HomeMy WebLinkAboutPermit PG19-0114 - SHASTA BEVERAGES / WATER MAIN REVISION - PRV ASSEMBLY AND PIPINGSHASTA BEVERAGES, INC- WATER MAIN REVISION 1227 ANDOVER PARKE PGI9-01 14 Parcel No: Address: Project Name: �~^�«x °~� Tukwila ~~�^� uvo n ��x���Una Department of Community Development G30OSomthmenterBoulevard, Suite #1OD Tukwila, Washington 9D1Q8 Phone: 206'431'3670 Inspection Request Line: 3OG'438'935O Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 3523049072 Permit Number: l2Z7ANDOV[RPARK E Issue Date: Permit Expires On: SMA5TABEVERAGES, INC - WATER MAIN REVISION PGI9'O1l4 I/IO/2D2O 7/8/2020 Owner: Contact Person: Name: Address: Contractor: License No: Lender: NATIONAL BEVERAGE CORP 8100SVV10TH3T3TE4000, PLANTATION, WA, 33324 l9l6BOmA|RDRSW, SEATTLE,WA, 98116 AUBURN MECHANICAL INC P0BOX Z49,AUBURN, WA, 9OO7l AV8URK4|1638A ''' Phone: (206)433-8997 Phone: (253)838-9780 Expiration Date; 9/12/2020 DESCRIPTION OF WORK: REMOVE EXISTING PRV ASSEMBLY AND ASSOCIATED PIPING, CONNECT TO EXISTING WATERMAIN As IT ENTERS THROUGH THE FLOOR, INSTALL NEW PRV ASSEMBLY AND ASSOCIATED PIPING. Valuation cfWork: $35'00000 Water District: TUKVV|LA Sewer District: TUKWILA Fees Collected: $202.19 Current Codes adopted bythe City mfTukwila: international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[Z96~468: WA State Energy Code: Date: 2017 2017 2017 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree t - conditions attached to this permit. Signature: Print Name: l"q,LL 76, fi4<o Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 2: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 3: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 4: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 5: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 6: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 7: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 9: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 10: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit far, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 12: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 13: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. PC mill/ Project No. Date Application Accepted: le) 1 Date Application Expires: - 3- '00 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.:352304-9072 1227 Andover Park East Site Address: Suite Number: Floor: 1 Shasta Beverage Inc Tenant Name: New Tenant: 0 Yes 1 ..No PROPERTY OWNER Name: Shasta Beverage Inc Address: 1227 Andover Park East City: Tukwila state: w Zip: 98188 CONTACT PERSON — person receiving all project communication Name: David Kehle Address: 1916 Bonair Dr SW City' Seattle State: WA zip: 98116 Phone: 206-433-8997 Fax: Email: dkehle@dkehlearch.com PLUMBING CONTRACTOR INFORMATION Company Name: Aubum Mechanical Address: PO Box 249 City: Auburn State: WA zip: 98791 Phone: 253-838-9780 Fax: Contr Reg No.: Aubum1162BAr Exp Date: 09-12-202C Tukwila Business License No.: BUD-0994349 Valuation of Project (contractor's bid price): $ 35,000 Scope of Work (please provide detailed information): REMOVE EXISTING PRV ASSEMBLY AND ASSOCIA I ED PIPING, CONNECT TO EXISTING WA I ERMAIN AS IT ENTERS THROUGH THE FLOOR, INSTALL NEW PRV ASSEMBLY AND ASSOCIA FED PIPING Building Use (per Intl industrial Building Code)- Occupancy (per Int'I Building Code): F1 Utility Purveyor: Water: CITY OF TUKWILA Sewer HAApplicalionslForms-Applications On Line \ 2011 Applications \Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page I of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective `/ device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter /x_ Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR 'THIS PERMIT. BUILDING OWNS AUT D AGENT: Signature: /# Date: 08/09/2019 Print Name: David Kehle Mailing Address: 1916 Bonair Dr SW Day Telephone: 206-433-8997 Seattle WA 98116 City State Zip H:\Applications\Forms-Applications On Line 12011 Applications \ Plumbing Permit Application Revised 8-9-l1.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number • DESCRIPTIONS . PermitTRAK ACCOUNT - . I . QUANTITY PAID $202.19 PG19-0114 Address: 1227 ANDOVER PARK E Apn: 3523049072 $202.19 Credit Card Fee $5.89 Credit Card Fee R000.369.908.00.00 0.00 $5.89 PLUMBING $188.75 PERMIT FEE R000.322,100.00.00 0.00 $116.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $37.75 TECHNOLOGY FEE $7.55 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18328 R000.322.900.04.00 0.00 $7.55 $202.19 Date Paid: Tuesday, August 13, 2019 Paid By: NICHOLAS HEATON Pay Method: CREDIT CARD 013975 Printed: Tuesday, August 13, 2019 2:38 PM 1 of 1 SYSTEMS CO TUKWIL4 ETRAKIT 6I08 5UUTHCENTER BLVD TUKWILu^ WA 98188 286'433'I870 CITY OF TVKWIL4 0017340000802374464500 Date: 88/13/I019 02:3826 PM CREDIT CARD SALE VISA CARD NUMBER: *******+**58I1 K TnAN AMOUNT: $202.19 APPROVAL [D: 0I3975 KE[OKo #: 000 CLERK ID: kandace K {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWILA ETRAKIT 6208 SDUTHCENTEK BLVD TUKwILA, WA 98188 286'433'1870 CITY OF TUKWIL4 Date: 08/13/2019 02:38:26 PM [RsozT cAno SALE VISA CARD NUMBER: **~****~*~5811 K TRAN AMOUNT: $202,19 APPROVAL [o: 013975 KE[0RO #: 000 CLERK ID: kandace Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NQ. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of inspection: G ,i746-- t7i Address: %Z2-7 OM RA Date Called: Special Instructions: Date Wanted: a.m. p.m. `Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1R4VG# /14 Inspector: Date: 1 7 11 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development - Jack Pace, Director February 5, 2020 David Kehle 1916 Bonair Dr SW Seattle WA 98116 RE: Request for Permit Extension Plumbing Permit PG19-0114 Shasta Beverages, Inc. — Water Main Revision — 1227 Andover Park E Dear Mr. Kehle, Allan Ekberg, Mayor This letter is in response to your written request for an extension of permit number PG19-0114 received in our office on January 15, 2020. It has been determined that the City of Tukwila Building Department does not need to extend the permit at this time as an inspection was requested on January 24, 2020 and performed on January 24, 2020. Based on the inspector's report, this inspection automatically extends the permit 180 days. The new expiration date is July 25, 2020. If you have any concerns or questions, feel free to contact me in the permit center at 206 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. PG19-0114 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov "Pak Request for Permit 1..cer ion # I Current Expiration Date: Extension Request: Approved for 1> days Denied (provide explanation) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Jerry I -light RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Permit Extension EL19-0449 Glycol Room Permit Extension M19-0010 Glycol Room Permit Extension M19-0086 Can Line 2 Permit Extension PG19-0114 Water Main Rev. Dear Mr. Hight, Signature n it i als )1-1 IIECEIVED CITY OF TUKWILA JAN 15 70711 PERMIT CENTER I am in receipt of letters from Bill Rambo, permit tech, that the above permits will be expiring soon. 1 am asking for an extension to these permits for the following reasons: 1. There are ongoing owner revisions due to construction inadequacies that need to be resolved and correction comments from Fire will impact the permits. Glycol Room has had a revision resubmittal and has not been re approved. 2. The Can Line 2 and Water Main inspection was dropped by Shasta due to a personnel change recently impacting call for inspections. 3. There are sequences of projects that need to be completed prior to having final inspections occur due to limitations on space in the facility ( ie build this first and then build the next which takes longer to complete). This has impacted the Can Line 2 and Water Main Revision construction and therefore there was nothing to inspect. Can Line 2 can have inspections called for now. 4. There are on going City concerns that are being addressed delaying construction and inspections. This impacts the Glycol Room from Fire. 5. There are some cost implications of the construction which impact cash flow for construction. I believe these are adequate to allow for the extension of the permits. Sincerely, David Kehle (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com 1916 Bonair Drive S.W. Seattle, WA 98116 (c) City of Tukwila Department of Community Development 1/2/2020 DAVID KEHLE 1916 BONAIR DR SW SEATTLE, WA 98116 RE: Permit Application No. PG19-0114 SHASTA BEVERAGES, INC - WATER MAIN REVISION 1227 ANDOVER PARK E Dear DAVID KEHLE, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 8/12/2019, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 2/13/2020. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: PG19-0114 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Joanna S encer From: dkeh|e@dkehlearchzom Sent: Thursday, August 15,2D191U:0OAM To: Joanna Spencer Subject: Re: PG19-0114 Shasta Beverage, Inc @ 1227 ANDOVER PARK E Joanna, Thanks for your initial review. You are correct that we are not installing a backflow device but we are installing 2 PRV inside the building perAuburn's plans. My mistake on the plumbing form. Should | resubmit the plumbing form orcan you just correct for me? | had talked with Auburn toconfirm this. Dave Hello Dave, >P\Nisreviewing your permit application and needs clarification isa >bachOovvisbeing installed asindicated onthe 2ndpage ofyour >app|ication. >PRVisnot ubackOow'somaybe backOoxvwas marked bymistake onyour >app|ication. � >]oannaSpencer > Development Engineer Tukwila Public Works >630OSnuthcenterBlvd, Suite lOU,Tukwila, VVA9O188'2S44 > Phone: 206431'344O Fax: ZO6431'3665 � » CAUTION: This email originated fnornoutsdetheChYofTukxvkane1wxork.9|easeDONOTopenattachmentsurdick|inks from anunknown orsuspicious origin. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0114 DATE: 08/12/19 PROJECT NAME: SHASTA BEVERAGE, INC WATER MAIN REVISION SITE ADDRESS: 1227 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building MU #46\ Division 0) Al\ Public Works Fire Prevention Structural LI Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 08/13/19 Structural Review Required REVIEWER'S TIALS: DATE: LI APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Atiooki0V1 Denied (corrections entered in Reviews) (ie: Zoning Issues Notation: tikott. ,v 0-kW) 111 'TO DUE DATE: 09/10/2019 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire El Ping D PW 0 Staff Initials: 12/18/2013 industries (httos://Ini.wa.gov) Contractors AUBURN MECHANICAL INC Owner or tradesperson Principals THODAY, DAVID V, PRESIDENT JOHNSON, STACYANNE, PRESIDENT JOHNSON, KIM PAUL, SECRETARY Doing business as AUBURN MECHANICAL INC PO BOX 249 AUBURN, WA 98071 253-838-9780 KING County WA UBI No. Business type 600 074 968 Corporation Governing persons STACY A JOHNSON KIM JOHNSON; RYAN HOWARD MCMAHAN; ILicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. AUBURMI163BA Effective — expiration 01 /01 /1984— 09/12/2020 Bond Travelers Cas and Surety Co of America Bond account no. 106958648 Received by L&I 09/24/2018 $12,000.00 Effective date 10/01/2018 Expiration date Until Canceled Bond history Insurance Continental Insurance Co $1,000,000.00 Policy no. 6072614904 Received by L&I Effective date 08/23/2019 10/01/2018 Expiration date 10/01/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts GENERAL NOTES 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF 2015 INTERNATIONAL BUILDING CODE (IBC), 2015 WASHINGTON STATE ENERGY CODE (WSEC), 2015 UNIFORM PLUMBING CODE (UPC), 2015 INTERNATIONAL FUEL GAS CODE (IFGC), AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING, OR ACCESSORY. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. 3. ITEMS MARKED AS TYPICAL APPLY TO THAT DRAWING SHEET ONLY. UNLESS NOTED OTHERWISE, DETAILS MARKED AS TYPICAL APPLY TO THE DRAWING SET. 4. COORDINATE INSTALLATION WITH BUILDING STRUCTURE AND ALL OTHER TRADES (ARCHITECTURAL, CIVIL, ELECTRICAL, STRUCTURAL, LANDSCAPE, ETC) PRIOR TO FABRICATION, PURCHASE, AND/OR INSTALLATION OF SCOPE OF WORK. VERIFY SPECIFICATIONS AND PROJECT REQUIREMENTS FOR CUTTING AND PATCHING. COORDINATE AND VERIFY CLEARANCES BEFORE COMMENCING WORK. DIMENSIONS TO EQUIPMENT TO BE INCLUDED WITH AS-BUILTS. 5. EQUIPMENT, VALVES, AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS UNLESS SHOWN ON THE ARCHITECTURAL DRAWINGS. REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. OBSERVE EQUIPMENT CLEARANCES. ALL MECHANICAL EQUIPMENT CLEARANCES NOTED ON THE DRAWINGS AS 36" FOR MECHANICAL ACCESS OR ELECTRICAL ACCESS LESS THAN 460V, 42" FOR ELECTRICAL ACCESS OF 460V, OR SPECIFIED FOR OTHER CLEARANCES PER THE MANUFACTURER. 6. REFER TO STRUCTURAL FOR ALLOWABLE METHODS AND ACCEPTABLE LOADS FOR HANGING DUCTS AND PIPES FROM THE STRUCTURAL MEMBERS. 7. VERIFY PROJECT SEISMIC REQUIREMENTS. INSTALL SEISMIC BRACING FOR ALL DUCTWORK (GREATER THAN 33.0 OR 6 SQUARE FEET), EQUIPMENT (>400# & 4 FEET ABOVE THE FLOOR, OR 75# INLINE), AND PIPING (>3"0 FOR Ip=1.0) PER IBC REQUIREMENTS. POSITIVELY ATTACH DIFFUSERS TO CEILING GRID. UNLESS PROVIDED BY THE STRUCTURAL ENGINEER, USE THE SMACNA SEISMIC RESTRAIN MANUAL FOR GUIDELINES, 8. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. VICINITY MAP/SITE MAP AREA OF WORK ft) PLUMBING NOTES 1. CONTRACT DOCUMENT DRAWINGS ARE SCHEMATIC. THEY ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT. THEY DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE PLUMBING CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 3. SLOPE ALL WASTE PIPING AT 2, UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE ID INDICATED ON DRAWINGS). 4. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313.3 OF THE 2015 UNIFORM PLUMBING CODE & SECTION 1613.3 OF THE 2015 IBC, PROVIDE EARTHQUAKE SWAY BRACING AT 40' INTERVALS FOR ALL PIPING WHICH IS GREATER THAN 3" WHICH HAVE HANGERS THAT EXCEED 12" IN LENGTH AS DESCRIBED BY THE SMACNA BRACING MANUAL. 5. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 6. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. IF THE ELECTRICAL IS GROUNDED TO THE PIPE SYSTEM THEN ALL DIELECTRIC CONNECTIONS REQUIRE A JUMPER TO MAINTAIN ELECTRICAL GROUNDING. SCOPE OF WORK 1. REMOVE EXISTING PRV ASSEMBLY AND ASSOCIATED PIPING. 2. CONNECT TO EXISTING WATER MAIN AS IT ENTERS THROUGH THE FLOOR. 3. PROVIDE NEW PRV ASSEMBLY AND ASSOCIATED PIPING. DRAWING SHEET LIST P0.01 PLUMBING COVER SHEET P1.01 .C.1 - PLUMBING FLOOR PLAN 6" DCW PRV-L1-2 PRV-L1-1 SYMBOL LEGEND DOMESTIC COLD WATER (DCW) DOMESTIC HOT WATER (DHW) DOMESTIC HOT WATER RETURN (DHWR) SANITARY WASTE (W) VENT (V) STORM DRAIN (SD) OVERFLOW STORM DRAIN (ODD) GAS MPG MEDIUM PRESSURE GAS PIPE CAP PIPE BREAK 0 PIPE UP PIPE DOWN PIPE TEE UP PIPE TEE DOWN PIPE FLANGE UNION REDUCER DIRECTION OF FLOW m FLOOR CLEANOUT WALL CLEANOUT CIRC PUMP POINT OF CONNECTION BALL VALVE D4 GATE VALVE BALANCING VALVE GAS VALVE GLOBE VALVE ANGLE GLOBE VALVE 3 WAY MOTORIZED VALVE Chi PRESSURE REGULATOR VALVE N CHECK VALVE PRESSURE RELIEF VALVE PRESSURE REDUCING VALVE BACKFLOW PREV. STATION ED PLUMBING FIXTURE UNION (TYP.) STRAINER, 200#WOG (TYP.) BUTTERFLY VALVE (TYP) PRESSURE GAUGE W/COCK (TYP) 6" DCW DCW PRESSURE REDUCING VALVE 0 DETAIL NTS PLUMBING ABBREVIATIONS ABBR FULL NAME ABBR FULL NAME ABBR FULL NAME AAV AUTOMATIC AIR VENT EXH EXHAUST N2 NITROGEN ABV ABOVE EXP EXPANSION N20 NITROUS OXIDE AD ACCESS DOOR EXTR EXTRACTOR NC NORMALLY CLOSED AFF ABOVE FINISHED FLOOR (F) FUTURE NG NATURAL GAS (LOW PRESSURE) AG ABOVE GRADE F FIRE, FAHRENHEIT NIC NOT IN CONTRACT AGD ANESTHIC GAS DISPOSAL FA FREE AREA NO NORMALLY OPEN AL ALUMINUM FC FLEXIBLE CONNECTION NP NON -POTABLE APRX APPROXIMATELY) FCO FLOOR CLEAN OUT NTS NOT TO SCALE ARCH ARCHITECTURAL) FCU FAN COIL UNIT 02 OXYGEN ATM ATMOSPHERE FD FLOOR DRAIN OSA OUTSIDE AIR AV ACID VENT FLA FULL -LOAD AMPS OC ON CENTER AW ACID WASTE FOG FATS, OILS, AND GREASE OD OUTSIDE DIMENSION BAS BUILDING AUTOMATION SYSTEM FPM FEET PER MINUTE OFCI OWNER FURNISHED CNTR INSTALLED BFP BACKFLOW PREVENTER FPS FEET PER SECOND OFD OVERFLOW DRAIN BG BELOW GRADE FS FLOOR SINK OPNG OPENING BHP BRAKE HORSE POWER '/FT FOOT, OR FEET ORL OVERFLOW RAIN LEADER BLDG BUILDING G GAS (LINE) OSD OVERFLOW STORM DRAIN BOB BOTTOM OF BEAM GALV GALVANIZED 0 PHASE OR DIAMETER BOP BOTTOM OF PIPE GC GENERAL CONTRACTOR POC POINT OF CONNECTION BOTT BOTTOM GI GREASE INTERCEPTOR PRV PRESSURE REDUCING VALVE BTU BRITISH THERMAL UNITS GLYE ETHYLENE GLYCOL PSI POUNDS PER SQUARE INCH BTUH BRITISH THERMAL UNITS PER HOUR GLYP PROPYLENE GLYCOL PW PUMPED WASTE BTU/H BRITISH THERMAL UNITS PER HOUR GPH GALLONS PER HOUR QD QUICK DISCONNECT C CONDENSATE GPM GALLONS PER MINUTE (R) RELOCATE CA COMPRESSED AIR GW GREASE WASTE RD ROOF DRAIN CB CATCH BASIN GWB GYPSUM WALL BOARD RED. REDUCE, OR REDUCED CC CONTROLS CONTRACTOR HB HOSE BIBB REQ'D REQUIRED CHWR CHILLED WATER RETURN HE HELIUM RIO ROUGH IN ONLY CHWS CHILLED WATER SUPPLY HHWR HEATING HOT-WATER RETURN RL RAIN LEADER CI CAST IRON HHWS HEATING HOT-WATER SUPPLY RPBP RED. PRESSURE BACKFLOW PREV. CNDS CONDENSATE HG HOT -GAS LINE SD STORM DRAIN CNTR CONTRACTOR HP HEAT PUMP, OR HORSE POWER SF SQUARE FEET CL CENTERLINE HR HOUR SS SANITARY SEWER CO CLEAN OUT HWR HOT-WATER RETURN SST L STAINLESS STEEL CHWR CHILLED WATER RETURN HWS HOT-WATER SUPPLY STL STEEL CHWS CHILLED WATER SUPPLY HX HEAT EXCHANGER SUC SUCTION LINE CI CAST IRON HZ HERTZ SUSP SUSPENDED CNDS CONDENSATE ICW INDUSTRIAL COLD WATER TPL TRAP PRIMER LINE CNTR CONTRACTOR ID INSIDE DIMENSION TOD TOP OF DUCT CL CENTERLINE IE INVERT DIMENSION TOP TOP OF PIPE CO CLEAN OUT IE THAT IS TOS TOP OF STEEL DCW DOMESTIC COLD WATER IHW INDUSTRIAL HOT WATER TP TRAP PRIMER DCV DOUBLE CHECK VALVE IHWC INDUSTRIAL HW CIRCULATION TXV THERMAL EXPANSION DCBP DOUBLE CHECK BACKFLOW PREV. ")IN INCH, OR INCHES TYP TYPICAL DDC DIRECT DIGITAL CONTROL INS INSULATION UNO UNLESS NOTED OTHERWISE TOES DEGREE KW KILOWATT V VENT DFU DRAINAGE FIXTURE UNIT INT INTERLOCK VAC VACUUM PIPING DHW DOMESTIC HOT WATER #/LBS POUNDS VFD VARIABLE FREQUENCY DRIVE DHWR DOMESTIC HOT WATER RETURN LIQ LIQUID LINE VIF VERIFY IN FIELD DN DOWN LWT LEAVING WATER TEMPERATURE VSD VARIABLE SPEED DRIVE DWG DRAWING MA MEDICAL AIR VTR VENT TO ROOF (E) EXISTING MAX MAXIMUM W WASTE EC ELECTRICAL CONTRACTOR MBH 1,000 BTU/H WC WATER COLUMN EG FOR EXAMPLE MCA MINIMUM CIRCUIT AMPACITY WCO WALL CLEANOUT EER ENERGY EFFICIENCY RATIO MH MAN HOLE WH WALL HYDRANT EFF EFFICIENCY MIN MINIMUM WO WASTE OIL ELEV ELEVATION MPG MEDIUM PRESSURE GAS WSFU WATER SOURCE FIXTURE UNIT EQUIP EQUIPMENT MSV MEDICAL SURGICAL VACUUM WT WEIGHT EXP EXPANSION MT MOUNT AN WRAP EWT ENTERING WATER TEMPERATURE (N) NEW W/ WITH ZCV ZONE CONTROL VALVE SEPARATE PERMIT RE UIRED FOR: Mrchartictil Ek+ctricxl ❑ Plumbing CX Gas Piping City of Tukwila BUILDING O'VISION RECE ' E 0 PU61-Vt.'' PRESSURE REDUCING VALVE - DOMESTIC COLD WATER SCHEDULE TAG LOCATION MAKE MODEL SIZE (IN.) WSFU GPM PSIG DROP WEIGHT (LBS) INLET PSI OUTLET PSI NOTES PRV-L1-1 SOUTH WALL OF SW CORNER WATTS F115-74 6 N / A 1300 10 320 150 60 PRV-L1-2 SOUTH WALL OF SW CORNER WATTS LF25AUB 2 N / A 20 10 15 150 60 REVIEWED r.OR CODE COMPLIANCE APPROVED AUG 22 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY 1-IF TUKWILA AUG 1 2 2019 PEPw111 CENTER Auburn 'Mechanical When J?t'i f0i"i11C711CP counts P.O. Box 249 2623 West Valley Hwy. Auburn, WA 98071 Tel: (253)838-9780 Fax: (253)833-1384 AU-BU-RM1163BA GENERAL NOTES 'NA- 0 4".'-}, iNfjjtt d - - ". S-I ., 07/2. J (2,1,9 0 PERMIT SET 7/23/19 No. Revision/Issue Date" SHASTA INCOMING DCW RELOCATE 1227 ANDOVER PARK E TUKWILA, WA 98188 sh P0.01 PLUMBING COVER SHEET awn By GAH Date 7/2/2019 NO SCALE (E)3" NG (EXISTING) (Eli" H ) EXISTING 5PS GAS SERVICE A METER, EXISTING T AL LOAD OF 15,450 CFH AT 550-0 ITXL LENGTH. PER TAB. 402.4(7), THE CAPA'TX OF A 3" PIP IS 24,000 CF CONNECT TO EXISTING WATER LINE, EXISTING WATER LINE LOCATION - TO BE REMOVED. • (E) FROM CI-Y WATER SUPPLY. EXISTING RPBA AND METER LOCATED 1,1 HOTBOX OUTSIDE OF BUILDING. REMOVE AND REPLACE INCOMING DCW PRV ASSEMBLY APPROXIMATELY 5'-0' TO THE EAST TO ALLOW SPACE FOR NEW ELECTRICAL ROOM, -(E)2" NG DN FACTORY P ECE OF EQUI ENT (5000 FH) E)HOT E. COLD HOSE BIBBS (E)3/4" -;E)2 1/2" NG (D1/2" H R PRV-L -01 PRV-L1-02 SEE 1/P0,0 /-(E)1/2" HAIR (E)2" NG DN T FACTORY PI OF EDUIPM T (750 CF ,-(E)3/4" DHW (E)3 / 4" DCW E)3'A" DCW (E)HOT g, COLD HOSE BIBBS SOUTH WAREHOUSE FLOOR PLAN 1/8" =11-0" 1 1/ DC,/ (E T NC MAIN) V(719-0114 RECEPVED CrIN' OF TUKWILA AUG 1 2. 2013 LERIvliT CENTER REVIEWED FOR CODE COMPLIANCE • APPROVED AUG 22 2019 City of Tukwila UILDING DIVISION Auburn /Mechanical • When p,;:fivinnticc count, P.O. Box 249 2623 West Valley Hwy. Auburn, WA 98071 Tel: (253)838-9780 Fax, (253)833-1384 AU-BU-RM1163BA GENERAL NOTES .,--, 07/28/2029 0 PERMIT SET 7/23/19 No. Revision/Issue Date SHASTA INCOMING DCW RELOCATE 1227 ANDOVER PARK E TUKWILA, WA 98188 .. P1.01.C.1 PLUMBING FLOOR PLAN GAH 7/2/2019 s1/8" = 1'-0"