Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M19-0198 - HOME FURNISHINGS - SPLIT SYSTEM REPLACEMENT
HOME FURNISHINGS 16705 Southcenter Pkwy Complex M19-0198 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 5379200310 Permit Number: M19-0198 16705 SOUTHCENTER PKWY COMPLEX Issue Date: Permit Expires On: Project Name: HOME FURNISHINGS 2/11/2020 8/9/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: IMOT LLC 225 ANDOVER PK W #88158 , TUKWILA, WA, 98138 ERIC OKEEFE 1012 CENTRAL AVE S , KENT, WA, 98032 PERFORMANCE HEATING & A/C INC (CONST) 1012 CENTRAL AVE S , KENT, WA, 98032 PERFOHA150RT Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: 4/30/2021 DESCRIPTION OF WORK: REPLACEMENT OF A BROKEN SPLIT SYSTEM LIKE FOR LIKE. WE ARE ONLY REPLACING THE HEAT PUMP AND AIR HANDLING UNIT. WE ARE REUSING THE EXISTING REFRIGERATION LINES AND OTHER CONNECTIONS. Valuation of Work: $11,248.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $368.13 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: 4-''- "ti'"'"'%%""'" Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction nrthe performance ofwork. |amauthorized kzsign and obtain this development permit and agree tnthe conditions attached tnthis permit. ` Signature: Date: 07 / /) /��b]i{} Print Name: � �^.'[ F> This permit shall become null and void if the work bnot commenced within l8Odays for the date o{issuance, orif the work issuspended nrabandoned for aperiod of1QOdays from the last inspection. PERMIT CONDITIONS: 1: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building inspector until final inspection approval is granted. 2: Manufacturers installation instructions shall heavailable onthe job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit inspection Line: (2Ou) 438'9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA,gov Mechanical Permit No. Mil O(' Project No. Date Application Accepted: id— 1 0 / 9 Date Application Expires: (Q * I 0 —2O (For ofce use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 537920 0310 Site Address: 16705 SOUTHCENTER PKWY Suite Number: n/a Floor: n/a Tenant Name: Home Furnishings New Tenant: ❑ .....Yes ® ..No PROPERTY OWNER Name: RETAIL CENTER LLC Address: C/O 5530 E LK SAMM PKWY SE City: ISSAQUAH State: WA Zip: 98029 CONTACT PERSON — person receiving all project communication Name: Eric O'Keefe _.., Address: 1012 Central AVE S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: Email: eric.o@pmghcac.com MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central AVE S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: Contr Reg No.: PERFOH15ORT Exp Date: 04/30/2021 Tukwila Business License No.: BUS-0992987 Valuation of project (contractor's bid price): $ 11,248 Describe the scope of work in detail: REPLACEMNET OD A BROKEN SPLIT SYSTEM LIKE FOR LIKE. WE ARE ONLY REPLACING THE HEAT PUMP AND AIR HANDLING UNIT. WE ARE REUSING THE EXISTING REFRIGERATION LINES AND OTHER CONNECTIONS. Use:, Residential: New ❑ Replacement ❑ Commercial: New .......... ❑ Replacement 1111 Fuel Type: Electric IZ Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 1 of 2 • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and SAM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 12/09/2019 Print Name: ERIC O'KEEI-E Day Telephone: (425) 251-0356 Mailing Address: 1012 Central AVE S Kent WA 98032 City State Zip H:V‘pplications1Formu-Applications On Line\2016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $368.13 M19-0198 Address: 16705 SOUTHCENTER PKWY COMPLEX Apn: 5379200310 $368.13 Credit Card Fee $10.72 Credit Card Fee R000.369.908.00.00 0.00 $10.72 MECHANICAL $343.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322,100.00.00 0.00 $241.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $68.73 TECHNOLOGY FEE $13.75 TECHNOLOGY FEE TOTAL. FEES PAID BY RECEIPT: R19258 R000.322.900.04.00 0.00 $13.75 $368.13 Date Paid: Tuesday, December 10, 2019 Paid By: ERIK OKEEFE Pay Method: CREDIT CARD 065347 Printed: Tuesday. December 10. 2019 3:51 PM 1 of 1 CO TUKWILA ETK4KIT 0200 8)VTVCENTER 8LVD TUKWILA' WA 98188 206'433z878 CITY OF TUKWILA 0017340000802374404500 Date: 12/10/2019 03:50:32 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: *******+*95I8 K TRAN AMOUNT: $368.13 APPROVAL [D: 065347 RECORD #: 008 CLERK ID: frankie X {CARDHOLDER'S SIGNATURE) I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: /l 7cS S-cm spate R&i /CaMiteY Called: Special Instructions: 5/ii Sr- SYs 7 , eratew r Date Wanted: 3. 2GS- Z� a.m. p.m. Requester: O>s. V2 -s Z --6 3 5(0 Phone No: d, Approved per applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectmn. Performance Mechanical Group Job: South Center Submittal Split System Heat Pump 208-230V MODEL 4TWA4060A3000A REVIEWED FOR CODE COMPLIANCE APPROVED DEC 20 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 10 2019 PERMIT CENTER Note: "Graphics in this document are for representation only. Actual model may differ in appearance." TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2017 4TWA4060A—SUB-3 B-E N C Ingersoll Ranch Outline Drawing SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 15 FEET! ABOVE UNIT. UNIT SHOULD BE PLACED 50 ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112'I FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 4 ELECTRICAL SERVICE RANEE 25 tI) 22.2 17/81 DIA. HOLE LOW VOLTAGE 28.6 11-I/8) DIA. N.O. WITH 22.2 17/81 DIA, HOLE IN CONTROL 801 BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE, 'E' I.D. FEMALE BRAZE CONNECTION WITH 1/4' SAE .E1/4ARE PRESSURE TAP FITTINGS. n 1 11 A J FOR ALTERNATE CIRICAL ROUTING GAS LINE I/4 10RN BALL SERVICE VALVE, 'D' I.D. FEMALE BRAZED CONNECTION WITH Il4' SAE FLARE PRESSURE TAP FITTING. Model •, •Base A f B al C D E F 6 11 7 K 4TWA4060A3 q 1147 (45-1/8) 946 (37-1/4) 870 {34-1/4) 410 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 813 (32) Sound Power Level MODEL A -Weighted Sound Power Level (dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWA4060A3 74 72 72 71 69 70 62 57 52 2 4TWA4060A-SUB-3B-EN TRAM' Product Specifications OUTDOOR UNIT (a) (b) 4TWA4060A3000A POWER CONNS. — V/PH/HZ V) 208-230/3/60 MIN. BRCH. OR. AMPACITY 21 BR. CIR. PROT. RTG, — MAX, (AMPS) 35 COMPRESSOR CLIMATUFF®-SCROLL NO. USED — NO. STAGES VOLTS/PH/HZ 208-230/3/60 R,L, AMPS (d) — L.R. AMPS 15.9 — 110 FACTORY INSTALLED START COMPONENTS (a) NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.6 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. (f) 4785 NO. MOTORS — HP 1 — 1/5 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 200-230/1/60 F.L. AMPS 1.1 OUTDOOR COIL — TYPE SPINE FIN'" ROWS — F. P. I. 2 — 24 FACE AREA (SQ. FT.) 29.15 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS. — R-410A (O.D. UNIT) (9) 10 LBS., 9 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) () 1-1/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOUNG 8°F DIMENSIONS H X W X D CRATED (IN.) 51x 38.7 x 35.1 WEIGHT SHIPPING (LBS.) 325 NET (LBS.) 275 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (9) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes, Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (l) Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (l.) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide 5S- APGD06-xx for long line sets or specialty applications (xx denotes latest revision). (1) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for full charging instructions. 471A/A4060A—SUB-3B-EN qV rAME. Mechanical Specification Options General The Outdoor Units are fully charged from the factory for upto 15feet ofpiping. This unit iadesigned tn operate atoutdoor ambient temperatures ashigh oa 115"F.Cooling capacities are matched with awide selection ofair handlers and furnace coils that are AHR| certified. The unit iocertified \nUL1895.Exterior in designed for outdoor application. Casing Unit casing iuconstructed ofheavy gauge, galvanized otao| and painted with aweather-resistant powder paint finish, The corner panels are p,apaintod.All panels are subjected toour 1.UUOhour salt spray test . Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. Afactory supplied, field installed liquid line drier iostandard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The aluminum plate fin, copper tube outdoor coil provides low airflow resistance and offi,inru heat transfer. The coil is protected with a corrosion resistant mesh coil guard. Low Ambient Cooling Asmanufactured, this system has acooling capacity tu 55~F.The addition ofanevaporator defrost control permits operation to40"F.The addition ofan evaporator defrost control with T%Vpermits low ambient cooling to30"F. The addition ofthe BAYLOAN11U7Alow ambient kit permits ambient cooling to20"F. Thermostats— Cooling only and heat/cooling (manual and automatic change ovo,). Sub -base tomatch thermostat and locking thermostat cover. 4 4lW:406ox-SVB'3o-sw (t11") Ingersoll Rand® Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club Car®, Ingersoll Rand®, Thermo King® and Tranee— work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency, We are a global business committed to a world of sustainable progress and enduring results. Club Car OPIngersoll Rand. THERMO KING MANE ingersollrand.com eCCERTIFJED.,-1 ww ah rid tr ector y.0 *9 :11 . . - Unitary Small HP , '47,14i131 Standard 210/240 - -- tertlitreknapOnagywhanilteroVite$p;Itin',"^., Intertek The AHRI Certified mark indicates Ingersoll Rand participation in the AHRI Certification program, For verification of individual certified products, go to www.ahridirectory.org. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4TVVA4060A—SUB-3B-EN 27 Oct 2017 Supersedes 4TVVA4060A—SUB-3A•EN (November 2016) ©2017 Ingersoll Rand Variable Speed Convertible Air Handler 5 Ton TEM6A0D6OH51SB Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications. Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2018 TEM6A0D6O-SUB-1E_EN (i1) Ingersoll Rand. Outline Drawing MINIMUM UNIT CL[ARANCE (ABLE SERVICE CLEARANCE (RECOMMENDED' 510ES 2' FRONT 21' DACE 0" INLET DUCT OUTLET DUCT NIA NOTE:THIS UNIT 15 APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE MATERIAL A5 STATED ONTHE UNIT RATING NAMEPLATE 2.12 �+ 2.12_1 F PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control Gas Line Braze TEM6A0D6OH5156 53.87 26.50 24.50 24.75 7.01 9.66 27.19 TXV 7/8 All dimensions are in inches 2 TEM6A0D60-SUB-1 E-EN Product Specifications MODEL TEM6A0D6OH51SB RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a) See O.D. Specifications INDOOR COIL — Type Plate Fin Rows — F.P.I. 4-16 Face Area (sq. ft.) 6.47 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Centrifugal Diameter -Width (In.) 11 X 11 No. Used Drive - No. Speeds Direct - 16 CFM vs. in. w.g. See Fan Performance Table No. Motors — H.P. 1 - 3/4 Motor Speed R.P.M. Variable Volts/Ph/Hz 208-230/1/60 F.L. Amps 6.8 FILTER Filter Furnished? (0 No REFRIGERANT R-410A Ref. Line Connections Brazed Coupling or Conn. Size — in. Gas 7/8 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 55-3/8 x 30-1/2 x 25-1/2 Uncrated 53-7/8 x 26-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 181/168 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) (c) Remote filter required. TEM6A0D6O-SUB-1E-EN 3 Minimum Airflow CFM TEM6A0D6OH51SB Heater Minimum Heater Airflow CFM With Heat Pump -Witheut-Heat Pump BAYHTR1504BRK, BAYHTR1504LUG BAYHTR1505BRK, BAYHTR1505LUG 1150 975 BAYHTR1508BRK, BAYHTR1508LUG 1150 975 BAYHTR1510BRK, BAYHTR1510LUG 1150 975 BAYHTR1517BRK 1300 1125 BAYHTR3510LUG 1150 075 BAYHTR3517LUG 1300 1125 BAYHTR1523BRK 1380 1125 BAYHTR1525BRK 1550 1345 TEM6A0D6OH51SB Airflow Performance with Auxiliary Heat Airflow Settings Dip Switch Settings Nominal Airflow See following tables for heater application: - Pressure Drop for Electrical Heaters - Minimum Heating Airflow Matrix (on unit nameplates) Switch 7 Switch 8 Low ON ON 997 Med-Lo OFF ON 1129 Med-Hi ON OFF 1350 High OFF OFF 1597 4 TEM6A0D6O-SUB-1 E-EN Heater Pressure Drop Table Airflow1. CFM Number of Racks Neater Racks 2 3 4 Heater Model No. of Racks Air Pressure Drop - Inches W.G. BAYHTR1504 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR1517 3 1300 0.02 0.04 0.05 0.11 BAYHTR3510 1200 0.01 0.04 0.05 0.10 BAYHTR3517 1100 0.01 0.03 0.05 0.09 BAYHTR3515 3 1000 0.01 0.03 0.04 0.09 BAYHTR1522 4 900 0.01 0.03 0.04 0.08 BAYHTR1523 4 800 0.01 0.03 BAYHTR1525 4 700 0.01 0.02 600 0.01 0.02 TEM6A0D6O-SUB-1E-EN 5 Performance and Electrical Data Table 1. Air Flow Performance TEM6AOD48H41SB, TEM6AOD60H51SB COOLING AIRFLOW PERFORMANCE, WET COIL, NO FILTER, NO HEATER OUTDOOR UNIT SIZE (TONS) SPEED SETTING AIRFLOW SETTING DIP SWITCH SETTING AIRFLOW POWER EXTERNAL STATIC PRESSURE SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 3 LOW 323 CFM/ ton ON ON OFF ON CFM Watts 979 87 978 126 959 170 922 217 867 269 NORMAL 367 CFM/ ton ON ON OFF OFF CFM Watts 1111 124 1113 168 1101 215 1075 265 1036 317 HIGH 415 CFM/ ton ON ON ON OFF CFM Watts 1252 165 1259 214 1254 264 1239 314 1212 364 3.5 LOW 315 CFM/ ton OFF ON OFF ON CFM Watts 1111 124 1113 168 1101 215 1075 265 1036 317 NORMAL 358 CFM/ ton OFF ON OFF OFF CFM Watts 1259 167 1266 217 1261 267 1246 317 1220 368 HIGH 404 CFM/ ton OFF ON ON OFF CFM Watts 1419 223 1428 279 1425 334 1411 389 1386 444 4 LOW 309 CFM/ ton ON OFF OFF ON CFM Watts 1241 161 1248 210 1243 259 1227 309 1201 359 NORMAL 351 CFM/ ton ON OFF OFF OFF CFM Watts 1407 218 1416 273 1413 328 1399 383 1373 437 HIGH 396 CFM/ ton ON OFF ON OFF CFM Watts 1583 296 1593 359 1594 422 1586 485 1570 547 5 LOW 295 CFM/ ton OFF OFF OFF ON CFM Watts 1478 249 1487 307 1486 365 1474 423 1452 481 NORMAL (a) 335 CFM/ ton OFF OFF OFF OFF CFM Watts 1671 344 1681 412 1684 479 1678 545 1635 565 HIGH 379 CFM/ ton OFF OFF ON OFF CFM Watts 1880 476 1892 556 1900 635 1902 714 1760 650 (a) Factory Default Setting Table 2. Air Flow Performance TEM6AOD48H41SB, TEM6AOD60H51SB HEATING AIRFLOW PERFORMANCE, NO FILTER, NO HEATER OUTDOOR UNIT SIZE (TONS) SPEED SE i i ING AIRFLOW SETTING DIP SWITCH SETTING AIRFLOW POWER EXTERNAL STATIC PRESSURE SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 3 LOW 360 CFM/ ton ON ON OFF ON CFM Watts 1087 111 1091 153 1081 199 1055 249 1015 301 NORMAL 400 CFM/ ton ON ON OFF OFF CFM Watts 1205 139 1213 186 1211 234 1198 283 1173 333 HIGH 440 CFM/ ton ON ON ON OFF CFM Watts 1322 175 1333 227 1332 279 1321 332 1297 384 3.5 LOW 347 CFM/ ton OFF ON OFF ON CFM Watts 1219 143 1228 191 1226 240 1213 289 1189 339 NORMAL 386 CFM/ ton OFF ON OFF OFF CFM Watts 1351 184 1363 237 1363 290 1351 344 1328 397 HIGH 424 CFM/ ton OFF ON ON OFF CFM Watts 1482 232 1495 291 1497 349 1489 408 1471 466 4 LOW 351CFM/ ton ON OFF OFF ON CFM Watts 1405 201 1417 256 1418 311 1408 367 1385 422 NORMAL 390 CFM/ ton ON OFF OFF OFF CFM Watts 1555 262 1568 323 1572 385 1567 447 1553 509 HIGH 429 CFM/ ton ON OFF ON OFF CFM Watts 1703 334 1717 403 1723 472 1722 540 1665 560 5 LOW 327 CFM/ ton OFF OFF OFF ON CFM Watts 1625 294 1639 359 1644 424 1641 489 1630 554 NORMAL 363 CFM/ ton OFF OFF OFF OFF CFM Watts 1797 384 1812 459 1820 533 1822 606 1750 615 HIGH 400 CFM( ton OFF OFF ON OFF CFM Watts 1970 495 1986 581 1999 667 2010 740 1910 680 (a) Factory Default Setting 6 TEM6AOD6O-SUB-1 E-EN Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 3. Electrical Data TEM6AOD4SH41SB,TEM6AOD6OH51SB HEATER DATA Heater Model No. No. of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater 6.8 * 9 15 6.8 * 9 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 29 30 2.88 9800 13.8 26 30 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.80 16400 20.0 34 35 3.60 12300 17.3 30 30 BAYHTR1508BRK BAYHTR1S08LUG 1/1 7.68 26200 32.0 49 50 5.76 19700 27.7 43 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1517BRK Circuit 1 (a) 2/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1517BRK Circuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYHTR1523BRK Circuit 1 2/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1523BRK Circuit 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 BAYHTR1525BRK Circuit 1 4/1 6.00 20500 25.0 40 40 4.50 15400 21.6 36 40 BAYHTR1525BRK Circuit 2 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 BAYHTR1525BRK Circuit 3 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 BAYHTR1525BRK Circuit 4 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 BAYHTR351OLUG 1/3 9.60 32800 23.1 36 40 7.20 24600 20.0 33 35 BAYHTR3517LUG 1/3 14.40 49100 34.6 51 60 10.80 36900 30.0 45 45 * = Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps Features and Benefits • Painted metal cabinet with captured foil face insulation • 2% or less air leakage • R-4.2 Insulating Value • Multi -Position UP/Down Flow, Horizontal Left /Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections (sold as accessory) • R-410A Thermal Expansion Valve • Variable Speed ECM Motor Low Voltage Pigtail Connections • Draw Through Design * Horizontal Drain Pan • Single Color • Fused 24V Power • 3 year warranty • 10-year warranty registered • Optional extended warranty available TEM6A0D60-SUB-1 E-EN 7 (IR)Ingersoll Rand Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club Car®, Ingersoll Rand, Thermo King® and Tranee— work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. Club Car Rand. ilE THERMO KING TRANS' ingersollrand.com cOus Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TEMEA0D60-SUB-1E-EN 19 Mar 2018 Supersedes TEM6A0D60-SUB-1D-EN (October 2017) 02016 Ingersoll Rand This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. uct R Ungs AHRI Certified Reference Number : 9964662 AHRI Type : HRCU-A-CB Series : XR14 Outdoor Unit Brand Name : TRANE Outdoor Unit Model Number (Condenser or Single Package) : 4TWA4060A3 Indoor Unit Model Number (Evaporator and/or Air Handler) TEM6A0D6OH51+TDR The manufacturer of this TRANE product is responsible for the rating of this system combination. Date : 10-17-2019 Model Status : Active Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 54500 SEER : 15AX) EER (A2) - Single or High Stage (95F) : 12.50 Heating Capacity (H12) - Single or High Stage (47F) : 52500 HSPF (Region IV) : 9.25 fActive" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on thls Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI, This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or In part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life bet ter' 132156256425457083 -\ \ COORD COPY' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0198 DATE: 12/11/2019 PROJECT NAME: HOME FURNISHINGS SITE ADDRESS: 16705 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Odinffivision Public Works P 1\-1\A c Fire Prevention Structural Planning Division Permit Coordinator • PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 12/12/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n DUE DATE: 1/9/2020 Approved with Conditions Corrections Required 1 J Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg LJ Fire 0 Ping 0 PW 0 StaffInitials: 12/18/2013 LailOY & Indust(https://Intwa.qov) ontractors PERFORMANCE HEATING & A/C INC Owner or tradesperson Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No 600 601 386 1012 Central Ave S KENT, WA 98032 425-251-0356 KING County Business type Corporation Governing persons DANIEL E MILLER DARRIN P ERDAHL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. PERFOHA15ORT Effective — expiration 12/30/1985— 04/30/2021 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 748802C $12,000.00 Received by L&I Effective date 11/27/2007 10/01/2007 Expiration date Until Canceled Insurance Valley Forge Ins Co $1,000,000.00 Policy no. 6076086758 Received by L&I Effective date 04/26/2019 04/28/2019 Expiration date 04/28/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. t ( SPLIT -SYSTEM HEAT PUMP INDOOR UNIT OUTDOOR UNIT MANUFACTURER UNIT HEATING COOLING OSA VOLT/ UNIT HEATING COOLING NOMINAL NOTES NUMBER MODEL gTU BTU CFM CFM PH MCA MOCP WT NUMBER MODEL BTU BTU TON SEER VOLT/PH MCA MOCP WT TRANE AH-1 TEM6AOD6OH51S6 1 52,500 54,500 1150 240 208/1 36 1 40 1 168 LBS CU-1 1 4TWA4060A3000A 1 52,500 54,500 5 15 1 208/3 1 21 35 275 LBS 1,2,3,4 )TES: RATINGS BASED ON AHRI 210/240 PROVIDE W/NEW CONDENSATE PUMP INDOOR UNIT GETS POWER FROM THE OUTDOOR UNIT PROVIDE NEW PROGRAMMABLE T-STAT SPLIT SYSTEM MEETS REQUIREMENTS FOR SPLIT SYSTEMS UNDER OPTION B ON TABLE C503.4 ECONOMIZER COMPLIANCE OPTIONS FOR MECHANICAL ALTERATIONS. REPLACE EXISTING HEAT PUMP WITH A NEW LIKE FOR LIKE 5—TON HEAT PUMP CU-1 ON PLATFORM. PROVIDE SEISMIC ATTACHMENT OF NEW CU-1 TO EXISTING PLATFORM ON GROUND. CONNECT NEW CU-1 TO EXISTING LINE VOLTAGE & LOW VOLTAGE UTILITIES. CONNECT NEW CU-1 TO EXISTING LIQUID LINE & SUCTION LINE. FIL 1E P I Porn � as e�� a Ftv ss .C, a .,,v,c,v oa,e �Zll►Li io ._ REL!SiCh� '-7 IV SCOPE OF WORK: REPLACE AN EXISTING BROKEN HEAT PUMP WITH LIKE FOR LIKE. f4j v°r § i�M ! NOTES: 1. THESE PLANS ARE SCHEMATIC AND MAY NOT REFLECT EXACT ROUTING OR OFFSETS. 2. MATERIALS AND METHODS SHALL COMPLY WITH THE 2015 INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, � gg 0 4 AND INTERNATIONAL FIRE CODE, AS MODIFIED BY WASHINGTON STATE AND LOCAL JURISDICTIONS. DESIGN CONFORMS TO WASHINGTON y g W STATE ENERGY CODE. 3. ALL EQUIPMENT SHALL BE INSTALLED PER 2015 IMC. EXACT LOCATION AND MOUNTING SHALL BE REFLECTED ON STRUCTURAL PLAN. 4. ALL EQUIPMENT MEETS EFFICIENCY REQUIREMENTS OF 2015 WASHINGTON STATE ENERGY CODE. 5. COMMISSIONING OF SYSTEMS PER WSEC C408.2 IS REQUIRED. 5.1. PROVIDE NARRATIVE DESCRIPTION ` OF ACTIVITIES, RESPONSIBILITIES OF THE CX TEAM, AND SCHEDULE OF ACTIVITIES. 5.2. PROVIDE COMPLIANCE CHECKLIST TO OWNER PRIOR TO FINAL INSPECTION LEGAL INFO 5379200310 LEGAL DESC: MC MICKEN HEIGHTS DIV #1 UNREC POR TRACTS 10 & W 11 DESC AS FOLG — BEG SW COR OF NW 1/4 OF SEC 26-23-4 TH S 89-21-31 E 1961.64 FT TO W MGN SOUTHCENTER PARKWAY TH N GO-09-22 W 250 FT TH N 89-21-31 W 6 FT TO W MGN SOUTHCENTER PARKWAY TH CONTG N 89-21-31 W 237.50 FT TO ELY MGN PSH #1 TH N 45-04-23 E 77.18 FT TH N 12-46-41 E 106.52 FT TH N 23-31-36 W 11.76 FT TH S 89-21-31 E 163.37 FT TO W MGN SOUTHCENTER PARKWAY TH S 00-34-46 E 20 FT TH S 00-09-22 E 150 FT TO BEG TGW POR ST HWY UNDER RECORDING NO 84DB210728 & 8411260698 DAF POR OF HERINAFTER DESC PARCEL A LY BTW A LN WCH IS PLW & 345 FT SELY, WHEN MEAS RADIALLY, FR LW LN SURVEY OF SR 5, S178TH ST TO S 126TH ST & A LN DESC AS BAAP OPPOSITE HWY ENGR STA, HEREINAFTER REFERRED TO AS HES, LW 2513+54.06 ON SD LW LN SURVEY & 345 FT SELY THEREFROM TH NELY TAP OPPOSITE HES LW 2514+DO ON SD LW LN SURVEY TAP OPPOSITE HES LW 2515+00 TH NW TAP OPPOSITE HES LW 2515+39.41 ON SD LW LN SURVEY & 345 FT SELY THEREFROM & END OF THIS DESC — PARCEL A — POR OF SE 1/4 OF NW 1/4 OF SEC N Z 26-23-04 — BEG W 1/4 SD SEC 26 TH S 89-21-31 E 1961.64 FT TO WLY MGN OF CO RD TH N 0-09-22 W ALG SD RD MGN 250 FT TO TPOB TH CONTG N 0-09-22 W 170 FT TH N 89-21-31 W 350 FT TH S 0-09-22 E 170 FT TH S 89-21-31 E 350 FT TO TP08 j W Ir RECEIVED N CITY OF TUKWILA v V DEC 0 9 2019 PERMIT CENTER Q D U) Z Q J a J Q _V Z Q 2 V W REVIEWED FOR �TBE COMPLIANCE APPROVED I DIC 20 2019 E ^ity of Tukwila LDiNG DIVISIO � Y = a LU OC _ C� P coo W 00 U Q 5 � J � � Y � � H DATE: 12/05/2019 DRAWN: EO ENGR: EO APPVD: JOB NUMBER: 115287 M-1 1 OF 1 NO