Loading...
HomeMy WebLinkAboutPermit M19-0183 - EIS INC - NEW RADIANT SPOT HEATER TO WORK STATIONEIS INC 18436 CASCADE AVE S SUITE 100 M19-0183 Parcel No: Address: City of TnnU°w^U Department ofCommunity Development 6]ODSouthcenuarBoulevard, Suite #10O Tukwila, Washington 981QQ Phone: 206-431'3670 Inspection Request Line: 2U6'438'9350 Web site: httm://ww/m'JuhwUam/A.gox 7888900030 Project Name-, EIS INC. MECHANICAL PERMIT Permit Number: M19-0183 Issue Date: 12/5/2019 Permit Expires On: 6/2/2020 Owner: Name; Contact Person-, Name: Address: Contractor: Name: LIT KENT VALLEY 1717K4CNNNEY4VSTE1900, DALLAS,WA, 75Z02 5108 S STREET NW, AUBURN, WA, 98001 EMERALD AIRE INC (CONSTRUCTION) Address: 5lO8DSTNW, AUBURN, WA, 980Ol' 24I8 License No: EMEK4410558L Lender: Name: Address: ''' Phone: (253)872'5666 Phone (253)872'5665 Expiration Date: 4/1/2021 DESCRIPTION OF WORK: NEW RADIANT SPOT HEATER TO WORK STATION WITHIN EXISTING WAREHOUSE. Valuation ofWork: $I162.00 Type ofWork: NEW Fuel type: GAS Fees Collected: $258.87 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKVV|LA Sewer District: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: ized Signature: National Electrical Code: WACities Electrical Codu VVA[296-408: VVAState Energy Code: OS 21 05 21 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tnsign and obtain this development permit and .8neetothe conditions attached tuthis permit. , PhntName/ This permit shall become null and void ifthe work bnot commenced within l8Odays for the date oyissuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will bedetermined bythe building inspector based nnsatisfactory completion ofthis requirement, 3: All plumbing and gas piping work shall beinspected and approved under aseparate permit issued by the City nfTukwila Building Department (28643l'3670)� 4: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. S: VALIDITY 0FPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation ofany of the provisions ofthe building code nrofany other ordinances nfthe City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. G: `MECHANICAL PERMIT O]NDDlON3*** 7: All mechanical work shall beinspected and approved under aseparate permit issued bythe City nfTukwila Permit Center (Z06/431'367O). 8: All permits, inspection record card and approved construction documents shall bekept atthe site ofwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. g: Manufacturers installation instructions shall heavailable onthe job site mthe time ofinspection. 11: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2016edidon). 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #Z437) 12: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ufsuch condition nrviolation. 13: These plans were reviewed byInspector 51l. |fyou have any questions, please call Tukwila Fire Prevention Bureau at(2O6)57S-44O7. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (20G)438'935O 1400 FIRE FINAL 0703 W1ECMEQUIP EFF 1800 MECHANICAL FINAL 0701 ROUGH|NK4ECHAm|CAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. '21-6 / Project No. Date Application Accepted: I — L.f7 Date Application Expires: q-2-o (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 7888900010 18436 Cascade Ave S, Tukwila, WA 98188 EIS Inc. Suite Number: N/A Floor: Warehouse PROPERTY OWNER Name: LIT Kent Valley Address: 1717 Mckinney Ave, Ste 1900 City: Dallas State: TX Zip: 75202 CONTACT PERSON — person receiving all project communication Name: Halie Schultz Address: 5108 D Street NW City: Auburn State: WA Zip: 98001 Phone: (253) 872-5665 Fax: (253) 872-5797 Email: permits@emeraldaire.com New Tenant: D Yes .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Emerald Aire, Inc. Address: 5108 D Street NW City: Auburn State: WA Zip: 98001 Phone: (253) 872-5665 Fax: (253) 872-5797 Contr Reg No.: EMERAAI055BL Exp Date: 04/01/2021 Tukwila Business License No.: 08_1151 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Add new radiant spot heater to work station within the existing warehouse, per plans. 3,162 Use: Residential: New D Replacement Commercial: New Replacement El Fuel Type: Electric ..... El Gas Other: HAApplicationsWorms-Apptications On Line12016 ApplicationsWechanical Permit Applicution Revised 1-4- 16.docx Revised: January 2016 611 Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater 1 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1.000,000 btu 30-50 hp/I ,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) IndustriaI 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDINr*NE! O1JT$OR1ZED AGENT: Signature. Date: 11/01/2019 Print Narne:�'ahte SchultzDay Telephone: (253) 872-5665 Mailing Address: 5108 D Street NW Auburn City WA 98001 State Zip HAApplicationsWorms-Applications Ott Line\2016 ApplicaliondtMechaitical Permit Applination Revised 1-4- 16.docx Revised: January 2016 bh Page 2 of 2 1 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY I PAID $258.87 M19-0183 Address: 18436 CASCADE AVE S 100 Apn: 7888900030 $258.87 Credit Card Fee $7.54 Credit Card Fee R000.369.908.00.00 0.00 $7.54 MECHANICAL $241.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $160.18 PLAN CHECK FEE R000.322.102.00.00 0.00 $48.33 TECHNOLOGY FEE $9.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18985 R000.322.900.04.00 0.00 $9.67 $258.87 Date Paid: Monday, November 04, 2019 Paid By: HALLIE SCHULTZ Pay Method: CREDIT CARD 850560 Printed: Monday, November 04, 2019 11:34 AM 1 of 1 SYSTEMS 0 CO TVxwzLx s7nAKIT 0200 S0UTMCENTER BLvo TUxWILx, WA e8188 206-433'1870 [zTv OF TUKWILA 0017340800802374464500 Date: 11/04/2019 11:33:42 AM VISA CARD NUMBER: TRAN AMOUNT: APPROVAL [D: RECORD #: CLERK ID: X CREDIT CARD SALE **********1594 x $258.87 850560 000 frankic {CARDHOLDER'S SIGmAruns} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: NIC Type of Ins e ion: Address a 3 ... Date Called: Special Instructions: Jet 11(C 0 cJ "Date Wanted: Requester: ,.Y---- Phone No: 24)14, IJ..."7*gr. Approved per applicable codes. Corrections required prior to approval. 1 COMMENTS: Inspecto Da REINSPECTI FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT -NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project , r-Are...417 'T of $ pect(on: Address: JS%3c r � s, Date Called: ...M.._ Special Instructions: d a4*±.00 Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. rrections required prior to approval. COMMENTS: -Sir IC_ Date: 7- REINSPECTI©N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cat[ to schedule reinspection. EIS Facility • Tukwila LREV IEWED FOR OR ODE COMPLIAN APPROVED DEN 20 GENERAL INFORMATION PROPERTYTAX NO.: Ta88900010 LEGAL DESCRIPTION: PROJECTLOCATION: 18404 Cascade Ave So. • Tukwila, 98188 PROJECT DESCRIPTION: Add natural gas radiant spot healer, warehouse work area I station. VAC CONTRACTOR: EMERALD AIR[ INC 5108 D STREET AUBURN, W4 98001 PROJECT MANAGER: CONTACT, EMERALD AIRE, INC. VOICE: (2531 872.56(5 FAX, (253) 872-5797 ERAL CONTRACT NIA INDEX: I. SHEET) SITE FLANVI It No. �tl t� 111I, Pla review appro al Is suoiea to errors omen s. Approval of construction aocuments does 102 au orize the v1o!at1en of any adopted cone or artlin rM a Receipt of aporovee Fiala Copy and Coy al TUNA4IIa Burr DING DIVISION Existing 200k unit heater, freeze POC `1" GENERAL MECHANICAL: STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ART, ASNE, ASTM, LL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY DES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CEDES AND ORDINANCES, IN CASE OF CONFLICT BETWEEN THE ORAWIN 11/112 CIFICA113NS AND THE CODES AND ORDINANCES, TIE MOST STRICT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY, THE MECHANICAL CONTRACTOR SIO.L SATISFY CODE REQUIREMENTS B REQUIREMENTS OF THE CONTRACT 800uMENIS AS 4 MINIMUM STANDARD, APPLICABLE C 2015 I BUILDING CODE 2015 SE LE MECHANICAL LODE 20 1 E ENERGY CODE DRAM TO PROVIDE ACCESS 10 FIRE NAOIIR IICN FIRE/SMkGAi�R 6i0 SEPARATE REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISION VICINITY MAP: 01 TO SCALE arehouse height floor to ceiling I roof at 28' Work area I station New 90k Btu's spot he a r w/ mooting No r' - :C> s1 ar , . i,IP to Incscone heiA ht at �' 16' W 18' Of worn w1In0/7 0: the Tukwila Building 2Ivls!on NOTE: Revisions will require a new plan Ital and may Include additional plan review, in r 30' —GAS—GAS — GAS — GAS _ GAS — GAS — GAS—GAS--GAS—GAS— Warehouse Floor Plan NTS ENERGY CODE & COMMISSIONING NOTES: IHER9S14TS SHALL 8E INIERIOCNEO TO PREVENT SIMULIAIECUS HEATING AND COOLING DOERS Stall N18JLA1E OUTSIDE AIR FROM !GIGO TO)COO ECO012ER COSIRIS SHALL BE CAPABLE OF EVALUATING OUTOR AIR 019011 6 CAPACITY INSUATE REFRIGERANT PIPING SEAL DUCTWORK INSULATE DU[1VORN COMMISSI1NIN6 PER SEC INCLUOIMG alMISSIONING PLAN, SISTERS BAL9821 C, FUNCTIONAL TESTING, CONTROLS TING, IPERAIIEN AND MAINTENANCE MANUALS, AND RECORD DRAWINGS, SHALL BE UNIFIED 10 OWNER ON PROJECT CIMPLETI1N, INSTALL ALL T9RM1SIAIS AT A8' AFF ENVIRONNI[N1AL AIR 10 MAINIO;N 1' FROM OPERABLE OPENINGS, IT FROM EC (CAL INTAKES NVAC LEGEND 8 ABB ITISttihita D DENTF BUILDING DI ' 1 1 BIDE BALL ER LL SUPI7 GRILLE 1 IH[RMATUS[R ® REIVII AIR GRILLE 0 [11191SI GRILLE a EX9US1 FM [2IIPMEN11AG O 1-5141 CD/NO, SENSOR OCCUPANCY SENSOR L/V WIRE O 0.LT KIN r ELB12 0➢ MCP L SIDE TAPS 90 [LB[W - A N/ ID3'ING WANES NMN NP FLEXIBLE CUCI - Es MANUAL BAMPER FIRE DAMPER SHOE DAC r7 SMOE/FIF9 BANTER MO7ORI1[D OANP[R W BACKDRA6I 34P R VARIABLE '11LNE/TEMF[RA110E AP NEAT NAP HP mCRSEP0919 N,C XEAING Kra Xu1D1 IC IN9CE DRAFTER N0E5 RN NOWT LAT IEANRC AIR IEia99AARRE 185, ATMS LC &ANAL WN1CM TENPENANRE OA RCAF NA) NON w3X INCUSAR0 BMS RR AGAR MN LPWIWN NS N010, STARTER NC 99189E 0N1ERA Nis NOI N SCALE OA bJr9CE AR OBO 5PP095 WOE OAN6ER CC ON 09NR CC 0.PS0E OIANEIER PR PNAEE P9 POJNO0 PER 101AR[ NCR an CA1AN15 AKA RENaO mg PFP R7005AN1 REr PIRA RN ARAM 9 911911 RN RNO PARKA RW RE<t101CNS PER MNOIE SA MALT Ale MOOR ENERGY E111ENCr RA1N0 SERNI HEAT SAW' Oft 9RA9 STANC PRESSURE 1OPERANPI of UNOERa1T CAR VOLT OK VAp18EE NR WI v9UNE 0411E (MAN; °PERAOOR) "" RECEIVED :';'..CITY OF TUKWI 91Xa1 042019 PERMIT CENTER 900 OArt 1111 DR SERIES HIGH INTENSITY SUBMITTAL DATA GAS -FIRED INFRARED SPACE HEATERS SUBMITTED BY: Emerald Aire, Inc. JOB TITLE: ADDRESS: 5108 D Street NW CITY: Auburn STATE: WA ENGINEER: Ron Fisher ZIP: 98001 DATE: 10/31/19 CONTRACTOR: Emerald Aire, Inc PHONE #: 253-872-5665 A S A REVIEWED ..OR A-rECPWCOMPLIAN VED ZIP: Same LOCAL REPRESENTATIVE: Dorse Company NOTES: QTY. DEC 02 2019 INPUT BTU/h (Indicate Gas TQe) 0 CERAMIC SQ. IN. of NATURAL PRO NE OPERATING RADIATING MODEL # TAG GAS GAS TEMP. SURFACE DR 30 DR 30(S) DR 45 DR 50 DR 55 DR 60 DR 75 DR 80 DR 85 DR 90 DR 95 DR 100 30,000 30,000 1780° F City of Tukwila BUILDING DIVISION MOUNTING HEIGHTS (Standard NET Reflector) WEIGHT 85 12' to 14' 18 lbs. 30,000 30,000 1780° F 85 12' to 1418 lbs. 45,000 45,000 1660° F 170 12' to 14' 50,000 50,000 1690° F 170 12' to 14' 55,000 55,000 1740° F 170 13' to 15' 60,000 60,000 1780° F 170 14' to 16' 75,000 75,000 1690° F 255 15' to 17' 80,000 80,000 1720° F 255 15' to 17' 85,000 85,000 1750° F 255 16' to 18' 90,000 90,000 1780° F 255 16' to 18' 95,000 N/A 1800° F 255 17' to 20' 100,000 N/A 1810° F 255 17' to 20' 27 lbs. 27Ibs 27 lbs. 27 lbs. 36 lbs. 36 lbs. 36 lbs. 36 lbs. 36 lbs. 36 lbs. DR 130 130,000 120,000 1810° F 340 21' to 24' 45 lbs. DR 160 160,000 145,000 1810° F 425 24' to 28' 54 lbs. CONTROL VOLTAGE (See Page 2) 120V 24V Millivolt • RECEIVED CITY OF TUKWILA NOV 0 4 2019 PERMIT CENTER DETROIT RADIANT PRODUCTS CO. VISIT OUR WEBSITE FOR: RE-VERBER-RAY by Detroit Radiant Products Company 48ED DADIA 21400 Hoover Rd. Warren, MI 48089-3162 Phone: (586) 756-0950 Toll Free: (800) 222-1100 Fax: (586) 756-2626 Email: sales@drp-co.com Website: www.cletroitradiant.com Product Specs Ports Support Dealer Locator Applications CAD/Revit Library Design Guidelines Theory of Infrared and More! LSDR-5c-1218(CDS) A WARNING Read and understand the installation, operating, and maintenance instructions thoroughly before installing or servicing this equiptment. Only trained, qualified gas installation and service personnel may install or service this equiptment. This heater is NOT for home or recreational use. DO NOT USE in the home, living quarters, attached garages, mobile homes, RVs, campers, tents, etc. NOMINAL MANIFOLD PRESSURE Natural Gas - 6.0 in. W.C. Propane Gas - 10.0 in. W.C. MINIMUM HEATER INLET PRESSURE Natural Gas - 7.0 in. W.C. Propane Gas - 11.0 in. W.C. MAXIMUM INLET PRESSURE 1/2 Ib. or 14.0 in, W.C. VA DRAW 24V - 12.0 120V - 12.0 MOUNTING ovic,59 20° to 35° from horizontal. Optional - Horizontal parabolic reflector (specify size) to emulate 0-15° angle. INLET PIPE SIZE 1/2" NPT MOUNTING HOLE DIAMETER 5/16" AMP DRAW 24V - 0.48 120V - 0.10 CONTROL CONTROL Nat. Prop. VOLTAGE CONTROL DESCRIPTION NMV-2 PMV-2 Millivolt NFS-2 PFS-2 120V or 25V Manual Ignition, Constant Pilot, 100% Shutoff, Self -energizing wire & thermostat. Direct Spark Ignition, 100% Shutoff, All spark models include potted circuitry for use in high moisture applications. CLEARANCES TO COMBUSTIBLES (IN INCHES) MODEL NO. DR 30 DR 30(S) DR 45 DR 50 DR 55 DR 60 DR 75 DR 80 DR 85 DR 90 DR 95 DR 100 DR 130 DR 160 SIDES BACK TOP 30 30 30 30 32 32 48 48 48 48 48 48 48 18 18 18 18 18 18 30 30 30 30 30 30 30 50 32 BELOW/ FRONT 28 72 28 72 28 72 34 72 40 721 40 72' 42 98 42 98 42 98 42 98 52 120 52 120 52 120 60 132 Clearance is 80 in. when heater is fitted with a parabolic reflector. NOTE: If the heater is mounted beneath a non-cambusfible surface, a 24 in. minimum top clearance must be maintained from the top of the heater to prevent overheating the controls WARNING Read and understand the installation, operating, and maintenance instructions thoroughly before installing or servicing this equiptment. Only trained, qualified gas installation and service personnel may install or service this equiptment. This heater is NOT for home or recreational use. DO NOT USE in the home, living quarters, attached garages, mobile homes, RVs, campers, tents, etc. TOP (cel ing) • BACK Manifold/ Canto, End SIDE MOUNT HEATER LEVEL SIDE TO SIDE SIDE A\ WARNING Failure to comply with the stated clearances to combustibles could result in personal injury, death, and/or property damage. If vehicles are parked below the heater or lifts are present, ensure that all clearances will be maintained from the highest raised vehicle. FIELD DATA DIMENSIONAL INFORMATION DIM. "C" 11011111111111 1 1 1 1 II1 CO DIM. "A" FRONT/REAR MODEL NO. DR 30 DR 30 (S) DR 45, 50, 55, 60 DR 75, 80, 85, 90, 95, 100 DR 130 DR 160 HEATER WIDTH DIM "A" 12 3/4" 12 3/4" 19 1/8" 26 5/8" 32" 38 1/2" A cm HEATER DEPTH DIM "B" 151/4" 151/4" 151/4" 151/4" 151/4" 151/4" DIM. "B" SIDE VIEW CENTER OF MTG. HOLES & RAYHEAD WIDTH DIM "C" 51/8" 18" 21" 27 1/2'' OPTIONAL ACCESSORIES QTY. PART NO. DESCRIPTION DRCS Chain mounting set DR#HPR Horizontal parabolic reflector DR#PR Full parabolic reflector Full parabolic reflector with DR#PRSC screen DR#SC DR heater screen PLQ Warning plaque # = Specify Number : 1 = DR 30; 2 = DR 45-60; 3 = DR NOTES 5' chain set with 4 "S" hooks. Preset mounting angle of 30°. Directs rays directly downward. Can be used for matching horizontal mounting specifications. Directs rays in a more focused pattern. Typically used in high mounting applications. Directs rays in a more focused pattern. Outer screen protects ceramic grids from objects striking the heater. Screen slips on the outside of the reflectors and protects the ceramic grids. Hung below heater, restates the clearance to combustible warning. 75-100; 4 = DR 130; 5 = DR 160 WRITTEN SPECIFICATIONS ^ - HEATER ' High Intensity Infrared Heaters shall be 8e'Verber- RoyO DNSERIES, osmanufactured byDetroit Radiant Products Company, Warren, MI 48089. High Intensity Infrared Heaters shall beDesigned Certified byCSA. The manufacturer shall provide opublished warranty covering the heater's ceramic burner for operiod offive (6)years and all components utilized inthe heater control assembly for operiod ofone (l)year. High Intensity Infrared Heaters shall be designed to operate when burning natural gas having oheat value of 1025 BTU per cubic foot with o specific gravity ofU.62'orwhen burning propane gas having oheat value of25O0BTU per cubic foot with o specific gravity of 1.53. The ceramic burner face shall operate oto temperature range of 1660degn*es Fto 1810dognees Fand shall incorporate asecondary re'rodia1ing surface ofstainless steel rods toobtain optimum operating temperature and radiant output. The manufacturer shall have ominimum of3Oyears of manufacturing experience producing high intensity infrared heaters. TYPICAL WIRING DIAGRAMS ^-- Thermostat DR Series DR Series Heater .,.A, Heater |�T�' � ��Y��N ����INFRARED ���E BURNER CONTROLS Heaters shall boequipped with one ofthe following control systems: Standing Manual Pilot System with 100% safety shut-off of pilot and main burner in case of pilot outage, operating with noexternal electrical connection but onmilli-voltage generated bythe pilot flame (N&4\-2orPKA\-2). X Direct Spark Ignition System with direct spark ignition ofthe main burner through m solid state ignition module operating ospark electrode. Loss of power causes l00%sofety shut-off of main burner(d. System operates on l2Oor24volts (NF3'2orPFS'2). HIGH INFRAREWHEATER CONSTRUCTION � The heater reflector housing shall boconstructed cf one -side bright polished aluminum. The emitter shall be composed of a perforated ceramic tile onwhich combustion takes place onthe surface. The burner plenum shall be constructed ofaluminized steel of one-piece drawn construction. The heater shall be of modular design employing multiple burners to achieve the specified input. The venturi is constructed of stainless or aluminized steel. The secondary re -radiating rods shall be constructed mfhigh temperature stainless steel alloy placed in dose proximity ofthe ceramic burner face. Parabolic reflectors shall beused when units are installed inhigh mounting applications o/when focusing ofthe infrared hooting pattern is desirable. Protective screens shall be used in facilities where debris may damage the heater. DR Series Heater Exhaust Fan Hot NOTE: Local codes may require that an exhauster is interlocked with the thermostat. •q)ERM!T COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0183 PROJECT NAME: EIS INC. SITE ADDRESS: 18436 CASCADE AVE S 100 X Original Plan Submittal Response to Correction Letter # DATE: 1 /04/2019 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works IttlAt Fire Preve ion um Structural n Planning Division Permit Coordinator Ell • PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/05/19 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) DUE DATE: 12/03/2019 Approved with Conditions E Denied (ie: Zoning Issues T Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire El Ping LJ PW 0 Staff Initials: 12/18/2013 0 Some online services are currently unavailable. See a list of service outages. (https://lni. &ten / stem-st tu I Labor & Industries (https://hti.wa,govl Contractors EMERALD AIRE INC Owner or tradesperson Principals HAPPE, DAVID DUSTIN, PRESIDENT MIDDLETON, GRANT JAMES, PRESIDENT RIDGE, JOHN PATRICK, VICE PRESIDENT HAPPE, DOUGLAS A, PRESIDENT (End: 03/25/2019) RICHARDS, RON, SECRETARY (End: 06/01/2000) DUPUIS-FRICKE, LINDA, PRESIDENT (End: 12/31/1999) HAPPE, DOUGLAS A, PRESIDENT (End: 12/31/1999) TREMAINE, DAVIS WRIGHT, AGENT (End: 12/31/1999) Doing business as EMERALD AIRE INC WA UBI No. 600 591 552 5108 D STREET NW AUBURN, WA 98001 253-872-5665 KING County Business type Corporation Governing persons DOUG HAPPE JOHN RIDGE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. EMERAAI055BL Effective — expiration 01/13/1995-04/01/2021 Bond Merchants Bonding Co (Mutual) Bond account no. WA100080 Received by L&I 12/29/2016 Bond history $12,000.00 Effective date 01/01/2017 Expiration date Until Canceled Insurance Depositors Ins Co $1,000,000.00