MECHANICAL PERMIT
2623049008 Permit Number: W119'0192
Project Name: RESMK4|'SGROUP INC
Issue Date: 12/27/2019
Permit Expires On: 6/24/2020
Owner:
AANGANPROPERTIES LL[
4l54I33ZNDPi'FEDERAL WAY, WA,
98001
Contact Person:
Name: lAKUAY[HAVVLA/ZAFAR|QB4L Phone: (286)575-0050
Address: 1l20ANDOVERPARK [,TUKVV|LA,
VVA'981D8
Contractor:
Name: ZIP MECHANICAL
Phone: (206)861-2512
License No: Z|PMEM~842KD Expiration Date: 5/4/2020
Lender:
Address:
'''
�
DESCRIPTION OFWORK:
ISSUED PREVIOUSLY 0mPERMIT: W1I7f0018:ADDITION OF4O'X30',(Z)DOOR WALK |NFREEZER TONVVCORNER
OF EXISTING WAREHOUSE.CONCRETE SLAB ALSO REMOVED AND REPLACED WITH REDIANT HEATING.
COMPRESSOR WILL BE OUTSIDE OF BLDG ON CONCRETE SLAB. CONSTRUCTION PLANNED TO BEGIN IN THE FIRST
HALF OFNEXT YEAR.
Valuation of Work: $25,000.00
Type nfWork: NEW
Fuel type: ELECT
Fees Collected: $530.64
Electrical Service Provided by: PUGETSOUND ENERGY
Water District: TUKVV|LA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
ized Signature:
National Electrical Code:
VVACities Electrical Code:
VV4[296~Y6B:
WA State Energy Code:
Date:
05 21
05 21
2017
2017
2017
| hearby certify that | have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. | am authorized to sign and obtain this
development permit and agree tothe conditions attached tothis permit.
Signature:
Print Name:
Date:
This permit shall become null and void if the work isnot commenced within ID0days for the date ufissuance, or if
the work is suspended orabandoned for aperiod ofl8Odays from the last inspection.
PERMIT CONDITIONS:
J: Fire protection systems shall be maintained in accordance with the original installation standards for that
system. Required systems shall be extended, altered or augmented as necessary to maintain and continue
protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems
shall bedone inaccordance with applicable standards. (|FC9OI.4)(EXTENDSPRINKLER PROTECTION TO
THE WALK-IN FREEZERj
1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval ofdrawings prior toinstallation ormodification. New sprinkler systems and all
modifications tosprinkler systems involving more than S0heads shall have the written approval ofFactory
mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior tosubmittal tnthe Tukwila Fire Prevention Bureau. Mosprinkler work shall commence
without approved drawings. (City Ordinance No. Z436).
Z: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#Z436and #2437)
4: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval ofsuch condition orviolation.
S: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at(ZO6)57S'4407.
6: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
7: Manufacturers installation instructions shall beavailable onthe job site at the time ofinspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (2o6)438'g35o
1400 FIRE FINAL
I800 MECHANICAL FINAL
0701 ROUGH'|NK4E[HAN|[AL
CITY OF TUKW1
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. IT (
Project No.
Date Application Accepted: /2-Z. 4c7
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 2623049098
Site Address: 1120 Andover Park E, Tukwila WA 98188 Suite Number: Floor: GF
Tenant Name:
Reshmi's Group Inc
PROPERTY OWNER
Name: Aangan Properties LLC
Address: 1120 Andover Park E
City: Tukwila State: WA
Zip: 98188
CONTACT PERSON — person receiving all project
communication
Name: Sanjay Chawla / Zafar Igba1
Address: 1120 Andover Park E
City: Tukwila State: WA Zip: 98188
Phone: (206) 575-0050 Fax: (866) 935-3247
Email: accounting@reshmisgroup.com
New Tenant: ❑ Yes E .. No
MECHANICAL CONTRACTOR INFORMATION
Company Name: ZIP MECHANICAL
Address: 5538 S. Avon St.
City: Seattle State: WA Zip: 98178
Phone: (206) 861-2512 Fax:
Contr Reg No.: ZIPMEM*842KD Exp Date: 04/15/2020
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 25,000
Describe the scope of work in detail:
We would like add 40' x 30' walk in freezer inside our existing warehouse. It will be on north west corner of the warehouse with
two doors (one slinding and a small door). The floor level will be the same as existing level where existing slab will be removed
and new one will be constructed with rediant heating. The compressor will be outside of building sitting on the concerete slab. We
have planned to construct in the first half of next year. Frevioy� O iSSvtect) ni I7 - 601 e.
Use: Residential: New ❑ Replacement ❑ 6
Commercial: New 0 Replacement ❑
Fuel Type: Electric.....
Gas ❑
Other:
H:\Applicalions\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/I,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8,22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Sa
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-lOpm);
Testing of backup generators during the day.
rday, Sunday and State -recognized holidays.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: Date: 12/02/2019
Print Name: Sanjay Chawla Day Telephone: (253) 217-7166
Mailing Address: 1120 Andover Park E Tukwila WA 98188
City State Zip
HAApplicationsTorms-Applications On Line\2016 ApplicationsWeehanical Permit Application Revised I-4-16.docx
Revised: January 2016
Page 2 of 2
Receipt Number
R19185
DESCRIPTIONS ACCOUNT QUANTITY
PermitTRAK
PAID
530.64
M19-0192 Address: 1120 ANDOVER PARK E Apn: 2623049098
$530.64
MECHANICAL
$510.23
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100,00.00
0.00
$375.03
PLAN CHECK FEE
R000322.102.00.00
0.00
S102.05
TECHNOLOGY FEE
$20.41
TECHNOLOGY FEE
R000.322,900.04.00
0.00
$20.41
TOTAL; FEES PAID BY RECEIPT: R19185
$530.64
Date Paid: Monday, December 02, 2019
Paid By: AANGAN PROPERTIES LLC
Pay Method: CHECK 1012
Printed: Monday. December 02. 2019 4:05 PM 1 of 1
el171111
Permit Number: M19-0192
Permit Inspections
City of Tukwila
Description: RESHMI'S GROUP INC
Applied: 12/2/2019 Approved: 12/26/2019 Site Address: 1120 ANDOVER PARK E
Issued: 12/27/2019 Finaled:
Status: EXPIRED
Parent Permit:
Parent Project:
Details:
City, State Zip Code:TUKWILA, WA98188
Applicant: RESHMI'S GROUP INC
Owner: AANGAN PROPERTIES LLC
Contractor: ZIP MECHANICAL
ISSUED PREVIOUSLY ON PERMIT: M17-0018: ADDITION OF 40' X 30', (2) DOOR WALK IN FREEZER TO NW CORNER OF EXISTING
WAREHOUSE.CONCRETE SLAB ALSO REMOVED AND REPLACED WITH REDIANT HEATING. COMPRESSOR WILL BE OUTSIDE OF BLDG ON
CONCRETE SLAB. CONSTRUCTION PLANNED TO BEGIN IN THE FIRST HALF OF NEXT YEAR.
Engineering calculations and revised plans submitted to relocate compressor from outside to roof. Additional plan review fees
required. jh
1i1 INSPEGTIONS
SCHEDULED DATE
COMPLETED,DATE
TYPE
INSPECTOR
RESULT
REMARKS
MECHANICAL. FINAL
Bill Centen
Notes:
SPRINKLERS
BEN HAYMAN
Notes:
FIRE FINAL
BEN HAYMAN
Notes:
12/22/2020 AM
12/22/2020
ROUGH -IN
MECHANICAL
Darrin Graham
APPROVED
425-445-9006
Notes:
Printed: Tuesday, 06 July, 2021 1 of 1
SUPERION
Ci5ERMFT Cr) RD COPY (::)
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M19-0192 DATE: 12/2/2019
PROJECT NAME: RESHMI'S GROUP INC
SITE ADDRESS: 1120 ANDOVER PARK E
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works Structural
PRELIMINARY REVIEW:
Not Applicable ri
(no approval/review required)
ArtA
Fire Prevention
Lil
Planning Division
Permit Coordinator
r
1
DATE: 12/3/19
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12/31/2019
Approved
Corrections Required
E
LI
(corrections entered in Reviews)
Approved with Conditions
—
Denied
Denied
(ie: Zoning Issues
Notation:
LI
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
12/18/2013
0 Some online services are currently unavai able, See a list of service outages. (httos://In'. a.goviagency/system-stalus)
\40 Labor & Industries (https://lni,wa.gov)
Contractors
122 MECHANICAL
Owner or tradesperson
Principals
DZIP, HOA TRUNG, PARTNER/MEMBER
Doing business as
ZIP MECHANICAL
WA 1.)B1 No.
603 609 185
Parent company
Zip Mechanical LLC
5538 SOUTH AVON ST
SEATTLE, WA 98178
206-861-2512
KING County
Business type
Limited Liability Company
Governing persons
HOA
T
DZIP
HUNG DZIP;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active
Meets current requirements.
License specialties
GENERAL
License no.
ZIPMEM*842KD
Effective — expiration
05/04/2016— 05/04/2020
Bond
Wesco Insurance Co
Bond account no
46WB075151
$12,000 00
Received by L&I Effective date
05/04/2016 05/0312016
Expiration date
Until Canceled
Insurance
Security National Insurance $1,000,000.00
Policy no.
NA115450303
Received by L&I Effective date
04/12/2019 04/15/2019
Expiration date
04/15/2020
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
I I
— _ — — — — — — _-- — — — — — — — — — —
98'-2"
EXISTING ROOF OUTLINE
(NO CHANGE)
------- ---- —
I
o� I (E) STEEL POST
------------ (6TOTAL)
170"(L) x 45"(W x 5 " (t., I
ROOF TOP UNIT. MAX _l� /!Za
WEIGHT = 1870 L.ES
95°°`'` r''�`'`` D EXISTING STORAGE
FILL P- �OVc:
�~ RAMP' :.:_Ag
METAL.
FREEZER
FREEZER FLOOR
,. _ C x8' IDiNG
t =' DOOR
•
r '
---------
1
! j FREEZER
L
r 12' R=TAHN NG WALL. OFFICE SPACE
EXISTING PARKING AREA
213.76' �.
I
ANDOVER PARK EAST
SITE PLAN
20' 0 10' 20' 40'
SCALE: 1" = 20'
8" CONC SLAB W/ #5
@12"ocEWAT
EXISTING 14" v o v v. MID -DEPTH OF SLAB
SLAB ON
GRADE nsulation Barrier 4" to 6"
COMPRESSIVE
STRENGTH 30 PSI MIN
VAPOR BARRIER
SEPARATE_ PERMIT
2x10 REDWOOD U VV V U U Aggregate (sand, gravel) E UI �D O Ql
(THERMAL-BREA U ° [,'Electrical
K) AROUND E�r Plumbing
PERIMETER [-Gas Piping
v a v City of Tukwila
4" SLAB ON GRADE BUILDING DIVISION
SAWCUT
EXIST SLAB HEATING MAT - 1/2" RED NOTE:
FOR THE NEW PEX TUBING CONTRACTOR / OWNER SHALL HAVE
FREEZER A PLAN FOR LONG-TERM
SLAB MAINTENENCE FOR THE FREEZER
FLOOR.
FREEZER FLOOR ASSEMBLY 6
?Qn COCtif}t M d0ft
.A 1 r ._ • c , +nq momei r00e'3=
? + 30 .): e v F�ela Cone and
.y�y7 a •-cw ecw�ec
d C]YhGj_
Ott —
3'-0" --NEW FREEZER SLAB
#5 F— @ 12" oc.- Lr;
-UNDERLAYER ASSEMBLY
---- r �— '\ REF DETAIL 6/S2
8" CONIC WALL w/ #5 VERT @ 12"--
I
l
oc, #4 HORIZ @ 12" oc. PLACE—
VERT. AT CENTER OF WALL TYP. h j ---' 9.5% COMPACT FILL
L�
DRILL IN AND EPDXY INTO EXIST \`
WALL 4" EMBED BY HILTI HIT xd REVISIONS
HY-200 RESIN.
a new Nan,
\\ --EXIST SLAB Cd! Q aiiianal plan revWx,
GRADE RAMF*" "'-
\---♦=XIST CONIC WALL � Vr
INTENTIONALLY ROUGHEN
EXIST SURFACE TO 4"
AMPLITUDE _.._
--EXIST FOOTING
1 .5R6/
EXPIJU
RETAINING WALL SECTION 12 JUN242021 11/13/19
D
TUK%%ILA
W
SCE 0 2 2019 U)
R%!G CENTER D
CONSTRUCTION SEQUENCE NOTES:
t., 2 1 . Q
2
LU :5
1. SAWCUT EXISTING SLAB;
2. EXCAVATE TO EXPOSE EXISTING PANEL WALL FOOTING;° .._.. Q
3. MEASURE THE EXISTING FOOTING SIZE AND REPORT TO ENGINEER;
4. AFTER ENGINEER EVALUATE THE EXISTING CONDITION, CONSTRUCT CONIC RETAINING WALL;
5. BACKFILL AND COMPACT THE SOIL PER STRUCTURAL DETAIL;
6. CONSTRUCT FREEZER FLOOR ASSEMBLY; 19--_0
7. MOVE THE FREEZER COMPRESSOR TO THE EXISTING CONC PAD OUTSIDE OF BLDG;
8. INSTALL THE FREEZER DUCT; �Yapproval stamp
9. INSTALL NEW DOOR AND WALL FRAMING. NOTE THAT EXISTING ROLLING DOOR TO REMAIN. NEW
RETAINING WALL TO BE BUILT INSDIE THE ROLLING DOOR E
m
>CL
Z
a
NTP Engineers
16507 NE 50th St - Redmond WA 98052
housedesign4u@outlook.com 425-891-5111
GENERAL STRUCTURAL NOTES
2015 INTERNATION BUILDIN CODE (IBC 2015)
CRITERIA
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,
SPECIFICATIONS, THE INTERNATIONAL BUILDING CODE (IBC)(2012 EDITION).
2. DESIGN LOADING CRITERIA
ACTIVE SOIL PRESSURE............................................................ 40 PCF (ASSUMED)
PASSIVE SOIL PRESSURE........................................................ 250 PCF (ASSUMED)
SOIL FRICTION....................................................................... 0.3 (ASSUMED)
SURCHARGE AT FREEEZER..................................................... 250 PSF
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR
BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR
COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS
SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL DIMENSION CONTROL IS DEFINED
BY THE ARCHITECTURAL WALL SECTIONS, BUILDING SECTIONS, AND PLANS. DETAILING AND SHOP DRAWING
PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL
COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS,
TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE
STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT
RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING
FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT,
SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER,
CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE.
7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND
STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON
SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT.
8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE
NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE
STRUCTURAL ENGINEER.
9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED
SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND
ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER.
GEOTECHNICAL
10. IF SOILS ARE FOUND TO BE OTHER THAN SPECIFIED BELOW, NOTIFY THE STRUCTURAL ENGINEER FOR
POSSIBLE FOUNDATION REDESIGN.
FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE.
FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNO.
BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR
SUBSURFACE DRAINAGE.
ALLOWABLE SOIL PRESSURE.................................................................. 2000 PSF
CONCRETE
11. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH ACI 318
AND ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF fc = 3,000
PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE
PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING
WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND
C618. TOTAL AIR CONTENT FOR FROST -RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318-11,
TABLE 4,4.1.
12. THE MINIMUM AMOUNTS OF CEMENT MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS
SUBMITTED TO THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS
PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE
AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CEMENT RATIO, SLUMP,
CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI 318-14, THE USE OF A
PERFORMANCE MIX REQUIRES BATCH PLANT INSPECTION, THE COST OF WHICH SHALL BE PAID BY THE
GENERAL CONTRACTOR. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT
INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER
MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE.
13. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy =
60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064.
14. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH
318-14. LAP ALL CONTINUOUS REINFORCEMENT #6 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM.
PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40
BAR DIAMETERS OR 2'-0" MINIMUM, LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI
318-14, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS.
NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO
DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER.
15. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED
TO EARTH • 3"
FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER)..... 2"
FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER) ..... 1-1/2"
SLABS AND WALLS (INT FACE) ............ GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4"
ANCHORAGE
16. EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS
SHALL BE INSTALLED USING "HIT HY200" EPDXY ADHESIVE AS MANUFACTURED BY THE HILTI COMPANY.
INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-3187. SUBSTITUTIONS PROPOSED BY THE
CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH CURRENT ICC REPORTS INDICATING EQUIVALENT OR
GREATER LOAD CAPACITIES. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED, RODS SHALL BE ASTM A-36,
UNO.
17. HEAVY DUTY THREADED CONCRETE ANCHORS SPECIFIED ON THE DRAWINGS SHALL BE "TITEN HD
SCREW ANCHOR" AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY, INSTALL IN STRICT
ACCORDANCE WITH ICC-ES REPORT ESR-2713, INCLUDING MINIMUM EMBEDMENT AND EDGE DISTANCE
REQUIREMENTS. SUBSTITUTIONS PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH
ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES.
18. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "STRONG -BOLT"
ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT
CONFORMANCE TO ICC-ES REPORT ESR-1771, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS
INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL
INSPECTION IS REQUIRED FOR ALL EXPANSION BOLT INSTALLATION.
19. DRIVE PINS AND OTHER POWDER -ACTUATED FASTENERS SHALL BE LOW VELOCITY TYPE (PDPWL-
300MG, 0.145" DIAMETER, UNO) AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY OR AN
APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. INSTALL IN STRICT ACCORDANCE WITH ICC-ES
REPORT ESR-2138, MINIMUM EMBEDMENT IN CONCRETE SHALL BE 1", UNO. MAINTAIN AT LEAST 3" TO
NEAREST CONCRETE EDGE.
RECENED
CITY 0;= TUKWILA
DEC 0 2 20+9
PERMIT CENTER
�Yapproval stamp
E
0
a
NTP Engineers
16507 NE 50th St - Redmond WA 98052
housedesign4u@outlook.com 425-891-5111
tr /1?dwd) ICIA
NO.
S1
J