Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG19-0004 - COVALON - RELOCATE ELECTRIC WATER HEATER AND ADD WATER CLOSET
COVALON 12620 INTERURBAN AVE S #120 PG19-0004 Parcel No: Address: City of Tnnk"°"^U of _-p__'--'_° ----'--.-, Development6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 9G188 Phone;20G'43i-3670 Inspection Request Line: 206'438'9350 Web site: h#n://wvmm.TubwUaVVA.mnv PLUMBING/GAS PIPING PERMIT 8004880003 Permit Number: PG19-0004 Project Name [OVALON Issue Date: 1/18/2019 Permit Expires On: 7/17/2019 Owner: Name: Contact Person: Name: Address: Contractor: Name: License No: Name: nREGGCP|FDLYMPNPROP LLC POBOX 49UODEPT2U7C/O RYAN' 5COTTSDALE'VVA 85261 ]OSEPHPAPERN|K 1143J47TMAVE NE, MARYSV|LLE, WA, 98271 CITY PLUMBING INC 11432 47THAVE NE, MARYSVLLE WA, 98271 ''' Phone: 860454-0481 Expiration Date: 8/8/2020 DESCRIPTION OF WORK: RELOCATE 50 GALLON ELECTRIC WATER HEATER TO MAKE ROOM FOR ADA RESTROOM. ADD (1) WATER CLOSET, (1) URNIAL, (1) INDIRECT WASTE REIRCEPTOR AND (1) FLOOR DRAIN. CHANGE LAUNDRY TRAY TO WALL HUNG Valuation ofWork: $7,50000 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $238.34 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 015 20152015 2015 2015 National Electrical Code: VVACities Electrical Code: VVAC296-46B: WA State Energy Code: 2017 20172017 2015 Permit Center Authorized Signature: |hearbycertify that | have read and examined this permit and know the same tobetrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancelthe provisions pfany other state nrlocal laws regulating construction orthe performance ofwork. |amauthorized tnsign and obtain this development permit and agree tothe conditions attached tothis permit. SignaSignSignature:^ � t ure: ��� � Date: ~-IV — 1 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: No changes shall be made to applicable plans and specifications unless prior approval is obtainedfnomthe Tukwila Building Division. 2: Al I permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 3: All plumbing and gas piping systems shall beinstalled incompliance with the Uniform Plumbing Code and the Fuel Gas Code. u: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 5: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code, Tests shall beconducted inthe presence nf the Plumbing Inspector, kshall bethe duty of the holder nf the permit to make sure that the work will stand the test prescribed before giving notification that the work isready for inspection. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall beprotected hysteel nail plates not less than 18gauge. 7: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall bedirectly embedded inconcrete nrmasonry. 8: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls orpartitions shall beprotected inaccordance with the requirements nf the building code. 9: Piping inthe ground shall belaid onafirm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, x|ndepfiU.frozen earth, orconstruction debris. lO: The issuance ufapermit orapproval ofplans and specifications shall not beconstrued tubeapermit for, or anapproval of, any violation ofany nfthe provisions of the Plumbing Code orFuel Gas Code orany other ordinance ofthe jurisdiction. 11: The applicant agrees that he or she will hire licensed plumber to perform the work outlined in this permit. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 4DZofWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)43M-g3s0 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 nOVGH'|NPLUK8B|NG CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. pG19-000il Project No. Date Application Accepted: I Date Application Expires: -1 ""1 1 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 12620 Interurban Ave S Tenant Name: Covalon King Co Assessor's Tax No.: 0004800003 1 Suite Number: 120 &130 Floor: New Tenant: 1:1 Yes LI ..No PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Joseph Papernik Address: 11432 47th Ave NE City: Marysville State: Wa Zip: 98271 Phone: (360) 661-5568 Fax: (360) 454-0485 Email: jpapernik@cityplumbing.org PLUMBING CONTRACTOR INFORMATION Company Name: City Plumbing Inc Address: 11432 47th Ave NE City: Marysville State: Wa Zip: 98271 Phone: Fax: (360) 661-5568 (360) 454-0485 Contr Reg No,: CITYPI*955KJ Exp Date: 08/01/2020 Tukwila Business License No.: BUS-0993653 Valuation of Project (contractor's bid price): $ 7,500 Scope of Work (please provide detailed information): Relocate 50 gallon electric water heater to make room for ADA restroom. Add one toilet, urinal and floor drain to room. Change laundry tray to wall hung lavatory. Building Use (per Int'l Building Code). Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: PIAApplicationsWorms-Applications On Line \2011 Applications \Plumbing Permit Application Revisal 8-9-1 I.docx Revised; August 201 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rath water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (I -5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURYJ3X4HE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN AGENT: Signature: Print Name: Joe Papernik Mailing Address: 11432 47th Ave NE Date: 01/10/2019 Day Telephone: (360) 661-5568 Marysville Wa 98271 City State Zip IttApplicationsTorms-Applications On Une \2011 Applicadons \Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $238.34 PG19-0004 Address: 12620 INTERURBAN AVE S 120 Apn: 0004800003 $238.34 Credit Card Fee $6.94 Credit Card Fee R000.369.908.00.00 0.00 $6.94 PLUMBING $222.50 PERMIT FEE R000.322,100.00,00 0,00 $143.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322,103.00.00 0.00 $44.50 TECHNOLOGY FEE $8.90 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16453 R000.322.900.04.00 0.00 $8.90 $238.34 Date Paid: Friday, January 11, 2019 Paid By: KEVIN ROGGENKAMP Pay Method: CREDIT CARD 00631G Printed: Friday, January 11, 2019 7:54 AM 1 of 1 SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 01/11/2019 07:53:54 AM CREDIT CARD SALE VISA CARD NUMBER: **********1872 K TRAN AMOUNT: $238.34 APPROVAL CD: 00631G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy haps ://classic.convergepay .comNirtualMerchant/transaction.do?dispatchMethod—printTra... 1 /1 1 /2019 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 670 Permit Inspection Request Line (206) 438-9350 Project: e-0 V paL,A0K) Type,f nspe ion: 0,04., +17 "-c.„- Address: i 24,2--17 i dret40e--(34, Date Called: Instructions'Special 64..e., RIrOD Date Wanted: . , . Requester: Phone No: 24767 fo applicable codes. COMMENTS: ections required prior to approval. pector Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PG me, P ec : A T e spec on: Address: 20 Specialnstrucuons: Date anted: a.m. pdrs. Requester: Phone No: 4712.5- 31/.5- 2. pproved per applicable codes. D Corrections required prior to approval. MENTS: n pector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT ND. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 -Pest I &k2Y4 Project: 09Y Type of nspection: pi,N tokARL_ Address: Uale, Id..rertUe/344 At' Date Called: Special Instructions: 'Date Wanted: P- - Requester: AQ Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 147.00,4).D bt) Inspector:76' Date: Ze2/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. KOHLER® Features • Vitreous china. • Two-piece toilet. • Comfort Height® Elongated bowl. • Class Five® flushing system. • Includes left-hand polished chrome trip lever. • 1.6 gpf (6.0 Ipf). • 2-1/8" (54 mm) fully glazed trapway. • 12" 305 mm) rough -in. • Less seat and supply. • 1� 11 .- L_1 - •- 11-3/8" (289 mm) x 8" (203 mm) water area. • 29-3/4" (756 mm) x 18" (457 mm) x 31-1/4" (794 mm). • Floor mount / Floor outlet. Recommended Accessories K- 4636 Toilet Seat K- 4688 Toilet Seat K- 7637 Angle Supply with Stop (single) K- 4731-C Commercial Heavy-duty Toilet Seat Components Product includes: ,K- 4468 Toilet Tank 'K- 4199 Comfort Height® Elongated Bowl Additional included component/s: Tank cover, Trip lever, Bolt cap accessory pack, and Tank accessory pack. REVIEWED FOR CODE COMPLIANCE APPROVED JAN152019 City of Tukwila BUILDING DIVISION ADA Highline® Class Five® Toilet K-3979 LCSA B651] OBC I Codes/Standards ASME A112.19.2/CSA B45.1 DOE - Energy Policy Act 1992 ADA ICC/ANSI A117.1 CSA B651 OBC KOHLER® One -Year Limited Warranty See website for detailed warranty information. Available Color/Finishes Color tiles intended for reference only. Color J J • Code Description 0 White 96 Biscuit 47 Almond 7 Black Blackrm PG iq 000'i RECEIVED CITY OF TUKWILA JAN 11 2019 PERMIT CENTER USA/Canada: 1-800-4KOHLER (1-800-456-4537) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.kohler.com. 3-27-2016 05:56 THE BOLD LOOK OF KOHLER. Finished Wall 8-1/2" (21Gmm) f \ (10mm) 1G'1/2" (419mm) Technical Information All product dimensions are nominal. Toilet type: 8ow|ohmpe: Flush type: Trap passageway: Water Consumption Full: Water surface size: Rim towater surface: Rough -in: Seat -mounting holes: Two-piece Elongated front Class Five wye fitting. u'p mr/oupp "=~^.�,=_-^.� � (114mm) 1.600f(6|pD 11-3/8" x 8" (289 mmx203mm) 5'3/8"(137mm) 12^(3O5mm) ��~ ��U� �/�> unN��uuuU����"� Class F've@)Toilet F For Back -to -Back Toilet Installations Use a 45' double Do not use a double sanitary tee. Front of Bowl 1O4/8" (25 mm) Finished Floor Notes Install this product according hothe installation guide. For baok-bo-bmoktoilet installations: Use only 45^double wyefitting. AOA, OBC, C8A B651 compliant when installed bmthe specific requirements ofthese regulations. The Model Plumbing Codes require the installation ofelongated open -front toilet seats onpublic bathrooms. US/VCanodm:1-8UO4KOHLER(1 ) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go0mvm^wv.koh|er-opm. 3-27'201805:56 THE .. /� BOLD LOOK KOHLER® Features • Washout urinal. • 3/4" top spud. • 0.125 gpf (0.47 Ipf) to 1.0 gpf (3.8 Ipf). • 14" (356 mm) extended rim. • Will replace K-4904-ET. Material • Vitreous china. Water Conservation & Rebates • WaterSense-compliant when used with a 0.125 gpf or 0.5 gpf WaterSense flushometer. Recommended Accessories K-10668 WaterSense® 0.125 gpf Exposed Flushometer K-10949 TripointTM DC 1/8 GPF Urinal Flushometer K-13520 WaterSense® 0.125 gpf Exposed Flushometer K-7528 WAVE HES 1/8 GPF Urinal Flushometer K-7546 WaterSense® 0.125 gpf Exposed Flushometer K-10675 WaterSense® 0.5 gpf Exposed Flushometer K-10958 WaterSense® 0.5 gpf Exposed Flushometer K-7537 0.5 gpf Exposed Flushometer K-7526 WAVE HES 0.5 GPF Urinal Flushometer K-13519 0.5 gpf Exposed Flushometer K-10676 1.0 gpf Exposed Flushometer K-10960 1.0 gpf Exposed Flushometer K-13518 1.0 gpf Exposed Flushometer K-7539 TripointTM HES 1.0 GPF Blwout Flushometer K-7542 1.0 gpf Exposed Flushometer K-7527 1.0 gpf Exposed flushometer Components Additional included component/s: 3/4" inlet spud, 2" outlet spud, Strainer, and Hangers (2). BardonTM High -Efficiency Urinal K-4991-ET ADA Codes/Standards ASME A112.19.2/CSA B45.1 DOE - Energy Policy Act 1992 EPA WaterSense® ADA ICC/ANSI A117.1 KOHLER® One -Year Limited Warranty See website for detailed warranty information. Available Color/Finishes Color tiles intended for reference only. Color Code Description • 0 White 96 Biscuit 47 Almond 7 Black BlackTM USA/Canada: 1-800-4KOHLER (1-800-456-4537) www.kohler.com 4-18-2015 05:55 TI-E BOLD LOOK OF KOHLER. KOHLER® 2" NPT Tap 21" (533 mm) 3" (76 mm) / 3/4" Spud 19" (483 mm) 3" (76 mm) *24" 14-1/8" (610 mm) (359 mm) Technical Information All product dimensions are nominal. Flush outlet Washout technology: Spud size: 3/4", Inlet, Top Min. Water per Flush: 0.125 gal (0.5 L) Max. Water per Flush: 1 gal (3.8 L) Designed for the above water use when installed with a water -saving flushometer. Bardon TM High -Efficiency Urinal K-4991-ET 8" (457 mm) 12" (305 26-7/8" (683 mm 2" NPT Tap \ 1/4" (6 mm) Spud Detail Wall Hangers 40-1/2" (1029 mm) To Floor Notes Install this product according to the installation guide. Refer to manufacturer's instructions and local codes for flushometer requirements. ADA compliant when installed to the specific requirements of these regulations. 0 lir ts iq ic&°cc- 000, USA/Canada: 1-800-4KOHLER (1-800-456-4537) www,kohler.com 4-18-2015 05:55 THE BOLD LOOK OF KOHLER. SLOAN® Royal® Flushometer 186-1 ▪ Code Number 3012636 No- Description Exposed Urinal Flushometer, for 3A" top spud urinals. 111- Flush Cycle Model 186-1.0 Low Consumption (1,0 gpf/3.8 Lpf) 10. Specifications Quiet, Exposed, Diaphragm Type, Chrome Plated Urinal Flushometer with the following features: • PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass • ADA Compliant Metal Oscillating Non -Hold -Open Handle with Triple Seal Handle Pocking • I,P.S. Screwdriver Bok-Chek® Angle Stop • Spud Coupling and Flange for 'A" Top Spud • Sweat Solder Adapter with Cover Tube & Cast Wall Flange with Sel Screw • Non -Hold -Open Handle, Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation • Flush Accuracy Controlled by CID Technology • Diaphragm, Handle Packing and Vacuum Breaker to be molded from PERMEX® Rubber Compound for Chloramine Resistance 10. Accessories See Accessories Section of the Sloan catalog for details on these and other Flushometer variations, ▪ Fixtures Consult factory for matching Sloan brand fixture options. I---21/4"MIN. I (57mm) 1-02Imml CENTERLINE OF FIXTURE N. FIN. FLOOR WALL 0- Compliance & Certifications N'LP.S. SUPPLY (DN 20mm) Made In The USA This space for Architect/Engineer Approval SLOAN 10500 SEYMOUR AVE. • FRANKUN PARK, • IL. 60131 Ph: I-800-9-VALVE-9 or 1-847-671-4300 • Fox: 1-800-447-8329 or 1-847-671-4380 • http://www.sloan,com 2016-13-07 Page 1 of 1 Features w Vitreous china ° Wall -mount ° With hanger ° With overflow ° Drilled for concealed arm carrier ° Optional soap dispenser hole unleft (-L)orright (-F) °8^(203mm) centers, 4^(/i2mm)'centers orsingle hole m 2/'114" (54Dmm) x /8'118" (460mm) Codes/Standards Applicable Specified model meets orexceeds the following: °AD4 * /C/C/ANS/A//7/ ° CSAB65/ * (JBC ° ASMEA//2./0.2/CfAB45./ S���i���U���eU " —'-- Model WALL —MOUNT LAVATORY u������� ��^�N�N��� ADA �0: White °Other: Refer »oPrice Book for additional colors/finishes Accessories ° CP: Polished Chrome • Other: Refer to Price Book for additional colors/finishes Model Colors/Finishes X-2005 (1V2mm) centers less soap dispenser hole Qb Li Other K-2005-L Lavatory with 4^(102 mm) centers with soap dispenser hole on |oft O O O Other P-2005'R Lavatory with 4^(108 mm) centers with soap dispenser hole on right 00 O Other K'2006 Lavatory with 8^(288 mm) centers less soap dispenser hole Li uCnher K'2007 Lavatory with single hole less soap dispenser hole BO UOther K'2007'L Lavatory with single hole with soap dispenser hole on |e# DO []Other K'2007'R Lavatory with single hole with soap dispenser hole on right OO OOthor Recommended Accessories K,8998 P-Trap oCP oCxhor Product Specification Lavatory || be made ofvitreous china. The 18'1/8" ) in width. Lavatory shall be wall -mounted with hangers, Lavatory shall have 8" (203 mm) centers (K-2006), 4" (102 mm) centers (K-2005), or single hole (K-2007). Lavatory shall have overflow. Lavatory shall be drilled for concealed arm carrier. Lavatory shall have optional soap dispenser hole left (-L) or right (-R). Lavatory shall be Kohler Model K- Pago1of2 118611-4-CL USA/Canada: 1-800-4KOHLER (1'800'456'4537) KINGSTONTM Technical Information Fixture*: Basin area 16" (406 mm) x 10" (254 mm) Water depth 3-1/8" (79 mm) Drain hole 0 1-3/4" (44 mm) * Approximate measurements for comparison only. Holes K-2005 K-2006 K-2007 Spout 0 1-1/4" (32 mm) 0 1-3/8" (35 mm) 0 1-3/8" (35 mm) Faucet 0 1-1/4" (32 mm) 0 1-3/8" (35 mm) Soap dispenser 0 1-1/4" (32 mm) 0 1-1/4" (32 mm) Included components: Hanger 64839 Concealed Arm Hole Location 1/2" (13 mm) 4" (102 mm) 0 1-1/4" (32 mm Leveling Screw Hole 33 (84 K-2006 2" (51 mm) 4" (102 mm) Installation Notes Install this product according to the installation guide. Will comply with ADA when installed per Section 606 Lavatories of the Act. Will comply with CSA B651 when installed per Clause 4.3.3 of the standard. Will comply with OBC when installed per Clause 3.8.3.11. 3-3/4" (95 mm) Faucet Holes 17-1/4" (438 mm) 0 1-1/4" (32 mm) Locking Device 21-1/4" (540 mm) Hole 8-1/4" (210tmm) 12" "" (127 mm) (305 mm) 18-1/8" (460 mm) 34" (864 mm) Max 27" (686 mm) Min 9„ (229 mm) Min 9" --- (229 mm) .� tt (203 mm)\ ` (52 mm) ) Recommended ADA Installation mm) Hot 29-1/8" (740 mm) 4" 4-3/8" (111 mm) 7-1/4" (184 mm) 02 mm) 3/8" Cold 1-1/4" OD 12-7/8" (327 mm) 4-1/4" (108 m 31" (787 mm) Standard Installation Product Diagram KINGSTONTM WALL -MOUNT LAVATORY Page 2 of 2 116611-4-C L 4-1/4" (108 m K-2005 -L 4"(102mm -R 3-3/4" (95 mm) 4-1/2" (114 mm) K-2007 -L 4-3/8"(1111 mm)-R 3-3/4" L(95 mm) THE BOLD LOOK OF KOHLER. MOEN® COMMERCIAL DESCRIPTION • Solid brass construction • Chrome, Brushed Chrome or Brushed Nickel finish • 1/2" IPS connections • Solid brass waterways OPERATION • Lever handle • Temperature controlled through 110° arc of handle FLOW • Aerator is limited to 2.2 gpm max (8.3 L/min) CARTRIDGE • Ceramic disc cartridge *(with temperature limit stop) • Nonmetallic/nonferrous and ceramic material STANDARDS • Third party certified to CSA B125.1, ASME A112.18.1, ANSI A117.1, and all applicable requirements referenced therein • Certified to ANSI/NSF 61/9 • Contains no more than 0.25% weighted average lead content • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act ADA for lever handles WARRANTY • Warranted for 5 years against material or manufacturing defects 6" (153mm) 5- /8" (14 m 2- /2" (64mm) Specifications Single Handle Lavatory Faucet Less Drain Model: 8413* With Metal Pop-up Drain Assembly Models: 8414*, 8414BC, 8414BN NOTE: THIS FAUCET IS DESIGNED TO BE INSTALLED THRU 3 HOLES, 1" MIN. DIA. 7" (128mm) 1-1/8MAX. (29mm) CRITICAL DIMENSIONS (DO NOT SCALE) 2-7/16" (62mm) 6-5 8" (168mm) Rev. 3/11 MOEN SPECIFIER SERVICES 1-800-321-8809 Ext. 2158 www.moen.com j'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0004 DATE: 01/11/19 PROJECT NAME: COVALON SITE ADDRESS: 12620 INTERURBAN AVE S - SUITE 120 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: P'WO V1 Building Division 111 Public Wo ks Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) Planning Division Permit Coordinator III DATE: 01/15/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 02/12/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/1B/2013 Non -Residential Sewer Uise Certification Sewage Treatment Capa ty Charge or King County Department of Natural Resources and Parks Wastewater Treatment Division To be completed for all new sewer connections, reconnections or change of use of existing connections. Please Print or Type /2 C 2 o /n1 l ►Liz /A 2 f3 iglu A t/,y S Property Street Address City State ZIP Owner's Name sl^c�i rs Owner's Mailing Address ,72, L3c.X City 30Ai= State ZIP Owner's Phone Number including Area Code Property Contact Phone Number including Area Code Party to be Billed (if different from owner) Address City State ZIP A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clothes washer or laundry tub 4 2 Sink, bar or lavatory 2 1 / Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 f Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 / Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total Fixture Units _ 20 - ms, RCE For King County Use Only Account # No. of RCEs Monthly Rate !operty Tax ID # Subdivision Name Subdiv. # Block # Building Name (if applicable) City or Sewer District Date of Connection Side Sewer Permit # Lot # Please report any demolitions of pre-existing structures on this property. Credit for a demolition may be given under some circumstances. (See King County Code 28.84.050, 0.5) Demolition of pre-existing structure? ❑ Yes ❑ No Was structure on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date Type of structure demolished Request to apply demolition credit to multiple structures? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Un Type of Facility/Process: identified in Section A) RECEIVED CITY Estimated Wastewater Discharge:OF TUKWII.A Gallons/daysjAN 11 2019 Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0pERMIT CENTER Total Discharge (gal/day) _ RCE 187 C. Total Residential Customer Equivalents: (add A 8. B) A +B Total RCE Pursuant to King County Code 28.84.050, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the Metropolitan King County Council at a rate per month, per residential customer or residential customer equivalent, for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-477-5516. understand that the information given is correct. I understand that the capacity charge levied will be based on this information. I understand that any deviation may result in a revised capacity charge. 1' s Signature of Owner/Representative f *-^---- Print Name of Owner/Representative /<r .- i,// rN 1610_6969w_nonres_sewer_cap_chg_1058.indd White - King County Yellow - Local Sewer Agency Pink - Date 1 'urn(' Fffuniol Contact [Search L&I Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-Z Index Help My Ltd Workplace Rights Trades & Licensing CITY PLUMBING INC Owner or tradesperson Principals PAPERNIK III, JOSEPH S, PRESIDENT KNOWLES, SHELLY RAE, AGENT BERKMAN, RICHARD L, VICE PRESIDENT (End; 07/21/2010) Doing business as CITY PLUMBING INC WA UBI No 602 218 839 11432 47th ave ne MARYSVILLE, WA 98271 360-454-0481 SNOHOMISH County Business type Corporation Governing persons RICHARD L BERKMAN JOE S III PAPERNIK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. CITYPI*955KJ Effective — expiration 05/11/2005— 08/08/2020 Bond Lexon Ins Co Bond account no 9808230 Received by L&I 07/07/2011 Insurance Contractors Bonding & Insuranc Policy no, A31ADJ269 Received by L&I 07/30/2018 $6,000 00 Effective date 08/01/2011 Expiration date Until Canceled $1,000,000.00 Effective date 08/01/2018 Expiration date 08/01/2019 Insurance history Help us improve S s T ID LA\ N.T.S. TRUE NORTH NORTH VC\ITY MAP N.T.S. PROJECT AND BUILDING DATA BUILDING CODE: 2015 IBC WITH WASHINGTON STATE AMENDMENTS LOCATION: TUKWILA COMMERCE PARK, BUILDING A 12624 INTERURBAN AVE S TUKWILA, WA PARCEL NUMBER: 0004800003 ACCOUNT NUMBER : 000480000306 CONSTRUCTION TYPE: OCCUPANCY GROUP(S): ZONE: LOT AREA: V-B eSPRINKLERED GROUP B OFFICE AND S1 WAREHOUSE C / L-1 465,295 SQ FT (10.68 ACRES) TENANT SUITE: 5,500 S.F. PARKING: NO CHANGE SCOPE: COMBINE 3 SPACES INTO ONE TENANT SPACE, DEMOLITION NON BEARING WALLS, NEW WALLS, NEW OFFICES WITH IN EXISTING OFFICE BUILD OUT, NEW RESTROOM. ENVELOPE: NEW INSULATION AND MAKE HEATED WAREHOUSE, CHANGE EXTERIOR WINDOWS TO MEET ENERGY CODE FILE Permit No. Plan review approval is ublect to errors ana omissions Approval of construction documents does not auth arize the violation of any adopted code or ordinance Receipt of approved Field Copy and conditions ycknowiedged: By Date: / — I � --1 City of Tukwila BUILDING DIVISION REVISIONS No changes shall be to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan rev LEGAL DESCRIPTION LEWIS C C—D C # 37 BEG N 81-44-15 E 199.17 FT FROM HUB AT END OF CURVE ON CENT LN OF DUWAMISH—RENTON JUNCTION RD SD HUB BEING APPROX 1200 FT N AND 440 FT W OF 1/4 COR BET SECS 14 & 15-23-4 TH N 49-24-00 W 2535 FT TH N 09-36-00 E 52 FT TO TRUE BEG TH S 82-40-30 E 590 FT TH N 59-22-30 E 643.35 FT TH N 01-51-30 W 343 FT TO LEFT BANK OF DUWAMISH RIVER BEING NLY BOUNDRY OF LEWIS D C TH SWLY ALG SD BANK OF RIVER TO PT N 00-39-40 W OF TRUE BEG TH S 00— 39— 40 E TO TRUE BEG ALSO POR OF D C LY W OF ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT STRIP ADJ AND PARL TO ELY LN OF R/W OF P S ELEC CO FOR JOINT RD TGW LOT 47 OF PLAT OF RIVERSIDE INTERURBAN TRS BUILDING AREA AND UNSEPERATED USES: BUILDING IS SURROUNDED BY 60 YARDS, PER SECTION 507, 507.3 BUILDING AREA IS UNLIMITED IN GROUP B,F,M OR S OCCUPANCIES WHEN SPRINKLED. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical H/ Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 15 2019 • MA City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 11 2019 PERMIT CENTER 1?&l'1 000i1 N N 0 0 W Q_ w J W 03 I N O 0 -57 0 m 0 I.J.l 0 w 0 H 0 SUBMIT FOR PERMIT w Q 0 11-28-18 (0(.0 00 N w z 0x �LL grajd. > C—(1) L,juo 0 LE 0 . z U� 0 (24 H W O co O O� W c E-1�--IN T-1 OFFICE OFFICE --- REMOVE EXISTING OVERHEAD CANOPY AS REQUIRED FOR REMOVAL AND REINSTALL OF STROEFRONT REMOVE EXISTING UN INSULATED STOREFRONT FOR NEW STOREFRONT REMOVE EXISTING UN INSULATED WINDOWS FOR NEW WINDOWS OPEN OFFICE NO CHANGES TO EXISTING OFFICES J WAREHOUSE A OFFICE 41'-7" OFFICE X. H TEL OPEN OFFICE REMOVE EXISTING WALLS AND -DOORS EX. H 4:2X. HC RR ❑ nRR REMOVE EXISTING WINDOW AND FRAME, REUSE 1 OFFICE - OFFICE LEVEL EXISTING 7- CONCRETE SLAB IN CORNER REMOVE EXISTING WALL FOR NEW WINDOW, REUSE FRAME WAREHOUSE REMOVE EXISTING FULL HEIGHT DEMISING WALL A 37'-9" 1 OFFICE 17 OFFICE OFFICE 0 Pi V OPEN OFFIC 11 EX. HC RR � o EX. HC RR El n REMOVE EXISTING 1O'X10' NEW DOOR ELECT. EX. HC RR 0 EX HC RR 24 OFFICE UNCH OYFICE 23 REMOVE EX. DOOR AND WALL FOR NEW DOOR WAREHOUSE ALL FOR 20'-2" REMOVE EXISTING OVERHEAD DOOR FOR NEW STOREFRONT REMOVE EXISTING HOLLOW METAL DOOR FOR NEW HOLLOW METAL DOOR u 31'-2" REMOVE EXISTING WALLS FOR NEW WORK REMOVE EXISTING WALLS ENLARGE LUNCH EDFLOOR PLAN: DEMO TUKWILA COMMERCE PARK BLDG. B NORTH REMOVE EXISTING ELECTRICAL PANEL,RELOCATE \/ DRIVE IN DOOR DOCK HIGH DOOR DEMO NOTES; 1. REMOVE EXISTING WALLS AS SHOWN, PATCH AND REPAIR WALLS, FLOOR, AND CEILING AS REQUIRED 2. REMOVE EXSTING UN USED LOW VOLTAGE WIRING OF CABLE, PHONE, ETC. 3. REMOVE EXISTING ELECTRICAL IN WALLS BEING REMOVED. PULL OVERHEAD TO A JUNCTION BOX NOTED WITH PANEL AND CIRCUIT. 4. REMOVE EXISTING FLOORING AND BASE AS REQUIRED. EXISTING DOOR SCHEDULE: 1 & 12 EX. ALUMINUM STOREFRONT DOOR, UN INSULATED REMOVE 2,3,5,11 EX. 3'X7' SC WOOD DOORS, WOOD JAMBS, 13,16-19,23 LOCKSETS 4.7.10 14, 24 6, 8, 9, 20 21 22 25,26 27,29 28 30,32,33 31,34 EX. 3'X7' SC WOOD DOORS, WOOD JAMBS LOCKSETS, THRESHOLDS, WEATHERSTRIP, CLOSER EX. 3'X7' SC WOOD DOORS, WOOD KA,MBS, PRIVACY LOCK EX. 3'X7' SC WOOD DOOR, WOOD JAMBS, PUSH/PULL, CLOSER EX. 3'X7' SC WOOD DOOR, WOOD JAMBS, LATCHSET EX. 3'X7' SC WOOD DOORS, WOOD JAMBS, PRIVACY LOCK, WEATHERSTRIP THRESHOLD, CLOSER EX 10'X10' UN INSULATED OVERHEAD DOOR TO BE REMOVED EX. 3'X7' H. METAL DOOR AND JAMB, REMOVE DOOR EX. 10'X10' OVERHEAD DOORS EX. 3'X7' H. METAL DOOR AND JAMB, UNINSULATED TO BE REMOVED 2EVIEWED FOR. CODE COMPLIANCE APPROVED JAN 15 2019 City of Tukwila BUILDING DIVISION 'RECEIVED CITY OF TUKWILA JAN 11 2019 PERMIT CENTER rijoZ Z 944' 0Z04: :44TP4 1241 Ito 0 N 0 citig rn Sit T is , _ IIt_.A..I 3t It I\TERIM ELEVATIO\ SCALE:1 /2" = 1 11 RESTROOM NOTES: 1. ALL ACCESSORIES TO BE MOUNTED AT +40" TO OPERATING PORTION 2. INSULATE THE HOT, WASTE AND COLD WATER UNDER SINKS 3. TOILET FLUSH VALVE ON THE WIDE SIDE OF ROOM 4. SHEET VINYL FLOORING WITH SEAM SEALER AND COVED 6" SHEET VINYL BASE. REMOVE EX. WINDOW INSTALL NEW INSULATED STOREFRONT WINDOW EXTERIO; WI\DOW SCALE:1 /2" = ti WOOD SLOPE SOFFIT ABOVE 2 BULB LIGHT BAR FULL WIDHT MIRROR TO BACKSPLASH 0 rn ti 8" \SGE PAINT 1 GRAB BAR `PLASTIC LAMINATE WAINSCOAT 24" 18" FLUSH HANDLE ON OPEN SIDE N) COVED SHEET VINYL BASE INSULATED HOT & COLD WASTE PIPE INTERIOR ELEVATIO\ SCALE: 1/2" = 1'-0" INSTALL NEW TOILET AND URINAL TO MEET ADA STANDARDS AWNING NOT SHOWN FOR CLARITY SG SG SG SG SG L12'-3" REMOVE EX. STOREFRONT INSTALL NEW INSULATED STOREFRONT W/ DOOR \OATH EXTERIOR STMEFRO\T REMOVE EX. STOREFRONT INSTALL NEW INSULATED STOREFRONT W/ DOOR / SG SG SG SG SG SG I, 12'-3r EXTERIOR STOHRO\T scnLEa/s° = i -o \03TH ORTH REMOVE EX. OVERHEAD DOOR INSTALL NEW INSULATED STOREFRONT SG SG 10'-D" EXTRI k 0� STORERO\T SOUTH READ SCALE:1 /2" = 1'-0" WINDOW ENERGY: NEW STOREFRONT SYSTEM TO BE DOUBLE INSULATED GLAZING, LOWE E TYPE C, ARGON FILLED, ANY SPACER, THERMAL BROKEN FRAME, BRONZE TO MATCH EXISTING DARK BRONZE, U-0.37 (C303.1.3(5) DEFAULT VALUE IS 0.65 (C303.1.3(1) EXISTING SINGLE PANE,GLASS, WITHOUT THERMAL BROKEN. FRAME U=1.58 WALL SCHEDULE: 1 NEW 3 5/8" X 25 GA STEEL STUDS AT 24" 0.C. TO CEILING (BRACE TO ROOF STRUCTURE AT MAX 8' 0.C., WITH FULL THICK SOUND BATTS, 5/8" GYP BD EACH SIDE 2 NEW IN FILL, STEEL STUD TO MATCH WALL THICKNESS, 5/8" GYP BD EACH SIDE 3. NEW FURRING OVER EXISTING WALLS, R-10 RIGID INSULATION ONTO EXSTING WALL,TO 8' AFF, 3 5/8" STEEL STUD X 20 GA, TO 8'AFF WITH R-13 BATT INSULATION, VAPOR BARRIER, 5/8" GYP BD TO 8' AFF (U-0.45) FROM 8' TO ROOF DECK, INSTALL R-19 STICK PIN INSULATION W/ WHITE VINYL FACING FS 25 (U=0.44) 4 NEW FURRING OVER EXISTING EXTERIOR TILT UP CONCRETE, R-10 RIGID INSULATION ON CONCRETE TO 8' AFF, 3 5/8" STL STUD X 20 GA AT 24" O.C. TO 8' AFF, WITH R-13 BATT INSULATION , VAPOR BARRIER, 5/8" GYP BD TO 8' AFF (U=0.05) U-0 FROM 8' AFF TO ROOF DECK, INSTALL R-19 6" STICK PIN INSULATION WITH WHITE VINYL FACING FS 25 ( -.49 ) EX. OFFICE COMBINED = 2,144 SF © 1/100 = 21 OCCUPANTS SINGLE EXIT REQUIRED. EX. OFFICE 2980 SF © 1/100 30 OCCUPANTS SINGLE EXIT REQUIRED. 55'-3" 0 0 rn CN OFFICE OFFICE OPEN OFFICE OFFICE OFFICE O EX.HC TEL WAREHOUSE WAREHOUSE COMBINED = 4,975 SF © 1/500 = 10 OCC SINGLE EXIT REQUIRED REPLACE ALL WAREHOUSE LIGHTING WITH NEW LED LIGHTS (SEPARATE PERMIT) MAX 0.5 WATTS PER SF RELOCATED ELECTRICAL PANEL J r , i A 41'-7" A OPEN OFFICE i �EX.H� EX.HC RR Op RR NEW OFFICE g°,7 WAREHOUSE NEW HALL NEW OFFICE NEW OFFICE 11'-4" A 37'-9" OFFICE j-cr_f 1 NEW $ OFFICE OFFICE 8'-2" OPEN OFFICE EX.HC RR n 0 R 5' DIA TURNING—' 5'X5' CLEAR SPACE AT TOILET- / ELECT. i 10'-0 20'-2" 2 10'-6" 0 EX HC 0RR 4, OFFICE 0 NEW OFFICE o N9 0\ NEW LUNCH J LUNCH OFFICE -RELOCATE HOT WATER TANK AND OVERFLOW DRAIN WAREHOUSE WAREHOUSE 2,511 SF © 1/500 = 5 OCC SINGLE EXIT REQUIRED REPLACE ALL WAREHOUSE LIGHTING WITH NEW LED LIGHTS (SEPARATE PERMIT) MAX 0.5 WATTS/SF 17C61)- FIVAC (5 ION) TICEWAREFTOUSE UNDER SEPARATE PERMIT 10'-0" 31'- 1 J 0 0 ALL NEW FINISHES IN THESE SPACES, PAINT DOORS AND JAMBS FLOOR PLAN: NEW TUKWILA COMMERCE PARK BLDG. B 12620+1262X INTERURBAN AVE. S. NORTH TUKWILA, WASHINGTON V DRIVE IN DOOR DOCK HIGH DOOR WINDOW SCHEDULE: W1 INTERIOR RELITE, 2'-0" X 6'-6" ON 6" CURB (MATCH EXSTING, 1 /4" CLEAR GLAZING IN WOOD FRAMES, SAFETY GLAZING AS REQUIRED BY CODE W2 NEW STOREFRONT SYSTEM ,BRONZE ANODIZED THERMAL BROKEN FRAMES, 1" INSULATED GLAZING WITH LOW-E,(SAFETY GLAZING AS REQUIRED), (U=0.37) W3 NEW 65" X 36" (VERIFY IN FIELD), DARK BRONZE,THERMAL BROKEN FRAMES WITH 1" CLEAR GLAZING WITH LOW-E, (U=0.37) W4 NEW 10' X10' STOREFRONT SYSTEM, DARK BRONZE THERMAL BROKEN FRAMES WITH 1" INSULATED GLAZING WITH LOW-E, (SAFETY GLAZING PER CODE) PROVIDE PRIVACY FILM ON BOTTOM GLASS PANELS, (U=0.37) W5 NEW 1" SAFETY GLAZING AND INSULATED, IN RE USED EXISTING FRAME (U=0.40). DOOR SCHEDULE ALL NEW DOORS TO HAVE LEVER MAX 1/2" THRESHOLDS REVIEWED FOR CODE COMPLIANCE APPROVED JAN 15 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 11 2019 PERMIT CENTER HANDLES,REUSE AS APPROPRIATE, N1,N2 NEW 3'-0" X 7'-0" BRONZE ALUMINUM STOREFRONT DOOR, INSULATED, SAFETY GLAZING, CYLINDER WITH EXIT PADDLE, WIRE PUSH AND PULLS, DARK BRONZE TO MATCH EXISTING, WITH CLOSER, THRESHOLD LATCHGUARD,WEATHERSTRIP (U=0.06) N3,N4,N5 NEW 3'-0" X 7'-0 SC WOOD, WOOD JAMBS,1 1/2 PAIR N6,N7 BUTTS,LOCKSET,WALL STOP N8 NEW 3'-0" X 7'-0" SC WOOD, WOOD JAMBS, 1 1/2 PAIR BUTTS, PRIVACY, LOCK, CLOSER, THRESHOLD,WEATHERSTRIP (U=0.34) N9 NEW 3'-0" X 7'-O" SC WOOD DOOR, WOOD JAMB, 1 1/2 PAIR BUTTS, PUSH/PULL, CLOSER N10 NEW 3'-0" X 7'-0 H. METAL,INSULATED DOOR (EX. JAMBS), LOCSET,CLOSER, THRESHOLD, WEATHERSTRIP, DRIP CAP, LATCH GUARD,(U=0.34) N11 NEW PAIR 5'-0" X 10'-0" H. METAL DOOR INSULATED, H. METAL JAMBS, SPRING BOMMER HINGES, PUS AND PULL, WINDOW (INSULATED), WEATHERSTRIP, WALL STOP Ott As 1 II it iP.l z Sz Po I() 54C; gSz ®a O oar I1�11 LOP Tzi 44 ICI Z 94440 I ia1 :44z g anti Z 151.11 00 P4 CO C 0 c I0'_ A_. \ I /. lirri gx eD if 5/, 1-iehAc'r it �? Gt> � k` 46-- � ,r G �.11tlYt Lie is - ,o y if, I/2 eroileA- w . Caw f)„ nfl (v vay‘,r 41"4- REVIEWED FOR CODE COMPLIANCE APPROVED JAN 152019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 11 2019 PERMIT CENTER PLUMBING IN 11432 47th Ave NE Marysville, Wa 98271 Phone 360-454-0481 Fax 360-454-0485 jpapernik@cityplumbing,org 7 U d O d (1)oC° U �0 E E 0 a, (/) Y_y I— I — DATE: 1/10/2019 Pl.urrloing Drawing{