Permit M19-0154 - COSTCO / BAKERY REMODEL - CUT AND CAP, DUCTWORK, NEW INLINE TRANSFER FANS, OVENS ETC
COSTCO -BAKERY REMODEL 400 COSTCO DR 150 AP N : 2523049063 EXPIRED 05/03/2021 M19-0154 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httn://www.TukwilaWA.gov 2523049063 400 COSTCO DR 150 MECHANICAL PERMIT Project Name: COSTCO - BAKERY REMODEL Permit Number: M19-0154 Issue Date: 5/7/2020 Permit Expires On: 11/3/2020 Owner: Name: Address: COSTCO WHOLESALE CORPORATIO 999 LAKE DR PROPERTY TAX DEPT 006, ISSAQUAH, WA, 98027 Contact Person: Name: DEE MARTINEZ Address: 1101 2ND AVE SUITE 100 , SEATTLE, WA, 98101 Contractor: Name: JACKSON DEAN CONSTRUCTION Address: 19835 SE 248 ST, MAPLE VALLEY, WA, 98038 License No: JACKSDC962QR Lender: Name: Address: Phone: (206) 962-6830 Phone: (206) 832-2900 Expiration Date: 1/8/2021 DESCRIPTION OF WORK: BAKERY REMODEL INVOLVES CUT & CAP, MODIFICATION TO EXISTING DUCTWORK. INSTALL NEW INLINE TRANSFER FANS & DUCTWORK, DEMO AND REPLACE EXHAUST FANS ON ROOF, NEW OVENS, DUCTWORK AND HOODS. Valuation of Work: $30,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $615.18 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: I hearby certify that I haO read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority toviolate mcancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree tuthe conditions attached tothis permit, Print Name: This permit shall become null and void ifthe work isnot commenced within 18Udays for the date ofissuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code, 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, s6-ptic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based unsatisfactory completion ofthis requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (ZU6'431'3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance orgranting ofapermit shall not beconstrued to6eapermit for, oran approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not hevalid. The issuance ufapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction nferrors in the construction documents and other data. 8: `MECHANICAL PERMIT CONDITIONS' 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (I06/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: Sprinklers shall beinstalled under fixed obstructions over 4feet (1.3m)wide, (NFPA1]'8.6.53.3) 14: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall bedone inaccordance with applicable standards. (|F[9Vl4) ll: All new sprinkler systems and all modifications toexisting sprinkler systems shall have fire department review and approval nfdrawings prior toinstallation cxmodification. New sprinkler systems and all modifications tnsprinkler systems involving more than SOheads shall have the written approval nfFactory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior tosubmittal tothe Tukwila Fire Prevention Bureau, Nosprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 16: Maintain fire alarm system audible/visual notification. Addition/relocation ofwalls orpartitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov q— 1P-1 Mechanical Permit No. VI, ( Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 252304 Site Address: 400 Costco Drive, Tukwila, WA 98188 Suite Number: Floor: 1 Tenant Name: Costco Wholesale New Tenant: D Yes RI ..No PROPERTY OWNER Name: Costco Wholesale Address: 400 Costco Drive City: Tukwila State: WA Zip: 98188 CONTACT PERSON - person receiving all project communication Name: Melissa Lorenc, MG2 Address: 1101 Second Ave, Ste 100 City: Seattle State: WA Zip: 98101 Phone: (206) 962-6505 Fax: Email: tnelissa.lorenc@mg2.com MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ SC-C. Describe the scope of work in detail: cli /zit 9 aC4471 A ..ei ar7"..-,i 7c, C*4 t f7C-c, igArt-6•7 Afro-w06i..-; Xrw 1,.74. KI' C 4 Vi,c7c- Re.C1 "Z-4-7,3fr.- 01 0016-1.../ -Z.,4-,..4 7/t4 -J fe- e FPI ''''S. A,6••••• tbst ii4,weR 3 Papite, ft /26*(-14-C6 CV -I. 0,...4 /2..chi Aro* NC-z-- 4;t-c 7 r.- c.c. ,e 7VO4- 0646-41 ...--.7-17ci aver,- fieloaf eft. Use: Residential: New El Replacement 1:1 Commercial: New El Fuel Type: Electric LJ Replacement Gas i"21 Other: HAApplicationfforms-Applicatitms On Line12016 Applications \Mechanical Permit Application Revised I -4-I6.docx Revised: January 2016 bit Page 1 of 2 e Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 4 Ventilation system Hood and duct 4 Incinerator — domestic Incinerator — comni/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO I3E TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: i1TI ORIZED AGENT: Print Name: Mostafa Ahanchi - Authorized Agent for Costco Mailing Address: 1101 Second Ave, Ste 100 Date: l /c3/2\ Day Telephone: (206) 962-6505 Seattle WA 98101 City State Zip H:\Applications\Farns-Applications Revise!_ January 2016 bh J' ions\Mechanical Permit Application Revised 1-4-16.docx Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIP IONS ACCOUNT Pe mitTRAK QUANTITY PAID $3238.62 D19-0292 Address: 400 COSTCO DR 150 Apn: 2523049063 $2,162.07 Credit Card Fee $62.97 Credit Card Fee R000.369.908.00.00 0.00 $62.97 DEVELOPMENT $2,000.33 PERMIT FEE R000.322.100.00.00 0.00 $1,975.33 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $98.77 TECHNOLOGY FEE R000.322.900.04.00 1 0.00 $98.77 M19-0154 Address: 400 COSTCO DR 150 Apn: 2523049063 $496.87 Credit Card Fee $14.47 Credit Card Fee R000.369.908.00.00 1 0.00 $14.47 MECHANICAL $459.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $426.28 TECHNOLOGY FEE $22.97 TECHNOLOGY FEE I R000.322.900.04.00 j 0.00 $22.97 PG19-0126 Address: 400 COSTCO DR 150 Apn: 2523049063 $579.68 Credit Card Fee $16.88 Credit Card Fee R000.369.908.00.00 1 0.00 $16.88 GAS $103.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PERMIT FEE R000.322.100.00.00 0.00 $68.00 PLUMBING $433.00 PERMIT FEE R000.322.100.00.00 0.00 $398.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $26.80 TECHNOLOGY FEE R000.322.900.04.00 0.00 $26.80 TOTAL FEES PAID BY RE . EIPT: R20686 _ . _ _ _ .. ________ . ... _ . . . • $3,238.62 Date Paid: Wednesday, May 06, 2020 Paid By: SCOTT CONRAD Pay Method: CREDIT CARD 0C)4059 Printed: Wednesday, May 06, 2020 2:08 PM 1 of 1 SYSTEMS Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $420.68 EL19-0745 Address: 400 COSTCO DR 150 Apn: 2523049063 $164.35 Credit Card Fee $4.79 Credit Card Fee R000.369,908.00.00 0.00 $4.79 ELECTRICAL $159.56 PLAN CHECK FEE R000.345.832.00.00 0.00 $159.56 M19-0154 Address: 400 COSTCO DR 150 Apn: 2523049063 $118.31 Credit Card Fee $3.45 Credit Card Fee R000.369.908,00,00 0.00 $3.45 MECHANICAL $114.86 PLAN CHECK FEE R000.322.102.00.00 0,00 $114.86 PG19-0126 Address: 400 COSTCO DR 150 Apn: 2523049063 $138.02 Credit Card Fee $4.02 Credit Card Fee R000.369,908.00.00 0.00 $4.02 GAS $25.75 PLAN CHECK FEE R000.322.103.00.00 0.00 $25.75 PLUMBING $108.25 PLAN CHECK FEE R000.322.103.00.00 0.00 $108.25 TOTAL FEES PAID BY RECE PT: R18553 $420.68 Date Paid: Thursday, September 12, 2019 Paid By: SCOTT CONRAD Pay Method: CREDIT CARD 072522 Printed: Thursday, September 12, 2019 11:38 AM 1 of 1 SYSTEMS COTVKWILA ETMAKIT 6200 SOUTMCENT[R 8LVD TUKWILA' WA 98188 206'433z870 CITY OF TUKWILA Date: 09/12/2019 I1:37:48 AM CREDIT [xRo SALE VISA CARD NUMBER: "********9558 K TRAm AMOUNT: $420.68 APPROVAL [D: 072522 RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy INSPECTION RECORD LA Retain a copy with permitL _ NSPIECTI©N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro' t= Type of Inspection: Address: Date Called: ,Special Instructions: Date Wanted: a.m. p.m. Requester: Phone Itio: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee most be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 2/3/2020 MELISSA LORENC 1101 SECOND AVE - SUITE 100 SEATTLE, WA 98101 RE: Permit Application No. M19-0154 COSTCO - BAKERY REMODEL 400 COSTCO DR Dear MELISSA LORENC, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 9/12/2019, has.not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 3/12/2020. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Elisa Villegas Permit Technician File No: M19-0154 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 °PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0154 PROJECT NAME: COSTCO — BAKERY REMODEL SITE ADDRESS: 400 COSTCO DR — SUITE 150 Original Plan Submittal Response to Correction Letter # DATE 01/30/2020 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ?X/ 1` Building Division Public Works OA NU Fire Prevention Structural Planning Division Permit Coordinator I PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 02/04/20 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews DUE DATE: 03117/20 Approved with Conditions Fire Fees Apply Denied (le: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M 107 - Response to Incomplete Letter # El Response to Correction Letter # tg Revision # / after Permit is Issued (pernill- ne veK t:scl/e-ai E] Revision requested by a City Building Inspector or Plans Examiner LI Deferred Submittal # Project Name: Co Si-Cdo 13 et 4e Y4 Project Address: 400 c s-t---co Contact Person: Me Arsca. L-0 k-e el c Summary of Revision: Plea,a47_ $- /Yr( cA-upargi ive Phone Number: 2-0 Co. (a Z. 10 S-25S— RtChIvED CITY OF TUKWILA 3 & 2020 PERMIT CENTER Sheet Number(s): M I, M M /107 ve. vi Sea /. "Cloud" or highlight all areas of revision including date of revis'o Received at the City of Tukwila Permit Center by: intered in TRAKiT on 1-1(9)0-0 WAPermit CenteffemplatesWorms \Revision Submittal Fonadoc Danriecal• LIrnt. V Owner's revisions include: 1. Removal and replacement of (3) bakery ovens and addition of (2) bakery ovens, totaling (5) new bakery ovens. Original scope was totaling (4)bakery ovens with connections for future 5"oven. Z. Removal and replacement of FRPP (wall finish) throughout entire bakery. Original scope was replacing only finish onwall behind existing ovens and proof box. 3. Addition of a 3 d mixer. Original scope showed the re -use of 2 existing mixers only. 4. Addition of (2) trench drains in the department as well as an additional floor sink for the equipment condensate lines. Original scope was not adding any drainage to department. 5. Demolishing the entire ceiling tile and grid, lighting and duct work in order to raise the entire new ceiling approximately V-15' in order to accommodate required equipment clearances. C>r/g/no/scmpem/msmep/ucingtheentireceiling like for like otsome height. 8. Demolishing wall between the Bakery and the MPU room and rebuilding to accommodate the new ceiling height, as well as adding a new ceiling to the MPU room. Original scope didn't affect this area. 7. Demolishing and sealing off (2) existing refrigeration doors and relocating one of them to accommodate stud walls for plumbing fixtuves.Orio/no/scc9/edidn'trequirethis 8. Demolishing entire front cooler of department and 2 bays of high pile storage to create a cake decorating space in the department. This area will have a partial wall as well as new signage to wrap around the front corner of the department. Original scope did not include this. 9. Removing the door inthe back nfthe Bakery. Orig/no/scc4/ew/msgo/ngtoturnthisspuce/nbno Storage Room. 10. VVewill also beclearing out the space adjacent tothe Bakery for possible future work. This includes the removal of racking, sinks, and a hazard cage. We will also be removing a water fountain and a sink in the Demonstration room in the back of the warehouse as part of this permit. All of the new work outside of the Bakery is shown on A501.3 for clarity. 11. AN of the changes in scope of work have been reflected on all of the sheets in the Permit Issue Set for Plan Review. Completely new sheets have been added for Fire and Structural review as these were not required for the original scope ofwork. - M 1" 15 Ll nECEIVED CITY OF TUKWILA --' 30 202m bP:RMT ClIORD POPY0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0154 DATE: 10/01/2019 PROJECT NAME: COSTCO - BAKERY REMODEL SITE ADDRESS: 400 COSTCO DR Original Plan Submittal Revision # X Response to Correction Letter # 1 Revision # before Permit Issued after Permit Issued DEPARTMENTS: 104't uilding Division le Public Works Fire Prevention Structural Lil Planning Division Permit Coordinator LI • PRELIMINARY REVIEW: Not Applicable 0 (no approval/review required) REVIEWER'S INITIALS: DATE: 10/01/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required El (corrections entered in Reviews) DUE DATE: 10/29/2019 Approved with Conditions 0 Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg O Fire 0 Ping 0 PW Staff Initials: 12/18/2013 Li [E] Response to Correction Letter # 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M19-0154 Response to Incomplete Letter # El Revision # after Permit is Issued RECEIVED CITY OF TUKWILA 0 Revision requested by a City Building Inspector or Plans Examiner Ei Deferred Submittal # Project Name: Costco - Bakery Remodel Project Address: 400 Costco Dr Contact Person: met-i se ort L-ofzeNC- Phone Number: 2-0(9. 49 2- • 49%-17S- SEP 2 6 2019 PERMIT CENTER Summary of Revision: PLa //si 0E.4/ $,E4D j2 C P f iNAT rD cfry -rue-vv et), 1-40/ /ye C:).-P A-12_1-m 04tcr- 44 -f\/ Ts All, PP--#414/ A/ Cq C44-74-1\/ c4...0 tj enF..-40 g J(\ LO A/C-7 1,1=*r_ 12o s en r1, I Hilva PL4- U r—. -11-1A-ry V0L 44 n/1 SSA- W--04\1 Sheet Number(s): "Cloud" or highlight all areas of revision including date ofre ion Received at the City of Tukwila Permit Center by: Entered in TRAKiT on CAUsets\MelissaL \AppData \LocalWlictosoft \Windows UNIetCache \ContentOutlook4LFOQJIC \Revision Submittal Form,doc . . T.E., Inc. TEXAS Registered Engineering Firm F-002887 830 North Riverside Drive, Suite 200 Renton, Washington 98057 Phone: 425-970-3753 / FAX: 425-970-3756 www.tei-engineering.com September 26, 2019 MG2 1101 Second Ave. Ste 100 Seattle, WA 98101 Attn: Melissa Lorenc Re: Costco Wholesale —Tukwila, WA (#006) Bakery Upgrade (TEI#18-688)(MG2#93-0440-36) Dear Melissa The following are the written responses to the building department comments 1. Sheet M-1 Enlarged Bakery FIVAC Plan, the detail for the rack washer indicated a detail [21] please clarify where that detail is. Response: Detail 21 added to sheet M-1. 2. Gas calculations indicates 4" service acceptable. The plan only shows 3". Please clarify. Response: 4" gas service not for bakery but for entire store. 3. Engineer's signature is missing the date of signature. Please provide engineer's sheet stamped, signed and dated. Response: Date Added Sincerely, Cameron Glathar Mechanical Engineer iEFVED CITY OF TUKWILA SEP 26 2019 PERMIT CENTER m LOIF 0 City of Tukwila Department of Community Development September 26, 2019 MELISSA LORENC 1101 SECOND AVE - SUITE 100 SEATTLE, WA 98101 RE: Correction Letter # 1 MECHANICAL Permit Application Number M 19-0154 COSTCO - BAKERY REMODEL - 400 COSTCO DR Dear MELISSA LORENC, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11 x 17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Sheet M-1 Enlarged Bakery HVAC Plan, the detail for the rack washer indicates a detail [21] please clarify where that detail is. 2. Gas calculations indicates 4" service acceptable. The plan only shows 3". Please clarify. 3. The engineer's signature is missing the date of signature. Please provide engineer's sheet stamped, signed and dated. See general note above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. M19-0154 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 9ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0154 DATE: 09/12/19 PROJECT NAME: COSTCO - BAKERY REMODEL SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued 1 ,PARTMENTS: Corq, 9-13.-11 Building Division Public Works ire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 09/17/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 10/15/19 Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Fire D Ping PW [j] Staff initials: DATE: 12/18/2013 JACKSON DEAN CONSTRUCT 0 Some online services are currently un vailable. See a list of service outages. (https://iaima.goviagency/system-slatus) Page 1 of 3 L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m. to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional officelhIlDs://lnima.clov/aoencyhcontact/#officetocations), or you can call the Office of Information and Assistance at 360-902-5800. k)iabor & industries chttoslijoLvve.govi JACKSON DEAN CONSTRUCTION Owner or tradesperson Principals JACKSON, MILES GORDON, PRESIDENT KEENER, LAURIE ANN, SECRETARY VANDENBERG, JERRY, PRESIDENT (End: 12/06/2010) VANDENBERG, MARSHA, SECRETARY (End: 12/06/2010) GONZALES, KARN D, VICE PRESIDENT (End: 12/09/2010) BUTLER, DAVID, CHIEF EXECUTIVE OFFICER (End: 12/09/2010) Doing business as JACKSON DEAN CONSTRUCTION WA UBI No. 601 222 672 19835 SE 248th Street MAPLE VALLEY, WA 98038 206-832-2900 KING County Business type Corporation Governing persons MILES GORDON JACKSON KARN DUREEN GONZALES; JERRY VANDENBERG; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. JACKSDC962QR ( 1-11-1r•c, • //c4ar,rrn. 1,i xxra rtr,r/N7ar; Rr/Tlot,141 ortv 9T TR T=An 1 111A71 T IC.T A CV cnr0K1f117 R A \IT= 57 PM, TLeitch — WA — Bakery Upgrade\ 688M-1.dwg, 1/28/2020 Costco — Tukw K:\2018\680-689\18-688 DOMESTIC WATER NOTES THE FOLLOWING NOTES APPLY TO THE ENTIRE PLAN AS APPUICABLE. GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO THE ENTIRE PUN AS APPUCABLE. - RUN ALL PIPING IN TRUSS SPACE, EXCEPT FOR WHERE COVERED BY EQUIPMENT PLATFORM OR LOCATED IN CEILING SPACE AT FRAMED ANCILLARY AREAS - PROVIDE ALL HAND SINKS WITH THERMOSTATIC MIXING VALVE LOCATED BELOW SINK TO REDUCE WATER TEMPERATURE TO 110'F. - ALL NON -HAND WASHING SINKS ARE SERVED BY 140'F HOT WATER. POST WARNING SIGNS READING "CAUTION! 140'F HOT WATER". PIPING SYSTEMS THE FOLLOWING NOTES APPLY TO THE ENTIRE PLAN AS APPLICABLE. - APPLICABLE PLUMBING CODE:2015 UPC - ALL WASTE PIPING, CONDENSATE PIPING & STORM DRAIN PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. - SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE IN FINISHED ROOMS OR COOLERS. PIPING AND CONDUIT OF ALL TYPES SHALL BE CONCELAED WITHIN WALLS, FLOORS, OR CEILINGS (INCLUDING CONDENDSATE DRAIN LINES, WATER HEATER PRESSURE RELIEF LINES AND SODA LINES.) - INSULATE ALL INTERIOR PIPING; STORM DRAIN, HOT, COLD RECIRC, AND CONDENSATE PER SEPCIFICATION SECTION 22 07 00. - PIPING IN ROOF TRUSS SPACE TO BE RUN PEPPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS. FOR PASSING BELOW SOLID GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK LIGHTING & SKYLIGHTS - M.C. SHALL ENSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES HVAC UNITS AND EXHAUST FAN. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. - MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. - COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OF PANELS - DIMENSIONS ARE TO COLUMN LINES. - APPLICABLE BUILDING CODE:2015 IMC APPLICABLE MECHANICAL CODE:2015 IBC APPLICABLE ENERGY CODE: 2015 WSEC - PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. - FIELD VERIFY EXISTING FIRE SPRINKLERS AND DUCT DETECTORS. REINSTALL AND RECONNECT DUCT DETECTORS OR REPLACE WITH EQUAL. - ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. - RUN PIPING IN TRUSS SPACE PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS. FOR PASSING BELOW SOLID GIRDERS MOUNT PIPING 6" MAXIMUM. FROM BOTTOM OF GIRDER. DO NOT BLOCK LIGHTING AND SKYLIGHTS AIR TERMINAL SCHEDULE SYMBOL MANUFACTURER SERVICE MODEL PATTERN DAMPER NECK FRAME LOCATION * CD TUTTLE & BAILEY SUPPLY SQD BLADE LAYIN OFFICES, OPTICAL RGFP** TUTTLE & BAILEY RETURN CT7ODFB-SS 45' FIXED BLADE LAYIN BAKERY WSG TUTTLE & BAILEY SUPPLY T54 FIXED BLADE FLANGE * VERIFY NUMBER OF DIFFUSERS AND ALL LOCATIONS ON PLANS - DIFFUSER IS NOT REQUIRED IF NOT ON PLANS ** DIFFUSER TO HAVE BRUSHED STAINLESS STEEL FACE. DO NOT PROVIDE WITH FILTER. KITCHEN EXHAUST EQUIPMENT SCHEDULE - S.O.I.C. SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES KEF 7�9 KITCHEN EXHAUST FAN BAKERY OVENS CAPTIVEAIRE DU85HFA 1000 CFM 00.60" SP. PROVIDE WITH FLOATING HINGE. CONTROLLED BY OVENS. PROVIDED BY E.C. UL 762 LISTED. 3/4HP 120V/10 97# 16/M CONTRACTOR TO PROVIDE ADAPTOR CURB (1) KEF-10,11 KITCHEN EXHAUST FAN BAKERY OVENS CAPTIVEAIRE DU85HFA 1000 CFM 0 0.60" SP. PROVIDE WITH FLOATING HINGE. CONTROLLED BY OVENS. PROVIDED BY E.C. UL 762 LISTED. 3/4HP 120V/10 97# 16/M (2) KEF-22 KITCHEN EXHAUST FAN PAN WASHER CAPTIVEAIRE DU33HFA 1O5OCFM 00.38" SP. INTERLOCK WITH LIGHTS BY 12-HR TIMER SWITCH 1/3HP 120V/10 70# 16/M 16" SQ. ROOF OPENING (1) (4) KTF-13 THRU 17 KITCHEN TRANSFERKENSITIEAI FAN BAKERY CAPTIVEAIRE 1500 CFM 00.25" SP. INLINE TRANSFER FAN SUSPENDED FROM ROOF TRUSSES. INTERLOCK WITH OVENS 3/4 HP 12010 20 MCOP 130# 24 M / 3 ( ) GENERAL NOTES: (APPLIES TO ENTIRE SCHEDULE AS APPLICABLE) T-STATS MOUNTED AT 42" AFF UNLESS OTHERWISE NOTED SEE DESCRIPTION FOR RESPONSIBLE CONTRACTOR. PROVIDED BY G.C. G.C. TO CONTACT APPROVED SUB -CONTRACTORS FOR ANSUL SYSTEM INSTALLATION. SYSTEM TO INTERLOCK WITH CAPTIVAIRE CONTROL CABINET. COLUMN ON RIGHT FOR APPLICABILITY): PROVIDED BY GC GC TO MAX AND RECORD AIR VOLUME IN AIR SCHEDULE. DAMPER. 1. ALL SWITCHES AND 2. ANSUL SYSTEM 3. COORDINATE ANSUL SCHEDULE NOTES: (SEE (1) ADAPTER CURB (2) ROOF CURB BY (3) ADJUST FAN SPEED (4) PROVIDE BACKDRAFT FRESH LINE EQUIPMENT SCHEDULE - (S.O.I.C) ARCH. NUMBER SYMBOL DESCRIPTION MFR./MODEL WASTE VENT COLD W. HOT W. COMMENTS DETAIL SERVES NOTES BACKFLOW PREVENTION 4 E-1 HAND SINK UNIVERSAL 1-1/2" 1-1/2" 1/2" 1/2" 16" X 16" X 16" TYPE 304 STAINLESS STEEL, WALL HUNG, WITH WALL BRACKET FISHER F1-3174 KNEE VALVE, 3816 GOOSENECK SPOUT. 28/P MEAT, BAKERY, DELI, ROTISSERIE (1)(3)(6) LH-BS AG 200 E-5 WATER METER STM DOMIX 1/2" 1/2" WALL HUNG WATER METER AND BLENDER UNIT, WITH INLET STOPS, CHECKS AND VACUUM BREAKERS. 50/P BAKERY (1)(2) LH-BS AG 203 E-6 RACK WASHER LVO INDIRECT 1" UNIT WITH RINSE BOOSTER AND STEAM VENT FAN. RUN DRAIN TO FLOOR SINK - TERMINATE WITH 1" AIR GAP. 66 MBH GAS INPUT. 49/P BAKERY (1)(2) LH-BS/BP AVB 206 E-7 OVEN HOBART AKA BAXTER OV500G2-EE 1/2" UL LISTED INTEGRATED OVEN AND FULLY WELDED TYPE II HOOD FOR NON GREASE LADEN VAPOR. INTEGRAL OVEN WITH HOOD AND AIRFLOW DRAFT PROVING SWITCH ARE PROVIDED AND ASSEMBLED BY OWNER, INSTALLED BY CONTRACTOR. 350 MBH GAS INPUT, 750 CFM REQUIRED. 14/P BAKERY (1)(2) LH-BS/BP 204 E-8 PROOFER BOX HOBART/PW3S 3/8" UNIT W/HUMIDIFIERS PROVIDED & ASSEMBLED BY OWNER. BAKERY (1)(2) LH-BS/BP AG 1 E-17 DETERGENT RACK KAY CHEMICAL AT 4 COMP SINK - 1/2" TEMPERED WATER FROM MV-2 0+16" A.F.F. VENDOR WILL MAKE FINAL CONNECTION FROM ROUGH IN BELOW THREE -COMPARTMENT SINK. AT PAN WASHER - 1/2" TEMPERED WATER FROM MV-2 0+60" A.F.F. 40/P (4) LH-BS AG AVB 618 E-18 DEMO SINK STORAGE PRODUCTS GROUP PC-3N1824 -2D18 3" 2" 3/4" 3/4" 91" X 29-3/4" - TYPE 304 STAINLESS STEEL WITH 18.5" DRAIN BOARD ON RIGHT KOHLER FAUCET, SOPA DISPENSER SINK (3) LEVER WASTE AND OVERFLOWS. 25/P DEMO ROOM (1)(2)(6) LH-AG AG 202 E-22 FOUR COMPARTMENT SINK UNIVERSAL 2" 3/4" 3/4" 150" X 35-1/2" X 43" - TYPE 304 STAINLESS STEEL WITH DRAINBOARDS AND UNDERSHELFS. INCLUDES FISHER 3253 FAUCET & FISHER 2210 PRE -RINSE W/ADD-A-FAUCET, SS PANEL TO BE MOUNTED BEHIND SINK AND (3) LEVER DRAIN. 40/P MEAT, BAKERY, DELI, ROTISSERIE (1)(7) LH-BS AG (1) (2) (3) (4) (6) (7) EQUIPMENT FURNISHED BY THE OWNER. THE MECHANICAL CONTRACTOR SHALL ROUGH -IN PLUMBING, INSTALL AND CONNECT ALL SERVICES ALL P-TRAPS, TAILPIECES, ESCUTCHEONS, AND STOP VALVES SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. CONTRACTOR SHALL RECEIVE, UNCRATE, AND INSTALL. PROVIDE RIGHT AND LEFT SPLASH GUARDS IN MEAT PREP. ONLY. EQUIPMENT SUPPLIED AND INSTALLED BY OWNER(S.I.O.). THE MECHANICAL CONTRACTOR SHALL ROUGH -IN PLUMBING AND PROVIDE SHUTOFF VALVES AND ESCUTCHEONS. VENDOR TO MAKE ALL FINAL CONNECTIONS. M.C. TO PROVIDE WATTS USG-B-M1 THERMOSTATIC MIXING VALVE. CONTRACTOR TO PROVIDE 90 DEGREE ELBOW WITH BALL VALVE AND CHECK VALVE WITHIN 3" OF WALL. HAZARD TYPE BACKFLOW POTENTIAL LH - LOW HAZARD HH - HIGH HAZARD BS - BACK SIPHONAGE BP - BACK PRESSURE BACKFLOW PREVENTION RPZ - REDUCED PRESSURE PRINCIPLE BACK FLOW AVB -PRESSURE VACUUM BREAKER AG - AIR GAP AVB - ATMOSPHERIC VACUUM BREAKER NOTE: GAS PRESSURE TO BE VERIFIED AT BAKERY BEFORE ANY GAS WORK. VERIFY CONDITION AND LOCATION OF EXISTING BAKERY PRV CONNECT NEW 1-1/4" GAS TO (E) 3" GAS. VERIFY LOCATION OF (E) PRV IS BEFORE OVEN CONNECTIONS. (TYP OF 2) E-7 SEE DETAIL KERY OVEN 13 1 /4"BGAS DN (TYP. OF 3) FIELD VERIFY GAS SIZING. PLUMBING FIXTURE SCHEDULE - CONTRACTOR PROVIDED SYMBOL DESCRIPTION MFR./MODEL WASTE VENT COLD W. HOT W. SPECIFICATIONS DETAIL SERVES NOTES BACKFLOW PREVENTION D-3 FLOOR SINK DRAIN STAINLESS DRAINS.COM CSD8X8X6P 3" 2" 8X8X6"DEEP FLOOR SINK WITH 14 GA STAINLESS STEEL BODY. DRAIN PROVIDED WITH PERFORATED 12 GA STAINLESS 1/2 GRATE, DOME STRAINER, FLASHING COLLAR AND 3" NO HUB ADJUSTABLE HEIGHT OUTLET. 23/p BAKERY OVENS (12) N/A D-4 FLOOR SINK DRAIN STAINLESS DRAINS.COM CSDSINK12X12X10 1 /2PIFDS 4" 2" INDIRECT SINK WASTE, 12" SQUARE EXTRA DEEP 14GA STAINLESS STEEL RECEPTOR. DOME BOTTOM STRAINER, NO HUB ADJUSTABLE HEIGHT OUTLET, PERFORATED 1/2 GRATE AND INTERNAL FLANGE. 23/p MEAT, BAKERY, DELI, FOOD SERVICE (12) N/A D-6 FLOOR DRAIN STAINLESS DRAINS.COM SDS14X8 4" 2" HEAVY DUTY, 1/2" STAINLESS PERIMETER GAP GRATE WITH 8 GA TYPE 304 STAINLESS STEEL BODY, ANCHOR TABS, NO -HUB, ADJUSTABLE OUTLET, PERFORATED OUTLET STRAINER WITH LOCK PINS AND STAINLESS STEEL SEDIMENT BASKET. 90/P RACK WASHER PIT (12) N/A MV-2 THERMOSTATIC MIXING VALVE SYMMONS MAXLINE 7-230-CK 3/4" 3/4" MIXING VALVE WITH LOCKABLE TEMPERATURE SETTING AND HOT AND COLD CHECKS, SET TEMPERATURE TO 100' F. 32/p 26/p PUBLIC RESTROOM, FRESHLINE, DEMO ROOM N/A TBV THERMOSTATIC BALANCE VALVE CIRCUIT SOLVER CSUA SELF ACTUATING THERMOSTATIC BALANCING VALVE FOR DOMESTIC HOT WATER RECIRCULATION SYSTEMS. STAINLESS STEEL CONSTRUCTION. 10'F OPEN/CLOSE RANGE. NSF-61 CERTIFIED. SEE PLANS & DETAIL FOR QTY., SIZES AND SETPOINTS. 80/p MEAT, BAKERY N/A TD-# TRENCH DRAIN LENGTH=5,10,20 LENGTH=15,25 STAINLESS DRAINS.COM CSD6X# SLOTTED 4' 2" 14GA STAINLESS STEEL BODY WITH CATCH BASIN AND 1/4" STAINLESS STEEL SLOTTED GRATE, 16 GA 6X24" SDSB SEDIMENT BASKET. FOR TD-5 PROVIDE INTEGRAL BUTTERFLY LOCK. 37/P MEAT PREP, ROTISSERIE N/A 712) NATIONAL PURCHASE AGREEMENT IN PLACE WITH STAINLESSDRAINS.COM CONTACT SHANNON BAKER AT (888) 785-2345. (E) 3" (1,470 MBH) } (E (1,120 (E)3" GAS DOWN 3 MBH) (E) 3" (420 MBH) E) 3 (770 MBH) 3/4" (70 MBH) CONNECT NEW 3/4" GAS TO..._. (E) 3" GAS. FIELD VERIFY SIZE AND LOCATION. LSJ ail PARTIAL FLOOR PLAN SCALE: 1/16" = 1'-0" SEE DETAIL RACK WASHER (70 MBH) 3/4" DN GAS SIZE CHART PRESSURE PRESSURE MAX DEVELOPED PSI DROP LENGTH (FEET) 2 TO 1.0 800 PIPE SIZE (UPC) MAX"LOAD (MBH) 1,." 141 3/4" 295 " 556 1-1/4" 1,141 1-1/2" 1,709 3,291 2-1/2" 5,245 3" 9,273 4" ' .1.8,914 6" 55,407 8" 113,841 PROVIDE ONE OF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT WITH VENT TO OUTSIDE OR VENT LIMITER ON MAXITROL SENSUS MODEL #496 PIPE SIZE - 3/4" OR 1" ORIFICE - 3/8" SPRING - GREEN FOR GAS LOAD UP TO 760 MBH MAXITROL MODEL: GAS LOAD UP TO 340 MBH 325-5L600 PIPE SIZE - 3/4" OR 1" GAS LOAD BETWEEN 340 MBH AND 1000 MBH 325-7AL210D PIPE SIZE 1-1/4" OR 1-1/2" *ALL GAS PRESSURE REGULATORS TO BE RATED FOR 5 PSI. FiE Pcsrmlt No, Tart tevit,v,d L cans 2 (ntrze v w u r'1mdnC@ f3F a its p GAS SIZE CHART PRESSURE PRESSURE MAX DEVELOPED IN WC 7 DROP TO 6.5 LENGTH (FEET) 100 PIPE SIZE (UPC) MAX LOAD (MBH) 1/2" 45 3/4" 94 1" 177 1-1/4" 363 1-1/2" 544 2" 1,048 2-1/2" 1,672 3" 2,956 4" 6,032 6" 17,683 8" 36,348 GAS CALCULATIONS EXISTING LOAD 4,142,000 BTU/H REMOVED LOAD BAKERY OVEN -1,050,000 ADDED LOAD BAKERY OVEN +1,400,000 RACK WASHER +70,000 TOTAL GAS LOAD 6,142,000 BTU/H 4" SERVICE ACCEPTABLE 0 2" PSI SON NOl A[ i.TE. PERMIT REQLHRE0 FOR: C Medhrnical EV Electrical Plumbing . ..,ia3 Piping C-Tuitwila (�;,_;D,.S!Ci REVISIONS NOTES, AND SCHEDULE _ _ z ! R�V!EV1n ) FOR CODE COMPLIANCE ICE APPROVED a� ;f s 0.1YLi 2020 U �Jv P a t,ih,T of c Gila Q BUILDING iNV!Sv)NN ? U RECEIVE) C/) CITY OF TUKWILA e� JAN 30 2020 PERMIT CENTER Mi3-01qA 0,03 2U2t z CHECKED: PKR/CWC DRAWN: CJG REVISION DATE: JANUARY 28, 2020 ISSUE DATE: NOVEMBER 2018 ARCHITECT REFERENCE NO: 93-0440-36 O z z0i 1- w0 ow 00 0 0 Z w CO CC a M 0 0 za w w O O� O -0 3 w� o� Ha CC aZ zZo Q PROJECT NO:18-688 I ISSUED FOR PERMIT rn 0 0 o Z N O] W CC CC TMENT RESPONSES z sN 05 w 0 w o a o 0 E-I N 0, 0 1 0 0 m 5) M -1 WA — Bakery Upgrade\_688M-2.dwg, 1/28/2020 4:02:10 UM, TLeitch K:\2018\680-689\18-688 — Costco — Tukwila (#006) CONNECT NEW 1/2" C TO (E) CW. PROVIDE VALVE & STRAINER. (TYP OF 2) CONNECT NEW 1/2" H&CW TO (E) H&CW. FIELD VERIFY LOCATION. (E)1/2" HW DN TO OVEN AND PROOFER W/VALVE & SEINER SEE DETAIL (TYP. OF 6) E-1 SEE DETAIL HAND SINK 1/2" H&CW DN Ara A2ict ww 12"0 EXHAUST 'UCT— UP TO ROOF® SEE DETAIL liMPAIDEF Man Zffik INA SEE DETAIL TRANSFER FA ABOVE CEILING (TYP. OF 5) 18/18 DUCT. (TYP. OF 4) SEE DETAIL DEMO EXISTING H&CW DROPS. CAP AT MAIN. ENLARGED BAKERY PLUMBING PLAN SCALE: 1/8" = 1'-0" MEW 24/24 RGFP 1500 CFM (TYP. OF 5) ENLARGED BAKERY HVAC PLAN SCALE: 1/8" = 1'-0" ® SEE DETAIL 28 HAND SINK 1/2" H&CW DN (E)1/2" (E)3/4" Mill& AM 11/1Y1IY 0 1/2" ED FROM TO AT RA HE ONNECT NEW 3/4" HWC TO INLET AT DEMO ALL DUCTWORK, REPLACE WITH NEW 12"0 DUCT. DEMO AND REPLACE EXHAUST FANS 8,9,10 ON ROOF. EXISTING CURB TO REMAIN. PROVIDE CURB ADAPTOR AS REQUIRED. PROVIDE DUCT OFFSET AS NEEDED. SEE DETAIL 00 au=■, • EXISTING WATER HEATERS. FIELD VERIFY LOCATION. SEE DETAIL ZURN 80 SHOKTROL #100 RUN 1" HW DOWN FROM CEILING AND TIGHT TO BACK SIDE OF RACK WASHER TO ALLOW ACCESS. SEE DETAIL ¢9 E-22 MV-2 SEE DETAIL 40 4-COMP SINK W/ MIXING VALVE FOR DETERGENT DISPENSER 3/4" H&CW DN ® 4 LOCATIONS SEE DETAIL HAND SINK 1/2" H&CW DN SEE DETAIL WATER METER 3/4" HW & CW 1/2" CW DN. 50 DEMO EXISTING SINK IN HATCHED AREA. CAP (E) H&CW ABOVE CEILING. (TYP OF 4) SEE DETAIL 0 3-COMP SINK W/ MIXING VALVE FOR DETERGENT DISPENSER 3/4" H&CW DN CONNECT NEW 1/2" H&CW TO (E) 3/4" H&CW. SEE DETAIL 28 HAND SINK 1/2" H&CW DN 4"0 FLUE FOR RACK WASHER. OFFSET FLUE PENETRATION 8' AWAY FROM PARAPET WALL. SEE DETAIL/'-\ — 4 E-6) SEE DETAIL 0 8"0 CPVC STEAM VENT UP TO ROOF 24/24 EG-3 ® 1050 CFM. LOCATE ABOVE RACK WASHER DOOR. SEE DETAIL (is EXHAUST FAN 12/12 DUCT UP TO UNIT ON ROOF RUN CONDENSATE FROM NEW OVENS AND PROOFER TO NEW FLOOR SINK SEE DETAIL CONNECT NEW 2" WASTE TO (E) 4" WASTE. FIELD VERIFY LOCATION, SIZE AND IE. CONNECT NEW 3" WASTE TO (E) 4" WASTE. FIELD VERIFY LOCATION, SIZE AND IE. CONNECT NEW 3" WASTE TO (E) 3" WASTE. FIELD VERIFY LOCATION, SIZE AND IE. CONNECT NEW 2" VENT TO (E) 3" VENT. (TYP) ENLARGED BAKERY WASTE ANI) VENT PLAN SCALE: 1/8" = 1'-0" CONNECT WASTE FROM 4-COMP SINK TO EXISTING WASTE RISER WALL. SEE DETAIL / \ RUN 2" WASTE IN WALL TO EXISTING WASTE RISER. CONNECT NEW 4" WASTE TO (E) 4" WASTE. FIELD VERIFY LOCATION AND IE. APRROX. 42" MIN. DEPTH. VERIFY BEFORE CONSTRUCTION CONNECT NEW 4" WASTE TO (E) 4" WASTE. FIELD VERIFY SIZE, LOCATION AND IE. DEMO EXISTING DRAIN. PATCH FLOOR TO MATCH SURROUND. CONNECT NEW HANDSINK TO (E) WASTE IN WALL. CONNECT NEW 2" WASTE TO (E) 2" WASTE. FIELD VERIFY LOCATION, IE, AND SIZE. DRAIN NEW 3-COMP SINK TO EXISTING FLOOR SINK. FIELD VERIFY LOCATION. RUN 2" WASTE FROM HAND SINK TI HT TO WALL. DAYLI ABOVE FLOG 3-COMP. )Pf �WE FOR E OMPLIANC APPROVED RECEIVED CITY OF TUKt1ILA JAN 30 2020 PERMIT CENTER OWNER REVISIONS G AND WASTE & VENT ENLARGED ROOF CEILING FRONT OF OVEN FLOOR SIZE PER PLAN "'-GAS COCK SEE PLANS FOR GAS INPUT. DRIP LEG EXTEND 1" DRAIN LINE FROM TEE TO ABOVE DDD OVEN FOR CLEANOUT OUTLET FROM OVEN AT 5-1/2" A.F.F. ROUTE 1"DRAIN LINE ABOVE GRADE TO DAYLIGHT 2" ABOVE FLOOR SINK. (TYP. OF 4) SEE PLAN FOR LOCATION NOTE: CONTRACTOR TO VERIFY CONNECTIONS AND THEIR LOCATIONS WITH MANUFACTURER. 1" DRAIN UNE. LOCATE CLEANOUT ABOVE PROOF BOX 1/2" CW NPT CONNECTION OVEN DETAIL E-7 SCALE: NONE 30" SIDE ELEVATION SPECIFICATION: MANUFACTURER: THERMOMEGATECH BRAND: CIRCUIT SOLVER MODEL: CSUA-XX-YYY XX=PIPE SIZE (1/2 OR 3/4) YYY=DESIGN TEMP WH-1,2 = 140'F BALL VALVE WH-5 = 120'F (TYP. OF 2) NOTE: DIAGRAMMATIC REPRESENTATION OF HOT WATER RECIRCULATION SYSTEM. REFER TO PLAN AND DETAILS FOR ACTUAL PIPING LAYOUT AND SIZES. THERMOSTATIC BALANCING VALVE (QTY. PER PLAN) = FLOOR SINK PLAN VIEW 1" DRAIN LINE. LOCATE CLEANOUT ABOVE OVEN. (TYP. OF 3) SLOPE 0 1 % TBV THERMOSTATIC BALANCING VALVE INSTALLED IN ACCESSIBLE AREA. PROVIDE SIGHT FLOW INDICATOR. M/N: W.E. ANDERSON SFI-100MP HOT WATER TO FIXTURES. (TYP) THERMOSTATIC BALANCING VALVE DETAIL SCALE: NONE 5' FLOW b 5' INV.= z2 24" SEDIMENT BASKET MID CATCH BASIN. INV= 6.0 20' 25' 5' I 1 Nv= zz 4" NO -HUB BOTTOM OUTLET INV...12.0 (TD-20 INV6. s.s 5' I' 5' k FLOW 4, III - z2 IW I I B.6 24" SEDIMENT BASKET AND CATCH BASIN. FI OW' 1 INV.6.6 24" SEDIMENT BASKET) AND CATCH BASIN. f 5' FLOW c INv.- 6.0 24' SEDIMENT BASKET AND CATCH BASIN. FLOW 6 k INV.- 6.0 1' 15' 5' t INV.- 6.6 4" NO -HUB BOTTOM OUTLET INV=12.0 (TD-15 .1 FLOW INV.= 6.0 END CAP (TYP. OF 2) TEND OAP INV.- 6.0 k 22-3/4" GRATE k !1111111111111111111111111 END CAP I, 24" GRATE I, I f r- (TYP. OF 2) 1f ROTISSERIE ONLY" INV.= INV= 6.6 6.0 —4" NO -HUB BOTTOM OUTLET INV -12.0 GRATE NOTES: - CUTTING GRATE IS NOT NECESSARY. (TD-10) - REMOVE (1) SECTION IN ROTISSERIE AREA 5' TO ALLOW CLEAR SPACE FOR OVENS TO FLOW DRAIN. 1NV=END CAP 6.0 (TYP. OF 2) 4" NO -HUB BOTTOM OUTLET INV.=12.0 ITOP ELEVATION' 5' k FLOW END CAP (1YP. OF 2) INV.= 6.0 —4" NO -HUB BOTTOM OUTLET WITH INTEGRAL BUTTERFLY LOCK. INV.=12.0 —12" SEDIMENT BASKET AND CATCH BASIN. 1% FLOOR AT TRENCH DRAIN IN BACK OF ROTISSERIE OVENS IS LEVEL WITH DRAIN (DASHED UNE) a FLOW GRATE REFERENCE TRENCH DRAIN NOTES' - DO NOT SLOPE FLOOR AROUND TRENCH DRAINS IN ROTISSERIE AREA DOING OVENS MD DEL!/IEAT COOLER MANCE. - SLOPE FLOOR 1'-0" PERIMETER 0 1% SLOPE AROUND TRENCH DRAINS IN MEAT PREP, DEU PREP, AND ROTISSERIE PREP AREA. 8 1/2° 4' MIN. /- 1% INVERT SECTION VIEW 4 MIN. SD6X25—SECTION 4" TRAP & ARM TRENCH DRAIN (TD-10) SCALE: NONE P EXHAUST FAN TERMINATION SHALL DISCHARGE A MIN. OF 40" ABOVE ROOF. GALVANIZED CEILING. HINGE EXISTING CURB ON ROOF. FIELD VERIFY PROVIDE VERTICAL SUPPORT ASSEMBLIES PER MANUFACTURER'S INSTRUCTIONS. 12 "0 DUCT ._ CAPPED 12"0 TEE FOR FUTURE CONNECTION. CAP 10" DUCT HERE FOR FUTURE OVEN. SEE PLANS FOR LOCATION. STAINLESS STEEL DUCT BELOW STAINLESS STEEL SLEEVE FOR 10"0 BAKERY OVEN ,� /' �-CEILING EXHAUST THROUGH CEILING. RISER 10"0�1 18 GAUGE STAINLESS STEEL EXHAUST HOOD W/ WELDED FILTER SEAMS. NOTES: ()EXHAUST FAN CONTROLLED BY OVEN. ©PROVIDE 4" STAINLESS STEEL BASE SHOE W/ BEVELED BOTTOM EDGE ALONG THE BOTTOM OF PROOF BOX THAT COMPLIES WITH LOCAL HEALTH CODES. ©PROVIDE STAINLESS STEEL CLOSURE PANEL AT OVEN SIDE OF PROOF BOX AND AT REAR OF PROOF BOX. FLOOR CONTRACTOR TO VERIFY CONNECTIONS AND THEIR LOCATIONS WITH MANUFACTURER. SIDE ELEVATION FACTORY WELDED ( �"V" CLAMP TO BE PROVIDED LONGITUDINAL SEAM. I BY DUCTWORK MANUFACTURER. DUCT FLANGE. SEAL WITH 3M FIRE BARRIER 2000+ HIGH TEMP SILICONE SEALANT. NOTES: DUCT CONNECTION 1) DUCTWORK/FLUES SHALL RUN STRAIGHT FROM EQUIPMENT TO ARCHITECTURAL FINISH WITH NO OFFSETS. MAKE OFFSETS WITH FITTINGS ABOVE CEILINGS, BEHIND WALLS OR IN ROOF STRUCTURE WITH AS SMALL AN ANGLE OF OFFSET AS POSSIBLE. G.C. TO COORDINATE THE LOCATION OF SPRINKLER HEADS SO THAT THEY ARE NOT IN CONFLICT WITH THE VENT DUCTWORK. PROVIDE STAINLESS STEEL DUCT BELOW CEIUNG AND GALVANIZED DUCT ABOVE CEILING. 2) EXHAUST DUCT TO BE FACTORY BUILT BY CAPTIVEAIRE. SEE SPEC 233800 FOR ORDERING. CONTACT: ATTN: COSTCO PROJECT MANAGER ® (425)212-5996 OR REG850CAPTIVEAIRE.COM 3) ALTERNATIVE: NORDFAB QUICK FIT 22 GAUGE GALVANIZED 4' OTHER ALTERNATIVE DUCT TO BE APPROVED BY MECHANICAL ENGINEER. 5 ALL DUCTS TO HAVE WELDED LONGITUDINAL SEAMS AND CLAMP LOCKS. OVEN DETAIL E-7 SCALE: NONE 94" 18" 18" 18" 11 18" 18" ii PLAN VIEW TRIPLE COMPARTMENT SCALE: NONE SINK FURNISHED WITH: - FAUCETS - LEVER WASTES PLUMBING ROUGH IN: 0,1/2" HW BALL VALVE & NON SLAM CHECK VALVE 0+16" ©1/2" CW BALL VALVE & NON SLAM CHECK VALVE 0+16" © (2)MV-2, MIXING VALVES 10+48" OD 3/4" TEMPERED WATER HB-2 0+16" FOR DETERGENT PKG. ©E 3/4" TEMPERED WATER HB-2 0+16" FOR SOAP DISPENSER ©F 3" W. THROUGH P-TRAP ..1-PIPING WITHIN WALL SURFACE MOUNTED WASTE MANIFOLD BY CONTRACTOR SINK (E-18) CHANNEL SUPPORTS BETWEEN TRUSSES ROD HANGERS & SPRING VIBRATION ISOLATORS WSG '. DIAGONAL SEISMIC BRACING WHEN REQUIRED. 18718" - SIZE EXHAUST DUCT - AND GRILLE TO MATCH EXHAUST FAN OUTLET INLINE TRANSFER FAN 24724" EXHAUST GRILLE PER PLAN FLOOR BAKERY OVEN EYEBROW HOOD BAKERY OVEN EXHAUST DUCT - SEE DETAIL® v - INSULATED CEILING PANEL 4'MAX .-_- -Z?/ INLINE BAKERY TRANSFER FAN DETAIL SCALE: NONE 24" 24" 2" 24" 150" 2 X, 24° 2" 24° -� 24" --- M.0 TO PROVIDE WARNING PLAN VIEW SIGN READING "CAUTION! SEE DETAIL 140'F HOT WATER" WALL FLASHING SURFACE MOUNTED HOSE BY VENDOR WASTE MANIFOLD BY CONTRACTOR. SINK FURNISHED WITH: - FAUCETS - LEVER WASTES PLUMBING ROUGH IN: 0 1/2"HW BALL VALVE & NON SLAM CHECK VALVE 0+16" 01/2"CW BALL VALVE & NON SLAM CHECK VALVE 0+16" © (2)MV-2, MIXING VALVES 0+48". ©D 3/4" TEMPERED WATER HB-2 0+16" FOR DETERGENT PACKAGE. © E© 3/4" TEMPERED WATER HB-2 0+16" FOR SOAP DISPENSER. ©F 1/2" TEMPERED WATER CONTINUE TO HB-2 NEAR PAN WASHER. ©DIRECT DRAIN 2"W THROUGH P-TRAP. FOUR COMPARTMENT SINK E-22 SCALE: NONE FINISH FLOOR REF. DRAIN SIZE A© D-4 4" B© D-4 4" THREADED ADJUSTABLE HEIGHT OUTLET. SEE TABLE FOR SIZE ©A FLOOR DRAIN D-4 SCALE: NONE /_2X4 BLOCKING IN WALL 1 PIPING WITHIN WALL FLOOR SINK PROVIDE 1" MIN. AIR GAP 1 (.) RIM SET FLUSH -TRAP & ARM SIZE® SINK FURNISHED WITH: GOOSENECK SPOUT KNEE OR FOOT VALVES 1-1/2" WASTE TAILPIECE WALL BRACKET OR PEDESTAL PLUMBING ROUGH IN: © © HAND SINK (E-1, F- 4) SCALE: NONE 1/2"HW WALL STOP 0 +16" 1/2"CW WALL STOP ® +16" 1-1/2" WASTE ® 20" MC TO PROVIDE WATTS USG-B-M1 THERMOSTATIC MIXING VALVE TO REDUCE WATER TEMPERATURE TO 110' F ON ALL HAND SINKS LOCATED IN THE FOOD SERVICE, DELI, MEAT, ROTISSERIE AND BAKERY -PROVIDE PRV CASH ACME MODEL EB-45. SET PRESSURE TO 40 PSI. PROVIDE PRESSURE GAUGE DWYER MODEL #SGB-00521N (0-100 PSI) 3/4" CW FROM NEAREST UNE. 51 3/4" STUB -OUT WALL W/ESCUTCHEON BALL VALVE STRAINER CHECK VALVE 18" X 18" X PLYWOOD BACKING T BEHIND WALL BY MECHANICAL CONTRACTOR. 2X4 BLOCKING IN WALL 1/2„ SINK FURNISHED WITH: GOOSENECK SPOUT, KNEE VALVES, 1-1/2" WASTE TAILPIECE & WALL BRACKET 16" 1/2" 36° 60" 84° P BALL VALVE, STRAINER AND CHECK VALVES PROVIDED WITH UNIT. PLUMBING ROUGH IN: C)1 /2" HW WALL STOP 0+16" ©1/2" CW WALL STOP 0+16" ©1-1/2" WASTE 020" WATER METER E-5/ HAND SINK E-1 SCALE: NONE BALL VALVE (N.C.) FINISHED WALL PROVIDE SIGHT FLOW INDICATOR. M/N: W.E. ANDERSON SFI-100MP SGAS (HWC (SIZE PER PLAN) rSHW CEILING 1" HW TO PAN WASHER 1/2" BALL VALVE BACKFLOW PREVENTER 1/2" WATTS 007QT 1/2" GAS CONNECTION TO PAN WASHER D-6 FLOOR DRAIN. SEE PLAN FOR LOCATION CONTRACTOR TO INSTALL TENANT SUPPLIED HOSE DOWNSTREAM OF BACKFLOW PREVENTER TO HOSE REEL REAR ELEVATION VIEW RACK WASHER (E-6) SCALE: NONE CONCRETE RACK WASHER PIT PER ARCH DRAWINGS. 4"0 THREADED ADJUSTABLE HEIGHT OUTLET. 4" P-TRAP FLOOR DRAIN TYPE D-6 D-6 ANCHOR TAB (TYP.) `SEDIMENT BASKET UTLET STRAINER WITH LOCKING PINS P TRAP & TRAP ARM SCALE: NONE PROVIDE SS BIRD SCREEN AND RAIN CAP AT TERMINATION. TALL CONE ROOF FLASHING, ROOF �-- PENETRATIONS BY M.C. COORDINATE REQUIREMENTS WITH MBS. STEAM VENT, CENTROTHERM, 8"0 50 NOTE: CONTRACTOR TO PROVIDE 12X12 WALL ACCESS PANEL. LOCATION TO MATCH SINK DETAILS. PIPING WITHIN WALL PLUMBING ROUGH WALL ACCESS PANEL ACUDOR #UF-5000-SCS, Q 3/4" HW WALL DETERGENT PKG. -' BY OTHERS MATCH LOCATION WITH SINK DETAILS 1--L-SURFACE 1 MOUNTED I I 12" 1 WALL OE SIDE VIEW WALL ACCESS MIXING VALVE DETAIL (E-18 & E-22) ©e 3/4" CW WALL © MIXING VALVE MV-2 0+48" SCALE: NONE PROVIDE ESCUTCHEONS FOR ALL CEILING PENETRATIONS PROVIDE THRUST BLOC AT END OF P" RUN PER DETAIL DROP PIPE FROM CEILING SPACE WITHIN 6" OF BACK OF WASHER. HOSE REEL, SPRAY NOZZLE AND HOSE HANGER SUPPLIED BY TENANT INSTALLED BY CONTRACTOR FINISHED WALL 90 6" MAX .' SIDE VIEW FAN BASE 1/16" STAINLESS STEEL WIRE ROPE TO ALLOW FAN TO OPEN TO 90' MIN. 40" DISCHARGE PROVIDE HASP WITH COTTER PIN TO SECURE OPEN END OF HINGED FAN (TYP OF 2) SEE SCHEDULE FOR MINIMUM REQUIRED CURB HEIGHT AND SUPPLIER NOTE: GREASE TRAP, HINGE KIT, AND MINIMUM 40" DISCHARGE FROM ROOF DECK FOR UL 762 FANS ONLY. ROOF EXHAUST FAN SCALE: NONE 8"0 STEAM VENT. CENTROTHERM INNOFLUE SINGLE WALL OR SCHEDULE 80 CPVC. PROVIDED BY M.C. METALBESTOS CT RAIN CAP 4"0 FLUE THRU ROOF 4"0 FLUE THRU ROOF OFFSET 10' MIN. FROM PARAPET. LOCATE OFFSET ABOVE CEILING. DUCT CONTINUOUS THRU ROOF W/FLASHING & RAIN CAP. CEILING STEAM VENT FAN. PROVIDE 3/4" TEE SUPPLIED SUPPLIED BY OWNER CAP WITH DRAIN INSTALLED BY M.C. FROM STEAM VENT. MANUFACCTURING pl FVATION VIEW RACK WASHER E-6 SCALE: NONE PROVIDE SUPPORT FOR STEAM VENT FROM ROOF STRUCTURE PROVIDE ESCUTCHEONS FOR ALL CEILING PENETRATIONS P-TRAP DAYLIGHT CONDENSATE DRAIN LINE 2" PW P (1 i CID %-I 0 1--I c 1--1 IN ® SINKS: STOP 0+48" STOP 0+48" NN QD 3/4" TEMPERED WATER HB-2 0+16" FOR SOAP DISPENSER (WASH COMPARTMENT) © 3/4" TEMPERED WATER HB-2 0+16" FOR SOAP DISPENSER (SANITIZING COMPARTMENT) ROOF SIZE PER PLAN BAKERY 4"0 FLUE THRU ROOF. SEE DETAI CEILING NOTE: M.C. TO PROVIDE AND INSTALL ALL: FIXTURES, PIPE, FITTINGS AND VALVES UNLESS OTHERWISE NOTED. CENTRIFUGAL EXHAUST FAN, SEE SCHEDULE FLOATING HINGE VENTED CURB FOR TYPE I HOOD EXHAUST GREASE TROUGH DECK OTHER DETAIL EXTEND DUCT UP TO FAN INLET AND EXTERIOR BASE OF TOP CURB CENTROTHERM COMMERCIAL APPLIANCE ADAPTOR WITH VIBRATION ISOLATION BOOT DRAFT DIVERTER PROVIDED BY OWNER INSTALLED BY M.C. NEL M.C. TO PROVIDE AND INSTALL ALL: FLUE/VENT PIPING COUPLINGS, FITTINGS, SUPPORTS/BRACING ROOF CAPS AND DECK TITES REVIEWED FOR CODE COMPLIANCE 01 City of Tukwila BUILDING DIVISION CITY OF Tin.AILA PERMIT CENTER CHECKED: PKR REVISION DATE: J ISSUE DATE: NOVEMB RENCE NO: 93-0440-36 ARCHITECT 0 1- 0 Z CD X hd 2 1— PROJECT NO:18-688 BAKERY UPGR co in in cy, :OW WOO r.4 CO W • CD GQ LEGEND 0 I ' PL1 FIXTURE TYPE FIXTURE ON EMERGENCY LIGHT CIRCUIT W/BATTERY BACK PACK FLUORESCENT LIGHT FIXTURE SUB -LETTER INDICATES CONTROLLING SWITCH SUB -LETTER INDICATES CONTROLUNG SWITCH, a CONTROLS OUTER LAMP(S) AND b CONTROLS INNER LAMP(S) SINGLE POLE SWITCH, +42" SUB -LETTER INDICATES FIXTURE CONTROLLED, +42" THREE POLE SWITCH, +42" JUNCTION BOX, SIZE AND TYPE PER CODE MOTOR CONNECTION AS REQUIRED DUPLEX RECEPTACLE, +18" OR AS NOTED FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER NON -FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER CONDUIT IN CEILING OR WALL, 1/2" MIN. CONDUIT UNDERGROUND OR FLOOR, 3/4" MIN. HOME RUN TO PANEL WITH CIRCUIT NUMBER, SLASHES INDICATE NUMBER OF CONDUCTOR CN- INDICATES DUITOPVCR OTHERTITHANNDUIt1/2"C ISOLATED GROUND OR GROUND CONDUCTOR GFI GROUND FAULT CIRCUIT INTERRUPTER m. NEW PANEL EXISTING PANEL E.C. ELECTRICAL CONTRACTOR (E) EXISTING m SINGLE PLUG-IN RECEPTACLE, +18" MIN. OR AS NOTED ♦ TELEPHONE / DATA OUTLET WITH 3/4" CONCEALED -IN -WALL CONDUIT TO CEIUNG SPACE OR AS SHOWN. NO DAISY CHAIN WP WEATHER PROOF a 0-1OV OCCUPANCY SENSOR & DIMMING SWITCH LUTRON MS-Z101-IV. NOTE: SET TO 20-MINUTES DELAY. PROVIDE LOW VOLTAGE WIRING TO EACH FIXTURE. MAKE ALL FINAL CONNECTIONS AS REQUIRED. FIELD VERIFY. DC DROP CORD ELECTRICAL DEMOLITION GENERAL NOTES ELECTRICAL CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DEMOLITION PLANS FOR THE SCOPE OF CORRESPONDING BUILDING DEMOLITION WORK. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND TO WORK. REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING BACK TO THE NEXT ACTIVE OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED. REMOVE OR ABANDON ALL UNUSED UNDERGROUND, UNDER FLOOR RACEWAYS. REMOVE ALL UNUSED SURFACE RACEWAYS. RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW LOCATION, PROVIDE NEW CONNECTION AS REQUIRED. PROVIDE CUTTING, PATCHING, TRENCHING AND BACK FILL FOR ALL RELATED ELECTRICAL WORK AS REQUIRED. ALL REMODEL WORK SHALL BE PERFORMED NOT TO INTERFERE WITH WAREHOUSE'S NORMAL OPERATION, COORDINATE AND SCHEDULE WITH WAREHOUSE, ARCHITECT FOR WORK SCHEDULE. PERFORM WORK DURING OFF BUSINESS HOURS AS REQUIRED. COORDINATE AND SCHEDULE WITH WAREHOUSE FOR ANY EXISTING ELECTRICAL SERVICE SHUT DOWN, PROVIDE TEMPORARY POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR WAREHOUSE'S NORMAL OPERATION AS REQUIRED. EXHAUST FAN ROOF LINE OVEN POWER Y IN NEMA-1 ENCLOSURE CONTROL PANEL E.C. INSTALL & MAKE FINAL CONNECTIONS. FINAL CONNECTIONS AT CONTROL PANEL BY E.C. UNDER THE DIRECTION OF THE EQUIPMENT MANUFACTURER. OVEN WIRING DIAGRAM NO SCALE ELECTRICAL - PLAN NOTES: Oj E.C. TO REMOVE ELECTRICAL DEVICES, CONDUITS, WIRES IN DEMO AREA (SEE ARCHITECTURAL PLAN) TO SOURCE. PROVIDE "SPARE" LABEL AND TURN BREAKERS TO "OFF" POSITION. EXTEND EXISTING FEEDERS FOR CONTINUITY AS REQUIRED. 02 EXISTING OVENS TO BE REPLACED. E.C. TO DISCONNECT AND RECONNECT POWER FROM EXISTING OVENS TO NEW OVENS, EXTEND EXISTING FEEDER AS REQUIRED. E.C. TO VERIFY EXISTING OVEN FEEDER AND BREAKER IF IT IS MINIMUM OF 5#12 CU IN 3/4"C AND 20A/3P BREAKER; IF NOT THEN REPLACE WITH 5#10 CU AND 20A/3P BREAKER. REUSE EXISTING CIRCUIT. E.C. TO REPLACE EXISTING OVEN RELAY IF REQUIRED. FIELD VERIFY. SEE DETAILS 1. O EXISTING EXHAUST FANS TO BE REMOVED & REPLACED. E.C. TO DISCONNECT POWER AND RECONNECT POWER TO NEW FAN. REUSE EXISTING CIRCUIT. FIELD VERIFY. SEE DETAIL 2A. EXISTING ROOF RECEPTACLE TO REMAIN, RELOCATE IF REQUIRED. © E.C. TO REUSE (2) EXISTING 20A/1P BREAKERS IN EXISTING PANEL P5 FOR NEW EXHAUST FANS AND RECEPTACLES. FIELD VERIFY. 05 E.C. MAKE ALL FINAL CONNECTIONS FOR BAKERY TRANSFER FAN CONTROL. SEE DETAIL 3 THIS SHEET. PROVIDE JOHNSON CONTROLS CSD-CF0J1-1 CURRENT DEVICE AND SQ-D CLASS 9070 TF50D23 STEP-DOWN TRANSFORMER IN NEMA-1 ENCLOSURE, PRIMARY DISCONNECT, PRIMARY AND SECONDARY FUSING (FB3A FOLDER, 0.4A PRIMARY FUSES, 0.7A SECONDARY FUSES) AND ALL LOW VOLTAGE WIRING. MOUNT ENCLOSURE NEAR PANEL P13. TYP OF 4. E.C. HAS OPTION TO USE CONTACTOR IN OVEN THAT CONTROLS THE FAN DUCTED TO OVEN TO CONTROL THE FAN(S) IN FRONT OF THE OVEN IF THERE IS AVAILABLE SPACE IN THE CONTACTOR AND THE CONTACTOR IS PROPERLY RATED. E.C. TO REUSE (2) EXISTING 20A/1P BREAKERS IN P5 & (2) EXISTING 20A/1P BREAKERS IN P13 FOR NEW FANS. FIELD VERIFY. © EXISTING CEILING GRIDS TO BE REPLACED. E.C. TO DISCONNECT & RECONNECT POWER FROM EXISTING LIGHT FIXTURES AND DROP CORDS. FIELD VERIFY. 07 EXISTING PROOFER TO BE REPLACED. E.C. TO REMOVE EXISTING FEEDER TO SOURCE. PROVIDE NEW FEEDER AS SHOWN. REUSE EXISTING CIRCUIT. E.C. TO REPLACE EXISTING BREAKER WITH NEW 45A/3P BREAKER. FIELD VERIFY. EXISTING RACK WASHER TO BE REPLACED. E.C. TO REMOVE EXISTING ELECTRICAL DEVICES AND ASSOCIATED FEEDER TO SOURCE. TURN OFF BREAKER AND PROVIDE 'SPARE' LABEL. E.C. TO PROVIDE (1) 50A/3P BREAKER IN EXISTING PANEL H3 AND NEW FEEDER AS SHOWN. REMOVE AND RELOCATE LIGHT FIXTURES AS REQUIRED. FIELD VERIFY. • E.C. TO HARDWIRE FEEDER FOR RACK WASHER FROM DISCONNECT UP TO CEILING AND DROPPED TO RACK WASHER. PROVIDE CONDUIT SUPPORT PER CODE. ALLOW MINIMUM OF 3' CLEARANCE IN FRONT OF DISCONNECT SWITCH. E.C. TO MAKE FINAL CONNECTIONS TO RACK WASHER'S STEAM EXHAUST FAN. • E.C. TO REMOVE AND RELOCATE EXISTING DROP CORDS TO NEW LOCATION AS SHOWN. EXTEND EXISTING FEEDER TO NEW LOCATION AND REPULL WIRES AS REQUIRED. FIELD VERIFY. © E.C. TO PROVIDE NEW LIGHT SWITCHES AS SHOWN. REWIRE EXISTING LIGHT FIXTURES TO BE CONTROLLED BY NEW SWITCHES IN THIS SPACE. RELOCATE EXISTING LIGHT FIXTURES AND REPULL WIRES AS REQUIRED. FIELD VERIFY. © E.C. TO MAKE FINAL CONNECTION TO PROOFER LIGHT. © E.C. TO REMOVE AND RELOCATE EXISTING EMERGENCY UGHT FIXTURE TO NEW LOCATION AS SHOWN. EXTEND EXISTING FEEDER TO NEW LOCATION AND REPULL WIRES AS REQUIRED. FIELD VERIFY. ® E.C. TO PROVIDE (1) 20A/3P BREAKER IN EXISTING PANEL P3 FOR FUTURE OVEN AND (1) 20A/1P BREAKER IN EXISTING PANEL P5 FOR FUTURE EXHAUST FAN. FIELD VERIFY. E.C. TO PROVDE & INSTALL MARK TIMER IN SINGLE GANG BOX TO CONTROL EXHAUST FAN. MANUFACTURER: INTERMATIC. MODEL#: FF12HC. TYPICALLY. 0 ELECTRICAL GENERAL NOTES FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND TO WORK. REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING BACK TO THE NEXT ACTNE OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED. RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW LOCATION, PROVIDE NEW CONNECTION AS REQUIRED. PROVIDE CUTTING, PATCHING, TRENCHING AND BACK FILL FOR ALL RELATED ELECTRICAL WORK AS REQUIRED. ALL REMODEL WORK SHALL BE PERFORMED NOT TO INTERFERE WITH WAREHOUSE'S NORMAL OPERATION, COORDINATE AND SCHEDULE WITH OWNER, ARCHITECT FOR WORK SCHEDULE. PERFORM WORK DURING OFF BUSINESS HOURS AS REQUIRED. COORDINATE AND SCHEDULE WITH WAREHOUSE FOR ANY EXISTING ELECTRICAL SERVICE SHUT DOWN, PROVIDE TEMPORARY POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR WAREHOUSE'S NORMAL OPERATION AS REQUIRED. APPLICABLE CODE: LATEST CSA & LOCAL AMENDMENT. FLEXIBLE METALIC LIQUIDTIGHT CONDUIT WITH SLACK FOR HINGED SUB -BASE ROOF PENETRATION BY EC. COORDINATE REQUIREMENT WITH ROOF INSTALLER. HINGE 2A CONDUIT TO EXHAUST FAN DETAIL NO SCALE P6/_ P6/_ N 120/24VAC P/S JC CSD SENSOR/ CONTACTOR NEMA 1 ENCLOSURE BAKERY OVEN KEF-X KTF-X BAKERY KTF CONTROL DETAIL. TYP.O NO SCALE BAKERY DEPARTMENT EQUIPMENT NUMBER: DESCRIPTION* REMARKS: 20 LVO RACK WASHER 480V, 30, 35.6A 60A/30 W/ 50AF DISCONNECT SWITCH. 480V/30/4W +48" A.F.F. SEE NOTE 09 0 HOBART PW3S-SEFAAA PROOFBOX 208V, 30, 35.5 FLA 60A/30 DISCONNECT SWITCH W/45 AF +84" A.F.F. JUNCTION BOX FOR FUTURE OVEN POWER, 0 03P3 4 P5/410 I ) KTF-1i u KTF-1 �10 KTF-1 010 CONTROLLER® CONTROLLER® CONTROLLER PC103111VOLT-ElIFRTD H3/28 #4, 1-1/4"C P5/7® OSTAT FO MOUNT 0 +48" A.F.F. LABEL "EXHAUST FAN". (� d P5/5 ® N,P146, #10 BAKERY ENLARGED PLAN SCALE 1/8" = r-o" FOR WORK IN THIS AfiEA, SEE ENLARGED BAKERY PLAN ON THIS SHEET. KEF-22 ON ROOF. VERIFY LOCATION WITH M.C. SEE DETAIL 2B. TF-1 ABOVE CEILING/BELOW ROOF. VERIFY EXACT LOCATION W/M.C. "I• EXISTING PANELS IN FRONT / ELEC ROOM. PARTIAL FLOOR PLAN SCALE: 1/16" = 1'-0" F City of Tukwila BUILDING DIVISION j RECEIVE- CITY OF TUK:1+IL. SEP 2 6 2019 PFRIJIIT (CS.-:; ER OWNER REVISIONS z 1-1 z di h-1 Q 0) 0 w 124 'Q± 0 0 1-4 a. W SEPTEMBER 11, 2019 REVISION DA N ISSUE DATE: N ARCHITECT REFERENCE NO: 93-0440-36 J x z zw 1- ow ao oz w cc (/' 00 w 0 nz CO a M0 o w _ 0 Dw 0I- 05 rn 0 r3 0 o� •Ca a? 0 CC zo 0 PROJECT NO:18-688 y014 05 Qr Pjg 0 0 w 0) 1n rn OWNER REVISI PERMIT RESUBMUTTAL rn 0) o o m N 8 U BAKERY UPGRADE �wCO ›. CO o04c0 Q41 OJ Cn UO Syr CD P4 O d' E-1