptions taken MO.1 NA 0404.3 Efficient SWH supply piping Indicate method of compliance on plans for all piping runs connecting service hot water source to hot water fixture (maximum pipe length or maximum pipe volume method per Table C404.3.1); provide calculations for all piping runs documenting the total length and / or volume NA Service Water Heating System Controls Yes C404.7.1 0404.8 Heated -water circulating systems For circulation systems with dedicated return piping, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand and when the desired water temperature is met — - Spec Spec For circulation systems with cold water supply piping serving as the return, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand, or when temperature of water entering the cold water supply pipe is 104°F NA 0404.7.2 Heat trace system controls For heat trace systems provided to maintain temperature of service hot water in piping, indicate controls are configured to de -energize system when there is no demand for hot water and when the desired water temperature is met NA NA 0404,7.3 Controls for hot water storage For systems with separate water heater and storage tank, indicate controls are configured to limit operation time of pump after end of heating cycle to 5 5 minutes NA NA C403.2.13 C403.4.2.7 Variable flow control - pumps For SWH, pool / spa and pressure boosting pump motors 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires 30% design wattage at 50% design fluid flow); note exception taken NA NA Identify basis of pump speed control (differential or static pressure setpoint, pressure, zone load demand, etc) Pools and Permanent Spas - Equipment and Controls (Sections are under C404.11) NA C404.10.1 Pool heating equipment efficiency Provide equipment schedule on plans indicating type and capacity for all pool heating equipment; indicate efficiency complies with required federal standard; for heat pump water heaters indicate COP 4 NA NA 0403.2.13 Variable flow control - pumps Refer to Service Water Heating System Controls NA NA C404.10.1 C404.10.2 Pool heater on / off controls Indicate automatic on / off control based on scheduling and readily accessible on / off switch on heater that operates independent of thermostat setting; note exceptions taken NA NA 0404.10.3 Pool covers For all pools and in -ground permanent spas, indicate a vapor retardant cover on plans For all pools and in -ground spas heated to > 90°F, indicate cover shall include insulation R- 12 NA NA NA 0404.10.3 Pool assembly insulation For all pools and in -ground spas heated to > 90°F, Indicate on plans that sides and bottom are provided with insulation a R-12 NA NA 0404.12 Energy consumption of portable spas Indicate portable spa complies with Association of Pool and Spa Professionals APSP-14 NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 13 of 20 Energy Recovery (ER) Systems - Service Water Heating and Pool Systems NA C404.10.4 (Section under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or permanent spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken NA NA — — Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by a 36°F NA C403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have a 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water For buildings with a 40,000 sf conditioned floor area and with >_ 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water NA NA NA C403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and > 1,500,000 Btu/h of heat rejection capacity and design SWH load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). NA NA C404.10 Drain water heat recovery units For systems incorporating drain water ER, indicate system design complies with CSA B55.2 (or CSA 55.1 for Group R); indicate potable waterside pressure loss at design flow is < 10 psi NA Service Water Heating Energy Use Metering NA G404.9 SWH energy usage in dwelling units For Group R-2 multi -family buildings with central SWH systems, provide metering of hot water energy usage per dwelling unit; indicate metering and data reporting method NA NA C409.3.2 SWH equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, with total SWH equipment capacity a 50 kW ( a 170,600 Btu/h), verfiy energy use metering of all SWH equipment will be provided per C409 NA Additional Efficiency Package Option, Reduced Energy Use In Service Water Heating - Must comply with both provisions to be eligible NA C406.7.1 Eligible building type To comply with additional efficiency package option, verify that a 90% of the conditioned floor area of the building is one or more of the occupancies identified in this section, OR; NA NA — Provide whole building energy analysis per C407 that demonstrates the SWH load in the building is a 10% of total building energy loads NA C406.7.2 C403.5.4 Load fraction To comply with additional efficiency package option, provide documentation that verifies >_ 60% of building annual SWH energy is provided by high efficiency sources (heat pump water heater with COP a 3, waste heat recovery, solar water -heating system); NA NA For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h (per C403.5.4); provide documentation that verifies a 100% of building annual SWH energy is provided by condenser energy recovery or other high efficiency source Documentation and Specific System Requirements to Supporting Commissioning Yes C408.4 Scope of service water heating systems commissioning Indicate that all SWH equipment and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned;+D7 Spec Spec - ._. _ .. _ __._ . For buildings where the largest SWH system has ? 200,000 Btu/h total output capacity, indicate that all SWH systems regardless of individual capacity are required to be commissioned. NA C408.4.1.3 Scope of pool and permanent spa systems commissioning Indicate that all pool and permanent spa water heating systems regardless of individual capacity are required to be commissioned; NA NA NA Indicate that energy recovery equipment that heats pool water regardless of capacity is required to be commissioned; Identify all pool heating and energy recovery equipment and controls that the WSEC defines as being capable of and / or configured to perform specific functions. Yes C404.13 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable service water heating systems; MO.2 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activites, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); -_ — - --- - MO.1 M001 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. Yes C408.4.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M002, M003 Project Close Out Documentation Yes C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all SWH components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations M001 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & Project Title: Tukwilla Fire Station 51 R3 over 3 stories and all R1 Revised January 2017 Date 9/28/2018 All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available, Identify all systems that an economizer exception will be applied to and additional information as noted below. For Building Dept. Use Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year- round design cooling loads from lights and equipment less than 5 watts per square foot. System ID Lighting + Equipment Loads (W/sf) Exp 2 Single zone unitary or package systems with dehumidification that affect other systems such that air economizer would increase energy consumption. System ID Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. System ID Exp 4 Equipment that provides hydronic chilled water for chilled beams and chilled ceiling systems that is served by a water economizer system per C403.3.4 in lieu of air economizer. System ID Exp 5 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Exp 6 Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System 110 Equipment Location Cooling Capacity (Btu/h) Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor unit shall be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System ID Cooling Capacity (Btu/h) VRF 228,000 Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied heat pumps. System ID SEER, EER, & IEER Exp 9 Cooling equipment with energy recovery. Spaces served shall have year-round design cooling loads from lights and equipment greater than 5 watts per square foot. Energy recovery system shall utilize recovered energy for on -site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of recovered energy used for on -site heating purposes is equivalent to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Lighting + Equipment Loads (W/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stones and all R1 Economizer Exceptions, cont. ME04-1-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Date 9/28/2018 Economizer Exception Summary Refer to Section C403,3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED Exp 10 Cooling equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit for this exception is 240,000 Btu/h cooling capacity or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a - Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency.. Option b - Waterside economizer required. Cooling equipment efficiency shall be 5% better than the WSEC required minimum efficiency. Option c- Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127, System ID Compliance Option Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 240 kBtu/h): Alternate Exp 10 Capacity Limit: ECONOMIZER EXCEPTIONS - MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT C503.4 Exp 1 Pre -approved design alternative to full compliance with air economizer requirement. An alternative for mechanical system alterations where existing building constraints make full compliance with air economizer requirement impractical. Provide calculations to the code official that demonstrate the proposed alternate design strategy provides similar energy savings to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Alt. Strategy ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h, Per Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5% of required building air economizer capacity, whichever is greater. Cooling equipment efficiency shall be 15% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement, System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 72,000 Btu/h): Alternate C503.4 Exp 2 Capacity Limit: C503.4 Equipment that provides hydronic chilled water for chilled water terminal Exp 3 units. Equipment part load cooling efficiency (IPLV) shall be better than WSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the building capacity total. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 480,000 Btu/h): Alternate C503.4 Exp 3 Capacity Limit: Table Compliance Options for alteration or replacement of existing C503.4 mechanical cooling equipment per Table C503.4. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Any new or replacement equipment Option b - Replacement equipment of same type with same or smaller cooling output capacity. Option c - Replacement equipment of same type with large cooling output capacity. Option d - New equipment added to existing system or replacement equipment that is different than existing being replaced. System ID Equipment Type Compliance Path 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 2015 Washington State EnergyCode Compliance Forms for Commercial Buildings includingR2 & R3 over 3 stories and all R1 Revised January2017 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RHRV CV Rootop Heat Recovery Unit 4.6 No Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals, VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 A separate MECH-FANSYS form must be completed far every HVAC system that exceeds the 5 hp threshold. For Building Dept. Use Fan System ID System Supply Fan y pp y Speed Control CV Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1, Exception 1 COm liance O tion p p Brake HP Compliance is based upon either the fan motor nameplate horse power (Option 1), the fan brake horsepower (Option 2), or C403.7 high efficieny VAV fan brake horsepower (10% less than Option 2). The bhp calculation provides adjustments for special equipment per Table C403.2.11.1(2). Fan System Supply y pp y CFM Total 1,900 In Fan Equipment Schedule below, provide maximum design supply airflow rate (CFM) of all supply fans serving the conditioned space in Fan Equipment Schedule below. Fan System CFM Total is the supply airflow of the central air handler at peak design conditions. Additional volumetric air flow provided at zone fan terminals, booster fans, or through induction is not included in the supply CFM total. However, the fan power of this equipment is included in the HP and BHP calculations. Fan System Supply CFM Total is automatically calculated by the form. Fan Equipment Schedule Fan ID and Location Fan Type Quantity of Fan Type Total CFM (Note 1) Total Nameplate HP (Note 2) Total BHP (Note 3) Supply 1 1,900 2 1.4 Exhaust 1 1,900 2 1.3 Note 1 - Total CFM is the maximum CFM of the listed fan(s) when operating at peak design operating conditions. Note 2 - Total namplate hp of the listed fan(s). Note 3 - Total brake horsepower (bhp) of the listed fan(s) at peak design operating conditions. Not required if Nameplate HP compliance option chosen. Compliance Message: Total Proposed: p Total Allowance: 4.0 2.7 2.1 2.8 COMPLIES Brake Horsepower Allowance Adjustments Device Type Description and Location CFM thorough this device (CFMD) Assigned Pressure Drop, PD in w.c. (Note 6) Calculated Pressure Drap, PD in w.c. (Note 7) Adjustment, A in bhp (Note 8) Fully ducted return and/or exhaust Exhaust Ductwork 1,900 0.5 0.230 Particulate filtration: MERV 13 - 15 Supply Fan 1,900 0.9 0.414 Energy recovery device, other than coil (Notes 4 & 5) Energy Wheel 1,900 0.8 0.368 Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): ..{........... .. {L... rcAAr !.. {{... .........F {L.....,,...,I,. /'I AA ....d .... L.... ...rC0A (t L...4L...... LL........L. 1.01 the device. Note 5 - Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply divided by the enthaply difference between the outdoor air and return air at design conditions. Note 6 Assigned pressure drop (PD) adjustment per Table C403.2.11.1(2). Note 7 - Pressure drop (PD) adjustment shall be calculated per the applicable method defined in Table C403.2.11.1(2) based on specific system conditions. Note 8 - A = PD * CFMD/4131 where A is the allowed system brake horse power adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 General Instructions: A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system. Enter CFM and brake horsepower (bhp) of each fan at peak design conditions and the nameplate horsepower (hp). Include supply, return and relief fans, exhaust and exhaust hood fans (>1 hp), booster fans and fans included as part of make-up air units, dedicated outside air systems (DOAS), energy recovery ventilators (ERV), and series fan -powered terminal equipment. B. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. C. Fans not directly associated with the delivery and removal of conditioned air, such as condenser fans, do not need to be included in the fan power total. D. Fan power calculations are not required for non -central air HVAC systems such as 4-pipe fan coils and variable refrigerant flow (VRF) systems unless individual fan systems are greater than 5hp. E. In the Brake Horsepower Allowance Adjustments table, if a Device Type is selected that has an Assigned Pressure Drop, this value will autofill into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write -protected. If the Device Type requires a Calculated Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write -protected. F. Refer to FAQ section of MECH-FANSYS-DOC for additional instructions. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 .Fan Power Allowance Adjustment Factors 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH-FANSYS-DOC Revised January 2017 TABLE C403.2.11.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT Device Adjustment Credits Fully ducted return and/or exhaust air systems 0.5 inch w.c. (2.15 inches w.c. for laboratory and vivarium systems) Return and/or exhaust air flow control devices 0.5 inch w.c. Exhaust filters, scrubbers, or other exhaust treatment The pressure drop of device calculated at fan system design condition Particulate filtration credit: MERV 9 - 12 0.5 inch w.c. Particulate filtration credit: MERV 13 - 15 0.9 inch w.c. Particulate filtration credit: MERV 16 and greater and electronically enhanced filters Pressure drop calculated at 2x clean filter pressure drop at fan system design condition Carbon and other gas -phase air cleaners Clean filter pressure drop at fan system design condition Biosafety cabinet Pressure drop of device at fan system design condition Energy recovery device, other than coil runaround loop (2.2 x energy recovery effectiveness) — 0.5 inch w.c. for each airstream Coil runaround loop 0.6 inch w.c. for each airstream Evaporative humidifier/cooler in series with another cooling coil Pressure drop of device at fan system design conditions Sound attenuation section (fans serving spaces with design background noise goals below NC35) 0.15 inch w.c. Exhaust system serving fume hoods 0.35 inch w.c. Laboratory and vivarium exhaust systems in high-rise buildings 0.25 inch w.c./100 feet of vertical duct exceeding 75 feet Deductions Systems without central cooling device -0.5 inch w.c. Systems without central heating device -0.3 inch w.c. Systems with central electric resistance heat -0.2 inch w.c. w.c..= water column. For SI: 1 inch w.c..= 249 Pa, 1 inch.= 25.4 inm. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Design 2015 Washington Load Calculation Summary MECH-LOAD-CALC State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all FeRevised January 2017 Project Title: Tukwilla Fire Station 51 Date 9/28/2018 The following information shall be included in the load calculation program summary submitted with the permit documents. If a load calculation summary is not available, provide the required information below. For Building Dept. Use Equip. ID Area(s) Served Heating Design Load in Btu/h (Note 1) Cooling Design Load in Btu/h (Note 1) Calculation Method (Note 2) Notes See Attached HAP Program Output. Note 1 - Design load shall account for the building envelope, lighting, ventilation and occupancy loads of the space(s) served by the mechanical system. Heating and cooling loads .shall be adjusted to account for load reduction achieved by an energy recovery system, if applicable. Note 2 - Computer load calculation program, worksheet (identify source), or equivalent computation procedure in accordance with ASHRAE Standard 183. vfr...solt...4- nidyA-no 1.0.44) Air System Design Load Summary for ZONE 01-STORAGE Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB 1 WI3 23.0 *F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' - - 0 ft - - Wall Transmission - - 358 ft2 . 495 - Roof Transmission 0 ft2 - - 0 fe _ Window Transmission 0 ft' - - 0 ft' 0 - Skylight Transmission 0 ft2 - - 0 ft2 0 - Door Loads 2 0 ft- • 0 ft20 - Floor Transmission 187 ft' - - 187 f12 244 - Partitions 0 ft2 - - 0 ft2 0 - Ceiling 0 ft" - - 0 ft' 0 - Overhead Lighting - - _ 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - - 0 0 0 Infiltration - - - _ 0 0 Miscellaneous - - - 0 0 Safety Factor 0% / 0% - - 0% 0 » Total Zone Loads - - 739 0 Zone Conditioning - - - - 692 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Retum Fan Load - - - 35 CFM 0 - Ventilation Load - - - 22 CFM 970 0 Supply Fan Load - - - 35 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - >> Total System Loads - - - - 1662 0 Central Heating Coil -- - - 1662 - >> Total Conditioning - - - - 1662 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 8 2019 City of Tukwila BUILDING DIVISION Hourly Analysis Program v4.91 CORRECTION LTRO I RECEIVED CITY OF TUKWILA AUG 0 1 2019 PERMIT CENTER Page 1 of 18 Air System Design Load Summary for ZONE 02-SCBA Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB 1 WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTUIhr) Details Sensible (BTU/hr) Latent (BTU1hr) Window & Skylight Solar Loads 0 ft' - - 0 ft' - - Wall Transmission 303 ft' - - 303 2 419 - Roof Transmission 0 ft2 - - 0 ft 0 Window Transmission 0 ft - - 0 ft' 0 : Skylight Transmission 0 ft' - - 0 ft' 0 - Door Loads 21 ft' - - 21 ft' 326 . Floor Transmission 436 ft2 - - 436 ft' 399 - Partitions 0 ft' - - 0 ft' 0 - Ceiling 0 fI '0 - - ft20 " . _ Overhead Lighting - - - o o - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - . 0 0 0 Infiltration - - - - 0 Miscellaneous - - - . 0 0 Safety Factor 0% / 0% - - 0% 0 0 » Total Zone Loads - - - - 1144 Zone Conditioning - - - - 1300 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 310 CFM 0 - Ventilation Load - - - 310 CFM 13810 Supply Fan Load - - - 310 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - » Total System Loads - - - - 15110 Central Heating Coil - - - • 15110 - » Total Conditioning - - - - 15110 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 2 of 8 Air System Design Load Summary for ZONE 03-SHOP Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 - - 0 ft' - - Wall Transmission 216 ft2 - _ 216 ft 298 Roof Transmission 0 ft' - - 0 ft' 0 i Window Transmission 0 ft2 - - 0 ft2 0 - Skylight Transmission 0 ft' - - 0 ft2 0 - Door Loads 0 ft2 - - 0 ft' 0 - Floor Transmission 216 ft2 - - 216 ft' 224 - Partitions 0 ft2 - - 0 ft' 0 '. Ceiling 0 ft2 - - 0 ft2 0 - Overhead Lighting - - . 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0- People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 » Total Zone Loads - - - - 522 0 Zone Conditioning - - - - 595 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 250 CFM 0 - Ventilation Load - - - 250 CFM 11150 0 Supply Fan Load - - 250 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - 0% 0 - » Total System Loads - - - - 11745 0 Central Heating Coil - - - - 11745 _ » Total Conditioning - - - - 11745 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 3 of 18 Air System Design Load Summary for ZONE 04-MECH Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 0 ft' - - 0 ft' - - Wall Transmission 440 ft2 - - 440 ft 608 - Roof Transmission 0 ft' - - ft0 ' - Window Transmission 0 ft2 .. - 0 ft' 0 Skylight Transmission 0 ft2 - - 0 ft2 0 ' Door Loads 21 ft2 - - 21 ft' 326 - Floor Transmission 216 ft' - - 216 ft2 290 - Partitions 0 ft' - - 0 ft' 0 - Ceiling 0 fl' - - 0 ft' 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 » Total Zone Loads - - - - 1224 0 Zone Conditioning - - - - 1259 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 200 CFM 0 - Ventilation Load - - - 200 CFM 8862 0 Supply Fan Load - - - 200 CFM 0 Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - >> Total System Loads - - - - 10121 0 Central Heating Coil - - - - 10121 . » Total Conditioning - • - - 10121 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 4 of 18 Air System Design Load Summary for ZONE 05-APP BAY Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 2078 ft - - 2078 ft' - - Wall Transmission 201 ft' - - 201 ft' 277 - Roof Transmission 3558 ft' - - 3558 ft' 3932 Window Transmission 2078 ft' - - 2078 ft2 30521 : Skylight Transmission 0 ft' - - 0 ft' 0 - Door Loads 805 ft' - - 805 ft' 9330 _ Floor Transmission 3558 ft' - - 3558 ft' 2038 - Partitions 0 ft' - - 0 ft' 0 - Ceiling 0 ft' - - 0 ft' 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 _ Electric Equipment - - - 0 0 .. People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous _ - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 » Total Zone Loads - - - - 46099 0 Zone Conditioning - - - - 45118 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - -0 0 - Retum Fan Load - - - 3700 CFM 0 - Ventilation Load - - - 3700 CFM 162081 0 Supply Fan Load - - - 3700 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 00/0 - - 0% 0 - >> Total System Loads - - - - 207199 0 Central Heating Coil - - - - 207199 - » Total Conditioning - - - - 207199 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 5 of 18 Air System Design Load Summary for ZONE 06-GEAR STORAGE Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 0 ft2 0 0 ft' - Wall Transmission 159 ft' 233 159 ft' 256 Roof Transmission 1088 ft2 1607 - 1088 ft' 1403 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 28 ft' 59 - 28 ft' 508 - Floor Transmission 1088 ft' 0 - 1088 ft' 575 Partitions 0 ft' 0 0 ft' 0 - Ceiling 0 ft2 0 - 0 ft' 0 - Overhead Lighting 544 W 1856 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 6 3150 5550 0 0 0 Infiltration - 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6905 5550 - 2742 0 Zone Conditioning - 7045 5550 2851 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 0 0 - Return Fan Load 1500 CFM 0 - 1500 CFM 0 - Ventilation Load 1500 CFM 13964 -5550 1500 CFM 77971 0 Supply Fan Load 1500 CFM 0 1500 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 21009 0 - 80822 0 Central Cooling Coil - 21009 0 - 0 0 Central Heating Coil - 0 - - 80822 » Total Conditioning - 21009 0 - 80822 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg Toads Negative values are clg loads Hourly Analysis Program v4.91 Page 6 of 18 Air System Design Load Summary for ZONE 07-RECE1VING Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB I WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft 0 - 0 2 - _ Wall Transmission 65 ft' 96 - 65 f12 105 - Roof Transmission 125 ft' 209 - 125 ft' 161 - Window Transmission 0 ft' 0 - 0 ft2 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 28 ft2 59 - 28 ft' 508 - Floor Transmission 125 ft 0 • 125 ft' 134 - Partitions 0 fl' 0 - 0 ft' 0 - Ceiling 0 ft2 0 - 0 ft" 0 - Overhead Lighting 94 W 320 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 1 295 455 0 0 0 Infiltration • 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 979 455 - 908 0 Zone Conditioning - 933 455 - 867 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 • 0 0 - Return Fan Load 66 CFM 0 - 66 CFM 0 - Ventilation Load 15 CFM 129 -330 15 CFM 759 0 Supply Fan Load 66 CFM 0 - 66 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads • 1062 125 - 1626 0 Central Cooling Coil - 1062 125 - 0 0 Central Heating Coil - 0 - - 1626 . >> Total Conditioning - 1062 125 - 1626 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 7 of 18 Air System Design Load Summary for ZONE 08-BUNK R121 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 82.2 °F / 64.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 12 ft2 524 - 12 ft2 - - Wall Transmission 96 ft' 195 - 96 ft2 155 - Roof Transmission 86 ft2 111 - 86 ft 111 - Window Transmission 12 ft' 6 - 12 ft2 76 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft' 0 - 0 ft2 0 . Floor Transmission 86 ft2 0 - 86 ft' 114 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 60 W 205 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 1 230 120 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads • 1272 120 • 456 0 Zone Conditioning - 1245 120 - 4 7 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 66 CFM 0 - 66 CFM 0 - Ventilation Load 30 CFM 162 -120 30 CFM 1540 0 Supply Fan Load 66 CFM 0 - 66 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 1407 0 - 1977 0 Central Cooling Coil - 1407 0 - 0 0 Central Heating Coil - 0 - - 1977 _ >> Total Conditioning - 1407 0 • 1977 0 Key: Positive values are cig loads Negative values are htg loads Positive values are htg loads Negative values are cig loads Hourly Analysis Program v4.91 Page 8 of 18 Air System Design Load Summary for ZONE 09-BUNK R120 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB / WB 83.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window Skylight Solar Loads 12 ft2 497 - 12 ft2 - - Wall Transmission 207 ft2 237 - 207 ft2 334 - Roof Transmission 90 ft2 138 - 90 ft2 116 - Window Transmission 12 ft2 7 - 12 flz 76 - Skylight Transmission 0 ft2 0 - 0 ft' 0 - Door Loads 0 ft2 0 • 0 ft2 0 - Floor Transmission 90 ft2 0 - 90 ft2 146 - Partitions 0 ft2 0 - 0 ft2 0 _ Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 63 W 215 - 0 0 - Task Lighting 0 W 0 .. 0 0 - Electric Equipment 0 W 0 - 0 0 - People 1 230 120 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 1324 120 - 672 0 Zone Conditioning - 1275 120 - 656 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 71 CFM 0 - 71 CFM 0 - Ventilation Load 30 CFM 204 -120 30 CFM 1535 0 Supply Fan Load 71 CFM 0 - 71 CFM 0 - Space Fan Coil Fans - 0 - • 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 1479 0 - 2190 0 Central Cooling Coil - 1479 0 - 0 0 CentralHeating Coil - 0 - . 2190 - >> Total Conditioning • 1479 0 - 2190 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 9 of 18 Air System Design Load Summary for ZONE 10-CORE Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads ore 0 - 0 ft - - Wall Transmission 119 ft' 78 - 119 ft' 245 . Roof Transmission 1134 ft' 1896 - 1134 ft' 1462 - Window Transmission 0 7 0 - . 0 te 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 21 ft' 44 - 21 ft' 381 - Floor Trans ission 1134 ft2 0 - 1134 ft' 433 - Partitions 0 ft2 0 - 0 ft2 0 _ Ceiling 0 fl2 0 - 0 ft 0 - Overhead Lighting 794 W 2708 - 0 0 - Task Lighting 0 W 0 • 0 0 . Electric Equipment 0 W 0 - 0 0 - People 6 1680 1620 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6407 1620 - 2521 0 Zone Conditioning - 6035 1620 - 2667 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - D 0 - Return Fan Load 550 CFM 0 - 550 CFM 0 - Ventilation Load 550 CFM 4811 -1620 550 CFM 28431 0 Supply Fan Load 550 CFM 0 - 550 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 10846 0 - 31098 0 Central Cooling Coil - 10846 0 - 0 0 Central Heating Coil - 0 - - 31098 - >> Total Conditioning - 10846 0 - 31098 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 10 of 18 Air System Design Load Summary for ZONE 11-BUNK R118 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 84.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window 8. Skylight Solar Loads 14 ft2 164 - 14 ft' - - Wall Transmission 94 ft2 48 • 94 ft2 151 - Roof Transmission 83 ft2 141 - 83 ft2 107 - Window Transmission 14 ft' 9 - 14 ft 89 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 0 ft2 0 - 0 ft' 0 - Floor Transmission 83 ft' 0 - 83 ft' 110 - Partitions 0 ft" 0 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 58 W 198 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 1 230 120 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 790 120 - 458 0 Zone Conditioning - 749 120 - 435 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 41 CFM 0 - 41 CFM 0 - Ventilation Load 10 CFM 71 -98 10 CFM 508 0 Supply Fan Load 41 CFM 0 - 41 CFM 0- Space Fan Cod Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 820 22 - 943 0 Central Cooling Coil - 820 22 - 0 0 Central Heating Coil - 0 - - 943 . >> Total Conditioning - 820 22 - 943 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 11 of 18 Air System Design Load Summary for ZONE 12-BUNK R116 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 84.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU(hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 14 ft 164 - 14 ft2 Wall Transmission 94 ft' 48 - 94 ' 51 Roof Transmission 83 ft' 141 - 83 ft2 107 Window Transmission 14 ft2 9 - 14 t2 89 Skylight Transmission 0 ft' 0 - 0 ft2 0 Door Loads 0 ft2 0 - 0 ft Floor Transmission 83 2 0 83 '110 Partitions 0 ft2 0 0 ft7 0 Ceiling 0 ft' 0 0 ft2 0 Overhead Lighting 58 W 198 0 0 Task Lighting 0 W 0 0 0 Electric Equipment 0 W 0 - 0 0 People 1 230 120 0 0 Infiltration 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 790 120 - 4 8 0 Zone Conditioning 749 120 435 Plenum Wall Load 0% 0 - 0 0 Plenum Roof Load 0% 0 0 0 Plenum Lighting Load 0% 0 0 0 Return Fan Load 41 CFM 0 - 41 CFM 0 Ventilation Load 10 CFM 71 - 8 10 CFM 508 Supply Fan Load 41 CFM 0 - 41 CFM Space Fan Coil Fans 0 - 0 Duct Heat Gain / Loss 0% 0 - 0% 0 >> Total System Loads 820 22 - 943 Central Cooling Coil 820 22 0 Central Heating Coil 0 - 943 - >> Total Conditioning 820 22 - 943 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 12 of 18 Air System Design Load Summary for ZONE 13-BUNK R114 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 84.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window Skylight Solar Loads 14 ft' 164 - 14 ft2 - - Wall Transmission 94 f12 48 - 94 ft 151 - Roof Transmission 83 ft' 141 - 83 ft' 107 Window Transmission 14 ft2 9 - 14 ft' 89 - Skylight Transmission 0 ft2 0 - 0 ft' 0 _ Door Loads 0 ft2 0 - 0 fe 0 - Floor Transmission 83 ft2 0 - 83 tV 1 1 0 - Partitions 0 ft2 0 - 0 fr 0 - Ceiling 0 ft2 0 - 0 ft' 0 - Overhead Lighting 58 W 198 - 0 0 - Task Lighting 0 W 0 • 0 0 - EIectrc Equipment 0 W 0 -- 0 0 . People 1 230 120 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 • 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads • 790 120 - 458 0 Zone Conditioning - 749 120 - 435 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 .. 0 0- Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 41 CFM 0 - 41 CFM 0 • Ventilation Load 10 CFM 71 • 8 10 CFM 508 0 Supply Fan Load 41 CFM 0 - 41 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 820 22 - 943 0 Central Cooling Coil - 820 22 - 0 0 Central Heating Coil - 0 - - 943 - >> Total Conditioning - 820 22 - 943 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 13 of 18 Air System Design Load Summary for ZONE 14-BUNK R112 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 84.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 14 ft' 164 • 14 ft - - Wall Transmission 94 ft' 48 _ 94 ft' 151 - Roof Transmission 83 ft2 141 - 83 ft' 107 - Window Transmission 14 ft' 9 - 14 ft' 89 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 0 ft' 0 - 0 ft' 0 Floor Transmission 83 ft' 0 - 83 ft' 110 - Partitions 0 ft2 0 - 0 ft2 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 58 W 198 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 1 230 120 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safely Factor 0% / 0% 0 0 0% 0 » Total Zone Loads - 790 120 - 458 0 Zone Conditioning - 749 120 - 435 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0_0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 41 CFM 0 - 41 CFM 0 - Ventilation Load 10 CFM 71 -98 10 CFM 508 0 Supply Fan Load 41 CFM 0 - 41 CFM 0 - Space Fan Coil Fans - 0 - - 0 Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 820 22 • 943 0 Central Cooling Coil - 820 22 - 0 0 Central Heating Coil - 0 - - 943 - >> Total Conditioning - 820 22 • 943 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 14 of 18 Air System Design Load Summary for ZONE 15-STATION OFFICE R107 Project Name: 2017,092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTUIhr) Latent (BTUIhr) Window & Skylight Solar Loads 51 ft2 1350 51 ft' - - Wall Transmission 471 ft' 512 - 471 ft2 1141 - Roof Transmission 944ft2 1579 - 944 ft 1217 - Window Transmission 51 ft2 38 - 51 ft2 325 - Skylight Transmission 0 ft2 0 - 0 ft' 0 - Door Loads 32 ft' 73 - 32 ft' 627 - Floor Transmission 944 ft' 0 - ft2944 902 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft' 0 - Overhead Lighting 661 W 2255 .. 0 0 - Task Lighting 0 W 0 - 0 0 . Electric Equipment 0 W 0 - 0 0 - People 8 1960 1640 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 7766 1640 - 4212 Zone Conditioning - 7439 1640 - 4329 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 436 CFM 0 - 436 CFM 0 - Ventilation Load 200 CFM 1629 -1640 200 CFM 10240 0 Supply Fan Load 436 CFM 0 - 436 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 9068 0 - 14569 0 Central Cooling Coil - 9068 0 • 0 0 Central Heating Coil - 0 - - 14569 » Total Conditioning - 9068 0 • 14569 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 15 of 18 Air System Design Load Summary for ZONE 16-KITCHEN R104 Project Name: 2017.092 FS 51 Tukwila Prepared by: The Greenbusch Group, Inc. 09/28/2018 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 26 ft' 688 26 ft' - - Wall Transmission 379 ft2 400 - 379 ft' 918 - Roof Transmission 1066 ft' 1783 1066 ft' 1375 - Window Transmission 26 ft' 19 - 26 ft' 166 - Skylight Transmission 0 ft2 0 - 0 ft' 0 - Door Loads 24 ft' 51 - 24 ft' 435 - Floor Transmission 1066 ft' 0 - 1066 ft' 935 - Partitions 0 ft2 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 746 W 2546 0 0 - Task Lighting 0 W 0 0 0 - Electric Equipment 0 W 0 - 0 0 - People 6 1470 1230 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6957 1230 - 3828 0 Zone Conditioning - 6610 1230 3833 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 900 CFM 0 - 900 CFM 0 - Ventilation Load 900 CFM 8068 -1230 900 CFM 46477 0 Supply Fan Load 900 CFM 0 - 900 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 14678 0 50310 0 Central Cooling Coil - 14678 0 - 0 0 Central Heating Coil - 0 - - 50310 - » Total Conditioning • 14678 0 - 50310 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 16 of 18 Air System Design Load Summary for ZONE 17- PHYSICAL TRAIN R106 Project Name: 2017.092 FS 51 Tukwila 09/28/2018 Prepared by: The Greenbusch Group, Inc. 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WB 82.5 °F / 63.8 °F HEATING DATA AT DES HTG HEATING OA DB t WB 23.0 °F /19.2 °F ZONE LOADS Details Sensible (BTUthr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 110 ft 5036 .. 110 ft' . - Wall Transmission 916 ft' 868 - 916 ft2 1577 - Roof Transmission 750 ft2 889 - 750 ft2 967 - Window Transmission 110 ft' 45 - 110 ft2 7D1 Skylight Transmission 0 ft2 0 - 0 ft 0 - Door Loads 63 ft' 73 - 63 ft' 1142 - Floor Transmission 750 ft' 0 - 750 ft' 875 Partitions 0 ft2 0 - 0 f12 0 - Ceiling 0 ft2 0 - 0 ft 0 - Overhead Lighting 525 W 1791 - 0 0 - Task Lighting 0 W 0 - 0 0 . Electric E uipment 0 W 0 - 0 0 - People 10 7100 10900 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous- 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 15802 10900 - 5262 0 Zone Conditioning - 15734 10900 - 5387 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0- Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 826 CFM 0 - 826 CFM 0 - Ventilation Load 375 CFM 2145 -7629 375 CFM 19378 0 Supply Fan Load 826 CFM 0 - 826 CFM 0 Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads • 17880 3271 - 24766 0 Central Cooling Coil - 17880 3273 - 0 0 Central Heating Coil - 0 - - 24766 - >> Total Conditioning • 17880 3273 - 24766 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 17 of 18 Air System Design Load Summary for ZONE 18- MECH PLATFORM R202 Project Name: 2017.092 FS 51 Tukwila 09/28/2018 Prepared by: The Greenbusch Group, Inc. 01:50PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WB 82.5 °F / 63.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Sotar Loads 77 ft2 3525 77 ft' - - Wall Transmission 765 ft2 1246 - 765 ft' 1233 - Roof Transmission 954 ft' 1130 954 If 1230 - Window Transmission 77 ft' 31 77 ft' 490 - Skylight Transmission 0 ft2 0 0 ft' 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 0 ft2 0 - 0 ft' 0 - Partitions 0 ft2 0 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 668 W 2278 0 0 - Task Lighting 0 W 0 0 0 - Eleclric Equipment 0 W 0 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 8212 0 - 2953 0 Zone Conditioning - 7613 0 3051 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 432 CFM 0 432 CFM 0 - Ventilation Load 114 CFM 642 -1 114 CFM 5892 0 Supply Fan Load 432 CFM 0 - 432 CFM 0 - Space Fan Coil Fans - 0 - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 8255 -1 - 8943 0 Central Cooling Coil - 8255 0 - 0 0 Central Heating Coil 0 - 8943 - » Total Conditioning - 8255 0 - 8943 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.91 Page 18 of 18 \ Johansen Mechanical inc. 20109 144th Ave NE • Woodinville, WA 98072 (425) 481-2266 Bus • (425) 486-6933 Fax 7/31/19 City of Tukwila Dept of Community Development 6300 Southcenter Blvd, suite 100 Tukwila, W A98188 RE: Peimit # M19-0098 Correction Letter #1 Response Dear Bill Rambo, We have reviewed your permit corrections and would like to submit the following corrected documents for review: . Reference to Addendum 9 have been removed, 4/19/19 date now reflects permit revisions set. 2. Plans now have wet seal and signed by Engineer of Record. 3. See the attached heat loss/gain calculations. If you have any questions, you can contact me at 425-527-1026 or via email at ivyl("&johansenmech.com. Thank you, eVangie Project Engineer Cc: D30600 Tukwila Fire Station 51 project file RECEIVED CITY OF TUKWILA AUG 0 1 2019 PERMIT CENTER CORREcTtou LTIR# oocir City of Tukwila Department of Community Development June 28, 2019 IVY LEVANGIE 20109 144TH AVE NE WOODINVILLE, WA 98188 RE: Correction Letter # 1 MECHANICAL Permit Application Number M19-0098 TUKWILA FIRE STATION 51 - 17951 SOUTHCENTER BLVD Dear IVY LEVANGIE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. 1 have enclosed comments from the following departments: BUILDING - M DEPARTMENT: LEE SIPE at (206)-431-3656 if you have questions regarding these comments. • Corrections required: 1. Addendum 9 dated 4/15/19 shown on plan is not shown on main plan set approved for construction. 2. Plan set not wet seal and stamped by architect or mechanical engineer which is required. 3. Please provide mechanical engineer heat loss/gain calculation, for review. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. M19-0098 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Reid iddleton June 14, 2019 File No. 262019.005 Ms. Rachelle Ripley City of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Subject: Building Permit Plan Review Tukwila Justice Center — HVAC (M19-0097) Tukwila Fire Station 51 — HVAC (M19-0098) Dear Ms. Ripley: Per your discussion with Katy Brawner the morning of June 14, 2019, Reid Middleton received permit documents for Tukwila Justice Center — HVAC (M19-0097) and Tukwila Fire Station 51 — HVAC (M19-0098). It was requested by the City that Reid Middleton perform review in association with the 2015 International Mechanical Code for these two projects. Reid Middleton can perform structural review but currently does not perform mechanical review. The two permits and associated documents are being returned unreviewed for distribution by the City for mechanical review. If you have any questions or need additional clarification, please contact us. Sincerely, Reid Middleton, Inc. Corbin M. Hammer, P.E., S.E. Principal Engineer Katherine R. Brawner, P.E. Project Engineer ehw\O:\Plan Review\Tukwila\19\TK19return 2 mech.docx\krb 19 009 8 RECEIVED CITY OF TUKWILA JUN 17 2019 PERMIT CENTER -Nth S7reet SW 98204 .•?..-alrriodieton.corn • 1 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director June 12, 2019 Dave Swanson Reid Middleton 728 - 134th Street SW, Suite 200 Everett, WA 98204 RE: Supplemental Structural and Non -Structural Review Development Permit D19-0180 Fire Station 52 — Vault & Retaining Walls -15447 65 Ave S Mechanical Permit M19-0097 Tukwila Justice Center — HVAC —15001 Tukwila Intl Blvd Mechanical Permit M19-0098 Tukwila Fire Station 51— HVAC —17951 Southcenter Blvd Dear Mr. Swanson, Please review the enclosed set of plans and documents for structural compliance with the 2015 International Building Code and the 2015 International Mechanical Code. As always, once all items have been reviewed and deemed correct, please provide two approved sets of approved plans and calculations with original approval stamps back to the Permit Center, attention Building Official. If you should have any questions, please feel free contact us in the Permit Center at (206) 431-3670. Sincerely, 6U(OZ-1,/(4/(1-(>) Kandace Nichols Permit Technician encl File: D 19-0180, M 19-0097, M 19-0098 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov ;ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0098 PROJECT NAME: TUKWILA FIRE STATION 51 SITE ADDRESS: 17951 SOUTHCENTER PKWY Original Plan Submittal X Response to Correction Letter # 1 DATE: 08/01/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 01,5ML.M9-161 Building Division 1111 Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 08/06/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required LI Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/03/19 E Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire D Ping PW 0 Staff Initials: 12/18/2013 PLA DP? OUTING SLIP PERMIT NUMBER: M19-0098 PROJECT NAME: TUKWILA FIRE STATION 5 SITE ADDRESS: 17951 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # DATE: 06/11/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C,D1212- 4\10 6\ Building Divisio • Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DATE: 06/13/19 Structural Review Required DATE: Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 07/11/19 Notation: REVIEWER'S IN T S: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire D Ping El PW D Staff Initials: 12/18/2013 Received at the City of Tukwila Permit Cente IF1 Entered in TRAKiT on City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: "7 131 / I e7 Plan Check/Permit Number: M19-0098 O Response to Incomplete Letter # • Response to Correction Letter # 1 0 Revision # after Permit is Issued Ej Revision requested by a City Building Inspector or Plans Examiner 0 Deferred Submittal # RECEIVED CITY OF TUKWILP. AUG 012019 PERMIT CENTER Project Name: Tukwila Fire Station 51 Project Address: 17951 Southcenter Pkwy Contact Person: 101 lizUel Phone Number: L12S- SZ (124, Summary of Revision: cocreC.14."-- (2-4-5170‘"-Se Wt 40.,C Cz-) c.o le4-e 5es 0 AI- ct.-S 0.5 a 6tA-c k.J470.•-- lAiex s (\4- c s Itfl 141 . Also 2-) Src-I-3 £ Nit aQ oave-S O.,- Siazs t9 1'44- t-Let.44 c Sheet Number(s): Ms LEA-4=S ScZ)v"- GICV I "Cloud" or highlight all areas of revision including dat of revision ivid701-CA CAUsers\ bill-eDesktop \Revision Submittal Form.doc JOHANSEN MECHANICAL INC 46, Page 1 of 2 floinc Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I 1=1 A-Z Index Help My IAA Workplace Rights Trades & Licensing JOHANSEN MECHANICAL INC Owner or tradesperson Principals JOHANSEN, KEITH ALLEN, PRESIDENT HOLM, DEREK RICHARD, VICE PRESIDENT JOHANSEN, ALLEN D, PRESIDENT (End: 06/04/2015) JOHANSEN, ANITA J, SECRETARY (End: 06/04/2015) Doing business as JOHANSEN MECHANICAL INC WA UBI No. 600 495 164 20109 144th Ave NE WOODINVILLE, WA 98072 425-481-2266 KING County Business type Corporation Governing persons KEITH JOHANSEN ALLEN JOHANSEN, Certifications & Endorsements License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JOHANMI173PK Effective — expiration 10/12/1983— 02/02/2021 Bond DEVELOPERS SURETY & INDEM CO Bond account no 275167C $12,000.00 Received by L&I Effective date 08/02/2010 07/31/2010 Expiration date Until Canceled Insurance Travelers Indemnity Company Th $1,000,000.00 Policy no. DTCO5K363952IND19 / /- • L TN A. • 1 C1T TTTT_/f% A A IN L- 1 I" A 0_1- TeT_ T/lT T A lk TX A'T 1 •-r norr ci A TT Help us improve n 1 IS in IS 1 A ABBREVIATIONS GRAPHIC SYMBOLS PROJECT DATA DIRECTORY DRAWING INDEX @ AT FP FIREPROOF PSI POUNDS PER SQUARE INCH PROJECT LOCATION OWNER GENERAL MECHANICAL 0 DIAMETER OR ROUND FPHB FROST PROOF HOSE BIB PT POINT/POINT OF TANGENCY DETAIL INDICATOR 17951 SOUTHCENTER PARKWAY City of Tukwila G001 COVER SHEET # POUND OR NUMBER FRM FRAMING PRESSURE TREATED �— 1 X ay— DETAIL NUMBER TUKWILA, WA 98188 Public Works Department EC I NICAL SCHED L S FRP FIBERGLASS REINFORCED PTD FIELD PAINTED ® SHEET NUMBER ECHANICAL SCHEDULES AB ANCHOR BOLT PANEL (NOT FACTORY FINISHED) �_ i LEGAL DESCRIPTIONS: 6200 Southcenter Blvd, Suite 100 ECHANICAL SCHEDULES ABE AVERAGE BUILDING ELEVATION FRDT FIRE RETARDANT PTN PARTITION NEW PARCELS BAND C AS DESCRIBED AND Tukwila, WA 98188 SET ABV ABOVE FRZR FREEZER DELINEATED ON CITY OF TUKW(LA BOUNDARY LINE Rachel Bianchi A001 ARCHITECTURAL FULL SITE PLAN ECHANICAL SITE PLAN ACT ACOUSTIC TILE FS FULL SIZE QTR QUARTER ELEVATION INDICATOR ADJUSTMENT NO. L 13-005, RECORDED UNDER T 206454 7566 A A002 ARCHITECTURAL SITE PLAN 3 ACW ALUMINUM -CLAD WOOD FSD FIRE SEPARATION DISTANCE QTY QUANTITY DETAIL NUMBER RECORDING NO.20130227900005, IN KING COUNTY E: Rachel.Bianchi@TukwilaWA.gov ECHANICAL FOUNDATION AD AREA DRAIN FT FOOT OR FEET XX Alt F 0 PLA : VE 7ANIC ]PLUMBING ADJ ADJUSTABLE, ADJACENT FTG FOOTING R RISERIRADIUS/RESISTANCE ® SHEET NUMBER TOGETWASHIHER TOGETHER WITH THOSE PORTIONS OF VACATED WITH IRE PROTECTION ABBREVDEXAFF ABOVE FINISH FLOOR AUTHORITY HAVING GA GAUGE RS RD RUBBER BASE ROOF DRAIN SOUTH 178TH STREETADJOINING, WHICH ATTACHED THERETO BY OPERATION OF LAW OWNERS REPRESENTATIVE Shiels Obietz Johnsen Q AliS N RG L00 P : LE L 1SO 3 A102 MECHANICAL PLATFORM & LOWER ROOF PLANJURISDICTION IRE PROTECTION FLOOR PAHJ GAL GALLON REC RECEIVE PURSUANT TO THE CITY OF TUKWILAORDINANCE (SOJ) 800 5thAve, Suite 4130 EVEL 1 PLUMBING PLANAHU AIR HANDLING UNIT GALV GALVANIZED REF REFERENCE ENLARGED ELEVATION INDICATOR NO.2400, RECORDED UNDER RECORDING NO. WA98104ALUMAL ECH PLATFORM AND LOWANALT ALTERNATE GEN GENERAL REFR REFRIGERATOR XX ® DETAIL NUMBER 20160120000736.Seattle, ALUMINUM GFI GROUND FAULT INTERRUPTER REINF REINFORCED SHEET NUMBER Justine Kim & Carrie Holmes® EVELIHVACPLANAP ACCESS PANEL GFRC GLASS FIBER REINFORCED READ REQUIRED T 206 838-3706 ECH PLATFORM AND LOW APPD APPROVED CONCRETE RET RETURN TUKWILAZONING E:cholmes@axispnd.com APPROX APPROXIMATE GL GLASS/GRIDLINE REV REVERSE/REVISEDIREVISION X MIXED USE OFFICE W/TUKWILASOUTH OVERLAY M601 LEVEL 1 PIPING PLAN ARCH ARCHITECTURAL ONO GROUND RF ROOF INTERIOR ELEVATION INDICATOR ARCHITECT M602 MECH PLATFORM AND LOWER ROOF PIPING PLAN ASP AVG ABOVE SUBFLOOR AVERAGE GOVT GR GOVERNMENT GRADE RFG RH ROOFING RIGHT HAND X `�— DETAIL NUMBER PROJECT# Q WeinsteinA+U GALVANIZED SHEET METAL RIGID RIGID INSULATION AXXX ® SHEET NUMBER D18-0321 2200 Westem Ave, Suite 301 ANICAL ROOF PLANGSM SAL BALANCING BOARD GWB GYP GYPSUM WALL BOARD GYPSUM RL RM RAIN LEADER INTERIOR ) ROOM X/—PROJECT ELEVATION( DESCRIPTION CONSTRUCTION A NEW, SINGLE FIRE Seattle, WA98121 Q3 ANICAL LARGE SCALE PLANSBD ANICAL DIAGRAMSBE BATH FAN EXHAUST RND ROUND -STORY Emma Nowinski & Lauren Rock BUILDING SECTION INDICATOR STATION FOR 6 ON -DUTY STAFF AND ASSOCIATED T 206443-8606 =PLAN ANICAL SECTIONSBEL BELOW HB HOSE BIB RIO RANGE/OVEN SITE IMPROVEMENTS. BUILDING TO HAVE A BEY BEYOND HC HANDICAP/HOLLOW CORE RO ROUGH OPENING XX '� DETAIL NUMBER THROUGH APPARATUS BAY E: emman@weinsteinau.comBLDG ANICAL DETAILSCONFIGURATION. BUILDING HD HEAD/HEAVY DUTY ROW RIGHT-OF-WAY .® SHEET NUMBER CONFIGURA ION SITE I SITE IMPROVEMENTS TO HANICAL DETAILSBILK BLOCK, BLOCKING HDR HEADER RUB RUBBER INCLUDE PAVED FIREFIGHTER DRILLING AREA, CIVIL ENGINEER HANICAL DETAILS BM BENCH MARK HDWD HARDWOOD RWL RAINWATER LEADER (INDOORS) EMERGENCY GENERATOR AND APPARATUS LPD Engineering BO BOTTOM OF HWVP HARDWOOD VENEER PLYWOOD FUELING STATION. 1932 First Ave, Suite 201 M905 MECHANICAL DETAILS BOT BOTTOM HDWR HARDWARE S SOUTH WALL SECTION INDICATOR BRK MTL BRAKE METAL HE HOOD FAN EXHAUST SAW SALVAGE (D) (xx m— DETAIL NUMBER Seattle, WA 98101 BTWN BETWEEN HM HOLLOW METAL SAM SELF-ADHESIVE MEMBRANE Yf' s— SHEET NUMBER Marc Servizi HOL HOLLOW SBC IBC wl SEATTLE AMENDMENTS T 206 725.1211 C to C CENTER TO CENTER HORI SC SOLID CORE E: mares@ipdengineedng.com CAB CABINET HORIZ HORIZONTAL SCHED SCHEDULE CAP CAPACITY HP HIGH POINT SCW SOLID CORE WOOD CG CORNER GUARD HR HOUR SD SMOKE DETECTOR xt3 EXTERIORITHERMAL LANDSCAPE ARCHITECT CHIT BABY CHANGING TABLE HT HEIGHT SECT SECTION ASSEMBLY INDICATOR Swift Company, LLC CIP CAST -IN -PLACE HWH HOT WATER HEATER SF SQUARE FEET I STOREFRONT 3131 Western Ave, M423 CJ CONTROLJOINT SH SHELF A A1 PARTITION TYPE INDICATOR Seattle, WA98121 CL CENTERLINE IBC INTERNATIONAL BUILDING CODE BHT SHEET Shawn Stankewich CLG CEILING ID INSIDE DIAMETER SHTG SHEATHING CLKG CAULKING IN INCHES SID SIDING T2066322038 CLO CLOSET INCL INCLUDE (D) (ING) Sim SIMILAR St3 E: shawn@swiftcompany.com CLR CLEAR [NCR INCREASE SL SLOPE FLOOR ASSEMBLY INDICATOR CMU CONCRETE MASONRY UNIT INSUL INSULATION SLNT SEALANT STRUCTURAL ENGINEER COL COLUMN INT INTERIOR SPEC SPECIFICATIONS Swenson Say Faget CONC CONCRETE INTM INTERMEDIATE SPRT SPORT FLOORING (RUBBER) COND CONDITION INTUM INTUMESCENT SQ SQUARE WINDOW INDICATOR 2124 Third Ave, Suite 100 CONN CONNECTION INV INVERT SST STAINLESS STEEL Seattle, WA 98121 CONST CONSTRUCTION STC SOUND TRANSMISSION CLASS Dan Morrow CONT CONTINUOUS JST JOIST STD STANDARD/STUD T 206 443 06212 CONTR CONTRACTOR JT JOINT STIFF STIFFENER E: dmorrow@ssfengineers.com CORR CORRIDORICORRUGATED STL STEEL CPT CARPET L LONGILENGTH STOR STORAGE xxx DOOR INDICATOR CT CERAMIC TILE LAM LAMINATE STFNT STOREFRONT MECHANICAUPLUMBING ENGINEER CTR CENTER LAV LAVATORY STRUCT STRUCTURAL The Group, Inc. CUST CUSTOM LE LAUNDRY FAN EXHAUST SUB SUBSTITUTE W Nickerson 1900 Nic on St, Suite 201 CWP CLEAR WALL PANEL LH LEFT HAND SUSP SUSPENDED Seattle, WA 98119 L1N LINEAR LINEAL SYM SYMMETRICAL A D DEEP (DIM)/DRYER LOCH LOCATION SYS SYSTEM John Greenlaw DE DRYER EXHAUST LP LOW POINT T..206378-0569 DEPT DEPARTMENT LT LIGHT T TOP/TREAD/TOILETTEMPERED E iohng@greenbusch core DETIDTL DOM TIC G DETAIL LTG LIGHTING T & G TONGUE&GROOVE 1 LAYOUT GRID DF DRINKING FOUNTAIN LVL LEVEL TSTAT THERMOSTAT DIA DIAMETER TIC TOP OF CURB ELECTRICAULIGHTING ENGINEER DIAG DIAGONAL MATL MATERIAL TD TRENCH DRAIN TFWB Engineers Inc. DICA DRILLED -IN CONC ANCHOR MAX MAXIMUM TEL TELEPHONE 1200 Westlake N, Suite 509 DIM DIMENSION MC MEDICINE CABINET TEMP TEMPORARYITEMPERATURE/ Seattle, WA98109 DIR DIRECTION MDF MEDIUM DENSITY FIBERBOARD TEMPERED — — GRID LINE Kevin Warteile DIM DIVISION MECH MECHANICAL THK THICKNESS) T.206285-7228 ON DOWN MEMB MEMBRANE THRU THROUGH DP DAMPROOFING MFR MANUFACTURER TO TOP OF E: kevin@travisfitzmaudce.com DO DITTO MIN MINIMUM TOC _ _ TOP OF CONCRETE PROPERTY LINE DR DOMES MISC MIS ELLANEOUS TOPOFCURD DOOR MLDG MOLDING TOIL TOILET — — — — — — — — — — — — — OVERHEAD LINE TRAFFIC SIGNALIZATION WHPactfic DS DOWNSPOUT (EXTERIOR) MO MASONRY OPENING TOP TOPPING/TOP OF PLATE 12100 NE 195th St, Suite 300 DW DISHWASHER MOT MOTORIZED TOP OF PARAPET DWG DRAWING MTD MOUNTED TOSF TOP OF SUBFLOOR Bothell, WA98011 MET/MTL METAL TOW TOP OF WALL —'—'—'—'—'—'---'—'— CENTERLINE Jerry Liu (E) EXISTING TP TOP OF PAVEMENT T. 425 9514823 SEPARATE PERMIT REQUIRED FOR: E EAST N NORTH TRANSL TRANSLUCENT — - — • — - — • — • — • — - — - — E: jliu@whpac tic.comC3 Me EA EACH IN) NEW TRTD TREATED 1•HR FIRE RATED � Electrlcel EL ELEV ELEVATION NAT NATURAL FINISH TV TELEVISION ELEVATOR NEG NEGATIVE TWP TRANSLUCENT WALL PANEL FIRE STATION SPECIALIST ARCHITECT Plumbing ELEC ELECTRICAL NIC NOT IN CONTRACT TYP TYPICAL — • • — • • — - • — - • — • - — • — INTERIOR AIR BARRIER TCAArchitecture Gas Piping EMER EMERGENCY NO or# NUMBER 6211 Roosevelt Way NE Cital Tukwi a EMR ELEVATOR MACHINE ROOM NOM NOMINAL UL UNDERWRITERS' LABORATORY Seattle, WA 98115 BUILDING DIVISION EQ EQUAL NTS NOT TO SCALE UNPIN UNFINISHED — — — — — — — AIR BARRIER Brian Harris EQJ EARTHQUAKE JOINT UNOIUON UNLESS NOTED OTHERWISE EQPT EQUIPMENT OA OVERALL T206522-3830 EPL EMERGENCY PATHWAY LIGHTING OC ON CENTER VAP VAPOR BARRIER E: bdan@tca4nacom EST ESTIMATE; ESTIMATED OD OUTSIDE DIAMETER VAR VARIESNARIABLE EW EACH WAY OFD OVERFLOW DRAIN VS VINYL BASE EXC EXCAVATED ON OPPOSITE HAND/OVERHEAD VCT VINYL COMPOSITION TILE CONCRETE EXH EXHAUST OHW ORDINARY HIGH WATER VENT VENTILATION EXIST EXISTING OPNG OPENING VERT VERTICAL EXP EXPOSED OPP OPPOSITE VEST VESTIBULE EXPAN EXT EXPANSION OVHD OVERHEAD VFY VERIFY EXTERIOR OWSJ OPEN -WEB STEEL JOIST VIF VERIFY IN FIELD REVISIONS OZ OUNCE VG VERTICAL GRAIN BRICK No c -r:aes snail 2e Made to the scope FAB FABRICATED VOC VOLATILE ORGANIC COMPOUNDS of work wnnout prior aporoval of the FB FLUSH BEAM (P) PROPOSED VOL VOLUME Tukwila Bmldmg Division. FBRGL FIBERGLASS P FIELD PAINTED VS VINYL SHEET/SHEET VINYL NOTE: Revisions will reowre a new plan FC FIBER CEMENT COMPOSITE (NOT FACTORY FINISHED) VTR VENT THROUGH ROOF submittal and may include additional FD FLOOR DRAIN PAR PARALLEL plan review. FE FIRE EXTINGUISHER PART PARTITION W WESTANIDEM+ASHER F-1 FF FINISH FLOOR/ PC PRECAST W1 WITH GWB FACTORY FINISHED PERF PERFORATED W/o WITHOUT FG FINISH GRADE PERP PERPENDICULAR WAIN WAINSCOT FP FACTORY PRIME PAINTED PKG PARKING WC WATER CLOSET FS FEDERALCABINSSPECIFICATION PL PLATEIPROPERTY ElPLASTIC WD WOOD FEC FE CABINET PLAM PLASTIC LAMINATE WDW WINDOW LAMINATE FIN FINISHED) PLYWDI WSEC WASH. STATE ENERGY CODE RIGID INSULATION FLASH FLASHING PLY PLYWOOD WGL WIRE GLASS FLEX FLEXIBLE PNL PANEL WH WALL HUNG RECEIVED FLR FLOOR PNT PAINT(ED) WIND WINDOW CITY OF TUKWILA FOC FACE OF CONCRETE POL POLISH/POLISHED WP WATERPROOFING) MEMBRANE FOP FACE OF FINISH PPL POLISHED PLATE WR WATER REPELLENT AUG 01 2019 FDIC FURNISHED BY OWNER, PR PAIR WRB WEATHER RESISTANT BARRIER FIBER INSULATION INSTALLED BY CONTRACTOR PREFAB PREFABRICATED) WS WEATHERSTRIP PERMIT CENTER F010 FURNISHED BY OWNER, PREFIN PREFINISH(ED) WT WEIGHT INSTALLED BY OWNER PRELIM PRELIMINARY wwM WELDED WIRE MESH FOM FACE OF MASONRY PROD PROJECT/PROJECTION FOS FACE OF STUD PROP PROPERTY YD YARD DRAIN PROX PROXIMITY SEMIRIGID INSULATION CORRE TION LTR GENERAL NOTES RENDERING VICINITY MAP g 1. ALL WORK SHALL BE IN COMPLIANCE WITH THE REQUIREMENTS OF THE 2015INTERNATIONAL BUILDING CODE IBC , 8. GRADING MUST BE STABILIZED BY OCTOBER 31. NO EXCAVATION TO BE PERFORMED BETWEEN OCTOBER 31 2015 WA STATE ENERGY CODE, 2015INTERNATIONAL FIRE CODE, AND ALL OTHER APPLICABLE CODES AND APRIL 1 WITHOUTAN APPROVED DRY SEASON GRADING EXTENSION LETTER FROM THE DEPARTMENT OF 516Bttr 5t o I?Trr" COMMUNITY DEVELOPMENT. 2. CONTRACTOR SHALL FIELD CHECK ALL DIMENSIONS AND VERIFY LOCATION OF WORK WITH THE ARCHITECTS, t>'L a ':x NO SCALE MEASUREMENTS SHALL BE USED AS DIMENSIONS FOR WORK. LARGER SCALED DETAILS AND 9. DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER. NOTIFY THE ARCHITECT WHENEVER DIMENSION DESTINATION OF EXCAVATION SOILS TO BE DETERMINED. THE DEPARTMENT OF COMMUNITY DEVELOPMENT " WILL BE NOTIFIED OF DISPOSAL SITE AFTER CONFIRMATION BY EARTHWORK SUBCONTRACTOR. Tr ,zaT y McMickerl d t3 i�tg11 t5 o Mi i a Wi $tvrf' $ e DISCREPANCIES ARISE. v .. k 1 i 10. DRAWINGS ISSUED FOR CONSTRUCTION PRIOR TO FINAL PERMITTING APPROVALARE SUBJECT TO REVISIONS. F 3. ISS L CONTRACTOR OLE YAND COMPLETELY RESPONSIBLE FOR CONDITION OF THE JOB SITE, INCLUDING SAFETY, PROTECTION OF THE PROPERTY, AND THE LIKE DURING PERFORMANCE OF THE WORK. VERIFY CONSTRUCTION DOCUMENTS CONFORM TO PERMIT DRAWINGS BEFORE PROCEEDING WITH WORK. • . NOTIFY ARCHITECT WHEREVER DISCREPANCIES ARISE. �i...,�a �..,.. .. 9i, sin � u ,,. 1 S 5t —_= tatlnC<ter.BCvc€ I 778rd 4. CONTRACTOR .; SHALL PROVIDED METHODS, MEANS, AND FACILITIES REQUIRED TO PREVENT CONTAMINATION 11. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, ELECTRICAL, MECHANICALAND SLGNAGE WORK. OF SOIL, WATER OR ATMOSPHERE.` „ rb 5. 12. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S WORKAND/OR SUPPLIED DIMENSIONS ARE TO: FACE OF MASONRY (FOM), `-'_ 5,17t11'St x ITEMS THATARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTS OR ARE NOT IN CONTRACT, BUT ARE FACE OF CONCRETE (FOC), OR __ �o off' COstCo Dr ATTACHED TO THE CONTRACTOR'S WORK. FACE OR STUD (FOS) UNLESS NOTED OTHERWISE (UNO) _ $'17$#tT� r a 6. BUILDING IS TO BE FULLY SPRINKLERED. DIMENSIONS INDICATED AS CLEAR (CUR) OR FINISH (FIN) ARE TO FINISH FACE. 7. ALL FURRED WALLS SHALL HAVE VERTICALAND LATERAL DRAFTSTOPS PER IBC. 13. THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENTS THAT IN MY PROFESSIONAL JUDGEMENT ARE APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCW 64,55.005 THROUGH 84.55.090. i ,, _, , 5'7SGttt S j , '.��rh5x riiiia 3 4/4/19 Permit Revision 18 12/11/18 Design Revisions IA 12111/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17951 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by LR Drawn by TM Checked by EN �.GREP wwsrt O yr ri �p ,P 22833 s, F0 1 STER4' Sr�NAL 6N yL> Issue MECHANICAL PERMIT Date 7/25/19 Sheet Title COVER SHEET kA 04 Lu U tA w 0 Z Q 0 •I- tA N V w h V Q �, J RESIDENTIAL PROP8R,11� PROPERTY ,nre I V I I 'D FOR REVEV: IN CODE COMPLIANCE APPROVED AUG 0 8 2019 ISEE A002.A FOR ENLARGED ARCHITECTURAL S� CRY Of Tukwila -BUILDING DIVISION D FOR MPL'ANCE OVED 8 2019 u v . k 'la DIVISION DUN .... . ....................... ................. .... ..................... .......................... RECEIVED CITY OF TUKWILA 00 AUG 0 12019 ti PERMIT CENTER ARCHITECTURAL FULL SITE PLAN 001 SCALE: 1132"= V-0' GENERALNOTES I SEE CIVIL PLANS FOR UTILITIES, PAVING & GRADING 2 SEE LANDSCAPE PLANS FOR PLANTINGS & SITE FURNISHINGS PROPERTY LINE EXISTING CONTOURS NEW CONTOURS SECURITY FENCE SETBACK PERVIOUS CONCRETE ASPHALT PAVEMENT GRAVEL 3 414/19 Permit Revision 113 12/11118 Design Revisions 1A 12111118 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 (1) Project No. 17001 Designed by U1 Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com @ 2018 Weinstein A+u -These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or In other locations without the approval and participation of the Architect. RE�GSTERE R IT �T 3300 �ARCHITECT, '�E WARD W�EINSTEIN State of Washington Issue PERMIT SUBMITTAL Date 10/15/2018 Sheet Title ARCHITECTURAL FULL SITE PLAN Sheet A001 ON P-1 ij 7'H SECURITY FENCE TYPAT U NORTH, WEST & SOUTH SIDES, TW LOCKABLE GATE SEE LANDSCAPE G13 I 3 T 34'-0" LIGHT POLE, SEE ELEC 2) FIXED BOLLARDS 19'-0 1' 6" GRAVEL I I ROUND OOP SENSOR, PER ELEC PTO GAL STLASSEMBLY FOR MTG TRAFFIC CONTROL BUTTON COORD W/ ELEC N w REAR AP ;o iQ3 A IY ~ I I 7'H ARCH SCREEN W/ ELECTR �Gl SECURITY I I ASPHALTPAVING 1, SEE CIVIL k i 4 lei 4 N W A' ktr, — 19 WALL-MTD FDC PIV 40'H LIGHTED FLAGPOL W/ CONIC BASE FRONT APRON 39'.101/2" CL OF S 180TH S I (N) FIRE HYDRANT ON CONCRETE CATCH BASIN, TYP 0'-0' SIDEYAR TRACK BE CIVi� PER 16.41.0906 � HEAVY-DUTY CONCRETE TYP UNO LINE OF PTD STL FIXED 7OVERHANGABV BOLLARD T4- - I I HEAVY-DUT, CONCONCRET ----------- . _ (E) TRAFFIC SIGNAL—►O --.� BIKE RAC Q _ I I I LINE OF OVERHANG Ad ENTRY KIOSK f SEE LANDSC, 10'X30' LOADING SPACE-),/ _ H ,' to UTILI ENCLOSURE (GENE T R & TRASH) ZpA I L — ASPHALT PAVING S� SEE CIVIL 1 0 I' — — PE Y 19'-0" 16" INE F 'ERH I Y e o T; TH SECUIFENCE I ENCLOS E & UTILITY METER OU TY D — — FDR - O CONAD fRR1QATi6NfOtNTGFG6NP1- — Q ATEEGRESSBUTTON GROUND LOOPSEN I ab. - -Gf4-- ----� _ i G11 7'H MTL ARCH SCREEN W/ ELEC SECURITY GATE ; PTD STL FIXED BOLLARD � EPARATOR U 1 OILNVATER GAS METER K) O `BELOW ALCOVE ? -' TRY F TURE EV CHARGIN TION, SEE E HEAVY-DUT ELEC NG G G STATION GHT POLE, SEE ELEC CENTER ON PARKING CONCRETE ? PTD GALVSTLASSEMB FOR MTG ELEC GATE SECURITY KEYPAD (N) CONCRE %OLLARD LIG T COORD W/ ELEC SIDEWP LIGHT POLE SEE ELEC Q_ %OLLARD LIGHT- ONC PAVEMENT Q SIGNALIZRTIONPOLE /L' �1✓RP Q SEETSOt �S t� I I I N11°5553 W 9A.05 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila BUILDING DIVISION = RECEIVED CITY OF TUKWILA I ZONE: MUO (MIXED USE OFFICE) WITH TSO (UKWILA SOUTH OVERLAY DISTRICT) ca AUG 0 12019 30'41/2" 30.0112" PERMIT CENTER /'l—'N ARCHITECTURAL SITE PLAN 00 SCALE:1/16"= V-0" ® i GENERAL NOTES 1 SEE CIVIL PLANS FOR UTILITIES, PAVING & GRADING 2 SEE LANDSCAPE PLANS FOR PLANTINGS & SITE FURNISHINGS PROPERTY LINE EXISTING CONTOURS NEW CONTOURS SECURITY FENCE SETBACK PERVIOUS CONCRETE ASPHALT PAVEMENT GRAVEL 3 414119 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by LR Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com © 2018 Weinstein A+U -These documents have been prepared specifically for the above named project. They are not suitable for use on other projects a in other locations without the approval and participation of the Architect.- 3300 REGISTERS ARCHITECT EDWARD WEINSTEIN State of Washington Issue PERMIT SUBMITTAL Date 10/15/2018 Sheet Title ARCHITECTURAL SITE PLAN Sheet V1 W LLI V Ln w n Z Q m Ce V1 Ce V w H 2 V Q �, rill fn_ 1 2.1 15'-111F 117 464' GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 0 7 DOOR SCHEDULE -SEEA911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015IBC - - - - INTERIOR AIR BARRIER I I I PARTITIONS 1 RASH 326 002 I �--'""I I ro x STLCANOPYABOVE� -. -.--- _ - - - - -�- - \1 0 0 ( HB H2 ! H2 126E 127 7228 / o C 1 A 1 }C.} L. --�'' E POST MTDHB N RECEIV HB A 0 S DBUNK BUNK Z2012- 11 y X1A WDECON r 126 ! A 1 121 120 o f 0 00 D C 1 A 125 126A F u D 122A 127120A -- FEC AIRLOCK ¢ J 0 V A 0 m 123 CORRIDOR �I -•-•_ x A 119 i �' --• - - - - - - - - - - q128 B� E FUTURE ETak WICl G ASH p LAUNIJAN 14 H N 128 A 0 17 III 01 DD -, A o a H1 I E B 0 ( 129A C �� c - 11 1 I �E 3 4/4119 Permit Revision X1D HB Y ° A 0 o B E 328 I I j j 1B 12111/18 Design Revisions " H 0 116A B� H1 ! l to 12111118 Permit Corrections #1 13 L I 'I' 116 I i l i TRAIN A301 ]i o BATH I O I 08, m Rev Date Issue HYS GEAR STOR 115 l I G2 APP BAY N 129 A 0 COURTYARD I' C 130 — CORR C It (OPENTOABOVE} i I O Tukwila Fire Station 51 O 8 0 DA BATH i10 I 114A n BUN l ° j I ; y I TH SECURITY Tukwila, SouA 981 8 Parkway - Ate— I 113 A 114 Ht 16 t FENCEAROUND Tukwila, WA 98188 r B H O, FED i I TRANSFORMER J - CANOPYABOVE—i►I II �I --- ------------------ �'_ A 0- -- C 1 I ( I l � 7 I I I I I � Project No. 17001 - I 112A N ( I I ( I ... t i I CAP BIJi 6 f 1, 1 ❑ A311 EMS ;I; ;I; A 0 D 112 27 I I —'�A 311 Designed LR III��� 1 o BATH C H1 C 1- l( 9 Y --' 132 A 1N I Gt 4 I I r B { G14 rawnby TM `' - - - - 132 - - - - - - - - = 106B _ _ _ hacked by EN _ - - - - -� ---- ------ (CORRIDOR A O c AIRLOCK of CORRIDOR C 1 _.... 131 G� ,�°) 109 A A E 105 G11 103 A FE ! • � X2 � ' einstein A+U U 1g3 _ _ _ _ _ _ o A 0 1200 chitects + Urban Designers, LLC 0 A 0 ! l Western Ave ion- •/ B 0 = - " ' r D ADAW-.-._..o O 1016 A 0GA-------------- ---' A O B A 0 0 102 A 0 ! ME ER 1 3 M Seattle, WA 98121 N B 0 p 1H 0 A 0 E 0 AL VE I 329 ° f. THARCHITECTURAL SCREEN WI D ENTRY VESTIBULE Y Q T 206 ELECTRIC SECURITY GAT MECH STATION OFFICE 1 108 E 101 j � KITCHEN JELE SEESHEETA004 FOR DETAILS F 206 4431218 133 = _ _ = 107 104A ' _ www.weinsteinau.com +01, 0 g I CAP OF ICE I , 3 1048 M 00 Vd AA 02078 Weinstein A+U -These documents have been ° „ iry, q, p p I A 0 108 A 0 �t35.0°) B prepared specifically for the above named project. --------1 B d '� 13 •-•-d '-' '--' I 1 _ �'`� / They are not suitable for use on other projects or In •-•-•-•-•-•-•-• �. •-• •-r--_ :.: _ - _ _ _ _ _ _ _ _ _ _ _ _ T_ _ _ _ _ other locations without the a approval andparticipation --=0-=---___ - - - - - - - - - A — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — PMo of theArchited. 3 I ------- 0 I TJI 8 GEN SEE 11A101S SEE 1IA101N 003 z 2 I e A30t LINE OF BA RIER A311 ONTINUITY AT INTERIOR 1 ----------------- ' � D i 1 1 ----- -- - - 324 A325 1) FIXED ❑ ARCH 8CREEN W1 ELEC - BOLLARD 3 SECURITY GATE TH 3 -------------- ----- E _ _ 130D 130C- ----' STOR- I �-- --- ° 138 1 1 I I 1 I G15 CASCADE g 0 c FILL STATION (FO-- g 1 ( - u 'I L - - - - - ----J L---- ----J CORRIDOR A D 135 137 CLEAN D _ _ 136 - - - - - - CBA F --RE PARTtSI I I 137 AMER WALL-MTO FDC I I O I O tOtA *H O Bt e i O SEE MECH 2 _ _ _ _ I _ O FLAG POL 3'.0" 8 i 2 STLCANOPY ROVE PIV 322 32 003 21 Q / PTO STL KIOS FOR MOUNTING EM RGENCYPHONEAND MAILBOX SEE1/A101S SEE1tA101N COORDWIEL C. I I I U rY Q Q Issue PERMIT SUBMITTAL Date 10/15/2018 (f1 / Sheet Title FLOOR PLAN LEVEL 1 RECEIVED 1 FLOOR PLAN LEVEL 1 CITY OF TUKWILA UJ 101 SCALE:118° = r•o° AUG 01 2019 Sheet A101 3: PERMIT CENTER 1 2 / 30 A311 / REVIEWED FOR / ODE COMPLIANCE /1PPR0VED AUG 0 8 2019 1 2.1 1 3.1 4 0 ity of Tukwila BUI ING DIVISION 4 5 6 7 I 1 16-67/16" T-8" I T-81/16" '- 8'-103/8" �--- -•--.-.-.-. .. .-. .-.-. ._._.. ------------ --'-•-•-•-• \ FLUSH FLOOR GRATE I I ' WITH AREA DRAIN BELOW j CLR 12G�" 127 122E MIN CLR MIN NI' WALL-MTD OR - —PULL- - - - - - % S A617 1 EYE WASH \ F010 I or it ��� i, FD� 1 L�I •\ / - - -----•--•-•-•-•-• ri - E i SSTD INBOARD COUNTERWt-.-.-.-. _ _._.-.-.-- i L SINK & BACKSPLASH INTEG I I 2 6"L X 10"D SUPPORTED RECEIV igySTL BES ON WALL STUDS F 1-22-1BUNK 127Com1 12 1-1 N j 127 I � � � I 116 1'-0" CLR MI N I¢ --- F CON 1267 11 MI Jd FD N q-� 126 4", HANGING BAR— W 121 I SSTSHELF A61 125 ABV I R N MAP WALL - W ( SST SHELFABV o> I FD Q i 1 00 9'-2° m II I S 671 I II 15 I J j II 121A --- CURTAIN 1 A 122A _ _ BOOT WASH ------ TBACK A ff0 6'-11 112" 6'-9 5/16" =5' g T-4 7116" 5'-0" 4'= - - - - - CORNERGUARD (SEEINTELEVATIONS) AIRLOCK N 4� 2'-11116" CORRIDOR r�'z 1 119 CORNER GUARD FLUSH FLOOR GRATE SEE INT ELEVATIONS} V.0" 6'-1518" -4 1. WITH AREA DRAIN BELOW CLR - 128 IN W HANGING FOLD -DOWN r IRONING BD GEAR WASH 3 BAR LAUNWAN S A61 N LINE OF 11BA 128 S EXTRACTOR 117 E SOFFIT ABV A617 n �I HANGING BAR FD MOP SINK VVY PLUMB FOR n BRACE &SHELF E------- SST SHELFABV "FUTUREW/D BUILT-IN SHIFT o FRAME, TYF'—► I'. LOCKERS, TYP. Q i SEESTRUCT lilt W D it I 116A 3 INTERIOR ELEVATIONS A61t �� I A614 SIM BATH 111 WALL MTD GEAR LOCKERS, NIC j QFD BATH j ^ E ?_4 115 h_ � I (_n GEAR9TOR j kI I CORR M j S b i 110 I 114A N A. BA `2 14 N L------- - FD U j A619 I j I ( a12A w I I -TRENCH DRAIN I' I I I• >) S 16 I !� m OPEN MTL SHELVES FD BA 2'-0"D WALL-MTD A611 E CORNER UARD I trF— LINI OFOVHD "1 rD00RS""" I CORNER GUARD (SEE INIi ELEVATIONS II I I I I I I I it 14'-2 31F ° AIRLOCK � # 109 4 A617 SH: �z FLUSH FLOOR GR 4 WITHAREADRAIN BELOW,TYP F2 I J-JI � I`-L-JI A704 —/ 7WALL-MTD L-tAmS TV WHITE BOARD I I STATION OFFICE 107 W A614>N S BUNK 120 1.0" CLR MIN 1 -11 71 120 I 120A LL 1/4" 5'-0" T 12'-11/16" V 8'-1718" BUNK n 118 I � I WALL-MTD HVpp) UNIT ABV, TYP z' I Q�z I SUM N SHELF <I HOOKSI *-A N E BUNK 116 z BUILT-IN DESK &I HEADBOARDJT S,�z I c�� I�q,��r ril I r 1� BUNK 1 I 114 I z;� I n 1 CAP BUNK j I 172 i O O I — - - - - - - - - - -------- CONC & I J W IgEflQAR '-'-'-'-'�E PO SHED CONC FLR �" INDIVIDUAL F000 SST BAR SINK LOCKERS, 4 HIGH 105 W S A612 N i 7-8 5/ BUILT-IN I E CASEWORK GAS 19 FOFTOALIGN I METER A612 1� I ALCOVE Q 13 4"CLR T t4 KITCHEN 14 E ELEC A612 104A A612 I 105 •\ I DAYROOM --- 104E 19 v ON CONC PAD 8'H "It GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REDID FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE - SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015IBC INTERIOR AIR BARRIER 4 o E ?A --....... -._._._._._._._.•_._. 1- •-•�•BUILT-IN DESK M I cwrurry o �35�D dor j \ E W/ SHELVES ABV r 108 I I WD BE CH -- -I - - WI UPPERS �--BUI6TIND€�.K --- - - - - - j - - - - /t• - 7NO:\----------------- - - - _. . ,I 15 �,, 101a — _ CODE COMPLIANCE ens 10'. 112° r-9114" 1 41'-87/8 9-51/2" APPROVED ._ --- -1__': - - - - - - _ - 11'-358f 4'R08" T-35 " 2'R�B" i12'-35t8" B ROB" T-35/8" 2'R03t8" I 21'35/8" 2'R08" 24'35i6" AUG 08 2019 II----------- -I'------- 1 ' I \ i - \•` City of Tukwila •—•—•— — — — — — — — — — — — — — _ _-_._.—�._._._._. BUILDING DIVISION 1 z1 RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 1 ENLARGED FLOOR PLAN LEVEL 1 NORTH 101 SCALE:1/4" = V-0" M11 wit 1B 12/11/18 Design Revisions to 12111118 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by LR Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com ® 2018 Weinstein A+U -These documents have been prepared specifically for the above named project They are net suitable for use on other projects or in other locations without the approval and participation of the Architect. 3300 REGISTERE ARUC�HgI'T�E^C�'T EDWARD WEINSTEIN State of Washington Issue PERMIT SUBMITTAL Date 10/15/2018 Sheet Title ENLARGED FLOOR PLAN LEVEL 1 NORTH Sheet A101 I I 120A LL 1/4" 5'-0" T 12'-11/16" V 8'-1718" BUNK n 118 I � I WALL-MTD HVpp) UNIT ABV, TYP z' I Q�z I SUM N SHELF <I HOOKSI *-A N E BUNK 116 z BUILT-IN DESK &I HEADBOARDJT S,�z I c�� I�q,��r ril I r 1� BUNK 1 I 114 I z;� I n 1 CAP BUNK j I 172 i O O I — - - - - - - - - - -------- CONC & I J W IgEflQAR '-'-'-'-'�E PO SHED CONC FLR �" INDIVIDUAL F000 SST BAR SINK LOCKERS, 4 HIGH 105 W S A612 N i 7-8 5/ BUILT-IN I E CASEWORK GAS 19 FOFTOALIGN I METER A612 1� I ALCOVE Q 13 4"CLR T t4 KITCHEN 14 E ELEC A612 104A A612 I 105 •\ I DAYROOM --- 104E 19 v ON CONC PAD 8'H "It GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REDID FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE - SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015IBC INTERIOR AIR BARRIER 4 o E ?A --....... -._._._._._._._.•_._. 1- •-•�•BUILT-IN DESK M I cwrurry o �35�D dor j \ E W/ SHELVES ABV r 108 I I WD BE CH -- -I - - WI UPPERS �--BUI6TIND€�.K --- - - - - - j - - - - /t• - 7NO:\----------------- - - - _. . ,I 15 �,, 101a — _ CODE COMPLIANCE ens 10'. 112° r-9114" 1 41'-87/8 9-51/2" APPROVED ._ --- -1__': - - - - - - _ - 11'-358f 4'R08" T-35 " 2'R�B" i12'-35t8" B ROB" T-35/8" 2'R03t8" I 21'35/8" 2'R08" 24'35i6" AUG 08 2019 II----------- -I'------- 1 ' I \ i - \•` City of Tukwila •—•—•— — — — — — — — — — — — — — _ _-_._.—�._._._._. BUILDING DIVISION 1 z1 RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 1 ENLARGED FLOOR PLAN LEVEL 1 NORTH 101 SCALE:1/4" = V-0" M11 wit 1B 12/11/18 Design Revisions to 12111118 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by LR Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com ® 2018 Weinstein A+U -These documents have been prepared specifically for the above named project They are net suitable for use on other projects or in other locations without the approval and participation of the Architect. 3300 REGISTERE ARUC�HgI'T�E^C�'T EDWARD WEINSTEIN State of Washington Issue PERMIT SUBMITTAL Date 10/15/2018 Sheet Title ENLARGED FLOOR PLAN LEVEL 1 NORTH Sheet A101 I I a SCALE:1/4" = V-0" C 0 A I ---- --------------------- ---- 1 324 ------------------------------------------- 17'-3 5/8" 31/2° 3" ,l -------- --- ------------------ --'� I I BRACEFRAME N - '-'-'-'--.-.-.-.- --'-'-'-'- � � I STOR OFp 138 I -`---------- -- - -------- ------------- HOSE RACK(FOIO) I c CASCADE m FILL STATION(FOIC) 14 A618 CORRIDOR O =4 m qv E 135 " CORNER GUARD (SEE INT ELEVS) 9 S A618 N 137 i E� i hl CLEAN I - - - - 136 I D a V-71/4" D I SCBA 137 W I : , it �n S A618 N i E PLYWOOD ON WALL I SEE INT ELEV � l' I HINGED COUNTER Opp OVER CYLINDER VISE j-71 I O ILL] /3 i i -- --- S A618 N SHOP r--�--- i I 134 E - --- �FLAMCAB, WORK F010 � (-BENCH ADJ SHELVING n i D - ;'+—ROLLING CART, FDIC I'il a' I IN EMS $ 2 N 132 ' 23 _- A618 - - - - - - E UP 132 • 3,$„ I-31f2" FEC 5 A618 I� 30 A i biz CORRIDOR E 131 BATTERY CHARGING OUNTER itMULTIOUTLET RACEWAYABV So f��z 133 f ------------- I I 8'-1 1/4" `7 N M ci MECH 133 w Y 2 N I BRACEFRAME O — _ D - ------------ FO___�/ Io ........ -L --•-•-•-•-•-•- -•--•-•-•-• o iv 12 N - -j— - - - - 130E i CLR N i r_FLUSH FLR GRATE ---WPAREADRAIN BEL - --1 V 1 FD t -'---------(---- c- --.- ( ( ( I 10'L SST DRAINED CC ( I I I -J. JEQBAL SINK W/ BF .-. I I 1 I �-HOSEBIBB � W L� I 411 WSST SHELF E E A81 125 ABV _ MAP WALL - - - W SST SH FD) i S�A611 I ( CURTAIN ;I 15 _CORNER GUARD I TRACKABV E A704 (SEE INT ELEVS) 25 1 A I I I 1 L---------------------J I_-- -7,3118" _f -------_—CORNERGUARD (SEE INT ELEVATIONS} TRENCH DRAIN v`2 _FLUSH FLR GRATE W/ - SEE MECH CORNER GUARD AREA DRAIN BEL (SEE INT ELEVATIONS) FLUSH FLOOR GRATE CORNER GUARD (SEE INT ELEVS) - - - - - - - - - BRACE FRAME, TYP SEE STRUCT W 1 A616 E 1 APP BAY S A615 N 130 PROVIDE STRIPING AT APP BAY. LINE LOCATIONS TO BE - MARKED ON SITE W1 TFD FUTURE ELE( MAP. SEE ELE( TRENCH DRAIN TRENCH DRAIN CORNER ;HER GUARD -(SEE (NT i INT ELEVATIONS) (+g �W6-01 Y- JER GUARD INT ELEVATIONS) CORNER WITH AREA DRAIN BEL01 I II i 128 GEAR -WASH I' C) 128 q `HANGING BAR + & SHELF l� I, 129A li I l� I ----- WALL-MTD GEAI GEAR ST( / 29 i l; I ii l' I i, FD is I 'li I (6) 2'-0"D WA OPEN MTL S L m W AIRLOCK 4 BOOT WASH: FL S A617 �N FLR GRATE W1 / DRAIN BEL, TYF 11 TYP A70 - ' � 1 -WALL-MTD TV, NO 703 FOUR -FOLD DOOR STL BOLLARD, TYP A IN OPEN POSITION (TYP) S TATI Z I = Z uu un uu nn un nn uu n° I I uu nu uu nn Uu un nu tin — uu nu un nU un nu nu un nh Un uu ni i r r I I I I 1 322 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 8 2019 LCity of Tukwila UILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019. PERMIT CENTER GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE - SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 20151BC - - - - INTERIOR AIR BARRIER 3 414/19 Permit Revision 1B 12111118 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by LR Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.corn m 2018 Weinstein A+U -These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. Epp REGISTEREI. rAR�C�HIIIT�EC�•'T EDWARDEINSTEIN shington Issue PERMIT SUBMITTAL Date 10/15/2018 Sheet Title ENLARGED FLOOR PLAN LEVEL 1 SOUTH Sheet LA i LU z V Ln LU z Q Co 04 •I• H V w F V ce -J ■ 1� He I I I I i I I I I I I I I I I I I I I I I 2 2 A301 A325 _EXTENT OF REINFORCED COPING FOR LADDER ACCESS TO ROOF STL CANOPY BELOW 2 ROOF ASSEMBLY (3B/A402) - REINFORCE 324 ROOFING IN HATCHED AREA FOR FD DRILLING T-3 5/8" 4'-8 3/8" 10'-3 5/8" ACTIVITIES; PROVIDE SLIP SHEETAND DECKING f�UN:CONDITIONED —ACTIVITIES; SLEEPERS TO PROTECT ROOF MEMBRANE. MECH LOUVERS BOD: TREX SELECT COMPOSITE DECKING ;iaxi A i I�- - P - n F( E) OD PORCH203 \ APPROX LOCATION OF RADIO ANTENNA.M \\ CONFIRM W/ARCy(& ELEC \ CONNECT TO STRUGT IN WALL �\ \ / 6 3'- / \\ 8'-0 4'-4 718" 4'-31/2"• '-3 5/8424 I I I I I I I I 2 A311 I I I I I I 7LADDER INFORCED COPING CCESS TO ROOF I I CRICKETAS NECESSARYAT GUTTER A - - - - - V / DS / 114":V-0" _ q-�. G ° OUTDOOR CONDENSING UNIT \ \\ "� - ON SLEEPERS +PLATFORM % 2112" FIND STL TUBE " _ PER MECH SPEC \ / POSTS AT BASE OF MECH { DRYER VENT REMOVABLE GUARDRAIL SCREEN PER STRUCT,TYP 'li \ ! - ---- 1 .; i GUTTER ROOF VENTILATOR (RV) W/ \ ! I b PREFAB CURB PER MECH, CRICKET, 4 A4 R TYP OF 4 (4-7 -- j \ / TYPATROOFTOP�� \\ EQPT —► i HEAT RECOVERY UNIT ON I V —CONT MTL RAIL CURB BY MFR , (SHOWN W/ HEAVY DASH) , OPEN TO q 1/4':l'-0" 3 MECHANICAL SCREEN APP BAY BELOW X2 3'X5' WALK - -- (MFR: AMERISTAR IMPASSE II MECH PLATFORM 202 ! \\ - PADS, TYP `- RV RIDGE STRONGHOLD W/ 13/8" AIR GAP, BLACK) LO STL&TRANSLUCENT ! \ 1 12'-7" PANEL CANOPY BELOW �12411 OUTDOOR CONDENSING UNIT ON SLEEPERS + PLATFORM SPEC ! \ OAT I PER MECH UARDRAII � % \\?• ! \ DS� Pp 1/4":1'-0" pO M DOWNSPOUT GUTTER DOWNSPOUT - - - - - - - -� - FEC 2- 201 A 0 ) ! \ 330 / ! AT GLAZING !! \\ 1 y 8 8 " 8-0" wa pow zW=a} MTD LADDER W/ I EA„��--� F /! BELGLAZING 330 F ¢ g 0 i Q O' N' W: o002 ^ cr'- ROOF HATCH ABV . -' / \ \\\ STORAGE !/ I i p EFO RV ! \ COMP L._._._._._. .—.—._._�. _. i — — F — — — — — — — — — I 322 2E T.O. COPING T.O. COPING AT BRICK, TY AT MTL PNL, TYP LOPY BELOW 14'4' 14'-3" I I I I I I I I I I I I �t0t I I 1 2.1 2 3 3.1 4 5 EF $I( I ROOF VENTILATOR W/ E HPREFABCURB) PREFAB CURB PER ER MECH SPEC, MECH SPEC TYP OF 2 I I 2 A311 6 7 1 A311 REVIEWED FOR CODE COMPLIANCE APPROVED dUG 08 2019 City of Tukwila BUILDING DIVISION GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEEA701 7 DOOR SCHEDULE - SEE A911 B WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE - SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 20151BC - - - - INTERIOR AIR BARRIER 3 4/4119 Permit Revision 18 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by LR Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstein A+U -These documents have been prepared specifically for the above named project They are not suitable for use on other projects or in other locations without the approval and participation of dre Architect 3300 REGISTERS ARj'CA�HnI`T,�E"C`•'T EDWARD WEINSTEIN State of Washington Issue PERMIT SUBMITTAL Date 10/15/2018 Sheet Title MECH PLATFORM & LOWER ROOF PLAN Sheet 0, r I I I I I 1 1 2.1 2 UPPER ROOF SCALE:118" = V-0' II I I 1 I I 1 I A301 I A311 I I 3 3.1 4 5 6 7 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQD FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE -SEE A91 1 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015IBC INTERIOR AIR BARRIER 18 12/11/18 Design Revisions 1A 12111/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 i Project No. 17001 Designed by LR Drawn by TM Checked by EN Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstein A+U -These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. 3300 REGISTERS ARCHITECT EDWARD WEINSTEIN State of Washington Issue PERMIT SUBMITTAL', Date 10/15/2018 Sheet Title UPPER ROOF PLAN Sheet Alu3 N Ix w z V en w 0 z 00 m 04 in F V F Ine v I I n L-1 I ABBREVIATIONS LEGEND DRAWING INDEX GENERAL NOTES AC AIR CONDITIONING SYMBOL ABBE DESCRIPTION SYMBOL ABBR DESCRIPTION M001 ABBREVS, LEGEND, NOTES & INDEX 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS ACU AIR CONDITIONING UNIT IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL AD ACCESS DOOR, AREA DRAIN = ALIGNMENT GUIDE X M002 MECHANICAL SCHEDULES SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR ADA AMERICANS WITH DISABILITIES ACT # ANCHOR - -- XX DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN M003 MECHANICAL SCHEDULES SYSTEM OPERATION. AAV AFF AIR ADMITTANCE VENT ABOVE FINISHED FLOOR PIPE ELBOW DOWN 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT APPROX APPROXIMATE ----- DIRECTION OF CUTTING PLANE M004 MECHANICAL SCHEDULES SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND ARCH ARCHITECT PIPE ELBOW UP --- SECTION CUT LINE SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE ENGINEER. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING ARV ACID RESISTANT VENT FLANGE M101 MECHANICAL SITE PLAN THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. ARW SH ASHRAE ACID RESISTANT WASTE AMERICAN SOCIETY OF HEATING FLEX CONNECTION SD-X DIFFUSER OR GRILLE TYPE M201 MECHANICAL FOUNDATION PLAN 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM REFRIGERATION AND AIR CONDITIONING ENGINEERS TEE OUTLET UP XXX CFM AMOUNT (CUBIC FEET PER MINUTE) PLANS. BDD BFF BACKDRAFT DAMPER BELOW FINISHED FLOOR V TEE OUTLET DOWN -+- DIRECTION OF FLOW M301 FIRE PROTECTION ABBREVS., LEGEND, NOTES & INDEX 4. DIMENSIONS SHOWN FOR DUCTWORK WITH SOUND LINING SHALL BE NET FREE DIMENSION WITH SOUND LINING INSTALLED. SOUND LINING SHALL BE 1" THICK BOD BOTTOM OF DUCT t AIR VENT M302 FIRE PROTECTION FLOOR PLAN UNLESS OTHERWISE NOTED. BTUH CA BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR ID AAV AUTOMATIC AIR VENT ® OR XX EQUIPMENT ITEM XX M401 LEVEL 1 PLUMBING PLAN 5. PENETRATIONS THROUGH ROOF OR EXTERIOR WALLS SHALL BE SEALED WEATHER TIGHT. PENETRATIONS THROUGH CEILING OR INTERIOR WALLS SHALL BE CD CEILING DIFFUSER LINE, ARCHITECTURAL BACKGROUND SEALED SUBSTANTIALLY AIR TIGHT. BELOW GRADE WALLS OR SLABS SHALL BE SLEEVED AND SEALED WATERTIGHT. CFM CUBIC FEET PER MINUTE 0- BALANCING VALVE M402 MECH PLATFORM AND LOWER ROOF PLUMBING PLAN CIRC CIRCULATING LIGHT LINE, EXISTING 6. CONFINE THE APPLICATION OF FLEXIBLE DUCTWORK TO LOCATIONS INDICATED BY THE CONTRACT DOCUMENTS. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK CO CLEAN OUT -� ®I-- BALL VALVE M501 LEVEL 1 HVAC PLAN SHALL NOT EXCEED SIX FEET. COMB COND COMBUSTION CONDENSATE BUTTERFLY VALVE HEAVY LINE, NEW WORK M502 MECH PLATFORM AND LOWER ROOF HVAC PLAN 7. PROVIDE ALL REQUIRED ELECTRICAL POWER, MOTOR STARTERS AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. CONT CONTINUATION CHECK VALVE 0 ROUND DUCT DIAMETER COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. COORD COORDINATE CLEAN OUT M601 LEVEL 1 PIPING PLAN 8. PROVIDE ALL REQUIRED EQUIPMENT GUARDS AND STRUCTURAL SUPPORT AS RECOMMENDED BY EQUIPMENT MANUFACTURERS TO SUPPORT EQUIPMENT AND COTG CW CLEAN OUT TO GRADE COLD WATER FCO CLEAN OUT - FLOOR X/Y X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION M602 MECH PLATFORM AND LOWER ROOF PIPING PLAN TO ASSURE SYSTEM PERFORMANCE AND SAFE OPERATION. COORDINATE PRIOR TO INSTALLATION. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN DEG DEGREE EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE FIRE RATING WITH THE ARCHITECTURAL DOCUMENTS. DIA DIAMETER N WCO CLEAN OUT - WALL ' 9 � � 'f� 6 M701 MECHANICAL UPPER ROOF PLAN DIM DIMENSION GATE VALVE 9. COORDINATE LOCATION OF ALL THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT WITH THE ARCHITECT. LOCATIONS AS SHOWN THE DRAWINGS ARE FOR DN DOWN EXISTING WORK TO BE REMOVED M807 MECHANICAL LARGE SCALE PLANS REFERENCE ONLY. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL ELEVATIONS. IF NOT SHOWN ON ARCHITECTURAL ELEVATIONS, MOUNT NO HIGHER DOAE DEDICATED OUTSIDE AIR EXHAUST GLOBE VALVE THAN 44" AFF. DOAS DEDICATED OUTSIDE AIR SUPPLY HB OR WH HOSE BIBB OR WALL HYDRANT �i ? - BREAK IN PIPE OR DUCTWORK M802 MECHANICAL DIAGRAMS 10. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. BUILDING AND STRUCTURE IS DESIGNED TO SUPPORT EQUIPMENT, BUT NOT DETAILED TO DS DWG DOWNSPOUT DRAWING 'ro INDIRECT DRAIN M803 MECHANICAL DIAGRAMS 1A ACCOMMODATE EACH AVAILABLE EQUIPMENT CONFIGURATION OR MANUFACTURER. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT E EXISTING T 1/ FLAG NOTE NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. EA EACH, EXHAUST AIR INSTRUMENT TEST CONNECTION M804 MECHANICAL SECTIONS ELEV, EL ELEVATION MODULATING VALVE 11. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. EAT ENTERING AIR TEMPERATURE T PETE'S PLUG (TEST CONNECTION} 1 REVISION NOTE M901 MECHANICAL DETAILS 12. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. EG ESP EXHAUST GRILLE EXTERNAL STATIC PRESSURE - g�iq PLUG VALVE AREA CLOUDED CONTAINS M902 MECHANICAL DETAILS EWT ENTERING WATER TEMPERATURE CHANGES TO DRAWINGS 13. PROVIDE MINIMUM OUTSIDE AIR PER WASHINGTON ADMINISTRATIVE CODE REQUIREMENTS. EXIST EXISTING � SUBSEQUENT TO PREVIOUS ISSUE M903 MECHANICAL DETAILS EXH EXHAUST PRESSURE GAGE 14. SHUT OFF FOR SMOKE CONTROL: PROVIDE SMOKE DETECTORS FOR AUTOMATIC FAN SHUT DOWN IN AIR CONDITIONING UNITS IN ACCORDANCE WITH THE EXP EXPANSION PUMP (DIRECTION SHOWN BY ARROW) -.- DNI ON DUCT OFFSET DOWN IN M904 MECHANICAL DETAILS INTERNATIONAL MECHANICAL CODE (IMC). 2015 WASHINGTON STATE ENERGY CODE F FAHRENHEIT C FC FORWARD CURVED _ - PRESSURE REDUCING VALVE FLOW DIRECTION M905 MECHANICAL DETAILS FCO FLOOR CLEANQUT}IID -► UP UP DUCT OFFSET UP IN FD FIRE DAMPER, FLOOR DRAIN PRESSURE RELIEF VALVE FLOW DIRECTION FDC FIRE DEPARTMENT CONNECTION SITE GLASS .,....__....__.....,. 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE FFE FINISHED FLOOR ELEVATION -R)�-- DUCT WITHOUT SOUNDLINING C403.2.3(1)A,(1)B,(1)C,(2),(3),(4),(5),(7),(8),(9) OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. FLA FULL LOAD AMPS FDIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR p"ic} SOLENOID VALVE SINGLE LINE DUCT W/ INTERNAL LINING 2. PROVIDE DEADBAND BETWEEN HEATING/COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION C403.2.4.1.2 OF THE WSEC OR AS FPM FEET PER MINUTE DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. FT G G FOOT, FEET NATURAL GAS THERMOMETER DUCT WITH INTERNAL LINING ACOUSTICAL LINING 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2.1 OF THE WSEC AND AS GA GAUGE INDICATED ON THE CONTRACT DOCUMENTS. GAL GALLONS - THREE WAY VALVE FLEXIBLE CONNECTION GALV GALVANIZED OR FLEXIBLE DUCT 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED GC LAB GAS COCK TWO WAY VALVE BY SECTION C403.2.8 OF THE WSEC. DUCT TAPE NOT ALLOWED. GPM GRD GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS UNION OR FLEX FLEXIBLE DUCT DUCTWORK STATIC PRESSURE AND SEAL CLASS: GWB HP GYPSUM WALL BOARD HORSEPOWER"} VENTURI FLOW VALVE RA/EA RETURN AIR DUCT/RETURN DUCT UP WATER COLUMN SEAL CLASS HVAC HEATING, VENTILATION AND AIR CONDITIONING --rSt-- WYE STRAINER WITH VALVE Nz TO 3 INCHES SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS HW HOT WATER �Y WYE STRAINER GRILLE ABOVE 3 INCHES SEAL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS HWC HOT WATER CIRCULATION --+fit-- +s© RG RETURN AIR HWG HIGH WALL GRILLE 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8.1 AND C403.2.8.2 OF THE WSEC AND AS DESCRIBED IN SECTION 230700 OF THE HWR HOT WATER RETURN - ��- Rpgp REDUCED PRESSURE -j-> SA SUPPLY AIR OUTLET, SIDEWALL PROJECT MANUAL. HWS HOT WATER SUPPLY BACKFLOW PREVENTER ID INDIRECT DRAIN, INSIDE DIAMETER ® SA SUPPLY AIR DUCT/SUPPLY DUCT UP DUCT TYPE LOCATION R-VALUE IE INVERT ELEVATION DCVA DOUBLE CHECK VALVE ASSEMBLY IH INSTANT HOT WATER DISPENSERS DDCVA DOUBLE DETECTOR CHECK VALVEIN INCH ei RA/EA RETURN AIR OR EXHAUST AIR DUCT SUPPLY/RETURN EXTERIOR R-8, CLIMATE ZONE 4 (INCLUDE KW KW KILOWATT, (1000 WATTS) - RPBP REDUCED PRESSURE APPROVED WEATHERPROOF BARRIER) LEAVING AIR TEMPERATURE --�-- BACKFLOW PREVENTER SD SUPPLY GRILLE OR DIFFUSER R-12 CLIMATE ZONE 5 (INCLUDE LR LINEAR RETURN WITH FUNNEL DRAIN OPEN AREA INDICATED ACTIVE ELEMENTS APPROVED WEATHERPROOF BARRIER) LWG LOW WALL GRILLE (4 WAY IF HATCH IS NOT SHOWN LWT LEAVING WATER TEMPERATURE ® FD FLOOR DRAIN SUPPLY/RETURN/OUTSIDE AIR UNCONDITIONED SPACE R-6 MAX MAXIMUM O LINEAR DIFFUSER MBH 1000 BTU PER HOUR ® FS FLOOR SINK OUTSIDE AIR (<2,800 CFM SUPPLY WITHIN CONDITIONED SPACE (NOT CONSIDERED R-7 (DAMPER AT ENVELOPE MCA MINIMUM CIRCUIT AMPS ---CW--- -CW--- CW COLD WATER EA EXHAUST AIR DUCT/EXHAUST DUCT UP UNIT) PART OF THE BUILDING ENVELOPE) PENETRATION) MFG MANUFACTURER MIN MINIMUM ----HW---- HW HOT WATER EG EXHAUST AIR GRILLE OUTSIDE AIR(>2,800 CFM SUPPLY WITHIN CONDITIONED SPACE (NOT CONSIDERED MUST INSULATE TO ENVELOPE MTG NC MOUNTING NORMALLY CLOSE -----HWC----- HWG HOT WATER CIRCULATION UNIT) PART OF THE BUILDING ENVELOPE) REQUIREMENTS OF CHAPTER C402 NIC NOT IN CONTRACT W W WASTE TRANSITION - RECTANGULAR SUPPLY WITHIN CONDITIONED SPACE R-3.3 NFPA NATIONAL FIRE PROTECTION ASSOCIATION TO ROUND NG NATURAL GAS _--_ V____ V VENT NO NORMALLY OPEN ----0---- VTR VENT THROUGH ROOF +' - RECTANGULAR ELBOW WITH TURNING VANES 6. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.9 OF THE WSEC AND AS DESCRIBED IN SECTION 220700 AND 230700 OF THE PROJECT NT NEUTRALIZATION TANK MANUAL: NTS NOT TO SCALE CWS CWS CHILLED WATER SUPPLY 90'(R/D OR R/W=1.5) OA OUTSIDE AIR MINIMUM PIPE INSULATION THICKNESS OAT OUTSIDE AIR TEMPERATURE - - CWR - - CWR CHILLED WATER RETURN OC OBD ON CENTER OPPOSED BLADE DAMPER FOS FOS FUEL OIL SUPPLY r SYSTEM/TEMP ('F) INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER ORD OVERFLOW ROOF DRAIN - -FOR - - FOR FUEL OIL RETURN 7-"--) 90' ELBOW TAKE -OFF WITH 45' TAPER CONDUCTIVITY MEAN RATING < 1" 1" to 1-1/2" 4" to z 8 OS&Y PH OUTSIDE STEM AND YOLK PHASE HWS HWS HEATING WATER SUPPLY BTU in./(h• ft", F') TEMPERATURE, F < 1-1/2" to < 4 < 8" POC POINT OF CONNECTION - - HWR - - HWR HEATING WATER RETURN 90' CONICAL TAKE -OFF HEATING > 350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 PSI POUNDS PER SQUARE INCH 257-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 PW PRESSURE WASTE RWL RWL RAINWATER LEADER ® CARBON MONOXIDE SENSOR 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 RA RETURN AIR ORL ORL OVERFLOW RAINWATER LEADER 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 RG RETURN GRILLE 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 RH ROOF HYDRANT - - IRS - - RS REFRIGERANT SUCTION 02 CARBON DIOXIDE SENSOR COOLING 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 RL RAIN LEADER RL RL REFRIGERANT LIQUID < 40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 RD ROOF DRAIN SWITCH REF READ REFERENCE REQUIRED C C CONDENSATE DRAIN Q OR THERMOSTAT 7. SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES EXCEPT RG RETURN GRILLE G G NATURAL GAS EQUIP ID#\ TO EQUIPMENT LOCATION WHERE PERMITTED IN SECTION C403.2.4.1 OF THE WSEC. RPM REVOLUTIONS PER MINUTE SS SS SANITARY SEWER QS SENSOR RPBP REDUCED PRESSURE BACKFLOW PREVENTER 8. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM AS REQUIRED BY SECTIONS C403.2.11.3 AND C403.2.14 OF THE WSEC FOR FULL LOAD SA SUPPLY AIR F F FIRE PROTECTION WATER ® HUMIDISTAT EFFICIENCIES. SD SG STORM DRAIN, SUPPLY DIFFUSER SUPPLY GRILLE A A COMPRESSED AIR ® GAS RESET BUTTON 9. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C103.6.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION SHT SHEET PIPE SIZE REDUCTION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A SM SO SHEET METAL SCREENED OPENING _DN PIPE SLOPE DOWN THIS DIRECTION I BDD '- BACK DRAFT DAMPER MINIMUM. SP STATIC PRESSURE PIPE CAP FIRE DAMPER, 10. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS SPECIFIED AND PER SECTION C103.6.2 SPD SPEC STATIC PRESSURE DROP SPECIFICATIONS Q GAS COCK FD WALL OR CEILING 11. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC. TDH TOTAL DYNAMIC HEAD UU TG TRANSFER GRILLE FSD FIRE AND SMOKE DAMPER 12. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING SHALL BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE WSEC. TOD TOP OF DUCT COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, TRAINING, TPD TOTAL PRESSURE DROP REPORTS AND ACCEPTANCE. SUBMIT COMMISSIONING COMPLIANCE CHECKLIST TO BUILDING OFFICIAL UPON COMPLETION. TSP TOTAL STATIC PRESSURE VD VOLUME DAMPER TYP TYPICAL 13. CONTROL SYSTEM SHALL PROVIDE 7 DAY PROGRAMMING AND SETBACK CAPABILITY, OPTIMUM START, THERMOSTAT INTERLOCK AND TEMPERATURE RESET. V VOLT, VENT---- SYSTEM TO COMPLY WITH SECTIONS C403.2.4.2 AND C403.2.4.3 OF THE WSEC. VD VOLUME DAMPER MOD MOTOR OPERATED DAMPER VTR VENT THRU ROOF 14. PROVIDE HOT WATER HEATERS WITH MINIMUM R-10 INSULATION PAD UNDER THE TANK. IN WASTE WB WET BULB TEMPERATURE ® CLEARANCE REQUIREMENT 15. PROVIDE AUTOMATIC SHUTOFF FOR ALL DOMESTIC WATER CIRCULATION PUMPS. SEE ALSO SPECIFICATION SECTION 230900. W/ WITH WC WATER CLOSET 16. RESET HEATING AND COOLING TEMPERATURES AUTOMATICALLY PER SECTION C403.4.4.4 OF THE WSEC. SEE ALSO SPECIFICATION SECTION 230900. WCO WALL CLEAN OUT ® FILTER WIG WATER GAUGE 17. PROVIDE ISOLATION VALVES FOR ALL EQUIPMENT CONNECTED TO FLUID PIPING. WH WALL HYDRANT WHA WATER HAMMER ARRESTER 18. MECHANICAL SYSTEM EQUIPMENT SIZING COMPLIES WITH ENERGY CODE COMPLIANCE LIMITS SECTION C403.2.1 AND C403.2.2. WSEC WASHINGTON STATE ENERGY CODE 19. DAMPERS SHALL COMPLY WITH WSEC C403.2.4.3, INCLUDING DAMPERS INTEGRAL TO HVAC EQUIPMENT, AND SHALL HAVE A MAXIMUM LEAKAGE RATE WHEN TESTED IN ACCORDANCE WITH AMCA STANDARD 500 OF: NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED A. MOTORIZED DAMPERS: 4 CFM/FT2 OF DAMPER AREA AT 1.0 INCH W.G. B. NON -MOTORIZED DAMPERS: 20 CFM/FT2 OF DAMPER AREA AT 1,0 INCH W.G., EXCEPT THAT FOR NON MOTORIZED DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION: 40 CFM/FT2. 20. THE HVAC SYSTEM AND ITS CONTROLS SHALL ALLOW ECONOMIZER OPERATION WHEN MECHANICAL COOLING IS REQUIRED SIMULTANEOUSLY. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD. HIGH -LIMIT SHUTOFF CONTROL FOR AIR ECONOMIZER SHALL BE SET WHEN OUTSIDE AIR TEMPERATURE IS HIGHER THAN 757. 21. ALL DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6 PERCENT OF THE FAN FLOW IF THE DUCT SYSTEM: A. IS CONNECTED TO A CONSTANT VOLUME, SINGLE ZONE, AIR CONDITIONER, HEAT PUMP OR FURNACE; AND B. SERVES LESS THAN 5000 SQUARE FEET OF FLOOR AREA, AND C. HAS MORE THAN 25 PERCENT DUCT SURFACE AREA LOCATED IN ANY UNCONDITIONED SPACE. 22. THE LEAKAGE RATE SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. CODE COMPLIANCE APPROVED AUG 0 8 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 414/19 Permit Revision 1B 12111/18 Design Revisions 1A 12/11/18 Permit Corrections #1 IRev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENe USCH GROUP, INC ,iC0161A11. NIgD Y�FA 8 MEdNHGV. Ef10 (w M6T � 91EET 9111E �I 9'vpilE S19ln0 (20!) J7M06M ice) S/l-014/ FN! In w Z U GREEN Z _ Q m ,P iz833 F`PS ONAL �N�` .yy + H H_ -- _ V of Q D JURISDICTIONAL APPROVALSTANIP Issue MECHANICAL PERMIT 0 UJ Date 7/25/2019 Sheet Title ABBREVS., LEGEND, NOTES & INDEX Sheet fl A00 1 MECHANICAL ELECTRICAL COORDINATION SCHEDULE ITEM NO. EQUIPMENT DESCRIPTION POWER MOTOR CONTROL EQUIPMENT REMARKS VOLTS PH PROVIDED BY INSTALLED BY WIRED BY MECH I ELEC MECH ELEC MECH ELEC AC SPLIT SYSTEM AC INDOOR 208 1 X X X 2 ODU SPLIT SYSTEM AC OUTDOOR 208 1 X X X 2.6 VRF VRF, IDU ODU 208 3 X X X 2 EF EXHAUST FAN 120 1 X X X 2,7 VEF NEDERMAN SYSTEM 268 3 X X X 2 OF DESTRATIFICATION FANS 102 1 X X X 2,7 HRV HEAT RECOVERY VENTILATION 208 3 X X X 2,7 MAU MAKE-UP AIR UNIT 208 3 X X X 2,7 CF CEILING DESTRAT. FANS 120 1 X X 2,7 FSD FIRE SMOKE DAMPERS 120 1 X X X 2,7 MOD MOTOR OPERATED DAMPERS 120 1 X X 2,7 DHWH - 1, 2 HOT WATER HEATER 120 1 X X X 2 DOMESTIC WATER HEAT TRACING TAPE 120 1 X X X 2 AIR AIR COMPRESSOR 208 3 X X X 2 EUH UNIT HEATERS 208 1 X X X 2,4 UH GAS HEATERS 120 1 X X X 2.4 COMPRESSORS DRY SPRINKLER SYSTEM 208 3 X X X 2 FIRE SPRINKLER HEAT TRACING TAPE 120 1 X X X 10 NOTES: -- DISCONNECTS BY ELECTRICAL CONTRACTOR 1. COMBINATION MOTOR STARTER DISCONNECT 2. DISCONNECT SWITCH 3. VARIABLE FREQUENCY DRIVE - VFD 4. LINE VOLTAGE 7-DAY PROGRAMMABLE REMOTE WALL MOUNTED THERMOSTAT 5. DUPLEX PUMPS WITH TWO MOTOR STARTER DISCONNECTS OR ONE STARTER -DISCONNECT WITH ALTERNATOR 6. WEATHERPROOF 7. DISCONNECT AND CONTROL CONTACTOR 8. PROVIDE TWO CIRCUITS FOR CONTROL SYSTEM POWER 9. OPERATE FROM WALL SWITCH. 10. PROVIDE CONTROL AND MONITORING FOR HEAT TRACE ON SPRINKLER PIPING FROM FIRE ALARM PANEL 11. PROVIDE STEP DOWN TRANSFORMER TO 24 V 12. LINE VOLTAGE REMOTE WALL MOUNTED THERMOSTAT 13. PROVIDE SMOKE DETECTION SHUTDOWN AND INTERFACE WITH FIRE ALARM PANEL 14. PROVIDE TIMER SWITCH THAT ALTERNATES BETWEEN INTERMITTENT AND MINIMUM VENTILATION RATES 15. PROVIDE GREENHECK VARIGREEN CONSTANT PRESSURE CONTROL PACKAGED SYSTEM AND ALL NECESSARY ACCESSORIES TO CONTROL OFFICE SPACE BUILDING PRESSURE 16. OPERATE FROM LOCKING WALL SWITCH 17.INTERLOCK RETURN FAN TO ASSOCIATED AHU 18. PROVIDE CONTROL COMPONENTS AS REQUIRED TO MEET SEQUENCE OF OPERATION. 19. CONTROL FROM BUILDING TIME CLOCK. DOMESTIC HOT WATER HEATER AND ACCESSORIES MARK REMARKS DHWH-1, DOMESTIC HOT WATER HEATER, NATURAL GAS FIRED, 150,000 BTUH INPUT RATING, 98% THERMAL EFFICIENCY. DHWH-2 100 GALLON STORAGE CAPACITY, MIN. 170 GPH RECOVERY, 100 DEG F RISE. FURNISH HEATER INSTALLED WITH TEMPERATURE AND PRESSURE RELIEF VALVE, PROVIDE WITH GALVANIZED STEEL SEISMIC STRAP BRACING, HOLD -RITE OR EQUAL, PROVIDE FACTORY DIRECT VENT KIT FOR VENTING AND CONDENSATE NEUTRALIZATION KIT. PROVIDE 120V, 1 PHASE. FIELD FABRICATE 4" HOUSE KEEPING PAD. 3 BASIS OF DESIGN: A.O. SMITH CYCLONE MXI BTH 150. DHWCP DO TIC T W R C PU 5 M, 1 FT H D. 1 HP OV 1 ET BLADDER STYLE EXPANSION TANK. ASME RATED TO 125PSI, 240 F, DRAIN VALVE. BASIS: AMTROL, A.O. SMITH, OR EQUAL. TEMPERING THERMOSTATIC MIXING VALVE. PROVIDE PER ASSE 1070 AT FIXTURE GROUPS AS REQUIRED BY LOCAL AHJ. VALVE SIZED TO MATCH FIXTURE LOAD. BASIS LAWLER, LEONARD, OR BY PRIOR APPROVAL. AW PLUMBING FIXTURE SCHEDULE FIXTURE MARK SYMBOL SERVICE CONNECTION FIXTURE DESCRIPTION REMARKS WASTE VENT CW HW GRADE GCO 0 - - - - ADJUSTABLE CLEAN OUT WITH POLYPROPYLENE CLEANOUT PLUG WITH THREADED BRASS INSERT. PROVIDE PVC TO CAST IRON HUB - CLEANOUT BASIS: SIOUX CHIEF 851. FLOOR 2 2 3/8 12 x12 CAST IRON FLOOR RECEPTOR, S DEPTH, PORCELAIN FINISH, DOME STRAINER. PROVIDE WITH HALF GRATE. COORDINATE SINK FS-1 a - GRATING WITH DRAINS TERMINATING OVER RECEPTOR. BASIS: ZURN SANI-FLOOR Z1901 NOTE 1 FLOOR FD-1 2" 2" 3/8" FD-1: GENERAL ROOM FLOOR DRAIN, 6 DIAMETER TYPE B STRAINER, CAST IRON BODY, ADJUSTABLE COLLAR, NICKEL BRONZE DRAIN FD-2 ® - ADJUSTABLE STRAINER HEAD, TRAP PRIMER CONNECTION. BASIS: ZURN Z415B. FD-2: SAME AS FD-1 BUT WITH FUNNEL CONNECTION. NOTE 1 TRENCH 4" 2 - - HEAVY DUTY DIN 19580 LOAD CLASS C TRENCH DRAIN. RATED AT 56,000LBS - 1,162PSI. 13/16'X 1/2 LONGITUDINAL STAINLESS DRAIN TD-1 STEEL SLOT BAR GRATE. BASIS: SMITH MFG. 9870-430-SSM NOTE 1 0 TROUGH 4" 2" - - POLYPROPYLENE TROUGH DRAIN WITH BOTTOM OUTLET AND INTEGRAL LINT FILTER. PROVIDE WITH VENTED, PRIMED P-TRAP DRAIN TD-2 AT SEWER CONNECTION. INSTALL FLUSH WITH FLOOR. 30 GALLON, 4.0 CUBIC FT. CAPACITY. NOTE 1 0 BASIS: H-M COMPANY COMMERCIAL LAUNDRY EQUIPMENT. AREA AD-1 2' 2" 3/8" - AREA DRAIN, SQUARE TOP, CAST IRON GRATE, CAST IRON BODY WITH BOTTOM OUTLET, SEEPAGE PAN, MEMBRANE FLASHING CLAMP DRAIN 0 AND FRAME. BASIS: ZURN Z609 NOTE 1 SE - 4" RA TO C INI ND -F ZE E GR AC OW VE Z SIN . BIB HB-1 BASIS: ZURN MODEL Z1300 - HOSE - - 3/4" - EXPOSED, LEAD FREE, ANTI SIPHON, MODERATE CLIMATE WALL HYDRANT, EXTERNAL VACUUM BREAKER WITH 3/4 HOSE CONNECTION, BIB HB-2 PERMANENTLY FASTENED WHEEL TYPE HANDLER. ZURN Z1341XL OR ACCEPTED EQUAL. - HOSE 1/4 - 3/4" - EXPOSED, NON -FREEZE POST HYDRANT. GALVANIZED STEEL CASING AND CAST ALUMINUM CASING GUARD. BRONZE PARTS AND SEAT. BIB HB-3 �- PROVIDE VACUUM BREAKER AND WHEEL HANDLE.PROVIDE WITH CONCRETE PROTECTIVE BASE.DRAIN PER MANUFACTURER'S INSTRUCTIONS. - ROOF 1/4 - 3/4 - ROOF HYDRANT: EXPOSED, NON -FREEZE ROOF HYDRANT, BRONZE INTERIOR PARTS, BRONZE VALVE HOUSING WITH 1/8" DRAIN PORT HYDRANT RH-1 IN HOUSING, DURA-COATED CAST IRON ROOF SUPPORT SLEEVE WITH WIDE ANCHORING FLANGE AND CLAMP COLLAR. - PROVIDE WITH BACKFLOW PREVENTER VALVE. BASIS: ZURN Z1388 OR ACCEPTED EQUAL. BACKFLOW PREVENTER: 3/4" DUAL CHECK VALVE, TO PROTECT AGAINST BACK SIPHONAGE AND BACK PRESSURE BASIS: ZURN MODEL 700 OR ACCEPTED EQUAL. HOSE REEL - - - - HIGH CAPACITY HOSE REEL WITH HEAVY DUTY STEEL CROSS SUPPORT. HOSE: 3/8 ID AND 1/2" OD, 10OFT, RATED AT 300 PSI. AIR HR-A BASIS: COXREEL SLP- 5100. - PROVIDE ADDITIONAL STRUCTURAL SUPPORT AS REQUIRED FOR CEILING AND WALL MOUNTED INSTALLATIONS. HOSE REEL - - 3/4" - HIGH CAPACITY HOSE REEL WITH HEAVY DUTY STEEL CROSS SUPPORT. HOSE: 3/4" ID AND 1-1/16 OD, 10OFT, RATED AT 300 PSI. WATER HR-W BASIS: COXREEL SLP- 5100. - PROVIDE ADDITIONAL STRUCTURAL SUPPORT AS REQUIRED FOR CEILING AND WALL MOUNTED INSTALLATIONS. WALL 2" 2" 3/4" 3/4" 20GA. KNOCKOUTS IN TOP, BOTTOM, AND SIDES. INSTALL WITH 1/4 TURN BALL VALVES, DRAIN, AND HAMMER ARRESTERS. BOX WB-1 o GUY GREY OR ACCEPTED EQUAL. - WALL - - 1/2" - 20GA. KNOCKOUTS IN TOP, BOTTOM, AND SIDES. INSTALL WITH SINGLE 1/4 TURN BALL VALVE AND HAMMER ARRESTER. BOX WB-2 GUY GREY OR ACCEPTED EQUAL. - LAVATORY L -1 1-1/2 1-1/2" 1/2" 1 2 WALL MOUNTED SINGLE CENTER HOLE LAVATORY, VITREOUS CHINA FOR CONCEALED CARRIER, WITH OVERFLOW. ADA COMPLIANT. BASIS: KOHLER K-2084. - FAUCET, DELTA MODERN FAUCET 559LF-PP. 0.5 GPM MAX AERATOR, WITH MIXING VALVE, TEMPERING D VALVE AND SELF SUSTAINING POWER SYSTEM. BASIS: CHICAGO FAUCETS 116.978.AB.1 TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTI -TURN ANGLE STOP W/LOOSE KEY. STAINLES STEEL. BRAIDED FLEXIBLE RISERS. PROVIDE INSTALLED WITH CONCEALED ARM CARRIER. LAVATORY L -2 1-1 2 1-1/2" 1/2" 1/2- VITREOUS CHINA, WITH OVERFLOW.UNDERMOUNT, RECTANGULAR BASIN. ADA COMPLIANT.NO FAUCET HOLES. KOHLER CAXTON K-20000 FAUCET. SINGLE HANDLE, ADA COMPLIANT. DELTA MODERN FAUCET 559LF-PP. TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. NOTE 4 SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTI -TURN ANGLE STOP W/LOOSE KEY. SS BRAIDED FLEXIBLE RISERS. BOOT WASH BW-1 - - 3/4" 3 4 CHROME PLATED WASHDOWN STATION WITH 3/4- MIXING VALVE, THERMOMETER, 50 HOSE, REAR TRIGGER SS WATER GUN. BRASS FAUCET �- THERMOMETER TEE. SS THERMOMETER, 0-200 DEG. F. RANGE. 3/4" INLET SWIVEL HOSE WITH SUPPORT RACK. 10.6 GPM FLOW. B S OF ESI • T RA AND ON WO MV- 71- CW. ROOF DRAIN RD/ORD - - - - COMBINATION ROOF DRAIN AND OVERFLOW ROOF DRAIN WITH LOW DOME. CAST IRON BODY, CAST IRON CLAMP DEVICE, AND OVERFLOW INTEGRAL DOME GUARD, DOME STRAINER, SUMP RECEIVER AND UNDERDECK CLAMP. ZURN Z164 OR EQUAL. SE CE -1 2 4 3 S VICE K: F OR UN 10 EP, E-P E M DED NS CTIO THE OPLA CS SIN INC E I GRA Y SW o OLD DRA AS BLY. SHAL MEE NSI ECI TIO 17 - 01 OLO : WHI MU E 6 OR CEP EQ - FAUCET. WALL MOUNTED FAUCET WITH VACUUM BREAKER AND BUCKET HOOK. CHICAGO 897-CP OR ACCEPTED EQUAL SERVICE SS-2 3" 2 3/4" 3/4" SERVICE SINK: FLOOR MOUNTED 10 DEEP, ONE-PIECE MOLDED CONSTRUCTION, THERMOPLASTICS BASIN TO INCLUDE INTEGRALLY SINK MOLDED DRAIN ASSEMBLY. SHALL MEET ANSI SPECIFICATION Z 124-2017. COLOR: WHITE. MUSTEE 65M OR ACCEPTED EQUAL. - FAUCET. WALL MOUNTED FAUCET WITH VACUUM BREAKER AND BUCKET HOOK. CHICAGO 897-CP OR ACCEPTED EQUAL SHOWER SH-1 2 2 3 4 3 4 SHOWER STALL, 63 W X37-1/2"D X79-1 2 H, WHITE COLOR. BASIS: FIBER-FAB MODEL 638F. TRIM: METAL AND BRASS SINGLE HANDLE HAND-HELD SHOWER SYSTEM. CHROME PLATED FINISH. PROVIDE WITH PRESSURE BALANCING CYCLE VALVE, SLIDE BAR, DROP ELL, NOTE 3 VACUUM BREAKER, 69 IN. METAL HOSE AND MOUNTING HARDWARE. FLOW: 1.5 GPM WATERSENSE CERTIFIED. ADA COMPLIANT. BASIS: MOEN T8346. SHOWER DRAIN: 6" ROUND, CHROME PLATED GRID STRAINER. ZURN 415 OR ACCEPTED EQUAL. SHOWER SH-2 2 2 3/4- 3/4' BARRIER -FREE ROLL -IN TYPE FIBERGLASS SHOWER STALL WITH GRAB BARS AND FOLD DOWN SEAT. 63"W X37-1/2"D X79-1/2"H, WHITE COLOR. BASIS: FIBER-FAB MODEL 63BF. TRIM: METAL AND BRASS SINGLE HANDLE HAND-HELD SHOWER SYSTEM. CHROME PLATED FINISH. PROVIDE WITH PRESSURE BALANCING CYCLE VALVE, SLIDE NOTE 3 BAR, DROP ELL, VACUUM BREAKER, 69 IN. METAL HOSE AND MOUNTING HARDWARE. FLOW. 1.5 GPM. WATERSENSE CERTIFIED. ADA COMPLIANT. BASIS: MOEN T8346. SHOWER SH-3 - - 3/4" 3/4" SHOWER VALVE, HEAD AND WAND: SHOWER AND HAND SHOWER SYSTEM WITH LEVER HANDLES, INTEGRAL SERVICE STOPS AND CHECKS. THERMOSTATIC MIXING VALVE: LEONARD TEMPERING VALVE, LEAD FREE, ASSE 1070 LISTED. TEMPERATURE AND PRESSURE BALANCED MIXING VALVE WITH ADJUSTABLE SCREW LIMIT HANDLE TURN. SHOWER WAND WITH SLIDE BAR FOR HAND SHOWER, 30". ODIVERTER CONTROL WITH LEVER HANDLE. IN LINE VACUUM BREAKER, FLEXIBLE METAL HOSE. INSTITUTIONAL SHOWER HEAD, 1.5 GPM NOTE 3 MAXIMUM FLOW RATE. LISTED ADA COMPLIANT. PROVIDE VANDAL RESISTANT ESCUTCHEON SCREWS ANCHOR PLATE, AND ALL INSTALLATION ACCESSORIES. BASIS: MOEN T8346, OR ACCEPTED EQUAL. DRAIN: SAME AS FLOOR DRAIN FD-1. SINK S-1 2 1-1/2 1/2- 1/2 UNDERMOUNT 18 GAUGE 304 STAINLESS STEEL SINK.SINGLE BOWL. PUNCHED FOR SPECIFIED FAUCET. ELKAY ELUH28161OPD. INCLUDE LKPD1 PERFECT DRAIN AND STRAINER, AND ALL MOUNTING ACCESSORIES. PROVIDE WITH INSTANT HOT WATER DISPENSER. BASIS OF DESIGN: INSINKERATOR F-H3300. FAUCET: SINGLE HOLE, SINGLE HANDLE DECK MOUNT. 360 DEG. GOOSENECK SPOUT. 2 1.8 GPM . CERAMIC CARTRIDGE. DELTA TRINSIC 9159-DST PROVIDE WITH KITCHEN AIR GAP. SINK S-2 2 1-1/2- 1/2" 1/2" 304 SERIES SS HAND WASH-UP SINK WITH 7" HIGH BACKSPLASH. FURNISH WITH WALL HANGER AND SS BRACKETS. BASIS: ELKAY. FAUCET: SINGLE HOLE HYTRONIC GOOSENECK SINK FAUCET WITH DUAL BEAM INFRARED SENSOR AND SELF-SUSTAINING POWER SYSTEM. 5-1/4" GOOSENECKSPOUT, DUAL SUPPLY FOR HOT AND COLD WATER SERVICE. 1.0 GPM AERATOR WITH 15-SECOND CYCLE TIME. BASIS: CHICAGO FAUCETS 116.934.AB.1 TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTI -TURN ANGLE STOP W/LOOSE KEY. STAINLES STEEL BRAIDED FLEXIBLE RISERS. SINK S-3 3" 2" 1/2 1/2" STAINLESS STEEL UTILITY SINK, 16 GAUGE, 14 DEEP. 4" BACKSPLASH, ADJUSTABLE BULLET FEET. BOWL: 30 L X 18" W. OVERALL DIMENSIONS: 33" L X 23" W. WITH MATCHED 8" SWING SPOUT DECK MOUNTED FAUCET. C BASKET DRAIN AND INSTALL KIT INCLUDED. BASIS OF DESIGN: GRIFFIN LT.138.228. DECON S-4 2" 1-i/2" 1/2" 1/2" CUSTOM, EXTENDED LENGTH AND DEPTH, STAINLESS STEEL SCULLERY TYPE WALL HUNG SINK WITH BACKSPLASH. 14 GAUGE SINK TYPE 304 STAINLESS STEEL, SATIN 5K FINISH. REFER TO DRAWINGS FOR ARRANGEMENT AND DIMENSIONS OF SINK AND TRIM. _.,., ._,...._ TRIM: 12" WALL MOUNTED SWING NOZZLE FAUCET WITHI STREAM REGULATOR OUTLET TWO HANDLES. HAND SPRAYER: 1.4 GPM SPRAY VALVE WITH 44" FLEXIBLE STAINLESS STEEL HOSE WITH SPRING AND SPRAY PROVIDE WITH EYEWASH. FIELD VERIFY LOCATION WITH OWNER. BASIS: HAWS 7360 PROVIDE EYEWASH WITH TEMPERED WATER. TEMPERING VALVE BY LEONARD OR WATTS LOCATED AT SINK. CONTROL: KNEE CONTROL WITH WALL SUPPORT. TRIM AS MANFACTURED BY T AND S BRONZE WORKS. SINK S-5 2" 1-1/2" 1/2" 1/2" BAR SINK, STAINLESS STEEL, UNDERMOUNT. 15"X15"X6" DEEP. ADA COMPLIANT. ELKAY ELUHAD121255. PROVIDE WITH FAUCET DELTA TRINSIC T3559LF-WL. TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. ® SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN. MULTI -TURN ANGLE STOP W/LOOSE KEY. STAINLES STEEL. BRAIDED FLEXIBLE RISERS. DRINKING 1-1 2 1-1 2 1/2 - BOTTLE FILLING STATION, WITH GREEN CHILLER, FILTERED, 8 GPH, STAINLESS STEEL FINISH. FRONT AND SIDE ACTIVATED BUBBLER. FOUNTAIN/ DFB-1 ELECTRONIC BOTTLE FILLER SENSOR. 115V/60HZ, 260W. 1.1 GPM FLOW RATE. 3000 GALLON CAPACITY FILTER � BOTTLE FILLING 50 DEGREE DRINKING WATER. SHALL MEET ADA GUIDELINES. BASIS: ELKAY EZH2O LZSSWSLP OR APPROVED EQUAL. STATION KOHLER BARDON K-4904-ET, HIGH EFFICIENCY URINAL, VITREOUS CHINA, WHITE, WASHOUT, TOP SPUD, 0.125 GPF, URINAL U-1 2" 2" 1" - ADA COMPLIANT.FLUSH VALVE: KOHLER K-13520, 0.125 GPF, EXPOSED, 3/4" TOP SPUD. C Y R E EWED FOR REV WATER WC-1 4 2 1--1/4 - WALL -MOUNTED VITREOUS CHINA TOILET, ELONGATED BOWL. 1.6 1.1GPF FLUSH VALVE. 1.27 AVG GPF CODE OMPLIANC CLOSET ADA COMPLIANT KOHLER KINGSTON BOWL K-4325. COORDINATE WITH ARCHITECT FOR COLORS/FINISHES. APPROVED ED 3 FLUSH MECHANISM: DUAL -FLUSH, CHROME PLATED CLOSET FLUSHOMETER SLOAN WES-111. PROVIDE EXTRA HEAVY-DUTY WATER CLOSET CARRIER, RATED FOR 750 LB. MIN. LOAD. ZURN Z1203 OR APPROVED EQUAL. 'A JG 08 2019 WATER WC-2 4" 2 1-1/4" - SAME AS WC-1 AB VE, M UNTED TO CURRENT ADA CCESSI LE ST NDAR REQUIREME TS. CLOSET ED C4 of Tukwila OIL/WATER 4 2 - - OIL WATER SEPARATOR WITH ADJUSTABLE FRAME COVER. 8 GPM DESIGN FLOW RATE. 2*-0" STATIC WATER DEPTH. SEPARATOR OWS BASIS OF DESIGN OLDCASTLE PRECAST 253-SA-125 PLUMBING NOTES AND REMARKS: RECEIVED GENERAL: EXTEND AND CONNECT PIPING TO ALL PLUMBING FIXTURES, FURNISH COMPLETE, FUNCTIONAL SYSTEM. CITY OF TUKWIL 1. PROVIDE TRAP PRIMERS PIPED TO WATER SUPPLY. 2. PROVIDE WITH GARBAGE DISPOSAL AND INSTA-HOT HOT WATER TAP. AUG 01 2019 3. PROVIDE WITH ADDITIONAL SLIDE -BARS FOR SHOWER. LOCATE ONE 90-DEG FROM THE MAIN BAR AND PROVIDE SECONDARY "HIGH" MAIN BAR. REFER TO SPECIFICATIONS FOR MORE INFORMATION. WASOMM 4. PROVIDE WITH A LIFT -ANT -TURN STYLE "STOPPER" AT TAIL PIECE. INTEGRAL STOPPER FUNCTION INSTEAD OF TRADINATIONAL POP-UP. PERMIT CENTER 3 4/4/19 Permit Revision 113 12111/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP. INC ICpmIG{I. Nmp wo�0 a IEgVtAG1L EIIWaFPND (20U6)3fe-OCIY (1011SIIOiT AIRZMTML a MIS (S) 3T0-CN1 FA JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL SCHEDULES Sheet M002 I Vi, VRF INDOOR UNIT SCHEDULE MARK AREA SERVED DESIGN CONDITIONS BASIS OF DESIGN NOMINAL COOLING MBH NOMINAL HEATING CAPACITY MBH NOMINAL TOTAL SUPPLY CFM DESIGN TOTAL SUPPLY CFM AREA OCCUPANTS MIN. OUTSIDE AIR CFM EXTERNAL STATIC IN. W.G. MODEL NUMBER VOLTS/ PHASE ELECTRICAL MCA/MFS WEIGHT LBS. REF LINES REMARKS LIQUID IN GAS IN IDU - 1 COMM - SEE AC UNIT SCHEDULE 7 IDU - 2 BUNK 8 9 320 - 414 320 50 1 30 0.0 PKFY-P08NHMU-E2 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1 4 1 2 1,2 IDU - 3 BUNK 8 9 320 - 414 320 50 1 30 0.0 PKFY-P08NHMU-E2 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1 4 1 2 1,2 IDU - 4 BUNK 8 9 320 - 41 320 50 1 30 0.0 PKFY-P08NHMU-E2 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1 4 1 2 1,2 IDU - 5 BUNK 8 9 320 - 41 320 50 1 30 0.0 PKFY-PO8NHMU-E2 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1 4 1 2 1,2 IDU - 6 BUNK 8 9 320 - 41 320 50 1 30 0.0 PKFY-PO8NHMU-E2 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1 4 1 2 1,2 IDU - 7 BUNK 8 9 320 - 41 320 50 1 30 0.0 PKFY-P08NHMU-E2 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1 4 1 2 1,2 IDU - 8 COMMON AREA ADJOINING BUNKS 12 14 94 - 60 500 420 6 55 0.0 PLFY-P12NCMU-ER4 208 1 .39 MCA 208 VOLT, 15 MOCP 60.0 1 4 1 2" 1,2 IDU - 9 COMMON AREA ADJOINING BUNKS 12 14 #94 - 60 500 NOTE 6 NOTE 6 - 0.0 PLFY-P12NCMU-ER4 208 1 .39 MCA 208 VOLT, 15 MOCP 60.0 1 4 1 2" 1.2 IDU - 10 LAUNDRY- ANITOR, BATH 36 40 812-1165 800 420 8 600 0.4 PEFY-P36NMAU-E 208 1 3.33 MCA 208 VOLT, 15 MOCP 110.0 3 $ 5 8 1,2 IDU - 11 OFFICES AND LOBBY 24 27 477-671 600 620 6 67 0.4 PEFY-P24NMAU-E2 208 1 2.25 MCA 208 VOLT, 15 MOCP 100.0 3 8 5 8 1,2 IDU - 12 KITCHEN 36 40 812-1165 1000 620 43 252 0.4 PEFY-P36NMAU-E 208 1 3.33 MCA 208 VOLT, 15 MOCP 110.0 3 8 5 8" 1,2 IDU - 13 PHYSICAL TRAINING 36 40 812-1165 1000 450 18 387 0.4 PEFY-P36NMAU-E 208 1 3.33 MCA 208 VOLT, 15 MOCP 110.0 3 8 5 8" 1,2 SUM 204 228 2830 1541 NOTE: A . EXTERNAL STATIC PRESSURE ALLOWS FOR DUCTWORK AND FILTERS, UNIT MANUFACTURER TO ADD ALLOWANCE FOR WET COIL. B . COIL CONDITIONS: COOLING 80/67 'F EAT DB/WB, 957 OUTDOOR DB; HEATING: 707 EAT DB, 43F OUTDOOR WS REMARKS: 1. BASIS OF DESIGN: MITSUBISHI MULTI CITY 5. CONSTANT VOLUME FAN COIL 2. PROVIDE WITH ATTACHMENT AND MOUNTING ACCESSORIES COMPLETE. 6. IDU-8 AND IDU-9 SHARE THE COMMON AREA 3. PROVIDE WITH LONG LIFE FILTER, PLENUM WITH FILTER SLIDE, FACTORY INTERNAL DRAIN PUMP; MERV 8 FILTER. 7. REFER TO AIR CONDITIONING UNIT SCHEDULE. 4. CONSTANT VOLUME MIXING SECTION HEAT RECOVERY VENTILATOR SCHEDULE DESIGN CONDITIONS BASIS OF DESIGN MARK AREA SERVED TOTAL CFM EFFICIENCY, PERCENT, TEMPERATURE MIN. OUTSIDE AIR CFM EXTERNAL STATIC IN. W.G. MODEL NUMBER KW VOLTS/ PHASE CURRENT INPUT, AMPS WEIGHT LBS. REMARKS HRV -1 ILAUNDRY, BATH 600 70 600 .5" LGH-F600 0.65 230 1 3.0 250.0 1.2 HRV -2 1OFFICE. GREAT ROOM, PT 1 875 1 70 955 1 .5" 1 LGH-F1200 1.3 1 230 1 1 6.0 1 500.0 1 1,2 HRV -3 IBUNKS 300 1 65 180 1 .5" 1 LGH-F300 0.3 1 230 1 1.4 1 150.0 1,2 SUM 1 1 1,775.0 1 1,555 NOTE: A . AIR TO AIR HEAT RECOVERY VENTILATOR, LOSSNAY OR ACCEPTED EQUAL. REMARKS: 1. BASIS OF DESIGN: LOSSNAY 2, FILTER TYPE: MERV 13 VRF OUTDOOR UNIT SCHEDULE MARK REMARKS AIR COOLED OUTDOOR UNIT. 240 MBH NOMINAL COOLING CAPACITY, 95' DB ENTERING AIR, 80' 67F DB WB INDOOR. 270 MBH NOMINAL HEATING CAPACITY, 43' WB ENTERING AIR, VRF-ODU 70 DEGREE DB INDOOR. 42 MCA (EACH OF 2 MODULES), 208/230 VOLT, 3 PHASE INVERTER DRIVEN SCROLL COMPRESSOR, R410A REFRIGERANT, 11.7 EER, 18 IEER, 3.41 COP 1500 POUNDS NET WEIGHT. MITSUBISHI CITY MULTI PURY-P-240TSLMU-A. PROVIDE WITH TWINING KIT, JOINT KIT, LOW AMBIENT, SNOW AIL GUARDS AND BASE PAN HEATER. BRANCH CIRCUIT CONTROLLER SCHEDULE MARK BRANCH IRCUIT CONTROLLER. CONTROLLER rEK 208/230 VOLT, 1 PHASE. R410A REFRIGERANT, 13 PORTS, 150 POUNDS. BC-1 CITY MULTI: CMB-P1013NU-GA. CEILING FAN SCHEDULE ELECTRICAL SIZE WEIGHT MARK VOLT PH WATTS DIAMETER LBS REMARKS 120/1 100 72 INCHES 40 CEILING SUSPENDED DESTRATIFICATION FAN. CF-1 PROVIDE WITH WALL MOUNTED REMOTE, COMBO CF-2 SPEED AND DIRECTION CONTROL. CF-3 FINISH PER ARCHITECT. OVERALL INSTALLATION CF-4 HEIGHT PER ARCHITECT, BASIS OF DESIGN: DESIGN: HUNTER HFC 72 OUTSIDE AIR HEAT RECOVERY VENTILATION UNIT, RHRV SECTION REMARKS SUPPLY FAN FAN WALL, PLUG AIRFOIL FAN. FAN 18 WHEEL DIAMETER, 3500 RPM MAXIMUM SECTION DIRECT DRIVE, 2.3 HP, 208 VOLT, 3 PHASE. 1900 CFM, 3" STATIC PRESSURE, WITH VFD. EXHAUST FAN FAN WALL, PLUG AIRFOIL FAN. FAN 1$ WHEEL DIAMETER, 3500 RPM MAXIMUM SECTION DIRECT DRIVE, 2.3 HP, 208 VOLT, 3 PHASE. 1400 CFM, 3" STATIC PRESSURE, WITH VFD. ELECTRICAL FACTORY MOUNTED STARTERS AND DISCONNECTS. SINGLE POINT POWER CONNECTION. 208 VOLT, 3 PHASE, 185 MCA, 200 MOCP HEATPUMP TOTAL COOLING CAPACITY 77 MBH, SENSIBLE CAPACITY 65 MBH, DX COIL, R410A SECTION REFRIGERANT, TOTAL HEATING CAPACITY 60 MBH, 12.2 EER. BACKUP ELECTRIC RESISTANCE BACKUP HEATING SECTION. 30 KW, 6 STAGE, SCR CONTROL HEATING SECTION HRV ENERGY WHEEL RECOVERY. 208 VOLT, 3 PHASE. SENSIBLE EFFICIENCY OF 827 INCLUDE BYPASS DAMPERS & RECIRCULATION DAMPER FOR ECONOMIZER OPERATION ISOLATION FAN AND MOTOR RESILIENTLY ISOLATED FROM THE FAN CABINET. DAMPER PROVIDE EXHAUST HOOD WITH BIRD SCREEN. PROVIDE BYPASS SECTION TO FURNISH SECTION ECONOMIZER COOLING WHEN HEAT RECOVERY IS NOT REQUIRED. THE OUTDOOR AIR SUPPLY AND THE EXHAUST OUTLET SHALL BE PROVIDED WITH CLASS to MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEMS OR SPACES ARE NOT IN USE OR DURING UNOCCUPIED PERIODS PER SEC C403.2.4.3. FILTERS 2 PLEATED, MERV 8. 0.54 FILTER PRESSURE DROP FOR OA AND RA PRIOR TO WHEEL CABINET PERFORATED GALVANIZED SHEETMETAL INNER LINER IN FAN SECTIONS, SOLID OUTER PANEL 2" THICK, 3 POUND DENSITY ACOUSTICAL INSULATION. MINIMUM OF 6" BASE RAIL FINISH IN STANDARD FACTORY ENAMEL. WEIGHT 3000 POUNDS, VERIFY WITH MANUFACTURER ACCESSORIES 14 INSULATED CURB AND ALL MOUNTING ACCESSORIES. ACCESS ALL ACCESS FROM SIDE OF UNIT. REFER TO MECHANICAL DRAWINGS. INSTALLATION REFER TO MANUFACTURERS WRITTEN INSTRUCTIONS AND CONTRACT DOCUMENTS. SMOKE NOT REQUIRED. DETECTION MANUFACTURER BASIS FOR DESIGN: DAIKIN. ALTERNATES AS ACCEPTED BY PRIOR APPROVAL. IN eIM EXHAUST FAN SCHEDULE SP WEIGHT ELECTRICAL MARK SERVES CFM IN.W.G. LBS SONES REMARKS WATTS HP VOLTS PHASE EF-1 EMS AND 500 0.38 75 3.0 250 115 1 DIRECT DRIVE CABINET EXHAUST FAN WITH ECM MOTOR AND SPEED CONTROL FOR MECH/ AIR BALANCING. BASIS OF DESIGN: GREENHECK CSP A900. SPRINKLER EF-2 CORRIDOR 1100 0.38 90 4.0 500 115 1 DIRECT DRIVE CABINET EXHAUST FAN WITH ECM MOTOR AND SPEED CONTROL FOR AND SCBA AIR BALANCING. BASIS OF DESIGN: GREENHECK CSP A1750 EF-3 SHOP 150 0.38 25 2.5 50 115 1 DIRECT DRIVE CABINET EXHAUST FAN WITH ECM MOTOR AND SPEED CONTROL FOR AIR BALANCING. PROVIDE WITH BACKDRAFT DAMPER. BASIS OF DESIGN: GREENHECK CSP A790 EF-4 MECH 700 0.38 50 2.0 350 115 1 DIRECT DRIVE CABINET EXHAUST FAN WITH ECM MOTOR AND SPEED CONTROL FOR PLATFORM AIR BALANCING. BASIS OF DESIGN: GREENHECK CSP A700 STORAGE EF-5 STORAGE 300 0.38 50 2.0 125 115 1 DIRECT DRIVE CABINET EXHAUST FAN WITH ECM MOTOR AND SPEED CONTROL FOR AIR BALANCING. BASIS OF DESIGN: GREENHECK CSP A410 EF-6 APP BAY 4500 0.25 375 6.0 .75 208 3 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, FACTORY CURB, AND VAR] -GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK G 300 OR ACCEPTED EQUAL. EF-7 KITCHEN 900 1.25 100 14.6 1/3 HP 115 1 DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUST FAN WITH MOTOR OPERATED HOOD DAMPER, FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. (RESIDENTIAL) BASIS OF DESIGN: GREENHECK CUE 121 VG OR ACCEPTED EQUAL. EF-8 ELECTRICAL 300 0.38 30 5.0 .25 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. B 0 SI GR EC 0 G C D A HEAT PUMP UNIT SCHEDULE EXT. COOLING HEATING STATIC NOMINAL NOMINAL WEIGHT, ELECTRICAL MARK CFM PRES. BTUH BTUH SEER HSPF LBS. DESCRIPTION MCA I MOCP I VOLT I PHASE IDU-1 629 0.0 22,500 26,600 18 8.5 50 1 - 208 1 MITSUBISHI MSZ-HE24NA, WALL MOUNTED INDOOR UNIT, WITH REFRIGERANT LINE KIT, INDOOR 230 REMOTE MOUNTED THERMOSTAT. PROVIDE MATCHING OUTDOOR UNIT OR ACCEPTED EQUAL. PROVIDE WITH CONDENSATE PUMP. ODU-1 OUTDOOR - 18 8.5 200 17.1 20 208 1 MITSUBISHI MUZ-HE24NA OUTDOOR CONDENSING UNIT OR ACCEPTED EQUAL. 230 GAS UNIT HEATER SCHEDULE MARK ELECTRICAL CAPACITY WEIGHT LBS REMARKS INPUT I OUTPUT FLA VOLT I PHASE MBH MBH UH-1 UH-2 4.6 115 1 200 166 250 MECHANICALLY INDUCED SEPARATED COMBUSTION, FAN POWERED NATURAL GAS FIRED UNIT HEATER, WITH DIRECT SPARK IGNITION. 409 STAINLESS STEEL HEAT EXCHANGER. VERTICAL DOUBLE WALL COMBUSTION. 83% THERMAL EFFICIENCY. AIR AND VENT TERMINAL KIT WITH ROOF THIMBLE. DIRECTIONAL LOUVERS.HANGER KIT. REZNOR UDAS-200 OR ACCEPTED EQUAL. ELECTRIC UNIT HEATER SCHEDULE SERVES ELECTRICAL DATA MARK WATTS VOLTS PHASE I ACCESSORIES EUH-1 STORAGE 138 2000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- SCBA 137 CONTAINED THERMOSTAT, SET TO 68F. PROVIDE WITH ALL GEAR STORAGE 129 MOUNTING ACCESSORIES. BASIS OF DESIGN: KING LBP EUH-2 SHOP 134 1500 208 1 RECESSED WALL MOUNTED FAN POWERED ELECTRIC UNIT HEATER. CONTROLLED BY DDC OFF SPACE THERMOSTAT WITH CONTROL RELAY BY ELEC. HEAVY DUTY. BASIS OF DESIGN: KING LPWP EUH-3 EMS 132 1500 208 1 RECESSED WALL MOUNTED FAN 'POWERED ELECTRIC UNIT HEATER. CONTROLLED BY DDC OFF SPACE THERMOSTAT WITH CONTROL RELAY BY ELEC. HEAVY DUTY. BASIS OF DESIGN: KING LPWP EUH-4 MECH 133 1500 208 1 RECESSED WALL MOUNTED FAN POWERED ELECTRIC UNIT HEATER. CONTROLLED BY DDC OFF SPACE THERMOSTAT WITH CONTROL RELAY BY ELEC. HEAVY DUTY. BASIS OF DESIGN: KING LPWP EUH-5 MECHANICAL 2000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF - PLATFORM 202 CONTAINED THERMOSTAT, SET TO 65F. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING LBP EUH-6 STORAGE 201 1500 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT, SET TO 65F. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING LBP EUH-7 GEAR WASH 128 1500 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT, SET TO 68F. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING LBP REVIEWED FOR CODE COMPLIANCE APPROVED AVG 0 8 2019 City of Tukwila BUILDING DIVISION 3 414/19 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Correcctions#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENEUSCH GROUP, INC (ne) ws-om (RO0i 3]b06fI FM JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT' Date 7/25/2019' Sheet Title MECHANICAL SCHEDULES' Sheet M003 In IY W Z u In W 0 Z Q m ad U W H U K Q 0 _J ra n 00i R 1A GRILLES, REGISTERS AND DIFFUSERS SCHEDULE MARK CFM NC LEVEL STATIC PRESSURE CEILING OR MOUNT TYPE SIZE BASIS FOR DESIGN NOTES FRAME PANEL CONNECTION SD1 30 - 50 <20 0.01 GWB 12" X 12 6 X 6" TITUS MCD AA - 4 WAY THROW 1,2,3 SD2 60 - 110 <20 0.01 GWB 12 X 12" 6 X 6" TITUS MCD AA - 4 WAY THROW 1,2,3 SD3 150-200 <20 0.03 LAY -IN 24" X 24 8 X 8 TITUS MCD AA - 4 WAY THROW 1,2,3 SD4 200 <20 0.03 GWB 14" X 14 8 X 8 TITUS MCD AA - 4 WAY THROW 1,2,3 SD5 250 <20 0.02 GWB 16 X 16 10 'X10 TITUS MCD AA - 4 WAY THROW 1,2,3 SD6 300-400 <20 0.03 DUCT WALL 14 X 14 12 X 12 TITUS 300 IRS 1,2,3 SD7 400 1 <20 0.02 WALL 22 X 12 20 X 10 TITUS 300 IRS 1,2,3 SD8 4500 <20 0.04 GWB 38" X 38 36" X 36 TITUS 300 IRS 1,2,3,4 SD9 50-75 1 <20 0.03 LAY -IN 26" X 6 6 OVAL TITUS ML-39, 2 SLOT MP-39 PLENUM 1,2,3 SD10 150-170 <20 0.04 LAY -IN 50 X 6 10 OVAL TITUS ML-39, 2 SLOT MP-39 PLENUM 1,2,3 SD11 150-170 1 <20 0.04 LAY -IN 50 X 6 10 OVAL TITUS ML-39, 2 SLOT MP-39 PLENUM 1,2,3 SD12 200-250 QO 0.05 LAY -IN 50 X 6 12 OVAL TITUS ML-40, 2 SLOT MP-40 PLENUM 1,2,3 SD13 150-165 <20 0.03 NONE 18 DIA 8 DIA TITUS TMRA 1,2,3 SD14 250 <20 0.01 DUCT 20 X 10 18 X 8" TITUS 300 IRS 1,2,3 SD15 450 <20 0.03 LAY -IN 24 X 24 14 X 14" TITUS MCD AA - 4 WAY THROW 1,2,3 SD16 150 <20 0.05 LAY -IN 26 X 6 8 OVAL TITUS ML-39, 3 SLOT MP-39 PLENUM 1,2,3 RG1 50 - 240 <20 0.03 GWB 12 X12 10 X 10" TITUS 350ZFS 1,2,3 RG2 250 - 64q <20 0.03 18 x18 16" x 16" TITUS 350ZFS 1,2,3 RG3 1000 1 <20 0.03 DUCT 24 DIA. 22 DIA PRICE RECG 1,2,3,4 RG4 125-150 1 <20 0.03 LAY -IN 26 X 6 8 OVAL TITUS MLR-39, 3 SLOT MP-39 PLENUM 1,2,3 RG5 200 1 <20 0.05 LAY -IN 26 X 6 8 OVAL TITUS MLR-39, 3 SLOT MP-39 PLENUM 1,2,3 RG6 1000 1 <20 0.03 GWB 38 X 14' 36 X 12 11TUS 350ZFS 1,2,3,4 RG7 200 1 <20 0.025 LAY -IN 24 X 24 10 X 10 TITUS 350ZFS 1,2,3 EG1 30 - 80 <20 0.01 GWB 8" X 8" 6" X 6" TITUS 350ZFS 1,2,3 EG2 100-200 <20 0.02 DUCT GWB 12 X 12 10 X t0 TITUS 350ZFS 1,2,3 EG3 100-200 <20 0.02 WALL 14" X 10 12 X 8 TITUS 350ZFS 1,2,3 EG4 250-300 <20 0.02 DUCT GWB 14" X 12 12 X 10" TITUS 350ZFS 1,2,3 EG5 300 <20 0.034 WALL 18" X 10" 16" X 8" TITUS 350ZFS 1,2,3 EG6 800 <20 0.02 DUCT 26 X 16 24 X 14 TITUS 350ZFS 1,2,3 EG7 400 <20 0.02 WALL 20 X 12 18 X 16" TITUS 350ZFS 1,2,3 EG8 4500 <20 0.034 GWB 42 X 42 40 X 40" TITUS 350ZFS 1,2,3,4 EG9 50 - 75 <20 0.02 ACT 26" X 6" 6 OVAL TITUS MLR-39, 2 SLOT MP-39 PLENUM 1,2,3 TGt 100 - 300 <20 0.02 DOOR 22 X 16 20 X 14 TITUS T700S 1,2,3 TG2 100 - 30 <20 0.069 GWB 20 X 12 18 X 10" TITUS 350ZFS 1,2,3 TG3 150 <20 0.01 GWB 16" X 8 14" X 6 TITUS 350 RS 1,2,3 X 4 S: 1. DUCT CONNECTION TO DIFFUSER OR GRILLE SHALL BE MINIMUM NECK SIZE. 2. PROVIDE SMOOTH, GRADUAL SHEETMETAL FITTING TRANSITION FROM DUCT TO GRILLE, REGISTER OR DIFFUSER. 3. REFER TO ARCHITECTURAL PLANS (FLOOR, CEILING AND ELEVATIONS) TO DETERMINE FRAME TYPE AND LOCATION. 4. PROVIDE ADDITIONAL STRUCTURAL SUPPORT FOR OVERSIZE AIR TERMINAL AS REQUIRED. ROOF VENTILATORS PRESSURE THROAT WEIGHT, MARK CFM DROP DIMENSIONS LBS. REMARKS RV-1 400 0.05 12 X 12 50 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER RV-2 INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS OF DESIGN: GREENHECK FGI RV-3 4500 0.05 36 X 36 160 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGI RV-4 800-1000 0.05 20 X 20 80 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER RV-7 INTERLOCKED TO ASSOCIATED FAN OPERATION. RV-8 BASIS: GREENHECK FGI RV-5 800-1000 0.05 20 X 20 80 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER RV-6 INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGR VEHICLE EXHAUST EXTRACTION SYSTEM MARK REMARKS VEF VEHICLE EXHAUST FAN. SWBI, 2400 CFM, 8.0 TOTAL STATIC PRESSURE, 3450 RPM, 7.5 HP, 208V, 3 PHASE. PROVIDE WITH DISCONNECT, VFD AND SILENCER. BASIS OF DESIGN: GREENHECK OR ACCEPTED EQUAL. RAIL NEDERMAN MAGNA RAIL. PROVIDE TWO 6 DROPS, WITH ELECTROMAGNET RELEASE, EACH. 208 VOLT/1 PHASE. REFER TO CONTRACT DRAWINGS FOR REQUIRED LENGTHS AND ARRANGEMENT. DUCT ATTENUATOR SCHEDULE MARK ROOM DUCT TYPE LENGTH STATIC PRESSURE DUCT CONNECTION FACE VELOCITY OCTAVE BAND INSERTION LOSS BASIS FOR DESIGN 63 125 250 500 1000 2000 4000 8000 DA-1 MECH PORCH EXHAUST 60" 0.12" 18 X 12 +11500 FPM 4 8 14 17 19 15 13 10 VIBRO-ACOUSTICS RD-HV-F1-60 1 , 2 TOTE: 1) MAXIMUM STATIC PRESSURE LOSS AT INSTALLED SIZE (2) MAKE DUCT CONNECTIONS TO ATTENUATOR WITH GRADUAL TRANSITIONS AIR COMPRESSOR SCHEDULE MARK VOLTS CYCLES MOTOR MAX REMARKS PHASE I P PSIG ACFM COMP-1 208/60/3 5 175 14 80 GALLON VERTICAL TANK MOUNTED MOTOR AND COMPRESSOR. BELT DRIVE RECIPROCATING COMPRESSOR. PROVIDE INSTALLED WITH VIBRATION ISOLATION, FILTER MOISTURE TRAP AND PRESSURE REGULATOR. BASIS FOR DESIGN: INGERSOLL RAND 2475-N5 COMP-2 208/60/1 2 - - DRY RISER COMPRESSOR BY FIRE SPRINKLER. DESIGN BUILD CONTRACTOR. LOCATED IN MECHANICAL ROOM. BASIS FOR DESIGN: GAST LOUVER SCHEDULE APPLICATION FREE AREA FREE AREA AIR STATIC LOUVER BASIS MARK CFM SQ. FT. VELOCITY (FPM) PRESSURE SIZE IN. FOR DESIGN REMARKS L-1 8,000 1 EXHAUST 23.54 1 340 0.02 56x104 GREENHECK ESD 435 1,2,3,4 REMARKS: 1. PROVIDE WITH MOTOR OPERATED DAMPERS FOR EACH PARTITIONED SECTION. 2. PROVIDE WITH BIRD AND INSECT SCREEN. 3. LOUVER L-1 IS COMMON TO THE ENTIRE PORCH OPEN ELEVATION. CREATE A LOUVERED AREA DEDICATED TO THE VER BY C NNEC-n IG AN 56" X 30" EXHAUST TRAN [ON FITTING DIREC Y TO THE L UVER -1. 011 4 REVIEWED FOR CODE COMPLIANCE APPROVED Am 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 414119 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP. INC amuwcr. Nua wru a rm�arvacv. olmarm+o I000 am � a W mmc w carts JURISDICTIONAL APPROVALSTAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL SCHEDULES Sheet I IO04 In Ce w z u N w 0 z Q m Od In H u w H V �0 J >A rr° #A� r.3 soull A%J%-F v MECHANICAL SITE PLAN NORTH SCALE: 1/16" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila BUILDING DIVISION 3 414/19 Permit Revision 1B 12/11/18 Design Revisions 1A 12111/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC SIA JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL SITE PLAN Sheet n n 101 V) od W Z u Ln W 0 Z co m rY E- V w h V Eq W J ro r 2"W UP TO FD-1— J- — - — - — - — - 4"W UP TO STANDPIPE DRAIN 6"F UP 2"W UP TO ED-2- 4"W UP TO EQQ- 3"CW UP. � - — - — - — - — - 3"CW TO 2" METER, SEE CIVIL 9 C5.2 FOR CONTINUATION - SHEET NOTES: FLAG NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS SLEEVE ALL FOUNDATION WALL PIPE PENETRATIONS, TYPICAL. AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS RE IRED OR CODE OMP NT I TALL ON. REFER TO AND TO DETAIL 12 IN STRUCTURAL DRAWINGS. M90 S301 COORDINATE PENETRATIONS WITH FOUNDATION PLAN ON SHEET S201. 1 2.1 2 3 3.1 5 6 7 3"W UP TO AD-1 2"W UP TO 4"W UP TO WC_1 4"W UP TO ECQ 3"W UP TO - ' ------- - — — -- -- -- ---- ---- - — - — - — - — - — - --- — - — - — - — - - - — TO . P r 2"V UP 2"V P 4"UP 2"V UP, TYP 2 2"W P TO ECQ 4"W UP TO TO TD-1 4"W UP TO ECQ �q x To TOP1 2"W UP TO Ep_j / 1 4 MECHANICAL FOUNDATION PLAN SCALE: 1/8" = 1'-0" 6"RWL TO SITE STORM, I.E. = 29'-0", SEE CIVIL 9 C2.0 FOR CONTINUATION 2f PROVIDE HEAT TRACING OF DOMESTIC COLD WATER PIPE. SEE 2 3 5 M20 M201 S30 OFFSET PIPE WITH 90 DEGREE ELBOWS IN VERTICAL AND HORIZONTAL DIRECTION, TO ALLOW FOR PIPE MOVEMENT EVENT. APPLIES TO FIRE PROTECTION AND COLD WATER SUPPLY PIPING. _ _ _/' —�'a"CW UP GAS METER %—TO SITE GAS SERVICE, SEE CIVIL %N FOR CONTINUATION C4.0 —4"W UP TO QQQ 6"W TO OIL WATER SEPARATOR, I.E.=29'-0", SEE CIVIL 1 FOR CONTINUATION C4.0 �- - - - - - - - - - — _ 6�T0_ SANJ'[AB`�$E�YFI3,,.._I�=29'-0 "� -SEE-C 1 OR -CONTINUATION----------------------- /lam /lam / REVIEWED FOR CODE COMPLIANC APPROVED / AUG 08 2019 / City of Tukwila BUILDING DIVISIOP RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 414119 Permit Revision 12/11118 Design Revisions 12/11/18 Permit Corrections #1 r915 Southcenter Parkway ,. v ukwila, WA 98188 in GREENBUSCH GROUP, INC owt. s�D�.rmm °mixalls El �j J I n a ME I U� rn C 0 r. 01 2 aI g m ui M a v It rn 0 Co N FIRE SPRINKLER NOTES 1. THESE DRAWINGS ARE DIAGRAMMATIC REPRESENTING THE INTENT OF THE WORK. REFER TO THE SPECIFICATIONS FOR COMPLETE SYSTEM REQUIREMENTS. 2. PROVIDE ALL DESIGN, MATERIAL, LABOR, SUPERVISION, TOOLS, AND ITEMS NECESSARY, FOR THE CONSTRUCTION, INSTALLATION, CONNECTION, START—UP, TESTING AND OPERATION OF ALL FIRE SUPPRESSION WORK FOR THIS PROJECT. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO DESIGN AND INSTALL A COMPLETE WORKING SYSTEM MEETING ALL CODES. 3. THE INTENT OF THESE DRAWINGS IS TO DIAGRAMMATICALLY SHOW THE FIRE SPRINKLER PIPING AND ARRANGEMENT OF HEADS IN OCCUPIED AND CRITICAL AREAS ONLY. SPRINKLER HEADS PROTECTING ATTICS, CONCEALED AREAS AND PLENUMS ARE NOT INDICATED BUT REQUIRED.THE DRAWINGS DO NOT NECESSARILY REFLECT THE FULL EXTENT OF PIPE OR SYSTEM COMPONENTS REQUIRED OR EXPECTED. THE FIRE SPRINKLER CONTRACTOR IS NOT RELIEVED FROM INCLUDING ALL REQUIRED COMPONENTS AND WORK IN THEIR CONTRACT. 4. PROVIDE SPRINKLER HEADS, PIPING, HEADERS, VALVES, ALARMS AND ACCESSORIES AS REQUIRED FOR A COMPLETE, FUNCTIONAL, CODE COMPLIANT SYSTEM. PIPE SIZING SHOWN IS AN ESTIMATE, FINAL PIPE SIZE SHALL BE COMPLETED BY THE CONTRACTOR AND INCLUDED IN THE PERMIT SUBMITTAL, CONSTRUCTION SHALL NOT BEGIN UNTIL THE CONTRACTOR'S SHOP DRAWINGS ARE APPROVED BY THE LOCAL JURISDICTION AND SHOP DRAWINGS HAVE BEEN REVIEWED BY THE PROJECT ARCHITECT. 5. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE ADDITIONAL HEADS, PIPING, VALVES AND APPURTENANCES TO ENSURE ADEQUATE COVERAGE IN ALL SPACES INCLUDING ABOVE CEILINGS, IN CRAWLSPACES AND IN ATTICS. 6. THE AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 (IBC 903.31 STANDARDS), IBC, IFC AND ALL LOCAL CODES AS A MINIMUM STANDARD. ADDITIONAL REQUIREMENTS WILL BE NOTED IN THE SPECIFICATIONS OR IN THESE DRAWINGS THAT EXCEED CODE REQUIREMENTS. 7. PROVIDE COVERAGE FOR THE ENTIRE FACILITY INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC SPACES, CATWALKS, INTERSTITIAL SPACES, OVERHANGS AND MECHANICAL/ELECTRICAL ROOMS TO ACCOMPANY THE AHJ CODE REQUIREMENTS. THE ASSUMPTION OF FIRE ALARM DEVICES OR SYSTEMS BEING INSTALLED DOES NOT RELIEVE THE FIRE SPRINKLER CONTRACTOR OF PROVIDING COMPLETE COVERAGE OF ALL AREAS. 8. FIRE SPRINKLER MAIN NOT SHOWN SHALL BE LAID OUT PER CODE SPECIFIED AND SYSTEM REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR AREAS NOT SHOWN OR FOR MULTIPLE FLOORS THAT REQUIRE FIRE SPRINKLING COVERAGE. 9. ALL PIPING SHALL BE CONCEALED IN FINISHED AREAS TO THE GREATEST EXTENT POSSIBLE. ANY EXPOSED PIPING IN UNFINISHED AREAS SHALL BE ONLY BY APPROVAL OF THE ARCHITECT AND BE PAINTED TO MATCH SURROUNDINGS. IN VAULTED CEILING AREAS, PIPING SHALL BE INSTALLED IN SOFFIT OR BEHIND CEILING FINISH. 10. SEE ARCHITECTURAL DRAWINGS FOR ATTIC AND CONCEALED SPACES, PROVIDE SPRINKLER COVERAGE IN THOSE SPACES AS APPLICABLE. IT. PROVIDE PREACTION FIRE SPRINKLER COVERAGE IN COMM ROOM. 12. EXPOSED FIRE SPRINKLER PIPING SHALL BE LIMITED TO THE AREAS SHOWN. ANY DEVIATIONS IN THE FIRE MAIN LAYOUT SHOWN HERE SHALL BE APPROVED BY THE ARCHITECT BEFORE INSTALLATION AND SHALL BE AT NO ADDITIONAL COST TO THE OWNER. NO EXPOSED PIPING WILL BE ALLOWED IF, IN THE BUILDING STRUCTURE, THE ARCHITECT HAS PROVIDED SHAFTS, FURRED AREAS OR CONCEALED SPACES WHERE PIPING COULD BE HIDDEN FROM VIEW. DO NOT RUN PIPING OVER ELECTRICAL PANELS OR SWITCHGEAR EXCEPT WHERE LOCATED ABOVE THE STRUCTURAL CEILING, 13. CENTER SPRINKLER HEADS AND OTHER EXPOSED SPRINKLER SYSTEM ACCESSORIES IN CEILING GRIDS ON CENTERLINES OF ARCHITECTURAL FEATURES. REFER TO ARCHITECTURAL. 14. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF THE PIPING AND HEADS TO AVOID INTERFERENCE WITH LIGHT FIXTURES, ELECTRICAL CABLE TRAYS, HEATING/COOLING EQUIPMENT, DUCTWORK AND ANY ARCHITECTURAL FEATURES SUCH AS SKYLIGHTS, STAIRWAYS, ETC. IN CATWALK AREAS, PIPING SHOULD BE RUN AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM HEADROOM OVER THE MECHANICAL EQUIPMENT AND AISLE SPACES. MAXIMUM CLEARANCE SHALL BE MAINTAINED FOR SERVICE ACCESS AND MAINTENANCE FOR ALL EQUIPMENT. FAILURE TO COORDINATE SHALL BE JUSTIFICATION TO REQUIRE THE CONTRACTOR, AT HIS OWN EXPENSE, TO MOVE AND REDO HIS WORK. 15. ALL PIPING SHALL BE SLOPED PARALLEL TO BUILDING STRUCTURE AND INSTALLED TO DRAIN. 16. PROVIDE THRUST BLOCKS AT ALL CHANGES IN DIRECTION FOR UNDERGROUND SERVICE PIPING. 17. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE, RECESSED HEADS WHERE EXPOSED IN CEILINGS. 18. PROVIDE DRY PIPE FIRE SPRINKLER COVERAGE FOR ALL EAVES AND OVERHANGS THAT EXTEND BEYOND 4' FROM THE BUILDING, COVERED WALKWAYS/ENTRYWAYS AND ANY UNCONDITIONED AREAS AND SPACES. 19. PROVIDE HEAD GUARDS OR WIRE PROTECTIVE CAGES AS REQUIRED ON ALL SPRINKLER HEADS THAT MAY BE SUBJECT TO DAMAGE BY INCIDENTAL CONTACT. ® WET UPRIGHT SPRINKLER HEAD OWET PENDANT SPRINKLER HEAD WET UPRIGHT ABOVE PENDANT DRY UPRIGHT SPRINKLER HEAD OHIGH TEMPERATURE SPRINKLER HEAD FIRE PROTECTION WATER F DRY SIDEWALL SPRINKLER HEAD M 0 BUILDINGf�� s �Il�ill�l�-lil �'f=.lt0`i fSr�l►6 : =:-1�IIr 1 1 Z ° o° (D a DO NOT BLOCK ACCESS CHECK VALVE PERIMETERS OF MINIMUM CLEARANCES TO BE PAINTED ON FLOOR IN WHITE ENAMEL PAINT STRIPE, WITH 2 INCH STENCILED BLACK TO BUILDING FIRE LETTERS TO SAY: "DO NOT BLOCK ACCESS" SPRINKLER SYSTEM z z 0 M m DOUBLE DETECTOR CHECK VALVE SCHEMATIC SCALE: NONE DETAIL NOTES: �� 1. RISER DIAGRAM IS DIAGRAMMATIC AND DOES NOT RELIEVE ALARM GONG OR WAIVE ANY IFC, NFPA, OR LOCAL REQUIREMENTS F DRAIN TO WALL EXTERIOR OR MOUNTED STANDPIPE, TYP PIV —. WET PIPE VALVE FLOW SWITCH, T FDc T DOUBLE DETECTOR CHECK BACKFLOW ASSEMBLY — FIRE SUPPLY MAIN —� F FIRE SPRINKLER RISER DIAGRAM SCALE: NONE ATTACHMENT t i 1 I 1 — _ (I I i t 1 rY ' \ 1 I 1 11 -_ 1 !/' ECR S. 7 ST elf Isms M .� ,et 5 U� Water ,Availability Site Map Legend -- TukwilaFire Station No.51 Hydrants M Water meters C) Parcel3523049008 N Valves a(+8 365 Zone Water Main 000 Q 18" LONG SPOOL (FL x PE) FLANGE COUPUNG ADAPTOR (D APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA © O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L & 1 © METERED 3/4 INCH BY—PASS DCVA — BY—PASS METER SHALL BE A 3/4 INCH SENSUS—ECR" SR POSITIVE DISPLACEMENT METER. © WALL MOUNTED FIRE DEPARTMENT CONNECTION. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY—PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SUBMITTED TO LOCAL AUTHORITYS WATER LIPUTY ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW UNE. INSTALL BRASS PLUGS AT ALL TEST COCKS. WET PIPE SYSTEM (TYP) DRY PIPE SYSTEM (TYP) TO FIRE ALARM PANEL, TYP TO COMPRESSOR RELEASE PANEL PREACTION VALVE I-�I DRY PIPE VALVE TEST DRAIN, TYP AIR COMPRESSOR, PROVIDE WITH 4" HOUSEKEEPING PAD DETAIL NOTES: DDCVA MUST BE INSTALLED IMMEDIATELY AFTER PIPE PENETRATION THROUGH BUILDING FLOOR SLAB. ROOM IN WHICH DDCVA IS LOCATED SHALL: A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. B. HAVE A HEATING SYSTEM (40- F MIN. TEMP.) NO HEAT TAPE C. NOT BE USED FOR STORAGE AROUND THE DDCVA D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIV. A RIGHT —OF —ENTRY AGREEMENT MUST BE GRANTED TO THE LOCAL AUTHORITY FOR INSPECTION OF THE DDCVA AND METER. SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA MUST BE SUBMITTED TO THE LOCAL AUTHORITY FIRE PREVENTION DEPARTMENT FOR REVIEW AND APPROVAL. A SEPARATE FIRE SPRINKLER PERMIT IS REQUIRED. 24 INCH MINIMUM 36 INCH MAXIMUM d i FINISH FLOOR LEVEL ELEVATION VIEW OF DDCVA 1. CONTRACTOR TO PROVIDE DESIGN, ENGINEERING AND DOCUMENTATION REQUIRED FOR ALL SYSTEM BRACING, HANGERS AND SUPPORTS. SIZE ALL RODS AND BRACE PIPES PER NFPA AND AUTHORITY HAVING JURISDICTION. RETAINER STRAP STEEL STRUCI CONCRETE DECK DROP —IN ANCHOR ALL THREAD ROD —HANGER RING DROP —IN HANGER NUT WALL/COLUMN PERIMETER BEAM BEAM CLAMP EXPANSION BOLT SWAY BRACE END BRACE PIPE ALL THREAD ROD P1 HANGER RING �-- FAST CLAMP TOP BEAM CLAMP LATERAL SWAY BRACE CONCRETE CONNECTION CONCRETE/STEEL SPRINKLER HANGER DETAIL WALL/COLUMN PERIMETER BEAM - EXPANSION BOLT - SWAY BRACE END BRACE PIPE — SCALE: NONE �— SWAY BRACE END IU— PIPE CLAMP LONGITUDINAL SWAY BRACE FIRE FLOW INFORMATION — TEST REPORT PROVIDED BY HIGHLINE WATER DISTRICT STATIC DEMAND GPM STATIC PRESSURE PSI STATIC HEAD FT. FIRE FLOW DEMAND GPM RESIDUAL PRESSURE PSI AVAILABLE FLOW AT HYDRANT GPM AVAILABLE FLOW PRESSURE PSI 4.46 150.01 363.99 2500.00 122.18 6025.78 20.00 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 8 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 414119 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11118 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC tOgD5mno mm a xaurr+i. M.M, 91AFLI fmE t0i B376- M flAX (10E) 371-066Y (20!) J7B-004/ FAX JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title FIRE PROTECTION' ABBREVS., LEGEND,, NOTES, & INDEX Sheet M301'I Ln W W z V In LU z Q m ex �L T F�— V W h- v Q 2.1 3.1 5 (6) ------------------ ------------------- ------- 0 3 i ------------- - --- O O ------------------- F- ---- ------------------- _ - - - —- - --- - -- - --- - - - - - - ------------_-- ----- _--______ = - ------ -- ----- ----- --- -- ---- ------------ --- E I STOR RE&EIi BUNK BUNK ® 198 , 0 COMM 122 11271 DECON 121 120 _____ _________ i q� �� K 1 1 1 1 I i 12C 126 1 \\JJ "�i -� ® OQ ® CORRIDOR L---------------- J L---------- J AIRLOCK CORRIDOR 123 135 ® ® i D CLEAN -----------------� ----------------- --PUTUI A ASH BUNK Derox, LAUNlJA 118 118 1------- 128 ®®17 I ® ll—��-- i SCBA 137 FFF 0 qI� i I � i 116 BI�IK BATH �I 115 I APP BAY GEAR STOR j® 130 129 I SHOP® ® ®Ir CORR —__ 134 ADA BAT '„ 110®i 114 B K � 14 ®i 112 CAP BUNK --- EMS D B H j172 C ------ - 13 - ------------- -- ---- 1 1 � I UP O R AIRLOCK , ORRIDOR SPRINKLER RISER 131 1 9 SEE M30 ADA @02 � MAINTAIN 4 FT.� CLEARANCE INDIC ENTRY VESTIB L BY HATCHED ARE 0 �1 101 B"F �\ ® STATION OFFICE '. 3 �+- ® CAP O =FICF® B to ® \ 10 6 F ON q------ - - -- ------------------- ----- - - -- -- -� . .....- PIV _.— FDC------------------ M LEVEL 1 FIRE PROTECTION DIAGRAM o-- �- — - — - — - SCALE: 1/8" = 1'-0" �� MECHANICAL PLATFORM AND LOWER ROOF FIRE PROTECTION DIAGRAM SCALE: 1/8" = 1'-0" O COURTYARD (OPEN TO ABOVE) PHYS TRAIN 106 0 i------- -- --- - - -- GA ME R ® ALO VE ELEC DAYROOM 105 ® 104 B ® B I � E ------- C1 ------- B1 FLAG NOTES: PROVIDE SPRINKLERS ABOVE AND UNDER ROLL UP DOORS,AS REQUIRED, TYPICAL. DRY PENDANT SIDEWALL SIDE WALL HEADS OR DRY SYSTEM, AS REQUIRED FOR COVERAGE, TYPICAL. PROVIDE WITH PRE -ACTION SPRINKLER �3 SYSTEM. REVIEWED FOR CODE COMPLIANCE APPROVED "AUG 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019. PERMIT CENTER 3 4/4/19 Permit Revision 1B 12111/18 Design Revisions 1A 12t11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENHUSCH GROUP, INC Mii am 318-WI FAX JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title FIRE PROTECTION FLOOR PLAN Sheet M302 In 04 UJ z V In W 0 z Q CG ad 0 -t- In ry v u ."i 1w I n Ne DRAWING NOTES: FLAG NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND FOR COMPRESSED AIR RISER DIAGRAM, SEE 2 2 POSITION GAS SOLENOID VALVE. SHUT OFF GAS TO OFFSETS AS REQUIRED TO AVOID WORK OF 80 ✓ APPLIANCE WHEN STATION CALL ALARM IS ACTIVATED. OTHER TRADES AND AS REQUIRED FOR A CODE MANUAL RESET. COORDINATE LOCATION WITH ARCHITECT. COMPLIANT INSTALLATION. PROVIDE TRAP PRIMER CONNECTION FOR ALL FLOOR DRAINS. CONTRACTOR SHALL LOCATE MANIFOLD AND 7 GAS RESET BUTTON FOR KITCHEN APPLIANCES. LOCATE ON PROVIDE ACCESS PANEL IN COORDINATION WITH THE END OF THE KITCtIEN ISLAND. ARCHITECT, PROVIDE CLEANOUT AT BASE OF RAINWATER AND SANITARY SEE 90 8� PLUMBIN LEADERS M90 TYP ALRAINWATER AND SANITARY STACKS 1A 3� FOR GAS RISER DIAGRAM, SEE 1/1'1 r� 80 9' > FOR COMPLETE DOMESTIC WATER PIPE SIZES, v FOR DISHWASHER CONNECTION, SEE SEE DOMESTIC WATER PLUMBING RISER DIAGRAMQ 4� _ . 7 90 B� 10 EXTEND RH-1 ROOF HYDRANT DRAIN PORT PIPING TO BW-1 5 PROVIDE CONDENSATE DRAINAGE PIPING AS SHONN. DRAIN DRAIN SUMP. TO NEAREST SUITABLE FLOOR OI2WN OR PLUMBING FIXTURE TAIL PIECE REFER TO DETAIL 90 11 NO SANITARY CONNECTION REQUIRED AT THIS WALL BOX LOCATION. COLD WATER AND HOT WATER SUPPLY ONLY. PARTS WASHER DRAIN SHALL BE DIRECTED TO SINK Ems, 3 3.1 4 5 g 7 3 3 o II II RECEIVED CITY OF TUKWILA LEVEL 1 PLUMBING PLAN AUG 01 2019 SCALE: 1 j8" = 1'-0" 4)NORTH M�qa, Mq PERMIT CENTER 3 4t4119 Permit Revision 1B 12/11/18 Design Revisions 1A 12111/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG tE GREENBUSCH GROUP. INC �casnai.� �mrn a rFawac¢ e+axaran raoo wsr car �re m� mmr. ra cent (206) 3�G-06eD (106) 77e-0e41 fA% JURISDICTIONAL APPROVAL STAMP ' Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title LEVEL 1 PLUMBING PLAN Sheet M401 LA 04 LU V LA w 0 Z Q m F V w F V K Q FRI n Ve 1 I t 1 I I I I I GAS UNIT HEATER, SEE 903 TYP 1 c gl 1 M LL C RE ---- U _ — 0 ZJ UnL Ur IU ( - 00 M m 3"RWL UP TO M 6 "u= a v rn 0 rn N 3"ORL UP TO M - 3"RWL UP TO 9M 1A T'4 HWC,2"HW, 2WCW, 1Y4"CA ON � - — - — - — - — - — - COMP_1 AIR COMPRESSOR, SEE(@TYP� 903 I I I 1 SCALE: 1/8" = 1'-0" 2.1 2 \� I I II II II II II I II I II II JI 2.1 2 2"V DN, TYP 2 3 3.1 II II I II 1 II II II II 5 I I I I I I I I I I SHEET NOTES: FLAG NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND _ I 1 j PROVIDE TRAP PRIMER CONNECTION FOR ALL FLOOR OFFSETS AS REQUIRED TO AVOID WORK OF OTHER DRAINS. CONTRACTOR SHALL LOCATE MANIFOLD AND TRADES AND AS REQUIRED FOR A CODE COMPLIANT PROVIDE ACCESS PANEL IN COORDINATION WITH INSTALLATION. ARCHITECT, SEE 90 W FOR GAS RISER DIAGRAM, SEE Q r3> �` FOR COMPLETE DOMESTIC WATER PIPE SIZES, tt SEE DOMESTIC WATER PLUMBING RISER DIAGRAM 80 FOR COMPRESSED AIR RISER DIAGRAM, 6 7 8 I � I I i I I I I I I i I i I I I I I , I , 1 II I — - — - — - - — - - - i - - — - — - — -� - - - — - — - — - - ------------- - — -—-------- I t I I II i i I i II i I I i I I I 1 i i 3 3.1 4 5 6 7 4) NORTH - — - — - — - — - — - — - — - — - - — - - — - — - — - — - — - — - — - — --- C ----------------------------- B1 SCALE: NONE IN SUPPLY VALVE UM BREAKER EVIEWED FOR C DE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila B LDING DIVISION RECEIVED Y OF TUKWILA AUG 01 2019 RMIT CENTER 3 414/19 Permit Revision 1B 12111/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC rzouslrJu. uao 0 a wiawani. ormsnam �mo wear xa¢ns�axax acre mr sFwmc za) s�e-� (snel sre-oa+i Fvc JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/2512019' Sheet Title MECHPLATFORM'i AND LOWER ROOF PLUMBING PLAN Sheet n A ^ O2 LA 04 UJ 0 N LU Z Q m a� -F tA V w N S V Q W F r4 Li n, SHEET NOTES: FLAG NOTES: 1. DUCT WORK IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER FLEXIBLE EXHAUST DUCT DROP FROM TRACK TO VEHICLE TRADES AND AS REQUIRED FOR A CODE COMPLIANT CONNECTOR. INSTALLATION. R::% PROVIDE DOOR SWITCH ON APP BAY ROLL —UP DOOR TO SHUT OFF HEAT WHEN DOOR IS OPEN, TYPICAL. L PROVIDE DOOR SWITCH ON PHYSICAL TRAINING DOORS TO TURN OFF HVAC WHEN DOORS ARE OPEN. CEILING FANS TO REMAIN FUNCTIONAL. 4�COORDINATE ID.0 INSTALLATION HEIGHT WITH ARCHITECT, TYPICAL ALL UNITS. INSTALL CO AND NOX SENSORS 5 FT. AFF. 1 2.1 3 3.1 4 5 6 T \\ LEVEL 1 HVAC PLAN SCALE: 1/8" = 1'-0" NORTH RECEIVED CITY OF TUKWILA AUG I 12019 PERMIT CENTER 3 4/4f19 Permit Revision 18 12111/18 Design Revisions 1A 12J11118 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG GROUP.THE GREENBUSCH , MEMN 37$-041 FM JURISDICTIONAL APPROVALSTAUIP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title LEVEL 1 HVAC PLAN Sheet M 501 Ln od w Z V Ln w 0 Z a Co �1 T 1.i W Z V 2 p SHEET NOTES: 1. DUCT WORK IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. F- — - — - — -- E---------- FOR LARGE SCALE PLAN, 11 6"COMBUSTION AIR -INTAKE, -5"--FLUE-VENT.- - CONNECT TO CONCENTRIC VENT, TERMINATE ON ROOF, TYP, 8 SEE gO3 12/12 UP TO RV-1 10/10 ON C -4£0MBUST ION-MR-INTAN 4" FLUE VENT, CONNECT CONCENTRIC VENT, TERMINATE ON ROOF SEE 2 901 12/12 UP TO RV-2 — SCALE: 1/8" = 1'-0" 1 2.1 2 PORCHMECH I �I 1 �M mm' M� R mom' W, it fl GAS UNIT HEATER, SEE �TYP 903 1' UH-2 3 3.1 4 5 6 7 ---------------i - - - -------------- - - - — - ----- - — - — - - - F ---------------------'------ ------ ----------- ---- Tb"RS, Y4"R DN QQIZ OUTDOOR (T, SEE r3oy \ LAUUNDRYVEN�TS, //////i 4 MAGNA-RAIL, M TYP 2 /26 TO TO 6 UP UP �- EF 6 �� � � / � ! ROOF VENTILATOR, 5 SEE TYP 4500 4500 _ D to it " ON TO -'RL RV-5 e�LZ i r..../ i OUTDOOR UNIT, E - EFL RV-8 to MOD 0' to M _$ UH_1_ 1 A _ __ _- _ -- --- -- -- ----------- -- ------ ;COMBUSTION AIR ---- -- --- 'I' ------ -- --�--- --- - � INTAKE, 5" FLUE VENT, CONNECT TO CONCENTRIC 1 VENT, TERMINATE ON 2 80 ROOF, TYP, 80 SEE 903 1 2.1 2 34 4 5 6 --------- B1 FLAG NOTES: FLEXIBLE EXHAUST DUCT DROP FROM TRACK TO VEHICLE CONNECTOR, TWO EACH TRACK. REVIEWED FOR CODE COMPLIANCE APPROVED "AUG 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 414/19 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENEUSCH GROUP, INC /COIafIGt. M "IM • Y®pWaGV. a (2.8)oe� JURISDICTIONAL APPROVALSTAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECH PLATFORM AND LOWER ROOF HVAC PLAN Sheet M502 i r , J I!niil n'� 1; SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. LEVEL 1 PIPING PLAN SCALE: 1/8" = 1'-0" RECEIVED CF Y Or T LIKWILA NORTH0 (mqN11T GENTER 3 415/19 Addendum 9 18 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENEUSCH GROUP. INC ,Mwustcu. xido Wei a urexwov. vart�mo tOw Misr SI W WM 201 SFATRL 0 Wilt(20e) ma-oeav (2oM) ale-Wi vex Issue REVISED BID SET Date 1/17/2019 Sheet Title LEVEL 1 PIPING PLAN Sheet M601 1 SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. 2 3 3.1 4 5 6 7 II II II II II II II @)------ ------ ( (; )---------------- B / ( d —----_---_-- I I I I I II II I II I 1 42 3 3.1 4 5 6 7 0 4 SCALE: 1/8" = 1'-0" ----------- SE ------------ ----------- 9 ----------- 91 -------------- ----------� REVIEWED FOR CODE COMPLIANCE APPROVED ` AUG 08 2019 City of Tukwila BUILDING DIVISION CITY OF TLIKWILA PERMIT CENTER 3 415119 Addendum 9 18 12/11118 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENe USCH GROUP, INC AGgffi'IMM. MpD YIpEO M 161Wl.902M.. (=$)�3 E-Mg (M) M-0841FNt Issue REVISED BID SET Date 1/17/2019 Sheet Title MECH PLATFORM AND LOWER ROOF PIPING PLAN Sheet n 602 N Cd LU V N w n Z on on Ce F- V w H V Ce El ro SHEET NOTES: 1. DUCT WORK AND PIPING ARE DAGRAMMATIC. PROVIDE FITTING AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. � - — - — - — - — - — - A UPPER ROOF MECHANICAL PLAN SCALE: 1/8" = 1'-0" 4 I I I I I I I i 5 I I I I 6 T 8 I � I I , I I , I ----------------- 4. - OH ---------------- I- O II II I —--------------------------------------------------------,- F ---—--—-—-—---—-—-—--T----------------------------------- E I I I ------------------------------------- C ---------------------------------- B1 3 4/4/19 Permit Revision 1B 12/11/18 Design Revisions 1A 12111/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENEUSCH GROUP. INC imumw. 7n10 raao a fEawasv. owa mis fi0C 1R4f 91PFET ARR >yl 53711E a1 — (20E) 3]6-PON (2UE) 3T1-06it FAY............ ---- — - --_�—----- �---------------------- -- OVAL � REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 8 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWI AUG I 12019 PERMIT CENTEI II� JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL ROOF PLAN Sheet n n % 0 1 1 f� rE /I E ( ) ------ - ------ -- ENLARGED MECHANICAL ROOM PLAN SCALE: 1/2" = 1'-0" SHEET NOTES: 1. DUCT WORK AND PIPING ARE DIAGRAMMATIC. PROVIDE FITTING AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. n V '0 " { "max x REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 414/19 Permit Revision IS 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC }ffffff f�f � 378�t FM JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL LARGE SCALE PLANS Sheet M Q O 1 V) W w Z U In W Q Z Q m Cd Z) In U w H U K 21 �J n L JL UH_2 200 MBH rr I I J L 0 N (500) o c� M ^ 1"G r *TO LPRV. VENT FULL SIZE MECH PLATFO M EXTERIOR, TYP DHWH 12821 150 MBH 150 MBH FIRST FLOOR GAS RISER DIAGRAM SCALE: NONE UPPER ROOF UH-1 1A 200 MBH (700) —1 Y4"G o (750) 1 (850) —Y4"G �—'— TWO —POSITION MANUAL RESET SOLENOID VALVE. CLOSE ON ALARM CALL -Y4"G r r I � I RANGE L 100 MBH L 50 MBH MEDIUM PRESSURE 2 LB. /GAS \METER, SEE I=a— LOWER ROOF FIRST FLOOR TO SITE GAS SERVICE CONNECTION NATURAL GAS FIRED APPLIANCE CAPACITY SCHEDULE INPUT CAPACITY MARK ITEM BTU/HR. CF HR REMARKS DHWH —1 WATER HEATER 150,000 146 24 7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR DHWH-2 WATER HEATER 150,000 146 24 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR UH-1 APP BAY UNIT HEATER 200,000 195 24 7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR UH-2 APP BAY UNIT HEATER 200,000 195 24 7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR RANGE KITCHEN RANGE 50,000 49 PROVIDE 2 PSI TO 6-14" REGULATOR BAR B QUE OUTDOOR BAR B QUE 100,000 97 PROVIDE 2 PSI TO 6-14" REGULATOR SUBTOTAL 850,000 828 FACTOR OF SAFETY 25% 212,5001 207 SUM 1 1,062,5001 1,035 PARTS WASHER 10 ACFM 10 ACFM 10 ACFM 10 ACFM 10 ACFM 10 ACFM 10 ACFM COMPRESSED AIR RISER DIAGRAM SCALE: NONE APP BAY RISER DIAGRAM NOTE: MAKE ALL CONNECTIONS TO THE COMPRESSED AIR MAIN FROM THE TOP, SEE 90 REVIEWED FOR CODE COMPLIANCE APPROVED ` AUG 08 2019 City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 414119 Permit Revision 1B 12/11/18 Design Revisions 1A 12JI1118 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC t NO3f60i1� ffiSI. 40i "M ( ) 37M.60 (a) 3711 0 1 Pvt JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL DIAGRAMS Sheet M Q O2 N W W z V In W 0 z Ce m a H V W I— V rl J 0 z>�^cw»�o _ _ _ -- _ _ -------------zHWHW 5v --- --- - I _ 2^CW �N I 3QD I IIN _ ' I �j_I{tj j II60 �Fl III j ;I IF 2^CW 43t5 wu 2^CW42o WU 2^ON xo WU � _ Cyy - _ _ _ _ _ _ _ _ lwcw ! FMt! - - - - _ _ _ 1NiCW 6.Q- ------------ T 1 �_� ___ __-__-I-__V-_---_ -------------- '-__VQ"-_-- f7 'jl 'I,I 'll III III III I 1 lil �i1 iil I 2WU 5 D@r1ESTIC WATER I 5<E 4 r I wu You 3wu 4.0 You Val) 1 YON FROM SITE, SEE OWL UFILITES RAN - DOMESTIC WATER PLUMBING RISER SCALE: NONE Indoor Units: 1212 to 50 Capacity 2041120 to 360 (85.0%) -Connectable capacity is not a=W <ap.dr }y. Total Pipe Length: 737A 12624.7 feet Furthest Actual: 119.0 / 541.0 feet FurthestEquw.: 1J87/623.0 feet After lst Branch Actual: 9601197,0 feet After 1st Branch Equiv.: 104,2119710 feet Connection Factors Outdoor Unit Capacity: 1.00 1.00 Temperature: 1.00 1.00 Piping Length: 1A0 0.99 Defrosting: - 1,00 User Derate: 1.00 1.00 Total Derate: 1.00 0.99 Additional Refrigerant: 47.9 Its Total Refrigerant Amount 94.2 lb Conditions (T Cooling Indoor D6 80.0 Humidity 518% Indoor W8 67.0 Outdoor DB 95.0 Heating Indoor DS 70.0 Outdoor OB 47.0 Humidity 728% Outdoor WB 43.0 REFRIGERANT DIAGRAM SCALE: NONE 3; DW25 WU 1 �' bl 2Ye^CW 71.0 WgU- - _ 2�i CW630 HSIU_ - 2"CVi550 wit} 41.5 W9U _ 2^CW 36.5 YOU _ 2"ON 3Q5 W�_U �4,0' ' t $ 11 CW &0 N�UU_ 1 "CiN WaFtl I , 2' HW - - 7 0 T. 2 tiVJ tns �_2_FhV y�1 0 W31} HW�2it0 t L _ 1z HW15 NSFU _ I r•- � -- --_ �I II-rt --- -- _ y t I I I 1 I 1 I 1 I _ --•4-t � I ,r CWa5Wes,, ''t T7•'y��- _- t ' d; S,''.- I Oil , I'll it ' 133�iI I , 1 I, I�1 � �1 11�11 1 1 1 I I , Ol of ,OI , N 1010 IcO.ItNI �I u!I I�'O ININI uil (0'O ,O'OI OI of O O' I too) OIO ,OI O) 10`OIrr31 Ol o) �t}( I 'OIO IOI OI OI I IO O rl) O u3 t tQl INN, o$f V �d') V' I3E IMS 3M oaf M3I t.- .33: t.: +�' N L_ N� ( �NI3N3I 1� .: rrf 33 NI dl j L:I C+�SI d) C33il 3d3l NI 1.-, N N a'1 �I°� �� I�I� I�III�I �,la, �. t�Ix�l a,IR� a 1�1<�1 �.f�, S �I a..`L"•I � �I� `�I� �'� °�I� � I�f� a; I '�la• �I� a. a. ? I (R� � � � � a. I� t � a"• a. I I 1 1 1 I I I 1 I 1 I I 'll',I II ;11'llll ;Illtll ;11',II ,'ll"tl',Itll'lII;11111 II',II I I I II I I I I I tll ;jl It�,� 'I ail i � � � I=Z � � � 1=2 � � � %--1 � �1 � � S-2. t=z � � � u �1. � 1�3 t=2. �1. M=i S-} � � � 25 1.0 1.0 No 1.0 20 4.0 50 1.0 20 5,0 1.0 20 50 ao ao 1.0 1.0 25 1.0 25 20 1.0 50 25 25 SO 1.0 25 1.5 1.0 ( 25 25 ' W9U vau you Vat) Wit} W911 wu VITU You V19U W}u vau YM WSFU 4,0 4� WU WU MM you NC-FU W3FU VOU � WSF11 MffU VfU WU W3U VOU WS U 0,55 Q� aQ5 aS VIM M W�U , wu Wfu VOU PURY-P240TSLMU-A Model Number Pipe Dia. Liquid 1 Gas " Total (Sens.) 3 g 240,600 BTU1h 266.519 BTU1h Cr Pipe Length (Elbows) Htg.Total Group/Room/Tag Ref. I1-1l8 1 1-318 CME-P1013NU GA -- -- _ _ 204,570 BTU/h (159.431 BTU/h] r_ VRI= - ODU 20-Oft ( 6 } 3/4 1- - 3.0ft , 1 ) 227.834 BTU1h 314 i 1-118 -2.0ft { 1) LPKFY-POBNHMU-E2 114 1 112 8.020 BTU1h (6.819 BTU1h) Est. Cooling Discharge Air Temp: 64.4 71.011(5) 8,993 BTUfh Est. Heating Discharge Air Temp: 902 i n ? lou•z 1/4 1 1/2 PKFY-P08NHMU-E2 8.020 BTU/h (6,819 BTU/h) Est Cooling Discharge Air Temp: 64A 70.Oft(5) 8,993BTUPrh Est. Heating Discharge AirTemp:902 z 121 lou-3 L114 1 112 PKFY-POSNHMU-E2 9.020BTU/h(6.819BTU1h) Est Cooling Discharge Air Temp:64.4 51.Oft (4) 8.993BTUIh Est. Heating Discharge Air Temp:902 3131 IDU-4 114 1 1/2 PKFY-PD8NHMU-E2 8.020 BTU/h (6.819 BTU/h) Est Cooling Discharge Air Temp: 64.4 43.011(4) 8.993BTUlh Est. Heating Discharge Air Temp:90.2 4141 IDU-5 114 1 1/2 PKFY-POBNHMU-E2 8,020 BTU1h (6,819 BTU/h) Est. Cooling Discharge Air Temp: 54A 35.OR(4) 8.9936TU/h Est. Heating Discharge Air Temp:902 5151 IDU-6 114 1 112 PKFY-POSNHMU-E2 8.020 BTU/h (6.819 BTU1h) Est. Coaling Discharge Air Temp: 54A 33.OR(5) 3.993BTU/h Est. Heating Discharge Air Temp:902 6161lou-7 1141112 P,L,F.Y.-yP7.2NCMU-ER4 12,030 BTU/h (8,605 BTUfhj Est Cooling Discharge Air Tamp: 592 55O(4) 13.490 BTU/h Est Heating Discharge Air Temp: 102.1 7171 IDU-8 1/4 / 112 PLFY-P72NCMU-ER4 G^ 12.030 BTU/h (8.605 BTU1h (. j Est Cooling Discharge Air Tem 592 p 20.0ft ( 3 } 13,490 BTU/h Est. Heating Discharge Air Temp:102.1 sisrlou-s 3181518 PEFY-P36NMAU-E 36.090 BTU/h (27.356 BTUth) Est. Gaoling Discharge, Air Temp: 57.8 11.Oft (4) 39,971 BTU/h Est. Heating Discharge Air Temp: 101.8 9 is I IOU-10 318 1 5f8 PEFY-P24NMAU-E2 ��- 24.060 BTU/h (19.237 BTUth) Est Cooling Discharge Air Temp: 59.4 41.OR (4) 26.98D BTU/h Est. Heating Discharge Air Temp: 98.3 1011011DU91 318 t 518 PEFY-P35NMAU-E 1 - 36.090 BTU/h (27.356 BTUIh) Est. Coaling Discharge Air Temp: 57.8 88.0R ( 5) 39.971 BTU/h Est. Heating Discharge Air Temp: 101.8 11 Ill 11DU-12 3161518 PEFY-P36NMAU-E 411-1 36.090 BTU/h 27.356 BTUlh ( } Est Coaling Discharge Tem 57.8 9 r9 P 96.Oft (5) 1211211DU-13 39.971 BTU/h Est. Heating Discharge Air Temp: 1 01a WA91M-DMCTM SEE I I I I L------4'iCW25V5FU ----) 00 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila BUILDING DIVISION i;ECEIVED CITYCF TLIKWiLA 'i 1'sJ PEPEAT CENTER 3 415/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENEUSCH GROUP, INC ta�. auwo � sew ��xr Pis Mile A) 3/a-0041 fNf Issue REVISED BID SET Date 1/17/2019 Sheet Title MECHANICAL DIAGRAMS Sheet M803 to w to Z _U to uu 0 Z Q m W -h to H V S ce LY i r` n ail' MECHANICAL SECTION - SOUTH ROOMS (MECH, CORRIDOR, EMS, SHOP, SCBA, STORAG SCALE: 1/4" = V-0" III — � ���� 1I- II II ! I I tivaNnn-RaL� II F M _ 101 II II _ [� ®,UL® �UL V I I II o II II UL® �4" 'L ®�UL® �UL 0 — �/L ��UL 0 MECHANICAL SECTION - APP BAY EAST -WEST SCALE: 1/4" = 1'-0" 140 EA 1 • •r• + PI n 0I ------------- -- -------------------I 3 I I I I I I I I I I I I I I I I I j REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 01 2019 PERMIT CENTER 3 4/4/19 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC lamncacnr,,..ua "M . wmw,cv. fe m,ma o xaBaoir � xvre xn � u>ml• JURISDICTIONAL APPROVAL STAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL SECTIONS Sheet M804 0 ce W Z V tA W to Z Q CO ce Ln eV W t� V i owl I n MECHANICAL SECTION NORTH —SOUTH, GRIDLINES 1-3 SCALE: 1/4" = 1'-0" MECHANICAL SECTION NORTH —SOUTH, GRIDLINES 3-7 SCALE: 1 /4" = V-0" n KEVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 U 2019 City Of Tukwila BUILDING DIVISION 2ECEIVED CiT1OF TUKWiLA PEPLIIT CENTER 3 4/5119 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENEUSCH GROUP, INC i uarsncu NoiA ! YECIttxI0I1 t 0:114: AotG told t1E51 21IFEf solo, .f 9FAiilE a ootfo (toe) S/8-06eo (000) Wio-Wl FM Issue REVISED BID SET Date 1/17/2019 Sheet Title MECHANICAL SECTIONS Sheet M Q 05 ill GG w Z v N W n Z Q Co LA H v W F- v El rN II I c �i u) rn W C u, u) LL F- O O m N Z Fi m LL a oo v <r m 0 C- N E:f --------- ::::-: --------- MECHANICAL SECTION NORTH -SOUTH THROUGH GEAR STORAGE, BATHROOM, CORRIDOR AND BUNK ROOM SCALE: 1/4" = V-0" V'0 DOAS DRYER 7"0 DOAE �T TO DOAS � RV-6 RV-7 TO Q4 0 WAS� ITT DOAE 0 DOAE 20/10 RA M 50 14/,0 RA 6"0 DOAS I) X SDI3 150 --42"0 DOAE SA S ,7'0 DOAS Al x_ __..:- _ SA 8/8 SA - lam$ /p� -6/8 RA �Q 150 �4 170 DOAE -1=117 __ 150 �4 150 - _ 150 __TQ4 150 a MECHANICAL SECTION EAST -WEST THROUGH RECEIVING, CORRIDOR, LAUNDRY, BATHROOMS AND CAPTAINS OFFICE SCALE: 1/4" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 08 2019 City of Tukwila BUILDING DIVISION 3 4/5l19 Addendum 9 1B 12111/18 Design Revisions to 12111118 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC �sasnrx a9mo wow a �cxv9c9. ee1+o 1999 NtST MM9�91REEf AwE 911 4'Ai11L 9A 9p119 (9G9) T1E-9619.._ (20E) 3]1-084/ FI% - Issue REVISED BID SET Date 1/17/2019 Sheet Title MECHANICAL SECTIONS Sheet M 8 06 1n W w Z V V) W n z co d1 '1 1n r v w r S V CX i W F M 0�L MECHANICAL SECTION EAST —WEST THROUGH KITCHEN SCALE: 1/4" = V-0" —01 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 8 2019 City of Tukwila BUILDING DIVISION MECHANICAL SECTION EAST —WEST THROUGH ELECTRICAL ROOM, CORRIDOR AND PHYSICAL TRAINING SCALE: 1/4" = V-0" 3 415/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP, INC nw 704 =Me"Mo a ay. owwmmc (z e) 37e-oeeu (-) m- I FM Issue REVISED BID SET Date 1/17/2019 Sheet Title MECHANICAL SECTIONS Sheet n Q 07 N W w Z V In w 0 Z co m -I- N Ce V w H V d I♦, L& THERMOSTATIC MIXING VALVE, LEONARD OR ACCEPTED EQUAL i----CW-- — THERMOMETER--,,--ti[� rr-----HW-----10—tr+-----5 i — HWC BALANCING VALVE, TYP. SHUT—OFF VALVE, TYP. UNION, TYP. CHECK VALVE, TYP. P&T RELIEF VALVE SEISMIC RESTRAINT STRAPS, TYP PROVIDE IN COPPER PIPE TO DRAIN DRAIN PAN PIPED TO DRAIN HOUSEKEEPING PAD, REFER TO ARCHITECTURAL---\- DOMESTIC GAS WATER HEATER DETAIL SCALE: NONE REDUCED PRESSURE BACK —FLOW ASSEMBLY - PRESSURE GAUGE (TYP) STRAINER MAIN SHUT—( TO CW SERVIL, NORMALLY OPEN VALVE EXPANSION TANK VENT TO ATMOSPHERE PRESSURE REGULATOR (2 PSI — 14" WC) CSA RATED FLEXIBLE GAS CONNECTION, VERIFY WITH AHJ PRIOR TO INSTALLATION DIRT LEG 4" COMBUSTION AIR INTAKE/ 4" FLUE EXHAUST, EXTEND AND CONNECT TO ROOF CONCENTRIC VENT ROUTE CONDENSATE TO DRAIN -HOSE END DRAIN VALVE PROVIDE CONDENSATE NEUTRALIZER PER SPECIFICATIONS DRAIN FUNNEL DRAIN TO BUILDING EXTERIOR PRV UNION (TYP) SHUT—OFF VALVE (TYP) r—TO BUILDING GLOBE PRV BYPASS NOTE: CONTRACTOR IS RESPONSIBLE FOR SETTING PRV S TO PROVIDE ADEQUATE FLOW AT MOST REMOTE FIXTURES DOMESTIC WATER SERVICE ENTRANCE DETAIL SCALE: NONE 2—TON LIFT ANCHOR (2 EA. SIDE) INLET PIPE WITH SAMPLING TEE BY OTHERS -a A . o TT 28Ne"I.E. TO BOTTOM t° ' 4"0 INLET PIPE FLOW DIFFUSER ° BAFFLE SEDIMENT WEIR d ""0 INSERT, W/ HEX BOLT (2 EA. SIDE) 7 OUTLET PIPE WITH SAMPLING TEE BY OTHERS OUTLET PIPE 9-Ls OIL RETAINER BAFFLE 3 .04 e . . ° A OIL —WATER SEPARATOR DETAIL SCALE: NONE NOTE: INSTALL PER TF MANUFACTURER INSTRUCTIONS 4"0 EXHAUST AIR PIPING FRO WATER HEATER CONCENTRIC VENT DETAIL SCALE: NONE ROOF 4"0 COMBUSTION AIR PIPING TO WATER HEATER WALL SLEEVE LINK SEAL, WATERTIGHT RMM PRE —INSULATED PIPING UNDERGROUND PIPE SLEEVE THROUGH FOUNDATION WALL DETAIL SCALE: NONE RELIEF VENT CONTRACTOR TO ARRANGE STACK PAY AND INCLUDE COST IN CONTRACT FOR BRINGING RELIEF VALVES GAS TO THE BUILDING AND SETTING THE METER BY—PASS VALVE RELIEF SHUT—OFF VALVE REGULATOR SHUT—OFF VALVE FILTER UUUUUUu ° ° ° ° , SHUT—OFF DIAPHF VALVE � o METER BY—PASS VALVE " " " ° ° " ADJUSTABLE METER STAND GAS METER ASSEMBLY DETAIL (DIAPHRAGM TYPE) SCALE: NONE WALL ACTUATED SHUT—OFF VALVE FIELD SUPPLIED FUEL LINE OR RAINWATER CK PLUG TEE ANITARY SEWER/ R LEADER PIPE AS —ON ING SANITARY SEWER OR RAINWATER DRAINAGE PIPE FLOW LY SANITARY SEWER/ RAINWATER LEADER STACK CLEANOUT DETAIL SCALE: NONE FLOOR DRAIN TROUGH 4 4 d 4 4 PROVIDE VENTED AND PRIMED TRAP TROUGH DRAIN T-2 SIDE VIEW TROUGH LID, PROVIDE OPENINGS AT DRAIN PIPE LOCATIONS INTEGRAL LINT FILTER V I Q q lJ 4 � I a Q I d 4 d t . Q AUJ City o BUILDINTO BUILDING SEWRECITY OAo 3 4t4119 Permit Revision 18 12/11/18 Design Revisions to 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG 11 '''' ••a a �����`L�uFiti1 :.,� JURISDICTIONAL APPROVALSTAMP Issue MECHANICAL PERMIT Date 7t25t2019 Sheet Title MECHANICAL DETAILS Sheet M 901 i a SPRINKLER SYSTEM DRAIN TWO DRAIN PIPE DIAMETERS PROVIDE L4" SCREEN MESH CAP FOR RODENT PROOFING PER UPC 312.12. 36" MIN 6" DIAMETER STAND PIPE DRAIN 42" MINI MINIMUM 4" DRAIN TO SANITARY —� FINISHED FLOOR STANDPIPE DRAIN DETAIL SCALE: NONE AIR GAP DISHWASHER WATER HAMMER ARRESTOR DEVI DISHWASHER CONNECTION DETAIL SCALE: NONE SINK COUNTER WATER HAMMER ARRESTOR DEVICE VENT TO ROOF 2WT0 � SEWER --,\--th"CW SUPPLY P—TRAP LVz"HW SUPPLY ?A" WASTE FLEX HOSE (TYP) CONNECT TO NEAREST FREQUENTLY USED FIXTURE'S WATER SUPPLY, OR NEAREST CW LINE TO FIXTURE (OR AS SHOWN) TIMER BOX — 115 VOLTS, PROVIDE UNISTRUT t ASSEMBLY TO SUPPORT BOX SOLENOID VALVE TRAP PRIMER VALVE ACCESS DOOR, SIZED TO ALLOW UNOBSTRUCTED ACCESS TO COMPONENTS, PRIMER MANIFOLD (S) MIN. 16" X 16" (WHERE SERVING MORE THAN ONE FLOOR DRAIN) 6' SOLENOID CONTROL CABLE L i t -%"CW (TYP) ( i FINISHED FLOOR TRAP PRIMER DETAIL SCALE: NONE CLEANOUT PLUGS & AT EACH CHANGE IN DIRECTION TOWARDS DISCHARGE FULL SIZE VENT (OPEN END) -� TO FLOOR DRAIN TRAP (TYP) DRAIN LINE PIPING SHALL NOT INTERFERE WITH ACCESS TO EQUIPMENT � Apl__ B" LL EQUIPMENT DRIP PAN 45 DEG CUT WHEN ROUTED TO COUPLING OR UNION FOR LONG FLOOR DRAIN DRAIN LINES. SPILL TO DRAIN OR CONNECT TO ROUTE DRAIN PIPING TO NEAREST DRAIN FIXTURE TAIL PIECE FIXTURE TAIL PIECE OR FLOOR DRAIN AS SHOWN ON PLAN. SIZE SHALL BE FULL SIZE "A" SHALL BE EQUAL TO THE OF UNITS DRAIN OUTLET OR 1V4", WHICHEVER PLENUM NEGATIVE STATIC IS GREATER. "B" SHALL BE EQUAL TO 1/2 THE PLENUM MAXIMUM NEGATIVE STATIC PRESSURE TRAP AT CONDENSATE DRAINAGE PIPING SCALE: NONE PACK WITH FIBERGLASS INSULATION 2" MIN. WEATHERTIGHT COVER WITH INSECT SCREEN CAULK WEATHERTIGHT 12 2 REFRIGERANT AND GAS PIPING THROUGH ROOF DETAIL SCALE: NONE 24 GAUGE GALVANIZED ROOF CAP PIPING COUNTER FLASHING ROOF PROVIDE WIDTH AS REQUIRED TO ALLOW LONG RADIUS BEND. PROVIDE LENGTH AS REQUIRED GAS VENT PIPE, SIZED PER PLAT` PROVIDE TWO 90' ELLS AT VENT TERMINATION TO PREVENT RAINWATER PENETRATION d COLLAR 1 CONE FLASHING TO GAS PRESSURE REGULATOR GAS REGULATOR VENT TERMINATION AT ROOF SCALE: NONE T U SHUT OFF DIRT LEG COMPRESSED AIR u REEL r r OLD WATER i LL J —SPILL RESISTANT, '"� PRESSURE VACUUM r BREAKER U COMPRESSED AIR HOSE REEL & COLD WATER HOSE REEL DETAIL SCALE: NONE V'4" HOT WATER SUPPLY THREADE FILTER, 9 WASHER —EXTRACTOR WATER CONNECTIONS DETAIL M902 SCALE: NONE -Y4"COLD WATER SUPPLY AIR CUSHION RISER/HAMMER ARREST DEVICE, TYP SHUT—OFF VALVE, TYP REVIEWED FOR CODE COMPLIANCE CHECK AS 3EMBIL&OMOVED VACUUM BREAK AUG 08 2019 City of Tukwila FILTER, BUILDING DIVISION RECEIVED CITY OF TUKWILA 3 4/4119 Permit Revision 1B 12/11/18 Design Revisions IA 12M 1/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP. INC ica Ms Llw ,meo t MWWWA niarmua 120.4 00sms4mce-oe,aF"u° JURISDICTIONAL APPROVAL STAh1P Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL''. DETAILS', Sheet I V I902} Ln cz w Z v 7A W 0 Z d m n: + H U H S U <C pal —J 1r AIR COMPRESSOR DETAIL SCALE: NONE %" ALLTHREAD, ATTACH SECURLEY TO STRUCTURE (TYP) vFLAT WASHER W/ HEX NUT (TYP) SEISMIC SWAY CABLE PER SMACNA, ANCHOR SECURELY TO STRUCTURE, (TYP). CW, HW, HWC CHANNEL STEEL SUPPORT, 1 %"xl %"x12 GA FLAT WASHER WITH (2) HEX NUTS (TYP) PIPE, SHIELD WITH HEAVY DENSITY INSULATION OR PROTECTION SADDLE PIPE SUPPORT TRAPEZE DETAIL SCALE: NONE STEEL ANGLE, 2x2x.125 SPAN STRUCTURE AND SECURE, COORDINATE INTERMEDIATE EA STEEL MEMBERS AND ATTACHMENT REQUIRED WITH TO COMBINED COMBUSTION BUILDING CONTRACTOR AIR/VENT, SEE 2x2x.125 STEEL ANGLE 90 HANGERS AND SEISMIC CROSS BRACING VENT TO ATMOSPHERE, STEEL ANGLE, 2x2x.125 BOLT TO UNIT HEATER SEE 3 SUPPORT POINTS UNIT 90 HEATER ADJUST DIRECTIONAL PRESSURE REGULATOR VANES FOR THROW _ G (2 PSI — 14" WC) SEE ARCHITECTURAL FOR INSTALLED HEIGHT ABOVE FLOOR GAS UNIT HEATER DETAIL SCALE: NONE �_DIRT LEG AGA RATED BALL SHUT-OFF VALVE GAS FLEX CONNECTOR SIDE VIEW PREFABRICATED TRENCH DRAIN SECTION SLOPE TO DRAIN -- -- SLOPE TO DRAIN WASTE CONNECTION 'may SECTION VIEW REFER TO ARCHITECTURAL FOR FINISH TRENCH DRAIN 4" CONCRETE SLAB -- ° ; :. ` .4 . :. --4" CONCRETE SLAB DETAIL NOTES: 1. SET TRENCH DRAIN IN ` CHANNEL SURROUNDED BY 6" OF CONCRETE WITH A a "` ' tm� MINIMUM OF 3,500 P.S.I. SLOPE CONCRETE OFF THE " TOP OF AND AWAY FROM a .� THE DRAIN. WASTE CONNECTION & P—TRAP NOT SHOWN 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. TRENCH DRAIN TD-1 DETAIL SCALE: NONE 0 LUG MACHINE BOLT AT END OF ANGLE — PIPE INSULATION AND COVERING — SEISMICALLY SUPPORTED CLEVIS HANGER DETAIL SUPPORT ROD (SHOWN) WITH ROD STIFFENER. CABLE INSTALLED SLACK ADJUSTING NUT UL LISTED CLEVIS HANGER PIPE SHIELD WITH PROTECTION SADDLE INSTALL INTERNAL WATERGUARD IN ALL INSULATED ROOF, SEE ARCHITECTURAL OVERFLOW ROOF DRAINS POLYPROPYLENE DOME, TYP FLASH ROOFING INTO DRAIN, TYP DRAIN RECEIVER, TYP " NO —HUB CONNECTOR, TYP CLAMPING RING — INSULATE AROUND ENTIRE DRAIN ASSEMBLY, TYP. FOR CONDITIONED SPACES CLEANOUT, TYP ORL, SIZE 1A PER PLANS RAINWATER LEADER, COMBINE IN VERTICAL, TYP — ROOF DRAIN DETAIL SCALE: NONE SECTION INSULATION (TYP) STRUT BODY PIPE STRUT PIPE ITYP) CLAMP Ir ANCHOR STRUT SECURELY TO DOCK PIPE SUPPORT WALL MOUNT DETAIL SCALE: NONE M903 SCALE: NONE EXHAUST TERMINAL ABOVE ANY SEAL WITH HIGH TEMPERATURE SILICONE S SURFACE WITHIN U RUBBER SEALANT SUPPLIED WITH KIT 10 FEET COMBUSTION AIR INLET FLUE EXHAUST PIPE FLASHING 11 18" MIN. 4' MAX. ROOF (� COMBUSTION AIR PIPE ROOF IS COMBUSTIBLE CONCENTRIC ADAPTER, ATTACH TO ROOF WITH BRACKETS 1 } 1 I FLUE EXHAUST PIPE COMBUSTION AIR PIPE UNIT HEATER COMBUSTION AIR VENT DETAIL SCALE: NONE wor'm 0�c I I INSULATION V/_PIPE 3 414/19 Permit Revision 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP. INC Acowrov. MIDI l=a rmuwnv, DIONE " i3i1eM-oeeuN ) 37e-oe 1�Fix JURISDICTIONAL APPROVALSTAMP Issue MECHANICAL PERMIT Date 7/25/2019 Sheet Title MECHANICAL DETAILS Sheet M903 l J " LO ROOFTOP EQUIPMENT CURB, FLASHING AND COUNTER FLASHING, SEE E CANT STRIP — ROOFING ROOF DECK R38 RIGID INSULATION INSIDE CURB CAVITY — DUCT PENETRATION, OPENING NOT TO EXCEED DUCT DIMENSIONS +2" — TYPICAL ROOFTOP EQUIPMENT CONNECTION DETAIL SCALE: NONE CONDENSATE, ROUTE TO DRAIN PER MECHANICAL PLANS - IRS, RL REFRIGERANT PIPING FROM OUTDOOR VRF IRS, RL REFRIGERANT PIPING LINES TO VRF INDOOR UNITS, TYP — ATTACH HANGER ROD SECURELY TO STRUCTURE, TYP— RS, RL REFRIGERANT PIPING FROM OUTDOOR VRF UNIT CONDENSATE, ROUT TO DRAIN PER MECHANICAL PLANS DUCT TRANSITIONS FROM EQUIPMENT TO DUCT HATCHED AREA INDICATES CLEARANCE SPACE PER MANUFACTURER r — — — — —I MAINTENANCE ACCESS HATCH, / \ COORDINATE WITH ARCHITECTURAL DRAWINGS CONTROL BOX T- r 1111111111111111 PLAN VIEW VIBRATION ISOLATORS, MASON ZM=30N OR EQUAL IRS, RL BC-1 REFRIGERANT PIPING TO BRANCH CEILING CONTROLLER BC-2 MAINTENANCE ACCESS HATCH, SHOWN IN OPEN POSITION. COORDINATE WITH ARCHITECTURAL DRAWINGS L_--- __J ELEVATION VIEW NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. BRANCH CONTROLLER BC-2 INSTALLATION SIMILAR BUT UNCONCEALED. BRANCH CONTROLLER DETAIL SCALE: NONE CURB STRUCTURE, STEEL CHANNEL OR WOOD _.. CANT STRIP CURB FLASHING DETAIL SCALE: NONE SPRING & NEOPRENE VIBRATION ISOLATOR, TYPICAL, MASON 30 N OR EQUAL THREADED ROD HANGER---\ CONDENSATE PIPING. TRAP AND EXTEND FULL SIZE TO DRAIN FIXTURE SUPPLY DUCTWORK TRANSITION FROM UNIT TO DUCT SIZE INDICATED ON PLAN FLEXIBLE CONNECTION TO DUCT, TYPICAL— VRF UNIT, COORDINATE INSTALLATION HEIGHT WITH ARCHITECT SHEETMETAL COVER WITH RECEIVER FOR COUNTERFLASHING HIGH —DOMED, CAPPED, GASKETED FASTENERS (APPROX. 18" O.C., DEPENDING UPON LOCAL WIND ZONE AND LOCAL CONDITIONS SHEETMETAL COUNTERFLASHING FASTENERS, APPROX. 8" O.C. OPTIONAL: EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT ROOFING ROOF DECK RL, IRS PIPING, SIZE PER MITSUBISHI CITY MULTI SYSTEM AND CONTROL DIAGRAM, SEE I M 700 DUCTED VRF UNIT (IDU) DETAIL SCALE: NONE EXTERIOR WALL SEAL WEATHERTIGHT- WALL LOUVER — SECURE LOUVER TO FRAMING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS — WALL LOUVER DETAIL SCALE: NONE SUPPORT ANGLE INSULATE DUCT AND PLENUM CONNECTIONS 1/4"x 1/4" SCREEN TRANSITION TO DUCT OR SOUND TRAP MOTORIZED DAMPER COORDINATE FINAL HEIGHT WITH ARCHITECT SUSPEND SECURELY FROM STRUCTURE, REFER TO VRF SCHEDULE FOR UNIT WEIGHTS SEISMIC SWAY BRACING AND RESTRAINTS, ALL 4 SIDES PROVIDE ACCESS TO CONTROL BOX, MOTOR AND FAN PER MANUFACTURER'S WRITTEN INSTRUCTIONS POWER ROOF EXHAUSTER EXHAUSTER BASE & COUNTER FLASHING ARCHITECTURAL CURB ROOF DECK—\ EXHAUST DUCT ROOF EXHAUST FAN DETAIL SCALE: NONE BIRD/INSECT SCREEN SEE SCHEDULE FOR TYPE INSULATED ROOF STORM PROOF BLADES — GASKET LAG SCREW CURB, FLASHING AND COUNTER g FLASHING, SEE M\ ROOFING BY GEN. TRADES --- SEAL OPENING DUCT INSULATION RELIEF DUCT — ROOF VENTILATOR DETAIL SCALE: NONE BIRD SCREEN GASKET LAG SCREWS CURB, FLASHING AND COUNTER 2 FLASHING, SEE ( 904 ROOFING BY GEN. TRADES I INSULATED PREFABRICATED CURB WITH RAISED CANT, NAILER & ROOF FLANGE SEAL OPENING MOTOR OPERATED DAMPER LOUVER HOUSE (RELIEF HOOD) 12" `—INSULATED PREFABRICATED CURB WITH RAISED CANT, NAILER AND ROOF FLANGE MOTOR OPERATED DAMPER _'"'---..� PUMPED REFRIGERANT LIQUID AND CONDENSATE SUCTION LINES TO DRAIN LINE BRANCH CONTROLLER _ BACK VRF UNIT, WALL MOUNTED FRONT 1Yn" CONDENSI TERMINATE AT COORDINATE ELEVATION DRAIN OR NEP ABOVE FINISHED FLOOR SINK TAILPIECE WITH ARCHITECT WALL MOUNTED VRF UNIT (IDU) DETAIL SCALE: NONE REVIEWED FOR LCODE COMPLIANCE FUNNIAPPROVED ;EST AUG 0 8 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA PEPMIT CENTER 3 4/5/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11118 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP. WC anus+ . temo wmru a mxwOL DMEMM Issue REVISED BID SET Date 1/17/2019 Sheet Title MECHANICAL DETAILS Sheet M 9O4 Ln ad UJ V tn w 0 Z d co ad + V) V w H V rY ►J t DISCHARGE DISCHARGE AIR AIR � PUMPED INTAKE AIR INTAKE AIR REFRIGERANT LIQUID — AND SUCTION LINES CONDENSATE DO U-V ODU-V TO �s DRAIN LINE, TERMINATE R CONDENSATE GRAVITY DRAIN ANTI -VIBRATION PAD WITH STEEL BACK PROVIDE UNIT PLATE AND FRICTION PAD, CLEARANCES AND MASON INDUSTRIES MBSW OR MOUNT PER ACCEPTED EQUAL MANUFACTURER'S ' WRITTEN INSTRUCTIONS RS & RL, MAKE FLEXIBLErx O SLEEPERS, MOP OR ROOF INTO MEMBRANE. AC INDOOR UNIT, 1Ya" CONDENSATE TERMINATE AT FUNNEL BY SECURING WITH PIPESECURE TO STRUCTURE BELOW. WALL MOUNTED CLAMP OVER INSULATIONPROVIDE METAL FLASHING CAPS. FRONT DRAIN PER PLANS COORDINATE FLASHING DETAILS WITH ARCHITECT ROOF DECK X PROVIDE 20 GAUGE SHEETMETAL VANDAL RESISTANT COVER FOR ABOVE GROUND RS & RL RS & RL TO BRANCH CONTROLLER VRF OUTDOOR UNIT DETAIL AC INDOOR UNIT DETAIL 1 2 M905 SCALE: NONE O5 SCALE: NONE I DRYER VENT DETAIL SCALE: NONE MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL INTERMEDIATE STEEL AS NECESSARY. COORDINATE WITH STRUCTURAL ADJUST LENGTH TO \ INSTALL DIFFUSER AT HEIGHT SPECIFIED BY ARCHITECT EXPOSED ROUND DUCT DETAIL SCALE: NONE GASKET LAG SCREWS INSULATED CURB WITH RAISED CANT, NAILER & ROOF FLANGE ROOFING BY GEN. TRADES SECURE TO STRUCTURE , T1 HEAT RECOVERY VENTILATOR DETAIL SCALE: NONE ACCESS PANEL"^,V� INSULATED MAIN INSULATED SHEET SUPPLY DUCT METAL DUCT i INSULATED FLEX DUCT INTERMEDIATE STEEL 3 OR STRUCTURE DETAIL NOTES: 2 4 AIRCRAFT CABLE SQUARE —TO —ROUND TRANSITION d EARTHQUAKE BRACING ACCESSORY WHERE USED. 5 SUSPEND DUCT BY COMPRESSION STRAP ON FLEX THREADED ROD DUCT TO INSURE AIRTIGHT JOINT. MAIN SUPPLY DUCT, VOLUME DAMPER OUT OF MAIN 2 1 SPIRAL WOUND SUPPLY DUCT. 4 DIFFUSE , SPACE X "D'AVAILABLEICEILING DIFFUSER. MIN 1.5 X "D" STRAIGHT " IS SUPPLY DUCT SIZE TO� INSULATED FLEX DUCT, MAX T BAR LENGTH OF FLEX DUCT TO BE 5 FEET, SEE GENERAL NOTES. CEILING DIFFUSER CEILING DIFFUSER DETAIL SCALE: NONE AIR NOTES: 1. PROVIDE UNIT CLEARANCES PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS 2. DO NOT DAMAGE EXISTING STRUCTURE WHEN INSTALLING, AC OUTDOOR UNIT DETAIL SCALE: NONE STRUT FOR FAN CONTRACTOR. C( WITH STRUCTURE PROVIDE EXTEND SEE MANUFACTU CEILING FAN DETAIL SCALE: NONE AIR DISCHARGE FAN ELECTRICAL TERMINAL BLOCK TRANSPORTING HANDLE PROVIDE 20 GAUGE SHEETMETAL VANDAL RESISTANT COVER OVER ABOVE GROUND RS & RL RS & RL, MAKE FLEXIBLE BY SECURING WITH PIPE CLAMP OVER INSULATION RS & RL TO BUILDING, CORE DRILL AS REQUIRED. FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING REFRIGERATION PIPING. JOISTS 4NOPY, STRUCTURE BEAM INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. COORDINATE INSTALLATION HEIGHT AFF WITH ARCHITECT NOTES: PROVIDE ATTACHMENTS PER SEISMIC ZONE 3 REQUIREMENTS. 3 415/19 Addendum 9 18 12111/18 Design Revisions to 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 17915 Southcenter Parkway Tukwila, WA 98188 Project No. 17001 Designed by JWG Drawn by JA Checked by JWG THE GREENBUSCH GROUP. INC �mustr.sma tmaty 1 mm a Kx BMW" tY00 t1E4f RITE IDt gAntE a will '.. (toe) see-oeav (M) me -MI t•Nt Issue REVISED BID SET Date 1/17/2019 Sheet Title MECHANICAL DETAILS Sheet M 905 to 04 w Z V rn w 0 Z co m Ce -I- N V H S V 20 W, J '.J R' L 1, I