Loading...
HomeMy WebLinkAboutPermit PG19-0076 - MORPHE - NEW LAVATORY, WATER CLOSET, MOP SINK, DRINKING FOUNTAIN, WATER HEATER AND FLOOR DRAINMORPHE 637 SOUTHCENTER MALL PGI9-0076 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 9202470010 637 SOUTHCENTER MALL Project Name: MORPHE Permit Number: PG19-0076 Issue Date: 8/20/2019 Permit Expires On: 2/16/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, MN, 92013 TIM SCHENK 1120 E 80 ST #211 , BLOOMINGTON, MN, 55420 TRAINOR COMMERCIAL CONST INC 1925 FRANCISCO BLVD E #21 ATTN: SABRINA REYNOLDS, SAN ANSELMO, CA, 94901 TRAINCC950LW Phone: (952) 345-6040 Phone: (415) 259-0200 Expiration Date: 4/26/2021 DESCRIPTION OF WORK: REMODEL OF AN EXSITING RETAIL TENANT SPACE IN THE MALL FOR A NEW MORPHE STORE. NEW LAVATORY, WATER CLOSET, MOP SINK, HI/LO DRINKING FOUTAIN, WATER HEATER & FLOOR DRAIN Valuation of Work: $20,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $289.90 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating truct. n or the performance of work. I am authorized to sign and obtain this development per ar r to th ions attached to this permit. Signature: Print N e: von^ eeitiry2 Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No.T6 q— 007 (0 Project No. Date Application Accepted: Date Application Expires: (For o lee use on! PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 631 SO'Jfl4CW1ER. MAU— Tenant Name: M Of-494e PROPERTY OWNER Name: svita— Address: 4ActOS a..0 Onr-A-AATZ.0 Cer1M.1 06C1 City: SKOK i E State: IL. Zip:on CONTACT PERSON — person receiving all project communication Name: Tim saber/K. Address:1114 e . so 4creieer . 5,4 ye_ it 1 City: auunirfGror4 State: Int( Zipss4212 Phone:ci-y.14 c .6q4Q, Fax:1s2.154.49Ais Email: sivts e ecrAer, j dines . co 0.... King Co Assessor's Tax No.: noz,4700[0 Suite Number: I SSO Floor: i New Tenant: Er Yes 0 ..No PLUMBING CONTRACTOR INFORMATION Company Name: T. a Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ Z4.0124 Scope of Work (please provide detailed information): FF—MOOELC3F- 6,4 exk5 ri r4G. (ZECAlt— mattiVR.srele0 NEW LAot ,ViAtZte-LOSe i&c:171132.14 OnAs4 . Building Use (per Intl Building Code): tri..f 51 vPOE iri 111E platILS- MO. A N 14;(L D(Lirw 4J7J, 141r VAASA- titacralcit.e gercitcsak.e.s- Occupancy (per Int'I Building Code): IA Utility Purveyor: Water: 14046(tvx Sewer: 144MLA HAApplications \ Forms -Applications On Line \ 2011 ApplicationsTlumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 rib) Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 0116,51 rm. Rain water system - per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (I -5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment ackflow protective dcvie other than atmospheric - type vacuum breakers 2 ineh (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food-wastc grindcr, commercial Wash fountain Water closet industrial waste treatment interceptor, including trap and vent, except for kitchcn type grease interceptors Repair or alteration of drainage or vent piping Backtlow protective device other than atmospheric -type vacuum breakers over 2 inch (51 ram) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ADrED AGENT: Signature: Date: 51zIffq Print Name: -Tin\ sctieriK Day Telephone: (IS a 0345%6040 Mailing Address: It13E #€10 sittEer, su‘sE zli aLlxinurg.rerti 011.4 sscizo City State Zip R\ApplicationsWorms-Applications On Line12011 Applications \Plumbing Permit Application Revised 8-9-11.docx Revisccb August 2011 bh Page 2 of 2 Cash Rqister Receipt City of Tukwila Receipt Number DESCRIPTIONS ACCOUNT QUANTITY !, PAID . .. . PermitTRAK $6,577.33 D19-0173 Address: 637 SOUTHCENTER MIALL Apn: 9202470010 $3,919.80 DEVELOPMENT $3,734.33 PERMIT FEE R000.322.100.00.00 0.00 $3,709.33 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $185,47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $185.47 D19-0174 Address: 637 SOUTHCENTER MALL Apn: 9202470010 $331.61 DEVELOPMENT $317.01 PERMIT FEE R000.322.100.00.00 0.00 $292.01 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $14.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.60 EL19-0456 Address: 637 SOUTHCENTER MALL Apn: 9202470010 $1,394.12 ELECTRICAL $1,327.73 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,327.73 TECHNOLOGY FEE $66.39 TECHNOLOGY FEE R000.322.900.04.00 0.00 $66.39 M19-0090 Address: 637 SOUTHCENTER MALL Apn: 9202470010 697.65 MECHANICAL $664.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $631.28 TECHNOLOGY FEE $33.22 TECHNOLOGY FEE R000.322.900.04.00 0.00 $33.22 PG19-0076 Address: 637 SOUTHCENTER MALL Apn: 9202470010 234.15 PLUMBING $223.00 PERMIT FEE R000.322.100.00.00 0.00 $188.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $11.15 TECHNOLOGY FEE R000.322.900.04.00 0.00 $11.15 . , TOTAL FEES PAID BY RECEIPT: R18372 . 6 77.33 Date Paid: Tuesday, August 20, 2019 Paid By: TRAINOR COMMERCIAL CONSTRUCTIO Pay Method: CHECK 054538 Printed: Tuesday, August 20, 2019 10:08 AM 1 of 1 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,964.85 D19-0173 Address: 637 SOUTHCENTER MALL Apn: 9202470010 $2,411.06 DEVELOPMENT $2,411.06 PLAN CHECK FEE R000.345.830,00.00 0.00 $2,411.06 EL19-0456 Address: 637 SOUTHCENTER MALL Apn: 9202470010 $331.93 ELECTRICAL $331.93 PLAN CHECK FEE R000.345.832.00.00 0.00 $331.93 M19-0090 Address: 637 SOUTHCENTER MALL Apn: 9202470010 $166.11 MECHANICAL $166.11 PLAN CHECK FEE R000.322.102.00.00 0.00 $166.11 PG19-0076 Address: 637 SOUTHCENTER MALL Apn: 9202470010 $55.75 PLUMBING $55.75 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R17763 R000.322.103.00.00 0.00 $55.75 $2,964.85 Date Paid: Thursday, May 30, 2019 Paid By: ELDER JONES Pay Method: CHECK 81643 Printed: Thursday, May 30, 2019 3:12 PM 1 of 1 Y TEMS INSPECTION RECORD Retain a copy with permit 1 12I9 007 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro A • • Tess: Special Instructions: Ty e of Insp ction: vtir mate Called: Date 'kanted: a.m. p.m. =Requeste Phone No: proved per applicable codes. +Go 'rections re ' ror to approval. pector: REINSPECT'I©N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a ropy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prof t: Type of Inspection: Address: 673, Date Called: G0' _50 Special Instructions: Date Wanted: p.m. v Requester: Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. nspectoDate: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must ire paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectlon. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P&Ici-DG76 Project: ©tr'plc . Address: Special instruction CO COMMENTS nspecto e of Ins • ection. PLAwp T Date C Date Wa Requeste Phone No: Corrections required prior to approval. e:t0 ZW,' n REINSPECTION FEE REQUIRED. Prior to next inspe do fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 TG-Ict -oo70 Project: ... 4.-. Type of Inspection: G7RCNOAT,C) tok-JOAA. Address: ilkil-- Date Called: Special Instructions: Date Wanted: a.m. , p.m. Requester: (—I— ,)*.r4"/ Atirg17— Afrjrrofar4ver70729er../P5 /7471 .otiRee e/2$1,4A03,4fie Phone No: oz 4772-5-2,2_-% 20 proved per applicable codes. Corrections required prior to approval. COMMENTS: Z ,......:0/ i D Inspector: Date: aq.C-19 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0076 DATE: 05/30/19 PROJECT NAME: MORPHE SITE ADDRESS: 637 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 411ing Division (N3S Public Works Fire Prevention Structural Planning Division Permit Coordinator ti PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/04/19 Structural Review Required REVIEWER'S INIT ALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 07/02/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping EJ PW EJ Staff Initials: 12/18/2013 Non -Residential Sewer se Certification Sewage Treatment Cap ty Charge King County Department of Natural Resources and Parks Wastewater Treatment Division To be completed for all new sewer connections, reconnections or change of use of existing connections. Please Print or Type 6.1./c76L4 Property Street Address 0,6440 (4/7-6/1- City e.c/i</6. State / e_ ZIP Owner's Name Owner's Mailing Address City State ZIP Owner's Phone Number including Area Code PropeMr—Contact Number including Area Code 70-4 , /16 Party to be Bil ed (if differerAlrom owner) L"i zi Address City acr.1/A107-06( State ZIP A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 / Hose bibb (interior) 2.5 2.5 Clothes washer or laundry tub 4 2 Sink, bar or lavatory 2 1 I Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 / Sink, wash wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 / Water closet, tank or valve, >1.6 GPF 8 4 , Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1 0 RCE Total Fixture Units _ 20 RCE Property Tax ID # Subdivision Name Subdiv. # Lot # Block # Building Name (if applicable} City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre-existing structures on this property. Credit for a demolition may be given under some circumstances. (See King County Code 28.84.050, 0.5) Demolition of pre-existing structure? 0 Yes 0 No Was structure on Sanitary Sewer? 0 Yes 0 No Was Sewer connected before 2/1/90? zi Yes 0 No Sewer disconnect date Type of structure demolished Request to apply demolition credit to multiple structures? 0 Yes Ej No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) RECEIVED CITY OF TUKNVII) Estimated Wastewater Discharge: g0 2019 Gallons/days Residential Customer Equivalents (RPERMIT CENTEr Type of Facility/Process: 187 gallons per day equals 1.0 RCE Total Discharge (gaVday) _ 187 RCE C. Total Residential Customer Equivalents: (add A & B) A + B Total RCE Pursuant to King County Code 28.84.050, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the Metropolitan King County Council at a rate per month, per residential customer or residential customer equivalent, for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-477-5516. I understand that the information given is correct I understand that the capacity charge levied will be based on this information. I understand th any eviati ay res It in a revised capacity charge. Signature of Own Print Name of Owne presentative Date e----07/ 1610_6969w_nonres_sewer_cap_chg_1058,indd White - King County Yellow - Local Sewer Agdncy Pink - Sewer Customer (Rev. 10/16) 'Ionic: I Cord [Search L&I Safety & Health Claims & Insurance 41111111k4/1k Washington State Department of Labor & industries it A AZ ndux Holp Workplace Rights Trades & Licensing TRAINOR COMMERCIAL CONST INC Owner or tradesperson TRAINOR, BRIAN A Principals TRAINOR, BRIAN A, PRESIDENT TRAINOR, SUZANNE, VICE PRESIDENT (End: 09/22/2016) ATTN: Sabrina Reynolds 1925 Francisco Blvd. E, #21 SAN ANSELMO, CA 94901 415-259-0200 WA UBI No. Business type 602 512 116 Corporation Certifications & Endorsements License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no, TRAINCC950LW Effective — expiration 06/29/2005— 04/26/2021 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 547292C $12,000.00 Received by L&I Effective date 06/29/2005 06/22/2005 Expiration date Until Canceled Insurance Liberty Mutual Fire Insurance $1,000,000.00 Policy no. TB2Z91466368028 Received by L&I Effective date 10/02/2018 10/01/2018 Expiration date 10/01/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve PLUMBING FIXTURE SCHEDULE TAG DESCRIPTION DOMESTIC WATER FIXTURE UNITS DRAINAGE FIXTURE UNITS (R)WH-1 EXISTING RELOCATED WATER HEATER: STATE - 6 GALLON, MODEL PCE-6-10MSA TANK TYPE WATER HEATER, 1.5 KW, 120V/1. -- — WC-1 WATER CLOSET: AMERICAN STANDARD CADET ELONGATED PRESSURE - ASSISTED ADA COMPLIANT-1 GPF 2467.100 PROVIDE TRIP LEVER ON OPEN SIDE OF FIXTURE ALTERNATIVE CONFIGURATION MODEL 4142.801. FURNISH WITH AMERICAN STANDARD MODEL 5910.110 OPEN FRONT SEAT -ADA COMPLIANT - COLOR TO BE WHITE. 2.5 3.0 LAV-1 LAVATORY: AMERICAN STANDARD LUCERNE 0355.012 WIZURN 1231 CONCEALED ARM CARRIER. FURNISH WITH KOHLER FORTE K-10215-4 CENTER SET SINGLE HANDLE FAUCET -1.2 GPM. PROVIDE WITH GRID STRAINER DRAIN AND ADA INSULATION KIT. 1.0 1,0 WHA WATER HAMMER ARRESTOR: SIOUX CHIEF 653-A SERIES OR EQUAL BY PREVISION PLUMBING PRODUCTS, INC. 2"FD-1 FLOOR DRAIN: ZURN MODEL # Z-415-68, CAST IRON BODY, COMBINATION INVERTIBLE CLAMP AND ADJUSTABLE COLLAR, 2" BOTTOM OUTLET WITH 6" ROUND NICKEL BRONZE STRAINER. INSTALL WITH DEEP SEAL P-TRAP. -- 2.0 TP-1 TRAP PRIMER: PRECISION PLUMBING PRODUCTS MODEL#PR-500 WITH ADJUSTABLE FLOW RATE, INTEGRAL VACUUM BREAKER AND INTEGRAL BACKFLOW PREVENTER. MOUNT ABOVE CEILING IN AN ACCESSIBLE LOCATION. NOTE: CONSULT PLUMBING INSPECTOR PRIOR TO INSTALLING TRAP PRIMER. EQUAL BY SIOUX CHIEF OR ZURN. -- 4"FCO FLOOR CLEAN OUT: SIOUX CHIEF MODEL # 834-4DNR FULLY ADJUSTABLE ROUND CLEANOUT WITH POLISHED CAST NICKEL RING, COVER, AND PLUG. PLUG TO BE GAS AND WATER TIGHT. -- MB-1 MOP BASIN: FIAT MODEL MSB-2424 MOLDED STONE RESIN MOP SERVICE BASIN WITH 10" HIGH WALLS COMPLETE WITH STAINLESS STEEL STRAINER AND DRAIN FOR CAULKED CONNECTION. MOP BASIN FAUCET: CHICAGO MODEL 540-LDB97SGCCP WALL MOUNTED FAUCET WITH CHECK VALVES TO PREVENT CROSSOVER BETWEEN HOT AND COLD, WALL MOUNTED MIXING FAUCET WITH VACUUM BREAKER, SPOUT WITH 3/4" HOSE THREADS, INTEGRAL STOP ARMS, CHROME FINISH, AND WALL BRACE. 1.5 3.0 WF-1 WATER DISPENSER: WATERLOGIC INFINITI UV TOWER HOT AND COLD MULTI -STAGE FILTRATION AND ULTRAVIOLET LIGHT SANITATION. PROVIDED BY OWNER. 0.5 EWC-1 ELECTRIC WATER COOLER: ELKAY MODEL EZ(S)TL8 SELF-CONTAINED WALL MOUNT ELECTRIC TWO -LEVEL WATER COOLER WITH ADA CONFIGURATION, 8 GPH 50°F DRINKING WATER AT 90°F AMBIENT AND 80°F INLET WATER WITH EASY -TOUCH PUSHBAR ACTIVATION, EXTRA DEEP BASIN WITH INTEGRAL DRAIN, AND BUILT-IN FLOW REGULATOR. ACCESSORY APRON: ELKAY MODEL LKAPREZL APRON FOR ADA ACCESSIBILITY. THERMO-FORMED TEXTURED ABS PLASTIC EQUIPPED WITH BOTTOM COVER PLATE. 10 1.0 4" WCO WALL CLEAN OUT: SIOUX CHIEF 873 SERIES 4" CLEANOUT COVER KIT WITH 20 GAUGE STAINLESS STEEL CLEANOUT COVER, STAINLESS STEEL BOLT, AND CAST BRASS PLUG. TOTAL 6,5 10.0 SEE 3/P100 FOR PIPE SIZES / 1' PLUMBING PLAN - DOMESTIC WATER P1oo) 144" =1V-0" 10) /3`)IAT ELEC. (EQUIP. IJ 8: 112" CW LAV-1 1/2" 2"FD-K112 WC-1 7 3 DOMESTIC WATER RISER DIAGRAM P100 / WF-1 EWC-1 112"CW GENERAL NOTES SEE 4/P100 FOR PIPE SIZES 2 PLUMBING PLAN - WASTE AND VENT P100 1 1/4" =1-0" J.8 2" V—, - ` 11/2"V •-- 2"V 2" SS-- T-2"V 4 WASTE AND VENT RISER DIAGRAM P1o0 j ....___ _...... `-2"V ,/\ 2"V 4" FCO I COPY Freoho1 I��; G[a- On-7(0 .ar! approval 000blect to errors a0o 4eJ�-�r" sv2: o; 96ylstrye(jon oytpmtants th Tot 1 1/2" V EWC-1 SEPARATE PERMIT REQUIRED FOR: echanical Electrical I'lumbing Gas Piping City of Tukwila BUILDING DIVISION L•.. ''City of To BUILDING C RECEIVED CITY OF TUKWILA MAY 302019 PERMIT CENTER PLUMBING PLAN KEYNOTES O 1 ELECTRICAL ROOMS, TECHNOLOGY/DATA CLOSETS, EXIT STAIRWELLS, AND ELEVATOR EQUIPMENT ROOMS SHALL UNDER NO CIRCUMSTANCES HAVE PIPING OR DUCTWORK, OR EQUIPMENT INSTALLED IN OR ROUTED THROUGH THESE ROOMS OR AREAS EXCEPT FOR BRANCH PIPING OR DUCTWORK SPECIFICALLY SERVING THE ROOM OR AREA. DEDICATED SPACE SHALL EXTEND VERTICALLY FROM FLOOR TO STRUCTURAL CEILING. 2 THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND PROPER INSTALLATION OF ALL PLUMBING SYSTEMS. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY OFFSETS AND FITTINGS WHICH MAY BE REQUIRED DUE TO SPACE CONSTRAINTS OR OTHER CONDITIONS NOTIFY ENGINEER IMMEDIATELY SHOULD ANY CONFLICTS ARISE BETWEEN THE INFORMATION PRESENTED AND THE FIELD CONDITIONS. 3 CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH THE REQUIREMENTS OF ALL NOTES SHOWN ON CONTRACT DOCUMENTS PRIOR TO BID. REFER TO DRAWINGS, SPECIFICATIONS, AND DRAWINGS OF OTHER DISCIPLINES FOR ANY ADDITIONAL REQUIREMENTS. 4 CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING PROCESS AND FIELD VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL TAKE ALL INTERFERENCES INTO CONSIDERATION. 5 ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF LOCAL CODES AND ORDINANCES. 6 DO NOT ROUTE ANY WATER CONVEYING PIPE OVER ELECTRICAL EQUIPMENT. 7 ROUTE ALL OVERHEAD PIPING TIGHT TO THE BUILDING STRUCTURE 8 PROVIDE SHUTOFF VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY LINES. VALVES, FITTINGS, ESCUTCHEONS, ETC SHALL BE CHROME PLATED. 9 MAINTAIN ALL MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR ALL EQUIPMENT. 10 SEE SHEET MP000 FOR SPECIFICATIONS. 11 SEE SHEET MP001 FOR RESPONSIBILITY SCHEDULE 12 ANY UNUSED, BELOW -FLOOR SANITARY PIPING UNDER TENANT SPACE IS TO BE REMOVED BY THE TENANT. 13 DOMESTIC WATER IS MASTER -METERED BY LANDLORD. 1 CONNECT NEW 4" SANITARY SEWER PIPING WITH CLEANOUT AS INDICATED INTO LANDLORD PROVIDED 4" SANITARY SEWER STUB -IN. FIELD VERIFY EXACT SIZE, LOCATION AND INVERT ELEVATION PRIOR TO BIDDING. SEE DETAIL 1/P200. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2 CONNECT NEW 2" VENT PIPING INTO LANDLORD PROVIDED 2" VENT STUB -IN. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BIDDING. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION.LEVATION PRIOR TO BIDDING. SEE DETAIL 1/P200. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3 PLUMBING CONTRACTOR SHALL PROVIDE DRAWING TUBE HOLDER FOR STORAGE OF ALL CONTRACTORS "AS -BUILT" DRAWINGS. REFER TO 5/P200 FOR ADDITIONAL INFORMATION. LOCATE/INSTALL NEAR ELECTRICAL PANELS AND TELECOMMUNICATIONS TERMINAL BOARD. 4 CONNECT NEW 3/4" COLD WATER LINE WITH SHUTOFF VALVE INTO LANDLORD PROVIDED 3/4" COLD WATER STUB -IN. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BID. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 5 PROVIDE 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION. SEE DETAIL 6/P200. 6 ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7 RELOCATE EXISTING WATER HEATER ON DECK ABOVE MOP BASIN. PLUMBING CONTRACTOR SHALL PROVIDE A 6" DEEP DRAIN PAN. COORDINATE WITH ELECTRICAL CONTRACTOR. SEE DETAIL 3/P200. EXISTING WATER HEATER 1.5 KW, 120V11. 8 PROVIDE WATER HAMMER ARRESTER IN THE DOMESTIC COLD WATER PIPING. WATER HAMMER ARRESTER TO BE LOCATED IN AN ACCESSIBLE LOCATION. 9 ROUTE 3/4" DRIP PAN DRAIN AND 3/4" (R)WH-1 PRESSURE RELIEF VALVE PIPING TO MOP BASIN WITH AIR GAP AT DISCHARGE. AIR GAP SHALL BE TWO TIMES THE DIAMETER OF THE FIXTURE DRAIN, NO LESS THAN 1". SLOPE CONDENSATE DRAINS AT 1/8" PER FOOT TOWARDS TERMINATION. DO NOT COMBINE. 10 DO NOT ROUTE ANY PIPING OVER ELECTICAL SWITCH GEAR. FIELD VERIFY PRIOR TO INSTALLATION. 2 ?Gicift. oo76 11 SEE DETAIL 41P200 FOR FLOOR DRAIN DETAIL 12 SEE DETAIL 2/P200 FOR PIPE HANGING DETAILS. MORPHE 22 FOURTH STREET, 4TH FLOOR SAN FRANCISCO, CALIFORNIA 94103 fhin diuiiels AR CH I TECTS 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com CONSULTANTS: Gausman &Moore Mechanical and Electrical Engineers 1700 West Highway 36 - Suite 700 Roseville, Minnesota 55113 (651) 639-9606 Fax (651) 639-9618 Project No, 86806 SEAL/SIGNATURE STORE #: 047 PROJECT: MORPHE WESTFIELD SOUTHCENTER SPACE# 1530 637 SOUTHCENTER MALL TUKWILA, WA 98188 A/E PROJECT NO.: DRAWN BY: M0047 PAS CHECKED BY: KRU ISSUES AND REVISIONS: 100% CHECKSET LL/PERMIT/BID 0516.2019 05.23.2019 SHEET TITLE: PLUMBING PLANS P100