Loading...
HomeMy WebLinkAboutPermit M19-0105 - HOMEGROWN - ONE SPLIT SYSTEM HEAT PUMP WITH DUCTWORK AD DIFFUSERS AND EXHAUST FANHOMEGROWN AT SOUTHCENTER 841 SOUTHCENTER MALL M19-0105 Parcel No: 0 ��^�xx m�� Tukwila ~~U~� v�n v ��m^���na Department of Community Development 63OVSouthcenterBoulevard, Suite #1OU Tukwila, Washington 98188 Phone:306'431'3670 Inspection Request Line: 206'438'9350 Web site; http://www.TukwilaWA.gov 9202470010 84lSOUTH[ENTERMALL MECHANICAL PERMIT Project Name: HOMEGROWN AT SOUTHCENTER Permit Number: K419'0105 Issue Date: 7/31/2019 Permit Expires On: 1/27/2020 WESTFIELD PROPERTY TAX DEPT PO BOX 13O94O'Q0B��WA, 92013 Contact Person: Name: JER[MY[NUEUBR Phone: (425)821,1Z93 Address: P0VOK3ZO5'K|RKLAND'VVA 98O83 Contractor: Name: [F[NHEATING AND [ODUNGINC Phone: (425)821'1293 (GENERAL) Address: POBOX JZO5,K|RKLAND,VVA 98083 License No: CF�NHEH[969[D Expiration Date: 2/27/2020 &ddress P0VOK3ZO5'K|RKLAND'VVA 98O83 Lender: Name: A ddress: .,, DESCRIPTION REFRIGERATION EQUIPMENT FOR WALK IN COOLER IS NOT PART OF THIS PERMIT, BY OTHERS. DFWORK: INSTALL ONE SPLIT SYSTEM HEAT PUMP WITH DUCTWORK AND DIFFUSERS AND I INTERIOR EXHAUST FAN. Valuation of Work: $25,000.00 Type ofWork: REPLACEMENT Fuel type: ELECT Fees Collected: $54656 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKVV|LA Sewer District: TVKW|L4 Current Codes adopted bythe City ofTukwila; international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: t Center Authorized Signatu 2015 20152015 2015 2015 National Electrical Code: WA State Energy Code: VVACities Electrical Code: VVA[296-46B: 2017 2017 / �/ � ��' L��� |hearbycertify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction or the performance of work, I am authorized to sign and obtain this development permit and agree tothe conditions attached to this permit. Signature: Print Name: 6 oca,',,�eyj,y 4k,k~— Date:/77�/_/q This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS; 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion ofthis requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ufTukwila Building Department (ZDG-43l'367O). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance orgranting ofaperm, itshall not beconstrued tobnapermit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances cfthe City ofTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: `MECHANICAL PERMIT [ONDOnONS^~* 9; All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (ZO§/43l'367U). 10: Manufacturers installation instructions shall beavailable nnthe job site atthe time ufinspection. ll: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto-sh utdown devices. These devices shall be separately zoned in the alarm panel and local U,L. central station supervision is required, (City Ordinance #Z437) 13: H.V.AI.symtams supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall beequipped with anautomatic shutoff. Automatic shutoff shall beaccomplished byinterrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions, (|K8[6O6.1,606.2.l) 14: Remote indicator lights are required onall above ceiling smoke detectors. (City Ordinance #Z437) 15: Duct detectors shall send asupervisory signal only upon activation, (City Ordinance 4Z437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. q Project No. Date Application Accepted: 67— ?"4—/ Date Application Expires: - (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Cr z.02.1700n Site Address: ?sit 50 WO\ Ce.Aier heak Suite Number: 552 Floor: Tenant Name: ki0Inet,5rOug—' PROPERTY OWNER Name: Wesk,c i eQ, L LC Address: 1800 5. L4‘, c.n.ier M.4 q City: - \c State: vliA Zip: ?et 86 CONTACT PERSON — person receiving all project communication Name: Address: Rot boK 32a5 City: State: Zip:96083 y.. , Phone: /05_ bz 1 ,rzis F . ax:42.5., Eat, 11.3q5 Email: ,:jefemve c r 14_ gvi4(i2 , cog New Tenant: Yes ..No MECHANICAL CONTRACTOR INFORMATION company Name: C F M 14 egritc6 cod CobtinOk Address: i31.0. .6104. 3205 City: y..,. State: wA Zip:18065 Phone:1425, 62,1_12(13 Fax: 1,./25., f3e.i, 6,13 Contr Reg No.: c FmtioAcivez, Exp Date:0,4174 12.0 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 25,000 Describe the scope of work in detail: ano-44 54 k-en.\ ' c\:--Lfzers coc), 1R1ec or elle.(464- kcl (co\ti NO1 ? LA 1Ats ()fermi+ib c4lett Use: Residential: New E Replacement Commercial: New Replacement J:1 EA.Okik &,druovf.. eiurms\- 4( ac Fuel Type: Electric ID Gas ....... 0 Other: HAApplicacions\ Forms -Applications On Line \2016 ApplicationsNechanical Permit Application Revised 1-4-16.docz Revised: January 2016 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm k Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 htu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h ,750.000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; Construction and property maintenance during the daytime hours (7am-l0pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: 'TL 274ve,(J`' / Print Name: ex-en1.4 frIce,.. Signature: Mailing Address: PO. 5DY 3205— Dale: 06-2(.1 15 Day Telephone: /21 K r Won( IAA 'Mom Statc Zip RAkpplications\Forrns-Applications On Line \20 16 Applications \Mechanical Permit Application Revised 1.4.16.cloca RevisedJanuary 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $546,56 M19-0105 Address: 841 SOUTHCENTER MALI Apn: 9202470010 $546.56 Credit Card Fee $15.92 Credit Card Fee R000.369.908.00.00 0,00 $15.92 MECHANICAL $510.23 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $375.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $102.05 TECHNOLOGY FEE $20.41 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17984 R000.322.900.04.00 , 0.00 $20.41 $546.56 Date Paid: Monday, June 24, 2019 Paid By: JEREMEY MOELLER Pay Method: CREDIT CARD 714212 Printed: Monday, June 24, 2019 3:21 PM 1 of 1 YSTEM5 CO TUKWILu ETRAKIT 6200 S0UTH[ENTEK 8LVD TUKWILA, WA 98188 206'433'1870 CITY OF TuKWILA 8017348000802374464508 Date: 06/24/2019 03:21:05 PM CREDIT CARD SALE VISA CARD NUMBER: **********9056 K TRAN AMOUNT: $546.58 APPROVAL [D: 714212 RE[0KO #: 000 CLERK ID: kandace X {CARDHOLDER'S SIGNATURE} I 46nss TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT Thank you! Merchant Copy INSPECTION RECORD Retain a copy with p ermit P4 (OIZ�T INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type f spe on: Addre s: cd ate Called: Special Instructs ns: ,e-Z._ Date Wanted: A z, a.m. p.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. - Ota INS TION RECORD ain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 670 Permit Inspection Request Line (206) 438-9350 P ct: Type pect-ion: A dress: Date Called: Specsai lnstructions: Date Wanted: a.m. • Requester Phone No: EjApproved per applicable codes. nspec Corrections required prior to approval. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee musi be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspeclion. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Pr ject: _ "� '� Typo of inspection: • f+/► "Ir ray r . I► ', Al - i a.m. p.m. Address: 'r+ Da .- Calle ��►: « .4��..� Special Instructions: Date Wanted: JO/ ZI !Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. NSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: . �T f i pectio : R o As�: f Date ailed: Special Instructions: 7Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. npector: Date: • REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 4.31--3670 Permit Inspection Request Line (206) 438-9350 M)9O/5' Proj c Tyns' ction: Special Ins ructions: Dal 'tame = a.m.. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. Inspector: t j 1 lam' IDate: REINSPECTION FEE REQUIRED. Prior to next insp - ction. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ct: aill, ey ` of Inspec ion: 1:_r_to otaztie A dress: f a e Called. Special Instructions: 0a a Wanted: a.m. p-m- Requesier hone proved per applicable codes. COMMENTS ections required prior to approval. nspecto REINSPECTION FEE REQUIRED. Prior to next inspe ' = n, fee must be paid at 6300 Southtenter Blvd., Suite 100. Call to schedule reinspection. CFM HEATING & COOLING, INC. PO Box 3205 Kirkland, Washington 98083 Phone: 425-821-1293 Fax: 425-821-1343 rProje t: rvs% e S-D Location AIR OUTLET — TES1 REPORT H.V.A.C. System or Unit: {Outlet Manufacturer: 1 AREA SERVED No. OUTLET TYPE SIZE DESIGN CFM PRELIMINARY CFM FINAL CFM Li 0 0 il 00 '. CS S 4 ao Li in (ID •)_)-c rQs0 a:z'N 0 7 •C 1 300 3 a.'s 1 o 3 oo 3 a 5 ,RE(Fivr:: CITY OF TUKW A 0CT292619 )ERMtT CENTER NOTES: TEST DATE: J cD - lc\ READINGS BY: PAGE OF PEtvT COORD GOP? PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0105 DATE: 06/24/19 PROJECT NAME: HOMEGROWN AT SOUTHCENTER SITE ADDRESS: 841 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: S A -COL (1) Building Division Public Works kl\A IC\N° Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: Planning Division Permit Coordinator DATE: 06/25/19 Structural Review Required DATE: LI APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues DUE DATE: 07/23/19 Approved with Conditions ri Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 0 Ping PW D Staff Initials: 12/18/2013 Hunt?, Espanol Contact Safety & Health Claims & Insurance hington State Department of Labor & Industries A-i: Index Help My Workplace Rights Trades & Licensing C F M HEATING AND COOLING INC Owner or tradesperson Principals CLANCY, SHAUN P, PRESIDENT Doing business as C F M HEATING AND COOLING INC WA UBI No. 602 361 244 PO BOX 3205 KIRKLAND, WA 98083 425-821-1293 KING County Business type Corporation Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Not allowed to have apprentices. License Verify the contractor's active registration / license / cert Construction Contractor License specialties GENERAL License no. CFMHEHC969CD Effective — expiration 02/04/2004— 02/27/2020 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 798903C ion (depending on trade) and any past violations. Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/17/2008 02/04/2009 Expiration date Until Canceled Insurance ... AMERICAN FIRE & CASUALTY CO $1,000,000.00 Policy no. BKA54333410 Received by L&I Effective date 01/22/2019 02/04/2011 Expiration date 02/04/2020 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Help us improve ��uc•»��:3c3c��•na�rr• ® AT ID INSIDE DIAMETER (L CENTERLINE IN INCH R PROPERTY LINE INCL INCLUDED 6 DIAMETER INSUL INSULATION POUND OR NUMBER TNT INTERIOR E} EXISTING INV INVERT (hl NEW JB JUNCTION BOX AB ANCHOR BOLT JF JOINT FILLER ABV ABOVE JT JOINT ACC ACCESS KIT KITCHEN ACOUS ACOUSTICAL KO KNOCKOUT ACP ASPHALT CONCRETE PAVING LAM LAMINATE; LAMINATED ACS ACCESS PANEL LAV LAVATORY ACT ACOUSTICAL TILE LBS POUNDS AD AREA DRAIN LF LINEAR FOOT (FEET) ADA AMERICANS with DISABILITIES ACT LH LEFT HAND ADJ ADJUSTABLE LL LIVE LOAD AFF ABOVE FINISHED FLOOR LOC LOCATION AGGR AGGREGATE LP LOW POINT AIB AIR INFILTRATION BARRIER LT LIGHT ALT ALTERNATE MAS MASONRY ALUM ALUMINUM MAIL MATERIAL APPROX APPROXIMATE MAX MAXIMUM ARCH ARCHITECTURAL; ARCHITECT MB MACHINE BOLT ASPH ASPHALT MC MEDICINE CABINET AUTO AUTOMATIC MDF MEDIUM DENSITY FIBERBOARD BD BOARD MDO MEDIUM DENSITY OVERLAY BITUM BITUMINOUS MECH MECHANICAL BLDG BUILDING MEMB MEMBRANE BLKG BLOCKING MEZZ MEZZANINE BM BEAM MFR MANUFACTURER BUT BOTTOM OF MIN MINIMUM GOT BOTTOM MISC MISCELLANEOUS FIRS BEARING MO MASONRY OPENING BSMT BASEMENT MID MOUNTED BUR BUILT UP ROOFING MTL METAL CAB CABINET MUL MULLION CB CATCH BASIN N NORTH CEM CEMENT N/A NOT APPLICABLE CER CERAMIC NIC NOT IN CONTRACT CIP CAST -IN -PLACE NO NUMBER CJ CONTROL JOINT NOM NOMINAL CLG CEILING NR NOISE REDUCTION CLK CAULKING NIS NOT TO SCALE CLO CLOSET GA OVERALL CLR CLEAR GC ON CENTER CMU CONCRETE MASONRY UNIT OD OUTSIDE DIAMETER; CNTR COUNTER OVERFLOW DRAIN COL COLUMN OFF OFFICE CONC CONCRETE OH OVERHEAD CONN CONNECTION OHWM ORDINARY HIGH WATER MARK CONST CONSTRUCTION OPNG OPENING CONT CONTINUOUS OPP OPPOSITE CONTR CONTRACTOR OSB ORIENTED STRAND BOARD CORR CORRIDOR POO PARTICLE BOARD CPT CARPET; CARPETED PCC PRECAST CONCRETE CRS COLD ROLLED STEEL PCF POUNDS PER CUBIC FOOT CSK COUNTERSUNK PERF PERFORATED CT CERAMIC TILE PERP PERPENDICULAR CTR CENTER Pl. PLATE CU FT CUBIC FEET PLAM PLASTIC LAMINATE DBL DOUBLE PNL PANEL DEMO DEMOLITION PNT POINT DET DETAIL POS POINT OF SALE DIA DIAMETER PR PAIR DIM DIMENSION PRCST PRECAST DL DEAD LOAD PSF POUNDS PER SQUARE FOOT DN DOWN PSI POUNDS PER SQUARE INCH DR DOOR PIN PARTITION DS DOWNSPOUT PVC POLYVINYL CHLORIDE DSP DRY STANDPIPE PWD PLYWOOD DIN DISHWASHER R RISER DWG DRAWING RA RETURN AIR E EAST RAD RADIUS EA EACH RB RUBBER BASE EJ EXPANSION JOINT RD ROOF DRAIN EL ELEVATION REF REFERENCE ELEC ELECTRICAL REFR REFRIGERATOR ELEV ELEVATOR REG REGISTER ENCL ENCLOSURE REINF REINFORCED EQ EQUAL REM REMAINDER EQUIP EQUIPMENT REQ REWIRED EST ESTIMATE RESIL RESILIENT EW EACH WAY REV REVISION; REVISIONS; REVISED EXH FN EXHAUST FAN RGIR REGISTER EXIST EXISTING RH RIGHT HAND EXP EXPANDED; EXPANSION RM ROOM EXP BT EXPANSION BOLT RO ROUGH OPENING EXPO EXPOSED RVP RADON VENT PIPE EXT EXTERIOR RWL RAIN WATER LEADER FA FIRE ALARM S SOUTH FB FLAT BAR SAF SELF -ADHERED FLASHING FD FLOOR DRAIN SAM SELF -ADHERED MEMBRANE FE FIRE EXTINGUISHER SC SOLID CORE FEC FIRE EXTINGUISHER CABINET SCHED SCHEDULE FF FINISH FLOOR SO SMOKE DETECTOR FF EL FINISH FLOOR ELEVATION SECT SECTION FIT FIRE HYDRANT SF SQUARE FOOT (FEET) FHC FIRE HOSE CABINET SG SAFETY GLASS FF FINISH TO FINISH SHR SHOWER FIN FINISH SIFT SHEET FLASH FLASHING SIFT MTL SHEET METAL FUR FLOOR; FLOORING SHTG SHEATHING FLUOR FLUORESCENT SHV SHELF; SHELVING FO FACE OF... SIM SIMILAR FOC FACE OF CONCRETE SOG SLAB ON GRADE FOF FACE OF FINISH SPEC SPECIFICATION FOIC FURNISHED BY OWNER- SO IN SQUARE INCH(ES) INSTALLED BY CONTRACTOR SST STAINLESS STEEL FOM FACE OF MASONRY STD STANDARD FOS FACE OF STUDS STL STEEL FPL FIREPLACE STOR STORAGE FIR FRAME STRUCT STRUCTURAL FRPF FIREPROOF SUSP SUSPENDED FRT FIRE RETARDANT TREATED SYM SYMMETRICAL FRZR FREEZER T TREAD FT FOOT OR FEET T&G TONGUE AND GROOVE FIG FOOTING TB TOWEL BAR FURR FURRING TEL TELEPHONE FLIT FUTURE TER TERRAllO Fill FULL WIDTH TO TEMPERED GLASS GA GAUGE THK THICK GALV GALVANIZED TO TOP OF... GC GENERAL CONTRACTOR TOB TOP OF BEAM GL GLASS TOO TOP OF CONCRETE; CURB GLAM GLUE -LAMINATED TOF TOP OF FLOOR; FOOTING; FRAME GR GRADE TOM TOP OF MASONRY GWB GYPSUM WALL BOARD TOPO TOPOGRAPHY GYP GYPSUM TOS TOP OF SLAB HB HOSE BIB TOW TOP OF WALL HC HOLLOW CORE IS TUBE STEEL TOO HIGH DENSITY OVERLAY TSTAT THERMOSTAT FOR HEADER TPH TOILET PAPER HOLDER HDWD HARDWOOD IYP TYPICAL HOW HARDWARE UNO UNLESS NOTED OTHERWASE HM HOLLOW METAL UC UNDER COUNTER HORIZ HORIZONTAL VB VINYL BASE HP HIGH POINT VEN VENEER HR HOUR VERT VERTICAL HT HEIGHT VEST VESTIBULE HVAC HEATING/VENTILATING/ VG VERTICAL GRAIN AIRCONDMONING VIF VERIFY IN FIELD HW HOT WATER VT VINYL TILE HWT HOT WATER TANK SYMBOLLEGEND 1. GRID LINE 2. ROOM REFERENCE XXX - ROOM NAME XXX ROOM NUMBER o 3. DOOR REFERENCE a REFERENCE DOOR NUMBER 4. WINDOW REFERENCE WXX REFERENCE WINDOW SCHEDULE 5. EXTERIOR ELEVATION 1XDRAWING NUMBER AX.XX - SHEET NUMBER 6. SECTION X DRAWING NUMBER AX.XX SHEET NUMBER 7. DETAIL REFERENCE X DRAWING NUMBER (SECTION) AX.XX SHEET NUMBER X DRAWING NUMBER B. DETAIL REFERENCE AX.XX SHEET NUMBER (PLAN) 9. ELEVATION REFERENCE �,a�_ ITEM LOCATION YK-XX" ELEVATION X DRAWING NUMBER SHEET NUMBER 10. INTERIOR ELEVATION X AX.XX X X 11. ASSEMBLY REFERENCE fO SEE SHEET AO.20 OAA ONLY MOST RECENT REVISION SHOWN CLOUDED. 12. REVISION REFERENCE FOR PREVIOUS REVISIONS REMAIN. DATE OF REVISIONS INDICATED AT RIGHT MARGINS. SYMBOLKEY WOOD BLOCKING SHIM CONCRETE FINISH WOOD � STEEL BATT INSULATION ALUMINUM RIGID INSULATION WOOD FRAMING (CONTINUOUS) CONCRETE MASONRY UNIT FIREBRICK IV� PLYWOOD /�/ EARTH i VENEER STONE GRAVEL W WEST W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WDW WINDOW WT WIDE FLANGE WF BM WIDE FLANGE BEAM WG WIRED GLASS WH WATER HEATER WL WATER LINE WILD WELDED WP WATERPROOF WPM WATERPROOF MEMBRANE WR WATER RESISTANT WSCT WAINSCOT WSG WIRE SAFETY GLASS Wf WEIGHT WiR WATER GENERAL NOTES 1. CODES: ALL WORK SHALL CONFORM TO THE WASHINGTON STATE BUILDING CODE AND ALL OTHER GOVERNING LAWS, CODES, ORDINANCES AND REGULATIONS. 2. DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED DIMENSIONS ONLY. NOTIFY ME ARCHITECT IMMEDIATELY IF ANY CONFLICTS EXIST. 3. ALL DIMENSIONS ARE TO FACE OF FRAMING AND CONCRETE WALLS UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO INITIATING THE WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 5. VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT. PROVIDE ALL BUCK -OUT, BLOCKING, BACKING, AND JACKS REQUIRED FOR INSTALLATION. 6. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED, 7. SERVICE WATER PIPES IN UNHEATED SPACES SHALL BE INSULATED. 8. PROVIDE FIRE -STOPPING AT ALL INTERSECTIONS BETWEEN CONCEALED WALL AND HORIZONTAL SPACES, SUCH AS SOFFIT OR CEILING, 9. PROVIDE DRAFT -STOPPING IN CONCEALED SOFFIT SPACES WHERE REQUIRED BY CODE. 1D. ALL INSULATION MATERIALS SHALL HAVE FLAME -SPREAD RATING NOT TO EXCEED 25 AND A SMOKE -DEVELOPED RATING NOT TO EXCEED 450. 11. CLEAR DEBRIS FROM ALL VENTILATION DRILL HOLES AND NOTCHES. 12. REMOVE ALL UPC STICKERS AND LABELS FROM PIPING, HANGERS ETC, UNLESS REWIRED BY CODE PRIOR TO INSTALLATION DESIGN BUILD/UNDER SEPARATE PERMIT ELECTRICAL ENGINEERING (NOTE: LIGHTING LOAD CALCULATIONS PER WS ENERGY CODE) FIRE ALARM SYSTEM MECHANICAL ENGINEERING PLUMBING ENGINEERING SPRINKLER SYSTEM NITOu' LANDLORD WESTFIELD, I.I.C. 2800 SOUTHCENTER MALL SEATTLE, WASHINGTON 98188 CONTACT: EMAY YEE T. 847-779-4832 M. 773-372-D565 emily.yee@um.com ARCHITECT GRAHAM BABA ARCHITECTS 1507 BELMONT AVE, SUITE 200 SEATTLE, WASHINGTON 98122 PHONE: 206-323-9932 CONTACT: MAKI SCHMIDT EMAIL• maki®grohembabo.com MECHANICAL ELEC/ PLUMBING TES ENGINEERING 25760 FIRST STREET CLEVELAND OHIO 44145 PHONE: 440 871-2410 CONTACT: DARREN S. JOHNSTON CONTACT: KATIE RUSSO PHONE: 206-818-0815 EMAIL: krussoWtesengineering.com EMAIL: djohnstm@harborengineers.com CONTRACTOR TBD BUILDING CODE INFORMATION APPLICABLE CODES: WASHINGTON STATE BUILDING CODE 2015 INTERNATIONAL BUILDING CODE WITH AMENDMENTS WASHINGTON STATE ENERGY CODE CODE AUTHORITY CITY OF TUKWILA EXISTING USE/OCCUPANCY: M RETAIL CHANGE OF USE/OCCUPANCY: B-RESTAURANT CONSTRUCTION TYPE: TYPE 2-B STORIES: 3-STORY TENANT SPACE: 1 STORY TENANT SPACE 1,609 SF REF. SHEET AO.02 FOR ADDITIONAL CODE INFORMATION DRAWING INDEX AO.01 GENERAL INFORMATION AO.02 CODE COMPLIANCE & EGRESS DIAGRAM AO.03 SCHEDULES & ASSEMBLY TYPES AO.04 TYPICAL FRAMING AND ASSEMBLY TYPES A1.01 SITE PLAN A2.01 DEMO PLAN AND FLOOR PLAN A4.01 STOREFRONT SECTION A5.01 STOREFRONT ELEVATIONS A5.02 ELEVATIONS A6.01 REFLECTED CEILING PLAN A8.01 CASEWORK DETAILS A&02 CASEWORK DETAILS S1 GENERAL STRUCTURAL NOTES AND ABBREVIATIONS S2 PARTIAL ROOF FRAMING PLAN AND PARTIAL MALL FRAMING PLAN S3 DETAILS M0.1 MECHANICAL LEGEND AND DETAILS MO.2 MECHANICAL SCHEDULES MO.3 MECHANICAL SPECIFICATIONS M1.0 MECHANICAL PLAN EO.1 ELECTRICAL LEGEND & DETAILS EO.2 ELECTRICAL SPECIFICATIONS EO.3 ONE LINE & PANEL SCHEDULES ELL LIGHTING PLAN E2.0 POWER PLAN PDA PLUMBING LEGEND, DETAILS, AND SCHEDULES PO.2 PLUMBING SPECIFICATIONS PI.0 DOMESTIC WATER PLAN P1.1 SANITARY PLAN P2.0 RISER DIAGRAM K-1 KITCHEN EQUIPMENT PLAN K-2 KITCHEN EQUIPMENT SCHEDULE Ii KITCHEN ELECTRICAL ROUGH -IN PLAN K-4 KITCHEN MECHANICAL ROUGH -IN PLAN K-5 KITCHEN WALL BACKING PLAN K-6 KITCHEN ELEVATIONS VICINITY MAP TENANT HOMEGROWN SUSTAINABLE SANDWCH SHOP S 120 LAKESIDE AVE, SUITE 310 SEATTLE, WASHINGTON 98122 PHONE: 206-491-9532 _ CONTACT: MATT HOFFMAN I EMAIL: matt.hoftmanAeathomegrown.com l ' 'i KITCHEN EQUIPMENT CMA RESTAURANT SUPPLY & DESIGN, INC. e; 12811 HE 126th Place, Kirkland, WA 98D34 , CONTACT JEFF VANIER ti PHONE 425-747-7223 EMAIL Jeffw&cmarestourantsuppiy.cam STRUCTURAL ENGINEER HARBOR CONSULTING ENGINEERS, INC. p 3316 FUHRMAN AVE EAST, SUITE 250 _ SEATTLE, WA 99102 " £V SO ,HGENTER NOT TO SCALE PROJECT SITE PROJECT DESCRIPTION INTERIOR, NON-STRUCTURAL TENANT IMPROVEMENT TO EXISTING RETAIL SPACE #532 AT SOUTHCENTER MALL PROJECT LOCATION: 841 SOUTHCENTER MALL TUKWILA, WA 9818B PARCEL NO.: 9202470010 ZONING: TUC -RC ZONING OVERLAY: N/A LOT AREA: 1,355,919 SF LEGAL DESCRIPTION: WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #00-032 REC #20101021000765) REVISIONS No C ue . a' be Made, TO the scope of work wnnoe. Pi �� ani, oval of ine Tukwila Building D,nsion_ NOTE Revisions will reamre a new plan submittal and may include additional plan review. F1 LM-P- P®=l�L rtrtR No. Plan review approval is subject to errors and ommums. Approval of construction documents aces oat authnoze The violation of any Wanted Coce or Ordinance Receipt of approved Field COpv and c twos 5 cknowledged: ay Date.. 69 -31-( 7 auuo°of Tukwi,a Hc nr�ision EBUILDING OR NCE D 11199-� ia ION RECEIVED CITY}O; TU-KWILA jU: ,j 2 ', 2019 PEPMIT CENTER a e } 4, �tr C a x ®� Thu u t507 mont Ave S It200 Sv.td., washing 99122 206.3239932 SEPARATE PERMIT REQUIREOFOR: JCCCjjj... Machanicml Elaciricd L /Plumbing Gas PipingofTukwila NG DIVISION City of Tukwila Approval Stamp: NOT FOR CONSTRUCTION BID SET MAY 10, 2019 j ,. _ ---------- Homegrown at Southcenter 841 Southcenter Mall Space#532 Seattle, WA 98188 Project No. 1906 City of Tukwila Project No. D19-0137 Date: May 10, 2019 Revision: Scale: AS NOTED Sheet contents: General Information Sheet: Aull fn Iq to () 10 57 W Z L.J O N v, 405 — TUKWILA PKWY PARKING /PARKING PARKING PARKING PARKING �. PARKING �k i 't h' ENTRY PARKING Y ENTRY ENTRY z FTI s . S'�s C .� �. . z sz t ,.� r ;�� k'r t `` Vic;., 4 � '.. r .x "•;�,,Y t r ` t : r I � s wT �zt`=� k � '``,,,�,� �u;,,z' '1'T;� x�;,a�1Ts"'>��.,``rZ,"�"sT%�'�`��<i '+��a"� �`eY`� °� 'r. x ✓,. ~��' ``� .r r. r ENT ENTRY ENTRY PARKING' PARKING' PARKING PARKING i— � SITE PLAN I•:%1=a31 SITE INFORMATION PROJECT LOCATION: 841 SOUTHCENTER MALL TUKWILA, WA 98188 PARCEL NO.: 9202470010 ZONING: TUC —RC ZONING OVERLAY: N/A LOT AREA: 1,355,919 $F BUILDING AREA: 553,580 SF INTERIOR WORK AREA: 1,609 SF LEGAL DESCRIPTION: WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP JL10-032 REC #20101021000765) REVIEWED FOR CODE COMPLIANCE APPROVED JUL 19 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA E;J-' 211212 PERN111" CENTER z: �z � y ®© Y z � Y m a 1507 Belmont Ave, $uit 200 SeattIe,Washin9ton 91122 206=2 932 MIR City of Tukwila Approval Stamp: NOT FOR CONSTRUCTION BID SEAT MAY 10, 2019 Homegrown at Southcenter 841 Southcenter Mail Space#532 Seattle, WA 98188 Project No. 1906 City of Tukwila Project No. D19-0137 Data,. May 10, 2019 Revision: Scale: AS NOTED Sheet contents: Site Plan Sheet: A1.01 4IN111111, U111t, ABBREVIATIONS(All ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ONDRAWINGS) HVAC SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS) A AMP, AMPERE ID NSIDE DIAMETER ABV ABOVE E INVERT ELEVATION A/C AIR CONDITIONER, AIR CONDITIONING, IN INCH, INCHES ABOVECEILING IN WC INCHES OFWATERCOLUMN ACC AIR COOLED CHILLER DIFFUSER SUPPLY AIR DIFFUSER - SHADING INDICATES INDIC TWAY KVA KILOVOLT -AMPS ACCU AIR COOLED CONDENSING UNIT PATTERN.AIR ND SHOWN ADJ ADJUSTABLE KW KILOWATTS OR AFC AFF ABOVE FINISHED CEILING ABOVE FINISHED FLOOR KWH KILOWATT-HOUR z RETURN OR EXHAUSTAIR GRILLE L INTERNALLY LINED AEG ABOVE FINISHED GRADE AL ACOUSTIC LINING LAT LEAVING AIR TEMPERATURE ANSI AMERICAN NATL STANDARDS INSTITUTE LBS,S LDS POUNDS LEAVING DRY BULB ROUND DUCTWORK DIAMETER IN INCHES APD ARCH AIR PRESSURE DROP ARCHITECT, ARCHITECTURAL LP LOWPRESSURE ARI AIR CONDITIONING& REFRIG INSTITUTE LRA LOCKED ROTOR AMPS 20I12 RECTANGULAR DUCTWORK SIZE IN INCHES, ASHRAE AMERICAN SOCIETY OF HEATING, LTG LIGHTING FIRST NUMBER IS SIDE SHOWN REFRIGERATION&AC ENGINEERS LWB LEAVING WET BULB ASME AMERICAN SOCIETY OF MECHANICAL ENGRS LWT LEAVING WATER TEMPERATURE ABBY ASSEMBLY XJUXXL INTERNALLY LINED DUCT MAX MAXIMUM MAXIMU1000 M ASTM AMERICAN SOCIETY OF TESTING & MAILS AIN AUXILIARY MAX PER HOUR AWS AMERICAN WELDINGRE MC MCA MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY SUPPLY OR OUTSIDE AIR DUCT AWS SE AMERICAN WATER MCC MOTOR CONTROL CENTER AWWA WORKS AMERICAN WATER WORKS ASSOC.A MD MECH MOTORIZED DAMPER MECHANICAL RETURN, RELIEF OR EXHAUST AIR DUCT BF BELOW FLOOR RAS BUILDING AUTOMATION SYSTEM MFR MH MANUFACTURER MANHOLE, METAL HALIDE DIFFUSERIGRILLE LABEL: BUD BFW BACKDRAFT DAMPER BOILER FEED WATER MIN MINIMUM A B A-TYPEIDESIGNATION BLDG BUILDING MOCP MAXIMUM OVER CURRENT PROTECTION B- NECK SIZE (INCHES) BMS BUILDING MANAGEMENT SYSTEM MITD MOUNTED C C-AIRFLOW(CFM) BOB BOTTOM OF DUCT RUA MAKE-UPAIR BOP BOTTOM OF PIPE NIA NOT APPLICABLE SO BOTTOM OF STRUCTURE N.C. NOT CLOSED 90 DEGREE DUCTWORKELBOWW TURNING VANES BTU BRITISH THERMAL UNIT NO NEC NOISECRITERIA NATIONAL ELECTRICAL CODE WWW ,�j CA COMBUSTIONAIR CC CONCRETE NEN1A NATIONAL ELECTRICAIMFR'SASSOC. �r TURNING VANES CFH CUBIC FEET PER HOUR NFPA NATIONAL FIRE PROTECTION ASSOC. GEM CUBIC FEET PERMINUTE NIC NOTINCONTRACT RADIUSDUCTWORKELBOW- CHWRICHWSCHILLEDWATERRETURNISUPPLY N.O. NORMALLY OPEN ROUND OR RECTANGULAR CIRO CIRCULATING NTS NOT TOSCALE CKT C. CIRCUIT CENTERLINE 0!H OVERHEAD CEILING OA OUTSIDE AIR(VENTILATION AIR) RECTANGULAR DUCTWORK BRANCH TAKE -OFF CO GO CLEANOUT OBD OPPOSED BLADE DAMPER WITH DEGREE DEGREE BRANCH INLET CONN C,CONNECTION OC 00 ON CENTER OVERFLOW DRAINAGE, OUTSIDE DIAMETER COP COL CTE COTPLUG LEANO COLUMNLUMN U CONNECT TOEXISTINGLDWTE OPNG ORD OPENING OUTSIDE WROOFD AIN r HIGH EFFIECENY'BUCKLEY" TAP WITH DAMPER CW DOMESTIC COLD WATER OS&Y YOKE OUTSIDE STEM ANDYOKE rWS T!-• CONDENSING WATER RETURN/SUPPLY DEGREESCELSIUS OSHA OCCUPATIONAL SAFETY&HEALTH ADMIN. iD I= DUCTWORK SIZE TRANSITION SUPPLY OR OUTSIDE AIR DUCT UP D DEPTH PB PUSHBUTTON PD PRESSURE DROP DB DRY BULB • • • • PHASE dS DECIBEL PIV POST INDICATORVALVE DDC DIRECT DIGITAL CONTROL PLBG PLUMBING SUPPLY OR OUTSIDE AIR DUCT DOWN DEG DEGREES PSI POUNDS PER SQUARE INCH -•••••DIAMETER PRV PRESSURE RELIEFVALVE RETURN OR EXHAUST AIR DUCT UP DIM DISC DN DIMENSION DISCONNECT DOWN RETURN OR EXHAUST AIR DUCT DOWN RA RETURN AIR RCP REFLECTED CEILING PLAN DOM IDS DOMESTIC DOWNSPOUT RD RECIRC ROOFDRAIN RECIRCULATE DWG DRAWING REINF REINFORCING, REINFORCED �� IN -LINE 90 DEGREE RISE IN DUCT DX DIRECT EXPANSION REL REV REV RELOCATED REQUIRED REVISION, REVISE J� 7 I W I_( IN -LINE 90 DEGREE DROP IN DUCT EA EACH EAT ENTERING AIR TEMPERATURE REX REMOVE EXISTING EC ELECTRICAL CONTRACTOR RH RELATIVE HUMIDITY RISE INCLINED RISE IN DUCT EDB ENTERING DRY BULB RHO REFRIGERANT HOT GAS ELEV ELEVATION RL REFRGERANT LIQUID ELEC ELECTRICAL RLA RUNNINGLOADAMPS ® POINT OF CONNECTION - NEW TO EXISTING ENCL ENCLOSURE RPM REVOLUTIONS PER MINUTE EQUIP EQUIPMENT RR REMOVE AND RELOCATE ESP EXTERNAL STATIC PRESSURE RS REFRIGERANT SUCTION MANUAL VOLUME DAMPER ETR EXISTING TO REMAIN RVE RAINWATER CONDUCTOR FINS EWT ENTERINGWET BULB ENTER NGWATER TEMPERATURE M MOTORIZED DAMPER SA SUPPLYAIR EXIT EXHAUST SAN SO SANITARY SMOKE DETECTORSTORM DRAIN F EX EXISTING SECT SF , SECTION SQUARE FEET, SQUARE FOOT FIRE DAMPER FA FIREALARM FACE FIRE ALARM CONTROL PANEL BHT SM SHEET SHEETMETAL Q THERMOSTAT FCO FD FLOOR CLEANOUT FIREDAMPER SMACNA SHEET METAL & AC CONT NAT. ASSOC. FF FINISHEDFLOOR SP STATIC PRESSURE O HUMIDISTAT FLA FULL LOAD AMPS SPEC SPECIFICATION FLEX FLEXIBLE SQ ST SQUARE STORM WATER Q SENSOR FP FIRE PROTECTION STD STANDARD FPM FT FEET PER MINUTE FOOT, FEET SURF SURFACE © CARBON DIOXIDE SENSOR FW FILTEREDWATER BUSE SUSPEND TDH TE TOTAL DYNAMIC HEAD TENANT EXHAUST (TOILET) •••• DEGREES FAHRENHEIT SD DUCT SMOKE DETECTOR G GAS GA GAUGE THIRD TP THROUGH TOTAL PRESSURE �.. DRAWING NOTE REFERENCE GAL GALV GALLON GALVANIZED TSP TOTAL STATIC PRESSURE �:l GC GENERAL CONTRACTOR TSTAT THERMOSTAT ROUND GFL GFIC GROUND FAULT INTERRUPTER TWRITWS TOWER WATER RETURNISUPPLY GET)GALLONS PER DAY TYP TYPICAL .e. OVAL OR FLAT OVAL THE UNDERFLOOR GPH GALLONS PER HOUR GPM GALLONS PER MINUTE UIG UNDERGROUND UC UNDERCUT DOOR 3I4'FOR AIRFLOW GRD GROUND UtS UNDERSLAB —` GW GREASE WASTE UL LION UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED H HEIGHT HD HEAD, HUB DRAIN V VOLT, VENT HHWRIHHWS HEATING HOT WATER RETURN/SUPPLY VA VOLT-AMPERE, VALVE HOA HAND -OFF -AUTOMATIC VAC VACUUM HP HORSEPOWER, HEAT PUMP VAV VARIABLE AIR VOLUME HSTAT HUMIDISTAT VD VOLUME DAMPER HTG HTR HEATING HEATER VTR VENT THROUGH ROOF IN WATT, WIDTH HVAC HEATING, VENTILATING &AIC HW DOMESTIC HOTWATER W WITH HWR DOMESTC RECIRCULATED HOT WATER WO WITHOUT HYD HYDRANT N,8 WET BULB HZ HERTZ WC WATER COLUMN RECTANGULAR DUCMORK VARIES MINIMUM TAKE OFf AREA1.25 TIMES BRANCH DUCT AREA RECTANGULAR TO ROUND ,BUCKLEY FITTING' RECTANGULAR ROUND DUCTWORK DUCTWORK 4" BRANCH DUCT HEIGHT DIMENSION 2°LESS THAN MAIN DUCT HEIGHT DIMENSION RECTANGULAR TO RECTANGULAR LOWLOSS TEE FITNG OR SADDLE 1 DUCT BRANCH TAKE -OFF DETAIL M0.1 SCALE: NONE PRE -MANUFACTURED AIR COOLED PIPE CURB CONDENSING UNIT COORDINATE LOCATION OF ROOF RAILS FOR CONDENSING UNIT WITH ROOF STRUCTURAL ENGINEER OUTSIDE AIR DUCT SEE STRUCTURAL DRAWINGS FOR WITH FLEX CONNECTION CONNECTION DETAILS AND FURTHER TO MIXING BOX---__OA 1 INFORMATION RETURN AIR DUCT 1 VIBRATION ISOLATOR (TYPICAL) WITH FLEXCONNECTION 1 CONDENSATE DRAIN LINE FROM UNIT W FLEX SUPPLYAIR DUCT WITH FLEX CONNECTIONS TO CONNECTION TO UNIT, REFER CONDENSATEPUMP ANGLE SUPPORT FOR TO PLANS FOR CONTINUATION ANDSQES AHU AND DRAIN PAN ELECTRONIC WATER SENSOR WIRED TO 3" DEEP WATERTIGHT DRAIN PAN, PAN SHUTDOWN UNIT WHEN CONDENSATE WATER SHALL BE 3' LARGER THAN UNIT ON ALL SIDES ENTERS DRAIN PAN. LOCATE SENSOR AT LOW POINT IN PAN. DETAIL NOTES 1. MC SHALL LOCATE AHU TO MAINTAIN A MINMUM 24'SERVICE CLEARANCE IN FRONT OF UNIT FOR MOTOR ACCESS PANEL FROM ANY EXISTING BUILDING STRUCTURE OR PIPING EXTENDING DOWN TO CEILING PER MANUFACTURERS RECOMMENDATIONS. MC SHALL COORDINATE WITH OTHER TRADES TO KEEP THIS SERVICE AREA CLEAR OF ANY NEW PIPING OR CONDUIT. 3 SPLIT SYSTEM UNIT DETAIL MDA SCALE: NONE ROOF MOUNTED EXHAUST EXTEND DUCTWORK OVER FAN WITH BIRDSCREEN TOP OF CURB, SECURE j a SECURE FAN TO WOOD NAILING STRIP DUCTWORKTOCURB HAILER 1 $_ SCREWS 1?O.C, MIN TWO PER SIDE PREFABRICATED, INSULATED ROOF CURB, CURB FURNISHED BY HVAC CONTRACTOR --- - ••-- DUCT ROOF INSULATION INSTALLATION OF CURB SHALL 'A. BE IN COMPLIANCE WTH ROOF r MANUFACTURER'S REQUIREMENTS 15TW3Imm zffZ@ilEN � MAX. 12' TO BRANCH CONNECTION VOLUME DAMPER IF INDICATED ON PLAN 1-IT THICK FIBERGLASS SUPPLYAIR DIFFUSER GALVANIZED SHEET METAL DUCT DETAIL NOTES 1. DO NOT LOCATE DAMPERS ABOVE DRYWALUIINACCESSIBLE CEILING LOCATIONS. 2 CEILING DIFFUSER MOUNTING DETAIL M0.1 SCALE: NONE W R=W FULL RADIUS ELBOW DOUBLE THICKNESS TURNINGVANES RECTANGULAR ELBOW METAL OR VINYL ADJUSTABLE STRAP CLAMP (TYP 2 PLACES) INSULATED FLEXIBLE CONNECTION N VERTICAL ONLY (MAX. 5) LAY -IN CEILING LOW VELOCITY ELBOWS AIR FLOW � \ AIR FLOW TRANSITION LENGTH TO BE 1&"MIN TRANSITION LENGTH TO BE 18" MIN DIVERGING FLOW CONTRACTING FLOW RECTANGULAR TO RECTANGULAR TRANSITIONS B W R W W R w w ....�.......................... FULL RADIUS WHERE POSSIBLE (R = WJ 4 LOW VELOCITY TRANSITIONS AND OFFSETS M0.1 I SCALE: NONE LANDLORD REQUIREMENTS: 1. TENANTS GENERAL CONTRACTOR, AT TENANTS EXPENSE, SHALL BE REQUIRED TO FURNISH TEMPORARY WEATHERPROOFING FOR ALL ROOF PENETRATIONS, UNTIL LANDLORD'S ROOFING CONTRACTOR HAS MADE FINAL WEATHERPROOFING PATCHES, AT TENANT'S EXPENSE. TENANTS STORE SPACE NUMBER SHALL BE PERMANENTLY STENCILED ON ONE SIDE OF ANY ROOF -MOUNTED HVAC UNIT, WIN THE MINIMUM THREE-INCH (31 HIGH LETTERS. 2. ALL ROOF AND SLAB PENETRATIONS MADE BY TENANTS GENERAL CONTRACTOR SHALL CONFORM TO LANDLORD'S STANDARD CRITERIA AND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. WEATHERPROOFING OF ANY —..: ROOF PENETRATIONS REQUIRED BY TENANT SHALL BE PERFORMED BY LANDLORD'S AUTHORIZED ROOFING CONTRACTOR. TENANTS GENERAL CONTRACTOR SHALL PAY ANGLE FRAMING PER STRUCTURAL ANY SUCH COSTS, THEREFORE, DIRECTLY TO SUCH ROOFING CONTRACTOR UPON THEIR REQUIREMENTS DEMAND. ANY FAILURE TOFOLLOWTHISPROCEDURE,ANDANYDANIAGESRESUITING REVIEVVEDFOR THEREFROM, SHALL BEAT THE TENANTS SOLE COST AND EXPENSE. ODE COMPLIANCE OPENING BY GENERAL CONTRACTOR APPROVED COORDINATE FRAMING 3. INSTALLALLDUCTWORKASTIGHT TOSTRUCTUREASPOSSIBLE. ROUTE TOAVOIDLIGHT AND OPENING SIZE WITH FIXTURES. MAINTAIN DUCT HEIGHTS TOACCOMODATE CEILING HEIGHTS, REFER TO JUL192019 HVAC CONTRACTOR REFLECTIVE CEILING PLAN. HVAC CONTRACTOR DETAIL NOTES RVAC CONTRACTOR TO COORDINATE INSTALLATION WITH LANDLORD APPROVED ROOFING CONTRACTOR FOR PROPER SEQUENCE TO PERMIT FLASHING AND COUNTERFLASHING INSTALLATION. 5 ROOF MOUNTED EXHAUST FAN DETAIL M0.1 SCALE: NONE 4. VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE City ofT- Wfla WHEN HANGING/ SUPPORTING HVAC EQUIPMENT, DUCTWORK, PIPING, WATER HEATERS, ILDING DIVISION TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANTS ARCHITECT. ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL NOT BE FASTENED TO BAR JOISTS OR BEAMS. RECEIVED CITY OF TUKWILA 5. GC MUST SCAN SLAB PRIOR TO DRILLINGICUTTINGICHIPPING, AND ALL OPENINGS MUST RI k 2513 S.i' P'2 BE REVIEWEDIAPPROVED BY BLDG STRUCTURAL ENGINEER. PERMIT CENTER AIR HANDLING UNIT SCHEDULE SUPPLY FAN DATA DX COOLING COOLING COIL DATA ELECTRIC HEATING DATA UNIT CHARACTERISTICS TAG SERVICE MFR MODEL No. NOMINAL MIN OA NOTES/ACCESSORIES AIRFLOW ESP MOTOR FAN » » •-••-••••56NSIBLE TOTAL COOLING EATILAT INPUT OUTPUT HEATING VOLTAGE OPERATING TONS (CFM) (CFM) (IN WC) (HP) (RPM) •••»•» »••»» (MBH) (MBH) RONS STAGES »•»» (KIM (MBH) STAGES (V-¢-Hz) UNIT FLA UNIT MCA UNITMOCP WEIGHT (LBS) AHU4 WHOLESTORE CARRIER 40RUAAOB 7.5 640 3400 0.75 1.74 891 75.9164.0 65,4154.4 74.8 ST3 4 2 61.1/78.7 25.0 64.15 2 20.B. 59.2 74D &0.0 1 404 TS NOTESIACCESSORIES 1. REFRIGERANT -R410A 2. MIXING BOXWITH IOD% DRYBULB ECONOMIZER 3. MERV7 FILTERS 4. UNIT MOUNTED DISCONNECT 5. BELT DRIVE 6. SINGLEZONEVAV 7. PROGRAMMABLE AUTO CHANGE OVER THERMOSTAT NTH REMOTE TEMPERATURE SENSOR B. VIBRATION ISOLATORS CONDENSING UNIT SCHEDULE COMPRESSOR DATA ELECTRICAL DATA OPERATING TAG SERVICE LOCATION MFR MODEL No. EER NOMINAL WEIGHT NOTESIACCESSORIES QUANTITY RLA „, „, lRA ,,, •,„ „, VOLTAGE (V4_Hz) MCA MOCP TONS (LBS) CU-1 AHU-i ROOF ABOVE CARRIER 38AUZDGB 11.2 7.5 2 24 186 2W3a 33.0 50.0 391 1-15 NOTESiACCESSORIES 1. UNIT CAPACITY SHALL BE BASED ON AHRI CONDITIONS 2. .............................. I.................. 3. R410A REFRIGERANT 4. SCROLL COMPRESSOR 5. HIGH AND LOW PRESSURE SWITCHES ON REFRIGERANT SYSTEM 6. SHORT CYCLE PROTECTION 7. FILTER -DRYER ON REFRIGERANT SYSTEM 8, SINGLE CIRCUIT COMPRESSORS 9. LIQUID LINE SOLENOID VALVE 10. COATEDCOILS 11. HAILGUARD 12. VIBRATION ISOLATORS - PAD 13. 1 YEAR PARTS & LABOR WARRANTY 14. 5 YEAR EXTENDED COMPRESSOR PARTS & LABOR WARRANTY 15. APPROVED ALTERNATES: TRANE, LENNOX, AND YORKLOHNSON CONTROLS OUTSIDE AIR SCHEDULE ZONE DATA SYSTEM DATA FLOOR REQUIRED REQUIRED BREATHING ZONE ZONEAIR REQUIRED SUPPLY SYSTEM REQUIRED DELIVERED ZONENAME AREA OUTSIDE AIR OCCUPANCY OUTSIDEAIR OUTSIDE AIR DISTRIBUTION OUTSIDE AIR AIR OUTDOOR AIR 78YSTE.-EVENTILATION OUTSIDE AIR OUTSIDEAIR (SE) (CFMISF) (CFM/PERSON) (CFM) EFFECTIVENESS (CFM) (CFM) FRACTIONEFFICIENCY (CFM) (CFM) BACK OF HOUSE 282 0.12 4 0 34 0.8 43 60D (1072 AHU-i 0.790 S38 640 DINING 686 0.18 30 7.5 348 S8 435 1200 0.363 KITCHEN 427 0.18 6 7.5 122 0.8 153 1600 0.096 NOTES 1, SPACE OUTSIDE AIR REQUIREMENTS BASED ON IMC 2015 EXHAUST FAN SCHEDULE AIRFLOW ESP MOTOR FAN VOLTAGE OPERATING TAG SERVICE MFR MODEL No. (CFM) (IN WC) (HP/KN DRIVE (RPM) SONES NOHz) WEIGHT NOTESIACCESSORIES (LBS) EF-1 KITCHEN GREENHECK G-O80-VG 300 0.5 0.07 DIRECT 1664 8.2 120-1-60 41 1.8 NOTESIACCESSORIES 1. AMCA SEAL & U.L. LISTED 2. DISCONNECT SWITCH - NEMA 1- FACTORY MOUNTED & WIRED 3. BACKDRAFT DAMPER- GRAVITY 4.14° ROOF CURB 5. BIRD SCREEN -GALVANIZED 6, FAN SPEED CONTROLLER- FACTORY MOUNTED & WIRED T FAN CONTROLLED BY TIME CLOCK 8. APPROVED ALTERNATES: COOK HARTLEL, AND COOL AIR AIR DISTRIBUTION SCHEDULE TAG SERVICE MOUNTING MFR MODEL No. ODULEI DIFFUSER MUSER SIZE FRAMEIBORDER DAMPER NOTESIACESSORIES St SUPPLY CEILING TITUS HELIOS 24724° LAY IN - 1,2,4 82 SUPPLY CEILING TITUS OMNI 24X24" LAY IN D-75 iJ Rt RETURN CEILING TITUS 5OF 24X24" LAY IN 1 R2 RETURN CEILING TITUS I 50F 24°X24° LAPIN - 1,3 Et EXHAUST CEILING TITUS SOF 17X12" I LAYIN I - 1,3 NOTESIACCESSORIES 1. FINISH - WHITE POWDER COAT 2. SECTORIZING BAFFLE (SE) AS REQUIRED BY DIRECTIONAL ARROWS ON PLAN, OTHERWISE FOUR (4) WAY BLOW 3. STEEL SURFACE MOUNT ADAPTER FRAME 4. PROVIDE WITH ONE COMMON WALL SENSOR AND ONE COMMON POSTMASTER FOR WIRELESS CONTROL REVIEWED FOR CODE COMPLIANCE APPROVED JUL 19 2019 City of TukWyla BUILDING DIVISION RECEIVED CITY OF T UKWILA 2 )I 2312 PERa-11T CEN'E s L F. MECHANICAL SPECIFICATIONS Air System Sizing Summary for AHU-1 Project Name: WA.SOUTHCENTER.HOMEGROWN.KIRKLAND.WA 03l22I20t9 Pre aced b :TES En ineedn 10257AM Air System Information Air System Name AHU-1 Equipment CFdss ___._--_-._._. SPILT AHU Air System Type Sizing Calculation Informaticn Calculation Months __.Jan to Dec Sizing Data --_-..___User-Modified Central Cooling Coil Sizing Data Total cal load ___ _8.3 Tons Total call load 99.1 MBH Sensibkecoil load_ ... _75.5 MBH Coil CFM at Jul 1500-._...____.__.___3400 CFM Max block CFM ________...___.____.__.__ 3400 CFM Sum of cook zone CFM ___._._._......_._.__._..._3400 CFM Beneath . heat ratio---`_-_'-'---. 0.762 f YTon _____._ _ - -_. 168.9 BTUl Water flow @ 10.0 -F rtse.._________-...__ 71A WA Central Heating Coil Sizing Data Maxco111oad.._._.._______.__._-__._.____.._..26.9 MBH CCIICFMat Des Hlg_._.___._._..._.____.__...__._3400 CFM Macool CFM __...__3400 CFM Water flow Q 20.0`F dmp_ ____-._WA Supply Fan Sizing Data Actual max CFM_.__.....__-___.__._.._._____3400 CFM Standard CFM _________.-___.__-. 3345 CFM Actuamax CFMAV_- _.__2.44 CFMJft' Outdoor Ventilation Air Data Design airOow CFM _...___-_._ 640 CFM _..... _._...__.__..___0.46 CFM1W Number ofzones _____t W Location ____.__ Seattle LAP, Washington Zone CFM Sizing__._.._.._ Sam of space afdiow miss Space CFM Sizing _ Individual peak space loads Load occurs at _-._Jul 1500 CA UPI WB ___ _85.0165.0 'F Entering DS1DOB.._.._-.__ _._ -76.9164.0 'F Leaving US WB_ _._..___ 55.010.9 -F Coil ADP..._._._.._._..__...__.__.._.__._.._ ................... 52.6 'F Bypass Factor ___.._._____-._._._.:....._._._._0.100 Resulting RH_..-_...___._.__._..-_58 % Design supply temp. ______._-.__-55.0 Zone T-stat Check 'F _.__.0 oft OK Max zone temperature deviation -. 0.2 •F Load mans at .... ..... _..__..... __.._._.__._._._...- Des Htg BTUl_._____-________...._------ ._19.3 'F Fan motor BHP __._____._____....__...___-_ rife Fan motor kW._ ---- ..._._....._..___._..._.___._.___2.68 kW CFMlperson _...._.._.__.___.t6.00 CFWp.n- HmAYAnaysis Progremv5.00 Page 1 of 3 Zone Sizing Summary for AHU-1 Project Name: WASOUTHCE-11.1lOMEGROWN.MRKLAND.WA 03/Y1J2019 Prepared by, TES Engineering1D:57AM Air System Information Air System Name..-_______._..______ AHU-i Equipment Claso.- .......... SPILT AHU Air System Type __. -------------- .._..____._SZCAV Sizing Calculation Information Calculaban Months _Jan to Dee Sizing Data __._ .___ User -Modified Zone Terminal Sizing Data Number azones___.._.___.___ _________... i Floor Area..__.._..._.._.____..___._._..._..._.__.........1395.iN Location_.____ Seattle Up, Washington Zone CFM Sizing_. Sum of space airflow rates Space CFM Sizing _-..Individual peak space loads Reheat Zone Zone Design Minimum Reheat Coil Htg Unit Htg Unit Mixing Supply Supply Coll Water Coil Water Box Fan Zone Name Atdlow CFM AIM- CFM Zone CFWW Load MBH Was 2O.0'F Lead MBH gpm 2O.0'F Almow CFM Ron 1 34001 34001 2.441 1 0.0 0 Zone Peak Sensible Loads Zone Zone e Zot-me Cooling Time of Heating Floor Sensible Peak Sensible Load Ara Zone (Ma" Coolin Load g MBN t ) Zone 1 59.9 Jun 1300 4.3 395.0 Space Loads and Alrnows Houdy Analysis Program v5.00 Page 2 of I. GENERAL PROVISIONS A. GENERAL CONDITIONS, CODES & STANDARDS 1. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) AND ANY OF THE OWNER'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. 2. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS,STORAGE, ADJUSTMENTS, CLEANING, ETC. 3. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE OWNER REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. 4. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED MATH THE WORK THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. B. SCOPE OF WORK i. THIS CONTRACT SHALL INCLUDE THE FURNISHING,INSTALLING, CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS A PART OF THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE OWNER A COMPLETE, CODE APPROVED AND OPERATIONAL MECHANICAL SYSTEM. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES WORKSCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS ANDAVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE WORKISCOMMENCED. 3. CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND MECHANICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER. 5. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF HVAC WORK. ALLCORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS, AND WALLS SHALL BE FIRESTOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS, AND WALLS PENETRATED. THIS CONTRACTOR IS RESPONSIBLE TO COORDINATE OPENINGS IN WALLS AND FLOORS WITH THE GENERAL TRADES CONTRACTOR. THE FINAL LOCATIONS AND SIZES OF ALL DUCT, PIPE AND LOUVER OPENINGS SHALL BE PROVIDED BY THIS CONTRACTOR. 6. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND MISCELLANEOUS EXPENSES REQUIRED FOR ALL REQUIRED MECHANICAL DEMOLITION OF THE EXISTING AREAS BEING RENOVATED. a. THE DEMOLITION SHALL CONSIST OF THE COMPLETE REMOVAL(PROPERLY DISPOSED OFF SITE UNLESS OTHERWISE NOTED) OF ALL MECHANICAL EQUIPMENT, PIPING, DUCTWORK MATERIALS, ETC. NOT REQUIRED IN THE FINAL DESIGN AND INSTALLATION OF THE MECHANICAL HVAC SYSTEMS FOR THE NEW RENOVATED AREAS. It, ALL UNUSED SERVICES SHALL BE REMOVED BACK TO THEIR RESPECTIVE MAIN AND CAPPED OR IF THE MAIN IS NOT REQUIRED, THE MAIN SHALL BE REMOVED IN ITS ENTIRETY. c. COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS AND THE ARCHITECT AND THE OWNER'S GENERAL REQUIREMENTS. d. EQUIPMENT DESIGNATED BY THE OWNER TO BE SALVAGED SHALL BE PROTECTED AND DELIVERED TOTHE OWNER. e. DEMOLITION SHALL NOT AFFECT THE OPERATION OF SYSTEMS THAT ARE TO REMAJN IN OPERATION.ITEMS TO REMAIN THAT MAY BE DAMAGED BYTHE CONTRACTOR SHALL BE REPLACED AND/OR REPAIRED AT THE CONTRACTORS EXPENSE. tTHIS CONTRCATOR MUST COORDINATE HIS WORK WITH OTHER TRADES OR OWNER THAT MAY BE DOING DEMOLITION. g. ANY ASBESTOS REMOVAL SHALL BE THE RESPOSIBILHY OF THE OWNER FOR REMOVAL AND IS NOT A PART OF THIS CONTRACT. 7. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BYTHE ENGINEER AND OWNER. WHEREAN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. C.D000MENTS i. THE DRAWINGS ARE DIAGRAMMATIC, ALL WORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE OWNER. 2. ANY INCIDENTAL ITEMS OR LABOR,ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL BE REFERRED TO THE OWNER FOR REVIEWAND FINAL DECISION PRIOR TO THE BID DUE DATE. 5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANYONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL AND MUST BE SUBMITTED AS SPECIFIED IN THE ARCHITECTURAL DOCUMENTS. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. D. COORDINATION 1. CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TOAVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE, II. INSULATION A.GENERAL i. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDATIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. 2. CLEAN AND DRY SURFACES PRIOR TO INSULATING. 3, EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR PENETRATIONS. 4. INSULATION JACKET AND FITTING COVER MUST BE PLENUM RATED. 5. IT IS ESSENTIAL THATTHE INTEGRITY OF THE VAPOR -BARRIER BE MAINTAINED. SEALALL PENETRATIONS OF THE VAPOR BARRIER BY STAPLES, HANGERS OR WHERE OTHERWISE DAMAGED. 6. MAINTAIN ACCESS TO BALANCING DAMPERS AND VALVES. 7. INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE. B. HVAC PIPING 12, WATER HEATER FLUE AND FITTINGS SHALL BE METALBESTOS MODEL DF, COMMERCIAL/ INDUSTRIAL TYPE'B•GASVENT. a.............................................^............. ............................ U.L. STANDARD 103. It. DOUBLE WALL CONSTRUCTION WITH AN OUTER JACKET OF ALUMINIZED COATED STEEL AND AN INNER LINER OF TYPE 430 STAINLESS STEEL SEPARATED BY 10 AIR SPACE. a. C. CONTRACTOR SHALL INSTALL TOPS A MINIMUM OF T-T ABOVE ROOF OR HIGH ER IF REQUIRED BY CODE. CONTRACTOR TO PROVIDE ROOF FLASHING CONE AND MISCELLANEOUS EQUIPMENT OR COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION. 13. OUTSIDE AIR INTAKE a. SEE SCHEDULE ON DRAWINGS 14. GRAVITY BACKDRAFT DAMPERS a. SEE SCHEDULE ON DRAWINGS I& CONTROL DAMPERS a. SEE SCHEDULE ON DRAWINGS 1E GRILLES, REGISTERS AND DIFFUSERS a. SEE SCHEDULE ON DRAWINGS 1. PIPING SHALL BE INSULATED WITH FIBERGLASS PIPING INSULATION WITH AN ALL SERVICE JACKET AND IV. HVAC EQUIPMENT SELF SEALING LAP (ASYSSL). a. INTERIOR APPLICATION A GENERAL (1)CONDENSATE WATER PIPING -112INCH THICK 2. REFRIGERATION PIPING SUCTION PIPE SHALL BE INSULATED WITH 112 INCH CLOSED CELL INSULATION 1. INSTALLATION OFALL EQUIPMENT SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION AS MANUFACTURED BYARMAFLEX OR EQUAL. COAT ALL EXTERIOR INSULATION WITH 2 COATS OF U.V. INFORMATION AND INSTRUCTIONS, REQUIREMENTS AND ANYADDITIONAL GUIDELINES. CONTRACTOR STABILIZED PAINT SPECIFICALLY DESIGNED FOR THE CLOSED CELL INSULATION. SHALL PROVIDE ALLADDITIONAL REQUIREDACCESSORIES REQUIRED TO COMPLETE THE 3. EXTERIOR PIPING FIBERGLASS PIPING INSULATION WILL BE COMPLETELY COVERED WITH INSTALLATIONS. •• ........................................... • • • • ............. ••••••••••••• ... •••••••••••• .............. ^ •2 • •HVA0 EWPMENTeRAU.•BE'STARTE•D UP BYA FAQTQRYTRrAINEDAND AUTHOR42ED SERVICE WIRE. TRANSVERSE JOINTS SHALL BE KEPT TOA MINIMUM. LONGITUDINAL JOINTS SHALL BE MADE ON TECHNICIAN. THE BOTTOM OF THE PIPNG. INSTALLATION SHALL BE COMPLETELYWATER TIGHT. 3. ALL FACTORY STARTUP FORMS SHALL BE COMPLETED AND TURNED OVER TO THE OWNER WITH ALL COMPLETED WARRANTY CARDS PRIOR TO FINAL APPROVAL. C. RVAC DUCTWORK B. AIR COOLED CONDENSING UNITS 1. INTERNALLY INSULATE WITH i INCH THICK,1-112# DENSITYACOUSTICAL INSULATION (AIR SIDE BLACK COATED TO MEET NFPA) ALL DUCTWORK NOTED AS REQUIRING SUCH. INTERNAL INSULATION SHALL BE i. SEE DRAWINGS FOR INDIVIDUAL UNIT PERFORMANCE REQUIREMENTS. INSTALLED PER THE REQUIREMENTS OF THE SMACNAGUIDE ANDTHE MANUFACTURER'S 2. FURNISH AND INSTALL INSULATED REFRIGERATION TUBING BETWEEN EVAPORATOR COILS AND RECOMMENDATIONS. DUCT SIZES NOTED ON DRAWING ARE SHEET METAL DIMENSIONS. CONDENSING UNITS PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR MAY UTILIZE 2. ALL SUPPLYAND OUTSIDE AIR DUCTWORK SHALL BE WRAPPED WITH 1-1/2 INCH OF 0.75 LBfCU.FT. REFRIGERANT LINE SETS AS FURNISHED BYTHE CONDENSER MANUFACTURER. FIBERGLASS, FOIL BACKED DUCT WRAPPING. 3. REFRIGERANT LINE SET PENETRATIONS THROUGH THE ROOF SHALL BE PER THE BUILDING OWNER AND 3. ALL DUCTWORK EXPOSED ON THE EXTERIOR OF THE BUILDING SHALL BE COMPLETELY INSULATED ARCHITECTS REQUIREMENTS. SEE PLANS FOR DETAILS. WITH 21NCH THICK 6# DENSITY, PLAIN FACED, RIGID FIBERGLASS BOARD INSULATION. INSULATION ON THE TOP OF THE DUCTS SHALL BE SLIGHTLY SLOPED TO ALLOW FOR WATER DRAINAGE INSULATION C. AIR HANDLING UNIT AND DUCTWORK SHALL BE COMPLETELY COVERED WITH VENTURECLAD 1577CW JACKETING ..................................................................................0-GEBBRAWINGfOR INDIVKOUAL•JNFPPERFQRMANOE REQU#CEMENTS•...................... KEPTTOAMINIMUM. LONGITUDINAL JOINTS SHALL BE MADE ON THE BOTTOM OFTHE DUCTWORK INSTALLATION SHALL BE COMPLETELY WATER TIGHT. D. FANS 4. ALL KITCHEN HOOD EXHAUST DUCTWORK SHALL BE INSULATED WITH ETS FLAME SHIELD FIRE STOP BLANKET OR 3M FIRE BARRIER BLANKET. 1. ROOFMOUNTEDFANS a. SEE DRAWING FOR INDIVIDUAL UNIT PERFORMANCE. III. HVAC A.GENERAL M. CONTROLS A CONTROL WIRING SHALL BE PLENUM RATED CABLE WITH COLOR CODED 18AVVG WIRES (MINIMUM). 1. THE PROJECT CONSISTS OF INSTALLATION OF EXHAUST FAN, AIR DISTRIBUTION SYSTEM, HVAC SPLIT B. CONTRACTOR SHALL PROVIDE ALL WIRING BETWEEN THERMOSTAT AND EQUIPMENT (AIR HANDLER, ROOFTOP SYSTEM AND ALL ASSOCIATED CONTROLS, ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, ETC. UNIT, CONDENSING UNIT, ETC.). MUST BE FIELD VERIFIED FOR EXACT LOCATION. C. CONTRACTOR SHALL FURNISH AND INSTALL 120 VOLT SUPPLY AIR DUCT MOUNTED PHOTOELECTRIC SMOKE DETECTOR. DETECTOR SHALL BE WIRED, BY THE ELECTRICAL CONTRACTOR, TO SHUTDOWN UNIT UPON B. PIPING ACTIVATION. D. LOCAL CONTROL PANELS SHALL BE PROVIDED FORALL RELAYS, TRANSDUCERS, AND OTHER FIELD 1. MATCH EXISTING MATERIAL WHERE MODIFICATIONS ARE BEING MADE TO AN EXISTING SYSTEM. IF INTERFACE DEVICES. MATERIAL DIFFERS FROM THAT SPECIFIED HEREIN, IT SHALL BE SPECIFIED IN THE BID PROPOSAL. 1. PANELS SHALL BE NEVA TYPE SUITABLE FOR EACH APPLICATION. 2, CHILLED WATER PIPING SHALL BE ASTM A53, SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE WITH 2. ALL WIRING IN PANEL SHALL BE ROUTED IN WIRING TRAYS. ............. «... «.... «.......« ............... •.........»...................... 9• • PRQVK)r-F4NAL•, AS•NU 'P QNTROt DRAWNG MOUOTEDiKSIDE•TtiC-PANEL• • • • • • ............ • • • DRAWN COPPER PIPEWITHWROUGHT COPPER FITTINGSAND 95.5 SOLDERED JOINTS FOR 2"AND 4. CONTRACTOR SHALL PROVIDE ALL WIRING AND/OR TUBING BETWEEN CONTROL PANELS) AND REMOTE SMALLER. CONTROL DEVICES. 3. CONDENSER AND TOWER WATER PIPING SHALL SEASTM A53, SCHEDULE 40, SEAMLESS, BLACK STEEL .«.««.»............«..««"«.•«.............. ««.«.•«.....«.»...«.•«......... 43 THERMOSTAT'S .............. I........................................................ COPPER DRAWN COPPER PIPE WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS FOR 2" AND SMALLER. 1. FURNISH AND INSTALL A HONEYWELL 7 DAY PROGRAMMABLE HEATINGICOOLING THERMOSTAT AND 4. HEATINGHOTWATERPIPINGSHALLBEASTMA53,SCHEDULE44SEAMLESS, BLACK STEEL PIPE WITH CLEAR LOCKABLE COVER WITH APPROPRIATE CONTROL WRING BETWEEN THERMOSTAT AND AND AS ...... • - . ..«».-... • . «............«.......«..........•........................ REGB9PfD•TOPRGVIDE•AGQMR&TE-OPERAIiNGSY6TEMr WRPIOSHAL4.•BEMK74MUM48AW8............ ER PIP DRAWN COPPER PIPE WITH WROUGHT COPPER FITTINGS AND 95S SOLDERED JOINTS FOR2•AND 2. THERMOSTATS SHALL BE MOUNTED WHERE INDICATED ON THE DOCUMENTS. SMALLER. 3. CONTRACTOR SHALL PROGRAM THERMOSTAT PER THE OWNERS REQUIREMENTS AND TRAIN OWNER'S 5. STEAM PIPING SHALL BE SCHEDULE 40,ASTM-A53 STEEL PIPE. INSTALL STEEL PIPE WITH THREADED PERSONNEL IN THE OPERATION AND PROGRAMMING OF THE THERMOSTAT AND SYSTEM. JOINTS AND MALLEABLE -IRON THREADED FITTINGS FOR 2- AND SMALLER, AND WITH WELDED JOINTS FOR 2-112"AND LARGER. F. TEMPERATURE SENSORS 6. STEAM CONDENSATE RETURN PIPING SHALL SCHEDULE 80,ASTM-AS3 STEEL PIPE. INSTALL STEEL PIPE WITH THREADED JOINTS AND MALLEABLE -IRON THREADED FITTINGS FOR 2"AND SMALLER, AND WITH 1. FURNISH AND INSTALL THE TEMPERATURE SENSORS WITH APPROPRIATE CONTROL WIRING BETWEEN WELDED JOINTS FOR 2-1t2°AND LARGER. THERMOSTAT AND AHU AS REQUIRED TO PROVIDEACOMPLETE OPERATING SYSTEM. WIRINGSHALL 7. VALVES SHALL BE AS MANUFACTURED BY MILWAUKEE OR EQUIVALENT. ALLADDITIONALSTEAM BE MINIMUM i8AWG. SPECIALTY ITEMS (STEAM TRAPS, AIR VENTS,STRAINERS, ETC) NOT SPECIFIEDON THE DRAWINGS TO 2. TEMPERATURE SENSORS SHALL BE MOUNTED WHERE INDICATED ON THE DOCUMENTS. 8E AS MANUFACTURED BYSPIRAXSARCO OR EQUIVALENT. 8. ..... «......... «» .. «....».»....«................................. » .........VIM.. • TESTINGAND BAFANGING...................................................... HANDLING UNIT IN STALLED PER THE MANUFACTURERS REQUIREMENTS AND DETAILS. DRAIN SHALL DISCHARGE INTO AN EXISTING FLOOR DRAIN. A TESTING AND BALANCING SHALL NOT BEGIN UNTIL THE SYSTEM HAS BEEN COMPLETED, IS IN FULL WORKING 9.^••^•--••^^^•--•-•......•-•^^•......••--^^•-••••......•••••••••••••••••ORDER AND.ALUEGBIPMENT STARTUP HA8656NCOMPLETE0.•AUL-HVAG 6YBTEM&ANDCOUIPMENT SHALL MOUNTED AIR CONDITIONING UNIT, INSTALLED PER THE MANUFACTURERS REQUIREMENTS AND BE PUT INTO FULL OPERATION AND THE OPERATION OF SAME CONTINUED DURING EACH WORKING DAY OF DETAILS. DRAIN SHALL DISCHARGE INTOA ROOF DRAIN. THE TESTING AND BALANCING. 10. REFRIGERATION PIPING SHALL BE COPPER TYPE ACR WITH SILVER BRAZED JOINTS OR INDUSTRY ................«.......................................................... 8, AN MiDEPENDEN'f "AABG"•OR%E88"•GERTIFIEUAIR AND WATER BAkANOE•GONTRACTOR SNAL{•TEST AND THROUGH ROOF WITH PREFABRICATED PIPE CURBS. SEAL ROOF PENETRATIONS WEATHER TIGHT. BALANCE THE SYSTEM AND REPORT RESULTS TO THE ENGINEER AND THE OWNER. 11, PIPE HANGERS SHALL BE ADJUSTABLE CLEWS HANGERS WITH APPROPRIATE CLAMP(DEPENDING ON i. ALL WORK SHALL BE DONE UNDER DIRECT SUPERVISION OF THE CERTIFIED BALANCING ENGINEER AND STRUCTURE). PROVIDE OVERSIZED HANGERS FOR PIPING SYSTEMS THAT ARE TO BE INSULATED, BY QUALIFIED BALANCING TECHNICIANS. COORDINATE INSTALLATION WITH INSULATOR FOR RIGID INSULATION UNDER HANGERS. 2. METHODS AND FORMS SHALL BE IN ACCORDANCEWfiTH THE CERTIFICATION AGENCIES 12. ALL PIPING SHALL BE SUPPORTED ON A MAXIMUM OF IO'CENTERS EXCEPT COPPER PIPING 1414"AND RECOMMENDATIONS AND REQUIREMENTS. SMALLER SHALL BE SUPPORTED ON AMAXIMUM OF 6'CENTERS. 3, COMPLY WITH ASHRAE RECOMMENDATIONS PERTAINING TO MEASUREMENTS, INSTRUMENTS, TESTING, ADJUSTING AND BALANCING. C. DUCTWORKAND AIR DISTRIBUTION 4. ALL QUANTITIES SHALL BE WITHIN 10% OF THE DESIGN VALUES. 5. CONTRACTOR SHALL PROVIDE ANY SHEAVE CHANGES REQUIRED ON THE HVAC UNIT. 2. EACH CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK CAUSED BY HIS 1. DUCTWORK OR RECTANGULAR OR SPIRAL) SHALL BE OF GALVANIZED STEEL CONSTRUCTION WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB -TRADE'S PERSONNEL. ALL PATCHING, ......•^•-•••^••«^••^••^••^•^••-•••••^•^»•^••••»•••••••••••••••......••••G,PUMRALIGNME44T SPAC-99CHEaKEDAND.SHALL86 RE•AEIGYEDBPAQYALIFIEPTSGHNICIAN. REPAIRING, REPLACEMENTAND PAINTING,ETC. SHALL BE DONE AS DIRECTED BY THE OWNER BY TNE••••••••••••••••••••«•••......••••••••••••..... .••••••.......... .••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••........................•. CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORKSHALL BE PAID BY THE SCHEDULE: D. PERFORMANCE TEST CONTRACTOR CAUSING THE DAMAGE. a. SUPPLYAIR DUCTWORK4'WG. POSITIVE PRESSURE, SEAL CLASS B. b. RETURN DUCTWORK-PW.G.n1ftTNEPRESSURE,SEALCLASS B. 1. AFTER ALL HVAC EQUIPMENT IS INSTALLED, TESTED AND BALANCED AS SPECIFIED HEREIN THEY SHALL E. METHODS c.•••••••^•^••^--••--•^•-•^^•••••-^•^•••-^ BEOPERATEDAND PLACED UNDER SURVEILLANCE FOR A PERIOD OFAT LEASTONE (1) DAY, THIS MAY 2, ROUND DUCT ELBOWS SHALL BELONG SWEEP,1-112 TIMES THE CENTERLINE RADIUS UNLESS INCLUDE THE DAYOF STARTUP, TOVERIFY THAT ALL EQUIPMENT IS PRODUCING THE REQUIRED 1. EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, CLEARANCE IS NOT AVAILABLE AT WHICH TIME MITERED ELBOWS WITH TURNING VANES SHALL BE CAPACITY. THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR THE OPERATION OF THE EQUIPMENT CONDUIT OR DUCTWORK, ROOF DECK OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM UTILIZED. DURING THE ENTIRE PERIOD, ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND 3. RECTANGULAR ELBOWS SHALL BE FURNISHED WITH DOUBLE THICKNESS TURNING VANES. TURNING 2. TEST SHALL BE PERFORMED WITH ALL CONTROLS IN THE AUTOMATIC POSITION AND BUILDING LIGHTS, STRUCTURAL ENGINEER. VANES SHALL BE FASTENED WITH A DOUBLE ROW OF SCREWS. DAMPERS, ETC. POSITIONED TOSINDLATE NORMAL OPERATION OF THE HVAC SYSTEM. 2. ALL ROOF PENETRATIONS, FLASHINGS AND COUNTER FLASHINGS SHALL BE PERFORMED BY THE 4. FLEXIBLE CONNECTIONS AT THE INLETAND OUTLET OFAHU'S CENTRIFUGAL FANS. INSTALLFLEXIBLE 3. DURING THE TEST, CONTROL SETTINGS MAY REQUIRE ADDITIONAL ADJUSTMENTS TO PRODUCE THE OWNER'S ROOFING CONTRACTOR AT THE REQUESTING CONTRACTOR'S COST. CONNECTIONS WITH 3'WIDE DOUBLE NEOPRENE COATED FLAME RETARDANT, NFPA90AAPPROVED, BEST BALANCED SYSTEM OPERATION. THEIR FINAL SETTING OF EACH OPERATING AND SAFETY FIBERGLASS FLEXIBLE CONNECTION. FLEXIBLE CONNECTION TO HAVE AMINIMUM OF24 GAGE, TWIDE CONTROL SHALL BE RECORDED, THEY SHALL INCLUDE, BUT NOT LIMITED TO, THERMOSTATS, LIMIT F. SUBMITTALS SHEET METAL COLLARS PERMANENTLYATTACHED TO EACH SIDE. CONTROLS, AND OTHER SIMILAR ITEMS. 5. MITERED OFFSETS GREATER THAN 30 DEGREES IN EITHER DIRECTION SHALL NOT BE PERMITTED. 4. SHOULD COMPLETION OF THE INSTALLATION OCCUR AT SUCH TIME THAT THE REQUIRED 1. SHOP DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT OF ALL EQUIPMENT AND ACCESSORIES 6. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE PERFORMANCE TEST MUST BE CONDUCTED DU RING ASEASON WHEN THE FULL OPERATION OF 7M PROVIDED FOR THE PROJECT WHETHER SPECIFIED HERE -IN OR ON THE DRAWINGS. REVIEWOF THE ANGLE OF DIVERGENCE OF iSDEGREES. THE HEATING OR COOLING SYSTEM CAN NOT BE CHECKED, THE CONTRACTOR SHALL PERFOR T rr SHOP DRAWNGS SHALL BE FOR GENERAL DESIGN CONCEPT AND ADHERENCE WITH THE 7. RECTANGULAR BALANCING DAMPERS- RUSKIN M025 SHALL BE SINGLE BLADE UP TO W IN HEIGHT AND TEST AND RECORD ALL SUCH DATA AS IS AVAILABLE WITH SYSTEM OPERATING AUTOMATICALL P SPECIFICATIONS QUANTITY OF SHOP DRAWINGS SUBMITTED SHALL BE AS SPECIFIED BY THE 36- IN WIDTH, AND RUSKIN MD35 MULTI -BLADE FOR LARGER SIZES. ALL ROUND BALANCING DAMPERS THE PREVAILINGWEATHER CONDITIONS. THAT PART OF THE SYSTEM WHICH CANNOT BETESTD,. ARCHITECT. SHOP DRAWINGS SHALL BE PREPARED BY THE CONTRACTOR SHOWING LOCATIONS AND SHALLSE COMMERCIAL GRADE SINGLE BLADE UP TO 16' IN DIAMETER SHALL INCORPORATE LOCKING SHALL BE DELAYED UNTIL THE WEATHER IS APPROPRIATE, ATWHICH TIME THE REMAINING PAR OF MEASUREMENTS FROM COLUMNS OF ALL CONCEALED AND EXPOSED PIPING, DUCTWORK, CONDUIT, TYPE INDICATING ADJUSTMENT. BALANCING DAMPERS SHALL BE INSTALLED IN ALL BRANCH DUCTS OFF THE REQUIRED TESTS SHALL BE CONDUCTED AND DATA RECORDED ACCORDINGLY. EQUIPMENT, ACCESSORIES,ETC., AND SUBMITTED PRIOR TO INSTALLATION. THE OWNER MAY MAKE MAIN AND ON ALL TAPS OFF DUCTS TO DIFFUSERS UNLESS OTHERWISE NOTED ON DRAWINGS. REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILABLE FOR USE IN PREPARATION OF SHOP 8. FINAL CONNECTIONS TO DIFFUSERS MAY BE MADE WITH FLEXIBLE AIR DUCTWORK BUT ITS USE IS E. ACCEPTANCE AND CHECK-OUT- CONTRACTOR SHALL PROVIDE QUALIFIED PERSONNEL, AT NO ADDITIO At 1507 Bei..m Ave, Suite 200 Seattle, Washington 9B122 2W.323.9932 IRAWN BY: STK CHECKED BY: KDH (DT/E/S ENGINEERING 25760 First Street P 440 $71 2410 Cleveland, OH 44145 F 440 8717954 City of Tukwila Approval Stamp: BID SET May 10, 2019 Homegrown at Southcenter 841 Southcenter Mall Space #532 Seattle, WA 98188 Project No. 1906 Date: May 10, 2019 Revision: VIEWED FOR Scale: AS NOTED IE COMPLIANCE APPROVED Sheet contents: JUL 192010 MECHANICAL DRAWINGS, HOWEVER THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR NOT CONFIRMING ALL LIMITED TO STRAIGHT HORIZONTAL OR VERTICAL RUNS. ALL CHANGES OF DIRECTION IN A DUCT COST TO THE OWNER, AS MAYBE REQUIRED BY THE ENGINEER FOR THE PURPOSE OFVERIFYING PRO R' Cltyof Tukwila SPECIFICATIONS INFORMATION ON THE DRAWINGS PRIOR TO FABRICATION AND/OR INSTALLATION. SYSTEM (GALVANIZED OR FLEXIBLE) SHALL BE MADE WITH AN APPROPRIATE GALVANIZED ELBOW. OPERATION AND INSTALLATION OF THEIR WORK ATTHE TIME OF REQUEST FOR ACCEPTANCE. DIVISIOIN 2. PROJECT RECORD DOCUMENTS-MAINTtVNATTHEJOBSITEONECOPYOFALLCONTRACTDOCUMENTS MAXIMUM LENGTH OF ANY FLEXIBLE AIR DUCT IS64r. BUILDING •••••••«•••••»•.•••••••.•••••»•••............................................ 9.••FLEXIBLE•AIR DUCTSTODIFFUSERS6HALL-BS ATGG RUBBERi'RODUOT6f Wo. MODELUP04079'••• VIM!. SEQUENCE OF OPERATION CONDITION, UPDATED DAILY FOR CHANGES ENCOUNTEREDAND AVAILABLE AT ALL TIMES FOR INSULATED (R=4.2),U.L. 181 RATED AND CLASS I AIR CONNECTOR. MAXIMUM LENGTH OF FLEXIBLE AIR Sheet: INSPECTION BY THE OWNER. DO NOT USE FOR FIELD CONSTRUCTION! PROJECT RECORD DOCUMENTS DUCT TO DIFFUSER TO BE 6-17. A SPLIT SYSTEM COOLING UNIT ARE TO BE KEPT CURRENT WITH EXACT DIMENSIONS OF ALL WORK, EQUIPMENT, PIPING, VALVES, 10. FLEXIBLE CONNECTOR DUCTS AT THE INLETS OF THE NEWVAV BOXES SHALL BEATCO RUBBER 1. IN THE OCCUPIED/ UNOCCUPIED MODE THE EVAPORATOR FAN SHALL START WITH ACALL FOR COOLING DUCTWORK ETC. MARKALL INFORMATION IN RED LINES AND NOTES BOAS TO BE EASILY IDENTIFIED PRODUCTS, INC. MODEL UPC #050, UN -INSULATED, U.L 181 RATEDAND CLASS I AIR CONNECTOR, AWALL MOUNTED THERMOSTAT SHALL START THE ASSOCIATED AIR COOLED CONDENSING UNITAND FROM THE BASE DRAWING. UPON COMPLETION OF THE WORK ONE SET OF THESE DOCUMENTS SHALL BE TURNED OVER TO THE OWNER AS ONE QUALIFICATION FOR FINAL PAYMENT. MAXIMUM LENGTH OF FLEXIBLE DUCT AT BOX INLET TO BE T-T. ii. SUPPORT ALL SHEET METAL AND EQUIPMENT FROM ANGLE IRON CONNECTED TO STRUCTURAL STEEL STAGE THE COMPRESSOR TO MAINTAIN ROOM TEMPERATURE SETPOINT. R E C E IY ED CITY O� Ti:I<b'r`i L1� 3. AFTERTHE BALANCING AND ACCEPTANCE TESTS ARE COMPLETED AND ACCEPTED BY THE OWN ER, DO NOT SUSPEND DUCT OR EQUIPMENT FROM METAL DECK OR JOIST BRIDGING. n THREE COMPLETE SETS OF AS -BUILT DOCUMENTATION SHALL BE PROVIDED. IT SHALL INCLUDE, BUT NOT BE LIMITED TO ACCURATE PLAN DRAWINGS, SYSTEM AND CONTROL SCHEMATICS, SEQUENCE OF 3'vn 211 te1eJ OPERATION, WIRING DIAGRAMS AND OPERATION AND MAINTENANCE MANUALS. PEPMIT CENTER I MECHANICAL PLAN M1.0 SCALE: 1/4-f-O° GENERAL SHEET NOTES 1. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 2. SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WRING SHALL BE LABELED PLENUM RATED PER NFPA 70. 3. LIMITED ABOVE CEILING CLEARANCES EXIST. COORDINATE LOCATION AND ELEVATION OF MECHANICAL NARK WTH ALL DUCTWORK, SPRINKLERS, LIGHT FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. 4. COORDINATE ALL THERMOSTAT AND SENSOR LOCATIONS NTH FURNITURE LAYOUT AND ARCHITECTURAL PLANS. DEVICES ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR, MOUNT PER ADA REQUIREMENTS, 5. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 15 DEGREE. 6. DUCT SIZES INDICATED REPRESENT EXTERNAL SHEET METAL DIMENSIONS AND INCLUDE ALLOWANCE FOR INTERNAL INSULATION. j 7. ALL UNLINED SUPPLY AIR DUCTff)RK NOT EXPOSED SHALL BE EXTERNALLY INSULATED. 8. BRANCH DUCTS SERVING DIF7ERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED UNLESS NOTED OTHERWSSE. O SHEET KEYNOTES 1 CONNECT REFRIGERANT PIPING TO AHU-1 PER MANUFACTURER'S RECOMMENDATIONS. EXTEND REFRIGERANT PIPING AS SHOWN UP TO CU-1 ON ROOF ABOVE. FIELD VERIFY EXACT LOCATION OF ROUTE PRIOR TO BID. 2 ROUTE 20120 OUTSIDE AIR DUCT TO ROOF ABOVE. SEAL ALL ROOF PENETRATIONS WEATHER TIGHT. FIELD VERIFY EXACT SIZE AND LOCATION OF DUCTNARK PRIOR TO BID. 3 P CONDENSATE PIPING. ROUTETO BACK OF HOUSE FLOOR DRAIN. TERMINATE WITH 4° AIR GAP AT FLOOR DRAIN. 4 MOUNT REMOTE CONDENSING UNITS) FOR WALK IN COOLER ON ROOF ABOVE. MOUNT ON PRE MANUFACTURED PATE EQUIPMENT RAILS. SEAL ALL ROOF PENETRATIONS WEATHER TIGHT. ALL REFRIGERANT PIPING PENETRATIONS SHALL UTILIZE PRE MANUFACTURED PIPE PENETRATION CURBS. 5 MOUNT THERMOSTAT AT NOTED LOCATION. MOUNT AT 48°AFF PER ADA REQUIREMENTS. 6 ROUTE 10110 EXHAUST DUCT UP TO EF-1 MOUNTED ON ROOF CURBABOVE. TRANSITION TO FULL SIZE CURB OPENING AT UNIT AND PROVIDE FLEX CONNECTION AT UNIT OUTLET. 7 PROVIDE 30126 OPENING IN TOPOF LINED RETURN AIR DUCT. COVER OPENING WITH 112'WRE CLOTH. 8 MOUNT REMOTE SENSOR FOR THERMOSTATIC DIFFUSERS AT NOTED LOCATION. COORDINATE FINAL LOCATION OF SENSOR WTH ARCHITECT. 9 SMOKE DETECTOR MOUNTED IN RETURN AIR DUCT. PROVIDED AND W RED BY EC. INSTALLED BY MC. 10 CONNECT SUPPLY AND RETURN AIR DUCTS TO AHU OUTLETS. PROVIDE FLEX CONNECTION AT UN IT OUTLET. TRANSITION TO NOTED SIZE DUCT ON PLANS. 11 PROVIDE AND INSTALL MIXING BOX WTH 100% ECONOMIZER CONTROL WTH FDD. 12 REMOTE KEY TEST STATION FOR SMOKE DETECTOR. CALL AND COORDINATE FINAL LOCATION WTH LOCAL FIRE DEPARTMENT. RECEIVED CITY OF TUKWILA 4 'KO PERMIT CENTER 1 <.