Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M19-0176 - DERMODY OXBOW - HVAC INSTALLATION FOR NEW TILT-UP CONCRETE BUILDING
DERMODY OXBOW 10500 W MARGINAL PL S Apn: 0423049150 FINALED 04/15/2021 M19-0176 Parcel No: Address: ��^�xx ^�� Tukwila *~U~� uvn . ��nxw�Uva Department ofCommunity Development 6300SowthcenterBoulevard, Suite #10O Tukwila, Washington 9gl88 Phone: 206'431'3670 Inspection Request Une:IO6-438'93S0 VVebxite:http://www.Tukm/iiaVVA.gox MECHANICAL PERMIT 0423049150 Permit Number: M19-0176 Project Name: DERMODY OXBOW Issue Date: 6/22/2020 Permit Expires On: 12/19/2020 Owner: Contact Person: Name: Address: DE5|K40NETRUST OXBOW Z601 lZ0lTHIRD AVE STE#50l0C/O DNY MELLONNA, SEATTLE'WA, 98l01 T0DD3CHUTZ Phone: (206)4088645 lZ0OF|FTHAVE'5V|TE13OO. �mm�� Name: [VERGKBNREFRIGERATION LL[ Phone: (I06)763'I744 <CON�� Address: 7275KENYONST'SEATTLE,VVA 98108 Expiration Date: 1/6/2022 l20OF|FTHAVE'5V|TE13OO. License No: EVERGRL954R2 Lender: Name: ^'' DESCRIPTION OF WORK: NEW MECHANICAL/HVAC INSTALLATION FOR NEW 352,087 SF TILT -UP CONCRETE BUILDING WITH 10,121 SF OF ACCESSORY OFFICE SPACE, THERE IS A 2ND FLOOR, UN -OCCUPIED WORK PLATFORM CONTAINING PACKAGE HANDLING EQUIPMENT AND CONVEYORS, THE BUILDING IS FULLY SPRINKLED WITH AN ESFR SPRINKLER SYSTEM. Valuation of Work: $0.00 Type of Work: Fveitype: Fees Collected: $17,679.45 Electrical Service Provided by: S[ATrLECITY LIGHT Water District: TUKVV|U\ Current Codes adopted hythe City wfTukwila; International Building Code Edition: International Residential Code Edition:2015 International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[29646D: WA State Energy Code: 20172017 2015 017 , Permit Center Authorized Signature�- I hearby certify that I have read and examined this permit and know the same to be true and correct.All pnmisionsof|awandordinancesgoverningthiseorkvvU|becomp|iedwith,whetherspedfiedhereinornot. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance mfwork, |amauthorized tosign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Co//0_/� � �/o This permit shall become null and void ifthe work bnot commenced within 18Odays for the date ofissuance, o,if the work is suspended or abandoned for a period of 180 days frorn the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall hekept atthe site ofwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. l Readily accessible access turoof mounted equipment is required, 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. S: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (206'431'367O), 6-. All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OFPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila, Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ufapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS' 9: All mechanical work shall be inspected and approved urder a separate permit issued by the City of Tukwila Permit Centcr(206/4}1'367O). 10: Manufacturers installation instructions shall beavailable onthe job site atthe time nfinspection. ll: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U,L. central station supervision is required. (City Ordinance #I437) 13: H.V,A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall beequipped with anautomatic shutoff. Automatic shutoff shall heaccomplished byinterrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (|MC6O6.I'5O6Zl) 14: Remote indicator lights are required onall above ceiling smoke detectors. (City Ordinance #Z4J7) 15: Duct detectors shall send asupervisory signal only upon activation. (City Ordinance #Z437> 16: All new fire alarm systems or modifications to existing systems shall have the written approvalof The Tukwila Fire Prevention Bureau, Nowork shall commence until afire department permit has been obtained. (City Ordinance #24J7)(IF[9Ol.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #24J7) 19� Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ofsuch condition orviolation. 20; These plans were reviewed byInspector S11. Ifyou have any questions, please call Tukwila Fire Prevention Bureau at(ZU6)575'4407. PERMIT INSPECTIONS REQUIRED Permit Inspection, Line: (2O6)43B9]5O 1400 FIRE FINAL 0703 K4ECH EQU|PEFF 1800 MECHANICAL FINAL 0609 P|PE/DUCT|NSUUT0N 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:i www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review, Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 042304-9150, 042304-9011, 042304-9073, Site Address: 10500 W. Marginal Place King Co Assessor's Tax No.:042304-9001, 042304-9195 S. Suite Number: N/A Floor: N/A Tenant Name: N/A PROPERTY OWNER Name: DPIF2 WA 6 OXBOW, LLC Address: 5500 Equity Avenue City: Reno State: NV Zip: 89502 CONTACT PERSON — persn a receiving all project comnication Name: Nelson Worldwide Address: 1200 Fifth Avenue, Suite 1300 City: Seattle State: WA Zip: 98101 Phone: (206) 408-8645 Fax: Email: tschutz@nelsonww.com New Tenant: D Yes 0..No MECHANICAL, CONTRACTOR INFORMATION Company Name: TBD 6eltgA.Lit Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1,764,000 Describe the scope of work in detail: Construction of a new 352,087 sf tilt -up concrete building with 10,121 sf of accessory office space. There is a second floor, un- occupied work platform containing package handling equipment and conveyors. The building is fully sprinkled with ESFR sprinkler system. Use: Residential: New 0 Replacement Commercial: New Replacement El Fuel Type: Electric II Gas Other: ApplicationsWorms-Applications On Line \2016 Applicationatechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 2 Furnace >100k btu 10 Floor furnace 0 Suspended/wall/floor mounted heater 5 Appliance vent 0 Repair or addition to heat/refrig/cooling system 0 Air handling unit <10,000 cfrn 12 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler 0 Ventilation fan connected to single duct 8 Ventilation system 15 Hood and duct 0 Incinerator — domestic 0 Incinerator— comm/industrial 0 Unit Type Qty Fire damper 0 Diffuser 51 Thermostat 12 Wood/gas stove 0 Emergency generator 0 Other mechanical equipment 0 Boiler/Compressor Qty 0-3 hp/100,000 btu 0 3-15 hp/500,000 btu 0 15-30 hp/1,000,000 btu 0 30-50 hp/1,750,000 btu 0 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, it' sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sourtd Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-I OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); Testing of backup generators during the day. PERMIT APPLICATIONNOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within l80 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING OWNER OR AUTHORIZED AGENT: Signature: Lee.4 geAdte. Date: 10-15-19 Print Name: Lou Berchicci Day Telephone: 224-567-8842 x304 Mailing Address: 2860 S. River Road, Ste. 480 Des Plaines, IL 60018 City State Zip H: Applications Forms -Applications Or Line,20I6 Applications Mechanical Permit Application Revised I -4-16.ducv Revised: January 2016 bh Page 2 of 2 DESCRIPTIONS .PermitTRAF Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 9=01' 500 W MARGIN7 n: 04230491 4 Credit Card Fee 418.25 Credit Card Fee R000.369.908.00.00 0.00 $418.25 MECHANICAL $13,277.85 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $13,244.70 TECHNOLOGY FEE $663.89 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R20871 R000.322.900.04.00 0.00 $663.89 $14,359.99 Date Paid: Thursday, June 04, 2020 Paid By: ADMINISTRATIVE CARD Pay Method: CREDIT CARD 062332 Printed: Thursday. June 04. 2020 10:16 AM 1 of 1 m w Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 06/04/2020 10:15:37 AM CREDIT CARD SALE VISA CARD NUMBER: **********3160 K TOTAL AMOUNT: $14,359.99 APPROVAL CD: 062332 RECORD #: 000 CLERK ID: Elisa I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy httnQ•//urcxnai rnnvarcrPnav 0nm/rnnvP1.(TP_117Phann/ A/a/')m n DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila au!. 4.4741,: ACCOUNT 0).1: QUANTITY PAID 4 - $9,647.22 , EL19-0852 Address: 10500 W MARGINAL PL S BLDG 9-150 Apn: 0423049150, - $5 834 88 ELECTRICAL $5,834.88 PLAN CHECK FEE R000.345.832.00.00 0.00 $5,834.88 , M19-0176 - 9-150 Ai 0423049150 3,319.46 MECHANICAL $3,319.46 PLAN CHECK FEE R000.322.102.00.00 0.00 $3,319.46 PG19-0158 Address: 10500 W MARGINAL PL S BLDG 9-15 pn: 0423049150,„ 49188,7 GAS $55.75 PLAN CHECK FEE R000.322.103.00.00 0.00 $55.75 PLUMBING $437.13 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R18851 R000.322.103.00.00 0.00 $437.13 $9,647.22 Date Paid: Thursday, October 17, 2019 Paid By: DP INDUSTRIAL FUND REIT III LL Pay Method: CHECK 30000371 Printed: Thursday, October 17, 2019 4:02 PM 1 of 1 CRWY STEMS Permit Inspections City of Tukwila Permit Number: M19-0176 Description: DERMODY OXBOW Applied: 10/17/2019 Approved: 5/20/2020 Issued: 6/22/2020 Finaled: 4/15/2021 Status: FINALED Parent Permit: Parent Project: Details: Site Address: 10500 W MARGINAL PL S City, State Zip Code:TUKWILA, WA 98168 Applicant: DERMODY OXBOW Owner: DESIMONE TRUST OXBOW 2601 Contractor: EVERGREEN REFRIGERATION LLC (CONST) NEW MECHANICAL/HVAC INSTALLATION FOR NEW 352,087 SF TILT -UP CONCRETE BUILDING WITH 10,121 SF OF ACCESSORY OFFICE SPACE. THERE IS A 2ND FLOOR, UN -OCCUPIED WORK PLATFORM CONTAINING PACKAGE HANDLING EQUIPMENT AND CONVEYORS. THE BUILDING IS FULLY SPRINKLED WITH AN ESFR SPRINKLER SYSTEM. IIINIZgi INSPEGTIONS SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS MECH EQUIP EFF Bill Centen Notes: PIPE_DUCT INSULATION Bill Centen 509-264-1494 Notes: ROUGH -IN MECHANICAL Bill Centen Notes: MECHANICAL FINAL Bill Centen 509-264-1494 Notes: REFRIGERATION EQUIP Bill Centen Notes: LFIRE ALARM Ben Hayman Notes: FIRE FINAL Ben Hayman Notes: Printed: Tuesday, 19 October, 2021 1 of 2 SUPERION Permit Inspections City of Tukwila 1/28/2021 AM 1/28/2021 PIPE DUCT — INSULATION Bill Centen NOT APPROVED 509-264-1494 Notes: 1. Not ready 1/28/2021 1/28/2021 ROUGH -IN MECHANICAL Bill Centen PARTIAL APPROVAL Notes: *Ok to insulate ducts. Call for inspection when ready 2/23/2021 AM 2/23/2021 MECH EQUIP EFF Bill Centen CANCELLED 509-264-1494 for gas pressure test inspe Notes: See rough in Gas piping inspection 2/24/2021 2/23/2021 ROUGH -IN GAS PIPING Bill Centen APPROVED Notes: Inspected new gas piping for all Roof top units and Gas HWT. Pressure test is at 20 psi - ok 3/22/2021 AM 3/22/2021 MECH EQUIP EFF Bill Centen CANCELLED Notes: 3/23/2021 3/23/2021 ROUGH -IN MECHANICAL Bill Centen PARTIAL APPROVAL Flex duct to Diffusers/Cover approval Notes: Inspected flex drops to Diffusers at the following area: *From R - S Line & from 1 4.4 - ok 3/24/2021 AM 3/23/2021 PIPE DUCT _ INSULATION Bill Centen PARTIAL APPROVAL 509-264-1494 Notes: Duct insualtion is approved between the following frid lines: *Ft - $ Line and from 1- 4.4 line - ok 4/8/2021 AM 4/8/2021 SMOKE DETECTOR TEST Bill Centen APPROVED 509-264-1494 Notes: 4/8/2021 AM 4/8/2021 MECHANICAL FINAL Bill Centen NOT APPROVED 509-264-1494 Notes: 1. Need Fire Final approval 2. Need Fire Alarm approval 3. Label all RTU Units on underneath side 4/15/2021 4/15/2021 MECHANICAL FINAL Lee Sipe APPROVED Notes: Printed: Tuesday, 19 October, 2021 2 of 2 .(*••• rk SUPERION l[E.|nc. 83ONRiverside Dr. Suite ZOO Renton, VVA98O57 Phone: 425'97O']753/Fax: 425'97O'3756 RE: Dernnody—Oxbovv Tukwila, WA Energy Code Compliance ��_` . __^ ' '^ '^— V.— .��R ����_ �� _ , rf � — ��=� ��� '' �iANC� J������^ 3� — ^^^^"~~��k��~ ������MY0 ~~^~~~�w/� CitY Of Tukwila BUILDING DIVISION 17 RECE|V—D CITY OFTU�WUA OCT� J �M�� ���"/ ' v �w^� PERMIT CENTER Building Simulation Executive Summary: For the proposed building atthe referenced location, energy simulations were performed to document compliance with the 2015 Washington State Energy Code (Chapter 51-11C WAC). The proposed building design was simulated to use I5.1Y6 less annual site energy than the standard reference design thus meeting the requirement for performance -based compliance as defined inSection [4O73. Simulation Software: For the building at the above mentioned address, simulations were completed usinge[}uest 3.65 software which utilizes DOE'22 and has been tested in accordance with A3HRAEStandard 140. This simulation program satisfies all simulation general requirements outlined in Section C407.6 Calculation software tools. Simulation Parameters: The following section outlines compliance of the simulation model for calculating the proposed and reference building performance in accordance with the requirements in Table C407.5.1(1), Specifications for the Standard Reference and Proposed Designs Proposed Building Design Reference Building Design Space Use Classification ° Warehouse—StoraXearea • Office (open p|an) ~ Restnoonn(othenwise) * Conference ° Same asproposed Roofs 0 Insulation entirely above deck: U-0.028 ° Insulation entirely above deck: U'0.023 ~ Gross area: Same asproposed Walls, above -grade ° Mass: U-0.07Oexcept E-S-Wwarehouse walls "pu»1Dft. noinsulation. ^ Solar abannptanco:O.75 ° Enoittance:0.90 Walls, below -grade ° Mass: U-0i078 ° Gross area: Same asproposed ° 9olaraba/rpmnoe: Same asproposed ° snnauonce: Same asproposed Demnody—Oxbow Floors, above -grade Floors, slab -on -grade ° Same asproposed Opaque Doors * Swinging: • ° DM Roll -up: ' ° Swinging: Same asproposed ~ Roll -up: Same aoproposed Vertical Fenestration ° Area: less than 3O%wall area ° Metal-Fixed:U'O.]8 ° Meta I-OperaWe:V-l4U • Metal'Entrance:U-l6O ° 5HGC:O.B * Shading and PF: None 0 Same as proposed Skylights Lighting, interior ° Actual per electrical ° Space -by -Space Method: Maximum per Table Lighting, exterior ° Exterior Lighting: Actual per electrical * Site Lighting: Actual per electrical ° Exterior Lighting: Maximum per Table C405.62(l) • Site Lighting: Maximum per Table C405.6.2(2) Internal gains ° Receptacle, motor and process loads modeled based onspace use ° All end -use load components within and associated with the building modeled 0 Same as proposed * Same as proposed Schedules ° Hourly profiles for all schedules and determined from estimated building use Same as proposed Mechanical ventilation ° Minimum outdoor air per Chapter 4of International Mechanical Code Same asproposed Heating systems ° Fuel: Fossil &electric ° Equipment: Actual per mechanical ° Efficiency: Actual per manufacturers' spec • Capacity: Actual per mechanical Cooling sv,tw,ns 0 Fuel: Direct expansion • Equipment: Actual per mechanical ° Efficiency: Actual per manufacturers' spec ° Capacity: Actual per mechanical ° Economizer: All systems fixed dry-bulb @ 75^F ° Fuel: Same asproposed ° Equipment: Same a,proposed ° Efficiency: Minimum per Table [40].2.3<4> • Capacity: Same as proposed ° Fuel: Same aoproposed • Equipment: Same asproposed ° Efficiency: Minimum per Table C4032.3(l) ° Capacity: Same a`proposed ° Economizer: Same asproposed Energy recovery � Per section C403.2/5 o Service water heating o Space heating ° Same asproposed Fan systems ° Airflow: Svpply-tononnndelta cf 20'F • Motor brake horsepower: Actual per ° Airflow: Same asproposed ° motor brake horsepower: Per section _41nLTo_n1 Dannooy—Oxbnw manufacturers' spec [4O3l1Owhere appiivab|e. Otherwise, same as proposed. Shading from adjacent structures/terrain * Shading byadjacent st/cture/tenain:None * Shading bypermanent fixture: None ° Same asproposed Service water heating * Fuel: Fossil &ehctrio ° Efficiency: Actual per manufacturers' spec * Capacity: Demand based onoccupancy schedule Documentation of simulated performance: * Fuel: Same ao`noposedEfficiency:° Efficiency: Miimmmp~r *b-e ' - Z ° Capacity: Same asproposed Annual Energy Consumption Summary Reference Proposed Y6Improvement Electricity (mBtu) Natural Gas (mBtu) 5.4127 1277 4.283.5 4172 20.096 '226796 Total Site (mBtu) 5.540.4 4.7007 15.1% Energy saving measures implemented: The proposed building utilizes the following additional efficiency package options per section [4O6toreduce site energy consumption: * Reduced lighting power inaccordance with Section [4O6.3 ^ Reduced air infiltration inaccordance with Section [406.4 Simulation reports Appendix A: * Proposed Building Simulation Report o Monthly energy consumption bvend use o 8FPS m BEPU o ES-D o SV-A Appandix0z 0 Reference Building Simulation Result o Monthly energy consumption byend use o BEPS o BEPU • ES-D o SV-A o LV'D _*1nLT*_o1 Dermody — Oxbow Simulation Performance Cooling Toads not met Heating Toads not met Baseline Proposed 51 0 . 44 0 Compliance Result The design detailed in the above referenced plans complies with the requirements of the 2015 Washington State Energy Code (Chapter 51-11C WAC) and the Proposed Building energy consumption does not exceed the corresponding Reference Building energy consumption. Therefore, this design DOES COMPLY with the 2015 Washington State Energy Code Total Building Performance methodology. Individual certifying authenticity of the data provided in this analysis: Paal Ryan, P.E., _413LTR_O1 Dennody—Oxbow T.E.� Inc.0 Pl1654APEGAPERMIT TOPRACTICE 83ONRiverside Dr. Suite30O Renton, VVA98US7 Phone: 4Z5-970'37S3/FAX: 42S'978'3756 Appendix A Proposed Building Simulation Reports o Monthly energy consumption byend use o BEPS o BEPU o ES-D o SV-A u LV-D _*1aLTn_n/ Project/Run: Dermody DWA2 - Tukwila, WA - 2 Run Date/Time: 09/25/19 © 17:58 (x000) 150 100 50 0 Electric Consumption (kWh) Jan Feb Mar Apr MayJun Jul Aug Sep Oct Nov Dec ri Area Lighting El Exterior Usage MI Task Lighting • Pumps & Aux. • Misc. Equipment M Ventilation Fans Electric Consumption (kWh x000) • Space Co& 0.0 Heat Reject, Refrigeration Space Heat HP Supp. Hot Water Vent, Fans Pumps & Aux. Ext. Usage Misc. Equip. Task Lights Area Lights 'Total 0.0 0.2 0.9 (x000,000) 150 100 0 0 Gas Consumption (Btu) Jan Feb Mar Apr MayJun Jul Aug Sep Oct Nov Dec Water Heating • Ht Pump Supp. • Space Heating 2.3 El Refrigeration 1111 Heat Rejection • Space Cooling YiT Lug Wov - rola ' 6.0 6.0 3.6 0.3 0.0 19.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 3.3 4.0 3.1 3.4 3.2 3.3 3.2 3.3 3.3 3.2 3.3 3.3 3.9 40.4 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.2 1.4 - - . 71.1 64.2 71.1 68.8 71.1 68.8 71.1 71.1 68.8 71.1 68.8 71.1 836.7 - - - - 30.0 27.1 30.0 291 30.0 29.1 30,0 30.0 29.1 30.0 29.1 30.0 353.0 105,7 103.6 3.14.1 130,7 104,9 105,0 MA 105.6 1255.4 - _ . 94.9 105.,1 -4,944 Gas Consumption (Btu x000,000) $in fob 'VW Space Cool Heat Reject. Refrigeration - - - Space Heat 138.84 44.38 41.31 5.04 0.01 0.S3 30.56 132.86 393.53 HP Supp. - - - Hot Water 2.23 2.02 2.22 2.08 1.98 1.82 1.79 1.75 1.73 1.89 2.00 2.17 23.68 Vent. Fans - - - Pumps & Aux. Ext. Usage Misc. Equip. - Task Lights Area Lights - /Total 141.07 - 46.40 43.53 7.12 1.99 '' 1.82 19 1.75 1,73 2,43 ... 13501 43724 eQUEST 3.65.7175 Monthly Energy Consumption by Enduse Page 1 New Section 2 Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- REPS Building Energy Performance WEATHER FILE- Seattle WA TMY2 TASK MISC SPACE SPACE HEAT PUMPS VENT REFRIG HT PUMP DOMEST EXT LIGHTS LIGHTS EQUIP HEATING COOLING REJECT 6 AUX FANS DISPLAY SUPPLEM HOT WTR USAGE TOTAL EM1 ELECTRICITY MBTU 1207.0 0,0 2856.0 0.0 65.8 0.0 4.9 137.8 0.0 0.0 12.1 0.0 4283.5 FM1 NATURAL-GAS MBTU 0.0 0.0 0.0 393.5 0.0 0,0 0.0 0.0 0.0 0.0 23.7 0.0 417.2 MBTU 1207.0 0.0 2856.0 393.5 65.8 0.0 4.9 137,8 0.0 0.0 35.8 0.0 4700.7 TOTAL SITE ENERGY 4700.74 MBTU TOTAL SOURCE ENERGY 13267.80 MBTU 23.2 [BTU/SQFT-YR GROSS -AREA 23.2 KBTU/SQFT-YR NET -AREA 65.5 KBTU/SQFT-YR GROSS -AREA 65.5 KBTU/SQFT-YR NET -AREA PERCENT OF HOURS ANY SYSTEM ZONE OUTSIDE OF THROTTLING RANGE = 0.93 PERCENT OF HOURS ANY PLANT LOAD NOT SATISFIED = 0.00 HOURS ANY ZONE ABOVE COOLING THROTTLING RANGE = 44 HOURS ANY ZONE BELOW HEATING THROTTLING RANGE - 0 NOTE: ENERGY IS APPORTIONED HOURLY TO ALL END -USE CATEGORIES. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- BEPU Building Utility Performance WEATHER FILE- Seattle WA TMY2 TASK MISC SPACE SPACE HEAT PUMPS VENT REFRIG HT PUMP DOMEST EXT LIGHTS LIGHTS EQUIP HEATING COOLING REJECT 6 AUX FANS DISPLAY SUPPLEM HOT WTR USAGE TOTAL EM1 ELECTRICITY KWH 353760. 0. 836671. 19289, 0. 1439. 40378. 0. 0. 3536. 0, 1255071. FM1 NATURAL-GAS THERM 0. 0. 0. 3935. 0. 0. 0. 0. 0. 0. 237. 0. 4172. TOTAL ELECTRICITY 1255071. KWH TOTAL NATURAL-GAS 4172. THERM 6.199 KWH /SQFT-YR GROSS -AREA 6.199 KWH /SQFT-YR NET -AREA 0.021 THERM /SQFT-YR GROSS -AREA 0.021 THERM /SQFT-YR NET -AREA PERCENT OF HOURS ANY SYSTEM ZONE OUTSIDE OF THROTTLING RANGE = 0.93 PERCENT OF HOURS ANY PLANT LOAD NOT SATISFIED = 0.00 HOURS ANY ZONE ABOVE COOLING THROTTLING RANGE = 44 HOURS ANY ZONE BELOW HEATING THROTTLING RANGE 0 NOTE: ENERGY IS APPORTIONED HOURLY TO ALL END -USE CATEGORIES. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- ES-D Energy Cost Summary WEATHER FILE- Seattle WA TMY2 UTILITY -RATE METERED TOTAL VIRTUAL ENERGY CHARGE RATE RATE USED RESOURCE METERS UNITS/YR (5) IS/UNIT) ALL YEAR? PSE Elec 26 Com/Ind Lrg Demand ELECTRICITY EM1 1255071.. KWH 96368. 0.0768 YES PSE Gas 41 Lrg NRes (>500 therm) NATURAL-GAS FM1 4172. THERM 4829. 1.1575 YES 101197. ENERGY COST/GROSS BLDG AREA: 0.50 ENERGY COST/NET BLDG AREA: 0.50 Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58;05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-1 (PSZ) (G.ENE2) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMS' SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SOFT ) PEOPLE RATIO (KBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) PSZ 1.000 1759.4 25. 0.055 55.000 0.764 -60.000 0.266 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 2300. 1.00 0.255 0.34 0.5 0.53 0.55 BLOW-THRU SPEED 1,10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Offices (fG,z2) 2300. 0. 0.000 1.000 126. 0,00 0.00 41.03 0,00 -54.61 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BOL RUN 5 REPORT- SV-A System Design Parameters for AC-263 (PSZ) (G.N3) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (KBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) PSZ 1.000 7596.2 69. 0.025 300,000 0.753-400.000 0.282 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 18400. 1.00 2.037 0.34 0.5 0.53 0.55 BLOW-TRRU SPEED 1.10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/HR) (KHTU/NR) (KBTU/HR) MULT Break Room (fG.z3) 18400. 0. 0.000 1.000 456. 0.00 0.00 207.09 0.00-383.65 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-4 (PSZ) (G.N4) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (KBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) PSZ 1.000 988.6 40. 0.287 36.000 0.750 -60.000 0.268 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 1380. 1.00 0.153 0.34 0.5 0.53 0.55 BLOW-THRU SPEED 1,10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Training Room (fG.z4) 1380. O. 0.000 1.000 395. 0.00 0.00 22.33 0.00 -41.40 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-5 thru 12 (PSZ) (G.SSW1) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (KBTU/HR) (SHR) (EBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) PSZ 1.000 190105.4 331. 0.207 1200.000 0.753 -2800.000 0.282 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 55200. 1.00 6.907 0.39 0.5 0.47 0.55 BLOW-THRU SPEED 1.10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Warehouse 1st Floor (fG.z 55200. 2720. 0.239 1.000 11406. 0.00 0.00 861.81 0.00-2361.46 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 1758:05 BDL RUN 5 REPORT- SV-A System Design Parameters for Restrooms (UVT) (G) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (KBTU/NR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) UHT 1.000 2014.3 37. 0.000 0,000 0.000 0,000 0.000 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECB MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 1269, 0,00 0.000 0.58 0.5 0.31 0.35 BLOW-THRU CONSTANT 0.00 0.00 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KHTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Restrooma (fG,r5) 1269. 0. 0,237 1.000 0. 0,00 0.00 0.00 -68,30 -68.30 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 RDL RUN 5 REPORT- LV-D Details of Exterior Surfaces WEATHER FILE- Seattle WA TMY2 NUMBER OF EXTERIOR SURFACES 15 (U-VALUE INCLUDES OUTSIDE FILM; WINDOW INCLUDES FRAME AND CURB, IF DEFINED) SURFACE WINDOWS-- - -S--- - - - -WALL- - - - -W A L L+ W I N D O W S- U-VALUE AREA U-VALUE AREA U-VALUE AREA AZIMUTH (BTU/HR-SQFT-F) (SQFT) (BTU/HR-SQFT-F) (SQFT) (BTU/HR-SQFT-F) (SQFT) North Wall -Lower (G,SSW1,E2) in space: Warehouse lst Floor (fG.s1) North Wall (T.SSW6.E10) in space: Warehouse 1st Floor (fG.s1) North Wall in space: Warehouse 1st Floor (fG.sl) North Wall (G.ENE2.E6) in space: Offices (fG.s2) North Wall (G.N3.E7) in space: Break Room (fG.s3) North Wall (G.N4.E8) in space: Training Room (fG.s4) East Wall -Lower (G.SSW1.E1) in space: Warehouse 1st Floor (fG.s1) East Wall (T.SSW6.E9) in space: Warehouse 1st Floor (fG.sl) East Wall (G.ENE2.E5) in space: Offices (fG.s2) South Wall (T.SSW6.E12) in space: Warehouse 1st Floor (fG.s1) South Wall -Lower (G.SSW1.E4) in space: Warehouse 1st Floor (fG.sl) West Wall -Lower (G.SSW1.E3) in space: Warehouse 1st Floor (fG.sl) West Wall (T.SSW6.E11) in space: Warehouse 1st Floor (fG.s1) Roof (T.N8.E18) in space: Break Room (fG.s3) Roof (T.SSW6,E13) in space: Warehouse 1st Floor (fG.s1) Flr (G.SSW1.U1) in space: Warehouse 1st Floor (fG.sl) Flr (G.ENE2.U2) in space: Offices (fG.s2) Flr (G.N3.U3) in space: Break Room (fG.s3) Flr (G.N4.U4) in space: Training Room (fG.s4) Fir (G.C5.U5) in space: Restrooms (fG.s5) 0.554 105.07 0.202 292.43 0,295 397.50 NORTH 0.000 0.00 0.055 2422.40 0.055 2422.40 NORTH 0.000 0.00 0.055 857.60 0.055 857.60 NORTH 0.445 90.00 0.055 178.00 0.186 268.00 NORTH 0.499 360.13 0.055 4910.87 0.085 5271.00 NORTH 0.462 173.90 0.055 185.60 0.252 359.50 NORTH 0.000 0.00 0.202 8223,50 0.202 8223.50 EAST 0.000 0.00 0.055 28416.00 0.055 28416.00 EAST 0.445 180.00 0.055 476.50 0.162 656.50 EAST 0.000 0.00 0.055 7296.00 0.055 7296.00 SOUTH 0.000 0.00 0.202 2280.00 0.202 2280.00 SOUTH 0.000 0.00 0.202 8880.00 0.202 8880.00 WEST 0.000 0.00 0.055 28416.00 0.055 28416.00 WEST 0.000 0.00 0.028 7596.25 0.028 7596.25 ROOF 0.000 0.00 0.028 194867.77 0.028 194867,77 ROOF 0.000 0.00 0.011 190105.39 0.011 190105.39 UNDERGRND 0.000 0.00 0.058 1759.42 0.058 1759.42 UNDERGRND 0.000 0.00 0.018 7596.25 0.018 7596.25 UNDERGRND 0.000 0.00 0.040 988.62 0.040 988.62 UNDERGRND 0.000 0.00 0.010 2014,32 0.010 2014.32 UNDERGRND Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- LV-D Details of Exterior Surfaces WEATHER FILE- Seattle WA TMY2 (CONTINUED) AVERAGE AVERAGE AVERAGE U-VALUE WINDOW WALL WINDOW+WALL U-VALUE/WINDOWS U-VALUE/WALLS WALLS+WINDOWS AREA AREA AREA (BTU/HR-SQFT-F) (BTU/HR-SQFT-F) (BTU/HR-SQFT-F) (SQFT) (SQFT) (SQFT) NORTH 0.491 0.060 0.092 729.10 8846.90 9576.00 EAST 0.445 0.087 0.089 180.00 37116.00 37296.00 SOUTH 0.000 0.090 0.090 0.00 9576.00 9576.00 WEST 0.000 0.090 0.090 0.00 37296.00 37296.00 ROOF 0.000 0.028 0.028 0.00 202464.02 202464.02 ALL WALLS 0.482 0.086 0.090 909,10 92834.91 93744.00 WALLS+ROOFS 0.482 0.046 0.047 909.10 295298.94 296208,00 UNDERGRND 0.000 0.012 0.012 0.00 202464.00 202464.00 BUILDING 0.482 0.032 0.033 909.10 497762.91 498671.97 Page 2 Dennody- Oxbow '� � U .K-. Inc.0 P116S4APEGAPERMIT TOPRACTICE 8]0NRiverside Dr. SuiteZO0 Renton, VVA98O57 Phone: 435'97D'37S3/FAX: 4ZS'97O'3756 Appendix B Contents: w Reference Building Simulation Reports o Monthly energy consumption byend use o 8EP3 o BEPU o ES-D o SV-A o LV'D _41aLrn_o1 Project/Run: Dermody DWA2 - Tukwila, WA - Baseline Design (x000) 150 Electric Consumption (kWh) 100 50 0 Jan Feb Mar Apr MayJun Jul Aug Sep Oct Nov Dec ® Area Lighting • Task Lighting ® Misc. Equipment Electric Consumption (kWh x000) Tan Space Cool Heat Reject. Refrigeration Space Heat HP Supp. Hot Water Vent. Fans Pumps & Aux. Ext, Usage Misc. Equip. Task tights Area Lights 0,0 El Exterior Usage Pumps & Aux. Ventilation Fans Run Date/Time: 09/25/19 l 17:58 Gas Consumption (Btu) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Water Heating • Ht Pump Supp. Space Heating 0.1 0.2 2.4 4.5 10.6 ❑ Refrigeration • Heat Rejection • Space Cooling 11.8 6.2 0.3 0,3 0.3 0,3 0.3 0.3 0,3 0,3 0,3 3.5 3.0 3.3 3.2 3,3 3.2 3.3 3.3 3.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.1 71.1 64.2 71.1 68.8 71.1 68.8 71.1 71.1 68.8 71.1 68.8 71.1 836.7 56.8 55.0 119.0 31.7 14 t F _ ;: 43.3 133.4 0.4 0.0 • 36.1 56.8 51.3 56.8 55.0 56.8 55.0 Gas Consumption (Btu x000,000) bn Space Cool Heat Reject. Refrigeration Space Heat 45.65 10,21 HP Supp. Hot Water 2.19 1-97 Vent. Fans Pumps & Aux. - - Ext. Usage Misc Equip. Task Lights Area Lights - - 'Total 47.84 12.18 11..84 2.17 I.30 0,00 2.02 1.94 1.80 1.78 1.74 1.71 0,3 3.3 0.1 0.3 3.2 0.2 0.3 3.4 3.5 39.0 1.4 55.0 56.8 669.1 2; .4 13f 8 1,i85.5j 0.26 5.72 31.67 104.49 1.84 1.94 2.13 23.22 eQUEST 3.65.7175 Monthly Energy Consumption by Enduse New Section 2 Page 1 Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- BEPS Building Energy Performance WEATHER FILE- Seattle WA TMY2 TASK MISC SPACE SPACE HEAT PUMPS VENT REFRIG HT PUMP DOMEST EXT LIGHTS LIGHTS EQUIP HEATING COOLING REJECT 6 AUX FANS DISPLAY SUPPLEM HOT WTR USAGE TOTAL EMI ELECTRICITY MBTU 1207.0 0.0 2856.0 0.0 65.8 0.0 4.9 137.8 0.0 0.0 12.1 0.0 4283.5 FM1 NATURAL-GAS MBTU 0.0 0.0 0.0 393.5 0.0 0.0 0.0 0.0 0.0 0.0 23.7 0.0 417.2 MBTU 1207.0 0.0 2856.0 393.5 65.8 0.0 4.9 137.8 0.0 0.0 35.8 0.0 4700.7 TOTAL SITE ENERGY 4700.74 MBTU TOTAL SOURCE ENERGY 13267.80 MBTU 23.2 KBTU/SQFT-YR GROSS -AREA 23.2 KBTU/SQFT-YR NET -AREA 65.5 KBTU/SQFT-YR GROSS -AREA 65.5 KBTU/SQFT-YR NET -AREA PERCENT OF HOURS ANY SYSTEM ZONE OUTSIDE OF THROTTLING RANGE = 0.93 PERCENT OF HOURS ANY PLANT LOAD NOT SATISFIED = 0.00 HOURS ANY ZONE ABOVE COOLING THROTTLING RANGE = 44 HOURS ANY ZONE BELOW HEATING THROTTLING RANGE = 0 NOTE: ENERGY IS APPORTIONED HOURLY TO ALL END -USE CATEGORIES. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- BEPU Building Utility Performance WEATHER FILE- Seattle WA TMY2 TASK MISC SPACE SPACE REAT PUMPS VENT REFRIG HT PUMP DOMEST EXT LIGHTS LIGHTS EQUIP HEATING COOLING REJECT 6 AUX FANS DISPLAY SUPPLEM HOT WTR USAGE TOTAL EM1 ELECTRICITY KWH 353760. 0, 836671, 0. 19289, 0. 1439. 40378. 0. 0. 3536. 0. 1255071. FM1 NATURAL-GAS THERM 0. 0. 0. 3935. 0. 0. 0. 0. 0. 0. 237. 0. 4172. TOTAL ELECTRICITY 1255071. KWH TOTAL NATURAL-GAS 4172. THERM 6.199 KWH /SQFT-YR GROSS -AREA 6.199 KWH /SQFT-YR NET -AREA 0.021 THERM /SQFT-YR GROSS -AREA 0.021 THERM /SQFT-YR NET -AREA PERCENT OF HOURS ANY SYSTEM ZONE OUTSIDE OF THROTTLING RANGE = 0.93 PERCENT OF HOURS ANY PLANT LOAD NOT SATISFIED = 0.00 HOURS ANY ZONE ABOVE COOLING THROTTLING RANGE = 44 HOURS ANY ZONE BELOW HEATING THROTTLING RANGE = 0 NOTE: ENERGY IS APPORTIONED HOURLY TO ALL END -USE CATEGORIES. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- ES-D Energy Cost Summary WEATHER FILE- Seattle WA TMY2 METERED TOTAL VIRTUAL ENERGY CHARGE RATE RATE USED UTILITY -RATE RESOURCE METERS UNITS/YR ($) ($/UNIT) ALL YEAR? PSE Elec 26 Com/Ind Lrg Demand ELECTRICITY EM1 1255071. KWH 96368. 0.0768 YES PSE Gas 41 Lrg NRes (>500 therm) NATURAL-GAS EM1 4172. THERM 4829. L.1575 YES 101197. ENERGY COST/GROSS BLDG AREA: 0.50 ENERGY COST/NET BLDG AREA: 0.50 Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-1 (PSZ) (G.ENE2) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (KBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) PSZ 1.000 1759.4 25. 0.055 55.000 0.764 -60.000 0.266 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 2300. 1.00 0.255 0.34 0.5 0.53 0.55 BLOW-THRU SPEED 1.10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Offices (fG.z2) 2300. 0. 0.000 1.000 126. 0.00 0.00 41.03 0.00 -54.61 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-263 (PSZ) (G,N3) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (EBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) PSZ 1.000 7596.2 69. 0.025 300.000 0.753 -400,000 0.282 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 18400. 1.00 2.037 0.34 0.5 0,53 0.55 BLOW-THRU SPEED 1,10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/BR) (KBTU/HR) (KBTU/HR) MULT Break Room (fG.z3) 18400. 0. 0.000 1.000 456. 0,00 0.00 207,09 0.00-383.65 Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-4 (PSZ) (G.N4) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQFT ) PEOPLE RATIO (KBTU/HR) (SHR) (KBTU/HR) (BTU/ETU) (BTU/BTU) (EBTU/HR) PSZ 1.000 988.6 40. 0.287 36.000 0.750 -60.000 0,268 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 1380. 1.00 0.153 0.34 0.5 0.53 0.55 BLOW-THRU SPEED 1.10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (RBTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Training Room (fG.z4) 1380. 0. 0.000 1.000 395. 0.00 0.00 22.33 0.00 -41.40 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for AC-5 thru 12 (PSZ) (G.SSW1) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING HEATING COOLING HEATING'' HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (SQET ) PEOPLE RATIO (RBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (RBTU/HR) PSZ 1.000 190105.4 331. 0.207 1200.000 0.753 -2800.000 0.282 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 55200. 1.00 6.907 0.39 0,5 0.47 0.55 BLOW-THRU SPEED 1,10 0.30 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/HR) (KBTU/HR) (KBTU/HR) MULT Warehouse 1st Floor (fG.z 55200. 2720. 0.239 1.000 11406. 0,00 0.00 861.81 0.00-2361.46 1. Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- SV-A System Design Parameters for Restrooms (UVT) (G) WEATHER FILE- Seattle WA TMY2 FLOOR OUTSIDE COOLING BEATING COOLING HEATING HEAT PUMP SYSTEM ALTITUDE AREA MAX AIR CAPACITY SENSIBLE CAPACITY EIR EIR SUPP-HEAT TYPE FACTOR (S4FT ) PEOPLE RATIO (KBTU/HR) (SHR) (KBTU/HR) (BTU/BTU) (BTU/BTU) (KBTU/HR) UHT 1.000 2014.3 37. 0.000 0.000 0.000 0.000 0.000 0.000 0.000 DIVERSITY POWER FAN STATIC TOTAL MECH MAX FAN MIN FAN FAN CAPACITY FACTOR DEMAND DELTA-T PRESSURE EFF EFF FAN FAN RATIO RATIO TYPE (CFM ) (FRAC) (KW) (F) (IN -WATER) (FRAC) (FRAC) PLACEMENT CONTROL (FRAC) (FRAC) SUPPLY 1269. 0.00 0.000 0.58 0.5 0.31 0.35 SLOW-THRU CONSTANT 0.00 0.00 SUPPLY EXHAUST MINIMUM OUTSIDE COOLING EXTRACTION HEATING ADDITION ZONE FLOW FLOW FAN FLOW AIR FLOW CAPACITY SENSIBLE RATE CAPACITY RATE ZONE NAME (CFM ) (CFM ) (KW) (FRAC) (CFM ) (KBTU/HR) (FRAC) (KBTU/BR) (FBTU/RR) (KBTU/HR) MULT Restrooma (fG.z5) 1269. 0. 0.237 1.000 0. 0,00 0.00 0.00 -68.30 -68.30 1. Page 1 • Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 17:58:05 BDL RUN 5 REPORT- LV-D Details of Exterior Surfaces WEATHER FILE- Seattle WA TMY2 NUMBER OF EXTERIOR SURFACES 15 (U-VALUE INCLUDES OUTSIDE FILM; WINDOW INCLUDES FRAME AND CURB, IF DEFINED) SURFACE. - - -WINDOWS- - - - - - -WALL- - - - -WALL+WINDOW S- U-VALUE AREA U-VALUE AREA U-VALUE AREA AZIMUTH (BTU/HR-SQFT-F) (SQFT) (BTU/HR-SQFT-F) (SQFT) (BTU/HR-SQFT-F) (SQFT) North Wall -Lower (G.SSW1.E2) in space: Warehouse 1st Floor (fG.sl) North Wall (T.55W6.E10) in space: Warehouse 1st Floor (fG.s1) North Wall in space: Warehouse 1st Floor (fG.s1) North Wall (G.ENE2.E6) in apace: Offices (fG.s2) North Wall (G.N3.E7) in space: Break Room (fG.s3) North Wall (G.N4.E8) in space: Training Room (fG,s4) East Wall -Lower (G.SSW1.E1) in space: Warehouse 1st Floor (fG.s1) East Wall (T,SSW6.E9) in apace: Warehouse 1st Floor (fG.81) East Wall (G.ENE2.E5) in space: Offices (fG,s2) South Wall (T.SSW6.E12) in space: Warehouse 1st Floor (fG.sl) South Wall -Lower (G.SSW1.E4) in space: Warehouse 1st Floor (fG.s1) West Wall -Lower (G.SSW1.E3) in space: Warehouse 1st Floor (fG.sl) West Wall (T.SSW6.E11) in space: Warehouse 1st Floor (fG.s1) Roof (T.N8.E18) in space: Break Room (fG.s3) Roof (T.SSW6.E13) in space: Warehouse 1st Floor (fG.s1) Flr (C.SSW1.U1) in space: Warehouse 1st Floor (fG.s1) Fir (G.ENE2.U2) in apace: Offices (fG.s2) Flr (G.N3.U3) in apace: Break Room (fG.s3) Flr (G.N4.U4) in space: Training Room (fG.s4) Flr (G.C5.U5) in space: Restrooms (fG.85) 0.554 105.07 0.202 292.43 0.295 397.50 NORTH 0.000 0.00 0.055 2422.40 0.055 2422.40 NORTH 0.000 0.00 0.055 857.60 0.055 857.60 NORTH 0.445 90.00 0.055 178.00 0.186 268.00 NORTH 0.499 360.13 0.055 4910,87 0.085 5271,00 NORTH 0.462 173.90 0.055 185,60 0,252 359.50 NORTH 0.000 0,00 0.202 8223,50 0.202 8223.50 EAST 0.000 0,00 0.055 28416.00 0.055 28416.00 EAST 0.445 180.00 0.055 476.50 0.162 656.50 EAST 0.000 0,00 0.055 7296,00 0.055 7296.00 SOUTH 0.000 0.00 0.202 2280.00 0.202 2280.00 SOUTH 0.000 0.00 0.202 8880.00 0.202 8880.00 WEST 0.000 0.00 0.055 28416.00 0.055 28416.00 WEST 0.000 0,00 0.028 7596.25 0.028 7596.25 ROOF 0.000 0.00 0.028 194867.77 0.028 194867.77 ROOF 0.000 0.00 0.011 190105.39 0.011 190105.39 UNDERGRND 0.000 0,00 0.058 1759.42 0.058 1759.42 UNDERGRND 0.000 0,00 0.018 7596.25 0.018 7596.25 UNDERGRND 0.000 0.00 0.040 988.62 0.040 988.62 UNDERGRND 0.000 0.00 0.010 2014.32 0.010 2014.32 UNDERGRND Page 1 Dermody DWA2 - Tukwila, WA DOE-2.2-50a 9/25/2019 175805 BDL RUN 5 REPORT- LV-D Details of Exterior Surfaces WEATHER FILE- Seattle WA TMY2 (CONTINUED) AVERAGE AVERAGE AVERAGE U-VALUE WINDOW WALL WINDOW+WALL U-VALUE/WINDOWS U-VALUE/WALLS WALLS+WINDOWS AREA AREA AREA (BTU/HR-SOFT-F) (BTU/HR-SQFT-F) (BTU/HR-SQFT-F) (SQFT) (SQFT) (SOFT) NORTH 0.491 0.060 0.092 729.10 8846.90 9576.00 EAST 0.445 0.087 0.089 180.00 37116.00 37296.00 SOUTH 0.000 0.090 0.090 0.00 9576.00 9576.00 WEST 0.000 0.090 0.090 0.00 37296.00 37296.00 ROOF 0.000 0.028 0.028 0.00 202464.02 202464.02 ALL WALLS 0.482 0.086 0.090 909.10 92834.91 93744.00 WALLS+ROOFS 0.482 0,046 0.047 909.10 295298.94 296208.00 UNDERGRND 0.000 0.012 0.012 0.00 202464.00 202464.00 BUILDING 0.482 0.032 0.033 909.10 497762.91 498671.97 Page 2 f\ City of Tukwila Department of Community Development 3/5/2020 TODD SCHUTZ 1200 FIFTH AVE - SUITE 1300 SEATTLE, WA 98101 RE: Permit Application No. M19-0176 DERMODY OXBOW Dear TODD SCHUTZ, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 10/17/2019, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 4/17/2020. 1f you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M19-0176 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Bill Rambo From: To: Subject: Todd Schutz <TSchutz@melsonvwwconox Monday, March 30' 20209:51 AM Bill Rambo; Maxwell Baker Andrea Cummins; Lynn Miranda; Phil Wood; Lou Berchicci; Jeffrey Zygler; Rachelle Ripley, BisaVl8mgas; ShanaK4arhsrum RE Dermody - Oxbow - Request for Extension: Permit #M 19-0176 Mechanical Permit I would like to formally request an extension to Permit # M19-0176 which is the Mechanical Permit for the Dermody — Oxbow project.VVearexvorkingthnoughthed ' nreviem/andshone|inaconnnmentsvvhichmnaVhaveanhnpactonthe building/electrical design. Therefnrevxecannotresubmni1forthee|ectrica|permitunti|theseconmnmentshavebeen addressed. We received the design review/shoreline comments on 2/26. Please accept this email as our request for extension and let me know if you need anything else in order to approve this extension. Best Regards Todd Schutz Project Architect Office 206 408 850 Direct 2064088645 New Email: TSchutc@ne|sonvmw.conn WWKNELSONW0RLDWUDE.COM WWW.CRAFTARCHUTECTS.CO08 NELSON"' FORMERLY CRAFT ARCwITZCTw WE'VE MOVED 12OUFifth Avenue Guita13DO Seattle, VVA981O1 Request for Permit Application Extension # Current ExpirationDuce: Extension Request: 7� �m�v��r ����� days L Signature/Initials CAUTION: This email originated from outside the City ofTukwila network. Please DO NOT open attachments orclick links from an unknown or suspicious origin. CITY OF TUKWILA MAR 3 0 2020 PERMIT CENTER r PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0176 PROJECT NAME: Dermody Oxbow DATE: 02/18/2021 SITE ADDRESS: 10500 W Marginal P1 S Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 3 after Permit Issued DEPARTMENTS: "61_5 42-PYW Building Division Public Works (VIA Nik 151P-\ Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/23/21 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required [z] n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/20/21 n Fire Fees Apply E Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping E] PW 0 Staff Initials: 12/18/2013 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0176 PROJECT NAME: Dermody Oxbow SITE ADDRESS: 10500 W Marginal P1 S DATE: 12/21/2020 Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 2 after Permit Issued DEPARTMENTS: 1_5 tax p-()-4?-o Building Division Public Works Vvi Fire Prevention Structural Planning Division Permit Coordinator LI PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/22/20 Structural Review Required REVIEWER'S INITIALS: DATE: r APPROVALS OR CORRECTIONS: Approved Corrections Required n P (corrections entered in Reviews) DUE DATE: 02/16/21 Approved with Conditions Ei Fire Fees Apply E Denied (ie: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire El Ping 0 PW 0 Staff Initials: 12/18/2013 r PERIT COORD COPY' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0176 DATE: 05/01/2020 PROJECT NAME: DERMODY OXBOW SITE ADDRESS: 10500 W MARGINAL PL S Original Plan Submittal Response to Correction Letter # X Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: uilding Division r110 Public Works Fire Prevention Structural Planning Division Permit Coordinator IN PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 05/05/2020 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required L DUE DATE: 06/30/2020 Approved with Conditions ri Fire Fees Apply Denied (con-ections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials- 12/18/2013 , C e. 4z, *IP tty A 1 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0176 DATE: 10/17/2019 PROJECT NAME: DERMODY OXBOW SITE ADDRESS: 10500 W. MARGINAL PL. S. X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Pr\PAtO Building Division Public Works PM /ONO Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 10/22/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/19/2019 Approved Corrections Required LI E (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire El Ping 0 PW 0 Staff Initials: 12/18/2013 PROJECT NAME: asino PERMIT NO: \--"' t4 1 eit' t7 SITE ADDRESS: to 00 IA) frWerii44.4 p( S ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS S.— 1 — )'0?-0 Qqaxixfaxi 4t4) Sumlary of Revision: Wurat-44 1. /4(1fir(k le\ 444A 40 AO - ,ia.f 11e ‘0‘.0 uurtkio ii le iiV. od-e-r5 Received by: r4vib— i REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 7 Summary of Revision: /4.,-,04,d ti-v2.6 --f-u-is -to //17a/z c_cm,--./tece_s,e , Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (ple REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) , City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWkitov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2/16/2020 Plan Check/Permit Number: M19-0176 ri Response to Incomplete Letter # ri Response to Correction Letter # Revision # 40 after Permit is Issued El Revision requested by a City Building Inspector or Plans Examiner [1] Deferred Submittal # D Project Name: DERMODY OXBOW Project Address: 10500 W. MARGINAL PL S Contact Person: JAMES VAN DEUSEN Summary of Revision: C OF TI.JIMILP 1 8 Phone Number: 425-970-3753 CENTETI Mechanical: M-0.2: - Updated Air Terminal Schedule and Exhaust Fan Equipment Schedule. M-1.1: - Revised HVAC layout at Pick Up Room. M-2.1: - Revised HVAC layout at Pick Up Room and Sprinkler. - Added transfer fans (TF-1,2), wall fan (WF-1) and louvers. M-3.1: - Added mechanical details. Sheet Number(s): M-0.2, M-1.1, M-2.1, M-3.1 "Cloud" or highlight all areas of revision including date ofrevision Received at the City of Tukwila Permit Center by: 17k Entered in TRAKiT on 04/ OP" WAPermit Center \Templates\Forms‘Revision Submittal Form.doc Revised: August 2015 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http:i'/www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12/18/2020 Plan Check/Permit Number: On 11-- 01 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ® Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: DERMODY OXBOW Project Address: 10500 W. MARGINAL PL S Contact Person: JAMES VAN DEUSEN Summary of Revision: Mechanical: Added HVLS fans to main warehouse. RECEIVE CITY OF TUK1,1- DEC 2 1 2020 PERMIT CENT Phone Number: 425-970-3753 Electrical: 1. Revised Site Plan and Added Electric Vehicle conduit plan (conduit only). 2. Added receptacles and power for owner's equipment. 3. Revised power for HVLS fans. 4. Revised panel schedules. Sheet Number(s): ES-1.0.0, ES-1.0.1, E-2.1.0, E-2.1.1, E-2.1.2, E-2.3.1, E-5.0.0, E-5.0.1, M-0.2, M-1.1, M-3.1 "Cloud" or highlight all areas of revision including date ofrevision Received at the City of Tukwila Permit Center by: ti [i Entered in TRAKiT on AP-/ a'1 ladad W:\Pcrmit Center\TcmplatesWorms\Revision Submittal Form,doc Revised: August 2015 City Cf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Mi 0 I 70 Date: 04/24/2020 Plan Check/Permit Number: 50-- • Response to Incomplete Letter # • Response to Correction Letter # [s] Revision # 1 after Permit is Issued [1] Revision requested by a City Building Inspector or Plans Examiner E Deferred Submittal # D Project Name: DERMODY OXBOW Project Address: 10500 W. MARGINAL PL S Contact Person: JAMES VAN DEUSEN Phone Number: 425-970-3753 Summary of Revision: Modified exhaust ductwork for new electrical room layout. Revised Warehouse Diffuser detail 2/M-3.1 per architectural changes. RECEIVED CITY OF TUKWILA MY 01 MO Sheet Number(s): M-2.1, M-3.1 "Cloud" or highlight all areas of revision including datepfrevision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on cJ WAPermit CenteATemplates \FormiARevision Submittal Form.doc Revised: August 2015 STATE MECHANICAL COMPANY y Page 1 of 3 L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m. to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office (https://lni.wa.nov/agency/contact/#office-locations), or you can call the Office of Information and Assistance at 360-902-5800. Labor & Industries : Int STATE MECHANICAL COMPANY Owner or tradesperson Principals PLATZ, GERRICK D, PRESIDENT LYNCH, JOHN MICHAEL, VICE PRESIDENT DEWITT, RALPH E (End: 12/18/2012) Doing business as STATE MECHANICAL COMPANY WA UBI No. 600 611 697 8706 S 222nd St KENT, WA 98031 206-575-7627 KING County Business type Corporation Governing persons JOHN LYNCH GERRIK PLATZ; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties PLUMBING License no. STATEMC141C7 Effective — expiration 02/27/1986— 09/01/2021 Bond TRAVELERS CAS & SURETY CO $6,000.00 Bond account no. 200686359 Received by L&I Effective date 08/14/2001 07/27/2001 Expiration date Until Canceled o https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600611697&LIC=STATEMC141C7&SAW= 6/22/2020 Air Terminal Schedule Symbol Manufacturer Model Type Serves Notes CD TUTTLE & BAILEY SQD SUPPLY BREAK ROOM 1 CD TUTTLE & BAILEY SQD SUPPLY CONFERENCE ROOM 1 CD TUTTLE & BAILEY SQD SUPPLY HR WORKROOM 1 CD TUTTLE & BAILEY SQD SUPPLY OPEN WORKROOM 1 CD TUTTLE & BAILEY SQD SUPPLY OPTIONAL WORKROOM 1 CD TUTTLE & BAILEY SQD SUPPLY STATION MANAGER WORKROOM 1 CD TUTTLE & BAILEY SQD SUPPLY TRAINING ROOM 1 EGA TUTTLE & BAILEY CRE500 EXHAUST ELEC. ROOM 1 EGA TUTTLE & BAILEY CRE500 EXHAUST JANITOR ROOM 1 EGA RG RG TUTTLE & BAILEY TUTTLE & BAILEY TUTTLE & BAILEY CRE500 PR PR EXHAUST RETURN RETURN RESTROOM BREAK ROOM CONFERENCE ROOM 1 1 1 RG TUTTLE & BAILEY PR RETURN CONTEMPLATION ROOM 1 j RG TUTTLE & BAILEY PR RETURN HR WORKROOM 1 1 RG TUTTLE& BAILEY PR RETURN NEW MOTHERS 1 RG TUTTLE & BAILEY PR RETURN OPEN WORKROOM 1 RG TUTTLE & BAILEY PR RETURN OPTIONAL WORKROOM 1 RG TUTT -F & BAILEY PR RETURN STATION MANAGER WORKROOM 1 RG TUTTLE & BAILEY PR RETURN TRAINING ROOM 1 1. FRAME STYLE TO MATCH ARCHITECTURAL CEILING TYPE. -HVAC Equtprruent Schedule Symbol Manufacturer Model Serves ESP FfP Total Airflow Outside Air Totai Cooling Sensible Cooling Cooling Efficiency Heat Input Heat Output Voltage Phase FLA MOCP Weight Notes AC-1 TRANE YHC060F4 OFFICE AREA 0.50 in-wg 1 2000 CFM 235 CFM 55000 Btu/h 42000 Btu/h 15 SEER 60 MBH 49 MBH 460 V 3 13 A 20A 14521bf (1) (2) (4) (5) (6) AC 2 TRANE Y+0150G4 BREAK ROOM 0-50 in-wg 3 5000 CFM 1235 CFM 15000D Btu/h 113000 Btu/h 12.1 EER 250 MBH 200 MBH 460 V 3 30 A 40 A 3753 Ibf (1) (2) (4) (5) (7) AC-3 TRANE YHD150G4 BREAK ROOM 0.50 in-wg 3 5000 CFM 1235 CFM 150000 Btu/h 113000Btu/h 12.1 EER 250 MBH 200 MBH 460 V 3 30 A 40A 3753 Ibf (1) (2) (4) (5) (7) AC-4 TRANE YHC036E4 TRAINING ROOM 0.50 in-wg 314 1200 CFM 295 CFM 36000 Btu/h 27000 Btu/h 14.4 SEER 60 MBH 49 MBH 460 V 3 11 A 15A 1119IV (1) (2) (4) (5) (6) AC-5 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 121 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 Ibf (1) (2) (3) (4) (5) (7) AC-6 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 12.1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 Ibf (1) (2) (3) (4) (5) (7) AC-7 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 12.1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 lbf (1) (2) (3) (4) (5) (7) AC-8 TRANE YHD150G4 WAREHOUSE 0.50 in -wig 3 5000 CFM 1410 CFM 1500DO Btu/h 113000 Btu/h 12-1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 Ibf (1) (2) (3) (4) (5) (7) AC-9 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 12.1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 Ibf (1) (2) (3) (4) (5) (7) AC-10 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 12.1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 lbf (1) (2) (3) (4) (5) (7) AC-11 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 12.1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3753 Ibf (1) (2) (3) (4) (5) (7) AC-12 TRANE YHD150G4 WAREHOUSE 0.50 in-wg 3 5000 CFM 1410 CFM 150000 Btu/h 113000 Btu/h 12.1 EER 350 MBH 280 MBH 460 V 3 30 A 40 A 3758 Ibf (1) (2) (3) (4) (5) (7) 1. PROVIDE A PRE -FABRICATED INSULATED ROOF CURB, MINIMUM 14" HIGH. 2. PROVIDE CO2 SENSOR IN THE RETURN AIR DUCTWORK TO MAINTAIN MAXIMUM 1,000 PPM CO2 AND MAINTAIN POSITIVE BUILDING PRESSURE. 3. PROVIDE AN INTERNALLY LINED DROP PLENUM WITH 4-WAY DRUM LOUVER DISTRIBUTION, UNITED ENERTECH "DPD" OR EQUAL. 4. VERIFY DUCT SMOKE DETECTOR REQUIREMENTS WITH FIRE PROTECTION. IF REQUIRED, DETECTOR PROVIDED AND WIRED BY FIRE ALARM, INSTALLED BY M.C. 5. SINGLE ZONE VARIABLE AIR VOLUME UNIT CONFIGURATION OR EQUIVALENT. 6. MICROPROCESSOR CONTROLS, HINGED PANELS/2" MERV 8 FILTERS, STANDARD CONDENSER COIL W/HAIL GUARD, THROUGH THE BASE GAS & ELECTRICAL, POWERED CONVENIENCE OUTLET, FROSTAT & CRANKCASE HEATER, UNITED MOUNTED CIRCUIT BREAKER, 0-100% LOW LEAK INTEGRATED ECONOMIZER WITH FAULT DETECTION/DIAGNOSTICS, BACNET COMMUNICATIONS INTERFACE, FAN FAILURE SWITCH AND DISCHARGE AIR SENSING TUBE, STAINLESS STEEL HEAT EXCHANGER. 7. HINGED PANELS/2" MERV 8 FILTERS, STANDARD CONDENSER COIL W/HAIL GUARD, THROUGH THE BASE GAS & ELECTRICAL, POWERED CONVENIENCE OUTLET, UNIT MOUNTED CIRCUIT BREAKER, 0.100% LOW LEAK INTEGRATED ECONOMIZER WITH FAULT DETECTION/DIAGNOSTICS, BACNET COMMUNICATIONS INTERFACE, FAN FAILURE SWITCH AND DISCHARGE AIR SENSING TUBE, MODULATING GAS HEAT, 3 HP VFD SUPPLY FAN, STAINLESS STEEL DRAIN PAN, FIELD INSTALLED CO2 SENSOR (DCV) Exhaust Fan Equipment Schedule - S.I.C. Symbol Manufacturer Model Serves Weight HP Voltage Phase Notes EF-1 COOK ACED135D (VF) RESTROOM 72.00 Ibf 3/4 115 V 1 (1) (2) (3) (4) EF-2 COOK ACED135D (VF) RESTROOM 72.00 Ibf 314 115 V 1 (1) (2) (3) (4) EF-4 COOK GC-168 REMOTE RESTROOM 12.00 Ibf 52.5W 115 V 1 (2) EF-3 COOK GC-168 REMOTE RESTROOM 12.00 Ibf i52.5W 115 V 1 (2) 1. PREFABRICATED INSULATED ROOF CURB PROVIDED BY G.C. 2. FAN OPERATION TO BE INTERLOCKED WITH TIME CLOCK. SEE PLANS FOR TIME CLOCK LOCATION. 3. PROVIDE BIRD SCREEN. 4. PROVIDE FAN SPEED CONTROLLER MOUNTED IN ACCESSIBLE LOCATION NEAR EQUIPMENT. Electric Heater Schedule Symbol Manufacturer Model Serves Heat Output Voltage Phase Notes ECH-1 Marley Engineered Products CDF-558 WOMENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-2 Marley Engineered Products CDF-558 WOMENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-3 Marley Engineered Products CDF-558 MENS RESTROOM 5 KW 208 V 1 (1) (2) (3) j (4) ECH4 Marley Engineered Products CDF-558 MENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-5 Marley Engineered Products AWH4404F SPRINKLER ROOM 3 KW 208 V 1 (1) (2) (3) 1. COLOR SELECTED BY ARCHITECT. 2. INTEGRATED TAMPER PROOF THERMOSTAT. 3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4. PROVIDE WITH CDF-RE RECESS ENCLOSURE AND CDF-TK TRIM KIT. VENTILATION AIR TABLE HVAC UNIT AREA SERVED OCCUPANT LOAD REQUIRED VENTILATION REQUIRED OUTSIDE AIR (CFM) DESIGN OUTSIDE AIR (CFM) NOTES AC-1 HR WORK 1 (107 SF) 5 CFM/PERSON 0.06 11 ROOM (105) CFM/SF OPEN 8 (762 SF) 5 CFM/PERSON 0.06 86 WORKROOM CFM/SF (106) CONFERENCE 16 (413 SF) 5 CFM/PERSON 0.06 105 ROOM (107) CFM/SF OPTIONAL 1 (134 SF) 5 CFM/PERSON 0.06 13 WORKROOM CFM/SF (108) STATION 1 (192 SF) 5 CFM/PERSON 0.06 17 MANAGER CFM/SF ROOM (109) TOTAL. OUTSIDEAIR 232 235 AC-2,3 BREAK ROOM 306 (7,402 SF) 5 CFM/PERSON 0.12 2,418 (104) CFM/SF NEW MOTHERS 1 (50 SF) 5 CFM/PERSON 0.06 8 ROOM(110) CFM/SF CONTEMPLATION 1 (50 SF) 5 CFM/PERSON. 0.06 a ROOM (111) CFM/SF TOTAL OUTSIDE AR 2,434 2,470 ACA TRAINING ROOM W (1,007 SF) 10 CFWPERSON 0.12 291 (103) CFM/SF TOTAL OUTSIDE AIR 291 295 AC5-12 WAREHOUSE 330 (187,380 SF) 0.06 CFMISF 11,243 TOTAL OUTSIDE AIR 11,243 11,280 EF-1 WOMEN'S TOILET 18 WC 70 CFM EXHAUST PER 1,260 (113) WC/U TOTALOUTSIDEAIR 1,260 1,800 QUANTITIES ARE EXHAUSTED EF-2 MEN.'S TOILET 10 WC, a U 7D CFM EXHAUST PER 1,260 (115) WC/U JANITOR CLOSET NOT OCCUPIED N/A 10D (120) (125 SF) ELEC. ROOM NOT OCCUPIED N/A 100 (123) (282 SF) TOTAL OUTSIDE AIR 1,460 2,000 QUANTITIES ARE EXHAUSTED EF-3, 4 MEN'S REMOTE 1 wC, 1 U 70 CFM EXHAUST 140 TOILET PER WCN WOMEN'S 2 WC 70 CFM EXHAUST 140 REMOTE TOILET PER WC/U TOTAL OUTSIDE AIR 280 300 QUANTITIES ARE EXHAUSTED *REQUIRED OUTSIDE AIR PER IMC 2015 CHAPTER 4. FILE COPY plan r21 U, i¢'J'raat 3 :G &t W3 c R+ btiL1r1S 'lnp7i)Vdl OP f 1 � � p �[ ltAt! ttS !".�fi ( c author r e v ow n cf .env .off nq cwe @, �rOmdnc kE 2ipi a 3 n .Vef! "7 z,J COD, Ar,1 Gay oY ""._.1 BUILDING OIV48iON SWIM i,nail t> ' mime U.: the scow 4 of Wax "T"ou... aptlro'0 of Het 1'uka4 euktwF.: 7 'v' 'In 'COTE: keveawns anll muse ; Awls or gg 'AYY and mar a1oll,gle a11d91onat Olin �eiR ice.........__ SEPARATE PERMIT REQUIRED FOR: REVIEWED FOR CODE COMPLIANCE APPROVED p ED Mechanicol p Electrical 4(i DEC 22 2020 I,I' Plumbing (�,KiGas Piping City of Tukwila BUILDING DIVISION City of Tukwila BUILDING DIVISION RECEIVED ^ CITY OF TUKWILA. REVISION NQ.d� DEC 2 12020 PERMIT CENTER yy TEI #. 19-413 PM: JV CHECKED BY: PKR/ANT ISSUED: 04/17/20 rnm-o % 11 NOTE: 1-1/2" COND. DOWN TO 4" N CLASS 1 MOTORIZED OSA DAMPER WITH 3 CFM/SF @1" WG LEAKAGE HUB DRAIN, SEE FOR WORK IN THIS AREA O a RATE AND CLASS 1 MOTORIZED RETURN AIR DAMPER WITH 4 CFM/SF PLUMBING PLANS FOR SEE REMOTE TOILET E AC o o S 1" WG LEAKAGE RATE INTEGRAL TO ALL AC UNITS. PLAN ON SHEET TOILET @ CONTINUATION. (Q 51 FOR WORK IN THIS AREA SEE BREAK ROOM HVAC Y PLAN ON SHEET M-21. i I 1Y,1Q0 p7 — J — w _ _ 1.3 AC I 3/4" c �x 1 SEE DETAILS 1 10 -- - _ 77 - - _ _ 1 1/2" C — — — — — — — —I — — — — — — — 1.6 =k A oo z I—� P Ac �— r—� �r—� 1"C 7C r—r 1"c Aa eSEE DETAILS 1 10 r' c I� ——�—t�— — —j— LEEDETAILS1 2ABC 6ALL CO2 q7 1 s u m a a. ry F RN }� SEA DETAILS 1 10 — — — — _ tlucTTu Et - - - w�� ��, V--r— ill C •� ,-0r nY':?a .r...�N..'� sv ...„v..s^R1lAr --�— — I I I I I I I I I I 1 I I I p, D j EF SEE DETAIL 15 - T - - - ... io9oL Gi00®... - - - - AC - 3L - - - - - - - - 0 eel AC SEE DETAILS 1 10 3/4" C E� a AC CO 1�� C VL (TOP.) ill C AC CO AC CO -- r —, 10 11 12 O L I IQeoa® — — — — — — r r — — — — — —I r - —I — _ 1 m I _I_ I_ — x > �' 1" C L -\ J L-\J L- J L- J _ O > 2 ' EF SEED TAIL \ \ \ I (TO1 P.) — — — — — — — — — — — — — — — — — — — — — — 0 F .,_ FOR WORK IN THIS AREA SEE TRAINING I I 4.7 LU LLJ ROOM HVAC PLAN ON _ xe SHEET M-2.1. INSTALL HVLS FANS PER MANUFACTURER'S RECOMMENDATIONS AND r 1-1 /4" COND. DOWN MOUNT SUSPENDED FROM THE ROOF TRUSSES. COORDINATE EXACT TO MOP SINK. DAYLIGHT @ 6" LOCATION AND HEIGHT IN FIELD SUCH THAT THE CENTER OF THE FAN IS ABOVE RIM. CENTERED BETWEEN SPRINKLER HEADS. SPRINKLER SPACING GOVERNS. c COORDINATE WITH OTHER TRADES AND MAINTAIN SEPARATION DISTANCE BETWEEN FANS OF A MINIMUM OF 30 FT. (TYP.) B' OVERALL MECHANICAL PLAN �.SCALE: 1/32" = 1'-0" 6@ RE EVI WED FOR CODE COMPLIANCE APPROVED y DEC 22 2020 City Of Tukwila BUILDING DIVISION m N RECEIVED -� '.!TV OF TUKWI!_.L TE1 #: 19-413 DEC 2. i 2020 v PM: JV CHECKED BY: PKR/ANT PERMIT CENTEF ISSUED: 04/17/20 v io 0 N C-1 OVERALL MECHANICAL PLAN 1 M —1.1; MECHANICAL ii MECHANICAL SHEET LIST SHEET Sheet Name M-0.1 MECHAN ICAL NOTES AND LEGENDS M-0.2 MECHANICAL SCHEDULES OVERALL M C C M-1.1 OVERALL MECHANICAL PLAN ENLARGED VAC PLANS L S M-2.1 ENLARGE HVAC PLANs V-3.1 MECHANICAL DETAILS IVI-4-1 HEATING ING -&COOLING LOADS M-4.2 MECHANICAL ENERGY CODE 4-43 ENVELOPE -ENERGY CODE_ HVAC DESIGN CONDITIONS JOB LOCATION: TUKWILA, WA 47.51 N LAT., 122.30 W LONG. ELEVATION: 30 FT CLIMATE ZONE: 4C DESIGN CONDITIONS: 28*F WINTER DRY BULB -ASHRAE 90.1 - 2013 HEATING DESIGN TEMPERATURE 99.6% 82.10F DRY BULB AND 63.90F MEAN COINCIDENT WET BULB SUMMER DESIGN - ASRRAE 90.1 - 2013 COOLING DESIGN TEMPERATURE 1.0% 607 WINTER INDOOR DESIGN DRY BULB - HEATING WAREHOUSE 85*F DRY BULB AND 50% RH INDOOR DESIGN - COOLING WARE -HOUSE 70*F WINTER INDOOR DESIGN DRY BULB - HEATING OFFICE AREA 75°F DRY BULB AND 50% RH INDOOR DESIGN - COOLING OFFICE AREA CALCULATIONS BASED ON ASHRAE DESIGN CRITERIA AND CALCULATION METHODOLOGY. HVAC LEGEND �/48 AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCTCONNECTION TV TURNINGVANE SUPPLY DUCT UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION C_ CONDENSATE DRAIN 15 AIR CONDITIONER #1 OT THERMOSTAT THERMOSTAT (W/LOCKING COVER) SENSOR HUMIDISTAT (9�2 CARBON DIOXIDE SENSOR CONT. CONTINUATION 7YP. TYPICAL CFM CUBIC FEET PER MINUTE DI3 DRY BULB TEMPERATURE DG DOOR GRILLE we WET BULB TEMPERATURE MBH 1,000 BRITISH THERMAL UNITS/F+R. ESP EXTERNAL STATIC PRESSURE EG EXHAUST GRILLE RG RETURN GRILLE CD CEILING DIFFUSER RA RETURN AIR SA SUPPLY AIR CDF CEILING -DIFFUSER WITH FIRE DAMPER RGF RETURN GRILLE WITH -FIRE -DAMPER CDFP CEILING DIFFUSER FOOD PREPARATION RGFP RETURN GRILLE FOOD PREPARATION Co CLEAN OUT VD VOLUME DAMPER MBS METAL BUILDING SUPPLIER M.0 MECHANICAL CONTRACTOR G.G GENERAL CONTRACTOR O/A OUTSIDE AIR SEQUENCE OF OpFPAT_1nKIQ THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL CONTROLS, CONTROL WIRING, AND CONTROL DESIGN. ADHERE TO 2015 WSEC SECTION C403.2A EXHAUST FANS: 1. EF-1-4 TO BE CONTROLLED BY TIME CLOCK. FAN TO RUN DURING OCCUPIED HOURS. BACKDRAFT DAMPER SHALL OPEN WHEN FAN IS OPERATING. OFFIC E WAREHOUSE AREA AC-1-191- PACKAGED ROOFTOP UNIT WITH 7-DAY PROGRAMMABLE THERMOSTAT. PROVIDE OFFICE AC AND TRANING ROOM AC WITH ZONE CONTROL WAREHOUSE TO BE CONTROLLED THROUGH BMS. PROVIDE TEMPERATURE SENSOR IN SPACE. THERMOSTATIC SETBACK CONTROLS SHALL BE CONFIGURED TO SET BACK OR TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55-F OR UP TO 85-F. BMS TO ADJUST EQUIPMENT START TIME REQUIRED TO BRING EACH AREA SERVED UP TO DESIGN TEMPERATURE JUST PRIOR TO SCHEDULED OPPUPANCY (C403.2 4.3). PROVIDE AUTOMATIC CONTROLS TO CLOSE OSA DAMPER DURING UNOCCUPIED EQUIPMENT OPERATION; NOT INCLUDING ECONOMIZER COOLING, NIGHT FLUSH, OR IMC REQUIRED OSA I EXHAUST. ECONOMIZERS NOT TO INCREASE BUILDING HEATING ENERGY USE DURING NORMAL OPERATION (C403.31). ECONOMIZER HIGH -LIMIT SHUTOFF CONTROLS PER TABLE C403.3.3.3. PROVIDE COOLING STAGE REQUIREMENTS PER TABLE C403.3.1. OCCUPIED, SINGLE ZONE VAV ZONE TEMPERATURE 18 GREATER THAN ITS COOLING SETPOINT OR WHEN THE ZONE TEMPERATURE IS LOWER THEN ITS HEATING SETPOINT UNOCCUPLIED: SINGLE ZONE VAV ZONE TEMPERATURE IS GREATER THAN ITS UNOCCUPIED COOLING SETPOINT OR WHEN THE ZONE TEMPERATURE IS LOWER THEN ITS UNOCCUPIED HEATING SET POINT. COOLING SEASON 1. OUTDOOR AIR DAMPER OPEN TO ITS MAXIMUM CFM REQUIREMENT. 2. THE INDOOR FANS TURN ON. 3. COMPRESSOR(S) AND EXPANSION VALVE OPERATE TO MAINTAIN AN INDOOR TEMPERATURE OF 75-F IN OFFICE AREAS AND 80-F IN WAREHOUSE. 4. WHEN THE OUTDOOR TEMPERATURE DROPS BELOW 60°F THE SYSTEM SHALL GO INTO ECONOMIZER CYCLE. THIS CYCLE CAUSES THE COMPRESSORS TO SHUT DOWN. WHEN THE OUTDOOR TEMPERATURE (TO BE ADJUSTABLE) IS BETWEEN 60-F AND 55-F, THE SYSTEM SUPPLIES 100% OUTDOOR AIR (TO 13E ADJUSTABLE) AND EXHAUSTS ADEQUATE RETURN AIR TO MAINTAIN POSITIVE BUILDING PRESSURE. WHEN THE OUTDOOR TEMPERATUE IS BELOW 55°F, THE OUTDOOR AIR DAMPER REMAINS AT THE CFM REQUIRED. HEATING SEASON: 1. OUTDOOR AIR DAMPER OPEN TO ITS MAXIMUM CFM REQUIREMENT. 2. THE INDOOR FAN TURNS ON. 3. THE GAS FURNACE SHALL RUN TO MAINTAIN AN INDOOR TEMPERATURE OF 70°F. DEMAND CONTROL VENTILATION - A. UNIT IS TO RUN CONTINUOUSLY WHILE BUILDING IS OCCUPL[ED. B. A REMOTE PANEL IN STATION MANAGER WORKROOM FOR UNIT ALARMS. C. FOR THOSE ZONES EQUIPPED WITH AN OCCUPANCY SENSOR OR CO2 SENSOR, OUTDOOR AIRfLOW SHALL BE RESET 1BASED ON OCCUPANCY STATUS AND/OR MEASURED CO2 CONCENTRATION. BUILDING CONTROLS AND MONITORING SYSTEMS: OPTION 1: CONTROLS AND MONITORY SYSTEM BY LIGHTSTAT. PROVIDE CENTERALIZED CONTROL PLATFORM AND INTERFACE GAS METERING BY PULSE OUTPUT. WATER METERING BY PULSE OUTPUT. LIGHTSTAT CONTACT: TOM ALDRICH 8607384111 OPTION 2: CONTROLS AND MONITORY SYSTEM BY EMWE. PROVIDE CENTRALIZED CONTROL PLATFORM AND INTERFACE. EMME CONTACT: JON BRODEUR 503-793-3792 1 GENERAL NOTES: HVAC DESIGN NOTES 14. MANUAL OVER -RIDE CONTROL (EMERGENCY SHUT -DOWN) SWITCHES FOR ALL HVAC UNITS SHALL BE AIR DISTRIBUTION LOCATED IN LOCKING COVER ADJACENT TO FIRE ALARM ANNUNCIATOR PANEL OR OTHER LOCATIO 1 ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION AND PER NFPA 92k N REQUIREMENTS OF THE LOCAL BUILDING CODES PIPING, 1. SUPPLY, RETURN, AND O.A. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL IN ACCORDANCE WITH SMACNA 1 REFRIGERANT PIPING SHALL BE TYPE L OR REFRIGEfZAI:')N SERVICE OPPERTU DUCT CONSTRUCTION STANDARDS, LATEST EDITION. ALL JOINTS AND SEAMS IN ALL SHEETMETAL DUCTWORK SHALL BE SEALED USING BRAZED JOINTS. 2015 INTERNATIONAL BUILDING CODE WITH AMENDMENTS 15. PROVIDE ACCESS PANELS IN NON -ACCESSIBLE CEILINGS AND IN WALL STRUCTURE TO ALLOW WITH DUCT SEALER. C B BRAZ I 2015 UNIFORM PLUMBING CODE WITH AMENDMENTS ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEMS. ACCESS It 2015 INTERNATIONAL MECHANICAL CODE WITH AMENDMENTS PANELS IN CEILING AND WALLS SHALL BE PROVIDED WHERE SHOWN ON THE ARCHITECTURAL 2. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT' 5HALL BE TRAPPED AND ROUTED TO THE NEAREST FLOOR DRAIN 2017 NATIONAL ELECTRICAL CODE WITH AMENDMENTS 2015 INTERNATIONAL FUEL GAS CODE WITH AMENDMENTS DRAWINGS OR NECESSARY TO ACCESS DAMPERS, VALVES, ETC. COORDINATE 2. EXTERIOR SUPPLY AND RETURN DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL WITH ALL SEAMS CAULKED AND OR SERVICE SINK UNLESS OTHERWISE SHOWN N EXACT LOCATION OF . CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC (EXCEPT INSULATED 2015 INTERNATIONAL ENERGY CONSERVATION CODE WITH AMENDMENTS ALL Aq��ESS PANELS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS. SEALED WEATHERTfGHT. COPPER IN HVAC PLENUMS). CONDENSATE SHALL BE PUMPED AS REQUIRED. PVC CONDENSATE PIPING EXPOSED TO WEATHER SHALL BE UV PROTECTED PER MANUFACTURrf;`S RECOMMENDATIONS. 16. ALL MECHANICAL EQUIPMENT SHALL BE LABLED WITH A SEMI -RIGID PLASTIC LAMINATE WITH Z' HIGH 3. ALL OPEN ENDED DUCTS AND FAN OUTLETS SHALL HAVE 1/2" X 1/2"HARDWARE CLOTH AFFIXED OPENING. 3. PROVIDE MANUAL AIR VENT (WITH DRAIN) AT HIGH PAINTS OF ALL RECIRCULATING WATER PIPINGSYSTEMS. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ENGINEER OR WHITE LETTERS ON A BLACK BACKGROUND SECURELY AFFIXED TO THE EQUIPMENT THE NAMEPLATE 4. EXHAUST DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING 4. PIPING AT PUMPS AND EQUIPMENT SHALL BE SUPPORTED 80 THAT NO PIPING OR ACCESSORY LOAD is r:ARRIED BY TH ARCHITECT PRIOR TO ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL SHALL SHOW THE EQUIPMENT TAG USED ON THESE DRAWINGS. AFFIX LABELS ON EQUIPMENTSOTHAT STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL BE PER SMACNA STANDARDS. EQUIPMENT. SHOP DRAVIANGS SHALL INCLUDE: ALL EQUIPMENT SCHEDULED OR IT IS VISIBLE AT THE ROOF LEVEL AND PLACE ANOTHER LABEL THAT IS VISIBLE FROM THE FLOOR LEVEL SPECIFIED ON THE DRAWINGS: DUCTWORK DRAWN TO 1/4" SCALE OR THE SCALE BELOW. PUMP OR EQUIPMENT. SHOWN ON THE DRAWINGS; REFRIGERANT PIPING AND CONTROL WIRING SCHEMATICS E CERTIFIED BY THE AIR CONDITIONING EQUIPMENT MANUFACTURER. FAILURE TO SUBMIT 5. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M-KE (U.L. 181 LISTED, CLASS I FLEXIBLE AIR DUCT) OR EQUAL. PROVIDE THERMAFLEX 5. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR 17. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES AND HEIGHTS. M-KE R-6 (R-VALUE - 4.6 MINIMUM OR AS REQUIRED BY LOCAL ENERGY CODE) IN ATTICS AND OTHER UNCONDITIONED SPACES. AIR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL FF. HUNG FROM THE TOP CHORDS OF THE JOISTS. REFRIGERANT PIPING DRAWINGS SHALL BE CAUSE FOR REJECTION OF THE ENTIRE CONNECTORS ARE NOT ACCEPTABLE. FLEX DUCT DIAMETER SHALL MATCH DEVICE NECK DIAMETER. PROVIDE ROUND GALVANIZED SUBMITTAL. STEEL DUCT RUNOUTS TO MAINTAIN A MAXIMUM FLEXIBLE DUCT LENGTH OF 8'-0". FLEXIBLE DUCTWORK SHALL BE INSTALLED AS 6. WHERE MAXIMUM OPERATING PRESSURE IS GREATER THAN 150 PSIG IN ANY SYSTEM, CONTRACTOR SHALL FURNISH AND 18. REFER TO ARCHITECTURAL PLANS FOR FLOOR AND CEILING ASSEMBLY UL RATINGS AND DETAILS. STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. L PRODUCTS, PIPING, VALVES, FITTINGS, AND ACCESSORIES WITH PRESSURE CLASSIFICATIONS THAT ARE SUITABLE 3. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S 19. SLEEVE ALL WALL PENETRATIONS. SLEEVE INTERSTITIAL SPACE. PROVIDE 22-GAUGE METAL ANGLES PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. FOR SERVICE. RECOMMENDATIONS. INSTAL AROUND DUCT PENETRATION THROUGH WALLS EXPOSED TO VIEW. 6. ROUND AND FLEXIBLE SUPPLY AIR DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH A SPIN IN FITTING WITH SCOOP AND 4. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF 20. PROVIDE 5OF MINIMUM DEADBAND FOR SYSTEMS THAT CONTROL BOTH HEATING AND COOLING. BALANCING DAMPER. WHERE INSTALLED ABOVE INACCESSIBLE CEILINGS, THE DAMPER SHALL BE IN THE NECK OF THE AIR DEVICE. INSULATION, ONE YEAR AFTER OWNER OCCUPANCY. 7. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. 1. DUCT INSULATION: 21. PERFORM WHOLE BUILDING PRESSURIZATION TESTING PER ASTM E779 OR ASTM E1827 BY AN A. DUCT WRAP SHALL BE UL LISTED FIBERGLASS BLANKET INSULATION WITH FOIL VAPOR BARRIER. PUNCTURES AND TEARS 5. ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 4-YEAR MANUFACTURER'S INDEPENDENT THIRD PARTY. MEASURED AIR LEAKAGE RATE OF THE BUILDING ENVELOPE SHALL NOT 8. EXTERNAL STATIC PRESSURE (ESP) DOES NOT INCLUDE COIL, CASING OR FILTER PRESSURE OR IN THE FOIL JACKET SHALL BE PATCHED WITH FOIL TAPE T I WARRANTY FOR A 5-YEAR WARRANTY. EXCEED 0.25 CFM/FT2 UNDER A PRESSURE DIFFERENTIAL OF 0.3 IN. WC, WITH THE CALCULATED OP 10 MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER. SURFACE AREA BEING THE SUM OF THE ABOVE AND BELOW GRADE BUILDING ENVELOPE. A REPORT INSULATE SHEET METAL DUCTWORK IN THE THICKNESS AND DENSITIES AS LISTED BELOW. 6. INSTALL ROOF MOUNTED OUTDOOR AIR CONDITIONING EQUIPMENT LEVEL ON INCLUDING TESTED SURFACE AREA, FLOOR AREA, AIR BY VOLUME, STORIES ABOVE GRADE, AND 9. INSTALL FIRE DAMPERS IN ALL RATED WALLS, FLOOR AND CEILING PENETRATIONS. FIRE DAMPERS SHALL BE THE DYNAMIC TYPE i. SHEET METAL SUPPLY AND RETURN DUCTWORK IN NON -AIR CONDITIONED AREAS: 2.2 THICK 3/4 LB T3 DENSITY STRUCTURAL RAIL SYSTEMS OR CURBS. MOUNT ALL EQUIPMENT ON NEOPRENE PADS. LEAKAGE RATES SHALL BE SUBMITTED TO THE CODE OFFICIAL AND THE BUILDING OWNER. WITH BLADES OUT OF THE AIR STREAM WHERE POSSIBLE. (MIN R-8) IF ALL ROOF TOP MOUNTED EQUIPMENT SHALL BE INSTALLED PER DETAILS AND AS RECOMMENDED BY THE MANUFACTURER, SHEET METAL SUPPLY AND RETURN DUCTWORK IN AIR CONDITIONED AREAS: 2.7'THICK, 1-1/2 LBIFT3 DENSITY (MIN R-6) MECHANICAL/ELECTRICAL COORDINATION: 10. INSTALL SMOKE DAMPERS IN ALL DUCT PENETRATIONS THROUGH A SMOKE RATED WALLS, WHERE DUCTS PENETRATE WALLS THAT III. SHEET METAL OUTSIDE DUCTWORK IN NON -AIR i,,'DNDITIONED AREAS: 2.2" THICK, 3/4 LB/FT3 DENSITY (MIN R-8) CARRY BOTH FIRE AND SMOKE RATINGS, THE DAMPERS INSTALLED SHALL BE COMBINATION FIRE AND SMOKE DAMPERS. ALL 7. PORTIONS OF DUCTWORK AND PIPE INSULATION VISIBLE THROUGH AIR DISTRIBUTION 1 CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL DAMPERS SHALL BE U.L. 555 AND OR 5558 LABELED. iv. SHEET METAL OUTSIDE AIR DUCTWORK IN AIR CONDITIONED AREAS: 2.7'THICK, 1-1/2 LB/FT3 DENSITY (MIN R-8) B. SHEET METAL SUPPLY AND OR RETURN AIR DUCTWORK INDICATED TO BE INTERNALLY LINED IN LIEU OF EXTERNAL DUCT L DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR 11. DUCT ACCESS DOORS: PROVIDE ACCESS DOORS IN DUCTWORK AT EACH FIRE AND SMOKE DAMP LOCATION. EXPOSED IN FINISHED AREAS SHALL BE LINED. 1 -6. SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN 8. MOUNT TOP OF THERMOSTATS AND SENSORS 4'-0" AFF UNLESS NOTED OTHERWISE. THEREIN. SHOP DRAWING SUBMITTAL SHALL CLEARLY STATE THAT THE ELECTRICAL ER WRAP SHALL BE LINED WITH 1-1/2" THICK 3 PCF FIBERGLASS DUCT LINER BOARD (M N MUM R 5). INSULATED DUCTS BEADACOMPLIANT. LOCATIONS OF GRILLES, REGISTERS, AND DIFFUSERS SHOWN ON THE DRAWINGS ARE APPROXIMATE. COORDINATE EXACT 2. PIPE INSULATION: PROVIDE CLEAR LOCKING GUARD ASSEMBLIES FOR ALL OPEN AREA THERMOSTATS. CHARACTERISTICS OF ALL EQUIPMENT HAS BEEN COORDINATED WITH THE ELECTRICAL12. COORDINATE THERMOSTAT LOCATIONS WITH OTHER TRADES. ALL THERMOSTATS SHALL DOCUMENTS AND THE ELECTRICAL CONTRACTOR. CONTRACT LOCATIONS WITH LIGHTS, CEILING GRID, ETC. AND ARCHITECTURAL REFLECTED CEILING PLAN. 2. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT 13. ALL DUCTWORK IS LOW PRESSURE AND LOCATED IN CONDITIONED SPACE. A. REFRIGERANT SUCTION PIPING SHALL BE INSULATED %VITH 1-1f2" THICK FLEXIBLE ELASTOMERIC TUBING INSULATION, AP 9. ALL WORK SHALL BE COORDINATED AND PERFORMED WITH PRIOR APPROVAL FROM SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON -FUSED W APRMAFLEX PIPE INSULATION MANUFACTURED BY ARMACEL OR EQUAL. INSULATION SHALL BE SLID OVER PIPING FROM THE OWNER TO SUIT HIS OPERATING CONDITIONS. WORK IN HAZARDOUS AREAS SHALL EQUIPMENT CHARACTERISTICS, MANUFACTURER I WITH COMMISSIONING, ONE END BEFORE PIPE ENDS ARE JOINED AND SHALL NUT I BE PERFORMED IN ACCORDANCE WITH OWNER'S REQUIREMENTS. 'S RECOMMENDATIONS AND THE ELECTRICAL OT BE SLIT OR CUT. ALL JOINTS AND SEAMS SHALL BE SEALED DR.;%'A(INGS. WEATHER -TIGHT. FINISH COAT FOR FLEXIBLE ELASTOME-_R!C INSULATION INSTALLED OUTDOORS SHALL BE WATER -BASED LATEX ENAMAL DESIGNED FOR USE OVER ALL FORMS OF FLEXIBLE ELASTOMERIC INSULATION. FINISH COAT SHALL 1 ALL MECHANICAL SYSTEMS, EQUIPMENT, AND CONTROLS FOR WHICH THE WSEC REQUIRES CONTROL FUNCTIONS AND OR PROVIDE A PROTECTIVE FINISH SUITABLE TO BOTH INDOOR AND OUTDOOR APPL CAT APPLICATIONS, FORMULATED 10. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE 3. ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, CONFIGURATION TO PERFORM SPECIFIC FUNCTIONS ARE REQUIRED TO BE COMMISSIONED. WEATHER FLEXIBILITY TO RESIST CRACKINGAND WEATHER -RESISTANT TO ULTRAVIOLET (UV) AND OZONE. COATING SHALL COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING DEVICES, ETC.) NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE 2. COMMISSIONING IS REQUIRED PER C408 FOR ALL APPLICABLE MECHANICAL SYSTEMS BE ARMAFLEX We FINISH OR EQUIVALENT. CONDITIONS. I I LATED FOR COLD MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED ACCORDING TO CODE REQUIREMENTS. 11. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND 3. A COMMISSIONING REPORT OR COMPLIANCE CHECKLIST SHALL BE COMPLETED BY THE CX PROFESSIONAL AND PROVIDED TO THE AUTOMATIC TEMPERATURE CONTROLS BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. SUBMIT 4. UNLESS NOTED OTHERWISE, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL OWNER PRIOR TO THE FINAL MECHANICAL INSPECTION. 1. ALL MECHANICAL EQUIPMENT BE CONTROLLED PER SEQUENCE OF OPERATIONS ON SHEET M-0.1 CERTIFIED (AABC OR NEBB) TESTING AND BALANCING REPORT TO THE MECHANICAL SYSTEMS SHALL BE FURNISHED WITH THE EQUIPMENT IT SERVES AND INSTALLED BY ENGINEER/ARCHITECT. 4. AIR AND FLUID FLOW RATES SHALL BE TESTED AND BALANCED WITHIN THE TOLERANCES DEFINED IN THE SPECIFICATIONS; SYSTEMS THE MECHANICAL CONTRACTOR. MOTOR STARTERS FOR HVAC EQUIPMENT SHALL BE FURNISHED SHALL BE BALANCED IN A MANNER TO FIRST MINIMIZE THROTTLING LOSSES, THEN ADJUSTED TO MEET DESIGN FLOW CONDITIONS. WITH THE MOTOR OR APPARATUS WHICH IT OPERATES. MOTOR STARTER INSTALLATION SHALL BE BY 12. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL THE DIVISION 26 CONTRACTOR. EQUIPMENT, DUCTWORK, PIPING, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITOUT WRITTEN PERMISSION FROM THE ARCHITECTS. ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING HOR OTHERWISE ALTERING DUCT SMOKE DETECTORS FIL I ALL FANS SUPPLYING MORE THEN 2000 CFM OF AIR TO ANY SPACE SHALL BE INSTALLED WITH A N"", SMOKE DETECTOR IN THE RETURN AND SUPPLY DUCTWORK UNLESS OTHERWISE INDICATED. DUCT 13. ALL PIPE AND DUCT PENETRATIONS OF FIRE AND/OR SMOKE -RATED ASSEMBLIES SHALL SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN/SUPPLY AIR PATH OF AIR DISTRIBUTION eM,`t I OR APPROVED EQUAL. GREATER THAN 2000 CFM. BE FIRE -STOPPED AS REQUIRED TO RESTORE THE ASSEMBLY TO ITS ORIGINAL SYSTEM UTILIZING A COMMON SUPPLY AND OR RETURN AIR PLENUM WITH A COMBINED CAPACITY INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE MANUFACTURED BY TREMCO. HILTI, 3M 2. 'HE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND a SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED BY THE FIRE ALARM CONTRACTOR U.N.O., MOUNTED IN THE DUCT BY MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. OA REVISION N- RECEIVED CITY OF WKWILA MAY 01 2020 PERMIT CENTER Mll,p 0 17 6 0 Co x 0 0 2 F_ Of LLI R2QUiRED FOR: memmical Electrical Pl,p-nbilng G J- P,oing cilyof-Lwila D!V1 S! ON REVIE Iv:.- I: o - CODE COkIPLIANCE APPROVED MAY 0]02(1 j -ItY Of Tukwila I BUILDING DIVISION TEI #: 19-413 PM: JV CHECKED BY. PKRIANT ISSUED: 04/17/20 MECHANICAL NOTES AND LEGENDS M-0. 1 NOTE ALL PVC ON EXTERIOR O AC AC OF BUILDING To BE SCHEDULE 80. ECONOMIZER 'a7 ECONOMIZER 2) PAINT ALL METAL & HOOD HOOD 17-f PVC PIPING EXPOSED TO TRANSITION FROM FULL SIZE OF UNIT WEATHER. OPENINGS TO FULL SIZE OF DROP BOX INTAKE. PROVIDE FLEXIBLE INSTALL SUCH THAT BOX IS CENTERED CONNECTION FOR y BETWEEN THE BAR JOIST AT ESFR SPRINKLER SUPPLY AND RETURN SUPPLY, LINES. RETURN DROP (TYP.) PROVIDE ROOF ROOF CURB PROVIDE ROOF OF FLASHING T_ CONDENSATE ROOF FLASHING (TYP.) ❑ ROOF SHING(TYP.) CONNECTION TO VENT PENETRATION AC RA/ TOP VIEW VENT 2606 VENT X/ ROOF RA I f PENETRATION] COVER OPENING ENTIRE LENGTH OF SUPPLY AIR WITH 1/7'xl/Z' DUCT SHALL BE INSULATED HARDWARE CLOTH, WITH 1-1/7LINER. Iso PROVIDE DECKTITE 0.13F'VVIRE. FOR ROOF SIDE VIEW DOWN FROM S PENETRATION TERMINATE VENT BELOW FULL SIZE 46Z HORIZONTAL (TYP.) PLANIZEPER CONDENSATE OUTLET RETURN DUCT FROM AC UNIT BOLT TWO B-LINE B24 STRUTS 1-112"MIN ON BOTTOM CHORD OF BAR PENETRATE ROOF HERE JOIST. SUPPORT SUPPLY TWO BLADES EACH AND RUN PIPE T ;e� DUCT FROM STRUTS. 20* OUT FROM SUPPLY UCT INTD TRUSS 1-1112" MIN VERTICAL SPACE OUTLET FROM INTERNALLY LINED 4-WAY DUCT TO BE AC UNIT DIFFUSER PACKAGE. SUPPORTED BY PROVIDE 20" X 10" TUTTLE ANCILLARY AC CONDENSATE PIPING DIAGRAM & BAILEY STRJ DRUM FRAMING. SCALE- N.T.S. LOUVER AT 1,25G CFM. FKIDUCT SMOKE DETECTOR [W]suppo-RT sox WITH B-LINE FOR SYSTEMS 2,000 CFM THREADED ROD, AND ABOVE AND SERVING TURNBUCKLE AND J-HOOK AT MORE THAN ONE SPACE- EACH CORNER. PROVIDE 1/8" PROVIDED BY FIRE SAFETY CABLE AT EACH PROTECTION CONTRACTOR BRACKET CONNECTED TO INSTALLED BY M.C. BAR JOIST. WAREHOUSE DIFFUSER DETAIL SCALE: N.T.S. I CONICAL SPIN -IN SUPPLY DUCT PER DETAIL 10 M VOLUME DAMPER 4) ROOF CURB ROOF FLEX AIR CONNECTOR 10'MAX. I DUCT SMOKE DETECTOR SUPPLY SA ] FOR SYSTEMS 2,000 CFM - NIU AND ABOVE AND SERVING MORE THAN ONE SPACE. NYLON TIE -STRAPS PROVIDEDBYFRE PROTECTION CONTRACTOR INSTALLED BY M.C. LAY-INCEJLING DUCTS MUST RUN STRAIGHT DOWN DIFFUSER PERPENDICULAR TO FLOOR, FROM ROOF TO TOP OF STRUCTURE DUCTS TO BE INTERNALLY INSULATED FOR RUN BETWEEN BUILDING ROOF AND ANCILLARY FRAMING DIFFUSER INLET DETAIL SCALE N.T.S. LIGHTS CEILING TYPICAL ANCILLARY STRUCTURE (BREAK ROOM, OFFICE, TRAINING ROOM) ROOF MOUNTED AC UNIT DETAIL SCALE N.T.S. O O NOTE' FAN BLADES NOT NOTE: AN BLADES NOT 7 PERMITTED TO EXTEND NOTE: ]BELOW LIGHTING FIXTURE INTERCONNECT FANS TO FIRE ALARM SYSTEM TO SHUT DOWN FAN PER NFPA 72 HVLSFM AIR FOILS 36'AFF INSTALLED HEIGHT NOTE: LIGHTING FIXTURE FAN BLADES NOT PERMITTED TO EXTEND BELOW LIGHTING FIXTURE FINISHED FLOOR O O *nL�.FAN PLACEMENT MOUNTING DETAIL *Et N CENTRIFUGAL EXHAUST FAN, SEE SCHEDULE NOTE SECURE -FAN TO CURB WITHI#10 TEK SCREWS 170C. (MtN 2 PER SIDE) FABRICATE BIRD SCREEN DROP -IN DAMPER TRAY AS REQUIRED. FAN BASE SIZE & MATERIAL TO MATCH DUCT. 1/3 FAN BASE MIN. CURB SEE 8"MIN. SCHEDULE FOR PROVIDER SHEET METAL EXHAUST GRAVITY BACK DUCT UNLESS OTHERWISE DRAFT DAMPERNOTED ON PLANS SIZE To MATCH DUCT. ROOF EXHAUST FAN 15 SCALE: N.T.S. — - - - - - - - - - — FAN MOUNT SCALE NTS IAX SAFETYCABLE (4) GUY WIRES MOUNT FAN PER MANUFACTURER'S INSTRUCTIONS MINIMUM 3070 NEAREST FAN 36' MIN, SEPARATION J TRUSS, BY MBSS DISTANCE BETWEEN FAN BLADES AND EQUIPMENT 1/4' STEEL PLATE WALL KEYPAD CONTROLLER STEEL PLATE (SPEED CONTROLLER) SCALE: NTS INTEGRATE WITH BMS — — — — — — — — — ml� LOCKABLENENTED ENCLOSURE, MOUNT 7 FEET ABOVE FINISHED FLOOR, SEE PLAN FOR LOCATIONS �p x 0 0 LLI .......... REVIEiAjjj 4, CODE COMPLIANCE APPROVED DEC 22 2020 City of Tukwil a BUILDING DIVISION RECEIVEC CITY OF TUKVV�: TEI#: 19-413 DEC 2 1 zc2q PM: Jv PERMIT CHECKED BY: PKR/ANT ISSUED: 04/17/20 MECHANICAL DETAILS M-3.1 Air Terminal Schedule Symbol Manufacturer Model Type Serves Notes CD TUTTLE & BAILEY SQD SUPPLY BREAK ROOM 1 CD TUTTLE & BAILEY SQD SUPPLY CONFERENCE ROOM 1 CD TUTTLE & BAILEY SQD SUPPLY HR WORKROOM 1 CD TUTTLE & BAILEY SQD SUPPLY OPEN WORKROOM 1 CD TUTTLE &BAILEY SQD SUPPLY OPTIONAL WORKROOM 1 CD TUTTLE & BAILEY SQD SUPPLY STATION MANAGER WORKROOM 1 CD TUTTLE & BAILEY -& SQD SUPPLY TRAINING ROOM 1 EG-1 TUTTLE BAILEY -& CRE500 EXHAUST ELEC. ROOM 1 EG-1 TUTTLE BAILEY CRE500 EXHAUST JANITOR ROOM 1 EG-1 TUTTLE &BAILEY -& CRE500 EXHAUST RESTROOM 1 RG TUTTLE BAILEY -BAILEY PR RETURN BREAK ROOM 1 RG TUTTLE & PR RETURN CONFERENCE ROOM 1 RG TUTTLE & BAILEY -& PR RETURN CONTEMPLATION ROOM 1 RG TUTTLE BAILEY -& PR RETURN HR WORKROOM 1 RG TUTTLE BAILEY -& PR RETURN NEW MOTHERS 1 RG TUTTLE BAILEY PR RETURN OPEN WORKROOM 1 RG TUTTLE &BAILEY PR RETURN OPTIONAL WORKROOM 1 RG TUTTLE & BAILEY PR RETURN STATION MANAGER WORKROOMA 11 RG TUTTLE & BAILEY PR RETURN TRAINING ROOM 1 1. FRAME STYLE TO MATCH ARCHITECTURAL CEILING TYPE. Exhaust Fan Equipment Schedule - S.I.C. Symbol Manufacturer Model Serves Weight HP Voltage Phase Notes EF-1 COOK ACED135D (VF) RESTROOM 72.00 Ibf 3/4 115 V 1 (1) (2) (3) (4) OF-2 COOK ACED135D (VF) RESTR0 M 72.00 Ibf 3/4 115 V 1 (1) (2) (3) (4) EF 4 COOK GC-168 REMOTE RESTROOM 12.00Ibf 52.5W 115 V 1 (2) BF 3 COOK GC-168 REMOTE RESTROOM 12.00 Ibf 52.5W 115 V 1 (2) 1. PREFABRICATED INSULATED ROOF CURB PROVIDED BY G.C. 2. FAN OPERATION TO BE INTERLOCKED WITH TIME CLOCK. SEE PLANS FOR TIME CLOCK LOCATION. 3. PROVIDE BIRD SCREEN. 4. PROVIDE FAN SPEED CONTROLLER MOUNTED IN ACCESSIBLE LOCATION NEAR EQUIPMENT. ELECTRIC HEATER SCHEDULE Symbol Manufacturer Model Serves Heat Output Voltage Phase Notes ECH-1 Marley Engineered Products CDF-558 WOMENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-2 Marley Engineered Products CDF-558 WOMENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-3 Marley Engineered Products CDF-558 MENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-4 Marley Engineered Products CDF-558 MENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-5 Marley Engineered Products I AWH4404F SPRINKLER ROOM 3 KW 208 V 1 (1) (2) (3) 1. COLOR SELECTED BY ARCHITECT. 2. INTEGRATED TAMPER PROOF THERMOSTAT. 3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4. PROVIDE WITH CDF-RE RECESS ENCLOSURE AND CDF-TK TRIM KIT. VENTILATION AIR TABLE HVAC UNIT AREA SERVED OCCUPANT LOAD REQUIRED VENTILATION REQUIRED OUTSIDE AIR (CFM) DESIGN OUTSIDE AIR (CFM) NOTES AC-1 HR WORK 1 (107 SF) 5 CFM/PERSON 0.06 11 ROOM (105) CFM/SF OPEN 8 (762 SF) 5 CFM/PERSON 0.06 86 WORKROOM CFM/SF CON CONFERENCE 18 (413 SF) 5 CFM/PERSON 0.06 105 ROOM (107) CFM/SF OPTIONAL 1 (134 SF) 5 CFM/PERSON 0.06 t3 WORKROOM CFM/SF (108) STATION 1 (192 SF) 5 CFM/PERSON 0.06 17 i MANAGER CFM/SF ROOM (109) TOTAL OUTSIDE. AIR 232 235 AC-2,3 BREAK ROOM 306 (7,402 SF) 5 CFMiPERSON 0.12 2,418 (104) CFM/SF NEW MOTHERS 1 (50 SF) 5 CFM/PERSON 0.06 8 ROOM(110) CFM/SF CONTEMPLATION 1 M SF) 5 CFM/PERSON 0.06 S ROOM (111) CFM/SF TOTAL OUTSIDE AIR 2;434 2,470 '4C-4 TRAININGROOM 17 (1,007 SF) 10 CFM/PERSON 0.12 291 (103) CFM/SF TOTALOUTSIDE AIR 291 295 AC-5-12 WAREHOUSE 330 (187,380 SF) 0.06 CFM/SF 11,243 TOTAL OUTSIDEAIR 11.243 11,280 EF-1 WOMEN'S TOILET 16 WC 70 CFM EXHAUST PER 1,260 (113) WC/U TOTALOUTSIDEAIR rIECEIVED CITY OFIul% eR-A MAY Ol 7070 PERMIT CENTER x� F`LU^ VJ W � I I m m rn� m W 7wFz�w e z0 C� ��rxawE- 3e gg _ I VA I EVIc J, _I' O CODE CO PLIANCE] APPROvEo I I City of Tukwila BUILDING DIVISION j TEI #: 19-413 PM: JV CHECKED BY: PKR/ANT ISSUED: 04/17/20 MECHANICAL SCHEDULES M-0.2 OVERALL MECHANICAL PLAN SCALE: 1/32" = V-0" RECEIVED CITY 0F''UK%1ILA MAY 01 2020 PERMIT CENTER MIR-aly RE7=gPLIAN rO COD'CEVEDr MAY 2 0 2020 City of Tukwila BUIDIVISION rN� TEI #: 19-413 PM: JV CHECKED BY: PKR/ANT ISSUED: 04/17/20 OVERALL MEC M-1.1 �S�, R STATION CONFERENCE OPTIONAL MANAGER ROOM WORKROOM WORKROOM 107 108 109 8/8 C-4— __0 190 CFIIM�, II 1 12/12 CD-4 -g^ 0 10/10 CD-4 12112 CD-4 10" o 10" o 405 CFM VD 10"o VD 245 CFM 405 CFM mI I I I „0 2424 I I I� VD VD m 24n4 MOD NECK 24n4 T, � 1 � MODULE RG iv 24/24 RG 14"0 RG RAJ / VD 112'X12" -VD - - 1.3 OPEN i _ 10"0 = ® 8"0 WORKROOM_ 9 19°0� I 6„e HR W012!£AOC]6A 1 10/10 CD-4 10/10 CD-4 e/8 CD-4 105 315 CFM 315 CFM 125 CFM 24n4 RG 16/16 NECK 2424 MODULE RG (TYP. OF 4) r-- - - - - - - --'Al- - 1.6 14/14 CD-4 FYI, 850 CFM 14/14 CD-4 - 14/14 CD-0 850 CFM 850II CFM F IIM. I-• =14"0 _14"m. _=14"0 VD VD VD �� 6926 SUPPLY & 76n0 16"x16" 26"x24" RETURN RUN DUCT STRAIGHT DOWN TO VD VD VD TOP OF CEILING I I .� STRUCTURE SEE DETAIL 10 3 14"a 14''a 14"e I? I( (it i fl - i If - 14/14 CD-4 ® 14114 CDC ® 14/14 CD-4 li 850 CFM 800 CFM 850 CFM i NOTE: DDC CONTROL TOPREVENT SIMULTANEOUS HEATING AND If> COOLING OF BREAK jf ROOM. BREAK ROOM 104 14/14 CDC - 14/14 CD-4 14114 CD-4 650 CFM 650 CFM 650 CFM ` -14"0 VD-14"0 VD-14"0 1, VD - 18"x18" 26"x24" A3 6926 SUPPLY & 7620 " RETURN RUN DUCT 1 VD yp STRAIGHT DOWN TO TOP OF CEILING ill STRUCTURE SEE i DETAIL 10 o ) N 'v v \ 16/16 NECK 2424 I_, \ MODULE RG i (TYP. OF 4) It _ VD 14114 CD-4 14114 CD-4 - 14114 CD-4 650 CFM - 650 CFM ® 650 CFM b ,o fire CD-4 $ana RG 150 CFM VD NEW MOTHERS - seI 110 LOCKERS 10"0 102 m 's 8"0rg 3424 RG VD � VD v I a/acD.i CONTEMPLATION 150 CFM ROOM I 111�, BREAK ROOM HVAC PLAN SCALE: 1/8" = 1'-0" REMOTE TOILET HVAC PLAN SCALE 1/8" = 1'-0" ELECTC EF CH S EXHAUSTF AN 15 1 RE ESSED CEILING R 16l16 DUCT UP MOUNTED HEATER UNIT ON ROOF (TYP. OF 4) fly'o VD � 1010 cD a — — — — 14/14 EG t WOMEN'S TOILET ENTRY 2so cFnn s 14" 0 CDC Do eFM ® 113 3"5 VESTIBIJ600 CFM JVD AIR DAMPER PRODUCTS . _-- - MODEL: BCDR (BC3) VOLUME DAMPER WITH E2424 RG 10"0 2424 RG _ [.,....,.. t REMOTECABLE 7VD ADJUSTMENT. (TYP. OF 6) j N DAMPER CONTROLLER 2424 RG 3 'D - 3 INSTALLED IN CEILING € WITH COVER PLATE. 14/14 EG-1 CH (TYP. OF 6) SEE DETAIL 1 90D CFM 2 ' (TYP.) 10/10 CD-0 % VD 10"0 �' CH 3D0 CFM 13 VD (TYP. OF 4) + a€ _ 900 CF G-1 3 - C4) VD 12"0 12're VD 9A0-CEdA - I MEWS TOILET a AP 10"0 I VD A4 18/16 SUPPLY &24/14 I: _ �/ RETURN RUN DUCT i TRAINING ROOM I STRAIGHT DOWN TO V TOP OF CEILING / / 103 14/14 EG-1 V CH STRUCTURE SEE 900 CFM 4 + E EF DETAIL SEE DETAIL 15 10 i t 2 EXHAUST -FAN ____ ..,.._-_ .. . .._. ..-..._-_...,... .. 16/16 DUCT UP TO UNIT ON ROOF g^0 VD 6/6 EG-1 t '100 CFM ; TRAINING ROOM HVAC PLAN SCALE: 1/8" = 1'-0" nECEIVEn CITY OF fL;KVJILA MAY 01 2010 PERMIT CENTER W11qvy m T � z i � ,r Wo3�rnw i a eowaz s zrw,F-Ej z, w sF -E e wt s ig a� O F1 m X Pm REV° 3 E ` ; CODE C6 ,; PLIANCE APPROVED I MAY 2. 0 7.0?.0 City of Tukwila BUILDING DIVISION �N TEI #: 19-413 PM: JV CHECKED BY: PKR/ANT ENLARGED HVAC P M-2.1 NOTE: 1) ALL PVC ON EXTERIOR OF BUILDING To BE SCHEDULE 80. ECONOMIZER \Aj CONOMIZER 2) PAINT ALL METAL & HOOD OD PVC PIPING EXPOSED TO TRANSITION FROM FULL SIZE OF UNIT WEATHER. OPENINGS TO FULL SIZE OF DROP BOX INTAKE. PROVIDE FLEXIBLE RETURN INSTALL SUCH THAT BOX IS CENTERED CONNECTION FOR SUPPLY, BETWEEN THE BAR JOIST AT ESFR SPRINKLER SUPPLY AND ik LINES. 7 RETURN DROP (TYP.) PROVIDE ROOF ROOF CURB P OVIDE ROOF FLASHING (TYP.) SHING (TYP.) CONDENSATE ROOF ROOF [A] CONNECTION TO VENT PENETRAT(ON VENT VENT AC 9 RA/ TOP VIEW r 26n6 ROOF RA PFNETRATI COVER OPENING ENTIRE LENGTH OF SUPPLY AIR WITH 1/2"xl/2" DUCT SHALL BE INSULATED HARDWARE CLOTH, WITH 1-1r2'LINER. PROVIDE DECKTITE -- SIDE VIEW 0.135"WIRE. FOR ROOF � r DOWN FROM PENETRATION TERMINATE VENT 13EL FULL SIZE :7�// �,�z SIZE PER CONDENSATE OUTLET RETURN DUCT HORIZONTAL (TYP.) PLAN FROM AC UNIT BOLT TWO B-LINE 824 STRUTS 1-112"MIN ON BOTTOM CHORD OF BAR JOIST. SUPPORT SUPPLY 0. TWO BLADES EACH PENETRATE 0 ERE DUCT FROM STRUTS. 20* OUT FROM AND PUN PIPE TO SUPPLY UCT INTO TRUSS 1-1/TMIN VERTICAL SPACE OUTLET FROM INTERNALLY LINED 4-WAY AC UNIT DIFFUSER PACKAGE- UCT TO BE PROVIDE 20" X 10" TUTTLE UPPORTED BY AC CONDENSATE PIPING DIAGRAM & BAILEY STRJ DRUM A CILLARY SCALE N.T.S. LOUVER AT 1,250 CFM. F MING. [A]DUCT SMOKE DETECTOR [BJSUPPORT BOX WITH B-LINE FOR SYSTEMS 2,000 GEM THREADED ROD, RA AND ABOVE AND SERVING TURNBUCKLE AND J-HOOKAT cc P C UC UP C MORE THAN ONE SPACE. EACH CORNER. PROVIDE 1/8" PROVIDED BY FIRE SAFETY CABLE AT EACH PROTECTION CONTRACTOR BRACKET CONNECTED TO INSTALLED BY M.G. BAR JOIST. (o 2�WAREHQUSE DIFFUSER DETAIL LIGHTS )SCALE: N.T.S. F. 4�K \Aj CONICAL SPIN -IN SUPPLY DUCT PER DETAIL 10 ROOF CURB VOLUME DAMPER (9mo ROOF FLEX AIR CONNECTOR SUPPLY SA 0 DUCT SMOKE DETECTOR FOR SYSTEMS 2,000 GEM DUCT AND ABOVE AND SERVING MORE THAN ONE SPACE. PROVIDED BY FIRE. NYLON TIE -STRAPS PROTECTION CONTRACTOR INSTALLED BY M.C. LAY -IN CEILING DUCTS MUST RUN STRAIGHT -DOWN DIFFUSER PERPENDICULAR TO FLOOR, FROM ROOF TO TOP OF -STRUCTURE DUCTS TO BE. INTERNALLY INSULATED FOR RUN BETWEEN BUILDING ROOF AND ANCILLARY FRAMING 1SCAUER l4LET DETA�_ N.T.S. I MOUNTED AC �QNIT UNIT BIRD SCREEN FAN BASE 1l3 FAN BASE MIN. CURB SEE SCHEDULE FOR PROVIDER GRAVITY BACK DRAFT DAMPER. SIZE TO MATCH DUCT. ( 5)ROOF EXHAUST FAN Plo RLVic jv ODE COi";PLIANCE APPIROvED MAY 2 0 2020 1 City of Tukwila BUILDINGDIVISION 1 TO #: 19-413 PM: Jv CHECKED BY: PKR/ANT rIECEWEE) crry of-'fUl.,L141LA ISSUED: 04/17/20 MECHANICAL DETAILS MAY 01 200 PERMIT CENTER M-3.1 NW NE SW SE CONM- PLLS lade 32 0- CLM CL- U- -TIL 3 Ill 71 I E. DOOR 30 Il1 .1 '2 trle . P- cm cLTOLF c- """cLm CIT GU - ORIENTATION aHGo cLF 214 o no- 1i o so- 1. 11-1h. EOWPMERT 011ke il. 201 RODE TOPIEMPERATUREFALTOR8 WATTS NW NE SW 8 WIND GIR ..UUU TT.T1N HTl.AT- ON[W 1-31 t 0- CL= C- M'VN I I .'I. 2 4.2 32 ae lO.TH� lo 2 T,.11 2 8.2 _U., '3 -1. 7 14 2 - N 1 1.2 2 1. 3 - .DOOR 36 2 3112 R- I-. 3 sex Ion- -N-. OLT11) I-- CLT"' .N- 4 3 4.8 G- --ON I PillcLF H10- TAL - o's EAST214 o I . 37 012 WEsf 214 0A WILT. 11. P. U-ING & - 41- GNN AW R.1- LIGIIIING u- -oum o . '.- III IIOII -RI Oo1ARCoN.E� SPACE: MAIN SALES Cab. by: Jv Oobod. m 792 m�� 623 V.I...(ft-3) 7.�.XK) PiPpot Deffro* - Oxbow In.d.DOT, 0 �l 63.5 A,, Hinght (ft) 40.00 U....: T""" Diiix T 5.8 Country Um in D. -S 4.,-11) Area 0T"2) 187, Toinix.i.io Oeenoibon Sou" A- U atim T-RBWM) No. TIL "" WALL "Er 24.= -11: 0�1 04 �m - IL 10 UPWAUL-' 7,192 -9 .630 44,4M ROLL UP DOOf? 9m 3�2 910 2,M 8 ow WNGING DOOR 2 10 East TILT -UP WALLS , 7W 4.2 OIN 2.962 TILTLUPWAI 1 92 0.830 5,518 ROLL UP DOOR 1.� 102 0� 10 11,685 SWINGING DOOR 48 101 0067 33 si,utti TILT UP WALL "I 26'066 4.8 0.104 -13.012 TILT UP WALL 'C' 7,681 -1.8 O.:W �,710 ROLL LIP DOOR 9W 241 0 10 21,14 SWINGING DOOR a 242 0 (W 78 Westl` TlLTLUWALL'IY- 6 JW a 04 4,m TILT-UPWALL V 0 a .630 0 ROLL UP DOOR 1 3:.2 0910 0 SWNGING DOOR 3 2 0.067 0 H.dx..l ROOF Iffim 68.2 0 SIVUGHT 2W 4 : MOKIEVENT 0 4� 06D 0 Total Tonsm-ion -W.122 ""'bilion On-tion S.- Sc sl� CLF Btu Horizonbil Skylight 2M 0.61 146 0.: '1.117 sTo'W"I Solar Rd,b,, Smoke -ft 0 0 IS 1 a 0 :7.ITI].7' Int.-I Loatls P-pW 3W Oon,ixii. 2M "'t gZ500 UgNs OM V&tWft 112.429- 3.41 6.1w 383. Equipment 1.20 vi�holft 224.EIW . 3.41 11 7% HVAC CIA �z ofhi S Temp.Diff. 80,760 , all.fixi 8,000 xh -6 Temp. Diff. MM Toial Intmal Lwd "Wim LPeoplen'U"'I number 33' 200 IlWiPoo. 6"Go r rim 12.893 5 g..WI, OAS 45.925 I , 1.925 IT-1 0 Ing I-P,xis Sensible 11oling P d 202 �,071 Sensible ing b,d wisiffmy ftiomrf 15% 231:SB2 Total 11 1:183,127 ="�g I-.d W.finty 15% Un,380,596 itUnits (Sal equal to highestnxi-) Una n. ntn. -1 capacity of design condlion 47.95 12.5 To, AC - 7.8 Un"' Nominal 1 Wx. 1. .n 1874 ixI fVIPn ,ky light Pimend g, I.. lUna CFM 5," CFM C,tOutside Air 1.612 C� .,in bales 117� EnEnteringEnteringWet 13.1b 13'F EnlxIr,gGmin/bdb c/)W W Li 3: 0 00 X 0 0 0 F- 2 (r Z) LLI c) CCCE ' '01"!PLIA�,110E MAY 2 0 7020 City of Tukvvila BULDING DIVISION TE I #: 19-413 Pm: JV CHECKED BY: PKR/ANT ISSUED: 04/17/20 RECEIVED -f HEATING & COOLING LOADS CiTy of: LiK1VILAi MAY 01 2070 PERMIT CENTER M-4.1 VA 14 AVOVly MEMO ■®® ■E ME= ■E Data 9121/2011 For Building Dept. Use �� 00 �� 00 .. ®0 Supply fan and w,den,er fanom C(dC:_, C' C MINCE Sa F" to 3 MAY 2 i) 20211 a . a City ,f Tu k� I CUIL'7Sisr<y s 7f43 nECEIVEO GITY OE TIjvWtLA TEI #: 19-413 PM: JV CHECKED BY: PKR/ANT ISSUED: 04/17/20 - MECHANICAL ENERGY CODE MAY 012029 PERMIT CENTER M _4.2 General Info Project PROJ-SUM for. Project =2=111, Project compliance join, Project submittals PW-f Title shall match jurisdiction: Pmo., plans 1,11. block. Title: D rmocly-Cxbsnw Street Address S102ad St. Data 9/25/2019 Far Building ..,.drmm1 We City, County, Zip: Tukwila, King, 98168 Owner or Rep Todd Schutz City of Tukwila Project Description Select all that apply to the scope of incilent. Select AddWicu, I Existh, . Existing i ? the existing building willbe combined with the, addition or alteration to demonstrate, complian per Section C502.1 0*6011. New, Construclion and Additions E-:1 New Building El Building Addition Existing Building Retrofito"d.ratic, Ej Alteration ❑ Change of Occupancy ❑ Change in Spam Conditioning Historic Building Building Elements Scope - Salad all that apply El All E] Building Envelope E] Meunammi systems EJ Service Hot Water Systems 0 Lighting Systems E] Electrical Systems Occupancy Type All Commercial 0 Group R - R2. R3, & R4 0 Mixed Use over stones and all RI lifiloced Use - Building is greater than three stories above grade and it has both Commercial and Gicup R occuirnmow. Mixed 2��ujxmc Buildingsthree or less above qte,:nCfit has both Commercial and Select All Man 3., "a"n"t So C.—'dal to of connsfi-ca(or the —erchal ,. ns.,a, =ofthebuddingac spacea, shall comply with li WSEC Residential Provisions. Space Conditioning Categories Select all that apply to the scope oficii EI] Fully Conditioned El Semi-1,aete,12 E] Refrigerated Spaces (AIMM.— andl., Walk-irll) E] Law Energy Space, CatagW Eligible Low Energy Spaces [-] Unconditioned E] L...-Itlyhearb.giou.1mg-piaity, E] ==r ❑ Greenhouse' LJ Equipment building Floor Area and Stories Floor. Above Building Gross Conditioned Floor Area P.jat Gross Conditioned Floor Area Grade 2 19T,497 197,W General Compliance Path 0 Compliance Method I - General Compliance Method 2 -Total Building Complian Mothadl-Pjests shall demonstrate —p r-11,11,pichoalle, Maly sascriptive requiremers, of this code. Refer to C40, 2. ftz I far more j.'aronsfaiMiliern;dfamrs to Pinclude with a Prescriptive submilbalAll applicable ENV, L TG. and MECH. ���2 - Projects ofamplying, via total building performance (TSF) shelf include a summary whale building mode' perSectionC407 and Mail demonstrate compliance with all applicable mandatory n s Code. R, r Section C401.Z It.. 2 — information. Compliance Forms to include will, a Tap submilsel. PROJ-SUM, ENV-CHK, LTG-EXT, LTG-CHK, and all MECH forms except MECH-ECONO and MECH. VENT (pending). in --EZVt;� overlapping shallcoolers and /reea3m 4 for ,,,;%u==. Note 2 - Senni-freated Spaces fine~ with equipment other electric resistance may coke an exemption for wallin amr-1 assemblies shell complywiththe Natorg Greenhouses -Greenhouses are defined as spaces Nat maintain a Specializd Sundt environment i t,ms%r Low Energy Spaces -Low E at ,. .b:eM . applim dons in are Cda tlo apply inGud'rrg IigMing, mechanical, service waMrheaMg. etc. Acon,4- /a aCrdb= For Low Em n ran antins',susdioluadrely cooling, � ,d_y,,mdofhaMequipment .,p,P,-,dthat raq.,a,..n7 condensing unit UJ U) 4 0 �i E— Z z E-0 w 04 P. ul —E rO 0 0 ry LIJ BtjiLi3iNG JDiViSION I TEI #: 19-413 PM: JV CHECKED BY: PKR/ANT nECEIVEO ISSUED: 04/17/20 CITY of: TuyWILA ENVELOPE ENERGY CODE MAY 01 2029 PERMIT CENTER tAR" M-4.3 is Air Terminal Schedule Symbol Manufacturer el Type Serves Notes CD TUTTLE & BAILEY gS§-Q-D SUPPLY BREAK ROOM 1 CD TUTTLE &BAILEY SUPPLY CONFERENCE ROOM 1 CD TUTTLE & BAILEY SUPPLY HR WORKROOM 1 CD TUTTLE &BAILEY SUPPLY OPEN WORKROOM 1 CD TUTTLE & BAILEY ISQD SUPPLY OPTIONAL WORKROOM 1 CD T TLE & ILEY AQD SUPP STATION NAGE RKR OM 1 tt_UTT BAILEY' SQSUPPLY RAF ROW-1 CDF TUTTLE & BAILEY PP SUPPLY DMARC, ELECTRICAL ROOMS 1 EG-1 TUTT E & BA Y CR 500 RUST ELEC. ROOM A 1 1 L All RE ST IT — 1 EG-1 TUTTLE & BAILEY CRE500 EXHAUST RESTROOM 1 RG TUTTLE & BAILEY PR RETURN BREAK ROOM 1 RG TUTTLE & BAILEY PR RETURN CONTEMPLATION ROOM 1 RG TUTTLE & BAILEY PR RETURN HR WORKROOM 1 RG TUTTLE & BAILEY PR RETURN NEW MOTHERS t Manufacturer I Model I Serves HVAC Equipment Schedule Sensible Goofing Total Cooling Cooling Efficiency Heat Input Heat Output Exhaust Fan Equipment Schedule - S.I.C. Symbol Manufacturer Model Serves Weight HP Voltage Phase Notes EF-1 COOK ACED135D (VF) RESTROOM 72.00 Ibf 3/4 115 V 1 (1) (2) (3) (4) (6) EF-2 COOK ACED135D (VF) RESTROOM 72.00 Ibf 3/4 115 V 1 (1) (2) (3) (4) (6) EF-4 COOK GC-168 REMOTE RESTROOM 12.00 Ibf 52..5W 115V 1 (2 -3 C 2 15 1O )2.0- (2 TF-2 COOK 90SQN15D EMERGENCY ELECTRICAL ROOM 55.00 ll f 116 120 V 1 i(4) (5) TF-1 COOK 90SQN10D DMARC ROOM 45.00 Ibf 1/6 120 V 1 (4) (5) WF-1 COOK XWD18 18XW34D152 SPRINKLER 120.00Ibf 314 120V 1 (5)(6) LV-1 RUSKIN ELM6375DX SPRINKLER 120 V (7) LV-2 RUSKIN ELF375DX SPRINKLER (8) 1. FAB DIN D R RB P I CD B 2. FAN ERATION BE INT OCKED H TIME C CK. SEE NS FOR E CLOC OCATIO . 3. PROVIDE BIRD SCREEN. E E OL U AC ES E CATION NEAR EQUIPMENT. 5. OVIDE W H INLET/ UTLET SA ETY SCR N. V 6. PROVIDE GRAVITY BACKDRAFT DAMPER. 7. PROVIDE WITH DAMPER ACTUATOR INTERLOCKED WITH WF-1. 8. SIZE TO MATCH WF-1 WALL OPENING. oaa= Electric Heater Schedule Symbol �ECH-1 Manufacturer Model Serves Heat Output Voltage Phase Notes Marley Engineered Products CDF-558 WOMENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH2 Marley Engineered Products CDF-558 WOMENS RESTROOM 5 KW 208 V 1 (1) (2) (Y) (4) ECH-3 Marley Engineered Products CDF-558 MENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH-4 Marley Engineered Products GDF558 MENS RESTROOM 5 KW 208 V 1 (1) (2) (3) (4) ECH5 Marley Engineered Products AWH4404F SPRINKLER ROOM 3 KW 208 V 1 (1) (2) (3) 1. COLOR SELECTED BY ARCHITECT. 2. INTEGRATED TAMPER PROOF THERMOSTAT. 3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4. PROVIDE WITH CDF-RE RECESS ENCLOSURE AND CDF-TK TRIM KIT. 11 HVLS Fan Schedule Phase © •� . © . ©� - • VENTILATION AIR TABLE HVAC UNIT AREA SERVED OCCUPANT LOAD REQUIRED VENTILATION REQUIRED OUTSIDE AIR (CFM) DESIGN OUTSIDE AIR (CFM) NOTES AC-1 HR WORK 1 (107 SF) 5 CFM/PERSON 0.06 11 ROOM (105) CFM/SF OPEN 8 (762 SF) 5 CFM/PERSON 0.06 86 WORKROOM CFM/SF (106) CONFERENCE 16 (413 SF) 5 CFM/PERSON 0.06 105 ROOM (107) CFM/SF OPTIONAL 1 (134 SF) 5 CFM/PERSON 0.06 13 WORKROOM CFM/SF (108) STATION 1 (192 SF) 5 CFM/PERSON 0.06 17 MANAGER CFMSF ROOM (109) TOTAL OUTSIDE AIR 232 235 AC 2,3 BREAK ROOM 306 (7,402 SF) 5 Cf:WPERSON 012 2,418 (104) CFM/SF NEW MOTHERS 1 (50 SF) 5 CFM/PERSON 0.06 8 ROOM(110) CFM/SF CONTEMPLATION 1(50 SF) 5 CFM/PERSON 0.06 8 ROOM (111) CFWSF TOTAL OUTSIDE AIR 2,434 2,470 AC-4 TRAINING ROOM 17 (1,007SF) 10 CFMIPERSON 0.12 291 (103) 'FM/SF TOTAL OUTSIDE AIR 291 295 AC-5-12 WAREHOUSE 330 (187380 SF) 0.06 CFMSF 11,243 TOTAL OUTSIDE -AIR 11,243 11280 EF-1 WOMEN'S TOILET 18 WC 70 CFM EXHAUST PER 1,260 (113) WCAI TOTAL OUTSIDEAIR 1,260 1,800 QUANTITIES ARE EXHAUSTED EF-2 MEWS TOILET 10 M, a U 70 CFM EXHAUST PER 1,260 (T15) WC/U JANITOR CLOSET NOT OCCUPIED NIA 100 (120) (125SF) ELEC. ROOM NOTOCCUPIED N/A 100 (123) (282 SF) TOTAL OUTSIDE AIR 1,460 2,000 QUANTITIES ARE EXHAUSTED EF-3, 4 MEN'S REMOTE 1 WC, 1 U 70 CFM EXHAUST 140 TOILET PER WC/U WOMEN'S 2 WC 70 CFM EXHAUST 140 REMOTE TOILET PER WC/U TOTAL OUTSIDE AIR 280 300 QUANTITIES ARE EXHAUSTED .REQUIRED OUTSIDE AIR PER IMC 2015 CHAPTER 4. SEPARATE PERMIT REQUIRED FOR: Mechanical r, , t,a • ,..:^a ,. ^max x •+W Waea• ❑ Electrical •1r4rM w,sn h pwy of"* ❑ Plumbing 4 1yinLi&Siudtiva3 .•A ya [�l Gas Piping Revaojs Wilt retl:+ue nm OW I ,y of Tukwila : i 811Q •flay 01CM1� r10QPiMI!8I WMI I DING DIVISION FILE '-Olpy I �MatBaaaw:PBrua�` flc��tisswin•. {i�rori3 n+.;^,fa t ,:.. �. zi aw*w Wx ewWtLx o; JrII•I?fK'! RIGCRtr 0# HIJ[K YF -.. i0 U '•_ pp(Q410n5 YS drk. i?wW'rY,}:,�M, y C+4y uf'rwLa+W au,e.o�nv ut;ns,ar. M I 1- 0 1-74 M S FOR WORK IN THIS AREA SEE BREAK ROOM HVAC PLAN ON SHEET M-2.1. R (Q.5) Q NOTE: CLASS 1 MOTORIZED RATE AND CLASS @1" WG LEAKAGE P OSA DAMPER WITH 3 CFM/SF 1 MOTORIZED RETURN AIR RATE INTEGRAL TO ALL AC N @1" WG LEAKAGE DAMPER WITH 4 CFM/SF UNITS. M L K I ..... F- I I I 3/4 rh I I I I I I _�3/4"i SEE DETAILS 1 10 Al — I I hil— T — — I — — I I — — — I I — — — — 2C SEE DETAILS 1 10 I'I' .... 1 114, C C . AC- 5 EE DETAILS 1 6 1JSTALLfJCO2 2 AC SEE DETAILS 1 1Q (JUCTTURN - 1 1/4° C: 1F SEE DETAIL 15 ------ - --- la®®®®aea 4C SEE DETAILS 1 10 CO 3/4" C AC 9 3 2F SEE DETAIL 15 L J !►�casi — — — — — — I — — — — — ill C FOR WORK IS(TYP.) i AREA SEE TRAINING ;; r• ROOM HVAC PLAN ON Co — — — — — — — — — — — — — — FT (� -1/4" COND. DOWN TO MOP SINK. DAYLIGHT @ G' ABOVE RIM. I INSTALL HVLS MOUNT SUSPENDED LOCATION AND CENTERED BETWEEN COORDINATE BETWEEN FANS FANS PER MANUFACTURER'S FROM THE ROOF TRUSSES. HEIGHT IN FIELD SUCH THAT SPRINKLER HEADS. SPRINKLER WITH OTHER TRADES AND MAINTAIN OF A MINIMUM OF 30 FT. (TYP.) RECOMMENDATIONS AND COORDINATE EXACT THE CENTER OF THE FAN SPACING GOVERNS. SEPARATION DISTANCE IS 1-1/2" COND. DOWN TO 4" HUB DRAIN, SEE FOR WORK IN THIS AREA PLUMBING PLANS FOR SEE REMOTE TOILET HVAC CONTINUATION. PLAN ON SHEET M-2.1. J H G FLoa I I I I I I I I I I 1 4 c Ae 16 �C A7 Co -� - - L-7---- 2.5 1.1 C X7 I I I I I I I I I CO Co AC VL (TY12 I P.) AC 12 L - Lt OVERALL MECHANICAL PLAN SCALE: 1/32" = 1'-0" i REVIEWED FOR CODE COMPLIANCE APPROVED MAR 19 2021 City Of Tukwila BUILDING DIVISION 19-413 PM: JV CHECKED BY: PKR/ANT ISSUED: 04/17/20 OVERALL MECHANICAL PLAN ," mtq-onf� co a. m q ooc�z H � rnrnoa �+ a � � � z E aE . W E z a W ,.. ea: E� o�zo>i w w x¢ w E cm') E U1 CC P. Li. F $ m a I__I _J =e a r k®¢E 4 O � It X Oe Q Y o w o I FttVif=VlivD FOR CODE COMPLIANCE APPROVED MAR t S )021 City of Tukwila j BUILDING DIVISION r , N TEI #: 19-413 PM: JV 4£ CHECKED BY: PKR/ANT ISSUED: 04/17/20 ENLARGED HVAC PLANS M-2.1 NOTE: 1) ALL PVC ON EXTERIOR OF BUILDING To BE AC SCHEDULE 80. QQ ECONOMIZER DAMPER BLADE 4111' HOOD 2) PAINT ALL METAL & \1 WALL EXTERIOR TRANSITION FROM FULL SIZE OF UNIT PVC PIPING EXPOSED TO TO SLEEVE WEATHER- OPENINGS TO FULL SIZE OF DROP BOX INTAKE. PROVIDE FLEXIBLE WALL DAMPER FRAME INSTALL SUCH THAT BOX IS CENTERED CONNECTION FOR BETWEEN THE BAR JOIST AT ESFR SPRINKLER SUPPLY AND RETURN SUPPLY LINES. RETURN DROP (TYP.) SEE PLANS PROVIDE ROOF ROOF FLASHING (TYP.) ROOF CURB CONDENSATE ROOF BURGLAR BARS CONNECTION TO VENT PENETRATION DAMPER VENT VENT MOTOR ACTUATOR & BUG SCREEN CREEN COMBINATION AC RA/ TOP VIEW 26 ROOF PENETRATION COVER OPENING ENTIRE I OF SUPPLY AIk INSTALLED BY WITH 1r2"x12' DUCT SHALL BE INSULATED M.C. HARDWARECLOTH WITH 1-1f2" LINER. PROVIDE DECKTITE SIDE VIEW 0.139'WIFZE., PERIMETER x 0 FOR ROOF DOWN FROM MOUNTING FRAME 1$1 PENETRATION TERMINATE VENT FULL SIZE BE -LOW RETURN DLICT HORIZONTAL (TYP.) CONDENSATE OUTLET FROM AC UNIT BOLT TWO B-LINE B24 STRUTS SEE PLANS I-lj7MIN ON BOTTOM CHORD OF BAR FINISHED PENETRATERO RE JOIST. SUPPORT SUPPLY e-2q TWO BLADES EACH FLOOR AND RUN PIPE N TO DUCT FROM STRUTS. 20* OUT FROM SUPPLY UCT INTOTRUSS 1-112"RMN VERTICAL SPACE OUT FROM At INTERNALLY LINED 4-WAY AC LIN IT DIFFUSER PACKAGE. PROVIDE 2U'X l(Y'TUTTLE AC CONDENSATE PIPING DIAGRAM & BAILEY STRJ DRUM COMBINATION DAMPER DETAIL LOUVER AT 1,250 CFM. SCALE: N.T.S. 8 SCALE: N.T.S. [WIDUCT SMOKE DETECTOR [B]SUPPORT BOX WITH B-LINE FOR SYSTEMS 2,000 CFM THREADED ROD, AND ABOVE AND SERVING TURNBUCKLE AND J-HOOK AT MORE THAN ONE SPACE. EACH CORNER. PROVIDE 1/6' WW PROVIDED BY FIRE SAFETY CABLE AT EACH A PROTECTION CONTRACTOR BRACKET CONNECTED TO 0203=1 INSTALLED BY M.C. BAR JOIST. N.T.S. DIFFUSER DETAIL z. 'Ct NOTE INLINE TRANSFER TRANSFER FAN MAY BE SET UP PROVIDE SCREENED FAN FOREXHAUST OR SUPPLY OPENING ATFAN AIRFLOW. INLET O SIZE DUCT ORIENTATION WITH MATCH TRANSFER PLAN. CEILING STRUCTURE FAN WALL SLEEVE EXTERIOR WALL CONFIRM 0 TO L Lj L CEILING UNISTRU P1000 STRUCTURE (TYP.OF T-BAR WF GRAVITY CEILING BACKDRAFT DAMPER 24r24 GRILLE PER PLAN BIRD PROVIDE MASON INDUSTRIES AIR FLOW SCREEN #SLFH-B35 VIBRATION ISOLATOR BETWEEN UNIT AND UNISTRUT. (TYP. OF 4) REAR GUARD FIXED WALL LOUVER SIZED TO MATCH UNISTRUT FAN. Pl000 PERIMETER MOUNTING FRAME ANGLE FLOOR SUPPORT TOP VIEW SIDE VIEW SPRINKLER ROOM WALL EXHAUST FAN 47 s't TRANSFERS A 02DYM AC HZER \—# CONICAL SPIN -IN 10 ROOF ROOF CURB M VOLUME DAMPER SUPPLY DUCT PER DETAIL 3 (TYP.) ROOF FLEX AIR CONNECTOR SUPPLY x" RA DUCT SMOKE DETECTOR � SA FOR SYSTEMS 2,000 CFM AND ABOVE AND SERVING ZZ DUCT THAN ONE SPACE- PrROVLDED BY FIRE NYLON TIE -STRAPS SIZE PER PROTECTION CONTRACTOR PLAN INSTALLED BY M.C. LAY -IN CEILING DUCTS MUST RUN STRAIGHT DOWN DIFFUSER PERPENDICULAR TO FLOOR, FROM ROOF TO TOP OF STRUCTURE BE DUCTS TOBE INTERNALLY INSULATED -ED BY FOR RUN BETWEEN BUILDING ROOF LET D IY ND ANCILLARY FRAMING TER'NSCALE: N.DETAIL t I CE'LCEILINGLIGHTS TYPICAL ANCILLARY STRUCTURE (BREAK ROOM, OFFICE, TRAINING ROOM) MOUNTED N T �ED A �CU UNIT �TD DETAIL L BIRD SCREEN FAN BASE 1/3 FAN BASE MIN. CURB SEE SCHEDULE FOR PROVIDER GRAVITY BRCK DRAFTDAMPER. SIZE TO MATCH DUCT. 15 ROOF EXHAUST F FAN -- - - - - - - - - — FAN MOUNT SCALE: NTS O > NOTE: FAN BLADES NOT PERMITTED TO EXTEND SAFETY CABLE BELOW LIGHTING FIXTURE NOTE: (4)GUYWIRES INTERCONNECT FANS TO FIRE ALARM SYSTEM TO SHUT DOWN FAN PER NFPA 72 MOUNT — — — — — — — — — — — FAN PER MANUFACTURER'S INSTRUCTIONS HVLS FAN MINIMUM 30'TO NEAREST FAN AIR FOILS 36"MIN. SEPARATION DISTANCE BETWEEN FAN (SPEED CONTROLLER) SCALE: NTS 36'AFF INSTALLED HEIGHT BLADES AND EQUIPMENT LIGHTING FIXTURE NOTE: FAN BLADES NOT PERMITTED TO WALL KEYPAD CONTROLLER EXTEND BELOW LIGHTING FIXTURE INTEGRATE WITH BMS — — — — — — — — — STEEL PLATE OO FINISHED FLOOR ❑ LOCKABLENENTED ENCLOSURE, MOUNT 7 FEET ABOVE FINISHED FLOOR. SEE PLAN FOR LOCATIONS 4) *n�.��QUNTING DETAIL FAN, SEE SCHEDULE NOTE SECURE FAN TO CURB WITH #40 TEK SCREWS @ 17O.C. (MIN 2 PER SIDE) M.C. TO FABRICATE DROP -IN DAMPER TRAY AS REQUIRED. SIZE RIALTO MATCH DUCT. 8" MIN. pp