Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG19-0015 - WESTFIELD SOUTHCENTER MALL - RESTROOM UPGRADE
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. PG19-0015 WESTFIELD – RESTROOM UPGRADE 2800 SOUTHCENTER MALL DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page #Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers individuals’ privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW DR1 Generally – 5 U.S.C. sec. under section 42.56.070(1) of the Washington 42.56.070(1) 552(a); RCW State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW account numbers, which are exempt from 19 DR2 Financial Information – 42.56.230(5) disclosure pursuant to RCW 42.56.230(5), RCW 42.56.230(4 5) except when disclosure is expressly required by or governed by other law. Personal Information – Redactions contain information used to prove RCW Driver’s License. – RCW identity, age, residential address, social security 42.56.230 (7a DR3 number or other personal information required to 42.56.230 & c) apply for a driver’s license or identicard. (7a & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney-Client Privilege – disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); RCW 5.60.060(2)(a); RCW which protects attorney-client privileged DR4 RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. WESTFIELD RESTROOM UPGRADE 2800 SOUTHCENTER MALL PGI 9-0015 Parcel No: Address: City of Txnk"°x^U Department -, Community Development 63008outh*mnterBoulevard, Suite #100 Tukwila, Washington 98100 Phone: 206-431-3670 Inspection Request Line: 206-438'9350 Web site: h#p:/Ymmvw.TukmUaVVA.mnv 9202470010 PLUMBING/GAS PIPING PERMIT Project Name: VV[STF[LDRESTROOMUPGRADE Permit Number: PG19-0015 Issue Date: 2/14/I019 Permit Expires On: 8/13V2019 Owner: Name: Contact Person: Name: Name: Address: License No: VV[STF|ELDPROPERTY TAX DEPT POBOX 1]O940'[ARLS8AD,WA, 92013 PAUL[NGERT Z899U5EZ2NDWAY, 54MMAN1|SH' PLUMBING EXPRESS INC POBOX 222G,5UN1NER,WA, 98390 PLVxxOB98600 ''' Phone: (253) 826-4621 Expiration Date: 9/20/2019 , DESCRIPTION &FWORK: REMODEL PLUMBING PUBLIC RESTROOMS 12 TOILETS, 5 URINALS AND 10 SINKSValuation ofWork: $72,500.00 Water District: 0KWILA Sewer District: TUKWILA Fees Collected: $680.21 Current Codes adopted bVthe City mfTukwila: international Building Code Edition: international Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: international Fuel Gas Code: rized Signature: ational Electrical Code: VVACities Electrical Code: VVACZg646O: VVAState Energy Code: 2017 20172017 2015 Date: |hearby certify that | have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting nfthis permit does not presume tpgive authority toviolate urcancel the provisions ofany other state orlocal laws regulating construction orthe performance oywork. |amauthorized mosign and obtain this development permit and agree tothe conditions attached tothis permit. Print Na This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, nrif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS' 1: ^*~PLVyWB|mG/GAS PIPING PERMIT COmDITIONS~~~ 2: No changes shall bemade toapplicable plans and specifications unless prior approval isobtained from the Tukwila Building Division. ]: AUpermits, inspection records and applicable plans shall bemaintained at the job and available tothe plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. j: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall beconducted inthe presence nfthe Plumbing Inspector. itshall bethe duty of the holder ofthe permit to make sure that the work will stand the test prescribed before giving notification that the work bready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision ismade toprotect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall beinsulated tominimum R'3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall beprotected bysteel nail plates not less than 18gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall bedirectly embedded inconcrete urmasonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall beprotected inaccordance with the requirements ofthe building code. 11: Piping inthe ground shall belaid onafirm bed for its entire length. Trenches shall beback0Uedinthin layers motwelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, dnderOU'frozen earth, orconstruction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance ofthe jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Effkiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 4VZofWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: '‘‘‘vw.TolmilaWA.goN Plumbing/Gas Permit No. Project No. Date Application Accepted: 13- 1 9 Date Application Expires: (For office use only) PLUMBING GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** 3 0441(01 iev Site Address: 2tco bwagrf=5 1VVp1L Suite Number: Floor: Tenant Name: Levet.. cm. 1:13a532oavi OpA2,4m New Tenant: Yes J ..No PROPERTY OWNER Name: cow.. 12cDAtisco cqap Address: 28Icp vie5rilap writ City. State: vi Zip:cf we CONTACT PERSON — person receiving all project communication Name: -pm, E49. tool Address: 244F(D sE 22,ND City: spspitmm40 State: Alk Zipt500/5 Phone: 2.„, 725. : arCh9 rearii Email 0 • King Co Assessor's Tax No.: 9 2.02.41 0 PLUMBING CONTRACTOR INFORMATION Company Name: PLUMBING EXPRESS INC Address: PO BOX 2226 City: SUMNER State: WA Zip: 98390 Phone: (253) 255-1828 Fax: (253) 904-8386 Contr Reg No.: pLumBE98600 Exp Date: 09/20/2020 Tukwila Business License No.: BUS-0997429 Valuation of Project (contractor's bid price): $ 72,500 Scope of Work (please provide detailed information): REMODEL PLUMBING PUBLIC RESTROOMS 12-TOILETS, 5 URINALS,10 SINKS Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water C-trf Sewer: Cfre 11* - HAApplieetiduSkFutod-Applusttions On Ime201 ApplicatiotoWlumbirtg Peruse Applozetion Revised 8-4-I I slims RevisedAugust ZO I 1 hit Paw I of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below Fixture Type Q1' Bathtub or combination bath/shower Dishsvasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type .' Bidet Drinking fountain or water cooler (per head) Lavatory 10 Urinal 5 Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type QtY Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 12 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qtv Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter : including backflow '... protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of appEcation shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OVeNr R 0 AUDI ZED GENT: Signature: 121.dt Date: 1 • Print Name: Mailing Address: Day Telephone: City Elkt‘AM/A—NAW 20 7.25 - 443 State Zip m4- 003073 WApplicatiewOurns-Applications On Linc12011 AppbealioeMPItenbing Perme Appbcation Revised 6-9-1 idecv Revsed: Augum 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $680.23. PG19-0015 Address: 2800 SOUTHCENTER MALL Apn: 9202470010 $680.21 Credit Card Fee $19.81 Credit Card Fee R000.369.908.00.00 0.00 $19.81 PLUMBING $635.00 PERMIT FEE R000.322,100.00.00 0,00 $473,00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $127.00 TECHNOLOGY FEE $25.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16606 R000,322,900,04.00 0.00 $25.40 $680.21 Date Paid: Wednesday, January 23, 2019 Paid By: PAUL ENGERT Pay Method: CREDIT CARD 023817 Printed: Wednesday, January 23, 2019 2:51 PM 1 of 1 MS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 01/23/2019 02:50:44 PM CREDIT CARD SALE VISA CARD NUMBER: **********3073 K TRAN AMOUNT: $680.21 APPROVAL CD: 023817 RECORD #: 000 CLERK ID: jazzel {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWILA ETRAKIT 6280 SOUT*[ENTEK BLVD TUKWILA' WA 98188 20*-433-1870 CITY OF TUKWILA Date: 01/23/2019 02:50:44 PM CnsozT C4no SALE VISA CARD NUMBER: **********]87] K TRAN AMOUNT: $680.21 APPROVAL [D: 023817 RECORD #: 008 [Lsxx ID: jazzel Thank you! Customer Copy INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6'U0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Projec ; Type joffylnspection: Address: Date Called: Date SpecialInstructions: Wanted: - 4' 4 ,,11 Requester Phone No: Zr3 4OC Sy2 Approved per applicable codes. MENTS: Corrections required prior to approval. i Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. Type o pec ion: ections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of pection: PLAIAISi .1, .., Address: Date Called: Special in _ uctions; Date Wanted: . .' Requester: Phone No: 24 riApproved per applicable codes. 0 ENTS: Corrections required prior to approval. ns pector. e: ri REINSPECT FEE REQUIRED. Prior to next inspection. fee mu'st be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. METRIX ENGINEERS January 30, 2019 Paul Engert Engert Architecture 26990 SE 22"d Way Sammamish, WA 98075 Dear Paul: METRIXENG.COM RECEIVED COTY OF TUKWILA JAN 31 2019 PERMIT CENTER The purpose of this narrative is to address and respond to the January 28, 2019, comments generated during the City of Tukwila's BUILDING — PG DEPARTMENT review of the Westfield Southcenter Level One Restroom Upgrade project at 2800 Southcenter Mall under Permit Application Number PG19-0015. Each of the comments and responses are indicated below: BUILDING REVIEW NOTES 1. Comment: Plans do not show floor -drains on DWV or the trap primer connections on water supply drawings. Provide plans showing floor drains and trap primers on floor plan and isometric drawings. Response: The following plans have been updated to indicate the existing floor drains to remain and new trap primers with connections to be made: • Sheet MD1.0 — UNDERGROUND DEMOLITION PLAN — Revised Flag Note #5 to indicate that existing underground trap primer piping is to remain for future connection. • Sheet MD1.1 — FIRST FLOOR DEMOLIITION PLAN — Added Flag Note #10 to indicate that existing floor drains and trap primer piping are to remain for future connection. • Sheet M1.0 — UNDERGROUND PLAN — Revised notes indicating floor drains to explicitly state they are existing floor drains. • Sheet M1.1 — FIRST FLOOR PLAN — Added Flag Note #9 indicating new trap primer and connection to existing trap primer piping.' Added Flag Note #10 indicating the re -use of the floor drain and connection to the existing trap primer piping. • Sheet M3.1 WASTE VENT RISERS — Added new trap primer and connection to existing trap primer piping on waste vent risers. Should you have any additional questions or concerns, please feel free to call me at 206-920-9240. CORRECTION LTR# Scott A. Miller, PE Principal PG161 DO 1 5 725 Powell Ave SW, Suite 100 Renton, WA 98057 Office: 425 336 2822 Fax: 425 336 2802 \ City of Tukwila Department of Community Development January 28, 2019 PAUL ENGERT 26990 SE 22ND WAY SAMMAMISH, WA 98075 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG 19-0015 LEVEL ONE RESTROOM UPGRADE - 2800 SOUTHCENTER MALL Dear PAUL ENGERT, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMII'l ALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Plans do not show floor -drains on DWV or the trap primer connections on water supply drawings. Provide plans showing floor drains and trap primers on floor plan and isometric drawings. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 AM! COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0015 DATE: 01/31/19 PROJECT NAME: WESTFIELD RESTROOM UPGRADE SITE ADDRESS: 2800 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ki WC' fliVI°1 Building Division Public Works Fire Prevention Structural n r Planning Division Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 02/05/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 03/05/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg E] Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 ( PEW. COOS COPY PLAN REVIEW/ROUTING SLIP c PERMIT NUMBER: PG19-0015 DATE: 1/23/19 PROJECT NAME: LEVEL ONE RESTROOM UPGRADE SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: e\ Building Division .)J ND( Public Works Fire Prevention Structural Planning Division Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 1/22/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 2/19/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Idg Fire D Ping PW Staff Initials: 0-4 12/18/2013 r- Date: 1/31/2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: PG19-0015 LI Response to Incomplete Letter # • Response to Correction Letter # 1 • Revision # after Permit is Issued El Revision requested by a City Building Inspector or Plans Examiner IJ Deferred Submittal # Project Name: Level One Restroom Upgrade Project Address: 2800 Southcenter Mall Contact Person: Paul Engert Summary of Revision: Response to (1) item in plan review letter Phone Number: 206 225-1443 RECEI CITY OF TUKWILA PERMIT CENTER Sheet Number(s): All Sheets "Cloud" or highlight all areas of revision including revisio Received at the City of Tukwila Permit Center by: e—Entered in TRAKiT on WAPermit CentenTemplaiesTorms \Revision Submittal Form due Revised: August 2015 II,)ItC 1.Spilii01 COntaCt Safety & Health Claims & Insurance Washington State Department of Laor & industries ,Search L6. I k A-Z I ilex I It.'11) Workplace Rights Trades & Licensing PLUMBING EXPRESS INC Owner or tradesperson Principals KILDARE, JOHN THOMAS, PRESIDENT KILDARE, KRISTI KYLE, VICE PRESIDENT Doing business as PLUMBING EXPRESS INC WA UBI No. 602 226 682 PO BOX 2226 SUMNER, WA 98390 253-826-4621 PIERCE County Business type Corporation Governing persons JOHN THOMAS KILDARE KRISTI KYLE KILDARE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active, Meets current requirements. License specialties PLUMBING License no. PLUMBEI98600 Effective — expiration 09/2012002— 09/20/2020 Bond No bond accounts during the previous 6 year period. Insurance American Fire & Casualty Co $1,000,000.00 Policy no. BKA54313254 Received by L&I Effective date 01/04/2019 01/01/2019 Expiration date 01/01/2020 Insurance history Savings (in lieu of bond) $6,000.00 Received by L&I Effective date 11/01/2013 11/01/2013 Release date Impaired date N/A N/A Savings account ID 1 5 us improve / Savings history Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .......... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. PPEJP00927 Issue date 01/10/2018 Violation city SUMNER Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Mr. Jody W. Kildare Infraction no. PZETD00767 Issue date 09/15/2014 Violation city SUMNER Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Plumbing Express employed Jody William Kildare plumber trainee to install ABS waste pipe, installing drain pipe when expired, expired on 5/3/2014 Satisfied RCW/WAC 18.106.020 Violation amount $250.00 .Satisfied ............... RCW/WAC 18.106.020 Violation amount $500.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 890.729-01 Doing business as PLUMBING EXPRESS INC Account is current. Estimated workers reported Quarter 4 of Year 2018 "1 to 3 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Track this contractor Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid Help us improve No debarments have been issued against thit Atractor. Workplace safety and health No inspections during the previous 6 year period. <A' Washington State Dept of Labor & Industries, Use at this site is subject to the laws of the state of Vvtashington, Help us improve ABBREVIATIONS: 0 DIAMETER, PHASE ABV ABOVE AC AIR CONDITIONING UNIT AD AREA DRAIN, ACCESS DOOR ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISHED FLOOR AFUE ANNUAL FUEL UTILIZATION EFFICIENCY AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM AMB AMBIENT APD AIR PRESSURE DROP APPROX APPROXIMATE ARCH ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR-CONDITIONING ENGINEERS, INC. ATM ATMOSPHERE ASHRAE BDD BF BFF BHP BLDG BLW BOD BOP BOT BTU BTUH C CAP CC CD CFH CFM CI CL CLG CMU CO COMB COND CONN CONT BACKDRAFT DAMPER BELOW FLOOR BELOW FINISHED FLOOR BRAKE HORSEPOWER BUILDING BELOW BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR CONDENSATE DRAIN PIPING CAPACITY COOLING COIL CEILING DIFFUSER CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CAST IRON CENTER LINE CEILING CONCRETE MASONRY UNIT CLEANOUT COMBUSTION, COMBINATION CONDENSATE CONNECTION CONTINUE, CONTROL CONTR CONTRACTOR COP COEFFICIENT OF PERFORMANCE CP CONDENSATE PUMP CT CU CV CW DB DC DDC DEPT DEG DF DH DI DIA DIAG DIFF DIM DN DP DX DWG (E) EA EAT ECG EDH EER EF EFF EG EJ ELEC ELEV EMCS ENT EQUIP ESP ET ETC EUH EVAP EW EWC EWH EWT EX EXT COOLING TOWER CONDENSING UNIT, CUBIC CHECK VALVE, CONSTANT VOLUME DOMESTIC COLD WATER DRY BULB DUCT COIL, DUST COLLECTOR DIRECT DIGITAL CONTROL DEPARTMENT DEGREE DRINKING FOUNTAIN DUCT HEATER DUCTILE IRON DIAMETER DIAGRAM DIFFERENTIAL DIMENSION DOWN DIFFERENTIAL PRESSURE DIRECT EXPANSION DRAWING EXISTING EACH, EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE ELECTRIC DUCT HEATER ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY EXHAUST GRILLE EXPANSION JOINT ELECTRIC ELEVATION ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE EXPANSION TANK AND SO FORTH ELECTRIC UNIT HEATER EVAPORATOR, EVAPORATIVE EYE WASH ELECTRIC WATER COOLER ELECTRIC WATER HEATER ENTERING WATER TEMPERATURE EXHAUST EXTERIOR, EXTERNAL F 'F FC FCU FD F/D FDC FFD FLA FLR FLEX FP FPM FPS FS F/S/D FT FV G GAL GALV GC GFU GPD GPH GPM GPR GR GRD GWB HB HC HD HOR HP HR HRU HT HTR HX HVAC HZ IAQ IN INCL INT INV ISP FIRE SPRINKLER DEGREES FAHRENHEIT FLEXIBLE CONNECTOR, FLUID COOLER FAN COIL UNIT FLOOR DRAIN FIRE DAMPER FIRE DEPARTMENT CONNECTION FUNNEL FLOOR DRAIN FULL LOAD AMPS FLOOR FLEXIBLE FIRE PROTECTION, FIRE PUMP FEET PER MINUTE FEET PER SECOND FLOOR SINK COMBINATION FIRE SMOKE DAMPER FEET, FINNED TUBE FACE VELOCITY GAS GALLON GALVANIZED GENERAL CONTRACTOR GAS FIRED UNIT GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE GAS PRESSURE REGULATOR GRILLE GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HOSE BIBB HEATING COIL HEAD HORIZONTAL HEAT PUMP, HORSEPOWER HOUR HEAT RECOVERY UNIT HEIGHT HEATER HEAT EXCHANGER HEATING, VENTILATION & AIR CONDITIONING HERTZ INDOOR AIR QUALITY INCH INCLUDING INTERNAL INVERT INTERNAL STATIC PRESSURE KW KILOWATT L LAT LAV LB LBS/HR LD LF LL LRA LVG LVR LWT MAT MAV MAX MBH MCA MECH MED MERV MFR MIN MISC MOCP MPC MPG MPS MS MTD MU MUA (N) NA NC NEG NO NO. NOM NTS 02 OA OAT OBD OC OCC OSA OT OV LENGTH LEAVING AIR TEMPERATURE LAVATORY POUND POUNDS PER HOUR LINEAR DIFFUSER LINEAR FEET REFRIGERANT LIQUID LINE LOCKED ROTOR AMPS LEAVING LOUVER LEAVING WATER TEMPERATURE MIXED AIR TEMPERATURE MANUAL AIR VENT MAXIMUM THOUSANDS OF BTUH MINIMUM CIRCUIT AMPACITY MECHANICAL MEDIUM MINIMUM EFFICIENCY REPORTING VALUE MANUFACTURER MINIMUM MISCELLANEOUS MAXIMUM OVERCURRENT PROTECTION MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE GAS MEDIUM PRESSURE STEAM MOP SINK MOUNTED MAKEUP WATER MAKEUP AIR UNIT NEW NOT APPLICABLE NOISE CRITERIA, NORMALLY CLOSED NEGATIVE NORMALLY OPEN NUMBER NOMINAL NOT TO SCALE OXYGEN OUTSIDE AIR OUTSIDE AIR TEMPERATURE OPPOSED BLADE DAMPER ON CENTER OCCUPIED OUTSIDE AIR OFF TOP OUTLET VELOCITY P PC PD PERF PH PIV POC PRESS PRV PSI PSIG PSIA PTRV PU PVC PRESSURE, PUMP PUMPED CONDENSATE PRESSURE DROP PERFORATED PHASE POST INDICATOR VALVE POINT OF CONNECTION PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE POUNDS PER SQUARE INCH ABSOLUTE PRESSURE/TEMPERATURE RELIEF VALVE PUMP POLYVINYL CHLORIDE QTY QUANTITY R RA RAF RAG RAH RCP RD REF REG REL REQD RET RF RG RH RHC RLA RM RPM RTU RV SA SAD SAT SCFM SCH SCHEM S/D SF SG SL SMACNA SP SPEC SQ SRV SS ST STD STM STR SUCT SUP TAB TDH TEMP TG TOD TOF TOP TP TPRV TSP T'STAT TU TYP REFRIGERANT PIPING RETURN AIR RETURN/RELIEF AIR FAN RETURN AIR GRILLE RADIANT HEATER REFLECTED CEILING PLAN ROOF DRAIN REFERENCE, RETURN/EXHAUST FAN REGISTER RELIEF REQUIRED RETURN RETURN FAN RETURN GRILLE RELATIVE HUMIDITY, ROOF HOOD REHEAT COIL RATED LOAD AMPS ROOM REVOLUTIONS PER MINUTE ROOFTOP UNIT RELIEF VALVE SUPPLY AIR SUPPLY AIR DIFFUSER SUPPLY AIR TEMPERATURE STANDARD CUBIC FEET PER MINUTE SCHEDULE SCHEMATIC SMOKE DAMPER SUPPLY FAN, SQUARE FOOT SUPPLY GRILLE REFRIGERANT SUCTION LINE SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, INC. STATIC PRESSURE SPECIFICATION SQUARE SAFETY RELIEF VALVE STAINLESS STEEL STORAGE TANK, SOUND TRAP STANDARD STEAM STARTER, STRUCTURAL SUCTION SUPPLY TESTING, ADJUSTING AND BALANCING TOTAL DYNAMIC HEAD TEMPERATURE TRANSFER GRILLE TOP OF DUCT TOP OF FOOTING TOP OF PIPE TOTAL PRESSURE TEMPERATURE/PRESSURE RELIEF VALVE TOTAL STATIC PRESSURE THERMOSTAT TERMINAL UNIT TYPICAL UH UNIT HEATER UNOCC UNOCCUPIED V VAV VD VEL VENT VFD VTR W W/ WB W/0 WPD WSEC WSFU WT WTD VENT, VOLTS VARIABLE AIR VOLUME UNIT VOLUME DAMPER VELOCITY VENTILATION, VENTILATOR VARIABLE FREQUENCY DRIVE VENT THRU ROOF WASTE, WATT, WIDTH WITH WET BULB WITHOUT WATER PRESSURE DROP WASHINGTON STATE ENERGY CODE WATER SUPPLY FIXTURE UNIT WEIGHT WATER TEMPERATURE DROP REFERENCE SYMBOLS ///////// 1 MX.X AHU-XXX 1 J NEW MECHANICAL WORK EXISTING MECHANICAL WORK EXISTING MECHANICAL WORK TO BE DEMOLISHED ENLARGED PLAN BORDER MATCHLINE SECTION IDENTIFIER DETAIL OR DRAWING IDENTIFIER REVISION CLOUD INDICATES WHERE SECTION APPEARS INDICATES REVISION & NUMBER FLAG NOTE EQUIPMENT IDENTIFIER POINT OF CONNECTION NORTH ARROW MECHANICAL ACCESS PLUMBING LINE DESIGNATION SYMBOLS OEM IMP DOMESTIC COLD WATER (POTABLE) DOMESTIC HOT WATER (POTABLE ) DOMESTIC HOT WATER CIRCULATING (POTABLE) SANITARY SEVVER ABOVEGROUND SANITARY SEWER UNDERGROUND VENT PIPING PIPING ELEMENTS/VALVING N i' VALVE CHECK VALVE BALANCING VALVE PRESSURE REDUCING VALVE (PRV) DIRECTION OF FLOW UNION BACKFLOW PREVENTION DEVICE (REDUCED ZONE) BACKFLOW PREVENTION DEVICE (DOUBLE CHECK VALVE ASSEMBLY) WATER HAMMER ARRESTER HOSE BIBB FLOOR DRAIN FCO CLEAN -OUT (FLOOR) WCO CLEAN -OUT (WALL) C0 CLEAN -OUT PIPE CONTINUES PIPE CAP PIPE RISING UP PIPE DROPPING DOWN PIPE CONNECTION 0 PIPE CONNECTION DOWN DUCTWORK SYMBOLS } BDD v P NEW DUCTWORK RISE OR DROP DIRECTION OF AIR FLOW INTERNALLY LINED DUCT MANUAL VOLUME DAMPER BACKDRAFT DAMPER RECTANGULAR DUCT UP RECTANGULAR DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN FLEXIBLE DUCTWORK DIFFUSER, REGISTER, AND GRILLE SYMBOLS X CFM CONTROLS 0 OS AIR DEVICE TAG SUPPLY DIFFUSER RETURN OR RELIEF GRILLE EXHAUST GRILLE ROOM THERMOSTAT OCCUPANCY SENSOR CONTROL WIRING SEPARATE PERMIT RE UIRED FOR: Mechanical Electrical ❑ Plumbing Eiril Gas Piping City of Tukwila BUILDING DIVISION FILE Permit No. RA ONO Plan review approval is subject to errors and omissions Approval of construction documents does lot autr , •ize the violation of any adopted code or ordinance Rfceipt of approved Pieta Copy and ftditlOrlswle By Date . s-/4"_`c7 City of Tuihnnia ai IiLf)INC; :)IVISION REVISIONS No changes shall be mace to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new clan submittal and may include additional plan review. MECHANICAL SHEET INDEX MO.1 MECHANICAL AND PLUMBING LEGEND AND GENERAL NOTES MO.2 MECHANICAL AND PLUMBING SCHEDULES MD1.0 UNDERGROUND PLAN - DEMOLITION MD.1.1 FIRST FLOOR PLAN - DEMOLITION M1.0 UNDERGROUND PLAN M1.1 FIRST FLOOR PLAN M2.1 DETAILS M3.1 WASTE/VENT RISER DIAGRAM GENERAL NOTES: GENERAL: 1. COORDINATE MECHANICAL WORK WITH ELECTRICAL, ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE WORK SHOWN ON OTHER CONTRACT DOCUMENTS. PROVIDE ADDITIONAL OFFSETS FOR COORDINATED INSTALLATION WHERE REQUIRED. 2. COORDINATE HVAC, PLUMBING AND FIRE PROTECTION WORK PRIOR TO INSTALLATION. DUCTWORK AND EQUIPMENT ACCESS TAKES PRECEDENCE OVER PIPING FOR AVAILABLE SPACE. 3. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". 4. COORDINATE EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE DUCT AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE DUCT AND PIPING DIMENSIONS BEFORE FABRICATION. 5. PROVIDE MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION OF MECHANICAL SYSTEMS. 6. LOCATE VALVES, WATER HAMMER ARRESTERS, CLEANOUTS, DAMPERS, CONTROLS AND SIMILAR COMPONENTS SO THAT THEY ARE ACCESSIBLE. PROVIDE ACCESS DOORS FOR MECHANICAL EQUIPMENT INSTALLED BEHIND WALLS, ABOVE INACCESSIBLE CEILINGS AND BELOW FLOORS. COORDINATE ACCESS DOOR LOCATIONS WITH ARCHITECT/ENGINEER. INSTALL TAG ON CEILING GRID FRAME TO INDICATE LOCATION AND TYPE OF EQUIPMENT THAT REQUIRES MAINTENANCE. PROVIDE 16 GA, STEEL, FLUSH TYPE ACCESS DOOR WITH CONCEALED HINGE AND SLOT SCREWDRIVER TYPE CAM LATCH. PROVIDE FACTORY PRIMED IN PAINTED SURFACE AREAS FOR FIELD PAINTING. PROVIDE STAINLESS STEEL FOR ALL OTHER AREAS. PROVIDE UL LISTED AND LABELED DOOR WHERE FIRE -RESISTANCE RATING IS INDICATED ON DRAWINGS. ACCESS DOOR SHALL BE SIZED SO THAT ADJACENT EQUIPMENT IS ACCESSIBLE. PROVIDE ACUDOR, ELMDOR, MILCOR, OR APPROVED. 7. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER LOADS IMPOSED. 8. REFER TO TYPICAL DETAILS PROVIDED IN THIS DWG SET FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE WITH DETAILS. 9. LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH OTHER TRADES INVOLVED. INCLUDE IN THE COST OF MECHANICAL WORK, CUTTING, CORING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS, FLOORS AND ROOFS AS REQUIRED TO ACCOMMODATE WORK AS INDICATED IN THE MECHANICAL CONTRACT DOCUMENTS, UNLESS SPECIFICALLY SHOWN ON ARCHITECTURAL DRAWINGS. 10. PROVIDE ELASTOMERIC FOAM MATERIAL ON MECHANICAL EQUIPMENT THAT PRESENT A SAFETY HAZARD. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS. 12. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSE BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT. BEFORE SUBSTANTIAL COMPLETION, CLEAN EQUIPMENT, FIXTURES, EXPOSED DUCTS, PIPING AND SIMILAR ITEMS. 13. PROVIDE EQUIPMENT THAT FITS INTO THE SPACE ALLOTTED AND ALLOWS ADEQUATE ACCEPTABLE CLEARANCE FOR INSTALLATION, REPLACEMENT, ENTRY, SERVICING AND MAINTENANCE. COORDINATE WITH OTHER TRADES TO ENSURE NO CONFLICT WITH REQUIRED CLEARANCES. 14. PROVIDE OFFSETS IN PIPING WHERE PLUMBING/PIPING WALL IS LOCATED DIRECTLY ABOVE STRUCTURE. OFFSET PIPING INTO CASEWORK OR SHAFT TIGHT TO WALL AND BACK INTO WALL ONCE BELOW STRUCTURE. REFER TO STRUCTURAL DRAWINGS. 15. BUILDING SPACE IS LIMITED. STRONG ATTENTION TO DETAIL AND CARE MUST BE TAKEN WHEN DEVELOPING SHOP DRAWING SO ROUTING IS COORDINATED WITH OTHER DISCIPLINES. 16. MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. 17. MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL PANELS, MOTOR STARTER, MOTOR CONTROLLERS, VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT SHALL CARRY A SHORT CIRCUIT CURRENT RATING (SCCR) EQUAL TO OR GREATER THAN AVAILABLE FAULT CURRENT DELIVERED FROM ELECTRICAL SYSTEM. INCLUDE VISIBLE FACTORY NAMEPLATE FOR SUCH EQUIPMENT INDICATING SCCR OF EQUIPMENT IN ACCORDANCE WITH UL 1995 AND UL 508A. PIPING: 1. PROVIDE AN AUTOMATIC AIR VENT AT THE HIGH POINT OF EACH DROP IN THE HEATING WATER, CHILLED WATER, AND OTHER CLOSED WATER PIPING SYSTEMS. PIPE VENT TO NEAREST DRAIN. PIPING SHALL GRADE TO LOW POINTS. PROVIDE HOSE END DRAIN VALVES AT THE BOTTOM OF RISERS AND LOW POINTS. 2. VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN SERVICE WHEN EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF VALVE IS REMOVED. 3. VALVES (EXCEPT CONTROL VALVES) AND STRAINERS SHALL BE FULL SIZE OF PIPE BEFORE REDUCING SIZE TO MAKE CONNECTIONS TO EQUIPMENT AND CONTROLS. 4. PROVIDE UNIONS AND/OR FLANGES AT EACH PIECE OF EQUIPMENT, AT EACH CONTROL VALVE, IN BYPASSES, AND IN LONG PIPING RUNS (100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR ALTERATION AND REPAIRS. 5. PROVIDE FLEXIBLE CONNECTORS IN PIPING SYSTEMS CONNECTED TO AIR HANDLING EQUIPMENT, PUMPS, CHILLERS, COOLING TOWERS, AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION. 6. PROVIDE LINE SIZE STRAINER UPSTREAM OF EACH BACKFLOW PREVENTER, WATER PRESSURE REDUCING VALVE, AUTOMATIC FLOW CONTROL VALVE, CONTROL VALVE, SOLENOID VALVE, GAS PRESSURE REGULATOR, AND PUMP. PROVIDE SHUTOFF VALVE ON EACH SIDE OF STRAINER. 7. VALVES, EXPANSION, FITTINGS/LOOPS, AND PIPING SPECIALTIES SHALL BE FULL SIZE OF PIPE UNLESS NOTED OTHERWISE. HVAC/SHEET METAL: 1. DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE INCREASED TO COMPENSATE FOR DUCT LINING THICKNESS. 2. PROVIDE TEMPORARY COVERS OVER OPEN ENDS OF EQUIPMENT AND DUCTWORK DURING CONSTRUCTION. 3. PROVIDE MANUAL VOLUME DAMPER FOR EACH DIFFUSER, REGISTER, AND GRILLE. 4. PROVIDE DUCT ACCESS DOORS AT DUCT SMOKE DETECTORS, BACKDRAFT DAMPERS, MOTORIZED CONTROL DAMPERS, FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS, DUCT MOUNTED COILS, DUCT AIRFLOW STATIONS AND LOUVER PLENUMS. 5. PROVIDE THE FOLLOWING MINIMUM BRANCH DUCT SIZE TO DIFFUSERS, REGISTERS, AND GRILLES, UNLESS NOTED TO USE LARGER SIZE ON DRAWINGS: 5.1. 6"0: 100 CFM 5.2. 8"0": 200 CFM 5.3. 10"0: 300 CFM 5.4. 12"0: 450 CFM 5.5. 14"0: 600 CFM 5.6. 16"0: 750 CFM FIRE PROTECTION: 1. PAINT ALL EXPOSED AND VISIBLE FIRE SPRINKLER PIPING BLACK. DO NOT PAINT FIRE SPRINKLER HEADS. ENERGY CODE: (STATE ENERGY CODE) 1. MOTORS: COMPLY WITH MINIMUM FULL LOAD EFFICIENCIES LISTED IN THE STATE ENERGY CODE. 2. PIPING AND DUCT INSULATION: COMPLY WITH THICKNESS AND TYPES LISTED IN THE STATE ENERGY CODE. 3. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND LONGITUDINAL SEAMS PER THE STATE ENERGY CODE. 4. RECORD DRAWINGS: PROVIDE PER THE STATE ENERGY CODE. 5. OPERATION AND MAINTENANCE MANUALS: PROVIDE PER THE STATE ENERGY CODE. 6. SYSTEM BALANCING: PROVIDE PER THE STATE ENERGY CODE. 7. MECHANICAL SYSTEMS COMMISSIONING: PROVIDE PER THE STATE ENERGY CODE. 8. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN DESIGNED TO COMPLY WITH THE STATE ENERGY CODE. CONTRACTOR IS RESPONSIBLE FOR CORRECT INSTALLATION OF ENERGY CONSERVATION MEASURES. 9. BUILDING PRESSURE TESTING: COORDINATE PHASING OF BUILDING ENVELOPE LEAKAGE TESTING WITH MECHANICAL SYSTEM SCOPES OF WORK. TEMPORARILY CAP SYSTEMS AS REQUIRED TO FACILITATE LEAKAGE TESTING SCOPE OF WORK. NON-STRUCTURAL MECHANICAL COMPONENTS: 1. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE 2012 INTERNATIONAL BUILDING CODE AND FROM THE AMERIC,BN SOCIETY OF CIVIL ENGINEERS (ASCE) STANDARD 7-10. 1HE REVIEWED FOR CONTRACTOR SHALL REFER TO THE ABOVE FOR ADDITIONAL.iiuDE COMPLIANCE INFORMATION, EXCEPTIONS, AND FURTHER DESCRIPTIC'N THE CONTRACTOR SHALL ADHERE TO REQUIREMENTS 1 ND APPROVED AS SUCH, SHALL BE INCLUDED WITHIN BID. 2. 2012 IBC 1613.1 SCOPE: ARCHITECTURAL, MECHANICAL, FEB 07 2019 ELECTRICAL, AND NON-STRUCTURAL COMPONENTS THPT,V ARE PERMANENTLY ATTACHED TO STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED AN 3 City of Tukwila CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUA (FBUILDING DIVISION MOTIONS IN ACCORDANCE WITH ASCE 7-10, EXCLUDING CHAPTER 14 AND APPENDIX 11A. 3. 2012 IBC 1705.11 CONTRACTOR RESPONSIBILITY: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND CONSTRUCTIONOF A SEISMIC -FORCE -RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR SEISMIC -RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS. ENGERT ARCHITECTURE LL,C 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com W W Z � O =4 w w 0 ....J f:1:: w SOUTHCENTER MALL CONSULTANT 725 POWEU. AVE SW, SUITE 100 RENTON, WA 98057 4. HANGERS AND SEISMIC BRACING FOR THE MECHANICAL SYSTEMS SHALL BE DESIGNED AND PROVIDED BY THE MECHANICAL CONTRACTOR. REFER TO CONTRACTOR SHOP DRAWINGS FOR LOCATIONS OF EQUIPMENT AND HUNG MECHANICAL SYSTEMS. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE SUPPORT SYSTEMS AND DESIGN LOADS FOR HUNG MECHANICAL SYSTEMS WITH THE GENERAL CONTRACTOR AND OTHER TRADES THAT MAY BE IMPACTED. CORRECTION LTR# RECEIVE© CITY OF TUKWILA JAN 31 2019 PERMIT CENTER REVISIONS: 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE / DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: LEGEND AND GENERAL NOTES SM MO.1 SHEET NO: A PLUMBING FIXTURE SCHEDULE TAG FIXTURE MANUFACTURER / MODEL CONNECTIONS NOTES W V CW HW P-1 WATER CLOSET TOTO / CT708EVG 4" 2" 1-1/2" - 1,2,3 P-2 URINAL TOTO / UT447EV 2" 2" 3/4" - 1,4 P-3 BASIN LOVAIR / MAXI SLAB 2" 2" 1/2" 1/2" 1,5,6,7,8 TP TRAP PRIMER PRECISION PLUMBING / P-1 - - 1/2" - - WCO WALL CLEANOUT WADE / 8480-C - - - - - NOTES: 1) REFER TO ARCHITECTURAL ELEVATIONS AND DETAILS FOR MOUNTING HEIGHTS AND INSTALLATION DIMENSIONS. 2) PROVIDE WITH TOTO TET2LA31#SS FLUSH VALVE AND TOTO MODEL #SC534 SEAT. COLOR = "COTTON" 3) PROVIDE WITH ZURN ZN1201-H NARROW WALL CARRIER. 4) PROVIDE WITH TOTO TEU2LA FLUSH VALVE. COLOR = "COTTON" 5) DIMENSIONS OF EACH BASIN VARY. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ALL LAVATORY BASIN DIMENSIONS. 6) BASIN FAUCET SHALL BE LOVAIR L-R021. 7) QUANTITIES OF FAUCET FOR EACH BASIN VARY. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ALL LAVATORY BASIN FAUCET QUANTITIES. 8) PROVIDE EACH INDIVIDUAL FAUCET WITH THERMOSTATIC MIXING VALVES - POWERS HYDROGUARD LFe480 OR APPROVED EQUAL. GRILLE SCHEDULE TAG MANUFACTURER / MODEL TYPE MATERIAL FINISH FACE STYLE FACE SIZE DUCT INLET MOUNTING PATTERN DAMPERS ACCESSORIES NOTES R TITUS / 350RL RETURN / EXHAUST GRILLE ST NOTE 1 - NOTE 2 NOTE 3 NOTE 4 - OBD - - NOTES: 1) COORDINATE WITH ARCHITECT FOR GRILLE COLOR SELECTION. 2) FACE SIZE DETERMINED FROM DUCT INLET SIZE. 3) SEE AIR DEVICE TAG FOR DUCT INLET SIZE. 4) COORDINATE BORDER TYPE (SURFACE MOUNT, SNAP IN, LAY -IN, SPLINE, DROPPED FACE, AND BEVELED DROP FACE) WITH ARCHITECTURAL CEILING PLANS. ABBREVIATIONS: ST = STEEL, AL = ALUMINUM, BE = BAKED ENAMEL, AA = ANODIZED ALUMINUM, FA = FULLY ADJUSTABLE, TP = TWO POSITION, OPD = OPPOSED BLADE DAMPERS, ADJ = ADJUSTABLE, BO = BLANK OFF, DB = DIRECTIONAL BLADES, AND P = PLENUM. ELECTRIC WATER HEATER SCHEDULE TAG MANUFACTURER / MODEL CAPACITY (GAL) RECOVERY AT 90°F (GPH) TEMP SETTING (F) CAPACITY (KW) CAPACITY STAGES (#) CW INLET (IN) HW OUTLET (IN) ELECTRICAL DIMENSIONS (DIAxHT) (INxIN) OPERATING WEIGHT (LBS) NOTES VOLTAGE/PHASE (V/0) EWH-01 RHEEM / XE5OTO6ST45U1 50 21 140 4.5 2 3/4 3/4 240/1 24x60 420 1, 2 PUMP SCHEDULE TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL ELECTRICAL NOTES HP (HP) RPM (RPM) FLA (AMPS) VOLTAGE/PHASE V/0 CP-1 DOMESTIC HOT WATER JANITOR ROOM BELL & GOSSETT / SERIES 100 1/12 1725 1.75 120/1 1 NOTES: 1) PROVIDE WITH PROGRAMMABLE TIMER CONTROLS FOR PROGRAMMED SHUTDOWN. EXPANSION TANK SCHEDULE TAG MANUFACTURER / MODEL VOLUME (GAL) SYSTEM CONN (IN) DIMENSIONS (DIAxHT) (INxIN) OPERATING WEIGHT (LBS) NOTES ET-01 AMTROL / THERM-X-TROL ST-25V 10.3 3/4 16x19 185 1 NOTES: 1) PROVIDE WITH SIGHT GLASS AND SEISMIC RESTRAINTS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA JAN 31 2019 PERMIT CENTER ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com LEVEL ONE w 0 0 ct ct O w SOUTHCENTER MALL CONSULTANT 725 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE / DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: SCHEDULES SM MO.2 SHEET NO: UP TO FC (E)2"WUP (E)4"W 11 II II II III -__�\\ 0 R II A MEN'S ESTROOM L)2' 'j7'' Imo' L ----- r� d II I _ �y I r-1 r—J ! -�__ __ I L-_J it II LL-_4 JANITOR CLOSET (E) 4" W SERVICE HALL WOMEN'S RESTROOM - UNDERGROUND DEMOLITION PLAN MEN'S VESTIBULE SERVICE HALL SCALE: 1/4" =1'-0" SERVICE HALL (E) 4 (E)4"W r III III L J � I J -_--= J L _ J f I l _ JJ WOMEN'S VESTIBULE (E) 4" W MEN'S RESTROOM —UNDERGROUND DEMOLITION PLAN LL== WOMEN'S RESTROOM tfE� \O� C71 411 r-' _J_ 1 II 411 j4471r 711 I!.I —� J4 dif SCALE: 1/4" = 1'-0" GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. CONTRACTOR SHALL NOTIFY LANDLORD OF ANY BUILDING SYSTEM SHUTDOWNS. FLAG NOTES: DEMOLISH EXISTING TOILET CARRIER AND CAP EXISTING WASTE PIPE BELOW, FLOOR. DEMOLISH EXISTING LAVATORY WASTE PIPING AND CAP EXISTING WASTE PIPING BELOW FLOOR. DEMOLISH EXISTING URINAL WASTE PIPING AND CAP EXISTING WASTE PIPING BELOW FLOOR. DEMOLISH EXISTING SINK WASTE PIPING AND CAP EXISTING WASTE PIPING BELOW FLOOR EXISTING FLOOR DRAIN, WASTE AND TRAP PRIMER PIPING TO REMAIN. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 31 2019 PERMIT CENTER ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com SOUTHCENTER MALL CONSULTANT 25 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: EERS 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE/DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018,, - BD 18048 APPROVED: SHEET TITLE: UNDERGROUND DEMOLITION PLAN SM MDI.O SHEET NO: (E) 3/4" CW (E) 2" CW �JAN. J GI G�T� (E)2"CWDN v Il pp) I I o II i 0 O j v,„ / -C — 1 l) 1 \ o �) o fl L L �y (E) 2-1/2' CW WOMEN'S RESTROOM FIRST FLOOR DEMOLITION PLAN SCALE: 1/4" =1'-0" SERVICE HALL MEWS RESTROOM SERVICE HALL 1 (E) 3/4" HWC--��� (E) 1-1/4" HW (E)2"CW J r I ,-. I L I Itl.,� ° i i �1 III III I III (E) " HWC DN III (E) 3/41-1/4" HW DN _% r --1 I II I Ii L J I / ra o ( ) ( ) III u r— L L_ L�_ - - SERVICE HALL MEN'S ESTIBULE (E) 1-1/4" CW DN 1 r—� L 1 WOMEN'S VESTIBULE MEN'S RESTROOM - FIRST FLOOR DEMOLTION PLAN SCALE: 1/4" = 1'-0" L-J WOMEN'S RESTROOM Iv/ J_41111 LC __ _LI_ E D. _h I 10 1 411 0 (E)2"CWDN 1 II _= _ —4=- J� \—(E) EXHAUST DUCT TO (E) CfOFTOP EXHAUST FAN 0 REMAIN. GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. CONTRACTOR SHALL NOTIFY LANDLORD OF ANY BUILDING SYSTEM SHUTDOWNS. FLAG NOTES: DEMOLISH EXISTING WATER CLOSETS AND CARRIERS. REMOVE EXISTING COLD WATER AND VENT PIPING FOR FUTURE CONNECTION TO NEW COLD WATER HEADER AND EXISTING VENT THROUGH ROOF. DEMOLISH EXISTING URINALS AND CARRIERS. REMOVE EXISTING COLD WATER AND VENT PIPING FOR FUTURE CONNECTION TO NEW COLD WATER HEADER AND EXISTING VENT THROUGH ROOF. DEMOLISH EXISTING LAVATORIES. REMOVE EXISTING HOT WATER, COLD WATER AND VENT PIPING FOR FUTURE CONNECTION. DEMOLISH EXISTING SINK AND ASSOCIATED COLD WATER, HOT WATER AND VENT PIPING. CAP EXISTING WASTE PIPING BELOW FLOOR. DEMOLISH EXISTING WATER HEATER AND ASSOCIATED HOT AND COLD WATER. REMOVE EXISTING HOT WATER PIPING FROM DEMOLISHED WATER HEATER TO DEMOLISHED LAVATORIES. REMOVE EXISTING EXHAUST GRILLES IN CEILING AND CAP EXHAUST DUCTWORK FOR FUTURE CONNECTION. REMOVE EXISTING EXHAUST GRILLE AND CAP EXHAUST DUCTWORK SERVING JANITOR ROOM. EXISTING 12x12 DUCT UP TO EXISTING EXHAUST FAN TO REMAIN. EXISTING FLOOR DRAIN AND TRAP PRIMER PIPING TO REMAIN. CAP TRAP PRIMER PIPING IN WALL FOR FUTURE CONNECTION TO NEW TRAP PRIMER. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 072019 City of Tukwila BUILDING DIVISION RECEtVEO, CITY OF TUKW1LA JAN31-2019 PERMIT CENTER ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com W 0 z J 0 W a Z ODwc=n wpLil 0 F— �� J .1 Ct W CONSULTANT E N G NEERS 725 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE/DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: FIRST FLOOR DEMOLITION PLAN SM SHEET N0. MD1.1 11 UP TO (E) FCO (E) 2" W UPS (E) 4" W JAN. CLOSET (105) (E) 4" CONNECT 4" W TO(E)4"W W SEVICE HALL (104) WOMEN'S RESTROOM - UNDERGROUND PLAN 4"WUP 4"WUP CONNECT 2"'VV TO(E)2"W VOMEN'S RESTROOM (103) CONNECT (E) 2" W TONEW 4"W 4"WUP ,-4"WUP 4"WUP,-4"WUP��4"WUP /rUP TO WCO (E) 2"WUP TO (E) FLOOR DRAIN (E) 2"WUP WOMEN'S VESTIBULE (102) SERVICE HALL (101) SCALE: 1/4" = 1'-0" (E) 4" W (E)4"W SERVICE HALL (106) MEN'S RESTROOM - UNDERGROUND PLAN SCALE: 1/4" = 1'-0" CONNECT 4" W TO (E) 4" W 4"WUP— UP TO CI MEN'S VESTIBULE (107) \\=-UP TO (E) FCO MEN'S RESTRCOM (109) MEN'S WASHING (108) 2"WUP UP TO WCO 2"WUP 2"WUP 2"WUP 2"WUP 2"WUP 2"VUP 2"WUP CONNECT 4" W TO (E) 4" W GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. CONTRACTOR SHALL NOTIFY LANDLORD OF ANY BUILDING SYSTEM SHUTDOWNS. FLAG NOTES: RE-ROUTE EXISTING FLOOR DRAIN WASTE AND VENT PIPING AS REQUIRED TO TIE INTO NEW TOILET WASTE AND VENT PIPING. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 31 2019 PERMIT CENTER ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com w 0 Z J Z � Z O cox Q Jw� w Q U w 0 1-= Ct W Ct CONSULTANT ENGINEERS 725 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE/DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: UNDERGROUND PLAN SM MI.O SHEET NO: (E) 2" CW (E) 3/4" CW JAN. CLOSET (105) EWH-01 CP-0�1 E,T-01 CONNECT TO(E)2"C INS IMO M.O. 1-1/4" CW 0 WOMEN'S RESTROOM FIRST FLOOR PLAN (E) 2-1/2" CW SEVICE HALL (104) 2"CWDN CONNECT 2" CW WOMEN'S RE TROOM 103) P-3 CONNECT 1-1/4" CW TO (E) 1-1/4" CW P-1 O- VE OMEN'S 3TIBU (102) SERVICE HALL (101) SCALE: 1/4" = 1'-0" CONNECT 2" CJV TO(E)2"CW SERVICE HALL (106) (E) 3/4" HWC (E) 1-1/4" HW (E) 2" CW MEN'S RESTROOM - FIRST FLOOR PLAN P-3 1 - L - CONNECT TO (E) 1-1/4' -1 MEN'S VESTIBULE 107) 4" HW -'IW EN'S STROOM (109) O12x8 210 3/4,4 L —P- MEN'S WASHING (108) OR12x8 210 CONNECT 2" CW TO(E)2"CW \-1-1/4" (E) EXHAUST DUCT TO (E) CSOFTOP EXHAUST FAN TO REMAIN. CONNECT 2" CW TO (E) 2" CW 1 SCALE: 1/4" = 1'-0" GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO START OF. WORK. 2. CONTRACTOR SHALL NOTIFY LANDLORD OF ANY BUILDING SYSTEM SHUTDOWNS. FLAG NOTES: PROVIDE NEW VENT HEADER IN PLUMBING CHASE AND TIE INTO EXISTING VENT OR EXISTING VENT THRU ROOF. PROVIDE NEW 2" COLD WATER HEADER FOR NEW FLUSH VALVES SERVING WATER CLOSETS AND URINALS. ROUTE LAVATORY COLD WATER AND WASTE IN WALL AND TIE INTO WATER CLOSET CHASE. EXTEND VENT PIPE TO NEW VENT HEADER. ROUTE TEMPERATURE AND PRESSURE RELIEF DRAIN AND DRAIN PAN TO EXISTING ADJACENT MOP SINK. EXISTING 12x12 EXHAUST DUCT THRU ROOF TO EXISTING EXHAUST FAN TO REMAIN. RE -BALANCE SYSTEM TO ACHIEVE AIR QUANTITIES LISTED ON PLANS. EXISTING EXHAUST DUCT ROUTED TO EXISTING ROOFTOP EXHAUST FAN TO REMAIN. VERIFY EXACT LOCATION, SIZE AND ROUTING. RE -BALANCE SYSTEM TO ACHIEVE AIR QUANTITIES LISTED ON PLANS. ROUTE 2" WASTE FROM LAVATORY IN WALL TO 3" WASTE RISER. PROVIDE 20x20 FRAMELESS ACCESS PANEL. 9 PROVIDE NEW TRAP PRIMER (PPP INC. PR-500) IN WALL WITH STAINLESS STEEL ACCESS PANEL. COORDINATE EXACT HEIGHT WITH ARCHITECTURAL ELEVATIONS. RE -CONNECT TO EXISTING TRAP PRIMER PIPING. EXISTING FLOOR DRAIN TO REMAIN. RE -CONNECT TO EXISTING TRAP PRIMER PIPING. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 31 2019 PERMIT CENTER ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com SOUTHCENTER MALL CONSULTANT 725 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: 425-336-2822 www.metrixeng.cam CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE / DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: FIRST FLOOR PLAN SM MI.1 SHEET NO: 12" BEYOND DRAIN IN ALL DIRECTIONS METAL DECK FLASHING. CONFORM TO WATERPROOF MEMBRANE MANUFACTURER. 1 3�I TRAP PRIMER CONNECTION SUMP RECEIVER (WELD TO METAL DECK) METAL DECK FLOOR DRAIN, SET STRAINER LEVEL WITH CONCRETE WEEPHOLE INSIDE CAULK CONNECTION PIPE SIZE AS NOTED ON PLANS CONCRETE 4 as WITH CONCRETE FLOOR DRAIN DETAIL CONSTRUCTION CONCRETE TOPPING SUMP RECEIVER (SET ON CONCRETE) CONCRETE SLAB M2.1 3 SCALE: NONE COUNTER TEMPERED WATER THERMOSTATIC TEMPERING VALVE 1/2" HW SUPPLY FINISHED FLOOR--\ 1/2" CW SUPPLY 1 1/4" O.D. TAILPIECE LOCAL MIXING VALVE DETAIL M2.1 SCALE: NONE 2 SECURED RIM & SCORIATED COVER FINISHED FLOOR INSIDE CAULK CONNECTION SHOWN WITH JOINT GASKET CLEANOUT WITH-LEVELEZE ADJUSTABLE COLLAR; OR APPROVED EQUAL. LEVELEZE ADJUSTABLE COLLAR FLOOR CLEANOUT DETAIL GASKET CLEANOUT PLUG BALANCE OF PIPING SAME AS CLEANOUT TO GRADE M2.1 SCALE: NONE EXPANSION TANK (ET-01) SUPPORT STRAP TO BRACKET OR SUSPEND FROM CEILING WITH THREADED ROD. COLD WATER CHECK VALVE RECIRC — BALANCING VALVE RECIRC. PUMP (CP-1 e �L1 DRAIN PLUG GALVANIZED DRIP PAN BY P.C. 2" STYROFOAM PAD VACUUM RELIEF VALVE ELECTRIC WATER HEATER (EWH-1) t e --120° HOT WATER HEAT TRAP ROUTE 3/4" T&P RELIEF DRAIN ALONG WALL AND DISCHARGE WITH AIR GAP INTO ADJACENT MOP SINK. 4 ELECTRIC WATER HEATER DETAIL MOP SINK M2.1 SCALE: NONE RECEIVED CITY OF TUKWILA JAN 31 2019 REEIMILCENTER REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com w 0 w0 ZQ on DI 2 > 0 w 0 J ft CO Ct W CONSULTANT ENGINEE 725 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: RS 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE/DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: UNDERGROUND DETAILS SM M2.1 SHEET NO: r 2 4v."' irve r 1)3 P'2 p, CONNECT NEW TRAP PRIMER PIPING TO (E) TRAP PRIMER PIPING SERVING (E) FLOOR DRAIN. MEN'S RESTROOM 109 WASTENENT RISER M3.1 SCALE: NONE 1 3v 4 3' 4 V 1 3 V 1 J 1 1 1 1 I `2,, 1 1 1 1 1 . 1 1 1 R OMEN'S RESTROOM 103 WASTENENT RISER M3.1 SCALE: NONE CONNECT NEW TRAP PRIMER PIPING TO (E) TRAP PRIMER PIPING SERVING (E) FLOOR DRAIN. REVIEWED FOR �y CODE COMPLIANCE APPROVED FEB 07 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUUKWILA JAN 31 2019 PERMIT CENTER ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com w 0 LLI 0 0 z J Zp„�z O � w� r Q Ell 2uj 0 -J w� > ittc- w 1:1!: CONSULTANT ENG NEERS 725 POWELL AVE SW, SUITE 100 RENTON, WA 98057 REVISIONS: 425-336-2822 www.metrixeng.com CONSTRUCTION SET 9/24/2018 OWNER CHANGES 11/26/2018 PERMIT REVISIONS 1/30/2019 PHASE / DELIVERABLE Permit Set DATE: DRAWN: PROJECT NO: 8/27/2018 BD 18048 APPROVED: SHEET TITLE: UNDERGROUND WASTENENT RISER SM M3.1 SHEET NO: