PLUMBING/GAS PIPING PERMIT
1023049082 Permit Number: PG19'0013
Issue Date: 2/7/2019
Permit Expires On: 8/6/2019
Project Name: SABEY
Address:
Contact Person:
Address:
SABEY CORPORATION
12ZO1TUKVv|LA|NTLDLVD4THFL,
KAYLENE NELSON
Contractor:
Name: MERMAN5ONCOMPANY iLP
(GENERAL)
Address: lZZ1ZNDAVE N'KENT,WA, 9B0]Z'
2945
License No: HERMACLO05BJ
Address-
^''
Phone: QEA359-7147
Phone: (206)579'9700
Expiration Date: 8/25/2020
DESCRIPTION gFWORK:
ADDING 2 FLOOR DRAINS
Valuation of Work: $5,000-00
Water District: 125
5ewerDisthct: VALLEYV|EVV
Fees Collected: $158.00
Current Codes adopted bythe City ofTukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
20152015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
VVACZ96'4013:
Code:
ermit Center Authorized Signature:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:,
Print Name:
Gl)GE
Date:-247 )
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 gauge.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
8004 GROUNDWORK
1900 PLUMBING FINAL
CITY OF TUKWIC
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Gas Permit No.
Project No.
Date Application Accepted: t 17 19
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 102304-9082
Site Address:
Tenant Name:
Sabey
Suite Number: t—V2-612
PROPERTY OWNER
Name: Sabey
Address: 12201 Tukwila International BLVD
City: Tukwila State: WA Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name:
Address: 1221 2nd Avenue N
City: Kent State: WA
Zip: 98032
Phone: (253) 359-7147 Fax:
Email: kaylene.nelson@heiiiianson.com
Floor:
New Tenant: fl Yes LI ..No
PLUMBING CONTRACTOR INFORMATION
Company Name: Hermanson Company
Address: 1221 2nd Avenue N
City: Kent State: WA Zip: 98032
Phone: (253) 359-7147 Fax:
Contr Reg No.: HERMACL005133 Exp Date: 08/25/2020
Tukwila Business License No.: BUS-0994464
Valuation of Project (contractor's bid price): $ 5,000
Scope of Work (please provide detailed information):
Adding (2) Floor Drains
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
HAApplications1Forms-Applications On Line \20 I 1 Applications \Plumbing Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity elow: ow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent dram
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric-typc vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
—
Fixture Type
—
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mrn) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
2
Reccptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT,
BUILDING 1 1 ER 0 L A AG N
Signatur
Print Name:
Mailing Address: 1
Date:
Day Telephone: -71 1/4-1
k) KP (1\--
City State Zip
H:\AppIications\Forr-AppIications On Line \201I Applications \Plumbing Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$158.00
PG19-0013 Address: 3355 5 120TH PL'120
Apn:1023049082
$158.00
Credit Card Fee
$4.60
Credit Card Fee
R000.369.908.00.00
0,00
$4.60
PLUMBING
$147.50
PERMIT FEE
R000.322.100.00.00
0.00
$83,00
PERMIT ISSUANCE BASE FEE
R000,322.100.00,00
0.00
$35.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$29.50
TECHNOLOGY FEE
$5.90
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R16580
R000.322.900.04.00 0.00
$5.90
$158.00
Date Paid: Tuesday, January 22, 2019
Paid By: KAYLENE NELSON
Pay Method: CREDIT CARD 529615
Printed: Tuesday, January 22, 2019 12:23 PM 1 of 1
SYSTEMS
CO TVxWILA ETK4KIT
5280 SOUTH[ENTED 8LVD
TUKWILA, W& 98188
206'433'1870
CITY OF TUKWILA
0017340008802374404508
Date: 0I/22/2819 I2:23:0I PM
CREDIT CARD SALE
VISA
CARD NUMBER: *****^****8057 K
TRxN AMOUNT: $158.00
APPROVAL [D: 529615
RECORD #: 000
CLERK ID: 1azzel
{CARDHOLDER'S SIGNATUnE\
I AGREE TO PAY THE ABOVE TOTAL AMOUNT
ACCORDING TO THE CARD ISSUER AGREEMENT
(MERCHANT AGREEMENT IF CREDIT VOUCHER)
Thank you!
Merchant Copy
CO TUKWIL4 ETR4KIT
0200 S0UTH[ENTER BLvo
TUKWIL4, WA 98188
2e6'433-1870
CITY OF TUKWIUu
Date: 0I/22/2019 12:23:01 PM
[xsozT CARD SALE
VISA
[4RQ NUMBER: ********^*0057 K
THAN AMOUNT: $158.00
APPROVAL [D: 529615
RECORD #: 000
CLERK ID: jazzel
Thank you!
Customer Copy
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit inspection Request Line (206) 438-9350
'9 091
Project:
-Type nspection:
. -piAA,e.,
Date Called:
64,bq
Address:
33 Sc 6 i ap-114
cs L_
Special Instructions:
'Date
Wanted:
Z-2s
¶P.
•
4
•
Requester:
---C-41--61-
Phone No:
?
pproved per applicable codes. D Corrections required prior to approval.
COMMENTS:
Inspector:
Date:
z-te
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
PERMIT COCD COFP)
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG19-0013
PROJECT NAME: SABEY
SITE ADDRESS: 3355 S 120 PL
X Original Plan Submittal
Response to Correction Letter #
Revision #
Revision #
DATE: 1/22/19
before Permit Issued
after Permit Issued
DEPARTMENTS:
M 11-221
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator III
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 1/24/19
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CO
Approved
Corrections Required
CTIONS:
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 2/21/19
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping El PW 0 Staff Initials:
12/18/2013
Borne 1.,.l.,-;nanol Contact
Safety & Health Claims & Insurance
Washington State Department oi
Labor & industries
A-Z Inclnx Help My 1.&1
Workplace Rights Trades & Licensing
HERMANSON COMPANY LLP
Owner or tradesperson
Principals
NICOLAISEN, KNUT H, PARTNER/MEMBER
BROCK, DANIEL L, PARTNER/MEMBER
FOX, DEAN M, PARTNER/MEMBER
HENGEL, STEPHEN A, PARTNER/MEMBER
DYCKMAN, KENNETH
A, PARTNER/MEMBER
ROBINETT, PAUL J, PARTNER/MEMBER
HERMANSON, RICHARD
L, PARTNER/MEMBER
ALMON, KEVIN, PARTNER/MEMBER
(End: 08/05/2010)
MACDONALD, JAMES, PARTNER/MEMBER
(End: 08/05/2010)
Doing business as
HERMANSON COMPANY LLP
WA UBI No.
602 004 844
1221 2ND AVE N
KENT, WA 98032-2945
206-575-9700
KING County
Business type
Limited Liability Partnership
Governing persons
CORP
HERMANSON
LLC HERMANSON GROUP;
License
Verify the contractors active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
HERMACLOO5BJ
Effective — expiration
01/11/2000— 08/25/2020
Bond
...
WESTERN SURETY CO
Bond account no.
929381801
$12,000 00
Received by L&I Effective date
12/01/2005 01/01/2006
Expiration date
Until Canceled
Help us improve
Insurance
Transportation Ins Co
Policy no.
6043050846
$1,000,000,00
Received by L&I Effective date
08/16/2018 08/21/2018
Expiration date
08/21/2019
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
Account is current.
L&I Account ID
409,648-01
Doing business as
HERMANSON COMPANY LLP
Estimated workers reported
Quarter 4 of Year 2018 "Greater than 100 Workers"
L&I account contact
T4 / TERRI MADISON (360)902-4654 - Email: KIRT235@Ini.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for.
Inspection results date
09/13/2018
Inspection no,
317950430
Location
3855 Montevilla Pkwy
Bothell, WA 98021
Inspection results date
05/22/2018
Inspection no.
317948819
Location
1221 2nd Ave N
Kent, WA 98032
Inspection results date
03/05/2018
Inspection no.
317948149
No violations
Violations
No violations
Help us improve
Location
635 Park Ave N
Renton, WA 98057
Inspection results date
02/23/2016
Inspection no.
317939295
Location
15580 NE 31st St.
Redmond, WA 98052
Inspection results date
05/21/2015
Inspection no.
317935231
Location
4480 154th PI NE
Redmond, WA 98052
Inspection results date
12/10/2014
Inspection no.
317424935
Location
21601 76th Ave W.
Edmonds, WA 98026
Inspection results date
05/17/2013
Inspection no.
316772151
Location
955 Broadway
Tacoma, WA 98402
No violations
No violations
No violations
Violations
Washington State Dept of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
A
AAV
ABS
ABV
AC
AD
ADD/ADD'L
ADJ
AFF
AFG
AP
ARCH
ASME
ATM
BHP
BLDG
BOP
BOT
BS
BTU
BTUH
COND
CA
C TO C
CAP
CB
CENT
CFF
CFM
CI
CLG
CMU
CO
CO2
COL
CONC
COND
CONN
CONT
CONTR
COORD
CPVC
CT
CU
CW
DCVA
DDC
DEG
DI
DIA
DIFF
DISCH
DN
DOM
DR
DS
DWG
DWV
EA
EFF
EL
ELEC/ELECT
EMER
ENT
EQUIP
ERW
ES
ET
EWC
EWT
� IpST/(E)
EXT
F
FA
FCO
FD
FDN
FF
FFD
FIC
FIO
FLEX
FLR
FOIC
FP
FPM
FPS
FPWH
FS
FT
GA GAL
GAUV
GD
GC
GEN
GND
GPH
GPM
HB
HD
HDR
HG
HORIZ
HOA
HP
HR
HT
HW
HWC
HX
HZ
A
BC
CW
D
E
N
N WG
NSUL
PLUMBING / PIPING ABBREVIATIONS
AIR/COMPRESSED AIR
AIR ADMITTANCE VALVE
ACRYLONITRITE BUTADIENE STYRENE
ABOVE
AIR COMPRESSOR
ACCESS /ONAL DOOR/AREA DRAIN/AIR DRYER
ADDITION
AD ACENT/ADJUIST/ADJUSTABLE/ADJUSTMENT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ACCESS PANEL
ARCHITECT
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ATMOSPHERE ATMOSPHERIC
BRAKE HORSEPOWER/BOILER HORSEPOWER
BUILDING
BOTTOM OF PIPE
BOTTOM
BLACK STEEL
BRITISH THERMAL UNIT
BRITISH THERMAL UNITS PER HOUR
CONDENSATE
COMPRESSED AIR
CENTER TO CENTER
CAPACITY/END CAP
CATCH BASIN
CENTRIFUGE/CENTRIFUGAL
CAP FOR FUTURE
CUBIC FEET PER MINUTE
CAST IRON
CEILING
CONCRETE MASONRY UNIT
CLEANOUT/COMPANY/CARBON MONOXIDE
CARBON DIOXIDE
COLUMN
CONCRETE
CONDENSATE
CONNECT/CONNECTED/CONNECTION
CONTINUOUS CONTINUATION
CONTRACTOR
COORDINATE
CHLORINATED POLYVINYL CHLORIDE
COOLING TOWER
CUBIC/COPPER/CONDENSING UNIT
DOMESTIC COLD WATER
DOUBLE CHECK VALVE ASSEMBLY
DIRECT DIGITAL CONTROL
DEGREE/DEGREES
DEIONIZED WATER
DIAMETER
DIFFERENTIAL/DIFFERENCE/DELTA
DISCHARGE
DOWN
DOMESTIC
DRAIN
DOWNSPOUT
DRAWING
DRAIN, WASTE AND VENT
EACH
EFFICIENCY
ELEVATION
ELECTRICAL ELECTRIC
EMERGENCY
ENTERING
EQUIPMENT
ELECTRIC RESISTANCE WELDED
EMERGENCY SHOWER
EXPANSION TANK
ELECTRIC WATER COOLER/
EVAPORATIVE WATER COOLER
ENTERING WATER TEMPERATURE
EXISTING
EXPANSION/EXPOSED/EXPLOSION PROOF
EXTERNAL/EXTERIOR
FAHRENHEIT FEED/FILTER
FACE AREA FIRE ALARM
FLOOR CL N OUT
FLOOR DRAIN
FOUNDATION
FINISH FLOOR
FUNNEL FLOOR DRAIN
FURNISHED AND INSTALLED BY CONTRACTOR
FURNISHED AND INSTALLED BY OWNER
FLEXIBLE
FLOOR
FURNISHED BY OWNER INSTALLED BY OTHERS
FREEZE PROOF/FIRE PROTECTION
FEET PER MINUTE
FEET PER SECOND
FREEZE PROOF WALL HYDRANT
FLOOR SINK, FLOW SWITCH
FOOT/FEET
GALLON
GALVANIZED
GARAGE DRAIN/GARBAGE DISPOSAL
GENERAL CONTRACTOR
GENERAL
GROUND
GALLONS PER HOUR
GALLONS PER MINUTE
HOSE BIBB
HEAD
HEADER
MERCURY
HORIZONTAL
HAND -OFF -AUTOMATIC
HORSEPOWER
HOUR
HEIGHT HEAT TRACE
DOMESTIC HOT WATER
DOMESTIC HOT WATER CIRCULATING
HEAT EXCHANGER
HERTZ
NSTRUMENT AIR
NTERNATIONAL BUILDING CODE
NDUSTRIAL COLD WATER
NSIDE DIAMETER DIMENSION
NVERT ELEVATION
NCH/INCHES
NCHES WATER GAUGE
NSULATE/INSULATION
INV INVERT
IRW IRRIGATION WATER
IW INDIRECT WASTE
KWH KILOWATT HOUR
KEC KITCHEN EQUIPMENT CONTRACTOR
LAV LAVATORY
LB/LBS POUND/POUNDS
LBS/HR POUNDS PER HOUR
LPG LIQUID PROPANE GAS
LPS LOW PRESSURE STEAM
LWT LEAVING WATER TEMPERATURE
MAX
MBH
MCA
MECH
MFR
MIN
MISC
MM
MPS
MTD
NA
NC
NG
NIC
NO
NO2
NOM
NP
NTS
02
OC
OD
ODP
ORD
OVHD
PD
PERF
PH
PLBG
POC
PRESS
PRV
PS
PSF
PSI
PSIG
PVC
QTY
R
RCVR
RD
RECIRC
REF
REG
RL
RPBP
RPM
RS
RV
RVD
S
SAN
SAT
SD
S_C
SECT
SO
SOL
SOLV
SP
SPEC
SQ FT
SS
STRUC
SUCT
TBD
TD
TEMP
THERM
TOP
TP
TPS
TYP
UG
UNO
UPC
UR
UTIL
V
VA
VAC
VB
VEL
VERT
VOL
VR
VTR
W/
W/0
WAGD
WC
WCO
WH
WLD
WM
WO
WP
WR
WT
WWP
MAXIMUM
1000 BRITISH THERMAL UNITS PER HOUR
MINIMUM CIRCUIT AMPACIT(
MECHANICAL
MANUFACTURER
MINIMUM/ MINUTE
MISCELLANEOUS
MILLIMETERS
MEDIUM PRESSURE STEAM
MOUNTED
NITROGEN
NOT APPLICABLE
NORMALLY CLOSED/ NOISE 'CRITERIA
NATURAL GAS
NOT IN CONTRACT
NORMALLY OPEN/ NUMBER
NITROUS OXIDE
NOMINAL
NON -POTABLE
NOT TO SCALE
OXYGEN
ON CENTER
OUTSIDE DIAMETER/DIMENSION/ OVERFLOW DRAIN
OPEN DRIPPROOF
OVERFLOW ROOF DRAIN
OVERHEAD
PRESSURE DROP/ PIT DRAIN/ PUMP DISCHARGE
PERFORATED
PHASE
PLUMBING
POINT OF CONNECTION
PRESSURE
PRESSURE REDUCING VALVE
PRESSURE SWITCH
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH GAUGE
POLYVINYL CHLORIDE
QUANTITY
RISER / RETURN
RECEIVER
ROOF DRAIN/ REFRIGERANT DISCHARGE
RECIRCULATING/ RECIRCULATE
REDUCE/ REDUCING
REFERENCE
REGULATOR
RAIN LEADER/ REFRIGERANT LIQUID
REDUCED PRESSURE BACKFLOW PREVENTER
REVOLUTIONS PER MINUTE
REFRIGERANT SUCTION
RELIEF VALVE
RELIEF VALVE DISCHARGE
SOIL/ SUPPLY
SANITARY
SATURATION
STORM DRAIN
SEATfLE ___ CODE
SECTION
SCREENED OPENING
SOLENOID
SOLENOID VALVE
STATIC PRESSURE/ SPRINKLER
SPECIFICATION
SQUARE
SQUARE FEET
SANITARY SEWER
STRUCTURAL
SUCTION
TO BE DETERMINED
TEMPERATURE DIFFERENTIAL
TEMPERATURE/ TEMPORARY
THERMOMETER
TOP OF PIPE
TRAP PRIMER
TRAP SEAL
TYPICAL
UNDERGROUND
UNLESS NOTED OTHERWISE
UNIFORM PLUMBING CODE
URINAL
UTILITY
VENT/ VOLT
VALVE/ VOLT AMPERE/ VACUUM AIR
VOLTS ALTERNATING CURRENT/ VACUUM
VACUUM BREAKER
VELOCITY/ VERIFY EXACT LOCATION
VERTICAL
VOLUME
VENT RISER
VENT THROUGH ROOF
WASTE/ WIDTH/ WATT
WITH
WITHOUT
WASTE ANESTHESIA GAS DISPOSAL
WATER CLOSET
WALL CLEANOUT
WALL HYDRANT/ WATER HEATER/ WATT HOUR
WELDED
WATER METER
WASTE OIL
WATERPROOF/ WEATHERPROOF
WASTE RISER
WATERTIGHT/ WEIGHT
WORKING WATER PRESSURE
PLUMBING / PIPING LEGEND
o ELBOW UP
ELBOW DN
DIRECTION OF FLOW
DIRECTION OF SLOPE DOWN
REDUCER
TEE OUTLET UP
TEE OUTLET DOWN
II UNION
PIPE ANCHOR
EXPANSION JOINT
STRAINER WITH BLOWDOWN VALVE
GATE VALVE
GLOBE VALVE
' ' BALL VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
FLOW BALANCING VALVE (AUTO OR MANUAL)
T&P RELIEF VALVE
GAS COCK
LINE CLEANOUT
PRESSURE GAUGE WITH GAUGE COCK
THERMOMETER
FLEXIBLE CONNECTION
J PLUG OR CAP
WATER HAMMER ARRESTOR
I�1 BUTTERFLY VALVE
SOLENOID VALVE
BACKFLOW PREVENTER
REDUCED PRESSURE BACKFLOW PREVENTER
D4
Jr n_nr1
1I> 1
IDD1
(METER
T
GRW
SD
OSD
NPCW /NPHW
DI
WAGD
CA
CO2
N2
NO2
02
MA
MV
MPS(#)
MPR(#)
LPS(#)
LPR(#)
COND
O
EWH-1
METER
P&T PORT
EXISTING PIPING
DEMO PIPING
WASTE
VENT
DOMESTIC HOT WATER -RECIRCULATING
DOMESTIC HOT WATER
DOMESTIC COLD WATER
GREASE WASTE
STORM DRAIN
OVERFLOW STORM DRAIN
NON -POTABLE COLD/HOT WATER
DEIONIZED WATER
WASTE ANESTHESIA GAS DISPOSAL
COMPRESSED AIR
CARBON DIOXIDE
NITROGEN
NITROUS OXIDE
OXYGEN
MEDICAL AIR
MEDICAL VACUUM
MEDIUM PRESSURE STEAM SUPPLY
MEDIUM PRESSURE STEAM CONDENSATE RETURN
LOW PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM CONDENSATE RETURN
CONDENSATE
FLOOR CLEANOUT
FLOOR DRAIN / SINK
PUMP
ROOF DRAIN OR OVERFLOW DRAIN
PLUMBING FIXTURES
PLUMBING FIXTURE DESIGNATION
POINT OF CONNECTION
RISER DESIGNATION
PLUMBING EQUIPMENT DESIGNATION
DRAWING (CIRCLE NOTE) REFERENCE
PLUMBING / PIPING GENERAL NOTES
1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS,
INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC, 2015 IMC, & SIMILAR YEAR
WAC 296-104 BOILER RULES.
2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS,
DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION,
TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH
REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS
AS DESCRIBED IN THE CONTRACT DOCUMENTS.
3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED.
4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE
APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL
IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS
AS APPLICABLE.
5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS
REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE
DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN
ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL.
6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY
THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S
INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS.
7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS
SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL
MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS
(FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED
PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE
HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS.
8. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS
SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER.
9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE
MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL
FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR
WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON
ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION.
10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS.
11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER ,TO ARCHITECTURAL
DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE.
12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND
SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT.
13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS.
COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES.
14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY
THE AUTHORITY HAVING JURISDICTION UNLESS NOTED OTHERWISE.
15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR
PRIOR TO EACH CONCRETE POUR.
16. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH
DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS.
17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE
SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED.
PROVIDE 1 " TALL PAN WHERE INSTALLED ABOVE A CEILING.
18. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE
INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION.
19. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED
AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR
EXCEED CODE MINIMUM.
20. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT " PER FOOT UNLESS OTHERWISE NOTED.
21. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409
IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE
NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS.
THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF
COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION
READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED.
22. ARCHITECTURAL ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GC AT ALL CONCEALED
EQUIPMENT AND DEVICE LOCATIONS, UNLESS NOTED OTHERWISE.
MINIMUM
PIPE INSULATION LAST UPDATED: 07/11/16
FLUID DESIGN
OPERATING
TEMP °F
INSULATION CONDUCTIVITY
NOMINAL PIPE DIAMETER (INCH)
CONDUCTIVITY
RANGE
MEAN TEMP
RATING °F
<1
1 TO
<1-1/2
1-1/2 TO
<4
4 TO
<8
>8
HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC)
>350
0.32-0.34
250
4.5
5.0
5.0
5.0
5.0
251-350
0.29-0.32
200
3.0
4.0
4.5
4.5
4.5
201-250
0.27-0.30
150
2.5
2.5
2.5
3.0
3.0
141-200
0.25-0.29
125
1.5
1.5
2.0
2.0
2.0
105-140
0.21-0.28
100
1.0
1.0
1.5
1.5
1.5
DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION)
N/A
0.21-0.27
75
0.5
0.5
0.5
0.5
0.5
COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)**
40-60
0.21-0.27
75
0.5
0.5
1.0
1.0
1.0
_-_ <40
0.20-0.26
75
0.5
1.0
1.0
1.0
1.5
NUII:
* NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA.
** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED AND SEE R403 FOR RESIDENTIAL INSTALLATIONS.
FIL
Permit No.
5[9-F0117
Plan review approval Is subject to errors and
omissions Approval of construction documents does
Tot auth:+rize the violation of any adopted code or
ordinance Receipt of approved Field Copy and
Itlins Is ackno
By
j v
Date:
City of Tukwila
BUILDING DIVISION
DRAWING
INDEX
SHEET NO.
SHEET TITLE
CURRENT
REVISION
P0.00
COVER SHEET - PLUMBING
P2.01
1ST FLOOR PLAN - PLUMBING
P2.02
2ND FLOOR PLAN - PLUMBING
APN NUMBER
102304-9082
LEGAL DESCRIPTION
LOT 5 OF TUKWILA BLA
F
SRE BIJIRED FORT
rt Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
L02-057 REC #20030327900002 LOCATED IN SE 1/4
SEC 9 & 1 n-IN-�3-04
REVI--SIONS
No changes shall be mane to the scope
of work wltnout prior approval of the •
Tukwila Building Division.
NOTE: Revisions will require a new plan
submittal and may include additional plan review.
011111.111,,
Burlen-'
VICINITY MAP
NO SCALE
a�ssan anit
Pha rma.,,
SITE MAP
NO SCALE
FOR CITY USE
KuMmo
Gana Coulon
"Memorial
Pdk
TukK110 Fomily"�
Fun CoNer 8.:
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 2 4 2019
ArJ 0A2.
City of Tukwila
BUILDING DIVISION
RECEIVED
%ATV Or TUKWILt+
JAN 2 2 2019
PERMIT CENTER
Hermanson
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLOO5BJ
SDC 42
SUITE 4203
3355 S 120TH PL
TUKWILA, WA 98168
ONALti
I/2?"/2`-, iL)
Revisions
01/22/19 MLG ISSUE FOR PERMIT
No. Date By Description
Design
Design Team
MLG
Drawn KDE
Checked DTN
Pre Construction Number
Construction Number
Issue Date
10-18-05003
XX-XX-XXXXX
XX/XX/XX
COVER
SHEET
- PLUMBING
ISSUE FOR PERMIT
.,0+,+;
0•�•;
►,'4+ •41
+••+•••
0••++1
►Oi'••i
►0••+4
4440
uomo
:;•••,'••,,.;
o
►,•,• .•.
►,•+•,..
0•••••'i
►AA•1
`al4444
tO\IN ►••,1
iM
YI' ►•••1
►.••++••1
0'4'�•i
►�'•+,'�1
••,,•.
►.•••,•„••+*••.••,••+•+•,•,••,••••••+•••,+,.••..+„•
►00•,O'.❖.❖.•O.'.❖.O'.•.►•'.+.•O.•O.❖.'.•.00••'O•'•••••+.•.+•+O.'••,••OQ•."AN
►•A.•,•+.••'•'A,'.O+A•O•A,•44.0 A.•,••,•A•,•,O•,'O,'••.',•,•••+.'+'•,'.'.+.+,••~0
■I IIIII iliv •• 4`C-.•,-,•4•,•+•,-.•,*+-4•4•* ••.... •'.•••,',•+-,-4•+•..*•+-.•••4•+-,-••+•.•.-.-+•4-.•+•.•.-.','•'.'•1
`rill
RV
-MR
108ios
2"W UP
TO FD
FRONT
2"W UP
TO FD
IV TO EXIST
4"W UP
y'�G 7 PARTIAL 1ST FLOOR PLAN - PLUMBING
4"W
r
4"W
4"W UP
SCALE: 1/8" = 1'—O"
J
u
u
u
1
FE
4"W UP
4"W
EXISTING 4" WASTE
TO TOP OF
7-• 4"W
2"V UP (TYP)
REVIEWED FOR
CODE COMPLIANC
APPROVED
JAN 2 4: 2019
City of Tukwila
BUILDING DIVISION
FOR CITY USE
RECEIVED
CITY OF TUKWILA
JAN 2 2 2019
PERMIT CENTER
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLOO5BJ
SDC 42
SUITE 4203
3355 S 120TH PL
TUKWILA, WA 98168
9- /2o11'
Revisions
01/22/19 MLG ISSUE FOR PERMIT
No. Date By Description
Design
Drawn
Design Team
MLG
KDE
Checked DTN
Pre Construction Number
Construction Number
Issue Date
10-18-05003
XX—XX—XXXXX
xX/xx/xx
1ST FLOOR
PLAN
- PLUMBING
ISSUE FOR PERMIT
i—i
4"
L
AHU-4B
7
7
7
1,7
AHU-4A
2"V (TYP)
2"CW
mI( FD—T)
N
Il
AHU-3B
L-
-7\— 3' V
4,,
PARTIAL 2ND FLOOR PLAN - PLUMBING
9
AHU-3A
2"CW
11
4"
El
2"ICW UP
AHU-2B
(HB-D
7
7
7
14.7
AHU-2A
11
2"CW
2"CW
AHU-1B
TRAP SEAL PRIMERS
No form of trap that depends for its seal upon the action of
movable parts shall be used. Each fixture trap shall have a
liquid seal...and shall be protected from freezing.
Floor drain or similar traps directly connected to the drainage
system and subject to infrequent use shall be protected with a
trap seal primer. Trap seal primers shall be directly connected
to the water supply and shall be accessible for maintenance.
(2015 UPC 1005.0, 1006.0 & 1007.0)
SCALE: 1/8" = 1'-0"
N
I-----�
AHU-1A
11
1 i"CW
FOR CITY USE
RE IEVVtu
COD COMPL
.APPROVED
.;Ail 2 42819
City of Tukwila
BUILDING DIVISION
1
RECEIVED
PITY OF 7.
UI(WIL,
JAN 2 2 2019
PERMIT CENTER
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACL005BJ
SDC 42
SUITE 4203
3355 S 120TH PL
TUKWILA, WA 98168
y ,22/2o 10)
Revisions
01/22/19 MLG ISSUE FOR PERMIT
No. Date By Description
Design
Design Team
MLG
Drawn
KDE
Checked DTN
Pre Construction Number
Construction Number
Issue Date
10-18-05003
XX—XX—XXXXX
XX/XX/XX
2ND FLOOR
PLAN
- PLUMBING
ISSUE FOR PERMIT