Loading...
HomeMy WebLinkAboutPermit PG19-0010 - WHITMORE LAW - ADD BREAK ROOM SINK, DISHWASHER, FUNNEL DRAIN AND WATER HEATERWHITMORE LAW 6840 FORT DENT WAY UNIT 210 PGI 9-0010 Parcel No: Address: City mfTukwila Department of Community Development 6300 SouthcenterBoulevard, Suite 01O0 Tukwila, Washington 90180 Phone: 206'431'3670 inspection Request Line: 206-438'9350 Web site: htto://wvmm.Tukm/UawVA.mmv PLUMBING/GAS PIPING PERMIT 2954900425 Permit Number: PG19-0010 6840 FORT DENT WAY Unit210 Project Name: WHITMORE LAW Issue Date: 2/13/2019 Permit Expires On: 8/12/2019 Owner: Name: Contact Person: Contractor: Name: Address: License No: Name: Address: 8OHNCRADOV[HDEVCID Z83SQZNDAVSE#S-1,MERCER ISLAND, WA, 98040 8]EPAPERN|K 1143247TMAVE NE, KxARYSV|LLE, WA, 98271 CITY PLUMBING INC 11432 47T*AVE NE, Kx4RYSV\LLE, VVA98Z71 OTYp|~9s50 ''' Expiration Date: 8/8/2020 DESCRIPTION OF WORK: ADD BREAK ROOM SINK, DISHWASHER, FUNNEL DRAIN AND WATER HEATER Valuation of Work: $9,500.00 Water District: TVKWILA Sewer District: TUKWILA Fees Collected: $198.17 Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: mACities Electrical Code: VVACZ96-468: WA State Energy Code: f Date:� �] -� / _/ ��/ ^ . I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate mcancel the provisions ofany other state arlocal laws regulatingconstruction prthe performance nfwork. |amauthorized tosign and obtain this development p99ni[pndagree tothe c9pdidorvr4tachedtothis permit. Signature: Print Name: Date: This permit shall become null and void ifthe work bnot commenced within 18Odays for the date ofissuance, orif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ~^~PLVKxB|NG/GA5PIPING PERMIT COmonnOmS~~~ 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall bpinstalled incompliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall hetested and approved asrequired bythe Plumbing Code and Fuel Gas Code. Tests shall beconducted inthe presence ofthe Plumbing Inspector. it shall bethe duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work |sready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall beinsulated tominimum R'3. O: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall beprotected bysteel nail plates not less than 18gauge, 9: Piping through concrete ormasonry walls shall not besubject tnany load from building construction. No plumbing piping shall bedirectly embedded inconcrete u,masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected inaccordance with the requirements ofthe building code. 11: Piping inthe ground shall belaid onafirm bed for its entire length. Trenches shall beback0|edinthin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, dnderOU'frozen earth, orconstruction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance ufthe jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14; All new plumbing fixtures installed innew construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 4VZofWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2V6)438'93sV 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING Tenant Name: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. - 6 j - /Q Project No. Date Application Accepted: Date Application Expires: "1".- e" 17 (For office use only) -10-19 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2954900425 Site Address: 6840 Fort Dent Way Whitmore Law Suite Number: 21.0 Floor: 2nd PROPERTY OWNER Name: John C Radovich Development Address: 2835 82nd Ave SE City: Mercer Island State: Wa Zip: 98040 CONTACT PERSON — person receiving all project communication Name: Joe Papernik Address: 11432 47th Ave NE City: Marysville State: Wa Zip: 98271 Phone: (360) 661-5568 Fax: (360) 454-0485 Email: jpapernik@cityplumbing.org New Tenant: ] Yes ❑ ..No PLUMBING CONTRACTOR INFORMATION Company Name: City Plumbing Inc. Address: 11432 47th Ave NE City: Marysville State: Wa Zip: 98271 Phone: (360) 661-5568 Fax: (360) 454-0485 Contr Reg No.: CITYPI*955KJ Exp Date: 08/08/2020 Tukwila Business License No.: BUS-0993653 Valuation of Project (contractor's bid price): $ 9,500 Scope of Work (please provide detailed information): Add break room sink, dishwasher, and water heater / rµ Building Use (per Int'I Building Code). Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mutt) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY. LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: T: Date: 01 / 17/2019 Print Name: Joe Papernik Day Telephone: (360) 661-5568 Mailing Address: 11432 47th Ave NE Marysville Wa 98271 City State Zip H;\Applications\Fonns-Applications On Line\201 I Applications\1'lumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt Receipt Number R16531 City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $198.17 PG19-0010 Address: 6840 FORT DENT WAY Unit210 Apn: 2954900425 $198.17 Credit Card Fee $5.77 Credit Card Fee R000.369.908.00.00 0.00 $5.77 PLUMBING $185.00 PERMIT FEE R000.322.100.00.00 0.00 $113.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $37.00 TECHNOLOGY FEE $7.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16531 R000.322.900,04.00 0.00 $7.40 $198.17 Date Paid: Friday, January 18, 2019 Paid By: KEVIN ROGGENKAMP Pay Method: CREDIT CARD 00362G Printed: Friday, January 18, 2019 81.0 AM 1 of 1 SYSTEMS CO TVKWILu ETRxKIT 6280 SUUTMC[NTEK 8LVD TUKWILA' W4 98188 206'4]}'1870 CITY OF TUKWILu 0017340000802374464500 Date: 8I/I8/2819 08:10:12 AM CREDIT CARD SALE VISA CARD NUMBER: ***^******I872 K TRxw AMOUNT: $I98.17 APPROVAL [D: 00362G RECORD #: 080 cLsxx ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO pxv THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD I95Usn AGREEMENT (MERCHANT AGREEMENT IF CREDIT v0V[HEK) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PC91(1-00/0 Type o nsp on: Addr s: ate ailed: ,Special Ins ucti s: Date Wanted: a.m. . . Requester: Phone N : 7 Approve applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: AI ri-rie I Type of n ec n: Add e : D te Called: Special Instructions: iDate Wanted: 2 . . Requester: Phone No: 24:& Approved per applicable codes. Corrections required prior to approval. ONIIVIENTS: 7-1 clA41, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 ® 0 FAU CET © C3 0 U P" 01 A Moen Incorporated Brand DESCRIPTION • Metal construction with various finishes identified by • Includes hose and spray • Hose reach 36, hose length 48" • 1/2" IPS connections • Six (6) individual boxes per master carton • Side spray finishes matches faucet finishes OPERATION • Lever -style handles • Hot side: Turn counterclockwise to open (clockwise t • Cold side: Turn clockwise to open (counterclockwise • Will operate with less than 5 lbs. of torque • No grasping motion required to operate the faucet handles FLOW • Aerator limited to 1.5 gpm (5.7 L/min) CARTRIDGE • Ceramic disc technology • Non-metallic, non-ferrous, and brass material • Single body construction for easy replacement STANDARDS • Third party certified to IAPMO Green ASME Al 12.18.1/CSA B-125.1 and all applicable requirements referenced therein including NSF 61/9 • Meets CalGreen and Georgia SB370 requirements • Contains no more than 0.25% weighted average lead content • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act • ADA for lever handles • Features red/blue hot/cold temperature indicators WARRANTY — RESIDENTIAL, COMMERCIAL • Ten year limited warranty against defects in materials and manufacturing workmanship • Refer to the installation instructions enclosed with each CFG product or call 1-888-450-4910 for complete warranty information uffix REVIEV CODE COMPLIANCE APPROVED FEB 0 7 2C19 City of Tukwila clabilLDING DIVISION 0 N apstone° Two Handle High -Arc Kitchen Faucet Model: CA41613 series with side spray Model: CA41611 series less side spray 01,ANSF e UPC CRITICAL DIMENSIONS • This faucet designed to be installed through 4 holes, 1-1/4" minimum diameter, 8" centers • Maximum deck thickness 1-1/8" (28.6mm) 10.941" (277.9 mm) 4.000" (101.60mm) (101.60 mm( 10.250' (26035 mm( 13 500' (342.9 mm) , I` 6.963' (176.86 mm( 4.000" RECt:4��� CITY OF 1 UKWILA JAN182019 Pl RMIT CENTER MAX. 1.125 (29 mm) 9.030" (229.36mm) (52 mm) &ioo 10 CRITICAL DIMENSIONS (DO NOT SCALE) CLEVELAND FAUCET GROUP • 25300 AL MOEN DRIVE • NORTH OLMSTED, OHIO 44070 • (888) 450-5522 • WWW.CFGONLINE.COM Rev. 5/13 DAYTO N* SPECIFICATIONS PRODUCT SPECIFICATIONS Dayton® Stainless Steel Single Bowl Top Mount Sink. Overall dimensions are 25" x 21-1/4" x 5-3/8". Sink is manufactured from 22 gauge 300 series Stainless Steel with a Satin finish, Rear Center drain placement and Bottom only spray. Installation Type: Top Mount Material: 300 series Stainless Steel Finish: Satin Gauge: 22 Sound Deadening: Bottom only spray Number of Bowls: Sink Dimensions: 25" x 21-1/4" x 5-3/8" Bowl 1 Dimensions: 21" x 15-3/4" x 5-1/4" Drain Size: 3-1/2" (89mm) Drain Location: Rear Center Minimum Cabinet Size: 30" Mounting Hardware: Part # 64090012 included for countertops up to 3/4" (19mm) thick Cutout Template #: 1000001245 emp a e is avaiiaoie Tor ciownioaa at e1k8yc0m Cutout Dimensions for Top Mount Installation: 24-3/8" x 20-5/8" (619mm x 524mm) with 1-1/2" (38mm) corner radius niThis sink is compliant to ADA and ANSI/ICC A117.1 accessibility requirements when installed according to the requirements outlined in these standards. Hole Drilling Configurations: 1-1/2" (38mm) Diameter Faucet Holes on 4" (102mm) Centers 0 0 0 0 0 1 PART: QTY: PROJECT: CONTACT: DATE: NOTES: APPROVAL: Dayton® Stainless Steel Single Bowl Top Mount Sink Model(s) GE12521 AMERICAN PRIDE, A LIFETIME TRADITION. Like your family, the Elkay family has values and traditions that endure. For almost a century, Elkay has been a family -owned and operated company, providing thousands of jobs that support our families and communities. Sinks are listed by IAPMO® as meeting the applicable requirements of the Uniform Plumbing Code, International Plumbing Code®, and National Plumbing Code of Canada. Product Compliance: ADA BUY AMERICAN ACT ASME A112.19.3/CSA B45.4 Clean and Care Manual (PDF) Installation Instructions (PDF) Limited Lifetime Warranty (PDF) Similar models are available with: drain in another location 21-1/4" (540mm) 15-3/4" (400mm) 2-1/4" R (57mm) 5-3/8" (137mm) In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design, quality, and functional benefits to the user. When making a comparison of other producers' offerings, be certain these features are not overlooked. Elkay REV 03062016 2222 Camden Court © 2016 elkay.com/qe12521 Oak Brook, IL 60523 GE12521_spec.pdf n Dimensions erator • Add 12" when stainless steel sinks are used. Job Specifications PRO Series Food Waste Disposers PRO 750 Evolution Series® Perfect for small households or restricted cabinet space. Submittal Sheet Perfect for small households or restricted cabinet space. • SoundSeal® technology delivers quiet performance versus a standard disposer. • MultiGrind° technology delivers 2 stages of grind vs.1 stage in standard disposer. • Includes sound -reducing Quiet Collar® Sink Baffle containing antimicrobial material. • Made in USA exclusively for professional plumbing contractors. Sample Specification Food Waste Disposer(s) shall be InSinkErator Model PRO 750® with MultiGrind° and SoundSeal® technologies, 3/4 HP motor, Auto -Reverse Grind System® feature and Stainless Steel Grind components. Warranty: We Come To You® 6-Year In -Home Limited Warranty. • The complete InSinkErator warranty is Included in the Care & Use Booklet packed with each unit. MADE INIr V@ LJSTED Disposers are designed and manufactured n the USA with over 80% domestic content / �tly se 1-800-558-5700 www.insi nkeratorcom FSC Specifications Type of Feed Continuous On/Off Control `Wall Switch Motor Single Phase HP 3/4 Reversing Auto -Reverse Grind System' feature Volts HZ 120 60 ' RPM 1725 Amp. (Avg. Load) 9.52 Time Rating Lubrication Intermittent Permanently Lubricated Upper & Lower Bearings Shipping Weight (Approx.) 19.2 lbs. Unit Finish Black Enamel Black 1 overall Height 12-1/4" SoundSeal Plus Anti -Vibration Mount° Technology Anti -Vibration Tailpipe Mount' Antimicrobial Quiet Collar• Sink Baffle LSoundLimiter" Insulation MultiGrind Technology GrindShear Ring. Grind Chamber Capacity 34.6 oz. Motor Manual Reset Protection Overload 1 Average Water Usage Approx.1 Gallon Per Person Per Day Average Electrical Usage 3-4 KWh Per Year Drain 1-1/2" Anti -Vibration Connection (Hose Clamp) Dishwasher Drain Connection Yes me ar,k a reeoomaMe wraary ev-COGae0Tts C ION Forest San,86M1p Cove./A.C. EMERSONO Commercial & Residential Solutions The Emerson logo is a trademark and service mark of Emerson Electrk Co. The mounting collar configuration Is a trademark of Emerson Electric Co. Ouick Lock° Is a registered trademark of Emerson Electric Co InSinkErator may make ewrovements and/or changes in the specifications at any tine, in its sole discretion, without notice or obligation and further reserves the right to change or discontinue models. P62415x•8310 Printed in U.SA. ® 2015 InsinkErator, tnSinkErator" is a business unit of Emerson Electric Co. All Rights Reserved. 2.50 021.86 (Center o Center of Rods) PAN ASSY 01. 2 PRODUCT SPECIFICATION DRAWING QUICK STAND"' #40-SWHP-A Suspended Water Heater Plafform (PVC) DRAIN BODY ASSY FULLY ASSEMBLED The Suspended Water Heater Platform is engineered to support water heaters up to 20 U.S. gallons (up to 375 pounds total weight). This time and labor savings tool is designed for the Professional Contractor. Design features requested by plumbers are incorporated into a professional platform that can be suspended with all thread rod. See Installation Instructions for detail. Product Information: Material: Pan: 14 gage CRS, galvanized Corner Brackets: 14 gage CRS, galvanized Wide platform allows water heaters up to 21-1/4" diameter Watertight corners and drain fittings eliminate need for additional drain pan Static load rating 375 pounds with 2X safety factor (depending on structural anchorage) Includes PVC drain body 1" MIPT x 1" FS Galvanized steel construction Suspends with user supplied 3/8" or 1/2" threaded rod and hardware Four corner attachment points allows for seismic/sway bracing connection Patent pending 1 HIS INFORMA I ION IS PROPRIETARY I 0 HOLDRI1 E AND IS SUBJEC TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. 1 Jj Product Submittal Job Name: Date: Part Number: Architect / Owner: Contractor: Notes: COM ZRTINI.1 MAKES ITT IVETIIODS INTO EMI !NEER= SOLITIO1V 800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / 1NWVV.HOLDRITE.COM spec_40-SWHP-A_RevE BRADFORD WHITE WATER HEATERS Residential Utility Electric Water Heater The Utility Electric Models Feature: • Fully Automatic Controls —Fast -acting surface -mount thermostat for automatic temperature control. Factory -installed sensitive manual reset energy cut-off for safety to prevent overheating. • Direct Heat Transfer With a Single Immersed Element —Transfers heat directly and efficiently to the water. Screw -in style element. • Vitraglae Lining —Bradford White tanks are lined with an exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglasi is fused to the steel surface by firing at a temperature of over 1600°F (871°C). • 1" Non-CFC Foam Insulation —Covers the sides and top of the tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies, and jacket rigidity. • Water Connections-3/4" NPT factory -supplied true dielectric fittings extend water heater life. Located on the side for easier installation (Fittings packaged separately inside carton). • Altemate Top Water Connections —The 6 and 12 gallon models have alternate 3/4" water connection tappings on top. • Protective Magnesium Anode Rod —Provides added protection against corrosion for long trouble -free service. • Voltages Available-120V, 208V, 240V, 277V, 480V. II Single Phase Operation Only. • T&P Relief Valve —Installed. • Design evaluated by ETL in accordance with Part 280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency. Photo is of RE112U6 t Copper Screw Type Immersion Element (Irtonloy type immersion element available upon request) ILIIDP .../ CERTIFIED 6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026:5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. VItraglas• Is a reglsierad trademark of Bradford White. Corporation, 1222-A-0316 Residential Electric Water Heater Utility Models C.E.C. Listed Model Number Capacity U.S. Imp. Gal. Gal. Recovery 90°F Rise U.S.* Imp' GPH GPH A Floor 10 Heater Top in. B Jacket Dia. in. C Floor to Hot Water Conn. in. D Floor to T&P Conn. in. E Floor to Cold Water Conn. in. F Floor to Anode Rod in. G Floor to Electrical Access in. Approx. Shipping Weight lbs. RE16116t 6 5 7 6 161/2 14 101/8 101h 31/6 161/2 161/a 35 RE110U6 10 8 7 6 171/2 16 15 14 511/16 911/16 12 44 RE112U6 12 10 7 6 167/8 18 101/4 101/4 3 161/2 167/8 53 RE112T6t 12 10 7 6 273/4 14 211/8 211/8 3 273/4 273/4 48 RE115U6 15 13 7 6 201/4 18 173/4 163/4 61/s 101/8 1211/16 58 RE120U6 19 16 7 6 243/4 18 181/4 181/4 3 101/4 243/4 65 Model Number Capacity Liters Recovery 50°C Rise Liters/" Hour A Floor to Heater Top mm. B Jacket Dia. mm. C Floor to Hot Water Conn. mm. 0 Floor to T&P Conn. mm. E Floor to Cold Water Conn. mm. F Floor to Anode Rod mm. G Floor to Electrical Access mm. Approx. Shipping Weight kg. RE16U6t 23 26 419 356 257 257 79 444 419 16 RE110U6 38 26 445 404 381 355 144 246 305 20 RE112U6 45 26 429 457 260 260 76 439 429 24 RE112T6t 45 26 705 356 537 537 76 730 705 22 RE115U6 57 26 514 457 451 425 156 257 322 26 RE120U6 72 26 629 457 464 464 76 260 628 29 tMaximum wattage at any voltage is 3000W. For 10 year models, change suffix "6" to "10". Single element only. "Based on 1500,W opesat on. PLUGTYPE ANODE 6 612 GAL ONLY ALTERNATE COLD INLET (PLUGGED) 6 612 GAL ONLY ALTERNATE HOT OUTLET (PLUGGED) 6 612 GAL ONLY 10 & 15 Gallon Models 6, 12, & 20 Gallon Models General: All models are exempt from NAECA requirements and ASHRAE Standard 90.1b. All models ETL listed. These heaters are wired Single Phase, 120V with one 1500W element, unless otherwise specified. All water and electrical connections are 3/4" (19mm) NPT. All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). Applicable models CSA-verified for energy performance in accordance with C191.1-M90. Wattage Recovery GPH Temperature Rise °F 60 80 90 100 120 1500W 2000W 2500W 3000W 3500W 4000W 4500W 5000W 5500W 6000W 10 8 7 6 5 14 10 9 8 7 17 13 11 10 9 21 15 14 12 10 24 18 16 14 12 28 21 18 16 14 31 23 21 19 15 34 26 23 21 17 38 29 25 23 19 41 31 28 25 21 Wattage Limitations Voltage 120V 208V 240V 277V 480V 1500W yes yes yes yes yes 2000W yes yes yes yes yes 2500W yes yes yes yes yes 3000W yes yes yes yes yes 3500W no yes yes no no 4000W no yes yes yes yes 4500W no yes yes yes yes 5000W no yes yes yes yes 5500W no yes yes no no 6000W no yes yes yes yes Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. BRADFORD WHITE' WATER HEATERS Ambler, PA For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 • Fax 215-641-1670 / Technical Support 800-334-3393 • Fax 269-795-1089 • Warranty 800-531-2111 • Fax 269-795-1089 International: Telephone 215-641-9400 • Telefax 215-641-9750 / www.bradfordwhite.com BRADFORD WHITE-CANADA' INC. Sales / Technical Support 866-690-0961 / 905-238-0100 • Fax 905-238-0105 / www.bradfordwhite.com Built to be the BestTM ©2016, Bradford White Corporation. All rights reserved. 1222-A-0316 Printed in U.S.A. • . aco ComfortilSdutions A Taco Family Company Effective: June 15, 2017 Submittal Data Information LeakBreaker® Water Heater Shut Off 101-178 Supersedes: August 1, 2016 Job: EngineerContractor: Rep: ITEM NO. MODEL NO. Features r Re-Settable Testable Quick Connect Wiring • Operates on Batteries or Power Supply Multi -Color LED Status Light Audible Alarm Alarm Mute 2 N/0; N/C Dry Contacts Full Port Valve Easy Removable Actuator Product Specifications Max. Operating Pressure 140 PSI Max. Shut Off Pressure 125 PSI Max. Static Pressure 300 PSI Maximum Ambient Temp 135°F Water Temp 33°F to 220°F Service Potable Water Flow Coefficient Cv 32 Kv 27.3 . _ Materials Control Panel High Performance Engineered Polymer Actuator Body High Performance Engineered Polymer Gears High Performance Internally Lubricated Engineered Polymer Valve Body Forged Brass Stem Brass Press Ring Brass Ball Brass (Chrome Plated) Seats Modified Teflon° 0-Rings Viton® Approval NSF Application The Taco LeakBreaker is installed on the incoming cold water supply to the water heater, shutting off the water to a leaking water heater. The plumb and plug design is specifically engineered for use on a new or retrofit installation. Components are pre -wired to simplify the installation process, just plug in the sensor, valve, power supply and/or batteries. LeakBreaker can be tested anytime and then be reset to guard against a future leak. LeakBreaker Valve Water Sensor LeakBreaker Module Power Cord - Hardware iili141.1t,r4Ziat41.!dra-r .C.Iral? 1110010 CornfortSolutions` • 47. LB-075-H-1LF 3/4" NPT A Taco Family Company Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436 3-3/16" IT COOU COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0010 DATE: 01/18/19 PROJECT NAME: WHITMORE LAW SITE ADDRESS: 6840 FORT DENT WAY - SUITE 210 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ow, ilrui-111 Building Division II sS AO— \—))---11 Public Works Fire Prevention Structural Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable 7 (no approval/review required) DATE: 01/22/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/19/19 Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg E] Fire D Ping D PW D Staff Initials: 12/18/2013 CITY PLUMBING INC Page 1 of 2 Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries !Search L&I A-Z latex Help My Workplace Richts Trades & Licensing CITY PLUMBING INC Owner or tradesperson Principals PAPERNIK III, JOSEPH S, PRESIDENT KNOWLES, SHELLY RAE, AGENT BERKMAN, RICHARD L, VICE PRESIDENT (End: 07/21/2010) Doing business as CITY PLUMBING INC WA UBI No. 602 218 839 11432 47th ave ne MARYSVILLE, WA 98271 360-454-0481 SNOHOMISH County Business type Corporation Governing persons RICHARD L BERKMAN JOE S III PAPERNIK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. CITYPI*955KJ Effective — expiration 05/11/2005— 08/08/2020 Bond Lexon Ins Co Bond account no. 9808230 Received by L&I 07/07/2011 Insurance Contractors Bonding & Insuranc Policy no. A31ADJ269 $6,000.00 Effective date 08/01/2011 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date 07/30/2018 08/01/2018 Expiration date 08/01/2019 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602218839&LIC=CITYPI*955KJ&SAW= 2/12/2019 CITY PLUMBING INC No savings accounts during the previous 6 k r,„eriod. Lawsuits against the bond or savings 7 \N. Page 2 of 2 No lawsuits against the bond or savings accounts during the previous 6 year period, L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 033,333-00 Account is current. Doing business as CITY PLUMBING INC Estimated workers reported Quarter 4 of Year 2018 "7 to 10 Workers" L&I account contact T3 / STEPHANIE HENDERSON (360)902-5598 - Email: HSTE235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Washington State DepL of Labor & Industries. Use of tbis site is subject in We laws of the stale of Washinoton, Help us improve haps://secure.lni.wa.gov/verify/Detail.aspx?UBI-602218839&LIC—CITYPI*9551CI&SAW= 2/12/2019 BUILDING INFORMATION 153 fn FL T ENT FORT DENT PARK 1.10.56.c.gE Ap5 LOCATION MAP NOT TO SCALE RE FORT DENT II 6840 FORT DENT WAY TUKWILA, WA 98168 PROJECT NORTH E II I FORT DENT II 6840 FORT DENT WAY TUKWILA, WA 98168 168 1D PROJECT TRUE. NORTH NORTH SITE ADDRESS: 6840 FORT DENT WAY TUKWILA, WA 98168. PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: BUILDING DESCRIPTION: DATE OF CONSTRUCTION: CONSTRUCTION TYPE: FIRE PROTECTION: NUMBER OF STORIES: 295490-0425 GUNDAKERS INTERURBAN ADD PARCEL 1 TGW POR OF PARCEL 2 DAF- BEG MOST WLY COR OF PARCEL 1 TH N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH SELY LN OF TRACT CONVEYED TO CITY OF TUKWILA RECORDING NO 7808230299 TH S 58-47-17 W 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79-7-SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN THE SW 1/4 OF NW 1/4 OF SECTION 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 RCM THREE-STORY OFFICE BUILDING WITH SURFACE PARKING LOT 1987 V-B FULLY SPRINKLERED 3 BUILDING TOTAL FLOOR AREA: ±19,933 SF (NO CHANGES) PROJECT DESCRIPTION INTERIOR TENANT IMPROVEMENT ON THE SECOND FLOOR OF AN EXISTING OFFICE SUITE TO INCLUDE: DEMISING A NEW OFFICE SUITE DEMOLITION OF PARTITIONS AND DOORS CONSTRUCTION OF PARTITIONS, BREAK ROOM AND DOORS NO STRUCTURAL WORK OR ALTERATION OF CORE MECHANICAL, PLUMBING, ELECTRICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER SEPARATE PERMITS BY DESIGN BUILD CONTRACTORS - DEFERRED SUBMITTALS SEPARATE PERMIT R UIREC3 FOR: Mecharricel Electrical ❑ Plumbing [� Gas Piping City of Tukwila BUILDING DIVISION PROJECT AREA SUITE AREA FLOOR AREA FLR #2 3,256 SF 3,256 SF (NO CHANGES) ±19,933 (NO CHANGES) APPLICABLE CODES BUILDING: EXISTING BUILDING: FIRE: PLUMBING: MECHANICAL: GAS PIPING: ELECTRICAL: ENERGY: ACCESSIBILITY: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL FUEL GAS CODE (IFGC) 2017 NATIONAL ELECTRICAL CODE (NEC) 2015 WASHINGTON ENERGY. CODE (WSEC) ICC/ANSI 117.1-20t)9 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES PROJECT DIRECTORY TENANT: WHITMORE LAW BUILDING REPRESENTATIVE: ARCHITECT: CONTRACTOR: JOHN C RADOVICH DEVELOPMENT 2835 82ND AVENUE SE, MERCER ISLAND, WA 98040 PHONE: 206-267-2669 EMAIL: REBECCADAVIDSON@JCRDEVCO.COM CONTACT: REBECCA DAVDISON NELSON 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: 206-408-8500 EMAIL: LDUCEY@nelsononline.com CONTACT: LINDA DUCEY DP INCORPORATED GENERAL CONTRACTORS 19936 BALLINGER WAY NE, SEATTLE, WA 98155 PHONE: 206-361-2989 EMAIL: VASILY@DPINC.NET CONTACT: BILLY SHADRIN DRAWING INDEX SHEET NUMBER SHEET ISSUE DATE DRAWING REVISION NUMBER REVISION ISSUE DATE SHEET TITLE GENERAL AN-0 COVER SHEET 12/19/18 AN-1 LIFE SAFETY PLAN 12/19/18 AN-2 GENERAL NOTES, ABBREVIATIONS & SYMBOLS 12/19/18 ARCHITECTURAL A1-1 DEMOLITION & CONSTRUCTION PLANS 12/19/18 A2-1 REFLECTED CEILING PLAN 12/19/18 A7-1. ELEVATIONS & CASEWORK DETAILS 12/19/18 A9-1 PARTITION TYPE 12/19/18 Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, LLC 1200 Fifth Ave. Suite 1300 Seattle, WA 98101 Phone: (206) 223-4999 Fax: (206) 223-4990 REVISIONS No changes shall be made to the scope of work without pn, r approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may Include additional plan review. FIL Permit No. Plan review approval is subject to errors ana omissions Approval of construction documents does of Guth raze the violation of any a. soled • e or ordinance. IRA02i, of approve' F : Id Coo y�rY�'"" Sis.G.o/I..•-C: By. Milk• // ad //� A ,1. ,/ Date* i �ii1 G v of uK iia BUILrING DIVISION Tfttib consultants Description: PERMIT SET revisions No: By: Date: BMT 12/19/18 FORT DENT II BUILDING 6840 FORT DENT WAY TUKWILA, WA 98168 client WHITMORE LAW 2ND FLOOR, SUITE 210 6840 FORT DENT WAY TUKWILA, WA 98168 project name & address COVER SHEET sheet title RECEIVED CITY OF TUKWILA JAN 18 2019 PERMIT CENTER seal REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2019 A-J City of Tukwila BUILDING DIVISION Proj. No: 18.04807.00 Drawn By: Project Manager: LD Reviewed By: Designer: BMT Approved By: AN-0 BMT LD AS ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUBCONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, LLC 2018 ALL RIGHTS RESERVED Full size=24"x36"/ Half size =1.2"x1.8"/11_"x1.7"=NTS CONSTRUCTION GENERAL NOTES DEMOLITION GENERAL NOTES Plot Date: 12/19/2018 3:06:22 PM Filename: U:\Proj\JCR Development Company\WA\Fort Dent II\18.04807.00-Whitmore Law - Fort Dent II\DRAWINGS\ARCH\3_CD\Permit Set\FDII-WHIT-A1-1_DEMO_CONSTRUCTION.dwg User: Brittany Toshi Device: _DWG To PDF.pc3 PenTable: _NELSON-FULL.ctb Tj DEMOLITION PLAN SCALE: 1/8" = 1'-0" CONFERENCE I 202 CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" _yr RECEPTION I 201 2'-3" EQ, 5'-0' E TELECOM/STORAGE WORK ROOM ji REAK ROOM OFFICE /////// /////////�',. /// ////////://///////° ' / //// _ 0 4' 8' 16' SCALE: 1/8" = 1'-0" //////////////74Z/ ///////,!/� //////''/ ////////./_ OFFICE (E) OFFICE 205 4' 8' (E) OFFICE I 208 (E) OFFICE I 207 (E) OFFICE 206 16' El) SCALE: 1/8" = 1'-0" DEMOLITION & CONSTRUCTION PLAN LEGEND NOT IN CONTRACT (NIC) ......, EXISTING CONSTRUCTION TO REMAIN _ = _ = = EXISTING PARTITION TO BE REMOVED NEW B/S PARTITION i EXISTING DOOR TO BE REMOVED. SALVAGE FOR RELOCATION OR RETURN TO BUILDING INVENTORY EXISTING DOOR TO REMAIN (R) = RELOCATED DOOR (G) = MAXIMUM GLASS INSERT TO BE INSTALLED NEW UPPER & LOWER CASEWORK I ALIGN (E) EXISTING DEMOLITION & CONSTRUCTION 10 PLAN KEYNOTES 101 IF REQUIRED BY OWNER, UPGRADE EXISTING WALL PARTITION WITH SOUND INSULATION FOR DEMISING WALL. 102 PATCH AREAS OF DEMOLITION AND PREP FOR NEW PAINT, CARPET AND WALL BASE, TO MATCH EXISTING. 103 FURR OUT WALL, PROVIDE NEW COLD WATER LINE, ELECTRICAL, PLUMBING AS NEEDED FOR BREAK ROOM. 104 CONFIRM WITH TENANT IF COLD WATER LINE IS NEEDED FOR REFRIGERATOR. 105 EXISTING WALLS WITH REVEAL, SKIM COAT ENTIRE WALL TO A LEVEL 4 FINISH. 106 CONTRACTOR TO PROVIDE AND INSTALL STANDARD HEIGHT DISHWASHER, PROVIDE COLD WATER LINE. 107 INFILL WALL TO MATCH EXISTING WALL THICKNESS, PREP AND PATCH GWB TO MATCH WALL CONDITIONS. 1. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 2. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE AND IN PROPER ALIGNMENT, U.N.O. 3. ALL DIMENSIONS ARE TO FINISH CONSTRUCTION, U.N.O. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. DIMENSIONS MARKED ± MEAN A VARIANCE NOT GREATER THAN 1 INCH, VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE FINISH FACE OF WALL BELOW SILL, U.N.O. 4. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS, AND CORRIDOR WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT SURFACES. 5. PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING SLABS, WALLS AND SHAFTS, SEAL ABANDONDED PENETRATIONS AT FLOORS, WALLS AND SHAFTS TO MAINTAIN FIRE/SMOKE AND ACOUSTICAL RATINGS. PATCH FIREPROOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED STRUCTURAL STEEL. 6. WHERE PARTITIONS ARE ATTACHED TO CURTAIN WALL, CENTER PARTITIONS ON WINDOW MULLIONS, PERPENDICULAR TO PERIMETER WALL, U.N.O. CONSTRUCTION TO MATCH BUILDING STANDARD. 7. EXTEND GYPSUM WALLBOARD AND FRAMING AT EXISTING PARTITIONS AND COLUMNS, TO 6" (MINIMUM) ABOVE SUSPENDED CEILING WHEN NEW CEILING HEIGHTS ARE ABOVE THE EXISTING CEILING HEIGHT. 8. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTION. 9. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH, U.N.O. - REFER TO MATERIAL SCHEDULE & FINISH PLAN FOR MATERIALS & LOCATIONS THAT REQUIRE A LEVEL 5 FINISH, U.N.O. 10. REFER TO THE PARTITION TYPES FOR PARTITION THICKNESS. 11. CONSTRUCTION OF FIRE -RATED PARTITIONS, INCLUDING TAPING AND FINISHING OF GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE, SHALL BE IN ACCORDANCE WITH UL SPECIFICATIONS TO ACHIEVE RATING INDICATED. 12. WHERE PARTITIONS EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING, SECURE THE TOP TRACK TO THE EXPOSED CEILING GRID. PROVIDE A COMPRESSIBLE GASKET BETWEEN THE TOP TRACK AND THE CEILING GRID. PROVIDE TAPABLE METAL J-BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6'-0" AND NO JOINTS GREATER THAN 3/16", U.N.O. CAULK PERIMETER AT TOP OF GWB. 13. PROVIDE GROUNDS AND BLOCKING IN METAL STUD WALL FRAMING FOR SUPPORT OF CASEWORK, SHELF -STANDARDS, A/V DEVICES, FURNITURE, ETC. ALL CONCEALED LUMBER AND BLOCKING TO BE FIRE TREATED. COORDINATE BLOCKING REQUIREMENTS WITH FURNITURE & AV INSTALLERS. WHERE BLOCKING OR ADDITIONAL STUDS ARE REQUIRED AT EXISTING PARTITIONS, THEY ARE TO BE PATCHED AND REPAIRED. SEE CONSTRUCTION PLANS FOR WALL -MOUNTED MARKERBOARD, MONITORS & PROJECTION SCREENS; PROVIDE BLOCKING PER MANUFACTURERS' REQUIREMENTS. 14. ALL HINGED DOORS TO BE 4" FROM NEAREST PERPENDICULAR PARTITION, U.N.O. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. ALL DOORS SHALL HAVE 1'-6" CLEAR ON THE STRIKE/PULL SIDE OF DOOR AND 1'-0 CLEAR ON THE STRIKE/PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A CLOSER) VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 15. PROVIDE VERTICAL CONTROL JOINTS 30' O.C. MAX. IN ALL GWB PARTITIONS LONGER THAN 30'. WHEN POSSIBLE CONTROL JOINTS SHOULD BE LOCATED ABOVE THE CORNER OF A DOOR. 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVAL OF EXISTING CONSTRUCTION AND THE STORAGE AND REMOVAL OF SAID CONSTRUCTION, AND SHALL MAINTAIN THE AREA OF CONSTRUCTION IN A CLEAN AND ORDERLY CONDITION WITH DAILY REMOVAL OF DEBRIS. COORDINATE REMOVALS OF OTHER TRADES; REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL SCOPE. 2. COORDINATE SCOPE OF DEMOLITION/REMOVAL WITH THE SCOPE OF NEW WORK. 3. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING AND REPAIRING REQUIRED TO PERFORM THE WORK INDICATED ON THE DRAWINGS. ALL CUTTING AND REMOVALS SHALL BE DONE NEATLY. 4. ALL ITEMS TO BE REMOVED AND SCHEDULED FOR REINSTALLATION OR TO BE RETURNED TO THE BUILDING SHALL BE PROTECTED, CLEAN AND FREE OF DEFECTS. FOR ITEMS SCHEDULED FOR REMOVAL AND REINSTALLATION, CONTRACTOR SHALL VERIFY AND DOCUMENT, IN WRITING, THE CONDITION AND FUNCTIONALITY OF THE ITEM(S) PRIOR TO REMOVAL. ANY DAMAGE TO ITEM(S) NOT DOCUMENTED SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 5. NO DEBRIS SHALL BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF REMOVALS. 6. ERECT AND MAINTAIN DUSTPROOF BARRIERS TO PREVENT THE SPREAD OF DUST, FUMES, SMOKE, ETC. TO OTHER PARTS OF THE FLOOR OR BUILDING. UPON COMPLETION OF WORK, REMOVE BARRIERS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT. PROTECT HVAC SYSTEM FROM DUST & DEBRIS. CONTRACTOR TO PROVIDE FILTER MEDIA TO COVER THE MAIN RETURN AIR GRILLES. PROVIDE NEW AIR FILTERS AT MECHANICAL UNITS AT THE COMPLETION OF CONSTRUCTION. 7. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. ANNOYANCES AND DISTURBANCES TO OTHER OCCUPANTS, PERSONNEL AND EMPLOYEES SHALL BE KEPT TO THE MINIMUM NECESSARY FOR THE PERFORMANCE OF THE WORK. 8. IN AREA OF WORK REMOVE ALL ABANDONED WIRING BACK TO ELECTRICAL PANELS. COORDINATE REUSE OF FREED CIRCUITS. PROVIDE TEMPORARY LIGHT AND POWER DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE ELECTRICAL MAKE -SAFE DURING REMOVALS AND CONSTRUCTION. 9. REMOVE DOORS, FRAMES, AND HARDWARE AS NOTED AND SAVE FOR REINSTALLATION U.N.O. 10. EXISTING CEILING GRID TO REMAIN, U.N.O. MODIFY TO ACCOMMODATE NEW PARTITIONS. 11. SALVAGE FIRE ALARM DEVICES, EXIT SIGNS, LIGHTING AND HVAC DEVICES THAT ARE SCHEDULED FOR REMOVAL FOR REUSE, U.N.O. 12. NO STRUCTURAL ELEMENTS SHALL BE REMOVED. ?(11- D Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, LLC 1200 Fifth Ave. Suite 1300 Seattle, WA 98101 Phone: (206) 223-4999 Fax: (206) 223-4990 consultants Description: PERMIT SET revisions No: By: Date: BMT 12/19/18 DEVELOPMENT; client FORT DENT II BUILDING 6840 FORT DENT WAY TUKWILA, WA 98168 WHITMORE LAW 2ND FLOOR, SUITE 210 6840 FORT DENT WAY TUKWILA, WA 98168 project name & address DEMOLITION & CONSTRUCTION PLANS sheet title RECEIVED CITY OF TUKWILA JAN182019 PERMIT CENTER seal 1 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2019 City of Tukwila BUILDING DIVISION Proj. No: 18.04807.00 Project Manager: LD Designer: BMT Drawn By: Reviewed By: Approved By: Al-1 BMT LD AS ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, LLC 2018 ALL RIGHTS RESERVED Full size = 24" x 36" / Half size = 1.2" x 18" / 11" x 17" = NTS 1'-2" SEE ELEVATION SEE ELEVATION INTERIOR: ALL SIDES PL-X / LINE OF CEILING SCHEDULED PARTITION ADJUSTABLE SHELVES: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD; (2) SHELVES PER CABINET U.N.O. / 2'-0" SEE ELEVATION J INTERIOR: ALL SIDES PL-X 0 -I EDGE OF MILLWORK BEYOND FRENCH CLEATS 4"H BACKSPLASH TO MATCH COUNTERTOP WHERE OCCURS (SEE ELEVATION) COUNTERTOP: PLASTIC LAMINATE ON 3/4" THICK PARTICLE BOARD APRON: PLASTIC LAMINATE.ON 3/4" PARTICLE BLOARD ADJUSTABLE SHELVES: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD; (1) SHELVES PER CABINET U.N.O. EDGE OF MILLWORK BEYOND FRAME: 3/4" PARTICLE BOARD; ADD FRTQ BLOCKING AS REQUIRED SCHEDULED BASE LINE OF FINISHED FLOOR SEE ELEVATION UPPER OPEN CASEWORK, TYP. COUNTERTOP & 4"H BACKSPLASH, TYP. SEE RCP 1'-0" • 1/2" MIN. INTERIOR: 2" WHITE MELAMINE 1" 2 .`1 t' ''`i 1 SCHEDULED CEILING SCHEDULED PARTITION DOOR: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD ADJUSTABLE SHELVES: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD; (2) SHELVES PER CABINET U.N.O. SEE ELEVATION 2'-0" 4 COMPACT DISPOSAL: INSINKERATOR BADGER 5 I INTERIOR: WHITE MELAMINE I 6" 3 4 • * — I EE ELEVATION SCHEDULED HARDWARE PROVIDE SILENCER, TYPICAL FRENCH CLEATS SCHEDULED PARTITION 4" BACKSPLASH TO MATCH COUNTERTOP WHERE OCCURS (SEE ELEVATION); PROVIDE CLEAR SEALANT AT WET LOCATIONS WHERE BACKSPLASH IS NOT SPECIFIED COUNTERTOP: PLASTIC LAMINATE ON 3/4" THICK PARTICLE BOARD PROVIDE 'RAKKS' CLEAT @ SIDE WALL IF NO ADJACENT CABINETS ARE AVAILABLE FOR COUNTERTOP SUPPORT; PROVIDE 'RAKKS' CONCEALED BRACKET AT ANY OPEN ENDS AND AT ANY UNSUPPORTED LENGTHS GREATER THAN 36". SCHEDULED HARDWARE PROVIDE VALVE FOR WATERLINE SUPPLY APRON & DOOR: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD; PROVIDE INTEGRAL TOEKICK LINE OF FINISHED FLOOR, CONTINUE TO WALL LOWER OPEN CASEWORK, TYP. BASE TO MATCH CASEWORK / EQ. / EO. / EQ. EQ. WORK ROOM ELEVATION SCALE: 3/8" = 1'-0" SEE RCP SCHEDULED CEILING 2'-0" P I L_ t r INTERIOR: WHITE MELAMINE • P r r' r •1` ,k . r, ALL SIDES: PL-X ALL SIDES: PL-X ALL SIDES: PL-X SCHEDULED PARTITION DOOR: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD SCHEDULED HARDWARE FINISHED END PLAN TO ALIGN WITH COUNTERTOP COORDINATE ACCESS TO ELECTRICAL OUTLETS AT FACE OF CASEWORK LINE OF FINISHED FLOOR ,/- SEE ELEVATION 2'-9" • • / a a/ 3'-0" MIN. CLR \ T N / OP( N / N 0 0 BREAK ROOM ELEVATION SCALE: 3/8" = 1'-0" 2'-0" 0 M 2'-0" MIN. CLR SCHEDULED PARTITION 4" BACKSPLASH TO MATCH COUNTERTOP WHERE OCCURS (SEE ELEVATION); PROVIDE CLEAR SEALANT AT WET LOCATIONS WHERE BACKSPLASH IS NOT SPECIFIED COUNTERTOP: �� PLASTIC LAMINATE ON 3/4" THICK PARTICLE BOARD. DRAWER: PLASTIC LAMINATE ON Am 3/4" PARTICLE BOARD FRONT WITH 1/2" HARDWOOD SIDES AND 1/4" HARDWOOD BOTTOM RECEIVED —�� SCHEDULED HARDWARECITY OF TUKWILA 0 ,1 = Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, LLC 1200 Fifth Ave. Suite 1300 Seattle, WA 98101 Phone: (206) 223-4999 Fax: (206) 223-4990 consultants Description: PERMIT SET revisions No: By: Date: BMT 12/19/18 R client FORT DENT II BUILDING 6840 FORT DENT WAY TUKWILA, WA 98168 WHITMORE LAW 2ND FLOOR, SUITE 210 6840 FORT DENT WAY TUKWILA, WA 98168 project name & address ELEVATIONS & CASEWORK DETAILS sheet title 0 0 INTERIOR: WHITE MELAMINE FRAME. 3/4" PARTICAL BOARD; ADD FRTW BLOCKING AS REQUIRED 0 0 ADJUSTABLE SHELVES: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD; (1) SHELF PER CABINET U.N.O. DOOR: PLASTIC LAMINATE ON 3/4" PARTICLE BOARD SCHEDULED BASE LINE OF FINISHED FLOOR JAN182019 PERMIT CENTER seal REVIEV'tiED FOR CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION Proj. No: 18.04807.00 Project Manager: LD Designer: BMT Drawn By: Reviewed By: Approved By: A7-1 BMT LD AS WORK ROOM CASEWORK DETAIL SCALE: 1-1/2" = 1'-0" BREAK ROOM CASEWORK DETAIL SCALE: 1-1/2" = 1'-0" BREAK ROOM FULL -HEIGHT CASEWORK DETAIL SCALE: 1-1/2" = 1'-0" BREAK ROOM CASEWORK DETAIL SCALE: 1-1/2" = 1'-0" Full size = 2 " x 36" / Half size = 12" x 18" / 11" x 17" = NTS ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, LLC 2018 ALL RIGHTS RESERVED Indirect Drain waste line tied to existing 2 " waste 2" 111 2 Way te D'ag�a clean out z cold water tied to building cold water expansion tank 6 gallon water heater Wa r Diag�a trap primer 1M 11432 47th Ave NE Marysville, Wa 98271 Phone 360-454-0481 Fax 360-454-0485 jpapernik@cityplumbing,org d 3 d L o 0 o V- J d +' Y • CO Wa 98188 DATE: 1/17/19 RECEIVED CITY OF TUKWILA JAN 18 2019 PERIVI WD CODE COMPLIANCE APPROVED Plumbing sink diagram FEB 0'2 2019 City of Tukwila UILDING DIVISION P 0