Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG19-0021 - SHARETEA - ROUGH-IN, FIXTURES, FAUCETS, ELECTRIC WATER HEATER, GAS PIPING
SHARETEA 100 ANDOVER PARK W 120 PGI 9-0021 Parcel No: Address: City 'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 0223000020 100 ANDOVER PARK W 120 Project Name: SHARETEA Permit Number: PG19-0021 Issue Date: 4/15/2019 Permit Expires On: 10/12/2019 Owner: Name: Address: OPEN FRAME LLC 14900 INTERURBAN AVE 5 #130 C/O JSH PROPERTIES INC, TUKWILA, WA, 98168 Contact Person: Name: SAM MORRIS Address: 700 NW GILMAN BLVD - SUITE 351 , ISSAQUAH, WA, 98027 Contractor: Name: DIAMOND PLUMBING INC Address: PO BOX 267 , BLACK DIAMOND, WA, 98010 License No: DIAMOP1010JK Lender: Name: Address: 1 Phone: (425) 281-1632 Phone: (360) 886-0440 Expiration Date: 1/4/2021 DESCRIPTION OF WORK: SAW CUT CONCRETE FLOOR (APPROX 50 IF) & PATCH; ROUGH -IN & SET OWNER SUPPLIED FIXTURES INCLUDING FAUCETS; WATER HEATER (ELECTRIC) - MOVE (1) EXISTING & ADD (1) NEW; GAS PIPING FOR OWNER SUPPLIED EQUIPMENT Valuation of Work: $23,995.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $396.34 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date. -. (Y I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specofied herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to is permit. Signature: ,r1. STi Date: Print Name: i? r7' /7 l" /J s- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 bA5 PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND Tenant Name: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Guy Permit Project No. Date Application Accepted:.. j3'M Date Application Expires. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: 0223000020 Site Address: 100 ANDOVER PARK W Suite Number: 120 Floor: 1 SHARETEA New Tenant: ® Yes ❑ ..No PROPERTY OWNS Name: AGENT: JSH PROPERTIES, INC Address: 14900 INTERURBAN AVE SE City: TULWILA State: WA Zip: 98168 CONTACT PERSON - person reiving all project utcati?n Name: SAM MORRIS Address: 700 NW GILMAN BLVD #351 City: ISSAQUAH State: WA Zip: 98027 Phone: (425) 281-1632 Fax: Email: samorrisarchl@gmail.com PLUMBING CONTRACTOFORMAT N Company Name: DIAMOND PLUMBING Address: PO BOX 267 City: Black Diamond State: WA Zip: 98010 Phone: (206) 786-0171 Fax: Contr Reg No:: DIAMOPIO I OJK Exp Date: 01/04/2021 Tukwila Business License No.: BUS-0993048 Valuation of Project (contractor's bid price): $ 23,995 Scope of Work (please provide detailed information): Saw Cut Concrete Floor (Approx 50 LF) & Patch; Rough -in & Set Owner -supplied Fixtures Including Faucets; Water Heater (Electric) - Move (1) Existing & ADD (I) New; Gas Piping for Owner -supplied Equipment. Building Use (per Int'l Building Code)- Restaurant/Comm'l Kitchen Occupancy (per Int'I Building Code): B Utility Purveyor: Water: Water District Sewer Public H\Applications\Forms-Applications on Linee201 I Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 5 Fixture Type Qty Dental unut, cusp dor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving l-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PJi]RiNfIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date. Print Name: Charles C. Lindberg, EDI / Enriched Designs Inc. Day Telephone: (425) 255-5467 Mailing Address: 12920 SE 95th Way Newcastle WA 98056 City Zip State HAApplicationsWorms-Applications On Line12011 ApplicationsTlumbing Permit Application Revised 8-9-11.does Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $901.72 M19-0015 Address: 100 ANDOVER PARK W 120 Apn: 0223000020 $505.38 Credit Card Fee $14.72 Credit Card Fee R000.369.908.00.00 0.00 $14.72 MECHANICAL $471:79 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $344.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $94.36 TECHNOLOGY FEE $18.87 TECHNOLOGY FEE R000.322.900.04.00 0.00 $18.87 PG19-0021 Address: 100 ANDOVER PARK W 120 Apn: 0223000020 $396.34 Credit Card Fee $11.54 Credit Card Fee R000.369.908.00.00 0.00 $11.54 GAS $128.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PERMIT FEE R000.322.100.00.00 0.00 $68.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $25.75 PLUMBING $241.25 PERMIT FEE R000.322.100.00.00 0.00 $158.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $48.25 TECHNOLOGY FEE $14.80 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R16784 0.00 $14.80 $901.72 Date Paid: Wednesday, February 06, 2019 Paid By: CHARLES LINDBERG Pay Method: CREDIT CARD 08601E Printed: Wednesday, February 06, 2019 10:20 AM 1 of 1 SYSTEMS CO TUKWIL4 ETRAKIT 8200 5OUTH[ENTER 8LVD TVKWIL8' WA 98188 206'433-1870 CITY OF TUKWILA 0017340808802374464500 Date: 02/06/2019 10:19:53 AM CREDIT CARD SALE MASTERCARD X fCARDHOLDER'S SIGNATURE) z AGREE TO PAY THE x80vc TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit `P4 12, INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type o nspecticIrv: Address: Date Called: A) Special Instructions: Date Wanted: .. Requester: --�� Phone No: pproved per applicable codes. ❑ Corrections required prior to approval. ENTS: Inspect° Date: REINSPECTION FE ' EA.UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Sauthcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request line (206) 438-9350 670 `Project c Type of Inspectic�n_ Addre� �t � �� � W Hate Called: Special Instructions: ' Date Wanted: Requester: 'Phone No: Approved per applicable codes. Corrections required prior to approval. O V ENTS nspecto Date: REINSPECTIO FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 13649 Project: Type of I ectioI _ Address: le, Date al ed: /G Special Instructions: Date Wanted: p.m. Requester. Phone No: 2a:' 7e67 d7a © Approved per applicable codes. COMMENTS: 1?. 'Corrections required prior to approval. nspecto Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ec : fir Ty a of Inspection: A re s: Date Called: Special Instructions: pate Wanted: _„_ a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to a provaI. COMMENTS: :I n s pector: Date: � Zc REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspect on. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100. Tukwila. WA 98188 (206) 431670 Permit Inspection Request Line (206) 438-9350 Project: 6 AZl��c A- R -Type o spection_ I.44!1,? . _ y Address: P° b0,r14, i Date Called: Special Instructions: Date Wanted: P.m - Requester: •-_ ir' 1,1 Phone No:/ - '6 7Y C7c/ proved per applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Rp 1 `? oozl Project: , tfi 4. fl Type of Inspection: eofi &,S . D/1-4,4 Address: ��jj ����[[���� � I cam© �",j.�l.J�/Ls2 _qq ,w, ``,�� PV�Y�Q Da Called: t Special instructions: tom. Date Wanted: f 4 " I, el - `c1 cd.rri... p.m. Requester: Phone No: proved per applicable codes. © Corrections required prior to approval. MMENTS: Inspector: Date: l REINS ION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. dbaSAMorris 700 NW Gilman Blvd #351, Issaquah WA 98027 12 March 2019 Rachelle Ripley, Permit Technician Department of Community Development - Building Division City of Tukwila 6300 Southcenter Boulevard Suite 100 Tukwila WA 98188 RE: Correction Letter #1 PLUMBING/GAS PIPING Permit Application Number PG19-0021 SHARETEA - 100 ANDOVER PARK W - SUITE 120 Subject: Response Submittal Ms. Ripley, This memo is prepared on behalf of Yoon Chang, Chang & Sida LLC, Owners of the above - referenced project, in response to comments in Correction Letter #1 dated 17 February 2019. The original Comments (italicized) appear in their entirety and in the original sequence, to facilitate the review of the Responses (underlined). Drawing revisions have been indicated by cloud (typical) or highlight at the major location on the drawings which are revised, and govern subsequent relevant instances even if overlooked in our Response. Typographical and cleanup corrections are not highlighted, nor are revised layouts, for visual clarity. The attached revision drawings are re -submitted by the architect of record. If you require clarification or have additional questions, please contact us. Sincerely, Sa# Morri4 Sam Morris Principal Project Manager 425-281-1632 samorrisarchl@gmail.com Attachments: 1. Drawing sheets, revised, two (2) copies each: a. M-1.01 Kitchen Exhaust Hood b. P-1.01 Plumbing Plan & Riser Diagrams cc: Yoon Change, Owner 206-355-3720 yooniic@gmail.com Gary Barber, Architect 425-922-1474 garybb.arch@gmail.com Chuck Lindberg, GC 425-255-5467 EDI-Chuck@qwestoffice.net F&Ici 0024 coARECT ON LTR# RECEIVED CITY OF TUKWILA MAR 1 5 2019 PERMIT CENTER dbaSAMorris 700 NW Gilman Blvd #351, Issaquah WA 98027 Page 2 of 3 BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 Comments and Responses re Correction Letter#1 dated 17 February 2019: General Information Note: PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) Noted. "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020. Architects: "date" only not required (WAC 308-12-081). Noted. (BUILDING REVIEW NOTES) 1. Show all plumbing lines supply and DWV on the "proposed floor plan" and show pipe sizes at each run. Indicate what is existing no change and new. Distinguish the different pipe lines from each other with different line types for review clarification. See UPDATED P1.01 Detail 1 Floor Plan - Proposed Detail 2 Floor Plan - Existing Detail 3 Water Supply • 2. Clearly identify all points of connection. Also show a vent before the interceptor. See UPDATED P1.01 Detail 1 Floor Plan - Proposed Detail 2 Floor Plan - Existing Detail 3 Water Supply Detail 4 Waste & Grease Note: there are four (4) vents before the interceptor, one (1) which is closely adjacent. 3. The plan shows all fixtures connected to the grease trap. "Except where otherwise specifically permitted, no wastes other than those requiring treatment or separation shall be discharged into an interceptor." "No food waste disposer or dishwasher shall be connected to or discharge into a grease interceptor". Only equipment that produce grease -laden waste located in areas of establishments where food is prepared, or other establishments where the potential for grease to be introduced into sanitary sewer shall be connected to the grease interceptor. Revise plan to separate out other fixtures not required to empty into the grease interceptor. (UPC 1009.2, 1014.0, 1014.1.2, and 1014.3.2) See UPDATED P1.01 Detail 1 Floor Plan - Proposed Detail 2 Floor Plan - Existing Detail 4 Waste & Grease dbaSAMorris 700 NW Gilman Blvd #351, Issaquah WA 98027 Page 3 of 3 4. Permit indicates 5 gas pipe outlets. Show on the plan gas piping with pipe sizes, sized to the fixtures served and indicate BTU ratings of appliances served in the pipe size calculations. See ADDED P1.01 Detail 5 Gas Piping 5. The exhaust fan serving the Type I hood shall have automatic controls that will activate the fan when cooking the appliance that requires such Type I Hood is turned on, or a means of interlock shall be provided that will prevent operation of such appliances when the exhaust fan is not turned on. Indicate on the plan the interlock for the gas. (2015 IMC 507.1.1) See ADDED M1.01 Note re automatic controls (End of Comments and Responses.) City of Tukwila Department of Community Development February 17, 2019 SAM MORRIS 700 NW GILMAN BLVD - SUITE 351 ISSAQUAH, WA 98027 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG 19-0021 SHARETEA - 100 ANDOVER PARK W Dear SAM MORRIS, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size I lx17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Show all plumbing lines supply and DWV on the "proposed floor plan" and show pipe sizes at each run. Indicate what is existing no change and new. Distinguish the different pipe lines from each other with different line types for review clarification. 2. Clearly identify all points of connection. Also show a vent before the interceptor. 3. The plan shows all fixtures connected to the grease trap. "Except where otherwise specifically permitted, no wastes other than those requiring treatment or separation shall be discharged into an interceptor." "No food waste disposer or dishwasher shall be connected to or discharge into a grease interceptor". Only equipment that produce grease -laden waste located in areas of establishments where food is prepared, or other establishments where the potential for grease to be introduced into sanitary sewer shall be connected to the grease interceptor. Revise plan to separate out other fixtures not required to empty into the grease interceptor. (UPC 1009.2, 1014.0, 1014.1.2, and 10I4.3.2) 4. Permit indicates 5 gas pipe outlets. Show on the plan gas piping with pipe sizes, sized to the fixtures served and indicate BTU ratings of appliances served in the pipe size calculations. 5. The exhaust fan serving the Type I hood shall have automatic controls that will activate the fan when cooking the appliance that requires such Type 1 Hood is turned on, or a means of interlock shall be provided that will 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 prevent operation of such appliances when the exhaust fan is not turned on. Indicate on the plan the interlock for the gas. (2015 IMC 507.1.1) Note: Contingenton response to these corrections, further plan review may request for addition& corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubrnittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, Rache le Ripley Permit Technician File No. PGI9-0021 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0021 DATE: 03/15/19 PROJECT NAME: SHARETEA SITE ADDRESS: 100 ANDOVER PARK E - SUITE 120 Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A C 3-9-1—t1 Building Division NI Public Works Fire Prevention Structural Planning Division Rermit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/19/19 Structural Review Required REVIEWER'S IN TIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/16/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg LJ Fire 0 Ping 0 PW LJ Staff Initials: 12/18/2013 PERMIT COORD COPYo PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0021 PROJECT NAME: SHARETEA SITE ADDRESS: 100 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # DATE: 02/13/19 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Pri Building Division IAN 4/\1 Public Works 01, Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: Planning Division Permit Coordinator DATE: 02/14/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 03/14/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: BI Fire E3 Ping PW Ej Staff Initials: 12/18/2013 City of Tukwila tEVISION SUBMITTALOI Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12 Mar 2019 Plan Check/Permit Number: PG19-0021 Lil Response to Incomplete Letter # EXI Response to Correction Letter # 1 El Revision # after Permit is Issued LI Revision requested by a City Building Inspector or Plans Examiner El Deferred Submittal # Project Name: ShareTea Project Address: 100 Andover Park W 120 Contact Person: Sam A. Morris Phone Number: 425-281-1632 Summary of Revision: In Response to Correction Letter #1 Plumbing/Gas Piping Permit Application Number PG19-0021 dated 17 February 2019: P1.01 - UPDATE Detail 1 Floor Plan - Proposed P1.01 - UPDATE Detail 2 Floor Plan - Existing P1.01 - UPDATE Detail 3 Water Supply P1.01 - UPDATE Detail 4 Waste & Grease P1.01 - ADD Detail 5 Gas Piping M1.01 - ADD Note re automatic controls. RECFIVFD CITY OF TUKWILA MAR 1 5 2019 PERMIT CENTER Sheet Number(s): P-1•01, M-1-01 "Cloud" or highlight all areas of revision includi Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 3) IS WAPermit CentertTemplateaurrnsiRevision Submittal Form.dec Revised: August 2015 Home Eapanol Contact Search L&I Safety & Health Claims & Insurance C:ipWashington State Department of Labor & Industries A-Z Index Help My 1,8z1 Workplace Rights Trades & Licensing DIAMOND PLUMBING INC Owner or tradesperson Principals FIELDS, BERT RANDALL, PRESIDENT FIELDS, LINDA SUSAN, TREASURER Doing business as DIAMOND PLUMBING INC WA UBI No. 601 921 672 P 0 BOX 267 BLACK DIAMOND, WA 98010 360-886-0440 KING County Business type Corporation Governing persons BERT R FIELDS LINDA S FIELDS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. DIAMOP1011.1K Effective — expiration 04/12/1999— 01/04/2021 Bond International Fidelity Ins Co Bond account no. SAIFSU0664626 $6,000.00 Received by L&I Effective date 01/13/2015 01/04/2015 Expiration date Until Canceled Bond history Insurance Ohio Cas Ins Co $1,000,000.00 Policy no. BK057624694 Received by L&I Effective date 01/03/2019 01/30/2017 Expiration date 01/30/2020 Insurance history Savings No savings accounts during the previous 6 year period. Help us improve .... ...... ............ thebondorsavinys No lawsuits against the bond or savings accouti LSI Tax debts during the previous 6 year period. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 958,874-01 Account is current. Doing business as DIAMOND PLUMBING INC Estimated workers reported Quarter 4 of Year 2018 "Less than 1Workers" L&I account contact T4 / MICHELE GARRETT (360)902-4875 - Email: GAM1235©Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve w z LL 0 z 0 L- z Q w w 0 z O a m w m O w Q 0 W LL1 a= co Lu co CZ a, o w #3J ,b O oes F`- 0 Lt! 0 c a. co w co ce cs r U. 0 0 co CC 0- CO CO Lil CC a. LU 0 cc 0 cc 0 0 cc CO 2 U. CC ii O LU 0 0 LLi cc 0 0 N • q O M is U.I Cs W W`re) C CC 1— CD F.. LU al■ R o s s 1311 >- zoo poi i> N- BAN (NO WORK) Existing GREASE INTERCEPTOR ACCESS 64'-8.75" 31'-6.5" L ■ ■ ■ ♦ ♦ a ■ a a 0 ♦ ♦ MN al II Existing °♦ To Remain; ♦ • s • WATER EXISTIN 12'- • • • • • • • • • • b ttl a) 120 D 120A— • MAIN ENTRY SUITE 120 2,232 GSF OCCUPANCY OCCUPANCY CALCULATIONS 120B ALT ENTRY 15" C) ADJACENT TENANT (NO WORK) FLOOR PLAN - EXISTING Scale: 1/4" = 1'-0" ADJACENT TENANT (NO WORK) 4'-5" 2'-1 " WAITING SEPARATE PERMIT REQUIRED FOR: [3r Mechanical E Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION 31'-7" 11" 17'-3.5" 64'-8" EATER ABOVE Era a 7'-1 ti „ X LLI '4684 2" A V 6'-0„ co Jbii4 14'-11" 5'-7.75"' 5' TYP Existing HAND SINK LOW GREASE INTERCEPTOR FRAMING AS NEEDED, TYP ACCESS 122 SERVING 84" H WALL 36" HT WALL 36" WIDE 50" WIDE To Remain 33" H COUNTER ORDER & PICKUP zo 66" WATER HEATER NEW ABOVE 1 S'-4" taiti 4 IKT rC EK,. . .. 318 GSF SS END PANEL 25" x HOOD HT AFF EXHAUST HOOD 4' X 11'-0" ALIGN W/ HOOD SETBACK MAINTAIN ACCESS .`jt��+'*� �i��'�i.�i�•1'e1 �i�''�rr�ifl�s"!r4�4±.f:+i:'���'o�.''�!���'�,�d�.�,s a�! �t <11X3 REVISIONS No changes shall be made to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan rev' • 10 0 FILYCOPY Permit No. L I R -. QQ. Plan review approval is subject to errors and omissions Approval of construction documents does not auth'nze the violation of any adopted code or ordinance. Receipt of approved Field Copy and rC adrt s Is owledg By Date: City O TUKWIIa BUILDIj O I IVI�SION 0 2' 4' 8' LILE-1 RELOCATE EXISTING ELEC RM rWATER HEATER ABOVE EXISTING RELOCATED MOP SINK TO REMAI 124 DRY STORAGE cc; 112 GSF � « " 12 -8„ 3'`4" ri►ri' i 18'-4"• 0 I • • �i�i�i''#?i'_',i7iinri"!.i'i` a ewro �i 4 isi'!•!'��.►'l'#'a��'i`'i�i'i�i'!i�ir i!+!►�l� �i �'i��"i''a!a!i •ski ref 43" H COUNTER M 48" 19'-2" = C 43„ H COUNTER M1/10 223 GSF 121 SEATING 322 GSF ADJACENT TENANT (NO WORK) 48" HT WALL BENCH TYP FLOOR PLAN -PROPOSED WALLS AND BUILT-IN EQUIPMENT) WITH EGRESS PATH Scale: 1/4" 1'-0" EVIEWED FOR DE COMPLIANC APPROVED 2' GSF iECEVED 4' / PERMIT CENTER 4I) tv9AR 15 2019 a 0 str ILA 8' IMMIMMIEMNINIMI 0 �w mz 7 �~ �c=n Sri o z W W 0 rt PROJECT NO: 18K29 ISSUED / REVISED DATE BUILDING PERMIT SUBMITTAL REVISION 2019-03-12 DATE: 2019-01-31 DESIGN BY: SAM DRAWN BY: AM CHECKED BY: GBB PLUMBING PLAN & RISER DIAGRAMS P1.01 9 OF 9 SHEETS 4 IKT rC EK,. . .. 318 GSF SS END PANEL 25" x HOOD HT AFF EXHAUST HOOD 4' X 11'-0" ALIGN W/ HOOD SETBACK MAINTAIN ACCESS .`jt��+'*� �i��'�i.�i�•1'e1 �i�''�rr�ifl�s"!r4�4±.f:+i:'���'o�.''�!���'�,�d�.�,s a�! �t <11X3 REVISIONS No changes shall be made to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan rev' • 10 0 FILYCOPY Permit No. L I R -. QQ. Plan review approval is subject to errors and omissions Approval of construction documents does not auth'nze the violation of any adopted code or ordinance. Receipt of approved Field Copy and rC adrt s Is owledg By Date: City O TUKWIIa BUILDIj O I IVI�SION 0 2' 4' 8' LILE-1 RELOCATE EXISTING ELEC RM rWATER HEATER ABOVE EXISTING RELOCATED MOP SINK TO REMAI 124 DRY STORAGE cc; 112 GSF � « " 12 -8„ 3'`4" ri►ri' i 18'-4"• 0 I • • �i�i�i''#?i'_',i7iinri"!.i'i` a ewro �i 4 isi'!•!'��.►'l'#'a��'i`'i�i'i�i'!i�ir i!+!►�l� �i �'i��"i''a!a!i •ski ref 43" H COUNTER M 48" 19'-2" = C 43„ H COUNTER M1/10 223 GSF 121 SEATING 322 GSF ADJACENT TENANT (NO WORK) 48" HT WALL BENCH TYP FLOOR PLAN -PROPOSED WALLS AND BUILT-IN EQUIPMENT) WITH EGRESS PATH Scale: 1/4" 1'-0" EVIEWED FOR DE COMPLIANC APPROVED 2' GSF iECEVED 4' / PERMIT CENTER 4I) tv9AR 15 2019 a 0 str ILA 8' IMMIMMIEMNINIMI 0 �w mz 7 �~ �c=n Sri o z W W 0 rt PROJECT NO: 18K29 ISSUED / REVISED DATE BUILDING PERMIT SUBMITTAL REVISION 2019-03-12 DATE: 2019-01-31 DESIGN BY: SAM DRAWN BY: AM CHECKED BY: GBB PLUMBING PLAN & RISER DIAGRAMS P1.01 9 OF 9 SHEETS