HomeMy WebLinkAboutPermit M19-0190 - STERLING SOUTHCENTER - INSTALL (1) AESTHETIC ONLY NEW FIREPLACE IN THE LOBBY AREA ON THE 1ST FLOOR, INCLUDING VENTING ANDSTERLING SOUTHCENTER 411 BAKER BLVD BLDG M19-0190 �~^�«x m�� Tukwila "��^ v�o " ��nx���o�� ^ � ~o Department 6�OO�ou�hcen�erBnu|exa Tukwila VVashin��ongg%O c�^ nhone'zoa��t'ss7u Parcel No: tof t 6�OO�ou�hcen�erBnu|examd,Suho#1VO Tukwi|a,VVashin��ongg�OO �hnne�JOG43z,367U Inspection Request Line: 206-438'93S0 Web site: htto://www.TukwilaWA.Rov MECHANICAL PERMIT 0223100080 Permit Number: M19-0190 Issue Date: 12/3/2019 Permit Expires On: 5/31/2020 Project Name: STERLING SOUTHCENTER Address: Contact Person: Contractor: Name: License No: Lender: CRP/AR TUKVV|LAOWNER LL[ 2525E[AMELDA[KRD#500' PHOENIX, WA, 85016 VV|LLNK4 N1|LiH0LUN FIRESIDE HOME SOLUTIONS I83&95VVBOONE6FERRY RD. PORTU\ND,OR, 972Z4 F|RpSMS879RU ''' Phone (503) 684- 535 Expiration Date: 1/14/2020 DESCRIPTION OF WORK: INSTALL (1) AESTHETIC ONLY NEW FIREPLACE IN THE LOBBY AREA ON THE IST FLOOR, INCLUDING VENTING AND DUCTWORK. (NO NEW HEATING CAPACITY) PREVIOUSLY PERN1nTEDUNDER Ml8'D095. ASSOCIATED WITH CONSTRUCTION Dl7'O]0B. Valuation of Work: $35,766.00 Type of Work: NEW Fuel type: GAS Fees Collected: $67721 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: international Mechanical Code Edition: Uniform Plumbing Code Edition: international Fuel Gas Code: 2015 20152015 2015 2015 National Electrical Code: VVACities Electrical Code: vVAC2964613: VVAState Energy Code: 2017 2017 2017 ZOlS Permit Center Authorized Signatu Date: |hearbycertify that | have read ak-m4aminedthis permit and know the same tohetrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state nrlocal laws regulating construction orthe performance ofwork. |omauthorized tosign and obtain this development permit and agree tothe conditions attached tothis permit. Signature: - '- '- Print Name: 6��/ �~ �/Uy\/V�//*� , _ °�__� , , ` Date: /Z _ 3 This permit shall become null and void if the work isnot commenced within l8Odays for the date ofissuance, orif the work is suspended orabandoned for aperiod uf18Udays from the fast inspection. PERMIT CONDITIONS: 1: Work shall beinstalled inaccordance withtheopprovedcunstrvcdon4ocuments,andpnychangesmade during construction thatarenutinaccordanoewiththeapprovedoonstruoLiondocumentsshaUbe resubmitted for approval. Z: All permits, inspection record card and approved construction documents shall bekept atthe site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. ' 3: All construction shall be done inconformance with the Washington State Building Code and the Washington State Energy Code, 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (2O643l'3G7O). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. G: VALIDITY DFPERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances nfthe City nfTukwila shall not bpvalid, The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction oferrors in the construction documents and other data. 7: `MECHANICAL PERMIT ODND000N5*~~ 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/43l'3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection, lU: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2oV)438'935V 1800 MECHANICAL FINAL 0701 ROUGH'|NKxE[HAN|[AL Tenant Name: CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M 19 /CIO Project No. Date Application Accepted: / I 2-0 ( Date Application Expires: S —2.. 0 2-0 or Ice use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 0223100080 King Co Assessor's Tax No.: Site Address: 415 Baker Blvd Suite Number: Floor: New Tenant: IJ Yes 1]..No STERLING SOUTHCENTER PROPERTY OWNER Name: BAKER BOULEVARD ASSOCIATES Address: 415 BAKER ST City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: WILLIAM MILLHOLLIN Address: 9808 31st Ave SE City: Everett State: WA Zip: 98208 Phone: (206) 601-7043 Fax: Email: william@nwpermit.com MECHANICAL CONTRACTOR INFORMATION Company Name: Fireside Home Solutions Address: 21402 84th Ave S City: KENT State: WA Zip: 98032 Phone: Fax: (360) 945-2787 Contr Reg No.: FIRESHS879RU Exp Date: 01/14/2020 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 35,766 Describe the scope of work in detail: Install 1 aesthetic only new fireplace in the Lobby area on the 1st floor, including venting and ductwork. (No new heating capacity) Previously permitted under M18-0095. Associated with construction #D17-0300 Use: Residential: New 0 Replacement El Commercial: New Replacement El Fuel Type: Electric E] Gas Other: ApplicationsWorms-Applications On Line \ 2016 ApplicationsNechanical Permit Application Revised 1-4-16.docz Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfrn Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove 1 Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; - Construction and property maintenance during the daytime hours (7am-l0pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR UTHORIZED AGENT: Signature: Print Name: William Millhollin Mailing Address: 1026 SW 151st ST Date: 11/20/2019 Day Telephone: (206) 601-7043 Burien WA 98166 City State Zip H:\Appliications\Forms-Applications On Revised: January 2016 hh 016 Applications Mechanical Permit Application Revised 1-4-16-docx Page 2 of 2 DESCRIPTIONS 1 ACCOUNT QUANTITY PAID PermitTRAK $677.21 M19-0190 Address: 415 BAKER BLVD BLDG Apn: 0223100080 $677.21 MECHANICAL $651.16 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $487.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $130.23 TECHNOLOGY FEE $26.05 TECHNOLOGY FEE TOTAL.FEES PAID BY RECEIPT: R19125 R000.322.900.04.00 0.00 $26.05 $677.21 Date Paid: Wednesday, November 20, 2019 Paid By: NORTHWEST PERMIT, INC Pay Method: CHECK 5003 Printarl• Warinecrlav Nnvemher 7n_ 7m1337 PM 1 of 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr e t: . ,-- Type n ect on: 11 Ad re E. vds Date a ed: Special n tic ons: Date Wanted: f, a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd_ Suite 100. Call to schedule reinspection. PERM!T MORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0190 DATE: 11/21/2019 PROJECT NAME: STERLING SOUTHCENTER SITE ADDRESS: 415 BAKER BLVD BLDG X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Avo h Building Division Public Works km \\\Viiel Fire Prevention Planning Division Structural 1 1 Permit Coordinator n u PRELIMINARY REVIEW: Not Applicable (no approval/review required) DAIb: 11/26/19 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required LJ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/24/2019 Notation: REVIEWER'S N T S: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire El Ping 0 PW 0 Staff Initials: 12/18/2013 CWe:hippo St.r- De,reenrcr:i re 41 tabor & industries (https;HIni.wa.gov) o Contractors FIRESIDE HOME SOLUTIONS Owner or tradesperson Principals WATERSTRAAT, JOHN MITSUOKA, PARTNER/MEMBER WIDDOWS, THOMAS ABE, MANAGER (End: 01/11/2018) Doing business as FIRESIDE HOME SOLUTIONS WA UBI No. 603 198 045 Parent company FIRESIDE CONTRACTING SRVCS LLC ILicense 18389 SW BOONES FERRY RD PORTLAND, OR 97224 503-684-8535 Business type Limited Liability Company Governing persons PACIFIC COAST JOHN MITSUOKA WATERSTRAAT; THOMAS A WIDDOWS; INC FIRESIDE OF OREGON; INC FIRESIDE OF WASHINGT; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. FIRESHS879RU Effective — expiration 01/14/2014— 01/14/2020 Bond RLI Ins Co Bond account no. LSM0782709 $12,000.00 Received by L&I Effective date 01/22/2016 01/22/2016 Expiration date Until Canceled Bond history Insurance American Fire & Casualty Co $1,000,000.00 Policy no. BKA56692518 Received by L&I Effective date 05/28/2019 06/01/2018 Expiration date 06/01/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings ❑• m m X ME m m • 2® v v LOUVER AT HIGH \LEVIE1 LOUVER AT12' AFF 14'x8' OUTDOOR AIR DOWN TO LOW LEVEL IN \ 14"x8" EXHAUST ABOVE 0/N 1 �6 \ 14"x8' OUTDOOR AIR \ \ IS-, --� \ R7 TH AL INSULATION— 1 "" \ ON OUNAIR DUCT. 1100 ENCLOSED PARKING GARAGE VENTILATION- \ HRV D SECONDARY PARKING 100B: 3.181 S.F. 0 0.75 CFM PER SF \ 1 \ = 2,400 CFM \\ 30' HIGH \ \ PROVIDE (1) 2,500 CFM GARAGE TRANSFER FAN. VFD FOR GARAGE ANSFER FAN \ - - - - - - _ \ I"-T--i ------I W�1-8 MOUNTED TO T— � `--f --� Gl`w jig \ r 1_6 7 t i \ \ \ END SWITCH ON CO/NO21-1 _ GTF \ WIRED TO GTF-1-2. Q ` 1-2 \ I I I I I I I I I I I ELECTRICAL CONTRACTOR SHALL SUPPL DIESEL FUEL FIRED EMERGENCY GENERA SUBBASE FUEL TANK, MUFFLER, AND REMOTE FUEL FILL STATION. IN ACCORD WITH GENERATOR'S INSTRUCTIONS, MECHANICAL CONTRACTOR SHALL INSTA DUCTING FROM RADIATOR TO EXHAUST LOUVER, DUCTING FROM AIR INTAKE LO TO ROOM FOR COMBUSTION AIR, ENGINE O EXHAUST PIPE FROM MUFFLER TO DISCHARGE POINT, SUBBASE FUEL EL TANK VENTS TO EXTERIOR WALL (MINIMUM 5'- FROM BUILDING OPENINGS), AND PIPING FROM FUEL FILL STATION TO SUBBASE TANK. 0 L-1 165_x24" 0 0 6"0 ENGINE EXHAUST (WITH 2' CALCIUt SIUCATE INSULATION) 3"0 SUBBASE TANK EMERGENCY VENT 2'0 SUBBASE TANK NORMAL VENT 3"0 SUBBASE TANK EMERGENCY VENT 2'0 FUEL FILL FROM FUEL FILL STATIO TO SUBBASE FUEL TANK. END SWITCH ON GO/NO21-3---- WIRED TO GTF-1-1, 0 0 0 0 0 0 0 0 0 //l�STEMICES RVED BY A DEDICATED OUTDOOR AIR S.2 BAKER BLVD Y(DOAS): HEAT RECOVERY VENTILATOR HRV-1. 8 0 200 ■ 10"0 B-VENT 14"x8' COMBUSTION AIR 8'0 COMBUSTION AIR g24*x1e8* 6"0R-1 80 8"x8" VENTING OF FIREPLACE BY OTHERS UNDER 1 _ M1.1 SEPARATE MECHANICAL PERMIT. FIREPLACE SECTION SCALE: 118" = 1'-O" 0 0 6'0 i i 0 B-VENT 250 6'0 8'0 8'0 10'0 B-VENT ABOVE L_1 6 0 0 8"0 8"0 COMBUSTION AIR I 39'x12' 10'0 B-VENT 6"0 N1RED TO FC-3. -- ---JJ eo EXHAUST AND MAKE-UP AIR DUCTS FOR FUTURE KITCHEN. HORIZONTAL DUCTING ON OTHERS GTF O ��� �� 0\x24' NFPA 966 KITCHEN EXHAUST DUCT q{p j 1-3 \ DG-1 10'x6' 18"x10" FA WITH FIRE RATED DUCT WRAP AND 2 i ACCESS PANEL ON EACH FLOOR. ipp 20'X24" MAKE-UP AIR DUCT FA. f-----1 i \ i 12 "z1 ' 44'xl4" FA. \ \ I R7 THERMAL INSULATION OR OUTDOOR AIR DUCT. 26'xl ' Sl L-1 20"AY RA TA / 24N24" \ ;GTF 20'xl6" SA FA - \ \ , 0 20'z20' RA TA 1-4 \ \ \ 12-07 FC \\rJ,• \ / T x 2 SEND SWITCH ON CO/NO21-2/ I \ \T \ HIRED TO GTF-1-3 8 4. Ir R-1 R-1 FUTURE KITCHEN HOODS o c 24'x24' 8^® 24x24" OTHERS INCLUDING DUCT$ TO \\\ \\ EDH VERTICAL RI BEHINN 1-1 THERMOSTAT N1TH CO2FOR DEMAND CONTROL \ \ / 1-1 VENTILATION. OUTDOOR AIR DAMPER SHALL BE O \ \ \ VFDs FOR GARAGE EQ)IENAUST OHP 1-1 OPENED IN RESPONSE TO CO2 LEVEL \\\\ \\\FANSMOUNTEDFV2-1 TOyY ON2WALL e -� IHBPWSEC2CC ANT OAD I .6. SPACE IS E 500 SF AND OCCUPANT LOAD IS > 25 PEOPLE PER 1,000 S.F. / S t 60 \ \ \\ OHP a c \ \ «+r 7 7 18' � 267 8'0 ® _ _ 8"0 m S-2 20 , _ 10"0 g"0 fVFD1 8"0 Uj i-2 ® IHP 0 9 E-1 I t� \ \ 18"x18' LU TO LEVEL 2 EL 2 TO TRANSFER \ 650 TO LE VENTILATE GARAGE \ LEVEL 1. Q 6'0 \ pp 4'-0"x4'-O" TRANSFER FED TO LEVEL 2 TO VENTILATE GARAGE 1-1 1E2 • 10" .,.F, r..... ,13^ LEVEL 1. \ \ Vo "FLFORDOZ \ LL BE MINIMUM 3'-0" OPERABLE OPENINGS. 10 END G \\❑❑� \ \,.,� 5 WIRED CTTCH f Ni C5 /N021-5 /No 1-5 VA 1 /NO 1-4 I 1 GO SENSOR 05'-0" AFF I 1 NO2 SENSOR 0 l'-6" AFF rp ARK MECHANICAL PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 END OF LINE FOR — —' CONTROLS CIRCUIT 1'4 � • I I I 1 1 .. .....__._..___..__.,. FIL'_E L' ��(� AennitNo 'Q` amp slronspAPpro va of Lo; ,�'uC em 0c1.ne , . E END SNITCH ON CO/N021-4 t / %RED TO GTF-1-7. GTF j �(/ 1-7 v - 7 S 1 1100 " —I 1 I 11 i. CONTROLSCONDUIT NCONTRACTOR. OVE BY WIRING IN CONDUIT BY I I CONTROLS CONTRACTOR. 1 i� 3ar aotnonze ine vioiatior of err "o" xninence RCOPa1:0 S SAU�r.we,,((� Voo�r: By — bate. 7-,.�-- 3uiLooa,:. ;, _, r; REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR FSD 6"x10' FA I 1 I 1 ENCLOSED PARKING ARAGE VENTILATION, MECH. PERMIT 05/24/2018 REVIEW } i FD0® } J I 1 I 1 I 1 I 1 LEVEL 1: PROVIDE GEF-1-1 23,126 S.F. 0 0.75 CFM PER SF = 17,350 CFM (3) 6,000 CFM GARAGE EXHAUST FANS TO GEF-1-3 FOR A TOTAL OF 18,000 CFM. TRASH/RECYCLE IS VENTILATED 111 BY TRASH CHUTE FAN EF-R-1. 2'0 FUEL FILL (2) 24"x24" METAL MESH 1 I I 1 FROM FUEL FILL TRANSFER GRILLES 0 LOW STATION TO LEVEL SUBBASE FUEL TANK. 1 I I I I 1 1'0 CONDUIT TA I 1 1 I O REVIEWED FOR END SWITCH ON CO/NO21-5 CODE COMPLIANCE WIRED TO GTF-1-6. APPROVED I b DDC CONTROL PANEL. ,1 DEC OP 2019 I / 20 AMP, 120/1/60 CIRCUIT BY iV J (f q ELECTRICAL CONTRACTOR. f1 (C f) IL 1 -- City of Tukwila k BUILDING DIVISION JUNCTION BOX IN SLAB. TYPICAL - �"--" M19-60190 2 -L FILL STATION (SU�"750 kVA TRANSFORMER. NATURAL VENTILATION ELECTRICAL CONTRACTOR). SHALL BE 3 SQUARE INCHES PER kVA. IIMUM 5'-0" FROM BUILDING MINIMUM 15.6 SQUARE FEET. ENINGS. 20 SQUARE FEET PROVIDED. O RECEIVED CITY OF TUKWIL NOV 2 0 2019 PERMIT CENTER DRAWING TITLE LEVEL 1 MECHANICAL DATE MAY 2018 DRAWN BY DL SCALE A"=1'-0" mi .1 \ \ O \ O \ O O \ u m m m m EN U `- m m ------- ------------- -------- -------------------—---------- — --_` N I \ 0 4' 8' 1s' I IHP FC \ }2 .ate-► � g \ I j t S-1 30 R-1 \ 12"x6" 24'x18' /y 200 S-1 20 EF-2 , 1 1 # \ 14• ET 2 !S • 400 \ 8°f 8'f Wo M EF-i 16'x8' 10'f \ EF-1 24"x10' .� e / FC x .. , 5 U T FD E-1 S-1 R-1 40 1 10'0 FLUE FB . I 1" 1 " 36'z14' 2"x614'x14" FIREPLACE ITPOWER O _ 2� - 24•XIxt8• VENTER BY OTHERS. RS. I EXHAUST AA?Np MAKE-UP AIR DUCTS FOR FUTURE KITLNN. HORIZONTAL DUCTING ON FD J_________________________________ LEVEL I BY OTHERS. I 20'x14" 20'xl4' 20"x2C NFP 9FA NTH A6 KITCHEN'DUCT EXHAUST DUCT FIR HOT NB BOILER \-------------------------------------------- 1 B'0 ACCESS PAN EACH FLOOR. WRAP AND BY OTHERS 350CFH \ HP +� 20'X2e MANE -UP AIR DUCT FA. FD OHP G1F OHP e I I FC I 2 3\ 1 6 i6'x20' FA I 4 T 20'x13• RA FB L-t L-1 \ FIRE RATED I 20'x16" SA \ B ENCLOSURE I FSD FC 20'x20• RA B 44"x32' & 44'x12' \ BY OTHERS. •• -'. 3 8•f �x - LAW LEVEL - HIGH LEVEL S \ SP FD ID \\ LLJJ 44'x14' TB. 6'f PVC FOR . \1 . ■ , G 4 ❑ m GlF AIR DUCT. AL(INSULATION ON OUTDOOR COMBUSTION AIR. , P \ S-1 R-1 S-1 30e - •.- ❑ , FIRE RATED NCLOURE 10"00 24'x12' 1200 /Y END SWITCH pN CO/NOi2-3 BY OTHERS. ND SNITCH ON CO/N022-2 T� WRED TO GTF-2-4. WRED TOG 2-5. EXHAUST USTPVC FOR I \\ EXHAUST FLUE. / \ / HP �1-a I I G1F 6'0 6'0 SEPARATION BETWEEN INTAKE - El AND EXHAUST: MINIMUM 1'-6' AND MAXIMUM 5'-0'. EXHAUST 6' MINIMUM FROM / WALL - \ / // HP INTAKE TO BE A DOWNTURN / ELBOW. OW.t� \\ // 4 L-1 2Yx18' /NO 2,-3 2-1 /N0)2 -----------CONDUIT - - - - - - - - - - - - - - - - - - - - - ------�� -7---------------(1L1_f CONDUIT ------- 3P '�"- NO2SENSOR S NSOR'051-6'AFF AFF ND SWITCH ON CO/NO22-1 NHEEL STOPS WRED TO GTF-2-2 & 3. I (BY OTHERS). I I I I I OI I I I HP I 4'-O'x7'-6" TRANSFER 8 _ FROM LEVEL 1 TO VENTILATE I GE LEVEL 1. GRATE BY • I OTHERS. I 4'-0'x4'-O" TRANSFER ■ I FROM LEVEL 1 TO I . I VENTILATE GARAGE I , LEVEL 1. GRATE BY OTHERS. I I I I I sl �I I ®I I I I I I I I I I I I I I I I I . 1 Mp 2-5 I CONDUIT IN SLp6 ABOVE BY CONTROLS COOOOFtttJJJ1TTTiRRRRACTOR. WRING IN CONDUIT BY \ END OF LINE FOR CONTROLS CONTRACTOR. 2-4 - \\ CONTROLS CIRCUIT / \ /N0 2-8 / 0190 1 i 19-- 1 ENCLOSED PARKING RA VENTILATION, FSO LEVEL 1: 23,121 S.F. 0 0.75 CFM PER IF = 11,311 CFM LEVEL 2: 27,915 S.F. 0 0.75 CFM PER IF = 20,940 CFM / \ ` 10'x10" FA LEVEL 1 & 2: TOTAL OF 38,400 CFM � PROVIDE (3) IZ800 CFM GARAGE EXHAUST FANS FIRE RATED \ GEF-2-1 TO GEF-2-3 FOR A TOTAL OF 38,400 CFM. / \\ ENCLOSURE BY / 8'-9" 4'-3' z 4'-3' OPENING OPENING \ t0z6° OTHERS. \ JUNCTION BOX N SLAB. TYPICAL LREVI'EVVED 1 + / GEF GEF GEF \ Vf D - - - - _ - - - - - - 1"f CONDUIT \ 1"f CONDUIT .. // 2-1 -2 -3 \ --IOU-- / - - - - - - - - ND SWTTXH I CO/NO22-6 WRED TO GTF-k-6. VFDS FOR GARAGEEXHAUST FANS 1O FANS USPENDED FROM GEF-2-1 TO GEF-2-3STRUCTURE WTH 2' STATIC MOUNTED VERTICALLY 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (VTHP). UP / DEFLECTION SPRING ISOLATION ON WALL \ BE TYPE IS-1 (LIVING ROOM - 12'x8', BEDROOM - 12"W). FLEXIBLE DUCT TO GRILLES HANGERS. , (LIVING ROOM - 10"0, BEDROOM - 8"0). 2. APARTME TS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE ( SUPPLIED�AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEALER SHALL BE INTERLOCKED TO FLEXIBLE DUCT CONNEC110N. ��- O P THE VTAr� TO ENURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 WSEC ND SWITCH ON CO/NO22- / 4 ) 3. KITCHEN EXHAUSTODUCTS SHALL BE CONSTRUCTED OF 6'0 GALVANIZED STEEL WITH SMOOTH WRED TO GTF-2-1. / INTERIOR (IFINISH AND TO BE AIR TIGHT. 4. DRYER DI'CTING SHALL BE 4"0 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED WITH BACKDRAFFFFFFTTTTTT DAMPER. NO SCREWS. 5. TOILET RQOAMBUCT1 G ALL BE CONSTRUCTED OF 5'0 GALVANIZED STEEL WTH SMOOTH INTERIOR d �v 1 G1F FINISH D TO SHALL BE AIR TIGHT. DUCT SERVING MULTIPLE TOILET ROOM FAN(S) SHALL BE 6'0. `i x \ Y_6 6. KITCHEN, DRYER, TOILET ROOM EXHAUST HOOD SHALL BE 3'-0' FROM ANY OPERABLE OPENINGS. ❑'"' �o " iv (EXHAUS HOOD BY OTHERS). GTF 0D I } 7. OUTDOOR AIR TO APARTMENTS THROUGH WNDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 2-1 a i i BEDRO� APARTMENTS: THREE (3) TITON TRIM VENT 9M (4 SO.IN. EACH). Q Q 2 BEDROOM APARTMENTS: FIVE (5) TITON TRIM VENT SM (4 SO.IN. EACH). 0 , 8. DRYER SE1S SHALLHAVE A 20' WIDE x 14' HIGH GRILLE IN EACH DOOR. 9. INTERIOR EDROOMS SHALL HAVE MECHANICAL CATION. TRANSFER FAN TF-1. L-1 GARAGE EXHAUST LOUVER. 10'-0' LENGTH L_i GARAGE EXHAUST LOUVER. 10.DRYERS BE WHIRLPOOL MODEL WTD7IHEDW ON VENT (SUPPLIED BY OWNER). MAXIMUM DUCT MINIMUM 3'-0' TO OPERABLE OF 2' THICK MINIMUM 3'-T TO OPERABLE LENGTH IS 160 FEET WITH NO 90' ELBOWS. SU 10 FEET FROM MAXIMUM LENGTH FOR EACH 104'x50` OPENINGS. DUCT LINING. 50'x50' OPENINGS. 90' ELBO . I OCEAN PAMI RR MECHANICAL 0M. MW INTER URBAN AVE TELEPHONE 2088744663 SEATRS, WA 98M FAMAN E 20f8744O84 STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 1--l- DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT 05/24/2018 REVIEW RECEIVED CITY OF TUKWIL. ,E NOV 2 0 2019 PERMIT CENTER D AWING TITLE EVEL 2 MECHANICAL DATE MAY 2018 DRAWN BY DL SCALE A"=1'-0" M1.2