HomeMy WebLinkAboutPermit M19-0207 - SABEY CORPORATION / BUILDING B - NEW ROOFTOP UNIT WITH PROPANE HEAT, DUCTWORK AND DIFFUSERSSABEY IGW - B HQ RENOVATIONS 12201 TUKWILA INTL BLVD 200 FINALED 01/10/2023 M19-0207 Parcel No: Address: City °~fTukwila Department ofCommunity Development 63UUSouthcen1erBoulevard, Suite #1UO Tukwila, Washington 9818A Phone:206'431-367U Inspection Request Line: 206'438'9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0923049120 Permit Number: M19-0207 Project Name: SA8EY|GVV BH[\RENOVATIONS Issue Date: 1/10/2020 Permit Expires On: 7/8/2020 Address: Contact Person: Name: Contractor: Name: License No: Lender: Name: INTERNATIONAL GATEWAY WEST 122O1TUKVV|LAINTERNATIONAL BL, SEATTLE,WA, 9B16D AMMONEBEMBRY 7717DETRO|TAVE SW, SEATTLE WA, 98106 MA[DONALD/M|LLEKFA[SOLINC POBOX 47983,SEATTLE,WA, 98140' 79Q] yWA[DOFS980RU ''' Phone: (206)768-4062 Expiration Date; 1/4/2021 DESCRIPTION OF WORK: INSTALL NEW DXROOFTOP UNIT WITH PROPANE HEAT. INSTALL MEDIUM PRESSURE DUCTWORK, (1O)VAV BOXES, LOW PRESSURE DUCTWORK AND (42) DIFFUSERS TO SERVE SECOND FLOOR OFFICE AREA. Valuation of Work: $188,225.00 Type ofWork: REPLACEMENT Fuel type: GAS Fees Collected: $2,439.27 Electrical Service Provided by: 5EATTLECITY LIGHT Water District: 20 Current Codes adopted by the City of Tukwila: international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 ZOB 2015 National Electrical Code: VVACities Electrical Code: VVA[396-46B: Code: ` ermit Center Authorized Signature; 1/ L I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state nrlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and agree tothe conditions attached to this permit. Signature: Print Name: / Date: / / / ' / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance,or if the work is suspended orabandoned for aperiod ufI80days from the last inspection. PERMIT CONDITIONS: l: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (20G/431-367O). 3: All permits, inspection record card and approved construction documents shall bekept at the site ofwork and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Manufacturers installation instructions shall be available on the job site at the time of inspection. 4: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition isnot less than 1Oinches above the floor surface onwhich the equipment orappliance rests. 5: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436and #Z437) 6: Remote indicator lights are required nnall above ceiling smoke detectors. (City Ordinance #Z437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. Nuwork shall commence until ufire department permit has been obtained. (City Ordinance #Z437)(IFC90l.Z) 8: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U1, central station supervision is required. (City Ordinance #Z437) 9: H.V.AI. systems supplying air in excess cfZ,80Ocubic feet per minute toenclosed spaces within buildings shall beequipped with anautomatic shutoff. Automatic shutoff shall heaccomplished byinterrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (|x4[606.l, 606Il) 10: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Onjinance#Z3Z8) ll: Duct detectors shall send asupervisory signal only upon activation. (City Ordinance #Z437) 12: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 13: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ofsuch condition urviolation. 15: These plans were reviewed byInspector 51l. Ifyou have any questions, please call Tukwila Fire Prevention Bureau at(Z06)5754407. PERMIT INSPECTIONS REQV|nso Permit Inspection Line: (206)43Q'935O 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWAC Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www,TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: M -0)-07 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 0923049120 12201 Tukwila Int. Blvd, Tukwila, WA 98188 Sabey IGW -B HQ Renovations Suite Number: Bldg B Floor: 2,3 roof PROPERTY OWNER Name: SABEY Address: 12201 Tukwila Int. Blvd, City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: AMMONE BEMBRY Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4062 Fax: Email: permits@macmiller.com New Tenant: 1111 Yes V..No MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4062 Fax: Contr Reg No.: MACDOES980RU Exp Date: 01/04/2021 Tukwila Business License No.: BUS-0994318 Valuation of project (contractor's bid price): $ 188,225 Describe the scope of work in detail: INSTALL NEW DX ROOFTOP UNIT WITH PROPANE HEAT. INSTALL MEDIUM PRESSURE DUCTWORK AS SHOWN, ALONG WITH (10) VAV BOXES, LOW PRESSURE DUCTWORK, AND (42) DWI -USERS TO SERVE 2ND FLOOR OFFICE AREA. NEW VAV'S SHALL COMPLY WITH HIGH PERFORMANCE VAV CRITERIA AS SHOWN IN THE WSEC SECTION 403, THE ROOFTOP tiNIT PROVIDED EXCEEDS REOIIIRED EFFICIENCY AND Us: Residential: New El Replacement ID Commercial: New El Replacement Fuel Type: Electric Ei Gas Other: H: Applications' Forms -Applications On Lino20 I 6 Applications:Mechanical Permit Application Revised 1 -4- I6.docx Revised: January 2016 Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Fumace>100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator - domestic Incinerator — com Unit Type Qty Fire damper Diffuser 46 Thermostat Wood/gas stove Emergency generator Other mechanical 1,31 Vxv 3o.es.l9i equipment rze"'�a°^mom 9:, 2 HOnG- 90' .a0n.1n HVAG POoI Mounlea Bailer/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/ 1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-I OPM, Monday through Friday and SAM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the dayti • Testing of backup generators during the day. hours (lam-IOpm); PERMIT APPLICA I`ION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:_ Date: 12/18/2019 Print Name: AMMONE BEMBRY Day Telephone: (206) 768-4062 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip H: Appl icalions-Forms-A pp I ications On I..ine,2016 Applicat ions'Mechanical Permit Application Revised I-4-I 6.docx Revised: January 21116 Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $1,970.18 M19-0207 Address: 12201 TUKWILA INTL BLVD 200 Apn: 0923049120 $1,970.18 MECHANICAL $1,876.36 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000,322.100.00.00 0.00 $1,843.21 TECHNOLOGY FEE $93.82 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19648 R000.322.900.04.00 0.00 $93.82 $1,970.18 Date Paid: Friday, January 10, 2020 Paid By: MACDONALD-MILLER FACILITY SOLU Pay Method: CHECK 4987 Printari• Frirlav lanuary 10. 2020 12:43 PM 1 of 1 • Cash Register Receipt City of Tukwila Receipt Number 149340 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID M19-0207 Address: 12201 TUKWILA INTL BLVD 200 Apn: 0923049120 MECHANICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R19340 R000.322.102.00.00 0.00 $469.09 $469.09 $469.09 $469.09 $469.09 Date Paid: Wednesday, December 18, 2019 Paid By: MACDONALD MILLER FACILITY SOLU Pay Method: CHECK 4980 Printpri• WPrinPcriav DerPmher 1R. 2019 1:21 PM 1 of 1 Submittal Prepared For: M.Contractor: MacDonald -Miller Facility Solution Sold To: FILE Date: December 13, 2019 Customer P.O. Number: Customer Project Number: Job Number: Job Name: Sabey IGW Bldg B - MM Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 7 Variable Air Volume Fan Powered Terminal Units 6 Variable Air Volume Single Duct Terminal Units Submittal Notes: • Contractor to confirm L or R hand configuration prior to order. This is determined as if the supply air is blowing into the direction of your face. Tiffany Rourke Trane 2333 158th Court NE Bellevue, WA 98008 Phone: (425) 586-1211 Cell: Fax: (425) 643-4314 The attached information describes the equipment we propose to fumish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 03 2020 City of Tukwila BUILDING DIVISION MIV)207 nECEIVED CITY OF TUKWILA DEC 18 2019 PERMIT CENTER J:IJOBSI125111757931Sabey 1GW Bldg B - 2nd Floor VAV Box SUB 12-13-19.doc Table Of Contents Product Summary 1 Variable Air Volume Fan Powered Terminal Units (Items Al - A7) Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications c 6 Unit Dimensions f 8 Accessory 12 Field Wiring 14 Variable Air Volume Single Duct Terminal Units (Items B1 - B6) Tag Data 16 Product Data 16 Performance Data 17 Mechanical Specifications 18 Unit Dimensions 19 Tan Dmta-Vmrimb|eAirVmlunnmFonPowmrmd Terminal Units [Qtv:7 Item Tag(s) Qty Description Model Number Al VAV-201 1 VAVFan Powered Terminal Units /FP) VPEF14 A2 VAV-202 1 VAVFan Powered Terminal Units (FP) VPEF08 A3 VAV'203 1 VAVFan Powered Terminal Units (FP) VPEF10 A4 VAV'204 1 VAVFan Powered Terminal Units (FP\ VPEF10 A5 VAV-205 1 VAVFan Powered Terminal Units (FP) VPEF10 AO VAV-208 1 V/\VFan Powered Terminal Units (FP> VPEF10 A7 VAV'2012 1 V/\VFan Powered Terminal Units (FP\ VPEF12 Product Data -Variable Air Volume Fan Powered Terminal Units All Units Parallel with electric heat 1^[20mm] matte faced insulation Flanged connection 277/60/1 motor voltage High efficiency electrically oomutated motor Refer to "Customer Supplied" controls Shafton|y- with controls enclosure Customer provided actuator Left hand controls connection Disconnect switch Power fuse 277volt, 1phase 2stages ofheat ' equal increments 24vmnmercury contactors Electric heater air flow switch 1styear labor warranty -whole unit Item; All Qty: i Tag(s): VAV'201 14°(356mm) 04super quiet fan kilowatt Item: A2 Qty:1 Tag(s): VAV-202 8^(203mm) 03super quiet fan 3.ON|owot Item: A2 Qty:1 Tao(s): VAV'203 10^/254mm\ 03super quiet fan 3.5W|owatt Item: A4.A5 Qty: 2 Tam(s): VAV'204.VAV'205 1O^(25mm) O3super quiet fan 3.0 kilowatt Itemn:A6 Qty:i Tag(s): VAV'206 10^(354mm) 03super quiet fan 2.OkUowott Item: A7 Qty: I Tao(s): VAV'2012 12.(3O5mm) O3super quiet fan 5.0 kilowatt FLD~pumis»odby7rameKS. Inc. dbmnano/ Equipment Submittal Page zura1 saueyuam/Bldg o'mm Performance Data - Variable Air Volume Fan Powered Terminal Units Tags VAV'201 VAV'202 VAV'203 VAV-204 .VAV'205 VAV'206 Design cooling airflow (cfm) 1000 554 1253 910 1155 1074 Min cooling airflow (ofm) 321 112 250 183 231 314 Valve heating airflow (cfm) 321 112 250 183 231 214 Cooling inlet diameter (in) 14.000 8.000 10.000 10.000 10.000 10.000 Cooling inlet velocity /M/min\ 1502 1016 2297 1879 2118 1909 APD @ cooling airflow (in H20) 0.031 0.080 0.057 0.034 0.049 0.044 Fan airflow bfm\ 043 225 502 369 462 431 Downstream 8P (in M20) 0.250 0.250 0.250 0.250 0.250 0.250 Lock downstream GP? Yes Yes Yes Yes `yeo Yee Fan TGP(in H2D) 0.257 0.252 0.255 0.254 0.255 0.255 Y6 of fan range (Y6> 35.00 6.00 36.00 22.00 32.00 28D0 Fan power (hp) 0.500 10.333 0.333 0.333 0.333 0.533 Elevation (t) 0.00 0.00 0.00 0.00 0.00 0.00 Plenum EAT (F\ .� 7O�OO TODO ^ 7O.D0 70.00 70.00 70.00 Primary EOB(F) 64.00 64.00 63.00 64.00 64.00 64.00 Run acoustics? No No No No No No , Operating weightUb> 116.0 112.0 113.8 113.0 113.0 113.0 Max heating fan airflow bfm\ 643 225 602 369 462 431 Minimum fan airflow (cfm) 643 225 502 389 462 431 Unit heating airflow (ofm) 994 337 752 552 693 045 Coil heating capacity (yWBh) 13.60 10.24 11.95 10.24 10.24 6.83 Room heat loss (yWBh) 13.66 10.25 11.69 10.25 10.25 0.84 Room heating nntpnint(F) 68.00 68.00 08.00 68.00 68.00 68.00 Coil EAT (F) 88.00 68.01 67.67 68.01 68.00 08.01 Unit LAT(F) 81.06 96.02 82,32 86.12 81.63 7777 Coil LAT(F) 81.08 96.02 82.32 85.12 81.63 77.77 Full load amps (A) 17.94 18.23 15.04 13.23 13.23 0.62 Min circuit ompncity(A) 22.43 10.54 18.79 18.54 10.54 12.03 Max nvernurrentprotection (A) 25.00 20.00 20.00 20.00 20.00 15.00 Electric heater kVV (kW) 4.00 3.00 3.50 3.00 3.00 2.08 flD=Fumw»edoy7ramoKS.Inc, uuanano/ Equipment Submittal Page *oro Tags VAV-2012 Design cooling airflow (cfm) 1674 Min cooling airflow (cfm) 334 Valve heating airflow kcfm\ 334 Cooling inlet diameter (in) 13.000 Cooling inlet velocity 0t/nin\ 2131 APO 8B cooling airflow (in H20) 0.032 Fan airflow kcfm> 670 Downstream SP(in H3O> 0.250 Lock downstream 8P? You Fan TSP(in H2C}} 0.358 Y6offan range (9Q 55.00 Fan power (hp) 0.333 Bevadon(fd 0.00 Plenum EAT (F) 70.00 PhmaryEDB (F) 63.90 Run acoustics? No Operating weight (lb) 114.0 Max heating fan airflow (cfm) 670 Minimum fan oirOow(cfm) 670 Unit heating airflow (cfm) 1004 Coil heating capacity (yNBh) 17.08 Room heat loss (NBh) 17.04 Room heating netpnint(F) 68.00 , Coil EAT (F) 87.87 Unit LAT(F) 83.65 Coil LAT(F) 83.65 Full load amps (A) 20/45 Min circuit ampaokyh4\ 25.56 Max nvercunentprotection (A) 30.00 .Electric heater kW (kW) 5.00 ^ rlD=Fxnis»odbyTravoL/S. Inc. dbanano/ equipment Submittal Page nm,21 aauey|oVvBldg B'MM December 13.oU1S YNauham|uml Specifications ' Variable Air Volume Fan Powered Terminal Units NOTICE Due to regulatory compliance, mercury contactor electric heat control is not permitted in several localities including but not limited tmthe following Interstate Mercury Education and Reduction Clearinghouse (I&VERC) state members: Connecticut, Louisiana, Maine, Massachusetts, Minnesota, New Hampshire, New York, Rhode Island and Vermont. &naddition the following states do not permit mercury contactor electric heat control based omstate legislation: California, Illinois, Maryland and Wisconsin. Check local regulations prior to se/ectimgVnstailing mercury contactor electric heat control. General Unit Information Casing - The unit casing is 22 gauge galvanized steel. Outlet duct connection is flanged. Total metal encapsulation of all insulation edges. Hanger Brackets provided. Side access is provided. Filter -Afilter io provided on the plenum |n|oL Agency Listing - UL and Canadian UL listed as environmental air terminal unit. ULControl #9NU5. All Tnaneterminal units are AHR|8MO-88certified. General Unit Clearance Leave a minimum of 36" on control box side of unitfor adequate service access. Allow at least 12" on remaining sides for unit clearance. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. Electrical Installation Information For electrical connections, consult field wiring section & equipment IOM. IMPORTANT. Field Wirinct Most fan -powered VAV terminal units with electric reheat require a neutral connection from building power, however, some configurations donot. In order to prevent a building wiring issue once the boxes are installed, the wiring diagrams and field wiring installation for each unit MUST be checked to determine whether the neutral is required or not required. 1~[25.4mnm]Matte - Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1", 1.5|b/cu.fLcomposite density glass fiber with high density facing. The insulation iaULlisted and meets NFPA-9UAand UL181standards. All insulation options will meet the 25/5Osmoke developed and flame spread rating (per ASTK4 E84and UL723and CAN/ULC S102-M88) Meets NFPA- 90B. No exposed edges of insulation [complete metal encapsulation]. The insulation R-value is 3.85. All cut edges of insulation are completely encapsulated in metal to prevent erosion. 1203SQ Air Valve/Fan Combination Size (Parm||w|) 12" Inlet designed for up to 2000.0 cfm. Fan is 1100.0 cfm for Stid Motor and 1085.0 cfm for ECM Motor. Air Valvm& Fan Description (Para|leU The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring airflow within +/- 5% of unit cataloged airflow. Also provided with each unit is a calibration chart indicating airflow versus flow sensor pressure differential. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected through a cast zinc stub axle and shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. Air valve leakage <196o14^ 0803SQ Air Valve/Fan Combination Size (PsraUm|) 8" Inlet designed for up to 900.0 cfm. Fan is 1100.0 cfm for Std Motor and 1085.0 cfm for ECM Motor. 1003SQ Air Valve/Fan Combination Size (Parw|hm|) 10" Inlet designed for up to 1400.0 cfm. Fan is 1100.0 cfm for Std Motor and 1085.0 cfm for EGM Motor.. 1404SQ Air Valve/Fan Combination Size( 14" Inlet designed for up to 3000.0 cfm. Fan is 1350.0 cfm for Std Motor and 1510.0 cfm for ECM Motor. ECM Motor (ECM) The ECM motor is a single speed brushless DC motor with integrated controller. Motor and fan assembly are isolated from terminal unit. Speed adjustment is done either with an ECM interface board with manual speed adjustment or done pLo=Furnished byTramoUG'Inc. dbanane/ Equipment Submittal Page oof21 Sabey IGW Bldg B - MM directly with Trane UC210 or UC400 DDC Controllers. December 13, 2019 Fuse Any electric heat unit with a calculated MCA greater or equal to 30 will have a fan fuse provided. Electric Heat Coil Factory provided and mounted. Resistance open -type heater, a disc -type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel -chromium. The heater terminal box is provided with knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. All fan -powered units with electric reheat are single -point power connections. Transformer The 50 VA transformer is factory mounted in the fan control box to provide 24 VAC for controls. Mercury Contactor An electric heater 24 volt contact for use with Direct Digital Control (D.D.C.) or Analog Electronic VAV Controls. Due to regulatory compliance issues, mercury contactors may not be used in several localities. Check local regulations before using mercury electric heater control. Power Disconnect Switch (for VSEF & VPEF) A factory provided interlocking door disconnect switch located on the electric heater control panel. Airflow Switch An air pressure device designed to disable the heater when the unit fan is off. Power Fuse Fuses provided on all energized lines of incoming power to interrupt circuit overcurrent conditions. Flanged Connection A rectangular opening on the unit discharge to accept a 90 degree flanged duct work connection. Controls Option ENCL- Shaft Only This control option is for field mounting of 24 volt actuator and controls on the units external shaft. ENCL is only for use with DDC and Analog Electronic controls. Controls Transformer The 50 VA transformer is factory mounted in the fan control box to provide 24 VAC for customer supplied controls. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 7 of 21 Int.11art 1,, rithnrc Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Fan Powered Terminal Units ' Item: Al Qty: 1 Tag(s): VAV-201 December 13, 2019 Unit Size VPEF1404SQ Nominal 14" Dia. x 4" Depth Valve Size & Depth Nominal 04SQ Fan Fan Size Filter Size 16" x 20" x 1" (OTY 1) TOP VIEW 5" 161/2" SIOHINOO n 22" z a co 0 x AIRFLOW 51 32 112" HEATER 16" u AIRFLOW DISCHARGE OUTLET 40" 6" PANEL SLIDES FOR MOTOR ACCESS d 20" DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. Extemal insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first runout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. 10. A4 wire power supply required for 480\3 & 575\3 single point connection units. Approximate Dry Weight 138.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 8 of 21 Inetollorl by nthorc 20" DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. Extemal insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first runout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. 10. A4 wire power supply required for 480\3 & 575\3 single point connection units. Approximate Dry Weight 138.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 8 of 21 Inetollorl by nthorc Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Fan Powered Terminal Units Item: A2 Qty: 1 Tag(s): VAV-202 December 13, 2019 Unit Size VPEF0803SQ Nominal 8" Dia. x 4" Depth Valve Size & Depth Nominal 03SQ Fan Fan Size Filter Size 16" x 20" x 1" (QTY 1) TOP VIEW 16 1/2" 5" — 16" AIRFLOW DISCHARGE OUTLET 40' PANEL SLIDES FOR MOTOR ACCESS 01 u 20" DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. Extemal insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first ninout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. 10. A4 wire power supply required for 480\3 & 575 \ 3 single point connection units. Approximate Dry Weight 96.0 Ib Weights reflected may vary ±-5.0 Ib based upon options selected. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 9 of 21 Inctn11.4 ht, tlfh.rc 20" DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. Extemal insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first ninout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. 10. A4 wire power supply required for 480\3 & 575 \ 3 single point connection units. Approximate Dry Weight 96.0 Ib Weights reflected may vary ±-5.0 Ib based upon options selected. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 9 of 21 Inctn11.4 ht, tlfh.rc Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Fan Powered Terminal Units Item: A3 - A6 Qty: 4 Tag(s): VAV-203, VAV-204, VAV-205, VAV-206 December 13, 2019 Unit Size VPEF1003SQ Nominal 10" Dia. x 4" Depth Valve Size & Depth Nominal 03SQ Fan Fan Size Filter Size 16" x 20" x 1" (QTY 1) TOP VIEW 5" A 16 1/2" sloaLNo0 22" xo81VNMwa31 n AIRFLOW HEATER U 16" AIRFLOW DISCHARGE OUTLET 20" 40" 6" 32 1 /2" PANEL SLIDES FOR MOTOR ACCESS DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. External insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first runout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance, 10. A 4 wire power supply required for 480\3 & 575\3 single point connection units. Approximate Dry Weight 96.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 10 of 21 Inc/nllord by (Whore Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Fan Powered Terminal Units Item: A7 Qty: 1 Tag(s): VAV-2012 December 13, 2019 Unit Size VPEF1203SQ Nominal 12" Dia. x 4" Depth Valve Size & Depth Nominal 03SQ Fan Fan Size Filter Size 16" x 20" x 1" (QTY 1) TOP VIEW 5" 16" AIRFLOW DISCHARGE OUTLET 40" PANEL SLIDES FOR MOTOR ACCESS u DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. External insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first runout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. 10. A4 wire power supply required for 480 13 & 575 \3 single point connection units. Approximate Dry Weight 96.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal InRtallnri hv nthprc Page 11 of 21 DISCHARGE VIEW NOTES: 1. Allow a minimum 6" plenum inlet clearance for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 3. For Motor access, remove bottom screws on hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger bracket location. 5. Air valve centered between top & bottom panel. 6. Heating coil un-insulated. External insulation may be field supplied and installed as required. 7. All high & low voltage controls have same -side NEC jumpback clearance. 8. Allow 48" of straight duct downstream of unit before first runout and inside of the duct should be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. 10. A4 wire power supply required for 480 13 & 575 \3 single point connection units. Approximate Dry Weight 96.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal InRtallnri hv nthprc Page 11 of 21 Sabey IGW Bldg B - MM Accessory - Variable Air Volume Fan Powered Terminal Units Item: Al Qty: 1 Tag(s): VAV-201 December 13, 2019 Notes: 1. When attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance. 2. ECMs (Electrically Commutated Motors) are ideal for systems seeking maximum motor efficiency. VPCF and VPEF maximum Minimum 1-row coil maximum -•-•-•-•-•-• 2-row coil maximum Pa In. wg 125 0.50 100 0.40 m 4 ��nj yyV 75 0.30 m d o) t cs cs p 50 0.20 25 0.10 200 94 400 189 600 283 VPxF 04SQ---ECM 800 1000 378 472 Airflow 1200 566 1400 661 1600 Cfm 755 Us FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 12 of 21 fncf !kd by nthorc Sabey IGW Bldg B - MM Accessory - Variable Air Volume Fan Powered Terminal Units • Item: A2 - A7 Qty: 6 Tag(s): VAV-202, VAV-203, VAV-204, VAV-205, VAV-206, VAV-2012 December 13, 2019 Notes: 1. When attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance. 2. ECMs (Electrically Commutated Motors) are ideal for systems seeking maximum motor efficiency. VPCF and VPEF maximum Minimum 1-row coil maximum 2-row coil maximum Discharge Static Pressure Pa In. wg 125 0.50 00 0.40 75 0, 0 50 a 0 VPxF 03S ECM 1 A t. t 25 0.10 100 200 300 400 500 600 700 800 900 1000 1100 Cim 47 94 142 189 236 283 330 378 425 472 519 l_ts Airflow FLD = Furnished by Trane U.S. inc. dba Trane / Equipment Submittal Page 13 of 21 Inctallari ntharc Sabey IGW Bldg B - MM December 13, 2019 Field Wiring - Variable Air Volume Fan Powered Terminal Units " Item: Al - A7 Qty: 7 Tag(s): VAV-201, VAV-202, VAV-203, VAV-204, VAV-205, VAV-206, VAV-2012 277 Volt, 1 Phase L1 I I I I I I I I Heater Control Wiring A\ WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH /\ CAUTION USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. Customer Notes: Factory installed. — — — — Optional or installed by others. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 14 of 21 Inctailorl ht, (-Whore Sabey IGW Bldg B - MM December 13, 2019 Field.Wiring - Variable Air Volume Fan Powered Terminal Units Item: Al - A7 Qty: 7 Tag(s): VAV-201, VAV-202, VAV-203, VAV-204, VAV-205, VAV-206, VAV-2012 FROM HEATER TERMINAL BOX W C/ /DISCONNECT K NOTES. FACTORY WIRING FIELD WIRING ^--OPTIONAL OR ALTERNATE WIRtN6 2 ALLFtELDW1RtNG MUST BE IN ACCORDANCE WITH THE /� NATIONAL ELECTRIC CODE {NEC), STATE AND LOCAL REQUIREMENTS_ C POWER FACTOR CORRECTION C0000 LOCATED IN CONTROL 80X. \\� DISCONNECT SWITCH, FUSE AND MOTOR SPEED CONTROL ACTUATORS ARE LOCATED EXTERNAL TO CONTROL BOX. ClCLASS 2 CONTROLS TRANSFORMER P0OVI0E0 IN ALL UNITS. EL USE O TO VAV CONTROLLER V ECM OTO K Y TRANSf0RME W BK 0 0 CHOKE FAN CONTROL ON/OFF 24VAC POWER ELECTRIC HEATER CONTROL V (GND) EL (24VAC) 1ST STAGE HEAT ORN COM OPTIONAL BR C STAGED ELECTRIC j HEATER :ED 2ND STAGE HEAT 3R0 STAGE NEAT HEATER CONTRACTORS ARE 24 VAC: 12.VA MAX/COIL (MERCURY CONTACTORS). 10VA MA)NCOIL (MAGNETIC CONTACTORS). HK tHT OK RN EO NA L BLOCK TO ECM MOTOR FAN CFM CAN BE ADJUSTED FROM ITS MIN CFM TO ITS MAX CFM VIA THE ECM CONTROL BOARD FAN ADJUST. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 15 of 21 fncfallarl by flfharc Sabey IGW Bldg B - MM December 13, 2019 TagData - Variable Air Volume Sin le Duct Terminal Units Qt : 6 Item Tag(s) Qty Description Model Number B1 VAV-207 1 Variable Air Volume Single Duct Termina VCCF05 B2 VAV-208 1 Variable Air Volume Single Duct Termina VCCF08 B3 VAV-209 1 Variable Air Volume Single Duct Termina VCCF06 B4 VAV-210 1 Variable Air Volume Single Duct Termina VCCF08 B5 VAV-211 1 Variable Air Volume Single Duct Termina VCCF08 B6 VAV-213 1 Variable Air Volume Single Duct Termina VCCF05 Product Data - Variable Air Volume Single Duct Terminal Units All Units Single duct cooling only terminal Matte faced insulation - 1" (25 mm) Refer to "Customer Supplied" controls Shaft only - with control enclosure Left hand &/or same side connection (control &/or hot water coil) Disconnect switch 1st year labor warranty whole unit Item: B1, B6 Qty: 2 Tag(s): VAV-207, VAV-213 5" inlet size, 350 cfm (127mm inlet, 165 Vs) Item: B2, B4, B5 Qty: 3 Tag(s): VAV-208, VAV-210, VAV-211 8" inlet size, 900 cfm (203mm inlet, 425 Us) Item: B3 Qty: 1 Tag(s): VAV-209 6" inlet size, 500 cfm (152mm inlet, 236 Vs) FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 16 of 21 Inctallarl hv nth,- . Performance Data ~Variable Air Volume Single Duct Terminal Units Tags VAV'207 VAV-208 VAV-209 VAV^210 VAV'211 VAV'213 Design cooling airflow (cfm) 240 571 394 574 545 252 Min cooling airflow /ofm\ 48 115 78 115 109 50 Valve heating airflow (nfm) 48 115 78 115 109 50 Cooling inlet diameter 5^ 81. G^ B" 8^ 5" Cooling inlet velocity 8t/min\ 1700 1030 2007 1044 1581 1848 APO KD000{in" airOuw(in H20) 0.810 0.040 0.140 0.040 0.040 0,010 Elevation (ft) 0.00 0.00 0.00 0.00 0.00 0.00 Operating weight Ub\ 16.0 16.0 10.0 16.0 16.0 �10.0 Run acoustics? No No No No No No Room heating s*tpnint(F) 88.00 68.00 58.00 68.00 88.00 68D0 Primary EOB(F) 55.00 55.00 55.00 55.00 55.00 55.00 Unit LAT(F) 55.00 55.00 55.00 55D0 55.00 55.00 Electric heat kW (kW) 0.00 0.00 0.00 0D0 0.00 0.00 FLD =pummood by7rmeuS.Inc. ma,nane/ Equipment Submittal Page /rorz, aauwylGWBldg B'Mw Mechanical Specifications ' Variable Air Volume Single Duct Terminal Units December 13,281S General Unit Information The unit casing iscomprised of22gougega|veniaedstee|.OudetcunnechoniasUponddrive. Agency Listing - The unit is UL and Canadian UL listed as a room air terminal unit, UL Control # 91465. All Trane terminal units are AHR|8M0'S8certified. General Unit Clearance Allow adequate clearance oncontrol box side ofunit tomeet NEC. Aminimum cfone and one half duct diameters oY straight duct work, upstream of the air inlet connection, must be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. Allow access to the bottom of unit if Optional Bottom Access Door ioselected. I "Matte 'Faced Insulation The interior surface of the unit casing is acoustically and thermallylined with 1" 1.00 lb.cu. ft. [16.0 kg./cu. m.] composite density glass fiber with 4Dlb. cu. ft. [G4ko./cu.m]high density facing. The insulation iaULlisted and meets NFPA'90A and UL181 standards. The insulation R-value is 3,85. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve Size ~85 Air Valve is 350,0 cfm 5" inlet. Air Valve Size -0@ Air Valve Size '08 Air Valve is 900.0 cfm 8" inlet. Air Valve Round The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring within +/- 5% of unit cataloged airflow. An airflow versus pressure differential calibration chart is provided. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22gauge galvanized steel disks. The damper blade assembly ioconnected through mcast zinc stub axle and shaft supported byself lubricating bearings. The shaft iacast with odamper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. At 4.0" w.g. air valve leakage does not exceed 1% of cataloged o|dlovv. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. This is a standard option on all VAVs|ng|e duct terminal units. Toggle Disconnect Switch (for VCCF& A switch, installed in a unit mounted controls enclosure, which breaks both power legs within the control box. FLo=Furnished by Trane U.sInc. dbmnnne/ Equipment Submittal Page /oof 21 Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Single Duct Terminal Units Item: B1, B6 Qty: 2 Tag(s): VAV-207, VAV-213 December 13, 2019 14 CONTROL BOX 5 1/2" C., 2 3/4* AIR VALVE 6 5/6" 5 SLIP & DRIVE CONNECTION TOP VIEW 9 AIR FLOW 11 /2" 11 1/2" 10" BACK VIEW 8" 9 1/2" Customer Notes 1. Air Inlet is centered in unit front panel. 2. Slip & Drive discharge outlet standard. 3. Minimum of 1.5 duct diameters of straight duct required at inlet for proper flow reading. 4. Allow 36" on control side for servicing. 5. Unil is field -convertible from a left-hand connection (shown) to a right-hand by rotating unit, Approximate Dry Weight 16.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 19 of 21 Incf.11.,1 kir inthc.rc• Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Single Duct Terminal Units Item: B2, B4, B5 Qty: 3 Tag(s): VAV-208, VAV-210, VAV-211 December 13, 2019 5 1/2" 2 1/4" < 5 1/2"--C> CONTROL BOX AIR VALVE 14 5/8" 50" — SLIP & DRIVE CONNECTION TOP VIEW AIR FLOW 121/2' 11" r- 9 1/4" BACK VIEW 10" 11 /2" Customer Notes 1. Air Inlet is centered in unit front panel. 2. Slip & Drive discharge outlet standard. 3. Minimum of 1.5 duct diameters of straight duct required at inlet for proper flow reading. 4. Allow 36" on control side for servicing. 5. Unit is field -convertible from a left-hand connection (shown) to a right-hand by rotating unit. Approximate Dry Weight 16.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Fumished by Trane U.S. Inc. dba Trane / Inetallorl hti ntharc Equipment Submittal Page 20 of 21 Sabey IGW Bldg B - MM Unit Dimensions - Variable Air Volume Single Duct Terminal Units Item: B3 Qty: 1 Tag(s): VAV-209 December 13, 2019 51/2- SUP & DRIVE CONNECTION TOP VIEW BACK VIEW 2 3/4" AIR VALVE AIR FLOW V 11 (2' Customer Notes 1. Air Inlet is centered in unit front panel. 2. Slip & Drive discharge outlet standard. 3. Minimum of 1.5 duct diameters of straight duct required at inlet for proper tow reading. 4. Mow 36" on control side for servicing. 5. Unit is field -convertible from a left-hand connection (shown) to a right-hand by rotating unit. Approximate Dry Weight 16.0 Ib Weights reflected may vary ±5.0 Ib based upon options selected. FLD = Furnished by Trane U. S. inc. dba Trane / Inctolliarl kat nth, Equipment Submittal Page 2/ of 21 TRAIN Submittal Prepared For: M. Contractor: MacDonald -Miller Facility Solution Sold To: Date: December 12, 2019 Customer P.O. Number: Customer Project Number: Job Number: Job Name: Sabey IGW Bldg 8 - MM FILE Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Packaged Rooftop, Cooling / Heating Units Tiffany Rourke Trane 2333 158th Court NE Bellevue, WA 98008 Phone: (425) 586-1211 Cell: Fax: (425) 643-4314 The attached information describes the equipment we propose to fumish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2020 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 8 2019 PERMIT CENTER t119 020'7 J:IJOBS1125111757914ISabey IGW Bldg B - RTU SUB 12-12-19.doc ` ' Table Of Contents Product Summary I Packaged Rooftop, Cooling /Heating Units (item Al) TagData-- ... '--------........ '--.---.J PerformanceData ... ------....... --- .... ----....... —......... ---------------......... 4 MechanicalSpecifications ................... —................ .---...................... —.................. .................. - 6 Unit Dimensions 9 FanCurve ............... ....... -------......... ---....... ......... ................... ........... ---- ........ 11 Weight, Clearance & Rigging Diagram 12 Accessory 13 Field Wiring 15 , Tag Data - Packaged Rooftop, Cooling / Heating Units (Qty: 1 Item Tag(s) Qty Description Model Number Al RTU-1 1 40Ton PackalsedCommeroia| Rooftop YCO480 Item: Al Qty:1 Tao(s): RTU-1 DXCooling, natural gas heat DnvvnOowsupply and unflowreturn 4Uton GOHertz 46OVolt 6OHertz 3Phase Low gas heat capacity 1OD%Power exhaust w/ultra low leak dmper& Stmtbracbui|ding pressure control 2"K4EFlV8High efficiency, throwaway filters 15hpsupply motor 0-1UOY6Economizer, dry bulb control wyultra low leak (]Adamper VAV/OTC\with supply VFD&motor shaft grounding Hinged service access doors 8ACnetcommunication interface module High fault SCCRw/disconnect switch eShage.High efficiency unit LPConversion kit (Hd) Year 1 Labor Warranty Whole Unit pLo~Furnished uynanouaInc. mmnano/ Equipment Submittal Page 3or/a SaboyIGWBldg B'MM Performance Data - Packaged Rooftop, Cooling / Heating Units Tags RTU'1 Supply airflow (nfm) 15000 Elevotion(fd 0.00 Cooling entering DB(F) 80.00 Cooling entering VVB(F) 67.00 AmbiendOB (F) 95.00 Cooing leaving unit OB/F\ 59.75 Cooling leaving unit VVB(F) 57.50 Cooling leaving coil OB(F) 5710 Cooling leaving coil VVB(F) 56.44 Gross total capacity /K4Bh> 493.77 Gross sensible capacity UNBh\ 378.85 Gross latent capacity UNBh> 116,92 Net total capacity (N4Bh) 453.00 Net sensible capacity (01Bh) 335.07 Net sensible heat ratio y&\ 0.74 Input hb]capacity (Ml3h) 400.00 Output hbgcapacity (yW13h) 320.00 Heating EAT (F) 70.0X0 Heating LAT(F) 90.10 Heating delta TQF\ 20.10 ESP (in H2O) 2.000 Total static pressure (in H2{B 3,028 Actual Supply Motor BHP (hp) 14.324 Supply Motor Power (kVV)(rpm) 700 Indoor motor power (kVV) 10.70 Outdoor motor power (kVV) 0.02 Compressor power (kVV) 33.14 System power (kW) 49.68 EER @AHR1(EER) 11.0 |EER@AHR|(EER) 147 Minimum circuit ampacity (A) 103.25 Maximum overcurrent protection (A) 125.00 Minimum disconnect switch size (A) 112.00 Compressor RLA(A) 14.10 Compressor RLA(A) 23.00 Compressor 3RLA(A) 23.00 Supply fan FLA(A) 18.00 Condenser fan FLA(A) 3.50 Condenser fan count (Eoch) 4.00 Exhaust fan FLA(A) 2.70 Exhaust fan count (Each) - 2.00 Electric heater FLAA\\ 0.00 Crankcase heater FL/\A\> 0.00 Unit eatoperating weight (lb) 6086.0 Discharge duct -G3Hz(dB) 89 Discharge duct -125Hz(d8) 91 Discharge duct '25UHz(dB) 83 Discharge duct -5U0Hz(d8) 83 Dimnhargaduot- 1 kHz/dB) 77 Discharge duct -2kHz (dB) 75 Discharge duct '4kHz (dB) 71 Discharge duct -8kHz (dB) GG Return duct -G3 Hz kjB) 91 Return duct -125Hz(d6) 90 Return duct -25UHz(dB) RS FLD=Furnished byTran K�Inc. mmTrame/ squipmentaubmittal Page *or/5 Sabey IGW Bldg B - MM Tags December 12, 2019 RTU-1 Return duct - 500 Hz (dB) 82 Return duct - 1 kHz (dB) Return duct - 2 kHz (dB) Return duct - 4 kHz (dB) Return duct - 8 kHz (dB) Outdoor - 63 Hz (dB) 77 75 74 75 104 Outdoor - 125 Hz (dB) 97 Outdoor - 250 Hz (dB) Outdoor - 500 Hz (dB) Outdoor - 1 kHz (dB) 96 97 95 Outdoor - 2 kHz (dB) 93 Outdoor - 4 kHz (dB) 88 Outdoor - 8 kHz (dB) 79 HFCF-410A refrigerant charge - circuit 1 (lb) EDB in HGRH (F) 61.0 73.00 EWB in HGRH (F) 64.00 Ambient in HGRH (F) Reheat setpoint (F) 75.00 70.00 FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 5 of 15 Inctallprl by r}thprc Sabey lGW Bldg e'MM 'y0muhmniuml Specifications ' Packaged Rooftop, Cooling /Heating Units General R-410A The units shall be downflow, horizontal, or mixed airflow. The operating range shall be between 115'F and O'F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with AHRI testing procedures. All units oho|( be factory assembled, internally wired, fully charged with R'410A refrigerant and 100f6 run tested to check cooling operation, fan and blower rotation and control sequence before leaving the factory. Wiring internal to the unit shall be numbered for simplified identification. Units shall be cULus listed. Compressors R410A The 3-D Scroll shall provide a completely enclosed compressor chamber with optimized scroll profiles which leads to increased efficiency, The 3-D Scroll shall include a direct -drive, 3600 rpm, suction gas cooled hermetic motor. The compressor shall include a centrifugal oil pump, scroll tips seals, internal heat shield that lowers the heat transfer from discharge and suction gas, oil level sight glass and oil charge valve. Some compressor models shall also provide a dip tube that allows for oil draining, in addition to a low leakage internal discharge check valve to help prevent refrigerant migration. Each compressor shall have a crankcase heater installed, properly sized to minimize the amount ofliquid refrigerant present inthe oil sump during off cycles. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Cabinet surface shall be tested 672 hours insalt spray incompliance with A8TK813117,All components shall bemounted inoweather resistant steel cabinet with a painted exterior. Where top cover seams exist, they shall be double hemmed and gasket sealed to prevent water leakage. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have handles and shall be removable while providing a water and air tight seal. Control box access shall be hinged. The indoor air section shall be completely insulated with fire resistant, permanent, odorless, foil faced glass fiber material. The base ofthe unit shall have provisions for crane lifting. Hinged Service Access Filter access panel and supply fan access panel shall be hinged for ease of unit service. High Efficiency Unit This option shall provide five stages of mechanical cooling with the ability to be at or below 25% compressor displacement at stage one. Service valves shall also be provided factory installed and include suction and discharge 3'wmyshutoff valves. Phase and Voltage Monitor Standard on all Voyager Commercial units. Shall protects 3-phase equipment from phase loss, phase reversal, and low voltage. Any fault condition shall send the unit into an auto stop condition. cULus approved, Refrigerant Circuits Each refrigerant circuit shall have independent thermostatic expansion devices, service pressure ports and refrigerant line filter driers factory -installed as standard. An area shall be provided for replacement suction line driers. Outdoor Fans The outdoor fan shall be direct -drive statically and dynamically balanced, draw through in the vertical discharge position. The fan motors shall be permanently lubricated and have built-in thermal overload protection. Evaporator and Condenser Coils -R41OA Condenser coils shall have all Aluminum yWinroohanne|coils. Evaporator coils shall bainternally finned Copper tubes mechanically bonded to high performance Aluminum plate fins. All coils shall be leak tested at the factory toensure pressure integrity. The evaporator coil is pressure tested to 450 psig and the condenser coil at 650 psig. All dual circuit evaporator coils shall be of intermingled configuration. Sloped condensate drain pans are standard. H2Stage Gas Heat The heating section shall have a drum and tube heat exchanger(s) design with primary and secondary surfaces of corrosion resistant aluminized steel or optional stainless steel. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a regulated gas valve shall be used that requires blower operation to initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat uxohonger(o)4Sseconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall belocked out until manually reset at the thermostat. Two stage gas heat units shall ba suitable for use with natural gas or propane (field installed kit). Gas heat units comply with California requirements for |ovv NOx emissions. FLD=Furnished uyTran U.S. Inc. dbanan/ Equipment Submittal Page so,/5 aauey|GmBldg o'Mm ovcember12, 2019 'Indoor Fan, 60 Hz Supply Motor Unit will have belt driven, forward curve, centrifugal fans with fixed motor sheaves. The supply fan motors will be circuit breaker protected. All OOHzsupply fan motors meet the Energy Independence and Security Act of20OS(BSA). Variable Frequency Drive Unit shall include factory -installed and tested variable frequency drive[s] (VFD) to provide motor speed modulation. The VFDshall receive m0'10VDCspeed signal from the unit controller. The drive will respond bothe signal byaccelerating or decelerating to maintain the controlling set point (duct static, space pressure, etc). VFO shall also include the following features: 1. Designed, constructed, and tested inaccordance with NEMA|CS.NFPA.and |ECstandards and housed ino plastic IP20 enclosure. 2. DClink reactors onboth the positive and negative rails ofthe DCbus equal to396impedance tominimize power line harmonics. 3. Full rated output current continuously -11O%ofrated current for 0Oseconds and 160Y6ofrated current for upUo 0.5 second while starting. 4. Isolation between the Ohve'spower circuitry and control circuitry Unensure operator safety and Voprotect connected electronic control equipment from damage caused by voltage spikes, current surges, and ground loop currents. 5. Audible noise reduction through automatic adjustment of the carrier frequency and frequency avoidance. G� Rated et40C with ostandard operating range of'10ho6UC(14Uo124F)ambient temperatures and Uho95Y6 relative humidity T' Self -diagnostics and motor protections such as: cUlLus listed overload, phase loss, and internal thermal overload. 8. Off/Stop and Auto/Start selector switches to start and stop the AC Drive and determine the speed reference. a. On units with bypass, an AC Drive/Off/Bypass hand selector switch shall be provided in the unit control box b. |nDRIVE mode speed reference shall beprovided byaO-1OVOCanalog input S. A keypad interface which shall be programmable by language and feature multiple lines for easy reading 10. Controlled and/or accessible points such as AC Drive Start/Stop, speed reference, and fault diagnostics. 11. Meter points such as motor power in HP, motor power in kW, motor kW-hr, motor current, motor voltage,hours run, DClink voltage, thermal load onmotor, Thermal load unAC Drive and Heatsinktempenotura. 12. Troubleshooting features such as: a. AC Drive memory storage ofthe last 1Ofaults and related operational data b. Four simultaneous displays: frequency nrspeed, run time, output amps and output power o. Keypad which shall display: Reference Signal Value, Output Frequency in Hz or percent, Output Amps, Motor HP, Motor kW, kW 13. Coated circuit boards for protection against corrosive environments 14. Field readable BACnetpoints to allow for communication ofetmuto. aetpuints and diagnostics hothe BAS. Motor Shaft Grounding Ring Motors shall have internal bearing protection for use withVFDs to provide a conductive discharge path away from the motor bearings to ground, Bearing Protection Rings shall be circumferential rings with conductive micro fibers which provide the path of least resistance and dramatically extend motor life. Modulating 100 Percent Exhaust Fan with Statitrac Control Option A differential pressure control system, (Statitrac), shall use a differential pressure transducer to compare indoor building pressure to outdoor ambient atmospheric pressure and shall turn the exhaust fans on and off and modulate the FLo=Furnished uynaneuo'Inc. manane/ Equipment Submittal Page ro//5 Sabpy.u»m/Bldg s'MM December 1z.eO1y 'barometric exhaust dampers tocontrol the building pressure to within the adjustable, specified dead band that shall be adjustable at the RTVM board. Ultra Low Leak Exhaust The exhaust damper shall be provided with airfoil blades and independent direct drive actuator.Damper shall have a leakage rate of 3 CFM/sq-ft at 1.0 in WC pressure differential (AMCA Class 1A). Damper shall have a functional life of 60.O00opening & closing cycles and have o5'yearwarranty. [Note: Based ontesting completed in accordance with AK4CAStandard 500O] 2~High EfficiencyFllters-yMERV8 2" High Efficiency MERV 8 filters will be standard. Economizer with Dry Bulb Control An economizer shall be factory installed. The assembly shall include: 0 -100 percent fully modulating dampers, minimum position setting, preset linkage, wiring harness, and fixed dry bulb control. Ultra Low Leak Economizer The return air and fresh air dampers shall be provided with airfoil blades and independent direct drive actuators. Dampers shall have aleakage rate of 3 CFM/sq-ft at 1.0 in WC pressure differential (AMCA Class 1 A). Dampers shall have a functional life of 60,000 opening & closing cycles and have a 5-year warranty, [Note:Based nntesting completed inaccordance with AK4CAStandard 500O] Controls Unit shall be completely factory wired with necessary controls and terminal block for power wiring. Units shall provide an external location for mounting fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains aoounabm temperature contno|, minimizes drift from set point and provides better building comfod. Fle|iaTe| controls shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. Unit Interrupt Rating (High Fault Short Circuit Current Rating-SCCR) An optional 65,000 Amp rating (480V) and 25,000 Amp rating (60OV) shall be applied to the unit enclosure using a non -fused circuit breaker for disconnect switch purposes. Fan motors, compressors, and electric heat circuits shall be included with protective devices that will provide the elevated level of fault protection. The unit shall be marked with approved oULummarkings and will adhere tocULusregulations. BACnet Communications The BACnet communications interface shall allow the unit to communicate directly with a generic open protocol BACnet MS/TP Network Building Automation System Controls. 0PConversion Kit Field installed conversion kit shall provide orifice(s) for simplified conversion to liquefied propane gas. No change of gas valve shall barequired. Certified AHRIPerforrnance Packaged Rooftop units cooling, heating capacities and efficiencies are rated within the scope of the Air -Conditioning, Heating & Refrigeration Institute (AHRI) Certification Program and display the AHRI Certified@ mark as a visual confirmation of conformance to the certification sections of AHRI Standard 340-360 (I-P) and ANSIZ21.47 and 10 CFR Part 431 pertaining to Commercial Warm Air Furnaces.The applications in this catalog specifically excluded from the AHR|certification program are: -Ventilation modes -Heat Recovery FL�»=Furnished urnanouS.Inc. manan°/ Equipment Submittal Page uur/a Installed bv Others Sabey IGW Bldg B - MM Unit Dimensions - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 SEE NOTE 2 1 1/4" FEMALE PVC PIPE SEE NOTE 2 7 1 /16"—=- 90 5/8" GAS INLET —31 1/16" 7 9/16" 53 9/16" 232 3/8" CUSTOMER CONNECTION POINT 54 1/8" 232 3/4" NOTES: 1. SEE ROOFCURB DRAWING FOR DETAILS ON FIELD DUCT FITUP AND CONNECTIONS 2. SEE DETAIL HOOD DRAWING FOR HORIZONTAL / DOWNFLOW UNITS FOR ADDITIONAL DIMENSION AND LOCATION. 3. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 90 1/16" 77" 7 1/8" 75 13/16" r RETURN 70 15/16" L SUPPLY PLAN VIEW DOWNFLOW SUPPLY AND UPFLOW RETURN CONFIGURATION DIMENSIONAL DRAWING 3 1/4" FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 9 of 15 tr,er.uarr h / ()hare Babe)! IGW Bldg B - MM • Unit Dimensions - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 ELECTRICAL / GENERAL DATA UNIT Model (Tonnage) YCD480 (40.0) Operating voltage range: 414 - 506 Primary voltage: 460 Hertz: 60 Phase: 3 EER / IEER: 11.0 EER/14.7 EER HEATING - PERFORMANCE Heat: Low Heating Input (Btu/h): 400,000 First Stage (Btu/h): 300,000 Heating Output (Btu/h): 324,000 First Stage (Btu/h): 243,000 No Burners: 1 No. Stages / rum Down Rate: 2 Gas Supply Pressure (in w.c.) Natural or LP: 2.5/14.0 Gas Connection Pipe Size: 3/4" COMPRESSOR Number Tons Compressor Rated Load Amps Locked Rotor Amps 3 8/13/13 14.1/23/23 98/158/158 ELECTRIC HEATER Electric Heater kw Electric Heater Full Load Amps N/A N/A INDOOR MOTOR SUPPLY FAN Horsepower 15.0 Motor speed (rpm) 1,760 Indoor motor full load amps 18.9 OUTDOOR MOTOR Number Horsepower Phase Outdoor motor full load amps 4 1.1 1 3.5 EXHAUST MOTOR Number Horsepower Phase Exhaust motor full load amps FILTERS (7) Type Furnished Number Recommended size Throwaway Yes 17 16"x20"x2" REFRIGERANT TYPE (6) Type R-410A Factory Charge (Circuit #1) 61.0 Ib Factory Charge (Circuit #2) Not Available Cooling MCA = (1.25 x Load 1) + Load 2 + Load 4 Cooling MOP = (2.25 x Load 1) + Load 2 + Load 4 Notes: 1, LOAD 1= Current of the largest motor (Compressor or Fan Motor); LOAD 2=Sum of the currents of all remaining motors LOAD 3= FLA(Full Load Amps) of the electric heater; LOAD 4= Any other load rated at 1 amp or more. 2. For Electric Heat MCA, MOP, RDE values, calculate for both cooling and heating modes. 3. If selected Max Over Cur is less than the Min Cir Amp, then select the lowest maximum fuse size which is equal to or larger than the Min Cir Amp, provided the selected fuse size does not exceed 800 amps. 4. The use of Liquid Propane (LP) requires unit modification. Contact a Trane salesman for information. 5. Compressor KW at AHRI rating conditions of 80/67 -95 6. Refrigerant charge is an approx. value. For a more precise value, see unit nameplate and service instructions. 7. Filter dimension are actual. Norminal filter size 15x20" FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 10 of 15 Inctmllmrl hu flthtarc Sabey IGW Bldg B - MM Fan Curve - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 0 5.0 = 4.5 1- 4.0 3,5 3.0 2.5 2.0 1.5 1.0 0.5 0,0 V 48 Uni(Madet484A t 5000DD On 3512» H2O AI' 70UP0 Rower:1432 bhp .00 213 F i6RP!! nn ui�i0 Oper04 Arcpow: Opere6ng Static Pressure Operafing R Operating Brake Horse — lf - n Temp:8 AltlWtl Design Design Temp:80.48 �_ _-- ll� / §pOPPk ksoaPnt AL.-,,� � ; AIL - 21IM - .gpRPtg ...wAilli.,..,_- NuRppw- ,,,.,..,011 _______ 1 1 1I-1 “, .._ I1 I III .! 11 1 1 I 1 1 1 1 1 1 1 0 Discharge duct: Return duct: Outdoor sound: 5000 63Hz 10000 125Hz 15000 20000 Airflow (cfm) 250Hz 500Hz 25000 1 kHz 2 kHz 30000 4 kHz 35000 8 kHz 99 91 83 83 77 75 71 66 91 90 85 82 77 75 74 75 104 97 96 97 95 93 88 79 i FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 11 of 15 Installed by Othecc Sabey IGW Bldg B - MM Weight, Clearance & Rigging Diagram - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 84" - 72" CLEARANCE NOTES: 1. HORIZONTAL AND DOWNFLOW UNITS, ALL SIZES. 2. CONDENSER COIL IS LOCATED AT THE END AND SIDE OF THE UNIT. 3. CLEARANCES ON MULTIPLE UNIT INSTALLATIONS ARE DISTANCES BETWEEN UNITS. 4. ECONO / EXHAUST END MULTIPLE UNITS 144'. 5. CONDENSER COIL END/SIDE 192" TO 96" 6. SERVICE SIDE ACCESS 96" 48" 48" 96" 96" ESTIMATED OPERATING WEIGHT OPERATION WEIGHT: 6086.0 Ib CENTER OF GRAVITY OPTIONAL COMPONENTS X 42 Y 111" POWER EXHAUST '165.0 Ib BARO. RELIEF N/A SERVICE VALVES lls1/A CORNER LOADING PERCENTS ECONOMIZER 290.0 lb THRU-BASE ELECTRICAL .N/A DISC. SWITCH N/A A B C D E F MANUAL DAMPERS N/A GFI WITH DISCON. SWITCH N/A VFD .115.0 lb 17% 18% 19% 15% 16% 16`Y. ULTRA LOW LEAK EXH. '74.0 lb ULTRA LOVV LEAK ECON '114.0 lb COIL HAIL GUARD N/A MOD. HOT GAS REHEAT N/A WEIGHT NOTES: 1. THE WEIGHT SHOWN REPRESENTS THE TYPICAL UNIT OPERATING WEIGHT FOR THE CONFIGURATION SELECTED. ESTIMATED AT +/- 10 % OF THE NAMEPLATE WEIGHT. 2. THE ACTUAL WEIGHT IS STAMPED ON THE UNIT NAMEPLATE. FLD = Furnished by Trane U.S. inc. dba Trane / Inctalfpri by nthorc Equipment Submittal Page 12 of 15 Sabey IGW Bldg B - MM • Accessory - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 FRESH AIR HOOD POWER EXHAUST HOOD END OF UNIT C) 2 13/16' 32 1/8" 7 3/4" FRESH AIR AND POWER EXHAUST HOODS FOR DOWNFLOW RETURN UNIT DETAIL FLD = Fumished by Trane U.S. Inc. dba Trane / Inctall.ri Fitt (Whom Equipment Submittal Page 13 of 15 Sabey IGW Bldg B MM • Accessory - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 EXHAUST HOOD EXHAUST HOOD 34 1/16" 40 1/2" 13 5/16" FRESH AIR HOOD --- TOP VIEW DIMENSIONAL DRAWING 61 /8" EXHAUST HOOD 41" FRESH AIR HOOD BACK VIEW DIMENSIONAL DRAWING ISOMETRIC VIEW PARTIAL DRAWING 32 1/8" 23 7/8" 20 3/4" SIDE VIEW DIMENSIONAL DRAWING 40-50 TON FRESH AIR AND POWER EXHAUST HOODS HORIZONTAL CONFIGURATION DIMENSIONAL DRAWING FLD = Furnished by Trane U,S. Inc. dba Trane / Equipment Submittal Page 14 of 15 Installed by Others Sabey IGW Bldg B - MM Field Wiring - Packaged Rooftop, Cooling / Heating Units Item: Al Qty: 1 Tag(s): RTU-1 December 12, 2019 L7B1 149 TEST I 137 TEST 2 36 20 132 19 133 18 17 93 16 119 15 113 14 118 13 49 12 46 11 79 10 78 77 8 76 7 75 6 74 73 4 72 71 70 - 2 - _ N:0[ HTB1 1 I • `-ki Iv - t ..„ ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMUM WIRE LENGTH in 22 GAUGE 1800" 20 GAUGE 3000" 18 GAUGE 4500" 16 GAUGE 7200" 14 GAUGE 11700" NOTE: 1. All wiring and devices shown dashed to be supplied and installed by the customer in accordance with national and local electrical codes. 2. Low voltage control wiring must not be run in conduit with power wiring. 3. Cut wire jumper adjacent to the terminal 1 on zone sensor. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 15 of 15 InctallAri hv nthprc Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAVV201 FILE COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: Mo1Hr 6118 Mo/Hr; 6 118 MoIHr: Heating Design Outside Air: OADBIWBIHR; 17164169 OADB:77 OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total, Sensible Of Total ; Space Sens Tot Sens Of Total Btufh Btufh Btufh (%) Btufh (%) , Btulh Btufh (%) Envelope Loads ' Envelope Loads Skylite Solar 0 0 0 01 0 0 1 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0' 0 0 Roof Cond 0 0 0.00 Glass Solar 21,600 0 21,600 661 21,600 80 ; Glass Solar 0 0 0.00 Glass/Door Cond 203 0 203 1, 203 1 Glass/DoorCond -6,106 -6,106 41.82 Wall Cond 1,246 658 1,904 6 1,246 5 Wall Cond -979 -1,498 10.26 Partition/Door 0 0 0' 0 0' Partition/Door 0 0 0.00 Floor 0 0 0, 0 0, Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 295 295 1' 125 0' Infiltration -3,401 .3,401 23.30 Sub Total==> 23,344 658 24,002 741 23,174 86 1 Sub Total==> -10,486 -11,005 75.38 lntemal Loads Internal Loads 0 Lights . 1,835 459 2,294 7' 1,835 7 Lights 0 0.00 People 3,150 0 3,150 10 1,750 7 People 0 0 0.00 Misc 0 0 0 0 0 0, Misc 0 0 0.00 Sub total==> 4,985 459 5,444 17 3,585 13 1 Sub Total:*0 0 0.00 Ceiling Load 120 -120 0 01 120 0 , Ceiling Load -54 0 0.00 Ventilation Load 0 0 331 1 0 0 Ventilation Load 0 •3,812 26.11 Adj Air Trans Heat 0 0 0 ' 0 0 ' Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0' ' OvlUndr Sizing 0 0 0.00 OvlUndr Sizing 0 0 0 , 0 0 ,Exhaust Heat 40 -0.27 Exhaust Heat 88 -88 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 2,855 9' RA Preheat Diff. 0 0,00 Ret, Fan Heat 0 0 01 Additional Reheat 0 0,00 Duct Heat Pkup 0 0 0 System Plenum Heat 179 -1.22 Underflr Sup Ht Pkup 0 0' ' Uncle* Sup Ht Pkup 0 0,00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0,00 Grand Total=> , 28,449 909 32,544 100.00' 26,879 100,001 Grand Total=_> -10,539 14,599 100.00 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infd MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups SADB Ra Plenum Return ReUOA Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling Heating 59.8 79,9 75,6 69.8 75.6 69,8 75.6 62,6 0.2 0,0 0.4 0.0 1.1 0.0 AIRFLOWS Cooling Heating 1,606 964 1,606 964 1,606 482 0 482 75 7 75 75 67 67 482 482 1,673 549 143 143 0 0 0 0 0 ENGINEERING CKS Cooling Heating % 4.7 5,2 cfmlft' 2.39 1,43 cfmiton 592.16 ft'lton 247,79 Btulhr-ft' 48.43 -29.43 No. People 7 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBPWBIHR ton 1 f MBh MBh cfm °F °F gr./lb °F °F grllb Main Clg flEG I Y ED5 30.8 1,606 75,6 62.7 65.8 58.2 56.0 64.2 AcITY OF U K1 ILA 0.0 0 0.0 0.0 0.0 0,0 0.0 0.0 Opt Vent ' 0.0 0,0 0.0 0 0.0 0.0 0.0 0,0 0,0 0.0 Total DEC 18 2 AREAS Gross Total Glass ft1 (%) Floor 672 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wall 768 259 34 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -16.9 964 64.0 79,9 Aux Htg 0.0 0 0.0 0.0 Preheat -2.8 75 24.0 58.2 Reheat -6.3 482 58.2 70.0 Humidif 0,0 0 0.0 0,0 Opt Vent 0.0 0 0.0 0.0 Total -19.8 02,07 Proje�f M�a � p ark TRACE® 700 v6.3.3 calculated at 02:54 PM on 12102/2019 Dataset Name: SABEY.TRC Isit9lb Alternative -1 System Checksums Report Page 1 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV 202 COOLING COIL PEAK Peaked at Time: Mo/Hr: 6I 15 Outside Air: OADBIWBIHR: 80 167 178 CLG SPACE PEAK Mo/Hr. 7115 OADB: 82 HEATING COIL PEAK Mo/Hr. Heating Design OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total, Sensible Of Total , Space Sens Tot Sens 0f Total Btulh Btulh Btulh (%j,r Btulh (%) Btum Btulh (°A) Envelope Loads ' Envelope Loads Skylite Solar 0 0 0 0, 0 0, Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 01 0 0 Roof Cond 0 0 0.00 Glass Solar 4,175 0 4,175 291 4,002 43 ' Glass Solar 0 0 0,00 Glass/Door Cond 381 0 381 3, 546 6, Glass/Door Cond -5,495 -5,495 41.52 Wall Cond 207 116 323 2 217 2 Wall Gond •724 .1,144 8.64 Partition/Door 0 0 0' 0 0' Partition/Door 0 0 0.00 Floor 0 0 0, 0 0, Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0,00 Infiltration 746 746 5' 392 4' Infiltration -2,576 -2,576 19.47 Sub Total =_> 5,509 116 5,625 39 5,157 55 r Sub Total => -8,795 -9,216 69.63 Internal Loads ' internal Loads Lights 1,390 347 1,737 12 ' 1,390 15 ' Lights 0 0 0.00 People 4,950 0 4,950 341 2,750 29 ' People 0 0 0,00 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Sub Total==> 6,340 347 6,687 46 4,140 44 Sub Total==> 0 0 0.00 Ceiling Load 91 •91 0 0 , 91 1, Ceiling Load -41 0 0.00 Ventilation Load 0 0 1,254 9 0 0 Ventilation Load 0 -4,330 32.71 Adj Air Trans Heat 0 0 0 ' 0 0 ' Adj Air Trans Heat 0 0 0 Dehumld. Ov Sizing 0 0' ' OvlUndr Sizing 0 0 0.00 Ov/UndrSizing 0 0 0, 0 0 Exhaust Heat 38 -0,29 Exhaust Heat -85 -85 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 987 7' ' RA Preheat Diff, 0 0.00 Ret. Fan Heat 0 0 0, , Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat 272 -2,05 Underflr Sup Ht Pkup 0 0' ' Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0, , Supply Air Leakage 0 0.00 Grand Total=> 11,940 287 14,468 100.00 9,388 100,00 Grand Total==> -8,836 -13,235 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBANBIHR ton MBh MBh cfm °F °F grllb °F °F grOb Main Clg 1,2 14,5 11.1 555 76.3 63.3 67,6 58.2 54.6 58.8 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0,0 0 0,0 0,0 0,0 0,0 0,0 0.0 Total 1.2 14.5 Project Name: Pacific View Office Park Dataset Name: SABEYTRC AREAS Gross Total Glass ft2 (% Floor 509 Part 0 Int Door 0 ExFlr 0 Roof 0 0 0 Wall 622 233 37 Ext Door 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent InfiI MinStoplRh Return Exhaust Rm Exh Auxiliary leakage Dwn Leakage Ups SADB Ra Plenum Retum RetIOA Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling Heating 59.8 93.9 75,6 69,8 75.6 69.8 76.3 46,5 0.2 0.0 0.4 0,0 1,1 0.0 AIRFLOWS Cooling Heating 561 337 561 337 561 168 0 168 86 86 86 86 51 51 168 168 612 219 136 136 0 0 0 0 0 0 0 0 ENGINEERING CKS Cooling Heating % 0A 15.3 16.9 cfmlft2 1.10 0,66 cfmlton 465,23 ft2Iton 422.17 Btulhr•fr 28,42 -28.07 No. People 11 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -11.1 337 64,0 93.9 Aux Htg 0.0 0 0.0 0.0 Preheat -3.2 86 24.0 58,2 Reheat -2.2 168 58.2 70,0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total •14.3 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12102/2019 Alternative • 1 System Checksums Report Page 2 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV.203 COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: Mo/Hr.6111 Mar: 6I10 , MolHr: Heating Design Outside Air: OADBPWBIHR: 74 / 64 177 OADB: 71 OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat. Sens, + Lat Total Of Total, Sensible Of Total , Space Sens Tot Sens Of Total Btulh Btulh Btulh (%) Btulh (%) Btulh Btulh (%) Envelope Loads ' ' Envelope Loads Skylite Solar 0 0 0 01 0 0 1 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0, 0 0 Skylite Cond 0 0 0.00 Roof Gond 0 0 0 01 0 0 Roof Cond 0 0 0.00 Glass Solar 12,052 0 12,052 43' 12,722 61 ' Glass Solar 0 0 0.00 Glass/Door Cond -335 0 -335 -1, -566 -3 , Glass/Door Cond -4,885 -4,885 29.26 Wall Cond 541 275 816 3 480 2 Wall Cond -833 -1,263 7.57 PartiiionlDoor 0 0 0' 0 0' PartitionlDoor 0 0 0.00 Floor 0 0 0, 0 0, Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 369 369 1' -270 -1' Infiltration -2,961 -2,961 17.74 Sub Total==> 12,627 275 12,902 461 12,365 59 ! Sub Total==> -8,679 -9,109 54.56 Internal Loads , Internal Loads Lights 1,597 399 1,997 7 ' 1,597 8 ' Lights 0 0 0.00 People 8,100 0 8,100 29' 4,500 21' People 0 0 0.00 Misc 2,400 0 2,400 8 i 2,400 11 1 Misc -1,463 -1,463 8.76 Sub Total ==> 12,097 399 12,497 44 8,497 41 Sub Total:* -1,463 -1,463 8.76 , Ceiling Load 107 •107 0 0 105 0 ,Ceiling Load -47 0 0.00 Ventilation Load 0 0 789 3 0 0 Ventilation Load 0 6,332 37.93 Adj Air Trans Heat 0 0 0 0 0 1 Adj Air Trans Heat 0 0 0 Dehumid.Ov Sizing 0 0' ' OvlUndr Sizing 0 0 0.00 OvlUndr Sizing 0 0 0, 0 0 ,Exhaust Heat 51 -0.31 Exhaust Heat -117 -117 0 OA Preheat Diff, 0 0.00 Sup. Fan Heat 2,206 8' ' RA Preheat Diff, 0 0,00 Ret, Fan Heat 0 0 0, 1 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat 158 -0.95 Underflr Sup Ht Pkup 0 0' ' Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 , , Supply Air Leakage 0 0.00 Grand Total => 24,831 450 28,277 100.00 20,967 100.00 ' Grand Total =_>-10,188 -16,694 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBIWBIHR ion MBh MBh cfm °F °F grpb °F °F grIlb Main Clg 2.4 28.3 23,2 1,241 75,4 62.8 66.8 58.2 55.2 61.2 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0,0 0.0 0.0 Opt Vent 0.0 0,0 0.0 0 0.0 0.0 0.0 0.0 0,0 0, Total 2.4 28.3 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass ft= (%) Floor 585 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wall 637 207 32 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 59.8 82.3 Ra Plenum 75.6 69.8 Return 75.6 69.8 RetiOA 75,4 54.5 Fn MtrTD 0.2 0.0 Fn BIdTD 0.4 0.0 Fn Frict 1,1 0.0 AIRFLOWS Cooling Heating Diffuser 1,253 752 Terminal 1,253 752 Main Fan 1,253 376 Sec Fan 0 376 Nom Vent 125 125 AHU Vent 125 125 Infil 59 59 MinStop/Rh 376 376 Return 1,311 434 Exhaust 184 184 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating °4 OA 10.0 11.1 cfmlft' 2.14 1.28 cfmlton 531,63 fflton 248.26 Btulhrft' 48.34 -33.99 No. People 18 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm 'F °F Main Htg -15.2 752 64.0 82,3 Aux Htg 0.0 0 0,0 0.0 Preheat -4.7 125 24,0 58.2 Reheat -4.9 376 58.2 70.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -19.9 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12/0212019 Alternative -1 System Checksums Report Page 3 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV•204 COOLING COIL PEAK Peaked at Time: MofHr: 6111 Outside Air: OADBIWBIHR: 74 164177 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total => tntemal Loads Lights People Misc Sub Total => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. 0v Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret, Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total => Space Plenum Sens. + Lat. Sens. + Lat Btu/h Btulh 0 0 0 0 0 0 10,076 0 -292 0 668 334 0 0 0 0 242 10,694 334 1,046 261 3,600 0 1,707 0 6,352 261 70 -70 0 0 0 0 397 0 0 0 -65 .65 1,616 8' 0 0 0, 0 0 0 0 0' 0 0 0, Net Total Btulh 0 0 0 10,076 -292 1,002 0 0 0 242 11,028 1,307 3,600 1,707 CLG SPACE PEAK MolHr, 6 / 10 OADB: 71 Percent' Space 0f Total, Sensible Btu/h 0r 0 0 0 0 0 51' 10,582 -1, -493 5 599 00 0, 0 0 0 1' -177 56 10,511 7' 18' 9 1,046 2,000 1,707 6,614 34 4,752 Percent' 0f Total (%) Envelope Loads 0 i Skylite Solar 0 Skylite Cond 0 Roof Cond 69 ' Glass Solar •3 , Glass/Door Cond 4 Wall Cond 0' Partition/Door 0 , Floor 0 Adjacent Floor •1' Infiltration 69' Sub Total==> Internal Loads 7 ' Lights 13 r People 11 , Misc 31 Sub Total==> 0 0 r 68 0 Ceiling Load 2 0 0 Ventilation Load 0 ' 0 0 ' Adj Air Trans Heat 0' ' Ov/Undr Sizing 0, 0 0 Exhaust Heat 0 0A Preheat Diff, ' RA Preheat Diff. Additional Reheat System Plenum Heat ' Underflr Sup Ht Pkup Supply Air Leakage 17,116 461 19,590 100.00 15,332 100.00 Grand Total => HEATING COIL PEAK MolHr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btulh Btulh (%) 0 0 0.00 0 0 0,00 0 0 0.00 0 0 0.00 -4,274 4,274 37.84 -770 -1,158 10.26 0 0 0,00 0 0 0.00 0 0 0.00 -1,939 .1,939 17,16 -6,982 -7,371 65.26 0 0 0.00 0 0 0.00 -958 -958 8.48 -958 •958 8.48 -31 0 0.00 0 -3,188 28.22 0 0 0 0 0 0.0 28 -0.25 0 0.00 0 0.00 0 0.00 194 -1.72 0 0,00 0 0.00 -7,970 -11,294 100.00 Total Capacity ton MBh Main Clg 1.6 19.6 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 1.6 19.6 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWBIHR MBh cfm °F °F grub 17.2 909 75,4 62.8 66.4 0.0 0 0,0 0.0 0.0 0.0 0 0,0 0.0 0.0 Leave DBIWBIHR °F °F grIlb 58.2 55,6 62.8 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass (%) Floor 383 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wall 575 181 31 Ext Door 0 0 0 SADB Ra Plenum Return ReU0A Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling Heating 59.8 83.1 75.6 69,8 75.6 69,8 75.4 59.3 0.2 0.0 0.4 0.0 1,1 0.0 AIRFLOWS Cooling Heating Diffuser 916 552 Terminal 916 552 Main Fan 916 276 Sec Fan 0 276 Nom Vent 63 63 AHU Vent 63 63 In61 38 38 MinStoplRh 276 276 Return 954 314 Exhaust 101 101 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating OA 6.9 7.6 cfm/WN 2.39 1.44 cfmlton 561.11 ft'lton 234.61 BtulhrfN 51.15 -36.57 No. People 8 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -11.6 552 64,0 83.1 Aux Htg 0.0 0 0.0 0.0 Preheat •2.4 63 24.0 58.2 Reheat -3.6 276 58.2 70.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0,0 0.0 Total -14.0 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12/02/2019 Alternative • 1 System Checksums Report Page 4 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV•105 COOLING COIL PEAK Peaked at Time: MoIHr 6111 Outside Air: OADBANBIHR: 74 164177 CLG SPACE PEAK MoIHr 6110 OADB: 71 HEATING COIL PEAK Mo/Hr: Heating Design OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total , Sensible 0f Total , Space Sens Tot Sens 0f Total Btu/h Bluth Btulh (%) Bluth (1/4)Btulh Bluth (%) Envelope Loads 1 ' Envelope Loads Skylite Solar 0 0 0 0' 0 0 1 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 01 0 0 1 Roof Cond 0 0 0.00 Glass Solar 13,155 0 13,155 551 14,033 73' Gass Solar 0 0 0.00 Glass/Door Cond -293 0 -293 -1 -495 -3 Glass/Door Cond -4,274 -4,274 37.00 Wall Cond 653 366 1,018 4 587 3 Wall Cond -600 -938 8.12 Partition/Door 0 0 0' 0 0' Partition/Door 0 0 0.00 Floor 0 0 0, 0 0, Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0,00 Infiltration 298 298 1' -219 -1' Infiltration -2,394 -2,394 20.72 Sub Total==> 13,613 366 14,179 60 13,907 72 i Sub Total==> -7,268 -7,606 65,84 Internal Loads 'Internal Loads Lights 1,291 323 1,614 7' 1,291 7' Lights 0 0 0.00 People 3,600 0 3,600 15! 2,000 10' People 0 0 0.00 Misc 2,048 0 2,048 9 2,048 11 Misc -612 -612 5.30 Sub Total =_> 6,939 323 7,262 31 5,339 28 Sub Total =_> -612 -612 5,30 Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing 0 0' OvlUndr Sizing 0 Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Unclear Sup Ht Pkup Supply Air Leakage 87 -87 0 0 85 0 , Ceiling Load -38 0 0.00 0 0 431 2 0 0 Ventilation Load 0 -3,481 29.96 0 0 0' 0 0' Adj Ar Trans Heat 0 0 0 ' OvlUndr Sizing 0 0 0.00 0 0, 0 0 1 Exhaust Heat 32 -0.28 -74 -74 0 OA Preheat Diff. 0 0.00 2,004 8' RA Preheat Diff. 0 0.00 0 0 0, , Additional Reheat 0 0.00 0 0 0 System Plenum Heat 94 -0.82 0 0' 0 0 0, Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0.00 Grand Total=> 20,840 528 23,803 100.00' 19,330 100.00 Grand Total.* -7,918 -11,553 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBIWBIHR ton MBh MBh cfm °F °F grib °F °F grllb Main Clg 2.0 23.8 21.3 1,127 75.5 62.8 66.3 58.2 55.7 63.3 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0,0 0.0 0 0.0 0,0 0,0 0.0 0.0 0.0 Total 2.0 23.8 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass ft' (%) Floor 473 Part 0 Int Door 0 ExFlr 0 Roof 0 0 0 Wall 500 181 36 Ext Door 0 0 0 SADB Ra Plenum Return RetIOA Fn MtrTD Fn BldTD Fn Frict TEMPERATURES Cooling Heating 59.8 80.4 75.6 69.8 75.6 69.8 75.5 60.7 0.2 0.0 0.4 0.0 1.1 0.0 AIRFLOWS Cooling Heating Diffuser 1,155 6 Terminal 1,155 693 Main Fan 1,155 346 Sec Fan 0 346 Nom Vent 68 68 AHU Vent 68 68 Infil 47 47 MinStopfRh 346 34 Return 1,202 394 Exhaust 116 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 ENGINEERING CKS Cooling Heating % OA 5.9 6,6 cfmlft2 2.44 1.47 cfm/ton 582,26 ft'Iton 238.46 Btulhrft' 50.32 -31,91 No. People 8 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg •12,5 693 64.0 80.4 Aux Htg 0.0 0 0.0 0.0 Preheat -2,6 68 24.0 58.2 Reheat -4.5 346 58.2 70.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -15,1 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12/02/2019 Alternative -1 System Checksums Report Page 5 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV 206 COOLING COIL PEAK Peaked at lime: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total => Mo/Hr. 6I11 OADBIWBIHR: 74 164I 77 Space Plenum Sens. + Lat. Sens. + Lat Btulh Btulh 0 0 0 7,532 -168 368 0 0 0 204 7,936 Internal Loads Lights 2,255 People 10,080 Misc 3,507 Sub Total =_> 15,842 Ceiling Load Ventilation Load Adj Air Trans Heat Dehumld. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret, Fan Heat Duct Heat Pkup Unclerflr Sup Ht Pkup Supply Air Leakage Net Total Btulh 0 0 0 0 0 0 0 7,532 0 .168 207 575 0 0 0 0 204 207 8,144 Percent Of Total , (%) CLG SPACE PEAK Mo1Hn 6110 OADB: 71 Space Sensible Bluth 0' 0 0 0 0' 0 28' 8,047 1 -283 2 331 0' 0 0, 0 0 0 1' -149 30 7,945 Percent 0f Total (%) Envelope Loads 0 i Skylite Solar 0 Skylite Cond 0 Roof Cond 45 ' Glass Solar -2 , Glass/Door Cond 2 Wall Cond 0' Partition/Door 0 ; Floor 0 Adjacent Floor -1 ' Infiltration 44 Sub Total =_> Internal Loads 564 2,819 10 ' 2,255 13 ' Lights 0 10,080 37' 4,121 23People 0 3,507 13 3,507 20 Misc 564 16,406 60 9,883 55 Sub Total ==> 152 -152 0 0, 148 1; Ceiling Load 0 0 1,019 4 0 0 Ventilation Load 0 0 0 0 0 Adj Air Trans Heat 0 0' ' OvlUndr Sizing 0 0 0; 0 0, Exhaust Heat -124 -124 0 OA Preheat Dif. 1,882 7 ' RA Preheat Diff, 0 0 0, , Additional Reheat 0 0 0 System Plenum Heat 0 0' ' Underflr Sup Ht Pkup 0 0 0 i Supply Air Leakage Grand Total => 23,930 496 27,327 100.00 17,976 100.00 ' Grand Total:* HEATING COIL PEAK Mo/Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Blum Btulh (%) 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 -2,442 -2,442 17.96 -337 -529 3.89 0 0 0.00 0 0 0.00 0 0 0.00 -1,635 -1,635 12.02 .4,415 -4,606 33,87 0 0 0.00 0 0 0.00 -808 -808 5.94 •808 -808 5.94 -66 0 0.00 0 -8,177 60.13 0 0 0 0 0 0.00 54 -0.40 0 0.00 0 0.00 0 0.00 -63 0.46 0 0.00 0 0.00 -5,288 -13,600 100.00 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups SADB Ra Plenum Return Ret10A Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling 59.8 75.6 75.6 75.3 0.2 0.4 1.1 Heating 77.5 69.8 69,8 46.8 0.0 0.0 0.0 AIRFLOWS Cooling Heating 1,074 645 1,074 645 1,074 322 0 322 162 162 162 162 32 32 322 322 1,106 355 194 194 0 0 0 0 0 0 0 0 ENGINEERING CKS Cooling Heating % 15.0 16,7 cfmlfV 1.30 0,78 cfmlton 471.62 fPlton 362.72 Blulhr•ff 33.08 -18.95 No. People 7 Total Capacity ton MBh Main Clg 2.3 27.3 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 2.3 27.3 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWBIHR MBh cfm °F °F grub 19.8 1,059 75,3 62.9 67.4 0.0 0 0.0 0,0 0.0 0,0 0 0.0 0.0 0.0 Leave DBIWBIHR °F °F grIlb 58.2 54.2 57.3 0,0 0.0 0.0 0,0 0.0 0,0 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass ft' (%) Floor 826 Part 0 Int Door 0 EzFtr 0 Roof 0 0 0 Wall 283 103 36 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg -9.6 645 64.0 Aux Htg 0.0 0 0.0 Preheat -6,1 162 24.0 Reheat -4.2 322 58.2 Humidif 0.0 0 0.0 Opt Vent 0.0 0 0.0 Total •15,7 Lvg °F 77.5 0.0 58.2 70.0 0.0 0,0 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12102/2019 Alternative -1 System Checksums Report Page 6 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV 207 COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat Dehumld. Ov Sizing Ov/Undr Sizing Exhaust Heat Sup. Fan Heat Ret, Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total => CLG SPACE PEAK Mo/Hr: 6I14 , MoIHr:10I 18 OADBIWBIHR: 80 167 181 OADB: 64 Space Plenum Net Percent' Space Sens, + Lat. Sens. + Lat Total Of Total Sensible Btulh Btulh BtuTh (%) Bluth 0 0 0 01 0 0, o 0 0 0 0 0 0 0 0 0' 0 0' 0 0 0 0' 0 0' 0 0 0 0, 0 0, 0 0 0 0 0 0 0 0 0' 0 0' 0 0 0, 0 0, 0 0 0 0 0 0 0 0 0' 0 0' 0 0 0 0' 0 0' 707 177 884 13' 707 18' 3,600 0 3,600 52 i 2,000 50 1 1,200 0 1,200 17 1,200 30 5,507 177 5,684 82 3,907 99 , 48 -48 0 0, 54 0 0 854 12 , 0 0 0 0 0 0 0' 0 0 0, 0 -35 -35 -1 426 6' 0 0 0, 0 0 0 0 0' 0 0 0, Percent' 0f Total (°6) , Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond ParlitionlDoor Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total==> 1 ; Ceiling Load 0 Ventilation Load 0 ' Adj Air Trans Heat OvlUndr Sizing 0 Exhaust Heat OA Preheat Diff, RA Preheat Diff, Additional Reheat System Plenum Heat ' Undertlr Sup Ht Pkup Supply Air Leakage 5,555 94 6,928 100.00 3,961 100,00 Grand Total => HEATING COIL PEAK MolHr: Healing Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens 0f Total Btulh Btulh (%) 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0,00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 -21 0 0.00 0 -2,811 98.43 0 0 0 0 0 0.00 15 -0.54 0 0.00 0 0.00 0 0.00 -60 2.11 0 0.00 0 0.00 -21 -2,856 100.00 Total Capacity ton MBh Main Clg 0.6 6.9 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 0.6 6.9 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWBIHR MBh cfm °F °F grllb 4.8 240 76.6 63.8 69.3 0.0 0 0.0 0.0 0.0 0.0 0 0,0 0.0 0,0 leave DBIWBIHR °F °F grit 58.4 54.1 56.5 0,0 0.0 0.0 0.0 0.0 0.0 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS. Gross Total Glass ft2 (%) Floor 259 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 SADB Ra Plenum Retum RetNOA Fn MtrTD Fn BldTD Fn Frict TEMPERATURES Cooling Heating 60.0 70,1 75.6 69.8 75.6 69,8 76.6 34.5 0.2 0,0 0.4 0.0 1.1 0,0 AIRFLOWS Cooling Heating Diffuser 240 144 Terminal 240 144 Main Fan 240 72 Sec Fan 0 72 Nom Vent 56 56 AHU Vent 56 56 Infil 0 0 MinStoplRh 72 72 Return 240 72 Exhaust 56 56 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating VD OA 23.1 25,7 cfm/ft' 0.93 0.56 cfmlton 415.68 ftfton 448.58 Blulhrff 26.75 -11.82 No. People 8 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -1,0 Aux Htg 0.0 Preheat -2.1 Reheat -0.9 Humidif 0.0 Opt Vent 0.0 Total •3,1 144 64.1 70,1 0 0.0 0.0 56 24.0 58.4 72 58.4 70,0 0 0.0 0.0 0 0.0 0.0 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12102/2019 Alternative • 3 System Checksums Report Page 26 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV•208 COOLING COIL PEAK Peaked at Time: MoIHr: 6114 Outside Air: OADBAWBIH R: 80 167181 CLG SPACE PEAK HEATING COIL PEAK Mo1Hr:10118 MoIHr: Heating Design OADB: 64 OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total ; Sensible Of Total , Space Sens Tot Sens Of Total Bluth Blum Btulh (%) Btulh (%) Btulh Btulh (°/°) Envelope Loads ' Envelope Loads Skylite Solar 0 0 0 0, 0 0[ Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 I Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 f 0 0' Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0, 0 0 1 Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 01 0 0' Partition/Door 0 0 0.00 Floor 0 0 0, 0 0, Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 0 0 0 0 0' Infiltration 0 0 0.00 Sub Total =_> 0 0 0 01 0 01 Sub Total =_> 0 0 0.00 Internal Loads ' Internal Loads Lights 2,228 557 2,785 22 ' 2,228 24 1 Lights 0 0 0.00 People 2,250 0 2,250 17 i 1,250 13' People 0 0 0,00 Misc 5,800 0 5,800 45 5,800 61 Misc 0 0 0.00 Sub Total =_> 10,278 557 10,835 84 9,278 98 Sub Total =_> 0 0 0,00 Ceiling Load 150 -150 0 0, 170 2 1 Ceiling Load -65 0 0.00 Ventilation Load 0 0 1,137 9 0 0 Ventilation Load 0 -3,744 96.42 Adj Air Trans Heat 0 0 0 ' 0 0 ' Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0' ' Ovlundr Sizing 0 0 0.00 OvlUndr Sizing 0 0 0, 0 0, Exhaust Heat 20 •0.52 Exhaust Heat -47 -47 0 OA Preheat Diff, 0 0.00 Sup. Fan Heat 1,015 8' ' RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0, , Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -159 4,11 Underflr Sup Ht Pkup 0 0' ' Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 01 I Supply Air Leakage 0 0.00 Grand Total =_> 10,428 360 12,940 100.00 9,448 100.00 Grand Total => -65 -3,883 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBANBIHR Leave DBIWBIHR ton MBh MBh cfm °F °F grub °F °F gr/lb Main Clg 1.1 12.9 11.2 571 76.1 63.3 67.8 58.4 55.8 63.3 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0,0 0.0 0,0 0.0 0.0 0,0 Total 1.1 12,9 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass ft2 (%) Floor 816 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wail 0 0 0 Ext Door 0 0 0 % OA cfmlft2 cirri/ton non Btulhr•ft' No. People Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent lnfil MinStoplRh Retum Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups TEMPERATURES Cooling Heating SADB 60.0 70.2 Ra Plenum 75,6 69,8 Retum 75.6 69.8 ReUOA 76.1 50.1 Fn MtrTD 0.2 0.0 Fn BIdTD 0.4 0,0 Fn Frict 1.1 0,0 AIRFLOWS Cooling Heating 572 343 572 343 572 172 0 172 74 74 74 74 0 0 172 172 572 172 74 74 0 0 0 0 0 0 0 0 ENGINEERING CKS Cooling Heating 12.9 14.4 0.70 0.42 530.86 756.74 15.86 -6.26 5 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -2,3 343 64.1 70,2 Aux Htg 0,0 0 0,0 0.0 Preheat -2.8 74 24,0 58.4 Reheat -2.2 172 58.4 70,0 Humidif 0.0 0 0.0 0.0 Opt Vent 0,0 0 0.0 0.0 Total -5.1 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12102/2019 Alternative - 3 System Checksums Report Page 27 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV•209 COOLING COIL PEAK Peaked at Tme: MoIHr: 6114 Outside Air: OADBI BIHR: 80 167 181 CLG SPACE PEAK HEATING COIL PEAK Mo/Hr. 7115 Mo/Hr: Heating Design OADB: 82 OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat. Sens. + Lat Total Of Total , Sensible Of Total , Space Sens Tot Sens Of Total Multi Btuh Btulh (%) Blwh (%) Btut Btulh (%) Envelope Loads 1 Envelope Loads Skylite Solar 0 0 0 01 0 0 i Skylite Solar 0 0 0,00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 I 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 01 0 0' Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0 0 0, Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0' 0 0' Parlition/Door 0 0 0.00 Floor 0 0 0, 0 0, Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 816 816 9' 409 6' Infiltration -2,688 -2,688 48.92 Sub Total =_> 816 0 816 9 ' 409 6 , Sub Total =_> -2,688 -2,688 48.92 Internal Loads ' Internal Loads Lights 1,862 466 2,328 26' 1,862 29' Lights 0 0 0.00 People 900 0 900 101 500 8 ' People 0 0 0.00 Misc 3,606 0 3,606 40 3,606 55 Misc 0 0 0.00 1 Sub Total==> 6,368 466 6,833 75 5,968 92 Sub Total==> 0 0 0.00 Ceiling Load 125 -125 0 0, 121 2 , Ceiling Load -54 0 0,00 Ventilation Load 0 0 821 9 0 0 Ventilation Load 0 -2,702 49.18 Adj Air Trans Heat 0 0 0 0 0' Adj Air Trans Heat 0 0 0 Dehumid.OvSizing 0 0' ' OvlUndr Sizing 0 0 0.00 OvlUndr Sizing 0 0 0 0 0 1 Exhaust Heat 29 -0.53 Exhaust Heat -68 -68 -1 OA Preheat Diff. 0 0.00 Sup, Fan Heat 687 8' ' RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0, 1 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -134 2.44 Underflr Sup Ht Pkup 0 0' ' Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0, I Supply Air Leakage 0 0.00 Grand Total => 7,310 272 9,089 100.00 ' 6,498 100.00 Grand Total =_> -2,742 -5,494 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBIWBIHR ton MBh MBh cfm °F °F grub °F °F grub Main Clg 0.8 9.1 7.6 386 76.2 63.4 67.9 58.4 55.5 62.2 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0,0 Total 0.8 9.1 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass it: (%) Floor 682 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent lnfil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups SADB Ra Plenum Return RetIOA Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling Heating 60.0 80.5 75.6 69.8 75,6 69,8 76.2 49.1 0.2 0.0 0.4 0.0 1.1 0.0 AIRFLOWS Cooling Heating 394 236 394 236 394 118 0 118 53 53 53 53 53 53 118 118 447 171 106 106 0 0 0 0 0 0 0 0 ENGINEERING CKS Cooling Heating % 13.6 15.1 cfmlft2 0.58 0.35 cfmlton 519.77 ft'Iton 900.40 Btulhrft2 13.33 -9.24 No. People 2 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -4,3 236 64.1 80,5 Aux Htg 0.0 0 0.0 0.0 Preheat -2.0 53 24,0 58.4 Reheat -1.5 118 58.4 70,0 Humidif 0.0 0 0.0 0.0 Opt Vent 0,0 0 0.0 0.0 Total -6.3 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12/02/2019 Alternative • 3 System Checksums Report Page 28 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV 210 COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: MoIHr: 6114 I MoWhir:10118 , MoIHr. Heating Design Outside Air; OADBIWBIHR:80167181 OADB: 64 OADB: 24 Space Plenum Net Percent ; Space Percent : Space Peak Colt Peak Percent Sens. + Lat. Sens. + Lat Total Of Total , Sensible Of Total , Space Sens Tot Sens Of Total Bluth Btulh Btulh (%)1 Bluth (%) Btulh Btulh (%) Envelope Loads ' Envelope Loads Skylite Solar 0 0 0 0 i 0 0 i Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 01 0 0' Roof Cond 0 0 0.00 Glass Solar 0 0 0 0' 0 0' Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0, 0 0, Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Parlilion/Door 0 0 0' 0 0' Partition/Door 0 0 0.00 Floor 0 0 0, 0 0; Floor 0 0 0,00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 0 0 0' 0 0' Infiltration 0 0 0.00 Sub Total =_> 0 0 0 01 0 01 Sub Total =_> 0 0 0.00 Internal Loads ' Internal Loads Lights 4,161 1,040 5,201 291 4,161 441 Lights 0 0 0.00 People 9,000 0 9,000 50' 5,000 53' People 0 0 0.00 Misc 0 0 0 0 0 0, Misc 0 0 0,00 Sub Total ==> 13,161 1,040 14,201 79 9,161 97 Sub Total.* 0 0 0.00 i Ceiling Load 280 -280 0 0 318 3 , Ceiling Load •121 0 0.00 Ventilation Load 0 0 2,944 16 0 0 Ventilation Load 0 -9,690 98.24 Adj Air Trans Heat 0 0 01 0 0' Adj Air Trans Heat 0 0 0 Dehumid, Ov Sizing 0 0' ' OvNndr Sizing 0 0 0.00 OvlUndr Sizing 0 0 0, 0 0, Exhaust Heat 53 -0.53 Exhaust Heat -122 -122 -1 OA Preheat Diff, 0 0.00 Sup. Fan Heat 1,017 6' ' RA Preheat Diff. 0 0.00 Ret, Fan Heat 0 0 0, 1 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -226 2.30 Underflr Sup Ht Pkup 0 0' ' Unclerflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0, ' Supply Air Leakage 0 0.00 Grand Total => 13,441 638 18,040 100.001 9,479 100.00 Grand Total =_> -121 -9,864 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DB9NBIHR ton MBh MBh cfm °F °F gr/lb °F °F gr/lb Main Clg 1.5 18,0 12.1 572 77.0 64.2 70.8 58.4 53.7 55.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0,0 0.0 0.0 0.0 0.0 0.0 Total 1.5 18.0 Project Narne: Pacific View Office Park AREAS Gross Total Glass ft' (%) Floor 1,524 Part 0 Int Door 0 ExFlr 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 SADB Ra Plenum Return ReVOA Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling Heating 60.0 70.3 75.6 69.8 15.6 69.8 77.0 24,0 0.2 0.0 0.4 0.0 1.1 0.0 AIRFLOWS Cooling Heating Diffuser 574 383 Terminal 574 383 Main Fan 574 191 Sec Fan 0 191 Nom Vent 191 191 AHU Vent 191 191 Infil 0 0 MinStoplRh 191 191 Return 574 191 Exhaust 191 191 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 33.3 33.3 cfmlf12 0.38 0.25 cfmlton 382.04 non 1,013.76 Btulhrft' 11.84 -6.47 No. People 20 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -2.6 383 64,1 70,3 Aux Htg 0.0 0 0.0 0.0 Preheat -7,2 191 24.0 58.4 Reheat •2,5 191 58.4 70.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -9.9 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12/02/2019 Dataset Name: SABEY.TRC Alternative - 3 System Checksums Report Page 29 of 34 Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV•212 COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK Peaked at Time: MoIHr: 6118 MoWHr: 6118 Mo/Hr: Heating Design Outside Air: OADBANBIHR:77164169 OADB: 77 OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens. + Lat Sens. + Lat Total 0f Total , Sensible Of Total , Space Sens Tot Sens Of Total Blum Btufh Btulh (%) Btulh (%) Btulh Btulh (%) Envelope Loads ' Envelope Loads Skylite Solar 0 0 0 01 0 0 1 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0' 0 0' Roof Cond 0 0 0.00 Glass Solar 26,209 0 26,209 821 26,209 93' Glass Solar 0 0 0.00 GlasslDoorCond 245 0 245 1, 245 1, Glass/DoorCond -7,482 -7,482 49.41 Wall Cond 1,247 314 1,561 5 1,247 4 Wall Cond -981 -1,229 8.12 Partition/Door 0 0 0' 0 0' Partition/Door 0 0 0.00 Floor 0 0 0 0 0, Floor 0 0 0,00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 infiltration 438 438 1' 186 1' Infiltration5,052 -5,052 33.37 Sub Total =_> 28,139 314 28,453 89' 27,887 99 , Sub Total ->-13,515 •13,763 90.90 Internal Loads ' Internal Loads Lights 1,185 296 1,481 5 ` 1,185 4 ' Lights 0 0 0.00 People 0 0 0 0' 0 0' People 0 0 0.00 Mis o -1,085 0 -1,085 •3 r -1,085 -4, Misc 0 0 0.00 Sub Total =_> 100 296 396 1 100 0 Sub Total =_> 0 0 0.00 Ceiling Load 78 -78 0 0, 78 0 , Ceiling Load -35 0 0.00 Ventilation Load 0 0 114 0 0 0 Ventilation Load 0 -1,318 8.70 Adj Air Trans Heat 0 0 0' 0 0' Adj Air Trans Heat 0 0 0 Dehumid. 0v Sizing 0 0' ' Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0, 0 0 1 Exhaust Heat 35 -0.23 Exhaust Heat -78 -78 0 0A Preheat Diff, 0 0.00 Sup. Fan Heat 2,975 9' ' RA Preheat Diff. 0 0.00 Ret, Fan Heat 0 0 0, Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -95 0.63 Underflr Sup Ht Pkup 0 0' ' Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0, Supply Air Leakage 0 0.00 Grand Total==> 28,317 454 31,861 100,00 ' 28,064 100.00 Grand Total->-13,550 -15,141 100.00 COOLING COIL SELECTION AREAS Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBIWBIHR Gross Total Glass ton MBh MBh cfm °F °F grllb °F °F grOb ft' (%) Main Clg 2.7 31.9 31.5 1,674 75,6 62.7 65,7 58,1 56.3 65.7 Floor 434 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0,0 0.0 0.0 0.0 Part 0 Opt Vent 0.0 0,0 0.0 0 0,0 0.0 0.0 0.0 0.0 0A Int Door 0 ExFlr 0 Total 2.7 31.9 Roof 0 0 0 Wail 735 317 43 Ext Door 0 0 0 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC TEMPERATURES Cooling Heating SADB 59.8 82,3 Ra Plenum 75.6 69,8 Return 75.6 69.8 RetIOA 75,6 67,4 Fn MtrTD 0,2 0,0 Fn BIdTD 0,4 0.0 Fn Frict 1.1 0.0 AIRFLOWS Cooling Heating Diffuser 1,674 1,004 Terminal 1,674 1,004 Main Fan 1,674 502 Sec Fan 0 502 Nom Vent 26 26 AHU Vent 26 26 Infil 100 100 MinStoplRh 502 502 Retum 1,773 602 Exhaust 126 126 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % 1.6 1,7 cfmlft' 3.86 2,31 cfmlton 630.31 ff'Iton 163,46 Btulhr•ft' 73.41 -48.89 No. People 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -20,2 1,004 63.9 82.3 Aux Htg 0,0 0 0.0 0.0 Preheat -1,0 26 24.0 58,1 Reheat -6,6 502 58.1 70.0 Humidif 0,0 0 0.0 0.0 Opt Vent 0.0 0 0,0 0,0 Total -21.2 TRACE® 700 v6.3.3 calculated at 08:53 AM on 12/0312019 Alternative -1 System Checksums Report Page 12 of 34 r Zone Checksums By MACDONALD MILLER FACILITY SOLUTIONS VAV•113 COOLING COIL PEAK Peaked at Time: MolHr. 6 114 Outside Air: OAD BIWBI H R: 80 167 181 CLG SPACE PEAK HEATING COIL PEAK MoIHr: 7115 MoIHr: Heating Design OADB: 82 OADB: 24 Space Plenum Net Percent' Space Percent' Space Peak Coil Peak Percent Sens, + Lai Sens. + Lat Total Of Total , Sensible Of Total , Space Sens Tot Sens Of Total Btulh Btulh Btulh (%) Btulh (%) , Btulh Btulh {%) Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 I 0 0 1 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0' 0 0' Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0' 0 0' Partition/Door 0 0 0.00 Diffuser 252 151 Floor 0 0 0 0 0, Floor 0 0 0.00 Terminal 252 151 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 252 76 Infiltration 1,368 1,368 19' 686 16' Infiltration -4,505 4,505 61.66 Sec Fan 0 76 Sub Total ==> 1,368 0 1,368 191686 16; Sub Total.* 4,505 -4,505 61.66 NomVent 53 53 AHU Vent 53 53 Internal Loads I Internal Loads Infil 89 89 Lights 2,430 608 3,038 42I 2,430 58' Lights 0 0 0.00 MinStoplRh 76 76 People 1,602 0 1,602 22 890 21 People 0 0 0.00 Return 341 165 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 142 142 Sub Total =_> 4,032 608 4,640 65 3,320 80 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 163 -163 0 0 158 4 , Ceiling Load -71 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 821 11 0 0 Ventilation Load 0 •2,703 37.00 Leakage Ups 0 0 AdJ Air Trans Heat 0 0 0 1 0 01 Adj Air Trans Heat 0 0 0 Dehumld. Ov Sizing 0 0' 1 OvlUndr Sizing 0 0 0.00 Ov(Undr Sizing 0 0 0 0 0 1 Exhaust Heat 39 0.54 Exhaust Heat -91 -91 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 426 6' ' RA Preheat Diff. 0 0.00 Ret, Fan Heat 0 0 0, 1 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -137 1.87 Underflr Sup Ht Pkup 0 0' Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0, I Supply Air Leakage 0 0.00 TEMPERATURES Cooling Heating SADB 60,0 97.5 Ra Plenum 75.6 69,8 Return 75.6 69,8 Ret/OA 76.5 37.5 Fn MtrTD 0.2 0.0 Fn BldTD 0.4 0,0 Fn Frict 1.1 0.0 Grand Total => 353 7,164 100,00 4,163 100.00 Grand Total => -4,575 -7,305 100.00 AIRFLOWS ENGINEERING CKS Cooling Heating % 21.2 23.5 cfmlft' 0.28 0.17 cfmlton 422.53 ft'Iton 1,490.77 Btulhrft' 8.05 -8.52 No. People 4 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR Leave DBIWBIHR ton MBh MBh cfm °F °F grllb °F °F grIlb Main Cig 0,6 7.2 5.0 240 76.5 63,7 69.2 58,4 53.7 54.9 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0,0 0.0 0.0 0,0 0.0 Total 0.6 7.2 Project Name: Pacific View Office Park Dataset Name: SABEY.TRC AREAS Gross Total Glass 1t1 (%) Floor 890 Part 0 Int Door 0 ExFIr 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -5.6 151 64.1 97,5 Aux Htg 0,0 0 0.0 0.0 Preheat -2.0 53 24.0 58,4 Reheat -1.0 76 58.4 70.0 Humidif 0,0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -7.6 TRACE® 700 v6.3.3 calculated at 02:54 PM on 12/02/2019 Alternative - 3 System Checksums Report Page 32 of 34 City of Tukwila Department of Community Development December 03, 2021 AMMONE BEMBRY 7717 DETROIT AVE SW SEATTLE, WA 98106 RE: Extension Letter # 2 MECHANICAL Permit Number M19-0207 SABEY IGW B HQ RENOVATIONS - 12201 TUKWILA INTL BLVD 200 Dear Ammone, Allan Ekberg, Mayor Nora Gierloff, Director This letter is in response to your written request for an extension to your Permit M19-0207. The Department Director, or the Building Official has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila will be granting an extension to the permit through 7/8/2022. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Elizabeth Williams Permit Technician File No. M19-0207 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 City of Tukwila Department of Community Development 11 /30/202 1 AMMONE BEMBRY 7717 DETROIT AVE SW SEATTLE, WA 98106 RE: Permit No, M 19-0207 SABEY IGW - B HQ RENOVATIONS 12201 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Nora Gierloff, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/8/2022. Based on the above, you are hereby advised to: 1) If your project is ready for an inspection login to the City of Tukwila's Online Portal https://tukw- egov.aspgov.com/BP/index.html to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/8/2022, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Shana Markstrom Permit Technician File No: M19-0207 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Department of Community Development July 09, 2021 AMMONE BEMBRY 7717 DETROIT AVE SW SEATTLE, WA 98106 Allan Ekberg, Mayor Nora Gierloff, Director RE: Extension Letter # 1 MECHANICAL Application or Permit Number M19-0207 SABEY IGW - B HQ RENOVATIONS - 12201 TUKWILA INTERNATIONAL BLVD Dear AMMONE BEMBRY, This letter is in response to your written request for an extension to your Application or Permit M19-0207, The Building Official, Jerry Hight has reviewed your letter and considered your request to extend the above referenced application or permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through 1/8/2022. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Laurie Werle Permit Technician File No. M19-0207 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwi Department of Community Development 6/3/2021 AMMONE BEMBRY 7717 DETROIT AVE SW SEATTLE, WA 98106 RE: Permit No. M19-0207 SABEY IGW - B HQ RENOVATIONS 12201 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Nora Gierloff, .Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/8/2021. Based on the above, you are hereby advised to: 1) Login to the City of Tukwila's Online Portal https://tulcw-egov.aspgov.com/BP/index.html to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/8/2021, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Shana Markstrom Permit Technician File No: M19-0207 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 iDERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0207 DATE: 12/18/19 PROJECT NAME: SABEY IGW - B HQ RENOVATIONS SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works OA Fire .Prevention Structural Planning Division Pen -nit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/19/19 Structural Review Required REVIEWER'S INIT ALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues Approved with Conditions DUE DATE: 01/16/20 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff initials: 12/18/2013 Labor &Induslries (hms,ilini.„.,1„) Contractors MACDONALD/MILLER FAC SOL INC Owner or tradesperson Principals SIMONDS, DERRICK R, PRESIDENT WEBSTER, MARK E, VICE PRESIDENT GEBHARDT, STEPHANIE WETTACH, TREASURER HOEL, STEPHANIE W, MEMBER SIGMUND, FREDRIC, PRESIDENT (End: 01/04/2011) LOVELY, STEVE C, VICE PRESIDENT (End: 01/04/2011) HACK, RICHARD, SECRETARY (End: 01/04/2011) KOPET, TYLER, TREASURER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF EXECUTIVE OFFICER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF OPERATING OFFICER (End: 01/04/2011) GOUGH, DAVID ANTHONY, DIRECTOR (End: 08/29/2014) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No, 602 254 260 PO BOX 47983 SEATTLE, WA 98106 206-768-4180 KING County Business type Corporation Governing persons FREDRIC J SIGMUND STEVE C LOVELY; TYLER C KOPET; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. MACDOES980RU Effective — expiration 12/31/2002— 01/04/2021 Bond LIBERTY MUTUAL INS CO Bond account no. 023006951 $12,000.00 Received by L&I Effective date \Shta\73192847TM0_O1.dwg csi UNIT : AC-101 VARIABLE VOLUME OPTION 2: FAN SYSTEM BHP SYSTEM DESIGNED FOR COOLING HP 5 CFMS x 0,0013 + A 14,32 515,000 x 0.0013 + 1.815 14.32 5 21,315 A= SUM OF[PD "CFMD /4131] A = [0.5 x 15,000 / 4131] A=1.815 "FAN HORSE POWER SHALL NOT EXCEED 90% OF THE ALLOWABLE "FAN SYSTEM BHP" TABLE C403.2.11.1(1) FAN POWER LIMITATION LIMIT CONSTANT VOLUME VARIABLE VOLUME OPTION 1: FAN SYSTEM ALLOWABLE MOTOR NAMEPLATE HP NAMEPLATE HP OPTION 2: FAN SYSTEM BHP HP 5 CFMS * 0.0011 HP 5 CFMS * 0.0015 ALLOWABLE FAN BHP 5 CFMS * 0.00094+A BHP 5 CFMS * 0.0013 + A SYSTEM BHP A= SUM OF[PD "CFMD /4131] PD = EACH APPLICABLE PRESSURE DROP ADJUSTMENT FROM TABLE C403.2.10.1(2) IN CUBIC FEET PER MINUTE. CFMD = THE DESIGN AIRFLOW THROUGH EACH APPLICABLE DEVICE FROM TABLE C403.2.10.1(2) IN CUBIC FEET PER MINUTE PD USED = 0.5 INCH w.c BASED ON TABLE C403.2.11.1(2) PARTICULATE FILTRATION CREDIT: MERV 9-12 UNIT WT NO, AREA SERVED MFG & MODEL NO. TYPE CFM ESP RPM FLA HP VOLT/PH : BDD LBS NOTES EF-201 LEVEL 2 LOCKER ROOMS GREENHECKG-095-VG DIRECT 710 05 ! 1634 X 116 115/1 NO 38 : NEW, 1-5 NOTES: 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. 2. MOTOR STARTER BY ELECTRICAL CONTRACTOR. 3. INSTALL ON FACTORY PROVIDED CURB. 4. WEATHERHOOD. 5. MOTORIZED POSITIVE CLOSER DAMPER \ 4MIN 24ID z N 160 z .H 4MIN y \ 1SD-1 SHAFT FROM 3RD LEVEL FROM 2ND N.T.S. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK, 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES, 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2015 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2015 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS - DUCT WRAP, WHERE INDICATED, SHALL BE 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER. - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM. - DUCT BOARD, WHERE INDICATED, SHALL BE 1' RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT. -SUPPLY DUCT WHICH CONVEYS SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F WHEN LOCATED IN CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF R-3.3, WHEN LOCATED IN UNCONDITIONED SPACE R-6 AND WHEN LOCATED OUTSIDE THE BUILDING R-8 (CLIMATE ZONE 4) OR R-12 (CLIMATE ZONE 5) PER WSEC C403,2.8.2, -OUTSIDE AIR DUCT INSULATION SHALL MATCH BUILDING ENVELOPE INSULATION VALUES UNLESS SERVING INDIVIDUAL SUPPLY AIR UNITS WITH LESS THAN 2800 CFM OF TOTAL SUPPLY AIR CAPACITY, PROVIDED THESE ARE INSULATED TO R-7 MINIMUM PER WSEC C403.2.8.1. 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2015 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2015 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2015 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRESMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2015 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. BAS TO MONITOR FIRE ALARM CONTROL PANEL AND SHUT DOWN ALL FAN TERMINAL UNITS DURING ANY BUILDING FIRE ALARM EVENT, IN ACCORDANCE WITH IMC 606.2.2. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18'. 12. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, 13. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 14. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 15. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS AND SECTION C408. 16. ACOMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 17. SHAFT WALLS CONSTRUCTED TO SUPPORT AIR MOVEMENT FOR RETURN AIR SYSTEMS AND STAIR & ELEVATOR PRESSSURIZATION SYSTEMS SHALL BE CONSTRUCTED TO THE FOLLOWING STANDARDS: A. SHAFTS (RATED FOR MAXIMUM 2' WC) SHALL BE CONSTRUCTED TO WITHSTAND 15 PSF LOADING WITH A DEFLECTION OF U360 (UNO). 8. SHAFTS SHALL BE SEALED SUBSTANTIALLY AIR -TIGHT USING THE CRITERIA FROM THE INTERNATIONAL BUILDING CODE: 1. SECTION 715.8 FIRE RESISTANT JOINT SYSTEMS IN SMOKE BARRIERS: LEAKAGE SHALL NOT EXCEED 5 CFM PER LINEAR FOOT OF JOINT AT 0.3" WC. 2. SECTION 909.5 SMOKE BARRIER CONSTRUCTION FOR INTERIOR EXIT STAIRWAYS AND EXIT PASSAGEWAYS: MAXIMUM ALLOWABLE LEAKAGE AREA PER SHAFT SHALL NOT EXCEED (0.00035 SF/SF) C. STAIR AND ELEVATOR PRESSURIZATION SHAFTS SHALL BE PRESSURE TESTED DURING COMMISIONING. CONTRACTOR SHALL MAKE MODIFCATIONS TO INSTALLATION UNTIL SHAFT IS IN COMPLIANCE. 18. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE FATES AT 1" W.G. (PER AMCA STANDARD 500D) MOTORIZED DAMPERS: 4 CFM/S.F. GRAVITY DAMPERS: 20CFMIS.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 19. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C403.2.4.3 EXCEPT AS ALLOWED BY WSEC. TAG FSD-1 DESCRIPTION -POWERED NOTES 1 12 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3-V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. I- VOLUME DAMPER: SHOP FABRICATED, WILOCKING QUADRANT. NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN/CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. DAMPER FAILS CLOSED TAG 1,2 FSD-2 DESCRIPTION -NON POWERED 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120 VACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. NOTES 1,2 @)4145 OB SIZE CFM O SIZE CFM O DCFM MANUFACTURER & MODEL SIZE NUMBER SHOEMAKER HL SERIES TITUS 300RS SHOEMAKER 904 METAL EGGCRATE METAL EGGCRATE SHOEMAKER 905 AS NOTED AS NOTED AS NOTED AS NOTED AS NOTED 'TYPE ARCHITECTURAL HIGH VOLUME T•BAR PLAQUE DIFFUSER BATHROOM EXHAUST GRILLE DOUBLE DEFLECTION SIDEWALL DIFFUSER T-BAR LAY -IN METAL EGGCRATE T-BAR LAY -IN METAL EGGCRATE AS NOTED ; TRANSFER AIR GRILLE WALL MOUNT NOTES MOUNT WITH TITUS TRM RING TITLE PROJECT ENGINEER ACCOUNT MANAGER SHEET METAL SUPERINTENDENT SHEET METAL FOREMAN SSP AIR BALANCE FOREMAN SSP REFRIGERATION FOREMAN SSP ELECTRICAL FOREMAN SSP ELECTRICAL FOREMAN NAME MATT CAVINESS STEVE FLINK NATHAN WAAGEN TIM FELTON RON LANDBERG DEAN GRASSER GREG SUKRAW CLAYTON PARKER COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER EMAIL 206-768.3858 MATT.CAVINESS@MACMILLER.COM 253-680-3172 STEVE.FLINK@MACMILLERCOM 206-786-8157 NATHAN.WAAGEN@MACMILLER.COM 206-407-2692 TIM.FELTON@MACMILLERCOM 206-571-2661 RON.LANDBERG@MACMILLER.COM 206-768-4270 DEAN.GRASSER@MACMILLER,COM 206-768-4078 GREG.SUKRAW@MACMILLER.COM 206-760-4234 CLAYTON.PARKER@MACMILLER.COM UNIT NO. AC-201 TRANE MODEL NO. YCD4S0 --- NOM TONS 40.0 GAS HEAT MBH INPUT 350 FAN OSA EER/ OUTPUT ! CFM ESP HP CFM SEER 280.00 15000 a 2.0 15.0 � VARIES I 11/14.7 NOTES: 1. DISCONNECT MID MOTOR STARTERS SIZED AND PROVIDED BY ELECTRICAL CONTRACTOR 2. PROVIDED WITH THESE FACTORY ACCESSORIES: - 100% POWER EXHAUST - ULTRA LOW LEAK 100% OSA ECONOMIZER PER WSEC 403.3.3.1 - SUPPLY AIR VFD FOR VAV APPLICATIONS - FACTORY AIR FLOW MEASURING STATION FOR BOTH OUTSIDE AIR AND SUPPLY AIR - DDC CONTROLS INTERFACE - BACNET MSTP - ECONOMIZER FAULT DETECTION AND DIAGNOSTICS - 4 STAGES OF MECHANICAL COOLING PER WSEC TABLE G403.3.1 - INTEGRATED ECONOMIZER CONTROL 3. PROVIDE FACTORY ROOF CURB, AND ATTACH PER STRUCTURAL ENGINEER'S REPORT ELECTRICAL VOLT/PH - MCA LBS 1 NOTES 460/3 103,25 6086 1-3 UNIT NO. VAV-201 VAV-202 VAV-203 VAV-204 VAV-205 VAV-206 VAV-312 MFG & MODEL NO TRANE-VPEF14 TRANE-VPEF08 TRANE-VPEF10 TRANE-VPEF10_ TRANE-VPEF10 TRANE-VPEF10 TRANE-VPER12 INLET SIZE 14 8 10 10 10 10 12 VALVE CFM HEATER FAN MAX MIN KW DT CFM VOLT/PH i STGS HP ' VOLTIPH 1800 1 325 12.5 24.58 645 1 277/1 2 1/2 277/1 560 --- 350 I 4,5 25.28 ' 225 27711 2 , 1/3 277/1 1250 1 250 10 25.16 505 ' 27711 2 1/3 920 185 7.5 1 25.64 I 370 1150 : 235 9 ' 24.62 I A65 1095 215 9 25.85 435 1675 335 13 2441 870 ' NOTES: 1. DISCONNECT BY ELECTRICAL. 2. PARALLEL FAN POWERED TERMINAL UNIT WITH HEAT -, SIZE AS LISTED, PRESSURE INDEPENDENT, FACTORY OPTIONS INCLUDE: - EXTENDED DAMPER 1/2" DIAM. SHAFT - FACTORY INSTALLED 1" THROW -AWAY FILTERS - CONTROLS BY OTHERS - FACTORY PROVIDE WIRING HARNESS WITH LOW VOLTAGE INTERLOCK CONDUCTORS EXTENDED FROM HIGH VOLTAGE CABINET TO LOW VOLTAGE CONTROLS CABINET. -1' MATT -FACED UNIT INSULATION - ECM MOTOR WITH VARIABLE SPEED FAN CONTROL. - 24V TRANSFORMER, 50 VA MIN RATING - HEAT STAGING & FAN CONTROL THROUGH FACTORY WIRED RELAYS -AUTO RESET 120°F HIGH LIMIT TSTAT COMBINED TEMPERATURE STAT AND CO2 STAT ACCORDING TO WSEC C403.3 - NON MAGNETIC QUIET ACTING HEATER CONTACTOR 3. COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, PRESSURE INDEPENDENT, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: -1"MATT-FACED UNIT INSULATION - 24V TRANSFORMER, 50 VA MIN RATING NOTE TO ELECTRICAL: - 460V/3PH TERMINAL UNITS REQUIRE A FOUR WIRE POWER FEED IN ORDER TO SUPPLY 277V/1PH POWER TO THE FAN MOTOR. 277/1 27711 277/1 27711 _ 1/3_ 1/3 1/3 1/3 277/1 277/1 277/1 277/1 277/1 �tiDr : 4,"" tAL - r1m UNIT NO. VAV-207 ' VAV-208 VAV-209 VAV-210 VAV-211 . ...................:. . VAV-213 INLET VALVE CFM MFG & MODEL NO. , SIZE MAX I MIN 240 I 50 580 115 6 405 I 80 TRANE VCCF05 TRANE VCCF08 TRANEVCCF06 TRANEVCCFOB TRANE VCCF08 TRANE VCCF05 I 575 115 545 1 110 255 50 NOTES: 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. 2. 24V DAMPER ACTUATOR AND CONTROL WIRING BY CONTROLS CONTRACTOR. 3. CONTROLS CONTRACTOR TO PROVIDE COMBINATION ROOM TEMPERATURE AND CO2 SENSOR HYDRONIC HEAT MBH DT GPM #COILS PD (FT) CONTROL DDC DDC DDC DDC DDC DDC NOTES COMMISSIONING IN COMPLIANCE WITH 2015 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE REQUIRED FOR ALL NEW SYSTEMS OR MODIFIED PORTIONS OF SYSTEMS UNLESS THE SYSTEMS MEET ONE OR MORE OF THE FOLLOWING EXCEPTIONS: EXCEPTION Al: AIR COOLED CONSTANT VOLUME PACKAGED EQUIPMENT WITH COOLING CAPACITY OF 11.25-TONS OR LESS. EXCEPTION A2: AIR COOLED CONSTANT VOLUME SPLIT SYSTEMS WITH COOLING CAPACITY OF 7-TONS OR LESS. EXCEPTION A3: HEATING ONLY SYSTEMS WHICH HAVE ACAPACITY OF LESS THAN 1,000 CFM OR HAVE A MINIMUM OUTSIDE AIR SUPPLY OF LESS THAN 30%OF THE TOTAL AIR CIRCULATION. EXCEPTION B: SYSTEMS NOT REQUIRED TO HAVE AN AIR ECONOMIZER. EXCEPTION C: SYSTEMS WITH A BUILDING TOTAL COOLING CAPACITY OF LESS THAN 40-TONS AND HEATING CAPACITY LESS THAN 600,000 BTU/1-1. THE COMMISSIONING PROCESS SHALL BE REQUIRED BY 2015 WSEC SECTION C408 AND INCLUDE: 1) A COMMISSIONING PLAN; 2) SYSTEMS TEST AND BALANCE; 3) HVAC EQUIPMENT AND HVAC CONTROLS FUNCTIONAL TESTING; 4) MANUALS, RECORD DOCUMENTS, AND TRAINING; AND 5) COMMISSIONING REPORT COMMISSIONING DOCUMENTATION SHALL BE AS REQUIRED IN 2015 WSEC SECTION C408.1.3 AND INCLUDE 1) RECORO LNCUMENTS; 2) OPERATION AND MAINTENANCE MANUALS; 3) SYSTEM BALANCING REPORT; 4)A FINAL COMMISSIONING REPORT. RECORD DRAWINGS THAT ARE UPDATED AND REDLINED TO INDICATE THE SYSTEM AND EQUIPMENT AS INSTALLED SHALL 8E PROVIDED ACCORDING TO 2015 WSEC SECTION C408.1.3.1 A FINAL COMMISSIONING REPORT SHALL BE AS REQUIRED BY 2015 WSEC SECTION C408.1.3.4 AND INCLUDE 1) RESULTS OF FUNCTIONAL PERFORMANCE TESTS; 2) DESCRIPTION OF DEFICIENCES FOUND DURING TESTING AND DETAILS OF CORRECTIVE MEASURES; 3) FUNCTIONAL PERFORMANCE TEST PROCEDURES SYSTEMS OPERATIONS TRAINING SHALL BE PROVIDED AS REQUIRED BY 2015 WSEC SECTION C408.1.4 AND INCLUDE I) REVIEW OF SYSTEMS DOCUMENTATION; 2) HANDS-ON DEMONSTRATION OF MAINTENANCE AND OPERATION; AND 3) TRAINING COMPLETION REPORT INSTALL NEW DX ROOFTOP UNIT WITH PROPANE HEAT. INSTALL MEDIUM PRESSURE DUCTWORK AS SHOWN, ALONG WTH (10) VAV BOXES, LOW PRESSURE DUCTWORK, AND (42) DIFFUSERS TO SERVE 2ND FLOOR OFFICE AREA. NEW VAV'S SHALL COMPLY WITH HIGH PERFORMANCE VAV CRITERIA AS SHOWN IR THE WSEC SECTION 403. THE ROOFTOP UNIT PROVIDED EXCEEDS REQUIRED EFFICIENCY AND HAS BEEN DEEMED APPROPRIATE FOR THE APPLICATION BY THE CODE OFFICIAL (EMAIL AT•ACHED). RECEIVED CITY OF TUKWILA A DEC 182019 PERMIT CENTER PARCEL NUMBER:092304-9120 BUILDING NAME: INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD, 98188 LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89-1635 E 100 FT TH S 24-13-53 E 969.61 FT TO POINT )F BEGINNING TH N 65-08-07 E 58.17 FT TH N 63.32.48 E 62.13 FT TH S 22.47-01 E 21.44 FT TH N 65-30-25 E 199.33 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1-K APPROVED JUL123, 1957 TH FOLLOWING SAID WLY RAN LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT, CENTER BEARING S 85-44-51 W, THRU C/A OF 1-16-30 DISTANCE OF 62.42 FT TH FOLLOWING SAID WLY RN/ LINE N 67-01-2-E 10 FT TH FOLLOWING SAID WLY RAY LINE ALONG ARC OF 2815 FOOET RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 67-01-21 W THRU C/A OF 8-31-21 DISTANCE OF 320.45 FT TH S 7332-42 W 16.58 FT TH S 71-35-51 W 61.$ FT TH N 78.38-58 W 7,83 FT TH S 75-53 44 W 106.07 FT TH N 05-01-10 W 18.41 FT TH S 82-22-27 W 64.93 FT TH S 63-55-24 W 58.16 FT TH N 24-13-53 W 334.22 FT TO POINT OF BEGINNING - LOT B OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMEN NO L98.0033 RECORDING NO9810059013 M19-0207 N-OZO7 SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing LJ Gas Piping City of Tukwila BUILDING DIVISION 07') h O ¢ 0 Nr CO u- • E "' mKOLL- N 10 0. 0 CO U. N o u)OOG( 2 iM n � O U1 6 ✓ c • O L 5-d I I I I I I I I I I I I I I I I I I I I PERMIT SET I I I I I I I< Z 0 0 z V m J d 1-7 a �d Z W ,p - ;To. Q W W Q W W H J VJ cc,j Z U J REVISIONS: W 0 REVISIONS: ISSUED FOR PERM ENGINEER: LAST REVISED: M CAVINESS 12-18-19 CHECKED BY: DATE PLOTTED: K JOHANSON 12-18-19 CAD: ISSUE DATE: M HAGBERG DRAWING NUMBER: 0-1542-73192847-000 SHEET NUMBER: .JAN 03 2020 City of Tukwila BUILDING DIVISION VAV AIR HANDLING UNIT SERVES: OFFICE SPACE - LEVEL 2 CONTROL TYPE: DDC OCCUPIED HOURS: 7:OOAM TO 6:00 PM MONDAY THROUGH FRIDAY. SUBJECT TO HOLIDAY AND EVENT SCHEDULING COOLING DISCHARGE AIR TEMPERATURE: RESET FROM 65° TO 55° STATIC PRESSURE SETPOINT: RESET FROM .5 TO 2.0 (ADJ) DESCRIPTION: HIGH EFFICIENCY VAV ROOFTOP COOLING UNIT OCCUPIED MODE: DURING THE OCCUPIED HOURS, THE SUPPLY FAN RUNS AND IS MODULATED TO MAINTAIN THE DUCT STATIC PRESSURE SETPOINT. DUCT STATIC PRESSURE IS RESET USING A TRIM AND RESPOND SEQUENCE TO MAINTAIN 10% (ADJ) OF THE BOXES IN AN AIR STARVED STATE. THE ECONOMIZER AND MECHANICAL COOLING ARE STAGED AS NEEDED TO MAINTAIN THE RESETTING DISCHARGE AIR TEMPERATURE SETPOINT. ECONOMIZER IS USED AS THE FIRST STAGE OF COOLING AND MECHANICAL COOLING IS USED IN CONJUNCTION WITH ECONOMIZER UNTIL THE OUTSIDE AIR TEMPERATURE IS NO LONGER SUITABLE FOR USE IN ECONOMIZER. WHEN THE OUTSIDE AIR IS NOT SUITABLE FOR ECONOMIZER USE, THE OSA DAMPER IS MODULATED TO THE MINIMUM OUTSIDE AIR FLOW SETPOINT AS MEASURED AT THE AFMS. MINIMUM POSITION IS ADJUSTED BY THE DDC SYSTEM TO MAINTAIN TOTAL OUTSIDE AIR NEEDED FOR SPACE VENTILATION AS CALCULATED BY MONITORING THE CO2 AND OCCUPANCY SENSORS AT THE ZONE LEVEL. UNOCCUPIED MODE: THE SUPPLY FAN IS OFF, AND THE OUTSIDE AIR DAMPER IS CLOSED. MECHANICAL COOLING IS DISABLED NIGHT SETBACK: NIGHT SETBACK HEATING IS ACCOMPLISHED AT THE ZONE LEVEL. SEE VAV SEQUENCE BELOW NIGHT SETUP: WHEN THE DDC SYSTEM MEASURES A COOLING DEMAND (AVERAGE OF ALL BOXES SERVED BY THIS UNIT) GREATER THAN 35%(ADJ), THE UNIT IS ENABLED AND OPERATES AS IN THE OCCUPIED MODE TO PROVIDE NIGHT SET UP COOLING TO THE VAV BOXES. MORNING WARMUP: THE BMS MONITORS THE OUTSIDE AIR TEMPERATURE AND DETERMINES A SUITABLE START TIME FOR MORNING WARM UP. THE AHU REMAINS OFF WITH THE OUTSIDE AIR DAMPERS CLOSED UNTIL THE AVERAGE SPACE TEMPERATURE OF THE FAN POWERED VAV BOXES REACHES THE ROOM TEMPERATURE SET POINT. WHEN THE AVERAGE ROOM TEMP SETPOINT IS REACHED, THE UNIT FAN IS STARTED, (OSA DAMPER CLOSED) AND AIR IS RECIRCULATED THROUGH THE SPACE UNITL THE INTERIOR (SQUEEZE BOX) ZONES ARE AT TEMPERATURE, SEE VAV SEQUENCE FOR FURTHER INFORMATION. MANUAL MODE: THE DDC SYSTEM SHALL INCLUDE A MANUAL MODE SOFTWARE SWITCH WHERE THE OPERATING AGENT CAN TOGGLE THE OPERATION OF FANS COMPRESSORS AND ECONOMIZER DAMPERS TO VERIFY OPERATION. FAULT DETECTION AND DIAGNOSTICS: IN ACCORDANCE WITH THE HIGH EFFICIENCY VAV CODE, FAULT DETECTION AND DIAGNOSTICS SHALL DETECT AND REPORT TEMPERATURE SENSOR FAILURES, ECONOMIZER ACTIVITY WHEN THE OSA IS NOT SUITABLE FOR ECONOMIZER, NO ECONOMIZER ACTIVITY WHEN THE OUTSIDE AIR IS SUITABLE FOR USE, AND OUTSIDE AIR OR RETURN AIR DAMPER FAILURE. DISPLAY, TRENDING AND ALARM: - MODE - FREE COOLING AVAILABLE - DISCHARGE AIR TEMPERATURE - ECONOMIZER STATUS (COMMANDED) - OSA TEMPERATURE - COMPRESSOR STATUS(COMMANDED) - RETURN AIR TEMPERATURE - HEATING STAGE STATUS MAKE AVILABLE FOR FUTURE IF DESIRED - MIXED AIR TEMPERATURE - COOLING STAGE STATUS - OSA DAMPER POSITON (COMMANDED) - CALCULATED OSA REQUIREMENT - OSA TOTAL AIRFLOW (AFMS) - AHU FAULT STATUS - OSA DAMPER FAILURE - RETURN AIR DAMPER FAILURE - MIXED AIR LOW LIMIT STATUS PARALLEL FAN POWERED VAV SERVES: OFFICE SPACE PERIMETER ZONES - LEVEL 2 CONTROL TYPE: DDC OCCUPIED HOURS: 7:OOAM TO 6:00 PM MONDAY THROUGH FRIDAY. SUBJECT TO HOLIDAY AND EVENT SCHEDULING OCCUPIED COOLING SETPOINT:75° (ADJ.) UNOCCUPIED COOLING SETPOINT:85° (ADJ.) OCCUPIED HEATING SETPOINT: 70°(ADJ.) UNOCCUPIED HEATING SETPOINT: 65"(ADJ.) DESCRIPTION: HIGH EFFICIENCY PARALLEL FAN POWERED VAV BOX WITH ELECTRIC HEAT OCCUPIED MODE: THE PRIMARY AIR DAMPER IS MODULATED BETWEEN THE MINIMUM AND MAXIMUM CFM SETPOINTS TO MAINTAIN THE ZONE COOLING SETPOINT. WHEN IN THE DEADBAND MODE, THE MINIMUM CFM IS REDUCED TO THE DEMAND CONTROL VENTILATION SETPOINT (SEE DCV SEQUENCE BELOW). HEAT AND PARALLEL FAN ARE USED TO MAINTAIN THE ZONE HEATING SETPOINT. WHEN IN THE HEATING MODE, THE FAN SPEED IS VARIED ALONG WITH THE HEATING DEMAND, AND THE SCR HEAT IS MODULATED TO MAINTIAN A DISCHARGE AIR TEMPERATURE. MINIMUM FAN SPEED CAN BE NO MORE THAN 66% OF THE HEATING MAX SETPOINT. UNOCCUPIED MODE: THE PARALLEL FAN IS OFF, AND THE PRIMARY AIR DAMPER IS CLOSED. HEAT IS DISABLED NIGHT SETBACK: A REDUCED HEATING SETPOINT IS USED DURING THE UNOCCUPIED HOURS. WHEN THE ZONE TEMPERATURE FALLS BELOW THE NIGHT SETBACK TEMPERATURE, THE PARALLEL FAN AND HEAT CYCLE AS NEEDED TO BRING THE ZONE UP TO THE NIGHT SETBACK HEATING TEMPERATURE. THE PRIMARY AIR VALVE IS CLOSED DURING THIS POSTURE. WHEN THE ZONE TEMPERATURE SETPOINT HAS BEEN REACHED, THE BOX RETURNS TO THE UNOCCUPIED POSTURE NIGHT SETUP: AN INCREASED COOLING SETPOINT IS USED DURING THE UNOCCUPIED HOURS. WHEN THE ZONE TEMPERATURE RISES ABOVE THE NIGHT SETUP TEMPERATURE, THE PRIMARY AIR DAMPER IS MODULATED AS NEEDED TO BRING THE ZONE DOWN TO THE NIGHT SETUP COOLING TEMPERATURE. WHEN THE TEMPERATURE SETPOINT HAS BEEN REACHED, THE BOX RETURNS TO THE UNOCCUPIED POSTURE MORNING WARM-UP: THE BMS MONITORS THE OUTSIDE AIR TEMPERATURE ANS DETERMINES AN APPOPRIATE START TIME FOR MORNING WARM UP. WHEN DEEMED APPROPRIATE, THE PARALLEL FAN IS STARTED ALONG WITH ELECTRIC HEAT TO MAINTAIN A DISCHARGE AIR TEMPERATURE OF 95°F(ADJ) AND A FAN SPEED OF 75%(ADJ.) TO BRING THE SPACE TEMPERATURE UP TO THE OCCUPIED SETPOINT. ONCE THE OCCUPIED SETPOINT IS REACHED, THE FAN AND HEAT ARE CYCLED TO MAINTAIN THE SETPOINT TEMPERATURE. THE UNIT US SWITCHED TO THE OCCUPIED MODE WHEN THE OCCUPIED PERIOD BEGINS. DEMAND CONTROL VENTILATION (DCV): ZONES (SEE DRAWING) THAT USE DEMAND CONTROL VENTILATION WILL HAVE A CO2 SENSOR, AND POSSIBLY AN OCCUPANCY SENSOR TO COMPLY WITH THE DEMAND CONTROL VENTILATION CODE. WHEN THE OCCUPANCY SENSOR DETERMINES THAT A ZONE IS UNOCCUPIED (NO INFRARED MOTION DETECTION FOR A PERIOD OF 10 MINUTES(ADJ)), THE ROOM TEMPERATURE SETPOINT IS RESET UP 5°(IN THE COOLING POSTURE) AND DOWN 5° (IN THE HEATING POSTURE) FROM THE OCCUPIED SETPOINT, AND THE DEADBAND CFM IS SET TO "0". WHEN THE ROOM IS OCCUPIED AND IN EITHER THE HEATING OR DEADBAND POSTURE, AND THE ROOM CO2 MINIMUM CFM. AS THE CO2 READING INCREASES BETWEEN 800 AND 1100 PPM, THE PRIMARY AIR DAMPER IS MODULATED BETWEEN THE ALTERNATE MINIMUM AND DESIGN MINIMUM SENSOR IS READING 700 PPM OR BELOW, THE PRIMARY AIR VALVE IS SET TO THE ALTERNATE SETPOINTS. THE ALTERNATE MINIMUM IS SET AT .06 CFM/SF (CALCULATED BY AREA SERVED) OR BOX MANUFACTURER'S MINIMUM CFM, WHICHEVER IS GREATER. FAULT DETECTION AND DIAGNOSTICS: YAWS SHALL BE CONFIGURED TO REPORT AND TREND WHEN A ZONE IS DRIVING THE DUCT STATIC PRESSURE RESET TO ITS HIGHEST STATIC PRESSURE SETPOINT, AND WHEN A ZONE IS CAUSING THE SUPPLY AIR TEMPERATURE TO BE RESET TO ITS LOWEST TEMPERATURE SETPOINT. VAV'S SHALL ALSO SELF TEST THE MINIMUM AND MAXIMUM PRIMARY AIR DAMPER POSITION AND REPORT IF THE CFM IS GREATER THAN "0" WHEN CLOSED, OR GREATER THAN 10% OFF OF THE DESIGN CFM WHEN IN THE MAXIMUM SETPOINT POSITION DISPLAY, TRENDING AND ALARM: MODE - ZONE TEMPERATURE SETPOINT - ZONE TEMPERATURE (ACTUAL) -OCCUPANCYSENSORSTATUS - FAN SPEED (SETPOINT) - ZONE DRIVING STATIC PRESSURE RESET - ZONE DRIVING DAT RESET - DISCHARGE AIR TEMPERATURE - MIXED AIR TEMPERATURE - SCR HEAT PERCENTAGE -AHU MODE - FAILED INLET DAMPER ACTUATOR OR FLOW STATION SINGLE DUCT VAV SERVES: OFFICE SPACE INTERIOR ZONES - LEVEL 2 CONTROL TYPE: DDC OCCUPIED HOURS: 7:00AM TO 6:00 PM MONDAY THROUGH FRIDAY. SUBJECT TO HOLIDAY AND EVENT SCHEDULING OCCUPIED COOLING SETPOINT: 75° (ADJ.) UNOCCUPIED COOLING SETPOINT: 85° (ADJ.) OCCUPIED HEATING SETPOINT: 70°(ADJ.) UNOCCUPIED HEATING SETPOINT: 65°(ADJ.) DESCRIPTION: HIGH EFFICIENCY SINGLE DUCT VAV BOX OCCUPIED MODE: THE PRIMARY AIR DAMPER IS MODULATED BETWEEN THE MINIMUM AND MAXIMUM CFM SETPOINTS TO MAINTAIN THE ZONE COOLING SETPOINT. WHEN IN THE DEADBAND MODE, THE MINIMUM CFM IS REDUCED TO THE DEMAND CONTROL VENTILATION SETPOINT (SEE DCV SEQUENCE BELOW). UNOCCUPIED MODE: THE PRIMARY AIR DAMPER IS CLOSED. NIGHT SETUP: AN INCREASED COOLING SETPOINT IS USED DURING THE UNOCCUPIED HOURS. WHEN THE ZONE TEMPERATURE RISES ABOVE THE NIGHT SETUP TEMPERATURE, THE PRIMARY AIR DAMPER IS MODULATED AS NEEDED TO BRING THE ZONE DOWN TO THE NIGHT SETUP COOLING TEMPERATURE. WHEN THE TEMPERATURE SETPOINT HAS BEEN REACHED, THE BOX RETURNS TO THE UNOCCUPIED POSTURE DEMAND CONTROL VENTILATION (DCV): ZONES (SEE DRAWING) THAT USE DEMAND CONTROL VENTILATION WILL HAVE A CO2 SENSOR, AND POSSIBLY AN OCCUPANCY SENSOR TO COMPLY WITH THE DEMAND CONTROL VENTILATION CODE. WHEN THE OCCUPANCY SENSOR DETERMINES THAT A ZONE IS UNOCCUPIED (NO INFRARED MOTION DETECTION FOR A PERIOD OF 10 MINUTES(ADJ)), THE ROOM TEMPERATURE SETPOINT IS RESET UP 5° FROM THE OCCUPIED SETPOINT, AND THE DEADBAND CFM IS SET TO "0". WHEN THE ROOM IS OCCUPIED AND THE DEADBAND POSTURE, AND THE ROOM CO2 SENSOR IS READING 700 PPM OR BELOW, THE PRIMARY AIR VALVE IS SET TO THE ALTERNATE MINIMUM CFM. AS THE CO2 READING INCREASES BETWEEN 800 AND 1100 PPM, THE PRIMARY AIR DAMPER IS MODULATED BETWEEN THE ALTERNATE MINIMUM AND DESIGN MINIMUM SETPOINTS. THE ALTERNATE MINIMUM IS SET AT .06 CFM/SF (CALCULATED BY AREA SERVED) OR BOX MANUFACTURERS MINIMUM CFM, WHICHEVER IS GREATER. MORNING WARM-UP: THE BMS MONITORS THE AVERAGE SPACE TEMPERATURE OF THE FAN POWERED VAV ZONES. WHEN MORE THAN 80%OF THE FAN POWERED ZONES HAVE REACHED THEIR ROOM TEMPERATURE SETPOINT, THE SINGLE DUCT BOXES MODULATE THEIR PRIMARY AIR DAMPER BETWEEN MINIMUM AND MAXIMUM POSITION TO (USING A REVERSE DAMPER LOGIC) UNTIL THE ROOM TEMPERATURE SETPOINT HAS BEEN REACHED. THE UNITS REMAIN IN THE MORNING WARM UP POSTURE UNITL OCCUPIED PERIOD BEGINS. FAULT DETECTION AND DIAGNOSTICS: VAV'S SHALL BE CONFIGURED TO REPORT AND TREND WHEN A ZONE IS DRIVING THE DUCT STATIC PRESSURE RESET TO ITS HIGHEST STATIC PRESSURE SETPOINT, AND WHEN A ZONE IS CAUSING THE SUPPLY AIR TEMPERATURE TO BE RESET TO ITS LOWEST TEMPERATURE SETPOINT. VAV'S SHALL ALSO SELF TEST THE MINIMUM AND MAXIMUM PRIMARY AIR DAMPER POSITION AND REPORT IF THE CFM IS GREATER THAN "0" WHEN CLOSED, OR GREATER THAN 10% OFF OF THE DESIGN CFM WHEN IN THE MAXIMUM SETPOINT POSITION DISPLAY, TRENDING AND ALARM: -MODE - ZONE TEMPERATURE SETPOINT - ZONE DRIVING STATIC PRESSURE RESET - ZONE TEMPERATURE (ACTUAL) - ZONE DRIVING DAT RESET - OCCUPANCY SENSOR STATUS - AHU MODE - FAILED INLET DAMPER ACTUATOR OR FLOW STATION ABBV AC.......... AFF AHU AL HAS BDD BI B0D BOTT BTU BTUH CAT1 CAT4 CFM CPVC DB DDC DEMO DIFF DMPR DN EAT EC EER EF ELEV ESP EWT FULL NAME AIR CONDITIONING UNIT ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINUM BUILDING AUTOMATION SYSTEM BACK DRAFT DAMPER BLACK IRON BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR CATEGORY ONE VENT CATEGORY FOUR VENT CUBIC FEET PER MINUTE CPVC MATERIAL DUCTBOARD DIRECT DIGITAL CONTROLS DEMOLISH DIFFUSER DAMPER DOWN EXISTING ENTERING AIR TEMPERATURE EGGCRATE ENERGY EFFICIENCY RATIO EXHAUST FAN ELEVATION EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE ABBY FCU FD FLA FOB FOT FSD GALV GC GENX GLVNL GPM GREASE GWB HP HVAC HX ID LAT LBS LWT MAT MBH MCA MD MIN M-M NC NIC NO FULL NAME FAN COIL UNIT FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GALVANIZED GENERAL CONTRACTOR GENERATOR EXHAUST GALVANNEAL GALLONS PER MINUTE GREASE DUCT GYPSUM WALL BOARD HORSE POWER, HEAT PUMP HEATING, VENTILATION AND AIR COND. HEAT EXCHANGER INSIDE DIMENSION LEAVING AIR TEMPERATURE POUNDS LEAVING WATER TEMPERATURE MIXED AIR TEMPERATURE ONE THOUSAND BTUH MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MACDONALD-MILLER NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN ABBV FULL NAME NOM NOMINAL NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PVC POLYVINYL CHLORIDE REQ'D REQUIRED RPBA REDUCED PRESSURE BACKFLOW ASSY RTU ROOFTOP UNIT SA SUPPLY AIR SD SMOKE DAMPER SL SOUND LINED SM SHEET METAL SP STATIC PRESSURE SS STAINLESS STEEL SUSP SUSPENDED T THERMOSTAT TOD TOP OF DUCT TV TURNING VANES TYP TYPICAL UNO UNLESS NOTED OTHERWISE VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VFD VARIABLE FREQUENCY DRIVE W DUCT INSULATION WRAP WI WITH WELD WELDED 0 VOLTAGE PHASE 8 DUCT DIAMETER DESCRIPTION BARE RECTANGULAR SHEETMETAL SOUNDLINE SHEETMETAL (GENERAL NOTES) SHEETMETAL W/ INSULATION (GENERAL NOTES) BARE ROUND SHEETMETAL ROUND SHEETMETAL W/ INSULATION (GENERAL NOTES) BARE OVAL SHEETMETAL OVAL SHEETMETAL W/ INSULATION (GENERAL NOTES) EXAMPLE OF EXISTING EXAMPLE OF DEMO EXAMPLE OF NEW EXAMPLE OF FUTURE (N.I.C.) EXPOSED QUALITY SHEETMETAL CLEANROOM QUALITY DUCTWORK DUCTBOARD (1" FIBERGLASS) CONTINUATIION OF ROUND DUCT CONTINUATION OF RECTANGULAR DUCT AIR FLOW IN SYMBOL AIR FLOW OUT SYMBOL MECHANICAL EQUIPMENT TAG KEYED NOTE ACCESS DOORS RATED ENCLOSURE SYMBOL 14x12 SA 14x12 SA-SL 14x12 SA-W 120 SA 120 SA-W 14x120 SA 14x120 SA-W 14x12 SA 14x12 SA-Q 14x12 SA-C 14x12 SA-DB I AHU-001 E DESCRIPTION FLEX DUCT EQUIPMENT FLEX ROUND CONNECTOR EQUIPMENT FLEX RECTANGULAR CONNECTOR SUPPLY DUCT UP/DOWN EXHAUST DUCT UP/DOWN RETURN DUCT UP/DOWN SUPPLY AIR TERMINAL RECTANGULAR AND SQUARE RETURN AIR TERMINAL RECTANGULAR AND SQUARE EXHAUST AIR TERMINAL RECTANGULAR AND SQUARE RADIAL AIR TERMINAL SUPPLY AIR SLOT DIFFUSER RETURN AIR SLOT DIFFUSER EXHAUST AIR SLOT DIFFUSER POINT OF CONNECTION CENTER LINE THERMOSTAT CARBON MONOXIDE SENSOR NITROGEN DIOXIDE SENSOR OTHER SENSOR ELECTRICAL SWITCH MITERED ELBOW WITH TURNING VANES NOTE: SIZE REFLECTS ACTUAL SHEET METAL DIMENSION AND DOES NOT ACCOUNT FOR INSULATION OR LINING ABBV FULL NAME COMB-GALV COMBUSTION AIR SA SUPPLY AIR LP SA-KOOL SUPPLY AIR LP KOOLDUCT SA AL SUPPLY AIR LP ALUMINUM SA SS SUPPLY AIR LP SS 304 2B SA AL WELD SUPPLY AIR LP ALUMINUM WELDED SA GALV WELD SUPPLY AIR MP GALVWELDED SA GLVNL WELD SUPPLY AIR MP GALVANNEAL WELD SA SS WELD WELDED SUPPLY AIR LP SS 304 2B EA EXHAUST AIR ABBV FULL NAME EA AL EXHAUST ALUMINUM EA SS EXHAUST SS 304 EA AL WELD EXHAUST ALUMINUM WELDED EA GALV WELD EXHAUST GALV WELDED EA GLVNL WELD EXHAUST GALVANNEAL WELDED EA SS WELD EXHAUST SS 304 WELDED EA BI GREASE EXHAUST GREASE BLACK IRON WELD EA GALV GREASE EXHAUST GREASE GALV WELDED EA GALV GREASE EXHAUST GREASE S5 304 WELDED MUA MAKE-UP AIR SYMBO Jn 240 24x24 r r sipcY A) cED 0 . . ABBV FULL NAME 0A OUTSIDE AIR OA-KOOL OUTSIDE AIR KOOLDUCT RLF RELIEF AIR RA RETURN AIR DB DUCTBOARD FLU-CAT1 FLUE VENT- CATEGORY 1 FLU-CAT4 FLUE VENT- CATEGORY4 FLU-CPVC FLUE VENT - CPVC MATERIAL FLU -SS FLUE VENT- SHOP BUILT SS 304 FLU-GALV FLUE VENT - SHOP BUILT GALV SERVICE I USAGE OUTDOOR AIR INTAKE MEDIUM PRESSURE SUPPLY AIR LOW PRESSURE SUPPLY AIR FLEXIBLE DUCT RETURN AIR TRANSFER AIR RELIEF AIR GENERAL EXHAUST WASHROOM EXHAUST LOCATION BETWEEN AMBIENT AND AHU BETWEEN AHU AND TERMINAL UNITS FROM TERMINAL UNITS TO GRD'S CONN TO GRD'S FROM GRD'S TO AHU FROM GRD TOGRD FROM AHU TO AMBIENT FROM GRD TO FAN AND AMBIENT FROM GRD TO FAN AND AMBIENT NOTES: 1. SHEET METAL GAUGES AND FITTINGS PER SMACNA AND MACDONALD-MILLER DUCT CONSTRUCTION STANDARDS. 2. THERMAFLEX "GKM" OR EQUAL, WITH 12 FOOT MAXIMUM LENGTH. 3. INSTALL PER MFG. GUIDELINES AND INSTRUCTIONS. 4. UL 300 HOOD TO BE PROVIDED IN KITCHEN BY KITCHEN CONSULTANT. DUCTWORK SPRINKLERS NOT REQUIRED. 5. SLOPE AT 114" PER FOOT BACK TO HOOD. MATERIAL GALV. STEEL GALV STEEL__ GALV. STEEL PREINSUL. FLEX GALV STEEL GALV. STEEL GALV. STEEL GALV. STEEL GALV. STEEL WORKING PRESSURE (IN. WC) 0.5 2.5 SMACNA SMACNA PRESSURE SEAL CLASS (IN. WC) CLASS NOTES 1 8 .'..... 4 A RATED ♦6',-1"..._, . 2, 3 SHEET NUMBER TM0.01 TM0.02 TM0.01S TM2.02 TM2.03 TM2.05 SHEET NAME SCHEDULESHVAC SCHEDULESHVAC tSITE PLAN LEVEL2 MECHANICAL PLAN LEVEL 3 MECHANICAL PLAN ROOF MECHANICAL PLAN ISSUE TITLE M19-0207 ISSUE DATE REVISION REVISION DATE RECEEVER CITY OF 11RWILA DEC 18 2019 PERMIT CENTER 4 I I I I I I I I I I I I I I I I I I I I I I .921 80 I N PERMIT SET I I I I I I I< 0 Z w J 0 J Q CO r�m0 II'''1�LJ Q Z WGD W - �>" < CO CO 1- J /�� �NY VJ VJ ENGINEER: M CAVINESS CHECKED BY: K JOHANSON CAD: M HAGBERG DRAWING NUMBER: 0-1542-73192847-000 SHEET NUMBER: REVISIONS: H 03 REVISIONS: SSUED FOR PERMIT LAST REVISED: 12-18-19 DATE PLOTTED: 12-18-19 ISSUE DATE: TM0.02 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 03 2020 "{ City of Tukwila BUILDING DIVISION g\DWG\Shte\73 Wednesday, December 18, 2019 11:10:59 AM ClECEiVED C TY OF "i UKW;LA DEC 182019 PERMIT CENTER N.T.S. 4 I I I I I I I I I I I I I I I I I I I I I I 1071 w � a ao � PERMIT SET I I I I I 11< REVISIONS: REVISIONS: V Z 0 0 Z 'AUJ I..L J Om v J Q rr�nn I V Q Q W� Ur J1-� coo wW Q CO W I- J VJ VJ P ( ENGINEER: LAST REVISED: M CAVINESS 12-18-19 ISSUED FOR PERMIT CHECKED BY: DATE PLOTTED: K JOHANSON 12-18-19 CAD: ISSUE DATE: M HAGBERG DRAWING NUMBER: 0-1542-73192847-000 SHEET NUMBER: TMO.O1 S REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2020 City of Tukwila BUILDING DIVISION 6x6! E/LE \ 12x12 \ 340 Cs1 I 35 IL. - • UNDERCUT DOOR FOR TRANSFER L 160SA 0 /7 6x6 \ n/ 65 8x8 60SA 1 VAV-213 FIRE PLACE DURAVENT PRO 46DVA t- \E-v 400 1 -4-- * (TYP 3) , , T2RA0xN1s2 ,,---,:- INSTALL TIGHT TO WALL _ . . EXISTINo 54x24 LT\ 12x12 20x1 RA /E\12x6 80EA n//7 6x6 \ 95 , - 14x12SL RA rA14x12 920 10x10 TIMMTER,_ CE1 hVAV 8x8 n/205 8x8 x10 10x10 H 6: SCOPE OF WORK FSD 10x10 240. 0,0 ,• 7 12x8 n/ 330 (TYP 2) 75 100EA 60SA 120EA 12x1 SL ' - - - 2x6SL--RA 12x6 x16 T NS 14x12SL P‘A 14x12 TRANS i 18x16SL RA 1010 315 , — Y515 - 0 )EXISTIN 54x24 8x8 150 2x6RA 60 00 1 VAV,-201 70x24 FSD 70x24iR/A,.. x12 EXIL—Lj • - H5446SA )1/F, 12x6 I/TRANS m 80SA TR 12x12 TRANSFER ABOVE CEILING 12x10 .TRANS, I, Ox10 12x10 0 os 1-8x8 (A 4 ) - 12x6 __115 \ --I/ 180 g:R )" /7 8x8 Av1/190 (TYP 2) , • • !, , • • , • -;•••;,,-; RA 777 I '! 0 10x10 (TYP 5) M1 9-0207 1 RECEIVED CITY OF IV:AVILA DEC 1 8 2019 PERMIT CENTER Ez 1/8" = 1'-0" I I I I I I I I 1 1 1 1 1 1 1 1 PERMIT SET I I I I I I l< z 0 H ry L1. z CY < ry, Z I" 0 tn v a 0 —I CO a 0) ›- < W W ,(- 03 ENGINEER: M CAVINESS w 0 REVISIONS: ISSUED FOR PERM LAST LAST REVISED: 12-18-19 CHECKED BY: DATE PLOTTED: K JOHANSON 12-18-19 CAD: M HAGBERG ISSUE ATE: DRAWING NUMBER: C-1542-73192847-000 SHEET NUMBER: TM2.02 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 202G City of Tukwila I BUILDING DIVISION J:\7319\2847 Sobey IGW—B HQ Renovations\00\2 — Engineering\DWG\Shts\ SCOPE OF WORK 10x10 W 335 (TYP5) Wednesday, December 18, 2019 11:11:06 AM 1 VAV-312 1 M19-0207 RECEIVED CITY OF E U2:WILA DEC 18 2019 PERMIT CENTER 9z 1/8" = 1'-0" 4 �v) o� i" ( or 0 OD z0E(I) 0 X o LL j31 , 2"O • oO o < 6 C 0 7Q�Z O 0 o J N N >> t 0 2 �a I I I I I I I I W a I I I I I I I I 1 1 1 1 I I IF-'1 w (0 a O N PERMIT SET I I I I I 11< REVISIONS: REVISIONS: ISSUED FOR PERMIT ENGINEER: LAST REVISED: M CAVINESS 12-18-19 CHECKED BY: DATE PLOTTED: K JOHANSON 12-18-19 CAD: M HAGBERG ISSUE DATE: DRAWING NUMBER: 0-1542-73192847-000 SHEET NUMBER: TM2.03 REVIEWED FOR CODE COMPLIANCE • APPROVED JAN 03 2020 City of Tukwila BUILDING [31VISIC'NJ &\7319\2847 Sabey IGW—B HQ Renovations\00\2 — Engineering\DWG\Shth\7319284771,42_054wg Wednesday, December 18, 2019 1111:07 AM SCREEN WALL CO-208-T • ; VAt • IYALVE2•S /8" Rsbc - 1/2" RUC, \-\ NEW., ISOLATi VES k, CAP :2" LINE, 211 1 21 11 - • / ' ,- --34x: 4 I ,. RISE ;DUCT ,-: 4CWS/CW - I. Li / ...1 1 EC-11 / \ / LowR-iot/ Ovs--1 JOE? i C NDENSER SUPPLY FUTT.J 4'' 51 1 ICG-RTU1 . t , v. 6" FUTURE VALVES C_WR-121 • / 2CWISACVIIR CWSt21 SHEET NOTES REDUCE REFRIGERATION SUCTION LINE TO 7/8" OD IN VERTICAL RISER. LIQUID LINE TO REMAIN 1/2" OD. ROUTE RISERS DOWN TO 2ND FLOOR. [7a- u 0 rTu3 " c DEMOI E UNIT V PIPE 11.11=4-] UNIT ,0 BE LOCATED PER STRUC URAL DRAWINGS CIRCUIT SETTER CWS----181 STRAINER -ADO DPATINS //' — 4 1 CU- 5\1 FOILT-7-1 CU-81 SCOPE OF WORK CONNECT TO EXISTING, 54X26 / SA UP FROM 4TH FLOOR CU-9 I AC-2011 IEF-2011 r 71 \ /I I\ /li 1 1 )( 1 1 X \;_sl 1 \ I CONNECT7TO EXISTING R/A UP FROM 4TH FLOOR M1 9-0207 a IIECF.IVEn CITY OF TURWIA DEC 18 2019 PERMIT CENTER Ep 1/8" = 1'-0" Z. I I I I I I I I PERMIT SET I I I I I I l< z a - L.L.1 0 REVISIONS: REVISIONS: ENGINEER: LAST REVISED: M CAVINESS 12-18-19 CHECKED BY: DATE PLOTTED: K JOHANSON 12-18-19 CAD: ISSUE DATE M HAGBERG DRAWING NUMBER: C 1542-73192847-000 SHEET NUMBER: CODE COMPLIANCE APPROVED JAN 0 3 2020 City of Tukwila BUILDING DIVISION]