Loading...
HomeMy WebLinkAboutPermit PG19-0141 - PROVIDENCE / BREAKROOM - CAP WASTE DRAIN AND LINES, ADD ICEMAKER BOXES, REPLACE SINKS & FAUCETS, ETCPROVIDENCE 2811 S 102ND ST 200 PGI 9-0141 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gpv PLUMBING/GAS PIPING PERMIT 0423049190 Permit Number: PG19-0141 2811 S 102ND ST 200 Project Name: PROVIDENCE Issue Date: 10/8/2019 Permit Expires On: 4/5/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SABEY CORPORATION 12201 TUKWILA INTERN'L BLVD FO , SEATTLE, WA, 98168 FAWN FRANKSEN-GARNETT Phone: (206) 605-2202 7018 S 220TH ST , KENT, WA, 98032 WESTERN MECH CONTRACTORS INC 7018 S 220 ST , KENT, WA, 98032 WESTEMC919QL Phone: (253) 946-9544 Expiration Date: 1/15/2020 DESCRIPTION OF WORK: WORK IN BREAK ROOM AREA: CAP EXISTING WASTE SERVING CUP DRAIN IN FLOOR AND CAP ASSOCIATED LINES. FURNISH & INSTALL 2 NEW ICEMAKER BOXES W/HAMMER ARRESTORS. REPLACE EXISTING SINKS AND FAUCETS AND INSTALL 2 NEW GARBAGE DISPOSALS, DISCONNECT EXISTING AND CONNECT NEW DISHWASHERS SUPPLIED BY OWNER. Valuation of Work: $6,553.00 Water District: TUKWILA Sewer District: VALLEY VIEW Fees Collected: $198.17 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: lV |hearbycertify that | have read and examined this permit and know the same tobetrue and correct. All provisions of law and otclinances governing this work will be complied with, whether specified herein or not, The granting of this permit does not presume to give authority to violate or cancel the provisions ofany other state nrlocal laws regulating construction orthe performance ofwork. |amauthorized tnsign and obtain this development permit and agree tothe conditions attached tothis permit. This permit shall become null and void ifthe work bnot commenced within 18Odays for the date ofissuance, orif the work is suspended orabandoned for aperiod cf180days from the last inspection. PERMIT CONDITIONS: 1: ***PLUK4B|NG/GASPIPING PERMIT CONDITION5*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall betested and approved asrequired bythe Plumbing Code and Fuel Gas Code. Tests shall beconducted inthe presence ofthe Plumbing Inspector. itshall bethe duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work isready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision ismade tnprotect such pipe from freezing, All hot and cold water pipes installed outside the conditioned space shall beinsulated tuminimum R'3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall beprotected bysteel nail plates not less than 18gauge. 9: Piping through concrete urmasonry walls shall not besubject toany load from building construction. No plumbing piping shall bedirectly embedded lnconcrete o/masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements nfthe building code. 11: Piping inthe ground shall belaid onafirm bed for its entire length. Trenches shall beback0Ued|nthin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cindenUU,frozen earth, o,construction debris. 12: The issuance nfapermit orapproval ofplans and specifications shall not beconstrued tobpapermit for, or anapproval of, any violation ofany ufthe provisions nfthe Plumbing Code urFuel Gas Code urany other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use orother occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 4OZufWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438'g35O 8004 GROUNDWORK 1900 PLUMBING FINAL o 8005 ROUGH -IN PLUMBING CITY OF TUKWRLJ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Ptrmit No. Project No. Date Application Accepted: Date Application Expires: PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan ieview. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 2811 South 102nd St. Tukwila Providence King Co Assessor's Tax No.: 0423094190 Suite Number: 210 Floor: 2 New Tenant: Li Yes ..No PROPERTY OWNER Name: Riverfront Technical Park LLC Address: 2201 Tukwila Int. Bldg 4th Floor City: Seattle State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Fawn Franksen-Garnett Address: 7018 So. 220th St. City: Kent State: WA Zip: 98032 Phone: (206) 605-2202 Fax: (253) 946-9550 Email: permits@westernrnech.us PLUMBING CONTRACTOR INFORMATION Company Name: Western Mechanical Contractors Address: 7018 So. 220th St. City: Kent State: WA Zip: 98032 Phone: Fax: (253) 946-9541 (253) 946-9550 Contr Reg No.: wEsihmc919% Exp Date: 01/15/2020 Tukwila Business License No.: BUS 1994452 Valuation of Project (contractor's bid price): $ 6,553 Scope of Work (please provide detailed information): Work in break room area: Cap existing waste serving cup drain in floor and cap associated lines. Funa & install 2 new icemaker boxes w/hammer arrestors. Replace existing sinks and faucets and install 2 new garbage disposals, disconnect existing and connect new dishwashers supplied by Owner. Building Use (per Intl Building Code): Office Occupancy (per Intl Building Code): Utility Purveyor: Water: Tukwila Sewer. Valley View Sewer District H :Applications Forms -Applications On Line•2011 Applications Plumbing Permit Application Revised 8-9-1 I .docx Revised: August 21)11 Page I of 2 ' t Indicate type of plumbing fixtures and as piping outlets being installed and the quantt, w elow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks d"--- Rain water system — per dram (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment 1 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 1 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases.. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUTHO IZED AGENT: Signature: -�`' �• Date: 09/30/2019 Print Name: Fawn Franksen-Garnett Day Telephone: (206) 605-2202 Mailing Address: 7018 So. 220th St. Kent WA 98032 City State Zip Nr Applications'Forms-Applications On Line:201 I Applications•Plumbine Permit Application Revised 8-9-1 Ldocx Revised: August 201 I bh Page 2 of 2 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $198.17 PG19-0141 Address: 2811 S 102ND ST 200 Apn: 0423049190 $198.17 Credit Card Fee $5.77 Credit Card Fee R000.369.908,00,00 0,00 $5.77 PLUMBING $185.00 PERMIT FEE R000.322.100.00.00 0.00 $113.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $37.00 TECHNOLOGY FEE $7.40 TECHNOLOGY FEE R000.322.900.04.00 0.00 $7.40 TOTAL FEES PAID BY RECEIPT: R18703 $198.17 Date Paid: Monday, September 30, 2019 Paid By: FAWN FRANKSEN Pay Method: CREDIT CARD 01046B Printed: Monday, September 30, 2019 11:24 AM 1 of 1 YSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 e: 09/30/2019 11:23:36 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********0571 K TRAN AMOUNT: $198.17 APPROVAL CD: 01046B RECORD it: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy 1-Ittl,e • re-rtrxr11,1-1 a, 1 1-11/.1.0/1 Qrlt or-1m Alirti a I NArsrrhant/trancartiem rin9dienntrhhApfhod=nri 9/10/?(11 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/30/2019 11:23:36 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********0571 K TRAM AMOUNT: $198.17 APPROVAL CD: 010468 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy Imps ://www. myvirtualmerchant comNirtualMerchant/transaction.do?dispatchMethod—pri... 9/30/20 19 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 4 7./.54 -0 /// PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: ,Special Instructions: . 613 Date Wanted: 7 a.m. Requester: / Phone No: Approved per applicable codes. 11 Corrections required prior to approval. COMMENTS: PLA) v act--- Fi REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection. NSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project" fir ?Uir.te a Inspection: Type Inspection: P , Address: : k� Special Instructions; ©ate Wanted: // Requester: , f Phone : ( Ofa) 4 05 - eiZ --%) .. ved per applicabte codes. Corrections re o approval. COMMENTS: IOW 'Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calk to schedule reinspection. • Two Handle Kitchen Faucet Product Features • Stainless disc cartridges • Metal lever handles • 3 hole installation • 100% factory pressure tested • 1.8 gpm max. flow rate • Max deck thickness: 7/8" • Meets ANSI: A112.18.1M • NSF-61 compliant • ADA Compliant Model Numbers PFXC6880LSCP Polished chrome PFXC6880LSBN Brushed nickel Available Parts PFX4LAVEXT Thick deck mounting kit Warranty and Codes This product comes complete with installation, operating, care and maintenance instructio This PROFLO faucet carries a limited life warranty when installed in residential applications. The warranty is five years in commercia applications. This product meets ANSI: A112.18.1M. Compliant with lead content requiremen California AB 1953. Product Specifications PFXC688OLSCP (-5 EiV'ED CITY OF TUKWILA SEP 3 0 2019 PERMIT CENTER `All measurements are nominal. Please verify before actual installation. Distributed Exclusively by Ferguson and Is ley Ca o141 © 2015 Ferguson Enterprises, Inc. 0315 24947 Bealeton Stainless Steel Sinks Product Features • 20 gauge stainless steel • Self -rimming • Available with 3 faucet holes • Sink clips included • Overall size 17" X 22" • Bowl size 14" X 15-7/8" • Bowl depth:7" • Drain diameter: 3-1/2" • Minimum cabinet size: 20" • Under spray coating and pads for sound deadening and insulation Model Numbers PFSR172273A 17X22 3H 7.0 20 GA 1B SS SINK Warranty and Codes This PROFLO stainless steel sink carries a limited lifetime warranty. In an effort to continually improve our products, we will make design changes from time to time. We reserve the right to ship newly designed product to fill any order unless it is agreed in writing to do otherwise. These products meet or exceed ASME/ANSI A112.19.3m. PFSR172273A Product Specifications All measurements are nominal. Please verify before actuakinstallation. © 2017 Ferguson Enterprises, Inc. All Rights Reserved Distributed Exclusively by Ferguson and Wolseley Canada CAP 12/2017 Food Waste Disposers insinkera or a aer Di ensions Dishwasher Drain Connection 4— 65/ie"-0. • Distance from bot om of sink 10 center line of disposer outlet. Add 1/2" when stainless steel sinks are used, • Length of tailpipe ram center line of disposer outlet to end of tailpipe. NOTE: Plumb waste line to prevent standing water in disposer motor housing. Job Specifications Submittal Sheet Specifications This popular model offers the following Type of Feed features and benefits: • 1/2 Horsepower Heavy Duty Motor (Quiet Dura-Drive°' Induction Motor) • 2-Year We Come To You in -Home Parts And Labor Service Warranty • Rugged Galvanized Steel Construction (For Disposer Durability) • Space -Saving Compact Design Sample Specification Food Waste Disposer(s) shall be InSinkErator Badgers' 5, continuous feed, with 1/2 H.P. motor, galvanized steel grinding elements with two stainless steel 360° swivel lugs. Self-service wrench. Warranty: 2-Year parts and in -home service. The complete InSinkErator warranty is included in the Care & Use Booklet packed with each unit. PSC Mit Paps sec 000e060 Continuous On/Off Control Wall Switch Motor Single Phase HP Volts 1/2 120 HZ 60 RPM 1725 Amp. (Avg. ad 6.9 Time Rating Intermittent Lubrication Permanently Lubricated Upper & Lower Bearings Shipping Weight (Approx,) 14 lbs. Unit Finish Waterborne Grey Enamel Overall Height 12-5/8" Grind Chamber Capacity 26 oz Motor Protection Manual Reset Overload Average Water Usage Approx.1 Gallon per Person Per Day Average Electrical Usage 3-4 KWh per Year Drain 1-1/2" Cushioned Connection Slip Joint Dishwasher Drain Connection 1 Yes Food waste disposers can provide en environmentally responsible alternative to •• transporting food waste to landfills. And they can help reduce greenhouse gas • emissions. At capable wastewater treatment plants, food waste can be recycled o produce renewable energy. Additionally, capable wastewater treatment plants can process food waste into fertilizer. (Check the plant in your area,) • • • • • • • • • • • • • 1-800-558-5700 www.insinkeratorcom EMERSON Appliance Solutions The Emerson logo as a trademark and service mark of Emerson Electric Co. The mounting collar configuration is a trademark of Emerson Electric Co, InSinkErator may make improvements andior changes in the apeoficatwns at any time, in its sole discretion, without notice or obligation and further seserve5 the naht to change .ar discontinue models. H714-101-02-02 Printed in U.S.A. s' 2010 ln5inkErator, :nS•nkErator :5 a division of Emerson Electric Co. All hoots Reserved. ICE MAKER OUTLET BOX }) 696 SERIES SPECIFICATION Sioux Chief 696 series supply 0xBoxTM shall be used where necessary in residential or commercial plumbing supply systems. Access box can be secured directly to vertical stud or between studs using galvanized bracket. Supply line can be installed from above or below. Arrester variations can be installed with arrester at any angle. Unit shall be available with 1/4-turn valves. Metal support bracket shall install into top/bottom tracks of box. Outlet connection shall be generally 1/4". Outlet connections should generally be provided with a test/tamper-resistant cap. Every unit shall include a debris cover for protection during rough -in. Valves will be plated. MATERIALS Valve body: no -lead brass" Valve shank: no -lead brass'/copper/PPSU/CPVC, 304SS grip ring Outlet box/frame: ABS Arrester body: stainless steel, C69300 NL brass" Arrester piston: GFPP with EPDM o-rings Bracket: galvanized steel CERTIFICATIONS/APPROVALS NSF-372 compliant, IAPMO listed box and valve, ASSE 1010 arrester* Valve meets ASME A112.18.1 VALVE/ARRESTER WORKING LIMITS Max working temperature: 200°F Max air/water testing & working pressure: 150 PSIG DIMENSIONS A: Frame width B: Frame height C: Frame opening width D: Frame opening height E: Rough -in box inner width F: Rough -in box overall depth G: Rough -in box inner height H: Supply connection I: Outlet connection J: Bracket length Create Item Number ARRESTER A 0 = No arrester 1 = With arrester* 53/4" 71/4" 33/8" 51/8" 4" 31/2' 51/2" 1/2" nominal 1/4" compression 18" 696-GlOAOR e.g. 696-G1010MF: Ice maker SUPPLY CONNECTION B C = '6" Male CPVC ▪ M = ½ M1P/F.SWT P = 1/2" Male sweat/press/push V = 1/2" Vega' PureFlow* PEX ▪ W = 1/2" PEX F1960 Grip'm ▪ X = "6" PEX F1807/F2159 Crirnpr" OxBoxmi ITEM # SUBMITTED ' JOB NAME LOCATION ENGINEER CONTRACTOR PO# TAG 696-G1010XF 696-G1000WR ‘,„) .... ........... supply box with no lead FSWT valve with arrester and frame FRAME PACKAGING C F = Standard pack (supply box, frame, bracket, debris cover) FPK4 = Display box (supply box, frame, bracket, debris cover) FS = Standard pack w/6-ft. braided supply line R = Rough -in pack (supply box, bracket, debris cover) 020 Available Separately: 696-1F: frame only 696-SC1: frame insert w/ hose knockout 696-EX: frame extension Sioux Chief Manufacturing Company P: 1,800,821.3944 F: 1.800.758.5950 1 www.siouxchief.com -19 Tralatiry eArinD rlouy .1=11.4 d VZ7 d CZ; PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0141 DATE: 10/01/2019 PROJECT NAME: PROVIDENCE SITE ADDRESS: 2811 S 102ND ST 210 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Pr NAA, Building Division 1?..,Wwoms Fire Prevention Structural P Ez] PRELIMINARY REVIEW: Not Applicable LJ (no approval/review required) Planning Division r Permit Coordinator DATE: 10/01/19 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 10/29/2019 Approved Approved with Conditions E Corrections Required Denied (corrections entered in Reviews)(ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 Flume 1panol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries [Search L&I A-Z.Index Help My [hi Workplace Rights Trades & Licensing WESTERN MECH CONTRACTORS INC Owner or tradesperson Principals WELLS, MATTHEW P, PRESIDENT KACSO, OTTO, PRESIDENT (End: 12/01/2011) KACSO, TRACI, SECRETARY (End: 12/02/2011) Doing business as WESTERN MECH CONTRACTORS INC WA UBI No. 602 783 210 7018 SOUTH 220TH STREET KENT, WA 98032 253-946-9544 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. WESTEMC919QL Effective — expiration 11/13/2009— 01/15/2020 Bond Old Republic Surety Co Bond account no. w150340148 $12,000.00 Received by L&I Effective date 03/13/2019 07/02/2019 Expiration date Until Canceled International Fidelity Ins Co $12,000.00 Bond account no. SAIFSU0726894 Received by L&I Effective date 07/03/2018 07/02/2018 Expiration date Until Canceled Bond history Insurance Federated Mutual Ins Co Policy no. $1,000,000,00 Help us improve 3630944 Received by L&I Effective date 08/26/2019 08/28/2019 Expiration date 08/28/2020 Insurance history Savings No savings accour.:s during the previous 6 year period. Lawsuits against tte bond or savings Cause no. r 18-2-04326-3KNT Complaint filed by GREEN FIELD SERVICES INC Complaint date 02/21/2018 Open Complaint against bond(s) or savings 9916171 Complaint amount 569,551.79 L&I Tax debts No L&I tax debts a a recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violatio..s during the previous 6 year period. Certifications & Endorsements OMWBE Certificaty, ns No active certificaticis exist for this business. Apprentice Trainin;:Agent Registered training ..gent. Check their eligible programs and occupations. Workers' cc mp Ic. Do you know if the %Hsiness has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has nuitlple workers' comp accounts. Active accounts L&I Account ID 148,587-00 ni Account is current. Doing business as WESTERN MECHf .1ICAL CONTRACTORS Estimated workers reported Quarter 2 of Year : 119 "31 to 50 Workers" L&I account contact T3 / FEARAED FEI OZE (360)902-4797 - Email: FERH235@Ini.wa.gov Track this contractor 0 Public Wor...s Requirements Verify the contractor is eligible to perform work on public works projects. Required Training- Effective July 1, 2019 Exempt from this re:;uirement. Contractor Strikes No strikes have be an issued against this contractor. Contractors not a )wed to bid No debarments ht e been issued against this contractor. Workplace safety and health No inspections duri j the previous 6 year period. Help us improve 3 4 5 8 7 8 10 REFERENCE SYMBOLS ABBREVIATIONS PROJECT DIRECTORY DRAWING INDEX 11% ADDITIONAL ABBREVIATIONS ARE DEFINED IN LEGENDS THROUGHOUT AC ASPHALTIC CONCRETE D ACC ACCESSIBLE NCL ACP ACOUSTICAL CEILING PANEL NFO ACST ACOUSTICAL NSUL AD AREA DRAIN NT ADDM ADDENDUM WD ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR JAN AHU AIR HANDLING UNIT JT ALT ALTERNATE ALUM ALUMINUM KIT ANOD ANODIZED APPROX APPROXIMATE L APT APARTMENT LAM ARCH ARCHITECT, ARCHITECTURAL LAU AUTO AUTOMATIC LAV AV AUDIO VISUAL LT AWP ACOUSTICAL WALL PANEL(S) LTG 88 BULLETIN BOARD MAS 8D BOARD MAIL BLDG BUILDING MAX BLKG BLOCKING MECH BO BOTTOM OF MED BOT BOTTOM MEMB BRG BEARING MEZZ BRZ BRONZE MGT BSMT BASEMENT MFL BUR BUILT UP ROOFING MFR MH CAB CABINET MIN CB CATCH BASIN MISC CEM CEMENT, CEMENTITIOUS MO CER CERAMIC MS CG CORNER GUARD MTD CH COAT HOOK MTL CI CAST IRON MVBL CJ CONTROL JOINT CIP CAST -IN -PLACE N CL CENTERLINE NIC CLG CEILING NO CLO CLOSET NOM CLR CLEAR NTS CMU CONCRETE MASONRY UNIT OC CO CLEAN OUT, CASED OPENING OH COL COLUMN OD COMM COMMUNICATION CONC CONCRETE OPNG CONN CONNECTION, CONNECT OPP CONSTR CONSTRUCTION ORD CONT CONTINUOUS, CONTINUE OTS CCAR RIDOR CPPTT CARPET PBD CTR CENTER CSWK CASEWORK PRCST CU CUBIC PD PERP D DEEP, DEPTH PLAM DBL DOUBLE PLAS DEMO DEMOLISH, DEMOLITION PLYWD DET DETAIL PNL DF DRINKING FOUNTAIN PL DIA DIAMETER PR DOG DIAGONAL, DIAGRAM PRKG DIM DIMENSION PROP DN DIVIDE, DIVISION PT DMPF DAMPPROOF, DAMPPROOFING PTN DN DOWN DR DOOR, DRESSING ROOM R DS DOWNSPOUT RCP DW DISHWASHER RD DWG DRAWING REF DWR DRAWER REF REINF E EAST READ EIFS EXTERIOR INSULATION AND REV FINISH SYSTEM RFG EJ EXPANSION JOINT ELEVATION RM EL RO ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR ENCL ENCLOSE, ENCLOSURE S EP ELECTRIC PANEL SCHED EQ EQUAL SD EQUIP EQUIPMENT SECT ESCAL ESCALATOR SG EXH EXHAUST SGL EXP EXPANSION, EXPOSED SHT EXIST EXISTING SHTHG SIM FA FIRE ALARM SPEC FCIO FURNISHED BY CONTRACTOR/ SPKLR INSTALLED BY OWNER SPKR FD FLOOR DRAIN SQ FDC FIRE DEPARTMENT SS SST CONNECTION STC FDTN FOUNDATION FE FIRE EXTINGUISHER STD FEC FIRE EXTINGUISHER STL CABINET STOR FH FIRE HYDRANT STRUCT FHC FIRE HOSE CABINET SUSP FIG T FIN FINISH, FINISHED T&G FLEX FLEXIBLE TEL FLR FLOOR, FLOORING TEMP FLUOR FLUORESCENT TER FO FACE OF, FINISHED OPENING THK FDIC FURNISHED BYOWNER/ TO INSTALLED CBCONTRACTOR TSTAT FP FIRE PROTECTION, FIREPROOF TV FR FRAME, FIRE RATED FRMG FRAMING TYP FRT FIRE RETARDANT TREATED U/C FT FOOT, FEET UGND FTG FOOTING UNFIN FUT FUTURE FVC FIRE HOSE VALVE CABINET LION FWC FABRIC WALL COVERING FWP FABRIC WRAPPED PANEL(S) VERT VEST GA GAGE VNR GALV GALVANIZED VR GEN GENERAL, GENERATOR VWC GFRC GLASS -FIBER W REINFORCED CONCRETE GFRG GLASS -FIBER Al REINFORCED GYPSUM W/O GFRP GLASS -FIBER WC REINFORCED PLASTIC WD GL GLASS WH GYP GYPSUM WP GYP BD GYPSUM BOARD WR H HIGH WT HB HOSE BIBS WWF HCWD HOLLOW CORE WOOD HD HAND DRYER XFMR HDBD HARDBOARD HDW HARDWARE HDWD HARDWOOD HM HOLLOW METAL HO HOLD OPEN HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING, VENTILATING, AND AIR CONDITIONING THE DRAWING SET. NSIDE DIAMETER NCLUDE, INCLUDING NFORMATION NSULATE, INSULATION NTERIOR NDIRECT WASTE DRAIN JANITOR JOINT KITCHEN LONG LAMINATE, LAMINATED LAUNDRY LAVATORY LIGHT LIGHTING MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM MEMBRANE MEZZANINE MANAGEMENT MAXIMUM FORESEEABLE LOSS MANUFACTURE, MANUFACTURE MANHOLE MINIMUM, MINUTE MISCELLANEOUS MASONRY OPENING MOP SINK MOUNTED METAL MOVABLE NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OVERHEAD OUTSIDE DIAMETER OPENING OPPOSITE OVERFLOW ROOF DRAIN OPEN TO STRUCTURE ABOVE PARTICLEBOARD PRECAST PLANTER DRAIN PERPENDICULAR PLASTIC LAMINATE PLASTER PLYWOOD PANEL PROPERTY LINE PAIR PARKING PROPERTY PAINT, POINT, PRESSURE TREATED PARTITION RADIUS, RISER REFLECTED CEILING PLAN ROOF DRAIN, ROAD REFER TO, REFERENCE REFRIGERATOR ED, REINFORCING REQUIRED REVISED, REVISION ROOFING ROOM ROUG H OPENINGRT RIGHT ADR E N SP H, L SOUTH SOUTUT SRDRE SCHEDULE STORM DRAIN SECTION SAFETY GLASS SINGLE SHEET SHEATHING SIMILAR SPECIFICATION SPRINKLER SPEAKER SQUARE SERVICE SINK STEEL ESS STAINLESS LPLUMBING SOUND MISSION CLASS STANDARD STEEL STORAGE STRUCTURAL SUSPENDED TREAD, TEMPERED TONGUE AND GROOVE TELEPHONE TEMPERATURE, TEMPORARY TERRAllO THICK, THICKNESS TOP OF THERMOSTAT TELEVISION TYPICAL UNDER COUNTER UNDERGROUND UNFINISHED UNLESS OTHERWISE NOTED VERTICAL VESTIBULE VENEER VAPOR RETARDER VINYL WALLCOVERING WEST, WIDE WITH WITHOUT WATER CLOSET, WALLCOVERING WOOD WALL HYDRANT WEATHERPROOF, WATERPROOF, WATERPROOFING, WORK POINT WATER RESISTANT WEIGHT WELDED WIRE FABRIC TRANSFORMER ARCHITECT /DESIGNER: PLUMBING ENGINEER: A-001 COVER SHEET AND PROJECT INFORMATION A-002 NOTES AND SPECIFICATIONS A-003 SITE PLAN A-005 LIFE SAFETY PLAN A-100 FLOOR DEMOLITION PLAN A-101 FLOOR CONSTRUCTION PLAN A-102 FLOOR REFLECTED CEILING PLAN A-103 FLOOR FURNITURE PLAN - NEW A-601 DOOR, FINISH, DEVICE MOUNTING SCHEDULES AND DETAILS A-801 PARTITION TYPES AND CEILING DETAILS 43 0120 BUILDING SECTION INDICATOR VP WALL SECTION INDICATOR SABEY ARCHITECTURE TBD -Design Build by G.C. 12201 TUKWILA INTL BLVD, FOURTH FLOOR SEATTLE, WA 98168 TEL: (206) 281.8700 FAX: (206) 282-9951 MECHANICAL ENGINEER: 413 ATTN: TOM SPADER TBD - Design Build by G.C. EMAIL: TOMS@SABEY.COM BUILDING OWNER: ELECTRICAL ENGINEER: � �` 1 1 1 ENLARGED DETAIL INDICATOR , _ _ i 40) SECTION DETAIL INDICATOR RIVERFRONT TECHNICAL PARK, LLC TBD - Design Build by G.C. 12201 TUKWILA INTL BLVD, FOURTH FLOOR SEATTLE, WA98168 TEL: (206)281.8700 FAX: (206)282-9951 FIRE I LIFE SAFETY ENGINEER: XX A-XXX EXTERIOR ELEVATION INDICATOR � ^^ \ © ATTN: DEBBIE SABEY TBD - Design Build by G.C. EMAIL: DEBBIES@SABEY.COM GENERAL CONTRACTOR: A-XXX i A-000 © SABEY CONSTRUCTION 12201 TUKWILA INTL BLVD, FOURTH FLOOR PLUMBING, MECHANICAL, ELECTRICAL, SEATTLE, WA 98168 LIFE SAFETY PERMITS UNDER SEPERATE TEL: (206) 281-8700 SUBMITTALS. FAX: (206) 282-9951 ATTN: PAUL SWANSON EMAIL: PAULS@SABEY.COM INTERIOR ELEVATION INDICATOR MATCH LINE SEE XXIA-XXX MATCH LINE INDICATOR DRAWING REVISION INDICATOR X.X 9 EXISTING COLUMN GRIDLINE INDICATOR I .X — — X.X S— NEW COLUMN GRIDLINE INDICATOR I BUILDING ADDRESS VICINITY MAP RIVERFRONT TECHNICAL PARK 2811 S. 102ND STREET, SUITE 210 SEATTLE, WA 98168 `z ''`, o ,�o�� 9 „ •.,,,L,=, ,,, ' a,P1,p Ae:,,.. 40 DATUM INDICATOR OR WORK POINT EL XXX.XX EL. XXX'•XA' SPOT ELEVATION INDICATOR ROOM NAME XXXX ROOM INDICATOR <E 1 XXXXX > EQUIPMENT INDICATOR �[ SCOPE OF WORK <X1 XXXXX> FIXTURE INDICATOR <F I XXXXX > FURNITURE INDICATOR <GI X 000(> GRAPHIC/SIGNAGE INDICATOR INTERIOR TENANT IMPROVEMENT OF EXISTING SHELL SPACE SUITE 210 IN RIVERFRONT TECHINICAL PARK BUILDING. THE WORK INCLUDES NON -LOAD BEARING WALLS AND ARCHITECTURAL FINISHES. MISCELLANEOUS INDICATORS XXJ, (DOOR) OPENING INDICATOR (F 1 )00011) FINISH INDICATOR 1 WINDOW INDICATOR (XX'-XX" AFF ) CEILING HEIGHT INDICATOR MATERIAL (PER FINISH LEGEND) FINISH (PER FINISH LEGEND) CODE AND BUILDING INFORMATION XX I XX ( XX "MAT 1 F-XXX AFF WALL TYPE INDICATOR XX-XX" HEIGHT CEILING HEIGHT/MATERIAL/FINISH INDICATOR PROJECT NAME: PROVIDENCE SUITE 210 EXPANSION SITE ZONING: MIC/H KING COUNTY ASSESSOR'S PARCEL NUMBERS: 042304-9190 APPLICABLE CODES: Q FE MOUNTED TO WALL 0> KEYNOTE WITH BRACKET FEC IN WALL -MOUNTED II CABINET FIRE EXTINGUISHERS EXISTING TO REMAIN (SHOWN SHADED) = p EXISTING TO BE DEMOLISHED L (SHOWN DASHED) BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (WAC 51-50) MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE (WAC 51-52) CODE: 2015 UNIFORM PLUMBING CODE (WAC 51-56 ) ELECTRICAL CODE: 2015 INTERNATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE (WAC 51.11C) FIRE CODE: 2015 INTERNATIONAL FIRE CODE (WAC 51-54A) FUEL GAS CODE: 2015 INTERNATIONAL FUEL GAS CODE ACCESSIBILITY CODES: WASHINGTON STATE ACCESSIBILITY CODE (WAC 51-50) USE GROUP AND OCCUPANCY: (PROPERTY) LEGAL DESCRIPTION PARTITION) (NON -RATED — - —' --- (1-HOUR RATED PARTITION) RATED PARTITION) LEGAL DESCRIPTION: PORTION OF SE 1/4 - BEGIN SW CORNER OF GOV LOT 111N SE 1l4 OF SECTION 04 23 Q4 TH S 89-22-06 E 988.27 TO INTERSECTION WITH N LINE OF S 460 FT OF GOV LOT 11 &NELY MARGIN OF PRIMARY STATE HIGHWAY NO 1 TH N 14-45-08 W 689.81 FOOT SEATTLE TRANSMISSION LINE TH N 14-45.08 W 22.70 FT TAP OF SPIRAL CURVATURE TH CONTINUING ALONG NELY MARGIN THE CHORD BEARING N 15.07.51 W 152.94 FT TAP OF SIMPLE CURVATURE TH ALONG NE MARGIN NWLY 340.67 FT ALONG ARC OF RADIUS OF 3970 FT RADIUS POINT BEARINGS 74-07-22 W THRU C/A OF 04.5500 TH CONTINUING ALONG SAID NELY MARGIN N 11-24-57 BEGINNING TH N 11.24-57 E 61.40 FT TAP OF SIMPLE CURVE TH CONTINUING ALONG SAID NELY MARGIN NWLY 191.94 FT ALONG ARC LEFT RADIUS OF 4190 PT RADIUS POINT BEARING S 64-42-23 W THRU C/A OPO2-37-29 TH N 27-01.05E 8978 FT TH N 48-11-59 E 442.51 S 48.05 28 W 406,87 FT TH N 41-52-51 W 627.47 FT TH S 4811 44 W 218.98 FT NIL TO POB - PORTIONS OF LOTS 1 & 2 OF K C SHORT 9006050697 - - LOT 1OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NG L96.0002 RECORDING NO 9707090733 FT TH N 14 45 08 W 477.09 FT FT TO SWLY MARGIN OF 200 ALONG SPIRAL CURVE TO LEFT NON TANGENT CURVE TO LEFT E 327.11 FT TO POINT OF OF NON TANGENT CURVE TO FT TH S 41-52.02E 881.11 FT TH PLAT NO 588023 RECORDING NO — - - — - - — (2-HOUR HOUR RATED PARTITION) (3 RATED PARTITION) - - - - (4-HOUR SMOKE BARRIER NEW .—} TYPE OF WORK 5 N 5 S SMOKE PARTITION PARTITIONS SEPARATE EPA LJRAI TED PERMIT Electr call ❑ Plumbing Gas Piping City of Tukwila BUILDING DIVISION RCP SYMBOLS NO CHANGE TO OCCUPANCY GROUP OCCUPANCY: 8 {OFFICE) EXISTING TYPE OF CONSTRUCTION: CEILING -MOUNTED El 2'X2' FLUORESCENT LIGHT ICC CONSTRUCTION TYPE VB NUMBER OF STORIES: HVAC DIFFUSERS ® (SIZE AND TYPE PER MECHANICAL DRAWINGS) ® STORIES ABOVE GRADE PLANE: 2 STORIES BELOW GRADE PLANE: 0 SEISMIC DESIGN CATEGORY: 2'X4'IFLUORESCENT LIGHT GENERAL NOTES •CEILING -MOUNTED ( 1'X4' FLUORESCENT LIGHT t t HVAC RETURNS/EXHAUSTS ® ® (SIZE AND TYPE PER MECHANICAL DRAWINGS) CEILING -MOUNTED HVAC ITEMS D PROPOSED AREA OF REMODEL: (HIDDEN) CEILING MOUNTED 1. DO NOT SCALE THE DRAWINGS. 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK. 3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. � -�.r- �(�}(�I��1 +.. ,., �,� .•« 4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES,UNLESS P ,,4; OTHERWISE INDICATED. of 5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE 1 0 20 R LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS SIX INCHES FROM THE FACE OF THE NEARBY WALL UNLESS OTHERWISE INDICATED, ALL OTHER DOORS AND CASED OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL INTERSECTONS. Cityof T U sj(�i'°aDi, li(a 6. ITEMS INDICATED AS BIDDER DESIGNED SHALL BE DESIGNED AND ENGIIIEERED 8Y THE STRIP FLUORESCENT LIGHT (EXPOSED) CEILING -MOUNTED 1— — —1 12,893 SF OF PROJECT AREA CORE AND SHELL FIRE RATINGS: STRIP FLUORESCENT LIGHT WALL -MOUNTED I '" I STRIP FLUORESCENT LIGHT AS EXISTING - NO CHANGE INTERIOR FINISHES: 0DOWNLIGHT p ACCENT DOWNLIGHT O> WALL -WASHER DOWNLIGHT SCONCE -TYPE 6 (WALL -MOUNTED) LIGHT ® CEILING -MOUNTED EXIT LIGHT 6 WALL -MOUNTED EXIT LIGHT STANDARD LIGHT FIXTURES PER TABLE 803.9 CLASS C FINISHES WITH EXCEPTION OF EXITS WHERE CLASS B IS USED MEANS OF EGRESS: CEILING MOUNTED ACCESS PANEL SEE A-005 • LIFE SAFETY PLAN PARKING: NO CHANGE TO PARKING IS PROPOSED IN CONJUNCTION WITH THE PROJECT. PARKING DEMANDS AS A RESULT OF COMMERCIAL TI ARE MET BY EXISTING SITE PARKING FACILITIES. ALL ACCESSIBLE SITE FEATURES AND PARKING STALLS ARE PROVIDED PER THE BUILDING LANDLORD, CEILING -MOUNTED FIRE SPRINKLER CEILING -MOUNTED SPEAKER CONTRACTOR AND/OR SUBCONTRACTOR IN COMPLIANCE WITH APPLIC 8LE LEGAL REQUIREMENTS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSISBY A QUALIFIED PROFESSIONAL ENGINEER, USING PERFORMANCE AND DESIGN CRITERA INDICATED. — ID' ` El SAkBEY Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 Irlt,°V of+H 1 ') PROVIDENCE SUITE 210 EXPANSION RIVERFRONT TECHNICAL PARK 2811 S 102ND ST, SUITE 210 TULWILA, WA 98168 SEP 3 0 2019 1 9/13/19 ISSUED FOR CONSTRUCTION MARK 1 DATE I DESCRIPTION PROGRESS DATE: 9/16/19 DRAWN BY: AK CHECKED BY: TS APPROVED BY: KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. COVER SHEET AND PROJECT INFORMATION 2 6 7 10 I 02 CD 0 0 0 OFFICE OFFICE AREA 4'. 11" NEW BREAK AREA 09 004, NEW QUIET ROOM 10 I OFFICE 11'•.=======-4] '1=11'111'11-11,-, • NEW SUITE 210 01 14,517 RSF 12,893 USF STORAGE 111 -111 11 11 I ; OFF. ELEC. SRAREDSYSUITE SOO OFFICE HUDDLE ROOM 111-- 11 11 . , E3 I I 11 EXISTING I I EXIT STAIR I l 0 SECOND FLOOR - PARTIAL OFFICE CONSTRUCTION PLAN 1/8" = 1,0" St"ope- waste : water 1,1 ra: Ir,tail 2 new 1,te atre,stors per -11,onnect re ex,sting r-r,"er st.,ppIy behind ; .111,11 & 1,1,1'0 2 new ,nks ',Iva. mew faucels IrstalI 2 r,ew :badger exIsting ana aLThwas1lers, FLOOR PLAN NOTES: 1, REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5, PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE-RETARDENT TREATED WOOD. 7. UON, ALL PARTITIONS 8. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 6" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD, 9. FOR TYPICAL DEVICE MOUNTING HEIGHTS, SEE 3 / A-601 1.1,1.1 FLOOR PLAN KEYNOTES: / INFILL EXISTING OPENING - MATCH EXISTING MTL. STUD/ GWB WALL ASSEMBLY A . NEW SOLID CORE WOOD DOOR - IF POSSIBLE, REUSE FROM BUILDING STOCK. BUILD NEW ACOUSTICAL INSULATED WALLS TO 6" ABOVE ACOUSTICAL CEILING, PAINT, AND INSTALL NEW RUBBER BASE. 0 VERIFY SWITCHING AND EXTINGUISHER CABINET LOCATIONS, RELOCATE AS NEEDED. WOOD DOOR WITH GLASS PANEL - 2 X 6 GLASS WITH PRIVACY FILM. PATCH AND pAINT ALL WALLS - VERIFY WITH TENANT. NOTE: SEE SEPARATE PAINT DRAWING. TOUCH UP FINISH ON DOORS AND FRAMES AS NEEDED. 0 REBALANCE HVAC. 191 PROVIDE NE OCKING HARDWARE AND CARD READER ACCESS - VERIFY WITH TENANT. 41) EXISTING CARPET 0 REMAI PATC AND CLE N CARP 0 NEWCASEWORK ooTREKRUPpPsEIATBLOWERS). ACKSPLASH: NEVAMAR/ ARMORED PROTECTION/ CHARCOAL FUSION FN6001, TEXTURED WHITE INTERIOR MELAMINR COLOR CASEWORK: NEVAMAR/ ARMORED PROTECTION/ BETHANY BEIGE S2069T/ TEXTURED WHITE INTERIOR MELAMINE COLOR 0 REUSE EXISTING CASEWORK (UPPERS & LOWERS) RELAMINATE: COUNTERTOPS AND BACKSPLASH: NEVAMAR/ ARMORED PROTECTION/ CHARCOAL FUSION FN6001, TEXTURED WHITE INTERIOR MELAMINR COLOR CASEWORK NEVAMAR/ ARMORED PROTECTION/ BETHANY BEIGE S2069T/ TEXTURED WHITE INTERIOR MELAMINE COLOR - MATCH TENANT STANDARDS. - NEW SINK/ DISHWASHER/ REFRIGERATOR AND OTHER APPLIANCES. • EXISTING PLUMBING TO REMAIN, 0, VERIFY THE FORCE FOR PUSHING/ PULLING THE DOOR THE FORCE SHALL BE 5.0 POUNDS (22.2 N) _MAXIMUM 11) PROVIDE TWO NEW GARBAGE DISPOSALS, 0 PROVIDE NEW MOISTURE SENSORS UNDER THE SINK. ePROVIDE NEW OFFICE SIGNAGES - VERIFY WITH TENANT. PATCH AND WAX EXISTING VCT FLOORING IN THE BREAK AREA. 0 1/4" = 11.0" ELEVATION C CONSTRUCTION LEGEND: F614-0 141 EXISTING TO REMAIN (SHOWN SHADED) EXISTING TO BE DEMOLISHED (SHOWN DASHED) 1.....1111.1). NEW CONSTRUCTION CODE CO'-nJ,,,i,ICE AP) OCT 0 7 2019 City of Tukvaa 1LD! DiV,sioN SABEY Architecture 12201 Tukwila IntBlvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com PROVIDENCE SUITE 210 EXPANSION RIVERFRONT TECHNICAL PARK 2811 S 102ND ST, SUITE 210 TULWILA, WA 98168 SEP 3 0 2019 1 9/13/19 ISSUED FOR CONSTRUCTION MARK I DATE I DESCRIPTION PROGRESS DATE: 9/16/19 DRAWN BY: AK CHECKED BY: TS APPROVED BY: KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same rnay not be duplicated, used or disclosed without the written consent of the Sabey Corporation. FLOOR CONSTRUCTION PLAN A-101