Permit M19-0131 - EDWARD JONES - NEW VAV BOX AND MODIFY DUCTWORK
EDWARD JONES 6840 FORT DENT WAY M19-0131 C) Parcel No: ��^�x» °�� Tukwila *°�~n x�n n ��m"w��na Department of Community Development G3VVSuuthcenterBoulevard, Suite #10V Tukwila, Washington S8188 Phone:JO6'431'367O Inspection Request Line: 3V6'43B'935D Web site: http://www.TukwilaWA.gov 2954900425 6840 FORT DENT WAY Project Name: EDWARD JONES MECHANICAL PERMIT Permit Number: K819'0131 Issue Date: 8/15/2019 Permit Expires On: 2/11/2020 Owner: Name: Address: Contact Person: Name: Contractor: License No: Lender: Name: ]OH0[RADOV[HDEVCO Z83S82NDAVSE#S-1'MERCER ISLAND, WA, 98040 JOHNyNERR|LL Phone: (253)831-4440 642618THST[, FIFE, WA, 98406 MECHANICAL & CONTROL SRVC5INC Phone: (253)926'9777 (GENERAL) 6426 18THSTE.FIFE, VVA,984Z4 KxE[HAC59628T Expiration Date: 2/26/2020 ''' DESCRIPTION OF WORK: INSTALL (1) NEW VAV BOX. MODIFY DUCTWORK FOR NEW FLOOR PLAN LAYOUT. Valuation of Work: $12,000.00 Type ofWork: NEW Fuel type: ELECT Fees Collected: $357/41 Electrical Service Provided by: Water DistriSewer District: TUKWILA ct: PUGETSOUND ENERGY TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA State Energy Code: VVACities Electrical Code:2017 VVAC296-4613: 2017 2017 Date:O-/5-1^� ' | hearbycertify that | have read and examined this permit and know the same to betrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state o/local laws regulating construction orthe performance ofwork. |amauthorized tnsign and obtain this development permit and agree to the conditions attached to this permit. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended orabandoned for aperiod uf18Odays from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based nnsatisfactory completion ofthis requirement. G: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (ZO5-43l'367O). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center, 7: VALIDITY DFPERMIT: The issuance orgranting ofapermit shall not beconstrued tobeapermit for, oran approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not be valid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: `MECHANICAL PERMIT COND0UNS~~+ 9: All mechanical work shall beinspected and approved under aseparate permit issued bythe City cfTukwila Permit Center (2O6/431'367O). lO: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWIP Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http ://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: 9-""19 y Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 295490-0425 Site Address: 6840 FORT DENT WAY TUKWILA, WA Suite Number: 2 3 0 Floor: 2 Tenant Name: EDWARD JONES New Tenant: [V] Yes 11..No PROPERTY OWNER Name: John C. Radovich Dev. Co. Address, 2835 82nd Ave. SE City: Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: JOHN MERRILL Address 6426 18th St. E City: FIFE State: WA Zip: 98424 Phone: (253) 831-4446 Fax: (253) 926-9222 Email: JOHNM@GROUPMCS.COM MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services Address: 6426 18th St. E City: FIFE State: WA Zip: 98424 Phone: (253) 926-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS962BT Exp Date: 01/30/2020 Tukwila Business License No.: 0997334 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: INSTALL (1) NEW VAV BOXE. MODIFY DUCTWORK TO ACCOMMODATE NEW FLOOR LAYOUT. 12,000 Use: Residential: New LI Replacement El Commercial: New Replacement 'El Fuel Type: Electric 61 Gas LI Other: WiApplicationsWorms-Applications On Line\ 2016 ApplicationsWeehanical Permit Application Revised I-4-16.docx Rr.vies.,1• 1111 A 1 nf Indicate type of mechanical work being installed and the quantity below: ' . Unit ype Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling _ystem Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial „._ Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and SAM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 07/31/2019 Print Name: J°11N MERRILL Day Telephone: (253) 831-4446 Mailing Address: 6426 18TH ST. E FIFE WA 98424 City Zip State 14AApplicationsWorms-Applications On Line \ 2016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 Cash Register Receipt city of Tukwila Receipt Number ' DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY r ,,i PAID ., $436.24 EL19-0629 Address: 6840 FORT DENT WAY Apn: 2954900425 $78.83 ELECTRICAL $75.08 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $75.08 TECHNOLOGY FEE $3.75 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.75 M19-0131 Address: 6840 FORT DENT WAY Apn: 2954900425 $357.41 MECHANICAL $343.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33,15 PERMIT FEE R000.322.100.00.00 0.00 $241,78 PLAN CHECK FEE R000.322.102,00.00 0.00 $68.73 TECHNOLOGY FEE $13.75 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18275 R000.322.900.04.00 0.00 ,:. $13.75 $436.24 Date Paid: Tuesday, August 06, 2019 Paid By: MECHANICAL & CONTROL SERVICES Pay Method: CHECK 30489 Printed: Tuesday, August 06, 2019 1:41 PM 1 of 1 CAW YS TE M S INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Type of Ins Afia-44•41/C4-1-- on: ssAkfle----- Add ess; Date Callled: Spec p lnstruc o�ons: Date Wanted: a.m.. ---� ~-E p.m. Requester: ini 1 IyG{-+A Phone hl©: c q 7 toe6 7 t4Approved per applicable codes. Corrections required prior to approval. COMMENT nspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ec : Tyr •€ ifnsp tici�r' ii .xri . .....». .._l. _ _ i .. ,. 1 Address: 6Pio 1� Date Ca11 Special Instructions: 'Date Wanted: "'" z-S -- 2a9 a.m. p.m. Requester: Phone Mo: .''063 Appfoved per applicable codes. COMMENTS: Corrections required prior to approval. Inspecto Date: REINSPECTION FEE REQUIRED. Prior to next in pection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. VAV Fan Powered Terminal Units Job Information TRAM' Edward Jones Tukwila Seattle Main Office (B31)Michael Woods FILE Tag Model Number Quantity Unit Information Unit model Trane supplied controls Unit insulation Elevation Design cooling airflow Min cooling airflow Heating Information VAV-8" VSEF08 1 Primary inlet Fan size VSEF (Series Fan Electric Heat) Refer to "Customer Supplied" controls 1" matte faced 0.00 ft 600 cfm 110 cfm Unit heating airflow Valve heating airflow Unit LAT Primary EDB Plenum EAT Coil EAT Coil LAT Coil heating capacity Room heat loss APD @ cooling airflow Cooling inlet diameter Cooling inlet velocity Operating weight Max inlet SP 8" (203mm) 03SQ 0.230 in H20 8.000 In 1719 ft/min 106.0 Ib 0.750 in H20 930 cfm 165 cfm 75.80 F 55.00 F 70.00 F 67.34 F 75.80 F 8.54 MBh 7.87 MBh Fan/Electrical Information Motor voltage Downstream SP Fan airflow Motor type 277 0.300 in H20 930 cfm High efficiency ECM % of fan range 78.00 % Acoustical Performance Octave Band Discharge, fan Radiated, fan Radiated, fan and valve 125 Hz 72 dB 65 dB 68 dB 250 Hz 63 dB 62 dB 64 dB Room heating setpoint Hot water coil Electric heater kilowatt Electric heater voltage Electric heater stages Coil fluid PD Fluid type Fluid concentration Heating Cv Fan TSP Fan power Full load amps Min circuit ampacity Max overcurrent protection 500 Hz 1 kHz 64 dB 62 dB 61 dB 59 dB 62 dB 60 dB Sound power level in dB re 1 pW. Acoustical data obtained in accordance with AHRI 880-11. Noise criteria (NC) estimate is calculated using the following transfer function: Discharge Radiated AHRI 885-98/08 AHRI 885-98/08 Mineral Fiber The AHRI 885 -98 transfer functions are the same as AHRI 885 -oa 7/17/2019 Product Version 5,00 ot 68.00 F No hot water coil 2REVIEWED FOR CODE COMPLIANCE , APPROVED AU6 0 8 2019 CitTotThicwila BIAILPING DIVISION Q.333 hp 11.43 A /4.28 A /5.00 A 2 kHz 58 dB 56 dB 57 dB 4 kHz 57 dB 56 dB 58 dB NC 24 36 37 IIECEIVED CITY OF TUKWILA AUS 06 2019 PERMIT CaiiliER Edwant AanmTubsia MANE' VAV New Fan Pawned Isms VAV-17 Otr lijw: VAV-r 7/17/2019 1:1t40 PM Vr Sce VSEF099350 Nontiriel IF Oil X 4' Oeyth Verve She 9 Depth Nominal 03SO Fen Fan Sze Filier Size ie. x itex r (Or,' 11 PEE NO LI AI ft FLOW 24' AIRFLOW DISCHARGE OUTLET 40" IEL SLIDES 18 lir TOR ACCESS TOP VIEW DISCHARGE VIEW !TOTES: 1AstRow magnum tr plenum iniX clearance far czneructed installations. Filler is secured in filer lime lac/Ned in unit Airflow Plenum inlet. 3. Far Rigor acce, remove bantam screws an hanger brediers to slide panel is shovek ix drawing. 4._ See installafion Occurnints for exata hanger Precast fixation S. Air valve centered between tam 1 batten panel. 9. ti essmg col un-insulated. ExtermaI insulation may be Seel supped sad installed ex required. F. Ad high & loviroltags controls have same-siela NEC playbetk de -ammo. & Allow 48^ of straight duct downstream of unit tforofft fret 'unmet and Inside ofths duct 'Astrid be equal discharge sCe 9 Terminal box somas dose Is so* hinged Allow for Gleannct IC. All wire power Sap ply required br 480 & 575 single point connection was- Attenuidor option not ova itoble with this tint Isyout. Approximate Dry Weight 106.9 Ri Weig tits reflected may vary ±5.0 Pb based upon options selected. TOPSS DImenson Dammo ALL WEIGHTS AIM DIMENSIONS ARE APPROXIMATE_ Edward Jones Tukwila VAV New Fan Powered Ream VAV-tr 01v: 1 Tags-, VAV-r 7/17/2019 4:1&411 Fig 27"; Vott, I Phase Kesler Cattrat Wiring WARNING HAZARDOUS VOLTAGE" DISCONNECT ALL ELECTRIC POW EP. INCLUDING REMOTE DISCONNECTS BEFORE SERVICING, FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY Oit DEATH A\ CAUTION USE COPPER CONDUCTORS CNLY. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS, FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT Cu stomer Notes FeaNcy — — Optlor irstatediry others, TOPSS Dinemlon Mooing ALL WEIGHTS AMI OSIENS1ONS ARE APPROXIMATE. 2 • MINE' Edward JonesTubvta VAV New Fm Powered Items VAV-Ir Qtr. 1 Tags: VAV-W 7/17/2019 4:1&41 PIA .14011.105,1"1 TER.., SOK 544 VOTES 52112AY *JAM — • • .• ••••.• - - OE 2.1n0,14.35....4.4,14161,-WWCANS 2 A.... g ALZAltraltrZTM ¢1,2.12454-.E71,7. N.-LSCA-1.72,MVILENTS (7.1 4.2,0138 .nr51,C14.15110 ^VOI C.C.& LISCOM aiCOV",41,./12. X .22422404442254YMA (POW 541205AYAVOMIZOOVIRMAZI',0470.4f &Ott= 154221420, 142 44252224444544 (:) C,A114.2 410$11gZ,4 T.INSPK.1 ../200,0= TO VAV COYFACILLEA r 422,42 COA424102 CA0055 542222AC 2242At mem et el VAC) 22.21222A4C YEA2ER CON245221 OPT:05AL 5174WD AtACTAT 242/42214 4244122A CONTAAC:2)A5 AVM 24 VAC IVA MAAC.A211. 1221440./AY 09142ACTCAS, 12VAAAAWCOA MN:04n C CC242ACTV5S 21.0CV etc ACV Ole CA14 FE /C.A25-2 01A CtS Cn6 TO 245 WA CM VA2YAACIA WarrAM. WARD 14A24 AU:SC :ECM BOARD —NEM TOMS Dumneion Orming ALL WEIGHTS AM) ONIENGDONS APE A PPROXBIATE P 3 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0131 DATE: 08/06/19 PROJECT NAME: EDWARD JONES SITE ADDRESS: 6840 FORT DENT WAY SUITE 230 X Original Plan Submittal Response to Correction Letter # Revision # before Permit issued Revision # after Permit issued DEPARTMENTS: Building Division S Public Works I 4\ Fire Preven ion • n Structural Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 08/0 / /19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning issues) DUE DATE: 09/05/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg LJ Fire 0 Ping D PW 0 Staff initials: 12/18/2013 FIulTL Ecpaliul (nit Search L&I Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries AZ I 11(1f:X 11121 p Workplace Rights Trades & Licensing MECHANICAL & CONTROL SRVCS INC Owner or tradesperson Principals Hull, Travis Edward, PRESIDENT Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) Doing business as MECHANICAL & CONTROL SRVCS INC 6426 16,th St E FIFE, WA 98424 253-926-9777 PIERCE County WA UBI No. Business type 602 338 440 Corporation Governing persons ANGELA DAWN HULL TRAVIS EDWARD HULL: Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Registered training agent. Check their eligible programs and occupations. License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MECHACS962BT Effective — expiration 01/30/2004— 02/26/2020 Bond American Contractors Indem CO Bond account no. 100239439 $12,000.00 Received by L&I Effective date 02/10/2014 02/06/2014 Expiration date Until Canceled Help us improve Bond history Insurance Continental Insurance Co $1,000,000.00 Policy no. 6023856626 Received by L&I Effective date 01/15/2019 01/23/2018 Expiration date 01/23/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&l Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Public Works Requirements Workplace safety and health Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve GENERAL HVAC NOTES 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL DRAWING. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS WHEN AVAILABLE. 2. INSTALLATION SHALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE CONSTRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFLICT SHOULD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF SUCH CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION. 3. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING LOUVERS, CONCRETE EQUIPMENT PADS, FLASHING DETAILS, ETC. 4. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS, HUMIDISTAT, PANELS, ETC. SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (WAINSCOT, DOOR HARDWARE, ETC.) NOR WITH THE ELECTRICAL SYSTEM (LIGHT SWITCHES, SPEAKERS, OUTLETS, ETC.) MOUNT THERMOSTATS 48" AFF UNO. 5. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF GRILLES, REGISTERS, DIFFUSERS AND OTHER CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT INDICATED ON ARCHITECTURAL DRAWINGS OBTAIN DIRECTION FROM ARCHITECT PRIOR TO INSTALLATION. 6. SEE ARCH. DRAWINGS FOR EXACT SIZE AND LOCATION OF LOUVERS. COORDINATE EXACT SIZE OF ATTACHED DUCTWORK/PLENUM AND/OR MOTORIZED DAMPERS WITH ARCH. DRAWINGS. 7. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 8. COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT AND DUCTWORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 9. ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES AND RECOMMENDED BY MANUFACTURER ARE PROVIDED. PROVIDE 42" CLEAR AT DISCONNECT SWITCH ON TERMINAL UNITS WITH ELECTRIC HEATING COIL. 10. GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS THROUGH ACCESS DOORS IN HARD CEILINGS AND WALLS. WHERE ACCESS DOORS PENETRATE FIRE RATED SYSTEMS THEY SHALL BE RATED IN ACCORDANCE WITH IBC REQUIREMENTS. 11. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT (VOLTAGES ETC.) 12. DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, ALLOW 18" TO THE SIDE OF CABLE TRAYS. 13. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH THE ELECTRICAL DIVISION PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 14. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. PROVIDE OFFSETS AS REQUIRED AT NO ADDITIONAL COST. 15. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 16. DUCTS AND PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM DUCT AND PIPE SECTIONS. 17. DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSION. 18. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS OR IN SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL MEMBERS, BOLTS AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 19. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS AND EQUIPMENT, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 20. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY STRUCTURAL ENGINEER. 21. PROVIDE DUCT LINING FOR THE FOLLOWING DUCTWORK: A. ALL THE AIR TRANSFER DUCTS AND CEILING RELIEF GRILLES. B. OTHER LOCATIONS WHERE NOTED ON DRAWINGS OR SPECIFIED. 22. PROVIDE VOLUME DAMPERS FOR EACH SUPPLY BRANCH, RETURN BRANCH (DUCTED ONLY) AND EXHAUST BRANCH WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. 23. PROVIDE CONICAL SPIN -IN FITTINGS FOR ALL 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE FITTINGS. 24. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED UPON SMACNA. 25. REFER TO WASHINGTON STATE ENERGY CODE COMPLIANCE REQUIREMENTS ON DRAWINGS SCHEDULE SHEETS FOR ADDITIONAL MECHANICAL PROVISIONS. 26. SEAL AND LEAK TEST DUCTWORK PER WSEC C403.2.7.3 & PER DIVISION 23 SPECIFICATIONS. 27. BALANCE HVAC SYSTEM PER WSEC C408.2.2 WITH AIR BALANCE HOOD. 28. COMMISSION HVAC SYSTEM PER WSEC 408.2. 29. PROVIDE COMPLETION/RECORD DRAWINGS PER WSEC C103.6. 30. INSULATE DUCTWORK PER WSEC. 31. PROVIDE MEANS OF ACCESSING/ADJUSTING BALANCING DAMPERS AT ALL LOCATIONS WHERE MEANS OF ACCESS HAS NOT BEEN SHOWN ON ARCHITECTURAL DRAWINGS. PROVIDE UNITED ENERTECH I -SERIES REMOTE POWER/BALANCE SYSTEM OR APPROVED EQUAL. COORDINATE LOCATION OF REMOTE JACK WITH ARCHITECT AND RECORD ON AS -BUILT DRAWINGS. 32. PROJECT CLOSE OUT DOCUMENTATION & TRAINING OF THE BUILDING OPERATIONS PERSONNEL IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT AND SYSTEMS. CLOSE OUT DOCUMENTATION SHALL INCLUDE RECORD DOCUMENTS, O&M MANUALS, APPLICABLE WSEC r,nMPLIANCF FORMS P. CALCULATIONS_ a.._ ^, a. ��:. WA 6 fl. ,kA,w, JONES OFFICE Ia�N IMPROVt�:MOL�NT ry t�t�, $i a""; �4p ��qy�°�4� a?,�u,� 5..1 ��. 1', "'^«ya'�y PROJECT SITE ADDRESS OWNER/PROPERTY PARCEL TENANT MANAGER 6840 FORT DENT WAY SUITE 230 295490-0425 EDWARD JONES REDAVIDSON TUKWILA, WA 98188 7-2669 0ECCA : 206-26-2669 C: 206-669-3773 MECHANICAL CONTRACTOR SCOPE OF MECHANICAL WORK MECHANICAL &CONTROL SERVICES 6426 18TH ST. E -INSTALL (1) NEW VAV BOX, ASSOCIATED DUCT & FIFE, WA WA DIFFUSERS. 253-926-97 - MODIFY EXISTING DUCT, GRILLES & DIFFUSERS TO ACCOMMODATE NEW FLOOR LAYOUT. GOVERNING BUILDING CODES - 2015 INTERNATIONAL EXISTING BUILDING CODE - 2015 UNIFORM BUILDING CODE PROJECT NOTES - 2015 INTERNATIONAL FIRE CODE - 2017 NATIONAL ELECTRICAL CODE 1. TENANT SPACE IS SERVED BY EXISTING PLENUM - 2015 INTERNATIONAL MECHANICAL CODE RETURN SYSTEM. - 2015 WASHINGTON STATE ENERGY CODE - 2015 WASHINGTON STATE AMENDMENTS FORT DENT PARK v2 � 2.a FORT DENT II Ln , 6840 FORT DENT WAY ,s EXISTING OFFICE BUILDING s S0 UT yc��TFR & Z �D L 405 IN ? SITE PLAN FILE COPY Permit No. M.0 - D bi Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and can ltl s I acknowledged: By. ate: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED J�-O AUG 08 2019.KW1 City of Tukwila BUILDING DIVISION VAV BOXES SCHEDULE TAG MANUFACTURER EXISTING / NEW AREA SERVED MODEL CFM RANGE MAX ESP IN WG INLET I SIZE HEATER ELECTRIC WEIGHT KW TEMP. RISE OF Hi VOLTS PH 2540 ENVIRO-TEC EXISTING STE 230 CVF-EH-II 935-135 0.45 8" 0 5.0 14.4 60 277 1 NA 2541 TRANE NEW STE 230 VSEF0803SQ 1085-160 0.5 8"0 5.5 15.7 60 277 1 104 Lb. SUITE 230 - MECHANICAL PLAN 1 /4" = 1' MECHA ICAL :.': „ ' ''CONTROLSERVICE MECHANICAL & CONTROL SERVICE 6426 18TH ST E FIFE, WA 98424 PHONE: 253-926-9777 FAX: 253-926-9222 PROJECT NAME: EDWARD JONES OFFICE TENANT IMPROVEMENT PROPERTY NAME: FORT DENT II BUILDING PROJECT ADDRESS: 6840 FORT DENT WAY SUITE 230 TUKWILA, WA 98168 T SEPARATE PERMIT REQUIREb FOR: [] Mechaniceil Electrical Plumbing . Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No c;har.ges shall be made to the scope of work wltnout prior aporoval of the Tukwila Building Division. NOTE: Revlsronswill require a new plan su Imittal and may include additional plan review. nECEIVEn CITY OF TUKWILA AUG 0 6 2019 PERMIT CENTER PROJ. NO: 52119 PROJ. MNGR: JP DRAWN BY: JM REVIEWED BY: JP DESCRIPTION: BY: DATE: MECH. SET JM 07/29/2019 MECH. FLAN M=1 U WA