HomeMy WebLinkAboutPermit M19-0112 - TRAPPER'S SUSHI - WALK-IN BEER COOLER AND REFRIGERATION EQUIPMENTSTRAPPER'S SUSHI
468 SOUTHCENTER MALL
EXPIRED
01/21/2020
M19-0112
Parcel No:
0
�~^�«x ^�� �� l"°"^U
^~U~n v�n v U�mmm�oa
Department Development
hyonsoutocenterBoulevard, uuue#zuu
Tukwila �VVashinQmn98188
n�""~'�n�-un/'��ro
''----- -----
Inspection Request Line: 2V5-43g-935O
Web site: http://www.TukwilaWA.Rov
9202470010
Project Name: TRAPPER'S SUSHI
MECHANICAL PERMIT
Permit Number: K819-0112
Issue Date: 7/25/2019
Permit Expires On: 1/21/2020
Address:
Contact Person:
WESTFIELD PROPERTY TAX DEPT
POBOX l]U940'C4RLSBAD'WA,
92013
Address: 79072I2TH5T5VV#100,EDMONDS,
WA, 98026
Contractor:
Name: POLAR BEAR MECHANICAL INC
Address: 4OlNEpAVENNA8LSUITE l3O'
SEAlTLE WA, 98116
License No: POLxR8x8891PC
Lender:
Name:
Address:
Phone: (360)202-7115
Phone: (425) 967-5827
Expiration Date: 10/3/2019
DESCRIPTION OF WORK:
|M5TALAT0NOFCUSTOMER PROVIDED CUSTOM WALK |N BEER COOLER AND ASSOCIATED REF|RGERAT|ON
EQUIPMENTS.
Valuation of Work: $2,475.00
Type ofWork: NEW
Fuel type: ELECT
Fees Collected: $24569
Electrical Service Provided by: PUGETSOUND ENERGY
Water District: TUKVV|LA
Sewer District: TUKVV|LA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
rized Signature:
ational Electrical Code:
VVACities Electrical Code:
vVACZ9646B:
Code:
�`
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
d agree to tconditi9ns attached to this permit.
development per ita
Signature:
Print Name:
1-
1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval,
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage
over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic
events. The design and calculations for the anchorage or bracing shall be prepared by a registered
professional engineer licensed in the State of Washington. Periodic special inspection is required during
anchorage of storage racks 8 feet or greater in height.
5: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: ***MECHANICAL PERMIT CONDITIONS***
10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
11: Manufacturers installation instructions shall be available on the job site at the time of inspection.
15: Fire protection systems shall be maintained in accordance with the original installation standards for that
system. Required systems shall be extended, altered or augmented as necessary to maintain and continue
protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems
shall be done in accordance with applicable standards. (IFC 901.4)(EXTEND SPRINKLER PROTECTION TO
WALK-IN COOLER.)
13: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3)
lZ: All new sprinkler systems and all modifications toexisting sprinkler systems shall have fire department
review and approval ofdrawings prior toinstallation ormodification. New sprinkler systems and all
modifications tosprinkler systems involving more than 50heads shall have the written approval ofFactory
Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior to submittal tothe Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. <OtyOrdinance No. 2430).
14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#Z436and #2437)
16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval ofsuch condition orviolation.
17: These plans were reviewed byInspector 5l1. |fyou have any questions, please call Tukwila Fire Prevention
Bureau ct(2U6)575-44O7.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206)43W-935O
1400 FIRE FINAL
1800 MECHANICAL FINAL
0609 P|P[/DU[T|NSULAJ|ON
0705 REFRIGERATION EQUIP
0701 NOUGM'|NN1E[MAN|[AL
CITY OF TUKWI
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite .100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. in / ()//
Project No.
Date Application Accepted: 7- /0- /
Date Application Expires: /0 -70
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: Libs. fA g Suite Number:
Tenant Name: pio-ri S. 5 s
PROPERTY OWNER
Name:
Address: *
L zg 1(
NE, (14, ti, 13 lq c-C_
City: 14. t "r tx.
,,i,
State: v A_ Zip: eNO3y
CONTACT PERSON - person receiving all project
communication
Name: i•-' ) kar
6-.r-
Address:
3-10 St.. Rd 400
City: cat.v.„.6.4s State:
CAM- ,P6r2,6
Phone: Fax:
3G0 Z.01,7115"
Email: q trAi I r btkoptec 4 qvi ick, ,r,
New Tenant:
Floor:
Yes
.. No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Pe lit r fig--i Aett Q.. k..Q , h,e.
Address: ..c(09. ficaie4 9_ SW *4 t 00
City: Stateov zo„..era
Phone: , Fax:
SF(Zt-
Contr Reg No.: Exp Date:
Tukwila Business License No.: (3,us ... 0 ,, 7
Cfl3i 0 3 1 (159 g
Valuation of project (contractor's bid price): $ 2_ ti -:7-
Describe the scope of work in detail: 5 1-‘Al-f-l'el", r
4?,exer- (Data/ ck s ect. ler)
(Id Cat slo,,
vl
Use:
Residential: New
Commercial: New
Fuel Type: Electric
Replacement
Replacement
Gas 0 Other:
HAApplications \ Forms -Applications On Line \ 2016 ApplicationsliMechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
Page 1 of 2
•
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler '
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-10pm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 R OR U HOR ZED AGENT:
Signature:
Print Name: aq rte S
Mailing Address: "--4" ereq-
54- sw
Day Telephone: Z� 2- 76Z-3
0 s c,Ati 77e a6
City State
Zip
ApplicationsWorms-Applications On Line120 I 6 Applications\ Mechanical Permit Application Revised 1-4-16.docn
Revised: January 2016
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$245.69
M19-0112 Address: 468 SOUTHCENTER MALL Apn: 9202470010
$245.69
Credit Card Fee
$7.16
Credit Card Fee
R000.369.908.00.00
0.00
$7.16
MECHANICAL
$229.36
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
5150,34
PLAN CHECK FEE
R000.322,102.00.00
0.00
$45,87
TECHNOLOGY FEE
$9.17
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$9.17
TOTAL FEES PAID BY RECEIPT: R18090
$245.69
Date Paid: Wednesday, July 10, 2019
Paid By: CHARLES LIGHTSEY
Pay Method: CREDIT CARD 03611J
Printed: Wednesday, July 10, 2019 11:34 AM 1 of 1
CO TUKWILA ETRAKIT
6280 B]UTH[ENTER BLVD
TUKWILA' WA 98188
206'433'1870
CITY OF TUKWIL4
0017340000882374404500
Date: 07/10/2019 1I:33:55 AM
CREDIT CARD SALE
MASTERCARD
X
�CARDHOLDER'S SIGNATURE)
I AGREE TO PAY THE ABOVE TOTAL AMOUNT
x[[0RoImG TO THE CARD ISSUER AGREEMENT
(MERCHANT AGREEMENT IF CREDIT VOUCHER)
Thank you!
Merchant Copy
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK , GROVE
ENG NEEF''.'NG
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
BRIAN J. SIELAFF, P.E.
STRUCTURAL ENGINEERING CALCULATIONS
FOR
CUSTOM COOLER, INC.
TRAPPER SUSHI (BEER COOLER)
TUKWILA, WA
TGE PROJECT NO.: TGE19-12562
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 2 4 2019
City of Tukwila
BUILDING DIVISION
DESIGN CRITERIA:
STRUCTURAL CODE:
SEISMIC PARAMETERS:
05/28/19
STA MP
SEISMIC DESIGN CATEGORY:
MINIMUM INDOOR LATERAL LOAD:
WALL/CEILING DEAD LOAD:
INDOOR CEILING LIVE LOAD:
FILE
RECEIVED
CITY OF TUKWILA
JUL 1 0 2019
PERMIT CENTER
141 0112.
2015 IBC
Ss = 1.463 g
Si = 0.546 g
D
5.0 PSF
5.0 PSF
10.0 PSF
812 S. La Cassia Dr. - Boise, Idaho 83705 (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TACK Tr GRO
1 N E E R I N G
TABLE OF CONTENTS
Project Herne: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Plumber: TGE19-12562
z SCOPE OF WORK 3
2 PROJECT INFORMATION...... ........... ...................................................•...,.......................•., ...,.......... ....... . ....,
3 JURISDICTIONAL INFORMATION 4
4 ICC EVALUATION REPORT, PRODUCT SPECIFICATION LITERATURE AND DESIGN AIDS 5
5 GENERAL STRUCTURAL NOTES 6
6 SEISMIC ANALYSIS
7 STRUCTURAL ENGINEERING CALCULATIONS9
8 SOFTWARE PRINTOUTS i6
8.1 HILT' PRINTOUTS i6
g MATERIAL AND HARDWARE PRINTOUTS 21
9.1 CUSTOM COOLER LARR 25690 21
7
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
ENGINEERING
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
SCOPE OF WORK
Tamarack Grove Engineering is providing structural engineering calculations for the walk-in cooler manufactured by CCI
Global DBA Custom Cooler to verify the structural integrity of the panels and anchorage to the slab. The design of the
slab/foundation is to be provided by others. Redline drawings provided to the client as needed based on calculations and
code requirements.
2 PROJECT INFORMATION
Tamarack Grove Engineering
TGE Project Number:
Date:
TGE Contact:
TGE Engineer of Record:
Project Client Information:
Company:
Contact:
Address:
Phone:
Email:
Client Logo:
Project Site Information:
Name:
Address:
Coordinates:
Phone:
Email:
Site Elevation:
Live and Dead Loads
Ceiling Live Load:
Ceiling Dead Loads:
Steel Facing (ASTIVI-A-646):
Insulation:
Miscellaneous:
TOTAL:
TGE3.9-12562
5/28/2o3.9
Ian McClure
Brian J. Sielaff, P.E.
CUSTOM COOLER INC.
Rick Kay
420 E. Arrow Highway
San Dimas, CA 91773
909-592-un
rickk@a customcooler.com
Custom Cooler
CLC te Compaly
420 E. ARROW HIGHWAY
SAN DIMAS, CA 91773
TEL: (909) 592-1111
FAX: (909) 599-6225
Trapper Sushi (Beer Cooler)
468 Southwest Mall
Tukwila, WA 981.88
47.448° N, 122.282° W
N/A
N/A
N/A
io PSF
s.o PSF (26 GA. — t = 0,02 inch)
s.a PSF
3.0 PSF
5.o PSF
1005 GIGMAN ROAD NE
CONYERS, GA. 30013
TEL: (678) 712-5656
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK s GROVE
ENG NEERING
JURISDICTIONAL INFORMATION
Seismic Design Information:
Seismic Parameters:
Ss=1.463 9
Si=0.546 9
SDs=0.975 9
SDI=0.546 9
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
Seismic Design Category: D
Site Coefficient, FA: i.000
Site Coefficient, Fv: 1.500
Building Site Class: D
Analysis Procedure Used: Equivalent Lateral Force Procedure
for Non -Structural Components
Basic Seismic -Force -Resisting -System: Bearing Wall System — Light
Framed Walls of All Other Materials
Importance Modification Factor, IP: a.o (ASCE 7-io 13.1.3)
Amplification Factor, ap: z.o (ASCE 7-io Table 3.3.6-3.)
Response Modification Factor, Rp: 2.5 (ASCE 7-3.0 Table 13.6-1)
Lateral Pressure Design Information:
Maximum Indoor Lateral Load:
5.0
PSF
812 S. La Cassia Dr. Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK IT GROVE
E N G, N E E P IN G
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
4 ICC EVALUATION REPORT, PRODUCT SPECIFICATION LITERATURE AND DESIGN AIDS
+ CUSTOM COOLER INC. LARR 25690
• 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION
• ICC ESR-i.976, "ITW BUILDEX TEKS SELF DRILLING FASTENERS"
• AISC STEEL CONSTRUCTION MANUAL- �4TH EDITION
• ICC ESR-3027: "HILTI KWIK HUS-EZ (KH-EZ) AND KWIK HUS EZ i (KH-EZ 3.) CARBON STEEL SCREW ANCHORS FOR
USE IN CRACKED AND UNCRACKED CONCRETE"
812 S.'La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK FP GROVE
ENGINEER I N G
5 GENERAL STRUCTURAL NOTES
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
1. GENERAL STRUCTURAL NOTES:
A. CONTRACTOR TO VERIFY ALL OPENINGS, BUILDING DIMENSIONS, COLUMN LOCATIONS AND DIMENSIONS WITH OWNER PRIOR TO SETTING
OF ANY COOLER BOXES OR CONSTRUCTION.
B. THE ENGINEER OF RECORD 15 NOT RESPONSIBLE FOR ANY DEVIATIONS FROM THESE PLANS UNLESS SUCH CHANGES ARE AUTHORIZED IN
WRITING TO THE ENGINEER OF RECORD.
C. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SAFE AND ADEQUATE SHORING AND/OR TEMPORARY STRUCTURAL STABILITY FOR ALL
PARTS OF THE STRUCTURE DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR FINAL
CONFIGURATION.
D. NOTCHING AND/OR CUTTING OF ANY STRUTURAL MEMBER IN THE FIELD 15 PROHIBITED, UNLESS PRIOR CONSENT IS GIVEN BY THE ENGINEER
OF RECORD.
E. ALL FUTURE ROOF/CEILING MOUNTED EQUIPMENT NOT CURRENTLY SHOWN ON THE APPROVED SHOP DRAWINGS SHALL BE COORDINATED
WITH THE FOR PRIOR TO ANY INSTALLATION, TYP,
2. SPECIAL INSPECTIONS & TESTING (QUALITY ASSURANCE PLAN):
A. GENERAL:
1. INDEPENDENT TESTING LAB SHALL BE RETAINED BY OWNER TO PROVIDE INSPECTIONS AND SPECIAL INSPECTIONS AS DESCRIBED
HEREIN.
2, THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PROVIDING ON SITE ACCESS TO ALL REQUIRED INSPECTIONS AND
NOTIFIES TESTING LAB IN TIME TO PERFORM SUCH INSPECTIONS PRIOR.
3. DO NOT COVER WORK REQUIRED TO BE INSPECTED PRIOR TO INSPECTION BEING MADE. IF WORK 15 COVERED, CONTRACTOR WILL BE
RESPONSIBLE FOR UNCOVERING AS NECESSARY.
4. THE CONTRACTOR SHALL CORRECT ALL DEFICIENCIES AS NOTED WITHIN THE SPECIAL INSPECTION REPORTS AND/OR THE ENGINEER OF
RECORD'S FIELD OBSERVATION (STRUCTURAL OBSERVATIONS) REPORTS TO BRING THE CONSTRUCTION INTO COMPLIANCE WITH THE
CONTRACT DOCUMENTS, ADDENDUMS, REVISIONS, RFI'S AND/OR WRITTEN INSTRUCTIONS. THE CONTRACTOR IS RESPONSIBLE TO
REQUEST SUMMARY REPORTS FROM THE SPECIAL INSPECTOR AND ENGINEER OF RECORD AT THE TIME OF THE PROJECT SUBSTANTIAL
COMPLETION. PRIOR TO REQUESTING THE SUMMARY OF STRUCTURAL OBSERVATION REPORTS FROM THE ENGINEER OF RECORD, THE
CONTRACTOR SHALL SUBMIT TO THE ARCHITECT AND ENGINEER OF RECORD A LETTER STATING THAT ALL OUTSTANDING ITEMS NOTED
ON PREVIOUS STRUCTURAL OBSERVATION REPORTS HAVE BEEN COMPLETED IN ACCORDANCE. WITH THE CONTRACT DOCUMENTS,
ADDENDUMS, REVISIONS, RFI'S AND/OR WRITTEN INSTRUCTIONS,
B. SPECIAL INSPECTIONS:
1. ALL SPECIAL INSPECTIONS SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF THE 2016 CALIFORNIA BUILDING CODE (CBC) AS
RECOMMENDED BY THE LOCAL BUILDING JURISDICTION.
2. REQUIRED SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT CERTIFIED TESTING LABORATORY EMPLOYED BY THE
OWNER PER SECTION 1704 OF THE 2016 CBC.
3. THE INDEPENDENT CERTIFIED TESTING LABORATORY AND INSPECTORS SHALL BE A QUALIFIED PERSON WHO SHALL SHOW
COMPETENCE TO THE SATISFACTION OF THE LOCAL BUILDING OFFICIAL, OWNER, ARCHITECT AND ENGINEER OF RECORD FOR THE
PARTICULAR OPERATION. ALL SPECIAL INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT, ARCHITECT AND
ENGINEER OF RECORD STATING THE PROJECT NAME AND ADDRESS.
4. THE CONTRACTOR AND SPECIAL INSPECTOR SHALL NOTIFY THE ENGINEER OF RECORD OF ANY ITEMS NOT COMPLYING WITH THE
PROJECT SPECIFICATIONS, CONTRACT DOCUMENTS AND/OR APPLICABLE CODES BEFORE PROCEEDING WITH ANY WORK INVOLVING
THAT ITEM. THE ENGINEER OF RECORD WILL REVIEW THE ITEM AND DETERMINE ITS ACCEPTABILITY. IF WORK INVOLVING THAT ITEM
PROCEEDS WITHOUT PRIOR APPROVAL FROM THE ENGINEER OF RECORD, THEN THE WORK WILL BE CONSIDERED NON -COMPLIANT.
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
6 SEISMICANALYSIS
OTCHazards by Location
Search Information
TAMARACK ¶ GROVE
ENG- MEEPIN
Address: 468 SOUTHWEST MALL, TUKWILA, WA 98188
Coordinates: 47.4489305, -122.28291609999997
Elevation: 482 ft
Timestamp: 2019-05-22T17:00:39.816Z
Hazard Type: Seismic
Reference ASCE7-10
Document:
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
Redmond
S
tr7
rest
Kent
Tacoma
0
PlPfar tip
Go gle Map Report a map ena
Risk Category: II
Site Class:
MCER Horizontal Response Spectrum Design Horizontal Response Spectrum
Sa(g) Sa(g)
1.40
1.20 0.80
1.00
0.60
0.80
0.60 0.40
0.40
0.20
0.20
0.00 0.00
0 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Period (s) 0 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Period (s)
Basic Parameters
Name Value Description
Ss 1.463 MCER ground motion (period=0.2s)
Si 0.546 MCER ground motion (poricx1=1.0s)
Sms 1.463 Site -modified spectral acceleration value
Smi 0.819 Site -modified spectral acceleration value
SDS 0.975 Numeric seismic design value at 0.2s SA
Sul 0.546 Numeric seismic design value at 1.0s SA
',Additional Information
Name Value Description
SDC D Seismic design category
Fa 1 Site amplification factor at 0.2s
F, 1.5 Site amplification factor at 1.0s
812 S. La Cassia Dr. • Boise, Idaho 8 705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK 'Tr GROVE
ENG,NEERING
CRs 0.943 Coefficient of risk (0.2s)
CR1 0.93 Coefficient of risk (1.0s)
PGA 0.603 MCEG peak ground acceleration
F PGA 1 Site amplification factor at PGA
PGAm 0.603 Site modified peak ground acceleration
TL 6 Long -period transition period (s)
SsRT 1,463 Probabilistic risk -targeted ground motion (0.2s)
SsUH 1.552 Factored uniform -hazard spectral acceleration (2% probability of
exceedance in 50 years)
SsD 3.318 Factored deterrninistic acceleration value (0.2s)
S1RT 0.546 Probabilistic risk -targeted ground motion (1.0s)
Si UH 0.587 Factored uniform -hazard spectral acceleration (2% probability of
exceedance in 50 years)
S 0 1.068 Factored deterministic acceleration value (1.0s)
PGAd 1.198 Factored deterministic acceleration value (PGA)
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code
adoption process. Users should confirm arty output obtained from this tool with the local Authority Having A/nu/a:bon before proceeding with
design.
Disclaimer
Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services.
While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or
liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent
examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the
use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor
to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website.
Users of the information from this website assume al liability arising from such use. Use of the output of this website does not imply approval by
the governing building code bodies responsible ,`or building code approval and interpretation for the building site described by latitude/longitude
location in the report.
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK V GROVE
E 4
NEER iNG
7 STRUCTURAL ENGINEERING CALCULATIONS
JURISDICTION INFORM ,TION
JURISDICTION:
STRUCTURAL CODE:
WASHINGTON
INTERNATIONAL BUILDING CODE 2015
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
OK :=1
NG
DESIGN CRITERIA
SFTSMIC CRTTF,BIA
R:=2.5
z:=0 ft
Design Spectral Response for Short Period, (g)
Response Modification Factor
Importance Modification Factor
Height of Base off of the Ground
BASIC DESIGN VALUES
10 paf
PLL := 300 ibf
131'pant I 5 P8f
Anterrra/ 5 p8f
Cooler Panel Live Load
Imposed Live Load
Cooler Panel Dead Load
Minimum Indoor Lateral Load
ASD LOAD CO B NATIONS 7- 0
W3:=DL(+LLik,„A= 15 paf
Load Combination 3: D+(Lr, S, or R)
1 DESIGN CALCULATIONS:
Vilidth:=6.42 ft
Length := 8.08 ft
Lculirig := 5 in
t prancl
H:=8.5 ft
H„,:= 8.0.8 ft
PANEL MANUFACTURER: CUSTOM COOLER INC
Unit Width
Unit Length
Ceiling Panel Thickness (Worst Case)
Wall Panel Thickness (Worst Case)
Mean Ceiling Height
Mean Wall Height
PANEL SPECIFICATION: 5" WOOD FRAME URETHANE PANELS (LARR #25690)
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK ITT GROVE
ENG NEERING
2 'TYPICAL CEILING PAN
L:= 6.42 ft
kii= 10 ft
T width= 3.92 ft
LOADS:
• Td,, = 58•8 plj
Weciliny_fle-Nivrt • L 2 1LL • L
max = 481..5 ft • lbf
8 4
(t1.; rpilg
m firg
n r) . L
max- . PL L
2
=300 lbf
13( (Ili fr./ T width* 65 psf 254.8 PO
147 ail (.66140 • L all
ill allow := = 3185 ft. lbf
8
1.17 * =
V allow 1274 tbf
2
CHECK
'ma-r = 1 Vallow> Vnecir = 1
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
Design Length (Worst Case)
Corresponding Allowable Span (LARR 25690)
Tributary Width of Panel for Evaluation
(LARR 25690)
Uniform Load Acting on Ceiling
Maximum Moment (ENERCALC)
Maximum Shear (ENERCALC)
Allowable Panel Load (LARR 25690)
Allowable Moment
Allowable Shear
SUMMARY: THEREFORE, usza" WOOD FRAMED URETHANE FOAM PANELS FOR CEILING PER
PLAN
4) TYPICAL WALL PANEL
„,:= 8.083 ft
Talath_reib.ng:= 3.25 ft
Twidth := 3.92 ft
LOADS:
Design Height
Tributary Width of Ceiliing on Wall
Tributary Width of Ceiiing Panel
Vt0 Total Axial Load From
T eri fit lisciling f""pancl • 7- wirilltccif mg = 92,8 Pli Ceiling
width.
Hga_„..„.":= 31 ft Allowable Height for Axial Load (LARR 25690)
PuiLaxml'= 600 PO
wdf sign _waltz= Penternai • T width = 19•6 Pli
l_ru,. ft
Total Allowable Axial Load (LARR 25690)
Transverse Load on Wall
Allowable Height for Transverse Load
(LARR 25690)
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK GROVE
E GiNEERING
Wu := 65 psf • T width= 254.8 Of
Wdesign oiling Wiksign wall = 0.23
Reanthincd:=
P ail axial Wall
CHECK Rembincd< 1.0 =1
Project Name: TRAPPER SUSHI
Location:: TUKWILA, WA
TGE Job )4umber: TGE19-12552
Total Allowable Transverse Load
Combined Axial and Bending Ratio
SUMMARY: THEREFORE, USE 5" WOOD FRAMED URETHANE FOAM PANELS FOR WALLS PER
PLAN,
GRIDLINFS I AYOIEL.
PER ASCE 7-10 CHAPTER 15, SECTION 15.1.3, "STRUCTURAL ANALYSIS PROCEDURES FOR NONBUILDING
STRUCTURES THAT ARE SIMILAR TO BUIDINGS SHALL BE SELECTED IN ACCORDANCE WITH SECTION
12.6. THUS, AS PER ASCE 7-10 SEC. 12.6, THE EQUIVALENT LATERAL FORCE PROCEDURE WILL BE USED.
SEISMIC CRITERIA:
1.463 Seismic Coefficient Fa :=1 Site Amplification Factor
Si := 0.546 Seismic Coefficient Height of Structure In Feet (Unitless)
n ft
S = 0.975 Seismic Coefficient c, 0.02 Approximate Period Parameter 1 (Table 12.8-2)
SDI := 0.546 Seismic Coefficient x:= 0.75 Approximate Period Parameter 2 (Table 12.8-2)
T,6 Long -Period Transition
DESIGN CRITERIA:
ft2
Total Area of Roof
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK ?TT GROVE
ENGINEERING
2 (Width + Length) = 29 ft
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
Total Length of Walls
LATERAL FORCE GENERATION (SHEAR WALL):
( Wt :1.-- (A,(4 • DLIi) + ----2 • Ldi • DLpf) =845.32 ibf Effective Seismic Weight
T „:= t • ta„' =7-0.1
Approximate Fundamental Period
NOTE: IF THE STRUCTURE IS 5 STORIES OR LESS ABOVE THE BASE, Ss MAY BE RECALCULATED AS:
S,:= if (Ta 0.5,min (1.5 , ,S) = 1.463 Seismic Coefficient (12.8.1.3)
2
Sac :=—• F • S, 0.975
3
SOS
R.
Theoretical Site Coefficient
=0.39 Seismic Response Coefficient (Sec. 12.8.1.1)
C.4_7114.1" if
SDI SDI`TL
„
R) 2 IR)
T • (— T •
I, a
=2.194 Maximum Coefficient
:= max (0.044 • S Ds • , 0.01) = 0.043
0.5•Si
if Si > 0.6, ....._R ,C„
ji
(I,
max (C, , ) = 0„39
Cs= rain (C; , , C.' ) = 0.39
Minimum Coefficient
=0.043 Minimum Coefficient
Seismic Response Coefficient
Seismic Response Coefficient
Fi,:=C,• WI= 329.79 lbf Seismic Base Shear
ASD Seismic Base Shear
F p „.„I:= 0.7 • Fp= 230.85 lbf
Fp_i„„,„„„ 1:= — • Length. • pi„„,„,1= 171.7 ibf Lateral Force from Minimum Indoor Lateral Load (1-1)
- 2
Fd(
„g„_, := max (FdiFp_prcvreire_l = 2:30.85 lbf Lateral Design Force (1-1)
lErfr.s-vg,1_
= 98.57 74
Lengt/L
F p_pres.4tfre_.2
2
Distributed Design Load (1-1)
• 1Vidth • p„a„,„,1= 136.43 ibf Lateral Force from Minimum Indoor Lateral Load (2-2)
Fp_firmgit_2'="18'x (F1,_ageill:Pp_prc.w%frt._1) = 230.85 ibf Lateral Design Force (2-2)
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK IT GROVE
N G.NEER IN
Fp cfct 2
Wricrugu 2 Width := r
- Pi/
SHEAR WALL CALCULATIONS:
L=6.422 ft
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
Distributed Design Load (2-2)
Length of Wall Line 1 T„o := 4.04 ft Tributary Width
•
15.79 plf in -Plane Force on Wall 1
L2:= Width = 6.42 ft Length of Wall Line 2 Ttmith 2 := 4A/4. ft Tributary Width
2 wat,orm_i • Twidtit_2 15 . 79 Of
:=
L2
77Lin(L1, 2
160 Of
In -Plane Force on Wall 2
=1.3 Worst Case Shape Ratio
CHECK: Frin_r„piam,> nia.x (fi f ,)=1
LA := 8.08 ft
_ wde,Ig44_2 •1 wi
A
LA
LR:=:3 ft
Allowable In -Plane Shear (LARR 25690)
Length of Wall Line A T„,idth_A :=3.21 ft TributaryWidth
= 12.55 plf
In -Plane Force on Wall A
Length of Wall Line B T:1urith13:= 3.21 ft Tributary Width
fitod,,5illv_2 • Tividrit_n _ 33.7, pif
t '=
1/444
R. = 2.7
min (LA , .L)
Full tuplaue::"2- 77 pif
CHECK: F,in4?, max
fA, =1
In -Plane Force on Wall B
Worst Case Shape Ratio
Allowable In -Plane Shear (LARR 25690)
SUMMARY: THERFORE_USE5 THICK WOOD FRAMED URETHANE FOAM PANELS FOR LAURA/.
RESISTANCE,
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK tr GROVE
EN G EERING
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
6) TYPICAL CEILING TO ALL CONNECTION (DETAIL 2)
H „,= 8.08 ft
LOADS:
1111
Ptrarrs' := Pt?! tri-rtal::: 20.21 Of
2
fir,.14„,,:= max
f1 f 21[13.f13 = 33.79 Of
fmax :=1-11" (pram.. finpinrp.r) = 33.79 Plf
LAG SCREW CONNECTION:
23 in
11.4111....,r-F.F.u, •
573 ibf — 298.96 of
Smcrrri,
Design Height
Out -Of -Plane Shear Force on Connection
In -Plane Shear Force on Ceiling -Wall Connection
Maximum Shear Force on Anchor
Spacing of Connection Through Angle
Allowable Shear of Lag Screw (LARR 25690)
CHECK: f nuix ail scum = 1
SUMMARY.. THE IMPOSED FORCE ON THE CONNECTION IS LESS THAN THE ALLOWABLE FORCE.
THEREFORE. THE WALL -CEILING CONNECTION IS ACCEPTABLE FOR RESISTING DESIGN
LOADS,
7 WALL TO CONCRETE CONNECTIONS DETAIL 3
11„,= 8.08 ft
LOADS:
Ptrams 2 = 20 .21 Of
.f max f f A f rs) =_ 3:3 79
f Mai
Ptrart.N f plow) = 33.79 Of
#14 TEK SCREW:
5,,,„,„,11:= 23 in
CD:= 1.6
CD• 142 ibf
Van Ncruu.,14'• — 118.54 Of
CD • 172 ibf
Taii_,SCrcto1•1:= s:-- 143.58 plf
scret4,14
Design Height
Out -Of -Plane Shear Force on Connection
In -Plane Shear Force on Floor -Concrete Connection
Maximum Shear Force on Anchor
Spacing of #14 Tek Screw Through Angle
Load Duration Factor (2015 NDS)
Allowable Shear of #14 Tek
(Dowel Bearing Strength In Design Aids)
Allowable Tension of #14 Tek (2015 NDS)
812 S. La Cassia Dr. • Boise, Idaho 83705 (208) 345-8941 (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK 11 GRO
ENO`NEERING
16-GA ANGLE BEARING STRENGTH (AISC SECTION J3.10):
d := 0.25 in Diameter of Screw
t := 0.060 in Thickness of Angle
0=0.75 LRFD Factor
fl
:= 1.2 /,. • t • F„, 3042 lbf
min
23 in
fl
,R„ 404 ibf
fina:r
Rt„i„:= =93 ibf
0.7
HILTI KH-EZ:
24 in
r : 1 in
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
d 0.125 in
0.B1 in Clear Edge Distance
2
52 kon Tensile Strength of Angle
R „2:= 2.4 d • t • F„. 1872 lbf
Bearing Capacity
Spacing of Anchor
LRFD Shear Force on Anchor
Spacing of Anchor Through Angle
„:= 2.0 Overstrength Factor
11“•
mycluor:=
11111-r 4911110i4J/
19 3 1 1 lbf
0.7
750 lbf
CHECK V„ii.,..wrovti finpium:
Vnanriwr> V gnehor =
1
Shear Force on Anchor
Allowable Shear on Anchor (Hilti Anchor
Software Printouts)
Mattis 1
R,› Rua = 1
SUMMARY: THE IMPOSED FO10E CN THE CONNEC77ON IS LESS THAN THE ALLOWABLE FORCE.
LOADS,
812 S. La Cassia Dr. • Boise, Idaho 83705 (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
Project Name:
Location:
f GROVE TGE Job
TRAPPER SUSHI
TUKWILA, WA
Number: TGE19-12562
TAMARACK
ENGINEERING
8
8.1
SOFTWARE PRINTOUTS
HILTI PRINTOUTS
www.hiltt.us
Profis Anchor 2.7,1
Company: TGE
Specifier:
Address,
Phone 1 Fax: I
E-Mail:
Page: 1
Project: Trapper Sushi
Sub.Project 1 Pos. No.:
Date: 5/22/2019
Specifiers comments:
1 Input data
Anchor type and diameter:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof.
Stand-off installation:
Anchor plate.
Profile:
Base material:
Installation:
Reinforcement:
Seismic loads (cat C, D, E, or F)
Geometry [in,] & Loading [lb, in.Ib]
1.
KWIK HUS-EZ (KH-EZ) 1/4 (1
tioc,„ = 1.180 in., h,,,,m = 1.625 in.
Carbon Steel
ESR-30.27
2/1/2016 112/1/2017
Design method ACI 318-14 / Mech.
et, = 0.000 in. (no stand-off); t =
I,, x I., x t = 1.500 in. x 24.000 in.
no profile
cracked concrete, 2500, fi = 2500
hammer drilled hole, Installation
tension: condition B, shear: condition
edge reinforcement: none or <
Tension load: yes (17.2.3.4 3 (c))
Shear load: yes (17.2.3.5.3 (b))
Z
5/8)
4
0.060 in.
x 0.060 in.; (Recommended plate thickness. not calculated
psi; h = 4.000 in.
condition: Dry
B; no supplemental splitting reinforcement present
No. 4 bar
X
Input dela end results r,Wst be Checked for agreement usth Ihs exreling cond/tions and for plusib. 1yl
PROFIS An ( c) 2003-2009 Hall AG, FL-9494 Sctw3n H=Si a n registamd Trams+nark of HOD AG, Srnaan
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
Project Name:
Location:
TRAPPER SUSHI
TUKWILA, WA
Number: TGE19-12562
TAMARACK IT GROVE TGE Job
ENG.NEERING
www.hlltl.us
Profis Anchor 2.7.1
Company: TGE Page: 2
Specifier: Project: Trapper Sushi
Address: Sub -Project I Pos, No.:
Phone I Fax: I Dale: 5/2212019
E-Mail:
2 Load case/Resulting anchor forces
Load case: Design loads
Anchor reactions [lb]
Tension force: (+Tension, -Comprasson)
Anchor Tension force Shear force Shear force x Shear force y
= NJ.
1 0 750 0 750
max. concrete compressive strain: • Nil
max. concrete compressive stress: • [Psi]
resulting tension force in (x/y).(0.000/0_000): 0 [lb)
resulting compression force in (x/y)=-(0.000/0.000): 0 [Ib)
3 Tension load
Load N„. [Ib] Capacity • N,, [Ib] Utilization pN
Nn Status
Steel StrengthN/A N/A N/A N/A
Pullout Strength' N/A NIA N/A N/A
Concrete Breakout Strength" N/A N/A NIA NIA
' anchor having the highest loading "anchor group (anchors in tension)
1,,,,„j gala oeivd ',mutts rmOi be 04Kkges for pgreemmn( mfh the eltisung CCIfIthiions and for plat+34.11YI
PROFIS Anchor ( c i 2003-2009 HMI AG. FL-949e Schwan H0i is a registered Trees...nark or i-litti AG. Scr-aan
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
• STRUCTURAL ENGINEERING
CALCULATIONS
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TAMARACK Tr GROVE TGE Job Number: TGE19-12562
ENGINEERING
%WOW. hilti.us Profis Anchor 2.7.1
Company: TGE Page:
Specifier: Project: Trapper Sushi
Address: Sub.Project I Pos. No.:
Phone I Fax: Date: 5/22/2019
E-Mail:
4 Shear load .
Load Vue (lb) Capacity +V, (lb) Utilization (3v = V„). V, Status
Steel Strength750 836 90 OK
Steel failure (with lever arm) NIA N/A NIA N/A
Pryout Strength** 750 763 99 OK
Concrete edge failure in direction '• N/A NIA NIA N/A
' anchor having The higheS1 loading —anchor group (relevant anchors)
4.1 Steel Strength
V„.„ = ESR value refer to ICC•ES ESR•3027
Vo,..9, a VACI 318-14 Table 17.3.1.1
Variables
N.,,, tin-1 f. [Psi)
0.05 134000
Calculations
V..„ [lb]
1393
Results
V5a e„, (lb] 4) .e.,1 4) rooduct/le ,I) V„ [lb] Vi,a [lb]
1393 0.600
4.2 Pryout Strength
V, = k‘p RAT0A ,N r.,N ,I, 44-1N
V„ a Vua
AN, see ACI 318-14, Section 17,4.2,1,
ANc0 ' 9 fl:r
1
1.000 836 750
ACI 318-14 Eq. (17,5,3.1a)
AC1 318-14 Table 17.3.1.1
Fig. R 17.4.2.1(b)
ACI 318-14 Eq. (17.4,2,1c)
iii .,,ry =
= 0.7
(1 + 2 el., ) 5 1.0 ACI 318-14 Eq. (17,4.2,4)
3 ho
+ 0.3 5 1.0 ACI 318-14 Eq.
(17.4.2.5b)
ic'rti r)
„
= MAX(—c, i 5h,r6—, --.) 5 1 0 ACI 318-14 Eq. 4 2,7b)
kr cp,N (17
c. CItc
fqb , kc A. , NI, h:45 ACI 318-14 Eq. (17.4,2.2a)
Variables
lc, ho (in.] ecl.N lir1-1 ea.N Iin-i co,r„„ tin.]
1 1,180 0.000 0.000 .,
Y ..•1 c,, [in.] k ., fc [psi]
1.000 2.000 17 1.000 2500
Calculations
AN (in.21 A, [in.2] 'V el: i N Y gc2,tf Y Nt, [lb]
12.53 .53- 1.000 1.000 1.000 1'.00 1090
Results
V, [Ib) + r.iwi-,iiii. 4 “,,,,,,, el) nonchicyla 0, V. [lb] V. [lb)
1090 0.700 1.000 1.000 763 750
Input di4i *,d r.S.AIS r.,bl br d,eckal r9, agreernant 1.1h the existing mictOrtions and for dlausittgleyt
PROFIS Ancrtior (c i 2003-2009 Htiti AG, FL-9494 Sthaan Hire rg a registered Trademark of Hilt AG. Schwan
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
wvvvv.hiltlus
TAMARACK P GRO
ENG,NEERiNG
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGEI9-12562
Profis Anchor 2.7,1
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
TGE
Page:
Project:
Sub -Project I Pos. No.:
Date:
4
Trapper Sushi
5/2212019
5 Warnings
• Load re -distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. The (1) factor is increased for non -steel Design Strengths except Pullout Strength
and Pryout strength. Condition 8 applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to
your local standard.
• Refer to the manufacturers product literature for cleaning and installation instructions.
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard!
• An anchor design approach for structures assigned to Seismic Design Category C. D, E or F is given in ACI 318-14. Chapter 17, Section
17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the
case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or -Section 17.2.3.4.3 (d). The
connection design (shear) shall satisfy the provisions of Section 17.2.3.5,3 (a), Section 17.2.3.5.3 (b), or Section 172.3,5.3 (c).
• Hilti post -installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPH). Reference ACI
319-14, Section 17 8 1
Fastening meets the design criteria!
input data and maids roust bc checked idc aorceinerd odhih'Oda's; cdnadions and for pIadsdaidyl
PROFIS Ana.). c I 2003-2009 Hi AG, F1,9494 Schaan Hi is a registered Tredeioark of Hilt AG, Saloon
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
s
TAMARACK tr GROVE
ENGINEERING
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
Profis Anchor 2.7.1
Company:
Specifier:
Address:
Phone 1 Fax:
E-Mail:
TGE
Page:
Project:
Sub -Project I Pos. No.:
Date:
Trapper Sushi
5/22J2019
6 Installation data
Anchor plate, steel. -
Profile: no profile
Hole diameter in the fixture: cl, = 0,375 in,
Plate thickness (input): 0 060 in.
Recommended plate thickness: not calculated
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according
6.1 Recommended accessories
Drilling
Anchor type and diameter KWIK HUS-EZ (KH-EZ) 1/4 (1 518)
Installation torque: 216.002 in.lb
Hole diameter in the base material: 0.253 in.
Hole depth in the base material: 1,836 in,
Minimum thicknoss of the base material: 3.250 in,
to instructions for use is required_
Cleaning
Setting
• Suitable Rotary Hammer • Manual blow-out pump
• Properly sized drill bit
Coordinates Anchor in.
Anchor x
1 0.000 0.000
c. c.„
c•y
•
0 0
0 0
0 0
csl
0
02E17E0
•
0
0
0
x
• Torque wrench
Input data and reevesnw1 he checked kat agreemen1 oath Ihr ecisling concldion% and Far platmlaiMil
PROF IS Anchor c 2003-21349 Hdli AG. FL-9-49e Schean Rch 19 a registered Trademark of Hilk AG. Schaan
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK r GROVE
E N G NEER i
9 MATERIAL AND HARDWARE PRINTOUTS
9.1 CUSTOM COOLER LARR 25690
BOARD OF
BUILDING AND SAFETY
COMMISSIONERS
VAN AMBATIELOS
PFtEcoChfT
E. FELICIA BRANNON
VICE PRESIDENT
JOSELYN GEAGA•ROSENTHAL
GEORGE HOVAGUIMIAN
JAVIER NUNEZ
CITY OF Los ANGELES
CALIFORNIA
ERIC GARCETTI
MAYOR
CC! Global LLC. DBA Custom Cooler
A KPS Global Company
420 East Arrow Ilwy
San Dimas. CA 91773
Attn: Stcvc Pearson
(909) 592-1111
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
OP•ARTMENT OF
BUILDING AND SAFETY
I NORT-1 FIGUEROA STREET
LOS AtiGELCS CASCO' 2
FRANK M. BUSH
GENtRAL MANAGER
SUPERREFTNDENT OF MADING
OSAMA YOUNAN. P.E.
EXEWTIVE OFFICER
RESEARCH REPORT: RR 25690
(CSI tt13030)
E.Npires December I. 2020
Issued Date: February I, 2019'
Code: 2017 LABC
GENERAL APPROVAL — Clerical .Modification - Custom Cooler Incorporated Prefabricated
Model 300 Refrigeration Panels for Walk -In Coolers and Freezers.
DETAILS
The panels consist of 34/2" to 5-1/2" thick high density foam or wooden frames with tnamed-in-
place rigid plastic core material tnanufactured by Dow Chemical. Company and designated as:
Voracor CE108, CEI51, CE153,CE128, CE155,CE152,CE157 "A" side.
Delta Therm AF4509 or Voracor CR 1004 "B" side:
llie skins are fabricated from. 26 gauge galvanized steel with a minimum yield strength. 33 ksi,
The panels are held together by the usc of earn -locking devises along thc edges of the panels.
Access holes for these devices are covered with metal or plastic plugs. Flame Spread and Smoke
Development ratings per ASTIYI E84 are 20 and 300 respectively. for the foam (tested alone) and
15 and 250 respectively, for the foam with the skin described below. Density of the foam core is
2,2 ± or -.2 pct..
Custom Cooler incorporated freestanding walk-in coolers and freezers constructed of
panels described above are approved subject to the following conditions:
Use of the panels shall be limited to locations where combustible construction is
permitted by the 2017 Los Angeles City Building Code,
The panels shall be fabricated in a shop of a licensed fabricator approved by thc Los
Angeles City Building & Safety Department, Fabrication in unlicensed shops will
invalidate this approval.
RR 25690
Page 1 of 5
t ADSS D.A ;Ft....04:30r2014) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER
812 S. La Cassia Dr. Boise, Idaho 83705 • (208) 345-8941 (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
ENGINEERING
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
CO Global LLC, DBA C'ustorn Cooler a KPS Global Company
Re: Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers
and Freezers
3. A thermal barrier is required per Section 2603.4 of the 2017 Los Angeles City Building
Code unless exempted per Section 2603.4.1.
4. Complete plans and calculations, signed and stamped by a civil or structural engineer or
architect registered in the State of California, shall be submitted to the Structural Plan
Check for their approval. for each job.
5. An approved fire retardant roof covering (Class "A" or "B") shall be placed over the
panels when used as exterior roof panels,
6. A separate approval from the Electrical Testing Laboratory shall be required for electrical
installations within the panels.
7. Design of building utilizing the panels shall be in accordance with the requirements of the
2017 Los Angeles City Building Code and the design data specified
A. Panel fleiuht Limitation (feet) and Maximum Concentric Axial Loads (PLF)
Thickness
Interior Panels
Exterior Panels
(20 11)/sqft)
Maximum Axial
Load (PLO
4" wood Frame
30
IX
600
4" foam Frame
24
13
300
5'' wood Frame
31
20
600
5"foam Frame
28
14
300
6" wood Frame
32
21
600
6" foam Frame
30
15
300
RR 25690
Page 2 of 5
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK GRO
ENG'NE E RING
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
CCI Global LLC, DBA Custom Cooler a KPS Global Company
Re: Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers
and Freezers
B, Maximum Allowable Loads for Roof or Ceiling Panels
(
---
Span
t - 4 in. W/F
t = 4 in. F/F
t = 5 in. W/F
t=5 in, F/F
t • 6 in. W/F
t — 6 in. Fir
10'
53
49
65
65
79
79
12
50
36
55
48
6(i
62
14'
37
27
47
37
57
48
16'
28
20
40
29
50
38
18'
22
16
32
23
42
30
20'
18
13
25
18
34
24
22'
14
10
20
15
27
20
24'
11
8
17
12
23
16
26'
9
7
14
10
19
13
28'
8
6
11
8
16
11
30'
6
-
10
7
13
10
32'
- .
-
9
6
11
8
Maximum Allowable Shear oad of Wall Panels (PLF):
'hap (lleight:Width) Ratio
Allowable Shear (ppf)
0,5:1
400
1:1
200
1.5:1
133
2:1
100
D. Maximum Allowable Rouc/Ce1Iin1 Diaphragm Shear
'hat' Fctr (Heiglit: Width) Itatio
Allowable Shear (ppf)
0,5:1
400
1:1
200
1.5:1
133
2:1
100
3:1 MANIN1Uls.1
67
RR 25690
Page 3 of 5
812 S. La Cassia Dr. • Boise, Idaho 83705 (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK T GROVE
ENG.NEER iNG
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
CC1 Global LLC, DBA Custom Cooler a KPS Global Company
Re: Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers
and Freezers
The panels shall be continuous between exterior shear walls and shall not contain any openings
or holes.
E. Ceiling panel to wall panel connections arc made with 3/8" dia. Lag screws or cam -
locking devises, then a 26 gauge galvanized continuance angle cap is installed using #8 x
5/8" long tek screws (see attachment I ). The allowable shear and tension loads for the lag
boll connection are 573 and 472 pounds respectively. The allowable shear and tension
loads for the camlock connection are 464 and 123 pounds respectively,
E. Maximum Allowable Loading for the Cam-LockingDevices:
Wood Frame
Foam Frame
Tension parallel to panel face
386
168
Shear along longitudinal edge of panel in
direction parallel to panel edge
280
147
Locations of connectors must be detailed on approved plans, the spacing of connections
shall be calculated for each job but not less than 6,vo per width of panel (Wdth of panel =
46 1/2").
9. Allowable loads for shear walls and diaphragms are not applicable to buildings
incorporating structural steel framing.
10, No increase in allowable stresses is allowed for the values indicated above for short
duration of loads due to wind or seismic forces,
11. All design values and methods not included in this report shall be in accordance with
requirements of the 2017 Angeles City Building Code.
DISCUSSION
The clerical modification s to recognize a new petitioner for this general approval.
The report is in compliance with the 2017 Los Angeles City Building Code,
The approval is based on tests on the foam per requirements of See, 2603 of the 2017 Los
Angeles City Building Code, tests conducted in accordance with ASIM E-g4 on the finished
panels. and load tests conducted in accordance with ASTM E-72.
Addressee to whom this Research Report is issued is responsible for providing copies of it.
complete with any attachments indicated. to architects, engineers and builders using items
approved herein in design or construction which must be approved by Department of Building
and Safety Engineers: and Inspectors.
RR 25690
Page 4 of 5
812 S. La Cassia Dr. • Boise, Idaho 83705 (208) 345-8941 • (208) 345-8946 FAX
STRUCTURAL ENGINEERING
CALCULATIONS
TAMARACK 11 GROVE
E N G , N E E R 1 N G
Project Name: TRAPPER SUSHI
Location: TUKWILA, WA
TGE Job Number: TGE19-12562
CCl Global LLC, DIM Custom Cooler a KPS Global Company
Re: Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers
and Freezers
This general approval of an equivalent alternate to the Code is only valid where an engineer
and/or inspector of this Department has determined that all conditions of this Approval have
been met in the project in which it is to he used.
DAVID CHANG, Chief
Engineering Research Section
201 N. Figueroa St., Roorn 880
Los Angeles, CA 90012
Phone-213-2(12-9816
Fax- 213-202-9943
Attachment: Panel Connection Detail (2 Pages).
RR 25690
Page 5 of 5
812 S. La Cassia Dr. • Boise, Idaho 83705 • (208) 345-8941 (208) 345-8946 FAX
PTN050H6AE - SUBMITTAL
C1 For Record
C1 For Approval
Project Name:
018-6287
Project Location:
US, WA, Tukwila
Quote-Veision #:
R426666-1
Item #:
1000
Submitted For
Elsa flora
Submitted On:
2019104/24
Submitted By:
Rick Jones
Submitted From:
Custom Cooler
Identity #:
Tag:
By: D te:
General Product Information
Product Family:
PTN
Voltage: (Volts/Ph/Hz)
115/1/60
Application:
Indoor
Refrigerant Type:
R404A
Temperature Range:
High Temp
Unit Cooler Motor Type:
EC
Defrost Type:
Air
Compressor Model:
RST45C1E
Technical Information
Capacity
Ambient Temp
(7)
95
Room Temp
(°F)
35
Capacity
(BTU/H)
5,120
Electrical Data
MCA
MOPD
Unit Amps
14
20
11,6
Unit Specifications
Plug Supplied?
Matching NEMA
Receptacle
Number
Approx. Net,Weight
(lbs)
YES
5 2OR
192
Dimensional Drawing(s)
24 3/4
51 3/8
4
AIR FLOW
UOM: inches
28 9/16
24 3/4
—ELECTRICAL CONNECTION
AGENCY LISTINGS
0 US
Page 3 of 4
PTN050H6AE - SUBMITTAL
Project Name:
018.6287
Project Location:
US, WA, Tukwila
Quote -Version #:
R426666-1
Item #:
1000
Submitted For.
Elsa Boza
Submitted On:
2019/0424
Submitted By:
Rick Jones
Submitted From:
Custom Cooler
Identity #:
Tag:
Standard Features
EASE OF INSTALLATION & SERVICE
INSTALLATION TAKES A FRACTION OF THE TIME REQUIRED FOR A SPLIT
SYSTEM: NO PIPING OR LOOSE COMPONENTS TO INSTALL, REFRIGERANT IS
PRE -CHARGED AT FACTORY AND A FIELD SUPERHEAT ADJUSTMENT IS NOT
REQUIRED (SEE INSTALLATION MANUAL FOR MORE INFORMATION)
MAXIMIZES STORAGE AREA IN A COOLER OR FREEZER: EVAPORATOR GRILL
MOUNTS FLUSH ON A STANDARD 4 OR A RECESSED 5 1/2 CEILING PANEL
NO DRAIN LINE REQUIRED ON INDOOR MODELS - COME STANDARD WITH A
CONDENSATE EVAPORATION PAN
OPTIMIZED FOR INDOOR USE.
ENERGY EFFICIENT AND ENVIRONMENTALLY FRIENDLY
REDUCED REFRIGERANT CHARGE: SYSTEM USES APPROXIMATELY 10 PERCENT
OF REFRIGERANT REQUIRED FORA COMPARABLE SPLIT SYSTEM. RESULTS
MAY VARY. ESTIMATES BASED ON A TYPICAL 25-FOOT REFRIGERANT LINE
LENGTH,
EASE OF USE
CONTROLS PRESET FOR TYPICAL APPLICATIONS:.38 F FOR HIGH TEMP.
COOLERS, t35 F FOR MEDIUM TEMP, COOLERS, -10 F FOR FREEZERS AND ARE
EASY TO ADJUST
SYSTEM IS FACTORY -ASSEMBLED, EVACUATED, CHARGED, RUN -TESTED AND
WIRED: NO ADDITIONAL COMPONENTS OR REFRIGERANT CHARGING REQUIRED
REUABLE & DURABLE
ELECTRONIC CONTROL PROVIDES ACCURATE TEMPERATURE CONTROL
LIQUID -LINE FILTER DRIER (MEDIUM AND LARGE CABINET ONLY)
TWO-YEAR PARTS WARRANTY
Options
Shipped -Loose Options (Unit)
(QTY)Pert Number- Description
WARCHO-3 - PRO3 1/2-1 HP HERMETIC WARRANTY (3YR)
Evaporator
Section
w compress
Min. on
Evaporate
Airflow
Top View
u— �i►
2 x Width
Min.
Evaporator
Section
Compressor
Section
Evaporate
Airflow
Side View
(QTY)Pert Number- Desalplion
Airflow
Minimum 2"clearance
Allow 2 feet clearance above
unit to remove top panel
and to allow service access.
Mounting rails may be used
to attach unit to ceiling.
Through -bolts should be
insulated or non-conductive
to prevent sweating.
Page 4 of 4
City of Tukwila
Department of Community Development
12/3/2019
GARRY BELCHER
7907 212TH ST SW #100
EDMONDS, WA 98026
RE: Permit No. M19-01 12
TRAPPER'S SUSHI
468 SOUTHCENTER MALL
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such perrnit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 1/21/2020.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 1/21/2020, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: MI9-0112
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M19-0112
PROJECT NAME: TRAPPER'S SUSHI
SITE ADDRESS: 468 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
DATE: 07/10/19
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
LOC
Building Division
Division
Public Works
LI
M 161\10
Fire Prevention
Structural
Planning Division
Permit Coordinator pp
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 07/11/19
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
n
(corrections entered in Reviews)
DUE DATE:: 08/08/19
Approved with Conditions
Denied
(ie: Zoning Issues
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW El Staff Initials:
12/18/2013
POLAR BEAR MECHANICAL It
Page 1 of 2
Home Esrpafiol Contact
Safety & Health Claims & Insurance
Washington State Department of
Labor & Industries
!Search L&I kit:t.t$,A
A-4 111(it`X Help Mv 1.&I
Workplace Rights Trades & Licensing
POLAR BEAR MECHANICAL INC
Owner or tradesperson
Principals
BELCHER, GARRY DEWAYNE, PRESIDENT
Doing business as
POLAR BEAR MECHANICAL INC
WA UBI No.
603 145 986
Certifications & Endorsements
401 NE RAVENNA BLVD 130
SEATTLE, WA 98115
425-967-5827
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
POLARBM891PC
Effective — expiration
10/03/2011— 10/03/2019
Bond
Western Surety Co
Bond account no.
62501547
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
10/09/2015 09/12/2015
Expiration date
Until Canceled
Bond history
Insurance
Peleus Insurance Company $1,000,000.00
Policy no.
103GL0024783-00
Received by L&I Effective date
08/07/2018 08/01/2018
Expiration date
08/01/2019
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
Help us improve
TUT-4(111 A COQK TC=DC1T A D1:211.4 40 1 Dr 2,c A IV= -7/')GrM10