Loading...
HomeMy WebLinkAboutPermit M19-0147 - EDGECONNEX - COOLING AND ROOFTOP UNITSEDGECONNEX 3425 S 116TH ST BLDG 6 M19-0147 0 Parcel No: Address: �~^�xx "�� Tukwila ~~U~� v�n o K�r*m�Uoa Department mfCommunity Development 638OSnu,hcenterBoulevard, Suite #1OU Tukwila, Washington 9O18B Phone: 206'431'3670 Inspection Request Line: ZV6-438'g35U Web site; http://www.TukwilaWA.gov 1023049043 3425SI16THSTBLDG6 Project Name: EDGECONNEX MECHANICAL PERMIT Permit Number: K419'0147 Issue Date: 9/19/2019 Permit Expires On: 3/17/2020 Owner: Name: Contact Person: Address: Contractor: Name: Address; POBOX 49OO'5CDTT5DAUE,WA, 85261 M|[HAELM[UERM0T 5006THIRD AVE S,6EATTLE,WA, g8I]4 KxCK|NSTRY[OLLC(OONSTRUCTION) POBOX Z4507'SEAlTLE,WA, 98134 License No: MCKINCL942DW Lender; Name: ''^ Phone: C206 83I-8147 Phone; (2U6)762-3]-1l Expiration Date: 3/16/2020 DESCRIPTION QFWORK: (4) NEW COOLING UNITS AND (8) ROOFTOP UNITS WITH ASSOCIATED PIPING Valuation of Work: $257,000.00 Type ofWork: REPLACEMENT Fuel type; ELECT Fees Collected: $3,282.67 Electrical Service Provided by: 5EATTLECITY LIGHT Water District: TUKYV|LA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical [ode Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WACities Electrical Code: vVACZ90'46D: VVAState Energy Code: 2017 2017 2017 2015 pcmit Center Authorized Slgnatue: Dxte: ?// �//� I hearby certify that I have read and examined this permit and know the same to be true and correct, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state urlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and agree tothe conditions attached Lothis permit. ` ��_/�_�� Signature: lu��~ -�� ~ Date: ' � � /� Ph��L� Print ��/^�«`' /�r7- �^n t= This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended nrabandoned for vperiod nfl8Odays from the last inspection. PERMIT CONDITIONS: l: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2; All permits, inspection record card and approved construction documents shall hekept at the site ufwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the buil,ding inspector based onsatisfactory completion mfthis requirement, S: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City nfTukwila Building Department (ZU6431-3G7O). 6: All electrical work shall beinspected and approved under a separate permit issued bythe City ofTukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila, Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not hevalid. The issuance ofapermit based owconstruction documents and other data shall not prevent the Building Official from requiring the correction nferrors |n the construction documents and other data. 8: *~~x8E[HAN|[ALPERMIT O}mDnOONS*~* 5, All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431'367O). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices, These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 13: H.V.4I. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall heequipped with vnautomatic shutoff. Automatic shutoff shall be accomplished hyinterrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (|M[6U6.l'6O6Il} 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 15: Duct detectors shall send asupervisory signal only upon activation. (City Ordinance #24]7) CITY OF TUKWILO Community Development Department Permit Center 6300 Sauthcenter Blvd., Suite 100 Tukwila, WA 98188 http;//www.TukwilaWA.gov Mechanical Permit No. kfit Project No. Date Application Accepted: Date Application Expires: (For office usc only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax, **please print** SITE LOCATION Site Address: Tenant Name: E,I)C7Kr.cyLi King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: D Yes PROPERTY OWNER Name: ibOefi)/A)/0/2X Address: pri) typ 4, 9F00 City: State: 7? Zip:c39_,6 CONTACT PERSON - person receiving all project communication Name: VCA NO) itir , &US Address: A n , % City: sin-ra State: baA, Zip: /09 Phone: 0 0 L .,37 vq,,,Fax: Email: . _ / _ / rri;emoltihq 6 Mr.k,kriiv ,aoh, 0 MECHANICAL CONTRACTOR INFORMATION Company Name: d A MLEWS 776/ 60 Address: s-Dac S City: 3 im, f., rit State: L'4 Zip: Phone:0th 17,, yi(17-Fax: Contr Reg No.: klawc.c.ipf2,.hap Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 7 C7-1 ereie) Describe the scope of work in detail: UY)j 0 a 8 I44-Ja Use. Residential: New EJ Replacement Commercial: New.......... Ej Replacement Fuel Type: Electric Gas Other: W.V1pplicationsWorms-Applications On Linet2016 ApplicationslMechanical Permit Application Revised I-4-16.docx Revised: January 2016 Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler * Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; Construction and property maintenance during the daytime hours (7am-10pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING ZED AGENT: Signature: Print Name: .)?) Mailing Address: 47 1o1,, w•ite-c le» Day Telephone: Date: R3Z G?cq WD3 City State D Zip H:kApplicationsWorms-Applications On Line12016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $3,282.67 M19-0147 Address: 3425 S 116TH ST BLDG 6 Apn: 1023049043 $3,282.67 Credit Card Fee $95.61 Credit Card Fee R000.369.908.00.00 0.00 $95.61 MECHANICAL $3,064.48 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $2,418.43 PLAN CHECK FEE R000.322.102.00.00 0.00 $612.90 TECHNOLOGY FEE $122.58 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18497 R000.322.900.04.00 0.00 $122.58 $3,282.67 Date Paid: Thursday, September 05, 2019 Paid By: PATRICK A ALTEBERND Pay Method: CREDIT CARD 515071 Printed: Thursday, September 05, 2019 1:17 PM 1 of 1 CSYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/05/2019 01:17:23 PM CREDIT CARD SALE VISA CARD NUMBER: **********5790 K TRAN AMOUNT: $3,282.67 APPROVAL CD: 515071 RECORD #: 000 CLERK ID: Rachelle X (CARDHOLDER'S SIGNATURE) I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy 1- ii"Orlic+1,ntrd,11-4.141.-Nr1=--rvrinf 01G/11110 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/05/2019 01:17:23 PM CREDIT CARD SALE VISA CARD NUMBER: **********5790 K TRAN AMOUNT: $3,282.67 APPROVAL CD: 515071 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://www.myvirtualmerchant.comNirtualMerchant/transaction.do?dispatchMethod—print... 9/5/2019 INSPECTION RECORD Retain a copy with permit NSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: Type of Inspection: m ; c4i J Addre,�: -- , 311 25 5 Date Called: , Special Instructions: mate Wanted: 1/ 4 [v a.m. pm. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COM ENT nspec e: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectiot. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3f 70 Proje (;litle--X Type o Ins ection: 4.-L, Address 34dis' i 4 5 f Date Called: Special instructions: a a fh irvic Date Wanted: ,.. ,�+ 1j a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. Date: / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 00. Call to schedule reinspection. /( INSPECTION RECORD Retain a copy with permit N P I0N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M/19- 0 lq7 Project: — e of ns 0 ec i • Address: LJ 3c-I2.5 5 Date Cal Pd: Special Instructions: . , LDate Wanted: a.m. P.m. Requester: 'Phone No: 2-0 ---- 22 zit, Approved per applicable codes. _COMMENTS: Corrections required prior to approval. ti5 pecto : REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro`ect; �T pe Qf Inspection:Add 11 es � � «.j.�� �'?ate Ca d. Special" nstructions: Date anted: � - p.m. Requester: �yy� �� j# Phone }i0. k l Approved per applicable codes. rrections required prior to approval. COMMENTS: V V Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 71)6'E 0:)AilUrEX Type of nspe on: 41 Address: 2-C-' 67 /' Date C lied: Speciai Instructions: Ago & Date Wanted: a.m. p.m. 'Requester: Phone No: proved per applicable des. 1 1 Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0147 DATE: 09/05/19 PROJECT NAME: EDGECONNEX SITE ADDRESS: 3425 S 116 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision II after Permit Issued DEPARTMENTS: Building Division Public Works A_Apn AkpC, 6\-1c6161 Fire Prevention 1111 Planning Division Structural Permit Coordinator 11 PRELIMINARY REVIEW: Not Applicable 7 (no approval/review required) DATE: 09/10/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 10/08/19 P1 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 12 Fire Ej Ping PW Staff Initials: 12/18/2013 MCKINSTRY CO LLC 0 Page 1 of 2 Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries [Search L&l SEARCH A-Z Index Help My L&1 Workplace Rights Trades & Licensing MCKINSTRY CO LLC Owner or tradesperson Principals ALLEN, DEAN CHARLES, PARTNER/MEMBER Hagar, Joseph Donald, PARTNER/MEMBER PEDERSEN, JAMIE D, AGENT MOORE, DOUGLAS JAMES, PARTNER/MEMBER (End: 03/01/2018) ALLEN, DAVID EDWARD, PARTNER/MEMBER (End: 03/01/2018) TEPLICKY, JOSEPH 1NILLIAM, PARTNER/MEMBER (End: 03/01/2018) Doing business as MCKINSTRY CO LLC WA UBI No, 602 569 922 PO BOX 24567 SEATTLE, WA 98134 206-762-3311 KING County Business type Limited Liability Company Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Registered training agent. Check their eligible programs and occupations. License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MCKINCL942DW Effective — expiration 03/16/2006— 03/16/2020 Bond WESTERN SURETY CO Bond account no. 929511574 Active. Meets current requirements. $12,000.00 Received by L&l Effective date 09/02/2010 09/09/2010 Expiration date Help us improve https://secure.lni.wa.goviverifv/Detail.asox?UBI=602569922&T ,IC=MC K 947 TIWk S A W= 0/1Q/1(11Q VICINITY MAP 'W MANUAL VOLUME DAMPER :D IblM#TIRIZE), VFLUME JAMPER BACKDRAFT DAMPER . . . . . . . . . . . . MITERED ELBOW WITH TURNING VANES NILANCH CONNECTION TO MAIN SUPPLY GRILLE WITH AIR QUANTITY Z100R/1OOE RETURN/EXHAUST GRILLE WITH AIR QUANTITY THERM11STAT P, TEMPERATURE/HUMIDITY SENSOR TEM?�EKATURE SENSOR MECHAWAL SYMBOLS � PC D PUMPED CONDENSATE DRAIN ,I--RHG----q REFRIGERANT HOT GAS RL REFRIGERANT LIQUID Ord PIPE UP PIPE DOWN CAP 90' ELBOW RISE OR DROP IN ELEVATION TEE OR BRANCH CONNECTION CONNECT TO EXISTING ABBREVIATIONS E - EXISTING TO REMAIN PCD PUMPED CONDENSATE DRAIN R - RELOCATE CIA OUTSIDE AIR D - DEMOLISH EA EXHAUST AIR AFF ABOVE FINISHED FLOOR RA RETURN AIR OBD OPPOSED BLADE DAMPER SA SUPPLY AIR BDD BACKDRAFT DAMPER SWR - SIDEWALL REGISTER CRAC COMP. RM. A/C UNIT LINO - UNLESS NOTED OTHERWISE RHG REFRIGERANT HOT GAS CFM - CUBIC FEET PER MINUTE RL - REFRIGERANT LIQUID OFCIRNHED, CONTRACTOR INSTALLED. OWNER FURNISHED ITEMS ARE PURCHASED AND WARRANTED SOWNER STATED IN THESE DOCUMENTS BY BURR COMPUTER ENVIRONMENTS, INC. COW9151 CON33171 CON35181 CON30152 CON34172 CON36182 REMARKS: 1 18"SUPPORT LEGS. 2. FACTORY WIRED DISCONNECT SWITCH- 3- ONE(l) REFRIGERANT RECEIVER AND BRACKET ASSEMBLY FOR EACH 3-FAN CONDENSING UNIT SECTION, 4. ALARM TERMINAL CONNECTIONS. 5. POWERED FROM ASSOCIATED CRA UNIT- 6. EXISTING CONDENSER TO BE DISCONNECTED FROM CRAD3000 CIRCUIT AND RELOCATED TO SERVE CRA15000. ECONO-PHASE REFRIG. PUMP MODULE SCHEDULE (OFCI) UNIT TAG ERP15000 ERP17000 ERP18000 ERP19000 MANUFACTURER VERTr,/ VERTrV` VERTfV VERTFV MODEL NUMBER PR125AA6DD-000O PR125AABDD-0000 PR125WDD-0000 PR125AA6DD-0000 CRAC UNIT SERVED CRA15000 CRA17000 CRA18000 CRA19000 PUMP TYPE REFRIGERANT REFRIGERANT REFRIGERANT REFRIGERANT QUANTITY OF PUMPS 2 2 2 2 HORSEPOWER 1.6 1.6 1.6 11.6 VOLTS/PHASE/HERTZ 4801360 48GI3160 480/3/60 480/3t60 FULL LOAD AMPS (FLA) 3.5 (EACH) 3.5 (EACH) 3.5 (EACH) 35 (EACH) REMARKS 1,2,3 1,2,3 1,2,3 1,2,3 1. REFER TO THE SPECIFICATIONS FOR ALL MATERIALS, MANUFACTURERS, METHODS OF CONSTRUCTION AND INSTALLATION PROCEDURES UNLESS NOTED OTHERWISE IN THIS SET OF PLANS. 2. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE AND BECOMING FAMILIAR WITH THE EXISTING BUILDING AND CONDITIONS WITHIN THE SCOPE OF THIS PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH OTHER TRADES PRIOR TO FABRICATING AND INSTALLING THE MECHANICAL SYSTEMS. 3. THE APPROXIMATE LOCATIONS OF MECHANICAL ITEMS ARE SHOWN ON THE PLANS. THESE PLANS ARE NOT INTENDED TO GIVE COMPLETE AND ACCURATE DETAILS IN REGARD TO LOCATION OF DEVICES, EQUIPMENT, ETC.. EXACT LOCATIONS SHALL BE DETERMINED BY ACTUAL MEASUREMENTS TAKEN AT THE BUILDING AND IN COORDINATION WITH EXISTING CONDITIONS AND ALL OTHER TRADES. 4. ALL WORK SHALL COMPLY WITH PERTINENT STATE AND LOCAL CODES. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES, AND INSPECTIONS. 5. WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL INCLUDE ALL LABOR AND MATERIALS ESSENTIAL TO PROVIDE COMPLETE FUNCTIONING SYSTEMS AS DESCRIBED IN THE CONTRACT DOCUMENTS. IN CASES OF DOUBT AS TO THE WORK INTENDED, OR IN THE EVENT OF NEED FOR EXPLANATION, THE CONTRACTOR SHALL REQUEST ADDITIONAL INFORMATION FROM THE ARCHITECT/ENGINEER. WORK SHALL NOT PROCEED WITHOUT CONFIRMATION BY THE ARCHITECT/ENGINEER. 6. THE CONTRACTOR IS REQUIRED TO PROVIDE SUBMITTALS FOR ALL MATERIALS AND EQUIPMENT TO BE INSTALLED WITHIN THE SCOPE OF THIS PROJECT. 7. THE CONTRACTOR SHALL WARRANT THE INSTALLATION OF THE EQUIPMENT PURCHASED BY THE OWNER FOR ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER. B. THE CONTRACTOR SHALL WARRANT THE EQUIPMENT AND INSTALLATION OF THE EQUIPMENT PURCHASED BY THE CONTRACTOR FOR ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER. 9. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 10. GRILLES, REGISTERS, AND DIFFUSERS SHALL BE AS PER THE SCHEDULE. FRAME TYPE OF EACH DEVICE SHALL BE DESIGNED FOR THE CEIUNG TYPE IN WHICH IT IS INSTALLED. 11. COORDINATE THE LOCATION OF ALL AIR DISTRIBUTION DEVICES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN, INCLUDING LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS, AND SMOKE DETECTORS. 12. MECHANICAL EQUIPMENT AND DEVICES (VALVES, DAMPERS, TERMINAL UNITS, ETC.) INSTALLED ABOVE INACCESSIBLE COUNGS SHALL HAVE ACCESS DOORS INSTALLED IN THE CEILING TO ALLOW FOR SERVICE. THE MECHANICAL CONTRACTOR SHALL FURNISH THESE ACCESS DOORS FOR THE GENERAL CONTRACTOR TO INSTALL. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF THESE DOORS WITH THE ARCHITECT TO BEST ALLOW FOR SERVICE AND ARCHITECTURAL APPEARANCE. 13. THE CONTRACTOR SHALL PROVIDE TEMPORARY FILTER MEDIA AS REQUIRED FOR THE OPERATION OF CRAC'S, RTU'S DURING CONSTRUCTION. THESE FILTERS ARE TO BE CHANGED AS NEEDED THROUGHOUT THE CONSTRUCTION PROCESS. THE UNITS SHALL NOT RUN WITHOUT THESE FILTERS INSTALLED. THE CONTRACTOR SHALL INSTALL THE FILTERS PROVIDED WITH THE UNIT PRIOR TO THE AR BALANCE OF EACH UNIT. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, 14. VERIFY LOCATION OF THERMOSTATS AND SPACE TEMPERATURE SENSORS WITH THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. INSTALL THERMOSTATS AND SENSORS AT THE SAME CENTERLINE ELEVATION AS LIGHT SWITCHES. 15. ALL MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME -SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH THE TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, ASTM E-84-91A AND ANSI/UL 723-86. 16. MECHANICAL CONTRACTOR TO PROVIDE ARSIDE TEST AND BALANCE (NEBB OR AABC) FOR ALL AFFECTED WAC SYSTEMS, INCLUDING ALL AIR DEVICES, AIR TERMINAL UNITS AND FAN COIL UNITS WITHIN THE SCOPE OF WORK. REFER TO SHEET M2.1 FOR AIR QUANTITIES. 17. MECHANICAL CONTRACTOR TO PROVIDE OPERATING AND MAINTENANCE MANUALS FOR ALL EQUIPMENT TO THE OWNER CRAC UNIT SCHEDULE (OFCI) • DELINIUMBER UNIT CONFIGURATION EAT D• B/VV13 ff) EAT 1B1VVB ff) SENSIBLE COOLING CAPACITY - KVV TOTAL COOLING CAPACITY - KW (MI3H) FACE VELOCITY (FP" FLA (FLA W1 HUM & REHEAT LOCKED OUT) M I 1. REFRIGERANT PIPING UP THROUGH 2': DRAWN TEMPER COPPER TUBING ASTM B280 TYPE "ACR" WITH WROUGHT COPPER FITTINGS (ASTM 816.22). SILVER SOLDER ALL JOINTS WITH AWS A5.8 CLASSIFICATION 8 AG-1 SILVER SOLDER. UTILIZE NITROGEN PURGE WHILE GRAZING. 2. REFRIGERANT VALVES: A) SHUT OF VALVE UP THROUGH 2": 1) STRAIGHT THROUGH BILL VALVES: VALVE RATED FOR 500 PSIG WORKING PRESSURE AND 275*F WORKING TEMPERATURE. FULL PORT, FORGED BRASS OR BRONZE BODY AND BONNET COVER, CHROME PLATED BRONZE BALL, PTFE, OR TFE SEATS, AND WITH SOLDER END CONNECTIONS. 2) PACED -ANGLE VALVES: RATED FOR 500 PSIG WORKING PRESSURE AND 275T WORKING TEMPERATURE. FORGED BRASS OR BRONZE BODY, FORGED BRASS SEAL CAPS WITH COPPER GASKET, BACK SEATING, RISING STEM AND SEAT, MOLDED STEM PACKING, AND WITH SOLDER END CONNECTIONS. B) SERVICE VALVES: RATED FOR 500 PSIG WORKING PRESSURE AND 27TF WORKING TEMPERATURE. FORGED BRASS BODY WRII COPPER STUBS, BRASS CAPS, REMOVABLE VALVE CORE AND WITH SOLDER END CONNECTIONS. 3. REFRIGERANT SPECIALTIES: A) MOISTURE/LIQUID INDICATORS: RATED FOR 500 PSIG WORKING PRESSURE AND 275*F WORKING TEMPERATURE. ALL BRASS BODY WITH REPLACEABLE, POLISHED, OPTICAL VIEWING WINDOW WITH COLOR CODED MOISTURE INDICATOR AND WITH SOLDER END CONNECTIONS. B) STRAIGHT THROUGH OR ANGLE TYPE STRAINERS; RATED FOR 500 PSIG WORKING PRESSURE AND 27FF WORKING TEMPERATURE. FORGED BRASS OR STEEL BODY WITH STAINLESS STEEL WIRE OR BRASS REINFORCED MONEL SCREEN. 80 TO 100 MESH IN LIQUID LINES UP TO 06. IN SIZE, 60 MESH FOR LARGER LIQUID LINES, AND 40 MESH IN SUCTION LINES. PROVIDE SCREWED CLEAN OUT PLUG AND SOLDER END CONNECTIONS. C) PERMANENT FILTER DRIERS: RATED FOR 350 PSIG WORKING PRESSURE AND 225T WORKING TEMPERATURE. STEEL SHELL AND WROUGHT COPPER FITTINGS FOR SOLDER END CONNECTIONS. MOLDED FELT CORE SURROUNDED 13Y DESSICANT. 4. PIPING INSULATION: A) REFRIGERANT PIPING (HOT GAS AND LIQUID FOR DATA CENTER DSE SYSTEMS): I" THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. ALUMINUM JACKET WITH PRE -MOLDED FITTINGS (OUTDOOR ONLY). B) REFRIGERANT PIPING (HOT GAS FOR UPS RM DS SYSTEMS): 1 THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. ALUMINUM JACKET WRIH PRE -MOLDED FITTINGS (OUTDOOR ONLY). C) CONDENSATE DRAIN: ) " THICK FIBERGLASS WITH ASJ. SEAL VAPOR BARRIER. PROVIDE PRE -MOLDED FITTINGS. D) CRAC AND ERP EQUIPMENT: INSULATE ALL UNINSULATED INTERNAL REFRIGERANT PIPING, FITTINGS AND REFRIGERANT PUMP WITH 1/2' THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. 5. ALL DUCTWORK SHALL BE CONSTRUCTED OF NEW LOCK FORMING QUALITY GALVANIZED SHEET METAL IN ACCORDANCE WITH THE LATEST SMACNA STANDARDS TO THE 2" W.G. PRESSURE CLASSIFICATION. ALL LONGITUDINAL SEAMS AND TRANSVERSE JOINTS SHALL BE SEALED PER SMACNA DUCT SEALING REQUIREMENTS SEAL CLASS *8*. SEAL WITH A WATER BASED ADHESIVE SEALER DESIGNED FOR MEDIUM VELOCITY DUCT SYSTEMS. SEALER SHALL BE HARDCAST, INC., "IRON GRIP WATER BASE DUCT SEALANT #601.* DUCTWORK SHALL BE HUNG AS HIGH AS POSSIBLE FROM THE BUILDING STRUCTURE WITH HANGER ASSEMBLIES IN ACCORDANCE WITH "SMACNA" REQUIREMENTS. THE CONTRACTOR SHALL PROVIDE ADDITIONAL RISES, DROPS, AND OFFSETS IN DUCTWORK AS REQUIRED. 6. ALL INSULATION SHALL HAVE A COMPOSITE (INSULATION, JACKET OR FACING, AND ADHESIVE USED TO ADHERE FACING OR JACKET TO INSULATION) FIRE AMD SMOKE HAZARD RATING (AS TESTED BY PROCEDURE ASTM E84, NFPA 225, AND UL 273) NOT EXCEEDING A FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 7. ALL EXPOSED SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL NOT BE INSULATED. ALL CONCEALED SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1 1/2- THICK DUCT WRAP, 3/4 LB/CUTT. INSULATION. INSULATION SHALL HAVE A FACTORY APPLIED FOIL-SKRIM-KRAFr FACING CONSISTING OF 0.35 MIL ALUMINUM FOIL REINFORCED WITH CLASS YARN MESH AND LAMINATED TO 40 POUND CHEMICAL TREATED, FIRE RESISTANT KRAFT. OVERLAP ALL SEAMS, STAGGER LONGITUDINAL SEAMS. SEAL SEAMS WITH 4' WIDE PRESSURE SENSITIVE TAPE AND OUTWARD CLINCHING STAPLES. USE SPEED CLIP PINS ADHERED TO DUCT SURFACES OVER 18' IN WIDTH ON 16* CENTERS AND MAX. 3" FROM INSULATION SEAMS. APPLY BRUSH ON VAPOR RETARDANT MASTIC OVER TAPE EDGES, PINS, AND TEARS IN THE FOIL VAPOR BARRIER. MINIMUM INSULATION MUST MEET IEC (R-3.3). 8. MECHANICAL CONTRACTOR TO PROVIDE 5 DAYS OF ASSISTANCE FROM STARTUP TECHNICIAN OR QUALIFIED PERSONNEL TO ASSIST COMMISSIONING AGENT DURING COMMISSIONING PERIOD. 9. MECHANICAL CONTRACTOR TO PROVIDE ROOF CURBS AND SHEET METAL HOODS FOR PIPE PENETRATIONS. GEN CONTRACTOR TO CUT ROOF, INSTALL ROOF CURBS, AND FLASH IN ROOF MEMBRANE. COORDINATE SIZE OF OPENING WITH ELECT TO INCLUDE POWER AND CONTROL CONDUITS. s'I:)Iect to errors ana j 7­?nns ACprCqj!­f,..,o,1svuction cocuments am 3i'!�T:­Me v.v;abon of any aouvired rode or )!clinance. Reoe,vi of aprgovec F.eja Coot' an(! _R"10i Fs gn- CdY Of I-UKMQI BUILDING DIVISION REVISION5 ri rne scooe Of WC I -Ijkmia Boodwq 0" . E: kevisibris wth reou;re a new oian I W�&T.Lfjili" FOR SEPARATE PERMIT REGUIRED FOR: CODE COMPLIANCE E] Mechanicwl [REVIEWED APPROVED SEP 18 2019,�' 9PIumbing ET Gas Piping City ofTukwila City of Tukwila BUILDING DIVISION I BUILDING DIVISION ngcEivp CITY OFTLIOMLA SAP 05 2019 1p PER,11T CENTER i3c­­111 BURR COMPUTER ENVIRONMENTS, INC. Lei, 1110] 1; r.r. -01 0 4 1 x cD c*j C) CD cl) 00 r LU cf) 01 cn -:t !_j 0 CD C) W cr) CD ISSUES& REVISIONS Na Date Deemipflim 17 79/04/19 ISSUE FOR PERMIT DRAWN: PJW REVIEWED: RWB PROJECT NO.: C1766.00 MO•1 PROPRIETARY: NOT FOR DISCLOSURE OR USE WITHOUT THE WRIITEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. GENERAL NOTES KEYED NOTES I REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 01 ROUTE 3/4-PCD AND (2) SETS OF 1-3/8" REFRIG HOT GAS AND (2) SETS 2 REFER TO SHEETS M7.1 AND M7.2 FOR INSTALLATION DETAILS AND OF 1-1/8" REFRIG LIQUID LINES DOWN WALL TO CONNECT TO CRAC UNIT SECTIONS. CONNECTIONS IN TOP OF UNIT. 3. ALL EQUIPMENT AND PIPING SHALL BE SEISMICALLY BRACED IN @ ROUTE REFRIG HOT GAS AND LIQUID LINES UP THROUGH ROOF PENETRATION ACCORDANCE WITH LOCAL CODES. AND ROOF HOOD TO CONDENSING UNITS ON ROOF. COORDINATE ROUTING WITH ELECT CONTRACTOR FOR CONTROL AND POWER CONDUITS. REFER TO ML.Z WK CONTINUATION, REFER TO M7.1 FOR ROOF HOOD DETAIL. (9 1 10 11 (�3) CONNECT TO EXISTING PCD 14) (15 (16) 17 T- MECHAN16AL LEGEND HOT GAS REFRIG. PIPING lit -,T GEN61000 EXI�T LIQUID LINE REFRIG. PIPING -- ---- CEW12000 kF)OOKW) (600KWV PUMPED CONDENSATE PIPING ( I I I I I i I I I ----------- --- - ------------ - - iL L _1 --- - ---------- - ---- - -------------- - ---- - I --------- - - MECHANICAL -------------- II YARD CON 14081 c:i j,", i ��f 1 122 71 F-7 i I .. i ' � 2784 SF H --------- -------- - — ----- --- ----- -------------- - - - ---------- ---- -------- ---------- - - ------ - - --- -------------- - -- ----- - ---------- O --- - -------- - — ------- ------- ------- -4- --- --- ------- ---- ------ — ------- - — - ------- ------------- — ---- -------------- -- --- ------ + 4- LOADING 9•SB (NEW) PLC DOCK MB I BA� A UP C!"00 _RA07011,0 �td i 000 ill MY) F CUT FVpNT co TT PA I �_16 . . ......... L--- 630 SF 0 FRONT DH 002 LIPD LCIC --------------- E�ECTRICAL 'RONT 'Orjr -- -­R,0-,;­T-j--------- F_( T I NT r o 1000 1000 - RM B.M HCH 7 NOT PRE- I,i0001000 PSBIOOO BATT. BAIT ! BAFT. 1000 1000 1000 100, 1 1000 124 ERONT AN L m ] I � I U MDPD MDPA ass 8 11. All �ISAIOOO TS ATSA IT-2 PCD— ------------------------- a, UPSDIOOO 9 MDSA [Do 1000 .5"PCD- 2". 1 EXIT oo BA I F. BATT, BATT. 1000 D] [A 1000 CRA2200 Cd A2000� CRA190 CRA18GOQ,0� IF 128 'CRA2 00 1 �Zj I I (DA-15 I DLI 150 (DA I Fv (DA-1K0 STAGE SEC -EA= 2"PCD AJ PIDUC100, I'DUS1000 PDU 10,00 DOO - - - - - - - - A 2"PCD PDUDIOOO 15000 17000 102 i mnrl --------------- - 283151- ------------ U . J ..... -C 2 Z� �2 jlon000 BMID FA.. STORAGE )00 02 UO 12 �1] EPO 2 OG_ — - - ---------- E� — - - - --- - ------ T y FE v Up �MECH 5 F 4 122 X y F/ 4,J/V FE c 11 10 0 'OT N 0 T-7 D DATA HALL 2 1 66 teg ANITOR MENS I LCP r 1 2000 W /7' IZ TRNC 0 j 129 F 1-31 7 2000 L, D p 200 I Lj I p TRNO MBC PINEIN) 4—��)- I —Y_ /� I � _ _ _ � AdiTh �IIBATT wllil ��IATT IS _j 1001 PC[ -IF p IIAA231�1 --- (D , , I E, 111112000] 0 E_ A�, IMUO 77- F7 BREAKOUT Cu 0 133 IFE -- -- --- Ld —1 T CRT000 A17000 A15000 r"7FL7,TCRZ12000 r F,7 UT. CR) (DA-150) E Tffgo(DA-150) RDA 150) F 7',03)000-7 E 0 r FLIT. / Z /i/ r� FLIT C_R 176000 1 I r)(DA-150) X(D A ­1 A(DA 150) RDA-150) 177 _�32 -SECURlITY— — - 134 — — ___ — — —2'P ­j __j 1 2 PCD 1.25 KD u — LL 2 �3 L 11 - - - ----------- - ------- -------- - - ------------- ------------- J Il IN MICHAWAL PV4W PLAN Ak SCALE- vs%v-d- 7r REVIEWED FOR CODE COMPLIANCE APPROVED SEP 19 2019 I City of Tukwila BUILDING DIVISION nECEIVEI-) CITY OF -1-C.I.VNILA SEP 0 5 2019 PERMIT CENTER MEMO 10400 Rodgers Road Ph: 281-374-8644 HOUSTON, TEXAS 77070 Fax 281-374-8992 N.. X CiD CD _j -� C—D CD < Uj Uv cm 0 3 Ilse 3: 73 < LU — -<f cn W 9 LU U') 11Z3_ C-3 LU E: cn ISSUES &REVISIONS Na Date- D-cflptim 1 F9/04/7191 ISSUE FOR PERMIT IN 04FE, 40 1 IL'_ 40 DRAWN: PJW REVIEWED: RWB PROJECT NO.: C1766.00 M2.1 NOT FORDISCLOSUREOR USE WITHOUT THE CONSEM OF BURR COMPUTER EWRONMENTS, INC. GENEPAL NOTES 1. REFER TO MO.1 FOR SPECIFICATIONS, SYMBOLS, AND LEGENDS. 2. COORDINATE ALL ROOF PENETRATIONS WITH STRUCTURAL ENGINEER AND BASE BUILDING WARRANTIED ROOFING SUBCONTRACTOR. 3. ALL REFRIGERANT PIPING SHALL BE INSULATED AND WITH ALUMINUM MECHANICAL LEGEND LIQUID LINE REFRIG. PIPING KEYED NOTES MECH CONTRACTOR TO RELOCATE CONDENSERS CURRENTLY SERVING CRA03000 TO LOCATION SHOWN. PROVIDE NEW LABELS TO MATCH EQUIPMENT IDENTIFICATION ON PLAN. ROUTE INSULATED REFRIGERANT HOT GAS AND LIQUID PIPING DOWN THROUGH ROOF PENETRATION AND ROOF HOOD. REFER TO M2.1 FOR CONTINUATION. CONNECT REFRIGERANT HOT GAS AND LIQUID PIPING TO CONDENSING UNIT AND REFRIGERANT RECEIVER CONNECTIONS. REFER TO MANUFACTURER PIPING SCHEMATIC AND INSTALLATION INSTRUCTIONS. ROUTE REFRIGERANT PIPING ON DURA-BLOK MODEL DB630 ROOFTOP PIPE SUPPORT. REFER TO SPECIFICATIONS FOR SPACING. CONNECT EXISTING REFRIGERANT HOT GAS AND LIQUID PIPING TO CONDENSING UNIT AND REFRIGERANT RECEIVER CONNECTIONS. REFER TO MANUFACTURER PIPING SCHEMATIC AND INSTALLATION INSTRUCTIONS. INSTALL OIFCI LIEBERT MICRO -CHANNEL CONDENSING UNIT ON OFCI LEG STANDS. CONTRACTOR SHALL COORDINATE HEIGHT OF STANDS PRIOR TO ROUGH -IN. CONDENSING UNITS TO BE LOCATED ON EXISTING SUPPORT CURBS PREVIOUSLY PERMITTED UNDER D16-0253 AND D14-0059. - - - ------------ - - - ---------------- -- - - - - - -------------- ------- ------------- ----------- OPENING �LX�)CON43221 03 CON351 81 t — - — - — - — - — - � ;06 02 ub 5-1 1400 0 04 31 OPENING (EX)CON 10052 Mail RmtF Rg C IFOof CON331711 OPENING ------------ '__'_�' LuT lumnlLul �~EXF— |01 | | | 7 � . . '--�--'--' ----|'--------'PUT CON2211,tROOF N32051 f*|—'--' �-- '-----'—�---'--- '-----'—_- |'__'__-__'_]�|___________ ROOF' 0 | | 0�| �� | | �� | ��| 4 /REVIEWED FOR CODE COMPLIANCE APPROVED City of TukvAlaSCALE- 1/8'-1'-0' BUILDING DIVISION ' CID cf) op CDLLI ISSUES &REVISIONS Descriptim ____1FlSSUE FOR PERMIT DRAWN: PJW REVIEWED: RW8 PROJECT NO.: C1766.00 M2.2 -AWCNOT FOR DISCLOSURE OR USE WITHOUT THE WRITTEN URR COMPUTER ENVIRONMENTS, INC. GENERAL NOTES KEYED NOTES 1. REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 01 CONNECT SUPPLY AIR PLENUM TO TWO(2) 56x24 FRAMED SUPPLY AIR OPENINGS BELOW RAISED FLOOR BY OTHERS. PROVIDE AND INSTALL SHEET 2. REFER TO SHEET M7.2 FOR DETAILS AND SECTIONS. METAL BLANK OFF PANEL AT ALL FUTURE CRAC OPENINGS. COORDINATE 3. ALL ROOF PENETRATIONS SHALL BE COORDINATED WITH STRUCT. ENG. ALL LOCATIONS OF NEW AND FUTURE CRAC SUPPLY AIR OPENINGS WITH GEN. ROOF WORK TO BE DONE BY CC WITH WARRANTED ROOFING SUBCONTRACTOR. CONT. REFER TO DETAIL 03/M7.2. 4. ALL DUCTWORK IS EXISTING UNLESS SHOWN OTHERWISE ON PLAN. 02 PROVIDE AND INSTALL INSULATED SHEET METAL PLENUM WRAPPED AROUND FLOOR STAND AS SHOWN ON DETAIL 03/M7.2. 03 MECH CONTRACTOR TO PROVIDE 80 FLOOR SUPPLY GRILLES IN THIS ROOM. n7) LET SIZING CRA RT ROUND NECK SIZE k17 T-, E E.;ST, QEN01000 EXIST, GFN 0 0 0 f6uO K i0) 6-0()Kvv ------- 0 mc --- — - - ------- -- --------- - ------ - --T I I - 1 200 ��i 00 1 1 1 20g C D,4 1414 1404 1 T FCUO3000 -CPD I 225 fi� I I , L i T3150 FRONT F 0 31 250 3 12x12 315�U<S) j1 X5 ---j- --1-- 000 1= � -Lw- aNi 1 7 1000 T FCU03000 ELECTRICAL ------ \1414 �1 FF - - ---------- - I i . TRND I ADSC mDSB \2:!J600 — ------ 8 BFP MDPC ATS' DPB I i 1000 i 000 1000 1000 t PRE -ACTION 42x2O ,F] BATT is 00 12x6 MECH 7 3150 1000; '0 1000 NO 7F 2Qx20 i; FRONT FIR NT I MDPA R M SD IS CRA2 1000 C A20000 CRA19000 CRA18000 IT-- �+C2000 A-150) (DA-150) �7�00 POU02000 j(DA I I 200 1 116 1 FD 124 AN 1 50 ATSD 1 T i BATT -r.,pD i M-USD DSA VID I i ATSA H, 01 1000 0 F)p TT. 1000 i0oo \EXIT UpscrIoLno BA 100 1000 0--0 89 SF --------- �jl SA IT - _j GATT ITT U�,Al I EXRAO0 I HI L 1414 CRA22000 tM CRA2300� TYP •2) -1,)0,) 1 (UA-IOU (DA-150) 81i - ` 3150 — - ----------------------- 1 B /1 120 (3 10`0 102000 12x8 SEC 200 SF 02000 =Am m m Bmp 03000 STORAGE FAC 102000 Epi) j 12x6 200T -4 ---- -- ----- 4200 L f UP b FE MECH5 122 12x8ll 400 T 1414 (TYP 2) FE c I I L--J X 0 DATA HALL 2 --------------- LCP JANITOR WOMENS MENS 2000 129 130 1 13-1 2TRNC 000 LCPD 2000 B1 I TRIND U055000 1414 2000 vi r -1 so !if i J B 1[ 000 75 B 00 I0x1O 1000 01 01 1000 19 HE --------- - ---------- 'ci T— --- -------- -------------- T- ---- ----- -- - ----- r - - - - - - r - 77 7,,. 7,7j,7- T91 4j7j.;7 ':PAi-00 CRA17000 CRA15000 7 OT I I wo F IFFUSW�� (DA-150) (DA-150) A - 1 �710 I A- �,,f) j I L I 'F A--! 50) T5 - - - - - - - - --- INCE SECUR--i_N- CO - - - MEG' L. - 12511 711 - ------------ ----- ------- 123 132 -134 25 iiiiiiiii�ilillill MEN W1 ZT ATI ATS 1500017000 . . . . . . . . . . . . . . — - — - — - — - — - — REVIEWED FOR CODE COMPLIANCE APPROVED SEP 18 2019 City of Tukwila BUILDING DIVISION tiECEiVEO CITY Cr I L Kl.ILA SEP 0 5 2019 PERMIT CENTER 10400 Rodgers Road Ph: 281-374-8644 92 HOUSTON, TEXAS 77070 Fax 281-374-89 L) J CX D C-4 j CD —j < C-D F- -00 F- — CD .< cf) 00 Cy) 0 C5 :1z LU ca CnU-) __j CDU-111 U-11 11-- co WLMS & REVISIONS No- Date Description 1 T9104119 11 ISSUE FOR PERMIT DRAWN: PJW REVIEWED: RWB PROJECT NO.:: C1766,00 M3.1 PROPRIETARY� NOT FOR DISCLOSURE OR USE WITHOUT THE WRETTE CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. r NVIRONMENTS, x C'4 j CD _j < C—D -00 cl) 00 co 3: < 4= Lu cf) <�- L0 i c*4 ICT CD cr) Lu cf) SLEEVE SECURE TOP TO ROOF JACK WITH GASKETED FASTENERS AT EACH CORNER AND 12" CENTERS. 45' INSULATED ROOF CURB ESCUTHCEON PLATE. FABRICATE IN HALVES. DEMISING WALL SHOULDER BOLT .SIDE VIEW OVERLAP TOP AND BoTrom HALVES 1'. CAULK OR RATED PARTITION—, SEAM AND JOIN HALVES WITH SHEETMETAL FILL VOID WITH APPROVED REMOVABLE DOUBLE WALL INSULATED SREWS LOCATE TOP HALF ON OUTSIDE TO SHEETMETAL NON-COMBUSTIBLE MATERIAL (ROCK REFRIGERANT PIPE TOP. SLOPE TO SHED WATER, TURN 1- SHED WATER. FILL VOID BETWEEN PIPES WITH WOOL INSULATION). AT RATED GASKET AROUND FULL FLANGE DOWN. SECURE TOP TO ROOF JACK WITH GASKETED CLOSED -CELL INSULATION. CAULK OUTSIDE OF /—PARTITIONS, SEAL BOTH ENDS OF PIPE INSULATION PERIMETER OF HOOD OPENING FASTENERS AT EACH CORNER AND 12" CENTERS WITH PIPING VOIDS WITH SILICONE CAULKING. OPENING WITH APPROVED FIRE -CAULK ANGLE BRACKET SECURED TO BOTT. SIDE OF TOP. PINS11T11 ROOF INSULATION WITH JACKET CLAMP-\ CUSHION REFRIGERANT PIPE (TYP.) UNISTRUT SECURE ROOF JACK TO CURB WITH GASKETED ELEC CONDUIT (TYP.) FASTENERS 2" IN FROM EACH CORNER AND ON -ICPIPING 12* CENTERS. SEAL ALL CORNERS AND SEAMS. SEALANT (TYP.) ESCUTCHEON PLATE ON P�IPES "" 'Tj�ej�"� P 2' MIN. THICK INSULATION BOARD SECURED EXPOSED WITHIN ROOMS ROOF, TO WALLS OF ROOF PENETRATION -ESCUTCHEON PLATE, REFRIG PIPING CONDUIT INSULATED ROOF CURB VDURA-BLOK MODEL DB6 ROOF PIPE SUPPORT WITH COORDINATE LENGTH OF SUPPORT WITH REFRIG PIPING METAL ROOF DECK 12" MIN. ROOF INSULATION AND ELECT CONDUIT REQUIREMENTS. 2X6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE; OVERALL THICKNESS TO MATCH INSULATION HOLES CUT THROUGH ROOF INSULATION AND INSULATE CONDUITS MIN. ROOF DECK TO ROUTE PIPING AND CONDUITS. 12' BELOW ROOF DECK NOTES: MIN. 3" BETWEEN HOLES IN ANY DIRECTION. 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 2) SPACING OF SUPPORTS PER SPECIFICATIONS. SUPPORT SPACING SHALL BE BASED ON THE SMALLEST DIAMETER PIPE SUPPORTED BY THE RACK. M*'� REFRIGERANT PIPE PENETRATION THROUGH ROOF. PIPING AT INTERIOR WALL. ROOF PIPE SUPPORT NOT TO SCALE NOT TO SCALE NOT TO SCALE ,—STAINLESS STEEL ENCLOSURE WITH REMOVABLE TOP. CROSSBREAK OR SLOPE FOR DRAINAGE. SPLIT RING CLEVIS TYPE TYPE HANGER INSTALL I" FOAM BOARD HANGER INSULATION TIGHT TO INSIDE WALLS OF ROOF 010 PENETRATION HANGER ROD AS REQUIRED PREFORMED THERMOPLASTIC PIPE SADDLE SPACING OF HANGERS WITH GALVA IZED CLAMP SIZED TO MATCH PER SPECIFICATIONS S2 STAINLESS STEEL COLLAR SHOULDER BOLT PIPE SIZE. NLO-SHURE OR EQUAL. THREADED ROD TURNBUCKLE SLOPE PIPES DOWN AND AS REV AWAY FROM HOOD REFRIGERANT PIPE PIPING 1140 i ! REMOVABLE STAINLESS PIPE INSULATION STEEL COUNTER -FLASHING CLAMP /— 0( 1 6 6 ADHERED MEMBRANE FLASHING FLOOR m WELDED SEAM u I \--INSULATION L6P 18 GA. GALV. MIN. 4" CLEARANCE VUNISTRUT SHEETMETAL SADDLE P SEALANT (IF REQUIRED FOR CUT HANGER ROD FLUSH MINIMUM 8" LONG FROM PIPE TO T OF CURB; MIN. 21f UNISTRUT BOLT UNISTRUT TO FLOOR. BETWEEN PIPES SHIM UNDERSIDE AS WITH BOTTOM NUT. PROVIDE FULL CIRCUMFERENCE THE SPECIFIC SYSTEM) REQUIRED 10 KEEP LEVEL GASKETED FASTENERS 12" LONG SECTION SHEET -METAL (MINIMUM 2 PER SIDE) OF HIGH COMPRESSION FLASHING RECEIVER STRENGTH CLOSED -CELL BONDING ADHESIVE INSULATION AT EACH 2x6 MIN. WOOD NAILER NOTES: HANGER POINT REVIEWED OR To SUBSTRATE; TE; SEAM PLATES AND 1) THIS DETAIL APPLIES TO INSULATED AND UNINSULATED COPPER PIPING. REFER TO CODE COMPLIANCE OVERALL THICKNESS TO FASTENERS SPECIFICATIONS FOR INSULATION REQUIREMENTS. NOTES: -p, APPROVED MATCH INSULATION 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. COVER BOARD AND 2) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 2) MAXIMUM ALLOWABLE SPACING OF HANGERS: SINGLE -PLY ROOF THERMAL INSULATION STEEL PIPE: )6" TO 0¢ * - 7'-0" O.C. SEP 18 23pp 19 MEMBRANE 3) MAXIMUM ALLOWABLE SPACING OF HANGERS (HANGER SPACING SHALL BE BASED ON 2" TO 2�" - 10'-0* D.C. ROOF DECK NOTES: THE SMALLEST DIAMETER PIPE SUPPORTED BY THE RACK): COPPER PIPE: TO 14" - 5'-0" O.C. City of Tu . la 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. COPPER PIPE: X" TO lY4' - 5'-0" D.C. 2' TO 21�" - 8'-0" O.C. BUILDING DINISION 2) SPACING OF SUPPORTS PER SPECIFICATIONS. SUPPORT SPACING SHALL BE BASED 2" TO X - 8'-0" D.C. CAST IRON PIPE: ALL - 10'-0" D.C. ON THE SMALLEST DIAMETER PIPE SUPPORTED BY THE RACK. 4) PROVIDE HANGER AT ALL CHANGES OF DIRECTION. 3) PROVIDE HANGER AT ALL CHANGES OF DIRECTION. ne%ruff MNIETRATKA PAIElFrov"Ww"E.-RANT MULTRLE rr_�wlw_ KAMKIWER af� III F_'Pwlm HANCIER PECEAIE. %IPWVMR*. NOT TO SCALE NOT TO SCALE NOT TO SCALE cl n. OF YL V VILA -NOT TO SCALE I r�ft SEP 0 5 N 9 PERMIT CENTER co ISSUES &REVISIONS scription Date • DRAWN: PJW REVIEWED: RWB PROJECT NO.: C1766.00 WRITTEN _ OF BURR COMPUTER ENVIRONMENTS, INC. �.� PROPRIETARY NOT FOR DISCLOSURE OR USE wIT40ur THE CONSENT — — — — — — — — — — — --- — — — — — - - - - -&. Ramaidilft-10"Mommi ' . TWO TIERED UNISTRUT REFRIGERANT PIPING I'll"Z"'SUPPORIT' WA � HUM PIPING PCD PIPING �UGHT FIXTURE *"-��� OFCI FILTER ASSEMBLY. FILTERS REMOVED THROUGH FRONT OF PLENUM. MECHANICAL CORRIDOR ,—EC FANS TO REMAIN IN THEIR S IPPED POSITION INSIDE UNIT. PROGRAM FANS TO ROTATE UPON S UTDOWN TO PREVENT BACKDRAF7. INSULATED SHEEr MErAL PLENUM WRAPPED AROUND FLOOR STAND. " 11' I�Osa�' '--_' --- -- - - ---�--�- 1 II,/Iw%%%t►%.i�'I 1 1/• A # ELEVATION OF BOTTOM OF OFCI UEBERT DSE REFRIG RECEIVERS MUST BE LOCATED ABOVE BOTTOM OF ECONOPHASE PUMP BOX. AIR-COOLED 0. 0. AIR-COOLED CONDENSER CONDENSER (OUTDOORS) (OUTDOORS) TRAP AT BASE SLOPE ALL HORIZONTAL PIPING BETWEEN TRAP AT BASE IF RISER IS IF RISER IS _// LIQUID RECEIVER AND PUMP AT 2' PER 10' OVER 5'-0".--,/ OVER 5'-0". LINE (2) TOWARDS THE REFRIGERANT PUMP. — FOR RISERS OVER 25', TRAP EVERY 20' OR EVENLY DIVIDED. CONTROL WIRING IN CONDUIT BY ELECT CONT. HOT GAS REFER TO ELECT DWGS. LINE (2) PROVIDE REFRIGERANT SHUT OFF VALVES PROVIDE DIFFERENTIAL CHECK VALVES ON 3/8' BYPASS LINES AT't LIQUID LINE SHUTOFFS r OFCI UEBERT OSE RECEIVER SLOPE HORIZONTAL HOT GAS PIPING DOWN 1/2- PER 10' fr TO MATCH DIRECTION OF FLOW. ECONOMIZER REFRIGERANT PUMP ROOF PIPING PENETRATION. CURB AND HOOD PROVIDED BY MECH CONT AND P INSTALLED BY GEN CONT. PIPING­SUPPORTS(TYP.) TWO(2) sErs OF REFRIG PIPING CIRCUITS. SUPPORTS (TYP) REFER TO MANUFACTURER AND DRAWINGS FOR QUANTITIES, SIZES, APPURTENANCES, AND ROUTING DETAILS. \-SLOPE HORIZONTAL HOT TRAP AT BASE GAS PIPING DOWN 1/2' PER 10 IF RISER IS OVER TO MATCH DIRECTION OF FLOW. 5 -0.. RETURN AIR FILTERS CONTROL PANEL CRAC UNIT (INDOOR) SMOKE DETECTOR COOLING C I ---CONDENSATE DRAIN PAN CONDENSATE PUMP C_+_ COMP. P VMOUNT MOISTURE DETECTION MODULE. Mi DETECTOR FURNISHED (2) COMP. WITH UNIT. (2) -1 4 T RAISED FLOOR TRAP AT BASE MOUNT CRAC UNIT ON OF RISERS OVER SUPPORT STAND' STAND FURNISHED WITHUNIT FLOOR SLAB REVIEV Factory provided internal controls shall control the CRAC and ACC functions to maintain space humidity and temperature set -points and cycle econo-phase CODE CO ED FOR APLIANCE refrigerant pumping sequence. APPS OVED 1) The internal fan operates continuously. The compressor unloads and cycles on/off as needed to maintain the set -point. The condensing unit fans speed 1 Se - 8 2019 up/down and cycle on/off as controlled by the CRAC control panel. 2) The unit mounted smoke detector shall, upon sensing smoke, shut down the unit and notify the building fire alarm system. The CRAC will restart after the City of TukvAla smoke detector has been manually reset. LRUILDING 3) The leak detection system shall, upon sensing moisture, alarm at the unit control panel and shut the unit off. DIVISION j PECE IVED DIX SYSTIE&PASS RAC %4j10EW_%"Wd%.PWW_Of CITY OF ri WE - C 'L"aWILA Im SEP �.2 OVIERATK)"N AND ROE F Ry"FG]NIER ANT- PV*G DETAL 5 2019 CENTER NOT TO SCALE I A I Am-meP 10400 Rodgers Road Ph: 281-374-8644 92 HOUSTON, TEXAS 77070 Fax 281-374-89 �j 01 X CD j CD _j < C—D < -00 CDcr) 00 CY) C:) se < LU! (—f) L0 _j LU C'i 3: co LU 1-- Cl) ISSUES &REVISIONS Na IF—D.W -1 Description :11 9/04/19 ISSUE FOR PERMIT DRAWN: PJW REVIEWED: RWB PROJECT NOC1766.00 M7.2 PROPRIETARY NOT FOR DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC.