HomeMy WebLinkAboutPermit PG19-0069 - SHASTA BEVERAGES / MAINTENANCE SHOP - ADD COMPRESSED AIR TO HOSE REELS AND EQUIPMENTSHASTA BEVERAGE INC
MAINT. SHOP
1227 ANDOVER PARK E.
FINALED
12/4/2020
PGI 9-0069
Parcel No:
Address:
Project Name:
�=^�xx ^���^nn�"°v^U
n�U= «�u Tukwila
�
Department of Community Development
G3OOSuuthcente,Boulevard, Suite 0100
Tukwila, Washington 9UlQ8
Phmne:206'431-B670
Inspection Request Line: 206-430'9350
Web site: http://wmnw.TukmUoVVw.mox
PLUMBING/GAS PIPING PERMIT
3523049072
1227ANDOVEAPARK E
Permit Number:
Issue Date:
Permit Expires On:
SHASTA BEVERAGE, INC - MAINTENANCE SHOP
PGI9-OO69
5/13/2O19
11/9/2019
Contact Person:
Name:
Contractor:
Address:
License No:
Lender:
Name:
NATIONAL BEVERAGE CORP
8100SVV10THSTSTE4008.
PLANTATION, WA, 33324
DANDKEHLE
191GBONA|RDRSW, SEATTIEWA,
98116
AUBURN MECHANICAL INC
POBOX Z4S,AUBURN, WA, 98071
AUBURN111638A
'~'
Phone: (206)433-8997
Phone: (25])838-9780
Expiration Date: 9/12/2020
DESCRIPTION OFWORK:
INSTALL NEW COMPRESSED AIR TO HOSE REELS AND EQUIPMENT PER PLAN.
Valuation ofWork: $0\000.00
Water District: TUKWILA
Sewer District: TUKWILA
Fees Collected: $252.35
Current Codes adopted by the City of Tukwila:
international Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
VVACities Electrical Code:
VVA[29G46B:
VVAState Energy Code:
2017
20172017
2015
Permit Center Authorized Signature:
--\~�—/
Date: �� ` ~' /-/
I hearby certify that I have read and examined this permit and know the same to be true and correct, All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting nfthis permit does not presume tugive authority toviolate orcancel the provisions ofany other
state orlocal laws regulating construction urthe performance ofwork. |vmauthorized tosign and obtain this
development permit and agree tuthe conditions attached tothis permit.
Signat e�
.\
Print Name:
This permit shall become null and void ifthe work isnot commenced within 180days for the date nfissuance, orif
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
z: All permits, inspection records and applicable plans shall bemaintained at the job and available uothe
plumbing inspector.
2: All plumbing and gas vipingsystems shall be installed incompliance with the Uniform Plumbing Code and
the Fuel Gas Code.
3: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
4: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall beconducted inthe presence ufthe Plumbing Inspector. It shall bpthe duty uf
the holder ofthe permit tomake sure that the work will stand the test prescribed before giving notification
that the work isready for inspection.
5: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall beprotected
inaccordance with the requirements ofthe building code.
6: The issuance ofapermit orapproval nfplans and specifications shall not beconstrued tnbeapermit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code nrany other
ordinance ofthe jurisdiction.
7: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206)438'93S0
1900 PLUMBING FINAL
9002 ROUGH -IN GAS PIPING
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Gas Permit No. P& I q _cape(
Project No.
Date Application Accepted: 5-1--
Date Application Expires: L— 9
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address:
Tenant Name:
1227 Andover Park East
Shasta Beverage Inc. Maintenance Shop
King Co Assessor's Tax No.: 352304-9072
Suite Number: Floor:
PROPERTY OWNER
Name: Shasta Beverage Inc.
Address: 1227 Andover Park East
City: Tukwila State: WA
Zip: 98188
CONTACT PERSON — person receiving all project
communication
Name: David Kehle
Address: 1916 Bonair Drive SW
City: Seattle State: WA Zip: 98116
Phone: (206) 433-8997 Fax: (206) 246-8369
Email: dkehle@dkehlearch.com
New Tenant: 1 1 Yes
1
..No
PLUMBING CONTRACTOR INFORMATION
Company Name: Auburn Mechanical
Address: PO Box 249
City: Auburn State: WA Zip: 98701
Phone-
' (253) 838-9780 Fax:
Contr Reg No.: AUBURM I 163BA Exp Date: 09
2/2020
Tukwila Business License No: BUS-0994349
Valuation of Project (contractor's bid price): $ 80,000
Scope of Work (please provide detailed information):
Install new compressed air to hose reels and equipment per plan.
Building Use (per Int'l Building Code): Factory
Occupancy (per lnt'l Building Code): Fl B
Utility Purveyor: Water: Tukwila Sewer: Tukwila
HAApplicasiortsWorrns-Applications �n Line1.2011 Applications \ Plumbing Permit Application Revised /1-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
ConraegAtio
r2709
-4
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no perrnit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW ORIZED AGENT:
Signature:
Print Name: David Kehle
Mailing Address: 1916 Bonair Drive S.W.
Date: 05/02/2019
Day Telephone: (206) 433-8997
Seattle WA 98116
City State Zip
11:1ApplicationsWoran-Applications On Line \ 2011 Applications \ Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT QUANTITY
PermitTRAK
PAID
$202.65
PG19-0069 Address: 1227 ANDOVER PARK E Apn: 3523049072 $202.65
PLUMBING $193.00
PERMIT FEE
R000.322.100.00.00
0.00
$158.00
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$35.00
TECHNOLOGY FEE $9.65
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R17607
R000.322.900.04.00
0.00
$9,65
$202.65
111111111010.11111.1111
Date Paid: Wednesday, May 08, 2019
Paid By: SHASTA BEVERAGES
Pay Method: CHECK 598081
Printed: Wednesday, May 08, 2019 11:47 AM 1 of 1
Y TEM5
Cash Register Rece
City of Tukwila
DESCRIPTIONS
ACCOUNT
QUANTITY
PAID
PerrnitTRAK
$148.97
EL19-0390 Address: 1227 ANDOVER PARK E
Apn: 3523049072
$99.27
Credit Card Fee
$2.89
Credit Card Fee
R000.369.908.00.00
0.00
$2.89
ELECTRICAL
$96.38
PLAN CHECK FEE
R000.345.832,00.00
0.00
$96.38
PG19-0069 Address: 1227 ANDOVER PARK E
Apn: 3523049072
$49.70
Credit Card Fee
$1.45
Credit Card Fee
R000.369.908.00.00
0.00
$1.45
PLUMBING
$48.25
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R17565
R000.322.103.00.00
0.00
$48,25
$148.97
Date Paid: Thursday, May 02, 2019
Paid By: NICHOLAS HEATON
Pay Method: CREDIT CARD 002814
Printed: Thursday, May 02, 2019 11:59 AM 1 of 1
CO TUKWILA FTRAKIT
azon SouT*cENTsn uLvo
TUKWILA, WA 98188
206'433'1870
CITY OF TUKWILx
0017340000802374464500
Date: 05/02/2819 11:59:24 my
[KcozT Cxno SALE
VISA
Cxno wuMocn: ^***^*°**9037 x
TR4N AMOUNT: $148.97
APpnVvxL [o: 002814
os[Ono #: 080
CLERK In: kandace
X
{CARDHOLDER'S SIGNATURE)
I AGREE TO PAY THE ABOVE TOTAL AMOUNT
ACCORDING TO THE CARD ISSUER AGREEMENT
(MERCHANT AGREEMENT IF CREDIT VOUCHER)
Thank you!
Merchant Copy
Permit Number: PG19-0069
Applied: 5/2/2019 Approved: 5/10/2019
Issued: 5/13/2019 Finaled: 12/4/2020
Status: FINALED
Parent Permit:
Parent Project:
Details:
Description: SHASTA BEVERAGES, INC MAINTENANCE SHOP
Site Address: 1227 ANDOVER PARK E
City, State Zip Code:TUKWILA, WA 98188
Applicant: SHASTA BEVERAGES, INC - MAINTENANCE SHOP
Owner: NATIONAL BEVERAGE CORP
Contractor: AUBURN MECHANICAL INC
INSTALL NEW COMPRESSED AIR TO HOSE REELS AND EQUIPMENT PER PLAN.
i ' IRg' 0 S
SCHEDULED DATE
COMPLETED DATE
TYPE
INSPECTOR
RESULT
REMARKS
ROUGH -IN
PLUMBING
Lee Sipe
NOT APPROVED
Air line at shop mezzanine
Notes:
All air line supports need seismic bracing.
ROUGH -IN
PLUMBING
Lee Sipe
NOT APPROVED
Air line at shop mezzanine
Notes:
1. All air line need seismic bracing.
2. All air lines need labeled for identification.
3. Air lines for shop mezzanine need isolation, copper frorn galv. steel brackets.
ROUGH -IN
PLUMBING
Lee Sipe
APPROVED
Air line at shop mezzanine
Notes:
5/17/2019
5/20/2019
ROUGH -IN
PLUMBING
Lee Sipe
NOT APPROVED
Notes:
NOT ready
No plans or permits available for inspection.
Reschedule.
6/10/2019
6/11/2019
ROUGH -IN
PLUMBING
Lee Sipe
PARTIAL
APPROVAL
Notes:
2 P/A
Workshop and Mezzanine.
Air lines for shop mezzanine need isolation, copper from galv. steel brackets.
11/17/2020 AM
11/17/2020
PLUMBING FINAL
Lee Sipe
NOT APPROVED
air lines at machine shop
Notes:
1. All air line need seismic bracing.
2. All air lines need labeled for identification.
3. Air lines for shop mezzanine need isolation, copper from galv, steel brackets.
Printed: Thursday, 17 August, 2023
1 of 2
p-1
SUPERION
12/2/2020
12/2/2020
ROUGH -IN
PLUMBING
Bill Centen
NOT APPROVED
- Air line at shop mezzanine
Notes:
1. All air line need seismic bracing.
2. All air lines need labeled for identification.
3. Air lines for shop mezzanine need isolation, copper from galv. steel brackets.
12/4/2020 PM
12/4/2020
I PLUMBING FINAL
Lee Sipe
APPROVED
Lee Ranton 206-681-5198
Notes:
Printed: Thursday, 17 August, 2023 2 of 2
rik
SUPERION
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development- Jack Pace, Director
October 25, 2019
David Kehle
1916 Bonair Dr SW
Seattle, WA 98116
RE: Request for Extension #1
Permit Number PG19-0069
Dear Mr. Kehle,
This letter is in response to your written request for an extension to Permit PG19-0069. The Building
Official, Jerry Hight, has reviewed your letter and considered your request to extend the above
referenced permit. It has been determined that the City of Tukwila Building Division will be granting an
extension to the permits through May 9, 2020.
If you should have any questions, please contact our office at (206) 431-3670.
Sincerely,
Rachelle Ripley
Permit Coordinator
File: Permit No. PG19-0069
Tukwila City Hall • 6200 Southcenter Boulevard Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
david
kehle
architect
October 10, 2019
ANIL
Request f\iExtensior #
Current Expiration Date:
Extension Request:
XApproved for
f
{i Denied (providc cxpInation
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
Attn:
RE:
Mr. Jerry Hight
Shasta Beverage Inc,
1227 Andover Park E
Tukwila, WA 98118
Tenant Improvement
Maintenance Shop
PG19-0069
Dear Mr. Hight,
days
Signature:nitials
RECEIVED
CITY OF TUKWILA
OCT 1 1 2019
PERMIT CENTER
As the Design Professional In Responsible Charge, I am requesting an extension for the
above permit based on the following:
1. There are several sequential items that need to take place before other permitted
projects can proceed. Timing is causing delays for some construction and final
inspections.
2. There are on going reviews of some projects (Glycol Room, and revised
drawings for Breakroom and QA lab) that have been submitted to the city
3. There are on going reviews of the projects waiting for our responses or city
reviews.
4. We have been working with Lee on several of the permits and inspection
processes.
For the above reasons, I am requesting the permit be extended. If you have any
questions, please let me know.
David Kehie
1916 Bonair Drive S.W.
Seattle, WA 98116
(206) 433-8997
fax (206) 246-8369
email: dkehle@dkehlearch.com
0
City of Tukwila
Department of Community Development
10/1/2019
DAVID KEHLE
1916 BONAIR DR SW
SEATTLE, WA 98116
RE: Permit No. PG 19-0069
SHASTA BEVERAGES, INC - MAINTENANCE SHOP
1227 ANDOVER PARK E
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 11/9/2019.
Based on the above, you are hereby advised to:
1) CaII the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 11/9/2019, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: PG19-0069
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
os.)
COORD COP'(
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG19-0069
DATE: 05/02/19
PROJECT NAME: SHASTA BEVERAGE, INC - MAINTENANCE SHOP
SITE ADDRESS: 1227 ANDOVER PARK E
X Original Plan Submittal
Response to Correction Letter # Revision # after Permit Issued
Revision # before Permit Issued
DEPARTMENTS:
!1M Min v sioni
VO N R '5
Public Works
1
Fire Prevention
Structural
Planning Division
Permit Coordinator Si
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
REVIEWER'S INITIALS:
11111111111111111•0111111111111111111111111111111111111111111111111111n
APPROVALS OR CORRECTIONS:
DATE: 05/07/19
Structural Review Required
DATE:
DUE DATE: 06/04/19
Approved Approved with Conditions ri
Corrections Required
(corrections entered in Reviews
Denied
(ie: Zoning Issues
r
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MA ED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
12/18/2013
Home 'Espanol Contact
tt-Attre,
Safety & Health Claims & Insurance
kWashington State Department of
)Labor & Industries
A-Z Index Help My
Workplace Rights Trades & Licensing
AUBURN MECHANICAL INC
Owner or tradesperson
Principals
THODAY, DAVID V, PRESIDENT
JOHNSON, STACY ANNE, PRESIDENT
JOHNSON, KIM PAUL, SECRETARY
Doing business as
AUBURN MECHANICAL INC
WA UBI No.
600 074 968
PO BOX 249
AUBURN, WA 98071
253-838-9780
KING County
Business type
Corporation
Governing persons
STACY
A
JOHNSON
KIM JOHNSON;
RYAN HOWARD MCMAHAN;
[License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
AUBURMI163BA
Effective — expiration
01/01/1984— 09/12/2020
Bond
Travelers Cas and Surety Co of America
Bond account no.
106958648
$12,000.00
Received by L&I Effective date
09/24/2018 10/0112018
Expiration date
Until Canceled
Bond history
Insurance
....
Continental Insurance Co $1,000,000.00
Policy no.
6072614904
Received by L&I Effective date
09/28/2018 10/01/2018
Expiration date
10/01/2019
Insurance history Help us improve
J
A
B
C
D
E
F
G
H
J
K
2
3
4
6
7
8
9
10
WORK LOCATION
VICINITY MAP
NO SCALE
NORTH
Ja
TRILAND DR
W
0
0
Z
WORK LOCATION
SITE PLAN
ANDOVER PARK E
COSTCO DR
NO SCALE
A
C
NORTH
WORK LOCATION
AERIAL PLAN
NO SCALE
GENERAL NOTES:
MECHANICAL, GENERAL
1. CODE COMPLIANCE - ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND
ORDINANCES.
2. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL ARRANGEMENT OF
THE CONSTRUCTION AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS,
FITTINGS, AND ACCESSORIES WHICH ARE REQUIRED.
3. FIELD VERIFICATION: CHECK FIELD CONDITIONS AND VERIFY SPACE AVAILABLE FOR
DUCTS BEFORE PROCEEDING WITH THE WORK (IF EXISTING BLDG, OR DURING
CONSTRUCTION OF NEW.
4. WARRANTY: ALL WORK AND EQUIPMENT SHALL BE WARRANTED TO BE FREE FROM
DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD
OF 1 YEAR AFTER FINAL ACCEPTANCE.
5. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM THE WORK
REQUIRED ARE SPECIFIED OR SHOWN. CONTRACTOR SHALL PROVIDE ALL ITEMS
NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS. ITEMS PROVIDED
SHALL BE OF COMMERCIAUINSTITUTIONAL QUALITY CONSISTENT WITH THE QUALITY
OF RELATED ITEMS PROVIDED ON THE PROJECTOR CURRENTLY BEING USED IN THE
BUILDING.
6. SEISMIC: ALL PIPING SHALL BE BRACED FOR SEISMIC CATEGORY FOR THIS PROJECT
PER CODE AND SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR
MECHANICAL SYSTEMS" LATEST EDITION. BUILDING IS NON -ESSENTIAL, SEISMIC
CATEGORY "D".
7. ALL INSTALLED PIPING AS INDICATED ON DWG MP0.1 SHALL BE IN COMPLIANCE WITH
ALL REQUIREMENTS INDICATED ON THIS SHEET.
PIPE AND PIPE FITTINGS
1. ALL PIPE SHALL BE COPPER TUBE, TYPE "L", RATED FOR A MINIMUM OF 100 PSI. ALL
FITTINGS SHALL BE SWEAT TYPE.
2. AIR PIPING SHALL BE LEAK TESTED @ 1.5 TIMES THE OPERATING PRESSURE FOR 2
HOURS OF NO LEAKS.
HANGERS AND SUPPORTS
1. BALL VALES: NIBCO S580. T580, OR EQUAL, OR OWNER PREFERANCE.
2. INSTALLATION: INSTALL VALVES WITH STEM VERTICAL AND HANDLE UP WHEREVER
POSSIBLE; IN NO CASE BELOW HORIZONTAL. INSTALL IN LOCATION FOR EASE OF
ACCESS. INSTALL ALL VALVES IN STRICT ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS; SAFETY VALVES SHALL HAVE FULL SIZE INLET AND OUTLET
CONNECTIONS.
2015 IMC CODE COMPLIANCE
1. ALL PIPING, VERTICAL AS WELL AS HORIZONTAL PIPING INSTALLATION, SHALL BE IN
ACCORDANCE W/ SECTION 305, 305.1 THROUGH 305.4, AND TABLE 305.4 "PIPING
SUPPORT BRACING".
D
E
NORTH
F
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
MECHANICAL / PIPING LEGEND
SYMBOL
DESCRIPTION
ABBREV.
DESCRIPTION
ISOLATION VALVE (SEE SPECIFICATIONS OR NOTE ON DWG FOR TYPE)
A
AFF
APPROX
ARCH
AUTO
BTU
BTUH
BLDG
C
CAP
CLG
CO
CONN
CONT
CW
DCVA
DEG F, F°
DIA, 0
DIM
DN
DWG
EA
EFF
ELEC
EXIST, (E)
ESP
FD
FV
FPM
FLEX
FL
FCC
FLA
FOIC
GAL
GALV.
GI
HW
INTEGR.
IN
I.E.
KW
MFR
MAX
MECH
NIC
MIN
NO
NC
COMPRESSED AIR
ABOVE FINISHED FLOOR
APPROXIMATELY
ARCHITECTURAL
AUTOMATIC
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT/HOUR
BUILDING
CONDENSATE
CAPACITY
CEILING
CLEANOUT
CONNECTION
CONTINUE, CONTINUATION
COLD WATER
DOUBLE CHECK VALVE ASSEMBLY
DEGREE FAHRENHEIT
DIAMETER
DIMENSIONS
DOWN
DRAWING
EACH
EFFICIENCY
ELECTRICAL, ELECTRIC
EXISTING
EXTERNAL STATIC PRESSURE
FOOTING DRAIN
FACE VELOCITY
FEET PER MINUTE
FLEXIBLE
FLOOR
FLOOR CLEAN OUT
FULL LOAD AMPS
FURNISHED BY OWNER
GALLON
GALVANIZED
GREASE INTERCEPTOR
HOT WATER
INTEGRAL
INCH
INVERT ELEVATION
KILOWATT
MANUFACTURER
MAXIMUM
MECHANICAL
NOT IN CONTRACT
MINIMUM
NORMALLY OPEN
NORMALLY CLOSED
NUMBER
NOT TO SCALE
OPPOSITE
PHASE
PRESSURE DROP
REFERENCE
REQUIRED
RATED LOAD AMPS
REVOLUTIONS PER MINUTE
ROOM
SURFACE CLEANOUT
TEMPERATURE
TYPICAL
UNLESS NOTED OTHERWISE
VENTED THROUGH ROOF
VOLTS, VOLTAGE, VENT
WALL CLEANOUT
WASTE
WATT
WITH
{Xj
CHECK VALVE
—IN-4--
OS&Y VALVE
1:1
UNION
Q
RELIEF VALVE OR SAFETY VALVE
9 J
STRAINER (W/ BLOWDOWN VALVE)
+� I
CONCRETE REDUCER
Q
PRESSURE GAUGE
COMPRESSED AIR LINE
A
NO.
NTS
OPP
PH
PD
REF
REQ'D
RLA
RPM
RM
SCO
TEMP
TYP
UNO
2
DETAIL IDENTIFICATION NUMBER
- SHEET ON WHICH DETAIL IS SHOWN
VTR
V
WCO
W
,
M3
SECTION IDENTIFICATION LETTER
SHEET ON WHICH SECTION IS SHOWN
WA
W/
® /—
DISCLAIMER - QUALIFIER:
ENGINEER HEREIN AND CONTRACTOR SHALL NOT ASSUME ANY RESPONSIBILITY
FOR THE CORRECT OPERATION OF ANY OF THE EQUIPMENT INDICATED IN THIS
SCOPE OF WORK DUE TO MANUFACTURER'S CERTIFIED DRAWINGS OR
TERMINATIONS, ETC, CUT SHEETS, OPERATIONAL MANUALS AND / OR TECHNICAL
INFORMATION NECESSARY FOR ANY COMPLETE COMPRESSED AIR SYSTEM
DESIGN, BY NOT BEING AVAILABLE DURING THE DESIGN OF THE PIPING SYSTEMS
FO R THE EQUIPMENT HEREIN.
HOWEVER, ALL GOVERNING CODES HAVE BEEN ADDRESSED IN THE CONTRACT
DOCUMENTS NECESSARY FOR CONSTRUCTION THEREFORE COMPLYING WITH
THE AFOREMENTIONED CODES, I.E., 2015 IMC, EARTHQUAKE AND SEISMIC CODES
INCLUDING SMACNA STANDARDS COMPLIANCE, NECESSARY FOR PROPER
CONSTRUCTION OF ITEMS TO BE INSTALLED PER THE PLANS.
DRAWING INDEX
MP0.0 MECHANICAL LEGEND & NOTES
MP0.1 MAINTENANCE SHOP AIR PIPING
MP0.2 DETAIL ELEVATION VIEWS
G
OT E:'";;:'esn t
H
RECEl'' EU
CITY OF TUKWILA
MAY 0 2 2019
PERMIT CENTER
1)15 Iq- bo(pci
J
CODE COMPLIANCE
APPROVED
ity of Tukwila
BUILDING DIVISION
RENEW: 8/16/2020
2
PERMIT SET
K
3
4
5
6
7
8
9
0
NG PLANT
SHEET TITLE: MECHANICAL LEGEND & NOTES
PROJECT MANAGER: MR. KEVIN HAYES
NN
N r
� W
J V 4:00
2 tx
aNka
I0r"
C1mZWF
WWW -J
20Y04
CHECKED: JPE
U
2623 WEST VALLEY HWY N AUBURN, WA 98001
1-
co
w
ce a
a�'rn
LLI co
O Y c
ZI'�
r`
N
PROJECT NO.: EC-19-011
DATE: 4-12-19
P.O. NUMBER: 6517
FIVE STAR MECHANICAL, INC.
MP0.0
B
A
B
D
E
F
H
J
K
L
2
3
4
5
6
7
8
9
10
1"0
1 /2"0
AIR PIPING PLAN
1"0
1"0
1"0
1
MPO.'MPO.2
1 /2"0
(E) MAINTENANCE
(BELOW (E) MEZZANINE METAL FLOOR)
A
MPO.'MP0.1
SEE DETAIL #3, SHEET MP0.2 - FOR
TOP CONNECTION TO CEILING (TYP)
1"0
OFFICE
1011
OFFICE
11021
(E) VERTICAL
COLUMNS (TYP)
SEE DETAIL #3,
SHEET MP0.2 (TYP)
SCALE: APPROX. 1/4" =
NORTH
DRAWING NOTES
0 (E) 2" DIA. COPPER AIR LINE UP TO ABOVE MEZZANINE.
0 (E) 1" DIA. AIR SUPPLY LINE, TIGHT TO CEILING (SUPPORT PER SMACNA
STANDARDS AND SEISMIC BRACE LOCAL CODES.) TO SERVICE - HOSE
REELS IN OTHER AREAS.
11
(E) VERTICAL AIR RECEIVER TANK (REF) SUPPLYING 105 PSI AIR TO (E) AIR
LINES (REF) PER OWNER.
(E)1" DIA. COPPER AIR LINE SUPPORTED APPROX. 18" FROM METAL CEILING .
SEISMIC BRACE PER LOCAL CODES. SEE SHEET MP0.2
CONNECT'/2" AIR SUPPLY LINE TO NEW HOSE REEL INSTALLED BELOW
CEILING ON COLUMN.
SUPPORT %" DIA. COPPER AIR LINE AT ELBOW 4" PRIOR TO CONNECTION OF
HOSE REEL.
MAINTENANCE SHOP CEILING IS FLOOR OF MEZZANINE ABOVE. ALL PIPING
IS SUPPORTED FROM METAL CEILING OF MAINTENANCE SHOP.
(E) METAL BEAM — REFERENCE
(E) AIR HANDLERS ABOVE AND NOT IN SHOP (REFERENCE ONLY)
CONNECT'/2" AIR SUPPLY LINE TO NEW HOSE REEL INSTALLED BELOW
CEILING ON COLUMN. SUPPORT 1/2" DIA. COPPER AIR LINE AT ELBOW 4"
PRIOR TO CONNECTION OF HOSE REEL.
(E) CHAINLINK WALL THAT DELINEATES THE BOUNDARYS OF THE
MAINTENANCE SHOP — REF.
(E) SLIDING VEHICLE GATE. HAND OPERATED.
(E) CHAINLINK LOCKABLE MAN DOOR — REF ONLY.
2
3
4
NOTE: ENGINEER ONLY WARRANTS ADDITIONAL WORK ON THE EXISTING COPPER 5
AIR LINE COMPRESSED AIR SYSTEM FOR HOSE REELS. ENGINEER DOES NOT
WARRANT OPERATION OF THE (E) AIRLINES AS SHOWN, BUT SUPPORTS PER SMACNA
STANDARDS ONLY.
NOTE: AIR LINE DISTRIBUTION SHOWN HERIN IS AS -BUILT.
(E) MAINTENANCE
SHOP CEILING (REF) J
(E) MEZZANINE
FLOOR (METAL)
SEE SHEET MP0.2
(DETAIL #2)
NEW SEISMIC BRACING
TO MAINTENANCE I (10' - O.C.)(TYP)
SHOP FLOOR LEVEL
ELEVATION
riECEIVHD
CITY OF T UKW1L,=
MAY 022019
PERMIT CENTER
REVIEi.`°sfD FOR
(E) 1" AIR SUPPLY PIPING CODE COMPLIANCE
(COPPER) (SEE DETAIL #3, APPROVED
SHEET MP0.2) (TYP)
NO SCALE
f'61100(009
•t.'iA 1. `.' LvfJ
City of Tukwila
BUILDING DIVISION
NP0.1
RENEW: 8/16/2020
6
7
8
9
0
O
NG PLANT
SHASTA BEVERAGES CANN
SHEET TITLE: MAINTENANCE SHOP AIR PIPING
PROJECT MANAGER: MR. KEVIN HAYES
0
b r
rm
JJpA
cc
a `M
< z
x 0 U 47
in' 2W1-
WWW-J
X0Y04
CHECKED: JPE
PROJECT NO.: EC-19-011
DATE: 4-12-19
P.O. NUMBER: 6517
N AUBURN, WA 98001
3 WEST VALLE
FIVE STAR MECHANICAL, INC
MPO.1
—1 A
B
D
E
F
H
J
PERMIT SET
A
B
D
E
F
H
J
K -
1
2
3
4
5
6
7
8
9
10
FIGURE 4-15 ALTERNATE ATTACHMENT TO HANGER FOR PIPE BRACING
"J" HANGER
Z Z
0 1. 0
Z "
0
M—I r-r,X
P z
0 m
w
z `,1
L-.)
c
=Ix
•
INSTALL BENT t FOR
LONGITUDINAL BRACE
AT THIS POINT,
CONNECTION TYPE
-c1•-\_ A THRU D BENT I
3"x1/4"
E THRU H BENT
\ \ 4"x3/8"
\ , \
LI*1 \
1.\N
--=,\__<"c",1•>>21, J FELT PAD OR
I ISOLATION IF REQUIRED
TRANSVERSE BRACE
DETAIL ELEVATION
SMACNA STANDARDS
GALV. HOLD-DOWN WIRE FOR
GLASS PIPE ONLY.
I 1 MIN
2 MAX
ADJUSTABLE SOLID
OR SPLIT RING
HANGER
\e'
TRANSVERSE BRACE
FIGURE 4-13 TRANSVERSE BRACING FOR PIPES
CONNECT ON TO SUPPORTING
STRUCTURAL MEMBER
!EXPANSION ANCHORc-, SHOWN .
HIERE FOR EX/WEI...E. / 1•5!
rTh
MPO. PO.2
/ 1 AL -ERN
TRANSVERSE BRACE
2 VAX
1 MIN •
.iIPL • IANGLIi
:?()D CuIP
CONNLC 11',13N I vI2.-
A T-RU D BENT
rx1
r, /6.2 x 6.4
THRU H 6EN
(11 . 6 x 9 . r-')
DETAIL ELEVATION
1/8" - 2'4"
3 7, (25G. -609 rn)
ADD VERTICAL 1 ANOE'RS POv
SCH6DULE WHIEI',1 'L' GR7 ,A, TER
AD!) PIPF SI 1-.F. VF (HA I
HAS AN, INSIDE DIA.VETER,
1 /4- (I3.4 rr m 1 - ARE7R.
'HAN CI, I112•L
DIAVTITER ar
PIPF HANCIFR
r-
SMACNA STANDARDS
MPO. WO.2
FIGURE 4-16 LONGITUDINAL BRACING FOR PIPES
LUOJ1tL»AL BRA C1.1
IC) 60s/h. WEA
AVY 1-4 C4FvF.
•
AD1 V1_1(1'CA. HANCi. (
SCF1FFA, F
• GR-AiFR IHA\1 1,1ACIMG',!
_I 11, 6 •
mr6)
I
F 1
WELDEL; 17.7. AM
A 1. AO -WEN
6/16
\
I .;•11 I -
••! "
1."„ '
DETAIL ELEVATION - CORNERS & 90° TURNS SUPPORT (S)
SMACNA STANDARDS MP0NP0.2
P6119 100111
. .
R1iVII':"V•i!;:]p I.' OR I
CODE COMPLIANCE I
APPROVED
''."11 1 `11'•'1Q
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAY 0 2 2019
PERMIT CENTER
RENEW: 8/16/2020
2
3
4
5
6
7
8
9
0.
SHASTA BEVERAGES CANNING PLANT
SHEET TITLE: DETAIL ELEVATION VIEWS
tO
N
uJ
• CA
U) 1--
(/)
>"
(/)
<
.47 CL -
rz 5 c?
• < l>1
Lu z 0
CO• W cy,
wz
• Z
2 2 -
0
PROJECT MANAGER: MR. KEVIN HAYES
CHECKED: JPE
w
PROJECT NO.: EC-19-011
DATE: 4-12-19
P.O. NUMBER: 6517
FIVE STAR MECHANICAL, INC.
MP0.2
—1 A
B
c
D
E
F
H
J
PERMIT SET