Loading...
HomeMy WebLinkAboutPermit M19-0135 - FIRE STATION 52 - HVAC MECHANICAL SYSTEMFIRE STATION 52 15447 65TH AVE S Apn: 3597000320 FINALED 02/03/2021 M 19-0135 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3597000320 Permit Number: 15447 65TH AVE S Issue Date: Permit Expires On: FIRE STATION 52 M19-0135 10/10/2019 4/7/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 IVY LEVANGIE 20109 144 AVE NE , WOODINVILLE, WA, 98072 JOHANSEN MECHANICAL INC. 20109 144 AVE NE , WOODINVILLE, WA, 98072 JOHANMI173PK Phone: (425) 527-1026 Phone: (425) 481-2266 Expiration Date: 2/2/2021 DESCRIPTION OF WORK: HVAC MECHANICAL SYSTEM FOR NEW FIRE STATION PER PLANS Valuation of Work: $662,215.00 Type of Work: NEW Fuel type: GAS Fees Collected: $7,171.94 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signatt L t�: i �.r'(./C 4.-{ l4 Date: /0'-/U 7 q' |hearbycertify that | have read and examined this permit and know the same tnbetrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development peln�Aandagree to_t�econditions attached tothis permit. - �8n�u Date: >U >m >c) Print Name,: /^ / vil | */� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local LI.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems- supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall beequipped with anautomatic shutoff. Automatic shutoff shall beaccomplished byinterrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (|K4C6O6-1,6U62.1) 4: Remote indicator lights are required onall above ceiling smoke detectors. (City Ordinance #2437) 5: Duct detectors shall send asupervisory signal only upon activation. (City Ordinance #Z437) 6: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. Nnwork shall commence until afire department permit has been obtained. (City Ordinance #2437)(|FC9012) 7: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. O: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ufsuch condition orviolation. 10: These plans were reviewed byInspector 511. |fyou have any questions, please call Tukwila Fire Prevention Bureau at(2O6)S7544O7. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (IO6/43I'367D). 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: Manufacturers installation instructions shall be available on the job site at the time of inspection. 14: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 15: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source ofignition isnot less than 18inches above the floor surface unwhich the equipment orappliance rests. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2UG)4J8-g35O 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST Tenant Name: 4611 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. m 1 0 Project No. Date Application Accepted: 10 g'f?0//q Date Application Expires: Jt f0/19 / (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 15447 65th Ave S Suite Number: Floor: New Tenant: LI Yes LI ..No Tukwila Fire Station 52 PROPERTY OWNER Name: City of Tukwila Address: 6300 Southcenter Blvd, Suite 1000 City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person rece.ving all project communication Name: Ivy eVangie Address: 20109 144th Ave NE City: Woodinville State WA Zip: 98072 Phone: (425) 527-1026 Fax: (425) 486-6933 Email: ivyl@johanscnrnech.com MECHANICAL CONTRACI OR INFORMATION Company Name: Johansen Mechanical, Inc. Address: 20109 144th Ave NE City: Woodinville State: WA Zip: 98072 Phone: (425) 481-2266 Fax: (425) 486-6933 Contr Reg No.: JOHANMI173PK Exp Date: 02/02/2021 Tukwila Business License No.: BUS-0994192 Valuation of project (contractor's bid price): $ 662,215 Describe the scope of work in detail: I1VAC Mechanical System for new Fire Station per plans Use: Residential: New Replacement El Commercial: New Replacement El Fuel Type: Electric ..... Gas Other: HAApplications1Forms-Applications On Line \2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater 12 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling handling unit >10,000 cfm Evaporator coole Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic incinerator — con-tin/industrial Unit Type Qty Fire damper 17 Diffuser 112 Thermostat Wood/gas stove Emergency generator Other mechanical equipment vp,p- 23 ..eA0 %‘•(‘ Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are ibased on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY '1'1-1E, LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD NG AUTHO GE Signature: Date: 08/20/2019 Print Name: 1vLeVangie Day Telephone: (425) 481-2266 Mailing Address: 20109 144th Ave NE Woodinville WA 98072 City State Zip 14:1ApplicationsWorms-Applications On Line \2016 ApplicationsNechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Receipt Number R18676 DESCRIPTIONS PermitTRAK 1 ACCOUNT I QUANTITY PAID $7,171.94 M19-0135 Address: 15447 65TH AVE S Apn: 3597000320 $7,171.94 MECHANICAL $6,896.10 PERMIT ISSUANCE BASE FEE R000.322,100.00.00 0.00 .15 PERMIT FEE R000.322.100,00.00 0.00 $54B3.73 PLAN CHECK FEE R000.322.102.00.00 0.00 $1379.22 TECHNOLOGY FEE $275.84 TECHNOLOGY FEE R000.322.900.04.00 0.00 $275.84 TOTAL FEES PAID BY RECEIPT: R18676 :I $7,171.94 p(P700 oOO, Date Paid: Wednesday, September 25, 2019 Paid By: TUKWILA CITY OF Pay Method: ACCOUNT Printed: Wednesday, September 25, 2019 2:40 1 of 1 PM SYSTEMS Permit Inspections City of Tukwila Permit Number: M19-0135 Description: FIRE STATION 52 Applied: 8/20/2019 Approved: 9/10/2019 Issued: 10/10/2019 Finaled: 2/3/2021 Status; FINALED Parent Permit: Parent Project: Details: Site Address: 15447 65TH AVE S City, State Zip Code:TUKWILA, WA 98188 Applicant: FIRE STATION 52 Owner: TUKWILA CITY OF Contractor: JOHANSEN MECHANICAL INC. HVAC MECHANICAL SYSTEM FOR NEW FIRE STATION PER PLANS WO, INSPEGTIONS SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS ROUGH -IN MECHANICAL Bill Centen Notes: PIPE_DUCT INSULATION Bill Centen Notes: MECH EQUIP EFF Bill Centen Notes: SMOKE DETECTOR TEST Bill Centen Notes: FIRE ALARM Ben Hayman Notes: 3/20/2020 AM 3/20/2020 L ROUGH -IN MECHANICAL Lee Sipe PARTIAL APPROVAL 193029 Notes: Informational pre -con. 4/24/2020 AM 4/24/2020 ROUGH -IN MECHANICAL Lee Sipe PARTIAL APPROVAL #1 Notes: P/A Approved: 1, refrigeration test. 2. OK to insulate wall mechanical level 1 & @ South Bldg. only. Printed: Tuesday, 19 October, 2021 1 of 2 rk SUPERION Permit Inspections City of Tukwila 5/15/2020 AM 5/15/2020 ROUGH -IN MECHANICAL Lee Sipe PARTIAL APPROVAL 75261 Notes: P/A Approved: L2 duct sealed OK to cover. 5/27/2020 AM 5/27/2020 ROUGH -IN MECHANICAL Darrin Graham PARTIAL 1 APPROVAL 81014 Notes: ROUGH IN MECH BUNK ROOMS 108-115/ RESTROOMS 118-121 ROOMS 129-131 ROUGH IN MECH BUNK ROOMS 108-115/ RESTROOMS 118-121 ROOMS 129-131 7/8/2020 AM 7/8/2020 ROUGH -IN MECHANICAL Lee Sipe APPROVED 55557 Notes: 8/19/2020 AM 8/19/2020 MECH EQUIP EFF Lee Sipe NOT APPROVED 423157 Notes: Missing flex & registars. 9/21/2020 9/22/2020 ROUGH -IN MECHANICAL Lee Sipe PARTIAL APPROVAL Notes: PLEASE CALL 253-267-3385 TOMOTHY. P/A Kitchen OK to cover OK to cover all ceilings. 12/8/2020 AM 1 12/8/2020 MECHANICAL FINAL Lee Sipe NOT APPROVED (253)267-3385 Notes: 1. Fire inspections must be approved before Mechanical final. 2. level 2 room N of East stairs, flex duct is not connected. 3. Exhaust system in equipment bays needs identification labeling. 10:15 1/29/2021 AM 1/29/2021 FIRE FINAL Andy Nevens APPROVED Notes: 1/29/2021 PM 1/29/2021 MECHANICAL FINALLee Sipe NOT APPROVED Needs Fire final signed Notes: Needs Fire final signed 2/2/2021 AM 2/3/2021 MECHANICAL FINAL Lee Sipe APPROVED 2532673385 Notes: Printed: Tuesday, 19 October, 2021 2 of 2 r‘k SUPERION Instructions for Electronic Forms 2015 ashington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R Revised January 20 7 Commercial Provision Chapters 1 - 5 of the 2015 ,shington State Energy Code apply to all commercial occupancies, R-2 and R-3 occupanies greater than 3 stories above graiete, and R-1 occupancy (all building heights). 0 This file, MECH15-v2.XLSM, has electronic compliance forms for mechanical provisions as defined in Sections C403, C404, C408, and Chapter 5. There are two companion files: ENVA-v2,XLSM (Sections C303, C402, Chapter 5, and Appendix A envelope requirements), LTG15-v3.XLSM (Section anelici eWe Energy Code di This form is a compliance aid and is not a substitute for the fufmrgwilpactiorAsig requirements. Users should refer to the code text and contact thd 110%1 fisi4sit.Wo WSEC code text is available for download from the NEEC websipi p Consultant http:/www.neec.net7Agy- v .. - Training Refer to the NEEC website for instruction on how to complete all of the 2015 WSEC Compliance Forms. Start-up Overvie Save Files Getting Around Select this file from the NEEC website to download to your com and if applicable, Enable Content. ei(?to Enable Macros, This file is an Excel workbook that contains multiple compliance forms and resources n Exce orksheets. Each worksheet is indicated by a tab at the bottom of the screen. If the tabs are not visible, set the View in Excel to Full Screen. You may visit each worksheet by selecting it's tab. Most calculations are automated. Cells that display informational text and the results of calculations are write -protected and cannot be edited, This file is saved in the same manner as any standard Excel file, en opening the • Some forms have two pages. Both pages are available on screen when you select the tab for the scroll bars to find the second page located below the first page. Input Cells All general project information and the date are entered once on MECH-SUM. This information is automatically replicated on all other MECH forms. Only input cells are accessible. If you try to edit a write -protected cell an error messaf password. A password IS NOT required to complete these forms. You may use the TAB f the TAB doesn't take you where you want to go, use your mouse to move around the Avoid excessively long text strings when entering information. In some cases, text space will not be visible. In most cases the text will wrap within the cell. This may force To enter the date, use this format: mm/dd/yyyy. For example, you would enter 7/1/2 Check boxes can be checked or unchecked by clicking in the box with your mouse, one in a set to be selected, '11 IENEria FOR ODE COMpaktge APPROVED extends beyond the available rt:Of the fffpitleinve. 18:or 12/21/2014. a8iO'bdoii(circles) allow only of Tukwila Drop -down lists have an arrow at the right side of the cell. Click on the arrow with yofIrBUtL.DklNGtDtVISION appropriate option. Use the delete button on your computer to clear a drop -down entry. When a form has a space for notes or explanation, click anywhere in the space to edit. Person izing You can personalize the forms with your company name, address, phone, or any other information. This is done by editing the header or footer in Excel, Adding and Removing Lines Adding MECH- FANSYS Forms Many tables, such as for listing proposed mechanical systems, have a certain number of lines available for entering data. You may need more lines to enter all your information. Where this feature is available, you can add additional lines to the table by selecting the "+" button on the right hand side of the table with your mouse. If you can't see the "+111ECEIV scroll to the right or decrease the View Zoom setting for the worksheet. CITY OF TU To remove lines that you have added, select the "-" button with your mouse. This will delete the last line of the section. You cannot remove lines that were not added; an error message will appear if you try. ED KNVILA If you add additional lines with this method, the pagination may be affected forcing the forms to carry additi0AUOng 2019 over to other pages. Be sure to submit all pages to the plans examiner. RECEIVED PERMIT CENTER A completed MECH-FANSYS form is required for each applicable fan system. One copy of this form is included in the workbook. If additional MECH-FANSYS forms are needed, select the "Insert Fan System Form" button in MECH-FANSYS- SUM or MECH-FANSYS. An added form may be deleted by selecting the."pelete Thin System" button within the added MECH-FANSYS form. Au( 2 b zu Printing All forms are set-up to be printed in letter format, with the ifickffEerGflf51914&2g144;apiagIi Heating Equipmen Schedule Form. This MECH-EQ form may be printed in either landscape or letter format, however the font is large easier to read when printed in landscape. If you are losing form details when printing, you may have a shortage of printer memory. Try printing prob individually. Only selected forms are printed. T select e or or ms, hold d. n th Ctrl d cli bs o worksheets you need. Issue the File t d S mand. 4 int e ent et, u 'e Print E Workbook. Instructions for Electronic For s 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Forms (worksheets) in a workbook may not be deleted because the file is locked. Clean Forms To print blank forms to fill out by hand, delete all of the heading information at the beginning of MECH-SUM. For each radio button group there is a button labeled "Clear." Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear button will not print. End of Instructions for Electronic Forms 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM 2015 Washington State Energy Code ComIiance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Tukwilla Fire Station 52 Date 8/1/2019 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Dept. Use Company Name: Company Address: Applicant Name: Applicant Phone: Project Description Briefly describe mechanical systems in the text box provided 0 Total Bldg Performance (TBP) This path includes an mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. J New Building LJ Building Addition LJ TenantTerient Improvement Sytem Retrofit J No System Changes Design Load Calculations E Load calculation summary ii MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules Mechanical Plans E MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECHEQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate E DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of . Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, 0 Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu 2) 111 DOAS included in project, although not required (occupancy not office, retail, education, Ei DOAS related allowances included in project: 0 Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. 0 Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. D For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions HVAC Hydronic Systems El Hydronic chilled water 1j Water -loop heat pump E] No hydronic systems El Hydronic heating water 11 Geothermal C406 Additional Efficiency Options - Mechanical C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, retum, and exhaust fans over 1 hp must have FEQ 71 and must be selected within 10% of maximum total or static pressure. C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. 0 C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, pg. 2 MECH-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Service Water Heating Systems Equipment Type (s) Ell] Hot water heating tank(s) E) Instantaneous Ej No service water systems El E Heat exchange from space heat boiler or Dedicated boiler central hot water/steam Distribution Type (s) 2 Circulation System 0 On -demand Commissioning Commissioning is required for: E Mechanical systems per C408.2 El) Service water heating systems per C408.4 If required, commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: 0 Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating. Mechanical systems commissioning not required. [11 Capacity of largest service water heating system in building does not exceed 200,000 Btu/h. Service water heating systems commissioning not required. Low Energy and Semi -Heated Spaces (Note 6 and 7 Space Type Location in Plan(s) Space(s) Served Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating ou put capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5- Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h, Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C402.1,1 Low Energy Building. lntalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h*sf Note 7- Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h*sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 21 Mechanical Permit Plans Checklist MECH-CHK Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type NA C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception NA Yes C403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery Attached Yes C403,2.2 Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater than the smallest available equipment size that exceeds the calculated loads; note exceptions taken Attached Yes C403.2.3 C403.2.3.2 C403.2.13.1 HVAC equipment performance requirements (efficiency) Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply and OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) M003 Yes C405.8 C403, 2.1 q Electric motor efficiency List all motors >_ 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated efficiency, or exception applied NA For fractional hp motors (1112 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken NA Yes C403.2.11.1 Fan power limitation For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form See Fansys For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system See Fansys Yes C403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available rnotor hp size greater than fan bhp, note exceptions taken MO.3 Yes C403.2.11.3 Fan efficiency For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is a 67, or exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency MO.3 NA C403.2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE-57) NA Yes C403.2.13 Variable flow capacity - fans For fan motors >_ 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements NA NA C403,2,3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is 5 100 tons, or exception taken NA NA C403.4 Large capacity cooling systems For buildings with a 300 tons of cooling capacity, indicate method of multi -stage or variable ° capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66/° of the total) NA NA C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements NA NA C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with >_ 1,10D gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers NA NA C403.4.2 C403.4.2.5 Large capacity boiler systems For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating bumer NA For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate turndown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) NA C403.2.13 Variable flow capacity - pumps For pump motors > 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements NA C403.2.3 Gas and oil -fired forced air fumace and unit heaters For forced air furnaces with capacity z 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss NA NA C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating or staged combustion control NA Yes C403.2.3.3 Packaged electric heating / cooling equipment Verify all packaged electric equipment with > 6,000 Bluth cooling capacity and any amount of heating is a heat pump; include in equipment schedules M003 NA C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements NA f NA C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements NA Yes C403.2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate ether dampers are Class 1 motorized, or gravity and exception taken (include leakage rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers M501 N, M501S, M502N, M502S, M502S.A NA C403.2.4.3 Retum air dampers Indicate locations of return air dampers that are integral to economizer operation; verify dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 21 Mechanical Permit Plans Checklist MECH-CHK Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: TukwillaFire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements NA NA C403.2.4.4 Zone isolation dampers For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements NA NA C403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken NA Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible NA C406.2.1 C403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply NA NA C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% NA NA C406.2.3 C403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand alone fans is >_ 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the maximum total or static efficiency NA HVAC System Controls Yes C403.2.4.1 Thermostatic controls (thermostats and humidistats) Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones M501 N, M501 S, M502N, M502S, M502S.A Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones M501 N, M501S, M502N, M502S, M502S.A If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating M501 N, M501 S, M502N, M502S, M502S.A NA C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lock -out temperature set to 40°F or less NA Yes C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling NA C403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans NA Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling NA NA C403.2.4.2 C403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken NA NA C403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy NA C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust NA C403.2.4.3 Stairway and shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) NA NA C403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken NA NA C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied NA NA C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F NA NA C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing NA NA C403.2.4.9 Group R1 hotel /motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 21 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State EnergyCode Compliance Forrns for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project T : Tukwilla FireHreStation 52 Date 20 9 The following information is necessary to check a permit application for compliance with the mechanical systems nd eqsipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable y ,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.10 C403.2.4.11 Group R2 / R3 dwelling units, Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken NA Yes C403.2.6 403.2.11.4 Ventilation Indicate method of ventilation air delivery (natural or mechanical) for each zone M501N, M501S, M502N, M502S, M502S.A If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum reqUired volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken M501N, M5015, M502N, M502S, M502S.A If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces NA NA C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or the system has airside economizer or automatic modulating OSA damper; indicate OSA controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception NA NA 0403.2.6.3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or altemate means provided to automatically reduce OSA when space is partially occupied NA NA C403.2.6,4 C403.2.6.4.1 Enclosed loading dock ventilation For enclosed ading docks, indicate ventilation 1 exhaust system method of activation detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) NA NA C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken NA NA C403.2.7.1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust NA For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that wouki otherwise be exhausted) NA NA CO3.2.1 03.2,7,2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements NA Yes C4 Variable flow capacity - HVAC system fans For HVAC fan motors 2 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken NA NA C403.3.1 DX air handler variable cooling control (Under Integrated Economizer) For DX air handlers with economizer and cooling capacity 2 65,000 Btuth, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load NA Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) NA Yes C4012.11.5 Fan airflow control For DX air handling units with cooling capacity a 65,000 Btu/h and evaporative and chilled water air handling units with fan a 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) NA For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is s 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only NA For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is 5 50% of full speed drawing 5 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken NA C403.2.4.12 DDC system capabilities Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table C403.2.4.12.1 Identify all DDC system input / output control points; indicate capability for trending and graphical dispity Ducting Sy te s Yes C4 03.2.8,1 C403.2.8.3 Duct construction Indicate on plans that all ductwork is constructed and sealed per IMC M001 For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC M001 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 8 of 21 Mechanical Permit Plans Checklist MECH-CHK Washinaton State Enerov Code Compliance Forms for Commercial Buildings incIudng R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Departrnent Notes Yes ‘4403.2,8.3 Duct pressure classifications Identify Iocation of low, medium and high pressure ductwork on plans M501 N, M501S, M502N, M502S, M502S.A NA C403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 9 of 21 Mechanical Permit Plans Checklist MECH-CHK ashington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 52 Date 8 / 1 /2 019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes /%C403.2.8.1 Yes y C403.2.8.2 Duct insulation For supply and return ductwork located in unconditioned space or outdoors, indicate R-value of insulation on ductwork on plans; identify climate zone; note exceptions taken M001 For supply ductwork located in conditioned space, identify if design supply temperature is < 55°F or> 105°F and indicate R-value of insulation on this ductwork on plans; note exception taken M001 For OSA ductwork, shafts and plenums, indicate R-value of insulation on these elements on plans per Table C402.1.3 for steel -framed walls; note exception taken M001 _ Piping Systems Yes ✓ C403.2.9 Piping insulation p 9 Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken M001 Yes C403.2.9:1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping .lans NA Economizers NA C403.3 Air economizer required Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls NA Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of air economizer; indicate on plans eligible exception(s) taken and measures to comply with exception(s) NA NA C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load NA NA C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation NA NA C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA for cooling NA NA C403.3.1 C403.3.3.2 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F NA For systems with cooling capacity a 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NA NA C403.3.3.3 Air economizer high limit controls Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 NA NA C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA temperatures NA NA C403.3.42 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in watereconomizer system do not exceed pressure drop limit NA NA C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity z 65,000 Bluth, refer to HVAC System Controls for requirements NA NA C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity z 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults NA Systems Requiring Energy Recovery NA C403.5.1 Energy recovery (ER) - ventilation / exhaust systems For systems with design OSA > 5,000 cfm, or design supply air cfm and V. OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations NA For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and ToOSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations NA -^ Indicate ER rated effectiveness that increases OSA enthalpy by z 50% based on delta between OSA and retum air enthalpies at design conditions NA NA C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust> 5,000 cfm, indicate method of energy recovery used to pre -condition laboratory make-up air; ER effectiveness (min 25°F); or alternative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) NA NA C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken NA Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by a 36'F NA NA C403.5.2 Energy recovery - steam condensate systems For buildings with on -site steam heating systems, indicate condensate water ER NA For buildings that use off -site generated steam where condensate is not retumed to the source, indicate on -site condensate water ER NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 10 of 21 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provis;ons. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have >_ 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) NA _. For buildings with 2 40,000 sf conditioned floor area and with 2 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy far service water heating and also for space heating, or dehumidification reheating NA NA C403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 MLA, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). NA Hydronic System Controls C403.2.13 C403.4.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors 2 7.5 hp, indicate method of variable flow control (VSP or equivalent method that requires 2 30% design wattage at 50% design fluid flow); no exception taken NA Identify whether hydronic coils have DDC controls and associated manner " pump speed control (differential pressure, zone hydronic demand, etc) NA C403.2.5 C403.4.2.4 Hydronic system setback and part load controls For boilers that provide building heating, indicate controls that pro '.e heating water temperature setback based on outdoor temperature NA For heating and chilled water systems 2 300,000 Btu/h, in•' ate systems are configured to automatically reset supply water temperature based u..n demand; or exception taken. If system pump motor hp 2 3 hp, also indicate con, w s automatically reduce flow by 2 50%. NA For chilled water systems (2 300,000 Btu/h, p p motor hp 2 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or sit ed pumps in chilled water system and heat rejection loop that reduce pump flow so atone control valve is nearly wide open, or to maintain a minimum differential pre re; or exception taken NA C403.4.2 Boiler sequencing Indicate automatic controls th equence operation of multiple boilers NA C403.4.6 Hot gas bypass limitation For cooling equipmentwit of gas bypass, provide either multiple step unloading or continuous capacity m ulation; indicate bypass capacity per Table C403.4.6 NA NA C403.4.2.2 Two -pipe changeover systems Indicate changeov deadband (min 15°F), heating / cooling mode scheduling and changeover to erature range (limit 30°F) NA C403.4.2.6 Chiller / boiler plant pump isolation Indicate co ols are configured to automatically reduce overall plant flow and shut-off flow throug ' dividuat chillers and boilers when not in use NA C403.2.13.1. I C403.4.3.1_1 C403.4.3.1.2 Heat rejection equipment - variable flow control For oling towers with fan motors_ 7.5 hp, indicate VSD and method to adjustfan speed djusted based on leaving fluid temperature or condenser temperature / pressure of heat rejection device) NA For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison NA NA C403.4.3.3 Heat rejecti equipment - cooling t er flow turndown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel NA NA C403.4.2.3.1 W r loop heat pump - adband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken NA NA C403.4 .2.1 Water loop heat pump - he t Zone 4lection equipment, Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method used to limit system heat loss when heat rejection is not needed NA NA C403.4.2.3.2.2 Water loop heat pump - Zone rejectionheat 5 equipment. For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling tower and heat pump loop NA NA C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power > 10 hp, indicate 2-way isolation valves on each heat pump and variable flow system control NA Dedicated Outdoor Air Systems (DOAS) - ©ptional through 6/30/16, Prescriptive 7/1/2016 C403.6 C403.6,3 Dedicated outdoor air systems For buildings with office, retail, education, library and fire station spaces, identify these spaces on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 rnay not utilize exceptions) M501 N, M501 S, M502N, M502S, M502S.A NA C403.6.1 Energy recovery ventilation with DOAS For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting calculations. Indicate ER rated effectiveness that increases OSA enthalpy by 2 50% based on delta between OSA and retum air enthalpies at design conditions. M002 4IA C403.6.2 Heating / cooling system controls with DOAS Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is configured to turn down, when there is no call for heating or cooling in the zone they serve M002 If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 11 of 21 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provis':ons. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 NA Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) NA C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 M501 N, M501 S, M502N, M502S, M502S.A Multiple Zone Air Systems NA C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV NA NA C403.4.4 VAV systems serving multiple zones Provide equipment schedules on plans or MECH-EQ Form that list all VAV air terminals and types NA For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans NA NA C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling NA NA C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct NA NA C403.4.1.1 C403.4.12 VAV system static pressure sensors - sensors and DDC set points Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is <_ 1.2 inch w.g. NA For systems with zone level DDC, indicate controls are configured to monitor zone damper positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic NA NA C403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken NA NA C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken NA Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions NA C403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with all related economizer requirements per C403.3 (without economizer exceptions) NA NA C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display NA NA C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) NA NA C403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions NA NA C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 NA NA C403.7, Item 6 Interior / exterior zone design supply air temperature Verify that VAV terminals serving interior cooling driven loads are sized per design supply air temperature that is 5°F higher than VAV terminals serving exterior zones NA NA C403.7, Item 7 Maximum air terminal inlet velocity Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EQ foram; indicate air terminal inlet velocity does not exceed 900 fpm NA NA C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 NA NA C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is 5 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system NA NA C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; indicate DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating, low cooling, or ventilation only is 5 66% of peak design air flow or provide supporting documentation for applied exception NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 12 of 21 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: TukwillaFire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes ,no,na ) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.7, Item 11 Application of single duct unanflsfan-powered terminal Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units NA NA C403.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction NA NA C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density >_ 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by 2 5°F NA NA C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling bads > 5 W/sf, indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 NA NA C403.7, Item 15 Central plant efficiency Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant NA If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas -fired boiler(s) with thermal efficiency > 90%, air -to -water heat pumps, or heat recovery chillers NA If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency That exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is <_ 20% of total plant capacity, or provide thermal storage sized fors 20% of total plant capacity NA NA C403.7, Item 16 Fault detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system NA HVAC Equipment Energy Use Metering C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception NA Documentation and System Specific Requirement To Support Commissioning Yes C408.2 Scope of mechanical systems commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; M001 For buildings with >_ 240,000 Btu/h total output cooling capacity or >_ 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception M001 Yes C403.2.10 C408.1.1 C408.1.2 C408,1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; M001 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including; narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); M001 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. M001 Yes C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions M001 Yes C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing M001 Yes C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps M001 Yes C408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M001 Project Close Out Documentation Yes C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations M001 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 13 of 21 Service Water Heating Permit Plans Checklist SWH-CHK Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Si ing, Performance and Type YesC404.2 SWH equipment type and efficiency Provide equipment schedule on plans indicating type and capacity; indicate efficiency complies with required federal standard MO.2 NA C404.2.1 High input -rated SWH systems For individual SWH equipment serving an entire building with a 1,000,000 Btu/h capacity, indicate thermal efficiency 2 90%; or exception taken NA For buildings with aggregate capacity of all SHINequipment z 1,000,000 Btu/h (exclude < 100,000 Btu/h equipment from threshold calculation), indicate average capacity weighted thermal efficiency 2 90%; or exception taken NA NA If applying Exception 1 for site -solar or site -recovered energy, provide calculations and source of annual service water heating energy use estimate C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply and discharge Spec C404.5 Insulation under electric water heater For electric water heaters located in unconditioned spaces or on concrete floors, indicate R-10 insulation under equipment Spec Piping Systems Yes/ C404.6 Insulation of piping Indicate thickness of piping insulation on plans per Table C403.2.9; verify insulation is provided - from the water heater to the final fixture in a line, from the inlet / outlet piping at water heater to heat trap (up to 8 feet), and on piping that is heat traced; note exceptions taken MO.1 NA C404.3 Efficient SWH supply piping Indicate method of compliance on plans for all piping runs connecting service hot water source to hot water fixture (maximum pipe length or maximum pipe volume method per Table C404.3.1); provide calculations for all piping runs documenting the total length and / or volume NA Service Water Heating System Controls Yes ✓C404.7.1 C404.8 Heated -water circulating systems For circulation systems with dedicated retum piping, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand and when the desired water temperature is met Spec For circulation systems with cold water supply piping serving as the retum, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand, or when temperature of water entering the cold water supply pipe is >_ 104°F Spec — NA C404.7.2 Heat trace system controls For heat trace systems provided to maintain temperature of service hot water in piping, indicate controls are configured to de -energize system when there is no demand for hot water and when the desired water temperature is met NA NA C404.7.3 Controls for hot water storage For systems with separate water heater and storage tank, indicate controls are configured to limit operation time of pump after end of heating cycle to <_ 5 minutes NA NA C403.2.13 C403.4.2.7 Variable flow control - pumps For SWH, pool / spa and pressure boosting pump motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires 2 30% design wattage at 50% design fluid flow); note exception taken NA Identify basis of pump speed control (differential or static pressure setpoint, pressure, zone bad demand, etc) NA Pools and Permanent Spas - Equipment and Controls (Sections are under C404.11) NA C404.10.1 Pool heating equipment efficiency Provide equipment schedule on plans indicating type and capacity for all pool heating equipment; indicate efficiency complies with required federal standard; for heat pump water heaters indicate COP 2 4 NA C403.2.13 VNA pumps le flow control Refer to Service Water Heating System Controls NA NA C404.10.1 C404,10.2 Pool heater on !off controls Indicate automatic on / off control based on scheduling and readily accessible on / off switch on heater that operates independent of thermostat setting; note exceptions taken NA NA 404.10.3 Pool covers For all pools and in -ground permanent spas, indicate a vapor retardant cover on plans NA For all pools and in ground spas heated to > 90 F indicate cover shall include insulation z R- 12 NA NA C404.10.3 Pool assembly insulation For all pools and in -ground spas heated to > 90°F, Indicate on plans that sides and bottom are provided with insulation >_ R-12 NA NA C404.12 Energy consumption of portable spas Indicate portable spa complies with Association of Pool and Spa Professionals APSP-14 NA 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 14 of 21 Energy Recovery (ER) Systems - Service Water Heating and Pool Systems NA C404.10.4 (Section under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or permanent spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken NA -. Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by a 36°F NA NA C403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have a 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water NA For buildings with a 40,000 sf conditioned floor area and with 2 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water NA NA C403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and > 1,500,000 Btu/h of heat rejection capacity and design SWH load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). NA NA C404.10 Drain water heat recovery units For systems incorporating drain water ER, indicate system design complies with CSA B55.2 (or CSA 55.1 for Group R); indicate potable waterside pressure loss at design flow is < 10 psi NA Service Water Heating Energy Use Metering NA C404.9 SWH energy usage in dwelling units For Group R-2 multi -family buildings with central SWH systems, provide metering of hot water energy usage per dwelling unit; indicate metering and data reporting method NA NA C409,3.2 SWH equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, with total SWH equipment capacity a 50 kW (a 170,600 Btu/h), verily energy use metering of all SWH equipment will be provided per C409 NA Additional Efficiency Package Option, Reduced Energy Use In Service Water Heating - Must comply with both provisions to be eligible NA C406.7.1 Eligible building type To comply with additional efficiency package option, verify that a 90% of the conditioned floor area of the building is one or more of the occupancies identified in this section, OR; NA Provide whole building energy analysis per C407 that demonstrates the SWH load in the building is 2 10% of total building energy loads NA NA C406.7.2 C403.5.4 Load fraction To comply with additional efficiency package option, provide documentation that verifies a 60% of building annual SWH energy is provided by high efficiency sources (heat pump water heater with COP a 3, waste heat recovery, solar water -healing system); NA For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h (per C403.5.4); provide documentation that verifies 2 100% of building annual SWH energy is provided by condenser energy recovery or other high efficiency source NA Documentation and Specific System Requirements to Supporting Commissioning Ye C408.4 Scope of service water heating systems commissioning Indicate that all SWH equipment and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned;+D7 — -- Spec For buildings where the largest SWH system has ? 200,000 Btu/h total output capacity, indicate that all SWH systems regardless of individual capacity are required to be commissioned. Spec NA C408.4.1.3 Scope of pool and permanent spa systems commissioning Indicate that all pool and permanent spa water heating systems regardless of individual capacity are required to be commissioned; NA Indicate that energy recovery equipment that heats pool water regardless of capacity is required to be commissioned; NA Identify all pool heating and' energy recovery equipment and controls that the WSEC defines as being capable of and / or configured to perform specific functions. NA YesVC408,1.1 C404.13 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C40B is required for all applicable service water heating systems; MO.2 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activites, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); MO.1 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. M001 Yes C408.4.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M002, M003 Project Close Out Documentation Yes r �/ / C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all SWH components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forrns and calculations M001 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & Project Title: Tukwilla Fire Station 52 R3 over 3 stories and all R1 Revised January 2017 Date 8/1/2019 All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be applied to and additional information as noted below. For Building Dept. Use Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year- round design cooling loads from lights and equipment less than 5 watts per square foot. System ID Lighting + Equipment Loads (W/sf) Exp 2 Single zone unitary or package systems with dehumidification that affect other systems such that air economizer would increase energy consumption. System ID Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. System ID Exp 4 Equipment that provides hydronic chilled water for chilled beams and chilled ceiling systems that is served by a water economizer system per C403.3.4 in lieu of air economizer. System ID Exp 5 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15%. better than WSEC required minimum efficiency. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Exp 6 Cooling equipment serving Group R occupancies, Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System ID Equipment Location Cooling Capacity (Btu/h) Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor unit shall be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System ID Cooling Capacity (Btu/h) VRF 228,000 Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied heat pumps. System ID SEER, EER, & IEER Exp 9 Cooling equipment with energy recovery. Spaces served shall have year-round design cooling loads from lights and equipment greater than 5 watts per square foot. Energy recovery system shall utilize recovered energy for on -site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of recovered energy used for on -site heating purposes is equivalent to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Lighting + Equipment Loads (W/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions, cont. MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Date 8/1/2019 Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED Exp 10 Cooling equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit for this exception is 240,000 Btufh cooling capacity or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a- Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency.. Option b - Waterside economizer required. Cooling equipment efficiency shall be 5% better than the WSEC required minimum efficiency. Option c - Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127. System ID Compliance Option Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 240 kBtu/h): Alternate Exp 10 Capacity Limit: ECONOMIZER EXCEPTIONS - MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT C503.4 Exp 1 Pre -approved design alternative to full compliance with air economizer requirement. An alternative for mechanical system alterations where existing building constraints make full compliance with air economizer requirement impractical. Provide calculations to the code official that demonstrate the proposed altemate design strategy provides similar energy savings to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Alt. Strate y ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5% of required building air economizer capacity, whichever is greater. Cooling equipment efficiency shall be 15% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 72,000 Btulh): Alternate C503.4 Exp 2 Capacity Limit: C503.4 Equipment that provides hydronic chilled water for chilled water terminal Exp 3 units. Equipment part load cooling efficiency (IPLV) shall be better than WSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the building capacity total, System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 480,000 Btu/h): Alternate C503.4 Exp 3 Capacity Limit: Table Compliance Options for alteration or replacement of existing C503.4 mechanical cooling equipment per Table C503.4. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Option b - Option c - Option d - Any new or replacement equipment Replacement equipment of same type with same or smaller cooling output capacity. Replacement equipment of same type with large cooling output capacity. New equipment added to existing system or replacement equipment that is different than existing being replaced. System ID Equipment Type Compliance Path 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 2015 Washington State EnergyCode Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January2017 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RHRV CV Rootop Heat Recovery Unit 4.6 No Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list ail fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance MEOH-FANSYS 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. For Building Dept. Use Fan System ID System Supply Fan Speed Control CV Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1, Exception 1 Compliance Option ' Brake HP Compliance is based upon either the fan motor nameplate horse power (Option 1), the fan brake horsepower (Option 2), or C403.7 high efficieny VAV fan brake horsepower (10% less than Option 2). The bhp calculation provides adjustments for special equipment per Table C403.2.11.1(2). Fan System Supply CFM Total 1,500 In Fan Equipment Schedule below, provide maximum design supply airflow rate (CFM) of all supply fans serving the conditioned space in Fan Equipment Schedule below. Fan System CFM Total is the supply airflow of the central air handler at peak design conditions. Additional volumetric air flow provided at zone fan terminals, booster fans, or through induction is not included in the supply CFM total. However, the fan power of this equipment is included in the HP and BHP calculations. Fan System Supply CFM Total is automatically calculated by the form. Fan Equipment Schedule Fan ID and Location Fan Type Quantity of Fan Type Total CFM (Note 1) Total Nameplate HP (Note 2) Total BHP (Note 3) Supply 1 1,500 2 1.1 Exhaust 1 1,450 2 Note 1 - Total CFM is the maximum CFM of the listed fan(s) when operating at peak design operating conditions. Note 2 - Total namplate hp of the listed fan(s). Note 3 - Total brake horsepower (bhp) of the listed fan(s) at peak design operating conditions. Not required if Nameplate HP compliance option chosen. Compliance Message: Total Proposed: Total Allowance: 4.0 2.1 1.7 2.2 COMPLIES Brake Horsepower Allowance Adjustments Device Type Description and Location CFM thorough this device (CFMD) Assigned Pressure Drop, PD in w.c. (Note 6) Calculated Pressure Drop, PD in w.c. (Note 7) Adjustment, A in bhp (Note 8) Fully ducted return and/or exhaust Exhaust Ductwork 1,500 0.5 0.182 Particulate filtration: MERV 13 . 15 Supply Fan 1,500 0.9 0.327 Energy recovery device, other than coil (Notes 4 & 5) Energy Wheel 1,500 0.8 0.290 Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): 0.80 the device. Note 5 - Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply divided by the enthaply difference between the outdoor air and return air at design conditions. Note 6 - Assigned pressure drop (PD) adjustment per Table C403.2.11,1(2). Note 7 - Pressure drop (PD) adjustment shall be calculated per the applicable method defined in Table C403.2.11.1(2) based on specific system conditions. Note 8 - A = PD CFMD/4131 where A is the allowed system brake horse power adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 General Instructions: A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system. Enter CFM and brake horsepower (bhp) of each fan at peak design conditions and the nameplate horsepower (hp). Include supply, return and relief fans, exhaust and exhaust hood fans (>1 hp), booster fans and fans included as part of make-up air units, dedicated outside air systems (DOAS), energy recovery ventilators (ERV), and series fan -powered terminal equipment. B. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. C. Fans not directly associated with the delivery and removal of conditioned air, such as condenser fans, do not need to be included in the fan power total. D. Fan power calculations are not required for non -central air HVAC systems such as 4-pipe fan coils and variable refrigerant flow (VRF) systems unless individual fan systems are greater than 5hp. E. In the Brake Horsepower Allowance Adjustments table, if a Device Type is selected that has an Assigned Pressure Drop, this value will auto fill into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write -protected. If the Device Type requires a Calculated Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write -protected. F. Refer to FAQ section of MECH-FANSYS-DOC for additional instructions. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Fan Power Allowance Adjustment Factors 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH-FANSYS-DOC Revised January 2017 TABLE C403.2.11.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT Device Adjustment Credits Fully ducted return and/or exhaust air systems 0.5 inch w.c. (2.15 inches w.c. for laboratory and vivarium systems) Return and/or exhaust air flow control devices 0.5 inch w.c. Exhaust filters, scrubbers, or other exhaust treatment The pressure drop of device calculated at fan system design condition Particulate filtration credit: MERV 9 - 12 0.5 inch w.c. Particulate filtration credit: MERV 13 - 15 0.9 inch W.C. Particulate filtration credit: MERV 16 and greater and electronically enhanced filters Pressure drop calculated at 2x clean filter pressure drop at fan system design condition Carbon and other gas -phase air cleaners Clean filter pressure drop at fan system design condition Biosafety cabinet Pressure drop of device at fan system design condition Energy recovery device, other than coil runaround loop (2.2 x energy recovery effectiveness) — 0.5 inch w.c. for each airstream Coil runaround loop 0.6 inch we, for each airstream Evaporative humidifier/cooler in series with another cooling coil Pressure drop of device at fan system design conditions Sound attenuation section (fans serving spaces with design background noise goals below NC35) 0.15 inch w.c. Exhaust system serving fume hoods 0.35 inch w.c. Laboratory and vivarium exhaust systems in high-rise buildings 0.25 inch w.c./100 feet of vertical duct exceeding 75 feet Deductions Systems without central cooling device -0.5 inch w.c. Systems without central heating device -0.3 inch w.c. Systems with central electric resistance heat -0.2 inch we, w.c..= water column. For Si: 1 inch w.c..= 249 Pa, 1 inch.= 25.4 mm. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Design Load Calculation Summary MECH-LOAD-CALC 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all RRevised January 2017 Project Title: Tukwilla Fire Station 52 Date 8/1/2019 The following information shall be included in the load calculation program summary submitted with the permit documents. If a load calculation summary is not available, provide the required information below. For Building Dept. Use Equip, ID Area(s) Served Heating Design Load in Btu/h (Note 1) Cooling Design Load in Btu/h (Note 1) Calculation Method (Note 2) Notes See Attached HAP Program Output. 1 Note 1 - Design load shall account for the building envelope, lighting, ventilation and occupancy loads of the space(s) served by the mechanical system. Heating and cooling loads shall be adjusted to account for load reduction achieved by an energy recovery .system, if applicable. Note 2 - Computer load calculation program, worksheet (identify source), or equivalent computation procedure in accordance with ASHRAE Standard 183. 1... li 1. GREENBUSCH. G f4C)U , I NC. 8/02/19 Tukwila Fire Station 52 Load Calculations Index Location (Equipment) FILE ZONE 01-BC BUNK IDU-1.1 Reviewed an Approve ZONE 02-BUNK IDU-1.2 4� /� ZONE 03-BUNK IDU-1.3 for Substa 4. I Compliance ZONE 04-CAPT BUNK IDU-1.4 By BH sultants 4 ZONE 05-STORAGE RHRV S ZONE 06-CORRIDOR IDU-1.9 ZONE 07-BUNK IDU-1.5 Date ZONE 08-BUNK R110 IDU-1.6 ZONE 09-BUNK R109 IDU-1.7 ZONE 10-BUNK R108 IDU-1.8 ZONE 11-GEAR/LAUND RHRV, EUH-7,8 ZONE 12-CORRIDOR IDU-1.10 ZONE 13-ENTRY IDU-1.11 ZONE 14-PHYS TRAIN IDU-1.12 ZONE 15-DECON EUH-1 ZONE 16-EMS DRY EUH-2 ZONE 17-EMS EUH-3,4 ZONE 18- SCBA EUH-5 ZONE 19- APP BAY UH-1,2,3,4 ZONE 20 - GREAT RM IDU-2.3 ZONE 21- STATION OFFICE IDU-2.2 ZONE 22 - CAPT OFFICE IDU-2.1 ZONE 23 - LUNCH IDU-2.13 ZONE 24 - BC R205 IDU-2.7 fECE>ivEn ZONE 25 - A. CHIEF R204 IDU-2.8 CITY OF T UKWILA ZONE 26 - A. CHIEF R203 IDU-2.9 ZONE 27 - EOC / TRAINING IDU-2.6 AUG 20 2019 ZONE 28 - ADMIN IDU-2.11 ZONE 29 - CHIEF IDU-2.10 PERMIT CENTER ZONE 30 - CONFERENCE IDU-2.12 Pages VIEWED FOR CO E COMPLIANCE 9APPROVED riSEP 10 2019 12 day of Tukwila BUIOING DIVISION ZONE 31- SHOP EUH-6 ZONE 32 — COMM ODU-3/IDU-2.13 ZONE 33 — LEVEL 2 SHELL IDU-2.4, IDU-2.5 RECEIVED ft0135' 16 17 18 AUG 2 6 2019 19 20 BHC Consultants, LLC21 22 23 24 25 26 27 28 29 30 31 32 33 p) 206.378.0569 toll free:855.476,2874 f) 206.378.0641 www,greenbusch.com 1900 W. Nickerson St., Suite 201 Seattle, WA 98119 Franklin, OH 1 La Quinta, CA Iro Air System Design Load Summary for ZONE 01-BC BUNK IDU-1.1 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/201 09:43AIV DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 27 ft2 - - 27 ft2 - - Wall Transmission 284 ft2 - - 284 ft2 392 - Roof Transmission 0 ft2 - - 0 ft2 0 - Window Transmission 27 ft2 - - 27 ft2 439 - Skylight Transmission 0 ft2 - - 0 ft2 0 - Door Loads 0 ft2 - - 0 ft2 0 .. Floor Transmission 87 ft2 - - 87 ft2 126 - Partitions 0 ft2 - - 0 ft2 0 - Ceiling 0 ft2 - - 0 ft2 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 >> Total Zone Loads - - - - 958 0 Zone Conditioning - - - - 927 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 45 CFM 0 - Ventilation Load - - - 30 CFM 1300 0 Supply Fan Load - , - - 45 CFM 0 - Space Fan Coil Fans - - .. - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - >> Total System Loads - - - - 2226 0 Central Heating Coil - - - - 2226 - >> Total Conditioning - - - - 2226 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 1 of 33 Air System Design Load Summary for ZONE 02-BUNK IDU-1.2 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/201 09:43AN DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB 1 WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 27 ft2 - - 27 ft2 - - Wall Transmission 109 ft2 - - 109 ft2 151 - Roof Transmission 0 ft2 - - 0 ft2 0 - Window Transmission 27 ft2 - - 27 ft2 439 - Skylight Transmission 0 ft2 - - 0 ft2 0 - Door Loads 0 ft2 - - 0 ft2 0 - Floor Transmission 87 ft2 - - 87 ft2 99 - Partitions 0 ft2 - - 0 ft2 0 - Ceiling 0 ft2 - - 0 ft2 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 Electric Equipment - - - 0 0 i People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 » Total Zone Loads - - - - 689 0 Zone Conditioning - - - - 682 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - .. 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 32 CFM 0 - Ventilation Load - - - 30 CFM 1300 0 Supply Fan Load - - - 32 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - >> Total System Loads - - - - 1982 0 Central Heating Coil - - - - 1982 - » Total Conditioning - - - - 1982 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 2 of 33 Air System Design Load Summary for ZONE 03-BUNK IDU-1.3 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/201, 09:43AN DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 27 ft' - - 27 ft' - - Wall Transmission 109 ft2 - - 109 ft' 151 - Roof Transmission 0 ft' - - 0 ft' 0 Window Transmission 27 ft' - - 27 ft2 439 i Skylight Transmission 0 ft2 - - 0 ft2 0 - Door Loads 0 ft2 - - 0 ft' 0 - Floor Transmission 86 ft' - - 86 ft' 99 - Partitions 0 ft' - - 0 ft' 0 - Ceiling 0 ft2 - - ft 0 ' 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 » Total Zone Loads - - - - 689 0 Zone Conditioning - - - - 653 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 32 CFM 0 - Ventilation Load - - - 30 CFM 1295 0 Supply Fan Load - - - 32 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - >> Total System Loads - - - - 1948 0 Central Heating Coil - - - - 1948 - >> Total Conditioning - - - - 1948 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 3 of 33 Air System Design Load Summary for ZONE 04-CAPT BUNK IDU-1.4 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/2019 09:43A1V DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 9.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 27 ft2 - 27 ft2 - - Wall Transmission 109 ft2 109 ft2 151 - Roof Transmission 0 ft2 0 ft2 0 - Window Transmission 27 ft2 27 ft2 439 - Skylight Transmission 0 ft 0 ft2 0 `' Door Loads 0 ft2 0 ft2 0 - Floor Transmission 86 ft2 86 ft2 99 - Partitions 0 ft2 0 ft2 0 - Ceiling 0 ft2 0 ft2 0 - Overhead Lighting - 0 0 - Task Lighting - 0 0 - Electric Equipment - 0 0 - People - 0 Infiltration - 0 0 Miscellaneous - - 0 0 Safety Factor 0% / 0% 0% 0 0 » Total Zone Loads - - 689 Zone Conditioning - 653 Pienum Wall Load 0% 0 0 - Plenum Roof Load 0% 0 0 - Plenum Lighting Load 0% 0 0 - Return Fan Load - 32 CFM 0 - Ventilation Load - 30 CFM 1295 0 Supply Fan Load - 32 CFM 0 - Space Fan Coil Fans - - 0 - Duct Heat Gain / Loss 0% 0% 0 - >> Total System Loads - - 1948 0 Central Heating Coil - 1948 - >> Total Conditioning - - - 1948 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 4 of 33 i• Air System Design Load Summary for ZONE 05-STORAGE RHRV Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc, 08/02/2019 09:43AM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' - - 0 ft2 - . Wall Transmission 364 ft" - - 364 ft2 419 - Roof Transmission 0 ft' - - 0 ft' 0 - Window Transmission 0 ft" - - 0 ft2 0 - Skylight Transmission 0 ft' - - 0 ft' 0 - Door Loads 0 ft2 - .. 0 ft2 0 - Floor Transmission 194 ft' - - 194 ft2 197 - Partitions 0 ft" - - 0 ft' 0 - Ceiling 0 ft - - 0 ft' 0 . Overhead Lighting - - - 0 0 .. Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 0% / 0% - - 0% 0 0 >> Total Zone Loads • - - - 617 Zone Conditioning - - - - 674 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - _ 150 CFM 0 - Ventilation Load - - - 150 CFM 5575 0 Supply Fan Load - - - 150 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - >> Total System Loads - - - - 6249 0 Central Heating Coil - - - - 6249 _ » Total Conditioning - - - - 6249 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 5 of 33 Air System Design Load Summary for ZONE 06-CORRIDOR IDU-1.9 Project Name: u01zO92 FS52Tukwila Prepared by: The Greenbusch Group, Inc. DESIGN COOLING DESIGN HEATING COOLING DATA xT Aug1*no comuwGOAoo/wB 84s^p/64.8^p HEATING DATA «rDES *To HsAnwooAoa/vva 23.0^p/19.2^p ZONE LOADS Details Sensible (a7umr) Latent (eTumr) Details Sensible (eTu/nr) Latent (orumr) Window 8Skylight Solar Loads 08" D - 0ft2 - - Wall Transmission 147(t2 256 ' 147ft2 237 - Roof Transmission on^ O' OfP o ' Window Transmission 0*` O ' ofp O Skylight Transmission ofp o ' OoP o ' opo,l-o*dv 21 *` 40 21 f12 381 Floor Transmission 151382 0 ' 1513fp 474 ' Partitions O*" O - 00" V ' Ceiling U*` 0 ' 002 0 ovomaau unmmo 817vv 27e7 ' o O ' Task Lighting 0w n �0 o ' Electric Equipment uw o - 0 u - People G 3150 5e50 V O V |nhxmdvn ' n o ' o o Miscellaneous ' o o o o Safety Factor 0%/0% o 0 U% o o *^ Total Zone Loads ' aoae n000 ' 1092 o Zone Conditioning - 6237 5550 ' 1083 U Plenum Wall Load O% O ' O 0 - Plenum Roof Load om n ' n n Plenum Lighting Load o% o ' o n Return Fan Load 327CFm o ' 327oFm o ' Ventilation Load 240CFm 1819 '5394 240CFw 12414 o Supply Fan Load 327CFM 0 ' 327CFm U ' Space Fan Coil Fans ' O ' ' V - Duct Heat Gain /Loss 0% O o% 0 >° Total System Loads - 000* 156 ' 13497 o Central Cooling Coil ' 8056 156 ' U O Central Heating Coil - V ' 13497 ' >> Total Conditioning ' 8056 15$ ' 13497 $ mev; Positive values are c|gloads Negative values are »»nloads Positive values are o*gloads Negative values are meloads Hourly Analysis Program 5.11 Page oof 33 Air System Design Load Summary for ZONE 07-BUNK !DU-1.5 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/2019 09:43Atv DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WB 82.5 °F / 63.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU(hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 27 ft' 1410 - 27 ft - - Wall Transmission 102 ft' 202 - 102 ft' 164 - Roof Transmission 125 ft' 148 - 125 ft' 161 - Window Transmission 27 ft' 33 - 27 ft2 513 - Skylight Transmission 0 ft' 0 - ft0 ' 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 70 ft' 0 - 70 ft2 99 - Partitions 0 ft? 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 Overhead Lighting 38 W 129 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 1 295 455 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 2216 455 - 937 0 Zone Conditioning - 2098 455 - 947 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 118 CFM 0 - 118 CFM 0 - Ventilation Load 30 CFM 158 -421 30 CFM 1544 0 Supply Fan Load 118 CFM 0 - 118 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 _ >> Total System Loads - 2256 34 • 2491 0 Central Cooling Coil - 2256 34 - 0 0 Central Heating Coil - 0 - - 2491 - >> Total Conditioning - 2256 34 - 2491 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 7 of 33 ~ Air System Design Load Summary for ZONE 08-BUNK R1 10 IDU~1.6 Project Name: 2017.O92FS52Tukwila Prepared by: The Greenbusch Group, Inc. O80c/2O1V DESIGN COOLING DESIGN HEATING COOLING DATA xT Sop1*oo coouwmowoo/vvB ou.s^p/Vx.o^p HEATING DATA xTDES *To HEATING oAoe/wo 23.0^p/19.2~p ZONE LOADS Details Sensible (BTU/or) Latent (oTumr) Details Sensible (aTu/nr) Latent (oTuAmr) Window & Skylight Solar Loads 27h2 1410 - 27ft' - ' Wall Transmission 105b" 207 - 105ft2 169 - Roof Transmission ofP O' oMP 0 ' Window Transmission urnp nn ' urnP 513 - Skylight Transmission 0f2 o ' 0#2 0 ' Doo,L"ads VM" 0 ' u/p u ' Floor Transmission 70ft' V ' 70u" 98 ' Partitions 0ft2 V ' 00" 0 - camn0 Ofp O ' Ofp U ' Overhead Lighting oovv 129 ' o 0 ' Task Lighting Ovv O ' 0 o ' Electric Equipment Ovv O - V U - People 1 230 120 V U V Infiltration ' V 0 ' V 0 Mivpynanoovn ' o o ' O o Safety Factor 0%/0% o o O% O o ^> Total Zone Loads ' u000 120 ' 781 o Zone Conditioning ' 1914 128 - 766 U Plenum Wall Load O% O - 0 V ' Plenum Roof Load o% n - n u ' Plenum Lighting Load o% O ' o U - Return Fan Load 110CFm O ' 110Crm o ' Ventilation Load 30Crm 161 '120 oOCFM 15*0 U Supply Fan Load 110CFM O ' 110CrM D ' Space Fan Coil Fans ' U - ' V ' Duct Heat Gain /Loss 0% 0 ' O% O ' >* Total System Loads ' oozs o ' cuos o Central Cooling Coil ' 2070 O ' O o Central Heating Coil o _ ' 0000 ' ~pTotal Conditioning - 2076 0 ' 2306 $ Key: Positive values are 69loads Negative values are »»y /pvus Positive values are htgloads Negative values are ug muus Hourly Analysis Program 5.11 Page am33 Air System Design Load Summary for ZONE 09~BUNK R109 IDU~1.7 Project Name: am7.092 FS 52Tuxwila Prepared by: The Greenbusch Group, Inc. 08/02/2019 DESIGN COOLING DESIGN HEATING COOLING DATA *JSep 1400 oOOuwGOAoo/wa ou.s^p/ox.o~p HEATING DATA ATDES *TG *sxnwooAoo/vva 23.0~p/1e2^p ZONE LOADS Details Sensible <BTu/h4 Latent (BTV/hr) Details Sensible (BTV/h4 Latent (BTU/hr) Window & Skylight Solar Loads 27ft,1 1410 - 27#" - - Wall Transmission 105fp 207 105f2 108 Roof Transmission oOAp 107 oD#" 116 ' Window Transmission crMP 33 ' 27n2 513 ' Skylight Transmission 0ft2 O o#" O ' 000l-oadu nM" D' OMP o ' Floor Transmission 7082 0 ' 7002 100 - Partitions 0ft2 O ' oW O - Ceiling 0ft2 U - ¢(f V ' Overhead Lighting 34vv 129 ' V V - Task Lighting Ovv O - o o Electric Equipment ovv O o O ' People 1 230 120 o U o mokm\ion o 0 o U Min0000neova ' o 0 o U Safety Factor 0%/0% U V V% U V —rma|ZvneLoaam ' 2115 120 ' 897 V Zone Conditioning ' 2072 120 ' 848 o Plenum Wall Load u% 0 V o ' Plenum Roof Load om o o o Plenum Lighting Load 0% O ' o n Return Fan Load 114Cpm o 1/*CFm O Ventilation Load ooCrm 174 '120 ooCrm 1533 o Supply Fan Load 114CFm U 114CFm o Space Fan Coil Fans ' O - ' V - Duct Heat Gain /Loss V% 0 ' 0% O ' >> Total System Loads - 2248 o - 2380 0 Central Cooling Coil - 2246 o ' o o Central Heating Coil ' o uouo ' >> Total Conditioning ' uuwV o ' cxoo o mvp Positive values are ueloads Negative values are htgloads Positive values are h»yloads Negative values are c|eloads Hourly Analysis Program 5.11 Page oof 33 Air System Design Load Summary for ZONE I O-BUNK R1 08 IDU-1J0 Project wamp:oV17.092 F852Tukwila Prepared by: The GmenbvschGroup, Inc. VV/0zD01V DESIGN COOLING DESIGN HEATING COOLING DATA ATSep 1xoo 000uwmoxoB/vvo 81.0^p/63.3^p HEATING DATA xTDES *Ta xsxnwooAoa/vva 23.0^p/19.2^p ZONE LOADS Details Sensible (BTU/hr) Latent <BTu/h4 Details Sensible (BTu/hr) Latent (BTU/hr) windmw& Skylight Solar Loads 27fp 1428 - 27fp ' ' Wall Transmission 105n" 251 ' 105f12 215 ' Roof Transmission Onp O' Ofp O ' Window Transmission 27*" cO 27M" 513 ' Skylight Transmission 0M12 o ' 082 0 ' Doo,l-oadn Oh^ O ' Vfp O ' Floor Transmission 7082 u - 708" 100 - Partitions 0012 O ' Uft, V ' Ceiling 002 O ' 082 D ' Overhead Lighting anvv 129 - U V - Task Lighting ow o o o Electric Equipment ow o - 0 u People G 1880 1620 0 o O Infiltration ' o o ' 0 o miamUanoovo ' O O ' U O Safety Factor 0%/0% O o U% U O >> Total Zone Loads - 3508 1620 - 828 0 Zone Conditioning ' 3483 1620 - 864 V Plenum Wall Load V% V ' O V - Plenum Roof Load om o o o ' Plenum Lighting Load o% o o o Return Fan Load 188Crm O 188Crm O ' Ventilation Load oonFw 128 '518 oocFm 155e n Supply Fan Load 188CrM o ' 188CpM n ' Space Fan Coil Fans ' V ' ' V - Duct Heat Gain /Loss 0% O ' V% 0 ' >> Total System Loads ' 3609 1102 ' 2423 O Central Cooling Coil ' onoo 1102 o o Central Heating Coil ' n ' 2423 ' *> Total Conditioning ' neoe 1102 ' o*oa o Key: Positive values are ueloads Negative values are h»yloads Positive values are moloads Negative values are c|eloads Hourly Analysis Program 5.11 Page 10 of 33 Air System Design Load Summary for ZONE 11-GEAR/LAUND RHRV, EUH-7,8 Project Name: 2017.092 FS 52 Tukwila 08/02/2019 Prepared by: The Greenbusch Group, Inc, 09:43AM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 511 ft2 567 - 511 ft2 589 Roof Transmission 0 ft2 0 - 0 ft2 0 Window Transmission 0 ft2 0 - 0 ft2 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 21 ft2 44 - 21 ft2 272 - Floor Transmission 1194 ft2 0 - 1194 ft2 197 Partitions 0 ft 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 645 W 2200 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 7 3380 5670 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6191 5670 - 1058 0 Zone Conditioning - 6057 5670 - 682 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1546 CFM 0 - 1546 CFM 0 - Ventilation Load 1500 CFM 13942 -5670 1500 CFM 55600 0 Supply Fan Load 1546 CFM 0 - 1546 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 19999 0 - 56281 0 Central Cooling Coil - 19999 0 - 0 0 Central Heating Coil - 0 - - 56281 - >> Total Conditioning - 19999 0 - 56281 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 11 of 33 Air System Design Load Summary for ZONE 12~CORRIDOR IDU~1.1 0 Project Name: 2O17.092FS52Tukwila Prepared by: The GreenbvscmGroup, Inc. O802/uO1� DESIGN COOLING DESIGN HEATING COOLING DATA ATJul 1ono 000umaoAoo/vvo 85.0~p/65.0^F HEATING DATA ATDES *To *sxT|wooAoo/wo 23.0^r/19.2^p ZONE LOADS Details Sensible (oTu/xr) Latent (oTumr) Details Sensible (oTu/xr) Latent (BTu/hr) VVindmw& Skylight Solar Loads 0fp O - VW - - Wall Transmission OfP 0' Dfp O ' Roof Transmission 0f2 o ' OnP 0 ' Window Transmission O#` O O*" O ' Skylight Transmission OfP o ' O,P o ovu l-vpdv O*" O ' V*" O ' Floor Transmission 140ft2 o ' 140M2 O ' Partitions Oo" 0 ' VV= 0 ' Ceiling Ofp O ' 082 O ' Overhead Lighting oow 304 ' o O ' Task Lighting Ovv o ' o o Electric Equipment Uvv u - U D ' People V 0 U 0 0 V Infiltration ' o V ' n o mixuonanomuo ' o 0 ' O o Safety Factor 0%/0% o 0 n% O o >> Total Zone Loads ' »o* o ' o o Zone Conditioning ' 274 n ' V U Plenum Wall Load O% O ' 0 O ' Plenum Roof Load om o ' V o - Plenum Lighting Load o% O - o o ' Return Fan Load VOCFw n ' OOCpm o Ventilation Load ooCFm oos 0 ooCFM 3124 o Supply Fan Load VnCFM O - 60CFw 8 - Space Fan Coil Fans ' V ' ' O ' Duct Heat Gain / Loss 0% o ' Om n —Tmo|nvstemLuuus ' ouo o ' 3124 o Central Cooling Coil ' ouo O ' 0 o Central Heating Coil ' O ' 3124 ' >> Total Conditioning - 829 o - 3124 u Key: Positive values are cIg|oads Negative values are xtgloads Positive values are h,gloads Negative values are moloads Hourly Analysis Program 5.11 Page 12 of 33 Air System Design Load Summary for ZONE 13-ENTRY 1DU-1 .11 Prepared by: The Greenbusch Group, Inc. O8m2/2D1� DESIGN COOLING DESIGN HEATING �cooumoOAoo/vva COOLING DATA xTJun 14mo uos^p/Vw.u^r HEATING DATA ATDES xTa *sAT|mmoAoa/vvo 23.0^p/19.2~p ZVNELOADS Details Sensible (BTU/hr) Latent (BTu/hr) Details Sensible (BTU/h4 Latent (BTV/hr) VVindmw& Skylight Solar Loads 129it' 5324 - 128ft2 - - Wall Transmission 612f2 nuo ' 012,p ouo ' Roof Transmission 0M2 0' 0ft2 O ' Window Transmission 129f2 184 ' 129ft2 000n ' Skylight Transmission OfP U 0ft2 o ' 000 l-oauv 21#2 32 21fp 381 ' Floor Transmission 700f2 U ' rmV*" 819 ' Partitions 0W O ' O*` O ' Ceiling 0ft2 0 ' O*` 0 ' Overhead Lighting 382YY 1304 ' V O ' Task Lighting ow o ' 0 o ' Electric Equipment OVV o ' O o ' People 1 uoo 120 o 0 O Infiltration o O o O Miaoononouuo ' O O ' 0 O Safety Factor 0%/0% O U O% V O >> Total Zone Loads - 7771 120 ' 4489 0 Zone Conditioning ' 7736 120 - 4516 V Plenum Wall Load o% o u o Plenum Roof Load om o o o ' Plenum Lighting Load O% O ' o o ' Romm Fan Load 478CFM o ' 478CFM o ' Ventilation Load 200Crm 1363 '120 uVUCpM 1024e o Supply Fan Load *78crm o 478CFw o Space Fan Coil Fans ' 8 ' ' U ' Duct Heat Gain /Loss O% O ' U% V ' >> Total System Loads - uuVV O - 14765 O Central Cooling Coil ' nOoo O - n o Central Heating Coil ' o ' 14765 ' »^ Total Conditioning ' youu o ' 1*/65 o nop Positive values are cigloads Negative values are n*oloads Positive values are h»gloads Negative values are o/eloads Hourly Analysis Program 5.11 Page 13 of 33 ^ Air System Design Load Summary for ZONE 14-PHYS TRAIN IDU~1.12 Project Name: 201rO92p852Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/2019 DESIGN COOLING DESIGN HEATING COOLING DATA ATJul 1mm 000umooAos/wB os.o^p/as.o^p HEATING DATA ATDES nTo *sAT|wGOAoa/vva 23.0^F/19.2^p ZONE LOADS Details Sensible (BTV/h4 Latent (BTV/hr) Details Sensible <BTV(h4 Latent (BTU/br) Window & Skylight Solar Loads 48ft2 roO ' 48np ' ' Wall Transmission 474f2 318 ' 474*2 764 ' Roof Transmission ofp o' 0#2 0 ' Window Transmission 48ft2 85 ' 48ft2 728 ' Skylight Transmission Vfp O ' V*" O ' 000,Lvaun ofP O ' 0#" 0 ' Floor Transmission 798fp O ' 79982 736 ' Partitions ofP o ' 0fi:2 o ' Ceiling 0ft2 0 ' 0ft2 V - Overhead Lighting *31 vv 1472 - O V - Task Lighting ovv o O o ' Electric Equipment Ow o ' O o ' People 1 uno 120 o 0 o |mhhradun - U V - V V Miscellaneous ' V o - V V Safety Factor 0%/0G O O o% 0 o ^^ Total Zone Loads ' oonx 120 ' uoue o Zone Conditioning 2916 120 ' 2001 u Plenum Wall Load U% o - V n ' Plenum Roof Load V% o - V V - Plenum Lighting Load O% o O n ' Romm pan Load 400CFm 0 400CpM o ' Ventilation Load 400CFm 3656 '120 400CpM u000s o Supply Fan Load 400CFM V ' *UUCFm O ' Space Fan Coil Fans ' V - - V - Duct Heat Gain /Loss o% o ' o% o ^~ Total System Loads ' osm o ' uzsos o Central Cooling Coil ' 6573 o o o Central Heating Coil - 0 - ' 22626 - >> Total Conditioning ' 6573 V - 22626 0 Key: Positive values are o|e loads Negative values are h»o |nuus Positive values are xte |vmus Negative values are me loads Hourly Analysis Program 5.11 Page 14m33 Air System Design Load Summary for ZONE 15-DECON EUH-1 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/201c. 09:43Alv DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 -- 0 ft2 - Wall Transmission 424 ft2 421 - 424 ft2 515 - Roof Transmission 175 ft2 292 - 175 ft2 170 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 21 ft2 44 - 21 ft2 287 - Floor Transmission 175 ft2 0 - 175 ft2 206 Partitions 0 ft 0 - 0 ft' 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 94 W 322 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 1080 0 - 1179 0 Zone Conditioning - 1010 0 - 1180 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 300 CFM 0 - 300 CFM 0 - Ventilation Load 300 CFM 2783 0 300 CFM 11798 Supply Fan Load 300 CFM 0 - 300 CFM 0 Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - > Total System Loads • 3793 0 - 12977 0 Central Cooling Coil - 3793 0 - 0 0 Central- Heating Coil 0 - - 12977 - » Total Conditioning - 3793 0 - 12977 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 15 of 33 Air System Design Load Summary for ZONE 16-EMS DRY EUH-2 Prepared by: The Greenbusch Group, Inc. 08/02/2019 DESIGN COOLING DESIGN HEATING COOLING DATA xTAug 1mm cooumoo400/wEI us.o^p/au.o^p HEATING DATA ATDES *To *sAT|wGOAog/vvo 23.0^p/19.2^p ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTV/hr) Latent (BTu/hr) Window & Skylight Solar Loads VA. 0' Vft, - - Wall Transmission 118h2 50 ' 118rF 144 ' Roof Transmission 98 ft2 144 98 ft2 95 ' Window Transmission 0r2 o ' O*` O - Skylight Transmission 08" O ' 0ft2 O ' Doo,Loads 002 0 0f2 O ' Floor Transmission 98h" 0 - 98ft2 09 - Partitions VM" V ' Ofp O ' Ceiling O(p V ' Ofp O ' Overhead Lighting 53vv 180 - 0 O - Task Lighting ow o ' o n ' Electric Equipment OvV o ' O o ' People O o o o 0 o Infiltration ' 0 0 ' o O Miscellaneous ' o o ' o o Safety Factor 0%/0% V 0 0% U O ~> Total Zone Loads - 380 V ' 328 o Zone Conditioning - 358 O ' 294 O Plenum Wall Load O% V ' n o Plenum Roof Load nm o o o Plenum Lighting Load o% n ' o n ' Return Fan Load unoCrM 0 ' aooCrw o ' Ventilation Load 250crM 2302 O uooCrM 9795 o Supply Fan Load 250CpM o ' uuoCpM o ' Space Fan Coil Fans ' V ' ' U ' Duct Heat Gain /Loss V% V ' O% V - >> Total System Loads - 2661 V - /0089 V Central Cooling Coil 2661 n ' O O Central Heating Coil ' o ' 10089 ' p^Total Conditioning ' 2661 o ' 10089 o Key: Positive values are ugloads Negative values are xtgloads Positive values are »Vnloads Negative values are ugloads Hourly Analysis Program 5.11 Page 1nm33 Air System Design Load Summary for ZONE 17-EMS EUH-3,4 Project Name: oO17.09mFS5oTukwila Prepared by: The Greenbusch Group, Inc. Oo/0c/2O1� DESIGN COOLING DESIGN HEATING COOLING DATA *Jxu|1omo oOoumooAoo/vvs oo.o^p/oso^p HEATING DATA ATDES *TG xsxnwooAoa/wo 23.0~p/1e.2~p ZONE LOADS Details Sensible <BTV/h0 |movm (BTU/h4 Details Sensible (BTUmr) Latent (BTU/h4 Window & Skylight Solar Loads ofp U' 0ft2 ' ' Wall Transmission 483fp 255 ' 483f2 429 Roof Transmission *13*2 090 ' 413nP 293 Window Transmission 0ft2 0 - Uk" O ' Skylight Transmission 0ft2 V - Vfr O - Doo,Lvaus 0f2 o ' OfP O ' Floor Transmission 413f2 O ' 413np 272 Partitions 0f2 V Ofp D ' Ceiling 0ft2 O ' 8*" O ' Overhead Lighting canw /nn ' o 0 ' Task Lighting 0Vv o ' o 0 ' Electric Equipment ow o O O ' People o 0 0 D 0 0 Infiltration ' U n ' O o Miscellaneous ' V O ' O V Safety Factor 0%/0% n U o% o o >> Total Zone Loads ' 1704 o ' oo* o Zone Conditioning ' 1685 0 ' ouo o Plenum Wall Load 0% 0 - V 0 ' Plenum Roof Load nm n ' n n ' p|onvm Lighting Load o% O O o nemm Fan Load 650opm o ' OnoCFM o Ventilation Load VoUCpM 00e6 0 OnoCFw 18515 o Supply Fan Load 650CFM V ' 850CFm U ' Space Fan Coil Fans - O ' ' O - Duct Heat Gain /Loss O% o o% o p>Total System Loads ' 7782 o ' 19**5 o Central Cooling Coil ' 7782 o o O Central Heating Coil ' V ' ' 19445 ~> Total Conditioning - 77$2 O 19*45 0 Key: Positive values are meloads Negative values are mg loads Positive values are meloads Negative values are me muus Hourly Analysis Program 5.11 Page 1rm33 Air System Design Load Summary for ZONE 18~SCBA EUH-' Project Name: mo17.092FSnuTukwila Prepared by: The Greenbusch Group, Inc. O8/0o/2O1V DESIGN COOLING DESIGN HEATING COOLING DATA xTJu|1aoo coouwmoAoo/vvB ux.o^p/en.o~r HEATING DATA ATDES *Tm xsAT|woowoB/wo 23.0^p/1l9.2~p ZONE LOADS Details Sensible (oTumr) Latent (a7umr) oomi|s Sensible (oTu/hr) Latent (BTU/or) Window &Skylight Solar Loads Uk" O - 00p - ' Wall Transmission 127*" 67 ' 127fp 205 ' Roof Transmission 108fp 181 ' 108f2 140 ' Window Transmission ofp 0' 0*" o ' Skylight Transmission OfP 0 ofP 0 ' ovu,Loaus 0f2 u - 0f2 V Floor Transmission 108ft2 n ' 108*2 180 ' Partitions VV, V ' OfP V - Ceiling ofp 0 ' 00" O ' Overhead Lighting oow con ' o o ' Task Lighting ow 0 o o ' Electric Equipment uvv V ' u V ' People O O 0 O V O Infiltration ' V n - V V Miscellaneous 0 o o O Safety Factor 0%/06 O 0 O% O O *> Total Zone Loads ' *48 n ' 475 o Zone Conditioning ' 412 V ' 459 O Plenum Wall Load V% 0 ' V n - Plenum Roof Load n% o u o ' Plenum Lighting Load o% o ' o o ' Return Fan Load 34orm n 34oFM o ' Ventilation Load 13CFM 113 o 13CFm 000 o Supply Fan Load 34CFM V - 34CFm U - Space Fan Coll Fans - O ' ' V ' Duct Heat Gain /Loss O% O ' 0% 0 ' >pTotal System Loads ' nun o ' 1118 o Central Cooling Coil ' ouo 0 ' o o Central Heating Coil ' o ' ' 1118 ' >* Total Conditioning - 525 V ' 1118 0 Key; Positive values are c|oloads Negative values are »teloads Positive values are htgloads Negative values are c|oloads Hourly Analysis Program 5.11 Page 18 of 33 Air System Design Load Summary for ZONE 19- APP BAY UH-1,2,3,4 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/201 c. 09:43AIv DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 596 ft2 28278 - 596 ft2 - - Wall Transmission 2627 ft2 2308 - 2627 ft2 4234 - Roof Transmission 3943 ft2 6594 - 3943 ft2 5084 - Window Transmission 452 ft2 647 - 452 ft2 5537 Skylight Transmission 144 ft2 412 - 144 ft2 3528 - Door Loads 1176 ft2 2826 1176 ft2 24202 - Floor Transmission 4087 ft2 0 - 4087 ft2 4665 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1839 W 6275 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 4 1180 1820 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 48520 1820 - 47250 0 Zone Conditioning - 45567 1820 - 45749 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 4500 CFM 0 - 4500 CFM 0 - Ventilation Load 4500 CFM 39536 -1820 4500 CFM 229356 0 Supply Fan Load 4500 CFM 0 - 4500 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 85104 0 - 275105 0 Central Cooling Coil - 85104 0 - 0 0 Central Heating Coil - 0 - - 275105 - » Total Conditioning - 85104 0 - 275105 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 19 of 33 Air System Design Load Summary for ZONE 20 - GREAT RM IDU-2.3 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/2019 09:43AN) DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 125 ft2 3246 - 125 ft2 - - Wall Transmission 984 ft2 1587 - 984 ft2 2384 - Roof Transmission 886 ft2 1482 - 886 ft2 1143 - Window Transmission 125 ft2 252 - 125 ft2 2159 - Skylight Transmission 0 ft2 0 - 0 ft2 0 .• Door Loads 21 ft2 44 - 21 ft2 381 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 _ Ceiling 0 ft2 0 - 0 ft2 0 _ Overhead Lighting 479 W 1633 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 8 1960 1640 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 10205 1640 - 6067 0 Zone Conditioning - 9855 1640 - 5858 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 534 CFM 0 - 534 CFM 0 - Ventilation Load 115 CFM 953 -1174 115 CFM 5841 0 Supply Fan Load 534 CFM 0 - 534 CFM 0 _ Space Fan Coil Fans - 0 - - 0 . Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 10808 466 - 11700 0 Central Cooling Coil - 10808 466 - 0 0 Central Heating Coil - 0 - - 11700 - >> Total Conditioning - 10808 466 - 11700 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 20 of 33 ` Air System Design Load Summary for ZONE 21 - STATION OFFICE IDU-2.2 Prepared by. The Gmanbvuo Group, Inc. 09:43Am DESIGN COOLING DESIGN HEATING COOLING DATA AT Jw|1500 C0OUNGOADB/VVE! 85.0`F(65.0q= HEATING DATA ATDES HTG VEA0NGOADB/WB 23.O"F(19.2nF ZONE LOADS Details Sensible (eTumr) Latent (oTumr) omoi|, ovnsiu|o (eTu/x0 Latent (oTu/»r) Window GSkylight Solar Loads 0ft2 O ' 0ft2 ' ' Wall Transmission 120fp 273 ' 120f2 281 ' Roof Transmission 513,2 858 513o2 861 - Window Transmission 0ft2 0 - Vfp V ' Skylight Transmission 81f O - 0*" 0 - 000,l-oado On" 0' o#P 0 Floor Transmission ofP o ' OoP 0 ' Partitions Onp 0 o#P n ' Ceiling OnP o ' oM^ 0 Overhead Lighting 277vv y*o ' o u - Task Lighting OYV O ' 0 o ' Electric Equipment OYv O ' o U ' People 8 1860 m^o o 0 O Infiltration ' 0 O ' o O miauonanaoun ' O O ' n 0 Safety Factor n%/n& 0 O n% o O >> Total Zone Loads - 4036 1644 - e52 u Zone Conditioning ' 3865 1640 ' 883 O Plenum Wall Load o% V - U V - Plenum Roof Load om n ' o o Plenum Lighting Load o% o ' o o nemm Fan Load 212CFm o - 212oFw o Ventilation Load 100Cpm 816 1510 100CFm 5154 o Supply Fan Load 212Cpw o - 212CFm u - Space Fan Coil Fans - o - ' V - Duct Heat Gain /Loss O% O - O% V ' p^Total System Loads ' *681 130 ' soxr o Central Cooling Coil ' 4681 131 o o Central Heating Coil ' O ' 6037 ' ^^ Total Conditioning ' 468 131 ' soxr o Key: Positive values are 'Ig loads Negative values are htg loads positive values are msloads Negative values are c|g|wads Hourly Analysis Program 5.11 Page 21 of 33 Air System Design Load Summary for ZONE 22 - CAPT OFFICE IDU-2.1 Project Name: 2017.092 FS 52 Tukwila 08/02/2019 Prepared by: The Greenbusch Group, Inc. 09:43AIV DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 82.2 °F / 64.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 54 ft2 1796 54 ft2 - - Wall Transmission 334 ft2 585 334 ft2 809 - Roof Transmission 161 ft2 207 161 ft2 207 - Window T ans ission 54ft2 8 54ft2 1044 - Skylight Transmission 0 ft2 0 0 ft2 0 ... Door Loads 0 ft2 0 0 ft2 0 - Floor Transmission 0 ft2 0 0 ft2 0 - Partitions 0 ft2 0 0 ft2 0 - Ceiling 0 ft2 0 0 ft2 0 - Overhead Lighting 87 W 296 0 0 - Task Lighting 0 W 0 0 0 - Electric Equipment 0 W 0 0 0 - People 8 1960 1640 0 0 Infiltration - 0 0 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4926 1640 - 2060 Zone Conditioning - 4750 1640 2028 Plenum Wall Load 0% 0 0 - Plenum Roof Load 0% 0 0 0 - Plenum Lighting Load 0% 0 0 0 - Return Fan Load 258 CFM 0 258 CFM 0 - Ventilation Load 50 CFM 247 -675 50 CFM 2564 0 Supply Fan Load 258 CFM 0 - 258 CFM 0 - Space Fan Coil Fans - 0 - 0 - Duct Heat Gain / Loss 0% 0 0% 0 - >> Total System Loads - 4997 965 - 4592 Central Cooling Coil - 4997 965 0 Central Heating Coil - 0 - 4592 - >> Total Conditioning - 4997 965 - 4592 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 22 of 33 Air System Design Load Summary for ZONE 23 - LUNCH IDU-2.13 Project Name: 2017.092 FS 52 Tukwila Prepared byffhe Greenbusch Group, Inc, 08/02/2019 09:43AN DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WB 82.5 °F / 63.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window 8 Skylight Solar Loads 64 ft' 1840 - 64 ft2 - - Wall Transmission 160 ft' 474 - 160 ft2 388 - Roof Transmission 455 ft' 539 - 455 ft2 586 - Window Transmission 64 ft 62 - 64 ft' 972 . Skylight Transmission 0 ft2 0 - 0 ft' 0 . Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 0 ft' 0 - 0 ft2 0 - Partitions 0 ft' 0 - 0 ft2 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 245 W 838 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 8 1960 1640 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 5712 1640 - 1946 0 Zone Conditioning - 5579 1640 - 1843 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 299 CFM 0 - 299 CFM 0 - Ventilation Load 100 CFM 562 -1329 100 CFM 5135 0 Supply Fan Load 299 CFM 0 - 299 CFM . Space Fan Coil Fans - 0 - - 0 . Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 6141 311 - 6978 0 Central Cooling Coil - 6141 311 - 0 0 Central Heating Coil - 0 - - 6978 - » Total Conditioning - 6141 311 - 6978 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 23 of 33 ^ Air System Design Load Summary for ZONE 24-BC R205 IDU-2.7 Project Name: 2017.092FS52 Tukwila Prepared by: The GpenbuocmGroup, Inc. DESIGN COOLING DESIGN HEATING COOLING DATA ATSep 14uu COOVNGOADB/VVB 82.5"r/63.8^F HEATING DATA ATDES *TG VEKUNGOADB/VVB 28.O,F/19,2~r ZowsLoAon Details Sensible (eTu/hr) Laoo,u (aTumr) Details Sensible (eTumr) Latent (o7umr) Window & Skylight Solar Loads 2782 1352 ' 27ft2 ' ' Wall Transmission 11082 325 - 110ft, 265 ' Roof Transmission 139ft2 16* - 139fP 180 - Window Transmission 278P 32 ' 2782 503 ' Skylight Transmission Onp o 002 0 Doo,l-uads o#p 0' OnP V ' Floor Transmission V*" O - Vft, 0 ' Partitions Oh" 0 ofp O Ceiling ofP 0 ' Ofp O ' Overhead Lighting rsvv 257 ' O o - Task Lighting 0YY U ' O O ' Electric Equipment ovv 0 ' 0 O ' People o 1960 16*0 O o o mfixmuon ' 0 O ' O O Miscellaneous ' V 0 ' 8 O Safety Factor 0%/0% V n V% o n ^^ Total Zone Loads ' 4091 1640 ' o*o o Zone Conditioning uoou 16*0 ooe o Plenum Wall Load O% o - V 8 ' Plenum Roof Load n% o - V V - Plenum Lighting Load U% o ' o n Return Fan Load 216CFM O ' 216CFm 0 ' Ventilation Load auCFm uoo '843 uuCrm zsru o Supply Fan Load 216CFM V ' 216 CFM V ' Space Fan Coil Fans o ' o Duct Heat Gain /Loss o% 0 ' om o ' >> Total System Loads ' *244 ror ' o*oa o Central Cooling Coil - 4244 797 - V 0 Central Heating Coil ' V - - 3462 - >> Total Conditioning ' *2*4 rer ' a^so o Key: Positive values are meloads Negative values are »»oloads Positive values are xteloads Negative values are meloads Hourly Analysis Program 5.11 Page 24m33 Air System Design Load Sumrnary for ZONE 25 - A. CHIEF R204 IDU-2.8 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/201 09:43Alv DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WB 82.5 °F / 63.8 °F HEATING DATA AT DES HTG HEATING OA DB I WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 27 ft2 1352 - 27 ft2 - - Wall Transmission 110 ft2 325 - 110 ft2 265 - Roof Transmission 139 ft2 165 - 139 ft' 180 - Window Transmission 27 ft2 32 - 27 ft2 503 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 Overhead Lighting 75 W 257 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 8 1960 1640 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4091 1640 • 948 0 Zone Conditioning - 3982 1640 - 892 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 216 CFM 0 - 216 CFM 0 - Ventilation Load 50 CFM 262 -843 50 CFM 2570 0 Supply Fan Load 216 CFM 0 - 216 CFM 0 - Space Fan Coil Fans - 0 - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 4244 797 - 3462 0 Central Cooling Coil - 4244 797 - 0 0 Central Heating Coil - 0 - - 3462 - » Total Conditioning - 4244 797 - 3462 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 25 of 33 Air System Design Load Summary for ZONE 26 - A. CHIEF R203 IDU-2.9 Project Name: 2017.092 FS 52 Tukwila 08/02/2019 Prepared by: The Greenbusch Group, Inc. 09:43AN DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WEI 82.5 °F / 63.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 27 ft2 1352 - 27 ft2 - - Wall Transmission 110 ft2 325 - 110 ft2 265 - Roof Transmission 139 ft2 165 - 139 ft2 180 - Window Transmission 27 ft2 32 - 27 ft2 503 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 • 0 ft2 0 • Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 75 W 257 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 8 1960 1640 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 ..0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4091 1640 - 948 0 Zone Conditioning - 3982 1640 - 892 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 216 CFM 0 - 216 CFM 0 - Ventilation Load 50 CFM 262 -843 50 CFM 2570 0 Supply Fan Load 216 CFM 0 - 216 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 4244 797 - 3462 0 Central Cooling Coil - 4244 797 - 0 0 Central Heating Coil .. 0 - - 3462 - >> Total Conditioning - 4244 797 - 3462 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 26 of 33 ~ Air System Design Load Summary for ZONE 27~EOC/TRAINING IDU~2.6 Project Name: 2o1zO92FSs2Tukwila Prepared by: The Greenbusch Group, Inc. 08/0c/2O1V DESIGN COOLING DESIGN HEATING COOLING DATA xrJul 1son COOLING muoa/wo 84.5^r/64.8^p HEATING DATA x7DES *To yexT|waOAoo/vvo 23.0^p/19.2^p ZONE LOADS Details Sensible (oTu/nr) Latent (oTu/xr) Details uwnaimo (o7umr) Latent (aTu/hr) vvindmw& Skylight Solar Loads 00, O' Vh` ' ' Wall Transmission O*` O ' 0n` V ' Roof Transmission 917h2 1381 ' 917fp 1182 ' Window Transmission OnP o 0f,2 U ' Skylight Transmission oh" O ' OM` O Doo,Loads 0ft2 u ' ooP V ' Floor Transmission 002 V ' 0ft2 V ' Partitions Oft, O ' 0ft2 g ' Ceiling OfP 0 ' O*" n ' Overhead Lighting 495vv 1689 ' n o ' Task Lighting Ovv o ' o o Electric Equipment Ovv u - u O - People 8 1960 1640 U V O Infiltration ' n o - V o Miscellaneous ' n 0 ' O o Safety Factor 0%/0% o O o% 0 o —Tvu,|ZvnnLvauu ' eono 1640 ' 1182 o Zone Conditioning ' 5018 1640 - 1264 V Plenum Wall Load O% V ' U O - Plenum Roof Load om o ' u n ' Plenum Lighting Load O% o o o ' Romm run Load 276CFm O ' oroCFM o Ventilation Load 150cFm 1157 '1640 150CFM 7751 o Supply Fan Load 270CFM 0 - 276CFM V - Space Fan Coil Fans ' O - ' O ' Duct Heat Gain /Loss O% O ' 0% o ^> Total System Loads ' 617* o ' 9015 n Central Cooling Coil ' 6174 o ' 0 n Central Heating Coil ' o ' 9015 ' ~> Total Conditioning - 6174 V - 9015 0 Key: Positive values are cIg4ads Negative values are htg loads Positive values are htgloads Negative values are cIg loads Hourly Analysis Program 5.11 Page 27 of 33 ° Air System Design Load Summary for ZONE 28 - ADMIN IDU-2.11 Project Name: x01zU92FS52Tukwila Prepared by: The GnmnbvschGroup, Inc. 08/02/2019 DESIGN COOLING DESIGN HEATING COOLING DATA ATJul 1400 COOLNGpADB(WEI 84.5"F/64.8"F HEATING DATA AT DESMTG � HEATING OA00/WB 23.0°P/1U^F � ZONE LOADS Details Sensible (oTomr) Latent (a7umr) ootaoa Sensible (o7u/nr) Latent (oTumr)� Window & Skylight Solar Loads 177h" 5922 ' 177#2 ' ' Wall Transmission 62802 1030 628fp 1521 Roof Transmission 523 f12 913 ' 523h2 074 - Window Transmission 177ft2 289 ' 177ft2 2759 - Skylight Transmission 0ft2 O - 0(t2 O - oou,l-oado 0f12 0 nh` O ' Floor Transmission 0r2 o' 0ft2 o ' Partitions oxP o 0ft2 O Ceiling ox^ 0 ' ofp O ' Overhead Lighting 282w mm - O O - Task Lighting VvY n - U o ' Electric Equipment OVY O - O V - People 8 1470 1230 o n 0 mmvonon ' U o ' o 0 Miscellaneous ' O V o o Safety Factor 0%/0% o O 0% o O ^= Total Zone Loads - 10588 1230 - 4e54 o Zone Conditioning ' 10282 1230 ' 4806 V Plenum Wall Load O% V ' O V ' Plenum Roof Load nm o n o ' Plenum Lighting Load U% o O o Return Fan Load 581 Crw o 581 CFM D Ventilation Load 150Crm 113e '1230 150CFm 7654 O Supply Fan Load 581 Cpm V - 581 CFw u ' Space Fan Coil Fans - V ' ' O ' Duct Heat Gain /Loss U% 0 ' 0m O - ^^ Total System Loads ' 11401 o ' 12*60 o Central Cooling Coil ' 11401 n ' O o Central Heating Coil ' o ' ' 12460 ' x~Total Conditioning ' 11401 o ' 12460 o Key: Positive values are ,Ig loads Negative values am°htg loads Positive values are muloads Negative values are cigloads Hourly Analysis Program 5.11 Page 28 of 33 Air System Design Load Summary for ZONE 29 - CHIEF IDU-2.10 Project Name: 2017.092 FS 52 Tukwila Prepared by: The Greenbusch Group, Inc. 08/02/2019 09:43Atv DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1300 COOLING OA DB / WB 83.0 °F / 64.3 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTUIhr) Latent (BTU/hr) Window & Skylight Solar Loads 47 ft 1461 - 47 ft2 - Wall Transmission 128 ft2 161 - 128 ft2 310 - Roof Transmission 189 ft2 326 - 189 ft2 244 - Window Transmission 47 ft2 70 - 47 ft2 872 - Skylight Transmission 0 ft2 0 - 0 ft2 0 ' Door Loads 0 ft2 0 , 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 . 0 ft2 - Overhead Lighting 102 W 348 - 0 0 - Task Lighting 0 W 0 - 0 0 _ Electric Equipment 0 W 0 - 0 0 - People 8 1960 1640 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 4326 1640 - 1426 0 Zone Conditioning - 4292 1640 - 1328 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 248 CFM 0 - 248 CFM 0 - Ventilation Load 50 CFM 310 -812 50 CFM 2567 0 Supply Fan Load 248 CFM 0 - 248 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - >> Total System Loads - 4602 828 - 3894 0 Central Cooling Coil - 4602 827 - 0 0 Central Heating Coil - 0 - - 3894 - >> Total Conditioning - 4602 827 - 3894 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 29 of 33 Air System Design Load Summary for ZONE 30 - CONFERENCE IDU-2.12 Project Name: c017.o92FS 52Tukwila 08/02/2010 Prepared by: The Gmonbvoo»Group, Inc. — 08:43AN osuIGm000uma DESIGN HEATING COOLING DATA AJJun 150W COOuNGOADB/vVg 84.0~P/65.0~F HEATING DATA AJDES HTG VEAT|NGDADB/VVB 23.0^F/1$.20F ZONE LOADS omai|o Sensible (aTu/»r) Latent (aTu/hr) Details s,nsiu|o (oTu/hr) Latent (BTu/xr) Window & Skylight Solar Loads xr#P ooa - 27ft2 ' ' Wall Transmission oxo*" 315 338fp 820 ' Roof Transmission 325k" 553 - 325fP 418 ' Window Transmission 27#2 4$ ' 37ft2 503 ' Skylight Transmission 0it2 O' n*" O - Ooo,Loedo 08" O ' 0ft2 0 Floor Transmission ou` o ' Ofp O ' Partitions Ofr O ' ofP o Ceiling Ofp O Ofr 0 ' Overhead Lighting 176vv oou - u o - Task Lighting 163vv 554 ' 0 0 ' Electric Equipment 163VY 554 - O O ' ponp|o 12 uo*D 2460 o o O mn|uavon o o ' O o Miscellaneous ' o o ' O O Safety Factor 0%/0% o o o% o O ~~ Total Zone Loads - aaao 2460 - 17*2 u Zone Conditioning - 6810 2460 ' 1717 u Plenum Wall Load O% 0 ' O o - Plenum Roof Load o% o o o Plenum Lighting Load o% 0 o o ' Return Fan Load 345CpM o ' 346CFm O ' Ventilation Load 100CFM 723 '1378 100oFm 5159 o Supply Fan umx 346CFw u - 346 CFm u - Space Fan Coil Fans ' V ' ' V ' Duct Heat Gain /Loss V% V - O% V ' >> Total System Loads - mux 1082 ' suro o Central Cooling Coil ' 7033 1082 o o Central Heating Coil ' 0 ' Voro ' *> Total Conditioning ' roax 1082 ' sor* o Key: Positive values are mgloads Negative values are x/gloads Positive values are nouloads Negative values are c|g|oads Hourly Analysis Program 5.11 Page 30m33 I Air System Design Load Summary for ZONE 31 - SHOP EUH-6 Project Name: on17.V9cFS5uTukwila Prepared by: The GeonbvoohGroup, Inc. nEaxam000umo DESIGN HEATING COOLING DATA ATJul 150m COnL|NGOADB/VYB 8e.0^F/65.0"F HEATING DATA ATDES MTG � HEAT|NGOADS/vVB 23.0"F/19.2°F � ZONE LOADS Details Sensible (BTumr) Latent UBTu/h, Details Sensible (BTu/hr) Latent (arumr) Window & Skylight Solar Loads 002 o' Unp ' ' Wall Transmission ^ocMP 326 452ft2 70 Roof Transmission 2168p 361 - 216ft2 uru Window Transmission 0f2 O - 0ft2 O ' Skylight Transmission Ofp V - 0(t2 O ' 000,l-oous OK" O n*` O Floor Transmission 210fP O ' 216M2 319 ' Partitions Ofp o ' OM" o ' Ceiling Ofp O 0ft2 O ' Overhead Lighting 117vv 398 ' o V - Task Lighting 0Vv O ' V V ' Electric Equipment OYY 0 - V O - People 0 O o O o o Infiltration ' O 0 - o o Miscellaneous ' O O - O o Safety Factor 0%/06 0 o 0% 0 o ^^ Total Zone Loads - 1085 u - 1325 u Zone Conditioning ' 1052 U ' 1233 V Plenum Wall Load O% V ' O 8 - Plenum Roof Load o% o o o ' p|anvm Lighting Load n% o o n Return Fan Load 150CFm o ' 150CFM o Ventilation Load 150CFm 1383 o 150CFM 7651 o Supply Fan Load 150CFm 0 ' 150CFm V - Space Fan Coil Fans ' D ' ' U - Duct Heat Gain /Loss 0% V - O% O ' >* Total System Loads ' o*^o o ' uuno o Central Cooling Coil ' 2445 o o 0 Central Heating Coil ' 0 ' ' 888* ' >* Total Conditioning ' o**u o ' oux* o m*v: Positive values are r/eloads Negative values are h4]loads Positive values are »,eloads Negative values are c|8|omds Hourly Analysis Program 5.11 Page 31 mn3 A Air System Design Load Summary for ZONE 32 - COMM R209 Project Name: uO17.092FS5uTukwila Prepared by: The Gmenuuoo»Group, Inc. Oo02/2V1p DESIGN COOLING DESIGN HEATING � COOLING DATA xTAug 150m cPOUNGOADB/\mB 85.0,P/65.0~F HEATING DATA ATDES HTG HEADNGOA0B/VVB 23.00F/19.2"F ZONE LOADS ootaxa Sensible (oTmxr) Latent (sTumr) Details Sensible (oTu/xr) Latent (BTumr) Window & Skylight Solar Loads 0012 o' 0,12 ' ' Wall Transmission ofp 0 ' OMP 0 ' Roof Transmission 118f12 171 ' 110nP 150 - Window Transmission UUP V - 0(12 u ' Skylight Transmission 0ft2 V ' 0f12 V ' 000,l-oudn OnP o ' 0f12 0 ' Floor Transmission OfP o ' O*^ 0 ' Partitions ofp O ' OfP o ' Ceiling 0f12 0 ' Ofp O ' Overhead Lighting oaw 198 - 0 0 - Task Lighting 58YY 1$8 ' U U ' Electric Equipment 116YY 396 ' U V ' People 0 o n V 0 o mhxmnon ' 0 O ' O 0 Miscellaneous ' 0 0 ' o O Safety Factor n%/n% O O n% o 0 ppTotal Zone Loads ' asu u - 150 u Zone Conditioning ' 333 O ' 126 V Plenum Wall Load 0% O ' V O - Plenum Roof Load o% o ' o o ' Plenum Lighting Load 0% 0 O o momm Fan Load 000CFm o ' 300CFm o ' Ventilation Load 0000Fm 2832 0 300CFm 15529 o Supply Fan Load 300CFw u - aouorm u - Space Fan Coil Fans ' O ' ' U ' Duct Heat Gain /Loss U% 0 - n% O - ^^ Total System Loads ' xrsn o ' 15656 o Central Cooling Coil ' nroo o ' O 0 Central Heating Coil ' o ' ' 15656 ' ^^ Total Conditioning ' orss o ' 15656 o Key: Positive values are c/uloads Negative values are xtgloads Positive values are xtoloads Negative values are c|g|oads Hourly Analysis Program 5,11 Page 32 of 33 ^ Air System Design Load Summary for ZONE 33~LVL2 SHELL IDU-2��,� Project Name: xo17�92�S52TvxwU � 08/02/2018 Prepared by: The Geonbux:»Group, Inc. 09:43A* DESIGN COOLING DESIGN HEATING COOLING DATA AJJul 14U0 COOL|NGoADB(VVB W4.5"F/84.8"F HEATING DATA ATDES MTG HEAnmGOADB/VVB 23.0"F/19.20F ZONE LOADS Details Sensible (eTu/xr) Latent (o7u/nr) ootaxu Sensible (BTumr) Latent (eTu8,r) Window & Skylight Solar Loads 332ft2 10702 332M" ' Wall Transmission 1423f2 uuco ' 14e3op 1899 ' Roof Transmission 3181fp 555* ' 3181,t2 2260 ' Window Transmission 332W 581 ' 332/t2 3110 ' Skylight Transmission 0ft2 O - DA, O ' Door Loads 0n2 0' OM" O ' Floor Transmission onp O ' o#" o ' Partitions 0*" O 0ft2 O ' Ceiling OxP o ' 0ft2 O ' Overhead Lighting 1718vv 5861 ' o u - Task Lighting 4w O ' o o - Electric Equipment nVY O ' D V - People o 1900 1640 o O O Infiltration O O ' o 0 Miscellaneous ' o O ' o O Safety Factor n%/o% O 0 o% o O -Tma|Znne Loads ' 26896 1640 ' 7269 u Zone Conditioning ' 25824 1640 ' 6523 V Plenum Wall Load V% V - U O - Plenum Roof Load om o o n ' Plenum Lighting Load o% O o o Return Fan Load 1416CFm o 1416CFm 0 Ventilation Load OCpM o o oCrm o o Supply Fan Load 1416Crw u ' 1416CFM o - Space Fan Coil Fans ' O ' ' O ' Duct Heat Gain /Loss n% O - o% O - —rmo|nrsuemLvadn ' uoouw 16*0 ' snex o Central Cooling Coil - 25824 1641 ' 0 o Central Heating Coil ' o ' oozm ' >* Total Conditioning ' 25824 1641 ' soux o Key: Positive values are cIgloads Negative values are htgloads Positive values are mgloads Negative values are dploads Hourly Analysis Program 5.11 Page 33m33 0 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director April 1, 2020 Andy Johnson Johansen Mechanical 20109 144th Ave NE Woodinville, WA 98072 RE: Request for Extension #1 Permit Number M19-0135 Dear Mr. johnson, This letter is in response to your written request for an extension to Permit M19-0135. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through October 7, 2020. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, ip Bill Rambo Permit Technician File: Permit No. M19-0135 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 0 ohansen Mechanical inc. 20109 144th Ave NE • Woodinville, WA 98072 (425) 481-2266 Bus • (425) 486-6933 Fax 3/10/2020 BILL RAMBO 6300 SOUTHCENTER BLVD SUITE #100 TUKWILLA, WA 98188 RE: Pennit No. M19-0135 FIRE STATION 52 15447 65 AVE S Dear Mr. Rambo, We have received your letter about our permit expiring on 4/7/2020 and wanted to request an extension on the building permit because work on the project has just started this month and will, not be completed until after the permit expires. Sincerely, Andy Johansen Request for Permit Exter.Aon # Current Expiration Date: Extension Request: Approved for _ I days L ! Denied (provide explanation) Signature; hlitials RECEIVED CITY OF TUKWILA MAR 1 0 2020 PERMIT CENTER 0 City of Tukwila Departtnent of Community Development 3/5/2020 IVY LEVANG1E 20109 144 AVE NE WOODINVILLE, WA 98072 RE: Permit No. M19-0135 FIRE STATION 52 15447 65 AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/7/2020. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/7/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M19-0135 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 22, 2019 William Hill, CBO, ACO BHC Consultants 1601 Fifth Ave, Ste 500 Seattle, WA 98101 RE: Supplemental Nonstructural Review Development Permit M19-0135 Tukwila Fire Station 52 —15447 65 .Ave S Dear Mr. Hill, Please review the enclosed set of plans and documents for nonstructural compliance with the 2015 International Mechanical Code. As always, once all items have been reviewed and deemed correct, please provide two approved sets of approved plans and calculations with original approval stamps back to the Permit Center, attention Building Official. If you should have any questions, please feel free contact us in the Permit Center at (206) 431-3670. Sincerely, Bill Rambo Permit Technician encl File: M19-0135 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0135 PROJECT NAME: FIRE STATION 52 SITE ADDRESS: 15447 65 AVE S X Original Plan Submittal Response to Correction Letter # DATE: 08/20/19 Revision # before Permit issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works PRELIMINARY REVIEW: A-1J\ PAN Fire Prevention Structural Planning Division Permit Coordinator s Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 08/22/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 09/19/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg LJ Fire 0 Ping 0 PW Ej Staff Initials: 12/18/2013 1 I ()ale Fs-Nilo! Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries A-Z th,dex Help - My thl Workplace Rights Trades & Licensing JOHANSEN MECHANICAL INC r529. Principals JOHANSEN, KEITH ALLEN, PRESIDENT HOLM, DEREK RICHARD, VICE PRESIDENT JOHANSEN, ALLEN D, PRESIDENT (End: 06/04/2015) JOHANSEN, ANITA J, SECRETARY (End: 06/04/2015) Doing business as JOHANSEN MECHANICAL INC WA UBI No. 600 495 164 20109 144th Ave NE WOODINVILLE, WA 98072 425-481-2266 KING County Business type Corporation Governing persons KEITH JOHANSEN ALLEN JOHANSEN, License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. JOHANMI173PK Effective -- expiration 10/12/1983— 02J02/2021 Bond DEVELOPERS SURETY & INDEM CO $12,000 00 Bond account no. 275167C Received by L&I Effective date 08/02/2010 07/31/2010 Expiration date Until Canceled Insurance Travelers Indemnity Company Th $1,000,000.00 Policy no. DTCO5K363952IND19 Received by L&I Effective date 01/15/2019 02/01/2019 Expiration date Help us improve 02/01/2020 Insurance history Savings.. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&l Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Registered training agent. Check their eligible programs and occupations. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. Account is current. L&I Account ID 482,787-00 Doing business as JOHANSEN MECHANICAL INC Estimated workers !reported Quarter 2 of Year 2019 "76 to 100 Workers" L&I account contact T5 / MARVIN GREEN (360)902-4967 - Email: GRMB235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training— Effective July 1, 2019 Exempt from this requirement. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/08/2018 Inspection no. 317949812 Location 2800 Beacon Avenue Seattle, WA 98144 Violations -© Washington State Dept of Labor & Industries. 'Jse of this site is subject to the laws of the state of Washington. Help us improve ABBREVIATIONS GRAPHIC SYMBOLS PROJECT DATA DIRECTORY DRAWING INDEX @ AT FP FIREPROOF PSI POUNDS PER SQUARE INCH PROJECT LOCATION OWNER GENERAL 0 DIAMETER OR ROUND FPHB FROST PROOF HOSE BIB PT POINT/POINT OF TANGENCY DETAIL INDICATOR 15447 65THAVE S City of Tukwila G001 COVER SHEET # POUND OR NUMBER FRM FRAMING PRESSURE TREATED FRP FIBERGLASS REINFORCED PTO FIELD PAINTED I XX ® DETAIL NUMBER TUKWILA, WA 98188 Public Works Department AB ANCHOR BOLT PANEL (NOT FACTORY FINISHED) SHEET NUMBER LEGAL O6200 Southcenter Blvd, Suite 100 LOT 17 OFF THE ABE AVERAGE BUILDING ELEVATION FRDT FIRE RETARDANT PTN PARTITION R HE INTERURBAN ADDITION TO SEATTLE, ACCORDING TO PLAT Tukwila, WA 98188 ARCHITECTURAL ABV ABOVE FRZR FREEZER RECORDED IN VOLUME 10 OF PLATS AT PAGE(S) 55, IN KING COUNTY, Rachel Bianchi (FOR REFERENCE ONLY FROM PHASE 2 CONSTRUCTION PERMIT SET) ACT ACOUSTIC TILE FS FULL SIZE QTR QUARTER WASHINGTON; EXCEPT THAT PORTION LYING NORTH OF A LINE DESCRIBED AS T.2064547566 ACW ALUMINUM -CLAD WOOD FSD FIRE SEPARATION DISTANCE QTY QUANTITY ELEVATION INDICATOR FOLLOWS: BEGINNINGATA POINT ON THE WEST LINE 210 FEET NORTH FROM A001 ARCHITECTURAL FULL SITE PLAN AD AREA DRAIN FT FOOT OR FEET XX e-- DETAIL NUMBER E: Rachel,Bianchi@TukwilaWA.gov ADJ ADJUSTABLE, ADJACENT PTO FOOTING R RISER/RADIUS/RESISTANCE .s-- SHEET NUMBER THESOUTHWESTCORNER;THENCENORTH LINE EAST630FEET,MOREOR A002 ENLARGED ARCHITECTURALSITEPLAN LESS, TO THE INTERSECTION OF THE WEST LINE OF 65THAVENUE SOUTH; AND AFF ABOVE FINISH FLOOR RB RUBBER BASE EXCEPT THAT PORTION THEREOF CONVEYED TO THE CITY OF TUKWILA BY OWNER'S REPRESENTATIVE A101 N FLOOR PLAN LEVEL 1 NORTH AHJ AUTHORITY HAVING GA GAUGE RD ROOF DRAIN DEED RECORDED UNDER RECORDING NO.7108120423; AND EXCEPT THAT Shiels Obletz Johnsen (SOJ) A101S FLOOR PLAN LEVEL 1 SOUTH JURISDICTION GAL GALLON REC RECEIVE PORTION LYING WITHIN M.W. ADDITION, ACCORDING TO THE PLAT RECORDED IN 800 51hAve, Suite 4130 A102N FLOOR PLAN LEVEL NORTH AHU AIR HANDLING UNIT GALV GALVANIZED REP REFERENCE ENLARGED ELEVATION INDICATOR VOLUME 53 OF PLATS AT PAGE 48, IN KING COUNTY, WASHINGTON; AND EXCEPT A102S FLOOR PLAN LEVEL SOUTH BASE Seattle, WA98104 ALT ALTERNATE GEN GENERAL REFR REFRIGERATOR � .4- DETAIL NUMBER THAT PORTION OF SAID LOT 17 DESCRIBED AS FOLLOWS: COMMENCING AT A102S.A FLOOR PLAN LEVEL 2 SOUTH ALTERNATE ALUMIAL ALUMINUM OR GROUND FAULT INTERRUPTER REINF REINFORCED q_- SHEET NUMBER POINT ON THE CENTERLINE OF RENTON-THREE TREE POINT ROAD NO. 2649AND Justine Kim & Julie DeDonato, A103N ROOF PLAN NORTH AP ACCESS PANEL GFRC GLASS FIBER REINFORCED READ REQUIRED THE WEST LINE OF SAID SECTION 23, TOWNSHIP 23 NORTH, RANGE 4 EAST, T: 206 40MO86 A1038 ROOF PLAN SOUTH APPD APPROVED CONCRETE RET RETURN W.M., IN KING COUNTY, WASHINGTON, SAID POINT BEING ENGINEER'S STATION E: jd@ancoraprojects.com APPROX APPROXIMATE GL GLASS REV REVERSE/REVISED/REVISION X 135+29.92 FROM WHICH THE SOUTHWEST CORNER OF SAID SECTION 23 BEARS ARCH ARCHITECTURAL ONO GROUND RF ROOF SOUTH VIT42" EAST, 2044.06 FEET; THENCE SOUTH 64°51'48" EAST 1647.24 ASF ABOVE SUBFLOOR GOVT GOVERNMENT RFG ROOFING INTERIOR ELEVATION INDICATOR ARCHITECT DETAIL NUMBER FEET; THENCE ON ACURVE TO THE RIGHT HAVING A RADIUS OF 955.37 FEET, 360 MECHANICAL AVG AVERAGE OR GRADE RH RIGHT HAND X XX �- FEET; THENCE SOUTH 63*1648" EAST 359.18 FEET; THENCE ON A CURVE TO THE WeinsteinA+U AXXX ® SHEET NUMBER 2200 Western Ave, Suite 301 GSM GALVANIZED SHEET METAL RIGID RIGID INSULATION LEFT HAVING A RADIUS OF 5729.65 FEET, 370 FEET; THENCE SOUTH 66°57'48" M001 ABBREVS„ LEGEND, NOTES &INDEX BAL BALANCING GWB GYPSUM WALL BOARD RL RAIN LEADER (INTERIOR) ELEVATION EAST 1162.53 FEET; THENCE ONACURVE TO THE LEFT HAVING RADIUS OF Seattle, WA 98121 M002 MECHANICAL SCHEDULES BD BOARD GYP GYPSUM RM ROOM 716.34 FEET, 442.40 FEET; THENCE NORTH 77°3842" EAST, 201.68 FEET; THENCE Emma Nowinski & Lauren Rock M003 MECHANICAL SCHEDULES BE BATH FAN EXHAUST FIND ROUND LEAVING SAID CENTERLINE OF SAID ROAD AND RUNNING NORTH 00°14'00" EAST, M004 MECHANICAL SCHEDULES BEL BELOW HB HOSE BIB R10 RANGEIOVEN //��XXXX�\ BUILDING SECTION INDICATOR 272.03 FEET; THENCE SOUTH 00°14'00" WEST, 87.94 FEET, MORE OR LESS, TO T. 206 443 8606 BEY BEYOND HC HANDICAP/HOLLOW CORE RO ROUGH OPENING ® DETAIL NUMBER E: emman@weinsteinau.com BLDG BUILDING HD HEADIHEAVY DUTY ROW RIGHT-OF-WAY1 X�1 ® SHEET NUMBER THE NORTHWESTERLY MARGIN OF VACATED MACADAM ROAD (ALSO KNOWN AS M101 MECHANICAL SITE PLAN- NOT INCLUDED JAMES CLARK ROAD NO. 2); THENCE SOUTH 49700" WESTALONG SAID BILK BLOCK, BLOCKING HDR HEADER RUB RUBBER NORTHWESTERLY MARGIN 106.38 FEET; THENCE NORTH 00°14'00" EAST, 312.55 CIVIL ENGINEER M201N MECHANICAL FOUNDATION PLAN NORTH BM BENCH MARK HDWD HARDWOOD RWL RAINWATER LEADER (INDOORS) FEET, MORE OR LESS, TO THE SOUTH LINE OF LOT 17 IN SAID INTERURBAN LPD Engineering M201S MECHANICAL FOUNDATION PLAN SOUTH BO BOTTOM OF HWVP HARDWOOD VENEER PLYWOOD ADDITION AND THE TRUE POINT OF BEGINNING; THENCE CONTINUING NORTH 1932 First Ave, Suite 201 BOT BOTTOM HDWR HARDWARE S SOUTH WALL SECTION INDICATOR 00°14'00" EAST, FEET; THENCE SOUTH 88°24'47" EAST PARALLEL WITH THE M301N FIRE PROTECTION DIAGRAM LEVEL 1 NORTH BRK MTL BRAKE METAL HE HOOD FAN EXHAUST SAW SALVAGED �j Seatge, WA 98101 () XX ® DETAIL NUMBER NORTHERLY LINE OF SAID LOT 17,170 FEET MORE ; T LESS, TO THE M302N FIRE PROTECTION DIAGRAM LEVEL 1 SOUTH 7SEPARATE -- BTWN BETWEEN HM HOLLOW METAL SAM SELF•AOHESIVE MEMBRANE ® SHEET NUMBER SOUTHWESTERLY MARGIN OF 65THAVENUE SOUTH; THENCE SOUTHEASTERLY Marc Setvizi M302N FIRE PROTECTION DIAGRAM LEVEL 2 NORTH ERMITHOL HOLLOW SBC IBC w/ SEATTLE AMENDMENTS ALONG SAID MARGIN TO THE SOUTHEAST CORNER OF SAID LOT 17; THENCE T: 206 725.1211 M302S FIRE PROTECTION DIAGRAM LEVEL 2 SOUTH FOR:C to C CENTER TO CENTER HOR/ sc SOLID CORE NORTH 89°09'00"WESTALONG THE SOUTH LINE OF LOT 17 TO THE TRUE POINT E: mares@ipdengineedng.com M302S.A FIRE PROTECTION DIAGRAM LEVEL 2 SOUTH ALT hipa!CAB CABINET HORIZ HORIZONTAL SCHED SCHEDULE OF BEGINNING. calCAP CAPACITY HP HIGH POINT SCW SOLID CORE WOOD M401N PLUMBING PLAN LEVEL 1 NORTHinCG CORNER GUARD HR HOUR SO SMOKE DETECTOR x13 EXTERIORITHERMAL LANDSCAPE ARCHITECT M401S PLUMBING PLAN LEVEL 1 SOUTH gCHT BABY CHANGING TABLE HRA HOT RUBBERIZED ASPHALT SECT SECTION ASSEMBLY INDICATOR KING COUNTY ZONING Swift Company, LLC M402N PLUMBING PLAN LEVEL 2 NORTH ping CIP CASTAN-PLACE HT HEIGHT SF SQUARE FEET I STOREFRONT OFFICE 3131 Western Ave, M423 M402S PLUMBING PLAN LEVEL 2 SOUTH City of Tukwila CJ CONTROL JOINT HWH HOT WATER HEATER SH SHELF A BUILDING DIVISION CL CENTERLINE BHT SHEET - n PARTITION TYPE INDICATOR Seattle, WA 98121 M402S.A PLUMBING PLAN LEVEL 2 SOUTH ALT PROJECT It Shawn Stankewich CLG CEILING IBC INTERNATIONAL BUILDING CODE SHTG SHEATHING PUBLIC WORKS PERMIT #: PW19-0064 M501N HVAC PLAN LEVEL 1 NORTH CLKG CAULKING ID INSIDE DIAMETER SID SIDING PHASE 1 PERMIT#: D19.0180 T: 206 632 2038 M501S HVAC PLAN LEVEL 1 SOUTH CLO CLOSET IN INCHES SIM SIMILAR s1s} PHASE 2 PERMIT #: TBD E: shawn@sWftcompanycom M502N HVAC PLAN LEVEL 2 NORTH CUR CLEAR INCL INCLUDE (D) (ING) SL SLOPE FLOOR ASSEMBLY INDICATOR M502S HVAC PLAN LEVEL 2 SOUTH CMU CONCRETE MASONRY UNIT INCR INCREASE SLNT SEALANT PROJECT DESCRIPTION STRUCTURAL ENGINEER M502SA HVAC PLAN LEVEL SOUTH ALT COL COLUMN INSUL INSULATION SPEC SPECIFICATIONS CONSTRUCTION OF NEW, TWO-STORY FIRE STATION FOR 8 ON -DUTY STAFF M503N PIPING PLAN LEVEL 1 NORTH CONC CONCRETE INT INTERIOR SPRT SPORT FLOORING Swenson Say Paget (RUBBER)( ) AND FIRE ADMINISTRATION OFFICES, WITH ASSOCIATED SITE IMPROVEMENTS M503S PIPING PLAN LEVEL 1 SOUTH COND CONDITION INTM INTERMEDIATE SQ SQUARE WINDOW INDICATOR 2124 Third Ave, Suite 100 PERMITTED SEPARATELY. BUILDING TO HAVE DRIVE -THROUGH M504N PIPING PLAN LEVEL 2 NORTH CONN CONNECTION INTUM INTUMESCENT SST STAINLESS STEEL BAYS. SITE IMPROVEMENTS TO INCLUDE PARKING, NEW RETAINING WALLS, Seattle, WA 98121 M504S PIPING PLAN LEVEL 2 SOUTH CONST CONSTRUCTION INV INVERT STC SOUND TRANSMISSION CLASS UNDERGROUND STORMWATER DETENTION TANK, AND EMERGENCY Dan Morrow M504SA PIPING PLAN LEVEL 2 SOUTH ALT CONT CONTINUOUS STD STANDARDISTUD GENERATOR. T 206 443 06212 REVISIONS CONTR CONTRACTOR JST JOIST STIFF STIFFENER M601N MECHANICAL ROOF PLAN NORTH E: dmorrow@ssfengineers.com cr:ar-pes snap be made to the SCODe CORR CORRIDOR/GORRUGATEO JT JOINT STL STEEL M601S MECHANICAL ROOF PLAN SOUTH No CPT CARPET STOR STORAGE DOOR INDICATOR of wort, wnnour pno+ aporoval or the CT CERAMIC TILE L LONG/LENGTH STFNT STOREFRONT MECHANICAL ENGINEER M701 MECHANICAL DIAGRAMS Tukwila Building Division. CTR CENTER LAM LAMINATE STRUCT STRUCTURAL The Greenbusch Group, Inc. M702 MECHANICAL DIAGRAMS - NOT INCLUDED NOTE: Revislbns will require a new plan CUST CUSTOM LAY LAVATORY SUB SUBSTITUTE submittal and may include additional plan revi= CWP CLEAR WALL PANEL LE LAUNDRY FAN EXHAUST SUSP SUSPENDED 1900 W Nickerson St, Suite 201 LH LEFT HAND SYM SYMMETRICAL A Seattle, WA98119 M801 MECHANICAL SECTIONS - NOT INCLUDED M802 MECHANICAL SECTIONS - NOT INCLUDED D DEEP(DIM)/DRYER LIN LINEARILINEAL SYS SYSTEM John Greeniaw DE DRYER EXHAUST LOCN LOCATION T: 206 378-0569 M901 MECHANICAL DETAILS DEPT DEPARTMENT LP LOW POINT T TOP/TREAD/TOILET/TEMPERED E: johng@greenbusch.com M902 MECHANICAL DETAILS DETIDTL DETAIL LT LIGHT T & G TONGUE&GROOVE LAYOUT GRID M903 MECHANICAL DETAILS DF DRINKING FOUNTAIN LTG LIGHTING T STAT THERMOSTAT ELECTRICAL ENGINEER M904 MECHANICAL DETAILS DIA DIAMETER LVL LEVEL TIC TOP OF CURB M905 MECHANICAL DETAILS DIAG DIAGONAL TO TRENCH DRAIN TFWB Engineers, Inc, DICA DRILLED -IN CONC ANCHOR MATL MATERIAL TEL TELEPHONE 1200 Westlake N, Suite 509 DIM DIMENSION MAX MAXIMUM TEMP TEMPORARY/TEMPERATURE/ Seattle, WA98109 DIR DIRECTION MC MEDICINE CABINET TEMPERED - - GRID LINE Kevin Warteile DIV DIVISION MDF MEDIUM DENSITY FIBERBOARD THK THICK(NESS) ON DOWN MECH MECHANICAL THRU THROUGH T:206285 7228 OP DAMPROOFING MEMB MEMBRANE TO TOP OF E: keVtn@tf-wb.com DO DITTO MFR MANUFACTURER TOC TOP OF CONCRETE _ _ PROPERTY LINE DOM DOMESTIC MIN MINIMUM TOP OF CURB FIRE STATION SPECIALIST ARCHITECT DR DOOR MISC MISCELLANEOUS TOIL TOILET - - - - - - - - - - - - - - - - - TCAArchitecture DS DOWNSPOUT (EXTERIOR) MLDG MOLDING TOP TOPPINGITOP OF PLATE OVERHEAD LINE DW DISHWASHER MO MASONRY OPENING TOP OF PARAPET 6211 Roosevelt Way NE DWG DRAWING MOT MOTORIZED TOSF TOP OFSUBFLOOR Seattle, WA98115 MTD MOUNTED TOW TOP OF WALL -----'"------ CENTERLINE BdanHarris (E) EXISTING MET/MTL METAL TP TOP OF PAVEMENT T. 206 522-3830 E EAST TRANSL TRANSLUCENT E: bdan@tca-inc.com EA EACH N NORTH TRTD TREATED - - - - - - - - - - - - - - -1-HR FIRE RATED EL ELEVATION (N) NEW TV TELEVISION ELEV ELEVATOR NAT NATURAL FINISH TWP TRANSLUCENT WALL PANEL ELEC ELECTRICAL NEG NEGATIVE TYP TYPICAL - - - - - - ' - " -' ' - - INTERIOR AIR BARRIER f" 2 r I ' L(?C EMER EMERGENCY NIC NOT IN CONTRACT EMR ELEVATOR MACHINE ROOM NO or# NUMBER UL UNDERWRITERS'LABORATORY Reviewed and A V y'E,VQ EQ EQUAL NOM NOMINAL UNPIN UNFINISHED _..._..._..._..._..._..._... EQJ EARTHQUAKE JOINT NTS NOT TO SCALE UNOIUON UNLESS NOTED OTHERWISE AIR BARRIER �OI"c'Libsteantial r)y pj �DLa EQPT EQUIPMENT By B }{i ` �Bi1S EPL EMERGENCY PATHWAY LIGHTING OA OVERALL VAP VAPOR BARRIER l/f/ EST ESTIMATE; ESTIMATED OC ON CENTER VAR VARIESNARIABLE EW EACH WAY OD OUTSIDE DIAMETER VB VINYL BASE EXC EXCAVATED OFD OVERFLOW DRAIN VCT VINYL COMPOSITION TILE CONCRETE Date 9 9 EXH EXHAUST OH OPPOSITE HAND/OVERHEAD VENT VENTILATION EXIST EXISTING OHW ORDINARY HIGH WATER VERT VERTICAL EXP EXPOSED OPNG OPENING VEST VESTIBULE EXPAN EXPANSION OPP OPPOSITE VFY VERIFY EXT EXTERIOR OVHD OVERHEAD VIF VERIFY IN FIELD OWSJ OPEN -WEB STEEL JOIST VG VERTICAL GRAIN BRICK FAB FABRICATED OZ OUNCE VOC VOLATILE ORGANIC COMPOUNDS FB FLUSH BEAM VOL VOLUME REVIEWED FOR PC FIBER CEMENT COMPOSITE (P) PROPOSED VS VINYL SHEET/SHEET VINYL CODE COMPLIANCE FD FLOOR DRAIN P FIELD PAINTED VTR VENTTHROUGH ROOF j.. APPROVED FE FIRE EXTINGUISHER (NOT FACTORY FINISHED) 1 FF FINISH FLOOR! PAR PARALLEL W WESTMlIDEANASHER GWB FACTORY FINISHED PART PARTITION W/ WITH SEP 10 2019 FG FINISH GRADE PC PRECAST W/o WITHOUT FP FACTORY PRIME PAINTED PERF PERFORATED WAIN WAINSCOTC FS FEDERAL SPECIFICATION PERP PERPENDICULAR WC WATER CLOSET City Of Tukwila FEC FE CABINET PKG PARKING WD WOOD BUILDING DIVISION FIN FINISH(ED) PL PLATEIPROPERTY LINEIPLASTIC WDW WINDOW FLASH FLASHING PLAM PLASTIC LAMINATE WSEC WASH. STATE ENERGY CODE RIGID INSULATION IIE1:lVi:Ci FLEX FLEXIBLE PLYWDI VIOL WIRE GLASS FLR FLOOR PLY PLYWOOD WH WALL HUNG FOC FACE OF CONCRETE PNL PANEL WIND WINDOW �' TY �� Ts�i.��r 11 sl FOF FACE OF FINISH PNT PAINTED) WP WATERPROOFING) MEMBRANE AUG 2 0 2019 FDIC FURNISHED BY OWNER, POL POLISHIPOLISHED WR WATER REPELLENT INSTALLED BY CONTRACTOR PPL POLISHED PLATE WRB WEATHER RESISTANT BARRIER FIBER INSULATION I MIT CENTER FOIO FURNISHED BY OWNER, PR PAIR WS WEATHERSTRIP INSTALLED BY OWNER PREFAB PREFABRICATE(D) WT WEIGHT FOM FACE OF MASONRY PRELIM PRELIMINARY WWM WELDED WIRE MESH FOS FACE OF STUD PROJ PROJECTIPROJECTION PROP PROPERTY YD YARD DRAIN PROX PROXIMITY Lj SEMI -RIGID INSULATION 0 13S GENERAL NOTES RENDERING VICINITY MAP 1. ALL WORK SHALL BE IN COMPLIANCE WITH THE REQUIREMENTS OF THE 2015 INTERNATIONAL BUILDING CODE (IBC), 8. GRADING MUST BE STABILIZED BY OCTOBER 31. NO EXCAVATION TO BE PERFORMED BETWEEN OCTOBER 31 2015 WASTATE ENERGY CODE, 2015 INTERNATIONAL FIRE CODE, ANDALL OTHERAPPLICABLE CODES AND APRIL 1 WITHOUTAN APPROVED DRY SEASON GRADING EXTENSION LETTER FROM THE DEPARTMENT OF COMMUNITY DEVELOPMENT. 2. CONTRACTOR SHALL FIELD CHECK ALL DIMENSIONS AND VERIFY LOCATION OF WORK WITH THE ARCHITECTS. NO SCALE MEASUREMENTS SHALL BE USED AS DIMENSIONS FOR WORK. LARGER SCALED DETAILS AND 9. DESTINATION OF EXCAVATION SOILS TO BE DETERMINED. THE DEPARTMENT OF COMMUNITY DEVELOPMENT DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER. NOTIFY THE ARCHITECT WHENEVER DIMENSION WILL BE NOTIFIED OF DISPOSAL SITE AFTER CONFIRMATION BY EARTHWORK SUBCONTRACTOR. DISCREPANCIES ARISE. 10, DRAWINGS ISSUED FOR CONSTRUCTION PRIOR TO FINAL PERMITTING APPROVALARE SUBJECT TO REVISIONS. 3. CONTRACTOR IS SOLELYAND COMPLETELY RESPONSIBLE FOR CONDITION OF THE JOB SITE, INCLUDING VERIFY CONSTRUCTION DOCUMENTS CONFORM TO PERMIT DRAWINGS BEFORE PROCEEDING WITH WORK. SAFETY, PROTECTION OF THE PROPERTY, AND THE LIKE DURING PERFORMANCE OF THE WORK. NOTIFY ARCHITECT WHENEVER DISCREPANCIES ARISE. 4. CONTRACTOR SHALL PROVIDED METHODS, MEANS, AND FACILITIES REQUIRED TO PREVENT CONTAMINATION it. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, ELECTRICAL, MECHANICAL AND SIGNAGE WORK, OF SOIL, WATER OR ATMOSPHERE. 12, DIMENSIONS ARE TO: 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S WORK AND/OR SUPPLIED FACE OF MASONRY (FOM), ITEMS THATARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTS OR ARE NOT IN CONTRACT, BUTARE FACE OF CONCRETE (FOC), OR ATTACHED TO THE CONTRACTOR'S WORK. FACE OR STUD (FOS) UNLESS NOTED OTHERWISE (UNO) 6. BUILDING IS TO BE FULLY SPRINKLERED. DIMENSIONS INDICATED AS CLEAR (CLR) OR FINISH (FIN)ARE TO FINISH FACE. 7. ALL FURRED WALLS SHALL HAVE VERTICAL AND LATERAL DRAFTSTOPS PER IBC, 13. THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENTS THAT IN MY PROFESSIONAL JUDGEMENTARE APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCW 64.55.005 THROUGH 64.55.090. IRev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA 98188 Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA 98121 206 443 8606 206 4431218 www.weinsteinau.com 02019 WeinsteinA+U -These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation ofthafthitect. GREE,l WAs/I p 2 4 P k 22833 GiSTV Fssj(7NA1-��G V ct CHC to W LU u tA LU Z Q m 04 N U H 2 7RECEVED od Issue Mechanical Permit Date 8113/19 Sheet Title COVER SHEET Sheet Q a Uj LU 11"' 1 ARCHITECTURAL FULL SITE PLAN 0 1 Or 20' 40' SCALE: V = 20' V � t q IRev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA 98188 T Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA 98121 206 443 8606 206 4431218 www.weinsteinau.com ©2019 Weinstein A+U- These documents have been prepared specifically for the above named projecL They are net suitable for use on other projects or in other locations without the approval and participation of the Architect. 3300 REGISTERS ARCHITECT EDWARD WEINSTEIN State of Washington Issue Phase 2 Construction Permit Date 812J19 Sheet Tit1eARCHITECTURAL FULL SITE PLAN Sheet A001 Ln GC W Z U Ln W 0 Z Cie m N I— U W f- 2 U I I n' OF E i LOCKABLE 8 PERSON -GATE r IN FENCE JF 4 rn� SHORING WALL FAC W/SHOTCRE I FIREFIGHTER PARKING (2) RETAINING WALL O I j° =1 REAR APRON J t 1 I PTD STL FIXED JOLLAJ 1 0 I I SEE 1/A101N & 1/A201N SEE 1/A101S & 11A201S A�70 FIRE HYDRA E ON CONC PAD 1% / RESIDENTIAL PROPERTY EXISTING CHAIN LINK FENCE (LOCATIONAPPROX) NEW SECURITY FENCE TO REPLACE (E) CEDAR FENCE ENCLOSING SOUTH END OF YARD HT TO MATCH EXISTING CHAIN LINK FENCE RESIDENTIAL PROPERTY O r ---t ------ -- I I I I I I I 1 I --•----- -- 7.1 FRONTAPRON a —ROOF OVERHANG ABV I \\\\ \III Q I_ - J­ L..7 3/1 LINE OF % CANOPYABV DECKABV ® / ( UTILITY ENCLOSURE • . `• .• i ;' .` , • " POLE-MTD PIGHT FIXT i ( 1 OVERALL AL , OVERAL L �,. SEE ELEC 03 9 1 i 2 02 .. o ,..• ' FIREFIGHTER PARKING (14) I TRASH ENCLOSURE I GUARDRAIL o I EATCH BASIN PER CIVIL, TY-SEE LANDSCAPE { 00 .._.. ar o O I BELOW GROUND-.-.- j w _ .99 ------ DETENTION VAULT, t \ I T 9'H MTLARCH SCREEN W! �X\ �� J \ / ELEC SECURITY GATE / 97 _ SEE CIVIL r 4----------------------- (, I 9-0 9-0 9-0 91419-09-0 V.0.V.0.9-0 9-0 9-0 9-0 9.0 9-0 " .,. / �-.-'"--a-=_'..-' ,`. -, .,.....---.---- Vvvvti ® ....._ .... T - .. 93 94 i a a -. ---- U --- ------ -- - - - - - -- - - - - - ...... ...... ., __ ` ; OUSEKEEPING SLAB ~ -- - -- - 4ENERATORON, i �- i GREEN— THARCHITECTURAL9_ I EDESTRIANCONNECTION � POLE IJGHT, TYP -/- -- 115 TO CITY HALL PROPERTY 1 V/ �PC RETAINING WALL 003 I % CONCTRANSFORMER i � ULT PER PSE REQTS _ DEMO (E) CONC STAIRS ; ! / REGRADE AND PLANT � A F � 112 - .- _ SEE CC�L & LANDSCAPE Ap03 I i �� ' O -CITY OF TUKWILA PROPERTY / i" O `- % SOUND MENTAL HEALTH PROPERTY / — - - / V / �ql ENLARGED ARCHITECTURAL SITE PLAN o 81 W 24• SCALE:3132'= 1'-0" +ili I ' + ------------ I I f o 05 IIIIV�ti i / / do� / r >. , ml� �••�,•� G i / i -\\ .,`REVIEINE[)' OR CC'Dr COMP LANCE- - r APPROV D t ----------'-------------- - - i 'OLF iv LUIJ _ —... 90 G ty of Tu i _._8..9_.... - - - BIAIL ING DI 1 ION 1\ < Rev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA98188 IT Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA 98121 206 443 8606 206 4431218 www.weinsteinau.com 02019 WelnstalnMU -These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation of theArchitect• 3300 REGISTERS AR�C�H�I'TE.T EDWARD WEINSTEIN State of Washington Issue Phase 2 Construction Permit Date 8/2/19 Sheet Title ENLARGED ARCHITECTURAL SITE Sheet GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS - - - - - - - - -- - - - -- --- - ------- - _ -- NOTED OTHERWISE 3 REQ'D FIRE -RATED i CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) A A,5 FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEEA701 83'-3518" 7 DOOR SCHEDULE - SEE A911 MASONRYD/MS OVERALL BUILD 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE - SEE 5118" 51/8, A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY _- 20151BC '' 11'43/4" -'- 4'-10" 8'-31/2" _-_" 11'-5" 4'-61/4" 14'A3/4" 15'-10112" 11 �2'-1" --'- 118 --' --1'•71i4" 9'-9118" 111 116 - 115 GRIDS - - , -•••-•••-•••-INTERIORAIRBARRIER 2 NIP - A302 _ CLADDING LEGEND - CONTROL JOINT A321 `� �`r r\ 1 (�' BRICK WALL MM PULL \ ' DOWN EYEWASH X66 I II `rr rr 66 X6A \ \ \ � CJ, TY rr II rrr rr ------ ----- ------------------------- --- --- - - -- ----------- 0 0 , --- 8 - C`) CONIC SITE_J RETAINING WALL SEE CIVIL I FIXED BOLLARD 3 Z42,' I 8'-2 314" YFLAMG�iB �I' 10- L SSTO RAINED ------ CASCADE FILL ( FOIO) COUNTER & INTEGRAL I I! ' SINKW/BACKSPLASH I! ! I ( ! � y N STATION (FOC) i I N 1 I iDECbIV, III I'1 I �. 1341 FLR GRRA�TE TO 1 fD CONTINUE tINDERij1= EMS DRY 135 S 4 36 W A617 E SGBA m o N yo W A617 E S SHBP "� iNilil' CO NITER T-- - - - -�� S 7 cc�33� W A817 E fl A 0 WORKBENC X ROOFgCCESS -' HAT H ABV'i WALL MTD ADJ SHELVING !! A617 s t S S A 0 i UNO N X SERVICE SINK 0 X7B I FEC K p - - - - - - FEC 1 136B ---------------- .. __ 1 /— — — --- -- ---- ----- -- ---- -- ----- T X. " FLUSH FLR GRATE - - - TAREVDRAINBE� A323 6"STLBOLLAR ,W/DOOR CONTROLS -----I -�---'-__------'---1--------� 1 ' I I I ROOF OVERHANG ABV - I I � ' TRENCH DRAIN, TY i I -------------------�------- D—�Efl�_ O 6" STL BOLLAR - - _ _ � PROVIDE STRIPING ATAPP BAY T-'=-� - O LINE LOCATIONS TO BE MARKED 6" STL BOLLAR�, W/DOOR CONTROLS_ j ----- ---------------- - - - - -- ONSITEW/TFD I FTFTI I I I I EL-1111 1 I I i m -- i - FIXED BOLLARD 133 6"STL BOLLARD►{ --- - TYP OF 5 n_ FOUR -FOLD DOORS IN OPEN POSITION, TY J ' X2A - - - I - - 1 - N - - - - - - - - 1 - - i______ O 1-�-------------------------- W Z E 6"STLBOLLAR�,W/DOOR CONTROLS - --_ S 4'4 1/4" Jr - I 7 --- I i - I i 0 1 I - i I l A302 i � 6" STL BOLLAR --- _--------------- ____ ________________ ______J - -I- - BRACE FRAME, TYP FUTURE ELEC MAP 15' 91/8" SEE STRUCT PROVIDE ELEC AN 703 -{� BLOCKING t`%/ I X1A - - - - - - - - K 0 - FLUSH FLR GRA - - - - LINE OF AIR BARRIER CONTINUITY '--------------------------- ----------------------------- WIAREADRAINBE_ Ir AT INTERIOR PARTITIONS - - - - --- --- -- -__--- -- - _ _ ----__ -- _ --- -_� w E _-------- 12 8 62 - ,.''���NB � I�) I 15'-2318 6'-67/8" T-113/8" '-83t8" I 16'-21/" 1-0 -91/4° SF`' 0 6.4�11 r 1 a N CORRIDOR p �I 126E °? �- WALL MTD 11t 130.1 A611 N A 0 ' SHELVES STORAGE �� I A 0 GEAR WASH 1 I �. i"'• "- '" UNO , A 0 -128 f_MOVABLE GEAR 1 B 0 LOCKERS E �A 0 AD W� M 1306 - ./' -�'� ? II A� 614 Y } --- ___ — ._ .. FLUSH FLR RATE BATTERY COUNTER Wt !, 129 ( , - - - - © Wt AREA DR IN BEL ® -` OOT WA%H $ A 0 OVHD CABS & MULTI• d- AD OUTLET RACEWAY . cn C AIRLOCK i �N ; FLUSH FLR GRATE - N S ..BOOTH FLR GRATE I',,'! W�A61E Fo I, W<A61$�E WA AIRLO1 AREA FLUSCK BEL), Ivr 'a ----.-...--MIRROR ° � E TRACTOR ON l 126 � PHYS TRAIN y�—� O - -- �'*-- \. N A 0 WC �� SLAB V 1 ! I 124 AE18)E_--._._.-- WtAREADRAINBEL :II i ( WC $ - - - HOUSE EEPING 5 UNO �.; CURTAIN •� 12pA • N o AD A 0aF��� GEAR�BTOR! 1 FLOOR PLAN LEVEL 1 NORTH SCALE:114" = V-0" CONC SITE RETAINING WALL I " SEE CIVIL - - - - - - X78 � (M - - —� - - - - - - — I Ii i I i I I I i I I i i I I i r- ROOFO ERHANGABV I I! i I i I O i I I I I I ' I I 4n I I I I i I I I i1 N h I i 1 I I. I I I I I ' I / I I _ I I I I 1' i I I i I I I I i I� i I 1 I I I I 18 A301 ' REVIEWED FOR CODE COMPLIANCE 9'-3112" �- - - - SEP 10 2019 X1A City of Tukwila _ — — DIRtP'DIVIB — ' POST-MTD FDC I 1 ` A301 0 €1ECEIVED CITY OF i• IN ILA — AUG 2 0 2019 PERMIT CENTER X1A Rev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA98188 T Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA98121 206 443 8606 206 4431218 www.weinsteinau.com 02019 Weinstein A+U -These documents have been prepared specifically for the above named project They are not suitable for use on other projects or in other locations without the approval and participation of theArchitect. 3300 REGISTERE ARCHITECT ll EDWARD WEIN State of Washington Issue Phase 2 Construction Permit Date 8/2/19 Sheet Title FLOOR PLAN LEVEL 1 NORTH Sheet r'. 2 FIXED BOLLARD ---- --- - - - - ---- - - - - -� APP BAY TYP OF 5 - `� I R ® - - - 133 6" STL BOLLARD � -.. ---- - ------ FOUR -FOLD DOORS IN OPEN POSITION TYP----'y--- '•- . X2A I WA>E 6 STL BOLLARD, WIDOOR C0N1R0LS -_ - --61 D �- 1 � S , 4'-4 1I4" i 1'- ' I it I i . I fl_ _s�l II�C 1 T I ilt�Z ��1 ��� ICi I i I I I A302 ' A302 - 6" STL BOLIAR i - --------- ------------- - - - --' FUTURE ELEC MAP 9 BRACE FRAME, TYP PROVIDE ELEC AN t8.9 418" SEE STRUCT BLOCKING X1A K 0 FLUSH FLR GRAT LINE OF AIR BARRIER CONTINUITY _ _ - -_- - - - - -_- - _ _ WIAREADRAIN BE AT INTERIOR PARTITIONS 1P B W A 11 X1A I I 1'-0" O12f06R- Y CLEANS''-��' 15'-2 318' 6.6 718" T-11318" '•8 3/8" 16'-21/4" -91/4' D'S' 4 71 ' _' K 0 i _ N I 1 �FT� CORRIDOR ^ l i 6 "� 1288 t l l�WALL MTD 1A611 N . A O SHELVES STORAGE - -'�'--' �,- UNO ! A 0 GEAR WASH ! 9 A 0 128 MOVABLE GEAR WOE ( A 0 1 130B �' B 0 LOCKERS 1i' i A614 q ( FLUSH FLR RATE 0 129 �W/AREA D IN BEL 7 1 BATTERY COUNTER W/ I - m OOT WA%H: OVHD CABS & MULTI— I AD IN N �--FLUSH FLR GRATE A 0 'I OUTLET RACEWAY I `i� I I AIRLOCK I ! ,I I I W7AREA DRAIN BELI N �'� ASH 130 W�Al �FD 1��l W A 1 E AIRLOCKI MIRROR G 0 UFLUSH FLR GRATE �II 1 126 i 5 I t E (TRACTOR ON a •- -•-• _ A51 E_----,---.--L_ W/ AREA DRAIN BEL i WC HOUSE EEPING SLAB I 1 HY12 TRAIN N A 0 h P UNO 129 1 aD 2 CURTAIN TRACK1 n, ABV GEAR STOR A614 126A ! N - �_ 0 - - i' 127 FD -..._ W 6 E I I ( li I, l I l A613 ap I�. j AO 502 _77130A st' HANGING BAR SHELF A 0 S I - j WALLMTDTVABV STAIR 2 ...- ... -._ - - --..:-.__-...-_..- ..-... I RUBBER FLR TILES 'II ----• 1 oLL B 0 I. GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE - G101 - 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOG) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEEA701 7 DOOR SCHEDULE -SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE- SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015IBC AIR BARRIER CLADDING LEGEND V CONTROL JOINT ��� BRICK 11 I � — i POST-MTD FDC 1 A301 m� ( I A 0 HANGING BAR r (_ I j — - - - -! W/SHELFABV e B 0 I N LAUNDIJAN I CORRIDOR ' 117 °i i _WALL MTD GEAR 6 122 I n - -- I B 0 IV 9 E_� a $TOR LOCKERS - - - - - - - - - -4_13 O° OLD•DOWN PLUMB FOR MOP SINK'CORRIDOR FEC W/SSTSH LF,116 IRON BD S FUTURE W/D ABV iOPEN MTLICE MAKER, FOIC----r --- S SHELVING O H 0_CAPTBUNK - - - _ _ _ A 0 i WATER BOTTLEF 1 M 0 FILL STATIONLe *A424 _FIRE HYDRANT ELEV C RD� I ON CONC PAD —I A 0 �W A614 E ,N CNTRL RIEPL}ER k UNO 00FD ® FDA e RFD ® 9 F O I I' CL03ET i 1 i �A -1- - - - - - A450 v I BATH ADA EL OR - I TYP ^ I 118 AI BATH ao C 1 ' BATH 119 . ----- BATH s r r 4 I o A611 0 - -121 2'-51/2" N N �'iTAIR 1 BUNK - 14 N M 0 SOLID SURFACE I 11_4 A , ; COUNTERTOP Wt I B 1 I ( - - 9 I BACKSPLASH N g W� 40 _ �� _ - - - l XL TWIN BED 15 TYP OF 4) W A611 E A611 W A611 E I _ G 0 m O FRAME, TYP W A614 E S S SHAFT \ - S I A 1 — — — ——.—.—.—.._..._.—. _ -. . 116 119 120 121 1 B BUILT-IN WD BENCH �:. - - - - - - - - - - - - --•-•+•-•-• :-•�•-•- --.-.-.- -.--.-.-.-. .-.-. N D 1 FLUSH DOOR WITH ? 5 tl " 4- 6-6 " u 9'-01/2" 7-10112" 8'-87/8" 7/8" CORR v CONCEALED HARDWARE X2A - uU uu - _ - - - - - - - - —N- - - - - 2 - - - - h - - - - — u a v z 20 m �- +111'-0" =F.F.-m W 10 E N _ � CDR IDOR 4 2 ANGING BAR o MAI BOX & EMER EN Y PHONE M 3 A6t2 A 0 1 7 A614 A611 A 0 u^ W A612 E O S A323 I N°-STLCANOPYABV '7 BUNK 6 1 8'-9112" 6 UN N 2'-5 3/4" 6-0" 4'-3118" 51.0. 4'-3 /8" 5'-0" S 4' 31J8" 5'-0" ' 21-6 7/8. S VESTIBULE A322 106 _ NLOBB- A322- - -OR - W 10 ELj FLUSH ENTRANCE DR DER� lTIT1111111fTTTi,1I FLOORGRILLE�A613 B ILT-IN DISPLAY. UNIT SGLASS DOORS n 9-2 5J8" 1102 3 U UL E71 MTD ABV,"� GBLE E- — SS 16A, 111 TYP 110 I 109 v -F SHELF W/ HOOKS -! r r ` J BC BUNK r BUILT-IN SHIFT °—BEL, TYP p r 112 LOCKERS, TYPE p BUNK BUN 1 BUNK F 111 a 110 109- BUILT-IN DESK ^ X B i -1 C 1 T B 1 F& HEADB0AR16, C 1 TYP 9'-2 7/8" 3' 3 � A D ! 1 - - - - - -77- - - - - - o ; 116 OB X1A O O [j (D > 2fi'-3 5/8" 2' 8 38" 6'•3 5 8" 2'•8 318" 6'•3 5187 2'-8 318" o------- MO MO MO II-- - ----------------' ------1--------�I CARD READER DECK OVERHANG ABV 1 A301 STL CANOPY ABV— A3P8 I I I I I I I I I 1 I I I ! I I I I I I GRIDS MASONRY DIMS 1 FLOOR PLAN LEVEL 1 SOUTH___ SCALE:114" = 1'-0° cD 103 0 DtMm SPRINKIMECH 103 Q FD Drtvm I ---------------- --- H ARCH SCREEN I REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 City of Tukwila BUILDING DIVISION 7 7�� 1 ularu+r uun nrvu 108 ELEC 105 H0 I ( 104 10 W A611,E r — — — 1 L___ rl BUNK p 108 S H 0 C � C 1 C 1 ( 2 I I FD ADA WC 104 A617 ( C fill 9-7 718" 8'-7 5/8° IT I B 6'-3 518' 2'-8 318" 6'-3 518" 3'-8 " CT 0 ENCLOSURE I G � S METER I MO G2 I I I I 1 I H ARCH SCREE I I I I Rev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA98188 V./ Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA98121 206 443 8606 206 4431218 www.weinsteinau.com © 2019 Weinstein A+U -These documents have been prepared specifically for the above named project They are not suitable for use on other projects or in other faafions wNrout the approval and padidpation of the Architect. 3300 REGISTERS ARCHITECT EDWARD WEINSTEIN State of Washington Issue Phase 2 Construction Permit Date 8/2/19 Sheet Title FLOOR PLAN LEVEL 1 SOUTH Sheet All n.' i A A.5 A.7 B.1 MASONRYDIMS 51/8" GRIDS I' 11'4 3/4" 4'-10" T-3112" I I I I I I I I -1 F.1 V VLKHLL bUILU/N 511B" 14'-034' 16-101/2" 12'-1" 9'-91/8" P-71/4" A302 1 I I I I I 1 A321 I I I I I I CJ, TYP- GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE -SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 - - _ 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015ISO INTERIOR AIR BARRIER CLADDING LEGEND 4 CONTROL JOINT ®OO/� BRICK - -U- -U- -U- -U- -U- -U- _U -. I I I I I I X LOW ROOF MECH EQUIP, TYEX NS I VEHICLE SLOPEq I I EXHAUS EXHAUST EXHAUS EXHAN ST 114" =1'-0" 4✓✓ FAN fAN FAN R F NT CCESS ROOAHATCH - - - - O- - - - - - - - - - - - - - - - - - - - - - - -� - - - - - — _ - /- - - --------- — --------------------- -- ------ ------------ ----- - - - - - - - -- I_I - - - - - - - - - - - X 1 X10�1 1- - - - - - — N A323 13 1 ---1------------------ I------ I I ❑ it i I I 1 I 1 i 1 I II 1 I 1 I 1 I 1 I II I I I I I I 1 I I I 1 1 � 1 I 1 I I � II I I I I i I I I I I I 1 � r°t—ROOF OVERHANG ABV I I 13 I l I I - - - - - - - - - - -1 - - - - - - - - - - A6 - - - - - I - - -- ------- -----------,-----------'----------------------- - ❑ ' 1 I + + 1 I I 1 1 N I I 1 I I I i I I I i i I I I I I I I I I I II OL I � I I I I � i 1 I I I I I I I I i i I I i 1 I + + I II I I I I I I I -L_ _ I I 1 1 1 I I - ' ' ' - - - - - - - - - - - - - - - - I I 1 1 1 ❑ I I �____________1 SKYLIGHTABV,�_---__J I I I 1 TYP I i I 1 I I+ 1 i 1 I 1 1 I i II + I + I I + I 3 II I A302 I I 1 +�—OVHD DRS, TYP i i I I i 1 18 13 A30 � 10'-3518" 2'-8318' LINE OF AIR BARRIER CONTIN ITY - - - MO - - - - AT INTERIOR PARTITIONS K 0 - - - - - - - - - - - - - - - - - - XIA -- - ---- ----- ------ -I----=------_ -- -- - --- - - - —�- - - �-- - - - - - - 17Z — X1--- +. 16'-01/8" N ROOFACCESS 9 F ATCH ABV CPT OFFICE W�A621/ E A 0 1221 I `' t A301 - M UNO kn ad LU z V 0 LU 0 z Q 0 to H V h- S V Q Q nECEIVEtD / CITY OF TtiMILA Issue Phase 2 Construction Permit LU FLUSH FLOOR DOUBLE DUPLE RECEPTACLE � 1 AUG.20 2019 / -'-'------- -----' _� OUT Wt DATA. TYP OF 4 I �i-------------- Date 8l2/19ILA STATION OFFICE 222 JFLOOR PLAN LEVEL 2 NORTH _ sCALE:1/4" = V-0" FUTURE FIREADMIN SPACE. PR�UIDE CODE-REO'D EMERGENCY LIGHTING, SEE ELECT „ " , , , ,.,-*�--vv �r r�rarm-; r_•�_rrr,r-� amr;rn, -•r.rn , , T��rr-rn.-r ir-,ro ;rr - - v-i177, T77- - - _ X1B I' G 0 16'-01/8" �----a N ROCFACCESS CPT OFFICE W A621 E A O TCH ABV i A301 221 LINO i {` q S G1--- � N' FLUSH LOOR DOUBLE 4 6 —.—.—................. --� • DUPLE RECEPTACL ! 421 /• OUTLET W/ ILATA. TYP OF 4 m0 STATION OFFICE OGho I222 FUTURE FIRE ADMIN SPACE. PR VIDE CODE REQ'D EMERGENCY LIGHTING, SEE E EC I ( N B 0 2 S1 AIR k, W A621 E 502 ' - - - I u, S % rIry i STL GUARDDRAi� 621 WALL-MTD TV A I Al A \LL — — — \— — — — — — — — — — — — — — — — — — — — — \ - - - - - - - =REF REF REF FEC;A1 A 1 N - N - - 15 I VV PROVIDE WALL MTD B 1 A621 - - - - - - - - FIRE EXTINGUISHER- ----- ---ULL-HT CAB W/ADJ SHELVES S OFD I A 0313 A O 3" WC 5'-1 1t4" A O A O v SST SINK A622 ITCHEN ISLAND I 223 I A 1 M 0 /,i' - - - - - - -iL , - - - - - T- 4 32 LOCKABLE 1' 6" A 1 — - T2 1 FOOD LOCKERS & MIN 4 SHIFT LOCKERS H 0 I 222 C 16R 501 I� 1 ._._.- I i I I 4-2" H O COMM B 1 I A450 209 I S IR I 1 ® EL OR I -- -IL I 1 Ao � A622 A622 ®� TEMP BC �FD A 1 I I I i II T209 GASRANGE STL CANOPY BEL WIHOOD A B 1 ( _ _- - 209 _ BUILT-IN CAB A 0 - - - A 0�•� _ A 0 W/UPPERS D 1 1 •-•-•---•-•-•----.-.-._.-.-._. _ - - - - - - - - - - - - - FIRE EX - - - - - - - E WALL-MTD - - - - - - - - - - - FULL4IT CAB ACCESSIBLE - GREAT RM COFFEE BAR A FIRE EXTINGUISHER 1 I 6 I I I I I 16 6 A622 PLUMBED COFFEE A323 A322 MAKER, Fold 11 1 -- -___ yp___ __211A___Ii II-__-_______ I A322 E W A622 O 4b hU D 1 S pa la O A322 O qa �a G2 m y y DECK ii p 16 �M ya 231 li4 A322 �`� II 4 li 4 __=-_�__-_— -- ----_= STLBTRANSLUCENT_-ROOFDRAIN PANELCANOPYABV BEL DECK,CETERED I I N I I I I BUILT-IN CASEWORK X3 W 03 E WALL-MTD N G 0 3" S 3" X1B O O O Q X1B STLCHANNELABV 3'-3 8" 2'-8 318" 18'-4112" 5'-4 Y4" 2' 8 318" T-3 0" T.8 Y8" 7 3 518" T-8 318" 1 1V-3 5M 4'-8 3/8" 10'-3 518" MO\-_-TIREXDECKING----\,,,, MO MO X1B MO MO I STL CANOPY BEL 1 A301 i A323 I I I I I I I GRIDS 2'-0 S/8" 21'-91/4" 14'-2" 4'-6114" 20'-8" 11'-13/8" I 20'-0" V-71/4" MASONRYD/MS 96=3 N" OVERALL GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECKABV UNLESS NOTED OTHERWISE 3 REDD FIRE -RATED CONSTRUCTION SEE -G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE - SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 20151BC - - - -INTERIOR AIR BARRIER CLADDING LEGEND 0 CONTROLJOINT ® BRICK Rev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA 98188 Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA 98121 206 443 8606 206 4431218 www.weinsteinau.com © 2019 Weinstein A+U -These documents have been prepared specifically for the above named project They are not subbfe for use on other projects or In other bcations without the approval and participation of theArchitect. 3300 REGISTERE AR�CAH�I EREI, yV �W EDWARD WEINSTEIN State of Washington Issue Phase 2 Construction Permit' Date 8/2/19 Sheet Title FLOOR PLAN LEVEL 2 SOUTH -BASE', Sheet 1 I I L Z jf' o r3 --OVHD DRS, TYP 18 10'-3 518" 2'-8318" LINE OF AIR BARRIER CONTIN ITY AT INTERIOR PARTITIONS -1—K 0 X1A J ------------- - --- ------- ------- ---- ------------ 5'-0' G 0 16-0 118" L N RO S IT V 11'-0 112" CPT OFFICE E A 0 t HA A301 W4> LIN iv-0" F2 WALL-MTD TV S o ' CONIF ��FLUSH FLOOR DOUBLE F2175 UPLEX RECEPTACLE 14 I OUTLET W1 DATA C126,>, N N S k FLUSH LOOR DOUBLE E 6 ------ - .......... DUPLE RECEPTACL W4(;> \6L21J I A i� E ------- —4, X OUTLETW/ ATA.TYPOF4 TV I - A 0 S W4> T.� S STATION OFFICE Q BUILT-IN LOWER CABS 222 WICOUNTERTOPo I N EXPLR ACCES o �7ATCH AB G z b u N 214 r2R . .......... . . '\A �11 W IQ-21 E T-6- A 0 A-H S MIN "ALTERNATE 1: FLUSH ILOOR DOUBLE A 0 - - - - - - - UILMUT OF 2ND FLR DUPLEX RECEPTACLE N rio ADMINISTRATIVE SPACES -STL GUARDRAI 621 OUTLET W/ DATA. TYP OF 4 E i T A 0 E 9-441 1, WALL'MTD TV A 0 5 A 0 Al 7 A 0 9 W4(;> A 0 :FF S - - - - - - - - - - Z; -4 - - - - - - - - - - - - - - - - - GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE - G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE -SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE - SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015 IBC INTERIOR AIR BARRIER CLADDING LEGEND 17 CONTROL JOINT E� BRICK A 1 -10 1/4" !r ... ... N BACKUP EOCI TRAINING 5 REF RE FEC 210 _J I I L 13 15 FEC CHIEF 421 A621 211 212 Y BUILT-IN CAB W/ "n"t" F2017• 0 A 0 UP EOC-STOR- --MAKER, 10 BACK A 0 A I F GI -FULL-HT CAB W/ ADJ SHELVES FD L___ZL2 ___J WC A 0 A 0 13 4—SST SINK A622 12231 TABLE & CHAIR STOR 3' - - - - M-0- - - ....................... 1 211 ITCHEN ISLAND JA I - — - — - — - — - — -- + 64 . .... .. ......... 9 32 LOCKABLE '.6 H 0 A I Mil, FOOD LOCKERS 4 SHIFT LOCKERS D CORR 501 0.- J F2-fl '�r�H 0 Comm B I D 1� FULL HT U F_209� KITCHEN SUPPLY CAB� S�IR ISLAND ELIE OR 0 P'q _8_0 !? N S F A I E 13 1 bztl E� ❑ A I GAS RANGELUNCH 625 B I W/ HOOD F 2067 N S 208 S r201 L CANOPY BEL A' I BUILT-IN CAB 209 W1- — -------- ................. UPPERS ------- A I Rev Date Issue - — - — - — - — - — --- - -4—FULL-HT CAB is' 9-4 70 8.91/2" L E — - — - — - 51 ACCESSIBLE Bu�,L_ _.INCABI��12 2' GREAT RM S COFFEE BAR 'W/UPPERS CORR 1 224 16 Tukwila Fire Station 52 I I F2-1-7-1 A 0 PARTIAL HT A323 15447 65th Ave S PLUMBED COFFEE 0 91-9 31r 9'-9 112' A I �!LWICOUNTER N MAKER, FOIO FEC Tukwila, WA 98188 205 214 - ---------- I,,,- R -E—EE -------- ---- -------------------- 27 11 1A T 1 1 1 ��22 W4� �622 E S N A 0 �22 Q_ ADMINI SUPPORT COFFEE F REF IF T L V JD ELEOR 120F I IF ST ts I � E ASST CHIEF ASST TO FIRE CHIEF F77y5TO _ DECK ed W<;> 416 G2 iN114 231 S A 0 N A 0 FProject No. 17012 �22 BC W118. 9-2' _J X3 F20­51 <;> Weinstein A+U STIL & TRANSLUCENT� OF DRAIN S Architects & Urban Designers BEL DECK, CE q ER PANEL CANOPYABV N 2200 Western Ave Seattle, WA 98121 BUILT-IN CASEWORK WE 206 443 8606 WALL-MTD TV--7 3"- 44� S 3. G 0 2064431218 I www.weinsteinau.com - - - - - - - - - - --- - -------------- L: ----------- __J 9 2019 Weinstein A-Ll -These documents have been prepared specifically for the above named project. They are not sultab for use on other projects orin F other locations without approve an Pa c Palo STLCHANNELABV I of the Architect. to 18 1 1 54 314 2-8 318" A Y�3 5hi 2'8&8' '4 1/2" ! 1 P-3 51l 2.8 18" 7�1 A/A. 91 18� 11-3 518' 1-8 318" 10'-3 N" GRIDS MASONRYDIMS MO EX DECKING-----,,, I MO MO I , MO L - - - — — — — -- STL CANOPY BEL--/ 141 21'-91/4* 4-6 1/4' 20'-8" IT-1 3/8" 20'-0' 2'-0318" 96-3 &8' 31 OVERALL U 101 N PECEIVEC) CITY OF TUKWILA Issue Phase 2 Construction Permit LU AUG 2 0 2019 Date 812119 PERMIT CENTER z Sheet Title FLOOR PLAN LEVEL 2 1 A FLOOR PLAN LEVEL 2 SOUTH - ALT ) SCALE: 1/4" = V-0" P A A.5 MASONRY DIMS 83-3 518" OVERALLBUILDIN 51/8° GRIDS 11'43/4" * 4'-10" 8'-31/7 + N'-5" 4'-61/4" 14'-03/4" 15'-101/2" 12'-1" A302 GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE- G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) F.1 FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEE A701 7 DOOR SCHEDULE -SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE - SEE 51/8" A901 10 PROVIDE DRAFTSTOPPING AND FIRESTQPPING WHERE REQUIRED BY 2015 IBC 9118" V-71/4" ----—-—INTERIOR AIR BARRIER CHANNEL FASCIA Rev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA 98188 T Project No. 17012 Weinstein A+U _ _ _ _ _ Architects & Urban Designers 2200 Western Ave Seattle, WA 98121 206 443 8606 206 4431218 www.weinsteinau.com © 2019 Weinstein A+U -These documents have been prepared specifically for the above named project They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. tfi 1 A301 1 ROOF LEVEL NORTH SCALE:1W = V-0" YSheet ,, id Oe,\�p��� GOe OQ\QF� — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — - — - — - — - — ---- L ------------ - - - - - - - - — - — - — - — - — -- I "------------------ --------' ------- ----, I I R FACCESS HATCH 1 , SL.q OFE �m SLR OPE SLOPE _ A301 i i 1/4" = V-0" O00 1/4" =1'-0" l 9T A O 0 I ; �y'A; l � X, 93i�2 2 --- b ' H MECH SCREEN , 422 ; i i FUTURE PVARRAY i /mow i I RHRV I I Amp, TX5' WALK PADS, TYP y yjo°i qT0 I ' i I AQp /OTC I , �oefko 28 ��OG i - i i ROOF VENT ; : ODU1 ODU2 '.. i ' � i ; ROOF VENT -- - - - - - - - - -- - - - - - - - - - - - 1 A450 � , , SCUPPER AND DOWNSPOUT KITCHE HOOD I i [�ROTF] I VENT FAHAUN 1/4LOP 0" ' SAT VENT I p I I I 1iy,F IDU i ROOF i SLOPE VENT ; i i i ROOF SLOPE VENT !V0Et1T/1/,/,r O1/'c� 4" = V-0" i 'r O ® 114" = V-W 6 A322 O i O — — — — — t1 A322 i W'L i II _-•-' II _ �i7" WIZ — , � I w 4 O n , v, g 9T�1 1p ; 10 9,pg9y tic ; I I 16 i �d•AFi` ' s' A322 CANOPY BEL _nl I I I L____________________________________________ I OPEKJaDECK -BE OW—. ,,. I I I I I I I I ?p9T2! OOA 6'" �1A2yC I 29T °TopCo �9e9"Yq y0 I 3 A301 A323 I I I I I DECK BEL I I I I 1 I I I PTO STL CHANNEL FASCIA I I I i I I I I I I I I ��QCF I l ?'9T OOp A d,9 y� A2G �A FT P ,1.o `V° ROOF VENT I 1 1 1 ELEVATOR PENTHOUSE I I I I SLOPE 1/4" =1'.0" 16 1 p p F A323 1p 9p — — — — —��� STC'OA — — — —- I I A322 'u+ @ c6� F� GRIDS 2=0 3/8" 21'-91/4" 14'-2" 4'-61/4" 20'-8" 11'-13/8" I 20'-0" V-71/4" 2'-0 3/8" MASONRY DIMS 96=3 518" OVERALL REVIEWED FOR CODE COMPLIANCE r APPROVED kP 10 2019 3 City of Tukwila BUILDING DIVISION nECEIVED CITY OF T I,S'siWILA AUG 2 0 2019 PERMIT CENTER GENERAL NOTES 1 FOR ABBREVIATIONS, SEE G001 2 ALL INTERIOR PARTITIONS EXTEND TO BOTTOM OF DECK ABV UNLESS NOTED OTHERWISE 3 REQ'D FIRE -RATED CONSTRUCTION SEE -G101 4 DIMENSIONS ARE TO: FACE OF STUD (FOS) FACE OF MASONRY (FOM) FACE OF CONCRETE (FOC) UNLESS OTHERWISE NOTED 5 EXTERIOR ASSEMBLIES - SEE A401 6 INTERIOR WALL PARTITION TYPES - SEEA701 7 DOOR SCHEDULE -SEE A911 8 WINDOW SCHEDULE - SEE A411 9 ROOM FINISH SCHEDULE -SEE A901 10 PROVIDE DRAFTSTOPPING AND FIRESTOPPING WHERE REQUIRED BY 2015IBC - - - -INTERIOR AIR BARRIER Rev Date Issue Tukwila Fire Station 52 15447 65th Ave S Tukwila, WA 98188 T Project No. 17012 Weinstein A+U Architects & Urban Designers 2200 Western Ave Seattle, WA 98121 206 443 8606 206 4431218 www.weinsteinau.com m 2019 Weinstein A+U -These documents have been prepared specifically far the above named project They are not suitable for use on other projects a In other locations without the approval and participation of the Architect. 3300FREGI'STERE �IITEC�TI VV'NJ EDWARD WEINSTEIN State of Washington Issue Phase 2 Construction Permit Date 8/2/19 Sheet Title ROOF PLAN SOUTH Sheet 1 3 to ce LU V LA LIJ Z ca m ce to f— u W H u OC El -J R L l; I ABBREVIATIONS LEGEND DRAWING INDEX GENERAL NOTES AC AR CONDITIONING SYMBOL AM DESCRIPTION SYMBOL ABBE DESCRIPTION M001 ABBREVS, LEGEND, NOTES & INDEX 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS ACU AIR CONDITIONING UNIT IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL AD ACCESS DOOR, AREA DRAIN = ALIGNMENT GUIDE X DETAIL OR SECTION CALLOUT M002 MECHANICAL SCHEDULES SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR ADA AAV AMERICANS WITH DISABILITIES ACT AIR ADMITTANCE VENT ANCHOR XX SHEET WHERE SECTION OR DETAIL SHOWN M003 MECHANICAL SCHEDULES SYSTEM OPERATION. AFF ABOVE FINISHED FLOOR PIPE ELBOW DOWN 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT ALTN ALTERNATE 0 PIPE ELBOW UP DIRECTION OF CUTTING PLANE M004 MECHANICAL SCHEDULES SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND APPROX APPROXIMATE -- SECTION CUT LINE SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE ENGINEER. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING ARCH ARCHITECT --ti-- FLANGE M101 MECHANICAL SITE PLAN - NOT INCLUDED THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. ARV ACID RESISTANT VENT ARW ACID RESISTANT WASTE FLEX CONNECTION SD-X DIFFUSER OR GRILLE TYPE M201N MECHANICAL FOUNDATION PLAN NORTH 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM ASHRAE AMERICAN SOCIETY OF HEATING _D_ TEE OUTLET UP XXX CFM AMOUNT (CUBIC FEET PER MINUTE) PLANS. REFRIGERATION AND AIR CONDITIONING ENGINEERS M201S MECHANICAL FOUNDATION PLAN SOUTH BDD BACKDRAFT DAMPER _ TEE OUTLET DOWN DIRECTION OF FLOW 4. DIMENSIONS SHOWN FOR DUCTWORK WITH SOUND LINING SHALL BE NET FREE DIMENSION WITH SOUND LINING INSTALLED. SOUND LINING SHALL BE 1" THICK BFF BELOW FINISHED FLOOR t AIR VENT M300 FIRE PROTECTION ABBREVS., LEGEND, NOTES & INDEX UNLESS OTHERWISE NOTED. BOD BOTTOM OF DUCT ® OR EQUIPMENT ITEM XX BTUH BRITISH THERMAL UNITS PER HOUR �ID AAV AUTOMATIC AIR VENT M301N FIRE PROTECTION DIAGRAM LEVEL 1 NORTH 5. PENETRATIONS THROUGH ROOF OR EXTERIOR WALLS SHALL BE SEALED WEATHER TIGHT. PENETRATIONS THROUGH CEILING OR INTERIOR WALLS SHALL BE CD CEILING DIFFUSER LINE, ARCHITECTURAL BACKGROUND SEALED SUBSTANTIALLY AIR TIGHT. BELOW GRADE WALLS OR SLABS SHALL BE SLEEVED AND SEALED WATERTIGHT. CFM CUBIC FEET PER MINUTE BALANCING VALVE M301S FIRE PROTECTION DIAGRAM LEVEL 1 SOUTH CIRC CIRCULATING 1®� BALL VALVE LIGHT LINE, EXISTING 6. CONFINE THE APPLICATION OF FLEXIBLE DUCTWORK TO LOCATIONS INDICATED BY THE CONTRACT DOCUMENTS. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK CO CLEAN OUT M302N FIRE PROTECTION DIAGRAM LEVEL 2 NORTH SHALL NOT EXCEED SIX FEET. COND CONDENSATE BUTTERFLY VALVE HEAVY LINE, NEW WORK CONT CONTINUA11ON M302S FIRE PROTECTION DIAGRAM LEVEL 2 SOUTH 7. PROVIDE ALL REQUIRED ELECTRICAL POWER, MOTOR STARTERS AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORD COORDINATE N- CHECK VALVE 0 ROUND DUCT DIAMETER COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. COTO CLEAN OUT TO GRADE -I CLEAN OUT M302S.A FIRE PROTECTION DIAGRAM LEVEL 2 SOUTH - ALTN CW COLD WATER X PLAN OR HORIZONTAL DIMENSION B. PROVIDE ALL REQUIRED EQUIPMENT GUARDS AND STRUCTURAL SUPPORT AS RECOMMENDED BY EQUIPMENT MANUFACTURERS TO SUPPORT EQUIPMENT AND DEG DEGREE 0 FCO CLEAN OUT - FLOOR X/Y Y ELEVATION OR VERTICAL DIMENSION M401N PLUMBING PLAN LEVEL 1 NORTH TO ASSURE SYSTEM PERFORMANCE AND SAFE OPERATION. COORDINATE PRIOR TO INSTALLATION. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN DIA DIAMETER ----II WCO CLEAN OUT - WALL EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE FIRE RATING WITH THE ARCHITECTURAL DOCUMENTS. DIM DIMENSION ' A' � i i i i M401S PLUMBING PLAN LEVEL 1 SOUTH DN DOWN D<t GATE VALVE 9. COORDINATE LOCATION OF ALL THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT WITH THE ARCHITECT. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR DS DOWNSPOUT GLOBE VALVE I11 EXISTING WORK TO BE REMOVED M402N PLUMBING PLAN LEVEL 2 NORTH REFERENCE ONLY. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL ELEVATIONS. IF NOT SHOWN ON ARCHITECTURAL ELEVATIONS, MOUNT NO HIGHER DWG DRAWING THAN 44" AFF. E EXISTING HB OR WH HOSE BIBB OR WALL HYDRANT M402S PLUMBING PLAN LEVEL 2 SOUTH EA EACH, EXHAUST AIR -S S-- BREAK IN PIPE OR DUCTWORK 10. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. BUILDING AND STRUCTURE IS DESIGNED TO SUPPORT EQUIPMENT, BUT NOT DETAILED TO ELEV, EL ELEVATION JID INDIRECT DRAIN M402S.A PLUMBING PLAN LEVEL 2 SOUTH - ALTN ACCOMMODATE EACH AVAILABLE EQUIPMENT CONFIGURATION OR MANUFACTURER. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT EAT ENTERING AIR TEMPERATURE T INSTRUMENT TEST CONNECTION t/ FLAG NOTE NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. EG EXHAUST GRILLE IM® M501N HVAC PLAN LEVEL 1 NORTH ESP EXTERNAL STATIC PRESSURE L<J MODULATING VALVE 11. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. EWT ENTERING WATER TEMPERATURE T PETE'S PLUG (TEST CONNECTION) i Q REVISION NOTE M501S HVAC PLAN LEVEL 1 SOUTH EXIST EXH EXISTING EXHAUST PLUG VALVE AREA CLOUDED CONTAINS M502N HVAC PLAN LEVEL 2 NORTH 12. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. EXP EXPANSION CHANGES TO DRAWINGS 13. PROVIDE MINIMUM OUTSIDE AIR PER WASHINGTON ADMINISTRATIVE CODE REQUIREMENTS. F FAHRENHEIT SUBSEQUENT TO PREVIOUS ISSUE M502S HVAC PLAN LEVEL 2 SOUTH FC FORWARD CURVED PRESSURE GAGE 14. SHUT OFF FOR SMOKE CONTROL: PROVIDE SMOKE DETECTORS FOR AUTOMATIC FAN SHUT DOWN IN AIR CONDITIONING UNITS IN ACCORDANCE WITH THE FCO FLOOR CLEANOUT PUMP (DIRECTION SHOWN BY ARROW) -.- DN ON DUCT OFFSET DOWN IN M502S.A HVAC PLAN LEVEL 2 SOUTH - ALIN INTERNATIONAL MECHANICAL CODE (IMC). FD FIRE DAMPER, FLOOR DRAIN FLOW DIRECTION 2015 WASHINGTON STATE ENERGY CODE I/" FDC FIRE DEPARTMENT CONNECTION PRESSURE REDUCING VALVE M503N PIPING PLAN LEVEL 1 NORTH FFE FINISHED FLOOR ELEVATION ID DUCT OFFSET IN FLA FULL LOAD AMPS PRESSURE RELIEF VALVE -�- UP Up FLOW DIRECTIONN M503S PIPING PLAN LEVEL 1 SOUTH FDIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FPM FEET PER MINUTE ->yl- SITE GLASS DUCT WITHOUT SOUNDLINING M504N PIPING PLAN LEVEL 2 NORTH 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE FT FOOT, FEET C403.2.3(1)A,(i)B,(1)C,(2),(3),(4),(5),(7),(8),(9) OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. G GA NATURAL GAS GAUGE SOLENOID VALVE SINGLE LINE DUCT W INTERNAL LINING / M504S PIPING PLAN LEVEL 2 SOUTH 2, PROVIDE DEADBAND BETWEEN HEATING COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION C403.2.4.1.2 OF THE WSEC OR AS GAL GALLONS m M504S.A PIPING PLAN LEVEL 2 SOUTH - ALTN DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. GALV GALVANIZED THERMOMETER DUCT WITH INTERNAL LINING GC LAB GAS COCK ACOUSTICAL LINING M601N MECHANICAL ROOF PLAN NORTH 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2.1 OF THE WSEC AND AS GPM GALLONS PER HOUR [! THREE WAY VALVE INDICATED ON THE CONTRACT DOCUMENTS. GRD GRILLES, REGISTERS, AND DIFFUSERS FLEXIBLE CONNECTION M601S MECHANICAL ROOF PLAN SOUTH GWB GYPSUM WALL BOARD `' OR FLEXIBLE DUCT 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED HP HORSEPOWER TWO WAY VALVE pR M701 MECHANICAL DIAGRAMS BY SECTION C403.2.8 OF THE WSEC. DUCT TAPE NOT ALLOWED. HVAC HEATING, VENTILATION AND AIR COND1110NING UNION FLEX FLEXIBLE DUCT HW HOT WATER M702 MECHANICAL DIAGRAMS - NOT INCLUDED DUCTWORK STATIC PRESSURE AND SEAL CLASS: HWC HOT WATER CIRCULATION l VENTURI FLOW VALVE RA/EA RETURN AIR DUCT/RETURN DUCT UP WATER COLUMN SEAL GLASS HWG HWR HIGH WALL GRILLE HOT WATER RETURN WYE STRAINER WITH VALVE M801 MECHANICAL SECTIONS - NOT INCLUDED Ys TO 3 INCHES SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS HWS HOT WATER SUPPLY --+fir-- WYE STRAINER© RG RETURN AIR GRILLE M802 MECHANICAL SECTIONS - NOT INCLUDED ABOVE 3 INCHES SEAL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS ID INDIRECT DRAIN, INSIDE DIAMETER IE INVERT ELEVATION '�'�- RPBP REDUCED PRESSURE -I-► SA SUPPLY AIR OUTLET, SIDEWALL M901 MECHANICAL DETAILS 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8.1 AND C403.2.8.2 OF THE WSEC AND AS DESCRIBED IN SECTION 230700 OF THE IH INSTANT HOT WATER DISPENSERS BACKFLOW PREVENTER PROJECT MANUAL. IN INCH ® SA SUPPLY AIR DUCT/SUPPLY DUCT UP M902 MECHANICAL DETAILS KW KILOWATT, (1000 WATTS) OV�<I- DCVA DOUBLE CHECK VALVE ASSEMBLY DUCT TYPE LOCATION R-VALUE LAT LEAVING AIR TEMPERATURE DDCVA DOUBLE DETECTOR CHECK VALVE M903 MECHANICAL DETAILS LR LINEAR RETURN *>i- F RA/EA RETURN AIR OR EXHAUST AIR DUCT LWG LOW WALL GRILLE RPBP REDUCED PRESSURE M904 MECHANICAL DETAILS R-8, CLIMATE ZONE 4 (INCLUDE SUPPLY/RETURN EXTERIOR LWT LEAVING WATER TEMPERATURE BACKFLOW PREVENTER a SD SUPPLY GRILLE OR DIFFUSER APPROVED WEATHERPROOF BARRIER) R-12 CLIMATE ZONE 5 (INCLUDE MAX MBH MAXIMUM 1000 BTU PER HOUR WITH FUNNEL DRAIN OPEN AREA INDICATED ACTIVE ELEMENTS M905 MECHANICAL DETAILS APPROVED WEATHERPROOF BARRIER) (4 WAY IF HATCH IS NOT SHOWN) MCA MFG MINIMUM CIRCUIT AMPS MANUFACTURER ® FD FLOOR DRAIN O LINEAR DIFFUSER SUPPLY/RETURN/OUTSIDE AIR UNCONDITIONED SPACE R-6 MIN MINIMUM MOUNTING ® FS FLOOR SINK EA EXHAUST AIR DUCT/EXHAUST DUCT UP OUTSIDE AIR (<2,800 CFM SUPPLY WITHIN CONDITIONED SPACE (NOT CONSIDERED R-7 (DAMPER AT ENVELOPE NC NORMALLY CLOSE ---CW--- CW COLD WATER UNIT) PART OF THE BUILDING ENVELOPE) PENETRATION) NIC NFPA NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION ----HW---- HW HOT WATER EG EXHAUST AIR GRILLE OUTSIDE AIR(>2,800 CFM SUPPLY WITHIN CONDITIONED SPACE (NOT CONSIDERED MUST INSULATE TO ENVELOPE NG NATURAL GAS -----HWC----- HWC HOT WATER CIRCULATION UNIT) PART OF THE BUILDING ENVELOPE) REQUIREMENTS OF CHAPTER C402 NO NT NORMALLY OPEN NEUTRALIZATION TANK W W WASTE TRANSITION - RECTANGULAR TO ROUND SUPPLY WITHIN CONDITIONED SPACE R-3.3 NTS NOT TO SCALE ---- V ---- V VENT OA OAT OUTSIDE AIR OUTSIDE AIR TEMPERATURE ----0---- VTR VENT THROUGH ROOF - RECTANGULAR ELBOW WITH TURNING VANES 6. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.9 OF THE WSEC AND AS DESCRIBED IN SECTION 220700 AND 230700 OF THE PROJECT OC OBD ON CENTER OPPOSED BLADE DAMPER CWS CWS CHILLED WATER SUPPLY 90' (R/D OR R/W=1.5) MANUAL: ORD OVERFLOW ROOF DRAIN - - CWR - - CWR CHILLED WATER RETURN MINIMUM PIPE INSULATION THICKNESS OS&Y OUTSIDE STEM AND YOLKPH PHASE FOS FOS FUEL OIL SUPPLY SYSTEM/TEMP ('F) INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER REVIEWED FOR PSI POINT OF CONNECTION - -FOR ^ - FOR FUEL OIL RETURN �7ss 90' ELBOW TAKE -OFF WITH 45' TAPER CODE COMPLIANCE CONDUCTIVITY MEAN RATING < 1" 1" to 1-1/2" 4" to ? 8 PSI PW POUNDS PER SQUARE INCH PRESSURE WASTE HWS HWS HEATING WATER SUPPLY x BTU - in./(h • ft' • F') TEMPERATURE, 'F < 1-1/2" to < 4" < 8" , APPROVED RA RG RETURN AIR RETURN GRILLE _ - HWR - - HWR HEATING WATER RETURN 90' CONICAL TAKE -OFF ( HEATING > 350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 SEP 10 2019 RH ROOF HYDRANT RWL RWL RAINWATER LEADER 0 CARBON MONOXIDE SENSOR 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 j RL RAIN LEADER 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 1 RD ROOF DRAIN ORL ORL OVERFLOW RAINWATER LEADER 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 city of Tukwila REF REFERENCE - - RS - - IRS REFRIGERANT SUCTION 0 CARBON DIOXIDE SENSOR 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 BUILDING DIVISION COOLING 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 REQD REQUIRED RG RETURN GRILLE RL RL REFRIGERANT LIQUID $ SWITCH < 40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 RPM RPBP REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER C C CONDENSATE DRAIN OR THERMOSTAT 7, SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES EXCEPT SA SD SUPPLY AIR STORM DRAIN, SUPPLY DIFFUSER G G NATURAL GAS EQUIP - TO EQUIPMENT LOCATION WHERE PERMITTED IN SECTION C403.2.4.1 OF THE WSEC. SG SUPPLY GRILLE SS SS SANITARY SEWER S O SENSOR 8. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM AS REQUIRED BY SECTIONS C403.2.11.3 AND C403.2.14 OF THE WSEC FOR FULL LOAD✓ SHT SHEET F F FIRE PROTECTION WATER ® HUMIDISTAT EFFICIENCIES. SM SHEET METAL SO SCREENED OPENING A A COMPRESSED AIR ® GAS RESET BUTTON SP STATIC PRESSURE r PIPE SIZE REDUCTION 9. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C103.6.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION SPD STATIC PRESSURE DROP AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A SPEC SPECIFICATIONS --DN PIPE SLOPE DOWN THIS DIRECTION I BDD BACK DRAFT DAMPER MINIMUM. TDH TG TOTAL DYNAMIC HEAD TRANSFER GRILLE PIPE CAP FIRE DAMPER, 10. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS SPECIFIED AND PER SECTION C103.6.2 TOD TOP OF DUCT Q GAS COCK FD WALL OR CEILING / TPD TOTAL PRESSURE DROP LL11 11. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC." TSP TOTAL STATIC PRESSURE TYPICAL FSD FIRE AND SMOKE DAMPER 12. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING SHALL BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE WSEC. V VOLT, VENT COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, TRAINING, VD VOLUME DAMPER REPORTS AND ACCEPTANCE. SUBMIT COMMISSIONING COMPLIANCE CHECKLIST TO BUILDING OFFICIAL UPON COMPLETION. VTR VENT THRU ROOF VD VOLUME DAMPER W WASTE 13. CONTROL SYSTEM SHALL PROVIDE 7 DAY PROGRAMMING AND SETBACK CAPABILITY, OPTIMUM START, THERMOSTAT INTERLOCK AND TEMPERATURE RESET. WB WET BULB TEMPERATURE - MOD MOTOR OPERATED DAMPER SYSTEM TO COMPLY WITH SECTIONS C403.2.4.2 AND C403.2.4.3 OF THE WSEC. W/ WITH WC WATER CLOSET 14. PROVIDE HOT WATER HEATERS WITH MINIMUM R-10 INSULATION PAD UNDER THE TANK. WCO WG WALL CLEAN OUT WATER GAUGE t� CLEARANCE REQUIREMENT 15. PROVIDE AUTOMATIC SHUTOFF FOR ALL DOMESTIC WATER CIRCULATION PUMPS. SEE ALSO SPECIFICATION SECTION 230900. CITY OF TUI 1 WH WHA WALL HYDRANT WATER HAMMER ARRESTER FILTER 16. RESET HEATING AND COOLING TEMPERATURES AUTOMATICALLY PER SECTION C403.4.4.4 OF THE WSEC. SEE ALSO SPECIFICATION SECTION 230900. WSEC WASHINGTON STATE ENERGY CODE AUG 20 2 ' 17. PROVIDE ISOLATION VALVES FOR ALL EQUIPMENT CONNECTED TO FLUID PIPING. 18. MECHANICAL SYSTEM EQUIPMENT SIZING COMPLIES WITH ENERGY CODE COMPLIANCE LIMITS SECTION C403.2.1 AND C403.2.2.1--l' PERMIT CE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED 19. DAMPERS SHALL COMPLY WITH WSEC C403.2.4.3, INCLUDING DAMPERS INTEGRAL TO HVAC EQUIPMENT, AND SHALL HAVE A MAXIMUM LEAKAGE RATE WHEN TESTED IN ACCORDANCE WITH AMCA STANDARD 500 OF: A. MOTORIZED DAMPERS: 4 CFM/FT2 OF DAMPER AREA AT 1.0 INCH W.G. B. NON -MOTORIZED DAMPERS: 20 CFM/FT2 OF DAMPER AREA AT 1,0 INCH W.G., EXCEPT THAT FOR NON MOTORIZED DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION: 40 CFM/FT2. 20. THE HVAC SYSTEM AND ITS CONTROLS SHALL ALLOW ECONOMIZER OPERATION WHEN MECHANICAL COOLING IS REQUIRED SIMULTANEOUSLY. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD. HIGH -LIMIT SHUTOFF CONTROL FOR AIR ECONOMIZER SHALL BE SET WHEN OUTSIDE AIR TEMPERATURE IS HIGHER THAN 757. 21. ALL DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6 PERCENT OF THE FAN FLOW IF THE DUCT SYSTEM:(/ A. IS CONNECTED TO A CONSTANT VOLUME, SINGLE ZONE, AIR CONDITIONER, HEAT PUMP OR FURNACE; AND B. SERVES LESS THAN 5000 SQUARE FEET OF FLOOR AREA; AND C. HAS MORE THAN 25 PERCENT DUCT SURFACE AREA LOCATED IN ANY UNCONDITIONED SPACE. 22. THE LEAKAGE RATE SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. 9 Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC eroisnva. eun W", a wnwcu rxm� O" lam amr xam�Poia air ane ma aannr, w man rM) 370- M c'wo am-oeN FNc AI " JURISDICTIONAL APPROVAL STAMP Issue Mechanical Permit Set Date 8/09/2019 Sheet Title ABBREVS., LEGEND, NOTES & INDEX Sheet M001 D aaaaaao♦ aaa® 1J PLUMBING FIXTURE SCHEDULE FIXTURE MARK SYMBOL SERVICE CONNECTION FIXTURE DESCRIPTION REMARKS WASTE VENT CW HW GRADE GCO - - - - ADJUSTABLE CLEAN OUT WITH POLYPROPYLENE CLEANOUT PLUG WITH THREADED BRASS INSERT. PROVIDE PVC TO CAST IRON HUB - CLEANOUT BASIS: SIOUX CHIEF 851. FLOOR FCO - - - - ROUND WITH NICKLE BRONZE SCORED FRAMES AND PLATES. BRONZE SCORIATED COVER, VANDAL PROOF. - CLEANOUT BASIS: ZURN Z1400 FLOOR FD-1 2" 2" 3/8" FD-1: GENERAL ROOM FLOOR DRAIN, 6" DIAMETER TYPE B STRAINER, CAST IRON BODY, ADJUSTABLE COLLAR, DRAIN FD-2 - NICKEL BRONZE ADJUSTABLE STRAINER HEAD, TRAP PRIMER CONNECTION. ZURN Z415B NOTE 1 FD-2: SAME AS FD-1 BUT WITH FUNNEL CONNECTION. TRENCH 4" 2" - - HEAVY DUTY DIN 19580 LOAD CLASS C TRENCH DRAIN. RATED AT 56,000LBS - 1,162PSI. 13/16"X 1/2 LONGITUDINAL DRAIN TD-i STAINLES STEEL SLOT BAR GRATE. BASIS: SMITH MFG. 9870-430-SSM NOTE 1 TROUGH 4" 2" - - POLYPROPYLENE TROUGH DRAIN WITH BOTTOM OUTLET AND INTEGRAL LINT FILTER. PROVIDE WITH VENTED, PRIMED P-TRAP DRAIN TD-2 AT SEWER CONNECTION. INSTALL FLUSH WITH FLOOR. 30 GALLON, 4.0 CUBIC FT. CAPACITY. NOTE 1 BASIS: H-M COMPANY COMMERCIAL LAUNDRY EQUIPMENT. AREA AD-1 2" 2" 3/8" - AREA DRAIN, SQUARE TOP, CAST IRON GRATE, CAST IRON BODY WITH BOTTOM OUTLET, SEEPAGE PAN, MEMBRANE FLASHING CLAMP DRAIN AND FRAME, BASIS: ZURN Z609 NOTE 1 HOSE - - 3/4" - HB-1: WALL HYDRANT WITH AUTOMATIC DRAINING AND NON -FREEZE TYPE INTEGRAL BACKFLOW PREVENTER, BRONZE BIB HB-1 - CASING. LEAD FREE. MODEL: ZURN Z1320XL - HOSE - - 3/4" - HB-2: EXPOSED, LEAD FREE, ANTI SIPHON, MODERATE CLIMATE WALL HYDRANT, EXTERNAL VACUUM BREAKER WITH 3/4" HOSE CONNECTION, BIB HB-2 PERMANENTLY FASTENED WHEEL TYPE HANDLER. ZURN Z1341XL OR ACCEPTED EQUAL. - HOSE REEL - - - - HIGH CAPACITY HOSE REEL WITH HEAVY DUTY STEEL CROSS SUPPORT, HOSE: 3/8" ID AND 1/2" OD, 10OFT, RATED AT 300 PSI. AIR HR-A BASIS: COXREEL SLP- 5100, - PROVIDE ADDITIONAL STRUCTURAL SUPPORT AS REQUIRED FOR CEILING AND WALL MOUNTED INSTALLATIONS. HOSE REEL - - 3/4" - HIGH CAPACITY HOSE REEL WITH HEAVY DUTY STEEL CROSS SUPPORT. HOSE: 3/4" ID AND i-1/16" OD, 100FT, RATED AT 300 PSI. WATER HR-W BASIS: COXREEL SLP- 5100. - PROVIDE ADDITIONAL STRUCTURAL SUPPORT AS REQUIRED FOR CEILING AND WALL MOUNTED INSTALLATIONS. WALL 2" 2" 1/2" 1/2" 20GA. KNOCKOUTS IN TOP, BOTTOM, AND SIDES. INSTALL WITH 1/4 TURN BALL VALVES, DRAIN, AND HAMMER BOX WB-1 ARRESTERS. GUY GREY OR ACCEPTED EQUAL. - WALL - - 1/2" - 20GA. KNOCKOUTS IN TOP, BOTTOM, AND SIDES. INSTALL WITH SINGLE 1/4 TURN BALL VALVE AND HAMMER BOX WB-2 ARRESTERS. GUY GREY OR ACCEPTED EQUAL. - WALL - - 1/2" - 20GA. KNOCKOUTS IN TOP, BOTTOM, AND SIDES. INSTALL WITH SINGLE 1/4 TURN BALL VALVE AND HAMMER BOX WB-3 ARRESTERS. GUY GREY OR ACCEPTED EQUAL. - WALL - - 1/2" - 20GA. KNOCKOUTS IN TOP, BOTTOM, AND SIDES. INSTALL WITH SINGLE 1/4 TURN BALL VALVE AND HAMMER BOX WB-4 ARRESTERS. GUY GREY OR ACCEPTED EQUAL. - LAVATORY L -1 1-1/2" 1-1/2" 1/2" 1/2" WALL MOUNTED SINGLE CENTER HOLE LAVATORY, VITREOUS CHINA FOR CONCEALED CARRIER, WITH OVERFLOW. ADA COMPLIANT. BASIS: KOHLER K2053. FAUCET: SINGLE HANDLE, ADA COMPLIANT. DELTA MODERN FAUCET 581-LF-PP. - TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTI -TURN ANGLE STOP W/LOOSE KEY. STAINLES STEEL. BRAIDED FLEXIBLE RISERS. PROVIDE INSTALLED WITH CONCEALED ARM CARRIER AND REMOVABLE DRAIN -STOP, LAVATORY L -2 1-1/2" 1-1/2" 1/2" 1/2" VITREOUS CHINA, WITH OVERFLOW.UNDERMOUNT, RECTANGULAR BASIN. ADA COMPLiANT.NO FAUCET HOLES. KOHLER CAXTON K-20000 FAUCET: SINGLE HANDLE, ADA COMPLIANT. DELTA MODERN FAUCET 581-LF-PP. NOTE 4 TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTI -TURN ANGLE STOP W/LOOSE KEY. SS BRAIDED FLEXIBLE RISERS. BOOT WASH BW-1 - - 3/4" 3/4" CHROME PLATED WASHDOWN STATION WITH 3/4" MIXING VALVE, THERMOMETER, 50' HOSE, REAR TRIGGER SS WATER GUN. BRASS FAUCET THERMOMETER TEE. SS THERMOMETER, 0-200 DEC. F. RANGE. 3/4" INLET SWIVEL HOSE WITH SUPPORT RACK. 10.6 GPM FLOW. - BASIS OF DESIGN: T&s BRASS AND BRONZE WORKS MV-0771-12CW. ROOF DRAIN RD, ORD - - - - COMBINATION ROOF DRAIN AND OVERFLOW ROOF DRAIN WITH LOW DOME. CAST IRON BODY, CAST IRON CLAMP DEVICE, AND OVERFLOW INTEGRAL DOME GUARD, DOME STRAINER, SUMP RECEIVER AND UNDERDECK CLAMP. ZURN Z164 OR EQUAL. - SERVICE SS-1 3" 2" 3/4" 3/4" SERVICE SINK: FLOOR MOUNTED 10" DEEP, ONE-PIECE MOLDED CONSTRUCTION, THERMOPLASTICS BASIN TO SINK INCLUDE INTEGRALLY MOLDED DRAIN ASSEMBLY. SHALL MEET ANSI - SPECIFICAI1ON Z 124-2011. COLOR: WHITE. BASIS: MUSTEE 63M OR ACCEPTED EQUAL. FAUCET: WALL MOUNTED FAUCET WITH VACUUM BREAKER AND BUCKET HOOK. BASIS: CHICAGO 897-CP OR ACCEPTED EQUAL SHOWER SH-1 2" 2" 3/4" 3/4" SHOWER STALL, 63"W X 37-1/2"D X 79-1/2"H, WHITE COLOR. BASIS: COX XS1603CFSAC TRIM: METAL AND BRASS SINGLE -HANDLE HAND HELD SHOWER SYSTEM. CHROME PLATED FINISH. PROVIDE WITH PRESSURE BALANCING CYCLE VALVE, DROP ELL, VACUUM BREAKER, 69 IN. METAL HOSE, MOUNTING - HARDWARE, AND KOHLER AWAKEN 36" SLIDEBAR. FLOW: 1.5 GPM WATERSENSE CERTIFIED. BASIS: K-T78016-4 CP. SHOWER DRAIN: 6" ROUND, CHROME PLATED GRID STRAINER. ZURN 415 OR ACCEPTED EQUAL. SHOWER 711-2 2" 2" 3/4" 3/4" BARRIER -FREE SHOWER STALL, 63"W X 37-1/2"D X 79-1/2"H, WHITE COLOR, BARRIER -FREE SPLASHGUARD BASIS: COX XSi603CFSAC TRIM: METAL AND BRASS SINGLE -HANDLE HAND HELD SHOWER SYSTEM. CHROME PLATED FINISH, PROVIDE WITH NOTE 3 PRESSURE BALANCING CYCLE VALVE, SLIDE BAR, DROP ELL, VACUUM BREAKER, 69 IN. METAL HOSE, MOUNTING HARDWARE AND KOHLER AWAKEN 36" SLIDEBAR. FLOW: 1.5 GPM WATERSENSE CERTIFIED. ADA COMPLIANT BASIS: K-T78016-4 CP. SHOWER SH-3 2" 2" 3/4" 3/4" SHOWER VALVE, HEAD AND WAND: SHOWER AND HAND SHOWER SYSTEM WITH LEVER HANDLES, INTEGRAL SERVICE STOPS AND CHECKS. BARRIER FREE SHOWER STALL BASIS: CDX XS38BFFWAC NOTE 3 THERMOSTATIC MIXING VALVE: LEONARD TEMPERING VALVE, LEAD FREE, ASSE 1070 LISTED. TEMPERATURE AND PRESSURE BALANCED MIXING VALVE WITH ADJUSTABLE SCREW LIMIT HANDLE TURN. SHOWER WAND. DIVERTER CONTROL WITH LEVER HANDLE. IN LINE VACUUM BREAKER, FLEXIBLE METAL HOSE. INSTITUTIONAL SHOWER HEAD, 1.5 GPM MAXIMUM FLOW RATE. LISTED ADA COMPLIANT. PROVIDE VANDAL RESISTANT ESCUTCHEON SCREWS ANCHOR PLATE, ALL INSTALLATION ACCESSORIES, KOHLER AWAKEN 36" SLIDEBAR. ADA COMPLIANT BASIS: K-T78016-4 CP. DRAIN: SAME AS FLOOR DRAIN FD-1. SHOWER SH-4 2" 2" 3/4" 3/4" SHOWER VALVE, HEAD AND WAND: SHOWER AND HAND SHOWER SYSTEM WITH LEVER HANDLES, INTEGRAL SERVICE STOPS AND CHECKS. THERMOSTATIC MIXING VALVE: LEONARD TEMPERING VALVE, LEAD FREE, ASSE 1070 LISTED. TEMPERATURE AND PRESSURE BALANCED MIXING VALVE WITH ADJUSTABLE SCREW LIMIT HANDLE TURN, SHOWER WAND WITH KOHLER AWAKEN 36" SLIDE BAR. DIVERTER CONTROL WITH LEVER HANDLE. IN LINE VACUUM BREAKER, FLEXIBLE METAL HOSE. INSTITUTIONAL SHOWER HEAD, 1.5 GPM - MAXIMUM FLOW RATE. INSTALLATION ACCESSORIES. BASIS: K-T78016-4 CP. DRAIN: SAME AS FLOOR DRAIN FD-1. SINK S-1 2 1-1/2" 1/2" 1/2" 304 SERIES STAINLESS STEEL HAND WASH-UP SINK WITH 7 HIGH BACKSPLASH. FURNISH WITH A WALL HANGER AND SS BRACKETS. BASIS: ELKAY FAUCET: SINGLE HOLE HYTRONIC GOOSENECK SINK FAUCET WITH DUAL BEAM INFRARED SENSOR AND SELF - SUSTAINING POWER SYSTEM. 5-i/4" GOOSENECKSPOUT, DUAL SUPPLY FOR HOT AND COLD WATER SERVICE. 1.0 GPM AERATOR WITH 15 SECOND CYCLE TiME BASIS: CHICAGO FAUCETS 116.934.AB.1 TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTT-TURN ANGLE STOP W/LOOSE KEY. STAINLES STEEL, BRAIDED FLEXIBLE RISERS. SINK S-2 2" 1-1/2" 1/2" 1/2" BAR SINK, STAINLESS STEEL, UNDERMOUNT. 15"X15"X6" DEEP. ADA COMPLIANT. BASIS OF DESIGN: ELKAY ELUHAD121255. PROVIDE WITH FAUCET DELTA TRINSIC 9959-DST. TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, i-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. NOTE 2 SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MUL'n-TURN ANGLE STOP W/LOOSE KEY. STAINLES STEEL. BRAIDED FLEXIBLE RISERS. SINK S-3 2" 1-1/2" 1/2" 1/2" UNDERMOUNT 18 GAUGE 304 STAINLESS STEEL SINK.SINGLE BOWL. PUNCHED FOR SPECIFIED FAUCET. ELKAY ELUH281610PD. INCLUDE LKPD1 PERFECT DRAIN AND STRAINER, AND ALL MOUNTING ACCESSORIES. FAUCET: SINGLE HOLE, SINGLE HANDLE DECK MOUNT. 360 DEG. GOOSENECK SPOUT. NOTE 5 1,8 GPM. CERAMIC CARTRIDGE. DELTA TRINSIC 9159-DST PROVIDE WITH KITCHEN AIR GAP. SINK S-4 2" 1-1/2" 1/2" 1/2" BAR SINK, STAINLESS STEEL, UNDERMOUNT, 23-i/2"X18-1/4"X4-3/8" DEEP. ADA COMPLIANT. BASIS OF DESIGN: ELKAY ELUHAD211545PD. PROVIDE WITH FAUCET DELTA TRINSIC 9959-DST. TRAPS AND TAILPIECES: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P-TRAP AND TAILPIECE. NOTE 2 SUPPLIES: BASSCRAFT OR EQUAL BY MCGUIRE OR EASTMAN, MULTi-TURN ANGLE STOP W/LOOSE KEY. NOTE 5 STAINLES STEEL, BRAIDED FLEXIBLE RISERS. SINK 3-5 3" 2" 1/2" 1/2" CUSTOM, EXTENDED LENGTH AND DEPTH, STAINLESS STEEL SCULLERY TYPE WALL HUNG SINK WITH BACKSPLASH. 14 GAUGE TYPE 304 STAINLESS STEEL, SATiN 5K FINISH. REFER TO DRAWINGS FOR ARRANGEMENT AND DIMENSIONS OF SINK AND TRIM. TRIM: 12" WALL MOUNTED SWING NOZZLE FAUCET WITHI STREAM REGULATOR OUTLET TWO HANDLES. HAND SPRAYER: 1.4 GPM SPRAY VALVE WITH 44" FLEXIBLE STAINLESS STEEL HOSE WITH SPRING AND SPRAY - PROVIDE WITH EYEWASH. FIELD VERIFY LOCATION WITH OWNER. BASIS: HAWS 7360 PROVIDE EYEWASH WITH TEMPERED WATER. TEMPERING VALVE BY LEONARD OR WATTS LOCATED AT SINK. CONTROL: KNEE CONTROL WITH WALL SUPPORT. TRIM AS MANFACTURED BY T AND S BRONZE WORKS. SINK S-6 2" 1-1/2" 1/2" 1/2" STAINLESS STEEL UTILITY SINK, 16 GAUGE, 14" DEEP. 4" BACKSPLASH, ADJUSTABLE BULLET FEET. BOWL: 24" L X 18" W. OVERALL DIMENSIONS: 34" L X 23" W. WITH MATCHED 8" SWING SPOUT DECK MOUNTED FAUCET. - BASKET DRAIN AND INSTALL KIT INCLUDED. BASIS OF DESIGN: GRIFFIN LT.148.228. PLUMBING NOTES AND REMARKS: GENERAL: EXTEND AND CONNECT PIPING TO ALL PLUMBING FIXTURES, FURNISH COMPLETE, FUNCTIONAL SYSTEM. 1. PROVIDE TRAP PRIMERS PIPED TO WATER SUPPLY. 2. PROVIDE WITH INSINKERATOR INDULGE MODERN HOT/COLD FAUCET FHC3300. COORDINATE EXACT LOCATION WITH ARCHITECT. 3. PROVIDE WITH ADDITIONAL KOHLER AWAKEN 24" SLIDE -BAR FOR SHOWER. LOCATE AS SHOWN ON ARCHITECTURAL INTERIOR ELEVATIONS REFER TO SPECIFICATIONS FOR MORE INFORMATION. 4. PROVIDE WITH A LIFT -ANT -TURN STYLE "STOPPER" AT TAIL PIECE, INTEGRAL STOPPER FUNCTION INSTEAD OF TRADINAT10NAL POP-UP. 5. PROVIDE WITH INSINKERATOR GARBAGE DISPOSAL. PLUMBING FIXTURE SCHEDULE (CONT.) FIXTURE MARK SYMBOL SERVICE CONNECTION FIXTURE DESCRIPTION REMARKS WASTE VENT CW HW DRINKING DF-1 1-1/2" 1-1/2" 1/2" - EZH2O DRINKING FOUNTAIN WITH BOTTLE FILLING STATION, WITH GREEN CHILLER, FILTERED, 8 GPH, STAINLESS STEEL FINISH. FOUNTAIN 115V/60HZ, 370W. 1.1 GPM FLOW RATE. 3000 GALLON CAPACITY FILTER WITH BOTTLE SHALL MEET ADA GUIDELINES. BASIS: ELKAY EZH2O LZS8WSLP OR APPROVED EQUAL. - FILLING STATION KOHLER BARDON K-4904-ET, HIGH EFFICIENCY URINAL, VITREOUS CHINA, WHITE, WASHOUT, TOP SPUD, 0.125 GPF, URINAL U-1 2" 2" 1-1/4" - ADA COMPLIANT.FLUSH VALVE: KOHLER K-13520, 0.125 GPF, EXPOSED, 3/4" TOP SPUD. - PROVIDE WITH ACCESSORY FIXTURE HANGERS AND STRAINER ASSEMBLY. WATER WC-1 4" 2" 1-1/4" - WALL -MOUNTED VITREOUS CHINA TOILET, ELONGATED BOWL. 1.6/1.1GPF FLUSH VALVE. (1.27 AVG GPF) CLOSET ADA COMPLIANT KOHLER KINGSTON BOWL K-4325. COORDINATE WITH ARCHITECT FOR COLORS/FINISHES. - FLUSH MECHANISM: DUAL -FLUSH, CHROME PLATED CLOSET FLUSHOMETER SLOAN WES-111 WATER WC-2 4' 2" 1-1/4" - SAME AS WC-1 ABOVE, MOUNTED TO CURRENT ADA ACCESSIBLE STANDARD REQUIREMENTS. CLOSET - COW TONGUE CT-1 - - - - DOWNSPOUT NOZZLE. NOCKEL BRONZE BODY. OPTIONAL THREAD, PVC SLIP-ON, OR NO -HUB INLET. PERIMETER WALL MOUNTED. BASIS OF DESIGN: ZURN 199. - OIL/WATER 4" 2" - - OIL WATER SEPARATOR WITH ADJUSTABLE FRAME COVER. 8 GPM DESIGN FLOW RATE. 2'-0" STATIC WATER DEPTH. SEPARATOR OWS BASIS OF DESIGN OLDCASTLE PRECAST 253-SA-125 - PLUMBING NOTES AND REMARKS: GENERAL: EXTEND AND CONNECT PIPING TO ALL PLUMBING FIXTURES, FURNISH COMPLETE, FUNCTIONAL SYSTEM. 1. PROVIDE TRAP PRIMERS PIPED TO WATER SUPPLY. 2. PROVIDE WITH INSINKERATOR INDULGE MODERN HOT/COLD FAUCET FHC3300. COORDINATE EXACT LOCATION WITH ARCHITECT. 3. PROVIDE WITH ADDITIONAL KOHLER AWAKEN 24" SLIDE -BAR FOR SHOWER. LOCATE AS SHOWN ON ARCHITECTURAL INTERIOR ELEVATIONS REFER TO SPECIFICATIONS FOR MORE INFORMATION. 4. PROVIDE WITH A LIFT -ANT -TURN STYLE "STOPPER" AT TAIL PIECE. INTEGRAL STOPPER FUNCTION INSTEAD OF TRADINA11ONAL POP-UP. 5. PROVIDE WITH INSINKERATOR GARBAGE DISPOSAL. MECHANICAL / ELECTRICAL COORDINATION SCHEDULE ITEM NO. EQUIPMENT DESCRIPTION POWER MOTOR CONTROL EQUIPMENT REMARKS VOLTS PH PROVIDED BY INSTALLED BY WIRE D BY MECH ELEC MECH ELEC MECH ELEC AC SPLIT SYSTEM AC INDOOR 208 1 X X X 2 ODU SPLIT SYSTEM AC OUTDOOR 208 1 X X X 2,6 VRF VRF, IDU ODU 208 3 X X X 2 EF EXHAUST FAN 120 1 X X X 2,7 VEF NEDERMAN SYSTEM 208 3 X X X 2 CF CEILING DESTRAT. FANS 120 1 X X X 2,7 HRV HEAT RECOVERY VENTILATION 208 3 X X X 2,7 FSD FIRE SMOKE DAMPERS 120 1 X X X 2,7 MOD MOTOR OPERATED DAMPERS X X 2,7 DHWH HOT WATER HEATER 120 1 X X X 2 DOMESTIC WATER HEAT TRACING TAPE 120 1 X X X 2 AIR AIR COMPRESSOR 208 3 X X X 2 EUH ELECTRIC UNIT HEATERS 208 1 X X X 2,4 UH GAS HEATERS X X X 2,4 COMPRESSORS DRY SPRINKLER SYSTEM 208 3 X X X 2 FIRE SPRINKLER HEAT TRACING TAPE 120 1 X X X 10 NOTES: -- DISCONNECTS BY ELECTRICAL CONTRACTOR 1. COMBINATION MOTOR STARTER DISCONNECT 2. DISCONNECT SWITCH 3. VARIABLE FREQUENCY DRIVE - VFD 4. LINE VOLTAGE 7-DAY PROGRAMMABLE REMOTE WALL MOUNTED THERMOSTAT 5. DUPLEX PUMPS WITH TWO MOTOR STARTER DISCONNECTS OR ONE STARTER -DISCONNECT WITH ALTERNATOR 6. WEATHERPROOF 7. DISCONNECT AND CONTROL CONTACTOR B. PROVIDE TWO CIRCUITS FOR CONTROL SYSTEM POWER 9, OPERATE FROM WALL SWITCH. 10, PROVIDE CONTROL AND MONITORING FOR HEAT TRACE ON SPRINKLER PIPING FROM FIRE ALARM PANEL 11. PROVIDE STEP DOWN TRANSFORMER TO 24 V 12. LINE VOLTAGE REMOTE WALL MOUNTED THERMOSTAT 13. PROVIDE SMOKE DETECTION SHUTDOWN AND INTERFACE WITH FIRE ALARM PANEL 14, PROVIDE TIMER SWITCH THAT ALTERNATES BETWEEN INTERMITTENT AND MINIMUM VENTILATION RATES 15. PROVIDE GREENHECK VARIGREEN CONSTANT PRESSURE CONTROL PACKAGED SYSTEM AND ALL NECESSARY ACCESSORIES TO CONTROL OFFICE SPACE BUILDING PRESSURE 16. OPERATE FROM LOCKING WALL SWITCH 17.INTERLOCK RETURN FAN TO ASSOCIATED AHU 18. PROVIDE CONTROL COMPONENTS AS REQUIRED TO MEET SEQUENCE OF OPERATION. 19. CONTROL FROM BUILDING TIME CLOCK. DOMESTIC HOT WATER HEATER AND ACCESSORIES MARK REMARKS DHWH-1, DOMESTIC HOT WATER HEATER, NATURAL GAS FIRED, 150,000 BTUH INPUT RATING, 98% THERMAL EFFICIENCY. DHWH-2 100 GALLON STORAGE CAPACITY, MIN. 170 GPH RECOVERY, 100 DEG F RISE. FURNISH HEATER INSTALLED WITH TEMPERATURE AND PRESSURE RELIEF VALVE. PROVIDE WITH GALVANIZED STEEL SEISMIC STRAP BRACING, HOLD -RITE OR EQUAL. PROVIDE FACTORY DIRECT VENT KIT FOR VENTING AND CONDENSATE NEUTRALIZATION KIT. PROVIDE 120V, 1 PHASE. FIELD FABRICATE 4" HOUSE KEEPING PAD. BASIS OF DESIGN: A.O. SMITH CYCLONE MXI BTH 150. DHWCP DOMESTIC HOT WATER CIRC PUMP. 5 GPM, 15 FT HEAD. 1/4 HP 120V 1PH ET BLADDER STYLE EXPANSION TANK, ASME RATED TO 125PSI, 240 F, DRAIN VALVE. BASIS: AMTROL, A.O. SMITH, OR EQUAL. TEMPERING THERMOSTATIC MIXING VALVE. PROVIDE PER ASSE 1070 AT FIXTURE GROUPS AS REQUIRED BY LOCAL AHJ. VALVE SIZED TO MATCH FIXTURE LOAD. BASIS LAWLER, LEONARD, OR BY PRIOR APPROVAL. SUMP PUMP SCHEDULE MARK REMARKS SP-1 CASTIRON SUMP PUMP 1/2 HP MOTOR, 115V, 1PH. UP TO 2.4 AMPS. 1-1/2" DISCHARGE, MAX FLOW RATE OF 61 GPM. BASIS: ZOELLER 163/4163 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 City of Tukwila BUILDING DIVISION Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC BW V�r'DT&16CNF 10 STREET SUITE 1Di SFATaT 'A %18 (206) 3)6-0560 (206) 316-0641 FA% Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL SCHEDULES Sheet M002 LA 04 w Z u 7A w 0 Z Q m a 0 to U V w E- S V 4 VRF INDOOR UNIT SCHEDULE MARK AREA SERVED DESIGN CONDITIONS BASIS OF DESIGN NOMINAL COOLING MBH NOMINAL HEATING CAPACITY MBH NOMINAL TOTAL SUPPLY CFM DESIGN TOTAL SUPPLY CFM AREA OCCUPANTS MIN. OUTSIDE AIR CFM EXTERNAL STATIC IN. W.G. MODEL NUMBER VOLTS/ PHASE ELECTRICAL MCA/MFS WEIGHT LBS. REF LINES REMARKS LIQUID IN GAS IN IDU - 1A BUNK 8 9 20 - 41 320 1 0.0 PKFY-P08NHMU-EW 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.2 BUNK 8 9 20 - 41 320 1 0.0 PKFY-P08NHMU-EW 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.3 BUNK 8 9 20 - 41 320 1 0.0 PKFY-P08NHMU-EW 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.4 BUNK 8 9 320 - 41 320 1 0.0 PKFY-PO8NHMU-EW 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.5 BUNK 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.6 BUNK 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.7 BUNK 8 9 320 - 41Z 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.8 BUNK 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 1.9 COMMON CORRIDOR 12 14 94 - 60 500 NOTE 6 NOTE 6 0.0 PLFY-P12NCMU-E 208/1 .39 MCA 208 VOLT, 15 MOCP 60.0 1/4 1 2" 1,2 IDU - 1.10 COMMON CORRIDOR 12 14 94 - 6oq 500 NOTE 6 NOTE 6 0.0 PLFY-P12NCMU-E 208/1 .39 MCA/208 VOLT, 15 MOCP 60.0 1/4- 1 2" 1,2 IDU - 1.11 MEP 24 27 320 - 88C 600 0 0.4 PEFY-P24NMAU-E 208/1 2.25 MCA 208 VOLT, 15 MOCP 100.0 3 8" 5 8" 1,2 IDU - 1.12 PHYSICAL TRAINING 36 40 812-1165 1000 0 0.4 PEFY-P36NMAU-E 208/1 3.33 MCA 208 VOLT, 15 MOCP 110.0 3 8" 5 8" 1,2 IDU - 2.14 LUNCH 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4- 1 2" 1,2 IDU - 2.1 CPT OFFICE 8 9 320 - 412 320 1 0.0 PKFY-PO8NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 2.2 STATION OFFICE 12. 13.5 265 - 371 340 0 0.4 PEFY-P12NMAU-E3 208/1 1.20 MCA 208 VOLT, 15 MOCP 50.0 3 8" 5 8" 1,2 IDU - 2.3 GREAT RM 36 40 812-1165 1000 0 0.4 PEFY-P36NMAU-E 208/1 3.33 MCA 208 VOLT, 15 MOCP 110.0 3 8" 5 8" 1,2 IDU - 2.4 HALLWAY SOUTH 12 14 94 - 60C 500 NOTE 6 NOTE 6 0.0 PLFY-P12NCMU-E .39 MCA 208 VOLT, 15 MOCP 60.0 1/4" 1 2" 1,2 .IDU-- 25 HALLWAY EAST 4- 9 - 60 500 OT�6 L0 E 6 0O F - 1 MU- _208/1 08 1 .39 MCA 08 VOL 5 OCP 60_0 1 Y 1 2" 2 IDU - 2.6 BACKUP EOC TRAINING - ALTN 24 27 320 - 88 600 0 0.4 PEFY-P24NMAU-E 208/1 2.25 MCA 208 VOLT, 15 MOCP 100.0 3 8" 5 8- 1,2 IDU - 2.7 BC - ALTN 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 2.8 ASST CHIEF 204 - ALTN 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 2.9 ASST CHIEF 203 - ALTN 8 9 320 - 41 320 1 0.0 PKFY-P08NHMU-EW 208/1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 2.10 CHIEF - ALTN 8 9 320- 41 320 1 0.0 PKFY-PO8NHMU-EW 208 1 .34 MCA 208 VOLT, 15 MOCP 40.0 1/4" 1 2" 1,2 IDU - 2.11 ADMIN SUPPORT - ALTN 24 27 320 - 88 600 0 0.4 PEFY-P24NMAU-E 208/1 2.25 MCA 208 VOLT, 15 MOCP 100.0 3 8" 5 8" 1,2 IDU - 2.12 CONF - ALTN 24 27 20 - 88 600 0 0.4 PEFY-P24NMAU-E 208/1 2.25 MCA 208 VOLT, 15 MOCP 100.0 3 8" 5 8" 1,2 - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - SUM 1 340 381.5 1 1 0 0 NOTE: A . EXTERNAL STATIC PRESSURE ALLOWS FOR DUCTWORK AND FILTERS, UNIT MANUFACTURER TO ADD ALLOWANCE FOR WET COIL. B . COIL CONDITIONS: COOLING 80/67 'F EAT DB/WB, 95'F OUTDOOR DB; HEATING: 707 EAT DB, 437 OUTDOOR WB REMARKS: 1. BASIS OF DESIGN: MITSUBISHI MULTI CITY 5. CONSTANT VOLUME FAN COIL 2. PROVIDE WITH ATTACHMENT AND MOUNTING ACCESSORIES COMPLETE. 6. IDU-1.9 AND IDU-1.10 SHARE THE COMMON AREA 3. PROVIDE WITH LONG LIFE FILTER, PLENUM WITH FILTER SLIDE, FACTORY INTERNAL DRAIN PUMP; MERV 8 FILTER. 7. IDU-2.4 AND IDU-2.5 SHARE THE COMMON AREA 4. CONSTANT VOLUME MIXING SECTION 8. NA HEAT RECOVERY VENTILATOR SCHEDULE DESIGN CONDITIONS BASIS OF DESIGN MARK AREA SERVED TOTAL CFM EFFICIENCY, PERCENT, TEMPERATURE MIN. OUTSIDE AIR CFM EXTERNAL STATIC IN. W.G. MODEL NUMBER KW VOLTS/ PHASE CURRENT INPUT, AMPS WEIGHT LBS. REMARKS HRV - 1.1 LEVEL 1 WEST 540 1 70 - .5" LGH-F600 0.7 208/1 3.6 1 300.0 1,2 HRV - 1.2 LEVEL 1 EAST 600 70 - .5" LGH-F600 0.7 208/1 3.6 1 300.0 1,2 HRV - 2.1 LEVEL 2 WEST 600 70 .5" LGH-F600 0.7 208/1 3.6 300.0 1,2 RV - 2.2 LEVEL 2 NORTH - ALTN 300 70 - .5" LGH-F600 0.7 208/1 3.6 300.0 1,2 RV - 2. LEVEL 2 SOUTH - ALTN 600 70 - .5" LGH-F600 0.7 208/1 3.6 300.0 1,2 SUM 2,640.0 0 NOTE: A. AIR TO AIR HEAT RECOVERY VENTILATOR. B. NA REMARKS: 1. BASIS OF DESIGN: LOSSNAY OR ACCEPTED EQUAL. 2. FILTER TYPE: MERV 13 3. NA EXHAUST FAN SCHEDULE SP WEIGHT ELECTRICAL MARK SERVES CFM IN.W.G. LBS SONES WATTS HP VOLTS PHASE REMARKS EF-1 COMMS 300 0.38 30 5.0 0.25 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, ROOM FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK G 085 VG OR ACCEPTED EQUAL. EF-4 EMS DRY/ 500 0.38 75 3.0 250 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, DECON FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK G 080 VG OR ACCEPTED EQUAL. EF-5 EMS 600 0.38 90 4.0 500 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, FACTORY CURB, AND VAR[ -GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK G 090 VG OR ACCEPTED EQUAL. EF-6 SCBA 150 0.38 25 2.5 50 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK G 070 VG OR ACCEPTED EQUAL. EF-7 SHOP 150 0.38 25 2.5 50 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK G 070 VG OR ACCEPTED EQUAL. EF-8 APP BAY 5000 0.50 325 8.1 .75 208 3 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. BASIS OF DESIGN: GREENHECK GB 300 OR ACCEPTED EQUAL. KEF KITCHEN 900 0.50 80 8.0 .33 115 1 DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FAN WITH MOTOR OPERATED DAMPER, HOOD FACTORY CURB, AND VARI-GREEN WITH VARIABLE CONTROL. / RESIDENTIAL BASIS OF DESIGN: GREENHECK G 123 VG OR ACCEPTED EQUAL.t/ GAS UNIT HEATER SCHEDULE MARK ELECTRICAL CAPACITY WEIGHT LBS REMARKS INPUT OUTPUT FLA I VOLT I PHASE MBH MBH UH-1 UH-2 UH-3 UH-4 3.9 115 1 105 87 100 MECHANICALLY INDUCED SEPARATED COMBUSTION, FAN POWERED NATURAL GAS FIRED UNIT HEATER, WITH DIRECT SPARK IGNITION. 409 STAINLESS STEEL HEAT EXCHANGER. VERTICAL DOUBLE WALL COMBUSTION. 83% THERMAL EFFICIENCY. AIR AND VENT TERMINAL KIT WITH ROOF THIMBLE. DIRECTIONAL LOUVERS.HANGER KIT. REZNOR UDAS-100 OR ACCEPTED EQUAL. HEAT PUMP UNIT SCHEDULE EXT. COOLING HEATING STATIC NOMINAL NOMINAL WEIGHT, ELECTRICAL MARK CFM PRES. BTUH BTUH SEER HSPF LBS. MCA MOCP VOLT I PHASE IDESCRIPTION IDU-2.13 0.0" 22,500 26,600 18 8.5 50 1 - 208/ 1 MITSUBISHI MSZ-HE24NA, WALL MOUNTED INDOOR UNIT, WITH REFRIGERANT LINE KIT, INDOOR 230 REMOTE MOUNTED THERMOSTAT. PROVIDE MATCHING OUTDOOR UNIT OR ACCEPTED EQUAL, PROVIDE WITH CONDENSATE PUMP. ODU-3 OUTDOOR - 18 8.5 200 17.1 20 208/ 1 MITSUBISHI MUZ-HE24NA OUTDOOR CONDENSING UNIT OR ACCEPTED EQUAL. 230 CEILING DESTRATIFICATION FAN SCHEDULE ELECTRICAL SIZE WEIGHT MARK REMARKS VOLT PH WATTS DIAMETER LBS CF-1 120/1 100 72 INCHES 40 CEILING SUSPENDED DESTRATIFICATION FAN. CF-2 PROVIDE WITH WALL MOUNTED REMOTE, COMBO CF-3 SPEED AND DIRECTION CONTROL. CF-4 FINISH PER ARCHITECT. OVERALL INSTALLATION HEIGHT PER ARCHITECT. BASIS OF DESIGN: HUNTER HFC 72 VEHICLE EXHAUST EXTRACTION SYSTEM AND ACCESSORIES MARK REMARKS VEF VEHICLE EXHAUST FAN. SWBI, 3600 CFM, 8.0" TOTAL STATIC PRESSURE, 3450 RPM, 7.5 HP, 208V, 3 PHASE. PROVIDE WITH DISCONNECT, VFD AND SILENCER. BASIS OF DESIGN: GREENHECK OR ACCEPTED EQUAL. RAIL NEDERMAN MAGNA RAIL. PROVIDE THREE 6" DROPS, WITH ELECTROMAGNET RELEASE, EACH. 208 VOLT/1 PHASE. REFER TO CONTRACT DRAWINGS FOR REQUIRED LENGTHS AND ARRANGEMENT. BID ALTERNATE 1 BID ALTERNATE BID ALTERNATE GRILLES, REGISTERS AND DIFFUSERS MARK CFM NC LEVEL STATIC PRESSURE CEILING TYPE SIZE BASIS FOR DESIGN NOTES FRAME CONNECTON SD1 30- 50 <20 0.03 ALL 12" X 12" 6" X 6" TITUS MCD AA - 4 WAY THROW 1,2,3 SD2 100-150 <20 0.01 GWB 12" X 12" 6" X 6" TITUS MCD AA - 4 WAY THROW 1,2,3 SD3 150 <20 0.03 LAY -IN 12" X 12" 8" X 8" TITUS MCD AA - 4 WAY THROW 1,2,3 SD4 200 <20 0.03 GWB 12" X 12" 8" X 8" TITUS MCD AA - 4 WAY THROW 1,2,3 SD5 250 <20 0.02 GWB 12" X 12" 10" X 10" TITUS MCD AA - 4 WAY THROW 1,2,3 SD6 50-60 <20 0.03 WALL 8" X 8"' 6" X 6" TITUS 300 RS 1,2,3 SD7 450 <20 0.03 ALL 14" X 14" 12" X 12" TITUS 300 RS 1,2,3 SOB 4500 <20 0.04 GWB 38" X 38" 36" X 36" TITUS 300 RS 1,2,3,4 SD9 50 <20 0.03 LAY -IN 26" X 6" 6 OVAL TITUS MLTZ-39, 2 SLOT MPTZ-39 PLENUM 1,2,3 SD10 100-125 <20 0.04 LAY -IN 50" X 6" 10" OVAL TITUS MLTZ-39, 2 SLOT MPTZ-39 PLENUM 1,2,3 SD11 150-170 <20 0.04 LAY -IN 50" X 6" 10" OVAL TITUS MLTZ-39, 2 SLOT MPTZ-39 PLENUM 1,2,3 SD12 200-250 <20 0.05 LAY -IN 50" X 6" 12" OVAL TITUS MLTZ-40, 2 SLOT MPTZ-40 PLENUM 1,2,3 SD13 165 <20 0.03 NONE 10" DIA 8" DIA TITUS TMRA 1,2,3 SD14 250-300 <20 0.03 NONE 12" DIA 10" DIA TITUS TMRA 1,2,3 SD15 250-300 <20 0.02 DUCT 12" X 12" 10" X 10" TITUS 300 RS 1,2,3 SD16 650 <20 0.02 DUCT 20" X 14" 18" X 12" TITUS 300 RS 1,2,3 SD17 450 <20 0.02 DUCT 16" X 16" 14" X 14" TITUS 300 RS 1,2,3 RG1 200 <20 0.03 GWB 12"X12"" 10" X 10" TITUS 350ZFS 1,2,3 RG2 340-600 <20 0.03 ALL 18"x18" 16" x 16" TITUS 350ZFS 1,2,3 RG3 1000 <20 0.03 DUCT 24" DIA. 22" DIA PRICE RECG 1,2,3,4 RG4 125-150 <20 0.03 LAY -IN 26" X 6" 8" OVAL TITUS MLRTZ-39, 3 SLOT MPTZ-39 PLENUM 1,2,3 RG5 200 <20 0.05 LAY -IN 26" X 6" 8" OVAL TITUS MLRTZ-39, 3 SLOT MPTZ-39 PLENUM 1,2,3 RG6 1000 <20 0.03 GWB 38" X 14" 36" X 12" TITUS 350ZFS 1,2,3,4 RG7 50 <20 0.05 LAY -IN 26" X 6" 8" OVAL TITUS MLRTZ-39, 2 SLOT MPTZ-39 PLENUM 1,2,3 RG8 600 <20 0.05 LAY -IN 74" X 6" 8" OVAL TITUS MLRTZ-39, 3 SLOT MPTZ-39 PLENUM 1,2,3 EG1 30-100 <20 0.034 ALL 10" X 10" 81' X B. TITUS 350ZFS 1,2,3 EG2 100-200 <20 0.02 ALL 12" X 12" 10" X 10" TITUS 350ZFS 1,2,3 EG4 250-300 <20 0.02 ALL 14" X 12" 12" X 10" TITUS 350ZFS 1,2,3 EG5 300 <20 0.034 WALL 18" X 10" 16" X 8" TITUS 350ZFS 1,2,3 EG6 800 <20 0.02 DUCT 20" X 16" 18" X 14" TITUS 350ZFS 1,2,3 EG7 300-350 <20 0.02 DUCT 20" X 12" 18" X 10" TITUS 350ZFS 1,2,3 EG8 4500 <20 0.034 GWB 42" X 42" 40" X 40" TITUS 350ZFS 1,2,3,4 EG9 50 <20 0.02 LAY -IN 26" X 6" 6" OVAL TITUS MLR-39, 2 SLOT/MP-39 PLENUM 1,2,3 EG10 50 - 75 <20 0.02 LAY -IN 26" X 6" 6" OVAL TITUS MLR-39, 2 SLOT/MP-39 PLENUM 1,2,3 EG11 100-150 <20 0.03 LAY -IN 26" X 6" 8" OVAL TITUS MLRTZ-39, 3 SLOT MPTZ-39 PLENUM 1,2,3 TG1 150 <20 0.01 GWB 16" X 8" 14" X 6" TITUS 350 RS 1,2,3 TG2 150 <20 0.02 GWB 16 X 8" 14" X 6" TITUS 300 RS 1,,3 22 TG3 150 <20 0.02 DOOR 20" X 16" 18" X 14" TITUS T700S ill: NOTES: 1. DUCT CONNECTION TO DIFFUSER OR GRILLE SHALL BE MINIMUM NECK SIZE. 2. PROVIDE SMOOTH, GRADUAL SHEETMETAL FITTING TRANSITION FROM DUCT TO GRILLE, REGISTER OR DIFFUSER. 3. REFER TO ARCHITECTURAL PLANS (FLOOR, CEILING AND ELEVATIONS) TO DETERMINE FRAME TYPE AND LOCATION. 4. PROVIDE ADDITIONAL STRUCTURAL SUPPORT FOR OVERSIZE AIR TERMINAL AS REQUIRED. ROOF VENTILATOR SCHEDULE PRESSURE THROAT WEIGHT, MARK CFM DROP DIMENSIONS LBS. REMARKS RV-1 4500 0.05 36" X 36" 160 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGI RV-2 1200 0.05 30" X 22" 40 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGI/FGR PROVIDE WITH DUCT HEATER. BASIS: GREENHECK IDHB RV-3 600 0.05 14" X 14" 50 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER RV-4 INTERLOCKED TO ASSOCIATED FAN OPERATION. RV-5 BASIS: GREENHECK FGI/FGR RV-6 RV-7 RV-8 RV-9 300 0.05 12" X 12" 40 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER RV-10 INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGI/FGR RV-13 900 0.05 16" X 16" 55 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGI RV-9 300 0.05 12" X 12" 40 ROOF VENTILATOR WITH CURB, MOTOR OPERATED DAMPER RV-10 INTERLOCKED TO ASSOCIATED FAN OPERATION. BASIS: GREENHECK FGI/FGR RV-11 600 0.05 14" X 14" 50 RV-12 1- - - - - - - - - - - - - - - - - - - - - - - - - - - - ......... _. NATURAL GAS FIRED APPLIANCE CAPACITY SCHEDULE INPUT CAPACITY MARK ITEM BTU,/HR. CF/HR REMARKS DHWH-1 WATER HEATER 150,000 146 24/7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR DHWH-2 WATER HEATER 150,000 146 24/7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR UH-1 APP BAY UNIT HEATER 200,000 195 24/7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR UH-2 APP BAY UNIT HEATER 200,000 195 24/7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR UH-3 APP BAY UNIT HEATER 200,000 195 24/7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR UH-4 APP BAY UNIT HEATER 200,000 195 24/7 OPERATION, PROVIDE 2 PSI TO 6-14" REGULATOR RANGE KITCHEN RANGE 50,000 49 PROVIDE 2 PSI TO 6-14" REGULATOR BAR B QUE OUTDOOR BAR B QUE 100,000 97 PROVIDE 2 PSI TO 6-14" REGULATOR REVIEWED FOR SUBTOTAL 1,250,000 1,217 CODE COMPLIANCE APPROVED FACTOR OF SAFETY (25%) 312,500 304 SUM 1,562,500 1,521 City of Tukwila AIR COMPRESSOR SCHEDULEDIVISION MARK VOLTS/CYCLES PHASE MOTOR HP MAX PSIG ACFM REMARKS COMP-1 208/60/3 5 175 14 80 GALLON VERTICAL TANK MOUNTED MOTOR AND COMPRESSOR. BELT DRIVE RECIPROCATING COMPRESSOR. PROVIDE INSTALLED WITH VIBRATION ISOLATION, FILTER MOISTURE TRAP AND PRESSURE REGULATOR. BASIS FOR DESIGN: INGERSOLL RAND 2475-N5 COMP-2 208/60/1 2 - - DRY RISER COMPRESSOR BY FIRE SPRINKLER. DESIGN BUILD CONTRACTOR. LOCATED IN MECHANICAL ROOM. BASIS FOR DESIGN: GAST BID ALTERNATE L VRF OUTDOOR UNIT SCHEDULE MARK REMARKS OUTDOOR AIR COOLED OUTDOOR UNIT. 240 MBH NOMINAL COOLING CAPACITY, 95' DB ENTERING AIR, 80'/67'F DB/WB UNIT INDOOR, 270 MBH NOMINAL HEATING CAPACITY, 43' WB ENTERING AIR, 70 DEGREE DB INDOOR. 42 MCA (EACH OF 2 MODULES), 208/230 VOLT, 3 PHASE ODU-1 INVERTER DRIVEN SCROLL COMPRESSOR, R410A REFRIGERANT, 11.7 EER, 18 IEER, 3.41 COP 1000 POUNDS NET WEIGHT. MITSUBISHI CITY MULTI PURY-P240TSLMU-A. - - PROVIDE WITH TWINING KIT, JOINT KIT, LOW AMBIENT, SNOW/HAIL GUARDS AND BASE PAN HEATER. - - - - - - - - - - - - - - - - - - - - - AIR COOLED OUTDOOR UNIT. 96 MBH NOMINAL COOLING CAPACITY, 95' DB ENTERING AIR, 80'/67'F DB/WB INDOOR. 108 MBH NOMINAL HEATING CAPACITY, 43' WB ENTERING AIR, 70 DEGREE DB INDOOR. 42 MCA (EACH OF 2 MODULES), 208/230 VOLT, 3 PHASE ODU-2 INVERTER DRIVEN SCROLL COMPRESSOR, R410A REFRIGERANT, 11.7 EER, 18 IEER, 3.41 COP 500 POUNDS NET WEIGHT. MITSUBISHI CITY MULTI PURY-P96TLMU-A. PROVIDE WITH TWINING KIT, JOINT KIT, LOW AMBIENT, SNOW/HAIL GUARDS AND BASE PAN HEATER. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENEUSCH GROUP, INC teW Nlp 569 SIRFET SUfIE.t S318-0WA e�8M (206) 378-0669 (ZOB) S16-0041 FAJ( 20 2019 I -CENTER Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL SCHEDULES Sheet M003 p OUTSIDE AIR HEAT RECOVERY VENTILATION UNIT, RHRV SECTION REMARKS SUPPLY FAN FAN WALL, PLUG AIRFOIL FAN. FAN 18" WHEEL DIAMETER, 3500 RPM MAXIMUM SECTION DIRECT DRIVE, 2.3 HP, 208 VOLT, 3 PHASE. 1900 CFM, 3" STATIC PRESSURE, WITH VFD. EXHAUST FAN FAN WALL, PLUG AIRFOIL FAN. FAN 18" WHEEL DIAMETER, 3500 RPM MAXIMUM SECTION DIRECT DRIVE, 2.3 HP, 208 VOLT, 3 PHASE. 1400 CFM, 3" STATIC PRESSURE, WITH VFD. ELECTRICAL FACTORY MOUNTED STARTERS AND DISCONNECTS. SINGLE POINT POWER CONNECTION. 208 VOLT, 3 PHASE, 185 MCA, 200 MOCP HEATPUMP TOTAL COOLING CAPACITY 77 MBH, SENSIBLE CAPACITY 65 MBH, DX COIL, R410A SECTION REFRIGERANT, TOTAL HEATING CAPACITY 60 MBH, 12.2 EER. PROVIDE COMPRESSOR NOISE WRAP BLANKET. PROVIDE ECM CONDENSER FAN MOTORS WITH VARIABLE SPEED CONTROL. BACKUP ELECTRIC RESISTANCE BACKUP HEATING SECTION. 30 KW, 6 STAGE, SCR CONTROL. HEATING SECTION HRV ENERGY WHEEL RECOVERY. 208 VOLT, 3 PHASE. SENSIBLE EFFICIENCY OF 82%. INCLUDE BYPASS DAMPERS & RECIRCULATION DAMPER FOR ECONOMIZER OPERATION ISOLATION FAN AND MOTOR RESILIENTLY ISOLATED FROM THE FAN CABINET. DAMPER PROVIDE EXHAUST HOOD WITH BIRD SCREEN. PROVIDE BYPASS SECTION TO FURNISH SECTION ECONOMIZER COOLING WHEN HEAT RECOVERY IS NOT REQUIRED. THE OUTDOOR AIR SUPPLY AND THE EXHAUST OUTLET SHALL BE PROVIDED WITH CLASS 1A MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEMS OR SPACES ARE NOT IN USE OR DURING UNOCCUPIED PERIODS PER SEC C403.2.4.3. FILTERS 2" PLEATED, MERV 8. 0,54" FILTER PRESSURE DROP FOR CA AND RA PRIOR TO WHEEL CABINET PERFORATED GALVANIZED SHEETMETAL INNER LINER IN FAN SECTIONS, SOLID OUTER PANEL 2" THICK, 3 POUND DENSITY ACOUSTICAL INSULATION. MINIMUM OF 6" BASE RAIL FINISH IN STANDARD FACTORY ENAMEL, WEIGHT 3000 POUNDS, VERIFY WITH MANUFACTURER ACCESSORIES 14" INSULATED CURB AND ALL MOUNTING ACCESSORIES. ACCESS ALL ACCESS FROM SIDE OF UNIT. REFER TO MECHANICAL DRAWINGS. INSTALLATION REFER TO MANUFACTURERS WRITTEN INSTRUCTIONS AND CONTRACT DOCUMENTS. SMOKE NOT REQUIRED. DETECTION MANUFACTURER BASIS FOR DESIGN: DAIKIN, ALTERNATES AS ACCEPTED BY PRIOR APPROVAL. BRANCH CIRCUIT CONTROLLER SCHEDULE MARK REMARKS MAIN BRANCH BRANCH CIRCUIT CONTROLLER. CONTROLLER 1.63 MCA, 208/230 VOLT, 1 PHASE. R410A REFRIGERANT, 16 PORTS, 162 POUNDS. BC-1.1 MITSUBISHI CITY MULTI: CMB-P1016NU-GA. SUBBRANCH SUB BRANCH CIRCUIT CONTROLLER. CONTROLLER 0.64 MCA, 208/230 VOLT, 1 PHASE. R410A REGRIGERANT, 8 PORTS, 82 POUNDS. BC-1.2 MITSUBISHI CITY MULTI: CMB-P108NU-GB. MAIN BRANCH BRANCH CIRCUIT CONTROLLER. CONTROLLER 1.63 MCA, 208/230 VOLT, 1 PHASE. R410A REFRIGERANT, 16 PORTS, 162 POUNDS. BC-2 MITSUBISHI CITY MULTI: CMB-P1016NU-GA. ELECTRIC UNIT HEATER SCHEDULE SERVES ELECTRICAL DATA MARK WATTS I VOLTS I PHASE ACCESSORIES EUH-1 DECON 4000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KAWH EUH-2 EMS 3000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF - DRY CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KAWH EUH-3 EMS 3000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KAWH EUH-4 EMS 3000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KAWH EUH-5 SCBA 2000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KAWH EUH-6 SHOP 3000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF- CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KAWH EUH-7 GEAR 2000 208 1 SUSPENDED ELECTRIC UNIT HEATER, CONTROLLED BY SELF - WASH CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KBP EUH-8 GEAR 2000 208 1 SUSPENDED ELECTRIC UNIT HEATER. CONTROLLED BY SELF - STORAGE CONTAINED THERMOSTAT. PROVIDE WITH ALL MOUNTING ACCESSORIES. BASIS OF DESIGN: KING KBP BID ALTERNATE VFD SCHEDULE VFD TAG SERVICING MOTOR DATA ENCLOSURE RATING DISCONNECT BYPASS COMMUNICATIONS BASIS OF DESIGN NOTES QTY VOLTAGE I HP EA VFD-1 RHRV 1 208 2.3 NEMA 3R YES YES BACNET MSTP 1 ABB VFD-2 VEF 1 208 7.5 NEMA 3R YES YES BACNET MSTP ABB NOTES: 1. AT MINIMUM, VFD SHALL INCLUDE 5% IMPEDANCE VIA 5% AC LINE REACTOR OR DUAL DC BUS CHOKES SIZED TO 5% EQUIVALENT IMPEDANCE. REACTORS OR CHOKES SHALL BE SWINGING DESIGN. 2. PROVIDE UL1449 TYPE 2 SURGE SUPPRESSION DEVICE. 3. VFD SHALL INCLUDE ALPHA -NUMERIC KEYPAD INTERFACE, WITH DISPLAY IN PLAIN ENGLISH (DISPLAY RELYING SOLELY ON CODES ARE NOT ACCEPTABLE). REVIEWED FOR CODE COMPLIANCE APPROVED ' SEP 10 2019 City of Tukwila BUILDING DIVISION nECEIVEi� CITY OF T UKWILA AUG 20 2019 PERMIT CENTER Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC e.DDumcu. umro LADED & MEDWWICPL ENOIN6RINC (20) 3 -58 SIPE£T SDB (Al SM- WA 9 FM (208) 378-0589 (20fi) 3]e-0841 FA% Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL SCHEDULES Sheet M004 @1 F p SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROMDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE CCMPUANT INSTALLATION. A B,1 C C,1 C, S — F,1 I I I I I I i I I I I I I I I I I I I I I I I 3"W UP TO S=5 I I I I I I ---------------------------------------------------- ------------------- -------- ------ -- - -- - - -- - --- -- --- /77 / ---- - - - - - - - - - 2"V UP I I_ I I I I � 47W UP TO FCO I I I 4,,W 4„W I I r— -----I— — — ——!7F — — — —— --------------------— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ------------------------1-------------------� ——r--------------------------------------------------------------- -----------------------------------------4 — "W UP O D-1 � I I 1 I I I I JUP TO AC I I I I I I I i 2"W UP TO S=6 I I I I ----- --- -I I � r----- ---- 4^SUP ' _ � I I TYP 2 / � - - - - - --- F--- _--- -----_1______________— _ ___ _______________ --_____rJ - - - �../ -r- --- ----- - -- - I �I 6a 6.9 —�- - - - - - --------- -�-�- - - - -- -- - -�- - --, �a -- -- n�- - -i I I I (I II I I I II II i I I I I I I I II 4"OW UPI TO TD=1 1 I 1 I I I I ( 4"OW UP TO TD-1 I 3 O I II El a I I i I I I I I 11 II I El I I (I I I I I i I II I I I II I I I II i I 4"OW UF TO -1 4"OW UP TO TD=1 I I J L_ _ I I -- I I 6"OW UP TO FQQ L B it 5 - - - - - - - - - - - - - - -I - - - I - - - - I I I I I I - - J 6„OW _ _ - - 6"OW 4"OW UTOFOO 4"OW U TO TD=1 I I ---------------------------'i I I I I I I I I I I I I I I I i I I MATCH IUD SEE 1yM2017 I • J 1 •Ma , 12WIRMIL61.31 I I I I I I I I I I I I I I I I I I ------------ ------------ ___________, I I I I i i I I I I I I I I I I I I I i I I I I I I I _I_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I r-------- ---------r----T F- ------------------13WUPTOFCO IF -- -- — — — — — .4„W UP TO F SCALE: 1/4" = 1'-0" 141 NORTH I I I I I I I I i I I I I I I � I I I I 470W UP TO 1D=1 I I I 4"OW UP TO FCO I I I I I i I El l I I 6"W UP TO GCO TYP 2 2"V ON, TYP 2 1 I I MATa-I UNE _ SEE 1/M201S rl 3'WUE� TO SS-tr---------------I----------------- I I I � 4"W UP TO COO 4'W POO TO SITE SANITARY, SEE CIML (TO DFU) 6"W POC TO SITE SANITARY, SEE CIVIL (120 DFU) - CIL WATER SEPARATOR, SEE @ M9Ot SEAL+ QAT,= PEoRt,)r,,,zr APES nECEIVED CITY OF ii11.'.tiILA AUG 2 0 2019 Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC ACOlASNCN. AV010 / NOEO k MECHPNICAL ENGINEERING 1999 WEST NIGfER50N 5tREET SUITE 2'It SFpifLE WA 98f 19 (205) 3J8-O588 (208) ]J8-0&fl FAX Issue Mechanical Permit Set Date 8109/2019' Sheet Title MECHANICAL FOUNDATION PLAN NORTH Sheet M20 1 N tA ry UJ Z v (n LIJ Z Q m Ile (n v U I FLAG NOTES: ----------------- ---- - - - - -i l----- - - - - -- - I - ------ ---- t----- - - - - - - I i i I I I I I I 1 I 1 �--- ---z 1 I I MATCHIUNE - — I SEE 1/M201N 2"V-U r-- -- - - ----- -- - - -- --- -- -- -----------------�3"WUPTOFCO F -- -- I 1 I" I - -- ,4WUPTOF I 4'W UP TO FCO "W UP TO FCO fW UP TO BW 1 i 4'W UP TO BW-1 UP TO FD 1 "V UP - 1 L I -- -L-- ---- -- -_ -------� I ------- - - - - -- � "V UP 2"W P TO S-1 2"VUP � — �`W UP TO -1 2"W UP TO S=1 / "W UP TO 1 2"W UP TO S-1 - - WUPTOL_1 2"V UP "V UP I i ❑ n p"W UP TO TD=2 "V UP ZIN UP TO FD-1 r--"-----J I, -- - ---- - - --- � I , I III 4"W UP TO I I I I I tee; I 1 I , I r- - - - - - - I I -- _ - 2„W U1, 10 FD=1--=------ `_- --� -- _-------_� _ MATCH UNE SEE 1/M201N 3'WU TOSS=1r--------------- --------------- 1 I I I I I I I 1 I I I I I I I I I I I -- - - - - - - - ----- - - - - -I I I ( I I I I I I I I I I I I I I I I I I I I I - I SIEEVE FOUNDATION WALL PIPE PENETRATIONS, TYPICAL REFER TO DEFAL0 IN XXX STRUCTURAL DRAWNGS. COORDINATE PENETRATIONS WTH FOUNDATION PLAN ON MEET S)A I II I 6"W 6„W I i I I I 2"W UP II ❑ W 33 SS-1 UP 0 "" 3"W UP TO -2 °W - - 1 UUP TO DF-1 - - - - - III 1 - - - - - - - - 3„W 4P i 2"W UP- - - - - - - 'V P 2' UP ; V TO W9 1 i 2"VIUP TO FD=1 2„N� W UP TO -2X-11 3"W PTO -1 T-- - - 2'WU' TO EU-1 6"W POC TO SITE SANITARY, - - -- - - - - -,--------- -- - - - - - -- SEE CIML (114.5 DFU) - -- 3 W UP TO I 11 4„W - 14W-UP-T&I CO- - - I i - —�• - - - TO GOO 6 2 W 4"W UP TO W4Ti I - - - - ' I 4"W UP 4''W UP TO �hC-1SEE 9 6"W III 1 --- _-_______J 2"W UP TO FD-1 J i I I I 2" W UP I p r 4'W UP TO POD -J I I I I 4W t-- `-- - - I -I I - ----- -� ---' -------- i i i I I I 1 I I I I 3"W UP TO 9i=1 2"fit UP TO FDFD=1 I I 1 I I II i 1 I I II I 1 ❑ I I I I 1 2"W UP TO (2) L_2 I I 2"W UP To M-11 -- 2"W TO FD=1- ❑ I 1 - - - - - - - - - - - - - -- '4"WUPTOFCO - - - - - - - - - - I I I I I I 2"W UP TO (2) L_2 I I I I I I I 2"V UP I I 1 I I I 1 I I i I I I I I I I I I I I 4"W UP I 1 i f- I I 2"V UP�\ C�--- L I i 1 1 ----- - - - - ----------------------`_=- JL-- - - - - -, I I I I I i I i I i I I 1 I I I I I I I I I I I ( I I - - - 2"W UP TO F I 4"W UP TO Fd0 J_ _—_ _ _ _ -_ _ I I I ___ _— __ 4"RWL UP I I GA UP TO METER �___________ ___________J ( 1-------------------___J I I I I I 9RWL DN TO (E)STORM I I I I I I I A B C C1 D E I MECHANICAL FOUNDATION PLAN SOUTH SCALE: 1/4" = 1'-0" NORTH 7'W UP TO FD=2 4"W UP TO STANDPIPE DRAIN 21/2"CW UP X'F TO FDC X'F UP TO ARE SPRINKLER RSR POO TO SITE DOMESTIC WATER, SEE CIM POO TO FDC, SEE CIVIL POO TO SITE FIRE SERVICE, SEE CIVIL POO TO SITE GAS, SEE CIML (r--- -= .VICE •a SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROMDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE CCMPUANT INSTAUATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG I THE GREENBUSCH GROUP, INC I MAOSNCo-L, NA010 N Y10E0 b MECNMI- ENGIN 1119 190G) 3 a-05GGN STREET SUiIE 2G1 5378- 64 9 FM (208) S]b-0569 (208) 3]b-084f FN( Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL FOUNDATION PLAN SOUTH Sheet M201 S N I Vr c NI a 0) (n H N 0 iv w U) 2E Cn ro 2 m ai ii a cv, Ef> 0 z co FIRE SPRINKLER NOTES 1. THESE DRAWINGS ARE DIAGRAMMATIC REPRESENTING THE INTENT OF THE WORK. REFER TO THE SPECIFICATIONS FOR COMPLETE SYSTEM REQUIREMENTS. 2. PROVIDE ALL DESIGN, MATERIAL, LABOR, SUPERVISION, TOOLS, AND ITEMS NECESSARY, FOR THE CONSTRUCTION, INSTALLATION, CONNECTION, START—UP, TESTING AND OPERATION OF ALL FIRE SUPPRESSION WORK FOR THIS PROJECT. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO DESIGN AND INSTALL A COMPLETE WORKING SYSTEM MEETING ALL CODES. 3. THE INTENT OF THESE DRAWINGS IS TO DIAGRAMMATICALLY SHOW THE FIRE SPRINKLER PIPING AND ARRANGEMENT OF HEADS IN OCCUPIED AND CRITICAL AREAS ONLY. SPRINKLER HEADS PROTECTING ATTICS, CONCEALED AREAS AND PLENUMS ARE NOT INDICATED BUT REQUIRED.THE DRAWINGS DO NOT NECESSARILY REFLECT THE FULL EXTENT OF PIPE OR SYSTEM COMPONENTS REQUIRED OR EXPECTED. THE FIRE SPRINKLER CONTRACTOR IS NOT RELIEVED FROM INCLUDING ALL REQUIRED COMPONENTS AND WORK IN THEIR CONTRACT. 4. PROVIDE SPRINKLER HEADS, PIPING, HEADERS, VALVES, ALARMS AND ACCESSORIES AS REQUIRED FOR A COMPLETE, FUNCTIONAL, CODE COMPLIANT SYSTEM. PIPE SIZING SHOWN IS AN ESTIMATE, FINAL PIPE SIZE SHALL BE COMPLETED BY THE CONTRACTOR AND INCLUDED IN THE PERMIT SUBMITTAL. CONSTRUCTION SHALL NOT BEGIN UNTIL THE CONTRACTOR'S SHOP DRAWINGS ARE APPROVED BY THE LOCAL JURISDICTION AND SHOP DRAWINGS HAVE BEEN REVIEWED BY THE PROJECT ARCHITECT. 5. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE ADDITIONAL HEADS, PIPING, VALVES AND APPURTENANCES TO ENSURE ADEQUATE COVERAGE IN ALL SPACES INCLUDING ABOVE CEILINGS, IN CRAWLSPACES AND IN ATTICS. 6. THE AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 (IBC 903.31 STANDARDS), IBC, IFC AND ALL LOCAL CODES AS A MINIMUM STANDARD. ADDITIONAL REQUIREMENTS WILL BE NOTED IN THE SPECIFICATIONS OR IN THESE DRAWINGS THAT EXCEED CODE REQUIREMENTS. 7. PROVIDE COVERAGE FOR THE ENTIRE FACILITY INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC SPACES, CATWALKS, INTERSTITIAL SPACES, OVERHANGS AND MECHANICAL/ELECTRICAL ROOMS TO ACCOMPANY THE AHJ CODE REQUIREMENTS. THE ASSUMPTION OF FIRE ALARM DEVICES OR SYSTEMS BEING INSTALLED DOES NOT RELIEVE THE FIRE SPRINKLER CONTRACTOR OF PROVIDING COMPLETE COVERAGE OF ALL AREAS. 8. FIRE SPRINKLER MAIN NOT SHOWN SHALL BE LAID OUT PER CODE SPECIFIED AND SYSTEM REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR AREAS NOT SHOWN OR FOR MULTIPLE FLOORS THAT REQUIRE FIRE SPRINKLING COVERAGE. 9. ALL PIPING SHALL BE CONCEALED IN FINISHED AREAS TO THE GREATEST EXTENT POSSIBLE. ANY EXPOSED PIPING IN UNFINISHED AREAS SHALL BE ONLY BY APPROVAL OF THE ARCHITECT AND BE PAINTED TO MATCH SURROUNDINGS. IN VAULTED CEILING AREAS, PIPING SHALL BE INSTALLED IN SOFFIT OR BEHIND CEILING FINISH. 10. SEE ARCHITECTURAL DRAWINGS FOR ATTIC AND CONCEALED SPACES, PROVIDE SPRINKLER COVERAGE IN THOSE SPACES AS APPLICABLE. 11, PROVIDE PREACTION FIRE SPRINKLER COVERAGE IN COMM ROOM. 12. EXPOSED FIRE SPRINKLER PIPING SHALL BE LIMITED TO THE AREAS SHOWN. ANY DEVIATIONS IN THE FIRE MAIN LAYOUT SHOWN HERE SHALL BE APPROVED BY THE ARCHITECT BEFORE INSTALLATION AND SHALL BE AT NO ADDITIONAL COST TO THE OWNER. NO EXPOSED PIPING WILL BE ALLOWED IF, IN THE BUILDING STRUCTURE, THE ARCHITECT HAS PROVIDED SHAFTS, FURRED AREAS OR CONCEALED SPACES WHERE PIPING COULD BE HIDDEN FROM VIEW. DO NOT RUN PIPING OVER ELECTRICAL PANELS OR SWITCHGEAR EXCEPT WHERE LOCATED ABOVE THE STRUCTURAL CEILING. 13. CENTER SPRINKLER HEADS AND OTHER EXPOSED SPRINKLER SYSTEM ACCESSORIES IN CEILING GRIDS ON CENTERLINES OF ARCHITECTURAL FEATURES. REFER TO ARCHITECTURAL. 14. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF THE PIPING AND HEADS TO AVOID INTERFERENCE WITH LIGHT FIXTURES, ELECTRICAL CABLE TRAYS, HEATING/COOLING EQUIPMENT, DUCTWORK AND ANY ARCHITECTURAL FEATURES SUCH AS SKYLIGHTS, STAIRWAYS, ETC. IN CATWALK AREAS, PIPING SHOULD BE RUN AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM HEADROOM OVER THE MECHANICAL EQUIPMENT AND AISLE SPACES. MAXIMUM CLEARANCE SHALL BE MAINTAINED FOR SERVICE ACCESS AND MAINTENANCE FOR ALL EQUIPMENT. FAILURE TO COORDINATE SHALL BE JUSTIFICATION TO REQUIRE THE CONTRACTOR, AT HIS OWN EXPENSE, TO MOVE AND REDO HIS WORK. 15. ALL PIPING SHALL BE SLOPED PARALLEL TO BUILDING STRUCTURE AND INSTALLED TO DRAIN. 16. PROVIDE THRUST BLOCKS AT ALL CHANGES IN DIRECTION FOR UNDERGROUND SERVICE PIPING. 17. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE, RECESSED HEADS WHERE EXPOSED IN CEILINGS. 18. PROVIDE DRY PIPE FIRE SPRINKLER COVERAGE FOR ALL EAVES AND OVERHANGS THAT EXTEND BEYOND 4' FROM THE BUILDING, COVERED WALKWAYS/ENTRYWAYS AND ANY UNCONDITIONED AREAS AND SPACES. 19. PROVIDE HEAD GUARDS OR WIRE PROTECTIVE CAGES AS REQUIRED ON ALL SPRINKLER HEADS THAT MAY BE SUBJECT TO DAMAGE BY INCIDENTAL CONTACT. FIRE SPRINKLER LEGEND: /QN WET UPRIGHT SPRINKLER HEAD OWET PENDANT SPRINKLER HEAD WET UPRIGHT ABOVE PENDANT DRY UPRIGHT SPRINKLER HEAD OHIGH TEMPERATURE SPRINKLER HEAD FIRE PROTECTION WATER p DRY SIDEWALL SPRINKLER HEAD OBUILDING WALL U z N TO BUILDING FIRE SPRINKLER SYSTEM z 00 ;1 u, TO FIRE SPRINKLER SYSTEM 0 in OO O O I 24 INCHy O O ` O O • � �[rl� ]SiZy t[�Zi3�X� PERIMETERS OF MINIMUM CLEARANCES TO BE PAINTED ON FLOOR IN WHITE ENAMEL PAINT STRIPE, WITH 2 INCH STENCILED BLACK LETTERS TO SAY: "DO NOT BLOCK ACCESS" DOUBLE DETECTOR CHECK VALVE SCHEMATIC SCALE: NONE DETAIL NOTES: ���4 1. RISER DIAGRAM IS DIAGRAMMATIC AND DOES NOT RELIEVE ALARM GONG OR WAIVE ANY IFC, NFPA, OR LOCAL REQUIREMENTS TEST DRAIN, TYP — DRAIN TO EXTERIOR OR STANDPIPE, TYP WET PIPE VALVE FLOW SWITCH, T F )OUBLE DETECTOR ( HECK BACKFLOW w ASSEMBLY FIRE SPRINKLER RISER DIAGRAM SCALE: NONE ZO 18" LONG SPOOL (FL x PE) 30 FLANGE COUPLING ADAPTOR ® APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA SO O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L & I © METERED 3/4 INCH BY—PASS DCVA — BY—PASS METER SHALL BE A 3/4 INCH 'METERED SR POSITIVE DISPLACEMENT METER. 07 WALL MOUNTED FIRE DEPARTMENT CONNECTION. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY—PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER, TEST REPORT MUST BE SUBMITTED TO LOCAL AUTHORITY'S WATER UTILITY ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE. INSTALL BRASS PLUGS AT ALL TEST COCKS. WET PIPE SYSTEM (TYP) DRY PIPE SYSTEM (TYP) TO FIRE ALARM PANEL, TYP TEST DRAIN, TYP DRY PIPE VALVE AIR COMPRESSOR, PROVIDE WITH 4" HOUSEKEEPING PAD Y tiZdil n �a � F�Y►T:1 RELEASE PANEL PREACTION VALVE DETAIL NOTES: DDCVA MUST BE INSTALLED IMMEDIATELY AFTER PIPE PENETRATION THROUGH BUILDING FLOOR SLAB ROOM IN WHICH DDCVA IS LOCATED SHALL: A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. B. HAVE A HEATING SYSTEM (40' F MIN. TEMP.) NO HEAT TAPE C. NOT BE USED FOR STORAGE AROUND THE DDCVA D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIV. A RIGHT —OF —ENTRY AGREEMENT MUST BE GRANTED TO THE LOCAL AUTHORITY FOR INSPECTION OF THE DDCVA AND METER. SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA MUST BE SUBMITTED TO THE LOCAL AUTHORITY FIRE PREVENTION DEPARTMENT FOR REVIEW AND APPROVAL. A SEPARATE FIRE SPRINKLER PERMIT IS REQUIRED. 24 INCH MINIMUM 36 INCH MAXIMUM CONTRACTOR TO PROVIDE DESIGN, ENGINEERING AND DOCUMENTATION REQUIRED FOR ALL SYSTEM BRACING, HANGERS AND SUPPORTS. SIZE ALL RODS AND BRACE PIPES PER NFPA AND AUTHORITY HAVING JURISDICTION. RETAINER STRAP STEEL STRUCI FINISH FLOOR LEVEL ELEVATION VIEW OF DDCVA a CONCRETE DECK DROP —IN ANCHOR DROP —IN HANGER NUT WALL/COLUMN PERIMETER BEAM BEAM CLAMP EXPANSION BOLT SWAY BRACE END i BRACE PIPE ALL THREAD ROD HANGER RING ALL THREAD ROD HANGER RING �— FAST CLAMP TOP BEAM CLAMP LATERAL SWAY BRACE CONCRETE CONNECTION CONCRETE/STEEL SPRINKLER HANGER DETAIL WALL/COLUMN PERIMETER BEAM EXPANSION BOLT SWAY BRACE END BRACE PIPE SCALE: NONE SWAY BRACE END u-- PIPE CLAMP LONGITUDINAL SWAY BRACE CONCRETE CONNECTION Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP,BQC ACDUSRGt, AUBIO (2 NUEO k VECIW11CI3. ENGINEERING WEST N SfRRi SURE E SFAENE. WA F. 208) 378-0388 (20B) JJB-OB41 FPX Issue Mechanical Permit Set Date 8/09/2019 Sheet Title FIRE PROTECTION ABBREVS., LEGEND, NOTES, & INDEX Sheet n n300 (n W W Z V Ln LU 0 Z Q m + to F— V H V x FLAG NOTES: SHEEP NOTES: 1 > PROVIDE SPRINKLERS ABO'vE AND UNDER 1. PIPING IS DIAGWMMATC. PROVDE FITTINGS AND L' ROLL UP DOORS AS RECUIRED, TYPICAL OFFSETS AS REQUIRED TO AVOD VKRK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPUANT INSTAU ATIOJ. A B,1 C C,1 C. 9 5 F,1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 7,1 _ _ _----- _ JLL - - - - - - —+ - - - m - — — — — — — — I I I II I I I I I I ;I I I I I n I I I I I I ;I I I I I i n I I i I ,I I I I II I I I it i i I I I -.- - - - - - - - - -I -- - - - - - - - - - - - I I I I II I I I I I I I I I I I II I I I I I I �I 4.1 , —f -I I I i MATCH UNE - - - - SEE 1/M301S - II -- 3,9 II II STORAGE 131 FIRE PROTECTION DIAGRAM LEVEL 1 NORTH SCALE: 1/4" = 1'-0" I I DECO N EM DRY i ^3 ( SCBA 134 ® 1 5 3 ® ® ® 137 I I I I m I I I _ I ------------ I ----------------- ____=i - -- - - - - - - - - - - -I- - - - - - - - - - - - - - - - - - - - - L- - - I I I I I I I I I I I I I I I I I ' I I I I I I I I I I I ® - ------------------- I I I I I I I I I I I I i I I I I I I I I I ------------------J APP BAY - - 133 - - - ( - - - - - -B - 3 ,- - - - - - - - - - - - - - - - - - - - -i I I I I I I I I I I I I I ( I I I I I I I I I I I I I I I I I I -------------i------J 8 1, —---=------=----- i---- -=1----=------=-----=-- — — — — — — 126 CLEAN ® 132 CORRIDO� ® '. GEA 8 AS� I[] SHOP 138 I I I I iI I I I I I I' I I I I I I I I I I I I I' I I I I I I I I I I 1 I I li I I I I I ( I I I I I I I I, I I I I I I I I i I I _ MATCH UNE _ SEE 1/M301S Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG ffffflfff ; Issue Mechanical Permit Set', Date 8/09/2019 Sheet Title FIRE PROTECTION DIAGRAM LEVEL 1 NORTH Sheet M 3 O 1 N W ni I�1, —I I i I I I II I i t I �I i i I I I II I i I I I I 4,1 -- - - - - - - - - — — — — — — I 4 — — — — MATCH LINE - — SEE 1/M301N I I, 3.1 -- N N LL 2 — — — — — a co vi s O 1,8 — — — — Z c1 I I I I A FIRE PROTECTION DIAGRAM LEVEL 1 SOUTH SCALE: 1/4" = 1'-0" I I I I D NORTH I I I I E FLAG NOTES: SHEET NOTES: —1—t -DRY P&DANT SIDEWALL SIDE WALL HEADS 1. PIPING IS DIAGRAMMATIC PROVIDE FITTINGS AND L OR DRY S15TEA AS REQUIRED FOR OFFSETS AS REQUIRED TO AVOID WORK OF OTHER COVERAGE, TYPICAL TRADES AND AS REQUIRED FOR A CODE CC{MPUANT INSTALLATION. D 2 > FIRE SPRINKLER RISD2. MATCH LINE SEE 1/tvM301N 1 I I I I I I I Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC ACOg911CN. MI010 / NOEO & MECHWIGgt ENCINEE9INC i8W YhST p9q(FASON SfRFEi $OIiE 20$EAiitG NA 8 FM (206) }�g_0569 (206) 3>8-0641 FM N LU V �GRaEE W Ox gay z x m Ce I �I p SIOAr ���Y In V H S A B,1 C CA C, 9 7,1 4,1 --- — — — — MATGi LINE — — — SEE 1/9302S 3,9 FIRE PROTECTION DIAGRAM LEVEL 2 NORTH SCALE: 1/4" = 1'-0" yt` FLAG NOTES: SHEET NOTES: DRY PENDANT HEADS OR DRY SYSTEM, AS 1. PIPING IS DIAGRAMMATIC. PROMDE nTTINGS AND REWIRED FOR COVERAGE, TYPICAL OFFSETS AS REQUIRED TO AVOID WOW OF 01fB TRADES AND AS REQUIRED FOR A CODE COMPUANT INSTALLATION. DRY SYSTEM AREA F,1 I UNE — — — /M302S Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC AOWST AVOW / NOEO k HECHWICII ENGIrvF2RMC 1900 WpT fOLNFR90N SIPEEf SUOE Z01 ffWA FM I (206) 3J8-0589 (206) 378-00-0861 FAX Issue Mechanical Permit Set Date 8/09/2019 Sheet Title FIRE PROTECTION DIAGRAM LEVEL 2 NORTH Sheet M302N Ln od LU Z V Ln w 0 Z Q m -t- V' V w H S V l WE J n ow 4,1 — — — _ MATCH 11E SEE 1/M302N 3,9 1,8 — — — — — FLAG NOTES: SHEEP NOTES: DRY PENDANT SIDEWALL SIDE 1. PIPING IS MACR,"AX. PROVIDE FITTINGS AND WALL HEADS OR DRY SYSTEM, OFFSETS AS REQUIRED TO ADD WOW OF OTHER AS REQUIRED FOR COVERAGE. TRADES AND AS REQUIRED FOR A CODE COMPUANT INSTALLAIICN. �j PROVIDE WITH PRE —ACTION SPRINKLER SYSTEM. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUICH GROUP, 111C Issue Mechanical Permit Set Date 8/09/2019 Sheet Title FIRE PROTECTION LEVEL 2SOUTH Sheet n 302S t/1 W Z V LA W 0 Z 'Q m t!f E— V w H S V Q 1 _. J �' n r-L; 4 ,1 - - - - --- MATCH UPE SEE 1/M3020 3,9 9----------- FIRE PROTECTION DIAGRAM LEVEL 2 SOUTH ALTERNATE SCALE: 1/4" = 1'-0" I D NORTH FLAG NOTES: SHEET NOTES } DRY PENDANT SIDEWALL SIDE 1. PIPING IS DIAGRAMMATIC. PROMDE FITTINGS AND WALL HEADS OR DRY SYSTEM, OFFSETS AS REQUIRED TO AVC(D wCRK OF OTHM AS REQUIRED FOR COVERAGE, TRADES AND AS REOURED FOR A CODE COMPUANT TYPICAL. INSTALLATION. } PROVIDE WITH PRE —ACTION SPRINKLER SYSTEM. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH rROUP, INC c Era s��sawrs� V) C& W z V W 0 o°z z 22333 H fY f� f4 G'.11i^_ fA FLAG NOTES: S'.EEVE FOUNDATION WALL PIPE PENETRATIONS, T1RCAL REFER TO DETAIL IN XXX SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROMDE FITTINGS AND O!`FSETS AS REQUIRED TO AVOD WORK OF 01HER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. CA F. 1 sTRucTURAL DRAwNcs COORDINATE PENEIRATICNS WTH FCUNDATICN PLAN ON SHEET SXX'(. I I I I I I I I I I I I I I I I I I I I SCBA AIR 1 CNPRESSOR, 4'RWL BY FDIC DN '-- - - - - - - - - 2"V UPA N CT-1 i , S=5 Ld- 4'RWL FCO i ( 2"RAL UP �! O DECON MS D Y �\ e� BA 13-4 ' I ( 135 3S 4"RNt' "RWL UP 3� SHOP 2"R1hL UP RD 138 TO ORD P - - - - � 'RAL UP ( m l 10 ORD S=6 2„ (� LI - - -_ IJ %4"CA UP VfR HQ-2 %a'CA UPL4!'RW- UP r—------a H8=1 DN- - - - -- - - _ _- , a� - - - - - - - � HW, - -1 - - -- 3 — /2"H WC, - < °H l UP yzW,UP I it - I-- - - - ---- - - - -I- -- I I I I I II I , I I , I I , I i , I I , I I it I I � I I I I I li f � I i , I I I i � I �I TD-1 COMPRESSED AIR' HOSE REEL, TYP 4 � I I I I I I I I HRHR=A HR=A Ij— — — — — — — — —I — — — — — — — — — — — — — L — — - — — — — — — I HR W ( HR W WATER-Y4"CW, 1 %4"-Y4''CA, HOSE REEL, CA, UP 4d'CW 1Yi' TYP 4 ( CA, UP ' � I I Y4ca, " I I � I I II I ( I I I I I I ( I II I HRHR=A (� HRHR=A APP BAY n-- --t--------- 133 8 (---._-3 j- - - - - - l - - -'I - - - - - - - - - - - - - - - - — - - - I I -------------- - - - - -- GCO GCO HRHR=W HRHR=W O O I II I I i I I I I I II I � I I � I � I I I I i I li I Tom' I I i I I , I I I I II I I � I I I I I II I � I I � I I � I I � I I ' I - r- ------ r - - - - -- J 1 4,1 h"HWC, iV4"G, -_--_- HB 2 HBHB=2 ---------- - ----- -- ------------------------- 3VUP ---------------7---- --I-- ------------------ MATCH UNE - MATGH L NE ___-..... 126 i - SEE 1/M401S -_---- dR i CLEAgAD-1 3,9---------- � %"CA CONN TION ( � � �"CA CONNECTION ill 1 - ---°CA UP CTCT=1 STORAGE BW-1 "CA UP 131 GEAR WAS __- I i SS-1 4"RWL UP 11, CITY CI f 7TyOF 1 Ulli ILA AUG 2 0 2019 PERMIT CENTER Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC ACOUSfiGt, AU010 / VIOEO k MECHANICAL ENCINEFAINC (20) M-0 60N SIPEEf SUS 400 S378- "9 F. (208) 3�0-0569 (206) 3�6-0841 FAX Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PLUMBING PLAN LEVEL 1 NORTH Sheet M401 N J W I _il I I I it i i i I �I i i i i I it i i i I �I 4,1 MATCH UNE�� — — — — SEE 1/M401N Olt 'r i �I� CT-1N 7 STORAGE 2"W UP/DN CT-1 1, 8 --- — — — — — PLUMBING PLAN LEVEL 1 SOUTH SCALE: 1/4" = 1'-0" I I I I D NORTH I I I I E GOD O MATCH UNE _ SEE 1/M401N HB 1 3a'CW ON i i I 2"V ON i DOMESTIC HOT WATER FEXI � 1 J SEE QMESTI WATER SERVICE SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPUANT INSTA11ATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG V) w 4 EE 901 z U W STANDFIPE DRAIN, aRE Gy OQ 0 4 SEE 901 °o 2283 1� D �• w H T U Q D iiECEIVEI? CITY oF- l U1, W1LA Issue Mechanical Permit Set LU RATE AUG 2 0 2019 Date 8/09/2019 ILA PER'IVITAND APPROVAL PERMIT CENTER REQUIRED Oheet Title PLUMBING PLAN LEVEL 1 SOUTH LU (q Sheet M401 S SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROMDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE CCMPUANT INSTALLATION. A A,- B,1 C C,1 C, 9 F,1 I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I o- -o- -o- -a- -o- -o- -o- -❑- o- - -o- -o I _ I I I I I I I I I 2" CW SUPPLY RD ORD 2"VTR @ jq I RD. o� Y4"CW, %"CA ON 44" , 2"VTR Y4"H W, °"HWC, 3/a"CW ON Yi'HWC, BALL VALVE DN TO HBHB=2 DN HB-1 O - -f -- - — ----- --------- - - - --- -- - - - sl- -f - - - - - , I ---------- ----r--------- --=---- — --- --- - ---- — - _ — VACUUM BREAKER d c ❑ IIII I UHUH=3 UHUH=4 I ( I ill I I I I I I I I III I I I� I HOSE CONNECTION, COORDINATE HEIGHT FROM I FINISHED FLOOR AND CONNECTION TYPE WITH 2"CW (TRUCK FILL I I OWNER WATER OUTLET), ;II I SEE 2 (i' 2"CW, 3/4"HW, 402 4Ys"HWC, 1e"G, TRUCK FILL HOSE CONNECTION DETAIL ''''`QA 2 --- - ' SCALE: NONE -------- 'I I I I , I I - - - - - - - - - - - - - — ------ I I - -- I i _'4"CW1 1 V4" -Y4 CW, 1 /4" I I CA, UP CA, UP I I l I I II I 1 Yd'CA Ya"CA �--- — — — — — — — — — --- ---------------- I — ------------� II � I � IIII I l I I I I I I I III I I I I I ,---------, I ---------I III , I ❑ I 5 — — — — — — — — — — — — — — — — — — — — (' I I 2"CW, T'a'HW, Yz"HWC, I'/4"G, 1Ya'CA I I I I I I I Ili 1 I II I'I i�) I I I I 1 I I I (il I I l I , UHUH=1 UH-2 � I I 4,1 I I I I I I I 1"CW, �'a"HW, I I ❑ i 1"G - - - - - - - - - - - - - - - - - - - 1 /4"CA, DN - - - - - - T- - - - i I -------------------------------------- -- - 3-V - - - - - - - - - - - - — - - - - ----- - ---- - - - - - MATCH JNE _..._- -. ---_ 3"VTR -.- -_ MATCH UNE - - SEE 1/M402S 4„R SEE 1/M402S - - - - 4„RW- ON - - II CPT OFFICE UP 2"RW_ UP I I 2"RWL UP 2"RWL I x i 221 TO ORD TO O D p TO O2D 9'RW1 UP JRW UP l 14"RW1 } 1 91'RlM UP ! 1 Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG •�s�rrm Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PLUMBING PLAN LEVEL 2 NORTH Sheet M402N 0 W, F1 Ell R 4,1 — — — — — MATC SEE 3,9 2"VTR DISHWAS SEE ( Q------ -- I I I I I I I I A B C C,1 PLUMBING PLAN LEVEL 2 SOUTH SCALE: 1/4" = 1'-0" I I I D NORTH SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTAIJ.ATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GRIENBUICH GROUP, INC 3itfR�ilAiL Ln V Q I �= I P19 III Ii I i 2"CW, Y4"HW, Yz"HWC, 1A"G, 1 1/,"CA i I I I I I I I III I I II I'I 'I' I I I I I I I I I,I I I l ti 111 I I UHUH=1 UHUH=2 III ,II I 411 1'G I Yz HWC,a1HWG, - - - - - - - - - - - - - - - - - - — - - - 11/4"CA, DN - - - - - - - - - - — _ ------------------------------------------- - - 3VTR - - - — -- - — MATCH NE MATCH LINE - — SEE 1/M402N- - SEE 1/M402N 11 4'RWL 3,9 4'RNL DN - --, - - II Ii7� 3:1 2"VTR 9 - - - - - — DISHWASHER, 7 SEE M901 TYR (2)-- - - - - 4"RWL DN 1:8 ---- - - - -- Ili CPT OFFICE 2"RWL UP 2"RVL UP H I/ 2"RWL UP 221 TO ORD TO OD TO ORD 27RW_ UP 7Ril UP 4"RW- ( "R UP C0F2-15F TO RD T' RD 11- (O - - I I II STATION OFFICE I U5EXPLR a 4"V DN/ I I I-- I - - BACKUP EOCf TR WING - - -- _ --- -F3- • -'^'^ - -' " 210 - - - - - - CHIEF I 11 /4"HW, 3a"HW, 1 - _ i fro 11 1)/z"CW, 1 h"HW, Yz CW, �/a HW, _ BACKUP EOC STOR- 20 L YI"HWC Yz HWC - 212 L i I Yz"HWC"HWC I - IWC-1 WC 1-� -- ---- S-2 - (._l, a _ - - -Tsa3 .. tiR �"`: -- __ (�'��� - - - I t---n 223 21 T I'--3--- I_ 1 h„CW 3/a"HWC, DN T Y2 HW, 2"V ON 4'VTR I 2"W DN -III �ur'n�n"HwC I_'_ -.--- - 2"VTR CORR IIi l I_f1U n�u�. t1 21s i I I „ - - y L - i l t , =2 W9-2 I III ®® 209y„CW i - L_t WC=2 S-I I I Y2"HW DN I 2"CW, 1'a°HW, L--_ I I WIC =1 oo ® 3/4"HWC I — 2 - L2 _ 4"V Yz DN 4�a'HW, i UtiCtd I °HWC _ p 4" DN -_ 3a'G DN I-4s FCO 2"RWL UP I I =- _ - _ - - T. 2 F2Vt P -- -I i TO CRD � I I - TO ORD - - L - -4"VTR- - - - - - - �GR T RM �7--_____- __��I -� rtJ 4'Ryd_ I I I 4„VTR �----- �'.24-�----______ Lam' CORR 4"RWt ( I------------- 2"RNd UP TO RD - - - 9 - - - - -- - - - --- - - - - - - - - - - - - --- ----- ---- 2"RWLUP I I - - - - ---Il it UII I I TO RD I - -I ---- - - -- -- I I 011 OII - III II II II OII II II OII ADMIN/ SUPPORT _ II II U II ASST CHIEF ASST TO FIRE CHI P02 I[,[1I lilt 204 203 I itll D231ECK II It 'Y4"G ON q II II H/ BC 20 O M. CRD 4''RWL DN I I I I I i I I I I I I I I I i I I I I I I I I I 1 I I IIECEIVEI) CITY CE i"i{KWILA A B C C.1 D E E gMACIAAI In nA norm -IT-TFI-F IB [_L-�MJ2 -2 / SHEET NOTES: 1. PIPING IS DIAGRAMMATIC PROVIDE FlTTNGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTAUATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREE^NIIUSCII GROUP, INC ALW!$IIGN., AU910 / v19E0 k MECfWVICN. ENGINEERING 1900 NfSf IeCNEi60N STREET SUITE 291 EEAiRE WA FM 88 (200) 3]8—�389 (106) J]8-9541 Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PLUMBING PLAN LEVEL 2 SOUTH ALTERNATE Sheet M402S.A R, L FLAG NOTES: SHEET NOTES: I 1 > PRONDE N-SWTCH TO SHUT OFF HEAT 1. DUCT WORK IS DIAGRAMMATIC, PROVIDE FITTINGS AND MEN DOORS OPEN. OFFSETS AS REQUIRED TO AVOID UIORK OF OTHER TRADES AND AS REWIRED FOR A CODE COMPUANT INSTALLATION. A B,1 C CJ I I I I I I I I I 10" TO 4 14"0 UP TO E 8"0 UP TO EFFF=6 j - lo'VI EG4 200 EG2 G7 EG7 - - - - 300 00 300 10"0 10"4 EG2 i 750 DECON EMS DRY I MS SCBA 134 135 36 137 'EG2 138 I I I SD15 EU=1 = EUH-3 EUH-4 300 2D 0p L - - \ ` EUH-6 7,1 SD16 ---- �150 (TT ® ® 650 - - - - - - - - EUH-2 — - ^— - - - - - - - 0 UP - " 10- - - -- ------------------=- -- - --- =-— - - - -- - TO RV-2 - 711'� - — - — - - - — - — - — - — — - — - — - — - -F-------------I------- i I ' I i I ' I I it I I I I I I I I ' I ' I I I II I I I I I I I I I I I I I I I � - - El 3 El -------------------- I I II I � I I I I I � I � I I it I I I I I I I I i I I I I ' APP BAY - ------------- 133 ®===l3 - --- - - -il - - - - -I - - - - - I - - �- I I I II I I I I I I I I I I I I I I I I II I ( I I I I I I I I I � I � I � I � I I I - t-------------I-- - - - -� I I ® 1= — — — — — — — — — —i — — — — — — — — — — — — — — — MAIOH U E - - - - SEE 1/M501S -- _ hlititt -- 0T © 126 CLEAN 132 39 D A 100 11' 0 I 8 0 ', STORAGE 131 I 150 q14 128 200 I � P4 F===4L---, EAR WAS I s � 111 00--1% HVAC PLAN LEVEL 1 NORTH SCALE: 1/4" = 1'-0" MATCH UNE SEE 1/M501S REVIEWED FOR CODE COMPLIANCE APPROVED SEP-I8-2019— —Ciu7cwtla 3U11.QiN.G DUVt,Grn'tir- - nECF1VV0 CITY OF i i K—WILA► AUG 2 0 2019 PERMIT CENTER Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC srrM+Psstes ! Issue Mechanical Permit Set Date 8/09/2019 Sheet Title HVAC PLAN LEVEL 1NORTH Sheet n 501 N V1 W W z V V) w 0 z a m L LLJ u a D LL1 vi LLJ 4,1 — — — — — — 4 — — — — —- MATCH UNE _ _ SEE 1/M5011 3,9 WALL CAP �1 — — — — —- L8 — — — — —- I I I I I I I I I I I I I I I I A B C C,1 HVAC PLAN LEVEL 1 SOUTH SCALE: 1/4" = 1'-0" I I i I D NORTH I I I I E SHEET NOTES: 1. DUCT WORK IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. 2. COORDINATE IDU INSTALLATION HEIGHT WITH ARCHITECT, TYPICAL ALL UNITS. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENRUSCH GROUP. INC fiMigMlk Lrk T I l2Ff'i fit�'.'a FLAG NOTES: 6.9 (D- SE 1/M502S B. 1 C C,l C, 9 F11 HVAC PLAN LEVEL 2 NORTH SCALE: 1/4" = 1'-0" 0 NORTH FUMBLE EXHAUST DUCT DROP FROM TRACK TO VEHICLE OCNNECTOR. PROVIDE DOOR SNTCH ON APP BAY RCLL-UP DOCR TO SHUT OFF HEAT WHEN DOOR IS OPEN, TYPCAL PROVIDE DOOR SMTCH ON PHYSICAL TRAINING DOORS TO TURN OFF HVAC MEN DOORS ARE OPEN. CEILING FANS TO REMAIN FUNCTIONAL REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 City of Tukwila SHEET NOTES: 1. DUCTWORK IS DIAGMMATC, PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE ODnANT NSTAiATION. Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP. INC NOtg= '3M- a 9719 Issue Mechanical Permit Set Date 8/09/2019 Sheet Title HVAC PLAN LEVEL 2 NORTH Sheet 11 A IV1502N- I I LIT I 4,1 �- - - - -- _ MATOH UNE _ SEE 1/M502N 3,9 UP TO RV-13 RESIDENT KITCHEN Q/ — — — — — 18 - - - - - I I i I I I I I I I I I I I I I A B C C,1 HVAC PLAN LEVEL 2 SOUTH SCALE: 1/4" = 1*- 0" I I I I D NORTH I I I I E H- SHEET NOTES: 1. DUCTWORK IS DIAGRAMMATIC. PROVIDE FITi1NGS AND OFFSETS AS REQUIRED TO AVOID WCW OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPUANT INSTALLATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC —USMAC M 10 / MMO h MECNANibJ. ENGINMN0 (200NICNFRSON 5t9EET SUifE 201 561111£, WP 90119 (200) 3>6-0569 (ZO6) 3)8-0841 PRX In W W z V GREY VI W 'oF w c, r) I a z n� az Not D I I PECEWECs 4.1 - - - -- — — — MATCH LINE — SAE 1/M502N 3,9 UP TO RV-13 ca LO LL EL LL F— J N O RESIDEN1 rn KTCHEN w z m a� a cN N CQ 0 Z O HVAC PLAN LEVEL 2 SOUTH ALTERNATE SCALE: 1/4" = 1'-0" I I I I I I I I I I I I I I I A B C C,1 i I I I D NORTH I I I I E SHEET NOTES: — - 1. DUCTWORK IS DIAGRAMMATIC. PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVGD WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT NSTAI-LATICN. 2. COORDINATE IDU INSTALLATION HEIGHT WITH ARCHITECT. TYPICAL ALL UNITS. Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENEUSCH GROUP, INC Acoumcu. Auoio�>7ocro a Mccxuncu. ExanEEnwc 1800 WEST SfflFEi SUBE R01 SEAiiLE, WA 86118 (206) 3J8-056-O566 (206) 3J6-0861 FAX In � V w H S U Q Q SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND OF SETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION. A B,1 C C,1 C9 F.1 I I I I I I I I I I I I I I I I I I I I I i I I I I I I I I - - - - - - - I I DECON EMS DRY IMS SCBA 134 135 g CB �71378 138 I �L I , � _ 7�--- - - - - - - - - - - - —----=------=-----------=1---�--=-----=-— - - - - - -- --- - - - - - -- - - - - — _ _ I ll ❑ -- ' I - - - - - - - - - - - - L- - - - I i I I it I I I I I I I I l I ' I I , I I it I I i I I I I I p I I I it I I I I I I I I l I 6 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — El AI it - I I I I I II I I I � I I ' , i I , I � I - I ------------- I I I I � I I APP BAY 133 I I I l I S- - - - - - - -I - - - - -I - - ®=====3 - - - - - - III - - I I it I I --- -----------T I I I I I I I ' I I I I ' l I I ' i i it I � -r-----------� ® 1 � I 4,1 - - - - - ---=-----=----- r---- =------=-----=-- - EI - - - - - MATCH LINE -=i_.-_= 3,9 SEE 1/M5035 — _ __------ , 126 CLEAN 132 ` GORRIDOR 130 e STORAGE 131 1 GEA 28 ASI� F II � 11 , PIPING PLAN LEVEL 1 NORTH SCALE: 1/4" = 1'-0" REVIEWED FOR CODE COMPLIANCE LBUILDINGDIVISION D— - 9 - MATCH Una _ 1/M5o3s -a Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC i119aitq! Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PIPING PLAN' LEVEL 1 NORTH' Sheet M 503 N i 1 4,1 — — — — MA1 — — — SE 3,9 3,1----------- ----------- PIPING PLAN LEVEL 1 SOUTH SCALE: 1/4" = 1'-0" I I I I D NORTH I I I I E SHEET NOTES: 1. RRNG IS DIAGRAMMA110 PROVIDE FITTINGS AND OFFSETS AS REQUIRED TO AVOD NOW OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTA iAl10N. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENHUSCH GROUP. INC AWU9I1C4. AV6I0 I NDEO t n 2.1 OT 2111.01,9 (2 6) 3 8-05 6N SIflEEt 906E 261 9FAtilE, WA 9 F19 (208) 3'l8-0569 (208) 3]6-0641 FA% Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PIPING PLAN LEVEL 1 SOUTH Sheet M503S V) Cie z v In w 0 z a m W ILI V V w V Q LLJ Un SHEET NOTES: 1 . PIPING IS DIAGRAMMATIC. PROVIDE FITTINGS AND 0=- AS REQUIRED TO AVOID WOW OF OTHER TRADES AND AS FEQURED FOR A CODE COMPUANT INSTALLATION. B, I C CA F. 1 (D-- MATCH UINE SEE I/M504S ncvftvvtu FOR CODE COMPLIANCE - APPROVED SEP 10 269 City of Tukwila BUILDING DIVISION Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC MM 201 �M WA 0119 378-0569 (206) 3-0641 M z rr -tp- #I- V) LLJ U3 LL t-- C14 U) LL U) 2 M .e IL co iri C11 D 5 SEE 1/M504N Q-- PIPING PLAN LEVEL 2 SOUTH SCALE: 1/4" = 1'-0" NORTH I LINE I/M504N REVIEWED C', COMPLIA NCE APPROVED SEP 10 2019 City of Tukwila BUILDING, DIVISION] r 11ECFIVED CITY OF TU N WILA AUG 20 2019 PERMIT CENTER SHEET NOTES: 1. PIPING IS DIAGRAMMATIC. PROVIDE FTTIINGS AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT NSTAiATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG ThE GREEnBISCH rR04P,1NC SkY" try 206> 378-0569 (—) 378-- F. Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PIPING PLAN LEVEL 2 SOUTH Sheet M504S_ Ln Ce UJ z U V) UJ 0 z M Cd LA X U ry MCI I 4,1 04— MATCH 1111 SEE 1/M504N 3,9 GO GO LL LL M M 2 UL CID CD oie z (6 PIPING PLAN LEVEL 2 SOUTH ALTERNATE SCALE: 1/4" = 1'-0" NORTH i LINE 1/M504N REVIEWED FOR CODE COMPLIANCE APPROVED SEEP 10 2019 City of Tukwila BUILDING DIVISION SHEET NOTES: 1. PIPING IS DIAGRAMMATIC PROVIDE F17NGS AND OFFSETS AS REWIRED TO AVOID WORK OF OTHER TRADES AND AS REWIRED FOR A CODE COMPLIANT INSTA100N. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREEN13USCH GROUP, INC 11. 201 .119 (206) 37S-0$69 (—) — Issue Mechanical Permit Set Date 8/09/2019 Sheet Title PIPING PLAN LEVEL 2 SOUTH ALTERNATE Sheet M504S.A In ce UJ z In UJ z co F— U I I 01%, I SHEET NOTES: 1. DUCT WOW IS DIAGRAMMATIC PROVIDE R TINCS AND OFFSETS AS REQUIRED TO AWD W RK OF 01HER TRADES AND AS REQUIRED FOR A CODE CUAIUANT INSTALLATION. Q 7,1 �D — — — — — 4,1 MATCH UNE SEE 1/M601S 3.9 MECHANICAL ROOF PLAN NORTH SCALE: 1/4" = 1'-0" REVIEiiVED FOR -CO S:CiMPPPLIANCE-- — APPROVED H UNE SEP-1'O-2 1 1�Mso1s City of Tukwila [BUILDING DIVISION RECEIVED CITY CP `i't I-WILA AUG 2 0 2019 PERMIT CENTER Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE . XOU e,T •Ik�.HaM � 3 Issue Mechanical Permit Set' Date 8/09/2019' Sheet Title MECHANICAL ROOF PLAN NORTH Sheet M601 N N LU W z V V) w 0 Z Q m a -F LA F- w F- V Q Q LU V) i 4,1 -- — — — — MATCH UNE SEE 1/9601N 3,9 MECHANICAL ROOF PLAN SOUTH SCALE: 1/4" = 1'-0" i i i D NORTH ATCH UNE _ EE 1/M601N SHEET NOTES: 1. DUCT WOW AND PIPING ARE DIAGRAMMATIC. PROMDE FITTINGS AND OFSETS AS REQUIRE) TO AVOID WOW OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPUANT INSTAU.ATION. Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG ss�e�rsa Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL ROOF PLAN SOUTH Sheet n n601 V V) W W Z U_ V) W 0 Z Q CC1 N I— L) W v rx i ON ROOF ROOF UH-2 UHUH=1 200 MBH 200 MBH c� c� 0 0 N SECOND FLOOR UHUH=2 UHUH=1 00 MBH 200 MBH c� c� 0 0 0 0 N N (400) 11/a"G TWO -POSITION MANUAL RESET SOLENOID VALVE. CLOSE ON ALARM CALL RANGE Ll 50 MBH E (50) (100) BBB( 100 MBH SECOND FLOOR (850) (1150) o (a o M F-1„G� o � PRV. VENT FULL SIZE TO EXTERIOR, TYP DHWH DHWH FIRST FLOOR 150 MBH 150 MBH FIRST FLOOR ROOF GAS RISER DIAGRAM SCALE: NONE COMPRESSED AIR RISER DIAGRAM SCALE: NONE MEDIUM PRESSURE L-4 TO SITE GAS 2 LB. GAS METER, SERVICE CONNECTION SEE 11/4°CA 1 Yd'CA ROOF RISER DIAGRAM NOTE: MAKE ALL CONNECTONS TO THE COMPRESSED AIR MAIN FROM THE TOP, SEE 9M90 SHEET NOTES: 1. DUCT WORK AND PIPING ARE DIAGRAMMATIC. PROVIDE FITTING AND OFFSETS AS REQUIRED TO AVOID WORK OF OTHER TRADES AND AS REQUIRED FOR A CODE COMPLIANT INSTALLATION, REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 City of Tukwila BUILDING DIVISION nEC►IVEff CIT! OF TiiKWIL A AUG 2 0 2019 PERMIT CENTER IRev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENRUSCH GROUP, INC t AUS(ICN. AU010 NDEO k MEciUNtt',N. ExGME - 1800 KESi Nipf SiPEET - xt SFAiiIE. - 88119 (i08) 878--. A) 8)8-0841 FM Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL LARGE SCALE PLANS Sheet n 701 1 W I THERMOSTATIC MIXING VALVE, LEONARD OR ACCEPTED EQUAL — THERMOMETER--- HWC DHWCP BALANCING VALVE, TYP. SHUT—OFF VALVE, TYP. UNION, TYP. CHECK VALVE, TYP. P&T RELIEF VALVE SEISMIC RESTRAINT STRAPS, TYP PROVIDE IN COPPER PIPE TO DRAIN DRAIN PAN PIPED TO DRAIN HOUSEKEEPING PAD, REFER TO ARCHITECTURAL HEAT TRAP, TYP �1 r u i r I DHWH 1 i DOMESTIC GAS WATER HEATER DETAIL SCALE: NONE REDUCED PRESSURE BACK —FLOW ASSEMBLY - PRESSURE GAUGE (TYP) STRAINER MAIN SHUT—C TO CW QFR\/H NORMALLY OPEN VALVE EXPANSION TANK VENT TO ATMOSPHERE PRESSURE REGULATOR (2 PSI — 14" WC) CSA RATED FLEXIBLE GAS CONNECTION, VERIFY WITH AHJ PRIOR TO INSTALLATION DIRT LEG :-113" COMBUSTION AIR INTAKE/ 3" FLUE EXHAUST, EXTEND AND CONNECT TO ROOF CONCENTRIC VENT ROUTE CONDENSATE TO DRAIN HOSE END DRAIN VALVE PROVIDE CONDENSATE NEUTRALIZER PER SPECIFICATIONS DRAIN FUNNEL DRAIN TO BUILDING EXTERIOR PRV UNION (TYP) SHUT—OFF VALVE (TYP) r—TO BUILDING GLOBE PRV BYPASS NOTE: CONTRACTOR IS RESPONSIBLE FOR SETTING PRV'S TO PROVIDE ADEQUATE FLOW AT MOST REMOTE FIXTURES DOMESTIC WATER SERVICE ENTRANCE DETAIL NOTE: INSTALL PER TI- MANUFACTURER' INSTRUCTIONS EXHAUST AIR PIPING FROM WATER HEATER CONCENTRIC VENT DETAIL SCALE: NONE RELIEF VENT CONTRACTOR TO ARRANGE STACK PAY AND INCLUDE COST IN CONTRACT FOR BRINGING RELIEF VALVE GAS TO THE BUILDING AND SETTING THE METER BY—PASS VALVE RELIEF SHUT—OFF VALVE REGULATOR SHUT—OFF VALVE, \-FILTER uuuuuuu AIR SHUT—OFF o a o o DIAPHI METER rATER VALVE BY—PASS VALVE o 0 0 0 0 0 �;.. WALL SLEEVE LINK SEAL, WATERTIGHT UNDERGROUND PIPE SLEEVE THROUGH FOUNDATION WALL DETAIL ADJUSTABLE METER STAND GAS METER ASSEMBLY DETAIL (DIAPHRAGM TYPE) SCALE: NONE NOT USED SCALE: NONE M901 SCALE: NONE M901 SCALE: NONE 2—TON LIFT ANCHOR (2 EA. SIDE INLET PIPE SAMPLING T BY OTHERS 28)h"I.E. TO BOTTOM 4" 0 INt PIPE FLOW C BAFFLE SEDIMEt OIL —WATER SEPARATOR DETAIL SCALE: NONE NSERT, W/ IOLT (2 EA. :T PIPE SAMPLING Y OTHERS 4"0 OUTLET PIPE NOT USED SCALE: NONE L MIC ATED T—OFF E I FIELD SUPPLIED FUEL LINE REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY QF yul,F WII_A AUG 20 2019 PERMIT CENTER Rev Date Issue Tukwila Fire Station 52 Project No. 17012' Designed by JWG'', Drawn by JEA' Checked by JWG' THE GREENBUSCH GROUP, INC IfAUS11W. MAIq / NOEfI t MECN1V T ENGINEERING 1900 WFS! NICKFRSON STPEEf SUfiE ZOt $fAiit£ WA 881f9 M.) 3J8-O I-) 3JB- , FM Issue Mechanical Permit Set'. Date 8/09/2019', Sheet Title MECHANICAL DETAILS Sheet Mg01 Le SPRINKLER SYSTEM DRAIN —� TWO DRAIN PIPE DIAMETERS PROVIDE Y2" SCREEN MESH CAP FOR RODENT PROOFING 36" MIN PER UPC 312.12. —7 6" DIAMETER STAND PIPE DRAIN 42" MIN MINIMUM 4" DRAIN TO SANITARY —� FINISHED FLOOR 1-M-11,11111MINui 0-1 10 SCALE: NONE �1 SINK AIR GAP----, -- COUNTER WATER HAMMER ARRESTOR DEVICE DISHWASHER VENT TO ROOF WATER HAMMER 2"W TO ARRESTOR DEVICE I SEWER I 1/2"CW SUPPLY C P—TRAP C /2"HW SUPPLY 7/a" WASTE FLEX HOSE (TYP) CONNECT TO NEAREST FREQUENTLY USED FIXTURE'S WATER SUPPLY, OR NEAREST CW LINE TIMER BOX — 115 VOLTS, PROVIDE UNISTRUT I —) ASSEMBLY TO SUPPORT BOX ACCESS DOOR, SIZED TO ALLOW UNOBSTRUCTED ACCESS TO COMPONENTS, ' MIN. 16" X 16" 6' SOLENOID CONTROL CABLE -Ya"CW (TYP) TRAP PRIMER DETAIL SCALE: NONE At-,l \\1 TO FIXTURE (OR AS SHOWN) SOLENOID VALVE TRAP PRIMER VALVE PRIMER MANIFOLD (S) (WHERE SERVING MORE THAN ONE FLOOR DRAIN) FINISHED FLOOR TO FLOOR DRAIN TRAP (TYP) CLEANOUT PLUGS & AT EACH CHANGE IN DIRECTION r--DRAIN LINE PIPING SHALL TOWARDS DISCHARGE NOT INTERFERE WITH ACCESS TO EQUIPMENT FULL SIZE VENT (OPEN END) 12T A" \ — EQUIPMENT DRIP PAN 45 DEG CUT WHEN ROUTED TO COUPLING OR UNION FOR LONG FLOOR DRAIN DRAIN LINES. SPILL TO DRAIN OR CONNECT TO ROUTE DRAIN PIPING TO NEAREST DRAIN FIXTURE TAIL PIECE FIXTURE TAIL PIECE OR FLOOR DRAIN AS SHOWN ON PLAN. SIZE SHALL BE FULL SIZE "A" SHALL BE EQUAL TO THE OF UNIT'S DRAIN OUTLET OR 11/4", WHICHEVER PLENUM NEGATIVE STATIC IS GREATER. "B" SHALL BE EQUAL TO 1/2 THE PLENUM MAXIMUM NEGATIVE STATIC PRESSURE TRAP AT CONDENSATE DRAINAGE PIPING SCALE: NONE REGULATORLJ�V " GAS REGULATOR VENT TERMINATION AT ROOF SCALE: NONE SHUT OFF REEL DIRT LEG T I COMPRESSED AIR COLD WATER u COMPRESSED AIR & WATER HOSE REEL DETAIL SCALE: NONE IU tLLJ A I VtIN I D PREVENT JETRATION SPILL RESISTANT, PRESSURE VACUUM BREAKER REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 City of Tukwila BUILDING DIVISION nECEWED CITY OF i i;;:wtLA AUG 2 0 2019 PERMrr CENTER Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENEUSCH GROUP, INC ACDUSNGV. 11101 N0E0 k MECWNICM. ENGINEERING 1900 WFSE NIGNER50N StRFEI 5011E M11 9EATIIE, WA 98119 - (200) 3)80 (208) m- , PAX Issue Mechanical Permit Set Date 8/09/2019 i �, 01 IN L.11 DISHWASHER CONNECTION DETAIL SCALE: NONE NOT USED SCALE: NONE (M902 NOT USED SCALE: NONE Sheet Title MECHANICAL DETAILS Sheet M902 FD-2 AIR COMPRESSOR DETAIL SCALE: NONE PIPE SUPPORT TRAPEZE DETAIL SCALE: NONE 4 PRESSURE GAUGE M " ALLTHREAD, ATTACH SECUREEY TO STRUCTURE (TYP) FLAT WASHER W/ HEX NUT (TYP) SEISMIC SWAY CABLE PER SMACNA, ANCHOR SECURELY TO STRUCTURE, (TYP). CW, HW, HWC CHANNEL STEEL SUPPORT, 1 §'s"x15A"x12 GA FLAT WASHER WITH (2) HEX NUTS (TYP) —PIPE, SHIELD WITH HEAVY DENSITY INSULATION OR PROTECTION SADDLE STEEL ANGLE, 2x2x.125 SPAN STRUCTURE AND SECURE, COORDINATE INTERMEDIATE STEEL MEMBERS AND ATTACHMENT REQUIRED WITH TO COMBINED COMBUSTION BUILDING CONTRACTOR AIR/VENT, SEE Q 2x2x.125 STEEL ANGLE HANGERS AND SEISMIC CROSS BRACING VENT TO ATMOSPHERE, STEEL ANGLE, HEAT BOLT TO UNIT HEATERR SEE SUPPORT POINTS UNIT 9Q HEATER UH ADJUST DIRECTIONAL PRESSURE REGULATOR VANES FOR THROW G (2 PSI — 14" WC) SEE ARCHITECTURAL FOR INSTALLED HEIGHT ABOVE FLOOR GAS UNIT HEATER DETAIL SCALE: NONE DIRT LEG �AGA RATED BALL SHUT—OFF VALVE GAS FLEX CONNECTOR INSTALL INTERNAL WATERGUARD IN ALL INSULATED ROOF, SEE ARCHITECTURAL OVERFLOW ROOF DRAINS POLYPROPYLENE DOME, TYP FLASH ROOFING INTO DRAIN, TYP DRAIN RECEIVER, TYP NO —HUB SIDE VIEW 2 CONNECTOR, TYP PREFABRICATED TRENCH DRAIN SECTION SLOPE TO DRAIN —� �— SLOPE TO DRAIN CLAMPING � RING WASTE CONNECTION SECTION VIEW REFER TO ARCHITECTURAL FOR FINISH TRENCH DRAIN 4" CONCRETE SLAB —► ° .d ;° ^ , < . --4" CONCRETE SLAB INSULATE AROUND ENTIRE DRAN ASSEMBLY, FOR I CONDITIONED SPACES DETAIL NOTES: //��, ° s a /i CLEANOUT, TYP 1. SET TRENCH DRAIN IN CHANNEL SURROUNDED BY 6" OF CONCRETE WITH A MINIMUM OF 3,500 P.S.I. SLOPE CONCRETE OFF THE ,.° . ', ORL, SIZE TOP OF AND AWAY FROM ° a° PER PLANS THE DRAIN. WASTE CONNECTION & P—TRAP NOT SHOWN 2. INSTALL PER RAINWATER LEADER, MANUFACTURER'S WRITTEN COMBINE IN INSTRUCTIONS. VERTICAL, TYP TRENCH DRAIN TD-1 DETAIL SCALE: NONE LUG M ACI END PIPE Arvin SECTION NOTE: HANGER SHALL NOT CUT INTO INSULATION SEISMICALLY SUPPORTED CLEVIS HANGER DETAIL SCALE: NONE EXHAUST TERMINAL SEAL WITH HIGH TEMPERATURE SILICONE RUBBER SEALANT SUPPLIED WITH KIT — COMBUSTION AIR INLET FLASHING ROOF COMBUSTION AIR PIPE CONCENTRIC ADAPTER, ATTACH TO ROOF WITH BRACKETS COMBUSTION AIR PIPE NUu VITH ROD TALLIED NUT NGER ) WITH d SADDLE 36" ABOVE ANY SURFACE WITHIN 10 FEET FLUE EXHAUST PIPE 18' MIN. 4' MAX. I f III+ ROOF IS COMBUSTIBLE UNIT HEATER COMBUSTION AIR VENT DETAIL SCALE: NONE FLUE EXHAUST PIPE ROOF DRAIN DETAIL SCALE: NONE SECTION INSULATION (TYP) PIPE (TYP) rJP[4JR6011100ldll�0*19M T7IA1—MMO I.ZY7: PIPE SUPPORT WALL MOUNT DETAIL SCALE: NONE ELEVATOR PIT FINSHED Ft FLOE 9 l SUMP PUMP DETAIL M903 SCALE: NONE BODY PIPE Iffe )ATION ECK VALVE TE VALVE SUMP PIT REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2019 AP PUMP '' City of Tukwila ON BUILDING DIVISION nECEIVEtn CITY OF TUII .'ILA AUG 2 0 2019 PERMIT CENTER e d IRev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC MEwrwAs '�s .`�' • � T Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL DETAILS Sheet M903 0 rW-1-10m CURB, F AND CC FLASHIN CANT S ROOFIN( ROOF D R38 RIC INSIDE DUCT P OPENIN( DUCT Dav TYPICAL ROOFTOP EQUIPMENT CONNECTION DETAIL SCALE: NONE CONDENSATE, ROUTE TO DRAIN PER MECHANICAL PLANS- RS, RL REFRIGERANT PIPING FROM OUTDOOR VRF UNIT RS, RL REFRIGERANT PIPING LINES TO VRF INDOOR UNITS, TYP - ATTACH HANGER ROD SECURELY TO STRUCTURE, TYP- RS, RL REFRIGERANT PIPING FROM OUTDOOR VRF UNIT - CONDENSATE, ROUTE TO DRAIN PER MECHANICAL PLANS - UCT TRANSITIONS FROM QUIPMENT TO DUCT SHEETMETAL COVER WITH RECEIVER FOR COUNTERFLASHING HIGH -DOMED, CAPPED, GASKETED FASTENERS (APPROX. 18" O.C., DEPENDING UPON LOCAL WIND ZONE AND LOCAL CONDITIONS SHEETMETAL COUNTERFLASHING FASTENERS, APPROX. 8" O.C. OPTIONAL: EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT CURB STEEL OR WC CANT ROOF DECK CURB FLASHING DETAIL SCALE: NONE HATCHED AREA INDICATES CLEARANCE SPACE PER MANUFACTURER ATTACH SEC STRUCTURE THREADED F MAINTENANCE HANGER, TYI r ACCESS HATCH, / \ COORDINATE WITH ARCHITECTURAL REFRIGERAN / \ I DRAWINGS (RL) AND S (RS) PIPING / \ I CONTROL BOX \f i BC-1 BRANCH CONTROLLER PLAN VIEW L RS, RL REFRIGERANT PIPING TO BRANCH CONTROLLER BC-2 —VIBRATION ISOLATORS, MASON 30N OR EQUAL RS, RL BC-1 REFRIGERANT 0 PIPING TO BRANCH CEILING CONTROLLER BC-2 ELEVATION VIEW JJV MAINTENANCE ACCESS HATCH, SHOWN IN OPEN POSITION. COORDINATE WITH ARCHITECTURAL DRAWINGS _J NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. BRANCH CONTROLLER BC-2 INSTALLATION SIMILAR BUT UNCONCEALED. BRANCH CONTROLLER DETAIL SCALE: NONE y[iZ�7��ZiPtq CEILING RECESSED VRF UNIT (IDU) DETAIL SCALE: NONE NOTE: THE SUPPORT SYSTEM SHOWN IS THE MINIMUM MATERIAL THICKNESS AND STRENGTH! CONTRACTOR SHALL DESIGN FINAL SUPPORT SYSTEM, CAP PIPE IDENSATE NG, SIZE PER 4UFACTURER'S TTEN FRUCTIONS, ITE TO REST DRAIN —.4gre 1V4"X11/4" 14-GAGE, CROWN DUCT IN CENTER TO GALVANIZED G90 SHED WATER TO EITHER SIDE C-CHANNEL, TYP HORIZONTAL MEMBERS — SHEET METAL DUCT BOTTOM OF DUCT TO ALLIGN WITH GALVANIZED G90 2Y2„ OPENING AS SHOWN ON THE SCHEDULE 40 PIPE. ARCHITECTURAL DOCUMENTS, APPROX. BOLT W / WORKING NUT 114" ABOVE THE ROOF, FIELD VERIFY. TO ADJUST PIPE HEIGHT I I 2Y2" GALVANIZED G90 PIPE GALVANIZED C90 2" SCHEDULE 40 PIPE. EXTEND MINIMUM 24" ABOVE ROOF. 1" BOLT AND LOCKING NUT BRACE AND FLASHING AT ROOF DECK PER 2" GALVANIZED G90 PIPE ARCHITECTURAL ROOFING ROOFING y- REFER TO ARCHITECTURAL 1�CUT ROOF AND ATTACH TO DOCUMENTS FOR INSTRUCTION STRUCTURE PER ARCHITECTURAL ATTACHING DUCT SUPPORT DOCUMENTS TO STRUCTURE EXTERIOR DUCT CONSTRUCTION AND SUPPORT DETAIL SCALE: NONE POWEF EXHAL & COL FLASH ARCHF CURB ROOF EXHAL ROOF EXHAUST FAN DETAIL SCALE: NONE BIRD/INSECT SCREEN SEE SCHEDULE FOR TYPE INSULATED ROOF STORM PROOF BLADES GASKET LAG SCREW CURB, FLASHING AND COUNTER 8 FLASHING, SEE M`801 ROOFING BY GEN. TRADES--- SEAL OPENING DUCT INSULATION RELIEF DUCT — ROOF VENTILATOR DETAIL SCALE: NONE BIRD SCREEN GASKET LAG SCREWS CURB, FLASHING AND COUNTER 2 :LASHING, SEE 904 ROOFING BY GEN. TRADES INSULATED PREFABRICATED CURB WITH RAISED CANT, NAILER & ROOF FLANGE SEAL OPENING MOTOR OPERATED DAMPER 12" M LOUVER HOUSE (RELIEF HOOD) INSULATED PREFABRICATED CURB WITH RAISED CANT, NAILER AND ROOF FLANGE MOTOR OPERATED DAMPER REFRIGERANT LIQUID AND PUMPED �"'-"� CONDENSATE SUCTION LINES TO DRAIN LINE REVIEWED FOR BRANCH CONTROLLER —� CODE COMPLIANCE APPROVED �.�•����� SEP 10 2019 BACK City of Tukwila BUILDING DIVISION VRF UNIT, WALL MOUNTED FRONT 1Y4" CONDENSATE TERMINATE AT FUNNEL COORDINATE ELEVATION DRAIN OR NEAREST ABOVE FINISHED FLOOR SINK TAILPIECE. WITH ARCHITECT 8 M904 WALL MOUNTED VRF UNIT (IDU) DETAIL SCALE: NONE Rev Date Issue Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GREENBUSCH GROUP, INC 4 UUSIICN. MW / 1.0 6 MECWWIGL ENOINf£PoNG ( )-3 8-0569 SN M yAfE 201 BBti1tE WA .110 (208) 3'18-D889 (20.) ve-ow — RECEWED CITY OF 11, KWILA AUG 20 2019 Issue PERMIT CENTER ( Date Sheet Title Sheet Mechanical Permit Set LJJ 8/09/2019 MECHANICAL DETAILS LU M904 3: DISCHARGE DISCHARGE AIR AIR � INTAKE AIR INTAKE AIR (-� ODU-V I ( ODU-V l J PROVIDE UNIT CLEARANCES AND MOUNT PER MANUFACTURER'S WRITTEN INSTRUCTIONS —A VRF OUTDOOR UNIT DETAIL SCALE: NONE NOT USED IRS & RL, MAKE FLEXIBLE BY SECURING WITH PIPE CLAMP OVER INSULATION ANTI -VIBRATION PAD WITH STEEL PLATE AND FRICTION PAD, MASON INDUSTRIES MBSW OR ACCEPTED EQUAL SLEEPERS, MOP OR ROOF INTO MEMBRANE. SECURE TO STRUCTURE BELOW. PROVIDE METAL FLASHING CAPS. COORDINATE FLASHING DETAILS WITH ARCHITECT PROVIDE 20 GAUGE SHEETMETAL VANDAL RESISTANT COVER FOR ABOVE GROUND IRS & RL �_RS & TO BRANCH CONTROLLER -- — PUMPED REFRIGERANT LIQUID �- CONDENSATE AND SUCTION LINES DRAIN LINE, TO ODU TERMINATE OVER CONDENSATE BACK GRAVITY DRAIN CONDENSATE AC INDOOR UNIT, TERMINATE AT FUNNEL TERMINATE WALL MOUNTED DRAIN PER PLANS FRONT AC INDOOR UNIT DETAIL SCALE: NONE SECURE TO STRUCTURE , Tl HEAT RECOVERY VENTILATOR DETAIL ACCESS PANEL SCALE: NONE M905 SCALE: NONE - INSULATED MAIN INSULATED SHEET SUPPLY DUCT METAL DUCT INSULATED FLEX DUCT 3 DETAIL NOTES: 2 4 SQUARE -TO -ROUND TRANSITION d I/ ACCESSORY WHERE USED. 5 D2 , COMPRESSION STRAP ON FLEX DUCT TO INSURE AIRTIGHT JOINT. 13 } VOLUME DAMPER OUT OF MAIN 2 7JCEILING SUPPLY DUCT._..__.._..,...._..DIS SUPPLY DUCT SIZE TO�������DIFFUSER. MIN 1.5 X 'D" STRAIGHT LENGTH, IF SPACE IS AVAILABLE 5�INSULATED FLEX DUCT, MAX LENGTH OF FLEX DUCT TO BE 5FEET, SEE GENERAL NOTES.DIFFUSER NOT USED SCALE: NONE CEILING DIFFUSER DETAIL SCALE: NONE AIR NOTES: 1. PROVIDE UNIT CLEARANCES PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS 2. DO NOT DAMAGE EXISTING STRUCTURE WHEN INSTALLING. AC OUTDOOR UNIT DETAIL SCALE: NONE STRUT FOR FAN CONTRACTOR. C, WITH STRUCTUR) PROVIDE EXTENE SEE MANUFACTU CEILING FAN DETAIL SCALE: NONE V UIN IN LU I OVER THE COMPRES AIR MAIN DROP TO CONNECT AIR DISCHARGE FAN ELECTRICAL TERMINAL BLOCK TRANSPORTING HANDLE PROVIDE 20 GAUGE SHEETMETAL VANDAL RESISTANT COVER OVER ABOVE GROUND IRS & RL IRS & RL, MAKE FLEXIBLE BY SECURING WITH PIPE CLAMP OVER INSULATION IRS & RL TO BUILDING, CORE DRILL AS REQUIRED. FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING REFRIGERATION PIPING. ;ANOPY, STRUCTURE BEAM INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. COORDINATE INSTALLATION HEIGHT AFF WITH ARCHITECT NOTES: PROVIDE ATTACHMENTS PER SEISMIC ZONE 3 REQUIREMENTS. REVIEWED FOR CODE COMPLIANCE APPROVED 3EP 10 2019 City of Tukwila BUILDING DIVISION PECEIVED CITY OF fUKrWLA, AUG 20 2019 PERMIT CENTER AIR CONNECTOR (AIR CHUCK) TO AIR DEVICE/ TOOL CONNECTOR. COORDINATE' HEIGHT AFF WITH ARCHITECT Rev Date Issue I Tukwila Fire Station 52 Project No. 17012 Designed by JWG Drawn by JEA Checked by JWG THE GRBENEUSCH GROUP, INC A0005 "M MDEO @ MEGiPNM% ENG�NEERINC 18W — MCI(EASO 32 SIIItE 2 SFAiREr WA 9811E (208) 378-0569 (206) 378-0811 FAX Issue Mechanical Permit Set Date 8/09/2019 Sheet Title MECHANICAL DETAILS Sheet M905 Ln Ce W z V (n w 0 z Q m -I' V) V F_ S V Q , J I ow