Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG19-0056 - BRIDGESTONE - DOMESTIC WATER AND SANITARY DRAIN SYSTEM
BRIDGESTONE 18287 SEGALE PARK B DR PGI 9-0056 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT 3523049119 18287 SEGALE PARK B DR Project Name: BRIDGESTONE Permit Number: Issue Date: Permit Expires On: PG19-0056 4/19/2019 10/16/2019 Owner: Name: Address: , WA, Contact Person: Name: JEFF ESTEP Address: 309 49TH ST NE #A , AUBURN, WA, 98002 Contractor: Name: Address: License No: Lender: Name: Address: TRANSIT PLUMBING INC 309 49TH ST NE SUITE A, AUBURN, WA, 98002 TRANSPI101KK Phone: (206) 423-1925 Phone: (253) 854-4443 Expiration Date: DESCRIPTION OF WORK: INSTALL NEW PLUMBING SYSTEM DOMESTIC WATER AND SANITARY DRAIN SYSTEM. Valuation of Work: $11,000.00 Water District: Sewer District: Fees Collected: $278.51 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 9-11-11 | hea,byoerdfy that | have read and examined this permit and know the same to betrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate orcancel the provisions ofany other state or local laws regulating construction or the performance of work, I am authorized to sign and obtain this development permit and agree tothe conditions attached to this permit. Signature: PhntName:~ 3�v�7�( Date; This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection, PERMIT CONDITIONS; 1: ~**PLUK48|NG/GASPIPING PERMIT O]NDHDONS**~ 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division, 3: All permits, inspection records and applicable plans shall bcmaintained authe job and available tothe plumbing inspector. 4: All plumbing and gas piping systems shall beinstalled incompliance with the Uniform Plumbing Code and the Fuel Gas Code. G: Noportion ofany plumbing system qrgas piping shall beconcealed until inspected and approved, 6: All plumbing and gas piping systems shall hetested and approved axrequired bythe Plumbing Code and Fuel Gas Code. Tests shall beconducted inthe presence ofthe Plumbing Inspector. it shall bethe duty of the holder ofthe permit tomake sure that the work will stand the test prescribed before giving notification that the work isready for inspection, 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision ismade tnprotect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall beinsulated tominimum R'3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall beprotected bysteel nail plates not less than 18gauge, 9: Piping through concrete ormasonry walls shall not besubject toany load from building construction. No plumbing piping shall bedirectly embedded inconcrete nrmasonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected inaccordance with the requirements ofthe building code. 11: Piping inthe ground shall belaid onafirm bed for its entire length. Trenches shall bebachfiUedinthin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cindwrOU'frozen earth, orconstruction debris. IZ: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code o,any other ordinance ofthe jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19,27.170 and the 2006 Uniform Plumbing Code Section 4OJofWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)432'9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wvvw.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: e7/o5 fig /0/050 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: '67 - eia I ;.11€ s+t) e_ PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: , Address: e cis , Co , 4A, acfC) (-- City: State: Zip: Phone: Fax: Email: i -r.Pe 6 King Co Assessor's Tax No.: 9 7 6021 v e__ Suite Number: Floor: New Tenant: 0 Yes 0 ..No PLUMBING CONTRACTOR LNFORMATION - Company Name: rvs 11- i.,, -1- L-c._ Address: 2 0 9 (.1 - sr i City: S LA- I-, State: Zip:9c0 02 Phone:206-.023_ 1 V 5-Fax: 25-3 2(5), .4//,,,73 Contr Reg No.. n fif / p Date: Tukwila Business License No.: q see Valuation of Project (contractor's bid price): $ 000 Scope of Work (please provide detailed information): V-G x.144k,c-LLC-e)c- (32W9 c Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: HAApplicationsVorms-Applications On Linek2011 Applications \Plumbing Permit Application Revised 11-9-11.doc-s Revised: August 2011 bh Page I of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) L Lavatory 2- Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow _protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet . .,.. Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NO 1'ES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: Print Name: Mailing Address: Date: ~ 2 _ `9 Day Telephone: 2 t-G- 1/2 1 / 2'3 - �b„ N �� 9 o i City State Zip HAApphcationsWorms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8.9.11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID 224,95 PG19-0056 Address: 18287 SEGALE PARK B DR Apn 3523049119 $224,95 Credit Card Fee $6.55 Credit Card Fee R000.369.908.00.00 0.00 $6.55 PLUMBING $208.00 PERMIT FEE R000.322.100.00.00 0.00 $173.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $10.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17447 R000.322.900.04.00 0.00 $10.40 $224.95 Date Paid: Friday, April 19, 2019 Paid By: JOHN PERRIN Pay Method: CREDIT CARD 00293G Printed: Friday, April 19, 2019 12:02 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $53.56 PG19-0056 Address: 18287 SEGALE PARK B DR Apn: 3523049119 $53.56 Credit Card Fee $1.56 Credit Card Fee R000.369.908.00.00 0,00 $1.56 PLUMBING $52,00 PLAN CHECK FEE R000.322.103.00.00 0.00 $52.00 TOTAL FEES PAID BY RECEIPT: R17349 $53.56 Date Paid: Friday, April 05, 2019 Paid By: TRANSIT PLUMBING INC Pay Method: CREDIT CARD 07620G Printed: Friday, April 05, 2019 1:17 PM 1 of 1 SYSTEMS 0 X CO TUKWIL4 ETRAoIT 6200 S0UT*[ENTsn aLvo TUmazLx, wx 98188 206-433'1870 CITY OF TUKW3L4 0017340000802374464500 Date: 04/19/2019 12:02:36 PM CREDIT CARD SALE **+^****+4441 K $224.95 00293G 000 jazzel {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT AC[0nozmG TO THE CARD ISSUER AGREEMENT Thank you! Merchant Copy CO TUKWILA ETKAKIT 6208 S0UTMCENTER 8LVD TVKWILx^ WA 98188 200'433'1870 CITY OF TUKNILx Date: 04/05/2819 01:10:36 PM [xsozT [xeD SALE VISA CARD NUMBER: **********4441 K TnAN AMOUNT: $53.56 xppn0VAL [D: 87620G RECORD #: 000 CLERK ID: Laurie Thank you! Customer Copy CO TUKWILA ETnAKIT 6200 50uTM[Em7sR BLvo TuxuILA' W4 98188 206'433'1870 CITY OF TUxWILA Date: 04/19/2019 12:02:3e PM CREDIT CARD SALE VISA CARD NUMBER: *******+**4441 K TK4N AMOUNT: $I24'95 APPROVAL CD: 80293G RECORD #: 000 CLERK ID: jazzel Thank you! Customer Copy STATE OF WASHINGTON BUSINESS LICENSING SERVICE Thank you for filing online Our processing time generally takes up to 10 business days. Some endorsements may take more time for state or city approval. You will receive your business license with approved endorsements in the mail. An updated business license will be mailed to you when additional endorsements are approved. Confirmation Number: 0-007-794-531 Filing Date and Time: 04/03/2019 09:23:32 AM Payment Method: ACH Debit/E-Check Business Entity Information Entity Type: Corporation Name of Entity: TRANSIT PLUMBING, INC. AccountlD: 601216965-001-0001 Firm Name: TRANSIT PLUMBING, INC. Endorsement(s) Applied For Commence Cease Count Fee Tukwila General Business - Non -Resident 04/03/2019 04/30/2020 1 $100.00 $100.00 Fee Type Commence Cease Count Fee BLS Processing Fee 04/03/2019 1 $19.00 $19.00 Grand Total: $119.00 tx1-0004 INSPECTION NO, INSPECTIION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6340 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projecx, N. T f Inspection: Mrifilif Address: 1?2J7 , Date Called: Sp 'al Instruct ' s: ' Date Wanted: K,---- t 4 Z-6 a.m. p.m.. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. 01 MENTS: ns pecto Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectior . INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 1627ZPX1 ezi. j PAS Date Called: 6 Special Instructions: Date Wanted: a�.n Requester: Phone No: %5j? 5_ pproved per applicable codes. Inspe Corrections required prior to approval. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit N5 ' N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 Project. r Type of Inspion: Address: JgZ8 7 Date alled: Special Instruct! n Date. 'canted: a.m. p.m. RequesE... Phone NoP y f 5 z + Approved per applicable codes. Corrections required prior to approval. OMMENTS: nspecto Date: Zz2d REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ?EflWHT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0056 DATE: 04/05/19 PROJECT NAME: BRIDGESTONE SITE ADDRESS: 18287 SEGALE PARK DRIVE X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: At- L1'114( Building Division a -soy .0t,toi Public WAs Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/09/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 05/07/19 Notation: REVIEWER'S INIT A S: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire Ej Ping 0 PW E Staff Initials: 12/18/2013 Flom Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries A-Z Index Help Mp L&l Workplace Rignts Trades & Licensing TRANSIT PLUMBING INC Owner or tradesperson Principals ESTEP, JEFF D, MEMBER Doing business as TRANSIT PLUMBING INC WA UBI No. 601 216 965 309 49TH ST NE STE A AUBURN, WA 98002-1414 253-854-4443 KING County Business type Corporation Governing persons JEFF DUANE ESTEP GAIL M BUOL; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties PLUMBING License no. TRANSPI101 KK Effective — expiration 05/12/1990— 08/09/2019 Bond CBIC Bond account no. SI2884 Active.. Meets current requirements. $12,000.00 Received by L&I Effective date 05/11/2009 05/05/2009 Expiration date Until Canceled Insurance Kinsale Insurance Company $2,000,000.00 Policy no. 0100055088-1 Received by L&I Effective date 08/23/2018 08/25/2018 Expiration date 08/25/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve No L&I tax debts are recorded for this contra may be recorded by other agencies. License Violations icense during the previous 6 year period, but some; > Infraction no. PFORK00242 Issue date 06/19/2018 Violation city AUBURN Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Infraction no. PFORK00241 Issue date 06/1912018 Violation city AUBURN Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Satisfied RCW/WAC 18.106.020 Violation amount $250.00 Satisfied RCW/WAC 18.106.020 Violation amount $250.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 546,719-01 Doing business as TRANSIT PLUMBING INC Estimated workers reported Quarter 4 of Year 2018 "31 to 50 Workers" L&I account contact T1 / NICHOLE CAROW (360)902-5634 - Email: CANI235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bld No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Washington State Dept of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve ABBREVIATIONS SYMBOLS PROJECT DIRECTORY APPROVED BY:. V J 1 It AB AC A/C ACP ACT ADH ADJ AF AFF AHJ AL ALT ANGLE CENTER UNE DIAMETER OR ROUND NUMBER OR POUND PENNY PERPENDICULAR PLATE ANCHOR BOLT ACOUSTICAL AIR CONDITIONING ACOUSTICAL CEILING PANEL ACOUSTICAL TILE ADHESIVE ADJACENT ACCESS FLOOR AT/ABOVE FINISH FLOOR AUTHORITY HAVING JURISDICTION ALUMINUM ALTERNATE AP ACCESS PANEL APC ACOUSTICAL PANEL CEILING APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT BD BOARD BETW BETWEEN BLK BLOCK BLDG BUILDING BM BEAM BRG BEARING BOT BOTTOM BSMT BASEMENT BUR BUILT UP ROOF CAB CB CBU CEM CER CFM CFT CG CHBD CI CJT CLF CLG CJ CLK CLO CLR CMU CNTR CO COL CONC CONSTR CONT CORR CPT CT CTR CY DBL DEPT DF DIA DIAG DIM DISP DN DR DTL DWR DS DW DWG E EA B EJ EL ELEC ELEV EM EMER ENCL EP EWC EPX EQ EQUIP EST EX EXIST EXT FA FBO FCIC FCTY FD FDN FE FEC FF FIN FL FLG 17-067 T1.1 (COVER SHEET - SMALL).dwg CABINET CATCH BASIN CEMENTTTIOUS BACKER UNIT CEMENT CERAMIC CUBIC FEET PER MINUTE CONDUCTIVE FLOOR TILE CORNER GUARD CHALK BOARD CAST IRON CONTROL JOINT CHAIN LINK FENCE CEILING CONSTRUCTION JOINT CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT COUNTER CLEANOUT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CORRIDOR CARPET CERAMIC TILE CENTER CUBIC YARD DOUBLE DEPARTMENT DRINKING FOUNTAIN(W/0 COOLER) DIAMETER DIAGONAL DIMENSION DISPENSER DOWN DOOR OR DRAIN DETAIL DRAWER DOWNSPOUT DISHWASHER DRAWING EAST EACH EXPANSION BOLT EXPANSION JOINT ELEVATION ELECTRIC ELEVATOR ENTRY MAT EMERGENCY ENCLOSURE OR ENCLOSED ELECTRICAL PANEL ELECTRIC WATER COOLER EPDXY EQUAL EQUIPMENT ESTIMATE EXPANSION EXISTING EXTERIOR FIRE ALARM FURNISHED BY OTHERS FURNISHED BY CONTRACTOR INSTALLED BY CONTRACTOR FACTORY FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FACTORY FINISH FINISH FLOOR FLASHING FURR FUT FUTURE- RIO GA GALV GB GC GL GLB GND GR GWB HB HC HDR HDWD HDWE HM HORIZ HR HT HTG HVAC HWH BC D EC FC HM N NCL NSUL NT PC JAN JT KIT KO KS LAM LV B LF LG LH LINO LKR LT MACH MATL MAX MECH MEZZ MFR MH MIN MIR MISC MLD MRGWB MTD MIL MULL N NIC OM# NTS OA OC OD OFF OH OPH OPNG OPP PERP PFN PL PLAM PLYWD PNL PNT PR FLUOR FLUORESCENT FM FACTORY MUTUAL FOC FACE OF CONCRETE FOF FACE OF FINISH FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR F010 FURNISHED BY OWNER INSTAI I FD BY OWNER FOS FACE OF STUD FS FULL SIZE FT FEET FTG FOOTING F11C FURNISHED BY TENANT INSTALLED BY CONTRACTOR FTIO FURNISHED BY TENANT INSTALLED BY OWNER FURRING FUTURE FUTURE ROUGH IN ONLY GAGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GLASS OR GLAZING GLU-LAM BEAM GROUND GRADE GYPSUM WALL BOARD HOSE BIB HOLLOW CORE OR HANDICAP HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING HEATING/VENTILATION/ AIR CONDTONING HOT WATER HEATER NTERNATIONAL BUILDING CODE NSIDE DIAMETER/ DIMENSION NTERNATIONAL ELECTRIC CODE COUNCIL NTERNATIONAL FIRE CODE NSULATED GLAZING NSULATED HOLLOW METAL NCH NCLUDE NSULATION NTERIOR NTERNATIONAL PLUMBING CODE JANITOR JOINT KITCHEN KNOCK OUT KNEE SPACE LAMINATE LAVATORY LAG BOLT LINEAL FOOT LENGTH LEFT HAND LINOLEUM LOCKER LIGHT MACHINE MATERIAL MAXIMUM MECHANICAL MEZZANINE MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLANEOUS MOLDING MOISTURE RESISTANT GWB MOUNTED METAL MULLION NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER/ DIMENSION OFFICE OVERHEAD OPPOSITE HAND OPENING OPPOSITE PERPENDICULAR PREFINISHED PLATE OR PROPERTY LINE PLASTIC LAMINATE PLYWOOD PANEL PAINT PAIR PS PAINT SYSTEM PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED PTD PAPER TOWEL DISPENSER PTD/R PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVMT PAVEMENT QT QUARRY TILE RA RAD R&S RB RCP RD RD/0 REBAR REF REFR REINF REQ'D REV RH RESIL RM RO RT RUB RW RWL S SC SCD SCHD SD SECT SF SHTG SIM SNK SLR SND SNR SPEC SQ SST SSK sr STA STC STD STL STOR STRL SUSP SV SYM TB T&B TG THK TIG TO TOC TOP TOS TOSL TOW TPD TPH TS TPTN TV TYP UL UNF UON UR VAR VCT VERT VEST VIN VWC RISER RETURN AIR RADIUS ROD & SHELF RESILIENT BASE REFLECTED CEILING PLAN ROOF DRAIN ROOF DRAIN OVERFLOW REINFORCING BAR REFERENCE REFRIGERATOR REINFORCED REQUIRED REVISION RIGHT HAND OR ROBE HOOK RESILIENT ROOM ROUGH OPENING RESILIENT 11LE RUBBER RAIN WATER RAIN WATER LEADER SOUTH SOLID CORE SEAT COVER DISPENSER SCHEDULE SOAP DISPENSER SEC11ON SQUARE FEET SHEATHING SIMILAR SINK SEALER SANITARY NAPKIN DISPENSER SANITARY NAPKIN RECEPTACLE SPECIFICATION SQUARE STAINLESS STEEL SERVICE SINK STONE/STONE TILE STATION SOUND TRANSMISSION CLASS STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SHEET VINYL SYMMETRICAL TREAD TOWEL BAR TOP & BOTTOM TEMPERED GLASS THICK TEMPERED INSULATED GLAZING TOP OF TOP OF CONCRETE TOP OF PAVEMENT TOP OF STEEL TOP OF SLAB. TOP OF WALL TOILET PAPER DISPENSER TOILET PAPER HOLDER TOILET PARTITION TUBULAR SIELL TELEVISION TYPICAL UNDERWRITERS LABORATORY UNFINISHED UNLESS OTHERWISE NOTED URINAL VARIES VINYL COMPOSITION TILE VERTICAL VESTIBULE VINYL VINYL WALL COVERING W WEST W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WF WIDE FLANGE WG WIRE GLASS WHSE WAREHOUSE WP WATER PROOF WR WATER RESISTANT WSCT WAINSCOT WT WEIGHT XFMR TRANSFORMER YD YARD 107B WT $-* COLUMN LINE/GRID UNE DOOR/RECITE NUMBER CORRESPONDS TO ROOM ENTERING KEY NOTE PARTITION TYPE REVISION NUMBER REVISION CLOUD AROUND REVISION MATCH UNE SHADED PORTION IS THE SIDE CONSIDERED WORK POINT, CONTROL POINT OR DATUM POINT 0 492. EQUIPMENT NUMBER BUILDING SECTION SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN DETAIL SECTION SEC11ON IDENTIFICATION SHEET WHERE SECTION IS DRAWN DETAIL OR ENLARGED PLAN DETAIL IDENTIFICATION SHEET WHERE DETAIL IS DRAWN GENERAL NOTES WINDOW SYMBOL INTERIOR ELEVATION(S) ELEVATION IDENTIFICATION SHEET WHERE ELEVATION IS DRAWN TITLED ROOM IDENTIFICATION TITLE2 TITLE3 ROOM NAME ROOM ROOM NO. 1 +8'-6" 78 71 FINISHED CEILING HEIGHT PROPERTY UNE NEW OR FINISHED CONTOURS EXISTING CONTOURS TOP OF WALL TOP OF CURB TOP OF PAVEMENT PROJECT NORTH 9'-0" DENOTES CHANGE IN ELEVATION 7'-O" FINISH SYMBOL 1. THE GENERAL CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. 3. THE GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THAT OF OTHER SEPARATE CONTRACTS SUCH AS SIGNS, & OWNER FURNISHED ITEMS, WHICH ARE BEING DONE BY OTHERS. 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDI1ONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 5. SEPARATE PERMITS, WHEN REQUIRED AND/OR WHEN WORK ITEMS ARE DESIGN/BUILD IN NATURE, SHALL BE OBTAINED BY THE CONTRACTOR FOR MECHANICAL PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND REQUIRED SUBMITTAL DOCUMENTS INFORMATION SHALL BE PROVIDED FOR REVIEW BY THE REGULATING AUTHORMES AND BY THE OWNER/TENANT/ARCHITECT FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. SEE SPECIFICATIONS FOR REQUIREMENT FOR DESIGN/BUILD FIRE SPRINKLER SYSTEM. SUBMIT PLAN TO AND OBTAIN PERMIT FROM THE AUTHORITY HAVING JURISDICTION FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODIFICATION. ALL WORK SHALL COMPLY WITH CURRENT GOVERNING CODES. 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE BUILDING OFFICIAL SHALL BE PERFORMED BY INSPECTORS APPROVED BY THE BUILDING OFFICIAL 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. ANY MODIFICATIONS TO WORK SHALL BE INDICATED ON FIELD "AS -BUILT" SET OF DOCUMENTS. 8. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UON. 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 11. GENERAL CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT WITH DETAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER AND ARCHITECT. 12. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH CURRENT GOVERNING CODES. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED AS TO PERMIT WORK WHICH IS NOT CONFORMING TO CURRENT GOVERNING CODES. 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICE PROVIDERS, PUBLIC AND/OR PRIVATE. 15. FIRE BLOCKING SHALL BE PROVIDED AT ALL FRAMED WALLS AT 10'-0" O.C. AND ALSO AT ANY LOCATION WHERE WALL FRAMING PENETRATES CEILINGS. REFER TO IBC SEC. 708 FIRE BLOCKING AND DRAFT STOPS FOR CONSTRUCTION. 16. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND AFFECTED BY NEW CONSTRUCTION. 17. ASBESTOS AND HAZARDOUS WASTE EXCLUSION: THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND RELATED TO THE INVESTIGATION DETECTION. PLUMBING FIXTURE REO'S ARCHITECT/CONTACT: OWNER: GENERAL CONTRACTOR: VICINITY MAP NTS CRAFT ARCHITECTS, PLLC. 2505 THIRD AVE, STE. 324 SEATTLE, WASHINGTON 98121 CLARION, SEATTLE SOUTH BUSINESS PARK TBD Ast,ey 1 mn:Itl•B Hom4:1,iv GDzjaH to 9 Tire HC , . S IF:,,::., 5:;1a v CosmeNIA9 TAX PARCEL # 870021-0120 LEGAL DESCRIPTION TUKWILA BSIP L17-0011. PLAT LOT: 12 CODE/ZONING INFORMATION GOVERNING BUILDING CODES: 2015 IBC 2015 UPC 2015 IFC 2009 ICC/ANSI A117.1 (ACCESSIBILITY) 2015 IECC REGULATIONS & ORDINANCES 2015 WASHINGTON STATE AMENDMENTS 2015 WASHINGTON STATE ENERGY CODE 2015 IMC ZONING DISTRICT: EXISTING OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: SPRINKLER SYSTEM: FLOOR AREA: FIRST FLOOR OFFICE (NEW) (B) WAREHOUSE (EXISTING) (S-1) TOTAL FLOOR AREA: OCCUPANCY WATER CLOSETS/URINALS LAVATORIES DF RATIO USE LOAD RATIO MALE FEMALE SINGLE OCCUPANCY RATIO MALE FEMALE SINGLE OCCUPANCY OFFICE (B) 15 1 PER 25 FIRST 50; THEN 1 PER 50 EXCEEDING 50 (7.5)-0.3 REQ (7.5)-0.3 REQ OCCUPANT LOADS OF 15 OR LESS CAN BE SERVED WITH ONE RESTROOM 1 PER 40 FIRST 80; THEN 1 PER 80 EXCEEDING 80 (7.5)-0.19 REQ (7.5)-0.19 REQ OCCUPANT LOADS OF 15 OR LESS CAN BE SERVED WITH ONE RESTROOM 1 FOR ANY OCCUPANCY EXCEEDING 30 FOR THE FIRST 150 OCCUPANTS; 1 ADDITIONAL FOR EACH 500 OCCUPANTS WAREHOUSE (S) 33 1 PER 100 (16.5)-0.17(16.5)-0.17 REQ REQ 1 PER 100 (16.5)-0.17(16.5)-0.17 REQ REQ REQUIRED TOTALS 0.47 0.47 - 0.36 0.36 - 1 TOTAL PROVIDED - - 2 - _- 2 2 HI (HEAVY INDUSTRIAL) B (0FFICE)/S-1 (WAREHOUSE) III-B FULLY SPRINKLERED 1,499 SQ FT 16,542 SQ FT 18,041 SQ FT CONTACT: PHONE: EMAIL: CONTACT: PHONE: EMAIL: JESSICA BRADLEY (206) 720-7001 JESSICA@CRAFTARCHITECTS.COM PATRICE JENSEN (253) 398-9004 PATRICE.JENSEN@CBRE.COM CONTACT: TBD PHONE: EMAIL SEPARATE PERMITAND APPROVAL REQUIRED Initials Date SEPARATE PERMIT REQUIRED FOR: ® Mechanical ts Electrical ❑ PIut bing Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED APR 112019 City of Tukwila UILDING DIVISIO SITE/BUILDING PLAN //fir///// 1 AREA OF WORK rrrrrrmmrrrr .pow - Pmmmummmr X PROJECT DESCRIPTION IBM TENANT ALTERATION CONSISTING OF: • ADDITION OF NEW SPECULATIVE OFFICE SPACE WITHIN EXISTING WAREHOUSE • NEW ACCESSIBLE ROUTE TO SUITE ENTRANCE • NEW EXIT AT REAR OF SUITE INDEX OF DRAWINGS T1.1 GENERAL INFORMATION & SITE PLAN T1.2 ACCESSIBILITY GUIDELINES A0.1 ARCHITECTURAL SITE/EGRESS/WAREHOUSE PLAN A2.1 FLOOR & PLANS A2.2 REFLECTED CEILING PLANS A3.1 EXTERIOR ELEVATIONS & DETAILS A5.1 INTERIOR ELEVATIONS & DETAILS A6.1 DOOR & FINISH SCHEDULE A8.1 WALL TYPES FILE COPY Permit No. G 005lQ Plan review approval is subject to errors and omissions Approval of construction aocuments does not auth rize the vtoiation of any adopted code or ordinance. Receipt of approved Field Copy and dit; ns is nowiedgea: By. Dat (. fq-ff City of Tukwila BUILDING DIVISION PARKING REQUIREMENTS 1,499 SQ FT OFFICE @ 2.5/1000 16,542 SQ FT WAREHOUSE 0 1/2000 TOTAL STALLS REQUIRED ACCESSIBLE STALLS REQUIRED TOTAL STALLS PROVIDED ACCESSIBLE STALLS PROVIDED 4 STALLS 9 STALLS RECEIVED CITY OF TUKWILA APR 05 2019. 13 STALLS PERMIT CENTER 1 STALLS 29 STALLS 2 STALLS SEPARATE PERMIT SUBMITTALS ELECTRICAL, MECHANICAL PLUMBING, FIRE ALARM, SPRINKLER AND RACKING WORK. LIGHTING REQUIREMENTS SCOPE OF WORK TO MEET OR EXCEED CURRENT WA STATE LIGHTING REQUIREMENTS PER ATTACHED WSEC SPREADSHEET ENERGY REQUIREMENTS SCOPE OF WORK TO MEET OR EXCEED CURRENT WA STATE ENERGY REQUIREMENTS PER ATTACHED WSEC SPREADSHEET SHELL IS A SEMI -HEATED BUILDING AS DEFINED BY THE 2015 WASHINGTON STATE ENERGY CODE. WAREHOUSE SPACE TO BE HEATED BY GAS FIRED UNIT HEATERS WITH A MAXIMUM OUTPUT OF 8 BTUH/SF; COOLING IS NOT PROVIDED. OFFICE SPACE TO BE FULLY CONDITIONED. SLAB INSULATION IS EXCLUDED. H Oo56 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www. craftarch itects. com C : RE Settle South BP 0 J W, 1LL O � W 11- co W VJ N < V � rW� .� a) m TUKWILA, WASHINGTON CONSULTANT Submittals/Revisions: FOR PERMIT 11/02/18 Sheet Title: GENERAL INFORMATION & SITE PLAN Date: 10/31/18 Design: Drawn: Project No: 18-164.06 Approved: KCR Building No: T1.1 Sheet No: COPYRIGHT CRAFT ARCHITECTS 2018 GENERAL NOTES: iota,; v K. kc Altoe sr .' Pic Wat' XP 1` s g6- " 6^S&.3 tNtc yam+ o e x 5zie. K 2 i DF R‘ 5e l' 1 11(2_6 fr aLov 309 49th St N.E.#A Auburn, We. 98002 Phone. 253-854-4443 F,,v 9rq_Rr, 471 31y& .-taT wate>r ro Vafiuv vSU iatt It Dr- Lov 2 We- 1 ��2 1 We- 10' ClfcotO+'0`.\) ,Ip c K j.P R '4 cc) I$ v y .\3 50'-0" 0- I� 0A OPEN OFFICE 100 26'-2" OFFICE 1 106 A 105 10'-4" \ \ 12'-10" I +72" +72' CONF. ROOM 104 01.<4 ek is+ 5 et? v oov�) . jT )Pc � G� 70 21'-11" gad 0A BREAKROOM ,108 0 T 1 1 EXISTING WAREHOUSE Rfrvox, lso 1- +BOG FLOOR PLAN 1 /8" = 11-0" b 0 N b 0 In N 3/L k ' S1-"" s of toys 1. WHERE' NEW FLOOR FINISHES AND/OR WALL BASE ARE SCHEDULED, PREPARE FLOORS AND WALLS TO RECEIVE NEW FINISH. CONCRETE SLAB TO RECEIVE NEW SEAL WHERE SAW -CUT AND PATCHED. PATCH AND PAINT ALL OFFICE WALLS. TYPICAL THROUGHOUT. 2. FINISHES PER ROOM FINISH SCHEDULE SHEET A6.1. TYPICAL UON. 3. REUSE EXISTING DOORS, DOOR FRAMES AND DOOR HARDWARE IN NEW CONFIGURATION WHENEVER POSSIBLE. NEW DOORS AND DOOR FRAMES TO MATCH EXISTING. 4. ALL NEW PARTITIONS TO BE WALL TYPE 1 B UON, SEE SHEET A8.1 FOR WALL TYPES. 5. FOR ACCESSIBILITY COMPLIANCE REFER TO SHEET T1.2. 6. THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH ONES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRUCTION ON THE DRAWING. 7. OFFSET STUDS. WHERE REQUIRED. SO THAT FINISHED PARTITION SURFACE WILL BE FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTIt10NS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS.. 8. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS OR DETAILS ARE TO BE (4) INCHES FROM ADJACENT WALL AT HINGE SIDE OF DOOR OR CENTERED BETWEEN WALLS. 9. FINISHED FACES OF NEW PARTITIONS PARALLEL TO EXISTING FRAMING SHALL ALIGN. 10. CENTER LOCATION OF NEW WALL CONSTRUCTION ON EXISTING COLUMNS, PIER, JOISTS OR WINDOW MUWON, AS SHOWN. 11. GC SHALL BE RESPONSIBLE FOR PROVIDING ALL BLOCKING FOR ALL WALL AND CEILING MOUNTED ITEMS, INCLUDING HARDWARE, UGHT FIXTURES, GRAB BARS, CASEWORK, AND ALL OWNER PROVIDED ITEMS. PROVIDE SHEET METAL REINFORCING (8" HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANIZED SHEET METAL) CONCEALED IN PARTITIONS WHERE WALL OR CEILING MOUNTED ITEM IS INDICATED ON DRAWINGS. 12. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW PRIOR TO MANUFACTURE OF ANY CASEWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATED WORK. 13. SEE ALSO ENGINEERING DRAWINGS (IF PROVIDED) FOR ADDITIONAL INFORMATION. WHEN THERE ARE DISCREPANCIES BETWEEN ARCHITECTURAL, ELECTRICAL, MECHANICAL OR PLUMBING DRAWINGS OBTAIN CLARIFICATION FROM ARCHITECT IN WRMNG BEFORE PROCEEDING WITH ANY WORK IN QUESTION OR RELATED WORK. IF WORK IS PERFORMED PRIOR TO OBTAINING CLARIFICATION, CONTRACTOR SHALL CORRECT CONFLICTING WORK AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR THE ARCHITECT. 14. EACH ROOM SHALL COMPLY WITH THE PROVISIONS OF C405.2.1.1 INTERIOR LIGHTING CONTROLS. SEE ALSO A0.1 FOR WAREHOUSE POWER/DATA. 15. ALL SWITCHES, RECEPTACLES, COVER PLATES AND OTHER ELECTRICAL DEVICES SHALL BE WHITE IN COLOR, UON. DEVICES WHICH OCCUR IN STAINED MILLWORK OR ON BLACK COLORED SURFACES SHALL BE BLACK IN COLOR. ALL EXISTING BEIGE SWITCHES, RECEPTACLES, COVER PLATES AND OTHER ELECTRICAL DEVICES SHALL BE CHANGED TO WHITE. 16. RECEPTACLES WITHIN 6' OF A WATER SOURCE SHALL BE GFI TYPE. 17. ALL FURNITURE AND WORKSTATIONS PROVIDED AND INSTALLED BY OWNER. NEW FURNITURE PANELS WILL BE POWERED. ELECTRICAL CONTRACTOR TO PROVIDE PANEL TO PANEL ELECTRICAL CONNECTIONS, POWER CONNECTION TO WORKSTATIONS (WHIPS/BASE POWER INFEEDS) AND DUPLEX RECEPTACLE INSTALLATION. COORDINATE POWER, VOICE/DATA AND SECURITY LOCATIONS AND INSTALLATION REQUIREMENTS W/ FURNITURE VENDOR, TYP. 18. ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15" ABOVE FLOOR UON. 19. ALL CORE DRILL LOCATIONS SHALL BE VERIFIED WITH DESIGNER PRIOR TO DRIWNG. 20. MAINTAIN A FOUR INCH HORIZONTAL CLEARANCE IN ALL DIRECTIONS, MIN. FROM EDGE OF COVER PLATE, FOR WALL MOUNTED OUTLETS, OR FROM EDGE OF MONUMENT FOR FLOOR MOUNTED OUTLETS, WHEN ADJACENT TO A WALL, COLUMN, OR SIMILAR ELEMENTS, UON. 21. INDICATED DIMENSIONS ARE TO THE CENTER OF THE COVER PLATE OR MONUMENT: CLUSTERS OF OUTLETS ARE DIMENSIONED TO THE CENTER OF THE CLUSTER, UON: GANG COVER PLATES SHALL BE ONE-PIECE TYPE UON. 22. ALL EXISTING ELECTRICAL/ TELEPHONE OUTLETS NOT SHOWN ARE EXISTING TO REMAIN. POWER Sc COMMUNICATION OUTLETS ARE SHOWN IN IDEAL LOCATIONS. REUSE EXISTING ELECTRICAL/ TELEPHONE OUTLETS WHEN LOCATED NEAR IDEAL LOCATIONS AND RELOCATE EXISTING ELECTRICAL/ TELEPHONE OUTLETS WHERE POSSIBLE. 23. FURNITURE SHOWN IS FOR REFERENCE ONLY AND IS NIC. LOCATION OF OUTLETS IN PRIVATE OFFICES TO BE COORDINATED WITH FURNITURE VENDOR. LEGEND: tzGc os EXISTING PARTITION TO REMAIN NEW PARTITION WALL MOUNTED DUPLEX OUTLET: DED OR HATCH = DEDICATED 20A = 20 AMP CIRCUIT T = 12 HOUR TIMER WALL MOUNTED FOURPLEX RECEPTACLE OUTLET WALL MOUNTED VOICE/DATA PORT - (2) VOICE/(2) DATA IN SINGLE GANG BOX, UON OCCUPANT SENSING AUTOMATIC CONTROL © NEW CARDREADER, GC TO PROVIDE POWER PATH AND PULL STRING G?0,2 ?0,,g FLOOR MOUNTED OUTLET, UON: FLUSH DUPLEX RECEPTACLE OUTLET AND DATA OUTLET - (1) VOICE/(1) DATA IN SINGLE GANG BOX, UON FLEXIBLE CONDUIT WHIP/BASE POWER INFEED TO ATTACH TO FURNITURE SYSTEM, THROUGH WALL - POWER, DATA & VOICE FLOOR MOUNTED OUTLET, UON: FLUSH DUPLEX RECEPTACLE OUTLET AND DATA OUTLET WITH FLEXIBLE CONDUIT WHIP/BASE POWER INFEED TO ATTACH TO FURNITURE SYSTEM - POWER, DATA & VOICE THERMOSTAT NEW LIGHT SWITCH: T = SWITCH ON TIMER, D = SWITCH ON DIMMER KEY NOTES: O 1. NEW STOREFRONT SYSTEM AND ACCESSIBLE ENTRY DOOR 2. FLOOR FINISH TRANSITION; WOM TO BE FINISH WITH CARPET. 3. NEW PLASTIC LAMINATE COUNTERTOP, BASE & UPPER CABINETS WITH SINGLE COMPARTMENT, TOP MOUNT SINK. 4. PROVIDE WATER SUPPLY LINE FOR NEW (F010) PLUMBED HOT/COLD WATER DISPENSER, 1/4" COPPER TUBES BELOW COUNTER. 5. PROVIDE WATER SUPPLY. LINE TO (F010) REFRIGERATORS, 1/4" COPPER TUBES BELOW COUNTER. 6. PROVIDE WATER SUPPLY UNE TO (F010) COFFEE MAKER, 1/4" COPPER TUBES BELOW COUNTER. 7. NEW 4'X8'X3/4" TYPE 'X'/FIRE RESISTANT PLYWOOD BACKBOARD ON WAI I S AS INDICATED, PAINTED TO MATCH WALL COLOR WITH FINISHED EDGES FOR TENANTS TELEPHONE AND SECURITY EQUIPMENT, TOP OF BACKBOARD MOUNTED AT CEILING, BOTTOM TO BE 26" AFF, MINIMUM. 2505 Third Avenue Suite 324 Seattle. WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com I .45 0 CI) 111111111111111.1111 9+000 co U W 0 LL 0 W CO CNI 5 m Er 0 w 0 uJ CO X 03 TUKWILA, WASHINGTON LILT ,.�.. REVIEWED FOR CODE COMPLIANCE I • APPROVED APR 112019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 05 2019. PERMIT CENTER Submittals/Revisions: FOR PERMIT 11/02/18 Sheet Title: FLOOR AND POWER PLANS Date: 10/31/18 Design: Drawn: Project No: Approved: Building No: 18-164.06 KCR Sheet No: COPYRIGHT CRAFT ARCHITECTS 2018