Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M19-0134 - MACY'S - GAS ROOFTOP UNITS REPLACEMENT
MACY'S 17000 SOUTHCENTER PKWY M19-0134 Parcel No: Address: �=^�xx m�� Tukwila ~°U~� v�n o��m`���oa Department ofCommunity Development 630OSouthcenterBoulevard, Suite #1DO Tukwila, Washington 98188 Phpne:Zn6'431'367O Inspection Request Line: 206'438'93S0 Web site: http://www.TukwilaWA.Fov MECHANICAL PERMIT 2623049077 170008]UTH[ENTERPKVVY Project Name: MA[Y'S Permit Number: K419'0134 Issue Date: 8/29/2019 Permit Expires On: 2/26/I020 Contact Person: Name: Contractor: Address: License No: Lender: 17OUOSOUTHCENTERPARKWAY L 885 PARK AVE #213, NEW YORK, WA, 10075 JESSE[MUTICM 3Z0Z[5TNE, AUBURN, WA, 98002 COMFORT MECHANICAL INC (CONSTRUCT) 32U2[STNE, AUBURN, WA, 9800Z [OMFDM1015LA ^'' Phone, (425)251-9840 Phone: (425)251-9840 Expiration Date: 4/25/2020 DESCRIPTION OFWORK: REPLACE (4) GAS PACKAGED ROOFTOP UNITS, LIKE FOR LIKE. Valuation of Work: $41,079.00 Type ufWork: REPLACEMENT Fuel type: ELECT Fees Collected: $779.87 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKVV|LA 5ewerD|sthct: TUKVY|U\ Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VYACities Electrical Code: VVAC29646B: Code: ermit Center Authorized Signature: ` �� | hearby certify that | have read and examined this permit and know the same tn betrue and correct, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not, The granting of this permit does not presume to give authority to violate or cancel the provisions of any other gate or local laws regulating construction or the performance of work. | am authorized to sign and obtain this development permit and agree tothe conditions attached tnthis permit. Signature: Print Name: �^2S 3E�v-%- t—_�� -- ' q \O � Date: �W I ( 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: l: Work shall beinstalled inaccordance with the approved construction documents,andanychanQesmade during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code, 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion ofthis requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (2O6'431,367O). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance orgranting ofapermit shall not beconstrued tnbeapermit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance cfapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: `MECHANICAL PERMIT CONDITIONS' 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (2O6/43l,367O). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. ll: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.&[. units rated atgreater than 2,000cfm naquieauto*hutdnwn devices. These devices shall be separately zoned in the alarm panel and local U1, central station supervision is required. (City Ordinance #Z437) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall belabeled byanapproved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (|K4C606.1, 60621) 14: Remote indicator lights are required nnall above ceiling smoke detectors. (City Ordinance #Z437) 15: Duct detectors shall send asupervisory signal only upon activation. (City Ordinance #Z437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. Nowork shall commence until afire department permit has been obtained. (City Ordinance #2437) (|FC9U1.Z) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project, 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #Z437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval, ofsuch condition orviolation. 20: These plans were reviewed byInspector SlI. |fyou have any questions, please call Tukwila Fire Prevention Bureau at(ZO6)575-44U7. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)43B-935V 1400 FIRE FINAL 0703 [WE[H EQV|PEFF lOOO MECHANICAL FINAL 0609 P|PE/DUCT|mSULAT0N 0705 REFRIGERATION EQUIP 0701 K0UGM'|NN1[CHAN|[AL 0702 SMOKE DETECTOR TEST CITY OF TUKW'reA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. in o )31 Project No, Date Application Accepted: 8- D-1 - Date Application Expires: 9 - - Dc-) (For office use ly) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 26230g- '1077 Site Address: 1 700 otA 17 c-40rt+44 ha., Ay Suite Number: Floor: Tenant Name: AActc-y s PROPERTY OWNER Name: I Address: C. 5 City: State: Zip: CONTACT PERSON — person receiving all project communication Name: -r- Q Address: e co )-r4cd-oe City: State: Zip: Phone,: Fax: Email: sakc. for 4" New Tenant: D Yes 7j.No MECHANICAL CONTRACTOR INFORMATION Company Name: z". cf;Pri- Atexiiarlicq( Address:ZE 02_ c G.+. AI f city: A L State:WA zip:qtooz pty (A f tep Phone: qz s- z.s.,( qiNsFax: Contr Reg No.C.oktrom reiExp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): Describe the scope of work in detail: Replace, 0) 546 P4040 7 '1 roo-riep Use: Residential: New ..... ..... Replacement Commercial: New El Replacement Fuel Tvpe: Electric Gas Other: 1-1Mpplic-ollonsTorros-Applicat ions On Line \ 2016 ApplicationsWlechonicai Permit Application Revised I -4-I6.doos Revised: January 2016 Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are bascd on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will he reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN1 OR AIJFRORJZED AGENT: Signature: Print Name: Te-SS Date: WV Day Telephone: Z s" I et tir Mailing Address: State Zip City HAApplicationsTorms-Applicatiuns On Line'2016 ApplicatioresliMechanical Permit Application Revised 1-4-16.doex Revisod: January 2016 bh Page 2 of 2 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $779.87 M19-0134 Address: 17000 SOUTHCENTER PKWY Apn: 2623049077 $779.87 Credit Card Fee $22.71 Credit Card Fee R000,369,908.00.00 0.00 $22.71 MECHANICAL $728.04 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $549.28 PLAN CHECK FEE R000.322.102.00,00 0.00 $145,61 TECHNOLOGY FEE $29.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18310 R000.322.900.04.00 0.00 $29.12 $779.87 Date Paid: Monday, August 12, 2019 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 312100 Printed: Monday, August 12, 2019 11:01 AM 1 of 1 CAW 5 Y5 TE M 5 CO TUKWILA sTn4KIT 6209 SOUT*[ENTER OLVD TUKWILA' WA 98188 206'433'1870 CITY OF TUKWIL^ Date: 88/1I/2019 11:00:47 AM CREDIT CARD SALE VISA CARD NUMBER: ********~7666 K TR4N AMOUNT: $779.87 APPROVAL {D: 312100 RECORD #: 000 CLERK ID: kandace Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: l Type of Inspection: Address: / Date Called: 5 eciai instructions: P = Date Wanted: a,m. p.m. Requester: Phone Nv: pproved per applicable codes. Corrections required prior to approval. ;COMMENTS: • Peei c V 27 Date: 2 i2,' -2 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN '' + I N NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: 1 C/5 44//C4- /''7 4L Address: ate Called: Special Instructions: Date Wanted: cP2"'- ;� a,m. p.m. Requester: Phone No: 2S3 - Ire' L 1 Approved per applicable cedes. Corrections required prior to approval. COMMENTS• 'wn 7'�_ 14AtNMYw.Y..,�IA .I A.. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. COMFORT MECHANICAL INCORPORATED HVAC Service & Constntction Job Name: Job Address: Mark: START UP REPORT cv_s q'tic Date: udvicik,,,y1Q(,47,Ya Job Number: technician: UNIT BEING REPLACED Manufacturer: yor 6 Model #: D N10 P4 4-14-7Ai'Ak Serial #: NEW EQUIPMENT Type: Gas Manufacturer: 7/10Q..._, „ Model Number: y_suoaffq fkL-A03)))00Ne000.. , v Serial Number: i ii,,b //— Filters: XY wa Type: 710 Qty: Voltage: Actual Volts:---q-6C) Phase: 3 Air Handler [] Outdoor Unit [1 Package Unity indoor Fan Outdoor Fan Full Load Amps: 14' Full Load Amps: Actual Amps: Actual Amps: Horsepower: Q Horsepower: Belts: AX-3-51 Belts: nt'f Compressor 1 Compressor 2 Yes No Run Load: 7 Run Load: Actual Amps: .5 Actual Amps: y, 7 Oil Level: Oil Level: Suction Pressure: Suction Pressure: Discharge Pressure: Discharge Pressure: Super Heat: Super Heat: Sub Cooling: Sub Cooling: Supply Temperature: Supply Temperature: Return Temperature: Return Temperature: ELECTRIC HEAT Kilowatts: Voltage: Phase: Rated Amps: Actual Amps: GAS HEAT Manifold Pressure: Temperature Rise: WATER COOLED Supply Temperature: Return Temperature: DEFICIENCIES FOUND COMFORT MECHANICAL INCORPORATED HVAC Service& Construction Job Name: Job Address: Mark: START UP REPORT uko echnician: UNIT BEING REPLACED Manufacturer: \I Or % Model Al: E) Hi t9. su 10 PH AAA - Manufacturer: Model Number: Serial Number: Filters: Voltage: Full Load Amps: Actual Amps: Horsepower: Belts: Serial If: NEW EQUIPMENT Date: Job Number: Air Handler ( ] Outdoor Unit [] Package Uni Actual Volts: Indoor Fan 4,6 Compressor 1 Run Load: 2N Lit7Actual Amps: Actual Amps: Oil Level: Oil Level: Suction Pressure: Suction Pressure: Discharge Pressure: Discharge Pressure: Super Heat: Super Heat: Sub Cooling: Sub Cooling: Supply Temperature: Supply Temperature: Return Temperature: Return Temperature: Outdoor Fan Full Load Amps: Actual Amps: Horsepower: Belts: ,5 )1,11 Run Load: ELECTRIC HEAT Kilowatts: Voltage: Phase: Rated Amps: Actual Amps: GAS HEAT Manifold Pressure: Temperature Rise: WATER COOLED Supply Temperature: Return Temperature: Compressor 2 Yes DEFICIENCIES FOUND 'COMFORT MECHANICAL INCORPORATED HVAC Service S Constntction Job Name: Job Address: Mark: Manufacturer: VtY1i Tec nician: START UP REPORT Date: U-1( kti (AO grCiarYb Number; ON 03 UNIT BEING REPLACED Model #: Dtic7 to pi1AAA Type: Gtic -Pa Manufacturer: Model Number: Serial Number: Filters: Voltage: Serial #: NEW EQUIPMENT Air Handler [] Outdoor Unit [ j Package Uni A Actual Volts: Indoor Fan Full Load Amps: Lt 1 Actual Amps: Horsepower: Belts: /9 3 Run Load: Type: 7(),) Compressor 1 Actual Amps: C), J- Oil Level: Suction Pressure: Discharge Pressure: Super Heat: Sub Cooling: Supply Temperature: Return Temperature: ELECTRIC HEAT Kilowatts: Voltage: Phase: Rated Amps: Actual Amps: GAS HEAT Manifold Pressure: Temperature Rise: WATER COOLED Supply Temperature: Return Temperature: Phase: Outdoor Fan Full Load Amps: Actual Amps: Horsepower: Belts: Compressor 2 Yes Y No Run Load: Actual Amps: Oil Level: Suction Pressure: Discharge Pressure: Super Heat: Sub Cooling: Supply Temperature: Return Temperature: DEFICIENCIES FOUND , • - COMFORT MECHANICAL INCORPORATED HVAC Service & Construction START UP REPORT Job Name: MA a/5 Date: Job Address: Address: 70-1-70 cz,•rjt-4 P kolk../ ke.-1.43 Job Number: 33i 0 Mark: eve e ‘,L. Technician: `IS-6....Led 014 Manufacturer: e_ UNIT BEING REPLACED Model #: Serial #: NEW EQUIPMENT Air Handler [1 Outdoor Unit [] Package Unit i<t Type: - Manufacturer: Model Number: Serial Number: 1 la. ek. e_ y _s4 /.6 y AL Aob i9/1077S-2— Filters: i2 0 X ..24.3 )c-2 Voltage: 1/6-0 Actual Volts: '16.2 Phase: Full Load Amps: Actual Amps: . Horsepower: 2iBelts: Indoor Fan 6 c Compressor 1 Run Run Load: Actual Amps: Oil Level: 7 Suction Pressure: Discharge Pressure: Super Heat: Sub Cooling: Supply Temperature: 4? Return Temperature: Outdoor Fan Full Load Amps: Actual Amps: I 0 • Type: ? L City: 11 /. Horsepower: 70 Belts: 7-3 Compressor 2 Yes,‹ No Run Load: ( Actual Amps: Oil Level: Suction Pressure: Discharge Pressure: Super Heat: Sub Cooling: c7 Supply Temperature: Return Temperature: ELECTRIC HEAT Kilowatts: Voltage: Phase: Rated Amps: Actual Amps: GAS HEAT Manifold Pressure: Temperature Rise: WATER COOLED Supply Temperature: Return Tennperature: DEFICIENCIES FOUND Macy's Tacoma May 30, 2019 Tag Data - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Qty: 4 Item Tag(s) Qty Description Model Number Al RTU 10 TONS 1 3-10 Ton R-410A PKGD Unitary YSC120H4RLA A2 RTU 8,5 TONS 3 3-10 Ton R-410A PKGD Unitary YSC102H4RLA Product Data - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop All Units DX cooling, gas heat Standard efficiency Convertible configuration 460/60/3 Microprocessor controls Low gas heat Economizer Dry Bulb 0-100% with Barometric Relief Through the base electrical Non -fused disconnect Item: Al Qty: 1 Tag(s): RTU 10 TONS 10 Ton Item: A2 Qty: 3 Tag(s): RTU 8.5 TONS 8.5 Ton Oversize motor FILE Performance Data - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Tags RTU 10 TONS RTU 8.5 TONS Design Airflow (cfm) 4000 3400 Airflow Application Downflow Downflow Cooling Entering DB (F) 80.00 80.00 Cooling Entering WB (F) 67.00 67.00 Ent Air Relative Humidity (°/ ) 51.08 51.08 Ambient Temp (F) 95.00 95.00 Evap Coil Leaving Air Temp (DB) (F) 57.59 57.08 Evap Coil Leaving Air Temp (WB) (F) 57.59 56.78 Cooling Leaving Unit DB (F) 59.23 59.32 Cooling Leaving Unit WB (F) 58.22 57.65 Gross Total Capacity (MBh) 116.26 107.22 Gross Sensible Capacity (MBh) 96.80 84.16 Gross Latent Capacity (MBh) 19.46 23.06 Net Total Capacity (MBh) 110.79 100.40 Net Sensible Capacity (MBh) 91.33 77.34 Net Sensible Heat Ratio (Number) 0.82 0.77 Heating EAT (F) 70.00 70.00 Heating LAT (F) 98.10 96.80 Heating Delta T (F) 28.10 26.80 Input Heating Capacity (MBh) 150.00 120.00 Output Heating Capacity (MBh) 120,00 97.20 Output Heating Cap. w/Fan (MBh) 125.47 104.02 Design ESP (in H20) 0.800 1.500 Component SP (in H20) 0.260 0.190 Field supplied drive kit required None None Indoor mtr operating power (bhp) 1.91 2.19 Indoor RPM (rpm) 1442 1073 Indoor Motor Power (kW) 1.42 1.63 Outdoor Motor Power (kW) 0.65 0.66 Compressor Power (kW) 8.55 7.50 System Power (kW) 10.63 9.78 IPLV @ AHRI (IPLV) 12.7 12.7 RECEIVED CITY OF TUKWILA AUG 1 2 2019 PERMIT CENTC REVIEWED FOR CODE COMPLIANCE APPROVED AUG 27 2019 • City of Tukwila BUILDING DIVISION kck-0134 FLD = Furnished by Trane U. S. Inc. / Installed by Others Equipment Submittal Page 3 of 15 Mav 30.2019 � Macy's Tacoma MOP (A) 25.00 25.00 Compressor 1RLA(A) 8.20 7.80 Compressor 2RLAAA 6.10 0.23 Evaporator fan FLA(A) 3.80 0.00 Condenser fan FLA(A) 1.50 1.50 Evaporator face area (sqft) 12.36 12.36 Evaporator rows (Ench) 4.00 4.00 Evaporator fin spacing (Per Foot) 192 192 Evaporator face velocity (ft/min) 324 375 Min. unit operating weight (lb) 1058.0 927.0 Max. unit operating weight (lb} 1384.0 1282.0 Fan motor heat (yWBh) 5.47 6.83 Dew Point (F) 57.69 56.59 Run Acoustics Yen Yes Rated capacity (AHR|)(yWBh) 113.00 102.00 Rofhg charge (HFC-41OA)-cht 1 (|b) 5.6 5.9 Refhg charge (HFC-41OA)-cht2 (lb) 4.4 4.0 ASHRAESO.1 Yes Yes Saturated Suction Temp Circuit 1 (F) 48.70 52.40 Saturated Discharge Temp Circuit 1 (F) 121.58 117.10 Saturated Suction Temp Circuit (F) 52.88 49.90 Saturated Discharge Temp Circuit 2(F) 121.97 118.30 |EER() 1270 1270 EER@AHR|Conditions /EER\ 11.2 11.2 Total Static Pressure (in H2O) 1.079 1732 Length (ft) 7.39 7.39 Width (t) 4.44 4.44 Haight(fU 3.91 3.81 Indoor Fan Type ' FCCantrifugo| Indoor Fan Drive Type Variable Direct Belt Outdoor Fan Type Propeller Propeller Outdoor Fan Drive Type Oinaot Oinoot Outdoor Fan Quantity (> 1 1 Heating Type Gas Heat Gas Heat Heating Stages 2 1 FLO=Furnished by7rameL/�Inc. / Installed by Equipment Submittal Page 4mr,5 Macy'nTacoma Mechanical Specifications -3- 0 TmnR-410A PKGDUnitary Gas/Electric Rooftop May 30, 2019 General TheunbmmhaUbanonverUb|aahflow.Theooe/adngnangeohaUbebobwean115"FondD"FinnnoUnomamtundan]fr0m the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be behween115"Fond4O"F.Cno|ingperfomnanoeohaUboratedinaccordanoevvithAR|tesdngpromadurea.AUunitsohaU befactory assembled, internally wired, fully charged with R-410A. and 100 percent run tested tocheck cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiflng internal to the unit shall be colored and numbered for simplified identificadinn. Units shall bmoULus |ieb*d and |ebe|ed, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing oho|| be constructed of zinc noeted, heavy gauge, galvanized ob*ei Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test incompliance with A8TN1B117, Cabinet construction shall allow for all maintenance onone side ofthe unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. The base ofthe unit shall beinsulated with 1/8 inch, foi|'fooed, c|omed'ooU insulation. All insulation edges shall be either captured or sealed. The unit'a base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8inch high dovvnf|ovvsupply/return openings to provide an added water integrity precaution, if the condensate drain backs up, The base of the unit shall have provisions for forklift and crane |ifting, with forklift capabilities on three sides ofthe unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed, The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters nhoU be standard on all units. Optional 2-inch &1ERV8 and N1ERV 13 filters shall also be available. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. lmWoorFan The following units shall be equipped with a direct drive plenum fan design (TTy8C120F.TDyHCO74F. TNHCO92F.T/YHC102F. 120F). Plenum fan design shall include backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3b/ 5ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 81/2 ton units (standard efficiency) shall have belt drive motors with on adjustable idler -arm assembly for quick -adjustment hofan belts and motor sheaves. All motors shall be thermally protected. All 10tona. Gton (074). 7}6to8}6 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/18" copper tubes mechanically bonded to configured aluminum plate fin ohmU be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3to 10ton standard efficiency models and 4. 5, G. 7�5. 8,5ton high efficiency models, The nnionoohenne| h/po condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume,, which leads to better FlD=Furnished byTrane U.S.Inc. / Installed by Equipment Submittal Page 5of10 Others Macy's Tacoma May 30, 2019 compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual -sloped, removable and reversible condensate drain pan with through -the -base condensate drain is standard. Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid -tight conduit and an external field -installed disconnect switch. Through the Base Electrical with Disconnect Switch This 3-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a water tight enclosure with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Sequence of Operation FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 6 of 15 Others System Operating Modes: The System Controller shall send the equipment controllers Occu pied/U noccu pied, Morning Warm-up/Pre-cool, and Heat/Cool modes. If communication is lost, the equipment controllers shall operate using default modes and setpoints. Night Setback: During unoccupied mode, the system shall shut off. If the zone temperature drifts to the unoccupied heating or cooling setpoint, the system shall start up to heat or cool the zone, while the CA damper remains closed (unless economizing). Optimal Start: The System Controller shall automatically determine the optimal start time, such that each zone reaches its occupied setpointjust intime for scheduled occupancy. Demand -Controlled Ventilation: For those zones equipped with an occupancy sensor orCO2 sensor, outdoor airflow shall be reset based on occupancy status and/or measured C{J2concentration. Sequence of Operation (Changeover Bypass System) OcoupiedHemt/Cmm|: Each VAV terminal shall use pressure -independent control, with airflow measurement, to vary primary airflow to maintain zone temperature atits occupied setpoinL ThoRTU eho|| modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing based on current zone cooling/heating demands. The OA damper shall open to bring in the required amount of ventilation. Morning Warm-Up/Pre-Cool: Each VAV terminal unit shall vary primary airflow to raise/lower zone temperature to its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure otoodpointand modulate (or cycle) compressors or modulate (or stage) heat based on current zone cooling/heating demands. The OA dan-rper shall remain closed, unless economizing. Cooling/Heating Changeover Logic: The System Controller shall determine the overall system cooling/heating mode based on "voting" from each zone. When the majority qfzonesnaquinacoo|ing.theRTUoha||oparehainnoo|ingnnodmondanyaonothednaquinasheabng shall reduce primary airflow to minimum. When the majority of zones require heating, the RTU shall operate in heating mode and any zone that requires cooling shall reduce primary airflow to minimum. FLD~Furnished uyTranouS.Inc. / Installed uy Equipment Submittal Page rur/o Macy's Tacoma Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al, A2 Qty: 4 Tag(s): RTU 10 TONS, RTU 8.5 TONS May 30, 2019 EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE 1/2" NPT GAS CONNECTION (80MBH & 120MBH) 3/4" NPT GAS CONNECTION (150MBH, 200MBH & 250MBH) THROUGH THE BASE CONDENSATE 4 1/8" CONDENSER FAN CONDENSER COIL UNIT CON1ROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA, HOLE UNIT POWER WIRE CONTROL AND COMPRESSOR ACCESS PANEL PACKAGED GAS / ELECTRICAL ISOMETRIC VIEW 27 5/8"—i 33" SUPPLY 32 118" RETURN -.^17 I/2"—o- 9 7/8" ..-17 PLAN VIEW UNIT DIMENSION DRAWING RETURN 2 /8" SUPPLY 0 0 1/4" CONDENSATE 88 5/8" 5/8" 32 /4" NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS, 2, VERIFY ALL DIMENSIONS VITH INSTALLER DOCUMENTS BEFORE INSTALLATION. PACKAGED GAS / ELECTRICAL 4 1/4"---..- 5 5/8" 7 5/8" DIMENSION DRAWING 0 53 1/4' HORIZONTAL AIR FLOW FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Others Page 8 of 15 Macy's Tacoma Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU 10 TONS May 30, 2019 'ELECTRICAL / GENERAL DATA GENERAL (2)(4)(e) Model: YSC120H Oversized Motor Unit Operating Voltage: 414-506 MCA: N/A Primary Voltage: 460 MFS: N/A Unit Secondary Voltage MCB: N/A Unit Hertz: 60 Unit Phase: 3 EER 11.3 Standard Motor Field Installed Oversized Motor MCA: 22.0 MCA N/A MFS: 25.0 MFS: N/A MCB: 25.0 MCB: N/A HEATING PERFORMANCE HEATING - GENERAL DATA Heating Heating Model: Low (BTU): Input( U): 150,000/106,000 Heating Output (BTU): 120,000/84,000 No. Burners: 3 No. Stages 2 'Gas Inlet Pressure Natural Gas (Min/Mix): 4 1/2 /14" LP (Min/Max) 11"/14" Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed.Oversized Motor Number. 1 Number: N/A Number: N/A Horsepower: 2.75 Horsepower: N/A Horsepower: N/A Motor Speed (RPM): — Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 3.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 2 Number: 1 Horsepower: 4.8/3,7 Horsepower: 0.75 Phase: 3 Motor Speed (RPM): 1100 Rated Load Amps: 8.2/6.1 Phase: 1 Locked Rotor Amps: 66.1/41.0 Full Load Amps: 1.5 Locked Rotor Amps: 6.1 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Circuit #1 5.6 Ib Full Load Amps: N/A Recommended 20"x25"x2" Circuit #2 4.4 Ib Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 9 of 15 Others Macy's Tacoma Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 3 Tag(s): RTU 8.5 TONS May 30, 2019 'ELECTRICAL / GENERAL DATA GENERAL tz>tatts> Model: YSC102H Oversized Motor Unit Operating Voltage: 414-506 MCA: 23.0 Unit Primary Voltage: 46C MFS: 25.0 Unit Secondary Voltage MCB: 25.0 Unit Hertz: 60 Unit Phase: 3 EER 11.2 Standard Motor Field Installed Oversized Motor MCA: 21.40 MCA N/A MFS: 25.0 MFS: N/A MCB: 25.0 MCB N/A HEATING PERFORMANCE HEATING - GENERAL DATA Model: L w Low Heating Heating MMode (BTU): o000 Heating Output (BTU): 96,000 No. Burners: 3 No. Stages 1 'Gas Inlet Pressure Natural Gas (Min/Mix): 4 1/2"/14" LP (Min/Max) 11"/14" Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: Number: 1 Number: N/A Horsepower: Horsepower: 3.0 Horsepower: N/A Motor Speed (RPM): Motor Speed (RPM): -- Motor Speed (RPM): N/A Phase Phase 3 Phase N/A Full Load Amps: Full Load Amps: 4.60 Full Load Amps: N/A Locked Rotor Amps: Locked Rotor Amps: 42.0 Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 2 Number: 1 Horsepower: 3.7/3.7 Horsepower: 0.75 Phase: 3 Motor Speed (RPM): 1100 Rated Load Amps: 7.8/6.22 Phase: 1 Locked Rotor Amps: 52.0/41.0 Full Load Amps: 1.5 Locked Rotor Amps: 6.1 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Circuit #1 5.9 lb Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 4.0 Ib Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 10 of 15 Others Macy's Tacoma Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Gas/Electiric Rooftop Item: Al Qty: 1 Tag(s): RTU 10 TONS May 30, 2019 F istoa W.-9,1 4:-.) ....OW, PACKAGED GAS / ELECTRICAL CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAL/GAS (FIOPS) 13.0 Ib UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) 5.0Ib POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET OA 345.0 Ib O 258.0 Ib (E) LENGHT (F) WIDTH 1156.0 Ib 1058.0 Ib O O 242.0 Ib O 213.0 Ib 41" 23" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected. Estimated at +/- 10 % of the nameplate weight.. 6. Verify weight, connection, and at dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 11 of 15 Others Macy's Tacoma Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 3 Tag(s): RTU 8.5 TONS May 30, 2019 pa PACKAGED GAS / ELECTRICAL CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0lb MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAUGAS (FIOPS) 13.0 Ib UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) 5.0 Ib POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET AO 285.0 Ib O 195.0 Ib (E) LENGHT (F) WIDTH 986.0 Ib 885.0 Ib O O 234.0 Ib O 171.0 Ib 47" 22" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide, 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected. Estimated at +/- 10 V. of the nameplate weight.. 6. Verify weight, connection, and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 12 of 15 Others Macy's Tacoma Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 3 Tag(s): RTU 8.5 TONS May 30, 2019 CLEARANCE 36" CLEARANCE 46" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE CLEARANCE 36" PACKAGED GAS / ELECTRIC CLEARANCE 88 5/8" PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING CLEARANCE FROM TOP OF UNIT 72" 53 1 /4" FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 13 of 15 Others STRUCTURAL CALCULATIONS Macy's Distribution Center RTUs 17000 Southcenter Parkway Tukwila, Washington AUGUST 6, 2019 FILE PREPARED FOR: Comfort Mechanical 3202 C S. Aubu 2FOR OD COMPLIANCE APPROVED AUG 27 2019 City of Tukwila pREpASOILIDING DIVISION Moore E gineenng Croup PO Box 399 Snohomish, Washington RECEIVED CITY OF TUKWILA AUG 1 2 2019 PERMIT CENTER Moore Engineering Group yso\G\ 0 st4 GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRI I'hRIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT RTU-1, 2, &3 -1,260 POUNDS RTU-4 -1,485 POUNDS EARTHQUAKE SDS = 0.966 SITE CLASS D WIND 110 MPH, EXPOSURE B, Kzt= 1.0 STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION„ 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPEC TED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING I41IN%MUM STANDARDS: JOISTS: (4x MEMBERS) HEM -FIR NO. 1 Fb = 975 PSI, Fv = 150 PSI TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-C-2019. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER OR AS INDICATED IN THIS DOCUMENT. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 9. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". a 10. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 11. NAILS UTILIZED SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: NAIL 8d l Od 16d SHANK DIAMETER 0.131" 0.148' 0.148" HEAD DIAME 1'ER 0.281" 0.312" 0.344" MINIMUM LENGTH 2-1/2" 3" 3-1/4" 12. CONNECT THE UNITS TO THE METAL CURB ADAPTERS AND THE METAL CURB ADAPTERS TO THE EXISTING METAL CURBS WITH A MINIMUM OF (3) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT AND THE THIRD SCREW AT APPROXIMATELY THE MIDDLE OF THE UNIT ON EACH SIDE. 13. CONNECT THE UNITS TO THE METAL CURBS WITH A #12 SHEET METAL SCREWS AT 24" ON -CENTER ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNITS AND THE REMAINING SCREWS APPROXIMATELY EQUIDISTANT BETWEEN THE CORNERS. 14. AS AN OPTION, CONNECT THE NEW UNITS TO THE METAL CURB ADAPTERS WITH FOUR (4) 18 GAUGE x 3-1/2" WIDE GALVANIZED METAL STRAPS WITH (4) #12 SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB ADAP FER IN EACH CORNER ALONG THE LENGTH OF THE UNIT AS SHOWN ON THE A i iACHED DETAIL. s METAL- , — J AETAL_ rcAr: o Moore Engineering Group PROJECT: IJ11�5i}"jr� ENGR: KWM DATE: /0/9 SCALE: SHEET Moore Engineering Group PROJE 4,04 CorrEVO,-, ENGR: DATE: SCALE: 4/0 SHEET PROTECT DESCRIPTION: The project consists of the replacement of four existing rooftop mechanical units. LOADS: LIVE DEAD DEAD + LIVE WIND SEISMIC EQUIPMENT Unit Existing Curb Curb Adapter Total Dimensions Roofing and re -roof 1/2" plywood sheathing 2x6 CO 24" on -center 6x20 Glulam @ 20' on -center Insulation MEP Lights Total Dead 110 mph, Exposure B Latitude Longitude Site Cass SDS = Existing RTU-1,2, &t3 860 100 960 pounds Existing RTU4 Unit 582 Existing Curb 180 Curb Adapter Total 762 pounds Dimensions 4.0 1.5 1.1 3.7 1.0 2.0 1.0 14.2 25 PSF 39.2 PSF 47.451 -122.259 D WA DNR 0.966 New RTU-1, 2, &3 939 100 221 1,260 pounds 88"x53"x71" high New RTU4 1,112 180 193 1,485 pounds 88"x53"x71" high Moore Engineering Group PROJECT: MACY'S Mgr. CENTER RTUs ENGR: KWM DATE: 8/6/ 1 9 SCALE: SHEET ATC Hazards by Location 8/5/2019 arc Hazards by Location Search Information Address: 317 NW 41st St, Seattle, WA 96107, USA Coor:Nnates: 47.451, -122259 Elevation: ft Ttmestamp: 2019-08-05721:5821.1352 Huard Type: Seismic 12efsrence Document IBC•2015 Risk Category. II Site pass: D MCER Horizontal Response Spectrum 06(9) 1.40 1.20 1.00 0.80 0.80 0.40 0.20 0.00 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Period (s) Design Horizontal Response Spectrum sa(9) 0.80 0.60 0.40 020 0.00 Basic Parameters Nun. Value Description Ss 1.449 MCER ground motion (p.rlod 02s) S1 0.54 MCER ground motion (period=1.0s) Stu 1.449 Site -modified spectral acceleration value SM1 0.809 Skeanodiflad spectral acceleration value Sim 0.968 Numeric seismic design value at 0.2s SA SD1 0.54 Numeric seismic design value at 1.0s SA Additional Information 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Period (s) Nam. Value Description SDC D Seismic design category F. 1 Site amplification factor at 0.2s F. 1.5 Site amplification factor at 1.0s CR8 0.945 Coefficient of rick (0.2s) CR1 0.93 Coeffidant of riek (1.0s) PGA 0.596 MCEO peek grand acceleration FpG, 1 Sit. rnpltlioation factor et PGA PGAe1 0.598 Site modified peek ground aocubration TL 6 Long -period tranaltlon prtod (s) SsRT 1 A49 Probabilistic rick-targ.bd ground motion (02s) S.UH 1.534 Factored uniform -hazard spectral acceleration (2% probability of ezceedanc. in 50 years) SsD 3235 Factored detrmirdsdc acceleration value (0.2s) S1 RT 0.54 Probabilistic Milt -targeted ground motion (1.0s) S1UH 0.58 Factored uniform -hazard spectral acceleration (2% probability of exceadanoe in 50 years) B1 D 1.037 Factored damrminkilc acceleration value (1.0s) POAd 1.188 Factored deterministic .000lrrIon value (PGA) ',/g4 77irr vaults indicated ham DO NOT maws any state or local .mwdm.ntato the values or any delineation area made during the building code adoption promos. Wsra ahoutd confirm any httpsJ/hazards.atcouncil.orgHt/seismic?Iat=47.451&Ing=122.259&address=317 NW 41st St%2C Seattle%2C WA 98107%2C USA 1/2 Moore Engineering Group PROJECT: DPI a w-foLt ENGR: DATE: SCALE: SHEET Moore Engineering Group PROJECT: MAC i D r5nu)T CE4-rafiL Fro, ENoR: _LW ©ATE: 8Al I q I SCALE: SHEET Moore Engineering Group PROJECT: Carr& rL ENGR: AV V ©ATE: s/4/i9 SCALE: SHEET Lateral RTUs 1 through 4: ASCE 7 Ref. qz = 0.00 *Kzt*Kd*Ke*V2* 0.00256*Kz*Kzt*Kd*Ke*V2* Ip 26.10-1 Ip Ip = 1.00 Ka 0.85 Table 26.6-1 1<zt = 1.00 26.8.2 Ke = 1.00 Table 26.9-1 Kz = 0.70 26.10-1 V = 110 mph Ip = 1.00 qz = 18.43 psf qh 18.43 psf Unit Height (h) 71.00 inches Unit Width (d) 53.00 inches Unit Length (1) 88.00 inches Unit Weight 1485.00 pounds Bldg. Height 20.00 feet Af = 43.39 sf Bh = 147 sf 0.1*Bh = 14.67 Adjustment 0.30 Gcr 1.60 29.4.1 qh * GCr * Af = 1283 pounds 29.4-2 h/d = 1.34 Ar = 32.39 sf • = 1.50 • = qh * GCr * Ar = 895 pounds 29.4-3 1,485 or W= 1,260 > 895 no uplift SEISMIC: F(0.4* ap* SEG* Wp / Rp/ !Ai ÷ p = 2*z/h) Sds 0.966 Fp = 717 pounds 29.4.1 13.3-1 Moore Engineering Group PROJECT: MACY'S DIST. CENTER R'TUs ENGR: KWM DATE: 9/67 1 9 SCALE: SHEET �....... t . 12 of 24 t,tjt---tttr---tHtt• • • j • J t • 1 ; : • • : • . . • : • j , • I, I r 41- T • t -1,7, en. . I j 0:*: • . ; • ; j!. ' t j 6. Maintain level tolerance to 1/2" across the entire width and length of unit. AWARN NG Excessive exposure of this furnace to contaminated combustion air may result in equipment damage or personal injury. Typical contaminates include; per- manent wave solution, chlorinated waxes and clean- ers, chlorine based swimming pool chemicals, water softening chemicals, carbon tetrachloride, Halogen type refrigerants, cleaning solvents (e.g. perchloro- ethylene), printing inks, paint removers, varnishes, hydrochloric acid, cements and glues, antistatic fab- ric softeners for clothes dryers, masonry acid wash- ing materials. RIGGING AND HANDLING Exercise care when moving the unit. Do not remove any packaging until the unit is near the place of installation. Rig the unit by attaching chain or cable slings to the lifting holes provided in the base rails. Spreader bars, whdse length exceeds the largest dimension across the unit, MUST be used across the top of the unit. A CAUTION If a unit is to be installed on a roof curb other than a YORK roof curb, gasketIng must be applied to all surfaces that come In contact with the unit under- side. A CAUTION Before lifting, make sure the unit weight is distrib- uted equally on the rigging cables so it will lift evenly. Units may be moved or lifted with a forklift, Slotted openings In the base rails are provided for this purpose. LENGTH OF FORKS MUST BE A MINIMUM OF 60 INCHES. A CAUTION All panels must be secured In place when the unit is lifted. The condenser coils should be protected from rig- ging cable damage with plywood or other suitable material. 264973-YIM-C-1208 FIGURE 5 - UNIT 4 POINT LOAD TABLE 3: UNIT WEIGHTS Model Shipping Weights (lb.) Operating Weight.' (lb.) DM078 1056 1041 # DM090 865 860 DM102 880 DM120 1131 1116 DM150 1210 1195 DH078 888 883 DH090 895 890 DH102 905 900 DH120 1222 1207 DH150 1212 1197 w/Econ. 85 84 w/ PE 150 148 w/Elec. Heat 49 49 w/Gas Heat2 110 110 t 54 kW heater. 2. 8 Tube Heat Exchanger. TABLE 4: 4 POINT LOAD WEIGHT Model Location (Ibs.)1 A 8 C D DM078 228 195 285 333 DM090 192 143 224 301 DM102 195 146 226 306 DM120 245 209 305 367 DM150 262 224 327 382 DH078 197 147 230 309 DI-1090 199 148 232 311 DH102 201 150 . 234 315 DH120 265 226 330 386 DH150 263 224 327 383 1. Weights include largest gas heat option. Johnson Controls Unitary Products 14 of 24 264973�M-0 208 — TABLE 5: 6 POINT LOAD Ell ' Model Locatm(lbs.)l 4 ' e o D s F oM078 lk 140 127 185 205 228 ` nMo$u�� ^ �on ��n m *m 1m 211 oM102 137 ne ma wo 175 ow oM`on 168 151 ,00 198 219 ew oMIsn ` 180 161 wo 212 zm ua o*078 138 ' 113 uo w$ 176 210 uwono 139 113 o^ wr 128 om oM102 141 nn eu 149 180 uo oH120 ,m 163 wr cw 237 264 1- Weights Include largest gas heat cp !on, , FIGURE 6 - UNIT 6 POINT LOAD Unit Model Number X Y oM078 471m 261/2 oM090 28 23 ww102 38 23 omixm *7112 251m oMmn 47112 251a oxo78 oo zn uwoyu uo uo DH102 *u 23 Dx120 *71/2 25112 Vn150 *71/2 25112 FIGURE 7~ UNIT CENTER OF GRAVITY CLEARANCES All units require particular clearances for proper operation and service. Installer must make provisions for odoqoaha combustion and ventilation air inaccordance wddhsection 5.3 ufAir for Combustion and Ventilation nfthe National Fuel Gas Code, ANSI Z223.1 —Lotnn\Edihon (in U.S.A.), or Sections T2. 7.0, o,7.4 of Gas innbsUu8on Codes, GDA'B149.1 (|n Canada) - Latest Edition, and/or applicable provisions ofthe local building codes. Refer toTable Tfor clearances required for combustible Construction, servicing, and proper unit oper- °U���i ��~^^~^^^^^~~~/ Do not pennit overhanging structures or shrubs to obstruct condenser air discharge outlet, combustion air Inlet mvent outlets. |AWARNING Excessive exposure bncontaminated combustion air will result in safety and performance related prnh' |omm.Toma\nta\nnombwodnnairqualihy,ihomoom- nnw"ded nvumo of combustion air Is the outdoor air supply. The outdoor air supplied for combustion should be free from contaminants due to chemical exposure that may be present from the following sources. ^ Commercial buildings ^ Indoor pools ~ Laundry rooms ^ Hobby o,craft rooms ^ Chemical storage areas The following substances should boavoided to maintain outdoor combustion air quo8ty. , Permanent wave solutions ^ Chlorinated waxes and cleaners ^ Chlorine based swimming pool cleaners ^ Water softening chemicals ` De-icing salts urchemicals ^ Carbon tetrachloride ` Halogen type refrigerants ^ Cleaning solvents (such mopeoh|ornothy|nno) ^ Printing inks, paint removers, varnishes, etc. ° Hydrochloric acid ^ Cements and glues ^ Anti -static fabric softeners for clothes dryers ° Masonry acid washing materials 12 Johnson Controls Unitary Products 264973-YIM-O208 ----'-----------------........ ..... ... ... .... ... -------.......... --------------'-------'--'---- DUCTWORK Ductwork should bndesigned and sized according to the methods |nManual Dnfthe Air Conditioning Contractors of America (\OOA)mao recommended by any other recog- nized authorityounhooASHRAGorGMACNA. Aclosed return duct system should he used, This will not preclude use ofeconomizers nroutdoor fresh air Intake. The supply and return air duct connections at the unit should be made with flexible joints tuminimize noise. The supply and return air duct systems should be designed for the CFMand static pressure requirements nfthe job. They should NOT be sized to match the dimensions n[the duct connections nnthe unit, Refer txFigure 8for bottom air duct openings. Refer mFig- ure 2 u FIGURE i1'PREDAT0RmROOF CURB DIMENSIONS DUCT COVERS Units are shipped with the side duct openings covered and a covering over the bottom cf the unit. For bottom duct appUoo Uon, no duct cover changes are necessary. For side duct application, remove the side duu�covers and Install over the bottom duct oponingx. The panels removed hom the side duct connections are designed tnhereused bysecuring each panel to its respective downflnwopening. But keep In mind that the supply panel |oinstalled with the painted surface UP, facing the heat exchanger, while the return panel |nInstalled with the painted surface DDYVNwfacing the dm*nOmwduct opao|nW. The supply panel Is 000u,ad with the bracket (already inplace from the factory) and two screws, It's usnug fit for the panel when sliding it between the heat exchanger and unit buttnm, but them Is mom. The n$um panel Is secured with four screws. ^ NSULATED DECK UNDER CONDENSER SECTION INSULATED DECK UNDER COMPRESSOR SECTION FIGURE 12'SUNLJNEn*TO PREDATOR" TRANSITION ROOF CURBS Johnson Controls Unitary Products LEFT FIGURE 8 - UNIT DIMENSIONS TABLE 6: UNIT HEIGHT Unit Model Number X DM078 50 3/4 — DM090 42 DM102 42 DM120 50 3/4 DM150 50 3/4 DH078 42 DH090 42 DH102 - 42 DH120 50 3/4 DH150 50 3/4 TABLE 7: UNIT CLEARANCES Top1 72" Right 12" Front2 36" Left 36' Rear3 36" Bottom4 0" 1. 2. 3. 4. Units must be installed outdoors. Overhanging structure or shrubs should not obstruct condenser air discharge outlet. The products of combustion must not be allowed to accumulate within a confined space and re -circulate. To remove the slide -out drain pan, a rear clearance of sixty inches is required. If space is unavailable, the drain pan can be removed through the front by separat- ing the corner wall. Units may be Installed on combustible floors made from wood or class A, B or C roof covering materials. DETAIL A LL Gas Pipe Inlet 5-1/4 View of waif Across from Colt Johnson Controls Un Ty Products 264973-YIM-C-1208 Fa enwr,Jp Olmensloim See Patel? a NOTE: A one -inch clearance must be provided between any combustible material and the supply ductwork for a distance of 3 feet from the unit. DETAIL B DETAIL C NOTE: If the unit includes gas heating, locate the unit so the flue exhaust is at least: • Three (3) feet above any forced air inlet located within 10 horizontal feet (excluding those Integral to the unit). • Four (4) feet below, four (4) horizontal feet from, or one (1) foot above any door or gravity air inlet into the build- ing. • Four (4) feet from electric meters, gas meters, regula- tors, and relief equipment. 17 of 24 Tr4Ne.- b I , g L- D i-130 q7D () v 1, K 18 of 24 General information : The installation must conform all standards and regulations. A. Receptionmfunits 1)Rooftop curb (YCDnccesso,iev Rooftop curbs are available an on accessory for ^down' Oow^uohv.Thevurbwa,00uppUodpro'asvomblodnnwmo' don pallets, packed under plastic film. Two types vfself- adhesive nea|vvmprovidodtoenvv,vthvmoftup'moftup curb seat iuleak-tight {4Vnnmwide for the perimeter, 20mm wide for the nmvspinoon). 2) Rooftop unit The unit iosupplied on awooden frame. |tixrecommen- ded mohwck^hemo,h|no'uoondNunuponmoopdun.Tho' mu,mmvuweyynnhond|w\heunk: 1> Use the openings in the wooden fmvm to handle the machine using nfork lift, imaccordance with applicable safety regulations. 2>Use alifting beam correctly adjusted tnfit the unit (fiyv' a}mmdling Positioning and Ming. The units are supplied vnthe truck but are not unloaded. Anopening ioprovided oneach cor- ner nf the unit'ubase tnfacilitate handling. 4shackles and 4 slings are required. Use e lifting beam to prevent the cables pressing too hard ontop ofthe unit during lifting. Figure indicates the position ofthe centre nfgravity and the lifting recommendations. Spreader bar Cl-As Sue fail � Detail "A" Table 4:Wegtho¢er mf gravity (figwnm1) ' YCo/YCxn60 340 4,2 mm mw 4,8 mm sw YCDNCH om 906 6,5/cl rr- `mm mm 060-076,*rcuu om^w.vcircuits uoit`�'�=^''.~�ovm` eonn `:`:IHmxvu`cm|smv homa i vCD/vCHms vCDIYCHv85 vmONc*100m Yoc/YC*1uoH vCnfYu*nn voD/Yox150 zm ox m 65 22 65 22 oo 34 85 34 e m YCDNCH 175 om vCDvCHnm 260 YCD/YCH 250 260 30 38 95 34 no xs 110 36 Macy's Tacoma Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 3 Tag(s): RTU 8.5 TONS PACKAGED GAS / ELECTRICAL CORNER WEIGHT R-F May 30, 2019 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY VVEIGHTS ECONOMIZER 36.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC REUEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAUGAS (FIOPS) 13,0 lb UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) 6.0 lb POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR. SUPPLY 1 RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT. ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING j NET 0 285.0 Ib 0 195.0 Ib (E) LENGHT (F) WIDTH 988.0 Ib 885.0 Ib 0 234.0 Ib 0 171.0 Ib 47" 22" NOTE: 1. All weights are approximate. 2. Weights for options that are not Ilst refer to installation guide. 3. The actual weight are listed on the unit nameplate. 4, Refer to unit nameplate and Installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weigh; for the configuration selected, Estimated et +1- 10 56 of the nameplate weight.. 6. Verify weight, connection, and all dimension with Installer documents before Installation. 7. Comer weights are given for Information only. 8. NaVShIpping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Furnished by Trene U.S. Inc. / Installed by Equipment Submittal Others 20 of 24 KTLi 1„2,1 SUBMITTA SUBMITTED TO: JOB NAME COMPANY: EQUIPMENT DRAWN BY: NOTES: WEIGHT: 2211 Ib DATE: 5110 Part Number: CA-TRN-543-YRK-564 THC 048E-060E,072A-120A; TSC,YSC 072A,E-120A,E; WSC 060E,072A,B,E,090A,B,E,092A-120A; YHC 048E-060E,D72A,B-120A,B; THC,YHC 072E YORK: EXI RJA BP,DF,DH,DM,XP,ZR,ZF 078.150; DJ 150; DR 090.150: ZH,ZJ 031-150 IJ 111`/V LAID I II1 V RIA � SIA f STING & S/A I Ill i ! i El 26.125 I.D. 83.500 80.500 1.D. 18,600 ID. 82.125 1 Features: • Fully assembled curb adaptor. • Includes internal duct transitions. • Internally insulated with 1" -1,5" Ib insulation. GaskeUng package provided. • Adaptor pans and supports provided / field installed Curb Adaptor Information • .To verify that the curb adaptor shown on this page is the correct adaptor for you job be sure the existing curb is the same size as the dimensions provided. (The bottom dimensions of curb adaptor are larger than existing curb outside dimension.) • Before new HVAC unit is set in place, inspect structural stability of existing curb and building's roof load capability. Reinforce if required. • Ali curb adaptors will increase the systems external static pressure and must be included when calculating unit requirements. • Curb adaptors are designed to attach to an existing curb with side x side duct connections. The curb adaptor is not designed for use with concentric duct configuration. • No calculations are available for this product. For a calculated product; please contact factory for part number, pricing, and lead time. • Please contact factory for more detailed dimensional information If required. Designs are based on standard factory dimensions, and may differ In the field. 49.375 46.375 I.D. 1 14.0.00 --— — L � 52.000 THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND I5 DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS MI NOT 0E DISCLOSED OR USED 1MTHOUT MICROMETLS WRITTEN CONSENT FORM NO.6697-1P MICROMETL CORP. - 3035 NORTH SHAOELAND AVENUE, SUITE 000 - INDIANAPOLIS, IN 40726 • 1-800-662.4822 - MICROMETL SPARKS - 905 SOUTHERN WAY- SPARKS, NV 89431 • 1•000.004-4082 21 of 24 Macy's Tacoma Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU 10 TONS r".6, 11% PACKAGED GAS / ELECTRICAL CORNER WEIGHT RTC -a May 30, 2019 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAUGAS (FIOPS) 13.0 Ib UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) 5.0 lb POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 345.0 Ib Q 258.0lb (E) LENGHT (F) WIDTH 1156.0 Ib 1058.0 Ib t t�J 242.0 Ib [ 213.0tb 41" 23" NOTE: 1. All weights are approximate. 2, Weights for options that are not fist refer to Installation guide. 3. The actual weight are listed on Ole unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5, The weight shown represents the typical unit operating weight for the configuration selected. Estimated at +/- 10 % of the nameplate weight.. 6. Verify weight, connection, and all dimension with Installer documents before Installation. 7. Comer weights are given for Information only, Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Furnished by Trane U.S. inc. / installed by Equipment Submittal Others 22 of 24 evis eobssi SUB SUBMITTED TO: COMPANY: DRAWN BY: TTA EIGHT: 1931bs DATE: / 0 JOB NAME EQUIPMENT: NOTES' NEW TRANE UNITS (TRN-543) Part Number: QS0111.08-CA THC 048E-060E,072A-120A; TSC,YSC 072A,E-120A,E; WSC 060E,072A,B,E,090A,B,E,092A-120A; YHC 048E-060E,-072A,B-120A,B; THC,YHC 072E XISTING UNIT (TRN-591) TRANE: TCD 102A,B,103B,C,120A,B,121B,125C,150C; TFD 102A,103C,120A,B,126C,150C; WCD,WFD 102A,120A,B; YCD 102A,B,103B,C,120A,B,C-H,1218,150C; YFD 102A,B,103C,120A,B,C-H,1216,150C EXISTING S/A EXISTING R/A EXISTING EXISTING S/A R/A 63.500 0.0. 18.500 I.D. 26,125 1.0. 14.000 89.694 0.0 49,375 O.D. 46.375 1.0. 59.882 0.0. Fealures: • Fully assembled curb adaptor. ile745-•1&---- AilVV‘ • Includes internal duct transitions. • Internally insulated with 1" - 1.5" Ib Insulation. Gasketing package provided. • Adaptor pans and supports provided / field installed Curb Adaptor Information • To verify that the curb adaptor shown on this page is the correct adaptor for you job be sure the existing curb is the same slze as the dimensions provided. (The bottom dimensions of curb adaptor are larger than existing curb outside dimension.) Before new HVAC unit is set In place, inspect structural stability of existing curb and building's roof load capability. Reinforce If required. • All curb adaptors will increase the systems external static pressure and must be included when calculating unit requirements. • Curb adaptors are designed to attach to an existing curb with side x side duct connections. The curb adaptor is no designed for use with concentric duct configuration. • No calculations are available for this product. For a calculated product, please contact factory for part number, pricing, and lead time. • • Please contact factory for more detailed dimensional information if required. Designs are based on standard factory dimensions, and may differ In the field. THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT T E CQUTSNTMLL NOT EIE DIsc0.OSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT FORM No 4272.21. MICROMETL CORP. • 3035 NORTH SHADELAND AVENUE, SUITE 300 - INOIANAPOUS. iN 46226 -14300.662-4822 — MICROMETL SPARKS . 905 SOUTHERN WAY. SPARKS, NV $9431 - 1400464-4662 23 of 24 Macy's Tacoma Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al, A2 Qty: 4 Tag(s): RTU 10 TONS, RTU 8.5 TONS EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4-14 NPT DIA. HOLE 4 1/2" NPT GAS CONNECTION (SOMBH & 120MBH) . 3/4" NPT GAS CONNECTION (150MBH, 200MBH & 250MBH) THROUGH THE BASE CONDENSATE 4 us - May 30, 2019 CONDENSER FAN CONDENSER COIL UNIT CONTROLWIRE 718" DIA. HOLE, SERVICE GAUGE PORT ACCESS 1 3/8" DLA. HOLE UNIT POWER WIRE ONTROLAND COMPRESSOR ACCESS PANEL PACKAGED GAS 1 ELECTRICAL ISOMETRIC VIEW 27 5/8"--- -1 33" SUPPLY 32 1/8" RETURN 1/2" PLAN VIEW UNIT 7/0" 17 1/2'-""- DIMENSION DRAWING 19 1/4' CONDENSATE 88 5/8" /8" 4 PACKAGED GAS / ELECTRI NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ONALL UNITS. 2. VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. -..................- 1111 241/2" , • 9 5/8" 5 518" MB IMINNIMIIIIIIIIIIIMMElimiRINE 4 1/4" 5 6/8' 7 St * *.AL • t; /4" DIMENSION DRAWING HORIZONTAL AIR FLOW FLD = Furnished by Trane U.S. inc. / Installed by Equipment Submittal Others 24 of 24 014 ftgoi City of Tukwila Department of Community Development 1/2/2020 JESSE CHUTICH 3202 C ST NE AUBURN, WA 98002 RE: Permit No. M19-0134 MACY'S 17000 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/25/2020. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/25/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: MI9-0134 6300 Southcenter Boulevard Suite #100 • Tukwila. Washineton 98188 • Phone 206-431-3670 • Fnr 2116-171-?615 COORD COP'( PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0134 PROJECT NAME: MACY'S SITE ADDRESS: 17000 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # DATE: 08/12/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: (1\f AJuildintN B iv s on1t Public Works It'rre Prevention Kw& Structural Planning Division Permit Coordinator 11 PRELIMINARY REVIEW: Not Applicable L. (no approval/review required) DATE: 08/13/19 Structural Review Required REVIEWER'S INITIALS: DATE: C APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/10/19 n Li Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Ei Fire 0 Ping PW 0 Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Page 1 of 2 Home, 11,spanol Contact Safety & Health Claims & Insirance Washington State Department of / Labor & Industries iSearch L&I L_ A-Z I ndcx 11011) M 1.&1 VVorkplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; Certifications & Endorsements License Verify the contractors active registration / Iicense 1 certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOM1015LA Effective — expiration 06/01/1999— 04/25/2020 Bond Lexon Ins Co Bond account no. 9815017 Active. Meets current requirements. $6,000.00 Received by L&l Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Insurance Federated Mutual Ins Co $1,000,000 00 Policy no. 9828233 Received by L&I Effective date 06/05/2019 06/01/2019 Expiration date 06/01/2020 Insurance history Help us improve CIGArIA 1 PA TO—rV-VA 'MI-VA/EMI GT A 1).c A A11--- Q00/1(110 PARCEL Parcel 262304-9077 Number Name 17000 SOUTHCENTER PARKWAY L Site 17000 SOUTHCENTER PKWY 98188 Address POR OF NE 1/4 OF SW 1/4 DAF BEG AT NE COR OF SE 1/4 SEC 26 TH N 88-05-42 W ALG N LN OF SD Legal SE 1/4 2678.68 FT TO CENTER OF SEC 26 & TPOB TH S 01-12-25 W ALG E LN OF NE 1/4 OF SW 1/4 657.29 FT TH N 88-00-36 W 631.93 FT TO ELY MGN OF MESS BROS CO RD TH N ALG SD ELY RD MGN TO N LN OF NE 114 OF SW 114 TH S 88-05-42 E ALG SD N LN 632.65 FT TO TPOB LESS W 6 FT FOR ST REVISIONS ' )KWI!a BLlllli i ) ^rev 5 ns will t neiv Tar, submittal afic .. r. ,L� _I Dan review 0 J6705-' 'k 91616700 1 0315 • 16890 ; M15 641' 6830 •r!l1,�� 90 46831 ,16875 i001070 C I 17000 g' 06901 I 1; °076 `36 14692s AREAS OF WORK 0020 0 169*43 -167 Ca 3070 i 4.7100 7 O1 9143 i 7135 I . 0010 y17150 �85 • D71 117189 •• - 1� Kin Can 0.s �s rx's-0RIm-K'ngaunty.Gl Ifer,XinHs•�nH unt -01 17195f. - Assam as orrae, xing ce.nriGls center { PROJECT DESCRIPTION: 1. REPLACE (3) 8.5—TON AND (1) 10—TON GAS PACKAGED ROOFTOP UNITS WITH NEW SAME CAPACITY GAS PACKAGED ROOFTOP UNITS WITH ECONOMIZERS AND ADAPTER CURBS. GENERAL NOTES: 1. ECONOMIZERS TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2.4X6 LUMBER TO BE ADDED TO ROOF FRAMING UNDER 10— TON UNIT PER STRUCTURAL CALCS. 3. THERMOSTAT TO PROVIDE MINIMUM 50 DEADBAND. 4.7—DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. 5. INSTALL GFCI OUTLET WITHIN 25' OF UNITS. 6. ALL UNITS HAVE EXISTING RETURN DUCT SMOKE DETECTORS. 7. PROVIDE COMMISSIONING REPORTS. / Equipment - - • ule (New) ���� 'II • 111 • 111• ��- �� � 11 111 • 111 �_��� � 11 • 111 111 _® Project Information Protect Title: Macy's Dlstrill Center Data 1/1/2015 Applicant Infomlation. Provide contact informatio forindividual who can respond to For Building Dept. Use inquiries about compliance form information provided. Company Name: COMFORT MECHANICAL Company Addiese: 3202 C ST NE AUBURN, WA 98002 Applicant Name: JESSE CHUTICH Applicant Phone: 425 251 9840 Project Description ❑New Building ❑Building Addition ❑Tenant Improvement [ZSystem Retrofit [-]NO System Changes Briefly describe mechanical systems in REPLACE (4) GAS PACKAGED ROOFTOP UNITS WITH NEW SAME CAPACITY UNITS. the text box provided ❑Total Bldg Perfommnce (TBP) This path includes all mandatory provisions perC401.2 Option 2 MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required ❑ Load calculalionsummary ❑MECH-LOAD-CALC Form Design Load Calculations PNvidedesign load calculationsfor all mechanicalsystems and equipment serving the building heating, cooling or —Iffeling needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance Wommation then the MECH-LOAD-CALC tone is not requied. 0 Mechanical Plans ❑ MECH-EQ Forms (TBD) Mechanical Schedules Indicate location of equipment compliance mformehon ifprevided on plans than MECH-EQ forms are not required, however, Include on plans all applicable compliance information listed in MECH-EQ tables. ❑ DOAS is required per C403.6 effective July 1 2017 (office, retail, education, library and fire station occupancies) AP occupled conditioned areas shall be served by a DOAS that delvers required vsnhlahon airIn a manner that d s not requse space conditioning fan operation Space conditioning fans cycled off when no heating or cooling is required. Dedicated Outdoor Air ❑ Ven[lat on provided via natural ventilation per 20151MC In lieu of DOAS (C403.6 Exception 1) System Requirements and ❑ 2 en: latlon and space conditioning provided by a HEVAV system per C403 7 in lieu of DOHS (C403.6, Exception High Efficiency VAV ❑ DOAS included in project, although not required (occupancy not office, retail, educatlon, library or fire station) Alternate ❑ DOAS n+laced allowances included in project: ❑ Presa pt ve vertical fenestration maximum area allowance increased to 40% per C402.4.1 4 with 100%of conditioned floor area in building served by DOAS. El Exception to air economizer per C403.3 Exception 1, include MECH-ECONO torn. ❑ Project includes HVAC air distribution systems that provide heating andfor cooling If yes provide a MECH FANSYS SUM form. Fan Power ❑ Foroneormoresystems,thetotalfanmotornameplatehpmailfansinRVACsystemexceeds5hp. If yes, provide a seperste MECH-FANSYS form foreach HVAC system —ding, the 5 horsepowerthreshold Refer to Section C403 2,11 and MECH-FANSYS-DOC forrequmrem-0 and exceptions. ❑ HVAC Hydronic Systems Hydmnc chiliad water ❑ Water -loop heat pump ❑ No hydronic systems ❑ Hydronk heating water El Geothermal ❑ 0406.2 :Aom efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in fables C403.2.3(i)(9) orah,-Io-wsterhe.f pumps and heat recovery chillers. All equipment listed In fables C403 2.3(i) (7) must be 1S%mom efficient than minimum m requirements All stand alone supply, returnend exhaust fens aver ihp must have FEQ 2 71 and must be C406 Additional Efficiency -mctedwithin 10%ofinexrmumWaloretaNcprassuie. ❑ C406 6 Dedicated outdoor air system (DOAS) Options - Mechanical Requires 90%of—anionedgoorame to be served bya DOHS per C403.6that delivers required ventilation airing en er that does not mgmm space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requims90%offlooremabein occupancy types listed in C40671 and that 60% of annual hot waterenargy use be provided by heat pump, waste heat mcovery or solarwater heating systems. PermitNO- Iv t v SEPARATE PERMIT REQUIRED FOR: ?Ian revme,4 , rc s sue e R Haitian cal ormsSons App o�3 st c; 1 c i iDt autncln2 Electrical araanantB Rere I arc r.- [17j Plumbing w B K r. [� Gas Piping City of Tukwila -' BUILDING DIVISION RECE!VED CITY OF TUKWIL4 AUG 1 2 2019 P R;yffT CE.vTE:R - 13 D