HomeMy WebLinkAboutPermit PG19-0156 - CELLNETIX - NEW LAVATORY, WATER CLOSET, KITCHEN AND LAB SINKS ETCCELLNETIX
12501 E MARGINAL WAY S
EXPIRED
08/23/2021
PGI 9-0156
Parcel No:
Address:
°~ xx ° Tukwila
w~ u v x oa
Department mfCommunity Development
63OUSouthoenterBoulevard, Suite #1DO
Tukwila, Washington gB1Q8
Phone:2O6'431']678
Inspection Request Line: 206-438'9350
Web site: http://www.TukwilaWA.gov
P0WW4B|PV P|plPWG PERMIT
7345600580
l25O1EMARGINAL WAY 5
Project Name: CELLNETIX
Permit Number: PG19-0156
Issue Date: 11/7/2019
Permit Expires On: 5/5/2020
Owner:
INTERNATIONAL GATEWAY EAST
Address: 12201TUKVV|LA|NTRNTNLBL4TH,
6EATTLE,WA, 98168
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
ROBERTF|X
5O053RDAVE I,IEATTLE,WA, 98134
N1[K|N5TRY[OLL[([ONSTKUCT0N)
PO8OX24567,5EATTLE,WA, 98134
K8[K|N[L942DVV
'''
Phone: (206)762-3311
Phone: (206)762'3311
Expiration Date: 3/16/2020
DESCRIPTION OFWORK:
INSTALL ONE NEW LAVATORY, ONE WATER CLOSET, 3 NEW KITCHEN SINKS, 15 LAB SINKS AND 4 EMERGENCY
EYEWASHING STATIONS. INCLUDES INSTALLATION OF A 2" AND A 4" REDUCED PRESSURE PRINCIPLE ASSY (RPPA)WATER DISTRICT 12S. Valuation cfWork: $271,470.00
Water District: lZS
Sewer District: VALLEY VIEW
Fees Collected: $760,55
Current Codes adopted bythe City ofTukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
National Electrical Code:
VVACities Electrical Code:
VVA[Z9O^468:
:
Permit Center Authorized
Signature-
05 21
05 21
_ "
Date: _ _/
| hearbycertify that | have read and examined this permit and know the same to betrue and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development p�Zmitand agree tnthe conditions attached tothis permit.
Signature:
This permit shall become null and void if the work isnot commenced within 18Odays for the date uf issuance or if
the work is suspended or abandoned for a period of 180 days from the last inspection,
PERMIT CONDITIONS:
1: ***PLUK4B|NG/GA3PIPING PERMIT [OND[DOmS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall betested and approved asrequired bythe Plumbing Code and
Fuel Gas Code. Tests shall beconducted inthe presence nfthe Plumbing Inspector. |tshall bethe duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work bready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision ismade toprotect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall beinsulated tominimum R'3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall beprotected bysteel nail plates not less than 18gauge.
9: Piping through concrete ormasonry walls shall not besubject toany load from building construction. No
plumbing piping shall bedirectly embedded inconcrete ormasonry,
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
inaccordance with the requirements ofthe building code.
11: Piping inthe ground shall belaid onafirm bed for its entire length. Trenches shall bebackfi||edinthin
layers totwelve inches above the top nf the piping with clean earth, which shall not contain stones,
boulders, cinder0||,frozen earth, orconstruction debris.
12: The issuance ofapermit orapproval ofplans and specifications shall not beconstrued tobeapermit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance ofthe jurisdiction,
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit,
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures inall residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
4O2ofWashington State Amendments
15: 'PUBLIC WORKS PERMIT COND|T0N5**p
16: Installation of Reduced pressure principle assembly (RPPA) requires a separate inspection from Public
Works; call (206) 433-0179 minimum 24 hours in advance to schedule. The applicant or contractor must
notify the Public Works Inspector at (206) 433-0179 upon commencement and completion of work at least
24hours |nadvance. All inspection requests for utility work must also bemade 24hours |nadvance,
17: The RPPA(s)shall beinstalled per manufacturer's specifications and tested byacertified tester.
18: Thereafter the RPPA(s) shall be tested annually at the property owner's expense & test report(s) shall be
forwarded toWater District #1ZS,346US148thSt, Suite 11lTukwila, VVA98I68,
phone(ZO6)Z42'9747;http://www.waterdistr\ctlZ5.com
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (2O6)43#-U35O
8084 GROUNDWORK
1900 PLUMBING FINAL
1600 PUBLIC WORKS FINAL
8005 KOUGH'|NPLUyWB|NG
CITY OF TUKW&)
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Gas Permit No. p6 1 OtS-co
Project No.
Date Application Accepted: 1 0-15'—I
Date Application Expires: t 3--)0
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 12501 East Marginal Way S
Tenant Name: Cellnetix
King Co Assessor's Tax No.: 7345600580
Suite Number:
PROPERTY OWNER
Name: International Gateway East
Address: 3716 S 126th St.
City: Tukwila State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Robert Fix
Address: 5005 3rd Ave S
City: Seattle State: WA
Zip: 98134
Phone: (206) 762-3311 Fax:
Email: permits@mckinstry.com
Floor: 1 & 2
New Tenant: EJ Yes 121..No
PLUMBING CONTRACTOR INFORMATION
Company Name: McKinstry Co. LLC
Address: 5005 3rd Ave S
City: Seattle State: WA Zip: 98134
Phone:
(206) 762-3311 Fax:
Contr Reg No.: MCKINCL942DW Exp Date: 03/16/2020
Tukwila Business License No.: BUS-0994320
Valuation of Project (contractor's bid price): $ 271,476
Scope of Work (please provide detailed information):
Install one new Lavatory, one Water Closet, 3 New Kitchen Sinks, 15 Lab Sinks and 4 Emergency Eye Washing stations.
118108-001
Building Use (per Intl Commercial Building Code) Commercial
(per Int'l Building Code): Business/Group B
Utility Purveyor: Water Seattle Public Utilities
Seattle Public Utilities
Sewer
HAApplications \ Forms -Applications On Line\ 2011 Applications\ Plumbing Permit Application Revised 8-9-1 I sloes
Revised: August 2011
Page 1 of 2
t'z'*41
Indicate type of plumbing fixtures and/ piping outlets being installed and the quantit,,Alow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
2
Shower, single head trap
Sinks
19
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
--,
2
CLECF121C—,
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor .4*in I,
S i A4 IL
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
t`A. 1titl LA
.
VA WES.
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER THO ZED A T:
c
Signature: p
Date: 10/15/2019
Print Name: Robert Fix Day Telephone: (206) 762-3311
Mailing Address: 5005 3rd Ave S
Seattle WA 98134
City State Zip
HAApplications \ Forms -Applications On Line \ 2011 ApplicationstPlumbing Permit Application Revised 8-9-11.docx
Revised August 2011
bh
Page 2 of 2
Receipt Number
R19757
DESCRIPTIONS
I
PermitTRAK
ACCOUNT
QUANTITY
PAID
$72.10
PG19-0156 Address: 12501 E MARGINAL WAY S
Apn: 7345600580
$7 . 0
Credit Card Fee
$2.10
Credit Card Fee
R000.369.908.00.00
0.00
$2.10
PLUMBING
$70.00
ADDITIONAL LAN REVIEW
TOTAL FEES PAID BY RECEIPT: R19757
R000.345.830.00.00
1.00
$70.00
$72.10
Date Paid: Friday, January 17, 2020
Paid By: ROBERT FIX
Pay Method: CREDIT CARD 046240
PrintedFriday. larniary 17. 2020 8:53 AM 1 of 1
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT
QUANTITY I PAID
PermitTRAK
.mk
760.55
PG19-0156 Address: 12501 E MARGINAL WAY S Apn: 7345600580
$760.55
Credit Card Fee
$22 15
Credit Card Fee
R000.369.908.00.00
0.00
22,15
PLUMBING
$710.00
PERMIT FEE
R000.322.100.00.00
0.00
$533.00
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0,00
.00
PLAN CHECK FEE
R000.322,103.00,00
0.00
42,00
TECHNOLOGY FEE
$28.40
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$28.40
TOTAL FEES PAID BY RECEIPT: R18819
$760.55
Date Paid: Tuesday, October 15, 2019
Paid By: ROBERT FIX
Pay Method: CREDIT CARD 038050
••••••••
Printed: Tuesday, October 15, 2019 8:20 AM 1 of 1
CO TUKwILA ETKAKIT
5208 SOUTH[ENTEK BLYD
TUKWZL4' WA 98188
206-433-1870
CITY OF TUKWILA
0017340000802374464500
Date: 01/17/2020 08:51:57 AM
CREDIT CARD SALE
VISA
CARD NUMBER: **********2506 x
TnAw AMOUNT: $72.10
xpPxOv»L [o: 045240
RECORD #: 080
cLsnx ID: szisv
X
{CARDHOLDER'S SIGNATUREJ
I AGREE TO PAY THE ABOVE TOTAL AMOUNT
ACCORDING TO THE CARD ISSUER AGREEMENT
(MERCHANT AGREEMENT IF CREDIT VOUCHER)
Thank you!
Merchant copy
CO TUKWILA ETRAKIT
6200 50UTHCENTER BLVQ
ToKWILA^ WA 98188
206'433'1870
CITY OF TVxwILx
Date: 01/17/2020 e8:51:57 mn
CREDIT CARD SALE
VISA
[4Ro NUMBER: **********2506 K
TRAN AMOUNT: $72.10
APPROVAL [D; 046240
RECORD #: 000
CLERK ID: slisa
Thank you!
Customer Copy
CO TUKWILA ETnAKIT
6200 SOVTHCENTER 8LVV
TVKWIL4, WA 98188
206'433'1870
CITY OF TUKWILA
Date: 18/15/2819 08:19:42 AM
CREDIT CARD SALE
VISA
CARD NUMBER: *****+***2506 K
TRAN AMOUNT: $700.55
APPROVAL [D: 038050
RECORD #: 000
CLERK ID: Bill
Thank you!
Customer Copy
Permit Inspections
City of Tukwila
Permit Number: PG19-0156
Applied: 10/15/2019 Approved: 11/6/2019
Issued: 11/7/2019 Finaled:
Status: ISSUED
Parent Permit:
Parent Project:
Description: CELLNETIX
Site Address: 12501 E MARGINAL WAY S
City, State Zip Code:TUKWILA, WA 98168
Applicant: CELLNETIX
Owner: INTERNATIONAL GATEWAY EAST
Contractor: MCKINSTRY CO LLC (CONSTRUCTION)
Details:
INSTALL ONE NEW LAVATORY, ONE WATER CLOSET, 3 NEW KITCHEN SINKS, 15 LAB SINKS AND 4 EMERGENCY EYEWASHING STATIONS.
INCLUDES INSTALLATION OF A2" AND A 4" REDUCED RESSURE PRINCIPLE ASSY (RPPA).
WATER DISTRICT125.
�®tCTIO S
SCHEDULED DATE
COMPLETED DATE
TYPE
INSPECTOR
RESULT
REMARKS
GROUNDWORK
Bill Centen
Notes:
PLUMBING FINAL
Bill Centen
Notes:
BACKFLOW - WATERI
Eric Pritchard
Notes:
12/30/2019 AM
12/30/2019
ROUGH -IN
PLUMBING
Bill Centen
PARTIAL
APPROVAL
134534
Notes:
12/30/2019 - BC
*Partial inspection on (2) 2" sanitary drains running through "Clean Room" These 2 drains are currently on test - ok
1/21/2020 AM
1/21/2020
ROUGH -IN
PLUMBING
Darrin Graham
PARTIAL
APPROVAL
562112
Notes:
Overhead Supply / In wall supply tested 100 psi
DWV overhead/in wall tested 5 psi
Level 2
1. Breakroom E237 and Coffee room E212 not part of approval
1/31/2020
1/31/2020
ROUGH -IN
PLUMBING
Lee Sipe
PARTIAL
APPROVAL
#3
Notes:
OK - rough -in Water/DWV for 5 sinks OK to cover.
rooms W216, W214, E212, E237.
Printed: Tuesday, 24 August, 2021
1 of 2
4.1,4••-
SUPERION
2/27/2020 AM
2/24/2020
GROUNDWORK
Darrin Graham
NOT APPROVED 1
273833
Notes:
4" waste grid line c.5 along 2 line
Sink rough in 4" riser
Called no answer, reschedule inspection.
3/9/2020 AM
3/9/2020
ROUGH -IN
PLUMBING
Darrin Graham
PARTIAL
APPROVAL
582539
Notes:
3/9/2020
Grid lines 2.8 along C.2 - C.5
Pump discharge line 1-1/2" - 2" Elevator shaft - approved
3/16/2020 AM
3/16/2020
ROUGH -IN
PLUMBING
Darrin Graham
APPROVED
40786
Notes:
West end DWV - test approved
Water is on test - ok
Grid line 4 A - F Line - ok
3/18/2020 AM
3/18/2020
GROUNDWORK
Darrin Graham
APPROVED
#7
Notes:
Rough in Plumbing
DWV Grid line 3.5 to 6.5, Grid A to C.5 Cast iron test gauge @ 5psi
5/14/2020 AM
5/14/2020
PLUMBING FINAL
Lee Sipe
PARTIAL
APPROVAL
50737
Notes:
P/A
Approved final pending final equipment installation.
5/15/2020 AM
5/15/2020
BACKFLOW - WATER
Eric Pritchard
NOT APPROVED
522349
Notes:
RPBA enclosure does not meet city standards for draining to daylight due to mechanical flap opening. Unable to inspect RPBA assembly because the
door won't open behind the curb.
8/20/2020 AM
8/21/2020
PLUMBING FINAL
Lee Sipe
PARTIAL
APPROVAL
491295
Notes:
need PW final.
8/24/2020 AM
8/24/2020
PUBLIC WORKS
FINAL
Eric Pritchard
NOT APPROVED
315850
Notes:
Hotbox door flap needs to be removed so that the RPPA can drain to daylight. Test cocks need to be plugged. I need a backflow test report from a
certified BAT.
8/27/2020 AM
8/27/2020
PUBLIC WORKS
FINAL
Eric Pritchard
APPROVED
105004
Notes:
OK to final.
Printed: Tuesday, 24 August, 2021
2 of 2
-4k
SUPER ION
&19- olSc)
•
•
tf)
4k,c
cr
OPERMIT COORD COPY°
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG19-0156 DATE: 10/15/2019
PROJECT NAME: CELLNETIX
SITE ADDRESS: 12501 EAST MARGINAL WAY S
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
AI Pod/
Building Division
ublic Works
II
Fire Prevention
Structural
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
Planning Division n
Permit Coordinator In
DATE: 10/15/19
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
DUE DATE: 11/12/2019
Approved with Conditions n
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
E
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg El Fire Ej Ping D PW El Staff Initials:
12/18/2013
EBM!T COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG19-0156
PROJECT NAME: CELLNETIX
SITE ADDRESS: 12501 E MARGINAL WAY S
Original Plan Submittal
Response to Correction Letter #
Revision #
DATE: 12/20/2019
before Permit Issued
X Revision # 1 after Permit Issued
DEPARTMENTS:
tri71g Division
JJO n
Public Works
Fire Prevention
Structural
n
E
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
REVIEWER'S INITIALS:
Planning Division
Permit Coordinator
DATE: 12/24/19
Structural Review Required
DATE:
•
LI
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
n
P
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 1/21/2020
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire LI Ping 0 PW
Staff Initials:
12/18/2013
It
PROJECT NAME: (1.etikt ET/ )( PERMIT NO: 4)6/ t 9 D 5 to
SITE ADDRESS: /9 5,0 fj/M2/10/14 (AYS.ORIGINAL ISSUE DATE: I ( - 7-0
REVISION LOG
REVISION
NO.
DATE RECEIVED
STAFF
INI IALS
ISSUED DATE
STAFF
INITIALS
19
/ I
ii — g-0A-
.
Summary of Revision:
eti-ropj-i rtkec.-61 • . `1 n_s igaaPjay-,
v
Received by: 1(Lii.kg4)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received b :
(please p
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: lutp://www.TukwilaW,
REV SI
SUBMITTAL.
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: 12, •2z)12-0(ci Plan Check/Permit Number:
• Response to Incomplete Letter #
O Response to Correction Letter #
Li Revision #
Revision #
before Permit is Issued
after Permit is Issued
Revision requested by a City Building Inspector or Plans Examiner
E] Deferred Submittal #
Project Name:
Project Address: t-AAza, W
Contact Person: 120EeCarr tX Phone Number: 9 I
Sez 2-45E:cyk 1rrE cxtaztpar*
1.2459()CS-7--,
Cet_Lkien V:
RECEIVED
CITY OF TUKWILP
DEC 2 0 2019
PERMIT CENTER
Summary of Revision:
Sheet Number(s):
"Cloud" or highlight all areas of evision including date of revision
Received at the City of Tukwila Permit Center by:
LI Entered in TRAKiT on
CAUsers\Kandace-PRAppData\LocaRMicrosoft WindowskNetCacheContent.Outlook\QESSISYWORevision Submittal Formdoc
Revised: August 2019
C
nstry
Ire Of Your Building
City of Tukwila
eie&Perm it
Reference: Permit # PG19-0156
Project Name: CELLNETIX
Project address: 12501 East Marginal Way S Tukwila, WA
Permit Revisions:
Dec. 18t'', 2019
The following revisions have been made to the project Plumbing plans to bring them into
alignment with updated Architectural plans. We have dated these revisions as
12/12/2019:
Sheet
Revision Description
P-001
Updated Plumbing Index.
P-002
Added criteria to BOD for lab cold water.
Added criteria to BOD for lab hot water and recirculation.
Added criteria to BOD for corrosive resistant waste and vent piping.
Updated lab vent specifications.
Updated Lab waste specifications.
P-003
Added S-3 to Plumbing Fixture Schedule.
Added Sump Pump Schedule.
Removed L-1 and WC-1 from Plumbing Fixture Schedule
Added Thermal Expansion Tank Schedule.
P-020
Removed WC-1 and L-1 from Sanitary Waste & Vent Diagram.
Added S-1 to Sanitary Waste and Vent Diagram
Added lab waste tie-in to Sanitary Waste and Vent Diagram.
Revised Lab Waste & Vent Diagram to show lab waste routing to Sanitary.
Removed FS-1 from Sanitary Waste & Vent Diagram.
Added future grossing stations to Lab Waste & Vent Diagram.
P-021
Added S-1 to Lab Water System Diagram.
Removed Restroom W214 Water Diagram.
Updated Coffee W216 Diagram to include Mothers W214.
Revised Lab Water System Diagram to include various lab equipment connections.
Updated Tempered Water System diagram to reflect revised pipe routing.
P'111
Revised waste system routing.
Added access panels.
Revised Lab waste routing.
Removed connections toVVC'1&L1,added connections toS'1inVV3l4.
Added General Note D
Removed Key Note 3,6,7and 1Zfrom 1O/14/19Permit Set and reassigned Key
Note numbers inthe 12/12/19update. Key Note 9isnew.
Removed waste connection toFS'1. Nolonger needed.
Revised 2" DCVV Up location toJanitor Closet,
P'112
Added General Note D
P-121
Added5'1 and revised location at8rid|inesC-1.
Removed VV[-1and L'1and added S'3.
Added General Note D.
Removed Key Note 3and 4from 1U/14/19Permit Set and reassigned Key Note
numbers inthe 12/12/l9update. Key Note 3,4and 5are new,
Added water connections for Millipore systems
Added water and waste services for EQPO65,081,D64Q'O82.
Added connections for future grossing stations.
Revised locations for RPBP'2'1,TK4V'3'1 &TMV-J'Z and associated piping to
Janitor Closet VV2O2. Previously these were in theVVZ15 Closet,
Removed FS'1from VV31Scloset. Nolonger needed.
p'122
Added General Note D.
Removed Key Note 2 from 10/14/19 Permit Set and reassigned Key Note numbers
inthe 13/12/19update. Key Note ]isnew.
P'4OO
Added General Note D.
Removed Key Note Zfrom 1O/14/19Permit Set and reassigned Key Note numbers
inthe 1Z/12/19update. Key Note 2'3,4,5,6are new.
' '
Added SP'1-U1for elevator sump to Level 01- Below Grade Plumbing Plan.
Replaced Plumbing Section view Z/P-4ODwith Janitor Closet enlarged plan and
associated elevation views.
Please call [newith any questions that you may have at 206-832-8421.
DmnidMa
Senior Mechanical Engineer
K8cKinoin/Co.
3 Department reupouono.dnc 2
0
Ncr
Labor & Industries (https://lni.wa,00v)
Contractors
MCKINSTRY CO LLC
Owner or tradesperson
Principals
ALLEN, DEAN CHARLES, PARTNER/MEMBER
Hagar, Joseph Donald, PARTNER/MEMBER
PEDERSEN, JAMIE D, AGENT
MOORE, DOUGLAS
JAMES, PARTNER/MEMBER
(End: 03/01/2018)
ALLEN, DAVID
EDWARD, PARTNER/MEMBER
(End: 03/01/2018)
TEPLICKY, JOSEPH
WILLIAM, PARTNER/MEMBER
(End: 03/01/2018)
Doing business as
MCKINSTRY CO LLC
WA UBI No.
602 569 922
PO BOX 24567
SEATTLE, WA 98134
206-762-3311
KING County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active
Meets current requirements.
License specialties
GENERAL
License no.
MCKINCL942DW
Effective — expiration
03/16/2006— 03/16/2020
Bond
WESTERN SURETY CO
Bond account no
929511574
$12,000.00
Received by L&I Effective date
09/02/2010 09/09/2010
Expiration date
Until Canceled
Insurance
Travelers Indemnity Company Th $2,000,000.00
Policy no.
VTC2KC05643B9011ND18
Received by L&I Effective date
11/14/2018 01/31/2018
Expiration date
01/31/2020
Insurance history
No savings accounts during the previous 6 year period.
ylerwAHUUF.rvt
rW\Documents\118108-MP-CELLNETIX-v19
2/13/2019 11:
ABBREVIATIONS
GENERAL
AD
AFF
AFC
BHP
BOP
BOT
C/L
CLG
CFM
CO
CO2
CSR
DFU
DISCH
DN
DS
(E)
EA
EC
EP
EPO
ESP
(F)
FA
FDC
FDN
FLEX
FLR
FP
FTG
FU
GA
GALV
GC
HP
HTG
HTR
IAW
ID
IN WC
MC
MFR
MH
MTD
N/A
NC
NIC
NO
NOM
NTS
OC
OD
OVHD
ACCESS DOOR
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
BRAKE HORSEPOWER
BOTTOM OF PIPE
BOTTOM
CENTER LINE
CEILING
CUBIC FEET PER MINUTE
CARBON MONOXIDE
CARBON DIOXIDE
CURRENT SENSING RELAY
DRAINAGE FIXTURE UNIT
DISCHARGE
DOWN
DISCONNECT SWITCH; DOOR SWITCH
EXISTING
EACH
ELECTRICAL CONTRACTOR; END CAP
ELECTRICAL PANEL; END PLUG
EMERGENCY POWER OFF
EXTERNAL STATIC PRESSURE
FUTURE
FIRE ALARM
FIRE DEPARTMENT CONNECTION
FOUNDATION
FLEXIBLE
FLOOR
FIRE PROTECTION
FOOTING
FIXTURE UNIT
GAGE
GALVANIZED
GENERAL CONTRACTOR
HORSEPOWER; HIGH PRESSURE
HEATING
HEATER
IN ACCORDANCE WITH
INSIDE DIAMETER/DIMENSION
INCHES WATER COLUMN
MECHANICAL CONTRACTOR
MANUFACTURER
MANHOLE
MOUNTED
NOT APPLICABLE
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN, NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
PERF PERFORATED
POC POINT OF CONNECTION
QTY
(R)
RCP
REQD
SECT
SIM
SPEC
STD
TBD
TI
TOC
TOS
TSP
TYP
QUANTITY
RELOCATED
REFLECTED CEILING PLAN
REQUIRED
SECTION
SIMILAR
SPECIFICATION
STANDARD
TO BE DETERMINED
TENANT IMPROVEMENTS
TOP OF CONCRETE
TOP OF STEEL
TOTAL STATIC PRESSURE
TYPICAL
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
VFD VARIABLE FREQUENCY DRIVE
VSD VARIABLE SPEED DRIVE
W/
W/O
WC
WG
WITH
WITHOUT
WATER COLUMN
WATER GAUGE
PLUMBING
AD AREA DRAIN
ADW ANIMAL DRINKING WATER
AR ARGON
BFS BOTTLE FILL STATION
CO
CRV
CRW
DCW
DF
DFBF
DHW
DHW-105°
DHW-140°
DHW-180°
DHWR
DIR
DIS
DR
DS
EWC
EWCBF
FCD
FCO
FD
FE
FI
#2 G
#5 G
GARW
GW
GWW
CLEAN OUT
CORROSION RESISTANT VENT
CORROSION RESISTANT WASTE
DOMESTIC COLD WATER
DRINKING FOUNTAIN
DRINKING FOUNTAIN - BOTTLE FILLER
DOMESTIC HOT WATER
DOMESTIC HOT WATER -105 DEG F
DOMESTIC HOT WATER -140 DEG F
DOMESTIC HOT WATER -180 DEG F
DOMESTIC HOT WATER RECIRCULATION
DE -IONIZED WATER RETURN
DE -IONIZED WATER SUPPLY
WATER FEATURE DISPLAY RETURN
WATER FEATURE DISPLAY SUPPLY
ELECTRIC WATER COOLER
ELECTRIC WATER COOLER - BOTTLE FILLER
FLUE CONDENSATE DRAIN
FLOOR CLEAN OUT
FLOOR DRAIN
WATER FEATURE FILTER EFFLUENT
WATER FEATURE FILTER INFLUENT
NATURAL GAS
NATURAL GAS - LOW PRESSURE, 2 PSI
NATURAL GAS - LOW PRESSURE, 5 PSI
GARAGE WASTE
GREASE WASTE
GREY WATER WASTE
HE HELIUM
IA
IE
IRA
IW
LA
LCW
LHW
LHWR
LV
LW
INSTRUMENT AIR
INVERT ELEVATION
IRRIGATION
INDIRECT WASTE
LABORATORY AIR
LABORATORY COLD WATER
LABORATORY HOT WATER
LABORATORY HOT WATER RETURN
LABORATORY VENT
LABORATORY WASTE
MA MEDICAL AIR
N2
N20
NPCW
NPHW
NPHWR
LABORATORY GASEOUS NITROGEN
MEDICAL NITROUS OXIDE
NON POTABLE COLD WATER
NON POTABLE HOT WATER
NON POTABLE HOT WATER RETURN
02 OXYGEN , MEDICAL OR LABORATORY
ORL OVERFLOW RAINWATER LEADER
PD
PHW
PLBG
PRV
PSD
RPBP
RO
ROR
ROS
RWL
RWL FM
PLANTER DRAIN
DOMESTIC PREHEAT WATER
PLUMBING
PRESSURE REDUCING VALVE
SUBSOIL DRAIN (PERFORATED)
REDUCED PRESSURE BACKFLOW PREVENTER
REVERSE OSMOSIS WATER
REVERSE OSMOSIS WATER RETURN
REVERSE OSMOSIS WATER SUPPLY
RAINWATER LEADER
RAINWATER LEADER FORCE MAIN
RWR RECLAIM WATER RETURN
RWS RECLAIM WATER SUPPLY
SD
SS
SSD
STORM DRAIN
SANITARY SEWER
SUBSOIL DRAIN
TP TRAP PRIMER
TW TEMPERED WATER (EMERGENCY ONLY)
V
VAC
VTR
W FM
WC
WGE
WH
WSFU
SANITARY VENT
MEDICAL VACUUM, LABORATORY VACUUM
VENT THROUGH ROOF
SANITARY WASTE
SANITARY WASTE FORCE MAIN
WATER CLOSET
WASTE GAS EXTRACTION
WATER HEATER
WATER SUPPLY FIXTURE UNIT
GENERAL INFORMATION SYMBOLS
C
0 0
T
v
NEW PLUMBING WORK
FUTURE TI SCOPE & NEW WORK OTHER THAN PLUMBING
POINT OF CONNECTION
POINT OF DEMOLITION
CENTERLINE
KEY NOTE REFERENCE
PLUMBING FIXTURE CALLOUT
(SEE PLUMBING SCHEDULES
PLUMBING RISER CALLOUT (DCW; DHW; WN)
PLUMBING RISER#
PLAN NUMBER
SHEET NUMBER WHERE PLAN SHOWN
DETAIL OR DIAGRAM NUMBER
SHEET NUMBER
WHERE DETAIUDIAGRAM SHOWN
SECTION LETTER
SHEET NUMBER WHERE SECTION SHOWN
REVISION NUMBER - DENOTES NUMBER
AND DATE WHEN REVISION OR ISSUE
OCCURED
REVISION CLOUD - DENOTES AREA OF
CHANGE
DETAIL REFERENCE OUTLINE
WITH NUMBER AND SHEET LOCATION
PIPING IDENTIFICATION
PLUMBING
PIPING FITTINGS
0
0
0
VALVES
Ibl
--T
DCW COLD WATER PIPE (POTABLE)
DHW HOT WATER PIPE (POTABLE)
DHWR HOT WATER CIRCULATING (POTABLE)
V VENT PIPE (SANITARY)
ALL OTHER PIPE TYPES - SEE ABREVIATION LIST
TEE UP
TEE DOWN
TEE DN WI ELBOW
TEE UP W/ ELBOW
90° ELBOW UP
90° ELBOW DN
CAP
UNION
FLANGE
FLEX HOSE CONNECTION
DOUBLE BELLOWS FLEX CONNECTION
SINGLE BELLOWS FLEX CONNECTION
FLOW ARROW
REDUCER
SLOPE SYMBOL
BREAK OR CONTINUATION SYMBOL
DOWN SPOUT NOZZLE
CLEANOUT
MOTORIZED 2-WAY VALVE
MOTORIZED 3-WAY VALVE
PRESSURE REDUCING VALVE
CONTROL VALVE
RELIEF VALVE
BALL VALVE
3-WAY GATE VALVE
BUTTERFLY VALVE
DIAPHRAGM VALVE
CHECK VALVE
NEEDLE VALVE
GLOBE VALVE
GLOBE VALVE ANGLE
GLOBE VALVE 3-WAY
GATE VALVE
PLUG VALVE
BALANCING VALVE
HOSE BIBB
AUTO FLOW VALVE
PIPING ACCESSORIES
,LMV
4AV
4HAV
10
LRPBPI
Y
0
PUMP
MANUAL AIR VENT
AUTOMATIC AIR VENT
HIGH CAPACITY AIR VENT
SHOCK ARRESTOR
FLOW SWITCH
VACUUM BREAKER
PRESSURE GAUGE
TEMPERATURE SENSOR
TEMPERATURE INDICATOR(THERMOMETER)
FLOW METER
Y STRAINER W/ BALL VALVE
PIPE SLEEVE
STEAM TRAP
PETES PLUG
SUCTION DIFFUSER W/ STRAINER
REDUCED PRESSURE
BACKFLOW PREVENTOR
FUNNEL DRAIN
FLOOR DRAIN
ROOF DRAIN
ROOF OVERFLOW DRAIN
FLOOR SINK
VICINITY MAP
LEGAL DESCRIPTION
PARCEL NUMBER: 734560-0580
NAME: INTERNATIONAL GATEWAY EAST
PLUMBING INDEX
ALL DRAWINGS ARE INCLUDED IN EACH ISSUANCE,
X INDICATES DRAWING SHEET REVISION.
1 - PERMIT SET 10/14/19
2 - PRELIM. CD SET 11/12/19
3 - CD SET 12/12/19
SHEET NO
SHEET NAME
P-001
PLUMBING LEGEND & ABBREVIATIONS
X
-
X
P-002
PLUMBING B.O.D & SPECIFICATIONS
X
X
-
P-003
PLUMBING SCHEDULES
X
X
X
P-020
PLUMBING WASTE AND VENT DIAGRAMS
X
X
X
P-021
PLUMBING DOMESTIC WATER DIAGRAMS
X
X
X
P-111
PLUMBING PLAN LEVEL 1 WEST
X
X
X
P-112
PLUMBING PLAN LEVEL 1 EAST
X
-
-
P-121
PLUMBING PLAN LEVEL 2 WEST
X
X
X
P-122
PLUMBING PLAN LEVEL 2 EAST
X
-
P-400
PLUMBING ENLARGED PLANS & SECTION VIEWS
X
X
X
P-500
PLUMBING DETAILS
X
LEGAL: RIVERTON ADD LOTS 17 THRU 26 & THEW 50 FT OF LOT 9 BLOCK 8 OF RIVERTON REPLAT TGW LOTS 9 THRU 24 OF BLOCK 7 TGW VACATED 37TH AVE S ADJOINING BLOCK 7 & 8
UNDER VACATION ORDINANCE NO 1937 RECORDING NO 20001227002657 LESS PORTION OF LOTS 9 & 24 IN BLOCK 7 - BEGIN SW CORNER OF BLOCK 7 TH N 01-46-02 E 400.41 FT TO
POINT OF BEGINNING TH N 90-00-00 E 420.13 FT TO POINT ON WLY LINE OF BLOCK 8 & TERMINUS OF SAID LINE LESS PORTION LOTS 16 THRU 20 BLOCK 7, VACATED 37TH AVE S
ADJOINING BLOCKS 7 & 8 AS VACATED BY ORDINANCE N01937 LY SLY AND/OR WLY OF FOLLOWING DESCRIBED LINE BEGIN SE CORNER LOT 17 BLOCK 8 TH N 01.46-02 E 5 FT TO POINT
ON LINE 5 FT NLY, MEASURED AT R/A, FROM S LINE OF BLOCK 7 & 8 AND POINT OF BEGINNING TH N 88-18-50 W 694.62 FT TO BEGIN OF CURVE CONCAVE TO NE WITH RADIUS OF 20 FT
TH WLY & NLY ALONG ARC SAID CURVE THRU C/A 91-04-52 DISTANCE 31.79 FT TO POINT ON LINE 5 FT ELY. MEASURED AT R/A, FROM W LINE OF BLOCK 7 TH N 01-46-02 E 178,17 FT TO
POINT ON N LINE OF LOT 4 DONALDSON ADD EXTENDED ELY TO TERMINUS OF THIS LINE LESS LOT 17 THRU 24 BLOCK 7 PORTION OF REVISED LOT B OF CITY OF TUKWILA BOUNDARY
LINE ADJUSTMENT NO L2000 027 RECORDING NO 200102211001777
GENERAL NOTES
1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL WORK PRIOR TO
START OF CONSTRUCTION.
2. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS NOT
PREVIOUSLY COORDINATED OR AGREED UPON, I.E. ANCHOR BOLT DEPTHS, ETC.
3. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE
SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY THE GENERAL
CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS.
4. HVAC EQUIPMENT SHALL NOT BE SIZED LARGER THAN THE NEXT LARGEST SIZE BASED ON LOAD
CALCULATION. WSEC C403.2.2.
5. OCCUPIED SPACES ARE MECHANICALLY VENTILATED. SYSTEMS ARE DESIGNED TO PROVIDE
MINIMUM OUTSIDE AIR PER MECHANICAL CODE AND SHALL NOT EXCEED 150% CALCULATED VALUE,
WSEC 403.2.6 & 403.2.11.4.
6. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS:
A. MECHANICAL SYSTEMS, EQUIPMENT AND CONTROL SHALL BE COMMISSIONED PER WSEC
408.2.
B. COMMISSIONING PLAN IS REQUIRED TO BE PREPARED BY CERTIFIED COMMISSIONING
PROFESSIONAL AND SUBMITTED TO THE AHJ PRIOR TO FIRST MECHANICAL INSPECTION, PER
WSEC 408.1.2. INCLUDE NARRATIVE OF ACTIVITIES, RESPONSIBILITIES OF Cx TEAM, SCHEDULE
OF ACTIVITIES AND CONFLICT OF INTEREST PLAN.
a. PROVIDE SUMMARY OF REPORT OR COMPLIANCE CHECKLIST (SEE C408.1.4.2) AND
PROVIDE TO OWNER PRIOR TO FINAL MECHANICAL INSPECTION.
C. BALANCE SYSTEMS TO WITHIN TOLERANCES SPECIFIED. FIRST BALANCE TO MINIMIZE
THROTTLING LOSSES THEN TO MEET DESIGN FLOW, WSEC 408.2.2.
D. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNER PER WSEC
C103.6.
E. PROVIDE MAINTENANCE MANUALS FOR ALL MECHANICAL EQUIPMENT, WSEC C103.6.
F. PROVIDE OWNERS OPERATING PERSONNEL TRAINING FOR MECHANICAL EQUIPMENT, WSEC
C103.6.
G. PROVIDE WSEC COMPLIANCE FORMS AND CALCULATIONS, WSEC C103.6.
7. MINIMUM VENTILATION QUANTITIES WILL COMPLY WITH OR EXCEED THE 2015 INTERNATIONAL
MECHANICAL CODE.
8. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN WSEC C403.2.8.1.
9. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO CONNECTION OF
EQUIPMENT FURNISHED BY THE OWNER OR OTHERS.
10. FOR ADDITIONAL SYSTEM AND EQUIPMENT SEISMIC REQUIREMENTS, REFER TO STRUCTURAL
SEISMIC TIE -DOWN INFORMATION AND BACK-UP CALCULATIONS ARE PROVIDED SEPARATELY.
11. REFER TO CIVIL DRAWINGS FOR UTILITY WORK 0-0" BEYOND THE BUILDING LINE.
12. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS SPECIFICALLY MARKED
AS EXISTING, EXIST, OR (E).
PG1 9-0156
PEV!SI
SEPARATE PERMIT
R UIRED FOR:
Mechanical
Electrical
❑ Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
RECEIVED'
((L262014
LI1:WII A
WORKS
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
S A B Architects
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www,sabarch.com
CELLNETIX
FACILITY
RELOCATION
,,C)e, l 7, • (
CONSTRUCTION
DRAWING SET
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 17 2020
City of Tukwila
BUILDING DIVISION
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
LEGEND &
ABBREVIATIONS
DATE
CHECKED BY
PROJECT NUMBER
12/12/2019
DM
118108
firOlup P-0O1
i�u
PLUMBING BASIS OF DESIGN
ITEM # SYSTEM CRITERIA r CRITERIA SOURCE
CODE BASIS FOR PROJECT
1-1
CODE
2015 UNIFORM PLUMBING CODE ENFORCED BY LOCAL JURISDICTION
TUKWILA
1-2
CODE
2015 WASHINGTON STATE ENERGY CODE
TUKWILA
1
BASIS FOR EXISTING DOMESTIC WATER SYSTEM
2-1
TEMPERATURE
ENTERING WATER TEMPERATURE = 50°F
EXISTING
2-2
WATER PRESSURE
70 PSI
EXISTING
BASIS FOR SCOPE OF WORK
3-1
PLUMBING FIXTURES
- PROVIDE AND INSTALL (1) UWATORY.
- PROVIDE AND INSTALL (1) WATER CLOSET.
- PROVIDE AND INSTALL (3) NEW KITCHEN SINK.
DESIGN APPROACH
3-2
LAB FIXTURES
- INSTALL (15) EXISTING LAB SINKS.
PROVIDE AND INSTALL (4) NEW EMERGENCY EYE WASH/SHOWER STATIONS.
DESIGN APPROACH
3-3
DOMESTIC WATER
INSTALL DOMESTIC COLD AND HOT WATER AS INDICATED ON PLANS. PIPE SHALL NOT
EXCEED 8 FPS VELOCITY FOR COLD WATER PIPING AND 5 FPS VELOCTIY FOR HOT WATER
PIPING.
DESIGN APPROACH
3-4
PRESSURE REDUCING
BACKFLOW
,
PREVENTERS
PROVIDE AND INSTALL BACKFLOW PREVENTERS FOR LAB COLD WATER LINES & HVAC MAKE
UP WATER SYTEM.
DESIGN APPROACH
3-5
EQUIPMENT
PROVIDE AND INSTALL (1) 90kW, 120 GAL STORAGE WATER HEATER TO SERVE THE LAB HOT
WATER SYSTEM.
PROVIDE AND INSTALL (1) 15kW, 120 GAL STORAGE WATER HEATER TO SERVE THE
TEMPERED WATER SYSTEM.
PROVIDE AND INSTALL (1) 5.5 kW INSTANTANEOUS WATER HEATER TO SERVE A NEW SINK
LOCATED IN ROOM W102.
DESIGN APPROACH
3-6
LAB COLD WATER
L E R
STATIONS.
ALL GROSS NG STATIONS TO BE PROVIDED WITH NECESSARY FLEXIBLE LAB COLD WATER
CONNECTIO S.
DESIGN APPROACH
3-7
LAB HOT WATER &
RECIRCUIATION.2
IN ' LL A NEW I"' : WATERL TO SERV L LABORA RY SINKS GROSSI
STATIONS.
INSTALL A NEW THERMOSTATIC MIXING VALVE OFF OF LAB COLD AND HOT WATER SYSTEM
TO ENSURE WATER TEMPERATURE DELIVERED BELOW 120F.
LL A IRC N AC 0 VE E IT F
ST LABO TORY FIXTU E.
ALL GROSSING STATIONS TO BE PROVIDED WITH NECESSARY FLEXIBLE LAB HOT WATER
CONNECTIONS.
DESIGN APPROACH
33
TEMPDWATER
SYSTEM
P IDEANDI ALL THER TATIC MI VALVE 0 OF DOMES COLD AN
WAT ERSYSTEMT°PR°VDETEMPERE DWATERT O ALLEMERGENCYEYEAASH/SHOWER
FIXTURESTEMPEREDWATERSYSTEMDEs,GNEDWTHD,vER,TyoF2FuREs
SIMULTANEOUSLY USED.
DESIGN APPROACH
3-9
LAB GASES
NO SPECIALTY GASES IN SCOPE OF WORK.
DESIGN APPROACH
3-10
WASTE AND VENT
INSTALL NEW WASTE SYSTEM IN CEILING BELOW AND CONNECT TO EXISTING BUILDING
WASTE PIPE.
INSTALL NEW VENT SYSTEM IN CEILING OF SECOND FLOOR AND DISCHARGE THROUGH THE
ROOF.
DESIGN APPROACH
3-11
CORROSIVE
RESISTANT WAST
AND VENT
INSTALL NEW CORROSIVE RESISTANT WASTE SYSTEM FOR THE GROSSING STATIONS IN
CEILIN BELOWA ROUTE TO ELOW SLA ANITARY STE PIPIN
ALL RO ISTA SY R T SIN NS CEI ING
OF SECON FLOOR AN DISCHARG THROUGH E ROOF. 2
ALL GROSSING STATIONS TO BE PROVIDED WITH NECESSARY FLEXIBLE WASTE
CONNECTIONS.
LOCALIZED GROSSING STATION CHEMICAL WASTE CONTAINMENT SYSTEMS BYSWNER.
DESIGN APPROACH
LNETIX-v19_tylerwAHUUF.rvt
3/2019 11:55144164rs\TylerVV\Documents\118108-MP-CE
PLUMBING SPECIFICATION
PRESSURE TEST PROCEDURE
SEISMIC
INSULATION
ID
CATEGORY
SERVICE DESCRIPTION
MANUFACTURER, PRODUCT OR EQUAL
MED"i"1 TEST
PRESSURE
DURATION
CODE
IMPORTANCE
IP
&
JACKETING
DCW, DHW
DHWR, TW
(POTABLE)
DOMESTIC COLD WATER
DOMESTIC HOT WATER to 160 DEG F
DOMESTIC HOT WATER RECIRCULATION TO 160 DEG F.
TEMPERED WATER
DOMESTIC HOT AND COLD WATER SERVICE
COMPLY WITH NSF-61 AND NSF 372
100% OF OPERATING
PRESSURE
15 MINUTES
OR
MFG SPEC
UPC
CHAPTER 6
NSF 61
UPC APPENDIX A
IAPM0
INSTALLATION
STANDARDS
1.0
PER W.S.E.0
SEE INSULATION
SCHEDULE
NO INSERTS AT
HANGERS
USE INSERTS AT
CLAMPS
INSERTS TO BE
STYRENE
PIPE IDENTIFICATION MARKERW'lLHITE
LETTERING ON GREEN BACKGROUND
OPERATING PRESSURE
UP TO 100 PSI; SET RELIEF TO XXX PSI
WATER
or
AIR (NOT FOR
PLASTIC PIPE)
SIZES THRU 2''
PIPE MATERIAL
COPPER TUBE TYPE L ASTM B88
PER SUBMITTAL
JOINTS
L,FIT MECHANICALCOMPRESSION - THREADED AT SPECIA T ES
JOINTS
SWEAT: WATER BASED FLUX ASTM 8813; LEAD FREE SOLDER ASTM B-32
JOINTS
SILVER BRAZED : PER UPC CHAPTER 6
COUPLINGS
COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22
VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM)
FITTINGS
COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16,22
VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM)
FITTINGS
CAST BRONZE -SWEAT- ASTM B584 - LEAD FREE - NSF 61
VALVES - ISOLATION
PRESS FIT LEAD FREE BRONZE BALL VALVE -FULL PORT-1/4 TURN - NSF 61G & 372
MILWAUKEE UPBA-480B; VIEGA PROPRESS-2971 or 2970;APOLLO 77VLF-100
MILWAUKEE UPBA-4858, APOLLO 77CLF-200
VALVES - ISOLATION (ALT)
_
SWEAT - LEAD FREE 2-PC BRONZE BALL VALVE -FULL PORT - 1/4 TURN - NSF 61G & 372
SIZES 2-1/2" AND UP
PIPE MATERIAL
STAINLESS STEEL PIPE TYPE 304L SCH 10S A3 2 SEAMLESS
PER SUBMITTAL
JOINTS
BUTT WELD - GROOVED (ALTERNATE)
COUPLINGS
GROOVED GALVANIZED DUCTILE IRON RIGID -COUPLING - NSF 61 & NSF 372
VICTAULIC - STYLE 89 - EPDM GASKET
FITTINGS
SCH 10S TYPE 304 SS - ASTM A403
VICTAULIC - PER SUBMITTAL
VALVES - ISOLATION
DUCTILE IRON- LINED - BUTTERFLY VALVE - LUGGED - MSS-SP 67 & N F- 72
MILWAUKEE CL223E; APOLLO LD-141 - EPDM LINER
VALVES- ISOLATION (ALT)
GROOVED STAINLESS STEEL - BUTTERFLY - EPDM SEAL - NSF 61 & NSF 372
V CTAULIC SERIES 461 - EPDM GASKET/O-RING
LCW, LHW, LHWR
(NON -POTABLE)
LAB COLD WATER
LAB HOT WATER TO 160 DEG F
LAB HOT WATER RECIRCULATION TO 160 DEG F
HOT & COLD WATER SERVICE FOR INDUSTRIAL OR LABORATORY PROCESS
WATER
or
AIR (NOT FOR
PLASTIC PIPE -
EXCEPT FOR
PEX)
100% OF OPERATING
PRESSURE
15 MINUTES
OR
MFG SPEC
UPC
CHAPTER 6
1.0
PER W.S.E.0
SEE INSULATION
SCHEDULE
NO INSERTS AT
HANGERS
USE INSERTS AT
CLAMPS
INSERTS TO BE
STYRENE
PIPE ISENTIFICATISN MARKER
CAUTION: NON POTABLE WATER, DO NOT DRINK - BLRCK LETTERS ON YELLOW BACKGROUND
OPERATINGSPERATINSPRESSSRE
UP TO 100 PSI; SET RELIEF TO XXX PSI
SIZES THRU 2"
PIPE MATERIAL
COPPER TUBE TYPE L ASTM B88
PER SUBMITTAL
JOINTS
PRESS -FIT MECHANICAL COMPRESSION - THREADED AT SPECIALTIES
JOINTS
SWEAT: FLUX ASTM B8 3; LEAD FREE SOLDER AST B- 21
COUPLINGS
COPPER - PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22
VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS EPDM)
FITTINGS
COPPER- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22
VIEGA PROPRESS; EPDM SEAL (BLACK), APOLLO PRESS (EPDM)
FITTINGS
CAST BRONZE -S T- ASTM 8584
VALUES- ISOLATION
PRESS FIT BRONZE BALL VALVE-FU PORT-1/4 TURN
MBWAUKEE BA-480B; VIEGA PROPRESS-2973; APOLLO 77V-100
MILWAUKEE BA-485B; APOLLO 77C-200
VALVES- ISOLATION
SWEAT- 2-PC BRONZE BALL VALVE -FUL PORT - /4 TURN
SIZES 2-1/2" AND UP
PIPE MATERIAL
STAIN ESS STEE PIPE TYPE 304L SCH 10S A312 SEAMLESS
PER SUBMITTAL
JOINTS
GROOVED
COUPLINGS
GROOVED GALVANIZED DUCTILE IRON RIGID -COUPLING
VICTAULIC - STYLE 89 - EPDM GASKET
FITTINGS
GROOVED SCH 10S TYPE 304 SS - ASTM A403
VICTAULIC - PER SUBMITTAL
VALVES - ISOLATION
DUCTILE IRON - LINED - BUTTERFLY VALVE - LUGGED - MSS-SP 67
MILWAUKEE CL223E; APOLLO LD-141 - EPDM LINER
VALVES - ISOLATION (ALT)
GROOVED STAINLESS STEEL - BUTTERFLY - EPDM SEAL
VICTAULIC SERIES 763 - EPDM GASKET/O-RING
VALVES- ISOLATION (ALT)
GROOVED DUCTILE IRON -NYLON COATED- BUTTERFLY- EPDM SEAL
VICTAULIC 300 SERIES 761 - EPDM GASKET; ANVIL AN-7721-3;
TP
(NON -POTABLE)
TRAP PRIMER - ABOVE GROUND
TRAP PRIMER
WATER
WATER
10 FT HEAD
FILL SYSTEM FROM
LOWEST TO HIGHEST
POINT OF TEST
SECTION
DO NOT USE AIR FOR
PLASTIC PIPE
TESTING
15 MINUTES
UPC
CHAPTER 7
10
NIA
OPERATING PRESSURE
DESIGN HEAD PRESSURE TO ACCOMMODATE LIFT REQUIRED
SIZES UP TO 1/2"
PIPE MATERIAL
COPPER TUBE TYPE L SOFT ANEALED (PREFERRED) ASTMB88
OR
COPPER TUBE TYPE L HARD DRAWN ASTM B88
PER SUBMITTAL
JOINTS
SWEAT; WATER BASED FLUX ASTM B813; LEAD FREE SSLDERASTMB-321
PER SUBMITTAL
FITTINGS
WROT COPPER - SWEAT - ASTM BTS
PER SUBM TTAL
FITTINGS
C T RONZE -SWEAT- ASTM 8584
V
SANITARY VENT - ABOVE GROUND
SANITARY VENT - CAST IRON
WATER
WATER
10 FT HEAD
SYSTEM FROM
LOWEST TO HIGHEST
POINT OF TEST
SECTION
DO NOT USE AIR FOR
PLASTIC PIPE
TESTING
VISUAL INSPECTION
WITH NO LEAKS
UPC
CHAPTER 9
1.0
NIA
PIPE IDENTIFICATION MARKER
WHITE LETTERING ON GREEN BACKGROUND
OPERATING PRESSURE
UP TO 5 PSI
1FILL
ALL SIZES (1)
PIPE MATERIAL
CAST IRON NO -HUB ASTM A 8 8 C SPI 301
PER SUBMITTAL
JOINTS
NHCI COUPLINGS- STANDARD - CISPI 310 & ASTM C 1277
PER SUBMITTAL
FITTINGS
CAST IRON DRAIN PATTERNS CISPI 301
PER SUBMITTAL
LV , CRV
LAB VENT, CORROSION RESISTANT VENT - ABOVE GROUND
LAB - CORROSION RESISTANT VENT
WATER
WATER
10 FT HEAD
FILL SYSTEM FROM
LOWEST TO HIGHEST
POINT OF TEST
SECTION
DO NOT USE AIR FOR
PLASTIC PIPE
VISUAL INSPECTION
WITH NO LEAKS
UPC
CHAPTER 9
1.0
.)
I
NIA
I
P PE IDENTIFICATION MARKER
PER NFPA 99 & UPC - SEE SPECIFICATION
OPERATING PRESSURE
UP TO 5 PSI
ALL SIZES ( )
ENGINEER TO DETERMINE CHEMICALS INTHEWASTE
PIPE MATERIAL
CPVC SCH DVVV FSRCHEMICAL WASTESYSTEMSASTM 72618
PER SUBMITTAL - FUSEAL
JOINTS
SOLVENT WELD ASTM 7493
PERSUBMITTAL
FITTINGS
CPVC SOCKET FITTINGS ASTM F26 8 MADE TO ASTM 03311
PERSUBMITTAL-FUSEALTESTING
WATER
1 oVVFATTHEEAR
FILL SYSTEM FROM
LOWEST TO HIGHEST
POINT OF TEST
SECTION
DO NOT USE AIR FOR
PLASTIC PIPE
TESTING
VISUAL INSPECTION
WITH NO LEAKS
UPC
CHAPTER 7
1.0
NIA
PIPE IDENTIFICATION MARKER
WHITE LETTERING ON GREEN BACKGROUND
OPERATING PRESSURE
UP TO 5 PS
A L SIZES (1
PIPE MATERIAL
CAST IRON NO -HUB ASTM A 888 AND CISPI 301
PERSUBMITTAL
JOINTS
NHCI COUPLINGS- STANDARD-CISPI 310 & ASTM C 1277
PER SUBMITTAL
TGs
CAST IRON DRAIN PATTERNS CISPI 30
PER SUBMITTAL
LW , C W
ACID WASTE, CORROSION RESISTANT WASTE -ABOVE GROUND
LABORATORY ACID WASTE, LABORATORY CORROS ON RESISTANT WASTE
WATER 1
;
WATER
10 FT HEAD
FILL SYSTEM FROM
LOWEST TO HIGHEST
POINT OF TEST
SECTION
DO NOT USE AIR FOR
PLASTIC PIPE
TESTING
VISUAL INSPECTION
WITH NO LEAKS
UPC
CHAPTER 7
1.0
N/A
PIPE IDENTIFICATION MARKER
PER NFPA 99 & UPC - SEE SPECIFICATION
OPERATING PRESSURE
UP TO 5 PSI
ALL SIZES (1)
ENGINEER TO DETERMINE CHEMICALS IN THE WASTE
PIPE MATERIAL
CPVC SCH DVVV FOR CHEMICAL WASTE SYSTEMS ASTM 72618 ,
PER SUBMITTAL - FUSEAL
JOINTS
SOLVENTWELDASTM F 93
PER SUBMITTAL
FITTINGS
CPVC SOCKET FITTINGS ASTM F2S18MADETOASTM D3311
PER SUBMITTAL - FUSEAL
11 111 I I MO I I I I IMO
ALL''
I r MI I 11.1 II Mil ffii i .
ALL DOMESTIC WATER SYSTEM COMPONENTS SHALL MEET NSF STANDARD 6111111ROMERFAMPIPAIIILIM
A L PLASTIC DRAINASE SYSTEM COMPONENTSSHALLMEETNSF STANDARD 14
.....AlliM
CODE
ALL
CODE
ALL CAST IRON DRAINAGE SYSTEM COMPONENTS SHALL BE TRADEMARKED WITH CAST IRON SOIL PIPE INSTITUTE
AND BE LISTED BY NSF.
ALL
SPECIALTIES
PLUMBING SPECIALTIES -APPLICABLE SPECIALTIES IDENTIFIED IN EACH ID CATEGORY
THERMOMETER
9" SCALE SIZE, ALUMINUM STEM, FAHRENHEIT SCALE
TRERICE BX9
THERMOWELL
FOR TRERICE BX9 THERMOMETER
TRERICE THERMOWELL
PRESSURE GAUGE
UTILITY PRESSURE GAUGE
TRERICE D80
PRESSURE GAUGE ACCESSORIES
IMPULSE DAMPENER
TRERICE 870
PRESSURE GAUGE ACCESSORIES
PRESSURE SNUBBER
TRERICE 872
PRESSURE GAUGE ACCESSORIES
BALL VALVES
TRERICE 866
PRESSURE GAUGE ACCESSORIES
GAUGE COCKS
TRERICE 865
PRESSURE GAUGE ACCESSORIES
POINTER JACK
TRERICE D329
PRESSURE GAUGE ACCESSORIES
TEST KITS
TRERICE 375X OR 3748
PETE'S PLUG
BRASS WITH NEOPRENE VALVE CORES
PETERSON EQUIPMENT CO PETE'S PLUG 11
PRESSURE REDUCING VALVE SIZES THRU 2"
BALANCED PISTON WITH BY-PASS CHECK VALVE AND STRAINER
WILKINSSOOXL APOLLO 36ELF
PRESSURE RELIEF VALVE
BRONZE BODY
BRONZE BODY
WILKINS P3000BR; WATTS 174A, APOLLO SERIES 10
WILKINS SXL, APOLLO YBS 59 SERIES
VVYE STRAINER SIZES THRU 3"
BACKFLOW PREVENTER SIZES THRU 2"
REDUCED PRESSURE BACKFLOW
WILKINS 975XL2, APOLLO RP 4ALF
TRAP PRIMER
1-1/2" SWEAT COPPER WALL CONNECTION
ZURN Z1021
TRAP PRIMER
ELECTRONIC MODULE AND FIVE CONNECTION MANIFOLD
ZURN Z1020
TRAP PRIMER
1/2" CONNECTION PRESURE DROPACTIVATED
MIFAB M-500
THERMOSTATIC MIXING VALVE
1-1/2" INLET CONNECTIONS
LAWLER 804, APOLLO 34C
EMERGENCY FIXTURE THERMOSTATIC MIXING VALVE
EMERGENCY SHOWER
LAWLER 911, APOLLO 34E T/S
BALANCING VALVE
IN -LINE VALVE - FACTORY SET - NSF-6 NSF-372
TA SERIES 76X
NOTES: 1, MCKINSTRY DOES NOT INSTALL 5" DM.
2. SEE PIPING MATRIX FOR NATURAL GAS
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
5 A B ArchteLts
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
REVIEWEE, FOR
CODE COMPLIANCE
APPROVED
iAN 7 202u
City of Tukwila
BUILDING DIVISION
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
B.O.D &
SPECIFICATIONS
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
P-002
PG19 0 56
THERMOSTATIC MIXING VALVE SCHEDULE
GENERAL NOTES:
1. SEE MATERIALS MATRIX FOR PIPING MATERIALS OF CONSTRUCTION FOR CONNECTION TYPE
2. VALVES SHALL BE LEAD FREE - NSF/ANSI 61 LISTED
3. HANDWASH SINKS REQUIRE A MINIMUM OF 100 DEG F (FDA FOOD CODE 2009 5-202.12 & WASHINGTON ADMINISTRATIVE CODE (WAC) 246-215-05210)
4. HANDWASH SINKS SHALL HAVE SELF CLOSING / METERING OF FAUCET FORA MINIMUM OF 15 SECONDS
5. HANDWASH PUBLIC LAVATORIES SHALL BE LIMITED TO 120 DEF F BY A DEVICE THAT IS ASSE 1070 OR GSA B125.3 (UPC 421.2)
6. ASSE 1017 MASTER SUPPLY MIXING VALVES AT THE HOT WATER SOURCE SHALL BE VALIDATED TO BE ACCEPTABLE IF USED IN RECIRCULATION SYSTEMS.
7. ASSE 1017 MASTER SUPPLY MIXING VALVES AT THE HOT WATER SOURCE CAN NOT BE USED BY ITSELF TO CONTROL FINAL TEMPERATURE AT FIXTURES REQUIRED
TO HAVE AN ASSE 1070 OR ASSE 1016 DEVICE
8. CONFORM WITH ENERGY CODE REQUIREMENTS FOR MAXIMUM DISTANCE FROM HOT WATER SOURCE TO FIXTURE
SPECIFIC NOTES:
1. ASSE 1017 DEVICE FOR VALVE USED IN HOT WATER SOURCE APPLICATION
2. ASSE 1069 DEVICE FOR SINGLE PIPE, TEMPERED WATER APPLICATION
3. ASSE 1070 DEVICE FOR INDIVIDUAL (POINT -OF -USE) OR MULTIPLE FIXTURE APPLICATION
4. ASSE 1071 DEVICE FOR PLUMBED EMERGENCY EQUIPMENT TO PROVIDE TEPID WATER AND HAVE REDUNDANT SAFETY FEATURES
5. ADJUST CAP WITH LOCKING FEATURE
6. INTEGRAL FILTER AND CHECK VALVES
7. COLD OUTLET CONNECTION FOR DUAL FACUCET LAV/SINK
8. HIGH -LOW OVER A WIDE RANGE OF FLOWS - WITH SCALD PROTECTION FROM FAILURE OF T-STAT & WATER SHUT-OFF, ASSE-1017 / CSAB125.3 APPROVED
9. INTERGRAL THERMOSTAT
DESCRIPTION
PERFORMANCE
EQUIPMENT
CLASSIFICATION
EQUIPMENT ID ! LOCATION
AREA/SYSTEM
SERVED
STATUS
MANUFACTURER
MODEL
ASSOCIATED
CIRC PUMP
EWT
LWT
DESIGN
FLOWRATE
(GPM)
DESIGN MIN
FLOWRATE
(GPM)
DESIGN MAX
FLOWRATE
(GPM)
DESIGN WATER
PRESSURE DROP
(PSI)
CW INLET
CONNECTION
(IN)
HW INLET
CONNECTION
(IN)
OUTLET SPECIFIC NOTES
CONNECTION
(IN)
TMV
2-1
TMV
2-2
12/13/2019 11:55iD9rs\TyterW\Dacumeets\118108-MP-CE
• . . r r r r r r Y Y Y
PLUMBING FIXTURE SCHEDULE
TAG
AG-1
IMIIIIMIIIIIMIICBEMII
DW
MODEL
-
CONNECTION
NOTES
-
AIR GAP FITTING
CW
HW
TEMP j W V RWL ORL
ZURN Z1024 FIXED AIR GAP FITTING
- SPP - WITH APPROPRIATE OPTIONS AND ACCESSORIES FOR THE SPECIFIC USE
DISHWASHER
FIXTURE:
AIR GAP:
SUPPLIES:
PROVIDED BY OTHERS
KOHLER K-9110 AIR GAP, SOLID POLYPROPYLENE BODY, BRASS CAP.
20" CHROME SUPPLIES W/ 3/8" COMP. FITTINGS, ANGLE STOPS AND ESCUTCHEON PLT, KEYLESS (COMMERCIAL)
1/2
ESEW-1
EMERGENCY SHOWER & EYEWASH
FC0.1
FIXTURE:
CLEANOUT, FLOOR
GUARDIAN MODEL G1950 SAFETY STATION WITH SHOWER, EYE/FACE WASH, STAINLESS STEEL BOWL AND 10" DIAMETER SHOWER HEAD, FC20 REGULATES
FLOW TO 20 GPM
1
FIXTURE: I ZURN ZN1400, ADJUSTABLE TOP, HEAVY DUTY, NICKLE BRONZE FINISH
I I SPP I r WITH APPROPRIATE OPTIONS AND ACCESSORIES FOR THE SPECIFIC USE
FS-1
FLOOR SINK - LOW FLOW
FIXTURE: I ZURN Z1960, 8" DIAMETER, 6" SUMP DEPTH
SPP -
WITH APPROPRIATE OPTIONS AND ACCESSORIES FOR THE SPECIFIC USE
S-1
SINGLE COMPARTMENT LAB SINK
FIXTURE:
FAUCET:
DRAIN:
TRAP:
SUPPLIES:
I JUST USXDF-1824-16, 16 GA STAINLESS STEEL, SINGLE BOWL, SELF RIMMING, OD 18 X 24, ID 16 X 22 X 12, 1 HOLE
CHICAGO FAUCETS 930-GN8BVBE7-317XK DECK, SINGLE HOLE, HOT AND COLD MIXING FAUCET WITH VACUUM BREAKER
JUST J-35 CRUMB CUP WITH 1-1/2" TAILPIECE
I ORION BOTTLE TRAP, BT-2
120" CHROME SUPPLIES W/ 1/2" NOM. X 3/8" COMP. ANGLE STOP AND ESCUTCHEON, LOOSE KEY
1/2
1/2
2 ! 1-1/2
- -
I
OR APPROVED ALTERNATE
S-2
SINGLE COMPARTMENT KITCHEN SINK (ADA)
FIXTURE:
FAUCET:
DRAIN:
TRAP:
OOD ISPO
P LIES:
JUST SL-ADA-2225-A-GR, 18 GA STAINLESS STEEL, SINGLE BOWL, SELF RIMMING, DRAIN CENTER REAR, OD 22 X 25, ID 16 X 22 X 5, 3 HOLE
KOHLER - K - 647, LOW FLOW AERATOR (1 GPM), CERAMIC DISC VALUE POLISHED CHROME
JUST J-35 CRUMB CUP WITH 1-1(2" TAILPIECE
ZURN Z8702-PC-BX, 1-1/2" X 1-1/2", 17 GAUGE CHROME PLATED BRASS
SE BAD CONTI FEED 1 115V/1/ MPS
2 CH OME S LI S W/ 1/2 0 . X 3/8" MP. ANGLE 0 AND ES TC EON L S KEY
1/2
1/2
- ' 2 1-1/2
I
-(
"- OR APPROVED ALTERNATE
S 3
SINGLE COMPARTMENT KITCHEN SINK (ADA)
FIXTURE:
FAUCET:
DRAIN:
TRAP:
FOOD WASTE DISPOSER:
SUPPLIES: j
T JUS SLN 17519-A-GR 18 GA STAINLESS LESS STEEL SINGLE BOWL SELF RIMM
ING, MING, DRAIN CENTER REAR, OD 17112 X 18, ID 16 X 11 112 X 71/2, 3 HOLE
KOHLER - K - 647, LOW FLOW AERATOR (1 GPM), CERAMIC DISC VALUE POLISHED CHROME
JUST J-35 CRUMB CUP WITH 1-1/2" TAILPIECE
ZURN Z8702-PC-BX, 1-1/2" X 1-1/2", 17 GAUGE CHROME PLATED BRASS
ISE BADGER 1, CONTINIOUS FEED, 1/3 HP, 115V/1/60, 6.1 AMPS
20" CHROME SUPPLIES W/ 1/2" NOM. X 3/8" COMP. ANGLE STOP AND ESCUTCHEON, LOOSE KEY
1/2
1/2
- 2 1 1-1/2
OR APPROVED ALTERNATE
WCO 1
CL-ANOUT, WAL
CTU Z14 L CLE UN COV SHE .SS 7C ISH
HAP TE 0 ND RIES SPE
WCO-2
CLEANOUT, WALL
FIXTURE: ZURN Z1446 WALL CLEANOUT, ROUND ACCESS COVER, POLISHED STAINLESS STEEL FINISH
- r - j SPP I WITH APPROPRIATE OPTIONS AND ACCESSORIES FOR THE SPECIFIC USE
NOTE:
THE ABOVE DATA SHALL BE USED FOR PRELIMINARY ELECTRICAL, STRUCTURAL OR ARCHITECTURAL COORDINATION ONLY.
USE APPROVED MANUFACTURERS SUBMITTAL DATA FOR CONSTRUCTION.
SPP = SIZE PER PLANS.
8 A A A A A A i r•
WATER HEATER SCHEDULE - ELECTRIC
GENERAL NOTES:
1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
2. MAINTAIN CLEARANCES PER MANUFACTURER'S RECOMMENDATIONS & NEC.
SPECIFIC NOTES:
1. ASME TANK
DESCRIPTION
PHYSICAL DIMENSIONS
PERFORMANCE
ELECTRICAL
SPECIFIC NOTES
EQUIPMENT
CLASSIFICATIONEQUIPMENT
ID
LOCATION
I AR./ SYSTEM
SERVED
STATUS
MANUFACTURER
MODEL
TYPE
DIAMETER OR
LENGTH (IN)
WIDTH
HEIGHT
(IN)
OPERATING
WEIGHT
(LBS)
STORAGE
CAPACITY
(GAL)
ENTERING
WATER TEMP
(°F)
STORAGE
WATER TEMP
(°F)
LEAVING WATER
TEMP
(°F)
RECOVERY
CAPACITIES
(GPH)
HOT WATER
CONNECTION SIZE
(IN)
CAPACITY (kW)
VOLTAGE
()
PHASE
(0)
FULL LOAD
AMPS
(A(
EWH
1-1
LIBRARY W102
KITCHENETTE
SINK
NEW
CHRONOMITE
SR-201/277
ELECTRIC
10"
3„
7"
5
0
55
110
N/A
1/2"
5 5
277
1
20.0
EWH
2-1
LEVELCLOSETJANITOR
LAB WATER
NEW
LOCHINVAR
CHX-90-120-A
ELECTRIC
37"
701/4"
1454
120
55
140
140
410
1 1/4"
940
480
3
108.3
EWH
2-2
LEVEL
CLOSET JANITOR
OSETTOR
ESEW
NEW
LOCHINVAR
CHX-15-120-A
ELECTRIC
37"
701/4"
1454
120
55
120
120
88
1 1/4"
150
480
3
18.0
1
P - THERMAL EXPANSION TANK SCHEDULE
GENERAL NOTES:
1. SEE MATERIALS MATRIX FOR MATERIALS OF CONSTRUCTION.
2. PRECHARGE TO MINIMUM OPERATING PRESSURE AT TANK LOCATION
SPECIFIC NOTES:
1. ASME RATING REQUIRED
2. MANUFACTURER'S CERTIFICATE OF COMPLIANCE INCLUDED PER IBC 1708.4
DESCRIPTION
-
PERFORMANCE
SPECIFIC NOTES
EQUIPMENT
CLASSIFICATION
EQUIPMENT ID
LOCATION
AREA I SYSTEM
SERVED
STATUS
MANUFACTURER
MODEL
DIAMETER
(IN)
�
HEIGHT
(IN)
INLET SIZE
(IN)
INLET CONNECTION
TYPE
OPERATING WEIGHT
(LBS)
FLUID TYPE
SYSTEM VOLUME
(GAL)
TANK VOLUME
CAPACITY
(GAL)
TANK ACCEPTANCE
VOLUME CAPACITY
(GAL)
SYSTEM
TEMPERATURE RANGE
(°F)
SYSTEM PRESSURE
RANGE AT TANK
CONNECTION
RELIEF VALVE SETTING
(PSIG)
PET
2-1
LEVEL 2 JANITOR
CLOSET
LAB WATER
NEW
BELL & GOSSETT
PT-30V
15 3/8
24 3/4
1
NPTF
118
WATER
120
14
11.3
140
(PSIG)
75
100
PET
2-2
LEVEL 2 JANITOR CLOSET
ESEW
NEW
BELL & GOSSETT
PT-30V
15 3/8
24 3/4
1 NPTF
118
WATER
120
14
11.3
120
75
100
P - DOMESTIC HOT WATER CIRCULATION PUMP SCHEDULE
GENERAL NOTES:
SEE MATERIALS MATRIX FOR MATERIALS OF CONSTRUCTION.
SPECIFIC NOTES:
1 INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
DESCRIPTION
PERFORMANCE
ELECTRICAL
SPECIFIC NOTES
EQUIPMENT
CLASSIFICATION
EQUIPMENT ID
LOCATION
AREA /SYSTEM SERVED
STATUS
MANUFACTURER
MODEL
TYPE
DESIGN PUMP FLOW PUMP HEAD
(GPM) , (PSIG)
FLUID TEMPERATURE
("F)
QUANTITY OF ELECTRICAL
CONNECTIONS
(#)
VOLTAGE
(V)
PHASE
(0)
MOTOR HP
(HP)
FULL LOAD AMPS
(A)
MOTOR SPEED
(RPM)
LHWRP
2-1
LEVEL 2 JANITOR CLOSET
LAB WATER
NEW
BELL F. GOSSETT
ECOCIRC XLN 20-35
ECM
10 j 15
120
1
115
1
1/12
t.3
N/A
P - BACKFLOW PREVENTION SCHEDULE
GENERAL NOTES:
1 SEE MATERIALS MATRIX FOR MATERIALS OF CONSTRUCTION OF PIPING SYSTEMS SERVICED
2 DCVA: DOUBLE CHECK VALVE ASSEMBLY (LOW HAZARD)
3 DCDA: DOUBLE CHECK DETECTOR ASSEMBLY (FIRE - LOW HAZARD)
4 RPBA: REDUCED PRESSURE BACKFLOW ASSEMBLY (HIGH HAZARD)
5 RPDA: REDUCED PRESSURE DETECTOR ASSEMBLY (FIRE - HIGH HAZARD)
6 DEVICES SHALL BE TESTED AND APPROVED AS LISTED IN THE MANUAL OF CROSS -CONNECTION CONTROL" AS PUBLISHED BY THE UNIVERSITY OF SOUTHERN CALIFORNIA
(LATEST EDITION) USC-APPROVED ASSSEMBLIES LIST
7 BACKFLOW DEVICES SHALL BE TESTED BY AN LICENSED BACKFLOW ASSEMBLY TESTER AT START-UP AND ANNUALLY THEREAFTER. PROVIDE FIELD REPORT TO
CONSTRUCTION MANAGER.
8 WATER HYDRANT'S AND HOSE-BIBBS REQUIRE VACUUM BACKFLOW PREVENTION AND ARE SCHEDULED IN THE PLUMBING FIXTURE SCHEDULE
9 MOUNT ASSEMBLIES 12" TO 30" ABOVE FINISHED FLOOR.
10 RPBA'S & RPDA'S SHALL HAVE DRAINS VIA AIR GAP TO NEAREST FLOOR SINK
EQUIPMENT
CLASSIFICATION
EQUIPMENT ID
DESCRIPTION
LOCATION AREA/SYSTEM SERVED
STATUS
MANUFACTURER
SPECIFIC NOTES:
1. PROVIDE FLOOD CONTROL INTEGRATED SYSTEM (FCIS) TO ALARM CATASTROHIC LEAKS. PROVIDE 120V TO CONTROLLER
2. SIZED FOR 50, TOTAL FLOW. IN PARALLEL WITH SECOND RPBA.
MODEL
TYPE
SIZE
(IN)
PHYSICAL DIMENSIONS
LENGTH
(IN)
WIDTH
(IN)
HEIGHT
(IN)
PERFORMANCE
OPERATING WEIGHT
(LBS)
FLOW
(GPM)
MAX PRESSURE DROP
(PSIG)
SPECIFIC NOTES
RPBP
RPBP
2
2FL - MECHANICAL CLOSET
2-2 2FL - JANITORS CLOSET
LAB WATER SYSTEM
MAKE UP WATER SYSTEM
NEW
NEW
ZURN
ZURN
975XL2
975XL
REDUCED PRESSURE PRINCIPLE ASSEMBLY
2"
REDUCED PRESSURE PRINCIPLE ASSEMBLY I 1"
27"
18"
6"
6"
12"
9„
34
14
25
20
14
14
P-_UM* PU 4'S ED E
GENERA NOTES:
1 SEE STRUCTURAL DRAWINGS FOR SEISMIC INFORMATION
2 SEE SPECIFICATION SHEETS FOR DIMENSIONS AND ACCESS REQUIREMENTS
SPEi FIC NOTES:
DESCRIPTION
PHYSICAL DIMENSIONS
PERFORMANCE
EQUIPMENT
CLASSIFICATION
EQUIPMENT ID
LOCATION
AREA/SYSTEM
SERVED
ELEVATOR W100E2
ELEVATOR W100E2
STATUS
NEW
MANUFACTURER MODEL
BELL & GOSSETT SC0311AV
TYPE
QUANTITY
SUBMERSIBLE
MATERIALS OF
CONSTRUCTION
CAST IRON
LENGTH
(IN)
WIDTH
(IN)
HEIGHT
(IN)
6.4 12.1
OPERATING WEIGHT
(LBS)
29
NUMBER OF PUMPS
OPERATING IN
PARALLEL (#)
REDUNDANCY LEVEL
(N, N+1, ETC.)
DESIGN PUMP FLOW
(GPM)
50
DESIGN PUMP SPEED
(RPM)
3000
TOTAL HEAD
(FT W. C.)
5
QUANTITY OF
ELECTRICAL
CONNECTIONS
(#)
VOLTAGE
(V)
115
PHASE
(0)
ELECTRICAL
MOTOR HORSEPOWER ALTERNATIVE POWER !STARTER PROVIDED BY
(HP) SOURCE REQUIRED
1/3 NO I ELECTRICAL
DISCONNECT
PROVIDED BY
ELECTRICAL
SPECIFIC NOTES
PG1 9-0156
S A B Archit0cts
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
REVIEWED FOR
CODE COMPLIANCE
APPROVED
.. 7 2(?1(
L
SPACE FOR OFFICIAL CITY USE ONLY
City of Tukwila
BUILDING DIVISION
PLUMBING
SCHEDULES
RECEIVE()
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
DATE
CHECKED BY
PROJECT NUMBER
12/12/2019
DM
118108
P-003
SABArch
12/13/2019 11 :551)9Mdrs\TylerVV\Documents\1181 08-MP-CELLNETIX-v1 9_tylervvAHUUF.rvt
2" VTR
I 21 DFU
2" VTR
15 DFU
1 ri — 7 I— I-
1 I
I 1 1 1 1 I I
2" V 2" V 2" V 2" V 22" V 2'' V 2. V
13DFU I 3 DFU 13 DFU 3DFU 3DF 13 DFU 132 DFU 13 DFU 13 DFU
2" W
6 DFU
_1 J
4" W
9 DFU
ROUTE TO EXISTING
BUILDING SYSTEM
ROUTE TO EXISTING
BUILDING SYSTEM
PLUMBING SANITARY WASTE & VENT DIAGRAM
2"W 2DFU
-
2" V
2 DFU
4" W
68 DFU
—J
3 DFU
2,
21 DFU
_
2" W
3 DFU
2" W
3 DFU
CD
ROUTE TO EXISTING
BUILDING SYSTEM
1
1
2" V 2" V TV 2" V
1 3 DFU 13 DFU 13 DFU
J
2" W
3 DFU
2" W
12 DFU
2" W
3 DFU
2"
3 D
4" W
15 DFU
2"V 2DFU
WEST EAST
7
2" V I 2' V
I 3 DFU I 3 DFU
2" VTR
I 12 DFU
2" V
3 DFU
4" W
30 DFU
2" V
1 3 DFU
1
2" V
4 DFU
2" V
12 DFU
2;wp,u--
2" V
12 DFU
- ROUTE TO EXISTING
BUILDING SYSTEM
ROOF
2ND FLOOR
1ST FLOOR
- ROUTE TO EXISTING
BUILDING SYSTEM
P-020
SCALE: NTS
21 " ID i(C 8 2I "D (11C ) 2FU1
2 4" LW(
L1C
)
I 2" LV (C)
6 DFU
4"8 LDWF,( jqL
2 PLUMBING LAB WASTE & VENT DIAGRAM
1
1
2" LV (C)
1 6 DFU
22 "4 LI DVF (UC 33 "0 LDVF (IJC 33 "6 LCVF (1? 34 "2 LV D (l C)
2" LV (C) 2" LV (C) 2" LV (C)
6 DFU I 6 DFU 6 DFU
EG-SD CGBD
2" LW (C)
6 DFU
4" LW (C
30 DFU
2" LW (C)
6 DFU
4" LW (C)
36 DFU
2" LW LC)
6 DFU
4" LW (C
42
3" LVTR (C)
1SSDFU
L-
34"8`DvF(,) - - -
I 2" LV (C)
1 6 DFU
1
2" LW (CI
6 DFU
8 DFU
ROUTE LAB WASTE TO
SANITARY WASTE RISER
SEE DIAGRAM 1/P-020
I 2" LV (C)
3 DFU
1
GSD I
2" LW n
3 DFU
4" LW (C)
51 DFU
ROOF
2ND FLOOR
1ST FLOOR
P-020 SCALE: NTS
PG1 9-0156
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
REVIE,NEU r)rt
CODE COMPLIANCE
APPROVED
jAN 1 7 202b
City of Tukwila
BUILDING_DLVI SION
SPACE FOR OFFICIAL CI, USE ONLY
PLUMBING
WASTE AND
VENT
DIAGRAMS
DATE 12/12/2019
RECEIVED CHECKED BY DM
CITY OF TUKWILA PROJECT NUMBER 118108
DEC 2 0 2019
PERMIT CENTER
P-020
3 WSFU
S A B Architects
`
- -4
5
-1/2" DCW
1/2" DHW
FUTURE
GROSSING
STATION
3/4" LHW
13.5 WSFU
1 1/4" LCW
19 WSFU
3/4" LHWR
LAB WATER SYSTEM DIAGRAM
1 1/4" LHW
32 WSFU
1 1/2" LCW
32 WSFU
1 1/2" LHW
41 WSFU
6 WSFU
41 WSFU
1.5 WSFU
3/4" LCW
/ 3 WSFU
EQP171
2" DCW
P-021
SCALE: NTS
- 2ND FLOOR
---LS1/2" DCW
-1/2" DHW
BREAKROOM E237/COFFEE E212 WATER DIAGRAM
1ST FLOOR CEILING
P-021
6
P-021
SCALE: NTS
1/2" DCW-
-1/2" DHW
1/2" DCW
2ND FLOOR
1ST FLOOR CEILING
1ST FLOOR
LIBRARY/STORAGE W102 WATER DIAGRAM
SCALE: NTS
1" TW
8 WSFU
2
1-2" DCW
TEMPERED WATER SYSTEM
2" DCW
EWH
2-1
P-021
SCALE: NTS
1 WSFU 1 WSFU
1/2" DHW-
- -1/2" DCW-
2ND FLOOR
-1/2" DHW-I-,
CONNECT TO EXISTING
- -1/2" DCW-4-..- BUILDING SYSTEM
1ST FLOOR CEILING
3 COFFEE W216/MOTHERS W214 WATER DIAGRAM
P-021 SCALE: NTS
PG1 9-0156
2ND FLOOR
1ST FLOOR
RECEIVED
CITY OF TUKW!LA
DEC 20 2019
PERMIT CENTER
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.corn
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
CODE COMPLIANCE
APPROVED
JAN 7 2020
City of Tukwila
BUILDING DIVISION
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
DOMESTIC
WATER
DIAGRAMS
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
P-021
5 A B Architects
4tA rs\TylerW\Documents\118108-MP-CELLNETIX-v19_tylerwAHUUF.rvt
2 1/2" DCW-`
it
21/2" DCW (UG)
®2"WUP
03 2"WUP
(ESEW-1)
1" TW
2" W
2"WUP®
DNTOESEW,;
-2" V DN TO FIXTURE
WDN
2"WUP
®2"WU
\--10 \c) \c)
LEVEL 01 - MAIN FLOOR - PLUMBING - WEST
®2"WUP
WUP®
2" DCW
-2"V
2"W
3 2"WUP
4" W
2"WUP®
®2"WUP
4" W
®2"WUP .
4"W
SCALE: 1/8" = 1'-0"
GENERAL NOTES
A. NEW WORK SHOWN BOLD.
B. NEW HORIZONTAL WASTE PIPING BELOW 4"0 SHALL BE RUN WITH A UNIFORM SLOPE
OF NOT LESS THAT 1/4" PER FOOT.
SLOP. OF NOT LE"+ THAN 1/8" ER FOOT.
D. ALL X-RAY, SCANNING, CORE DRILLING, SAWCUTTING & EXCAVATION BY OTHERS.
KEYNOTES 0
1 REPLACE EXISTING 2" DCW PIPING WITH NEW 2 1/2" DCW PIPING.
2 CONNECT TO EXISTING 2" DCW PIPING.
3 CONNECT TO S-1.
4 CONNECT TO S-2.
5 CORROSIVE WASTE UP TO GROSSING STATION.
6 CONNECT WASTE PIPING TO EXISTING BUILDING SYSTEM.
7 CONNECT VENT PIPING TO EXISTING BUILDING SYSTEM.
8 CONNECT DCW & DHW PIPING TO EXISTING BUILDING SYSTEM.
9 PROVIDE 24"X24" ACCESS PANEL.
RECEIVED
CITY OF T UKWILA
DEC. 2 0 2019
PERMIT CENTER
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
;ODE CC`7M
APPROVE
202/
City of Tukwila
L BUILDING DIVISION
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
PLAN LEVEL 1
WEST
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
PG19-0156 P-111
5 A B Archit .ects
IX-v19_tylerwAHUUF.rvt
s\118108-MP-CE
12/13/2019 11 :55138Wers\TylerVV\Docum
1\:;410(VO
C)2" W UP --
4" W
C) 2" W UP
2" W
LEVEL 01 - MAIN FLOOR - PLUMBING - EAST
3/4" DCW
3/4" DHW
1/2" DCW UP
2" W UP
SUP
®
1/2" DH
1/2" DCW
1/2" DCW
12qw" DCW UP
1/2" DFIW UP
sil ,•!,
0 1/2" DCW UP
0 2" W UP
0 1/2" DHW UP —
1/2" DCW
1/2" DHVV
P-112,
SCALE' 1/8" = 1,0"
0 4' 8' 16'
GENERAL NOTES
A. NEW WORK SHOWN BOLD.
B. NEW HORIZONTAL WASTE PIPING BELOW 4"0 SHALL BE RUN WITH A UNIFORM SLOPE
OF NOT LESS THAT 1/4" PER FOOT.
SLOP OF NOT LE= THAN 1/8" R FOOT.
D. ALL X-RAY, SCANNING, CORE DRILLING, SAWCUTTING & EXCAVATION BY OTHERS.
KEYNOTES 0
1 CONNECT TO S-1.
2 CONNECT TO S-2.
3 CONNECT TO DW-1.
ED
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
I CODE, CC,',-IPLI„..A.NCE
A P P RovE
City of Tukwila
BUILDING DIVISION
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
PLAN LEVEL 1
EAST
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
PERMIT CENTER
PG1 9-0156 P-1 1 2
5 A B Architects
2" V DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE ---
2" V DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
2" V DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
1" TW DN
1 — —
1" LHW
1 1/2" LCW
--- 2" V DN TO FIXTURE
W DN
— — —
\ 1 1/4" LHW
L-- 1 1/2" LCW
DN TO FIXTURE
DN TO FIXTURE
2" V UP TO VTR
v--- 1" TW
2, DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
2" V UP TO VTR
— 12" LV (C
1 1/4" LCW-\
1
3" LV (C)
3" LV (C) UP TO VTR --
2" LV
1" TW DN TO ESEW
2" V DN TO FIXTURE
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
1/2" LCW DN TO GROSSING STATION
1/2" LHW DN TO GROSSING STATION
2" LV (C) DN TO GROSSING STATION
2" LW (C) DN
- 1" TVV DN TO ESEW
„
(E-Si1--N21) '\-• 2" V
1/4" LCW
C) CD CD CD CD
2" V DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
LCW
1/2" LCW TO EQP065 & 081
2" V DN TO FIXTURE
2" W DN
1/2 " LHW DN TO FIXTURE
3/4" LCW DN, 1/2 LCW TO FIXTURE
3" LV (C)
3/4" LHW
LEVEL 02 - UPPER FLOOR - PLUMBING - WEST
2" LV (C)
3/4" LHW
2" V
Cl>" 1/2" LHW
-1/2" LCW
1/2" LCW DN TO EQP064
2" V DN TO FIXTURE
r 2" W DN
3/4" LHW
2" LV (C)
C7.) EG 16-s)
1" DCW MAKE UP
WATER UP TO
HEAT RECOVERY
SYSTEM
3/4" LHWR
TO GROSSING STATION (TYP. 7)
2" LW(C) DN TO FIRST FLOOR CEILING (TYP. 7)
-- 2" LW (C) (TYP. 14)
1/2" LCW DN TO GROSSING STATION (TYP. 14)
1/2" LHW DN TO GROSSING STATION (TYP. 14)
2" V DN TO FIXTURE
2" V DN TO FIXTURE
DN F 1/2" LCW DN TO FIXTURE / 2" V DN TO FIXTURE
2" W DN
WON TO FIXTURE i/ 1/2" LHW DN TO FIXTURE 2" W DN
1/2" LCW DN TO FIXTURE
DN TO FIXTURE 1/2" LHW DN TO FIXTURE
2" V
1/2" LHW
1/2" LCW
1" NPCW
TW
1 1/4" LHW
1 1/2" LCW
1" TW DN TO ESEW
4" LCW
1/2" LHW
1 1/4" TW
- 1 1/2" LHW
1 1/2" LCW
3/4" LHW
LCW
1" NPCW
3/4" LHWR
2" V DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
2" V
3/4" LCW
t 2" V DN TO FIX RE
2" W DN
4'
8'
1" TW
16'
P-121 SCALE: 1/8" = 1'-0"
GENERAL NOTES
A. NEW VVORK SHOWN BOLD.
B. NEW HORIZONTAL WASTE PIPING BELOW 4.0 SHALL BE RUN WITH A UNIFORM SLOPE
OF NOT LESS THAT 1/4" PER FOOT.
SLOP OF NOT LE" THAN 1/8" ER FOOT.
D. ALL X-RAY, SCANNING, CORE DRILLING, SAWCUTTING & EXCAVATION BY OTHERS.
KEYNOTES 0
CONNECT VENT PIPING TO EXISTING BUILDING SYSTEM.
P AND
2"LC " LHW TURE ING ST
3 CA " L (C) & 2" (C FOR F R GROSS G ATION.
4 PROVIDE VALVE AND 1/2" CONNECTION TO MILLIPORE SYSTEM.
5 ROUTE WATER AND WASTE PIPING IN CASE WORK. INDIRECTLY CONNECT EQUIPMENT
WASTE TO S-1 WASTE. ROUTING THROUGH CASE WORK TO BE FIELD CORRDINATED.
PG19 0156
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
CONSTRUCTION
DRAWING SET
CODE
lAj 7 20
City 0/ Tukwiia
FBUILDiN-G civrsioNli —
Si3Aut roi-t Ln-rfutAt-Cfrf-ttSE ONLY
PLUMBING
PLAN LEVEL 2
WEST
DATE
CHECKED BY
PROJECT NUMBER
12/12/2019
DM
118108
P 121
SABArchitects
3/2019 11:55001AMrs\TylerVV\Documents\118108-MP-CELLNETIX-v19_tylerwAHUUF.rvt
2" V DN TO FIXTURE
2" W DN
1/2" LCW DN TO FIXTURE
1/2" LHW DN TO FIXTURE
-
\- 3/4" LCW
1" TW
2VDNTOF/XIJRE
2" W DN
1 2" V DN TO FIXTURE
2" W DN
1/2" LCW ON TO FIXTURE
rcr 1/2" LHW DN TO FIXTURE
1/2" LCW
1/2" LHW
2" V UP TO VTR
2" V
(ESEWit)
1" TW DN TO ESEW
V DN TO FIXTURE
1
1/2" LCW DN TO FIXTURE
LHW DN TO FIXTURE
2" W DN
LEVEL 02 - UPPER FLOOR - PLUMBING - EAST
2" V DN TO FIXTURE
2"WDN
TV
1/2" DHW DN
1/2" DCW DN
2: VDDNNTO FIXTURE 2w
P-122 SCALE: 1 /8', 1.-0"
16'
GENERAL NOTES
A. NEW WORK SHOWN BOLD.
B. NEW HORIZONTAL WASTE PIPING BELOW IVO SHALL BE RUN WITH A UNIFORM SLOPE
OF NOT LESS THAT 1/4" PER FOOT,
SLOP: OF NOT LE' THAN 1/8" ER FOOT.
D. ALL X-RAY, SCANNING, CORE DRILLING, SAWCUTTING & EXCAVATION BY OTHERS.
KEYNOTES 0
1 CONNECT 1/2" DCW & 1/2" DHW FROM BELOW TO FIXTURE.
2 CONNECT VENT PIPING TO EXISTING BUILDING SYSTEM.
3 PROVIDE VALVE AND 1/2" CONNECTION TO MILLIPORE SYSTEM.
PG19-0156
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
vvww.sabarch.com
CELLNETIX
FACILITY
RELOCATION
,416, 1,461
CONSTRUCTION
DRAWING SET
L330ycf TOW, ia
SPPg99TOWN6f9T,I,-, O
NLY
PLUMBING
PLAN LEVEL 2
EAST
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
P-122
S A B Architects
LEVEL 01 - BELOW GRADE PLUMBING PLAN EB
P-400 SCALE: 1/4" = 1'-0"
ETI X-v 19_tyl e rwAH U U F. rvt
118108-MP-CE
12/ 13/2 019 11: 55 i33, l4 rs\Ty l e r1M Doc u m e
8'
mum
GENERAL NOTES
A. NEW WORK SHOWN BOLD.
B. NEW HORIZONTAL WASTE PIPING BELOW 4"0 SHALL BE RUN WITH A UNIFORM SLOPE
OF NOT LESS THAT 1/4" PER FOOT.
We ...G,,,q�.�.. :.'A
SLOP, OF NOT LETHAN 1/8" ' ER FOOT.
D. ALL X-RAY, SCANNING, CORE DRILLING, SAWCUTTING & EXCAVATION BY OTHERS.
1 CONNECT WASTE PIPING TO EXISTING BUILDING SYSTEM.
2 ROUTE SUMP PUMP DISCHARGE TO FUNNEL DRAIN IN FIRE PUMP ROOM. PROVIDE
CODE REQUIRED AIR GAP.
3 SUMP PUMP LOCATION TO BE FIELD COORDINATED WITH FINAL ELEVATOR SUMP
LOCATION.
4 RROVIDE AIR GAP FITTING AND PIPE RELIEF TO MOP SINK.
5 ROUTE WATER HEATER RELIEF TO EXISTING MOP SINK.
6 TIE LAB WASTE RISER INTO SANITARY RISER JUST ABOVE SLAB.
TMV
2-2
1 1/4" DCWj
RPBP
2-1
4 JAN CLOSET W202 ENLARGED PLANED
P-400 SCALE 3/4" = 1'-0" 0 1' 2' 3'
LEVEL" 02
15'-0
3 JAN CLOSET W202 NORTH WALL
P-400 SCALE: NTS
2
JAN CLOSET W202 SOUTH WALL
P-400
SCALE: NTS
UPPER FLOOR /1
15'-0°
PG1 9-0156
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
yak13 2-0'1`,1
CONSTRUCTION
DRAWING SET
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
ENLARGED
PLANS &
SECTION
VIEWS
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
P-400
S A B Architects
7
112" LCW
112LHW
2"LW(C)
GROSSING STATION
- 1/2" LCW TO DISTRIBUTION PIPING
2" LV (C) TO DISTRIBUTION PIPING
1/2" LHW TO DISTRIBUTION PIPING
GROSSING STATION
1/2" LCW
1/2LHW
2"LW(C)
2"LW(C)DN
GROSSING STATION DETAIL - PLUMBING
P-500 SCALE: 3/8" =
NETIX-v19_tylerwAHUUF.rvt
12/13/201911:55:0A9 rs\TylerW\Documents\118108-MP-CE
AIR GAP FITTING W/
FULL SIZE
DISCHARGE
FLOOR SIZE DRAIN
TO FLOOR DRAIN,
MOP RECEPTOR,
OR MOP SINK -
RECESSED FLOOR
DRAIN
f- TO EQUIPMENT
OR SYSTEM
STRAINER T
FROM DCW
/ BUILDING SYSTEM
18" MIN
60" MAX AFF
HOSE BIBB W/ NON -REMOVABLE
THREADED HOSE CONNECTION
VACUUM BREAKER WATTS MODEL
8A OR EQUAL
4 REDUCED PRESSURE BACKFLOW PREVENTER DETAIL
P-500 SCALE: NTS
5
P-500
REDUCED PRESSURE
PRINCIPAL BACK FLOW
PREVENTION DEVICE
FROM
MUNICIPAL CW
SYSTEM
INDIRECT WASTE RECEPTOR
W/ MANUFACTURER LISTED
AIR GAP FITTING ROUTE TO
NEAREST FLOOR DRAIN
AUTOMATIC PRESSURE
RELIEF VALVE SET AT 75 PSI
P/T PORT
T (TYP)
PRESSURE GAUGE 4"
DIA. 0-100 PSI (TYP.)
1/4"MxF NEEDLE
VALVE (TYP.)
AUTOMATIC PRESSURE
RELIEF VALVE SET AT 40 PSI
O
\__UNION (TYP.)
GLOBE VALVE
(TYP.) NORMALLY
CLOSED
1„
PRV WITH
INTERNAL STRAINER
TSET @ 25 PSI
FULL PORT BALL VALVE WITH
HOSE ADAPTER AND CAP (TYP)
HVAC SYSTEM MAKE-UP WATER DETAIL
SCALE: 12" =
FINISH FLOOR SLAB
ROUGH FLOOR SLAB -----
DRAIN STRAINER FLUSH
WITH FLOOR
FINISHED FLOOR VENEER
`~- TRAP PRIMER CONNECTION (WHEN SPECIFIED)
NO -HUB OR NEO-LOC CONNECTION
SEE PLAN FOR SIZE AND ROUTING
6 FLOOR DRAIN / SINK DETAIL
P-500 SCALE: NTS
T
6 TO
SYSTEM
CHECK VALVE
SLIP JOINT NUT
AND SEAL
P-TRAP
NOTES:
WALL TUBE AND
ESCUTCHEON -
FEMALE NPT OUTLET
PRIMER TUBE
GROUND JOINT
CONNECTION
FINISHED WALL -
WALL ESCUTCHEON
COMPRESSION
FITTING
--1 1/2" WASTE
3"
3/4" 1/2" PRIMER TUBE
RECOMMENDED ROUGH -IN
1. SEE PLANS OR RISER FOR PIPE SIZES.
2.INVERT OF CONNECTION LOCATED 1/8" ABOVE STATIC WATER LEVEL ENABLING "OVERFLOW" INTO PRIMER TUBE
WHEN TEMPORARY HEAD OF WATER IS CREATED.
TRAP PRIMER DETAIL
P-500 SCALE: NTS
2
"CLOSE NIPPLE"
CW SUPPLY
1. FLUSH LINE PRIOR TO INSTALLATION
2. USE RIBBON PIPE SEAL -ONLY
3. INSTALL WRENCH ON EXTREME TOP OF HEX
4. INSTALL UNIT PLUMB
5. EFFECTIVE OPERATING RANGE 35 TO 75 PSIG.
6. FAILURE TO FOLLOW THESE INSTRUCTIONS
WILL MAKE NULL AND VOID ANY PRODUCT
WARRANTY
7. NOTE: PREFERRED TYPE OF TRAP PRIMER
SHALL BE J R SMITH PRIME-EZE TRAPS OR
FLUSHOMETER VALVE TAILPIECE PRIMERS (AS
APPROVED PER CODE).
12" MIN
"INVERTED TRAP"
180° BEND
1/2" BALL VALVE
MIFAB MODEL M-500
SERIES
DISTRIBUTION BOX
DISTRIBUTION PIPE
TO FLOOR DRAIN
FINISH FLOOR
TRAP PRIMER DETAIL B
P-500
SCALE: NTS
SEE FLOOR PLAN FOR
PIPE SIZE
FIRE -STOPPING AT ALL
RATED FLOORS
CORE DRILL EXISTING FLOOR
NOTES:
1. UTILIZE THIS DETAIL FOR PIPE RISERS OF 3 FLOORS OR LESS
RISER CLAMP ANVIL FIG 261
CAULK SEAL WHERE INSULATION
DOES NOT OCCUR
CORE DRILL FLOOR SIZED TO
PROVIDE 1/4" ANNULAR SPACE X-
RAY ANY POST -TENSION DECKS
3 PIPE FLOOR PENETRATION DETAIL
P-500 SCALE: NTS
PG1 9-0156
RECEIVED
CITY OF TUKWILA
DEC 2 0 2019
PERMIT CENTER
2 Nickerson Street Suite 200
Seattle, WA 98109
206 957 6400
www.sabarch.com
CELLNETIX
FACILITY
RELOCATION
l y L0'7
CONSTRUCTION
DRAWING SET
City cf i Ukwiic`
L LBUiI_DNG
SPACE FOR OFFICIAL CITY USE ONLY
PLUMBING
DETAILS
DATE 12/12/2019
CHECKED BY DM
PROJECT NUMBER 118108
P-500